Home

XL 9ER - XL 9SR - Select Sprayers

image

Contents

1. ACCESSORIES FAULTS AND THEIR LIKELY CAUSES PRODUCT PRESENTATION XL 9 is a generator of heat by radiation Radiation technology is based on the same physical principle behind the warmth of sunlight The sun heats bodies without a flow of warm air but by waves of radiation The radiation method is becoming highly popular among professional clients because of the countless advantages it offers XL 9 was designed on the basis of this physical principle and has become irreplaceable in environ ments which require a constant even source of heat for warmth defrosting and drying In addition its extremely low noise level makes it suitable for working without having to put up with the noise that other types of heater normally produce The genera tor has rubber wheels for ease of movement and it can also be raised and set at different heights by means of eyebolts Its extended autonomy and automatic thermostat function grant the operator maximum freedom of use The external fuel tank indi cator provides an easy check on whether fuel needs topping up The S model has a dual power device that enables a more ef ficient use of the machine under different conditions and during the various seasons of the year UNPACKING AND PACKAGING UNPACKING Remove the supports used to pack the appliance Fig 1 Open top side of the box Remove the cardboard from the top Remove the supports that hold the generator to the pallet Fig 2 D
2. qui arr te le g n rateur Dans ce cas apr s avoir attendu pendant environ une minute appuyer sur le bouton Reset D Fig 5 6 et allumer de nouveau l appareil En cas de non fonctionnement les premi res op rations faire sont les suivantes 1 Contr ler que le r servoir N Fig 4 contient encore du gas oil 2 Appuyer sur le bouton RESET de pour r enclencher le dispo sitif D Fig 5 6 Si le g n rateur ne fonctionne toujours pas apr s de telles op rations consulter le paragraphe REP RAGE DES PANNES et comprendre la cause du non fonctionnement AVERTISSEMENT Avant le deuxi me allumage g n ra teur teint et froid il faut v rifier le blocage des vis blo quant le d flecteur ant rieur L Fig 4 AVERTISSEMENT La ligne lectrique d alimentation du g n rateur doit tre pourvue de mise terre et d un in terrupteur magn to thermique diff rentiel La fiche lec trique du g n rateur doit tre branch e une prise munie d un interrupteur coupe courant EXTINCTION DU G N RATEUR Mettre l interrupteur B Fig 5 sur la position OFF ou agir si connect sur le thermostat ou sur le dispositif de contr le mi nuterie en le r glant de facon ad quate La flamme s teint et la ventilation persiste jusqu l ach vement du cycle de post ventilation refroidissement AVERTISSEMENT Avant de d brancher le c ble d alimen tation de la prise attendre l ach vement du cycle de
3. la surface des composants du br leur Apr s quelques minutes la fum e dispara tra Utiliser la machine une temp rature comprise entre 30 C et 40 C XL9Heater com Distributor North America Easy Clean Systems 916 638 0828 IDENTIFICATION DES PRODUITS A B F Figure 3 Figure 6 Pi ces du br leur A R gulation volet d air B Interrupteur ON OFF lumineux C Interrupteur ON OFF seconde puissance XL 9SR D Bouton RESET E Voyant tension F Coffre br leur G Branchement thermostat H Vis I Fiche post ventilation L Appareillage contr le flamme M Transformateur N1 R glage Pression XL 9ER de la pompe N2 R glage Pression XL 9SR de la pompe O1 Pompe combustible XL 9ER Oz Pompe combustible XL 9SR P Condensateur Q Moteur R Conduit du br leur S R glage de la t te de combustion T Photor sistance U1 Sou pape lectrique 1 stade de flamme XL 9ER SR Uz Soupape lectrique 2 stade de flamme XL 9SR Figure 4 A Chambre de combustion B Trou pour le transport de l appa reil C Filtre combustible ou filtre pr chauffage en option D Refoulement combustible E Retour combustible F Bouchon ravitaillement combustible G Pied ou Roue en option H Indicateur niveau combustible I Blocage groupe combustion L D flecteur ant rieur M Bouchon vidange combustible N R servoir O Poign e pour le transport du g
4. curtains or oth er similar materials must be situated at a safe distance from these objects The minimum safety distance is that which is advised by the current regulations in the your country It is also advisable to use fireproof materials for coverings Such ma terials should be fastened in a safe manner so as to avoid their catching fire and prevent interference with the generator caused by wind Use only well ventilated areas Predispose an opening or at least an air exchange system that meets the current govern mental regulations in your area so that fresh air will be pro vided Supply the generator with the proper voltage and frequency as specified on the identification plate Use only extension cords with three wires correctly connected to a grounded plug The minimum safety distance is the distance required by the current governmental regulations in your area Place the generator in a position so that when it is hot or in function it will be on a stable and level surface so that you avoid starting a fire When you move or store the generator maintain it in a level position in order to avoid fuel loss Keep children and animals away from the generator Disconnect the generator when it is not in use When it is controlled by another device like a thermostat or a timer the heater could turn itself on at any time Never place the generator in inhabited rooms Never obstruct the aspiration or dissipat
5. n rateur P Bloc poign e Q Br leur R R gulateur inclinaison www XL9Heater com Distributor North America Easy Clean Systems 916 638 0828 4 fr COMBUSTIBLE AVERTISSEMENT Le g n rateur fonctionne SEULEMENT avec du k ros ne ou du gas oil L usage d un combustible impur peut causer Lengorgement du filtre du combustible et de l injecteur La formation de d p ts carbon s sur les lectrodes basse temp rature utiliser des additifs antigel non toxiques PRINCIPES DE FONCTIONNEMENT L air assurant une combustion correcte est produit par la rotation d un ventilateur l int rieur du br leur Le flux de l air sort par le tube du br leur et se m lange avec le combustible qui est pul v ris par une buse haute pression Le combustible pulv ris par la buse est contr l par une pompe rotative qui l aspire hors du r servoir et le pousse haute pression jusqu la buse pour la pulv risation MISE EN MARCHE ATTENTION Avant de mettre en marche le g n rateur et donc avant de le relier au courant lectrique d alimentation il faut contr ler si les caract ristiques du courant lectrique correspondent celles report es sur l tiquette d identification du g n rateur ALLUMAGE DU G N RATEUR 1 Suivre toutes les instructions relatives la s curit 2 Effectuer le ravitaillement avec du gas oil ou du k ros ne 3 Fermer le bouchon du r servoir 4 Ins rer la fiche du c
6. frais depuis l ext rieur Alimenter le g n rateur seulement avec un courant ayant la tension et la fr quence indiqu es sur l tiquette d identification Utiliser uniquement des rallonges trois fils opportun ment reli es la masse Distance minimum de s curit entre le r chauffeur et des substances combustibles selon les r glementations en vigueur dans l tat d appartenance Mettre le g n rateur chaud ou en marche sur une surface stable et plane de fa on viter les risques d incendie Quand le g n rateur est d plac ou simplement conserv le maintenir horizontal pour viter que le combustible ne s chappe Mettre le g n rateur hors de port e des enfants et des ani maux D brancher le g n rateur de la prise de courant quand il est teint Quand le r chauffeur est muni d un dispositif de contr le ther mostat ou minuterie il peut s allumer tout moment Ne jamais utiliser le g n rateur dans des pi ces fr quemment habit es Ne jamais boucher la grille d aspiration et de dissipation Quand le r chauffeur est chaud reli au courant ou en marche il ne doit jamais tre d plac manipul ravitaill ou encore sujet une quelconque intervention d entretien La fum e qui s chappe lors de la premi re combustion est due l vaporation de mati res organiques c ramiques pr sentes dans la chambre de combustion et l huile anticorro sion pr sente
7. fuel filter Flame Control device Circuit is broken Flame disk or tube Fig 12 13 14 dirty The electrical system is not compatible Ignition Transformer M Fig 6 disconnected or broken Ignition Transformer wires short circuit to ground The electrodes are not at the proper distance The electrodes short circuit to ground because they are dirty or the insulation is damaged Photo electric cell sees a strong source of light The power supply is missing a phase to the motor Fuel is not arriving to the pump No fuel in the tank Nozzle clogged The control device Thermostat or Timer is on Short circuit in Photo resistance T Fig 6 Power loss due to disconnected switch 4 or disconnected main switch due to power loss in the line The installation of the control device Thermo stat or Timer is not correct Break inside the flame control device Fuse inside the burner bonnet Low pulverisation pressure Insufficient combustible air Nozzle clogged because it is dirty or old Water in the fuel Poor quality fuel The tank is running out of fuel Clean or replace the Photo resistance Remove filter and clean it Replace the flame control the circuit Dismantle and clean it Verify the entire circuit Replace it Replace it Reposition them at the correct distance see Fig 14 Clean them or if necessary replace them Place the machine so that the li
8. post ventilation refroidissement d environ 3 minutes DISPOSITIFS DE S CURIT Le g n rateur est dot d un syst me de s curit L Fig 6 pour le contr le de la flamme Si on constate une ou plusieurs ano malies au cour du fonctionnement cet appareillage provoque le blocage du br leur et l allumage du voyant du bouton RESET D Fig 5 o 6 Le g n rateur est aussi muni d un quipement de post ventilation Cet quipement permet un refroidissement optimal et automatique de la chambre de combustion pendant une dur e d environ 3 min Avant de remettre en marche le g n rateur rep rer et liminer la cause qui a provoqu le blocage TRANSPORT ET D PLACEMENT ATTENTION Avant de soulever ou de d placer la ma chine s assurer que les bouchons du r servoir F et H Fig 3 soient bien ferm s TRANSPORT Le g n rateur peut tre facilement transport d une pi ce l autre tout comme il peut tre soulev et plac diff rents ni veaux gr ce des anneaux de fixage sp ciaux B Fig 3 ou Fig 7 M est donc possible de fixer la machine et de la soulever pour la placer aux endroits o l on doit chauffer d congeler et s cher XL9Heater com Distributor North America Easy Clean Systems 916 638 0828 Figure 7 Crochets afin d augmenter D PLACEMENT Le g n rateur peut tre muni de roues pivotantes G Fig 3 Dans ce cas si le terrain le permet il convient de pousser le g
9. E CE PREHL SENIE O ZHODE CE DEKNAPALIMA 3A CbBMECTMMOCT CE DEKNAPALIIA BIANOBIAHOCTI CE IZJAVA CE O PRIKLADNOSTI AHAQSH ZYMMOPQQOZHE CE CE ff amp HE MCS ITALY S p A Via Tione 12 37010 Pastrengo VR ITALY Product Prodotto Produkt Producto Produit Product Produto Produkt Tuote Produkt Produkt Pro dukt U3genue V robek Term k Izdelek Ur n Proizvod Gaminys lerice Toode Produsul V robok Mpoaykr Bupi6 Proizvod l Ipoi v 7 ma XL 9ER XL 9SR We declare that it is compliant with Si dichiara che conforme a Es wird als konform mit den folgenden Normen erkl rt Se declara que est en conformidad con Nous d clarons sa conformit Hierbij wordt verklaard dat het product conform is met Declara se que est em conformidade com Vi erklaerer at produktet er i overensstemmel se med Vakuutetaan olevan yhdenmukainen Man erkl rer at apparatet er i overensstemmelse med H rmed intygas det att produkten ar f renlig med f ljande O wiadcza sie ze jest zgodny z 3asiBriieM O coorBercTBuM Tpe6oBaHusMw Prohla uje se Ze je v souladu s Kijelentj k hogy a term k megfelel az al bbiaknak Izpolnjuje zahteve A a daki standartlara uygun oldu unu beyan ederiz Izjavljuje se da je u skladu s PareiSkiame kad atitinka Tiek deklar ts ka atbilst K esolevaga deklareeritakse et toode
10. EVENTATIVE MAINTENANCE SCHEDULE WARNING Before beginning any maintenance operation you must turn off the machine following the instructions in the TURNING OFF THE GENERATOR paragraph un plug the electrical alimentation by unplugging the cord from the wall plug and waiting for the generator to cool down The instructions in this paragraph regarding the time between service checks depend a lot on the cleanliness of the fuel and the type of environment the generator is used in the times giv en are for well ventilated environments with little dust and con sidering the use of clean fuel Every 50 hours of operation you must Dismantle the on line cartridge see CLEANING THE FUEL FILTER extract and clean the cartridge Every 200 hours of operation you must Dismantle the pump filter see CLEANING THE PUMP FIL TER extract and clean it Every 300 hours of operation you must Dismantle the burner and clean inside the burner s tube the flame disk and the electrodes regulating if necessary the dis tance see CLEANING OF THE BURNER CLEANING THE FUEL FILTER e Unscrew the plastic cup and extract the filtering element cartridge Clean it well with kerosene Insert the filter element back into its place and screw the cup back into the main body of the combustion filter A O rings B Plastic cup C Filtering element D Body of IN OUT of the fuel Figur 10 Filter CLEANING THE PUMP F
11. ILTER Dismantle the burner coffer F Fig 5 to identify the pump of the burner O Fig 6 Unscrew the nut A Fig 11 that blocking the filtering element to the pump Extract the filtering element C Fig 11 outside its place Clean it well with kerosene Insert the filtering element back into its place and screw the nut to the pump A Nut for blocking the pump filter D B Single elec trovalve for 4 K XL 9ER doble x electrovalve for XL 9SR C Filter D Pump Figur 11 Pomp of burner XL9Heater com Distributor North America Easy Clean Systems 916 638 0828 CLEANING THE BURNER Remove the screw H Fig 5 that blocks the burner A Fig 3 in the combustion chamber Extract the burner from the combustion chamber Fig 3 Remove the three screws B Fig 12 that hold the burner tube A Fig 12 Dismantle the tube Remove the screw C Fig 13 that holds the group diskflame electrodes and pull out the nozzle holder F Fig 14 Clean the flame disk D Fig 14 and the electrodes E Fig 14 Unscrew the nozzle G Fig 14 from the nozzle holder F Fig 14 clean it and if necessary replace it Mount the nozzle G Fig 14 in its holder Remount the group diskflame electrodes placing it at a correct distance as the illustration Fig 14 shows A B 4mm 22 mm Figur 14 D
12. STAT e XL 9ER Set the switch B Fig 5 to the ON position I It begins the period of pre ventilation and after approximately 10 seconds ones the combustion has beginning e XL 9SR WARNING Before starting the generator to make sure that the button C Fig 5 is in position Set the switch B Fig 5 to the ON position I It begins the pe riod of pre ventilation and after approximately 10 second ones the combustion has beginning For having the maximum potentiality portare set the switch C Fig 5 to the Nh position STARTING WITH A THERMOSTAT Regulate the thermostat or the control device for example a timer if connected so that it will allow the generator to function WARNING The generator can ONLY function automatically when the control device for example a Thermostat or a Timer is connected to the generator To connect the control device to the machine consult the paragraph entitled ELECTRIC DIAGRAM Before starting the machine or after the fuel line has been completely emptied the fuel flow to the nozzle should be insufficient to cause the intervention of the security device which controls the flame see the SAFETY DEVICE paragraph that stops the generator In this case after having waited approximately one minute push the Reset button D Fig 5 and 6 and start the machine If the machine isn t working you should first control the following 1 Make sure that the fuel tank N Fig 4 still contains f
13. ales ou parce que l isolant est abim La photor sistance d tecte une source de lumi re intense ll manque une phase au Moteur Le gas oil n arrive pas la pompe Il manque du gas oil dans le r servoir Injecteur bouch Dispositif de contr le Thermostat ou Minute rie ouvert Photo r sistance T Fig 6 en court circuit La tension manque cause de l interrupteur d branch de l interrupteur du compteur ayant saut ou d un manque de tension dans la ligne lectrique L installation du dispositif de contr le Ther mostat ou Minuterie n est pas correcte Panne interne l appareillage de contr le de la flamme Fusible br l l int rieur du coffre Basse pression de pulv risation Air pour la combustion insuffisant Injecteur bouch car sale ou abim Eau dans le combustible Carburant de mau vaise qualit Le combustible est en train de finir Nettoyer la Photo r sistance ou la emplacer D monter le filtre et le nettoyer D montez le d flecteur ant rieur et nettoyez l int rieur de la chambre de combustion Les d monter et les nettoyer V rifier tout le circuit 2 Le remplacer Les remplacer Les remettre dans la position recommand e Fig 14 Les nettoyer ou si n cessaire les remplacer Placez la machine en vitant la source de lumi re sur le d flecteur ant rieur Contr ler l installation lectrique Contr le
14. and eliminate the cause that blocked the machine MOVING AND TRANSPORTATION NOTICE Before raising or moving the machine ensure that the fuel tank caps F and H Fig 3 are firmly closed TRANSPORT The generator is easy to move and it may be fixed in a raised position thanks to its special eye bolt mechanism B Fig 3 or Fig 7 This enables it to be set in the most suitable position for heating defrosting and drying Figur 7 Hooks in order to raise www XL9Heater com Distributor North America Easy Clean Systems 916 638 0828 MOVEMENT Before picking up or moving the machine you must check to in sure that the tank caps G Fig 3 are tightly shut The generator may be supplied with a rotating wheel In this case if the floor ing allows it you may push the generator like a cart In the case the machine does not have rotating wheels it is necessary to unblock the hinge P Fig 4 located on one of the lateral struts of the generator Lower the handle from its resting position Fig 8 Turn the handle to the Transportation Position Fig 9 Lift the generator and position it so that it is resting on the two an terior wheels Figur 9 Position open handles WARNING Before moving the machine you must turn the machine off by following the indications provided in paragraph TURNING OFF THE GENERATOR unplug the electrical source by pulling the plug out of the wall and waiting for the generator to cool down PR
15. ble d alimentation dans une prise murale reli e la masse et ayant une tension gale celle report e sur l tiquette d identification de l appareil ALLUMAGE SANS THERMOSTAT XL 9ER Mettre l interrupteur B Fig 5 sur la position ON la p riode de pr ventilation d marre environ 10 secondes apr s le d but de la combustion XL 9SR AVERTISSEMENT Avant d actionner le g n rateur v ri fiez que l interrupteur C Fig 5 soit teint position v Allumez pi ce B Fig 5 dans la position ON I La phase de pr ventilation d marre et apr s 10 secondes environ la com bustion commence aussi Pour obtenir une potentialit maxi male il faut allumer C Fig 5 position ww ALLUMAGE AVEC THERMOSTAT R gler le thermostat ou le dispositif de contr le par exemple une minuterie si connect de facon en permettre le fonc tionnement ATTENTION Le g n rateur peut fonctionner de facon automatique SEULEMENT quand un dispositif de contr le par exemple un thermostat ou une minuterie est connect au g n rateur Pour connecter le dispositif de contr le l appareil consulter le paragraphe SCHEMA ELECTRIQUE Lors de la premi re mise en marche ou apr s la vidange com pl te du circuit du gas oil le flux de gas oil au niveau de l injec teur peut tre insuffisant et causer l intervention du dispositif de s curit de contr le de la flamme voir le paragraphe DISPO SITIFS DE S CURIT
16. ble employ est propre Toutes les 50 heures de fonctionnement il faut D monter la cartouche du filtre en ligne voir NETTOYAGE FILTRE GAS OIL la sortir et la nettoyer Toutes les 200 heures de fonctionnement il faut D monter la cartouche du filtre en ligne voir NETTOYAGE FILTRE DE LA POMPE Toutes les 300 heures de fonctionnement il faut e D monter le br leur et nettoyer l int rieur du conduit du br leur le disque flamme et les lectrodes en r glant si n cessaire la distance voir NETTOYAGE DE ROUTINE DU BR LEUR NETTOYAGE FILTRE GAS OIL D visser le verre en plastique et sortir l l ment filtrant car touche Le nettoyer de facon ad quate avec le k ros ne Remettre l l ment filtrant sa place et visser le verre en plas tique au corps fixe du filtre combustible A Garnitures B Verre en plastique C l ment filtrant D Corps fixe du filtre combustible Figure 10 Filtre en ligne NETTOYAGE FILTRE DE LA POMPE D monter le coffre du br leur F Fig 5 identifier la pompe du br leur O Fig 6 D visser l crou A Fig 11 fixant l l ment filtrant la pompe Extrayez l l ment filtrant C Fig 11 Nettoyez le bien avec du k ros ne Ins rez l l ment filtrant et vissez l crou la pompe G A crou B Electrovan nesiple pour D XL9ER elec y trovanne double l pour XL 9SR C Filtrant D Pom
17. el pump P Condenser Q Motor R Burner tube S Combustion head regulator T Photo resistance U1 Electrovalve 1 flame step XL 9ER SR U2 Electrovalve 2 flame step XL 9SR XL9Heater com Distributor North America Easy Clean Systems 916 638 0828 COMBUSTIBLE WARNING The generator runs ONLY on kerosene or die sel fuel The use of impure combustible can cause Blockage of the combustible filter and nozzle Formation of carbonaceous deposits on the electrodes At low temperatures use non toxic antifreeze THEORY OF OPERATION The ventilation needed for proper combustion is produced by a fan inside the burner The air exits the burner sleeve and mixes with the fuel which is nebulised by a high pressure nozzle The fuel is aspirated from the fuel tank by a rotary pump which forces it at high pressure up to the nozzle for nebulisation OPERATING INSTRUCTIONS WARNING Before putting the generator in function and therefore before connecting it to the electrical system you must check to see if the electrical systems technical characteristics correspond to those on the identification plate of the generator STARTING THE GENERATOR 1 Follow all of the safety information 2 Fill the tank with diesel fuel or kerosene 3 Close the fuel cap 4 Plug the alimentation cord into a grounded wall plug with the same tension as the one written on the generator s identification plate STARTING WITHOUT A THERMO
18. elicately lower the heater off the pallet Dispose of the material used to pack the generator according to the current government regulations in your area Check the machine for eventual damages incurred during transportation if the machine appears damaged immediately inform the store where you purchased it NOOPHRHPHHRWD Figur 1 Packaging ON PACKAGING AND STORING If the generator needs to be placed in storage or if it has suffered major damage in transport or needs to be repaired Check for damage in particular of a nature which could cause loss of fuel In this case empty the tank of the remaining fuel For storage place the generator on the same pallet from which it was unpacked and for return on any suitable EPA branded euro pallet Firmly anchor the generator to the pallet Fig 2 Whenever possible slide the cardboard packing from the top down over the pallet and anchor it firmly using suitable materials Fig 1 Store the machine in a suitable dry place and do not stack more than two Despatch the generator preferably as shown Fig 1 or atleast as shown in Fig 2 S eO CC coeoopoop 900000 000000 8900000 AR 900000 00000 ue gt Figur 2 On pallett XL9Heater com Distributor North America Easy Clean Systems 916 638 0828 SAFETY INFORMATION WARNING IMPORTANT Read this entire man
19. eption faite du r servoir de com bustible incorpor dans le g n rateur 9 Le combustible doit tre conserv dans des locaux dont le sol ne permet pas la p n tration et l gouttement du combustible lui m me sur des flammes sous jacentes qui peuvent provo quer le d part d un feu h La conservation du combustible doit tre r alis e conform ment la r glementation en vigueur Ne jamais utiliser le g n rateur dans des locaux o sont pr sents de l essence des solvants pour peintures ou d autres vapeurs hautement inflammables Pendant l utilisation du g n rateur respecter toutes les ordon nances locales et les r glementations en vigueur Les r chauffeurs utilis s proximit de b ches de tentures ou d autres mat riels de couverture de m me type doivent tre situ s une distance de s curit de ces derniers La distance minimum de s curit est celle recommand e par les r glemen tations en vigueur dans l tat d appartenance II est galement conseill d avoir recours des quipements de couverture ig nifug s De tels mat riels doivent tre fix s de facon s re pour viter qu ils ne prennent feu et qu il y ait des interf rences avec le g n rateur cause du vent Utiliser seulement dans des espaces bien a r s Pr voir une ouverture ou au moins un change d air ad quat selon les r glementations en vigueur dans l tat d appartenance de facon faire p n trer de l air
20. g n rateur Utiliser uniquement du k ros ne ou du gas oil afin d viter les risques d incendie ou d explosion Ne jamais utiliser d essence de mazout de solvants pour peintures d alcool ou d autres combustibles hautement inflammables R approvisionnement a Le personnel charg du ravitaillement doit tre qualifi et familiaris avec les instructions du fabricant et avec la r gle mentation en vigueur relative au r approvisionnement en toute s curit des g n rateurs b Utiliser uniquement le combustible express ment indiqu sur l tiquette d identification du g n rateur c Avant d effecteur le r approvisionnement teindre tous les flammes y compris celle de veille et attendre que le g n ra teur refroidisse d Au cours du r approvisionnement inspecter toutes les conduits du combustible et les raccordements la recherche d ventuelles fuites Toute fuite doit tre r par e avant de remettre en marche le g n rateur e Une quantit de combustible sup rieure celle pour main tenir en fonction le g n rateur pendant une journ e ne doit en aucun cas tre dans le m me b timent et proximit du g n rateur Les citernes de stockage du carburant doivent tre dans une structure s par e f Tous les r servoirs du combustible doivent se trouver une distance minimum de s curit des r chauffeurs chalumeaux oxhydriques quipements pour la soudure et d autres sources inflammables exc
21. ght source does not directly face the front deflector Control the electric system Control the fuel supply lines D Fig 3 Resupply the fuel tank Dismantle and clean or replace it Raise the value or control the Timer settings Replace it Turn off the electric system and then turn off the switches or wait for the power supply to return Control the installation following the descrip tion in the CONNECTING THE CONTROL DEVICE paragraph Replace it Open the burner coffer F Fig 5 and replace it Reestablish the correct value Increase the combustible air Clean or replace the nozzle Drain the fuel from the appropriate drain plug M Fig 4 5 Resupply the tank XL9Heater com Distributor North America Easy Clean Systems 916 638 0828 INDEX 1 PR SENTATION DU PRODUIT D BALLAGE ET EMBALLAGE INFORMATIONS AU SUJET DE LA S CURIT IDENTIFICATION DES PRODUITS COMBUSTIBLE PRINCIPES DE FONCTIONNEMENT MISE EN MARCHE DISPOSITIFS DE S CURIT TRANSPORT ET D PLACEMENT PROGRAMME D ENTRETIEN PR VENTIF ACCESSOIRES REP RAGE DES PANNES PR SENTATION DU PRODUIT XL 9 est un g n rateur de chaleur rayonnement La techno logie rayonnement suit le principe physique qui est la base du r chauffement par la lumi re du soleil En effet le soleil r chauffe les corps sans flux d air chaud mais travers des ondes irradiantes Le syst me rayonnement
22. ion vents When the heater is hot connected to the power supply or in function it should never be moved handled or refilled and no maintenance should be performed on it Smoke that is produced from the first combustion is due to the evaporation of organic materials ceramic present in the com bustion tank and anticorrosion oil present on the surface of the burner After a few minutes the smoke will stop The environmental operating temperature is 22 F 104 F www XL9Heater com Distributor North America Easy Clean Systems 916 638 0828 en PRODUCT IDENTIFICATION A SS Figur 3 Figur 4 A Combustion chamber B Hole for raising generator C Fuel filter or pre heated filter optional D Fuel supply E Fuel Re turn F Fuel tank cap G Foot or wheel optional H Fuel level indicator I Block of the group combustion L Radiant deflector M Fuel drain plug N Fuel tank O Handle to move the genera tor P Hinge block Q Burner R Inclination regulator Figur 6 Components burner A Air vent regulator B Lighted ON OFF button C ON OFF switch depending on power option XL 9SR D RESET But ton E Power indicator F Burner coffer G Thermostat plug H Screw for burner block I Post ventilation device L Flame con trol device M Transformer N1 Pressure regulator XL 9ER of the pump N2 Pressure regulator XL 9SR of the pump Of XL 9ER fuel pump O2 XL 9SR fu
23. istances electrodes nozzle A Burner tube B Screw of the burner tube C Screw of the group diskflame electrodes D Flame disk E Electrodes F Tube G Nozzle H Screw ACCESSORIES THERMOSTAT WARNING Before beginning any maintenance operation you must stop the machine according to the instructions provided in the paragraph TURNING OFF THE GENERA TOR disinsert the electrical supply by unplugging it and waiting for the generator to cool down PRE HEATING FILTER ROTATING WHEEL WITH BRAKES www XL9Heater com Distributor North America Easy Clean Systems 916 638 0828 en 1 FAULTS AND THEIR LIKELY CAUSES WARNING Before beginning any maintenance operation you must stop the machine according to the instructions pro vided in the paragraph TURNING OFF THE GENERATOR disinsert the electrical supply by unplugging it and waiting for the generator to cool down SYMPTOMS POSSIBLE CAUSE SOLUTION The machine stops with flame RESET button D Fig 5 o 6 on The machine stops spray ing fuel without verifying the flame RESET button D Fig 506 on The machine doesn t spray fuel and stops RESET button D Fig 5 o 6 on The burner doesn t start Flame is not well confirmed with an unpleasant odour black smoke or flames com ing out of the anterior deflec tor Photo resistance circuit is broken or the Pho to resistance is dirty with smoke residue Dirty
24. n rateur comme un chariot Au cas o l appareil n a pas de roues pivotantes il convient de bloquer le pivot P Fig 4 plac sur un des montants lat raux du g n rateur Baisser la poign e de la position au repos Fig 8 Tourner la poign e la posi tion position de d placement Fig 9 Soulever le g n rateur et le d placer en le faisant rouler sur les roues ant rieures Ss Figure 9 Position avec poign es ouvertes en d place ment AVERTISSEMENT Avant de d placer l appareil il faut ar r ter la machine selon les indications d crites dans le pa ragraphe EXTINCTION DU G N RATEUR d brancher l alimentation lectrique en tant la fiche de la prise lec trique murale et attendre que le g n rateur refroidisse PROGRAMME D ENTRETIEN PR VENTIF AVERTISSEMENT Avant de commencer une quelconque op ration d entretien arr ter la machine selon les indi cations d crites dans le paragraphe EXTINCTION DU G N RATEUR arr ter l alimentation lectrique en d branchant la fiche de la prise lectrique et attendre que le g n rateur refroidisse Les instructions contenues dans ce paragraphe qui concernent les temps d entretien sont troitement li es au nettoyage du combustible et au type d espace dans lequel le g n rateur est utilis En particulier les indications ci dessous sont valables pour des espaces de travail a r s et peu poussi reux et lorsque le combusti
25. nlever le carton par le haut Enlever les supports qui bloquent le g n rateur sur la palette Fig 2 Faire descendre d licatement le g n rateur de la palette liminer le mat riel utilis pour emballer le g n rateur selon les r glementations en vigueur dans l tat d appartenance e Contr ler la machine de fa on d celer d ventuels dom mages subis durant le transport Si l appareil semble tre abi m informer imm diatement le concessionnaire chez lequel a t effectu e l acquisition NOoOPHPAHPHHRWDND NET Figure 1 Emballage EMBALLAGE Y ENTREPOSAGE Si le g n rateur doit tre stock s il a subi des d g ts lors du transport ou s il doit tre r par vous devez Contr ler que la machine ne soit pas endommag e en particulier qu elle ne pr sente pas de fuite de combustible Si c est le cas vider compl tement le r servoir de son carburant Placer le g n rateur sur la plate forme o il a t d ball stockage ou sur une plate forme adapt e sa restitution europallet marqu EPA Fixer solidement le g n rateur sur la plate forme Fig 2 Lorsque c est possible placer l emballage en carton depuis le haut sur la plate forme en le fixant avec des mat riaux ad hoc Fig 1 Stocker la machine dans un endroit adapt et non humide et ne pas placer plus de deux machines l une sur l autre Exp dier le g n rateur comme sur la Fig 1
26. ou du moins la Fig 2 ES O OOOOOO d OOOOOO 8000000 Da 000000 00000 e9 AID Figure 2 Sur le palette www XL9Heater com Distributor North America Easy Clean Systems 916 638 0828 2 fr INFORMATIONS AU SUJET DE LA S CURIT AVERTISSEMENT IMPORTANT Lire attentivement et compl tement le manuel d instructions avant d allumer ou d entretenir le g n rateur Un mauvais usage du g n rateur peut pro voquer des l sions graves ou fatales la suite de br lures d incendie d explosion de d charges lectriques ou d asphyxie par hydroxyde de carbone DANGER L asphyxie par oxyde de carbone peut tre fatale Asphyxie par oxyde de carbone Les premiers sympt mes de l asphyxie par oxyde de carbone ressemblent ceux de la grippe avec des maux de t te des vertiges et ou des naus es De tels sympt mes pourraient tre caus s pas un fonctionne ment d fectueux du g n rateur Dans ce cas sortir imm dia tement l air libre Faire r parer le g n rateur Certaines per sonnes ressentent davantage les effets de l oxyde de carbone les femmes enceintes ceux qui souffrent de maladies car diaques ou pulmonaires les an miques les alcooliques et ceux qui se trouvent en altitude S assurer de lire et de comprendre tous les avertissements Conserver ce manuel comme future r f rence il fait en effet office de guide pour le fonctionnement s r et correct du
27. pe Figure 11 Pompe du br leur www XL9Heater com Distributor North America Easy Clean Systems 916 638 0828 fr NETTOYAGE DE ROUTINE DU BR LEUR ACCESSOIRES THERMOSTAT D visser la vis H Fig 5 qui bloque le br leur A Fig 3 la chambre de combustion Extraire le br leur de la chambre de combustion Fig 3 D visser les trois vis B Fig 12 qui bloquent le conduit du br leur A Fig 12 D monter le conduit D visser la vis C Fig 13 qui bloque le groupe disque flamme lectrodes et l enlever du porte injecteur F Fig 14 Nettoyer le disque flamme D Fig 14 et les lectrodes E Fig 14 D visser l injecteur G Fig 14 du porte injecteur F Fig 14 Le nettoyer ou si n cessaire le remplacer Remonter l injecteur G Fig 14 sa place Remonter le groupe disque flamme lectrodes en r glant les distances de facon ad quate d apr s l illustration Fig 14 AVERTISSEMENT Avant de commencer une quelconque op ration d entretien arr ter la machine selon les indi cations d crites dans le paragraphe EXTINCTION DU GENERATEUR arr ter l alimentation lectrique en d branchant la fiche de la prise lectrique et attendre que le g n rateur refroidisse FILTRE DE PR CHAUFFAGE E e a 4 mm 22 mm Figure 14 Distances lectrodes injecteur A Conduit du br leur B Vis qui bloquent le condui
28. r les tubes d arriv e du gas oil D Fig 3 Effectuer le ravitaillement Le nettoyer ou le remplacer En augmenter la valeur ou contr ler les temps de la Minuterie La remplacer Fermer l installation lectrique et fermer suc cessivement les interrupteurs ou attendre le retour de la tension Contr ler l installation selon la description du CONNECTUNG DU THERMOSTAT D AMBIANCE La remplacer Ouvrez le coffre du br leur F Fig 5 et rem placez le La remettre la valeur pr vue Augmenter l air pour la combustion Nettoyer l injecteur ou le changer Vidanger le combustible partir du bouchon pr vu cet effet M Fig 4 Effectuer le ravitaillement en combustible www XL9Heater com Distributor North America Easy Clean Systems 916 638 0828 CE CONFORMITY CERTIFICATE DICHIARAZIONE DI CONFORMIT CE EG KONFORMITAT SERKLARUNG DECLARACI N DE CONFORMIDAD CE DECLARATION DE CONFORMITE CE EG CONFORMITEITVERKLARING DECLARACAO DE CONFORMIDADE CE EU OVE RENSSTEMMELSESERKL ERING EY VAATIMUSTENMUKAISUUSVAKUUTUS CE SAMSVAR SERKL RING EG FORSAKRAN OM OVERENSSTAMMELSE DEKLARACJA ZGODNOSCI WE DEKMNAPALIMA O COOTBETCTBMM CE PROHL EN O SHOD CE EK MEGFELEL S GI NYILATKOZAT IZJAVA O SKLADNOSTI IN OZNAKA CE CE UYGUNLUK BEYANI IZJAVA CE O SUKLADNOSTI ES ATITIKTIES DEKLARACIJA EK ATBILSTIBAS DEKLARACIJA E VA STAVUSDEKLARATSIOON DECLARATIE DE CONFORMITAT
29. rencontre un suc c s croissant aupr s de la client le professionnelle en vertu des nombreux avantages qu offre ce type de technologie XL 9 a t congu sur la base de ce principe physique et il est ainsi de venu un g n rateur de chaleur indispensable dans les endroits o l on a besoin d une source de chaleur homog ne et uniforme pour chauffer d congeler et s cher Par ailleurs il est tr s silen cieux et permet donc de travailler avec la machine en marche sans devoir supporter les inconv nients caus s par le bruit des autres syst mes de chauffage Le g n rateur est quip de roues en caoutchouc et peut donc tre facilement transport d une pi ce l autre tout comme il peut tre soulev et plac diff rents niveaux gr ce des anneaux de fixage sp ciaux Son autonomie de performance et la possibilit de l utiliser en automatique gr ce un thermostat offrent l op rateur une grande libert d emploi Un indicateur externe pour le contr le de la quantit de carburant contenue dans le r servoir permet de v rifier rapidement s il faut rajouter ou non du combustible La possibilit d avoir deux degr s de puissance dans la version S permet une utilisation optimale de la machine sous diff rents r gimes d application et toutes les p riodes de l ann e DEBALLAGE ET EMBALLAGE D BALLAGE liminer les supports utiliser pour emballer l appareil Fig 1 Ouvrir l emballage partir du haut E
30. t du br leur C Vis qui bloque D Flame disk E Electrodes F Tube G Nozzel H Vis XL9Heater com Distributor North America Easy Clean Systems 916 638 0828 REP RAGE DES PANNES AVERTISSEMENT Avant de commencer une quelconque op ration d entretien arr ter la machine selon les indications d crites dans le paragraphe EXTINCTION DU GENERATEUR arr ter l alimentation lectrique en d branchant la fiche de la prise lectrique et attendre que le g n rateur refroidisse PANNE OBSERV E CAUSE POSSIBLE SOLUTION L appareil se bloque avec une flamme Bouton RESET D Fig 5 o 6 allum L appareil se bloque et crache du combustible sans flamme Bouton RESET D Fig 5 o 6 allum L appareil ne crache pas de combustible et se bloque Bouton RESET D Fig 5 o 6 allum Br leur bloqu Flamme faible avec une mau vaise odeur une fum e noire et des flammes qui sortent du d flecteur ant rieur Circuit de la Photo r sistance en panne ou Photo r sistance encrass e de fum e Filtre combustible sale Circuit de la carte de contr le de la flamme en panne Disque flamme ou conduit Fig 12 13 14 sales Installation lectrique non conforme Transformateur d allumage M Fig 6 inter rompu Les c bles du transformateur d allumage sont la masse Les lectrodes ne sont pas la bonne dis tance Les lectrodes sont la masse parce qu elles sont s
31. the type of fuel expressly specified on the identification plate located on the generator C Before filling the tank extinguish all of the flames including the pilot light and wait for the generator to cool down d While filling the tank inspect all of the fuel lines and their junctions to check for fuel losses Any losses must be repaired before starting the generator again e Under no circumstances should you conserve a quantity of combustible superior to that which is necessary to maintain in function the heater for one day in the same building or nearby the heater The fuel storage cisterns should be located in a separate building All of the fuel tanks should be located a minimum safety distance from the heater like current government regulation as well as oxyhydrogen blowpipe torches welding equipment and similar ignition sources with the exception of the fuel tank incorporated in the generator g The fuel should be stored in areas where the flooring will not soak up any fuel spills or any drips of fuel line the flame underneath that could cause a fire h All fuel storage must be effectuated in compliance with the current government regulations Never use the generator in rooms where gasoline paint thin ner or other highly flammable materials are located While the heater is in use follow all of the local ordinances and current government regulations I Heaters used close to large pieces of fabric
32. ual carefully before operating or effectuating any maintenance procedures on this generator The misuse of the generator can cause serious of fatal injuries due to burns fires explosions electrical shock or asphyxiation from carbon monoxide DANGER Carbon monoxide asphyxiation can be fatal Carbon Monoxide Asphyxiation The first symptoms of car bon monoxide asphyxiation are similar to that of the flu head aches dizziness and or nausea These symptoms could be caused by the malfunctioning of the generator In this case go outside immediately Have the generator repaired Then you may start it again Some people are more affected by the effects of carbon monoxide than others especially pregnant women those who suffer from heart or lung disease or anaemic people also those who have consumed alcoholic beverages and those who are at high altitudes Be sure to read and understand all of the warnings Conserve this manual for future reference it will provide you with instructions to operate your generator safely and correctly Use only kerosene or diesel to diminish the risk of fire or explo sion Never use gasoline naphtha paint thinners alcohol or other highly flammable combustants Filling the tank a The personnel charged with filling the tank should be qualified and completely familiar with the factory instructions and the current governmental regulations regarding the secure provision of generators b Use only
33. uel 2 Press the Restart button D Fig 5 and 6 If the generator still isn t functioning consult the FAULTS AND THEIR LIKELY CAUSES paragraph to identify the cause WARNING Before the second ignition machine extin guished and adequately cold to assure the blocking of the screws that block the anterior deflector L Fig 4 WARNING The electric power that feeds the generator must be grounded and have a differential magnetic thermal switch The generator s electric cord must be attached to a plug equipped with a section switch TURNING THE GENERATOR OFF Turn the switch B Fig 5 to the OFF position O or turn the ther mostat or control device Timer off if there is one connected The flame will go out and the ventilation will continue until it has finished its post ventilation cycle cooling down WARNING Before unplugging the alimentation cord from the wall wait until the post ventilation cycle is complete ly finished it will take approximately 3 minutes to cool down SAFETY DEVICE The generator is equipped with a safety device L Fig 6 which controls the flame If one or more anomalies occur when the generator is functioning the device will block the burner and the RESET button D Fig 5 or 6 will light up The generator also has a post ventilation device which enables optimal automatic cooling of the combustion chamber for some 3 minutes Before turning the generator on again you must identify
34. vastab Declar m c este conform urm toarelor Prehlasuje sa Ze je v s lade s Aeknapupa ce ye orroBaps Ha BianoBigae BuMoram Izjavljuje se da je u skladu s AnAwvouye OT eivai c pQuvo pE ERNE 2004 108 EEC 2006 95 EEC EN 55014 1 2006 A1 2009 EN 61000 3 2 2006 EN 61000 3 3 2008 EN 55014 2 1997 A1 2001 A2 2008 EN 62233 2008 EN 60335 2 102 2006 EN 60335 1 2002 A11 2004 A1 2004 A12 2006 A2 2006 A1 EC 2007 A13 2008 fe LU Pastrengo 10 10 2012 Stefano Verani CEO MCS Group www XL9Heater com Distributor North America Easy Clean Systems 916 638 0828 MCS Italy S p A Via Tione 12 37010 Pastrengo VR Italy info mcsitaly it MCS Central Europe Sp z 0 0 ul Magazynowa 5A 62 023 Gadki Poland office mcs ce pl MCS China LTD Unit 11 No 198 Changjian Rd Shanghai China office mcs china cn
35. www XL9Heater com Distributor North America Easy Clean Systems 916 638 0828 gt en Infrared Heater X LG Operating manual SYSTEMS gt fr G n rateur de chaleur l infrarouge Manuel d instructions E 4117 410 Edition 12 gt en IMPORTANT Be sure to read and understand this operating manual before assembling the set up and functioning or the maintenance of this heater The misuse of this heater can cause serious injuries Conserve this manual for future reference gt fr IMPORTANT Lire attentivement et comprendre ce manuel avant d effecteur l assemblage la mise en marche ou l entretien du r chauffeur Le mauvais usage de celui ci peut provoquer de graves l sions Conserver ce manuel comme futur objet de r f rence XL 9ER XL 9SR www XL9Heater com Distributor North America Easy Clean Systems 916 638 0828 TECHNICAL DATA DONN ES TECHNIQUES XL 9ER XL 9SR 146900 Btu hr 99300 Btu hr 146900 Btu hr P1 5 Ib hr 7 4 Ib hr P2 7 A Ib hr DIESEL KEROSENE DIESEL KEROSENE 110 120 V 50 60 Hz 1 2A 0 85 GpH 60 Hr DANFOSS 0 60 GpH 60 Hr DANFOSS 145 PSI 260 PSI www XL9Heater com Distributor North America Easy Clean Systems 916 638 0828 INDEX 1 PRODUCT PRESENTATION UNPACKING SAFETY INFORMATION PRODUCT IDENTIFICATION COMBUSTIBLE THEORY OF OPERATION OPERATING INSTRUCTION SAFETY DEVICE MOVING AND TRANSPORTATION PREVENTATIVE MAINTENANCE SCHEDULE

Download Pdf Manuals

image

Related Search

Related Contents

ABMI PHOTO-PLOT INTERPRETATION MANUAL Alberta  Indesit XWA81252X  エンバーパワーライト 取扱説明書  Télécharger(PDF  Manual de Instalación y Programación Telebox  Stabilo® Knöchelstütze  Samsung Galaxy Note (8.0) Kasutusjuhend  XC640C - Emerson Climate Technologies  でんきロードヒーティング  

Copyright © All rights reserved.
Failed to retrieve file