Home
0H9060 RevB.indd - Northern Tool + Equipment
Contents
1. 1500 FSUMP P mp aa rae coin ca See 800 to 1050 T Operation Table Saw A0 Dardos 1750 10 2000 RIED RC ERI 200 to 500 da DAP RIT OPES 1000 to 1650 Weed Trimmer 500 Allow 3 times the listed watts for starting these devices 2 1 BEFORE STARTING THE GENERATOR Prior to operating the generator engine oil and gasoline will need to be added as follows 2 7 1 ADDING ENGINE OIL All oil should meet minimum American Petroleum Institute API Service Class SJ SL or better Use no special additives Select the oil s viscosity grade according to the expected operating temperature also see chart Above 40 use SAE 30 Below 40 F and down to 10 F use 10W 30 Below 10 F use synthetic 5W 30 10w 30 F 20 10 0 10 20 32 40 60 80 100 Temperature Range of Expected Use CAUTION Any attempt to crank or start the engine before it has been properly serviced with the recommended oil may result in an engine failure Place generator on a level surface Clean area around oil fill and remove oil fill cap Slowly fill engine with oil until the dipstick reads full Stop filling occasionally to check oil level Install dipstick and finger tighten securely e Check engine oil level before starting each time thereafter 2 7 2 ADDING GASOLINE A DANGER
2. Monof sico Las potencias y corrientes m ximas est n sujetas a y limitadas por factores tales como contenido en BTUs del combustible altitud condiciones del motor etc La potencia m xima disminuye alrededor del 3 5 por cada 1000 pies sobre el nivel del mar y tambi n disminuir alrededor del 1 por cada 6 C 10 F por encima de los 16 C 60 F de temperatura ambiente 9 2 2 ESPECIFICACIONES DEL MOTOR Desplazamie ceret te nete eee 420cc Tipo de Dula 5 o ori mme ems Champion N9YC o NHSP LDF7TC Espaciamiento de la 0 030 pulgadas o 0 76 mm Capacidad de gasolina sene 8 galones americanos Tipo de Ver la cartilla en la secci n Agregar aceite de motor Capacidad de aceite 2 ore oni nee tre een 1 0 Litro 1 06 Qts Tiempo de funcionamiento 50 de 12 horas Certificado para emisi n de Clase II 3 2 3 INFORMACI N DE EMISIONES La agencia de protecci n ambiental EPA requiere que este generador cumpla con los est ndares de emisi n en el escape El motor usado en este generador est certificado para cumplir los niveles de emisi n de EPA aplicables Es importante seguir las especificaciones en la secci n de mantenimiento proporcionadas en este manual para asegurar que su motor cumple con los est ndares de emisi n aplicables por la
3. Les heures suppl mentaires le travail de jour f ri ou en urgence de la main d uvre Les batteries de d marrage fusibles ampoules et fluides du moteur LA PR SENTE GARANTIE REMPLACE TOUTES LES AUTRES GARANTIES IMPLICITES OU EXPLICITES EN PARTICULIER GENERAC N MET AUCUNE GARANTIE DE CONFORMIT OU D USAGE POUR UN OBJECTIF PARTICULIER Toute garantie implicite autoris e par la loi doit tre limit e en dur e conform ment aux conditions de garantie explicite stipul es dans la pr sente Certains tats ne permettent pas de poser une limite la dur e de la garantie implicite la limite susmentionn e ne s applique donc pas ces derniers GENERAC NE SERA RESPONSABLE QUE DE LA R PARATION OU DU REMPLACEMENT DE LA OU DES 5 TEL QUE SUSMENTIONNE EN AUCUN CAS GENERAC NE POURRA RESPONSABLE DE TOUT DOMMAGE ACCESSOIRE OU IMPORTANT SI CE DOMMAGE D COULE DIRECTEMENT D UNE N GLIGENCE DE GENERAC Certains tats ne permettent pas d exclure ou de poser une limite aux dommages accessoires ou importants la limite susmentionn e s applique donc pas ces derniers La pr sente garantie vous conf re des droits juridiques sp cifiques Votre tat vous conf re galement d autres droits GENERAC POWER SYSTEMS INC 0 BOX 8 Waukesha WI 53187 T l 888 GENERAC 436 3722 Fax 262 544 4851 Pour localiser le d positaire le plus proche visitez notre site Internet www generac com R f r
4. 1 Couper les attaches de c ble fixant les c bles de batterie et retirez les couvercles rouges des bornes de la batterie 2 Brancher d abord le c ble rouge la borne positive de la batterie l aide du boulon du contre crou et de l crou fournis 3 Brancher le cable noir la borne n gative de la batterie l aide du boulon du contre crou et de l crou fournis 4 S assurer que tous les branchements sont fixes Faire glisser les enveloppes de caoutchouc sur les bornes et le mat riel de branchement REMARQUE S il est impossible de d marrer le moteur l aide de la batterie brancher le chargeur de 12 V inclus dans la boite d accessoires voir la section Chargement de la batterie pour plus d informations 2 1 BIEN CONNA TRE LE G N RATEUR Merci de lire le Manuel d entretien et les R gles de s curit avant de faire fonctionner ce g n rateur Comparer le g n rateur aux Sch mas 2 4 pour vous familiariser avec les emplacements des divers contr les et r glages Conserver ce manuel pour m moire 1 Prise double DDFT 120 V c a 20 A Fournit une alimentation lectrique pour le fonctionnement d un clairage lectrique d appareils d outils et de charges de moteur 120 V c a 20 A monophas 60 Hz 2 Prise verrouillage 120 240 V c a 30 A Fournit une alimentation lectrique pour le fonctionnement d un clairage lectrique d appareils d outils et de charges de
5. Compare the generator to Figures 2 through 4 to become familiarized with the locations of various controls and adjustments Save this manual for future reference 1 120 Volt AC 20 Amp Duplex Receptacle Supplies electrical power for the operation of 120 Volt AC 20 Amp single phase 60 Hz electrical lighting appliance tool and motor loads 2 120 240 Volt AC 30 Amp Locking Receptacle Supplies electrical power for the operation of 120 and or 240 Volt AC 30 Amp single phase 60 Hz electrical lighting appliance tool and motor loads 3 Circuit Breakers AC Each receptacle is provided with a push to reset circuit breaker to protect the generator against electrical overload 4 Oil Drain Use to drain engine oil 5 Air Filter Filters intake air as it is drawn into the engine 6 Choke Knob Used when starting cold engine Figure 3 Generator Controls 7 Fuel Tank See generator Specifications for tank capacity 8 Grounding Lug Ground the generator to an approved earth ground here See Grounding the Generator for details 9 Run Stop Switch Controls the operation of the generator pull start models 9A Start Switch Used to start engine from the starter motor electric start models only 10 Muffler Quiets the engine Figure 2 Control Panel 11 Handle Pivot and retract for storage Press the spring loaded button to move handles
6. hunts or falters 14 1 Circuit breaker is open 2 Poor connection or defective cord set 3 Connected device is bad 4 Fault in generator 1 Short circuit in a connected load 2 Generator is overloaded 3 Engine speed is too slow 4 Shorted generator circuit Fuel Shut off is OFF Dirty air filter Out of gasoline Stale gasoline Spark plug wire not connected to spark plug Bad spark plug Water in gasoline Over choking 9 Low oil level 10 Excessive rich fuel mixture 11 Intake valve stuck open or closed 12 Engine has lost compression 1 2 3 4 5 6 7 8 1 Out of gasoline 2 Low oil level 3 Fault in engine 1 Load is too high 2 Dirty air filter 3 Engine needs to be serviced 1 Choke is opened too soon 2 Carburetor is running too rich or too lean CORRECTION 1 Reset circuit breaker 2 Check and repair 3 Connect another device that is in good condition 4 Contact Authorized Service Facility 1 Disconnect shorted electrical load 2 See Don t Overload the Generator 3 Contact Authorized Service Facility 4 Contact Authorized Service Facility Turn Fuel Shut off to ON Clean or replace air filter Fill fuel tank Drain fuel tank and fill with fresh fuel Connect wire to spark plug Replace spark plug Drain fuel tank fill with fresh fuel Put choke knob to No Choke position 9 Fill crankcase to pro
7. Energiza el arrancador el ctrico s lo arranque el ctrico Medidor de horas Mide las horas de operaci n Operaci n Figura 3 Controles del generador 25 Operaci n 2 2 MEDIDOR DE HORAS El medidor de horas mide el tiempo de operaci n para seguir los mantenimientos programados Habr un mensaje de CHG OIL cada 100 horas El mensaje destellar una hora antes y una hora despu s de cada intervalo de 100 horas proporcionando una ventana de dos horas para realizar el servicio Este mensaje realmente empezar a destellar a las 99 horas y se deshabilitar a las 101 horas proporcionando una ventana de dos horas para realizar el servicio Cada 200 horas el icono SVC en la esquina inferior izquierda de la pantalla destellar El mensaje destellar una hora antes y una hora despu s de cada intervalo de 200 horas proporcionando una ventana de dos horas para realizar el servicio Cuando el medidor de horas est en el modo de alerta de destello Flash Alert el mensaje de mantenimiento siempre alternara con el tiempo transcurrido en horas y d cimos Las horas destellar n cuatro veces luego alternar con los mensajes de mantenimiento cuatro veces hasta que el medidor se reinicia 100 hrs CHG OIL Intervalo cambio de aceite c 100 hrs 2 3 JUEGO DE CUERDAS Y CONECTORES 2 3 1 RECEPT CULO DUPLEX DE 120 VAC 20 AMP Esta es una toma de 120 voltios protegida contra sobrecarga por un interr
8. Indice de 23 3 22 Especificaciones del motor 30 3 2 3 Informaci n sobre las emisiones 31 Informaci n 24 3 3 Recomendaciones generales ss 31 lo Desempaque 5 iiis 24 3 31 Mantenimiento del generador 31 1 1 1 Caja de 24 3 3 2 Limpieza del generador 31 1 2 Ensamble oia 24 3 8 3 Mantenimiento del 31 1 2 1 Ensamblaje del kit de accesorios 24 3 3 4 Revisi n del nivel de aceite 31 1 2 2 Conexi n del cable de la bater a arranque 3 3 5 Cambio de 31 el ctrico 24 3 3 6 Reemplazo de la 32 3 3 7 Reemplazo de la 32 AA 24 vU A O Me ANG e 32 2 1 Conozca el 24 3 5 Almacenamiento a largo plazo Nd CLEA 32 2 2 Medidor de 2 26 3 6 Otros consejos para almacenamiento 33 2 3 Juego de cables y 26 22 2
9. LA REPARACI N 0 REEMPLAZO DE LAS PARTES TAL COMO SE ESPECIFICA ARRIBA EN NING N CASO GENERAC SER RESPONSABLE POR CUALQUIER DANO INCIDENTAL O CONSECUENCIAL A N SI TALES DANOS SEAN UN RESULTADO DIRECTO DE UNA NEGLIGENCIA DE GENERAC Algunos estados no permiten la exclusi n o limitaci n de da os accidentales o resultantes de modo que la limitaci n mencionadas m s arriba podr an no aplicarse a usted Esta garant a le da a usted derechos legales espec ficos Usted tambi n tiene otros derechos dependiendo del Estado GENERAC POWER SYSTEMS INC PO BOX 8 Waukesha WI 53187 Tel 888 GENERAC 436 3722 Fax 262 544 4851 Para ubicar al concesionario autorizado m s cercano visite nuestro sitio web www generac com Parte No 0H8902 Revisi n 05 19 10 Manual Parte No 0H9060 Rev B 08 20 10 Impreso en China GENERAC MOD LES 005942 0 005943 0 entretien Manuel rie GP de 7 500 watts G n rateur portable s 2 ANS www generac com 1 888 436 3722 Table des mati res 1 0 41 Lire attentivement ce manuel 41 R gles de s curit 41 Index des noriTles enne 43 Informations g n rales 44 A 44 1 1 1 Boite d accessoires 44 1 2 Montage cene eme e o OR ed 44 1 2 1 Montag
10. es Tous les COMPOSANTS REMARQUE Aux fins de la pr sente garantie utilisation du consommateur d signe une utilisation m nag re personnelle ou r cr ative de la part de l acqu reur d origine La pr sente garantie ne s applique pas aux unit s utilis es pour de l nergie primaire au lieu du r seau lorsque le r seau lectrique principal est pr sent ou n existe normalement pas Une fois que le g n rateur a t utilis de mani re commerciale ou locative il sera consid r par la suite comme un g n rateur utilisation non personnelle dans le cadre de la pr sente garantie Toutes les indemnit s de garantie sont soumises aux conditions d finies dans le manuel des politiques de Generac LA PR SENTE GARANTIE NE S APPLIQUE PAS AUX L MENTS SUIVANTS Les g n rateurs portables construits par Generac avant juin 2010 Les g n rateurs portables Generac utilisant des pi ces de rechange ne provenant pas de Generac Les co ts de maintenance et des modifications normales Les d faillances entrain es par de l essence ou de l huile contamin e ou par l utilisation de niveaux d huile non appropri s Les r parations ou diagnostics r alis s par des d positaires non agr s par Generac et non autoris s par crit par Generac Power Systems Les d faillances dues sans s y limiter l usure normale des accidents mauvaises utilisations usages abusifs n gligence ou utilisation inadapt e Comme po
11. goma como se muestra Deslice los tacos del parachoques de goma a trav s de la pata del marco luego instale las contratuercas de cierre Deslice los pernos de cabeza hexagonal a trav s de los agujeros del riel del marco Deslice el pie del marco en los tornillos de cabeza hexagonal y luego instale las contratuercas de cierre 3 Consulte la figura 1 e instale el manubrio como se muestra Deslice los pernos largos a trav s del soporte del manubrio y del manubrio y luego instale los pernos hexagonales 24 Figura 1 Ensamble de la rueda y el manubrio PERNO M8 LARGO TUERCA BELLOTA M8 A lu PERNO M8 CORTO X 2 PASADOR 17 EJEX2 RUEDA X 2 h ARANDELA PLANA DE 1 2 X 2 PATA DEL MARCO CLAVUA X2 UNIDAD DE MANUBRIO PATA DE GOMA X 2 TUERCA M8X4 1 2 2 CONEXI N DEL CABLE DE BATER A ARRANQUE ELECTRICO SOLAMENTE La unidad ha sido enviada deliberadamente con los cables de la bater a desconectados Para conectar la bater a ver los detalles de la conexi n en la figura 13 1 Corte los amarres del cable que aseguran los cables de la bater a y retire las cubiertas rojas de los terminales de la bater a 2 Primero conecte el cable rojo al terminal positivo de la bater a con el perno arandela de cierre y tuerca suministrados 3 Conecte el cable negro al terminal negativo de la bater a con el perno arandela de cierre y tuerca suministrados 4 Aseg rese de que to
12. 12 Gas Cap Fuel fill location 13 Fuel Gauge Shows fuel level in tank 14 Oil Fill Add oil here 15 Recoil Starter Use to start engine manually 16 Fuel Shut Off Valve between fuel tank and carburetor 17 Battery Charger Input This receptacle allows the capability to recharge the 12 volt DC storage battery provided with the 12 Volt Adaptor Plug Charger which is included in the Accessory Box Located behind the battery charger input is a 1 50 Amp in line fuse which is inside the control panel to protect the battery electric start models only 18 Battery Powers the electric starter electric start models only 19 Hourmeter Tracks hours of operation Operation 2 2 HOURMETER The Hourmeter tracks hours of operation for scheduled maintenance There will be CHG OIL message every 100 hours message will flash one hour before and one hour after each 100 hour interval providing a two hour window to perform service This message will actually begin flashing at 99 hours and disable itself at 101 hours again providing a two hour window to perform the service Every 200 hours the SVC icon on the lower left hand corner of the display will flash The message will flash one hour before and one hour after each 200 hour interval providing a two hour window to perform service When the hour meter in the Flash Alert mode the maintenance message will always alternate with elapsed t
13. 72 AJOUT DE L ESSENCE Ne jamais remplir le r servoir d essence l int rieur Eviter de renverser de l essence sur un moteur chaud Laisser le moteur compl tement refroidir avant d ajouter du carburant Ne jamais remplir le r servoir d essence lorsque le moteur fonctionne ou est chaud NE PAS allumer une cigarette ni fumer lors du remplissage du r servoir d essence L essence est extr mement INFLAMMABLE et ses vapeurs sont EXPLOSIVES f Ne pas trop remplir le r servoir d essence Toujours laisser de la place pour l expansion du carburant En cas de suremplissage du r servoir le carburant peut d border sur un moteur chaud et entra ner un incendie ou une explosion Nettoyer imm diatement toute claboussure de carburant 48 Utiliser de l essence SANS PLOMB r guli re avec le moteur du g n rateur Ne pas utiliser de supercarburant Ne pas m langer l huile avec l essence Nettoyer l espace autour du bouchon de l orifice de remplissage d essence retirer le bouchon Ajouter lentement de l essence r guli re sans plomb dans le r servoir d essence Remplir jusqu au fond du filtre tamis Faire attention de ne pas trop remplir Sch ma 8 Mettrele bouchon du r servoir d essence et nettoyer toute claboussure d essence IMPORTANT est important d emp cher la formation de d p ts de gomme dans les pi ces du circuit de carburant telles que le carburateur le tuyau pour combustible ou le r servo
14. D 7 amp D gt 10 Mezcla de combustible demasiado rica 11 V lvula de entrada atascada 0 cerrada 12 El motor ha perdido compresi n 1 Falta gasolina 2 Nivel de aceite bajo 3 Falla en el motor 1 La carga es demasiado alta 2 Filtro de aire sucio 3 El motor necesita servicio 1 El choke est abierto demasiado pronto 2 El carburador est funcionando muy rico o muy ralo CORRECCI N Reinicie el interruptor de circuito Revise y repare Conecte otro dispositivo que est en buenas condiciones Contacte a un servicio autorizado 1 Desconecte la carga el ctrica en corto 2 Vea No sobrecargue el generador 3 Contacte a un servicio autorizado 4 Contacte a un servicio autorizado Gire el cierre de combustible a ON Limpie o reemplace el filtro de aire Llene el tanque de combustible Drene y llene el tanque de combustible con gasolina fresca 5 Conecte el cable a la buj a Reemplace la buj a Drene y llene el tanque de combustible con gasolina fresca Coloque la palanca de choke en posici n No Choke Llene el c rter en el nivel apropiado 10 Contacte a un servicio autorizado 11 Contacte a un servicio autorizado 12 Contacte a un servicio autorizado 1 Llene el tanque de combustible 2 Llene el c rter en el nivel apropiado 3 Contacte a un servicio autorizado 1 Reduzca la carga Vea No sobrecargue el generador 2 Limpie o
15. N RATEUR Avant de faire fonctionner le g n rateur de l huile de moteur et de l essence devront tre ajout s de la fa on suivante 2 7 1 AJOUT DE L HUILE DE MOTEUR Toute huile doit respecter la cat gorie de service minimale SJ SL ou mieux de l American Petroleum Institute API Institut am ricain du p trole N utiliser aucun additif sp cial S lectionner le degr de viscosit d huile selon la temp rature d exploitation se reporter galement au tableau e Au dessus de 40 F utiliser le SAE 30 En dessous de 40 F et jusqu 10 F utiliser le 10W 30 En dessous de 10 F utiliser le 5W 30 synth tique 10W 30 F 20 10 0 10 20 32 40 60 80 100 30 20 10 0 10 20 30 40 Gamme de temp rature d utilisation anticip e ATTENTION Toute tentative de faire tourner ou de d marrer le moteur avant qu il ait t correctement entretenu avec l huile recommand e peut entra ner une panne du moteur Installer le g n rateur sur une surface de niveau Nettoyer l espace autour de l orifice de remplissage d huile et retirer le bouchon Remplir lentement le moteur avec de l huile jusqu ce que la jauge d huile lise plein Interrompre r guli rement le remplissage pour v rifier le niveau d huile Installer la jauge d huile et la serrer fermement au doigt V rifier le niveau d huile de moteur avant le d marrage chaque fois par la suite 2
16. Never fill fuel tank indoors Avoid spilling gasoline on hot engine Allow engine to cool entirely before adding fuel Never fill fuel tank when engine is running or hot DO NOT light a cigarette or smoke when filling the fuel tank Gasoline is highly flammable and its vapors are explosive Do not overfill the fuel tank Always leave room EX for fuel expansion If the fuel tank is overfilled fuel can over flow onto a hot engine and cause fire or an explosion Wipe up any spilled fuel immediately Use regular UNLEADED gasoline with the generator engine Do not use premium gasoline Do not mix oil with gasoline Clean area around fuel fill cap remove cap Slowly add unleaded regular gasoline to fuel tank Fill to bottom of screen filter Be careful not to overfill Figure 8 e Install fuel and wipe up spilled gasoline IMPORTANT It is important to prevent gum deposits from forming in fuel system parts such as the carburetor fuel hose or tank during storage Alcohol blended fuels called gasohol ethanol or methanol can attract moisture which leads to separation and formation of acids during storage Acidic gas can damage the fuel system of an engine while in storage To avoid engine problems the fuel system should be emptied before storage of 30 days or longer See the Storage section Never use engine or carburetor cleaner products in the fuel tank as permanent damage may occur Figure 8 Fuel Tank Fuel Ta
17. THE REPAIR OR REPLACEMENT OF PART S AS STATED ABOVE IN NO EVENT SHALL GENERAC BE LIABLE FOR ANY INCIDENTAL OR CONSEQUENTIAL DAMAGES EVEN IF SUCH DAMAGES ARE A DIRECT RESULT OF GENERAC S NEGLIGENCE Some states do not allow the exclusion or limitation of incidental or consequential damages so the above limitation may not apply to you This warranty gives you specific legal rights You also have other rights from state to state GENERAC POWER SYSTEMS INC BOX 8 Waukesha WI 53187 Ph 888 GENERAC 436 3722 Fax 262 544 4851 To locate the nearest Authorized Dealer visit our website www generac com Part No 0H8902 Revision A 05 19 10 Manual Part No 0 9060 Rev B 08 20 10 Printed in China 10 GENERAC tar tiles serie GP de 7 500 vatios 005943 0 Manual del propie MODELOS 005942 0 Generadores port 9 NB T N S A SS 5 A GARANT A LIMITADA www generac com 1 888 436 3722 Tabla de contenidos A 21 30 Lea este manual completamente 21 3 1 Cronograma de 30 3 2 Especificaciones del 1 30 Reglas de 21 3 2 1 Especificaciones del 30
18. abajo puede usarse como gu a para la operaci n de este equipo Siempre consulte la revisi n m s reciente aplicable para el est ndar listado 1 No 70 NFPA HANDBOOK OF NATIONAL ELECTRIC CODE 2 Article X NATIONAL BUILDING CODE disponible en la American Insurance Association 85 John Street New York N Y 10038 3 AGRICULTURAL WIRING HANDBOOK disponible en la Food and Energy Council 909 University Avenue Columbia MO 65201 4 ASAE EP 3634 INSTALLATION AND MAINTENANCE OF FARM STANDBY ELECTRICAL SYSTEMS disponible en la American Society of Agricultural Engineers 2950 Niles Road St Joseph MI 49085 CALCOMAN A DE DATOS DEL MODELO ADVERTENCIA PROPOSICI N 65 DE CALIFORNIA El Estado de California sabe que el escape del motor y algunos de sus componentes causan c ncer defectos de nacimiento y otros da os reproductivos ADVERTENCIA PROPOSICI N 65 DE CALIFORNIA Este producto contiene o emite qu micos que el Estado de California sabe que causan c ncer defectos de nacimiento u otros da os reproductivos 23 Informaci n general 1 1 DESEMPAQUE Retire todo el material de empaque Retire la caja separada de accesorios e Retire el generador de la caja 1 1 1 CAJA DE ACCESORIOS Revise todo el contenido Si alguna parte no se encuentra o est dafiada ubique a un concesionario autorizado en el telf 1 888 436 3722 e 1 Manual del propietario 1 Unidad de manu
19. attraper fermement la poign e de rappel et tirer jusqu ce qu une r sistance se fasse sentir Remonter rapidement et d marrer Lorsque le moteur d marre mettre le bouton Choke Etrangleur sur la position 1 2 CHOKE Etrangleur moiti jusqu ce que le moteur fonctionne doucement et ensuite sur la position RUN Marche Si le moteur vibre remettre le levier Choke Etrangleur sur la position 1 2 CHOKE Etrangleur moiti jusqu ce que le moteur fonctionne doucement et ensuite sur la position RUN Marche REMARQUE Si le moteur chauffe mais ne continue pas fonctionner mettre le levier de l trangleur sur FULL Etrangleur plein et r p ter les instructions de d marrage Sch ma 9 Soupape d arr t SOUPAPE D ARR T Sch ma 10 Position de l trangleur LEVIER D TRANGLEUR GAUCHE TRANGLEUR DROITE FONCTIONNEMENT IMPORTANT Ne pas surcharger le g n rateur Aussi ne pas surcharger les prises individuelles du panneau Ces prises sont prot g es contre la surcharge avec des disjoncteurs de type pousser pour r enclencher Si la valeur nominale d amp rage d un disjoncteur est d pass e ce disjoncteur s ouvre et la puissance lectrique de cette prise est perdue Lire attentivement la section Ne pas surcharger le g n rateur 2 9 D MARRAGE DES MOTEURS D MARRAGE LECTRIQUE Ne jamais d marrer ou a
20. cada vez 2 7 2 ANADIR GASOLINA PELIGRO f Nunca llene el tanque de combustible en el ES interior de la casa Evite derramar gasolina sobre un motor caliente Deje enfriar al motor completamente antes de a adir combustible Nunca llene el tanque de gasolina mientras el motor est funcionando o est caliente NO encienda cigarrillos o fume cuando est llenando el tanque de combustible La gasolina es altamente INFLAMABLE y sus vapores son EXPLOSIVOS A No sobrecargue el tanque de combustible sa Deje siempre espacio para la expansi n del combustible Si el tanque est muy lleno el combustible puede caer sobre el motor caliente y causar un incendio o explosi n Limpie cualquier derrame de combustible inmediatamente 28 Use gasolina sin plomo REGULAR para el motor del generador No use gasolina Premium No use aceite con gasolina Limpie el rea alrededor de la tapa de llenado de combustible s quela Lentamente a ada gasolina regular sin plomo al tanque de combustible Llene hasta el fondo del filtro de pantalla Tenga cuidado de no llenarlo demasiado Figura 8 Instale la tapa del combustible y limpie la gasolina que se haya derramado IMPORTANTE Es importante evitar que se formen dep sitos de goma en las partes del sistema de combustible como el carburador la manguera de combustible o el tanque durante el almacenamiento Los combustibles mezclados con alcoholes llamados gasohol etanol o metanol pueden at
21. d allumage chaque saison Changer l huile apr s les 30 premi res heures de fonctionnement puis chaque saison Changer l huile et le filtre huile tous les mois lors du fonctionnement sous une charge lourde ou des temp ratures lev es Nettoyer plus souvent dans des conditions de fonctionnement sales Remplacer les pi ces du filtre air s il est impossible de les nettoyer correctement V rifier le jeu des soupapes et r gler si n cessaire apr s les 50 premi res heures de fonctionnement et toutes les 100 heures par la suite 3 2 CARACT RISTIQUES TECHNIQUES DES PRODUITS 3 2 1 CARACT RISTIQUES TECHNIQUES DU GENERATEUR Puissance 2 7 5 KW Puissance de 5 510 9 375 kW Tension c a nominale 120 240 Charge nominale c a max Couranta 240 V iiit 31 25 A Couranta oe pen LT 62 5 A Fr quence nominale 60 Hz 3 600 RPM Monophas e Le wattage et le courant maximum sont soumis et limit s par ces facteurs tels que le contenu en Btu de carburant la temp rature ambiante l altitude l tat du moteur etc La puissance maximale diminue d environ 3 5 pour chaque tranche de 1 000 pieds au dessus du niveau de la mer et diminuera galement d environ 1 pour chaque tranche de 6 10
22. d effectuer toute maintenance sur le g n rateur d brancher la batterie de d marrage du moteur le cas ch ant afin d emp cher un d marrage accidentel D brancher le c ble de la borne de la batterie signal e par l inscription NEGATIVE N gatif NEG ou le signe en premier Rebrancher ce c ble en dernier En cas d accident caus par lectrocution couper imm diatement la source d alimentation lectrique Si cela est impossible essayer de lib rer la victime du conducteur sous tension EVITER TOUT CONTACT DIRECT AVEC LA VICTIME Utiliser un objet non conducteur comme une corde ou une planche pour lib rer la victime du conducteur sous tension Si la victime est inconsciente assurer les premiers secours et demander une aide m dicale imm diate RISQUES D INCENDIE L essence est extr mement INFLAMMABLE et ses vapeurs sont EXPLOSIVES Ne pas produire de fum e flammes nues tincelles ou chaleur proximit de l endroit l essence est manipul e Ne jamais ajouter de carburant lorsque l unit fonctionne ou est chaude Laisser le moteur compl tement refroidir avant d ajouter du carburant Ne jamais remplir le r servoir d essence l int rieur Respecter toutes les lois r glementant le stockage et la manipulation de l essence Ne pas trop remplir le r servoir d essence Toujours laisser de la place pour l expansion du carburant En cas de suremplissage du r servoir le carburant peut d border sur un moteur ch
23. des re us En tant que propri taire du g n rateur vous devez cependant savoir que Generac pourra refuser tout et ou partie de la couverture de la garantie ou de la responsabilit si votre g n rateur et ou toute pi ce de celui ci ne fonctionne plus du fait d un usage abusif d une n gligence d une mauvaise maintenance ou de modifications non approuv es ou de l utilisation de pi ces contrefaites et ou provenant de l conomie souterraine n ayant pas t fabriqu es fournies ou approuv es par Generac Vous tes charg de contacter un d positaire de garantie agr par Generac d s qu un probl me se pr sente Les r parations effectu es dans le cadre de la garantie devront tre faites dans une p riode raisonnable inf rieure 30 jours Le service de garantie peut tre organis en contactant votre d positaire ou un d positaire de service de garantie agr par Generac Pour conna tre le d positaire de service de garantie agr par Generac situ le plus pr s appeler notre num ro gratuit 1 800 333 1322 REMARQUE IMPORTANTE Cet nonc de garantie explique vos droits et obligations dans le cadre de la garantie du Syst me de Contr le des missions garantie du SCE qui vous est fournie par Generac conform ment au droit de l tat f d ral Consulter galement les Garanties limit es de Generac pour Generac Power Systems Inc jointes au pr sent document sur un feuillet s par qui vous est ga
24. during operation Keep clear of the generator until it has cooled to avoid severe burns Do NOT operate generator in the rain Do not alter the construction of the generator or change controls which might create an unsafe operating condition Never start or stop the unit with electrical loads connected to receptacles AND with connected devices turned ON Start the engine and let it stabilize before connecting electrical loads all electrical loads before shutting down the generator Do not insert objects through unit s cooling slots When working on this equipment remain alert at all times Never work on the equipment when physically or mentally fatigued Safety Rules Never use the generator or any of its parts as a step Stepping on the unit can stress and break parts and may result in dangerous operating conditions from leaking exhaust gases fuel leakage oil leakage etc On electric start models disconnect the POSITIVE battery cable from the engine starter OR the NEGATIVE battery cable from the battery terminal whichever 1 easier before transporting the generator NOTE This generator is equipped with a spark arrestor muffler The spark arrestor must be maintained in effective working order by the owner operator In the State of California a spark arrestor is required by law Section 4442 of the California Public Resources Code Other states may have similar laws Federal laws apply on federa
25. et ou provenant de l conomie souterraine LES PI CES RELATIVES AUX MISSIONS PEUVENT INCLURE CE QUI SUIT LE CAS CH ANT SYST ME DE DOSAGE DU CARBURANT 4 SYST ME D INJECTION D AIR A CARBURATEUR ET PI CES INTERNES A VANNE IMPULSION D AIR B R GULATEUR DE PRESSION 5 SYST ME D CHAPPEMENT SYST ME D INDUCTION D AIR A CATALYSEUR A COLLECTEUR D ADMISSION B R ACTEUR THERMIQUE B FILTRE AIR C COLLECTEUR D CHAPPEMENT SYST ME D ALLUMAGE A BOUGIES D ALLUMAGE B BOBINES MODULE D ALLUMAGE 2 me partie R f rence 0H1911 R v A 01 09 57 GARANTIE LIMIT E DE DEUX ANS GENERAC POWER SYSTEMS POUR LES GENERATEURS PORTABLES SERIE GP La soci t Generac Power Systems Inc Generac garantit que pendant une p riode de deux ann es compter de la date d achat d origine ses g n rateurs s rie GP ne pr senteront aucun d faut mat riel ni de fabrication pour les l ments et la p riode mentionn e ci apr s Generac r parera ou remplacera comme il le jugera n cessaire toute pi ce jug e d fectueuse apr s un examen une inspection et un test r alis s par Generac ou un d positaire de service de garantie agr par Generac Tout quipement d clar d fectueux par l acqu reur le propri taire doit tre retourn et examin par le d positaire de service de garantie agr par Generac le plus proche Tous les frais d envoi payer dans le cadre de la garantie dont le retour l usin
26. et contacter le d positaire agr le plus proche pour les pi ces qui n cessitent une r paration ou un remplacement e Faire fonctionner le g n rateur uniquement sur des surfaces de niveau et o il ne sera pas expos l humidit aux salet s la poussi re ou aux vapeurs corrosives excessives e Tenir les mains les pieds les v tements etc distance des courroies de transmission des ventilateurs et d autres pi ces mobiles Ne jamais retirer tout prot ge ventilateur pendant que l unit fonctionne e Certaines pi ces du g n rateur deviennent extr mement chaudes pendant le fonctionnement Rester distance du g n rateur tant qu il n a pas refroidi afin d viter des br lures graves e NE PAS faire fonctionner le g n rateur sous la pluie e Ne pas modifier la construction du g n rateur ni les commandes ce qui pourrait cr er une condition de fonctionnement dangereuse e Ne jamais d marrer ou arr ter l unit avec les charges lectriques branch es aux prises ET avec des dispositifs branch s sous tension D marrer le moteur et le laisser se stabiliser avant de brancher les charges lectriques D brancher toutes les charges lectriques avant d arr ter le g n rateur e Ne pas ins rer d objet dans les fentes de refroidissement de l unit e Lors du travail sur cet quipement conserver l alerte tout moment Ne jamais travailler sur l quipement en cas de fatigue physique ou mentale e Ne jamai
27. granizo erupci n volc nica agua o inundaciones tornados o huracanes El da o relacionado a roedores y o plaga de insectos Los productos que son modificados o alterados de manera no autorizada por Generac por escrito Cualquier da o incidental consecuencial o indirecto causado por defectos en los materiales y mano de obra o cualquier retraso en reparar o reemplazar las partes defectuosas Falla debido a una mala aplicaci n Gastos de tel fono tel fono celular fax acceso a internet u otros gastos de comunicaci n Gastos relacionados a instrucciones del cliente o detecci n de problemas donde no se encuentre defecto de f brica Equipo de alquiler usado mientras se realiza las reparaciones de garant a Flete de un d a para otro o costos especiales de embarque para los repuestos Sobretiempos vacaciones o trabajo de emergencia Bater as de arranque fusibles bombillos de luz y fluidos de motor ESTA GARANT A REEMPLAZA A TODAS LAS OTRAS GARANT AS EXPRESAS 0 IMPL CITAS ESPEC FICAMENTE GENERAC NO OFRECE OTRAS GARANT AS COMO DE MERCANTIBILIDAD O ADECUACI N A UN USO PARTICULAR Cualquier garant a impl cita permitida por ley estar limitada en duraci n a los t rminos de la garant a expresa dispuesta aqu Algunos estados no permiten limitaciones en cu nto dura una garant a impl cita de modo que la limitaci n expresada arriba puede no aplicarse a usted LA NICA RESPONSABILIDAD DE GENERAC SER
28. its option repair or replace any part which upon examination inspection and testing by Generac or a Generac Authorized Warranty Service Dealer is found to be defective Any equipment that the purchaser owner claims to be defective must be returned to and examined by the nearest Generac Authorized Warranty Service Dealer All transportation costs under the warranty including return to the factory are to be borne and prepaid by the purchaser owner This warranty applies only to Generac GP Series portable generators and is not transferable from original purchaser Save your proof of purchase receipt If you do not provide proof of the initial purchase date the manufacturer s shipping date of the product will be used to determine the warranty period WARRANTY SCHEDULE Consumer applications are warranted for two 2 years Commercial and Rental applications are warranted for one 1 year or 1000 hours maximum whichever comes first CONSUMER APPLICATION YEAR ONE 100 one hundred percent coverage on Labor and Part s proof of purchase and maintenance is required All Components YEAR TWO 100 one hundred percent coverage on Part s proof of purchase and maintenance is required All Components COMMERCIAL RENTAL APPLICATION YEAR ONE 100 one hundred percent or 1 000 hours whichever occurs first coverage on Labor and Part s proof of purchase and maintenance is required All Components INTERNATIONAL YEAR ONE or 1000 h
29. la bater a 32 3 4 DAR SERVICIO AL LIMPIADOR DE AIRE El motor no funcionar apropiadamente y puede da arse si se usa un limpiador de aire sucio Limpie o reemplace el filtro de papel del limpiador cada a o Limpielo o reempl celo con mayor frecuencia si se opera en condiciones de suciedad figura 14 Limpieza o reemplazo del filtro de aire de papel Retire la cubierta del limpiador de aire y quite el filtro de papel Limpie el filtro de papel golpe ndolo ligeramente sobre una superficie s lida Si el filtro est demasiado sucio reempl celo con uno nuevo Disponga del filtro viejo en forma apropiada Limpie la cubierta del limpiador de aire luego inserte un nuevo filtro de papel en la base del limpiador de aire Reinstale la cubierta del limpiador de aire Figura 14 Filtro de aire PASADOR NOTA Para ordenar un filtro de aire nuevo por favor p ngase en contacto con el centro de servicio autorizado m s cercano al 1 800 333 1322 3 5 ALMACENAMIENTO POR LARGO PLAZO Es importante evitar que se formen dep sitos de goma en las partes esenciales del sistema de combustible como el carburador la manguera de combustible o el tanque durante el almacenamiento Asimismo la experiencia indica que los combustibles mezclados con alcoholes llamados gasohol etanol o metanol pueden atraer la humedad lo que llega a la separaci n y formaci n de cidos durante el almacenamiento Los gase
30. las mismas Calentador de chispa de aceite 85 000 1 225 bombillas La potencia nominal de las herramientas aparatos y Calentador de chispa de aceite 30 000 150 motores normalmente se puede encontrar en la etiqueta de datos o Pulverizador de pintura sin aire 1 3 600 calcoman a fijada en el dispositivo Pulverizador de pintura sin aire de mano e Siel aparato herramienta o motor no muestran la potencia multiplique voltios por amperios nominales para determinar los vatios volts x Refrigeradora amps vatios Cocina lent Algunos motores el ctricos como los del tipo inducci n requieren Bomba sumergible 1 1 2 2800 alrededor de ires veces potencia para arrancar que para Bomba sumergible 1 HP 2000 funcionar Este transitorio de potencia dura s lo unos pocos segundos Bomba sumergible 1 2 HP 1500 al arrancar tales motores Aseg rese de tener en cuenta esta alta ane de 800 a 1050 potencia de arranque al seleccionar dispositivos el ctricos que se conectar n al generador Sierra de banco 10 de 1750 a 2000 1 Sepa la potencia necesaria para arrancar el motor m s grande 1 P 2 Sume a esa cifra la potencia de funcionamient
31. le moteur manuellement Soupape d arr t Soupape entre le r servoir d essence et le carburateur Entr e du chargeur de batterie Cette prise a la capacit de recharger la batterie rechargeable c c de 12 volts quip e d un chargeur d adaptateur de 12 volts qui est inclus dans la boite d accessoires Derri re l entr e du chargeur de la batterie il y a un fusible en ligne de 1 50 A qui se trouve l int rieur du panneau de commande afin de prot ger la batterie d marrage lectrique uniquement Batterie Met sous tension le d marreur lectrique mod les de d marrage lectrique uniquement Horom tre Rel ve les heures de fonctionnement Fonctionnement Sch ma 3 Commandes du g n rateur 45 Fonctionnement 2 2 HOROM TRE L horom tre rel ve les heures de fonctionnement pour la maintenance programm e Un message CHG OIL s affichera toutes les 100 heures Le message clignotera une heure avant et une heure apr s chaque intervalle de 100 heures laissant une marge de deux heures pour effectuer l entretien Ce message commencera clignoter la 99 me heure et se d sactivera la 10 me heure laissant une marge de deux heures pour effectuer l entretien Toutes les 200 heures l ic ne SVC situ e en bas gauche de l cran clignotera Le message clignotera une heure avant et une heure apr s chaque intervalle de 200 heures laissant une marge de deux heu
32. minor or moderate injury NOTE Notes contain additional information important to a procedure and will be found within the regular text body of this manual These safety warnings cannot eliminate the hazards that they indicate Common sense and strict compliance with the special instructions while performing the action or service are essential to preventing accidents Four commonly used safety symbols accompany the DANGER WARNING and CAUTION blocks The type of information each indicates is as follows This symbol points out important safety information that if not followed could endanger personal safety and or property of others This symbol points potential explosion S hazard amp This symbol points potential fire hazard This symbol points out potential electrical shock hazard GENERAL HAZARDS Never operate in an enclosed area or indoors For safety reasons the manufacturer recommends that the maintenance of this equipment is carried out by an Authorized Dealer Inspect the generator regularly and contact the nearest Authorized Dealer for parts needing repair or replacement Operate generator only on level surfaces and where it will not be exposed to excessive moisture dirt dust or corrosive vapors Keep hands feet clothing etc away from drive belts fans and other moving parts Never remove any fan guard or shield while the unit is operating Certain parts of the generator get extremely hot
33. moteur 120 V et ou 240 V 30 A monophas 60 Hz 3 Disjoncteurs c a Chaque prise est fournie avec un disjoncteur de type pousser pour r enclencher pour prot ger le g n rateur contre les surcharges lectriques 4 Vidange d huile Utilis pour vidanger l huile de moteur 5 Filtre air Filtre l air aspir par le moteur 9A 10 Etrangleur Utilis au d marrage d un moteur froid R servoir d essence Voir les Caract ristiques techniques du g n rateur pour la contenance du r servoir Borne de mise a la terre Relie le g n rateur a une terre approuv e Voir la section Mise la terre du g n rateur pour plus d informations Interrupteur Run Stop Marche Arr t Contr le le fonctionnement du g n rateur mod les d marrage manuel Interrupteur de d marrage Utilis pour d marrer le moteur partir du d marreur du moteur mod les d marrage lectrique uniquement Pot d chappement Rend silencieux le moteur Sch ma 2 Panneau de commande Poign e Pivoter et r tracter pour le stockage Appuyer sur le bouton ressort pour d placer les poign es Chapeau de gaz assis Emplacement de remplissage d huile Jauge de carburant Indique le niveau de carburant dans le r servoir Remplissage d huile Ajouter de l huile ici Lanceur rappel Utiliser pour d marrer
34. panel receptacles These outlets are protected against overload with push to reset type circuit breakers If amperage rating of any circuit breaker is exceeded that breaker opens and electrical output to that receptacle is lost Read Don t Overload the Generator carefully 2 10 STOPPING THE ENGINE Shut off all loads then unplug the electrical loads from generator panel receptacles Never start or stop the engine with electrical devices plugged in and turned on Let engine run at no load for several minutes to stabilize the internal temperatures of engine and generator Move Run Stop switch to OFF position Close fuel valve 2 11 LOW OIL LEVEL SHUTDOWN SYSTEM The engine is equipped with a low oil level sensor that shuts down the engine automatically when the oil level drops below a specified level If the engine shuts down by itself and the fuel tank has enough gasoline check engine oil level 2 11 1 SENSING LOW OIL LEVEL If the system senses a low oil level during operation the engine shuts down The engine will not run until the has been refilled to the proper level Maintenance 2 12 CHARGING THE BATTERY ELECTRIC START UNITS ONLY A DANGER f Storage batteries give off explosive hydrogen gas while recharging An explosive mixture will remain around the battery for a long time after it has been charged The slightest spark can ignite the hydrogen and cause an explosion Such an explosion can s
35. par Generac conform ment au paragraphe 4 qui suit Ces pi ces r par es ou remplac es dans le cadre de la Garantie du SCE seront garanties pour le reste de la dur e de la Garantie du SCE Toute pi ce garantie dont il est pr vu une inspection r guli re dans le Manuel d entretien sera garantie pendant toute la dur e de la Garantie du SCE Toute d claration contenue dans le Manuel d entretien et relative l effet de r paration ou remplacement si n cessaire ne r duira pas la dur e de la Garantie du SCE Ces pi ces r par es ou remplac es dans le cadre de la Garantie du SCE seront garanties pour le reste de la dur e de la Garantie du SCE Toute pi ce garantie dont le remplacement est pas pr vu au cours des maintenances obligatoires mentionn es dans le Manuel d entretien sera garantie pour la p riode pr c dant la date du premier remplacement pr vu Si la pi ce devient d fectueuse avant le premier remplacement pr vu elle sera r par e ou remplac e par Generac conform ment au paragraphe 4 qui suit Ces pi ces relatives aux missions r par es ou remplac es dans le cadre de la Garantie du SCE seront garanties pour le reste de la dur e pr c dant la date de leur premier remplacement pr vu La r paration ou le remplacement de toute pi ce relative aux missions et garantie dans le cadre de la Garantie du SCE sera r alis sans frais pour le propri taire dans un service de garantie agr par Generac Nonobstan
36. procedimiento m todo de trabajo o t cnica de operaci n que el fabricante no recomienda espec ficamente aseg rese de que sea seguro para los dem s Asimismo aseg rese que el procedimiento m todo de trabajo o t cnica de operaci n utilizada no vuelva inseguro al generador LA INFORMACI N CONTENIDA AQU SE 50 EN M QUINAS EN PRODUCCI N AL MOMENTO DE LA PUBLICACI N GENERAC SE RESERVA EL DERECHO DE MODIFICAR ESTE MANUAL EN CUALQUIER MOMENTO REGLAS DE SEGURIDAD A lo largo de esta publicaci n y en lo que respecta a las etiquetas y calcoman as fijadas en el generador los bloques de PELIGRO ADVERTENCIA CUIDADO Y NOTA se usan para alertar al personal sobre instrucciones especiales sobre una operaci n en particular que puede ser peligrosa 1 se ejecuta en forma incorrecta o sin cuidado Obs rvelas con cuidado Sus definiciones son como sigue PELIGRO INDICA UNA SITUACI N PELIGROSA O ACCI N QUE SI NO SE EVITA COMO RESULTADO LA MUERTE 0 UN DANO SERIO AADVERTENCIA Indica una situaci n peligrosa o acci n que si no se evita podr a traer como resultado la muerte o un da o serio ACUIDADO Indica una situaci n peligrosa o acci n que si no se evita puede traer como resultado un da o menor 0 moderado NOTA Las notas contienen informaci n adicional importante para un procedimiento y se les encontrar dentro del cuerpo de este manual Estas advertencias de segu
37. que Generac le proporciona Generac siguiendo las leyes federales Tambi n vea Garant as limitadas de Generac para los sistemas de potencia de Generac Inc que se adjunta a este manual en una hoja separada tambi n proporcionada a usted por Generac Tenga en cuenta que esta garant a no se aplicar a ning n da o incidental consecuencial o indirecto causado por defectos en los materiales y mano de obra o cualquier retraso en reparar o reemplazar las partes defectuosas Esta garant a reemplaza a todas las otras garant as expresas o impl citas Espec ficamente Generac no ofrece otras garant as como la de mercantibilidad O adecuaci n a un uso particular Algunos estados no permiten limitaciones en cu nto dura una garant a impl cita de modo que la limitaci n expresada arriba puede no aplicarse a usted La garant a ECS se aplica s lo al sistema de control de emisiones de su nuevo equipo Si hay alg n conflicto en t rminos entre la garant a ECS y la garant a de Generac se aplicar la de Generac Ambas garant as describen derechos y obligaciones importantes respecto a su nuevo motor El servicio de garant a puede ser realizado s lo por un servicio de garant a autorizado de Generac Cuando se requiera servicio de garant a se debe presentar evidencia que muestre la fecha de venta al comprador propietario original Si usted tuviera alguna pregunta respecto a sus derechos y responsabilidades de garant a deber ponerse en con
38. s 3 3 3 MAINTENANCE DU MOTEUR Toujours d brancher le c ble n gatif de la batterie en cas de travail sur le g n rateur Toujours d brancher les fils de bougie des bougies d allumage et les tenir loign s de celles ci 3 3 4 V RIFICATION DU NIVEAU D HUILE Se reporter la section Avant le d marrage du g n rateur pour plus d informations sur la v rification du niveau d huile Le niveau d huile doit tre v rifi avant chaque utilisation ou au minimum toutes les huit heures de fonctionnement Il est n cessaire de conserver un certain niveau d huile 9 3 5 CHANGEMENT DE L HUILE Changer l huile apr s les 30 premi res heures de fonctionnement Changer l huile toutes les 100 heures ou chaque saison par la suite Changer l huile plus souvent en cas d utilisation de cette unit dans un environnement sale ou poussi reux ou dans des temp ratures tr s lev es ATTENTION De l huile chaude peut entra ner des br lures Laisser le moteur refroidir avant de vidanger l huile Eviter un contact prolong ou r p t de la peau avec de l huile usag e Laver minutieusement les zones expos es avec du savon Respecter les instructions suivantes pour changer l huile apr s que le moteur ait refroidi e Nettoyer la zone autour du tuyau de vidange d huile e Retirer le bouchon de vidange d huile du moteur et le bouchon pour le remplissage d huile afin de vidanger toute l huile dans un r cipient adapt e L
39. te tout seul et que le r servoir d essence a assez d essence v rifier le niveau d huile du moteur 2 11 1 D TECTION DE BAS NIVEAU D HUILE Si le syst me d tecte un niveau d huile bas pendant le fonctionnement le moteur s arr te Le moteur ne fonctionnera pas tant que de l huile n aura pas t rajout e pour atteindre le bon niveau 49 Maintenance 2 12 CHARGEMENT DE LA BATTERIE UNITES A DEMARRAGE ELECTRIQUE UNIQUEMENT ADANGER f Les batteries rechargeables mettent un gaz 3 hydrog ne explosif lors du rechargement Un m lange explosif restera autour de la batterie longtemps apr s son chargement La plus petite tincelle peut enflammer l hydrog ne et causer une explosion Cette explosion peut faire voler en clats la batterie et causer la c cit ou d autres blessures graves ADANGER Ne pas produire de fum e flammes nues tincelles ou autre source de chaleur proximit de la batterie Porter des lunettes de protection un tablier en caoutchouc et des gants en caoutchouc lors du travail autour de la batterie Le fluide d lectrolyte de la batterie est une solution d acide sulfurique extr mement corrosive qui peut causer des br lures graves En cas d claboussure rincer imm diatement la zone l eau claire REMARQUE La batterie envoy e avec le g n rateur a t compl tement charg e Une batterie peut perdre une partie de sa charge lorsqu elle n est pas utilis e pendant des p riode
40. un cordon 4 fils avec mise la terre adapt la prise et la charge souhait e Le cordon doit tre con u pour 250 V 30 A ou plus Sch ma 6 46 Sch ma 6 Prise 120 240 V c a 30 A 120 V 240 V 30A Utiliser cette prise pour faire fonctionner les charges monophas es de 120 V 60 Hz n cessitant 3 600 watts 3 6 kW d alimentation 30 A ou des charges monophas es de 240 V c a 60 Hz n cessitant 7 200 watts 7 2 kW d alimentation 30 A La prise est prot g e par deux disjoncteurs de type pousser pour r enclencher de 30 A 2 4 UTILISATION DU G N RATEUR Si des probl mes se pr sentent lors du fonctionnement du g n rateur merci d appeler la ligne d assistance pour les g n rateurs au 1 888 436 3722 DANGER Utiliser g n rateur l int rieur PEUT VOUS TUER EN QUELQUES MINUTES Les gaz d chappement du g n rateur contiennent du monoxyde de carbone C est un gaz toxique invisible et inodore NE JAMAIS utiliser l int rieur Utiliser UNIQUEMENT d une maison ou d un garage l EXTERIEUR et loin des 1 les portes et les fen tres portes et fen tres sont ouvertes ventilations 24 1 MISE LA TERRE DU GENERATEUR Le National Electrical Code Code lectrique national exige que le b ti et que les pi ces externes lectriquement conductrices de ce g n rateur soient correctement reli es une terre approuv e Sch ma 7 Les codes lectriq
41. 0 inch or 0 76 mm Gasoline Capacity 8 U S gallons ODUM TY irc os See Chart in Adding Engine Oil Section Oil Capacity 1 0 Liters 1 06 Qts Run Time 50 Load 12 Hours Class 11 Emission Certified Maintenance 3 2 3 EMISSIONS INFORMATION The Environmental Protection Agency EPA requires that this generator comply with exhaust emission standards The engine used in this generator is certified to meet the applicable EPA emission levels lt is important to follow the maintenance specifications provided in this manuals to ensure that the engine complies with the applicable emission standards for the duration of the engine s life The emission control system on this generator consists of the following Air Induction system e ignition System Pipe Manifold Spark Plug Air Cleaner Ignition Coil e Exhaust System e Fuel System Exhaust manifold Carburetor Muffler The Emissions Compliance Period referred to on the Emissions Compliance Label indicates the number of operating hours for which the engine has been shown to meet EPA emission requirements 3 3 GENERAL RECOMMENDATIONS The warranty of the generator does not cover items that have been subjected to operator abuse or negligence To receive full value from the warranty the operator must maintain the generator as instructed in this manual Some adjustments will need to be made periodically to prop
42. 1 re partie R f rence 0H1911 R v 01 09 56 GARANTIE DU SYST ME DE CONTR LE DES MISSIONS Garantie du Syst me de Contr le des missions garantie du SCE pour l quipement utilisant de petits moteurs allumage command a Applicabilit La pr sente garantie s applique l quipement qui utilise de petits moteurs hors route La p riode de la garantie du 5 commencera la date d achat de livraison du nouvel quipement son acqu reur propri taire d origine final et durera pendant les 24 mois suivant ladite date b Couverture de la garantie g n rale des missions Generac garantit l acqu reur au propri taire d origine final du nouveau moteur ou quipement et chacun des acqu reurs propri taires suivant que lorsqu il est install le SCE 1 Est con u construit et quip dans le respect de toutes les r glementations applicables et 2 Ne comporte aucune pi ce d fectueuse ni ne pr sente aucun d faut de fabrication tout moment de la p riode de garantie du SCE c La garantie sur les pi ces relatives aux missions sera interpr t e de la facon suivante 1 Toute pi ce garantie dont le remplacement n est pas pr vu au cours des maintenances obligatoires mentionn es dans le Manuel d entretien sera garantie pour toute la dur e de la Garantie du SCE Si l une de ces pi ces devient d fectueuse pendant la dur e de la Garantie du SCE elle sera r par e ou remplac e
43. 341 120 20 Amp Recept culo d plex 26 Detecci n de fallas AE 34 23 2 Receptaculo de 120 240 VAC 30 26 4 1 de detecci n de problemas 34 2 4 C mo usar el 26 24 Conan atera del Danera erectos 26 DUES condado lindaa 35 2 4 2 Conexi n de las cargas el ctricas 27 57 PAL ANT TR tuant 36 2 6 Gu a de referencia de 27 2 7 Antes de arrancar el 28 2 7 1 Agregar aceite de 28 2 7 2 Agregar gasolina 28 2 8 Arranque de motores de arranque 1 28 2 9 Arranque de motores de arranque el ctrico 29 2 10 Deteniendo el 29 2 11 Sistema de apagado por bajo nivel de aceite 29 2 11 1 Sensando el nivel de aceite 29 2 12 de la bater a unidades de arranque el ctrico solamente vecina to s 30 20 Introducci n INTRODUCCI N Gracias por comprar este modelo de Generac Power Systems Inc Este modelo es un generador impulsado por motor refrigerado por aire compacto y de alto rendimiento dise ado para proporcio
44. 53190 Part No 0H1911 Rev 01 09 16 EMISSION CONTROL SYSTEM WARRANTY Emission Control System Warranty ECS warranty for equipment using small spark ignited engines a Applicability This warranty shall apply to equipment that uses small off road engines The ECS Warranty period shall begin on the date the new equipment is purchased by delivered to its original end use purchaser owner and shall continue for 24 consecutive months thereafter b General Emissions Warranty Coverage Generac warrants to the original end use purchaser owner of the new engine or equipment and to each subsequent purchaser owner that the ECS when installed was 1 Designed built and equipped so as to conform with all applicable regulations and 2 Free from defects in materials and workmanship which cause the failure of a warranted part at any time during the ECS Warranty Period c The warranty on emissions related parts will be interpreted as follows 1 Any warranted part that is not scheduled for replacement as required maintenance in the Owner s Manual shall be warranted for the ECS Warranty Period If any such part fails during the ECS Warranty Period it shall be repaired or replaced by Generac according to Subsection 4 below Any such part repaired or replaced under the ECS Warranty shall be warranted for the remainder of the ECS Warranty Period Any warranted part that is scheduled only for regular inspection as specified in the Owner s Man
45. CESSORY BOX Check all contents If any parts are missing or damaged locate an authorized dealer at 1 888 436 3722 1 Owner s Manual 1 Handle Assembly e 1 Liter Oil SAE 30 1 Frame Foot 2 Never Flat Wheels e 1 Battery Charger electric start only e 1 Hardware Bag containing the following e 2 Rubber Feet e 2 8 Bolt Long 2 1 2 Axle Pins 2 8 Bolts Short 2 Cotter Pins e 2 8 Acorn Nut 2 1 2 Flat Washers 4 Hex Flanged M8 Nuts 2 Short Bolts e 2 Lock Washers 2 Flange Nuts electric start only 1 2 ASSEMBLY The generator requires some assembly prior to using it If problems arise when assembling the generator please call the Generator Helpline at 1 888 77LOWES 1 2 1 ASSEMBLING THE ACCESSORY KIT The wheels are designed into the unit to greatly improve the portability of the generator You will need the following tools to properly install the accessory kit Needle Nose Pliers Ratchet and a 13mm 1 2 socket e 13mm 1 2 box wrench NOTE The wheels are not intended for over the road use 1 Referto Figure 1 and install the Wheels as follows Slide the Axle Pins through the Wheel 1 2 Flat Washer and Wheel Bracket on the frame Insert the Cotter Pin through the Axle Pin then bend the tabs of the Cotter Pins outward to lock into place 2 Refer to Figure 1 and install the Frame Foot and Rubber Bumpers as shown Slide the Rubber Bumper studs through
46. Check Oil Level Change Oil Check Valve Clearance Service Air Filter Replace Spark Plug At Each Use Every 100 hours or Every Season Fvery Season Every 200 hours or Every Season Every Season Change oil after first 30 hours of operation then every season Change oil and oil filter every month when operating under heavy load or in high temperatures Clean more often under dirty or dusty operating conditions Replace air filter parts if they cannot be adequately cleaned Check valve clearance and adjust if necessary after first 50 hours of operation and every 100 hours thereafter 3 2 PRODUCT SPECIFICATIONS 3 2 1 GENERATOR SPECIFICATIONS Rated POWBE stat tte i eerta mentes 7 5 kW 6 POWER e 9 375 kW Rated AC Voltage 120 240 Rated Max AC Load Current 240V seen 31 25 Amps Current 120V cierres 62 5 Amps Rated Frequency 60 Hz 3600 RPM a a Single Phase Maximum wattage and current are subject to and limited by such factors as fuel Btu content ambient temperature altitude engine condition etc Maximum power decreases about 3 596 for each 1 000 feet above sea level and will also decrease about 1 for each 6 C 10 F above 16 C 60 F ambient temperature 3 2 2 ENGINE SPECIFICATIONS DISDIaCemefil tera 420 Spark Plug Champion N9YC or NHSP LDF7TC Spark Plug Gap 0 03
47. E TIENE 1 SISTEMA DE MEDICI N DE COMBUSTIBLE 4 SISTEMA DE INYECCI N DE AIRE A CARBURADOR Y PARTES INTERNAS A V LVULA DE AIRE DE PULSO B REGULADOR DE PRESI N 5 SISTEMA DE ESCAPE 2 SISTEMA DE INDUCCI N DE AIRE A CATALIZADOR A DISTRIBUIDOR DE ENTRADA B REACTOR T RMICO B FILTRO DE AIRE C DISTRIBUIDOR DE ESCAPE 3 SISTEMA DE IGNICI N A BUJ AS B BOBINAS M DULO DE IGNICI N Parte 2 Parte No 0H1911 Rev A 01 09 37 LIMITADA DE DOS 5 DE SISTEMAS DE POTENCIA GENERAC PARA GENERADORES PORTATILES SERIE GP Por un periodo de dos a os desde la fecha de la venta original Generac Power Systems Inc Generac garantiza sus generadores serie GP como libres de defectos en materiales y mano de obra por los items y periodos indicados abajo Generac a su opci n o reemplazar cualquier parte que luego de un examen inspecci n y pruebas realizadas por un concesionario de servicio de garant a autorizado de Generac se encuentre que est defectuoso Cualquier equipo que el comprador propietario reclame como defectuoso debe ser regresado a y examinado por el concesionario de servicio de garant a autorizado por Generac m s cercano Todos los costos de transporte bajo la garant a incluyendo el retorno a la f brica ser n por cuenta y prepagados por el propietario comprador Esta garant a se aplica s lo a los generadores port tiles serie GP de Generac y no es transferible del propi
48. EL MOTOR Apague todas las cargas luego desconecte las cargas el ctricas de los recept culos del panel del generador Nunca arranque ni detenga el motor con dispositivos el ctricos conectados y encendidos Deje que el motor funcione sin carga por algunos minutos para estabilizar las temperaturas internas del motor y del generador Mueva el interruptor de Run Stop a la posici n OFF Cierre la v lvula de combustible 2 11 SISTEMA DE APAGADO POR BAJO NIVEL DE ACEITE motor est equipado con un sensor de bajo nivel de aceite que apaga el motor en forma autom tica cuando el nivel de aceite cae por debajo de un nivel especificado Si el motor se apaga y el tanque de combustible tiene suficiente gasolina revise el nivel de aceite de motor 2 11 1 SENSANDO EL BAJO NIVEL DE ACEITE Si el sistema detecta un bajo nivel de aceite durante la operaci n el motor se apaga El motor no funcionar hasta que se haya llenado aceite de nuevo a su nivel apropiado 29 2 12 CARGA DE LA BATER A ARRANQUE EL ECTRICO SOLAMENTE Las bater as almacenadas sueltan un explosivo Ligas de hidr geno al recargarse Una mezcla explosiva permanecer alrededor de la bater a por largo tiempo luego de que se haya cargado La m s ligera chispa puede encender el hidr geno y causar una explosi n Una explosi n as puede destruir la bater a y causar ceguera y otros da os serios PELIGRO No permita que fumen hagan fuego abierto c
49. ER Utiliser g n rateur l int rieur PEUT VOUS TUER EN QUELQUES MINUTES Les gaz d chappement du g n rateur contiennent du monoxyde de carbone C est un gaz toxique invisible et inodore NE JAMAIS utiliser l int rieur Utiliser UNIQUEMENT d une maison ou d un garage l EXTERIEUR et loin des 1 les portes et les fen tres portes et fen tres sont ouvertes ventilations Les fum es d chappement du moteur contiennent du monoxyde de carbone un gaz toxique invisible et inodore Ce gaz toxique s il est respir en concentrations suffisantes peut entra ner une perte de conscience ou m me la mort Un d bit appropri non obstru d air de refroidissement et de ventilation est important pour corriger le fonctionnement du g n rateur Ne pas modifier l installation ou ne pas laisser m me un blocage partiel de l alimentation de ventilation tant donn que cela peut s rieusement affecter le fonctionnement s r du g n rateur FAUT faire fonctionner le g n rateur l ext rieur syst me d chappement doit tre correctement entretenu Ne rien faire qui pourrait rendre le syst me d chappement dangereux ou non conforme aux codes locaux et ou normes locales Toujours utiliser un d tecteur d oxyde de carbone alimentation par batterie l int rieur conform ment aux instructions du fabricant Sivous commencez vous sentir malade avoir des tourdissements ou vous
50. F au dessus de 16 60 F de temp rature ambiante 3 2 2 CARACT RISTIQUES TECHNIQUES DU MOTEUR D placement cosita oras 420 Type de bougie d allumage Champion N9YC ou NHSP LDF7TC Ecartement de bougie d allumage 0 030 pouces ou 0 76 mm Capacit d essence 8 gallons U S Type d huile Voir tableau dans la section Ajout de l huile de moteur Capacit 1L 1 06 065 Temps d ex cution charge de 50 12 heures Certifi mission de cat gorie Il Maintenance 3 2 3 INFORMATIONS RELATIVES AUX EMISSIONS L Agence pour la protection de l environnement EPA exige que ce g n rateur soit conforme aux normes en mati re d mission d chappement Ce g n rateur est certifi comme respectant tous les niveaux d mission d chappement EPA applicables Il est important de respecter les sp cifications de maintenance indiqu es dans ce manuel afin de s assurer que votre moteur est conforme aux normes applicables en mati re d mission pendant la dur e de vie du moteur Le syst me de contr le des missions de ce g n rateur est compos des l ments suivants Syst me d induction d air e Syst me d allumage Pipe collecteur d admission Bougie d allumage Filtre air Bobine d allumage e Syst me d chappement e Syst me de carburant Collecteur d cha
51. GENERAC 005943 0 7 500 Watt GP Series Portable Generator Owner s Manual MODELS 005942 0 2 VIENA LIMITED WARRANTY m cp D i i gt gt Table of Contents AAA 1 Read this Manual Thoroughly 1 Safety Rules anios 1 Standards Index crees 3 General Information 4 Velo UNPACKING adria 4 1 1 1 Accessory 4 1 2 Assembly ec aes 4 1 2 1 Assembling the Accessory Kit 4 1 2 2 Battery Cable Connection Electric Start Only 4 4 2 1 Know the Generator 4 22 6 2 3 Cord Sets and Connection 95 6 2 3 1 120 VAC 20 Amp Duplex Receptacle 6 2 3 2 120 240 VAC 30 Amp Receptacle 6 2 4 How to Use the 6 24 1 Grounding the 6 2 4 2 Connecting Electrical LOadS 7 2 5 Don t Overload the 7 2 6 Wattage Reference 7 2 7 Before
52. IRE FONCTIONNER LE GENERATEUR NE CHARGE PAS LA BATTERIE ATTENTION A La borne NEGATIVE de la batterie doit 1 Toujours tre DEBRANCHEE EN PREMIER 2 Toujours tre BRANCH E EN DERNIER Sch ma 13 Branchements de la batterie 52 3 4 ENTRETIEN DU FILTRE AIR Le moteur ne fonctionnera pas correctement et pourra tre endommag en cas d utilisation d un filtre air sale Nettoyer ou remplacer le papier du filtre air une fois par an sera n cessaire de le nettoyer ou de le remplacer plus souvent en cas de fonctionnement dans des conditions de salet Sch ma 14 Pour nettoyer ou remplacer le papier du filtre air e Retirer le couvercle du filtre air et retirer le filtre en papier e Nettoyer le filtre en papier en le tapant l g rement sur une surface solide Si le filtre est trop sale il est n cessaire de le remplacer Jeter l ancien filtre de mani re adapt e Nettoyer le couvercle du filtre air puis ins rer le nouveau filtre en papier dans la base du filtre air Remettre le couvercle du filtre air en place Sch ma 14 Filtre air CLI REMARQUE Pour commander un nouveau filtre air merci de contacter le centre d entretien agr le plus proche au 1 800 333 1322 3 5 STOCKAGE LONG TERME Pendant le stockage il est important d emp cher la formation de d p ts de gomme dans les pi ces essentielles du circuit de carburant telles
53. OTENCIAS La apropiada conexi n a tierra del generador ayudar a evitar una descarga el ctrica en el caso en que se presente una falla de tierra en el generador o en los dispositivos conectados Una apropiada conexi n a tierra tambi n ayuda a disipar la electricidad est tica que generalmente se acumula en dispositivos no enterrados 2 4 2 CONEXI N DE LAS CARGAS EL CTRICAS NO conecte cargas de 240 Volt a recept culos de 120 Volt NO conecte cargas trif sicas al generador NO conecte cargas de 50 Hz al generador Deje que el motor se estabilice y caliente por unos minutos antes de arrancar DiSpoSillVO teret Vatios en funcionamiento Aire acondicionado 12 000 1700 Aire acondicionado 24 000 3800 Aire acondicionado 40 000 6000 Cargador de bater as 20 500 Lijadora de bandas 3 Sierra el ctrica Sierra Circular 6 1 2 Secadora de ropa El ctrica 5750 Compresor 1 HP Compresor 3 4 HP Compresor 1 2 HP Rizador de pelo Deshumedecedor Lijadora de disco 9 COMO Ua see ire e Frazada 6160164 iiit
54. Starting the 8 2 7 1 Adding Engine 8 2 7 2 Adding 8 2 8 Starting Pull Start 8 2 9 Starting Electric Start 9 2 10 Stopping the Engine 2 9 2 11 Low Oil Level Shutdown System 9 2 11 1 Sensing Low Oil Level 9 2 12 Charging the Battery Electric Start Units Only 10 Maintenance 10 3 1 Maintenance 10 3 2 Product Specifications 10 3 2 1 Generator 10 3 2 2 Engine 5 10 3 2 3 Emissions 11 3 3 General 11 3 3 1 Generator 11 3 3 2 Clean the 11 3 8 3 Engine 11 3 3 4 Checking Oil 11 3 8 5 Changing the Oil 11 3 3 6 Re
55. aces clean A soft bristle brush may be used to loosen caked on dirt oil etc vacuum cleaner may be used to pick up loose dirt and debris Low pressure air not to exceed 25 psi may be used to blow away dirt Inspect cooling air slots and openings on the generator These openings must be kept clean and unobstructed 3 9 3 ENGINE MAINTENANCE A DANGER When working on the generator always disconnect negative cable from battery Also disconnect spark plug wire from spark plug and keep wire away from spark plug 3 9 4 CHECKING OIL LEVEL See the Before Starting the Generator section for information on checking the oil level The oil level should be checked before each use or at least every eight hours of operation Keep the oil level maintained 9 3 5 CHANGING THE 011 Change the oil after the first 30 hours of operation Change the oil every 100 hours or every season thereafter If running this unit under dirty or dusty conditions or in extremely hot weather change the oil more often CAUTION Hot oil may cause burns Allow engine to cool before draining oil Avoid prolonged or repeated skin exposure with used oil Thoroughly wash exposed areas with soap Use the following instructions to change the oil after the engine cools down lean area around oil drain plug Remove oil drain plug from engine and oil fill plug to drain oil completely into a suitable container e When oil has completely drained instal
56. aces externes du g n rateur V rifier que les fentes de refroidissement et les orifices du g n rateur sont ouverts et non obstru s e Stocker l unit dans un endroit propre et sec 6 AUTRES CONSEILS DE STOCKAGE Ne pas stocker l essence d une saison sur l autre Remplacer le bidon d essence s il commence rouiller De la rouille et ou de la salet dans l essence entraineront des probl mes dans le carburateur et le circuit de carburant Si cela est possible stocker l unit l int rieur et la recouvrir afin de la prot ger de la salet et de la poussi re S ASSURER DE VIDER LE R SERVOIR D ESSENCE e S il n est pas possible de vider le r servoir d essence et que l unit est rang e pendant une longue p riode ajouter un stabilisateur d essence disponible dans le commerce l essence afin d augmenter la dur e de vie de l essence Couvrir l unit avec une protection adapt e ne retenant pas l humidit ADANGER NE JAMAIS couvrir le g n rateur alors que le moteur et la zone du pot d chappement sont chauds 53 4 1 GUIDE DE D PANNAGE PROBL ME Le moteur tourne mais aucun courant alternatif n est produit Le moteur fonctionne bien mais conna t des d faillances lorsque des charges sont branch es Le moteur ne d marre pas ou d marre et conna t des d faillances Le moteur s arr te pendant le fonctionnement coups ou d clin du moteur 54 1 Disjoncteur est ouver
57. ado o reemplazado por Generac de acuerdo a la Subsecci n 4 m s abajo Cualquier parte as reparada o reemplazada bajo la garant a ECS deber ser garantizada por el resto del periodo de garant a ECS 2 Cualquier parte garantizada que est programada s lo para inspecci n regular como se especifica en el Manual del propietario ser garantizada en el periodo de garant a ECS Una declaraci n en el manual del propietario a efecto de reparar o reemplazar seg n sea necesario no reducir el periodo de garant a ECS Cualquier parte as reparada o reemplazada bajo la garant a ECS deber ser garantizada por el resto del periodo de garant a ECS 3 Cualquier parte garantizada que est programada para reemplazo seg n lo requiera el mantenimiento en el Manual del Propietario deber ser garantizado por el periodo de tiempo antes del primer punto de reemplazo programado para esa parte Si la parte falla antes del primer reemplazo programado la parte ser reparada o reemplazada por Generac de acuerdo a la Subsecci n 4 m s abajo Cualquier parte relacionada a las emisiones as reparada o reemplazada bajo la garant a ECS ser garantizada por el resto del periodo antes del primer punto de reemplazo programado para aquella parte 4 La reparaci n o reemplazo de cualquier parte garantizada relacionada a las emisiones bajo esta garant a ECS deber realizarse sin costo alguno para el propietario en un centro de servicio de garant a autori
58. ador El generador DEBE ser operado en exteriores Este sistema de escape debe tener un apropiado mantenimiento No haga nada que pueda poner en peligro la seguridad del escape 0 que no cumpla con alg n c digo local o est ndar Siempre use una alarma de mon xido de carbono operada con bater as en los interiores instalada de acuerdo a las instrucciones del fabricante Si empieza a sentirse mal mareado o d bil luego de que el generador est en funcionamiento busque aire fresco INMEDIATAMENTE Vaya al m dico ya que podr a tener envenenamiento por mon xido de carbono 22 PELIGROS EL CTRICOS El generador produce alto voltaje peligroso durante la operaci n Evite el contacto con cables pelados terminales conexiones etc mientras la unidad est funcionando a n con equipo conectado al generador Aseg rese que todas las cubiertas protecciones y barreras apropiadas se encuentren en su lugar antes de operar el generador Nunca manipule ning n cable el ctrico ni dispositivo mientras est de pie sobre agua con los pies descalzos o con las manos o pies h medos PUEDE HABER UNA DESCARGA EL CTRICA COMO RESULTADO El C digo El ctrico Nacional NEC requiere que el marco y las partes externas que son conductores el ctricos est n conectadas apropiadamente a una conexi n a tierra aprobada Los c digos el ctricos locales pueden asimismo requerir una apropiada conexi n a tierra del generador Consulte con un electricista l
59. ar un motor frio Tanque de combustible Revise la capacidad del tanque en las especificaciones del generador Leng eta de tierra Conecte el generador a una conexi n tierra aprobada desde aqu Vea Conectando el generador a tierra para mayores detalles Interruptor de funcionamiento parada Controla la operaci n del generador modelos s lo de arranque de tiro Interruptor de arranque Se usa para arrancar el motor desde el motor arrancador modelos de arranque el ctrico solamente Silenciador Silencia el motor Figura 2 Panel de control Manubrio Pivotea y se retracta para almacenarse Presione los botones con resorte para mover los manubrios Tapa de gasolina Ubicaci n de llenado de combustible Medidor de combustible Muestra el nivel de combustible en el tanque Llenado de aceite Agregue aceite aqu Arranque de culata Use para arrancar el motor manualmente Cierre de combustible V lvula entre el tanque de combustible y el carburador Entrada del cargador de bater a Este recept culo permite recargar la bater a de almacenamiento de 12 voltios proporcionada con el conector adaptador de 12 voltios que se incluye en la caja de accesorios Detr s de la entrada del cargador de bater as se encuentra un fusible en l nea de 1 5 amperios que est dentro del panel de control para proteger la bater a s lo arranque el ctrico Bater a
60. ario del generador usted es responsable de completar todos los mantenimientos requeridos tal como se lista en el manual del propietario proporcionado por la f brica Para prop sitos de garant a Generac recomienda que usted conserve todos los recibos que cubren el mantenimiento de su generador pero Generac no puede rehusar la garant a s lo debido a la falta de recibos Como propietario del generador usted deber ser consciente de que Generac puede negar cualquier y o todas las coberturas y responsabilidades de la garant a si su generador o una parte o componente del mismo ha fallado debido al abuso negligencia mantenimiento inapropiado o modificaciones no aprobadas o el uso de repuestos falsos o del mercado negro no fabricados suministrados o aprobados por Generac Usted es responsable de contactar a un concesionario autorizado de garant a de Generac tan pronto se presente el problema Las reparaciones de garant a deber n completarse en un tiempo razonable sin exceder los 30 d as El servicio de garant a puede arreglarse contactando ya sea a su concesionario de venta o a un concesionario de servicio de garant a autorizado de Generac Para ubicar al concesionario de servicio de garant a autorizado de Generac m s cercano a usted llame a nuestro n mero gratuito 1 800 333 1322 NOTA IMPORTANTE Esta declaraci n de garant a explica sus derechos y obligaciones bajo la Garant a del sistema de control de emisiones ECS Warranty
61. ateur ne doivent pas tre obstru es par la neige les feuilles ou tout autre corps tranger V rifier r guli rement que le g n rateur est propre et nettoyer la poussi re les salet s l huile l eau ou les autres corps trangers qui sont visibles sur sa surface ext rieure ATTENTION Ne jamais ins rer d objet ou d outil dans les fentes de refroidissement m me si le moteur ne fonctionne pas REMARQUE NE PAS utiliser un tuyau d arrosage pour nettoyer le g n rateur L eau peut entrer dans le syst me de carburant du moteur et causer des probl mes En outre si l eau entre dans le g n rateur par les fentes de refroidissement de l eau restera dans les vides et les crevasses du bobinage d isolement du rotor et du stator L accumulation d eau et de salet s sur les bobinages internes du g n rateur diminuera potentiellement la r sistance d isolement de ces bobinages 3 3 2 NETTOYAGE DU G N RATEUR e Utiliser un chiffon humide pour le nettoyage des surfaces externes e est possible d utilise une brosse douce en poils pour d coller les agglutinements de salet s d huile etc e Un aspirateur pourra tre utilis pour r cup rer les salet s et les d bris e Un air projet avec une faible pression inf rieur 25 livres par pouce carr pourra tre utilis pour souffler la salet Inspecter les fentes de refroidissement et les orifices du g n rateur Ces orifices doivent tre propres et non obstru
62. ational codes and regulations Study all safety warnings in this manual and on the product carefully Become familiar with this manual and the unit before use The manufacturer cannot anticipate every possible circumstance that might involve a hazard The warnings in this manual and on tags and decals affixed to the unit are therefore not all inclusive If using a procedure work method or operating technique that the manufacturer does not specifically recommend ensure that it is safe for others Also make sure the procedure work method or operating technique utilized does not render the generator unsafe THE INFORMATION CONTAINED HEREIN WAS BASED ON MACHINES IN PRODUCTION AT THE TIME OF PUBLICATION GENERAC RESERVES THE RIGHT TO MODIFY THIS MANUAL AT ANY TIME SAFETY RULES Throughout this publication and on tags and decals affixed to the generator DANGER WARNING CAUTION and NOTE blocks are used to alert personnel to special instructions about a particular operation that may be hazardous if performed incorrectly or carelessly Observe them carefully Their definitions are as follows DANGER INDICATES A HAZARDOUS SITUATION OR ACTION WHICH IF NOT AVOIDED WILL RESULT IN DEATH OR SERIOUS INJURY WARNING Indicates a hazardous situation or action which if not avoided could result in death or serious injury 4 CAUTION Indicates a hazardous situation or action which if not avoided could result in
63. aud et entrainer un INCENDIE ou une EXPLOSION Ne jamais stocker le g n rateur avec le r servoir rempli de carburant tant donn que les vapeurs d essence pourraient atteindre une flamme ouverte des tincelles ou une veilleuse comme il y en a sur une chaudi re un chauffe eau ou sur un s che linge Cela peut entrainer un INCENDIE ou une EXPLOSION Laisser l unit compl tement refroidir avant le stockage Nettoyer imm diatement toute claboussure de carburant ou d huile S assurer qu aucune mati re combustible ne reste sur ou proximit du g n rateur Garder l espace environnant du g n rateur propre et sans d bris et garder un jeu de cinq 5 pieds sur tous les c t s afin de permettre une a ration adapt e du g n rateur R gles de s curit pas ins rer d objet dans les fentes de refroidissement de l unit pas faire fonctionner le g n rateur si des dispositifs lectriques N DE MOD LE branch s surchauffent si la puissance lectrique est perdue si le moteur ou le g n rateur fait des tincelles si des flammes ou de la N DE S RIE fum e sont d tect es alors que l unit fonctionne Garder un extincteur proximit du g n rateur tout moment Emplacement ID de l unit INDEX DES NORMES En l absence de normes codes r glementations et lois applicables les informations publi es indiqu es ci dessous peuvent servir de directive pour le fonctionnement de
64. brio e 1 litro de aceite SAE 30 e 1 Pata de marco e 2 Ruedas que no se bajan 1 Cargador de bater a s lo arranque el ctrico e 1 Bolsa de hardware conteniendo lo siguiente e 2 Patas de goma e 2 pernos 8 Largos 2 pasadores de eje de 1 2 e 2 pernos 8 cortos 2 Chavetas e 2 tuercas Acom M8 e 2 arandelas planas de 1 2 4tuercas M8 de reborde hexagonales 2 pernos cortos e 2arandelas de cierre e 2 tuercas de reborde arranque el ctrico solamente 1 2 ENSAMBLE generador requiere alg n ensamble antes de usarse Si se presentan problemas al ensamblar el generador por favor llame a la Generator Helpline al 1 888 77LOWES 1 2 1 ENSAMBLAJE DEL KIT DE ACCESORIOS Las ruedas est n dise adas en la unidad para mejorar la portabilidad del generador Usted necesitar las siguientes herramientas para instalar apropiadamente el juego de accesorios Alicates de cig e a Llave de crique y boca de 13mm 1 2 Llave de boca de 13mm 1 2 NOTA Las ruedas no est n dise adas para su uso en las pistas 1 Consulte la figura 1 e instale las ruedas como sigue Deslice los pasadores del eje a trav s de las ruedas arandela plana de 1 2 y soporte de las ruedas en el marco nserte el pasador de chaveta a trav s del pasador del eje luego doble las pesta as de los pasadores hacia afuera para mantenerlos en el lugar 2 Consulte la figura 1 e instale la pata del marco y los parachoques de
65. cet quipement Toujours se reporter la derni re r vision disponible pour les normes indiqu es 1 70 HANDBOOK OF NATIONAL ELECTRIC CODE Manuel NFPA du code lectrique national 2 Article X NATIONAL BUILDING CODE Code de construction national disponible aupr s de l American Insurance Association 85 John Street New York N Y 10038 3 AGRICULTURAL WIRING HANDBOOK Manuel de c blage agricole disponible aupr s du Food and Energy Council 909 University Avenue Columbia MO 65201 4 ASAE EP 3634 INSTALLATION AND MAINTENANCE OF FARM STANDBY ELECTRICAL SYSTEMS Installation et maintenance des syst mes lectriques de secours pour les fermes disponible aupr s de l American Society of Agricultural Engineers 2950 Niles Road St Joseph MI 49085 MOD LE D TIQUETTE AVERTISSEMENT PROPOSITION 65 CALIFORNIE L chappement du moteur et certains de ses constituants sont susceptibles selon l Etat de Californie d entra ner des cancers des malformations cong nitales ou pouvant tre nocifs pour le syst me reproductif AVERTISSEMENT PROPOSITION 65 CALIFORNIE Ce produit contient ou met des produits chimiques susceptibles selon l Etat de Californie d entra ner des cancers des malformations cong nitales ou autres maladies pouvant tre nocives pour le syst me reproductif 43 Informations g n rales 1 1 D BALLAGE Retirer tous les l ments d emballage Enl
66. das las conexiones est n seguras Deslice las botas de goma sobre los terminales y la ferreter a de conexi n NOTA Si la bater a no puede arrancar el motor c rguela con el cargador de 12 voltios incluido en la caja de accesorios ver detalles en la secci n Cargando una bater a 2 1 CONOZCA EL GENERADOR Lea el manual del propietario y las reglas de seguridad antes de operar este generador Compare el generador con las figuras de la 2 a la 4 para familiarizarse con las ubicaciones de los diversos controles y ajustes Guarde este manual para referencias futuras 1 Recept culo d plex de 120 Volt AC 20 Amp Proporciona energ a el ctrica para la operaci n de cargas de iluminaci n el ctrica aparatos herramientas o motores de 120 Volt AC 20 Amp monof sicos de 60 Hz 2 Recept culo con cierre de 120 240 Volt AC 30 Amp Proporciona energ a el ctrica para la operaci n de cargas de iluminaci n el ctrica aparatos herramientas o motores de 120 y o 240 Volt AC 30 Amp monof sicos de 60 Hz 3 Interruptores de circuito AC Cada recept culo est provisto con un interruptor de circuito de presionar para reiniciar con el fin de proteger al generador contra sobrecargas el ctricas 4 Drenaje de aceite Usar para drenar el aceite del motor 5 Filtro de aire Filtra el aire de ingreso al motor 9A 10 11 12 13 14 15 16 17 18 19 Palanca de choke Se le usa al arranc
67. de 30 2 4 C MO USAR ESTE GENERADOR Si hay alg n problema al operar el generador por favor llame a la Generator Helpline al 1 888 436 3722 PELIGRO El uso de un generador en interiores PUEDE MATARLE EN MINUTOS El escape del generador contiene mon xido de carbono Este es un veneno invisible y sin olor MEA NUNCA lo use dentro de una casal selo s lo EN EXTERIORES o garaje AUN SI las puertas y las ventanas est n abiertas y lejos de ventanas puertas y ductos de ventilaci n 2 4 1 CONEXI N A TIERRA DEL GENERADOR El C digo El ctrico Nacional requiere que el marco y las partes externas de este generador que son conductores el ctricos est n conectadas en forma apropiada a una conexi n a tierra aprobada figura 7 Los c digos el ctricos locales pueden asimismo requerir una apropiada conexi n a tierra de la unidad Para este prop sito el conectar un conductor de cobre 10 AWG trenzado la tuerca de tierra y a una vara de bronce o cobre de tierra electrodo proporciona una protecci n adecuada contra descargas el ctricas Sin embargo los c digos locales pueden variar ampliamente Consulte con un electricista local los requerimientos de conexi n a tierra para su rea Operaci n Figura 7 Conexi n a tierra del generador NOTA Todas las cifras son aproximadas Vea la etiqueta de datos los aparatos para saber los requerimientos de potencia 2 6 GU A DE REFERENCIA DE P
68. duraci n de la vida del motor El sistema de control de emisiones de este generador consiste en lo siguiente Sistema de inducci n de aire Sistema de ignici n Tuber a distribuidor de entrada Buj a Limpiador de aire Bobina de arranque Sistema de escape e Sistema de combustible Distribuidor de escape Carburador Silenciador El per odo de cumplimiento de emisiones mencionado en la etiqueta de cumplimiento de emisiones indica el n mero de horas de operaci n para las que el motor ha demostrado cumplir los requerimientos de emisi n de la EPA 3 3 RECOMENDACIONES GENERALES La garant a del generador no cubre tems que hayan sido objeto de abuso o negligencia del operador Para recibir el valor total de la garant a el operador debe hacer el mantenimiento del generador tal como se instruye en este manual Se necesitar hacer algunos ajustes peri dicamente para mantener apropiadamente este generador Todos los ajustes en la secci n de Mantenimiento de este manual deber n hacerse al menos una vez en cada cambio de estaci n Siga los requerimientos del Programa de mantenimiento NOTA Una vez al a io reemplace las buj as y el filtro de aire Buj as nuevas y filtro de aire limpio aseguran una apropiada mezcla de aire combustible y ayudan a que el motor funcione mejor y dure m s 9 3 1 MANTENIMIENTO DEL GENERADOR mantenimiento del generador consiste en mantener a la unidad limpia
69. e lectrique 50 40 Maintenance 50 3 1 Programme de 50 3 2 Caract ristiques techniques des produits 50 3 2 1 Caract ristiques techniques du g n rateur 50 3 2 2 Caract ristiques techniques du moteur 50 3 2 3 Informations relatives aux missions 51 3 3 Recommandations g n rales 51 3 3 1 Maintenance du 51 3 3 2 Nettoyage du g n rateur 51 3 8 3 Maintenance du 51 3 8 4 V rification du niveau d huile 51 3 8 5 Changement de l huile 51 3 3 6 Remplacement des bougies d allumage 52 3 3 7 Remplacement de la batterie 52 3 4 Entretien du filtre 52 3 5 Stockage long terme 52 3 6 Autres conseils de stockage 53 D pannage 54 4 1 Guide de 54 Remarques 55 Caramel 56 Introduction INTRODUCTION Nous vous remercions d avoir achet ce mod le fabri
70. e almacene la unidad en interiores y c brala para protegerla del polvo y la suciedad ASEG RESE DE VACIAR EL TANQUE DE COMBUSTIBLE Si no fuera pr ctico vaciar el tanque de combustible y la unidad tiene que almacenarse por un tiempo use un estabilizador de combustible comercial disponible y a dalo a la gasolina para prolongar la vida de esta Cubra la unidad con una cubierta protectora adecuada que no retenga humedad PELIGRO NUNCA cubra el generador mientras las reas del motor y el escape est n calientes 33 Detecci n de fallas 4 1 GU A DE DETECCI N DE PROBLEMAS PROBLEMA El motor est funcionando pero no hay salida de AC disponible El motor funciona bien pero se siente sobrecargado cuando las cargas est n conectadas El motor no arranca o arranca pero funciona en forma spera El motor se apaga durante la operaci n El motor se pierde o tartamudea 34 1 El interruptor de circuito est abierto 2 Pobre conexi n o cable defectuoso 3 El dispositivo conectado est mal 4 Falla en el generador 1 Cortocircuito en la carga conectada 2 El generador est sobrecargado 3 La velocidad del motor es muy lenta 4 Circuito del generador en corto El cierre de combustible est en OFF Filtro de aire sucio Falta gasolina Gasolina pasada El cable de la buj a no est conectado a esta Buj as en mal estado Agua en la gasolina Over choking 9 Nivel de aceite bajo
71. e seront support s et pay s l avance par l acqu reur le propri taire Cette garantie ne s applique qu aux g n rateurs portables de la s rie GP et n est pas transf rable par l acqu reur d origine Il est conseill de conserver les preuves d achat Si vous ne fournissez pas de preuve de la date d achat d origine la date d envoi du produit par son fabricant servira d terminer la p riode de garantie PROGRAMME DE GARANTIE Les applications des clients sont garanties pendant deux 2 ans Les applications commerciales et de location sont garanties pendant un 1 an ou 1 000 heures maximum la premi re des deux dates APPLICATION DES CLIENTS ANN E UNE couverture 100 cent pour cent pour la main d uvre et la les pi ce s il est n cessaire de pr senter une preuve d achat et de maintenance Tous les composants ANN E DEUX couverture 100 cent pour cent sur la les pi ce s il est n cessaire de pr senter une preuve d achat et de maintenance Tous les composants APPLICATIONS COMMERCIALES DE LOCATION ANN E UNE couverture 100 cent pour cent ou 1 000 heures quelque soit le premier v nement qui survient pour la main d uvre et la les pi ce s il est n cessaire de pr senter une preuve d achat et de maintenance Tous les composants INTERNATIONAL ANN E UNE ou 1000 heures selon la premi re occurrence couverture compl te limit e pour la main d uvre et les pi ces list
72. e valeur nominale des volts fois la valeur nominale des amp res afin de Radio 50 200 d terminer les watts volts x amp res watts R frig 700 Certains moteurs lectriques tels que ceux induction n cessitent Cocotte mijoteuse N 200 environ trois fois plus de watts d alimentation pour le d marrage CO re que pour le fonctionnement Cette surtension d alimentation dure Pompe immerg e 1 5 HP 2 800 seulement quelques secondes lors du d marrage des moteurs en Pompe immerg e 1 HP 2 000 question S assurer de laisser un wattage de d marrage lev lors du immerg e 0 5 1 500 choix des dispositifs lectriques pour brancher le g n rateur Pompe de Vidange o hora E ee hh sis 800 1 050 1 Calculer les watts n cessaires pour d marrer le moteur le plus Scie circulaire table 10 po 1 750 2 000 grand 200 500 2 Ajouter ce chiffre les watts de fonctionnement de toutes les autres Enr 1 000 1 650 charges branch es Coupe mauvaises herbes 500 Le Guide de r f rence de wattage sert d terminer combien d l ments le g n rateur peut faire fonctionner en m me temps Laisser 3 fois les watts indiqu s pour le d marrage de ces dispositifs 47 Fonctionnement 2 7 AVANT LE D MARRAGE DU G
73. e du kit d accessoires 44 1 2 2 Branchement des c bles de batterie d marrage lectrique uniquement 44 Fonctionnement 44 2 1 Bien connaitre le 44 2 2 A 46 2 3 Cordons et 1 46 2 3 1 Prise double 120 V c a 20 46 2 3 2 Prise 120 240 V 30 46 2 4 Utilisation du 46 2 41 Mise la terre du 46 2 4 2 Branchement des charges lectriques 47 2 5 Ne pas surcharger le 47 2 6 Guide de r f rence de 47 2 7 Avant le d marrage du 48 2 7 1 de l huile de moteur 48 2 7 2 Ajout de l essence 48 2 8 D marrage des moteurs d marrage manuel 48 2 9 D marrage des moteurs d marrage lectrique 49 2 10 Arr t du moteur A 49 2 11 Syst me d arr t de bas niveau d huile 49 2 11 1 D tection de bas niveau d huile 49 2 12 Chargement de la batterie unit s d marrag
74. e o donde el servicio p blico de energ a no exista normalmente Una vez que el generador ha experimentado uso comercial o de alquiler se le considerar en adelante un generador no para uso del consumidor para prop sitos de esta garant a Todos los gastos por garant a est n sujetos a las condiciones definidas en el Manual de pol tica de servicio de Generac ESTA GARANT A NO SE APLICAR A LO SIGUIENTE Generadores port tiles construidos por Generac antes de Junio de 2010 Generadores port tiles de Generac que utilizan repuestos que no son de Generac Costos de mantenimiento normal y ajustes Fallas causadas por combustibles o aceites contaminados o la falta de niveles apropiados Reparaciones o diagn sticos realizados por individuos diferentes a los concesionarios autorizados por Generac que no est n autorizados por escrito por Generac Power Systems Fallas debido a pero no limit ndose a el uso y desgaste normal accidente mal uso abuso negligencia o uso inapropiado Como todo dispositivo mec nico los motores Generac necesitan servicio y repuestos peri dicamente para funcionar como est n dise ados Esta garant a no cubre reparaciones cuando el uso normal ha agotado la vida til de una parte o motor Las fallas causadas por cualquier causa externa o acto de Dios como colisi n robo vandalismo disturbios o guerra holocausto nuclear incendio congelamiento electricidad atmos f rica terremoto tormentas
75. ee Pad 1200 Edge TIMMEN Lie to 500 Electric Blanketi cocos tmr nes semaines 400 Electric di 1200 Electric Range per element 1500 Electric Skillet 1250 A se 700 Furnace Fan 3 5 875 Garage Door Opener 500 to 750 1200 250 to 1100 H dde TIMMEN srs eect ced ete sos eue dus eee 450 Impact WENCH in suisse ses 500 Jn T 1200 ir gii ELEM 800 Lawn Mower 2 ia adv eens a evene 1200 Light BUID ie entr deinde et died eR 100 Microwave 700 to 1000 usnm 1100 Oil Burner on Furnace eR re 300 Oil Fired Space Heater 140 000 Btu 400 Oil Fired Space Heater 85 000 Btu 225 Oil Fired Space Heater 30 000 Btu 150 Paint Sprayer Airless 1 3 600 Paint Sprayer Airless handheld 150 Radio reper Pin Pb ERIT e EE 50 to 200 hRefrigerator 700 Slow Cooker 200 Submersible Pump 1 1 2 2800 Submersible Pump 1 2000 Submersible Pump 1 2
76. en etr reet Pistola el ctrica de clavos Conecte y encienda las cargas el ctricas monotisicas de 1200240 nn nnn ao voltios y 60 Hz deseadas Congeladora 700 e Sume la todas las a T Ventilador de chimenea 3 5 HP AA 875 ser n conectadas a la vez Este total no deber ser mayor que a la WR io UIDES NUITS UE E capacidad de potencia y corriente del generador o b la capacidad 2 a 2 SURINAM ee cE uU 2 nominal del interruptor del circuito que suministra la energ a Vea ee sobrecargue el generador Taladro de mano de 250 a 1100 Cortador de SETOS eresien monnaies initi i 450 2 5 NO SOBRECARGUE EL GENERADOR juu e e Sobrecargar un generador en exceso de su capacidad de potencia nominal ne dau 800 puede traer como resultado da os al generador los dispositivos Cortadora de c sped 1200 el ctricos conectados Observe lo siguiente para evitar sobrecargar la Bombilla de UZ 100 unidad Horno de microondas de 700 a 1000 e Sume el total de potencia de todos los dispositivos el ctricos Enfriador de leche usuris cette 1100 conectarse a la vez Este total NO deber ser mayor que la capacidad Quemador de aceite sobre 300 de potencia del generador Calentador de chispa de aceite 140 000 400 a potencia nominal de las luces puede leerse en
77. enamiento y manipulaci n de gasolina No sobrecargue el tanque de combustible Deje siempre espacio para la expansi n del combustible Si el tanque est sobrecargado el combustible puede desparramarse sobre el motor caliente y causar un INCENDIO o una EXPLOSION Nunca almacene el generador con combustible en el tanque donde los vapores de la gasolina pueden alcanzar llamas abiertas chispas o fuegos piloto como en una chimenea calentador de agua o secador de ropa Puede generarse un INCENDIO o una EXPLOSI N Deje enfriar la unidad completamente antes de almacenarse Limpie cualquier derrame de combustible o aceite inmediatamente Aseg rese de que no haya materiales combustible dejados sobre o cerca del generador Mantenga el rea alrededor del generador limpia y libre de residuos y conserve una claridad de cinco 5 pies a todos los lados para permitir una ventilaci n apropiada para el generador Reglas de seguridad No inserte objetos a trav s de las ranuras de enfriamiento de No opere el generador si los dispositivos el ctricos conectados sobrecalientan si la salida el ctrica se pierde si el motor o el DE SERIE generador bota chispas o se observa humo mientras la unidad Tenga un extinguidor cerca al generador en todo momento Ubicaci n del IP de la unidad est funcionando NDICE DE EST NDARES En ausencia de los est ndares c digos regulaciones o leyes pertinentes la informaci n publicada listada
78. ence 0H8902 R vision A 19 05 10 Manuel r f rence 0H9060 R v B 20 08 10 Imprim en Chine
79. er le r servoir d essence et le remplir avec de l essence nouvelle 5 Brancher le fil la bougie d allumage Remplacer la bougie d allumage Vidanger le r servoir d essence et le remplir avec de l essence nouvelle Placer le levier d trangleur sur la position No Choke Aucun trangleur 9 Remplir le carter jusqu au niveau n cessaire 10 Contacter un centre d entretien agr 11 Contacter un centre d entretien agr 12 Contacter un centre d entretien agr 1 Remplir le r servoir d essence 2 Remplir le carter jusqu au niveau n cessaire 3 Contacter un centre d entretien agr 1 Diminuer la charge voir la section Ne pas Surcharger le g n rateur 2 Nettoyer ou remplacer le filtre air 3 Contacter un centre d entretien agr 1 Placer le levier d trangleur mi chemin jusqu ce que le moteur fonctionne correctement 2 Contacter un centre d entretien agr Remarques 55 LA GARANTIE F D RALE DU CONTR LE DES MISSIONS VOS DROITS ET OBLIGATIONS DE GARANTIE L Agence pour la Protection de l Environnement am ricaine ci apr s d nomm e EPA et la soci t Generac Power Systems Inc ci apr s d nomm e Generac sont heureux de vous expliquer ce qu est la garantie de votre nouvel quipement 2008 et ult rieur Le nouvel quipement utilise des petits moteurs allumage command doivent tre con us construits et quip s dans le respect des norm
80. ereporter au Sch ma 1 et installer les roues comme suit Faire glisser les axes d essieu travers la roue la rondelle plate de 0 5 po et le support de la roue sur le b ti ns rer la goupille fendue travers l axe d essieu puis plier les languettes des goupilles fendues vers l ext rieur afin de les fixer 2 Se reporter au Sch ma 1 et installer le pied du b ti et les butoirs en caoutchouc comme indiqu Faire glisser les axes des butoirs en caoutchouc travers le pied du b ti puis installer les crous collet de blocage Faire glisser les boulons t te hexagonale travers les rondelles plates travers les trous dans le longeron de cadre de ch ssis Faire glisser le pied du sur les boulons t te hexagonale puis installer les crous collet de blocage 3 Sereporter au Sch ma 1 et installer la poign e comme indiqu Faire glisser les boulons longs travers le support de poign e et la poign e puis installer les crous hexagonaux 44 Sch ma 1 Roue et poign e CROU BORGNE M8 POIGN E nu 7 2 X AXE D ESSIEU Ay 2 X ROUE N X RONDELLE PLATE DE 0 5 PO PIED DU B TI 2 X GOUPILLE FENDUE 2XPIED EN CAOUTCHOUC 4 X CROU M8 1 2 2 BRANCHEMENT DES C BLES DE BATTERIE DEMARRAGE ELECTRIQUE UNIQUEMENT L unit a t envoy e avec les c bles de batterie d branch s Pour brancher la batterie voir Sch ma 13 pour les informations relatives au branchement
81. eriod any emission related part on your equipment is found to be defective in materials or workmanship repairs or replacement will be performed by a Generac Authorized Warranty Service Dealer OWNER S WARRANTY RESPONSIBILITIES As the generator owner you are responsible for the completion of all required maintenance as listed in your factory supplied Owner s Manual For warranty purposes Generac recommends that you retain all receipts covering maintenance on your generator but Generac cannot deny warranty solely due to the lack of receipts As the generator owner you should be aware that Generac may deny any and or all warranty coverage or responsibility if your generator or a part component thereof has failed due to abuse neglect improper maintenance or unapproved modifications or the use of counterfeit and or grey market parts not made supplied or approved by Generac You are responsible for contacting a Generac Authorized Warranty Dealer as soon as a problem occurs The warranty repairs should be completed in a reasonable amount of time not to exceed 30 days Warranty service can be arranged by contacting either your selling dealer or a Generac Authorized Warranty Service Dealer To locate the Generac Authorized Warranty Service Dealer nearest you call our toll free number 1 800 333 1322 IMPORTANT NOTE This warranty statement explains your rights and obligations under the Emission Control System Warranty ECS Warranty which i
82. erly maintain the generator All adjustments in the Maintenance section of this manual should be made at least once each season Follow the requirements in the Maintenance Schedule NOTE Once a year replace the spark plug and replace the air filter A new spark plug and clean air filter assure proper fuel air mixture and help the engine run better and last longer 3 3 1 GENERATOR MAINTENANCE Generator maintenance consists of keeping the unit clean and dry Operate and store the unit in a clean dry environment where it will not be exposed to excessive dust dirt moisture or any corrosive vapors Cooling air slots in the generator must not become clogged with snow leaves or any other foreign material Check the cleanliness of the generator frequently and clean when dust dirt oil moisture or other foreign substances are visible on its exterior surface A CAUTION Never insert any object or tool through the air cooling slots even if the engine is not running NOTE DO NOT use a garden hose to clean generator Water can enter the engine fuel system and cause problems In addition if water enters the generator through cooling air slots some water will be retained in voids and crevices of the rotor and stator winding insulation Water and dirt buildup on the generator internal windings will eventually decrease the insulation resistance of these windings 9 3 2 TO CLEAN THE GENERATOR Use a damp cloth to wipe exterior surf
83. es nationales rigoureuses en mati re de pollution pour le gouvernement f d ral Generac garantira le syst me de contr le des missions de votre g n rateur pour les p riodes indiqu es ci apr s en l absence d acte abusif de n gligence de modification non approuv e ou de maintenance inadapt e de votre quipement Votre syst me de contr le des missions pourra comprendre certaines pi ces telles que le carburateur le syst me d allumage le syst me de carburant le pot catalytique et les autres composants relatifs aux missions le cas ch ant COUVERTURE DE GARANTIE DU FABRICANT Ce syst me de contr le des missions est garanti pendant une dur e de deux ans Si un composant ou syst me de votre quipement relatif aux missions comporte une pi ce d fectueuse ou pr sente un d faut de fabrication pendant la dur e de la garantie les r parations ou remplacements de pi ces seront effectu s par un d positaire d entretien de garantie agr par Generac RESPONSABILIT S DE GARANTIE DU PROPRIETAIRE En tant que propri taire du g n rateur vous tes responsable de la r alisation de toute la maintenance n cessaire telle que list e dans le manuel d entretien qui vous a t remis par l usine Aux fins de la garantie Generac vous recommande de conserver tous les re us relatifs la maintenance effectu e sur votre g n rateur mais Generac ne peut pas refuser la garantie uniquement en raison de la non pr sentation
84. esh air IMMEDIATELY See a doctor as you could have carbon monoxide poisoning ELECTRICAL HAZARDS The generator produces dangerously high voltage when in operation Avoid contact with bare wires terminals connections etc while the unit is running even on equipment connected to the generator Ensure all appropriate covers guards and barriers are in place before operating the generator Never handle any kind of electrical cord or device while standing in water while barefoot or while hands or feet are wet DANGEROUS ELECTRICAL SHOCK MAY RESULT The National Electric Code NEC requires the frame and external electrically conductive parts of the generator be properly connected to an approved earth ground Local electrical codes may also require proper grounding of the generator Consult with a local electrician for grounding requirements in the area Use a ground fault circuit interrupter in any damp or highly conductive area such as metal decking or steel work Do not use worn bare frayed or otherwise damaged electrical cord sets with the generator Before performing any maintenance on the generator disconnect the engine starting battery if equipped to prevent accidental start up Disconnect the cable from the battery post indicated by a NEGATIVE NEG or first Reconnect that cable last In case of accident caused by electric shock immediately shut down the source of electrical power this is not possible attempt to f
85. etario original Guarde su comprobante de compra Si usted no proporciona una prueba de la fecha de la compra inicial se usar la fecha de embarque del producto del fabricante para determinar el periodo de garant a PROGRAMACI N DE GARANT A Las aplicaciones para consumidor est n garantizadas por 2 a os Las aplicaciones comerciales y de alquiler est n garantizadas por un 1 a o o 1000 horas como m ximo lo que llegue primero APLICACI N PARA CONSUMIDOR O UNO 100 cien por ciento de cobertura en mano de obra y repuestos se requiere comprobante de compra y mantenimiento Todos los componentes O DOS 100 cien por ciento de cobertura en repuestos se requiere comprobante de compra y mantenimiento Todos los componentes e gt gt gt PLICACI N COMERCIAL DE ALQUILER NO UNO 100 cien por ciento O 1 000 horas lo que ocurra primero de cobertura en mano de obra y repuestos se requiere comprobante de compra y mantenimiento Todos los componentes gt NTERNACIONAL A O UNO o 1000 horas lo que ocurra primero Cobertura amplia limitada en mano de obra y partes listadas TODOS LOS COMPONENTES NOTA Para el prop sito de esta garant a uso de consumidor significa uso personal en casa residencial o recreacional por el comprador original La garant a no aplica a unidades usadas para Fuente Primaria de Energ a en lugar del servicio p blico donde el servicio p blico se encuentre present
86. eur ou dans les dispositifs lectriques branch s La bonne mise 1 750 la terre aide galement dissiper l lectricit statique qui s accumule Compresseur 1 HP 2 000 souvent dans les dispositifs non mis la terre Compresseur 0 75 1800 242 BRANCHEMENT DES CHARGES LECTRIQUES NE PAS brancher des charges de 240 V des prises de 120 V NE PAS D shumidificateur 650 brancher des charges triphas es au g n rateur NE PAS brancher des Ponceuse disque 9 po 1 200 charges de 50 Hz au g n rateur Coupe bordures 500 e Laisser le moteur se stabiliser et chauffer pendant quelques minutes Couverture chauffante A pb 400 apr s le d marrage Cloueuse lectrique 1 200 e Brancher et mettre sous tension les charges lectriques monophas es Cuisini re lectrique par l ment 1 500 souhait es de 120 ou 240 V c a 60 Hz lectrique guerre 1 250 e Ajouter les watts ou amp res nominaux de toutes les charges Freezer ES 700 brancher m me temps Ce total ne doit pas d passer a la Ventilateur de chaudi re 0 6 HP 875 capacit nominale de wattage amp rage du g n rateur ou b la valeur Ouvre parte d 500 750 nom
87. ever la boite d accessoires s par e e Retirer le g n rateur du carton 1 1 1 BO TE D ACCESSOIRES V rifier le contenu de la bo te Si des pi ces sont absentes ou endommag es merci de localiser un d positaire agr au 1 888 436 3722 e 1 Manuel d entretien e 1 Poign e 1 Litre d huile SAE 30 e 1 Pied du b ti e 2 Roues jamais plates e 1 Chargeurdebatterie d marrage lectrique uniquement e 1 Sac de mat riel contenant ce qui suit 2 Pieds en caoutchouc 2 Boulons 8 longs 2 Axes d essieu de 0 5 po 2 Boulons M8 courts 2 Goupilles fendues 2 Ecrous borgnes 8 2 Rondelles plates de 0 5 po 4 Ecrous collet hexagonal M8 2 Boulons courts e 2 Contre crous 2 Ecrous collet d marrage lectrique uniquement 1 2 MONTAGE est n cessaire d effectuer quelques tapes de montage avant d utiliser le g n rateur Si des probl mes se pr sentent lors du montage du g n rateur merci d appeler la ligne d assistance pour les g n rateurs au 1 888 77LOWES 1 2 1 MONTAGE DU KIT D ACCESSOIRES Les roues sont dans l unit pour am liorer consid rablement la portabilit du g n rateur Vous aurez besoin des outils suivants pour correctement installer le kit Pinces bec effil Cliquet et une douille de 13 mm 0 5 po Cl polygonale de 13 mm 0 5 po REMARQUE Les roues ne sont pas concues pour une utilisation sur la route 1 S
88. expected demand for such parts Any Generac authorized and approved emission related replacement parts may be used in the performance of any ECS warranty maintenance or repairs and will be provided without charge to the purchaser owner Such use shall not reduce Generac ECS Warranty obligations Unapproved add on modified counterfeit and or grey market parts may not be used to modify or repair a Generac engine Such use voids this ECS Warranty and shall be sufficient grounds for disallowing an ECS Warranty claim Generac shall not be held liable hereunder for failures of any warranted parts of Generac equipment caused by the use of such an unapproved add on modified counterfeit and or grey market part EMISSION RELATED PARTS MAY INCLUDE THE FOLLOWING IF EQUIPPED FUEL METERING SYSTEM 4 AIRINJECTION SYSTEM A CARBURETOR AND INTERNAL PARTS A PULSE AIR VALVE B PRESSURE REGULATOR 5 EXHAUST SYSTEM AIR INDUCTION SYSTEM A CATALYST A INTAKE MANIFOLD B THERMAL REACTOR B AIR FILTER C EXHAUST MANIFOLD IGNITION SYSTEM A SPARK PLUGS B IGNITION COILS MODULE Part No 0H1911 Rev A 01 09 17 POWER SYSTEMS TWO YEAR LIMITED WARRANTY FOR GP SERIES PORTABLE GENERATORS For a period of two years from the date of original sale Generac Power Systems Inc Generac warrants its GP Series generators will be free from defects in materials and workmanship for the items and period set forth below Generac will at
89. hatter the battery and cause blindness or other serious injury A DANGER Do not permit smoking open flame sparks or any other source of heat around a battery Wear protective goggles rubber apron and rubber gloves when working around a battery Battery electrolyte fluid is an extremely corrosive sulfuric acid solution that can cause severe burns If spill occurs flush area with clear water immediately NOTE The battery shipped with the generator has been fully charged A battery may lose some of its charge when not in use for prolonged periods of time If the battery is unable to crank the engine plug in the 12V charger included in the accessory box see section Charging the Battery RUNNING THE GENERATOR DOES NOT CHARGE THE BATTERY Use battery charger plug to keep the battery charged and ready for use Battery charging should be done in a dry location 1 Plug charger into Battery Charger Input jack located on the control panel Plug wall receptacle end of the battery charger into a 120 Volt AC wall outlet Figure 11 2 Unplug battery charger from wall outlet and control panel jack when generator is going to be in use NOTE Do not use the battery charger for more than 48 hours at one charge Figure 11 Battery Charger Jack BATTERY CHARGER INPUT 10 3 1 MAINTENANCE SCHEDULE Follow the calendar intervals More frequent service is required when operating in adverse conditions noted below
90. hispas o cualquier otra fuente de calor alrededor de la bater a Use guantes protectores gafas y delantal de goma cuando trabaje alrededor de la bater a El fluido electrol tico de la bater a es una soluci n de cido sulf rico extremadamente corrosiva que puede causar severas quemaduras Si ocurre un derrame lave el rea con agua limpia inmediatamente NOTA La bater a inclu da en el generador ha sido cargada completamente Una bater a puede perder algo de su carga cuando no se le usa por tiempo prolongado Si la bater a es incapaz de arrancar el motor conecte el cargador de 12 voltios incluido en la caja de accesorios ver la secci n Cargando la bater a EL HACER FUNCIONAR EL GENERADOR NO CARGA LA BATER A Use el conector del cargador de bater a para mantener la bater a cargada y lista para usarse La carga de la bater a deber hacerse en una ubicaci n seca 1 Conecte el cargador en el conector de Entrada de cargador de bater a ubicado en el panel de control Conecte el extremo del recept culo de pared del cargador de la bater a en una toma de 120 VCA Figura 11 2 Desconecte el cargador de bater a de la toma de la pared y del conector del panel de control cuando el generador vaya a usarse NOTA No use el cargador dem bater as por m s de 48 hrs en carga Figura 11 Conector del cargador de bater a BATER A ENTRADA DEL CARGADOR 30 3 1 PROGRAMA DE MANTENIMIENTO Siga los interval
91. ilures caused by any external cause or act of God such as collision theft vandalism riot or wars nuclear holocaust fire freezing lightning earth quake windstorm hail volcanic eruption water or flood tornado or hurricane Damage related to rodent and or insect infestation Products that are modified or altered in a manner not authorized by Generac in writing e Any incidental consequential or indirect damages caused by defects in materials or workmanship or any delay in repair or replacement of the defective part s e Failure due to misapplication Telephone cellular phone facsimile internet access or other communication expenses Expenses related to customer instruction or troubleshooting where no manufacturing defect is found e Rental equipment used while warranty repairs are being performed Overnight freight or special shipping costs for replacement part s Overtime holiday or emergency labor e Starting batteries fuses light bulbs and engine fluids THIS WARRANTY IS IN PLACE OF ALL OTHER WARRANTIES EXPRESSED OR IMPLIED SPECIFICALLY GENERAC MAKES NO OTHER WARRANTIES AS TO THE MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE Any implied warranties allowed by law shall be limited in duration to the terms of the express warranty provided herein Some states do not allow limitations on how long an implied warranty lasts so the above limitation may not apply to you GENERAC S ONLY LIABILITY SHALL BE
92. ime in hours and tenths The hours will flash four times then alternate with the maintenance message four times until the meter resets itself 100 hours CHG OIL Oil Change Interval Every 100 hrs 2 3 CORD SETS AND CONNECTION PLUGS 2 3 1 120 VAC 20 DUPLEX RECEPTACLE This is a 120 Volt outlet protected against overload by a 20 Amp push to reset circuit breaker Figure 5 Use each socket to power 120 Volt AC single phase 60 Hz electrical loads requiring up to a combined 2400 watts 2 4 kW or 20 Amps of current Use only high quality well insulated 3 wire grounded cord sets rated for 125 Volts at 20 Amps or greater Keep extension cords as short as possible preferably less than 15 feet long to prevent voltage drop and possible overheating of wires Figure 5 120 Volt AC 20 Amp Duplex Receptacle O SS 2 3 2 120 240 VAC 30 AMP RECEPTACLE Use a NEMA L14 30 plug with this receptacle rotate to lock unlock Connect a suitable 4 wire grounded cord set to the plug and to the desired load The cord set should be rated for 250 Volts AC at 30 Amps or greater Figure 6 6 Figure 6 120 240 VAC 30 Amp Receptacle 120V 240V 30A Use this receptacle to operate 120 Volt AC 60 Hz single phase loads requiring up to 3600 watts 3 6 kW of power at 30 Amps or 240 Volt AC 60 Hz single phase l
93. inale du disjoncteur de la prise fournissant l alimentation Voir la 586 eee eG hath oa se Nan kon 1 200 section Ne pas surcharger le g n rateur Perceuse main 250 1 100 ale 450 2 5 NE PAS SURCHARGER LE G N RATEUR cedes Surcharger un g n rateur au dessus de sa capacit nominale de wattage Pompe jet O peut endommager le g n rateur et les dispositifs lectriques branch s Tondeuse gazon 1200 Respecter les consignes suivantes pour emp cher la surcharge de l unit AMPOUIR 100 Calculer le wattage total de tous les dispositifs lectriques brancher Four micro ondes 700 1 000 en m me temps Ce total ne doit PAS d passer la capacit de wattage Refroidisseur de lait 1 100 du g n rateur MEN Br leur mazout de chaudi re 300 Le wattage nominal des lumi res peut tre indiqu sur les ampoules Radiateur mazout 140 000 Btu 400 Le wattage nominal des outils des appareils et des moteurs se trouve Radiateur mazout 85 000 Btu 225 sur une tiquette ou un autocollant appos e sur le Radiateur mazout 30 000 Btu 150 Si l appareil l outil ou le moteur n indique pas le wattage multiplier la 0 UND MM p
94. ing This surge of power lasts only a few seconds when starting such motors Make sure to allow for high starting wattage when selecting electrical devices to connect to the generator 1 Figure the watts needed to start the largest motor 2 Add to that figure the running watts of all other connected loads The Wattage Reference Guide is provided to assist in determining how many items the generator can operate at one time NOTE All figures are approximate See data label on appliance for wattage requirements 2 6 WATTAGE REFERENCE GUIDE DEVICE A Running Watts Air Conditioner 12 000 Btu 1700 Air Conditioner 24 000 Btu 3800 Air Conditioner 40 000 Btu 6000 Battery Charger 20 500 Belt Sander irradia 1000 Chain SAW 22 28 1200 Circular Saw 6 1 2 800 to 1000 Clothes Dryer Electric 5750 Clothes Dryer Gas 700 Clothes Washer 422 444 is 24 1150 Coffee Maker Rene 1750 Compressor 1 BP haute se aise 2000 Compressor 3 4 HP 1800 Compressor 1 2 HP ii eve tesi 1400 GUNNO TON mene Ret RC ee ain 700 Dehurtidifler 2 cach day wena mene 650 Disc Sander 9 cocer b
95. ir pendant le stockage L exp rience montre galement que les carburants base d alcool appel s gazohol thanol ou m thanol peuvent absorber l humidit ce qui entra ne une s paration et la formation d acides pendant le stockage Un gaz acide peut endommager le circuit de carburant d un moteur pendant le stockage de celui ci Afin d viter tout probl me avec le moteur le circuit de carburant doit tre vid avant le stockage du moteur si celui ci est d au moins 30 jours Voir la section Stockage Ne jamais utiliser de produit nettoyant pour moteur ou carburateur dans le r servoir d essence tant donn que cela pourrait causer des dommages permanents Sch ma 8 R servoir d essence R servoir de carburant NE PAS remplir au dessus de la l vre Carburant 2 8 D MARRAGE DES MOTEURS D MARRAGE MANUEL A AVERTISSEMENT Ne jamais d marrer ou arr ter le moteur avec les dispositifs lectriques branch s dans les prises ET les dispositifs sous tension e D brancher toutes les charges lectriques des prises de l unit avant de d marrer le moteur S assurer que l unit est dans une position de niveau OUVRIR la soupape d arr t Sch ma 9 Mettre l interrupteur RUN STOP Marche Arr t du moteur sur la position ON Marche Faire glisser l trangleur du moteur de la position LEFT Gauche vers la position FULL CHOKE Etrangleur plein Sch ma 10 Pour d marrer le moteur
96. l lands EXHAUST LOCATION HAZARDS Never operate in an enclosed area or indoors NEVER use in the home or in partly enclosed areas such as garages even if doors and windows are open ONLY use outdoors and far from open windows doors vents and in an area that will not accumulate deadly exhaust DANGER Using a generator indoors CAN KILL YOU IN MINUTES Generator exhaust contains carbon monoxide This is a poison you cannot see or smell K NS Ele Only use OUTSIDE and far away from windows doors and vents NEVER use inside a home or garage EVEN IF doors and windows are open The engine exhaust fumes contain carbon monoxide which can you cannot see or smell This poisonous gas if breathed in sufficient concentrations can cause unconsciousness or even death Adequate unobstructed flow of cooling and ventilating air is critical to correct generator operation Do not alter the installation or permit even partial blockage of ventilation provisions as this can seriously affect safe operation of the generator The generator MUST be operated outdoors This exhaust system must be properly maintained Do nothing that might renderthe exhaust system unsafe or in noncompliance with any local codes and or standards Always use a battery operated carbon monoxide alarm indoors installed according to the manufacturers instructions If you start to feel sick dizzy or weak after the generator has been running move to fr
97. l oil drain plug and tighten securely Fill oil sump with recommended oil See Before Starting the Generator for oil recommendations Wipe up any spilled oil Dispose of used oil at a proper collection center 11 Maintenance 3 3 6 REPLACING THE SPARK PLUG See Engine Specifications for recommended spark plug Replace the plug once each year This will help the engine start easier and run better 1 Stop the engine and pull the spark plug wire off of the spark plug 2 Clean the area around the spark plug and remove it from the cylinder head Set the spark plug s gap to 0 70 0 80 mm 0 028 0 031 in Install the correctly gapped spark plug into the cylinder head Figure 12 Figure 12 Spark Plug Gap OG 3 3 7 BATTERY REPLACEMENT NOTE The battery shipped with the generator has been fully charged A battery may lose some of its charge when not in use for prolonged periods of time If the battery is unable to crank the engine plug in the 12V charger included in the accessory box see the Charging a Battery section RUNNING THE GENERATOR DOES NOT CHARGE THE BATTERY A CAUTION NEGATIVE battery terminal should 1 Always be DISCONNECTED FIRST 2 Always be CONNECTED LAST Figure 13 Battery Connections 12 3 4 SERVICE AIR CLEANER The engine will not run properly and may be damaged if using a dirty air cleaner Clean or replace the air cleaner paper filter once a year Clean or
98. lement remis par Generac Veuillez noter que la pr sente garantie ne s applique pas aux dommages accessoires importants ou indirects caus s par des d faillances mat rielles ou de fabrication ou par tout retard de r paration ou de remplacement de la ou des pi ce s d fectueuses La pr sente garantie remplace toutes les autres garanties implicites ou explicites En particulier Generac n met aucune garantie de conformit ou d usage pour un objectif particulier Certains tats ne permettent pas de poser une limite la dur e de la garantie implicite la limite susmentionn e ne s applique donc pas ces derniers La garantie du SCE ne s applique qu au syst me de contr le des missions de votre nouvel quipement En cas de conflit au niveau des termes de la pr sente garantie du SCE et de la garantie Generac la garantie de Generac pr vaudra Les garanties du SCE et de Generac d crivent les droits et obligations importantes relatives votre nouvel quipement Le service de garantie ne peut tre r alis que par une entreprise de service agr e par Generac En cas de demande du service de garantie des preuves mentionnant la date de vente l acqu reur au propri taire d origine doivent tre pr sent es Pour toute question concernant vos droits et responsabilit s de garantie merci de contacter Generac l adresse suivante ATTENTION WARRANTY DEPARTMENT GENERAC POWER SYSTEMS INC BOX 297 WHITEWATER WI 53190
99. n en extremo durante la operaci n Al jese del generador hasta que se haya enfriado para evitar quemaduras severas NO opere el generador en la lluvia No altere la construcci n del generador ni cambie los controles de modo que puedan crear una condici n de operaci n no segura e Nunca arranque detenga la unidad con cargas el ctricas conectadas a las tomas Y con dispositivos conectados y encendidos Arranque el motor y deje que se estabilice antes de conectar las cargas el ctricas Desconecte todas las cargas el ctricas antes de apagar el generador No inserte objetos a trav s de las ranuras de enfriamiento de la unidad e Al trabajar con este equipo mant ngase alerta en todo momento Nunca trabaje en el equipo cuando est f sica o mentalmente fatigado 21 Reglas de seguridad Nunca use el generador ni alguna de sus partes como escal n Pararse sobre la unidad puede tensar y romper partes y puede traer como resultado condiciones peligrosas de operaci n como escape de gases combustible o aceite En los modelos de arranque el ctrico desconecte el cable de bater a POSITIVO del arrancador del motor O el cable de bater a NEGATIVO del terminal de la bater a lo que sea m s f cil antes de transportar el generador NOTA Este generador est equipado con un silenciador de supresor de chispa El due o o el operador deben mantener el supresor de chispa en correcto estado de funcionamiento En el Es
100. nado el interruptor de Start Run Stop en la posici n Start El motor intentar arrancar Cuando el motor arranque suelte el interruptor a la posici n run funcionamiento Cuando el motor arranque mueva la palanca de Chole a 1 2 choke hasta que el motor funcione en forma suave y luego completamente a la posici n Run Si el motor decae mueva la palanca de Chole nuevamente a 1 2 choke hasta que el motor funcione en forma suave y luego a la posici n Run Este generador tambi n est equipado con un arrancador manual de recule que se puede usar si la bater a est descargada NOTA El interruptor debe estar en posici n RUN Para arrancar manualmente tome firmemente el manubrio del recule y tire lentemante hasta que se sienta que aumenta la resistencia Tire r pidamente arriba para arrancar el motor Luego siga la misma secuencia de choke NOTA Si el motor dispara pero no sigue funcionando mueva la palanca de choke a FULL CHOKE y repita las instrucciones de arranque IMPORTANTE No sobrecargue el generador Asimismo no sobrecargue los recept culos individuales Estas tomas est n protegidas contra sobrecargas con interruptores de circuito tipo presionar para reiniciar Si la corriente nominal de cualquiera de los interruptores se excede ese interruptor se abre y la salida el ctrica a ese recept culo se pierde Lea sobrecargue el generador con mucho cuidado 2 10 DETENER
101. nar energ a el ctrica para operar cargas el ctricas donde no haya servicio p blico de electricidad o en reemplazo de la red el ctrica en caso de apagones LEA ESTE MANUAL COMPLETAMENTE Si alguna parte de este manual no se entiende bien p ngase en contacto con el concesionario autorizado m s cercano para conocer los procedimientos de arranque operaci n y servicio El operador es responsable del uso apropiado y seguro de este equipo Recomendamos encarecidamente que el operador lea este manual y entienda completamente todas las instrucciones antes de usar este equipo Asimismo recomendamos con igual firmeza el instruir a otros usuarios para arrancar y operar apropiadamente la unidad Esto los prepara si necesitan operar el equipo en alguna emergencia El generador puede operar en forma segura eficiente y confiable s lo si se le ubica se le opera y mantiene en forma apropiada Antes de Operar o dar servicio al generador Familiaricese adhi rase estrictamente a todos los c digos y regulaciones locales estatales y nacionales e Estudie todas las advertencias de seguridad en este manual y en el producto con mucho cuidado Familiaricese con este manual y la unidad antes de usarla El fabricante no puede anticipar todas las posibles circunstancias que puedan involucrar peligros Las advertencias en este manual y en las etiquetas y calcoman as fijadas en la unidad son por tanto no completamente inclusivas Si se usa un
102. nk Fuel DO NOT Fill Above Lip 2 8 STARTING PULL START ENGINES WARNING Never start or stop engine with electrical devices plugged into the receptacles AND devices turned on Unplug all electrical loads from the units receptacles before starting the engine Make sure the unit is in a level position OPEN the Fuel Shut off Valve Figure 9 Turn engine RUN STOP switch to ON position Slide engine choke to the LEFT to FULL CHOKE position Figure 10 To start engine firmly grasp the recoil handle and pull slowly until increased resistance 5 felt Pull rapidly up and away When engine starts move choke knob to 1 2 CHOKE position until engine runs smoothly and then fully into RUN position If engine falters move choke back out to 1 2 CHOKE position until engine runs smoothly and then to RUN position engine fires but does not continue to run move choke lever to FULL CHOKE and repeat starting instructions Figure 9 Fuel Shut off Valve FUEL SHUTOFF Figure 10 Choke Position CHOKE LEVER LEFT CHOKE RIGHT RUN IMPORTANT Do not overload the generator Also do not overload individual panel receptacles These outlets are protected against overload with push to reset type circuit breakers If amperage rating of any circuit breaker is exceeded that breaker opens and electrical output to that receptacle is lost Read Don t O
103. nstale la tapa de drenaje de aceite y ci rrela con firmeza Llene el c rter de aceite con el aceite recomendado Vea Antes de arrancar el generador para mayores recomendaciones sobre el aceite Limpie el aceite que se haya derramado Disponga del aceite usado en un centro de recolecci n apropiado 31 3 3 6 REEMPLAZO DE LA BUJ A Ver la buj a recomendada en las especificaciones del motor Reemplace la buj a una vez al a o Esto ayudar a que el motor arranque con mayor facilidad y funcione mejor 1 Detenga el motor y tire del cable de buj as coloc ndolo lejos de las mismas 2 Limpie el rea alrededor de la buj a y ret rela de la cabeza del cilindro 3 Coloque el espaciamiento de la buj a en 0 70 0 80 mm 0 028 0 031 in Instale la buj a con el espaciamiento correcto en la cabeza del cilindro figura 12 Figura 12 Espaciamiento de la buj a 3 3 7 REEMPLAZO DE LA BATER A NOTA La bater a inclu da en el generador ha sido cargada completamente Una bater a puede perder algo de su carga cuando no se le usa por tiempo prolongado Si la bater a es incapaz de arrancar el motor conecte el cargador de 12 voltios incluido en la caja de accesorios ver la secci n Cargando una bater a EL HACER FUNCIONAR EL GENERADOR NO CARGA LA BATER A ACUIDADO El terminal NEGATIVO de la bater a deber 1 Estar siempre DESCONECTADO PRIMERO 2 Estar siempre CONECTADO AL FINAL Figura 13 Conexiones de
104. o de todas las otras Podadora de c sped s 500 cargas conectadas La gu a de referencia de potencias se proporciona para ayudarle a determinar cu ntos items puede operar el generador al mismo tiempo Calcule 3 veces la potencia de la lista para arrancar estos dispositivos 27 Operaci n 2 7 ANTES DE ARRANCAR EL GENERADOR Antes de operar el generador es necesario agregar aceite de motor y gasolina de esta manera 2 7 1 AGREGAR ACEITE DE MOTOR Todo aceite debe cumplir el est ndar m nimo de la American Petroleum Institute API Service Class SJ SL 0 superior No use aditivos especiales Seleccione el grado de viscosidad del aceite de acuerdo a la temperatura esperada de operaci n ver el gr fico tambi n Por encima de 40 F use SAE 30 Por debajo de 40 hasta 10 use 10W 30 e Por debajo de 10 F use 5W 30 sint tico Rango de temperatura del uso esperado ACUIDADO Cualquier intento de arrancar el motor antes de que se le haya dado servicio apropiado con el aceite recomendado puede traer como resultado una falla del motor Coloque el generador en una superficie nivelada Limpie el rea alrededor de la toma de aceite y retire la tapa Llene lentamente el aceite hasta que la varilla marque lleno Deje de llenar ocasionalmente para revisar el nivel de aceite Instale la varilla y aj stela seguramente Luego revise el nivel de aceite antes de arrancar
105. oads requiring up to 7200 watts 7 2 kW of power at 30 Amps The outlet is protected by two 30 Amp push to reset circuit breakers 2 4 HOW TO USE THE GENERATOR If there are any problems operating the generator please call the generator helpline at 1 888 436 3722 A DANGER Using a generator indoors CAN KILL YOU IN MINUTES Generator exhaust contains carbon monoxide This is a poison you cannot see or smell NEVER use inside home Only use OUTSIDE and or garage EVEN IF doors and windows are open far away from windows doors and vents 2 4 1 GROUNDING THE GENERATOR The National Electrical Code requires that the frame and external electrically conductive parts of this generator be properly connected to an approved earth ground Figure 7 Local electrical codes may also require proper grounding of the unit For that purpose connecting a No 10 AWG American Wire Gauge stranded copper wire to the grounding lug and to an earth driven copper or brass grounding rod electrode provides adequate protection against electrical shock However local codes may vary widely Consult with a local electrician for grounding requirements in the area Figure 7 Grounding the Generator Proper grounding of the generator will help prevent electrical shock in the event of a ground fault condition in the generator or in connected electrical devices Proper grounding also helps dissipate static electricity which often b
106. ocal los requerimientos de conexi n a tierra para su rea Use un circuito interruptor de falla de tierra en cualquier rea h meda o altamente conductiva como estanter as de metal o trabajos en acero No use cables el ctricos gastados pelados deshilachados o de alg n modo da ados con el generador Antes de realizar cualquier mantenimiento al generador desconecte los cables de arranque del motor si los hubiera para evitar un arranque accidental Desconecte primero el cable del borne de la bater a indicado como NEGATIVO NEG o Reconecte ese cable al final En caso de un accidente causado por descarga el ctrica apague inmediatamente la fuente de energ a el ctrica Si esto no es posible intente liberar a la v ctima del conductor vivo EVITE EL CONTACTO DIRECTO CON LA V CTIMA Une un implemento no conductivo como una soga o una tabla para liberar a la v ctima del conductor vivo Si la v ctima est inconsciente aplique los primeros auxilios y consiga ayuda m dica inmediatamente PELIGROS DE INCENDIO La gasolina es altamente INFLAMABLE y sus vapores son EXPLOSIVOS No permita que fumen haga fuegos abiertos chispas o calor en la vecindad mientras manipula gasolina Nunca a ada gasolina mientras la unidad est funcionando 0 est caliente Deje enfriar al motor completamente antes de a adir combustible Nunca llene el tanque de combustible en el interior de la casa Cumpla todas las leyes que regulan el almac
107. orsque l huile est totalement vidang e revisser le bouchon de vidange d huile et le resserrer solidement e Remplir le carter d huile avec l huile recommand e voir la section Avant le d marrage du g n rateur pour les recommandations sur l huile utiliser e Nettoyer toute trace d huile renvers e liminer l huile usag e dans un centre de collecte appropri 51 Maintenance 3 3 6 REMPLACEMENT DES BOUGIES D ALLUMAGE Voir Caract ristiques techniques du moteur pour la bougie d allumage recommand e Remplacer les bougies une fois par an Cela permettra un d marrage plus facile et un meilleur fonctionnement du moteur 1 Arr ter le moteur et d brancher le fil de bougie de la bougie d allumage 2 Nettoyer la zone autour de la bougie d allumage et la retirer de la culasse 3 R gler l cartement de bougie d allumage 0 70 0 80 mm 0 028 0 031 po Installer la bougie d allumage correctement cart e dans la culasse Sch ma 12 Sch ma 12 cartement de la bougie d allumage 3 9 7 REMPLACEMENT LA BATTERIE REMARQUE La batterie envoy e avec le g n rateur a t compl tement charg e Une batterie peut perdre une partie de sa charge lorsqu elle n est pas utilis e pendant des p riodes prolong es S il est impossible de d marrer le moteur l aide de la batterie brancher le chargeur de 12 V inclus dans la bo te d accessoires voir la section Chargement de la batterie FA
108. os del calendario Se requiere un servicio m s frecuente cuando se opera en condiciones adversas como las que se indica abajo Revise el nivel de aceite en cada uso Cambie el aceite Cada 100 horas o cambio de estaci n Revise la claridad de la v lvula Cada cambio de estaci n Servicio del filtro de aire Cada 200 horas o cambio de estaci n Reemplazo de buj as Cada cambio de estaci n Cambie el aceite luego de las primeras 30 horas de operaci n y luego en cada cambio de estaci n Cambie el aceite y el filtro de aceite cada mes si opera bajo condiciones pesadas de carga o altas temperaturas Limpie con m s frecuencia bajo condiciones de operaci n que involucren polvo y suciedad Reemplace las partes del filtro de aire si no se les puede limpiar adecuadamente Revise la claridad de la v lvula aj stela si es necesario luego de las primeras 50 horas de operaci n y cada 100 horas luego de ello 3 2 ESPECIFICACIONES DEL PRODUCTO 3 2 1 ESPECIFICACIONES DEL GENERADOR Capacidad 6 2 7 5 kW Potencia de lt 0 4 2000221 9 375 KW Voltaje AC nominal 120 240 Carga m xima nominal Corriente 240 31 25 Amps Corriente 120V anie tete 62 5 Amps Frecuencia 60 Hz 3600 RPM LL
109. ours whichever occurs first Limited comprehensive coverage on labor and parts listed All COMPONENTS NOTE For the purpose of this warranty consumer use means personal residential household or recreational use by original purchaser This warranty does not apply to units used for Prime Power in place of utility where utility power service is present or where utility power service does not normally exist Once a generator has experienced commercial or rental use it shall thereafter be considered a non consumer use generator for the purpose of this warranty All warranty expense allowances are subject to the conditions defined in the Generac Service Policy Manual THIS WARRANTY SHALL NOT APPLY TO THE FOLLOWING Generac built portable generators built prior to June 2010 Generac portable generators that utilize non Generac replacement parts Costs of normal maintenance and adjustments e Failures caused by any contaminated fuels oils or lack of proper oil levels Repairs or diagnostics performed by individuals other than Generac authorized dealers not authorized in writing by Generac Power Systems Failures due but not limited to normal wear and tear accident misuse abuse negligence or improper use As with all mechanical devices the Generac engines need periodic part s service and replacement to perform as designed This warranty will not cover repair when normal use has exhausted the life of a part s or engine Fa
110. park plug and pour about 1 2 ounce 15 ml of engine oil into the cylinder Cover spark plug hole with rag Pull the recoil starter a couple times to lubricate the piston rings and cylinder bore A CAUTION Avoid spray from spark plug hole when cranking engine e Install and tighten spark plug Do not connect spark plug wire Clean the generator s outer surfaces Check that cooling air slots and openings on generator are open and unobstructed e Store the unit in a clean dry place 3 6 OTHER STORAGE TIPS Do not store gasoline from one season to another Replace the gasoline can if it starts to rust Rust and or dirt in the gasoline will cause problems with the carburetor and fuel system If possible store the unit indoors and cover it to give protection from dust and dirt BE SURE TO EMPTY THE FUEL TANK If it is not practical to empty the fuel tank and the unit is to be stored for some time use a commercially available fuel stabilizer added to the gasoline to increase the life of the gasoline Cover the unit with a suitable protective cover that does not retain moisture DANGER NEVER cover the generator while engine and exhaust area are warm 13 Troubleshooting 4 1 TROUBLESHOOTING GUIDE PROBLEM Engine 1 running but no AC output is available Engine runs good but bogs down when loads are connected Engine will not start or starts and runs rough Engine shuts down during operation Engine
111. per level 10 Contact Authorized Service Facility 11 Contact Authorized Service Facility 12 Contact Authorized Service Facility AUO 1 Fill fuel tank 2 Fill crankcase to proper level 3 Contact Authorized Service Facility 1 Reduce load see Don t Overload the Generator 2 Clean or replace air filter 3 Contact Authorized Service Facility 1 Move choke to halfway position until engine runs smoothly 2 Contact Authorized Service Facility 15 Warranty FEDERAL EMISSION CONTROL WARRANTY STATEMENT YOUR WARRANTY RIGHTS AND OBLIGATIONS The United States Environmental Protection Agency EPA and Generac Power Systems Inc Generac are pleased to explain the Emission Control System warranty on your new 2008 and later equipment New equipment that use small spark ignited engines must be designed built and equipped to meet stringent anti smog standards for the federal government Generac will warrant the emission control system on your generator for the period of time listed below provided there has been no abuse neglect unapproved modification or improper maintenance of your equipment Your emission control system may include parts such as the carburetor ignition system fuel system catalytic converter and other associated emission related components if equipped MANUFACTURER S WARRANTY COVERAGE This emission control system is warranted for two years If during such warranty p
112. placing the Spark Plug 12 3 3 7 Battery 12 3 4 Service Air Cleaner 12 3 5 Long Term Storage 12 3 6 Other Storage 2 13 Troubleshooting 14 4 1 Troubleshooting Guide 14 Dii Mere NES 15 es 16 Introduction INTRODUCTION Thank you for purchasing this model by Generac Power Systems Inc This model is compact high performance air cooled engine driven generator designed to supply electrical power to operate electrical loads where no utility power is available or in place of utility due to a power outage READ THIS MANUAL THOROUGHLY If any portion of this manual is not understood contact the nearest Authorized Dealer for starting operating and servicing procedures The operator is responsible for proper and safe use of the equipment We strongly recommend that the operator read this manual and thoroughly understand all instructions before using the equipment We also strongly recommend instructing other users to properly start and operate the unit This prepares them if they need to operate the equipment in an emergency The generator can operate safely efficiently and reliably only if it is properly located operated and maintained Before operating or servicing the generator Become familiar with and strictly adhere to all local state and n
113. ppement Carburateur Pot d chappement La p riode de conformit des missions laquelle il est fait r f rence sur l tiquette de conformit des missions indique le nombre d heures de fonctionnement pendant lesquelles le moteur a prouv respecter les exigences EPA en mati re d mission 3 3 RECOMMANDATIONS G N RALES La garantie du g n rateur ne couvre pas les l ments qui ont t soumis un abus ou une n gligence de l op rateur Afin de recevoir le montant total de la garantie l op rateur doit entretenir le g n rateur de la fa on indiqu e dans ce manuel Certains r glages doivent tre effectu s r guli rement pour entretenir correctement le g n rateur Tous les r glages de la section Maintenance de ce manuel doivent tre effectu s au moins une fois par saison Respecter les exigences dans le tableau de Programme de maintenance REMARQUE Une fois par an remplacer la bougie d allumage et le filtre air Une nouvelle bougie d allumage et un filtre air propre garantissent un bon m lange carbur et aide le moteur mieux fonctionner et durer plus longtemps 3 3 1 MAINTENANCE DU G N RATEUR La maintenance du g n rateur consiste garder l unit propre et s che Faire fonctionner et stocker l unit dans un environnement sec et propre o il ne sera pas expos trop de poussi res de salet s d humidit ou de vapeurs corrosives Les fentes de refroidissement du g n r
114. qu par Generac Power Systems Inc Ce mod le est un g n rateur entra n par moteur compact haute performance refroidi l ai con u pour fournir l alimentation lectrique afin de faire fonctionner les charges lectriques lorsqu aucun r seau lectrique n est disponible ou la place du r seau en raison d une coupure de courant LIRE ATTENTIVEMENT CE MANUEL En cas d incompr hension d une partie de ce manuel contacter le d positaire agr le plus proche pour conna tre les proc dures de d marrage de fonctionnement et d entretien L op rateur est responsable de l utilisation correcte et s re de l quipement Nous recommandons fortement l op rateur de lire ce manuel et de comprendre compl tement toutes les instructions avant d utiliser l quipement Nous recommandons galement fortement d apprendre d autres utilisateurs comment correctement d marrer et faire fonctionner l unit Cela les pr pare au cas o ils auraient besoin de faire fonctionner l quipement pour une urgence Le g n rateur peut fonctionner en toute s curit de fa on efficace et de fa on fiable uniquement s il est correctement install utilis et entretenu Avant de faire fonctionner ou d effectuer l entretien du g n rateur e Se familiariser avec et respecter strictement tous les codes et r glementations locaux d Etat et nationaux Lire attentivement tous les avertissements de s curit figurant dans ce manuel et s
115. que le carburateur le tuyau pour combustible ou le r servoir L exp rience montre galement que les carburants base d alcool appel s gazohol thanol ou m thanol peuvent absorber l humidit ce qui entraine une s paration et la formation d acides pendant le stockage Un gaz acide peut endommager le circuit de carburant d un moteur pendant le stockage de celui ci Afin d viter tout probl me avec le moteur le circuit de carburant doit tre vid avant le stockage du moteur si celui ci est d au moins 30 jours Pour cela e Vidanger le r servoir d essence de tout le carburant qu il contient ADANGER Vider l essence dans des conteneurs adapt s situ s l ext rieur loin de toute flamme nue S assurer que le moteur est froid Ne pas fumer Maintenance D marrer et faire fonctionner le moteur jusqu ce qu il s arr te suite une panne d essence aisser le moteur refroidir puis vider l huile du carter Remplir jusqu au niveau recommand e Retirer la bougie d allumage et verser environ 0 5 onces 15 ml d huile pour moteur dans le cylindre Couvrir l orifice de la bougie d allumage avec un chiffon Tirer plusieurs fois le lanceur rappel pour lubrifier les segments de piston et l al sage du cylindre ATTENTION viter d asperger partir des trous de la bougie d allumage lorsque le moteur tourne e Remettre et serrer la bougie d allumage Ne pas brancher le fil de bougie Nettoyer les surf
116. raer la humedad lo que llega a la separaci n y formaci n de cidos durante el almacenamiento Los gases cidos pueden da ar el sistema de combustible de un motor durante el almacenamiento Para evitar problemas con el motor el sistema de combustible deber vaciarse antes de almacenarse por 30 d as o m s Ver la secci n de Almacenamiento Nunca use productos limpiadores de motor o carburador en el tanque de combustible ya que puede ocasionar da o permanente Figura 8 Tanque de combustible Tanque de combustible NO LLENAR m s all Combustible de esta separaci n 2 8 ARRANQUE DE MOTORES DE RECULE AADVERTENCIA Nunca arranque ni detenga el motor con los dispositivos el ctricos conectados a los receptaculos ni encendidos Desconecte todas las cargas el ctricas de los receptaculos de la unidad antes de arrancar el motor Aseg rese de que la unidad est en una posici n nivelada ABRA la v lvula de cierre de combustible Figura 9 Gire el interruptor RUN STOP a la posici n ON Deslice la palanca de CHOKE del motor a la posici n IZQUIERDA de FULL CHOKE completo Figura 10 Para arrancar el motor tome firmemente el manubrio del recule y tire lentemante hasta que se sienta que aumenta la resistencia Tire r pidamente hacia afuera Cuando el motor arranque mueva la palanca de Choke a 1 2 CHOKE hasta que el motor funcione en forma suave y luego completamente a la posici n RUN Si el mo
117. ree the victim from the live conductor AVOID DIRECT CONTACT WITH THE VICTIM Use a non conducting implement such as a rope or board to free the victim from the live conductor If the victim is unconscious apply first aid and get immediate medical help FIRE HAZARDS Gasoline is highly FLAMMABLE and its vapors are EXPLOSIVE Do not permit smoking open flames sparks or heat in the vicinity while handling gasoline Never add fuel while unit is running or hot Allow engine to cool completely before adding fuel Never fill fuel tank indoors Comply with all laws regulating storage and handling of gasoline Do not overfill the fuel tank Always allow room for fuel expansion If tank is over filled fuel can overflow onto a hot engine and cause FIRE or an EXPLOSION Never store generator with fuel in tank where gasoline vapors might reach an open flame spark or pilot light as on a furnace water heater or clothes dryer FIRE or EXPLOSION may result Allow unit to cool entirely before storage Wipe up any fuel or oil spills immediately Ensure that no combustible materials are left on or near the generator Keep the area surrounding the generator clean and free from debris and keep a clearance of five 5 feet on all side to allow for proper ventilation of the generator Safety Rules Do not insert objects through unit s cooling slots Do not operate the generator if connected electrical devices MODEL NO overheat if electrical output i
118. reemplace el filtro de aire 3 Contacte a un servicio autorizado 1 Mueva el choke a la posici n media hasta que el motor funcione suavemente 2 Contacte a un servicio autorizado 35 SUS DERECHOS Y OBLIGACIONES DE GARANT A La Agencia de protecci n ambiental de los Estados Unidos EPA y Generac Power Systems Inc Generac se complacen en explicar la garant a del sistema de control de emisiones para su nuevo equipo del a o 2008 o posterior Equipo nuevo que use motores peque os de chispa deben estar dise ados construidos y equipados para cumplir est ndares anti smog muy exigentes para el gobierno federal Generac garantizar los sistemas de emisi n en su motor por el periodo de tiempo listado abajo siempre que no haya abuso negligencia modificaci n o mantenimiento inapropiado de su equipo Su sistema de control de emisi n puede incluir partes como carburador sistema de ignici n sistema de combustible convertidor catal tico y otros componentes asociados relacionados a la emisi n si los tuviera COBERTURA DE LA GARANT A DEL FABRICANTE Este sistema de control de emisi n est garantizado por dos a os Si durante este periodo de garant a se encuentra que cualquier parte relacionada a las emisiones est defectuosa en materiales o mano de obra se efectuar las reparaciones o el intercambio por parte de un concesionario de servicio autorizado de Generac RESPONSABILIDADES DE GARANT A DEL PROPIETARIO Como propiet
119. replace more often if operating under dusty conditions Figure 14 To clean or replace paper air filter Remove air cleaner cover and remove paper filter Clean paper filter by tapping it gently on a solid surface If the filter is too dirty replace it with a new one Dispose of the old filter properly Clean air cleaner cover then insert new paper filter into the base of the air cleaner Re install air cleaner cover Figure 14 Air Filter CL NOTE To order a new air filter please contact the nearest authorized service center at 1 800 333 1322 3 5 LONG TERM STORAGE It is important to prevent gum deposits from forming in essential fuel system parts such as the carburetor fuel hose or tank during storage Also experience indicates that alcohol blended fuels called gasohol ethanol or methanol can attract moisture which leads to separation and formation of acids during storage Acidic gas can damage the fuel system of an engine while in storage To avoid engine problems the fuel system should be emptied before storage of 30 days or longer as follows Remove all gasoline from the fuel tank DANGER Drain fuel into approved container outdoors away from open flame Be sure engine is cool Do not smoke Maintenance Start and run engine until engine stops from lack of fuel Allow the engine to cool then drain oil from crankcase Refill with recommended grade Remove s
120. res pour effectuer l entretien Lorsque l horom tre est en mode Flash Alert Alerte clignotante le message de maintenance s affichera toujours en alternance avec le temps coul en heures et en dixi mes Les heures feront clignoter quatre heures puis s afficheront en alternance avec le message de maintenance quatre fois jusqu ce que la r initialisation de l horom tre 100 heures CHG OIL Intervalle de changement d huile Toutes les 100 heures 2 3 CORDONS ET CONNECTEURS 2 3 1 PRISE DOUBLE 120 V C A 20 A ll s agit d une prise de 120 volts prot g e contre la surcharge par disjoncteur de type pousser pour r enclencher de 20 Sch ma 5 Utiliser chaque prise pour alimenter les charges lectriques monophas es de 120 V c a 60 Hz n cessitant 2 400 watts 2 4 kW ou 20 A de courant Utiliser uniquement des cordons trois fils avec mise la terre bien isol s de haute qualit con us pour 125 Volts 20 A ou plus Garder les cordons prolongateurs aussi courts que possible de pr f rence une longueur inf rieure 15 pieds afin d emp cher une chute de tension et une surchauffe potentielle des c bles Sch ma 5 Prise double 120 V c a 20 A O 2 3 2 PRISE 120 240 V C A 30 A Utiliser une fiche NEMA L14 30 avec cette prise tourner pour verrouiller d verrouiller Brancher
121. ridad no pueden eliminar los peligros que indican El sentido com n y un estricto cumplimiento de las instrucciones especiales cuando se realiza la acci n o servicio son esenciales para evitar accidentes Cuatro s mbolos de seguridad usados com nmente acompa an los bloques de PELIGRO ADVERTENCIA y CUIDADO El tipo de informaci n que cada uno indica es como sigue Este s mbolo se ala importante informaci n de seguridad que si no se sigue puede poner en peligro la seguridad personal y o las propiedades de otros A Este s mbolo indica un peligro potencial de explosi n Este simbolo indica un peligro potencial de incendio Este simbolo indica un peligro potencial de choque el ctrico PELIGROS GENERALES e Nunca opere en reas cerradas o interiores Por razones de seguridad el fabricante recomienda que el mantenimiento de este equipo sea llevado a cabo por un concesionario autorizado Inspeccione el generador con regularidad y p ngase en contacto con el concesionario autorizado m s cercano si necesita repararlo o conseguir repuestos Opere el generador s lo en superficies planas y donde est expuesto a excesiva humedad suciedad polvo 0 vapores corrosivos Mantenga las manos pies ropa etc lejos de las correas de tracci n ventiladores y otras partes m viles Nunca retire ninguna protecci n o escudo de ventilador mientras la unida est operando Ciertas partes del generador se calienta
122. rr ter le moteur avec les dispositifs lectriques branch s dans les prises ET les dispositifs sous tension e D brancher toutes les charges lectriques des prises de l unit avant de d marrer le moteur e S assurer que l unit est dans une position de niveau Ouvrir la soupape d arr t Sch ma 9 Mettre le bouton CHOKE trangleur du moteur l ext rieur sur la position Full Choke Etrangleur plein Sch ma 10 Pour d marrer le moteur appuyer et maintenir enfonc l interrupteur Start Run Stop D marrage Marche Arr t sur la position Start D marrage Le moteur tournera et commencera d marrer Lorsque le moteur d marre rel cher l interrupteur sur la position Run Marche Lorsque le moteur d marre mettre le bouton Choke trangleur sur la position 1 2 Choke Etrangleur moiti jusqu ce que le moteur fonctionne doucement et ensuite sur la position Run Marche Si le moteur vibre remettre le bouton Choke Etrangleur sur la position 1 2 Choke Etrangleur moiti jusqu ce que le moteur fonctionne doucement et ensuite sur la position Run Marche e g n rateur est galement quip d un lanceur rappel manuel qui peut tre utilis en cas de d chargement de la batterie REMARQUE L interrupteur doit tre en position RUN Marche Pour d marrer manuellement attraper fermement la poign e de rappel et tirer jusqu ce qu une r sistance
123. s cidos pueden da ar el sistema de combustible de un motor durante el almacenamiento Para evitar problemas con el motor el sistema de combustible deber vaciarse antes de almacenarse por 30 d as o m s como sigue e Retire toda la gasolina del tanque de combustible PELIGRO Aprene el combustible en contenedores apropiados en exteriores lejos de las flamas abiertas Aseg rese de que el motor est fr o No fume Arranque y haga funcionar el motor hasta que se detenga falta de combustible Deje enfriar el motor luego drene el aceite del c rter Rellene con el grado recomendado Retire la buj a y llene alrededor de 1 2 onza 15 ml de aceite de motor en el cilindro Cubra el agujero de la buj a con un trapo Tire del arrancador de recule un par de veces para lubricar los anillos del pist n y el recorrido del cilindro ACUIDADO Evite la pulverizaci n del agujero de la buj a en el arranque Instale y ajuste la buj a No conecte el cable de buj a Limpie las otras superficies del generador Revise que las aberturas y ranuras de aire de ventilaci n en el generador est n abiertas y sin obstrucciones Almacene la unidad en un lugar limpio y seco 3 6 OTROS CONSEJOS PARA ALMACENAMIENTO No almacene gasolina de una estaci n a otra Reemplace la gasolina si empieza a oxidarse El xido 0 suciedad en la gasolina causar problemas con el carburador y el sistema de combustible Si fuera posibl
124. s del generador Estas aperturas deben mantenerse limpias y sin obstrucciones 9 3 3 MANTENIMIENTO DEL MOTOR PELIGRO Cuando trabaja el generador siempre se debe desconectar el cable negativo de la bateria Tambi n desconecte el cable de la bujia y mant ngalo lejos de esta 3 3 4 REVISAR EL NIVEL DE ACEITE Vea la secci n ANTES DE ARRANCAR EL GENERADOR para mayor informaci n sobre la revisi n del nivel de aceite El nivel de aceite debe revisarse antes de cada uso o al menos cada ocho horas de operaci n Siempre mantenga el nivel de aceite 3 3 5 CAMBIO DE ACEITE Cambie el aceite luego de las primeras 30 horas de operaci n Cambie el aceite cada 100 horas o cada cambio de estaci n luego de ello Si est haciendo funcionar la unidad en condiciones de polvo o suciedad o en clima extremadamente c lido cambie el aceite con m s frecuencia ACUIDADO El aceite caliente puede causar quemaduras Permita que el motor enfr e antes de drenar el aceite Evite una exposici n prolongada o repetida de la piel con el aceite usado Lave completamente las reas expuestas con jab n Use las siguientes instrucciones para cambiar el aceite luego que el motor enfrie Limpie el rea alrededor de la manguera de drenaje del aceite Retire la tapa de drenaje de aceite del motor y la tapa de llenado de aceite para que drene completamente en un contenedor adecuado Cuando el aceite haya drenado completamente i
125. s lost if engine or generator sparks or if flames or smoke are observed while unit is running Keep a fire extinguisher near the generator at all times STANDARDS INDEX In the absence of pertinent standards codes regulations and laws the published information listed below may be used as a guideline for operation of this equipment Always reference the latest revision available for the standards listed 1 NFPA No 70 NFPA HANDBOOK OF NATIONAL ELECTRIC CODE 2 Article X NATIONAL BUILDING CODE available from the American Insurance Association 85 John Street New York N Y 10038 3 AGRICULTURAL WIRING HANDBOOK available from the Food and Energy Council 909 University Avenue Columbia MO 65201 4 3634 INSTALLATION AND MAINTENANCE OF FARM STANDBY ELECTRICAL SYSTEMS available from the American Society of Agricultural Engineers 2950 Niles Road St Joseph MI 49085 CALIFORNIA PROPOSITION 65 WARNING Engine exhaust and some of its constituents are known to the State of California to cause cancer birth defects and other reproductive harm CALIFORNIA PROPOSITION 65 WARNING This product contains or emits chemicals known to the State of California to cause cancer birth defects and other reproductive harm General Information 1 1 UNPACKING e Remove all packaging material e Remove separate accessory box Remove the generator from carton 1 1 1 AC
126. s prolong es S il est impossible de d marrer le moteur l aide de la batterie brancher le chargeur de 12 V inclus dans la bo te d accessoires voir la section Chargement de la batterie FAIRE FONCTIONNER LE GENERATEUR NE CHARGE PAS LA BATTERIE Utiliser la prise du chargeur de batterie afin de garder la batterie charg e et pr te l emploi Le chargement de la batterie doit tre effectu dans un endroit sec 1 Brancher le chargeur dans la prise jack Entr e du chargeur de batterie situ e sur le panneau de commande Brancher l extr mit de la prise de courant murale du chargeur de batterie dans une prise murale c a de 120 volts Sch ma 11 2 D brancher le chargeur de batterie de la prise murale et de la prise jack du panneau de commande lorsque le g n rateur va tre utilis REMARQUE Ne pas utiliser le chargeur de batterie pendant plus de 48 heures cons cutives Sch ma 11 Prise jack du chargeur de la batterie BATTERIE Entr e du chargeur 50 3 1 PROGRAMME DE MAINTENANCE Suivre les intervalles du calendrier Un entretien plus fr quent est n cessaire lors du fonctionnement dans les conditions d favorables indiqu es ci dessous V rifier le niveau d huile Lors de chaque utilisation Changer l huile Toutes les 100 heures ou chaque saison V rifier le jeu des soupapes chaque saison Entretien du filtre air Toutes les 200 heures ou chaque saison Remplacer la bougie
127. s provided to you by Generac pursuant to federal law See also the Generac Limited Warranties for Generac Power Systems Inc which is enclosed herewith on a separate sheet also provided to you by Generac Note that this warranty shall not apply to any incidental consequential or indirect damages caused by defects in materials or workmanship or any delay in repair or replacement of the defective part s This warranty is in place of all other warranties expressed or implied Specifically Generac makes no other warranties as to the merchantability or fitness for a particular purpose Some states do not allow limitations on how long an implied warranty lasts so the above limitation may not apply to you The ECS Warranty applies only to the emission control system of your new equipment If there is any conflict in terms between the ECS Warranty and the Generac Warranty the Generac Warranty shall apply Both the ECS Warranty and the Generac Warranty describe important rights and obligations with respect to your new engine Warranty service can be performed only by a Generac Authorized Warranty Service Facility When requesting warranty service evidence must be presented showing the date of the sale to the original purchaser owner If you have any questions regarding your warranty rights and responsibilities you should contact Generac at the following address ATTENTION WARRANTY DEPARTMENT GENERAC POWER SYSTEMS INC P O BOX 297 WHITEWATER WI
128. s utiliser le g n rateur ou n importe laquelle de ses pi ces comme marche Monter sur l unit peut craser et casser les pi ces et peut entra ner des conditions de fonctionnement dangereuses suite une fuite de gaz d chappement une fuite de carburant une fuite d huile etc 41 R gles de s curit e Sur les mod les d marrage lectrique d brancher le c ble de batterie POSITIF du d marreur du moteur OU le c ble de batterie NEGATIF de la borne de la batterie ce qui est le plus facile avant de transporter le g n rateur REMARQUE Ce g n rateur est quip d un silencieux pare tincelles Le propri taire l op rateur du g n rateur devra garder le pare tincelles en bon tat Dans l Etat de Californie un pare tincelles est exig par la loi Section 4442 du California Public Resources Code Code de ressources publiques de Californie Les autres Etats peuvent avoir des lois similaires Les lois f d rales s appliquent sur les terres f d rales DANGERS D CHAPPEMENT ET D EMPLACEMENT Ne jamais faire fonctionner dans un espace clos ou l int rieur NE JAMAIS utiliser l int rieur ou dans des espaces partiellement clos tels que les garages m me si les portes et les fen tres sont ouvertes Utiliser UNIQUEMENT l ext rieur et loin des fen tres portes ouvertes ventilations et dans un espace dans lequel le gaz d chappement ne s accumulera pas de fa on mortelle DANG
129. se fasse sentir Remonter rapidement et d marrer le moteur Puis suivre la m me s quence de l trangleur REMARQUE Si le moteur chauffe mais ne continue pas fonctionner mettre le levier de l trangleur sur FULL CHOKE Etrangleur plein et r p ter les instructions de d marrage IMPORTANT Ne pas surcharger le g n rateur Aussi ne pas surcharger les prises individuelles du panneau Ces prises sont prot g es contre la surcharge avec des disjoncteurs de type pousser pour r enclencher Si la valeur nominale d amp rage d un disjoncteur est d pass e ce disjoncteur s ouvre et la puissance lectrique de cette prise est perdue Lire attentivement la section Ne pas surcharger le g n rateur 2 10 ARR T DU MOTEUR Arr ter toutes les charges puis d brancher les charges lectriques des prises du panneau du g n rateur Ne jamais d marrer ou arr ter le moteur avec les dispositifs lectriques branch s et sous tension Laisser le moteur fonctionner circuit ouvert pendant plusieurs minutes pour stabiliser les temp ratures internes du moteur et du g n rateur e Mettre l interrupteur Run Stop Marche Arr t sur la position OFF Arr t e Fermer la vanne de combustible 2 11 SYSTEME D ARR T DE BAS NIVEAU D HUILE Le moteur est quip d un d tecteur de bas niveau d huile qui arr te le moteur automatiquement lorsque le niveau d huile chute en dessous d un niveau sp cifique Si le moteur s arr
130. sentir faible apr s le fonctionnement du g n rateur respirez de l air frais IMMEDIATEMENT Consultez un m decin car vous pourriez avoir t empoisonn au monoxyde de carbone 42 DANGERS LECTRIQUES Le g n rateur produit une tension dangereusement haute pendant sonfonctionnement Eviter le contact avec les fils nus les bornes les branchements etc pendant le fonctionnement de l unit m me sur l quipement branch au g n rateur S assurer que tous les couvercles les dispositifs de protection et les barri res sont en place avant de faire fonctionner le g n rateur Ne jamais manipuler tout type de cordon ou de dispositif lectrique qui est dans l eau alors que vous tes pieds nus ou que vos mains ou vos pieds sont mouill s CELA ENTRAINERA UN RISQUE D ELECTROCUTION Le National Electric Code Code lectrique national exige que le b ti et que les pi ces externes lectriquement conductrices du g n rateur soient correctement reli s une terre approuv e Les codes lectriques locaux peuvent galement exiger la bonne mise la terre du g n rateur Consulter un lectricien local pour connaitre les exigences de mise la terre dans la r gion Utiliser un disjoncteur de fuite la terre dans toute zone humide ou tr s conductrice telle que le carter protecteur m tallique ou l aci rie Ne pas utiliser de cordons lectriques us s nus effiloch s ou autrement endommag s avec le g n rateur Avant
131. t 2 Cordon mal branch ou d fectueux 3 Dispositif branch d fectueux 4 Erreur au niveau du g n rateur 1 Court circuit dans l une des charges branch es 2 Surcharge du g n rateur 3 Vitesse du moteur trop faible 4 Court circuit du g n rateur La soupape d arr t est sur OFF Arr t Filtre air sale Panne d essence Essence vici e 5 Fil de bougie d branch de la bougie d allumage Bougie d allumage d fectueuse Pr sence d eau dans l essence Sur tranglement des gaz Niveau d huile faible 10 M lange d essence trop riche 11 Soupape d admission bloqu e en position ouverte ou ferm e 12 Perte de compression du moteur 1 Panne d essence 2 Niveau d huile faible 3 Erreur au niveau du moteur 1 Charge trop lev e 2 Filtre air sale 3 R paration n cessaire du moteur 1 Etrangleur ouvert trop t t 2 M lange trop riche ou trop pauvre dans le carburateur SOLUTION 1 R armer le disjoncteur 2 V rifier et r parer 3 Brancher un autre dispositif en bon tat 4 Contacter un centre d entretien agr D brancher la charge lectrique court circuit e Voir la section Ne pas surcharger le g n rateur Contacter un centre d entretien agr Contacter un centre d entretien agr Mettre la soupape d arr t sur ON Marche Nettoyer ou remplacer le filtre air Remplir le r servoir d essence Vidang
132. t les dispositions de la sous section 4 ci dessus les services ou r parations sous garantie doivent tre effectu s aux centres d entretien agr s Generac Si le moteur est inspect par un service de garantie agr par Generac les frais de diagnostic ne seront pas la charge de l acqu reur du propri taire si la r paration entre dans le cadre de la garantie Generac est tenu pendant la dur e de la Garantie du SCE de conserver un stock de pi ces relatives aux missions et garanties suffisant afin de r pondre la demande desdites pi ces 8 Toute pi ce de rechange relative aux missions agr e et approuv e par Generac pourra tre utilis e pour la r alisation de toute maintenance ou r paration effectu e dans le cadre de la garantie du SCE et sera fournie sans frais la charge de l acqu reur du propri taire Cette utilisation ne r duira pas les obligations de Generac dans le cadre de la Garantie du SCE 9 Toute pi ce non approuv e ajout e modifi e contrefaite et provenant de l conomie souterraine ne pourra pas tre utilis e afin de modifier ou de r parer un moteur Generac L utilisation de telles pi ces annule la Garantie du SCE et constituera un motif suffisant pour rejeter toute demande de b n fice de la Garantie du SCE Generac ne sera pas responsable des d faillances des pi ces garanties d un quipement Generac dues l utilisation de pi ces non approuv es ajout es modifi es contrefaites
133. tacto con Generac en la siguiente direcci n ATENCI N DEPARTAMENTO DE GARANT AS GENERAC POWER SYSTEMS INC BOX 297 WHITEWATER WI 53190 Parte No 0H1911 Rev 01 09 36 GARANTIA DEL SISTEMA CONTROL EMISIONES Garant a de sistema de control de emisiones garant a ECS para equipo que usa motores peque os de chispa a Aplicabilidad Esta garant a se aplica a equipo que utiliza motores peque os para fuera de pista El periodo de garant a ECS empezar en la fecha en que el equipo nuevo es comprado por o entregado a su propietario comprador final original y continuar por los siguientes 24 meses consecutivos b Cobertura general de la garant a de emisiones Generac garantiza al propietario comprador final original del motor o equipamiento nuevo y a cada subsiguiente comprador propietario que el ECS cuando se instal estuvo 1 Dise ado construido y equipado para cumplir con todas las regulaciones aplicables y 2 Libre de defectos en materiales y mano de obra que cause la falla de una parte garantizada en cualquier momento durante el periodo de garant a ECS c La garant a sobre partes relacionadas a la emisi n se interpretar n como sigue 1 Cualquier parte garantizada que no est programada para reemplazo como mantenimiento requerido en el Manual del propietario ser garantizada en el periodo de garant a ECS Si fallara cualquier parte durante el periodo de garant a ECS deber ser repar
134. tado de California se requiere por ley un supresor de chispa Secci n 4442 del C digo de Recursos P blicos de California Otros estados pueden tener leyes similares Las leyes federales se aplican en terrenos federales PELIGROS DEL ESCAPE Y UBICACI N Nunca opere en reas cerradas o interiores NUNCA lo use en el hogar o en reas parcialmente cerradas como garajes a n si las puertas y ventanas est n abiertas Uselo SOLO en exteriores y lejos de ventanas abiertas puertas ductos de ventilaci n y en reas que no acumular n el mortal gas del escape PELIGRO El uso de un generador en interiores PUEDE MATARLE EN MINUTOS El escape del generador contiene mon xido de carbono Este es un veneno invisible y sin olor selo s lo EN EXTERIORES y lejos de ventanas puertas y ductos de ventilaci n NUNCA lo use dentro de una casa o garaje AUN SI las puertas y las ventanas est n abiertas Los humos del escape del motor contienen mon xido de carbono que se puede oler ni ver Este gas venenoso si se aspira en concentraciones suficientes puede hacerle perder la conciencia y causarle la muerte El flujo adecuado y sin obstrucciones de aire para ventilaci n y refrigeraci n es cr tico para la correcta operaci n del generador No altere la instalaci n ni permita que haya siquiera un bloqueo parcial de la provisi n de ventilaci n ya que esto puede afectar seriamente la operaci n segura del gener
135. the Frame Foot then install the Locking Flange Nuts Slide the Hex Head Bolts through the holes in the Frame Rail Slide the Frame Foot onto the Hex Head Bolts then install the Locking Flange Nuts 3 Refer to Figure 1 and install the Handle as shown Slide the long Bolts through the Handle Bracket and Handle then install the Hex Nuts Figure 1 Wheel amp Handle Assembly M8 BOLT bs SHORT 8 ACORN NUT HANDLE ASSEMBLY IA 1 AXLE PIN 2X WHEEL h X 1 2 FLAT FRAME WASHER FOOT X COTTER 2X RUBBER FOUT PIN X M8 NUT 1 2 2 BATTERY CABLE CONNECTION ELECTRIC START ONLY The unit has been deliberately shipped with the battery cables disconnected To connect the battery see Figure 13 for connection details 1 Cut off cable ties securing battery cables and remove red covers from battery terminals 2 First connect the red cable to the positive battery terminal with the bolt lock washer and nut supplied 3 Connect the black cable to the negative battery terminal with the bolt lock washer and nut supplied 4 Make sure all connections are secure Slide the rubber boots over the terminals and connection hardware NOTE If the battery is unable to start the engine charge it with the 12V charger included in the accessory box see the Charging a Battery section for details 2 1 KNOW THE GENERATOR Read the Owner s Manual and Safety Rules before operating this generator
136. tor arranca mueva la palanca de Choke a 1 2 CHOKE hasta que el motor funcione en forma suave y luego a la posici n RUN Si el motor dispara pero no sigue funcionando mueva la palanca de choke a FULL CHOKE y repita las instrucciones de arranque Figura 9 V lvula de cierre de combustible CIERRE DE COMBUSTIBLE Figura 10 Posici n de Choke PALANCA DE CHOKE IZQUIERDA CHOKE DERECHA FUNCIONAR IMPORTANTE No sobrecargue el generador Asimismo no sobrecargue los recept culos individuales Estas tomas est n protegidas contra sobrecargas con interruptores de circuito tipo presionar para reiniciar Si la corriente nominal de cualquiera de los interruptores se excede ese interruptor se abre y la salida el ctrica a ese recept culo se pierde Lea No sobrecargue el generador con mucho cuidado 2 9 ARRANQUE DE MOTORES DE ARRANQUE ELECTRICO AADVERTENCIA Nunca arranque ni detenga el motor con los dispositivos el ctricos conectados a los recept culos encendidos Desconecte todas las cargas el ctricas de los recept culos de la unidad antes de arrancar el motor Aseg rese de que la unidad est en una posici n nivelada Abra la v lvula de cierre del combustible figura 9 Mueva la palanca de CHOKE del motor a la posici n FULL CHOKE completo Figura 10 Para arrancar el motor mantenga presio
137. tuation ou une action dangereuse qui si elle n est pas vit e pourrait entra ner la mort ou des blessures graves ATTENTION Indique une situation ou une action dangereuse qui si elle n est pas vit e entra nera des blessures l g res ou mod r es REMARQUE Les remarques contiennent des informations suppl mentaires importantes relatives une proc dure et se trouvent dans le corps de texte r gulier de ce manuel Ces avertissements de s curit ne peuvent pas liminer les dangers qu ils signalent Le sens commun et le respect strict des instructions sp ciales lors de l action ou l entretien sont essentiels pour viter les accidents Quatre symboles de s curit couramment utilis s accompagnent les blocs DANGER AVERTISSEMENT et ATTENTION Chacun indique le type d informations suivant Ce symbole indique des informations importantes relatives la s curit qui si elles ne sont pas suivies pourraient mettre en danger la s curit personnelle et ou les biens f Ce symbole indique un risque potentiel 3 d explosion A symbole indique un risque potentiel d incendie Ce symbole indique un risque potentiel d lectrocution DANGERS G N RAUX e jamais faire fonctionner dans un espace clos ou l int rieur e Pour des raisons de s curit le fabricant recommande que la maintenance de cet quipement soit effectu e par un d positaire agr Inspecter r guli rement le g n rateur
138. ual shall be warranted for the ECS Warranty Period A statement in the Owner s Manual to the effect of repair or replace as necessary shall not reduce the ECS Warranty Period Any such part repaired or replaced under the ECS Warranty shall be warranted for the remainder of the ECS Warranty Period Any warranted part that is scheduled for replacement as required maintenance in the Owner s Manual shall be warranted for the period of time prior to first scheduled replacement point for that part If the part fails prior to the first scheduled replacement the part shall be repaired or replaced by Generac according to Subsection 4 below Any such emissions related part repaired or replaced under the ECS warranty shall be warranted for the remainder of the period prior to the first scheduled replacement point for that part Repair or replacement of any warranted emissions related part under this ECS Warranty shall be performed at no charge to the owner at a Generac Authorized Warranty Service Facility Notwithstanding the provisions of subsection 4 above warranty services or repairs must be provided at Generac Authorized Service Facilities When the engine is inspected by a Generac Authorized Warranty Service Facility the purchaser owner shall not be held responsible for diagnostic costs if the repair is deemed warrantable Throughout the ECS Warranty Period Generac shall maintain a supply of warranted emission related parts sufficient to meet the
139. ues locaux peuvent galement exiger la bonne mise la terre de l unit cette fin brancher un fil toronn en cuivre de 10 AWG calibre am ricain des fils la borne de mise la terre et une tige en cuivre conduite la terre ou une tige la terre lectrode en laiton fournit une protection appropri e contre les lectrocutions Cependant les codes locaux peuvent fortement varier Consulter un lectricien local pour conna tre les exigences de mise la terre dans la r gion REMARQUE Tous les chiffres sont arrondis Voir les tiquettes sur l unit pour conna tre les exigences de wattage Sch ma 7 Mise la terre du g n rateur 2 6 GUIDE DE REFERENCE DE WATTAGE Dispositif oce Watts de fonctionnement Climatiseur 12 000 1700 Climatiseur 24 000 3 800 Climatiseur 40 000 6 000 Chargeur de batterie 20 500 Ponceuse bande 3 1 000 SIR A CHANG Lm 1 200 Scie circulaire 6 5 po 800 1 000 S che linge lectrique 5 750 La bonne mise la terre du g n rateur aidera emp cher une S amp che linge 0 7 700 lectrocution en cas de condition de d faut de mise la terre dans le Machine laver sus 1150 g n rat
140. uilds up in ungrounded devices 2 4 2 CONNECTING ELECTRICAL LOADS DO NOT connect 240 Volt loads to 120 Volt receptacles DO NOT connect 3 phase loads to the generator DO NOT connect 50 Hz loads to the generator Let engine stabilize and warm up for a few minutes after starting Plug in and turn on the desired 120 or 240 Volt AC single phase 60 Hz electrical loads Add up the rated watts or amps of all loads to be connected at one time This total should not be greater than a the rated wattage amperage capacity of the generator or b circuit breaker rating of the receptacle supplying the power See Don t Overload the Generator 2 5 DON T OVERLOAD THE GENERATOR Overloading a generator in excess of its rated wattage capacity can result in damage to the generator and to connected electrical devices Observe the following to prevent overloading the unit Add up the total wattage of all electrical devices to be connected at one time This total should NOT be greater than the generator s wattage capacity The rated wattage of lights can be taken from light bulbs The rated wattage of tools appliances and motors can usually be found on a data label or decal affixed to the device If the appliance tool or motor does not give wattage multiply volts times ampere rating to determine watts volts x amps watts Some electric motors such as induction types require about three times more watts of power for starting than for runn
141. uptor de circuito de presionar para reiniciar de 20 amperios figura 5 Use cada una de las tomas para alimentar cargas el ctricas de 120 volts monof sicas de 60 Ha que requieran hasta una potencia combinada de 2 400 vatios 2 4 Kw o 20 amperios de corriente Use s lo juegos de cables de alta calidad bien aislados de tres conductores con conexi n a tierra para 125 voltios a 20 amperios o m s Mantengalos cables de extensi n lo m s cortos posible preferiblemente menos de 15 pies 5 metros de largo para evitar ca das de voltaje y posible sobrecalentamiento de los cables Figura 5 recept culo d plex de 120 Volt AC 20 Amp 2 3 2 RECEPT CULO 120 240 VAC 30 Use conector NEMA 114 30 con este recept culo girar para cerrar abrir Conecte un juego de cables de 4 conductores con conexi n a tierra al conector y a la carga deseada El cable deber ser de 250 VAC y 30 Amperios nominal o m s figura 6 26 Figura 6 Recept culo de 120 240 VAC 30 Amp 120V 240V 30A Use este recept culo para operar cargas monofasicas de 120 Voltios AC a 60 Hz que requieran hasta 3600 vatios 3 6 Kw de potencia a 30 amperios 240 60 hz monof sicas que requieran hasta 7200 vatios 7 2 KW de potencia a 30 amperios Esta toma est protegida por dos interruptores de circuito de presionar para reiniciar
142. ur le produit e Se familiariser avec ce manuel et l unit avant de l utiliser Le fabricant ne peut pas anticiper toutes les situations possibles qui peuvent impliquer un danger Les avertissements de ce manuel et figurant sur les tiquettes et les autocollants appos s sur l unit sont toutefois pas exhaustifs Si vous suivez une proc dure une m thode de travail ou une technique de fonctionnement que le fabricant ne recommande pas en particulier assurez vous qu elle est sans danger pour les autres S assurer que la proc dure la m thode de travail ou la technique de fonctionnement choisie ne rende pas le g n rateur dangereux LES INFORMATIONS CONTENUES DANS LE PRESENT MANUEL SE BASENT SUR LES MACHINES EN PRODUCTION AU MOMENT DE LA PUBLICATION GENERAC SE RESERVE LE DROIT DE MODIFIER CE MANUEL TOUT MOMENT R GLES DE S CURIT Dans tout ce manuel et sur les tiquettes et sur les autocollants appos s sur le g n rateur les blocs DANGER AVERTISSEMENT ATTENTION et REMARQUE servent alerter le personnel d instructions sp ciales au sujet d une op ration sp cifique qui peut s av rer dangereuse si elle n est pas effectu e correctement ou avec pr caution Les respecter attentivement Leurs d finitions sont les suivantes DANGER INDIQUE UNE SITUATION OU UNE ACTION DANGEREUSE QUI SI ELLE N EST PAS EVITEE ENTRAINERA LA MORT OU DES BLESSURES GRAVES AVERTISSEMENT Indique une si
143. ur tous les dispositifs m caniques les moteurs Generac n cessitent une r paration et un remplacement p riodiques de leurs pi ces pour fonctionner comme pr vu La pr sente garantie ne couvre pas les r parations lorsque le probl me de la ou les pi ce s ou du moteur d coule d une utilisation normale Les d faillances caus es par toute cause ext rieure ou tout cas de force majeure tel qu un choc un vol un acte de vandalisme une meute une guerre un holocauste nucl aire un incendie un gel la foudre un s isme une temp te la gr le une ruption volcanique l eau ou une inondation une tornade ou un ouragan Les dommages dus des rongeurs et ou insectes Les produits modifi s ou alt r s d une facon n ayant pas t autoris e par crit par Generac Les dommages accessoires importants ou indirects caus s par des d faillances mat rielles ou de fabrication ou par tout retard de r paration ou de remplacement de la ou des pi ce s d fectueuses Les d faillances dues une mauvaise application Les frais de t l phone de t l phone portable de fax d acc s Internet ou d autres moyens de communication Les d penses li es l instruction du client ou au d pannage lorsqu aucun d faut n est d tect Les quipements lou s utilis s pendant la r alisation des r parations dans le cadre de la garantie Les frais de transport de nuit ou d envoi sp cial de la ou des pi ce s de rechange
144. verload the Generator carefully 2 9 STARTING ELECTRIC START ENGINES WARNING Never start or stop engine with electrical devices plugged into the receptacles AND devices turned on Unplug all electrical loads from the units receptacles before starting the engine e Make sure the unit is in a level position Open the fuel shut off valve Figures 9 Move engine CHOKE knob outward to FULL CHOKE position Figure 10 To start engine press and hold the Start Run Stop switch in the Start position The engine will crank and attempt to start When the engine starts release the switch to the run position When the engine starts move choke knob to 1 2 Choke position until the engine runs smoothly and then fully in to the Run position If engine falters move choke knob back out to 1 2 Choke position until the engine runs smoothly and then to Run position This generator is also equipped with manual recoil starter which may be used if the battery is discharged NOTE The switch must be in the RUN position To start manually firmly grasp the recoil handle and pull slowly until increased resistance is felt Pull rapidly up and away to start engine Then follow the same choke sequence NOTE If engine fires but does not continue to run move choke lever to FULL CHOKE and repeat starting instructions IMPORTANT Do not overload the generator Also do not overload individual
145. y seca Opere y almacene la unidad en un ambiente limpio y seco donde no est expuesta a excesivo polvo suciedad humedad ni vapores corrosivos Las ranuras de aire de enfriamiento en el generador no deber n obstruirse con nieve hojas ni ning n material extra o Revise la limpieza del generador frecuentemente y limpielo cuando el polvo suciedad humedad y otras sustancias extra as sean visibles en su superficie exterior ACUIDADO Nunca inserte ning n objeto ni herramienta a trav s de las ranuras de aire de refrigeraci n a n si el motor no est funcionando NOTA NO use una manguera de jard n para limpiar el generador El agua puede ingresar al sistema de combustible del motor y causar problemas Adicionalmente si el agua ingresa al generador a trav s de las ranuras de aire algo del agua ser retenida en vac os o grietas del aislamiento del bobinado del rotor y estator La acumulaci n del agua y el polvo en los bobinados internos del generador eventualmente disminuir n la resistencia de aislamiento de esos bobinados 3 3 2 PARA LIMPIAR EL GENERADOR Useun trapo h medo para limpiar las superficies exteriores Unaescobilla suave de cerdas puede usarse para soltar suciedades pegadas aceite etc Puede usarse una aspiradora para levantar suciedad y restos Se puede usar una baja presi n de aire que no exceda las 25 psi para soplar la suciedad Inspeccione las ranuras de aire de ventilaci n y las abertura
146. zado por Generac 5 No obstante las disposiciones de la subsecci n 4 arriba indicadas los servicios o reparaciones por garant a deben ser proporcionados en una instalaci n de servicio autorizada por Generac 6 Cuando el motor sea inspeccionado por un centro de servicio de garant a autorizado de Generac el propietario comprador no ser responsable de los costos de diagn stico si la reparaci n se considera dentro de la garant a 7 A lo largo del periodo de garant a ECS Generac mantendr un suministro de partes garantizadas relacionadas a las emisiones suficiente para cumplir la demanda esperada para tales repuestos 8 Cualquier repuesto relacionado a la emisi n autorizado y aprobado por Generac puede usarse en la ejecuci n de cualquier reparaci n o mantenimiento de garant a ECS y se proporcionar sin costo al comprador propietario Dicho uso no reducir las obligaciones de garant a ECS de Generac 9 Los repuestos no aprobados a adidos modificados falsos y o del mercado negro no se pueden usar para modificar reparar un motor Generac Dicho uso invalida esta garant a ECS y ser base suficiente para no aceptar un reclamo por garant a ECS Generac no podr ser declarado responsable por fallas de cualquier parte garantizada de un equipo Generac causadas por el uso de tales repuestos no aprobados a adidos modificados falsos y o del mercado negro LAS PARTES RELACIONADAS A LA EMISI N PUEDEN INCLUIR LO SIGUIENTE SI S
Download Pdf Manuals