Home
sable premium slow speed e type attachments & latch heads
Contents
1. 1 Remove Attachment from Air Motor 2 Remove Head from Attachment 3 Apply lubricant into back end of each Attachment Head using enclosed lube nozzle and reapply head to attachment and attachment to Air Motor 4 Run Air Motor Attachment and Head at normal speed for 10 seconds 5 Wipe off excess oil from Attachment and Head surface AUTOCLAVING PROCEDURE IMPORTANT NOTE These products do not come sterilized from the manufacturer It is also recommended that the products be sterilized before each use Remove attachment from Motor Remove head from Attachment Wipe off debris from head and attachment using alcohol soaked rag use only Phnolic Alcohol or alcohol based cleaning agents Lubricate attachment head refer to lubrication section Place product in an FDA HC cleared sterilization pouch and seal Autoclave for 20 minutes at a temperature of 135 degrees 275 degrees Fahrenheit Leave Attachment or Head in sterilization pouch until needed Ensure Attachment Head is stored in a sterile environment until use Before use run Attachment Head for 10 seconds to expel any water wipe dry with a sterile wipe ATTENTION This is a precision instrument Do not drop or apply excessive force when handling CYCLES The Attachment Head can be subject to 250 cycles Performed Sterilization Process i SO So AY Pe per EN ISO 7785 2 requirement 5 5 before showing signs of deterioration WARANTY INFORMATION The Sable Premium Slow
2. INDUSTRIES gt SABLE PREMIUM SLOW SPEED E TYPE ATTACHMENTS amp LATCH HEADS MAINTENANCE AND CLEANING MANUAL Dear Preferred Customer Sable Industries Inc is confident that you will benefit greatly from working with your new quality product Please read the entire manual to ensure the safe operation and guaranteeing maximum performance from your Sable Premium Slowspeed Products Indication for use Sable Industries Inc Premium Slowspeed Products are indicated for general dentistry Please retain this manual as your proof of purchase MODEL NO DESCRIPTION 1610201 1 1 Contra Angle with Internal Air amp Water 1610301 1 1 Straight Nosecone with Internal Air amp Water 1610801 Ball Bearing Swing Latch Head 1610802 Ball Bearing Push Button Latch Head 1610299 1 1 Ball Bearing Fiber Optic Contra Angle w Internal air water SAFETY PRECAUTIONS 1 Always exercise extreme caution when operating your Premium Slowspeed Products 2 Always inspect your Premium Slowspeed Products thoroughly before each use 3 Do not depress the push button on the head while in use as it could cause the head to over heat which could in turn burn the soft tissue in the patient s mouth It could also cause the bur tool to eject which would cause serious injury to the Patient 4 Ensure proper burs are used for specific product Use only burs that are DIN EN ISO 1797 1 norm and are made from hardened steel 5 Do not use burs that are bent worn or show an
3. Speed Attachment Head is warranted to be free of manufacturing defects for a period of 12 months from date of purchase Warranty is conditional on proper use and maintenance of Attachment Head Warranty is limited to repair or replacement at manufacturer s discretion Under no circumstances will the manufacturer be held responsible for incremental or consequential damages Note Heads Attachments should be repaired by an authorized Repair Service Not doing so could nullify your product warranty and also compromise product performance See your dealer for further information Please contact point of purchase authorized distributor for warranty repair Sable Industries Inc 100 Campbell Ave Suite 5 File no SablePremiumSlowSpeedEtyp1 PPIS1009 Rev B Kitchener Ontario Canada Date 7 15 08 N2H 4X8 PRINTED IN CANADA INDUSTRIES ABLE MANUEL D ENTRETIEN DES ATTACHEMENTS DE TYPE E T TE LOCQUET BASSE VITESSE SABLE PREMIUM Ch re Client le Nous sommes convaincus chez Sable Industries Inc que notre nouveau produit de qualit Vous procurera un grand avantge Veuillez lire attentivement le mode d emploi afin de faire fonctionner l instrument en toute s curit et de profiter pleinment de la performance qu un innstrument a basse vitessse de qualit Sable peut offrir Mode d emploi Les instruments basse vitess de qualit de Sable Industries Inc sont recomad s pour la medicine dentaire en general Veuillez conser
4. ant la manipulation CYCLES L accessoire la t te peut supporter 250 cycles processus de st rilisation conformes au crit re 5 5 de la norme EN ISO 7785 2 avant de montrer des signes d usure INFORMATION SUR LA GARANTIE L attachement t te locquet basse vitesse Sable Premium est garantie contre tout d faut de fabrication pour une p riode de 12 mois de la date d achat La garantie est conditionnelle une utilisation et un entretien ad quat de la pi ce main La garantie se limite la r paration ou au remplacement de la pi ce d fectueuse la discr tion du manufacturier Le manufacturier n assume aucune responsabilit pour les dommages fortuits ou indirects Contactez le distributeur autoris pour la r paration sous garantie Sable Industries Inc 100 Campbell Ave Suite 5 Cee ee Kitchener Ontario Canada Date 07 15 08 N2H 4X8 PRINTED IN CANADA
5. es normes ISO International Standard Organization 2 Se rattachent a tous les moteurs a air de type E ISO 3 Autoclavable 4 Les attachements ont l air et l eau int gr s 5 Le contre angle 1610201 est compatible avec les t tes 1600801 et 1610802 6 1610299 CA est en fribre optique et s adapte aux t tes Sable 1610802 SPECIFICATIONS 1 Connexion avec les moteurs air Standard ISO 2 M thode de st rilisation Autoclave M THODE D UTILISATION 1 Enclencher l attachement sur l axe du moteur de type E jusqu l enclanchement 2 Pour retirer l attachement tirer sur la pi ce en appuyant sur le bouton situ l ext rieur du moteur 3 La direction de l op ration est d termin e par le moteur air 4 Lib rer le mandrin du c ne droit en tournant la bague tout en vous assurant qu elle est barr e dans sa position originale 5 Ins rer la fraise tournez compl tement la bague dans la direction oppos e 6 Pour attacher la t te au contre angle touner la bague compl tement vers la gauche ins rer la t te de fa on ce que l ajustement soit ad quat avec l entaille du coude du contre angle 7 Utilisez uniquement de l air comprim sec propre et exempt de contaminant 8 R glez la pression de l air de 30 451bpo2 LUBRIFICATION n d N UTILISER QUE DU LUBRIFIANT POUR PIECE A MAIN AUTOCLAVABLE 1 Retirer l attachement du moteur 2 Retirer la t te de l attachement 3 Appliquer du lubr
6. ifiant dans l extr mit arri re de chaque attachement t te utilisant le bec lubrifiant ci inclus et rattacher la t te l attachement et l attachement au moteur air 4 Faire fonctionner le moteur et l attachement la vitesse normale pendant 10 secondes 5 Essuyer l huile exc dentaire de la surface de l attachement PROCEDURE DE STERILISATION A L AUTOCLAVE 1 Retirer l attachement du moteur 2 Retirer la t te de l attachement 3 liminer les d bris de la surface de l attachement avec un linge imbib d alcool N utilisez uniquement que de l alcool ph nolique ou de l alcool base d agents nettoyants 4 Lubrifier l accessoire la t te reportez vous la rubrique Lubrification 5 Rangez l instrument dans une pochette st rilis e transparente autoris e par la FDA ou SC et fermez herm tiquement 6 Mettez dan l autoclave pendant 20 minutes une temperature de 135 degr s Celsius 275 degr s Fahrenheit 7 Laissez l accessoire ou la t te dans un milieu sterile jusqu au moment de l utiliser 8 Conservez l accessoire t te dans un milieu st rile jusqu au moment de l utiliser 9 Faites tourner l accessoire t te pendant 10 secondes avant de l utiliser afin d expulser l eau pouvant tre rest e Ass chez avec un chiffon st rile 5 Autoclaver pendant 20 minutes 135 C ATTENTION Ceci est un instrument de pr cision Ne le laissez pas tomber et n exercez pas une force excessive pend
7. ver ce manuel comme preuve d achat MODEL NO DESCRIPTION 1610201 1 1 Contre angle avec air eau int gr s 1610301 1 1 C ne droit avec air eau int gr s 1610801 T te locquet sur roulement billes 1610802 T te locquet bouton poussoir sur roulement billes 1610299 1 1 Roulemnt billes en fibre optique contre angle avec air eau interne MESURES DE SECURITE 1 Soyez toujours extr mement prudent lors de l utilisation d un basse vitess de qualit 2 V rifiez toujours soigenusement vos instruments basse vitess de qualit avant chaque utilisation 3 N enfoncez pas le bouton poussoir sur la t te lorsque vous l utilisez car la t te pourrait surchauffer ce qui risquerait de br ler les chairs tendres dans la bouche du patient La fraiseuse purrait aussi tre ject e causant de graves bles sures au patient 4 Utilisez les fraises appropri es sp cifiques l instrument Utilisez uniquement des fraises respectant la norme DIN EN ISO 1797 1 fabriqu es en acier tremp 5 N utilisez pas de fraises courb es us es ou pr sentant des signes d usure 6 Utilisez toujours un EPI quipement de Protection Individuel lorsque vous utilisez et nettoyez vos instruments basse vitesse de qualit Sable Reportez vous la Loi sure la sant et la s curit au travail vous concernant ou aux autres directives sp cifiques sur ordonnances de s curit CARACTERISTIQUES 1 Les attachements rencontrent l
8. y signs of damaged 6 Always use PPE Proper Protective Equipment when operating and cleaning your Sable Premium Slow Speed Products See your Occupational Health and Safety Act or other safety ordinances for specific instructions FEATURES 1 Attachments conform to International Standard Organization ISO Specifications 2 Attachments are compatible to all E type ISO Air Motors 3 Autoclavable 4 Attachments have Internal Air amp Water 5 1610201 CA Accepts Sable 1610801 amp 1610802 Heads 6 1610299 CA is Fiber Optic and accepts Sable 1610802 Heads SPECIFICATIONS 1 Connection with Air Motor ISO Standard 2 Method of Sterilization Autoclave HOW TO USE 1 Slide Attachment onto shaft of E Type Air Motor until locked in place 2 To remove Attachment pull Attachment pushing release button located on the exterior of Air Motor 3 Direction of operation is determined by Air Motor 4 Release chuck of Straight Nosecone by rotating collet fully to right 5 Insert bur rotate collet fully in opposite direction 6 To attach heads to CA rotate collet ring fully to left and insert head so head fits snugly with notch in CA elbow Release collet ring ensuring ring is locked in its original position 7 Use only dry clean contaminate free compressed air 8 Set air pressure for 30 to 45 psi LUBRICATION Use only FDA HC cleared handpiece lubrication Observe all instructions and precautions associated with the lubricant
Download Pdf Manuals
Related Search
Related Contents
Channel Isolated Thermocouple Input Module User`s Manual User`s Manual - Overam Computing HP LaserJet Enterprise flow M830z KOHLER K-9516-PB Installation Guide 1756-PM003H-EN-E, SFC and ST Programming Languages "取扱説明書" HP FZ332AA rechargeable battery Snapper LT300 User's Manual Copyright © All rights reserved.