Home
Oxygen Sensor Removal & Installation Instructions
Contents
1. SIGNAL BLUE e SIGNAL GROUND ie ROUND TER WHITE 4 CONNECTOR SIDE HEATER BLACK SENSOR SIDE Fig 1 ACAUTION Refer to the appropriate connector illustration for wiring connections specific to your vehicle If in doubt use the factory service manual to prevent improper connections which may damage the vehicle ECU 7 Trim blue signal wire DENSO sensor side approximately a 3 back then strip 1 4 of insulation from the wire and gt 1 4 i its corresponding wire connector side See Fig 2 Trim 1 i one black heater wire DENSO sensor side approximately GL E 2 back and its corresponding wire connector side approximately 1 back Trim the other black heater wire Fi a a k g 2 sensor side approximately 1 and its corresponding wire connector side back approximately 2 Trim the remaining wire connector side back approximately 3 and strip 1 4 of insulation from the wire and the white ground wire sensor side NOTE Polarity is unimportant on heater wire connection 8 Slide the heat shrink tube over the sensor wire s 9 Strip 1 4 of insulation from each wire then insert corresponding wire ends into butt connectors and crimp with suitable crimping tool ACAUTION If there is any question about wire connection consult the manufacturers vehicle service manual 10 Center heat shrink tube over butt connec
2. 2 D brancher le fil de la sonde oxyg ne au niveau du faisceau de c bles du v hicule Noter le parcours du c ble de la sonde oxyg ne 3 D poser la sonde oxyg ne l aide du ou des outils appropri s cl cliquet ou douille 4 V rifier les filets sur le collecteur canalisation d chappement pour s assurer qu ils ne sont pas endommag s Si n cessaire utiliser le taraud ad quat pour nettoyer et r parer les filets 5 Comparer la sonde oxyg ne originale la nouvelle sonde au niveau de la taille du filet du connecteur du nombre de fils et de la longueur globale 6 Les deux sondes c te c te couper la sonde originale de fa on ce que la longueur globale augmente de 7 6 cm 10 cm Voir fig 1 Cela permet de faire des branchements intervalles r guliers la conduite thermo r tractable se fixe aux branchements en bout de connecteur et la longueur globale finale correspond la longueur initiale Signal Bleu i Chauffage Noir C te Sonde A AVERTISSEMENT Se r f rer au sch ma du connecteur ad quat pour conna tre les branchements de c bles sp cifiques un v hicule donn En cas de doute se reporter au manuel d entretien du fabricant pour viter de faire de mauvais branchements qui pourraient endommager l ECU du v hicule 7 Couper le fil de signal bleu c t de sonde de DENSO approximativement
3. bleu OE Heater White OE Calentador Blanco OE chauffage blanc Universal Black Universal Negro Universel noir OE Heater White OE Calentador Blanco OE chauffage blanc Universal Black Universal Negro Universel noir ISUZU 4 WIRE WEATHERPACK CONN Isuzu de 4 cables Conector Weatherpack 4 fils pour Isuzu connecteur Weatherpack OE Signal Blue OE Se al Azul OE signal bleu Universal Blue Universal Azul Universel bleu OE Heater Black OE Heater Black OE Calentador Negro OE chauffage noir Universal Black Universal Negro Universel noir OE Calentador Negro OE chauffage noir Universal Black Universal Negro Universel noir BMW 4 WIRE BMW de 4 cables 4 fils pour BMW OE Heater White OE Ground White OE Tierra Blanco OE signal blanc Universal White Universal Blanco Universel blanc OE Heater White OE Calentador Blanco OE chauffage blanc Universal Black Universal Negro Universel noir OE Calentador Blanco OE chauffage blanc Universal Black Universal Negro Universel noir OE Ground Gray OE Tierra Gris OE masse gris Universal White Universal Blanco Universel blanc OE Signal Black OE Se al Negro OE signal noir Universal Blue Universal Azul Universel bleu MAZDA 4 WIRE Mazda de 4 cables 4 fils Mazda OE Heater White OE Calentador Blanco OE chauffage blanc Universal Black Universal Negro
4. chauffage en blanc Universal Black OE Heater White Universal Negro OE Calentador Blanco Universel noir OE chauffage en blanc Universal Black Universal Negro Universel noir OE Heater White OE Calentador Blanco OE chauffage en blanc Universal Black Universal Negro Universel noir OE Ground Gray OE Signal Black OE Ground Gray OE Tierra Gris OE Se al Negro OE Tierra Gris OE masse en gris OE signal noir OE masse en gris Universal White Universal Blue Universal White Universal Blanco Universal Azul Universal Blanco Universal blanc Universel bleu Universal blanc CHRYSLER 4 WIRE Chrysler de 4 cables 4 fils pour Chrysler OE Heater White OE Calentador Blanco OE Heater White OE Calentador Blanco OE chauffage en blanc Universal Black OE chauffage en blanc Universal Black Universal Negro Universel noir Universal Negro Universel noir OE Ground Gray OE Tierra Gris OE masse en gris Universal White Universal Blanco Universal blanc OE Signal Black OE Se al Negro OE signal noir Universal Blue Universal Azul Universel bleu FORD 4 WIRE IMPORT MAZDA APPLICATION Ford de 4 cables de importaci n Aplicaci n Mazda ae i OE Heater White ation 4 fil F Mazd rtati Application s pour Ford a impor on OE Calentador Blanco OE Ground Gray OE chauffage en blanc OE Tierra Gris Universal Black GE Signal Black OE masse en gris Universal
5. et la d pose de la sonde a oxygene OE Heater White OE Calentador Blanco OE chauffage en blanc Universal Black Universal Negro Universel noir Applications universelles a 4 fils Sont indiqu es ci apr s les tapes suivre recommand es lors de la d pose et de l installation des sondes oxyg ne Se r f rer au manuel d entretien du fabricant pour les instructions sp cifiques un v hicule donn OE Heater White OE Calentador Blanco OE chauffage en blanc Universal Black Universal Negro Universel noir OE Heater White OE Calentador Blanco OE chauffage en blanc Universal Black OE Signal Black OE Se al Negro OE Ground Gray OE signal noir OE Tierra Gris Universal Blue OE masse en gris Universal Azul Universal White Universel bleu D finition des termes A MISE EN GARDE Description des pr cautions prendre afin d viter les blessures ou la mort de l utilisateur au cours de l installation Universal Negro Universal Blanco AAAVERTISSEMENT Description des pr cautions prendre afin d viter d endommager le Universel noir Universel blanc v hicule ou ses composants des dommages pouvant se produire lors de la pose si une attention insuffisante est apport e REMARQUE Fournit des informations compl mentaires facilitant la pose GM 4 WIRE WEATHERPACK CONN GM de 3 cables Conector Weatherpack 4 fils pour GM connecteur Weather Pack MERCURY NISSAN 4
6. 7 6cm puis d nuder 0 63cm de i ya l isolation du fil et de son fil correspondant c t de i A connecteur Voir fig 2 Couper un fil noir de r chauffeur Eo FE c t de sonde de DENSO approximativement 5cm fil et son correspondant c t de connecteur approximativement fig 2 2 54cm Couper l autre fil noir de r chauffeur c t de sonde approximativement 2 54cm et son dos correspondant approximativement 5cm de fil c t de connecteur Couper le dos restant approximativement 7 6 de fil c t de connecteur et d nuder 0 62 de l isolation du fil et du fil de masse blanc c t de sonde REMARQUE La polarit n a pas d importance pour le branchement des fils de chauffage 8 Glisser la conduite thermo r tractable par dessus les fils de la sonde 9 D nuder sur 0 63 cm chaque fil puis ins rer les extr mit s de chaque fil au bout des connecteurs et sertir avec l outil de sertissage ad quat AAAVERTISSEMENT En cas de question sur le branchement des fils consulter le manuel d entretien du v hicule du fabricant 10 Centrer la conduite thermo r tractable sur les connecteurs et appliquer de la chaleur afin de rendre le branchement tanche et d viter que l eau n y p n tre Voir fig 3 Signal Bleu Signal Chauffage Chauffage Noir Masse Blanc Masse i C te Sonde C te Connecteur fig 3 Instructi
7. ATTENTION Inspect contents before opening Once this ATENCI N Inspeccionar el contenido ATTENTION V rifier le contenu avant antes de abrir Ya no d ouvrir Une fois ouvert se puede devolver este ce paquet ne peut pas paquete una vez que haya tre renvoy package has been opened it cannot be retumed sido abierto For current application updates and photos please visit www DensoAftermarket com If you have any questions concerning the above information please call DENSO Technical Support Hotline at 888 96 DENSO toll free in the United States and Canada or DENSO directly at 310 834 6352 Para obtener actualizaciones sobre las aplicaciones actuales y fotografias visite www DensoAftermarket com Si tiene cualquier pregunta referente a la informaci n arriba indicada llame a la l nea de urgencias de Soporte t cnico DENSO al 888 96 DENSO sin costo en los Estados Unidos y Canad o a DENSO directamente al 310 834 6352 Pour les mises a jour d application et photos visitez le site www DensoAftermarket com Si vous avez des questions concernant l information ci dessus veuillez appeler l Assistance technique DENSO au 888 96 DENSO sans frais aux tats Unis et au Canada ou directement DENSO au 310 834 6352 3900 Via Oro Avenue Long Beach California 90810 LA990009 1410 1 DENSO first time fit Oxygen Sensor Removal amp Installation Instructions Universal 4 Wire Applicatio
8. Blanco OE Ground Green Green or White o signa pang OE Tierra Azul niversal Blue i Whi Verde o Blanco Universal Azul Universal White OE masse bleu Universel bleu Universel blanc OE Signal Blue White or Yellow OE Se al Azul vert ou blanc Universal White Universal blanco Universel blanc OE signal bleu blanc ou jaune Universal Blue Universal Azul Universel bleu OE Heater Black or Yellow OE Heater Black OE Calentador Negro OE chauffage noir ou jaune Universal Black Universal Black Universal Neg ro Universal Negro Universel noir Universel noir o Amarillo OE chauffage noir OE Tierra Verde OE masse vert Universal blanco OE Calentador Negro OE Heater Black OE Calentador Negro OE chauffage noir Universal Black Universal Negro Universel noir LA990009 1410 1 CHRYSLER 4 WIRE Chrysler de 4 cables 4 fils pour Chrysler LATE FORD 4 WIRE SMALL CONN Ford reciente de 4 cables Conector Peque o 4 fils r cent pour Ford petit connecteur OE Ground Gray OE Tierra Gris OE masse en gris Universal White Universal Blanco Universel blanc DENSO first time fit OE Heater White OE Calentador Blanco OE chauffage en blanc Universal Black Universal Negro Universel noir OE Signal Black OE Sefial Negro OE signal noir Universal Blue Universal Azul Universel bleu Instructions pour l installation
9. Negro GE Se al Negro Universal White Universel noir OE signal noir Universal Blanco Universal Blue Universal blanc Universal Azul Universel bleu OE Signal Black OE Se al Negro OE Ground Gray OE Tierra Gris OE masse en gris Universal White Universal Blanco Universal blanc OE signal noir Universal Blue Universal Azul Universel bleu OE Heater White OE Calentador Blanco GE Heater White OE chauffage en blanc GE Calentador Blanco Universal Black OE chauffage en blanc Universal Negro Universal Black Universel noir Universal Negro Universel noir
10. OE Signal Black Universel noir OE Se al Negro OE signal noir Universal Blue Universal Azul Universel bleu OE Ground Gray OE Tierra Gris OE masse en gris Universal White Universal Blanco Universel blanc OE Heater White OE Calentador Blanco OE chauffage blanc Universal Black Universal Negro Universel noir BMW 4 WIRE BMW de 4 cables 4 fils pour BMW OE Ground Gray OE Tierra Gris OE masse gris Universal White Universal Blanco OE Heater White Universel blanc OE Calentador Blanco OE chauffage blanc Universal Black Universal Negro Universel noir OE Heater White OE Calentador Blanco OE chauffage blanc Universal Black Universal Negro OE Signal Black Universel noir OE Se al Negro OE signal noir Universal Blue Universal Azul Universel bleu LA990009 1410 1 DENSO first time fit Instrucciones para instalar y retirar el sensor de oxigeno Aplicaciones universales de 4 cables Estos son los pasos que se recomienda seguir cuando se retiren o instalen los sensores de ox geno Para instrucciones m s precisas para su veh culo consultar el manual de servicio del fabricante del mismo Definici n de t rminos AADVERTENCIA Describe precauciones que deben ser tomadas con el fin de prevenir lesiones o la muerte del usuario durante la instalaci n APRECAUCION Describe percauciones que deben ser tomadas con el fin de prevenir d
11. WIRE SENSORS Mercury Nissan Sensor de 4 cables Capteurs 4 fils pour Mercury Nissan OE Signal Black or Purple OE Se al Negro o P rpura OE signal noir ou violet Universal Blue Universal Azul Universel bleu OE Heater Black Brown or Pink OE Heater Black Brown or Pink OE Calentador Negro Caf o Rosa OE chauffage noir marron ou rose Universal Black Universal Negro Universel noir OE Calentador Negro Caf o Rosa OE chauffage noir marron ou rose Universal Black Universal Negro Universel noir OE Ground Tan OE Tierra Canela OE masse en brun Universal White Universal Blanco Universel blanc OE Ground Gray OE Tierra Gris OE masse en gris Universal White Universal Blanco Universel blanc OE Heater White OE Calentador Blanco OE chauffage en blanc Universal Black Universal Negro Universel noir OE Signal Black OE Se al Negro OE signal noir Universal Blue Universal Azul Universel bleu OE Heater White OE Calentador Blanco OE chauffage en blanc Universal Black Universal Negro Universel noir OE Heater White OE Calentador Blanco OE chauffage en blanc Universal Black Universal Negro Universel noir OE Ground Gray OE Tierra Gris OE masse en gris Universal White Universal Blanco Universel blanc Instructions pour la d pose 1 Le syst me d chappement doit tre temp rature ambiante
12. a os al veh culo o a sus componentes que podr an ocurrir durante la instalaci n si no se tiene suficiente cuidado NOTA Provee informaci n adicional que facilita el trabajo de instalaci n Instrucciones para retirar el sensor 1 El sistema de escape debe estar a temperatura ambiente 2 Desconectar el cable del sensor de ox geno del arn s de cables del veh culo Fijarse en la ruta del cable del sensor de ox geno 3 Retirar el sensor de ox geno con la o las herramientas apropiadas Trinquete y dado o llave inglesa 4 Asegurarse que la rosca del tubo del m ltiple de escape no est da ada Si fuera necesario usar la tarraja correcta para limpiar y reparar la rosca 5 Comparar el sensor original con el o los nuevos para verificar el tama o de la rosca conector n mero de cables y largo total 6 Teniendo los dos sensores lado a lado cortar el sensor original de manera que la longitud total sea de 3 a 4 pulgadas mayor que antes ver figura 1 Esto permitir hacer las conexiones a intervalos regulares de manera que el tubo termoretr ctil se ajuste sobre las conexiones de la cabeza del conector y la longitud final coincida con la original Calentador Conector Calentador Negro Tierra Blanco Detector APRECAUCI N Consultar las terminales espec ficas para su veh culo en la ilustraci n correspondiente del con
13. ector En caso de duda consultar el manual de servicio del fabricante a fin de evitar conexiones incorrectas que podr an da ar el ECU del veh culo 7 Cortar el alambre de se al azul lado del sensor de 7 DENSO aproximadamente 3 despu s corte 1 4 del 14 i aislamiento del alambre y de su alambre correspondiente i lado del conectador ver figura 2 Cortar un alambre SE negro del calentador lado del sensor de DENSO aproximadamente 2 y su correspondiente lado el figura 2 conectador aproximadamente 1 Cortar el otro alambre negro del calentador lado del sensor aproximadamente 1 y su parte correspondiente aproximadamente 2 del alambre lado del conectador Cortar la parte restante aproximadamente 3 del alambre lado del conectador y corte 1 4 del aislamiento del alambre y del alambre de tierra blanco lado del sensor NOTA La polaridad no es importante en la conexi n de los cables del calentador 8 Deslizar el tubo termoretr ctil sobre los cables del sensor 9 Retirar 1 4 del aislante de cada cable e insertar el extremo de cada cable de manera que corresponda con el de la cabeza del conector y empalmar con la herramienta adecuada APRECAUCI N En caso de duda sobre las conexiones de los cables consultar el manual de servicio del fabricante del veh culo 10 Centrar el tubo termoretr ctil sobre la cabeza del conector y aplicar calor para sellar las conexiones para que no les entre a
14. gua ver figura 3 Se al Azul i Calentador Negro Calentador Tierra Blanco Tierra Lado del Sensor Lado del Conector figura 3 Instrucciones para instalar el sensor APRECAUCI N Los sensores de ox geno son fr giles y deben tratarse con cuidado no dejarlos caer Evitar exponer el sensor a productos a base de silicona RTV 1 Antes de la instalaci n aplicar al nuevo sensor de ox geno un compuesto contra el agarrotamiento para evitar que las tuercas se agarroten con la rosca No hacerlo con los sensores con brida A ADVERTENCIA Los compuestos para evitar que las tuercas se agarroten con la rosca pueden causar imitaci n a los ojos y la piel En caso de que el producto toque la piel lavar la zona afectada con agua y jab n En caso de que entre a los ojos enjuagarlos con agua durante 15 minutos Si la imitaci n persiste consultar a un m dico En caso de tragar el producto no inducir el vomito Mantener fuera del alcance de los ni os 2 Instalar el nuevo sensor de ox geno con la mano asegur ndose de no da ar la rosca y apretar seg n las especificaciones del fabricante Para los sensores con brida usar la junta que se suministra junto con el sensor 3 Dirigir el cable del nuevo sensor por la misma ruta que el original hasta el arn s de cables del veh culo y conectarlo APRECAUCI N Mantener el cable del senso
15. ns These are recommended steps to follow when removing and installing oxygen sensors Refer to the factory service manual for specific instructions for your vehicle Definition of Terms AWARNING Describes precautions that should be observed in order to prevent injury or death to the user during installation ACAUTION Describes precautions that should be observed in order to prevent damage to the vehicle or its components which may occur during installation if sufficient care is not taken NOTE Provides additional information that facilitates installation work Removal Instructions 1 Exhaust system should be at ambient temperature 2 Disconnect the oxygen sensor wire at the vehicle wire harness Note the routing of the oxygen sensor wire 3 Remove the oxygen sensor with the appropriate tool s Ratchet 8 socket or wrench 4 Check the threads on the exhaust manifold pipe to make sure they are not damaged If necessary use the correct size tap to clean and repair the threads 5 Compare the original and the new oxygen sensor s for the correct thread size connector number of wires and overall length 6 With the two sensors laid out side by side cut off the original sensor so overall length will be 3 4 longer than before See Fig 1 This will allow connections to be made at evenly spaced intervals so the heat shrink tube can fit over the butt connections and the finished overall length to match the original
16. ons pour l installation AAVERTISSEMENT Les sondes oxyg ne sont fragiles et doivent tre manipul es avec soin ne pas les laisser tomber Eviter d exposer la sonde des produits base de silicone RTV 1 Avant de proc der l installation appliquer un enduit antigrippant sur les filets de la nouvelle sonde oxyg ne Les sondes de type embase ne sont pas concem es A MISE EN GARDE L enduit antigrippant peut provoquer des irritations au niveau de la peau et des yeux En cas de contact avec la peau laver la zone touch e l eau savonneuse En cas de contact avec les yeux rincer abondamment l eau claire pendant 15 minutes Si l imitation persiste consulter un m decin En cas d ingestion ne pas provoquer le vomissement A conserver hors de port e des enfants 2 Poser la nouvelle sonde oxyg ne la main s assurer que le filet n est pas fauss puis serrer conform ment aux indications du fabricant Pour les sondes de type embase utiliser un nouveau joint foumi avec la sonde 3 Placer le fil de la nouvelle sonde oxyg ne comme le fil initial vers le faisceau de c bles du v hicule et le brancher AAVERTISSEMENT Le fil de la sonde oxyg ne doit tre tenu loign de toutes les surfaces chaudes pi ces mobiles 6 CHRYSLER 4 WIRE FEMALE STYLE CONNECTOR Chrysler de 4 cables Conector Estilo Hembra OE Heater White Connecteur femell fils pour Chrysler OE Calentador Blanco OE
17. r de ox geno alejado de cualquier superficie Caliente y de partes m viles 4 GM 4 WIRE METRI PACK CONN GM de 4 cables Conector Metri pack 4 fils pour GM connecteur Metri pack OE Signal Purple OE Se al P rpura OE signal violet OE Heater Brown Universal Blue OE Calentador Caf OE chauffage marron Universal Black Universal Negro Universel noir OE Heater Brown OE Calentador Caf OE chauffage marron Universal Black Universal Negro Universel noir 0 OE Ground Tan OE Tierra Canela Universal White Universal Blanco Universel blanc OE Heater Brown Universal Azul Universel bleu OE chauffage brun OE Heater Brown OE Calentador Caf OE chauffage marron Universal Black Universal Negro Universel noir OE Heater Brown OE Calentador Caf OE chauffage marron Universal Black Universal Negro Universel noir OE Calentador Caf OE chauffage marron Universal Black Universal Negro Universel noir OE Signal Purple OE Se al P rpura OE signal violet OE Ground Tan Universal Blue OE Tierra Canela Universal Azul OE chauffage brun Universel bleu Universal White Universal Blanco Universel blanc ACURA HONDA 4 WIRE Acura Honda de 4 cables 4 fils pour Acura Honda L OE Ground Tan OE Tierra Canela OE chauffage brun Universal White Universal Blanco Universel blanc OE Signal White OE Ground Blue QE Se al
18. tor s and apply heat to seal the connection so water cannot enter See Fig 3 GNAL BLUE SIGNAL E BLACK HEATER GROUND WHITE GROUND SENSOR SIDE CONNECTOR SIDE Fig 3 Installation Instructions ACAUTION Oxygen sensors are fragile and must be handled with care do not drop Avoid exposing the sensor to RTV silicone based products 1 Before installation apply anti seize compound to the threads of the new oxygen sensor Disregard for flange type sensor AWARNING Anti seize compound may cause irritation to the skin or eyes In case of contact wash affected area with soap and water In case of eye contact flush with water for 15 minutes If irritation persists consult a physician If swallowed do not induce vomiting Keep out of reach of children 2 Install the new oxygen sensor by hand making sure it is not cross threaded and then torque to manufacturers specifications For flange type sensor use new gasket included with sensor 3 Route the new oxygen sensor wire along the original route to the vehicle wire harness and plug it in ACAUTION Keep the oxygen sensor wire away from any hot surfaces moving parts MITSUBISHI amp CHRYSLER IMPORT Mitsubishi y Chrysler de imporatci n Mitsubishi et Chrysler importation OE Signal Blue Black or Yellow OE Se al Azul Negro o Amarillo OE signal bleu noir ou jaune Universal Blue Universal Azul Universel ble
19. u OE Signal Blue or Yellow OE Ground White OE Se al Azul OE Tierra Blanco o Amarillo OE masse blanc OE signal bleu Universal White ou jaune Universal Blanco Universal Blue Universel blanc Universal Azul Universel bleu OE Ground Gray or Green OE Tierra Gris o Verde OE masse gris ou vert Universal White Universal Blanco Universel blanc OE Heater White OE Calentador Blanco OE chauffage blanc Universal Black Universal Negro OE Heater White Universel noir OE Calentador Blanco OE chauffage blanc Universal Black Universal Negro Universel noir OE Signal Black or Yellow OE Se al Negro o Amarillo OE signal noir ou jaune Universal Blue Universal Azul Universel bleu OE Ground White Gray or Green OE Tierra Blanco Gris o Verde OE masse blanc gris ou vert Universal White Universal Blanco Universel blanc OE Heater Black OE Calentador negro OE signal noir Universal Black Universal Negro Universel noir OE Ground White Gray or Green OE Tierra Blanco Gris o Verde OE masse blanc gris ou vert Universal White Universal Blanco Universel blanc L gt OE Heater Black or White OE Calentador negro o Blanco OE signal noir ou black OE Signal Blue Universal Black Black or Yellow Universal Negro OE Se al Azul Universel noir Negro o Amarillo OE signal bleu noir ou jaune Universal Blue Universal Azul Universel
Download Pdf Manuals
Related Search
Related Contents
Manual de Instalação e Manutenção Installation - Extranet Viewsonic Value Series VA2232WM UM10729 - NXP Semiconductors orig_greybook302.59 KB MOUSSE ISOLANTE SUPER SET-UP FOR HTML EMULATION 10 Click here to user manual for iMiX16 Pro 2SB907 (audio files) et la partie de forme d`onde Copyright © All rights reserved.