installation instructions instructions d`installation

image

Contents

1. Actual unit may or may not contain doors with windows depending on model Selon le mod le le pr sent appareil n offre peut tre pas de hublot de porte TABLE OF CONTENTS Page Dryer Safety dansante aada aeaaaioii aianei 2 Tools amp Parts RSR ne 5 Dimensions Clearances 6 Location Requirements nn 7 Gas Dryer Electrical Requirements nn 8 Gas Requirements rennes 9 Electric Dryer Electrical Requirements sssssssccsseecsecsseesseessseesse 10 Dryer Venting Requirements rs 13 Gas Supply Connection seen 15 Electric Dryer Electrical Connections ssssssssssseesseesssessseesseessstense 17 L veli gicrsann tate en te 21 Complete Installation nn 22 Reversing Dryer Door Swing mme 23 Maintenance Instructions ne 24 If You Need Assistance ner 24 Electronic Control Setup Instructions x 25 Warranty csecccsisedcssaceucccsadcevsssanivesnstcvescesssssusnscassedesuscuansesnusseaitaissassbiisnensasssstiaiseae 30 W10761035A W10761036A SP MAYTAG COMMERCIAL LAUNDRY INSTALLATION INSTRUCTIONS Commercial Stacked Dryer Gas 120 Volt 60 Hz or Electric 120 240 Volt 60 Hz INSTRUCTIONS D INSTALLATION S cheuse usage commercial superpos e gaz 120 Volts 60 Hz ou lectrique 120 240 Volts 60 H2 TABLE DES MATI RES Page S curit de la SECHCUSEC cccsssssssccssescssessseesseesssessseesseessseesseesseesseesaessaes 31 Qu tils
2. 1 Retirer le capuchon rouge de la canalisation de gaz 2 Raccorder la canalisation de gaz la s cheuse Utiliser un compos d tanch it compatible avec le gaz propane Si un conduit m tallique flexible est utilis v rifier qu il n est pas d form Si n cessaire pour une intervention d entretien ou de r paration ouvrir le panneau de plinthe Utiliser un couteau mastic pour appuyer sur le verrou du panneau de plinthe situ dans les coins sup rieurs du panneau de plinthe Tirer le panneau de plinthe vers le bas pour l ouvrir Le panneau de plinthe est fix la partie inf rieure 42 3 Ouvrir le robinet d arr t de la canalisation d arriv e de gaz et v rifier que la canalisation de gaz la s cheuse est ouverte 4 V rifier tous les raccordements en les badigeonnant d une solution de d tection des fuites non corrosive approuv e L apparition de bulles indique une fuite R parer toute fuite ventuelle RACCORDEMENT LA CANALISATION DE GAZ Type de gaz Cette s cheuse est quip e pour une alimentation au gaz naturel Sa conception est homologu e par CSA International pour l alimentation au gaz de p trole liqu fi propane ou butane avec conversion appropri e Ne pas entreprendre de convertir la s cheuse pour une utilisation avec un gaz diff rent de celui indiqu Canalisation d alimentation en gaz M thode recommand e Installer une canalisation de gaz rigide de 1 2 13 mm
3. Cette s cheuse ne doit pas tre install e dans un placard muni d une porte Il vous faudra E Une prise lectrique reli e la terre situ e moins de 6 pi 1 8 m de la prise du cordon lectrique se trouvant l arri re de la s cheuse Voir Sp cifications lectriques M Un plancher de niveau ayant une pente maximale de 1 25 mm sous l ensemble de la s cheuse L installation de la s cheuse sur des surfaces de sol molles telles que tapis ou surfaces avec sous couche en mousse n est pas recommand e 36 Distances de d gagement pour l installation pour la s cheuse E L emplacement doit tre assez grand pour permettre d ouvrir compl tement la porte de la s cheuse E Pr voir davantage d espace pour faciliter l installation et l entretien La porte s ouvre plus de 180 m Un espace suppl mentaire peut tre requis pour les moulures de porte et de plancher et pour les plinthes M Un espace suppl mentaire de 1 25 mm de tous les c t s de la s cheuse est recommand pour r duire le transfert du bruit Lors de l installation d une s cheuse gaz IMPORTANT Observer les dispositions de tous les codes et r glements en vigueur M V rifier les exigences des codes Certains codes limitent ou n autorisent pas l installation d une s cheuse dans un garage un placard ou une chambre coucher Communiquer avec l inspecteur en b timents local m S assurer que les rebords inf rieur
4. 43 NIVELLEMENT Le nivellement de la s cheuse permet le bruit et les vibrations 3 Si la s cheuse n est pas d aplomb utiliser une cl plate ou une excessifs cl molette de 1 ou 25 mm pour tourner les contre crous dans le sens horaire vue du dessus sur les pieds jusqu ce A AVERTISSEMENT qu ils se trouvent environ 1 2 13 mm de la caisse de la s cheuse Tourner ensuite le pied de nivellement dans le sens antihoraire pour abaisser la s cheuse ou dans le sens horaire pour les soulever Contr ler nouveau l aplomb de la s cheuse Risque du poids excessif Utiliser deux ou plus de personnes pour d placer et et v rifier que les quatre pieds sont en contact ferme avec le sol installer la s cheuse R p ter si n cessaire Le non respect de cette instruction peut causer CONSEIL UTILE Il serait judicieux de soulever l avant de un bless re ados ou dautire blessure la s cheuse d environ 4 102 mm l aide d une cale en bois ou d un objet similaire qui soutiendra le poids de la s cheuse 1 Enlever la plaque de carton plac sous la s cheuse Placer un lea niveau sur les bords sup rieurs de la s cheuse en contr lant chaque c t et l avant Si elle n est pas d aplomb faire basculer la s cheuse et r gler les pieds vers le haut ou vers le bas tel qu indiqu dans les tapes 3 et 4 et recommencer si n cessaire Contre z crous 4 Apr s que l aplomb de la s cheuse a t tabli et que les
5. 8 Reattach screws at top bottom and side of door 5 screws 9 Attach door hinges to dryer door so that larger hole is at the 3 Lift door until top screws in cabinet are in large part of hinge bottom of the hinge and the hinge pin is toward the door front slot Pull forward off screws Set door handle side up on top of towel Remove top screws from cabinet 4 Remove screws attaching hinges to door 5 Remove screws at top bottom and side of door 5 screws 10 Remove the 4 screws that attach 2 plugs on the left side Attach plugs to right side using the same 4 screws 11 Insert screws into bottom holes on left side of cabinet Tighten 6 Holding door over towel grasp sides of outer door and gently screws halfway Position door so large end of door hinge slot lift to separate it from inner door Do not use a putty knife to pry is over screws Slide door up so screws are in bottom of slots apart Do not pull on door seal or plastic door catch Tighten screws Insert and tighten top screws in hinges re fe 12 Close door and check that door strike aligns with door catch If needed slide door catch left or right within slot to adjust alignment 23 MAINTENANCE INSTRUCTIONS E Clean lint screen before and after each cycle If dryer does not operate check the following m Removing accumulated lint a From inside the dryer cabinet a Lint should be removed every
6. The supply line must be equipped with a manual shut off valve installed within 6 ft 1 8 m of dryer in accordance with National Fuel Gas Code ANSI Z223 1 This valve should be located in same room as dryer It should be in a location that allows ease of opening and closing Do not block access to shut off valve In Canada an individual manual shut off valve must be installed in accordance with the B149 installation codes CAN CGA B149 1 and CAN CGA B149 2 16 Flexible Metal Appliance Connector It is recommended that a new flexible stainless steel gas line design certified by CSA International be used for connecting the dryer to the gas supply line The gas pipe which extends through the lower rear of the dryer is provided with 3 8 male pipe thread NOTE Do not kink or damage the flexible stainless steel gas line when moving the dryer Rigid Pipe Connection The rigid pipe connection requires a combination of pipe fittings to obtain an in line connection to the dryer t TEFLON is a registered trademark of E l Du Pont De Nemours and Company ELECTRIC DRYER ELECTRICAL CONNECTIONS U S A ONLY Strain Relief Remove Terminal Block Cover i K A SS WKY ar Power Supply Cord Strain Relief 1 Insert strain relief Direct Wire Strain Relief 1 Insert strain relief nee G
7. 6 pi 1 8 m maximum de la s cheuse conform ment au National Fuel Gas Code ANSI Z228 1 Le robinet doit se trouver dans la m me pi ce que la s cheuse La canalisation doit se trouver en un endroit facilement accessible pour les man uvres d ouverture fermeture Ne pas entraver l acc s au robinet d arr t manuel Au Canada un robinet d arr t individuel doit tre install conform ment aux codes d installation B149 CAN CGA B149 1 et CAN CGA B149 2 sur la plaque signal tique sans consulter le fournisseur de gaz au pr alable L op ration de conversion doit tre ex cut e par un technicien de r paration qualifi Les num ros de pi ce de l ensemble de conversion de gaz sont indiqu s sur la base des br leurs Raccord m tallique flexible pour appareil m nager Il est recommand d utiliser une canalisation en acier inoxydable souple neuve conception homologu e par CSA International pour raccorder la s cheuse la conduite d alimentation en gaz La canalisation d arriv e de gaz mergeant au niveau de la partie inf rieure arri re de la s cheuse est dot e d un filetage m le de 3 8 REMARQUE Ne pas d former endommager la canalisation en acier inoxydable flexible lors du d placement de la porte Raccordement par conduit rigide On doit utiliser un ensemble de raccords pour r aliser un raccordement rigide la s cheuse t TEFLON est une marque d pos e de E I Du Pont De Nemours et Compagnie
8. la terre En cas de mauvais fonctionnement ou de panne la liaison la terre r duira le risque de choc lectrique en offrant au courant lectrique un acheminement d vacuation de moindre r sistance Cette s cheuse est aliment e par un cordon lectrique comportant un conducteur reli la terre et une fiche de branchement munie d une broche de liaison la terre La fiche doit tre branch e sur une prise appropri e qui est bien install e et reli e la terre conform ment tous les codes et r glements locaux Pour une s cheuse raccord e en permanence Cette s cheuse doit tre raccord e un syst me de c blage permanent en m tal reli la terre ou un conducteur reli la terre doit tre en fonction avec les conducteurs de circuit et raccord la borne de liaison la terre ou la borne sur la s cheuse AVERTISSEMENT Le raccordement incorrect de cet appareil au conducteur de liaison la terre peut susciter un risque de choc lectrique En cas de doute quant la qualit de liaison la terre de la s cheuse consulter un lectricien ou un technicien ou un personnel qualifi Ne pas modifier la fiche de branchement fournie avec la s cheuse si la fiche ne correspond pas la configuration de la prise de courant demander un lectricien qualifi d installer une prise de courant appropri e CONSERVEZ CES INSTRUCTIONS 37 EXIGENCES DE GAZ Alimentation en gaz AVERTIS
9. OFF or SELECTED ON When selected money held in escrow for 30 minutes without further escrow or cycle activity will be cleared Not Selected OFF Selected ON E Press the DELICATES button once to change this selection E Press the PERM PRESS button once to advance to next code END of SET UP PROCEDURES EXIT FROM SET UP MODE Stacked Models Turn access panel key back to original position DIAGNOSTIC GUIDE If the set up mode is entered and one of the following has occurred the appropriate diagnostic code will be in the display STACKED DRYERS CODE EXPLANATION d1 F 01 Invalid dryer door circuit state Sahara control does not differentiate between invalid state and open door state d4 F 01 CCU error Sahara control will send this error when the motor feedback circuit is sensing voltage with the door open or when the motor should not be on The control does not know if the relay is bad stuck on the relay drive circuit is bad shorted causing the motor relay to stay on or the relay fedback circuit is bad d12 F 01 Coin 2 Failure d13 Upper dryer motor sense circuit error on control board or due to power line interference upper dryer cycles and upper dryer display disabled until diagnostic code is manually cleared Gen 2 Debit Card d17 Lower dryer door sense error on control board or due to power line interference lower dryer cycles and lower dryer display disabled until diagno
10. Select the cycle Using a full heat cycle not the air cycle let the dryer run for at least five minutes Dryer will stop when time is used up NOTE Dryer door must be closed for dryer to operate When door is open dryer stops but timer continues to run To restart dryer close door and re select the cycle 7 Open the dryer door Check that the inside of the dryer is warm If the burner does not ignite and you can feel no heat inside the dryer shut off dryer for five minutes Check that all supply valve controls are in ON position and that the electrical cord is plugged in Repeat five minute test 8 If drying time is too long make sure that the lint screen is clean and that there are no obstructions to airflow in the dryer vent system 9 Restart the dryer and allow it to complete a full heat cycle not air cycle to make sure it is working properly REVERSING DRYER DOOR SWING OPTIONAL You can change your door swing from a right side opening to left side opening if desired 7 Be certain to keep cardboard spacer centered between doors Reattach outer door panel to inner door panel so handle is on Remove the Door Assembly the side where hinges were just removed 1 Place a towel or soft cloth on top of work space to avoid scratching of the surface 2 Open dryer door Remove button screws from cabinet side of hinges Loosen do not remove top screws from cabinet side of hinges Door catch Plugs
11. apr s coupure d lectricit Quelques secondes apr s le r tablissement de l alimentation si un programme tait en cours au moment de la coupure RESELECT CYCLE res lectionner programme clignote sur l affichage indiquant qu il faut appuyer sur un bouton pour red marrer la s cheuse TARIFS Une fois la porte ouverte puis ferm e apr s la fin de programme l affichage indique le prix du programme moins d un r glage pour un fonctionnement gratuit Apr s l insertion de pi ces ou un d bit de la carte de d bit l affichage change pour guider l utilisateur dans le lancement d un programme Il existe quatre 4 types de tarif de la s cheuse Tarif de vente fixe Un param trage de la s cheuse pour un fonctionnement en programme fixe peut accepter uniquement les dur es suppl mentaires accumul es par paliers gaux la dur e d un programme de s chage complet Un maximum de 99 minutes peut tre achet aucun cr dit suppl mentaire n est accord pour les pi ces ins r es lorsque 99 minutes est affich 48 Tarif par accumulation Si le prix est fix une pi ce 1 le mode Accumulateur est en vigueur on doit galement s lectionner Programme fixe avec l option Top Off addition de temps Le temps d utilisation peut tre achet raison d une pi ce la fois jusqu un maximum de 99 minutes Au mode tarification Accumulateur tout l argent introduit est port au cr dit d un programme
12. glable de 0 39 voir VALEUR DE LA PI CE 1 b 05 E Avancer de 0 39 en appuyant sur le bouton WHITES AND COLORS blancs et couleurs Valeur par d faut d finie en usine sur 6 pi ces de 0 25 1 50 E Appuyer une fois sur le bouton PERM PRESS presse permanente pour passer au code suivant DUR E DU S CHAGE SP CIAL Repr sente le nombre de minutes par pi ce de 0 25 pi ce 1 E Le r glage par d faut en usine est de 5 minutes par pi ce Par exemple 6 pi ces de 0 25 x 5 minutes 30 minutes E En appuyant sur le bouton WHITES AND COLORS blancs et couleurs r gler la valeur entre 1 et 99 minutes E Appuyer une fois sur le bouton PERM PRESS presse permanente pour passer au code suivant MINUTES DE L HORLOGE Param trage des minutes de l horloge choisir une valeur entre O et 59 minutes en appuyant sur le bouton WHITES AND COLORS blancs et couleurs E Appuyer une fois sur le bouton PERM PRESS presse permanente pour passer au code suivant HEURES DE LHORLOGE REMARQUE Utilise le format sur 24 heures Param trage des heures de l horloge choisir une valeur entre O et 23 heures en appuyant sur le bouton WHITES AND COLORS blancs et couleurs E Appuyer une fois sur le bouton PERM PRESS presse permanente pour passer au code suivant HEURE DE DEBUT DU TARIF SPECIAL REMARQUE Utilise le format sur 24 heures Repr sente l heure de d but entre O et 23 heures E S lectionner
13. quatre pieds sont en contact ferme avec le sol tourner les contre crous dans le sens antihoraire vue du dessus sur les pieds de nivellement l aide d une cl plate ou d une cl molette de 1 ou 25 mm jusqu ce qu ils soient bien serr s contre la caisse de la s cheuse CONSEIL UTILE On devra peut tre de nouveau soulever l g rement la s cheuse l aide d une cale de bois Pas d aplomb D APLOMB Pas d aplomb 2 Saisir la s cheuse par le dessus et la faire basculer d avant en arri re tout en s assurant que les quatre pieds sont en contact ferme avec le sol Faire de nouveau basculer la s cheuse transversalement Si la s cheuse bascule passer l tape 3 et ajuster les pieds de nivellement Si les quatre pieds sont en contact ferme avec le sol passer l tape 4 ACHEVER L INSTALLATION 1 Consulter les sp cifications lectriques V rifier que la tension 6 Contr ler le bon fonctionnement de la s cheuse Fermer la porte lectrique disponible est correcte et que la prise de courant de la s cheuse S lectionner un programme Faire fonctionner est convenablement reli e la terre Voir Sp cifications la s cheuse pendant au moins cinq minutes programme de lectriques s chage avec chaleur pas le programme de s chage l air La s cheuse s arr tera l expiration de la p riode ainsi 2 V rifier que toutes les pi ces sont maintenant install es de S il
14. room or location needed in order to make the commercial appliance operate correctly 10 Factory specified replacement parts on commercial appliances with original model serial numbers that have been removed altered or cannot be easily determined 11 Discoloration rust or oxidation of stainless steel surfaces 12 Factory specified replacement parts as a result of incorrect diagnosis or repair by an out of network service company The cost of repair or replacement under these excluded circumstances shall be borne by the customer DISCLAIMER OF IMPLIED WARRANTIES IMPLIED WARRANTIES INCLUDING ANY IMPLIED WARRANTY OF MERCHANTABILITY OR IMPLIED WARRANTY OF FITNESS FOR A PARTICULAR PURPOSE ARE LIMITED TO ONE YEAR OR THE SHORTEST PERIOD ALLOWED BY LAW Some states and provinces do not allow limitations on the duration of implied warranties of merchantability or fitness so this limitation may not apply to you This warranty gives you specific legal rights and you also may have other rights that vary from state to state or province to province DISCLAIMER OF REPRESENTATIONS OUTSIDE OF WARRANTY Maytag makes no representations about the quality durability or need for service or repair of this commercial appliance other than the representations contained in this Warranty If you want a longer or more comprehensive warranty than the limited warranty that comes with this commercial appliance you should ask Maytag or your retailer about buying
15. single phase 120 240 volt 60 Hz AC only electrical supply or 3 or 4 wire 120 208 volt electrical supply if specified on the serial rating plate on a separate 30 amp circuit fused on both sides of the line A time delay fuse or circuit breaker is recommended Connect to an individual branch circuit Do not have a fuse in the neutral or grounding circuit E Do not use an extension cord E f codes permit and a separate ground wire is used it is recommended that a qualified electrician determine that the ground path is adequate Electrical Connection To properly install your dryer you must determine the type of electrical connection you will be using and follow the instructions provided for it here E This dryer is manufactured ready to install with a 3 wire electrical supply connection The neutral ground conductor is permanently connected to the neutral conductor white wire within the dryer If the dryer is installed with a 4 wire electrical supply connection the neutral ground conductor must be removed from the external ground connector green screw and secured under the neutral terminal center or white wire of the terminal block When the neutral ground conductor is secured under the neutral terminal center or white wire of the terminal block the dryer cabinet is isolated from the neutral conductor E If local codes do not permit the connection of a neutral ground wire to the neutral wire see Optional 3 wire c
16. 2 years or more often depending Oo on dryer usage Cleaning should be done by a qualified person P E From the exhaust vent Lint should be removed every 2 years or more often depending on dryer usage E Keep area around dryer clear and free from combustible materials gasoline and other flammable vapors and liquids E Keep dryer area clear and free from items that would obstruct the flow of combustion and ventilation air IF YOU NEED ASSISTANCE Electrical supply is connected Circuit breaker is not tripped or house fuse is not blown Door is closed Controls are set in a running or on position Cycle has been selected For gas dryers check that gas supply shut off valves are set in open position Contact your authorized Commercial Laundry distributor To locate your authorized Commercial Laundry distributor or for web inquiries visit www MaytagCommercialLaundry com If you cannot locate your distributor the Commercial Laundry Support Center will answer any questions about operating or maintaining your dryer not covered in the Installation Instructions Just dial 1 800 NO BELTS 1 800 662 3587 the call is toll free When you call you will need the dryer model number and serial number Both numbers can be found on the serial rating plate located in the dryer door opening 24 ELECTRONIC CONTROL SETUP INSTRUCTIONS IMPORTANT Electrostatic Discharge ESD Sensitive Electronics
17. 5 127 mm Cut 12 38 mm from 3 remaining wires Strip insulation back 1 25 mm Shape ends of wires into a hook shape 2 Connect neutral wire to center terminal block PES Connecting Ground and Neutral Wires 1 Remove center terminal block screw and the ground wire by removing the external ground connector screw 19 ELECTRIC DRYER ELECTRICAL CONNECTIONS Connecting 4 Wire Connection Direct Wire Connecting Ground and Neutral Wires cont Connecting Remaining Wires 2 Connect ground and neutral wire to center terminal block 4 Connect remaining wires to outer terminal block Connecting Direct Wire Ground 3 Connect ground wire green or bare with external ground connector screw Connecting 3 Wire Connection Direct Wire Use where local codes permit connecting cabinet ground 2 Connect neutral wire to center terminal block conductor to neutral wire Direct wire cable must have 5 ft 1 52 m of extra length so dryer can be moved if needed Strip 314 89 mm of outer covering from end of cable Strip insulation back 1 25 mm If using 3 wire cable with ground wire cut bare wire even with outer covering Shape ends of wires into a hook shape Connecting Neutral Wire 1 Loosen or remove center terminal block screw 20 ELECTRIC DRYER ELECTRICAL CONNECTIONS Connecting 3 Wire Connection Optional Use for direct wire or power suppl
18. ELECTRIC DRYER ELECTRICAL CONNECTIONS Connection Options Power Cord 4 wire receptacle NEMA Type 14 30R 3 wire receptacle NEMA Type 10 30R Connecting 4 Wire Connection Power Supply Cord IMPORTANT A 4 wire connection is required where local codes do not permit the use of 3 wire connections Standard Power Supply Cord Connectors BO Flanged spade connector Ring Connector Connecting Ground and Neutral Wires 1 Remove center terminal block screw and the ground wire by removing the external ground connector screw 18 Direct Wire 4 4 wire direct gsm 3 wire direct Connecting Power Cord Ground Wire 3 Connect ground wire green or bare with external ground connector screw Connecting Remaining Wires 4 Connect remaining wires with outer terminal block screws o gt ae ca a ELECTRIC DRYER ELECTRICAL CONNECTIONS Connecting 3 Wire Connection Power Supply Cord Standard Power Cord Connectors CS Flanged spade connector Q_ Ys Ring Connector Connecting Neutral Wire 1 Loosen or remove center terminal block screw Connecting 4 Wire Connection Direct Wire IMPORTANT A 4 wire connection is required where local codes do not permit the use of 3 wire connections Direct wire cable must have 5 ft 1 52 m of extra length so dryer can be moved if needed Strip 5 127 mm of outer covering from end of cable leaving bare ground wire at
19. Electrical Code CSA C22 1 If codes permit and a separate ground wire is used it is recommended that a qualified electrical installer determine that the ground path is adequate A copy of the above code standards can be obtained from National Fire Protection Association One Batterymarch Park Quincy MA 02269 CSA International 8501 East Pleasant Valley Road Cleveland Ohio 44131 5575 E Do not ground to a gas pipe E Do not have a fuse in the neutral or ground circuit m A120 volt 60 Hz AC only 15 or 20 amp fused electrical circuit is required A time delay fuse or circuit breaker is also recommended It is recommended that a separate circuit serving only this dryer be provided E If codes permit and a separate ground wire is used it is recommended that a qualified electrician determine that the ground path is adequate m Check with a qualified electrician if you are not sure the dryer is properly grounded Gas Dryer Grounding GROUNDING INSTRUCTIONS E For a grounded cord connected dryer This dryer must be grounded In the event of malfunction or breakdown grounding will reduce the risk of electric shock by providing a path of least resistance for electric current This dryer uses a cord having an equipment grounding conductor and a grounding plug The plug must be plugged into an appropriate outlet that is properly installed and grounded in accordance with all local codes and ordinances E For a permanently connected
20. START HOUR NOTE Uses military time or 24 hr clock This is the start hour 0 23 hours E Select START HOUR by pressing the WHITES AND COLORS button E Press the PERM PRESS button once to advance to next code SPECIAL PRICE STOP HOUR NOTE Uses military time or 24 hr clock This is the stop hour 0 23 hours E Select STOP HOUR by pressing the WHITES AND COLORS button E Press the PERM PRESS button once to advance to next code SPECIAL PRICE DAY This represents the day of the week and whether special pricing is selected for that day A number followed by 0 indicates no selection that particular day 9 10 A number followed by an S indicates selected for that day 9 1S Days of the week 1 7 are selected by pressing the WHITES AND COLORS button Press the DELICATES button once to select special pricing for each day chosen When exiting set up code 9 the display must show the current g p play day of week DISPLAY DAY OF WEEK CODE selected 10 Day 1 Sunday 1S 20 Day 2 Monday 2S 30 Day 3 Tuesday 3S 40 Day 4 Wednesday 4S 50 Day 5 Thursday 5S 60 Day 6 Friday 6S 70 Day 7 Saturday 7S A 00 A 00 A SC 28 E Press the PERM PRESS button once to advance to next code VAULT VIEWING OPTION This option is either NOT SELECTED OFF or SELECTED ON Not Selected OFF Selected ON E Press the DELICATES button once to change this selection When selected
21. an extended warranty LIMITATION OF REMEDIES EXCLUSION OF INCIDENTAL AND CONSEQUENTIAL DAMAGES YOUR SOLE AND EXCLUSIVE REMEDY UNDER THIS LIMITED WARRANTY SHALL BE PRODUCT REPAIR AS PROVIDED HEREIN MAYTAG SHALL NOT BE LIABLE FOR INCIDENTAL OR CONSEQUENTIAL DAMAGES Some states and provinces do not allow the exclusion or limitation of incidental or consequential damages so these limitations and exclusions may not apply to you This warranty gives you specific legal rights and you also may have other rights that vary from state to state or province to province If you need service please contact your authorized Maytag Commercial Laundry distributor To locate your authorized Maytag Commercial Laundry distributor call 1 800 662 3587 or for web inquiries visit www MaytagCommercialLaundry com 02 14 For written correspondence Maytag Commercial Laundry Service Department 2000 NM 63 30 Benton Harbor Michigan 49022 2632 USA S CURIT DE LA S CHEUSE Votre s curit et celle des autres est tr s importante Nous donnons de nombreux messages de s curit importants dans ce manuel et sur votre appareil m nager Assurez vous de toujours lire tous les messages de s curit et de vous y conformer Voici le symbole d alerte de s curit Ce symbole d alerte de s curit vous signale les dangers potentiels de d c s et de blessures graves vous et d autres Tous les messages de s curit suivront le symbole d alerte de
22. article l int rieur de la cuve de la s cheuse lorsque le tambour est en mouvement Ne pas ouvrir le couvercle lorsque la s cheuse est en marche Il s arr tera Ne pas installer ou remiser cette s cheuse un endroit o il serait expos e l eau et ou aux intemp ries Ne pas modifier les organes de commande Nettoyer le filtre charpie avant et apr s chaque charge Ne pas utiliser cette s cheuse si le filtre peluches n est pas install Ne pas r parer ou remplacer un composant quelconque de la s cheuse ni entreprendre une op ration de service si ce n est sp cifiquement recommand dans ce manuel ou dans un manuel d instructions de r parations destin l utilisateur il est alors essentiel que la personne concern e comprenne ces instructions et soit comp tente pour les ex cuter Ne pas utiliser un produit assouplissant de tissu ou des produits pour liminer la statique a moins qu ils ne soient recommand s par le fabricant du produit assouplissant de tissu ou du produit Ne pas utiliser la chaleur pour faire s cher des articles fabriqu s avec du caoutchouc mousse ou de mat riaux semblables La derni re partie d un programme de s chage par culbutage a lieu sans chaleur programme de refroidissement pour faire en sorte que les articles soient laiss s une temp rature qui garantit que les articles ne seront pas endommag s AVERTISSEMENT Ne jamais arr ter le s chage par culbuta
23. as viewed from above on legs until they are about 1 2 13 mm from the dryer cabinet Then turn the leveling leg counterclockwise to lower the dryer or clockwise to raise the dryer Recheck levelness of dryer and that all four legs are firmly in contact with the floor Repeat as needed COMPLETE INSTALLATION HELPFUL TIP You may want to prop up front of dryer about 4 102 mm with a wood block or similar object that will support weight of dryer 4 When dryer is level and all four legs are firmly in contact with the floor use a 1 or 25 mm open end or adjustable wrench to turn jam nuts counterclockwise as viewed from above on leveling legs tightly against dryer cabinet HELPFUL TIP You may want to prop dryer with wooden block 1 Check the electrical requirements Be sure that you have the correct electrical supply and the recommended grounding method See Electrical Requirements 2 Check that all parts are now installed If there is an extra part go back through the steps 3 Check that you have all of your tools 4 Dispose of recycle all packaging materials AWARNING y Electrical Shock Hazard Plug into a grounded 3 prong outlet Do not remove ground prong Do not use an adapter Do not use an extension cord Failure to follow these instructions can result in death fire or electrical shock 5 Plug into a grounded outlet or connect power 22 6 Check dryer operation Close dryer door
24. button once to advance to next code If cycle counter 9 OC is selected the following is true 200 25 1 00 Cycles in HUNDREDS 1 2 00 Cycles in ONES 2 CAS TOTAL CYCLES 225 This is VIEW ONLY and cannot be cleared E Press the PERM PRESS button once to advance to next code ELECTRONIC CONTROL SETUP INSTRUCTIONS OPTIONS 3 XX 9 XX TO USE IF SPECIAL PRICING IS SELECTED Code Explanation 1 00 MONEY COUNTER OPTION This option is either NOT SELECTED OFF or SELECTED ON 00 Not Selected OFF OC Selected ON E Press the DELICATES button 3 consecutive times to select ON and 3 consecutive times to remove Not Selected OFF Counter resets by going from OFF to ON 1 CO Selected ON and not able to be deselected E To select ON and not able to be deselected first select ON then within 2 seconds press the DELICATES button twice the WHITES AND COLORS button once and exit set up mode E Press the PERM PRESS button once to advance to next code 2 00 SPECIAL PRICING OPTIONS This option is either NOT SELECTED OFF or SELECTED ON i 2 00 Not Selected OFF and next available code will be A 00 2 SP Selected ON E Press the DELICATES button once to change this selection If SPECIAL PRICING OPTION is selected there is access to codes 3 XX through 9 XX E Press the PERM PRESS button once to advance to next code If mon
25. dans votre cas Cette garantie vous conf re des droits juridiques sp cifiques et vous pouvez galement jouir d autres droits qui peuvent varier d une juridiction l autre EXONERATION DE RESPONSABILITE EN DEHORS DE LA GARANTIE Maytag ne prend aucun engagement quant la qualit ou la durabilit de l appareil ou en cas de d pannage ou de r paration n cessaire sur cet appareil m nager usage commercial autre que les engagements nonc s dans la pr sente garantie Si vous souhaitez une garantie prolong e ou plus compl te que la garantie limit e fournie avec cet appareil m nager usage commercial renseignez vous aupr s de Maytag ou de votre d taillant propos de l achat d une extension de garantie LIMITATION DES RECOURS EXCLUSION DES DOMMAGES FORTUITS O INDIRECTS LE SEUL ET EXCLUSIF RECOURS DU CLIENT DANS LE CADRE DE LA PRESENTE GARANTIE LIMIT E CONSISTE EN LA R PARATION PREVUE CI DESSUS MAYTAG N ASSUME AUCUNE RESPONSABILITE POUR LES DOMMAGES FORTUITS OU INDIRECTS Certains Etats et certaines provinces ne permettent pas l exclusion ou la limitation des dommages fortuits ou indirects de sorte que ces limitations et exclusions peuvent ne pas tre applicables dans votre cas Cette garantie vous conf re des droits juridiques sp cifiques et vous pouvez galement jouir d autres droits qui peuvent varier d une juridiction l autre Si vous avez besoin de service veuillez contacter votre distributeur autoris de Maytag C
26. de courant lectrique gt Ouvrir la console d brancher le connecteur AA1 refermer la console gt Brancher la s cheuse ou reconnecter la source de courant lectrique E Ins rer et faire tourner dans le sens antihoraire la cl du panneau de l ouverture d acc s Si aucune carte de configuration manuelle n est disponible faire tourner la cl du panneau de l ouverture d acc s pour acc der au mode de configuration manuelle La s cheuse est maintenant au mode de configuration param trage REMARQUE Cette s cheuse est pr r gl e en usine et ne n cessite aucune programmation Toutefois pour modifier les param tres suivre le guide Codes de param trage droite E Ces mod les sont pr configur s en usine avec prix de programme fixe avec appoint Code de param trage E Le bouton PERM PRESS presse permanente permet de progresser d un code au suivant E Le bouton WHITES AND COLORS blancs et couleurs change la valeur du code E Le bouton DELICATES articles d licats s lectionne les options ou les annule NOTE Sur tous les mod les de s cheuses superpos es les s lections effectu es en terme deprogrammation s appliquent aux deux s cheuses Dans le cas de s cheuses superpos es il faut appuyer sur les touches de la SECHEUSE INFERIEURE pour effectuer les s lections Le caract re ou les deux caract res situ s le plus gauche correspondent au code deconfiguration Les deux ou l
27. et pisces sosia i a 34 Dimensions Distances de d gagement cssssssssssssseesssessecseeese 35 Exigences de l emplacement 36 Exigences lectriques pour la s cheuse gaz 37 Exigences d ga2z nnnintnnontrnrnaenenntines 38 Exigences lectriques pour la s cheuse lectrique 39 Exigences concernant l vacuation de la s cheuse usses 40 Raccordement la canalisation de gaz ssescssssssessssesseesneessesseesses 42 Nivellement sissesesssccssicsscesnicsudnsascsostcacssonsennasracsivishoonescanncasscabitaciveassunmatecssseictsaaed 44 Achever l installation nine 45 Inversion du sens d ouverture de la porte ssessssssssessseessseeneessees 46 Instructions d entretien ann 47 Si vous avez besoin d assistance mms 47 Instructions de r glage du tableau de commande lectronique memes 48 Garanties en nanas 55 www maytagcommerciallaundry com DRYER SAFETY Your safety and the safety of others are very important We have provided many important safety messages in this manual and on your appliance Always read and obey all safety messages This is the safety alert symbol This symbol alerts you to potential hazards that can kill or hurt you and others All safety messages will follow the safety alert symbol and either the word DANGER or WARNING These words mean You can be killed or seriously injured if you don t immediately A DANGER follow instructions You can be killed or seriously in
28. et r glements en vigueur Voir Instructions d installation dans un encastrement dans les sections Exigences de l emplacement ll est pr f rable d utiliser une sortie de hotte de 4 102 mm Cependant on peut utiliser un clapet d vacuation de 212 64 mm Une sortie de 2 2 64 mm cause davantage de contre pression que les autres types d installation Pour une installation permanente un syst me d vacuation fixe est requis Raccordement du conduit d vacuation 1 Si on utilise le conduit d vacuation existant s assurer qu il est propre 2 l aide d une bride de fixation de 4 102 mm relier le conduit d vacuation la bouche d vacuation de la s cheuse Beat LA REMARQUE Ne pas enlever le raccord de sortie Le clapet de d charge doit se trouver au moins 12 305 mm au dessus du sol ou de tout autre objet susceptible de se trouver sur le trajet de l air humide rejet par exemple fleurs roches buissons ou neige 12 min 16805 mm 3 Serrer la bride de serrage de tuyau avec un tournevis Phillips 4 S assurer que le conduit d vacuation est fix au clapet d vacuation l aide d une bride de fixation de 4 102 mm 5 Placer la s cheuse a son emplacement final Ne pas craser ni pincer le conduit d vacuation V rifier que la s cheuse est d aplomb 41 EXIGENCES CONCERNANT LEVACUATION DE LA SECHEUSE Si on ne peut
29. installed by a qualified electrician SAVE THESE INSTRUCTIONS ELECTRIC DRYER ELECTRICAL REQUIREMENTS U S A ONLY Electric Dryer Power Supply Cord WARNING Fire Hazard Use a new UL listed 30 amp power supply cord Use a UL listed strain relief Disconnect power before making electrical connections Connect neutral wire white or center wire to center terminal Ground wire green or bare wire must be connected to green ground connector Connect remaining 2 supply wires to remaining 2 terminals gold Securely tighten all electrical connections Failure to do so can result in death fire or electrical shock If using a power supply cord Use a UL listed power supply cord kit marked for use with clothes dryers The kit should contain m A UL listed 30 amp power supply cord rated 120 240 volt minimum The cord should be type SRD or SRDT and be at least 4 ft 1 22 m long The wires that connect to the dryer must end in ring terminals or U shaped spade terminals with upturned ends A UL listed strain relief If your outlet looks like this Then choose a 4 wire power supply cord with ring or O spade terminals and UL listed strain relief The 4 wire power supply cord at least 4 ft 1 22 m long must have four 10 gauge copper wires and match a 4 wire receptacle of NEMA Type 14 30R The ground wire ground conductor may be either green or bare 4 wire a receptacle The neutra
30. jusqu l emplacement d installation de la s cheuse On doit utiliser un compos d tanch it des tuyauteries r sistant l action du gaz de p trole liqu fi Ne pas utiliser de ruban TEFLON Pour l alimentation au propane le diam tre des canalisations ou tuyaux doit tre de 1 2 13 mm minimum En g n ral le fournisseur de gaz propane d termine les mat riaux utiliser et le diam tre appropri pour le circuit Test de pressurisation de la canalisation de gaz Un piquage bouch de 1 8 NPT minimum accessible pour le contr le de pression doit tre install imm diatement en aval du robinet d arr t install pour la s cheuse comme illustr ci dessous Lors de toute preuve de pressurisation du syst me une pression sup rieure 1 2 Ib po 352 kg m on doit d connecter la s cheuse de la tuyauterie de l alimentation en gaz M thode alternative L alimentation en gaz peut aussi tre raccord e l aide d un conduit en cuivre ou en aluminium homologu de 3 8 10 mm Si la longueur totale de la canalisation d alimentation est sup rieure 20 pi 6 1 m utiliser un conduit de taille sup rieure Pour le gaz naturel ne pas utiliser de conduits en cuivre On doit utiliser un compos d tanch it des tuyauteries r sistant l action du gaz d alimentation Robinet d arr t n cessaire La canalisation d alimentation doit comporter un robinet d arr t individuel manuel install
31. pas utiliser de clapet d vacuation L ext rieur du conduit d vacuation principal doit comporter un conduit de d viation orient vers le bas A 24 min 12 min 610 mm 305 mm ae re Distance de d gagement minimale au dessus d une accumulation de neige de glace ou de d bris tels des feuilles Si le conduit principal monte verticalement travers le toit et non travers le mur installer un coude de d viation 180 l extr mit du conduit d au moins 2 pi 610 mm au dessus de la surface ou du toit Le diam tre de l ouverture dans le toit ou le mur doit tre sup rieur de 1 2 13 mm celui du conduit Le conduit doit tre centr dans l ouverture Pour de meilleures performances ne pas installer de grillage l extr mit de l vacuation vacuation pour plusieurs s cheuses On peut utiliser un conduit principal pour assurer l vacuation d un ensemble de s cheuses La taille du conduit principal doit permettre une vacuation de 200 CFM d air pour chaque s cheuse On peut utiliser des filtres charpie haute capacit correctement con us dans le conduit principal s ils sont inspect s et nettoy s r guli rement La pi ce dans laquelle se trouvent les s cheuses doit comporter un syst me d air d appoint au moins gal au CFM de toutes les s cheuses qui se trouvent dans la pi ce Un ensemble clapet anti retour r f rence n 3391910 est disponible aupr s de vot
32. suivant OPTION GLISSIERE A PIECES Cette option est soit non s lectionn e OFF soit s lectionn e ON Non s lectionn e OFF S lectionn e ON E Appuyer trois fois de suite sur le bouton DELICATES articles d licats pour cette s lection Une fois le mode glissi re pi ces s lectionn param trer b sur la valeur d une descente en pi ces de 5 cents R glez les codes 606 REGULAR CYCLE PRICE prix du programme normal et 3 06 SPECIAL CYCLE PRICE prix du programme sp cial sur le nombre de descente de pi ces REMARQUE Si l installateur r gle CS sur un mod le de chute de pi ces les pi ces ne sont pas enregistr es E Appuyer une fois sur le bouton PERM PRESS presse permanente pour passer au code suivant OPTIONS NOMBRE DE PI CES Cette option est soit non s lectionn e OFF soit s lectionn e ON Avec cette option l affichage client indique le nombre de pi ces pi ce 1 ins rer plut t que le montant en dollars et cents Le nombre affich change mesure que les pi ces sont ins r es Non s lectionn e OFF S lectionn e ON M Appuyer sur le bouton DELICATES articles d licats 3 fois de suite pour changer cette s lection E Appuyer une fois sur le bouton PERM PRESS presse permanente pour passer au code suivant Code J Cd J Cd J C Jd J Ed L 00 L 00 L PS n CE n 00
33. sur le bouton PERM PRESS presse permanente pour passer au code suivant OPTION D AFFICHAGE DU COFFRE Cette option est soit non s lectionn e OFF soit s lectionn e ON Non s lectionn e OFF S lectionn e ON E Appuyer une fois sur le bouton DELICATES articles d licats pour changer cette s lection Lorsque cette option est s lectionn e le compteur de monnaie et ou de programmes peut tre affich si les options de compteur correspondantes sont s lectionn es lorsque la bo te monnaie est retir e E Appuyer une fois sur le bouton PERM PRESS presse permanente pour passer au code suivant 51 INSTRUCTIONS DE R GLAGE DU TABLEAU DE COMMANDE ELECTRONIQUE Code b 05 b 05 C 20 C 20 d 00 d 00 d CS E 00 E 00 E AC 52 Explication VALEUR DE LA PI CE 1 Repr sente la valeur de la pi ce 1 en nombre de pi ces de 0 05 05 0 25 E En appuyant sur le bouton WHITES AND COLORS blancs et couleurs s lectionner entre 1 et 199 pi ces de 0 05 E Appuyer une fois sur le bouton PERM PRESS presse permanente pour passer au code suivant VALEUR DE LA PIECE 2 Repr sente la valeur de la pi ce 2 en nombre de pi ces de 0 05 20 1 00 E En appuyant sur le bouton WHITES AND COLORS blancs et couleurs s lectionner entre 1 et 199 pi ces de 0 05 E Appuyer une fois sur le bouton PERM PRESS presse permanente pour passer au code
34. ANNULATION D AVOIR Cette option est soit non s lectionn e OFF soit s lectionn e ON Lorsque cette option est s lectionn e l argent m moris en avoir pendant 30 minutes sans ajout suppl mentaire ou activit s de programme est effac Non s lectionn e OFF S lectionn e ON E Appuyer une fois sur le bouton DELICATES articles d licats pour changer cette s lection E Appuyer une fois sur le bouton PERM PRESS presse permanente pour passer au code suivant INSTRUCTIONS DE R GLAGE DU TABLEAU DE COMMANDE LECTRONIQUE FIN des OP RATIONS DE PARAM TRAGE QUITTER LE MODE DE PARAM TRAGE Mod les superpos es Faire tourner de nouveau la cl du panneau de l ouverture d acc s la position initiale GUIDE DE DIAGNOSTIC Si le mode de param trage est saisi et si l une des situations suivantes s est produite le code de diagnostic correspondant est affich S CHEUSES SUPERPOS ES CODE EXPLICATION d1 F 01 Etat du circuit de la porte non valide le module de commande ne fait pas la diff rence entre tat non valide et tat de porte ouverte d4 F 01 Erreur MCC le module de commande Sahara envoie cette erreur lorsque le circuit de r troaction du moteur d tecte une tension alors que la porte est ouverte ou que le moteur ne devrait tre en marche Le module de commande ne sait pas si le relais est d fectueux coll si le circuit d alimentation du rela
35. Canadian Natural Gas and Propane Installation Code CSA B149 1 The dryer must be electrically grounded in accordance with local codes or in the absence of local codes with the National Electrical Code ANSI NFPA 70 or Canadian Electrical Code CSA C22 1 IMPORTANT When discarding or storing your old clothes dryer remove the door DRYER SAFETY IMPORTANT SAFETY INSTRUCTIONS WARNING To reduce the risk of fire electric shock or injury to persons when using the dryer follow basic precautions including the following Read all instructions before using the dryer This dryer is intended only for drying clothes and textiles that have been washed in water Do not use for any other purpose WARNING If you smell gas do not use the dryer or any electrical equipment nearby Warn other people to clear the area Contact the dryer owner immediately Do not place items exposed to cooking oils in your dryer Items contaminated with cooking oils may contribute to a chemical reaction that could cause a load to catch fire Do not dry articles that have been previously cleaned in washed in soaked in or spotted with gasoline dry cleaning solvents other flammable or explosive substances as they give off vapors that could ignite or explode Do not dry unwashed items in the dryer Do not allow children to play on or in the dryer Close supervision of children is necessary when the dryer is used near children Before the dryer is re
36. ERTISSEMENT L odorat ne permet pas toujours la d tection d une fuite de gaz Les distributeurs de gaz recommandent l emploi d un d tecteur de gaz homologation UL ou CSA Pour d autre information contacter le fournisseur de gaz local En cas de d tection d une fuite de gaz ex cuter les instructions Que faire dans le cas d une odeur de gaz Dans l tat du Massachusetts les instructions d installation suivantes sont applicables m Les travaux d installation et r paration doivent tre ex cut s par un plombier ou tuyauteur qualifi ou licenci ou par le personnel qualifi d une entreprise licenci e par l tat du Massachusetts m Si une vanne boisseau sph rique est utilis e elle doit comporter une manette T m Si un conduit de raccordement flexible est utilis sa longueur ne doit pas d passer 3 pi IMPORTANT L installation du gaz doit se conformer aux codes locaux ou en l absence de codes locaux au code canadien d installation B149 1 du gaz naturel ou du propane La s cheuse doit tre lectriquement reli e la terre conform ment aux codes locaux ou en l absence de codes locaux au Code canadien de l lectricit CSA C22 1 IMPORTANT Pour mettre l ancienne s cheuse au rebut ou pour la remiser enlever la porte 32 S CURIT DE LA S CHEUSE IMPORTANTES INSTRUCTIONS DE S CURIT AVERTISSEMENT Pour r duire les risques d incendie de choc lectrique ou de blessure
37. ESD problems are present everywhere ESD may damage or weaken the electronic control assembly The new control assembly may appear to work well after repair is finished but failure may occur at a later date due to ESD stress E Use an anti static wrist strap Connect wrist strap to green ground connection point or unpainted metal in the appliance OR Touch your finger repeatedly to a green ground connection point or unpainted metal in the appliance E Before removing the part from its package touch the anti static bag to a green ground connection point or unpainted metal in the appliance E Avoid touching electronic parts or terminal contacts handle electronic control assembly by edges only E When repackaging failed electronic control assembly in anti static bag observe above instructions General User Information BLANK DISPLAY This condition indicates the dryer is inoperative Enter set up mode to view diagnostic code 0 MINUTES SHOWING IN DISPLAY This indicates the cycle is complete and the dryer cannot be operated Coins dropped or debit inputs during this condition will be stored in escrow but cannot be used until normal operation is restored by opening and closing the door If a door switch has failed it must be replaced before normal operation can be restored COLD START Initial first use Dryer is programmed at the factory as follows 5 minutes dry time quarter coin 1 1 50 dry price fixed c
38. LOCATION REQUIREMENTS WARNING Explosion Hazard Keep flammable materials and vapors such as gasoline away from dryer Do not install in a garage Failure to do so can result in death explosion or fire Your dryer can be installed in a basement laundry room or recessed area This dryer is not intended for installation in a mobile home Companion appliance location requirements should also be considered IMPORTANT E Do not install or store the dryer where it will be exposed to water and or the weather Proper installation is your responsibility M This dryer must not be installed in a closet with a door You will need E A grounded electrical outlet located within 6 ft 1 8 m of where the power cord is attached to the back of the dryer See Electrical Requirements M A level floor with a maximum slope of 1 25 mm under entire dryer Installing the dryer on soft floor surfaces such as carpets or surfaces with foam backing is not recommended Dryer installation clearances M The location must be large enough to allow the dryer door to be fully opened M Additional spacing should be considered for ease of installation and servicing The door opens more than 180 M Additional clearances might be required for wall door and floor moldings B Additional spacing of 1 25 mm on all sides of the dryer is recommended to reduce noise transfer When installing a gas dryer IMPORTANT Obse
39. SEMENT Risque d explosion Utiliser une canalisation neuve d arriv e de gaz approuv e par CSA International Installer un robinet d arr t Bien serrer chaque organe de connexion de la canalisation de gaz En cas de connexion au gaz propane demander une personne qualifi e de s assurer que la pression de gaz ne d passe pas 330 mm 13 po de la colonne d eau Par personne qualifi e on comprend le personnel autoris de chauffage le personnel autoris d une compagnie de gaz et le personnel d entretien autoris Le non respect de ces instructions peut causer un d c s un explosion ou un incendie IMPORTANT Observer les dispositions de tous les codes et r glements en vigueur L installation doit satisfaire aux crit res de tous les codes et r glements locaux En l absence de code local l installation doit satisfaire aux prescriptions de la norme American National Standard National Fuel Gas Code ANSI Z223 1 NFPA 54 ou CAN CSA B149 Pour obtenir un exemplaire des normes des codes ci dessus contacter National Fire Protection Association One Batterymarch Park Quincy MA 02269 CSA International 8501 East Pleasant Valley Road Cleveland Ohio 44131 5575 La conception de cette s cheuse a t homologu e par CSA International pour une utilisation jusqu une altitude de 10 000 pieds 3 048 m au dessus du niveau de la mer pour le d bit thermique indiqu sur la plaque signal tique Aucun r
40. affichage indique le prix UPPER DRYER LOWER DRYER INSTRUCTIONS DE R GLAGE DU TABLEAU DE COMMANDE LECTRONIQUE Proc dures de param trage des commandes IMPORTANT Lire toutes les instructions avant la mise en marche Les boutons de r glage du tissu associ s l affichage num rique servent r gler les commandes de la s cheuse L affichage peut contenir 4 chiffres et ou lettres et un point d cimal Il indique les codes de param trage et les valeurs correspondantes pour la programmation de l appareil Utilisation des boutons pour la programmation des commandes 1 Le bouton WHITES AND COLORS blancs et couleurs sert r gler les valeurs associ es aux codes de param trage En appuyant sur le bouton la valeur change par incr ments d un Un r glage rapide possible en maintenant le bouton enfonc 2 Le bouton PERM PRESS presse permanente fait d filer les codes de param trage En appuyant sur le bouton avancent au code de param trage suivant Maintenir le bouton PERM PRESS presse permanente enfonc pour faire d filer automatiquement les codes de param trage une vitesse sup rieure 1 par seconde 3 Le bouton DELICATES articles d licats sert s lectionner ou d s lectionner les options IMPORTANT Ne pas ouvrir la console avant d avoir d connect la s cheuse detoute source d nergie Pour acc der au connecteur AA gt D brancher la s cheuse ou d connecter la source
41. alimentation lectrique 4 fils ou 8 fils et tre Capable de supporter un courant nominal de 60 amp res minimum M En cuivre gaine non m tallique ou blind souple avec fil de liaison la terre avec conduit m tallique souple Tous les fils sous tension doivent tre isol s m En fil en cuivre massif de calibre 6 ne pas utiliser d aluminium E D au moins 5 pi 1 52 m de long 39 EXIGENCES CONCERNANT LEVACUATION DE LA SECHEUSE AVERTISSEMENT Risque d incendie Utiliser un conduit d vacuation en m tal lourd Ne pas utiliser un conduit d vacuation en plastique Ne pas utiliser un conduit d vacuation en feuille de m tal Le non respect de ces instructions peut causer un d c s ou un incendie AVERTISSEMENT Pour r duire le risque d incendie cette s cheuse doit EVACUER L AIR A LEXTERIEUR IMPORTANT Observer les dispositions de tous les codes et r glements en vigueur Le conduit d vacuation de la s cheuse ne doit pas tre raccord une vacuation de gaz une chemin e un mur un plafond un grenier un vide sanitaire ou un vide de construction Seul un conduit d vacuation m tallique rigide ou souple doit tre utilis pour le syst me d vacuation 4 102 mm Conduit d vacuation en m tal lourd de 4 102 mm Utiliser uniquement un conduit d vacuation en m tal lourd de 4 102 mm et des brides de serrage E Ne pas utiliser de conduit de plastique
42. ardless of the cost required to start the dryer No credit is given for coins or debit inputs entered when the control is displaying 99 minutes Penny increment offset is not applied to top off purchases FREE CYCLES This is established by setting the cycle price to zero When this happens SELECT CYCLE will appear rather than a cycle price Any cycle started as a free cycle will automatically terminate when the door is opened DEBIT CARD READY This dryer is debit card ready It will accept a variety of debit card systems but does NOT come with a debit card reader Refer to the debit card reader manufacturer for proper dryer setup In models converted to a Generation 1 debit card system debit pulses represent the equivalent of one coin coin 1 Display Once the unit has been plugged in and the dryer door opened and closed the display will show the price UPPER DRYER LOWER DRYER 25 ELECTRONIC CONTROL SETUP INSTRUCTIONS Control Set up Procedures IMPORTANT Read all instructions before operating The fabric setting buttons along with the digital display are used to set up the dryer controls The display can contain 4 numbers and or letters and a decimal point These are used to indicate the set up codes and related code values available for use in programming the appliance How to Use the Buttons to Program the Controls 1 The WHITES AND COLORS button is used to adjust the values associated with set up c
43. d for best drying performance and to avoid crushing and kinking Flexible metal vent Acceptable only if accessible to clean E Must be fully extended and supported in final dryer location m Remove excess to avoid sagging and kinking that may result in reduced airflow and poor performance E Do not install in enclosed walls ceilings or floors E The total length should not exceed 7 ft 2 4 m NOTE If using an existing vent system clean lint from entire length of the system and make sure exhaust hood is not plugged with lint Replace plastic or metal foil vents with rigid metal or flexible metal vents Review Vent System Chart and if necessary modify existing vent system to achieve best drying performance Elbows E 45 elbows provide better airflow than 90 elbows Good Better Clamps E Use clamps to seal all joints M Exhaust vent must not be connected or secured with screws or other fastening devices that extend into interior of duct and catch lint Do not use duct tape x0 Improper venting can cause moisture and lint to collect indoors which may result in E Moisture damage to woodwork furniture paint wallpaper carpets etc E Housecleaning problems and health problems 13 DRYER VENTING REQUIREMENTS Vent Hoods 4 102 mm Diameter Exhaust Hoods Louvered hood Box hood Angled hood Vent System Length Maximum Vent Length Vent Connection Maximum length of vent system depends
44. dryer This dryer must be connected to a grounded metal permanent wiring system or an equipment grounding conductor must be run with the circuit conductors and connected to the equipment grounding terminal or lead on the dryer WARNING Improper connection of the equipment grounding conductor can result in a risk of electric shock Check with a qualified electrician or service representative or personnel if you are in doubt as to whether the dryer is properly grounded Do not modify the plug on the power supply cord if it will not fit the outlet have a proper outlet installed by a qualified electrician SAVE THESE INSTRUCTIONS GAS REQUIREMENTS Gas Supply A WARNING Explosion Hazard Use a new CSA International approved gas supply line Install a shut off valve Securely tighten all gas connections If connected to LP have a qualified person make sure gas pressure does not exceed 13 330 mm water column Examples of a qualified person include licensed heating personnel authorized gas company personnel and authorized service personnel Failure to do so can result in death explosion or fire IMPORTANT Observe all governing codes and ordinances This installation must conform with all local codes and ordinances In the absence of local codes installation must conform with American National Standard National Fuel Gas Code ANSI Z223 1 NFPA 54 or CAN CSA B149 A copy of the above code standards can b
45. e de bois de 27 686 mm Couteau mastic des tuyauteries r sistant au type de gaz utilis R gle ou m tre ruban TORX et T 20 sont des marques d pos es de Acument Intellectual Properties LLC 34 DIMENSIONS DISTANCES DE D GAGEMENT Dimensions Vue de face Vue lat rale Vue arri re 51 2 27 gt 87 8 140 mm 686 mm 225 mm 131 2 343 mm je 101 2 267 mm 768 4 i 1 950 mm l 1 ry Le 18 5 460 mm mm 25 mm es r 233 4 E a 603 mm 79 mm Distances de d gagement Encastrement vue avant Encastrement vue lat rale 35 EXIGENCES DE L EMPLACEMENT AVERTISSEMENT Risque d explosion Garder les mati res et les vapeurs inflammables telle que l essence loin de la s cheuse Ne pas installer dans un garage Le non respect de ces instructions peut causer un d c s une explosion ou un incendie La s cheuse peut tre install e dans un sous sol une salle de buanderie ou un encastrement Cette s cheuse n est pas pr vue pour une installation en r sidence mobile Il faut aussi prendre en compte les exigences d emplacement des appareils voisins IMPORTANT E Ne pas installer ou remiser la s cheuse dans un endroit o elle sera expos e l eau et ou aux intemp ries C est l utilisateur qu incombe la responsabilit de r aliser une installation correcte
46. e obtained from National Fire Protection Association One Batterymarch Park Quincy MA 02269 CSA International 8501 East Pleasant Valley Road Cleveland Ohio 44131 5575 The design of this dryer has been certified by CSA International for use at altitudes up to 10 000 feet 3048 m above sea level at the B T U rating indicated on the model serial plate Burner input adjustments are not required when the dryer is operated up to this elevation When installed above 10 000 feet 8048 m a four percent 4 reduction of the burner B T U rating shown on the model serial plate is required for each 1 000 foot 305 m increase in elevation For assistance when converting to other gas types and or installing above 10 000 feet 3048 m elevation contact your local service company ELECTRIC DRYER ELECTRICAL REQUIREMENTS U S A ONLY It is your responsibility E To contact a qualified electrical installer E To be sure that the electrical connection is adequate and in conformance with the National Electrical Code ANSI NFPA 70 latest edition and all local codes and ordinances The National Electrical Code requires a 4 wire power supply connection for homes built after 1996 dryer circuits involved in remodeling after 1996 and all mobile home installations E A copy of the above code standards can be obtained from National Fire Protection Association One Batterymarch Park Quincy MA 02269 To supply the required 3 or 4 wire
47. e risk of fire or explosion or to prevent property damage personal injury or death Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance WHAT TO DO IF YOU SMELL GAS e Do not try to light any appliance e Do not touch any electrical switch do not use any phone in your building e Clear the room building or area of all occupants e Immediately call your gas supplier from a neighbor s phone Follow the gas supplier s instructions e If you cannot reach your gas supplier call the fire department Installation and service must be performed by a qualified installer service agency or the gas supplier WARNING Gas leaks cannot always be detected by smell Gas suppliers recommend that you use a gas detector approved by UL or CSA For more information contact your gas supplier If a gas leak is detected follow the What to do if you smell gas instructions In the State of Massachusetts the following installation instructions apply m Installations and repairs must be performed by a qualified or licensed contractor plumber or gasfitter qualified or licensed by the State of Massachusetts m If using a ball valve it shall be a T handle type m A flexible gas connector when used must not exceed 3 feet IMPORTANT The gas installation must conform with local codes or in the absence of local codes with the National Fuel Gas Code ANSI Z223 1 NFPA 54 or the
48. es trois caract res situ s le plus droite correspondent a la valeur du code de configuration Code Explication 606 PRIX DU PROGRAMME NORMAL 606 Repr sente le nombre de pi ces de 0 25 pi ce 1 n cessaires pour mettre en marche la s cheuse r glable de 0 39 voir VALEUR DE LA PIECE 1 b 05 Avancer de 0 39 en appuyant sur le bouton WHITES AND COLORS blancs et couleurs Valeur par d faut d finie en usine sur 6 pi ces de 0 25 1 50 E Appuyer une fois sur le bouton PERM PRESS presse permanente pour passer au code suivant 705 DUREE DE SECHAGE NORMAL 705 Repr sente le nombre de minutes par pi ce de 0 25 pi ce 1 Le r glage par d faut en usine est de 5 minutes par pi ce Par exemple 6 pi ces de 0 25 x 5 minutes 30 minutes En appuyant sur le bouton WHITES AND COLORS blancs et couleurs r gler la valeur entre 1 et 99 minutes E Appuyer une fois sur le bouton PERM PRESS presse permanente pour passer au code suivant 49 INSTRUCTIONS DE R GLAGE DU TABLEAU DE COMMANDE LECTRONIQUE Code Explication 800 TYPE DE TARIF DE LA S CHEUSE 800 Programme fixe avec appoint Pour une description d taill e consulter les Informations g n rales d utilisation 8FC Programme fixe Voir la description d taill e dans Information g n rale pour l utilisateur Utiliser la touche DELICATES pour effectuer cette s lection E Appuyer une fois sur le bouton PERM PRESS
49. essed by pressing the LOWER DRYER buttons The set up code is indicated by the one or two left hand characters The set up code value is indicated by the two or three right hand characters 26 Code Explanation 606 REGULAR CYCLE PRICE 606 Represents the number of quarters coin 1 needed to start the dryer may adjust from 0 39 See VALUE OF COIN 1 b 05 Advance from 0 39 by pressing the WHITES AND COLORS button Factory default of 6 quarters 1 50 E Press the PERM PRESS button once to advance to next code 705 REGULAR DRY TIME 705 Represents the number of minutes per quarter coin 1 Factory default of 5 minutes per coin Example 6 quarters x 5 minutes 30 minutes By pressing the WHITES AND COLORS button value adjusts from 1 99 minutes E Press the PERM PRESS button once to advance to next code 800 TYPE OF DRYER PRICING 800 Fixed Cycle with Top Off For detailed description see General User Information 8FC Fixed Cycle For detailed description see General User Information Use DELICATES button to make this selection E Press the PERM PRESS button once to advance to next code 9 00 CYCLE COUNTER OPTION This option is either NOT SELECTED OFF or SELECTED ON 900 Not Selected OFF 9 OC Selected ON and not able to be deselected E Press the DELICATES button 3 consecutive times to select ON Once selected ON it cannot be deselected E Press the PERM PRESS
50. ey counter 1 0C or 1 C0 is selected the following is true 3 00 Dollars in HJNDREDS 3 01 100 00 400 Dollars in ONES 4 68 00 5 00 Number of CENTS 5 75 00 75 TOTAL 168 75 Code 3 06 3 06 4 05 4 05 5 00 5 00 6 00 6 00 Explanation SPECIAL CYCLE PRICE Represents the number of quarters coin 1 to start the dryer may adjust from 0 39 See VALUE OF COIN 1 b 05 Advance from 0 39 by pressing the WHITES AND COLORS button Factory default of 6 quarters 1 50 E Press the PERM PRESS button once to advance to next code SPECIAL DRY TIME Represents the number of minutes per quarter coin 1 E Factory default of 5 minutes per coin Example 6 quarters x 5 minutes 30 minutes E By pressing the WHITES AND COLORS button the value can be adjusted from 1 99 minutes E Press the PERM PRESS button once to advance to next code TIME OF DAY CLOCK MINUTES This is the TIME OF DAY CLOCK minute setting select 0 59 minutes by pressing the WHITES AND COLORS button E Press the PERM PRESS button once to advance to next code TIME OF DAY CLOCK HOURS NOTE Uses military time or 24 hr clock This is the TIME OF DAY CLOCK hour setting select 0 23 hours by pressing the WHITES AND COLORS button E Press the PERM PRESS button once to advance to next code 27 ELECTRONIC CONTROL SETUP INSTRUCTIONS Code 7 00 7 00 8 00 8 00 9 10 9 10 Explanation SPECIAL PRICE
51. ge avant la fin du programme de s chage sauf si tous les articles sont retir s rapidement et r partis pour une dissipation de la chaleur permet d viter le risque de combustion spontan e Ne pas laisser la charpie la poussi re ou la salet s accumuler autour du syst me d vacuation ou autour de l appareil Un nettoyage p riodique de l int rieur de la s cheuse et du conduit d vacuation doit tre effectu par une personne qualifi e Voir la section Sp cifications lectriques dans les instructions d installation pour les instructions de mise la terre CONSERVEZ CES INSTRUCTIONS 33 OUTILS ET PI CES Outillage n cessaire Cl tuyau de 8 200 mm ou 10 250 mm E Tournevis isol ou foret Torx T 20 6 i Niveau O Pistolet calfeutrage et compos de calfeutrage pour l installation d un nouveau conduit d vacuation C Lampe de poche facultative Pi ces fournies Goupille fendue 2 Cl molette de 8 200 mm ou 10 250 mm ouverture jusqu 1 25 mm Cl douille hexagonale de 1 25 mm CSN Couteau utilitaire Brides de conduit Gy AS Cl s plates de 1 25 mm Sa Tournevis a lame plate Tournevis Phillips oo AS gt Pince ouverture jusqu 1 16 39 mm Cl douille de 5 16 8 mm Tourne crou de 1 4 6 mm J Compos d tanch it Cal
52. glage du br leur n est n cessaire lorsque la s cheuse est utilis e une altitude inf rieure ou gale cette valeur maximale Lorsque l appareil est install une altitude sup rieure 10 000 pieds 3 048 m on doit r duire de 4 le d bit thermique du br leur indiqu sur la plaque signal tique pour chaque tranche de 1 000 pieds 305 m d augmentation de l altitude Pour obtenir de l aide lors de la conversion d autres types de gaz et ou l installation de l appareil une altitude sup rieure 10 000 pieds 3048 m contacter la soci t de d pannage la plus proche 38 EXIGENCES LECTRIQUES POUR LA S CHEUSE LECTRIQUE Raccordement par c blage direct AVERTISSEMENT Risque d incendie Utiliser du fil en cuivre solide de calibre 6 Utiliser un r ducteur de tension homologu UL D connecter la source de courant lectrique avant de r aliser les connexions lectriques Connecter le conducteur neutre blanc ou conducteur central la borne centrale Le conducteur de liaison la terre vert ou nu doit tre reli au connecteur vert de liaison la terre Connecter les 2 conducteurs d alimentation restants aux 2 bornes or restantes Bien serrer chaque organe de connexion du branchement lectrique Le non respect de cette instruction peut causer un d c s un incendie ou un choc lectrique Pour le raccordement direct Le c ble d alimentation doit correspondre l
53. ically by qualified service personnel See Electrical Requirements section for grounding instructions SAVE THESE INSTRUCTIONS TOOLS amp PARTS Tools Needed 8 200 mm or 10 250 mm Pipe wrench E Torx T 20 security screwdriver or bit Level q Caulk gun and caulk for installing new exhaust vent C Flashlight optional Parts Supplied Security cotter pins 2 8 200 mm or 10 250 mm Adjustable wrench that opens to 1 25 mm 1 25 mm Hex head socket wrench AEN Utility knife Vent clamps Fas 1 25 mm Open end wrenches E gt Flat blade screwdriver SS 5 16 8 mm Socket wrench 1 4 6 mm Nut driver Pipe joint compound suitable for gas type i Ruler or measuring tape TORX and T 20 are registered trademarks of Acument Intellectual Properties LLC Phillips screwdriver SS Pliers that open to 19 16 39 mm 27 686 mm Wood block Putty knife DIMENSIONS CLEARANCES Dimensions Front View Side View Back View 51 2 Leg 27 gt He 87 8 140 mm 686 mm 225 mm 131 2 343 mm 101 2 267 mm 768 4 1950 mm t I I 4181 460 mm 37 940 mm 1 25 mm i 1 er 233 4 E 31 3 603 mm 32 mm 79 mm Clearances Recessed Front View Recessed Side View 0 mm 0 mm
54. install conform ment aux instructions d installation fournies Dommages entra n s par l exposition du produit des produits chimiques Des modifications apport es l immeuble la pi ce ou aux lieux afin de permettre l appareil m nager usage commercial de fonctionner correctement 10 Les pi ces de rechange sp cifi es par l usine pour les appareils m nagers usage commercial dont les num ros de s rie et de mod le d origine ont t supprim s modifi s ou qui ne peuvent pas tre facilement identifi s 11 La d coloration au l oxydation de surfaces en acier inoxydable ou encore l apparition de rouille sur ces surfaces 12 Les pi ces de rechange sp cifi es par l usine suite un diagnostic erron ou une r paration erron effectu e par un service de d pannage hors r seau Le co t d une r paration ou d un remplacement dans le cadre de ces circonstances exclues est la charge du client gt po NO CLAUSE D EXONERATION DE RESPONSABILITE AU TITRE DES GARANTIES IMPLICITES LES GARANTIES IMPLICITES Y COMPRIS LES GARANTIES APPLICABLES DE QUALIT MARCHANDE OU D APTITUDE UN USAGE PARTICULIER SONT LIMITEES A UN AN OU ALA PLUS COURTE PERIODE AUTORISEE PAR LA LOI Certains Etats et certaines provinces ne permettent pas de limitation sur la dur e de garanties implicites de qualit marchande ou d aptitude un usage particulier de sorte que la limitation ci dessus peut ne pas tre applicable
55. ionner ON et bloquer l option sur cette valeur s lectionner d abord ON et en moins de 2 secondes appuyer deux fois sur le bouton DELICATES articles d licats et une fois sur le bouton WHITES AND COLORS blancs et couleurs puis quitter le mode de param trage E Appuyer une fois sur le bouton PERM PRESS presse permanente pour passer au code suivant 2 00 OPTIONS DE TARIF SPECIAL Cette option est soit non s lectionn e OFF soit s lectionn e ON 2 00 Non s lectionn e OFF et le code suivant sera A 00 2 SP S lectionn e ON E Appuyer une fois sur le bouton DELICATES articles d licats pour changer cette s lection Si l option de tarif sp cial est s lectionn e les codes 3 XX 9 XX sont accessibles E Appuyer une fois sur le bouton PERM PRESS presse permanente pour passer au code suivant Si le compteur de monnaie 1 0C ou 1 C0 est s lectionn le calcul du total est le suivant 3 00 CENTAINES de dollars 3 01 100 00 4 00 Dollars UNITAIRES 468 68 00 5 00 Nombre de CENTS 575 00 75 TOTAL 168 75 INSTRUCTIONS DE R GLAGE DU TABLEAU DE COMMANDE OPTIONS 3 XX 9 XX UTILISER EN CAS DE S LECTION DE TARIF SPECIAL Code 3 06 3 06 4 05 4 05 5 00 5 00 6 00 6 00 7 00 7 00 Explication PRIX DU PROGRAMME SP CIAL Repr sente le nombre de pi ces de 0 25 pi ce 1 pour mettre en marche la s cheuse r
56. irflow Vents entering from the opposite side should be staggered to reduce the exhausted air from interfering with the other vents The maximum angle of each vent entering the main vent should be no more than 30 Keep air openings free of dry cleaning fluid fumes Fumes create acids which when drawn through the dryer heating units can damage dryers and items being dried A clean out cover should be located on the main vent for periodic cleaning of the vent system GAS SUPPLY CONNECTION Make Gas Connection A WARNING Excessive Weight Hazard Use two or more people to move and install dryer Failure to do so can result in back or other injury 1 Remove red cap from gas pipe on back of dryer 2 Connect gas supply to dryer Use a pipe thread compound approved for the type of gas supplied If flexible metal tubing is used be certain there are no kinks If necessary for service open the toe panel Use a putty knife to press on the toe panel locks located at the upper corners of the toe panel Pull downward on the toe panel to open Toe panel is hinged at the bottom 3 Open the shut off valve in the gas supply line and make sure the dryer has its own gas supply opened 4 Test all connections by brushing on an approved noncorrosive leak detection solution Bubbles will show a leak Correct any leaks found 15 GAS SUPPLY CONNECTION Type of Gas This dryer is equipped for use with natural gas It is de
57. is est d faillant en court circuit provoquant le blocage du relais du moteur en position active ou si le circuit de r troaction du relais est endommag fosse tension OO d12 F 01 Anomalie pi ce 2 d13 Erreur du circuit de d tection du moteur de la s cheuse sup rieure sur la carte de commande ou en raison d une interf rence de la ligne d alimentation programmes et affichage de la s cheuse sup rieure d sactiv s jusqu la r initialisation manuelle du code de diagnostic Carte de d bit de 2e g n ration d17 Erreur du circuit de d tection de position de la porte de la s cheuse inf rieure sur la carte de commande ou en raison d une interf rence de la ligne d alimentation programmes et affichage de la s cheuse inf rieure d sactiv s jusqu la r initialisation manuelle du code de diagnostic Erreur du circuit de commande du moteur de la s cheuse sup rieure programmes et affichage de la s cheuse sup rieure d sactiv s jusqu la r initialisation manuelle du code de diagnostic 53 54 _ GARANTIE DE LA LAVEUSE COMMERCIALE DE LA _ SECHEUSE DE LA SECHEUSE SECHEUSE SUPERPOSEE DE L ENSEMBLE DE BUANDERIE COMMERCIAL SUPERPOSE ET DES LAVEUSES ET SECHEUSES COMMERCIALES MULTI CHARGE PAYANTES MAYTAG GARANTIE LIMIT E PI CES UNIQUEMENT MAINS D OEUVRE NON INCLUS Pendant les cinq premi res ann es compter de la date d achat d origine lorsque cet appareil m nager usage comme
58. ispositif de serrage qui se prolongerait l int rieur du conduit et retiendrait la charpie Ne pas utiliser de ruban adh sif pour conduit 20 Q Une mauvaise vacuation de l air peut causer de l humidit et une accumulation de charpie l int rieur de la maison ce qui peut provoquer m Dommages par l humidit aux boiseries meubles peinture papier peint tapis etc E Probl mes de nettoyage dans la maison et probl mes de sant EXIGENCES CONCERNANT LEVACUATION DE LA SECHEUSE Hottes d extraction Clapets d vacuation Diam tre de 4 102 mm Clapet de type bo te Clapet persiennes Clapet inclin Longueur du syst me d vacuation Longueur maximale du conduit raccord La longueur maximale du syst me d vacuation d pend du type de conduit utilis du nombre de coudes et du type de clapet d vacuation Tableau des syst mes d vacuation conduit en m tal rigide Nbre de Clapet de type changements de bo te ou direction 90 persiennes Clapet inclin 0 130 pi 39 6 m 129 pi 39 3 m 125 pi 38 1 m 115 pi 35 1 m 106 pi 32 3 m 98 pi 29 9 m 119 pi 36 3 m 109 pi 33 2 m 100 pi 30 5 m 92 pi 28 m A N Pour les syst mes d vacuation autres que ceux indiqu s dans le tableau des syst mes d vacuation consulter le revendeur de pi ces Pr voir un espace suffisant pour la combustion et la ventilation de l air V rifier les dispositions des codes
59. ition du National Electrical Code ANSI NFPA 70 ou du Canadian Electrical Code CSA C22 1 Si les codes le permettent et si on utilise un conducteur distinct de liaison la terre il est recommand qu un lectricien qualifi v rifie la qualit de la liaison la terre Pour obtenir un exemplaire des normes des codes ci dessus contacter National Fire Protection Association One Batterymarch Park Quincy MA 02269 CSA International 8501 East Pleasant Valley Road Cleveland Ohio 44131 5575 E Ne pas utiliser une tuyauterie de gaz pour le raccordement la terre E Ne pas installer un fusible dans le conducteur neutre ou le circuit de liaison la terre E Une alimentation de 120 volts 60 Hz CA seulement de 15 ou 20 amp res prot g e par un fusible est requise On recommande galement d utiliser un fusible ou un disjoncteur temporis Il est recommand de raccorder la s cheuse sur un circuit distinct exclusif cet appareil E Siles codes le permettent et si l on utilise un conducteur distinct de liaison la terre il est recommand qu un lectricien qualifi v rifie la qualit de la liaison la terre E En cas de doute quant la qualit de la liaison la terre de la s cheuse consulter un lectricien qualifi Mise la terre de la s cheuse gaz INSTRUCTIONS DE LIAISON LA TERRE m Pour une s cheuse reli e la terre et connect e par un cordon Cette s cheuse doit tre reli e
60. jured if you don t follow A WARNING instructions All safety messages will tell you what the potential hazard is tell you how to reduce the chance of injury and tell you what can happen if the instructions are not followed A WARNING Risk of Fire Clothes dryer installation must be performed by a qualified installer Install the clothes dryer according to the manufacturer s instructions and local codes Do not install a clothes dryer with flexible plastic venting materials or flexible metal foil type duct If flexible metal duct is installed it must be of a specific type identified by the appliance manufacturer as suitable for use with clothes dryers Flexible venting materials are known to collapse be easily crushed and trap lint These conditions will obstruct clothes dryer airflow and increase the risk of fire To reduce the risk of severe injury or death follow all installation instructions Save these instructions E It is recommended that the owner post in a prominent location instructions for the customer s use in the event the customer smells gas This information should be obtained from your gas supplier E Post the following warning in a prominent location FOR YOUR SAFETY Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance DRYER SAFETY WARNING For your safety the information in this manual must be followed to minimize th
61. l conductor must be identified by a white 14 30R cover If your outlet looks like this Then choose a 3 wire power supply cord with ring or spade terminals and UL listed strain relief The 3 wire power supply cord at least 4 ft 1 22 m long must have three 10 gauge copper wires and match a 3 wire receptacle of NEMA Type 10 30R 3 wire receptacle 10 30R Direct Wire A WARNING Fire Hazard Use 10 gauge copper wire Use a UL listed strain relief Disconnect power before making electrical connections Connect neutral wire white or center wire to center terminal Ground wire green or bare wire must be connected to green ground connector Connect remaining 2 supply wires to remaining 2 terminals gold Securely tighten all electrical connections Failure to do so can result in death fire or electrical shock If connecting by direct wire Direct wire cable must match power supply 4 wire or 3 wire and be E Flexible armored cable or nonmetallic sheathed copper cable with ground wire covered with flexible metallic conduit All current carrying wires must be insulated M 10 gauge solid copper wire do not use aluminum E Atleast 5 ft 1 52 m long 11 ELECTRIC DRYER ELECTRICAL REQUIREMENTS CANADA ONLY Direct Wire A WARNING Fire Hazard Use 6 gauge copper wire Use a UL listed strain relief Disconnect power before making electrical connections Connect neutral wire white or cente
62. l heure de d but en appuyant sur le bouton WHITES AND COLORS blancs et couleurs E Appuyer une fois sur le bouton PERM PRESS presse permanente pour passer au code suivant Code 8 00 8 00 9 10 9 10 ELECTRONIQUE Explication HEURE DE FIN DU TARIF SPECIAL REMARQUE Utilise le format sur 24 heures Repr sente l heure de fin entre O et 23 heures E S lectionner l heure de fin en appuyant sur le bouton WHITES AND COLORS blancs et couleurs E Appuyer une fois sur le bouton PERM PRESS presse permanente pour passer au code suivant JOUR TARIF SP CIAL Repr sente le jour de la semaine et indique si un tarif sp cial est s lectionn pour ce jour Un nombre suivi de 0 indique l absence de s lection pour ce jour particulier 9 10 Un nombre suivi de S indique une s lection pour ce jour particulier 9 1S Les jours de la semaine 1 7 sont s lectionn s en appuyant sur le bouton WHITES AND COLORS blancs et couleurs Appuyer une fois sur le bouton DELICATES articles d licats pour s lectionner le prix sp cial pour chaque jour choisi En quittant le code de param trage 9 l affichage doit indiquer le jour actuel de la semaine JOUR DE LA CODE AFFICHAGE SEMAINE s lectionn 10 Jour 1 Dimanche 1S 20 Jour 2 Lundi 28 30 Jour 3 Mardi 3S 40 Jour 4 Mercredi 4S 50 Jour 5 Jeudi 5S 60 Jour 6 Vendredi 6S 70 Jour 7 Samedi 7S A 00 A 00 A SC E Appuyer une fois
63. ller maintenir la cale d espacement en carton centr e entre les portes Fixer nouveau le panneau de porte la porte interne de fa on ce que la poign e se trouve du c t o les vis viennent d tre retir es 8 Fixer nouveau les vis de chaque c t de la porte 5 vis 9 10 11 12 Fixer les charni res de porte la porte de la s cheuse de fa on ce que le trou le plus gros se trouve au fond de la charni re et que l axe de la charni re soit orient vers l avant de la porte ter les 4 vis fixant les 2 bouchons d obturation du c t de la poign e Fixer les bouchons d obturation au c t oppos l aide des m mes 4 vis Ins rer les vis dans les trous inf rieurs du c t gauche de la caisse Serrer les vis moiti Positionner la porte de fa on ce que le c t large de l encoche de la charni re de porte se trouve au dessus des vis Faire glisser la porte vers le haut de fa on ce que les vis se trouvent au fond des encoches Resserrer les vis Ins rer les vis sup rieures dans les charni res et serrer gt ae Fermer la porte et v rifier que la g che de la porte est align e avec le loquet Au besoin faire glisser le piton de retenue de la porte vers la gauche ou vers la droite l int rieur de l encoche pour r gler l alignement E Nettoyer le filtre charpie avant ou apr s chaque programme INSTRUCTIONS D ENTRETIEN Si la s cheuse
64. moved from service or discarded remove the doors to the dryer compartment Do not reach into the dryer if the drum is moving Do not open door while dryer is in operation It will stop Do not install or store the dryer where it will be exposed to water and or the weather Do not tamper with controls Clean dryer lint screen before or after each load Do not use this dryer without the lint screen in place Do not repair or replace any part of the dryer or attempt any servicing unless specifically recommended in this Installation Instructions or in published user repair instructions that you understand and have the skills to carry out Do not use fabric softeners or products to eliminate static unless recommended by the manufacturer of the fabric softener or product Do not use heat to dry articles containing foam rubber or similarly textured rubber like materials The final part of a tumble dryer cycle occurs without heat cool down cycle to ensure that the articles are left at a temperature that ensures that the items will not be damaged WARNING Never stop a tumble dryer before the end of the drying cycle unless all items are quickly removed and spread out so that the heat is dissipated Avoids risk of spontaneous combustion Keep area around the exhaust opening and adjacent surrounding areas free from the accumulation of lint dust and dirt The interior of the dryer and dryer exhaust vent should be cleaned period
65. n CE Explication MODE DE PAIEMENT OPTION DE PI CES D BIT Modes pi ces et carte de d bit s lectionn s Appuyer sur le bouton DELICATES articles d licats 3 fois de suite pour changer cette s lection Mode pi ces s lectionn mode carte de d bit d sactiv Appuyer sur le bouton DELICATES articles d licats 3 fois de suite pour changer cette s lection Mode carte de d bit s lectionn mode pi ces d sactiv Appuyer sur le bouton DELICATES articles d licats 3 fois de suite pour changer cette s lection L option d bit am lior est automatiquement s lectionn e lorsqu un lecteur de cartes de 2e g n ration est install dans la s cheuse L option Ed ne peut pas tre s lectionn e ou d sactiv e manuellement E Appuyer une fois sur le bouton PERM PRESS presse permanente pour passer au code suivant OPTION DE SUPPRESSION DU PRIX Cette option est soit non s lectionn e OFF soit s lectionn e ON Cette option indique sur l afficheur client ADD introduire ou AVAILABLE disponible au lieu du montant ajouter utilis principalement avec les installations carte de d bit Non s lectionn e OFF Suppression de prix s lectionn e ON E Appuyer une fois sur le bouton DELICATES articles d licats pour changer cette s lection E Appuyer une fois sur le bouton PERM PRESS presse permanente pour passer au code suivant OPTION D
66. nde que le propri taire place les instructions l usage du client en un lieu bien visible au cas o le client percevrait une odeur de gaz Ces renseignements doivent tre obtenus aupr s de votre fournisseur en gaz E Placer l avertissement qui suit un endroit bien visible POUR VOTRE S CURIT Ne pas remiser ou utiliser de l essence ou tout autre liquide ou vapeur inflammable proximit de cet appareil ou de tout autre appareil 31 S CURIT DE LA S CHEUSE AVERTISSEMENT Pour votre s curit les renseignements dans ce manuel doivent tre observ s pour r duire au minimum les risques d incendie ou d explosion ou pour viter des dommages au produit des blessures ou un d c s Ne pas entreposer ou utiliser de l essence ou d autres vapeurs ou liquides inflammables proximit de cet appareil ou de tout autre appareil lectrom nager QUE FAIRE DANS LE CAS D UNE ODEUR DE GAZ e Ne pas tenter d allumer un appareil e Ne pas toucher a un commutateur lectrique ne pas utiliser le telephone se trouvant sur les lieux e Evacuer tous les gens de la pi ce de l difice ou du quartier e Appeler imm diatement le fournisseur de gaz d un t l phone voisin Suivre ses instructions e d faut de joindre votre fournisseur de gaz appeler les pompiers L installation et l entretien doivent tre effectu s par un installateur qualifi une agence de service ou le fournisseur de gaz AV
67. ne fonctionne pas contr ler ce qui suit m Comment enlever la charpie accumul e M La prise de courant est correctement aliment e l int rieur de la caisse de la s cheuse Le disjoncteur ne s est pas d clench et aucun fusible n est Il faut retirer la charpie accumul e dans le conduit d vacuation grill tous les 2 ans ou plus souvent selon l utilisation de la E La porte est ferm e s cheuse Le nettoyage doit tre effectu par une personne E Les boutons de commande s lectionnent une configuration qualifi e de fonctionnement DEN 14 p e De l int rieur du conduit d vacuation E Un programme a t s lectionn Retirer la charpie tous les 2 ans ou plus souvent selon E Pour une s cheuse gaz v rifier que les robinets ptt a l utilisation de la s cheuse de la canalisation de gaz sont ouverts E D gager l espace autour de la s cheuse aucune mati re combustible essence ou autres vapeurs ou liquides inflammables ne doit s y trouver E D gager l emplacement de la s cheuse de fa on ce qu il soit libre de tout l ment susceptible d obstruer le d bit d air de combustion et de ventilation SI VOUS AVEZ BESOIN D ASSISTANCE Contacter le revendeur autoris d appareils de buanderie usage commercial Pour localiser votre revendeur autoris d appareils de buanderie usage commercial ou pour toute question via internet consulter www MaytagCommercialLaundry com Si vous ne parvenez pa
68. ode Pressing the button will change the value by increments of one 1 Rapid adjustment is possible by holding down the button 2 The PERM PRESS button will advance through the set up codes Pressing the button will advance to the next available set up code Holding down the PERM PRESS button will automatically advance through the set up codes at a rate faster than one 1 per second 3 The DELICATES button is used to select or deselect options IMPORTANT The console must not be opened unless power is first removed from the dryer To access connector AA1 gt Unplug dryer or disconnect power gt Open console disconnect plug on AA1 close console gt Plug in dryer or reconnect power M Insert access panel key and turn counterclockwise If manual set up card is not available manual set up mode can be entered by turning the access panel key The dryer is now in the set up mode NOTE This dryer is preset at the factory and does not require any programming However if you want to change the settings follow the Set Up Codes guide below M This dryer is pre set at the factory for fixed cycle price with top off Set Up Codes m The PERM PRESS button will advance you from code to code E The WHITES AND COLORS button will change the code value E The DELICATES button will select or deselect options NOTE On all stacked dryer models programming selections apply to both dryers Stacked dryer selections are acc
69. ommercial Laundry Pour localiser votre distributeur autoris de Maytag Commercial Laundry composer le 1 800 662 3587 ou pour toute question via internet consulter www MaytagCommercialLaundry com 02 14 Pour toute correspondance crite Maytag Commercial Laundry Service Department 2000 NM 63 Benton Harbor Michigan 49022 2632 USA 55 03 2015 Printed in U S A Imprim aux Etats Unis W10761035A TM 2015 Maytag All rights reserved W10761036A SP TM 2015 Maytag Tous droits r serv s
70. onnection section M A 4 wire power supply connection must be used when the appliance is installed in a location where grounding through the neutral conductor is prohibited Grounding through the neutral is prohibited for 1 new branch circuit installations and 2 areas where local codes prohibit grounding through the neutral conductor 10 Electric Dryer Grounding GROUNDING INSTRUCTIONS E For a grounded cord connected dryer This dryer must be grounded In the event of malfunction or breakdown grounding will reduce the risk of electric shock by providing a path of least resistance for electric current This dryer uses a cord having an equipment grounding conductor and a grounding plug The plug must be plugged into an appropriate outlet that is properly installed and grounded in accordance with all local codes and ordinances mE For a permanently connected dryer This dryer must be connected to a grounded metal permanent wiring system or an equipment grounding conductor must be run with the circuit conductors and connected to the equipment grounding terminal or lead on the dryer WARNING Improper connection of the equipment grounding conductor can result in a risk of electric shock Check with a qualified electrician or service representative or personnel if you are in doubt as to whether the dryer is properly grounded Do not modify the plug on the power supply cord if it will not fit the outlet have a proper outlet
71. ou de m tal tr s mince Conduit m tallique rigide E Recommand pour une performance de s chage id ale afin d viter tout crasement ou d formation Conduit m tallique flexible Acceptable uniquement si son acc s reste facile pour le nettoyage M Doit tre enti rement d ploy et soutenu l emplacement d installation final de la s cheuse M Enlever tout exc s de conduit flexible pour viter tout affaissement et d formation susceptible de r duire la capacit d vacuation et le rendement m Ne pas installer le conduit m tallique flexible dans des cavit s ferm es de mur plafonds ou planchers E La longueur totale ne doit pas d passer 7 pi 2 4 m 40 REMARQUE Lors de l utilisation d un syst me d vacuation existant nettoyer et liminer la charpie sur toute la longueur du syst me et veiller ce que le clapet d vacuation ne soit pas obstru par de la charpie Remplacer tout conduit de plastique ou en aluminium par un conduit m tallique rigide ou souple Consulter nouveau le Tableau des syst mes d vacuation et modifier le syst me d vacuation existant au besoin pour obtenir un meilleur s chage Coudes E Les coudes 45 permettent une meilleure circulation de l air que les coudes 90 Bon Mieux Brides de serrage M Utiliser des brides pour sceller tous les joints m Le conduit d vacuation ne doit pas tre raccord ou fix avec des vis ou tout autre d
72. par une unique pression sur un bouton Programme fixe avec tarif d appoint Une s cheuse r gl e pour proposer une fonctionnalit Top Off appoint permet d ajouter une dur e un programme de s chage existant par paliers gaux au nombre de minutes de dur e de s chage par pi ce de 0 25 pi ce 1 jusqu 99 minutes quel que soit le co t n cessaire pour mettre en marche la s cheuse Aucun cr dit n est accord pour les pi ces ins r es ou les apports par carte de d bit lorsque l affichage indique 99 minutes L incr ment Centime n est pas appliqu pour les achats de temps ajout PROGRAMMES GRATUITS Cette fonction est tablie en r glant le prix du programme sur z ro Dans ce cas SELECT CYCLE s lectionner programme s affiche la place du prix du programme Tout programme commenc comme programme gratuit prend fin automatiquement lors de l ouverture de la porte COMPATIBLE CARTE DE DEBIT Cette s cheuse est compatible pour avec les lecteurs de carte de d bit Il accepte divers syst mes de cartes de d bit mais est livr SANS lecteur de carte de d bit Consulter le fabricant du lecteur de carte de d bit pour une installation correcte avec la s cheuse Dans les mod les convertis en un syst me carte de d bit de 1e g n ration les impulsions de d bit repr sentent l quivalent d une pi ce pi ce 1 Affichage Une fois la s cheuse branch e et sa porte ouverte puis ferm e l
73. pr sente garantie limit e ne couvre pas 1 Tous autres frais y compris frais de main d oeuvre transport frais d exp dition ou droits de douane pour les pi ces couvertes 2 Les pi ces de rechange sp cifi es par l usine lorsque cet appareil m nager usage commercial est utilis des fins autres qu un usage commercial normal ou lorsque les instructions d installation et ou les instructions de l op rateur ou de l utilisateur fournies ne sont pas respect es 3 Les visites de service pour rectifier l installation de l appareil m nager usage commercial montrer l utilisateur comment utiliser l appareil m nager usage commercial remplacer ou r parer des fusibles ou rectifier le c blage ou la plomberie externe Les dommages imputables mauvaise manipulation du produit lors de la livraison vol accident modification usage impropre ou abusif incendie inondation catastrophes naturelles installation fautive ou non conforme aux codes locaux d lectricit ou de plomberie ou l utilisation de produits non approuv s par Maytag Le ramassage et la livraison Cet appareil m nager usage commercial est con u pour tre r par sur site Les r parations des pi ces ou syst mes r sultant d une modification non autoris e apport e l appareil m nager usage commercial L enl vement et la r installation de l appareil m nager usage commercial si celui ci est install dans un endroit inaccessible ou n est pas
74. presse permanente pour passer au code suivant 9 00 OPTION DE COMPTAGE DES PROGRAMMES Cette option est soit non s lectionn e OFF soit s lectionn e ON 9 00 Non s lectionn e OFF 90C S lectionn e ON ne peut pas tre d s lectionn e E Appuyer sur le bouton DELICATES articles d licats 3 fois de suite pour s lectionner ON Une fois l option ON s lectionn e elle est bloqu e cette valeur E Appuyer une fois sur le bouton PERM PRESS presse permanente pour passer au code suivant Si le compteur de programmes 9 OC est s lectionn le calcul du total est le suivant 200 25 1 00 CENTAINES de programmes 1 2 00 Programmes UNITAIRES 2 Ia IS NOMBRE TOTAL 225 Affichage seulement l effacement n est pas possible E Appuyer une fois sur le bouton PERM PRESS presse permanente pour passer au code suivant 50 Code Explication 1 00 OPTION DE COMPTAGE DE MONNAIE Cette option est soit non s lectionn e OFF soit s lectionn e ON 1 00 Non s lectionn e OFF 1 0C S lectionn e ON M Appuyer sur le bouton DELICATES articles d licats 3 fois de suite pour s lectionner ON puis 3 fois de suite pour retirer l option non s lectionn e OFF Le compteur se remet z ro en passant de l option OFF l option ON 1 CO S lectionn e ON ne peut pas tre d s lectionn e E Pour s lect
75. r un c ble de rallonge Le non respect de ces instructions peut causer un d c s un incendie ou un choc lectrique 5 Brancher sur une prise reli e la terre ou connecter la source de courant lectrique 45 INVERSION DU SENS D OUVERTURE DE LA PORTE FACULTATIF Le sens d ouverture de la porte peut tre chang du c t droit au c t gauche si d sir Retirer l assembl e de porte 1 Placer une serviette sur le dessus de la zone de travail pour prot ger la surface 2 Ouvrir la porte de la s cheuse Oter les vis inf rieures du c t charni re de la caisse Desserrer ne pas retirer les vis sup rieures du c t charni re de la caisse Bouchons d obturation 3 Soulever la porte jusqu ce que les vis sup rieures de la caisse se trouvent dans la partie large de l encoche de la charni re Tirer la porte vers l avant pour la d gager des vis Placer la porte c t poign e vers le haut sur la serviette Retirer les vis de la charni re sup rieure de la caisse 4 Retirer les vis fixant les charni res la porte 5 Retirer les vis de chaque c t de la porte 5 vis 6 Tout en maintenant la porte sur une serviette saisir les c t s de la porte externe et soulever doucement pour la s parer de la porte interne ne pas les s parer en for ant Ne pas tirer sur le joint ou le loquet en plastique de la porte 46 Loquet 7 Vei
76. r wire to center terminal Ground wire green or bare wire must be connected to green ground connector Connect remaining 2 supply wires to remaining 2 terminals gold Securely tighten all electrical connections Failure to do so can result in death fire or electrical shock If connecting by direct wire Direct wire cable must match power supply 4 wire or 3 wire and be E Cable must be rated to 60 Amps minimum Flexible armored cable or nonmetallic sheathed copper cable with ground wire covered with flexible metallic conduit All current carrying wires must be insulated M 6 gauge minimum solid copper wire do not use aluminum E Atleast 5 ft 1 52 m long 12 DRYER VENTING REQUIREMENTS WARNING Fire Hazard Use a heavy metal vent Do not use a plastic vent Do not use a metal foil vent Failure to follow these instructions can result in death or fire WARNING To reduce the risk of fire this dryer MUST BE EXHAUSTED OUTDOORS IMPORTANT Observe all governing codes and ordinances Dryer exhaust must not be connected into any gas vent chimney wall ceiling attic crawlspace or a concealed space of a building Only rigid or flexible metal vent shall be used for exhausting 4 102 mm 4 102 mm Heavy metal exhaust vent E Only a 4 102 mm heavy metal exhaust vent and clamps may be used Do not use plastic or metal foil vent Rigid metal vent E Recommende
77. rcial est install e entretenue et utilis conform ment aux instructions jointes ou fournies avec le produit Maytag marque de Whirlpool Corporation ci apr s d sign es Maytag paiera pour les pi ces de rechange sp cifi es par l usine pour corriger les vices de mat riaux ou de fabrication qui existaient d j lorsque cet appareil m nager usage commercial a t achet Cette garantie limit e n inclut pas frais de main d oeuvre LE SEUL ET EXCLUSIF RECOURS DU CLIENT DANS LE CADRE DE LA PR SENTE GARANTIE LIMIT E CONSISTE EN LA R PARATION PREVUE CI DESSUS Maytag recommande que l utilisateur emploie les services d une agence intra r seau pour diagnostiquer et r parer le produit de buanderie usage commercial concern Maytag ne sera pas responsable de l obtention de pi ces de rechange suppl mentaires dans le cadre de la pr sente garantie suite un diagnostic erron ou une r paration erron e effectu e par un service de d pannage hors r seau Cette garantie limit e est valide aux Etats Unis ou au Canada et s applique exclusivement lorsque l appareil m nager usage commercial concern est utilis dans le pays o il a t achet La pr sente garantie limit e est valable compter de la date d achat initial par le consommateur Une preuve de la date d achat d origine est exig e pour obtenir un d pannage dans le cadre de la pr sente garantie limit e L MENTS EXCLUS DE LA GARANTIE La
78. re distributeur et doit tre install sur la ligne d vacuation de chaque s cheuse pour viter que l air vacu revienne dans les s cheuses et pour maintenir l vacuation en quilibre avec le conduit de sortie principal Des ouvertures d gag es pour le retour d air sont n cessaires Chaque conduit doit p n trer dans le conduit principal en direction du mouvement de circulation de l air Les vacuations par l autre c t doivent tre plac es en quinconce d cal es pour r duire les interf rences avec l air sortant des autres vacuations en face lt S Pak lt S KEA L inclinaison maximale de chaque conduit qui p n tre dans le conduit principal ne doit pas d passer 30 Veiller ce que les ouvertures de passage d air demeurent exemptes de vapeurs de solvants de nettoyage sec Les vapeurs sont source de formation de compos s acides dont l introduction via les modules de chauffage de la s cheuse peut provoquer la d t rioration de la s cheuse et du linge en cours de s chage L ouverture principale comporte normalement un couvercle amovible ce qui permet le nettoyage p riodique du circuit d extraction RACCORDEMENT LA CANALISATION DE GAZ Raccordement la canalisation de gaz AVERTISSEMENT Risque du poids excessif Utiliser deux ou plus de personnes pour d placer et installer la s cheuse Le non respect de cette instruction peut causer une blessure au dos ou d autre blessure
79. reste une pi ce passer en revue les diff rentes tapes d termin e REMARQUE I faut que la porte soit ferm e pour que la s cheuse puisse fonctionner La s cheuse s arr te d s l ouverture de la porte mais la minuterie continue de fonctionner Pour remettre la s cheuse en marche fermer la porte et A AVERTISSEMENT res lectionner un programme 7 Ouvrir la porte de la s cheuse V rifier que l int rieur de la s cheuse est chaud Si le br leur ne s allume pas et qu on ne ressent pas de chaleur l int rieur de la s cheuse teindre la W s cheuse pendant cinq minutes V rifier que toutes les manettes 3 V rifier la pr sence de tous les outils 4 liminer recycler tous les mat riaux d emballage des vannes d alimentation sont en position ouverte ON et que le cordon lectrique est branch R p ter le test de 5 minutes d crit ci dessus Risque de choc lectrique 8 Si le temps de s chage est trop long s assurer que le filtre Brancher sur une prise 3 alv oles reli e la terre charpie est propre et v rifier qu il n y a aucun obstacle a au d bit d air du circuit d vacuation de la s cheuse Ne pas enlever la broche de liaison la terre 9 D marrer nouveau la s cheuse et la laisser ex cuter une Ne pas utiliser un adaptateur programme de s chage avec chaleur pas le programme de s chage l air pour v rifier qu elle fonctionne correctement Ne pas utilise
80. riginal consumer purchase Proof of original purchase date is required to obtain service under this limited warranty ITEMS EXCLUDED FROM WARRANTY This limited warranty does not cover 1 All other costs including labor transportation shipping or custom duties for covered parts 2 Factory specified replacement parts if this commercial appliance is used for other than normal commercial use or when it is used in a manner that is inconsistent to published user or operator instructions and or installation instructions 3 Service calls to correct the installation of your commercial appliance to instruct you on how to use your commercial appliance to replace or repair house fuses or to correct external wiring or plumbing 4 Damage resulting from improper handling of product during delivery theft accident alteration misuse abuse fire flood acts of God improper installation installation not in accordance with local electrical or plumbing codes or use of products not approved by Maytag 5 Pick up and delivery This commercial appliance is designed to be repaired on location 6 Repairs to parts or systems resulting from unauthorized modifications made to the commercial appliance 7 The removal and reinstallation of your commercial appliance if it is installed in an inaccessible location or is not installed in accordance with published installation instructions 8 Damage resulting from exposure to chemicals Changes to the building
81. rve all governing codes and ordinances E Check code requirements Some codes limit or do not permit installation of clothes dryers in garages closets or sleeping quarters Contact your local building inspector E Make sure that lower edges of the cabinet plus the back and bottom sides of the dryer are free of obstructions to permit adequate clearance of air openings for combustion air See Recessed Area Installation Instructions below for minimum spacing requirements Recessed Area Installation Instructions This dryer may be installed in a recessed area For recessed area installations minimum clearances can be found on the warning label on the rear of the dryer or in Dimensions Clearances The installation spacing is in inches and is the minimum allowable Additional spacing should be considered for ease of installation servicing and compliance with local codes and ordinances The dryer must be exhausted outdoors GAS DRYER ELECTRICAL REQUIREMENTS WARNING 4 Electrical Shock Hazard Plug into a grounded 3 prong outlet Do not remove ground prong Do not use an adapter Do not use an extension cord Failure to follow these instructions can result in death fire or electrical shock IMPORTANT The dryer must be electrically grounded in accordance with local codes and ordinances or in the absence of local codes with the National Electrical Code ANSI NFPA 70 latest edition or Canadian
82. s localiser un revendeur le centre d aide pour les appareils de buanderie usage commercial r pond toute question qui n aurait pas t abord e dans les Instructions d installation au sujet du fonctionnement ou de l entretien de la s cheuse Il suffit de composer le 1 800 NO BELTS 1 800 662 3587 l appel est gratuit Lors de votre appel vous aurez besoin du num ro de mod le et de s rie de la s cheuse Ces deux num ros figurent sur la plaque signal tique situ e dans l encadrement de la porte de la s cheuse 47 INSTRUCTIONS DE R GLAGE DU TABLEAU DE COMMANDE LECTRONIQUE IMPORTANT Circuits lectroniques sensibles aux d charges lectrostatiques Le risque de d charge lectrostatique est permanent Une d charge lectrostatique peut d truire ou d t riorer les circuits lectroniques de la s cheuse La nouvelle carte peut sembler fonctionner correctement apr s la r paration mais une d charge lectrostatique peut lui avoir fait subir des contraintes qui provoqueront une d faillance plus tard E Utiliser un bracelet de d charge lectrostatique Connecter le bracelet de d charge lectrostatique au point de connexion vert reli la terre ou sur une partie de m tal non peint l int rieur de l appareil OU Toucher plusieurs fois de suite avec le doigt un point vert de raccordement la terre ou une surface m tallique non peinte l int rieur de l appareil M Avant de re
83. s curit et le mot DANGER ou AVERTISSEMENT Ces mots signifient Risque possible de d c s ou de blessure grave si vous ne A DANG E R suivez pas imm diatement les instructions Risque possible de d c s ou de blessure grave si vous A AVE RTISSE M ENT ne suivez pas les instructions Tous les messages de s curit vous diront quel est le danger potentiel et vous disent comment r duire le risque de blessure et ce qui peut se produire en cas de non respect des instructions A AVERTISSEMENT Risque d incendie L installation de la s cheuse linge doit tre effectu e par un installateur qualifi Installer la s cheuse conform ment aux instructions du fabricant et aux codes locaux Ne pas installer de s cheuse linge avec des mat riaux d vacuation en plastique souple ou un conduit m tallique souple de type papier d aluminium Si un conduit m tallique souple est install celui ci doit tre d un type sp cifique identifi par le fabricant de l appareil et convenir une utilisation avec les s cheuses linge Les mat riaux d vacuation souples sont connus pour s affaisser tre facilement cras s et bloquer la charpie Ces situations obstrueront le d bit d air de la s cheuse linge et augmenteront le risque d incendie Pour r duire le risque de blessure grave ou de d c s suivre toutes les instructions d installation Conserver ces instructions E On recomma
84. s de la caisse ainsi que les c t s arri re et inf rieurs de la s cheuse sont bien d gag s pour permettre une vacuation ad quate de l air de combustion Voir la section Instructions d installation dans un encastrement ci dessous pour conna tre les distances de d gagement minimales Instructions d installation dans un encastrement Cette s cheuse peut tre install e dans un encastrement Pour les installations dans un encastrement les distances de d gagement minimales sont indiqu es sur l tiquette d avertissement l arri re de la s cheuse ou la section Dimensions Distances de d gagement Les dimensions d installation sont en pouces et constituent le minimum applicable Un espace suppl mentaire peut tre n cessaire pour faciliter l installation l entretien et pour observer les codes et r glements locaux La s cheuse doit tre vacu e l ext rieur EXIGENCES LECTRIQUES POUR LA S CHEUSE GAZ AVERTISSEMENT y Risque de choc lectrique Brancher sur une prise 3 alv oles reli e la terre Ne pas enlever la broche de liaison la terre Ne pas utiliser un adaptateur Ne pas utiliser un c ble de rallonge Le non respect de ces instructions peut causer un d c s un incendie ou un choc lectrique IMPORTANT La s cheuse doit tre reli e la terre conform ment aux codes et r glements locaux en vigueur ou en l absence de tels codes avec la derni re d
85. s lors de l utilisation de la s cheuse suivre les pr cautions fondamentales dont les suivantes Lire toutes les instructions avant d utiliser la s cheuse Cette s cheuse est con ue uniquement pour le s chage de v tements et de textiles ayant t nettoy s l eau Ne pas l utiliser toute autre fin AVERTISSEMENT Si l on d tecte une odeur de gaz ne pas utiliser la s cheuse ou tout autre quipement lectrique situ proximit Avertir les autres personnes qu elles doivent vacuer cette zone Contacter le propri taire de la s cheuse imm diatement Ne pas placer des articles expos s aux huiles de cuisson dans votre s cheuse Les articles contamin s par des huiles de cuisson peuvent contribuer une r action chimique qui pourrait causer la charge de s enflammer Ne pas faire s cher des articles qui ont t nettoy s ou lav s avec de l essence ou imbib s d essence solvants de nettoyage sec ou autres substances inflammables ou explosives ces substances peuvent mettre des vapeurs susceptibles de s enflammer ou d exploser Ne pas faire s cher dans la s cheuse des articles nonlav s Ne pas laisser des enfants jouer sur ou l int rieur de la s cheuse Bien surveiller les enfants lorsque la s cheuse est utilis e proximit d enfants Avant de retirer la s cheuse pour un d pannage ou pour le jeter ter les portes des compartiments de la s cheuse Ne pas tenter d atteindre un
86. sign certified by CSA International for LP propane and butane gases with appropriate conversion No attempt shall be made to convert dryer from gas specified on serial rating plate for use with a different gas without consulting the serving gas supplier Conversion must be done by a qualified service technician Gas conversion kit part numbers are listed on gas valve burner base Gas Supply Line Recommended Method Provide a gas supply line of 1 2 13 mm rigid IPS pipe to dryer location Pipe joint compounds that resist action of LP gas must be used Do not use TEFLON tape With LP gas piping or tubing size can be 1 2 13 mm minimum Usually LP gas suppliers determine size and materials used in the system Gas Supply Pressure Testing A 1 8 NPT minimum plugged tapping accessible for gauge testing must be installed immediately downstream of the installed shut off valve to the dryer as shown above The dryer must be disconnected from the gas supply piping system during any pressure testing of the system at test pressures in excess of 1 2 psig 352 kg m Alternate Method The gas supply may also be connected using 3 8 10 mm approved copper or aluminum tubing If the total length of the supply line is more than 20 ft 6 1 m larger tubing will be required If using natural gas do not use copper tubing Pipe joint compounds that resist action of type of gas supplied must be used Shut off valve required
87. sition Do not crush or kink vent Make sure dryer is level DRYER VENTING REQUIREMENTS If an Exhaust Hood Cannot be Used The outside end of main vent should have a sweep elbow directed downward A 24 min 12 min 610 mm 305 mm p a Minimum clearance above any accumulation of snow ice or debris such as leaves p ai If main vent travels vertically through the roof rather than through wall install a 180 sweep elbow on end of vent at least 2 ft 610 mm above surface of roof The opening in wall or roof shall have a diameter 1 2 13 mm larger than vent diameter Vent should be centered in opening Do not install screening over end of vent for best performance Multiple Dryer Venting A main vent can be used for venting a group of dryers The main vent should be sized to remove 5663 l min 200 CFM of air per dryer Large capacity lint screens of proper design may be used in main vent if checked and cleaned frequently The room where the dryers are located should have make up air equal to or greater than CFM of all the dryers in the room Back draft Damper Kit Part No 3391910 is available from your distributor and should be installed in the vent of each dryer to keep exhausted air from returning into dryers and to keep exhaust in balance within main vent Unobstructed return air openings are required Each vent should enter the main vent at an angle pointing in the direction of the a
88. stic code is manually cleared Upper dryer motor control circuit error upper dryer cycles and upper dryer display disabled until diagnostic code is manually cleared 29 MAYTAG COMMERCIAL WASHER DRYER STACKED DRYER DRYER COMMERCIAL STACK LAUNDRY AND MULTI LOAD COIN OPERATED COMMERCIAL WASHERS AND DRYERS WARRANTY LIMITED WARRANTY PARTS ONLY LABOR NOT INCLUDED For the first five years from the original date of purchase when this commercial appliance is installed maintained and operated according to the instructions attached to or furnished with the product Maytag brand of Whirlpool Corporation hereafter Maytag will pay for factory specified replacement parts to correct defects in materials or workmanship that existed when this commercial appliance was purchased This limited warranty does not include labor YOUR SOLE AND EXCLUSIVE REMEDY UNDER THIS LIMITED WARRANTY SHALL BE PRODUCT REPAIR AS PROVIDED HEREIN Maytag recommends that you use an in network service provider to diagnose and repair your Commercial Laundry product Maytag will not be responsible under this warranty to provide additional replacement parts as a result of incorrect diagnosis or repair by an out of network service company This limited warranty is valid in the United States or Canada and applies only when the commercial appliance is used in the country in which it was purchased This limited warranty is effective from the date of the o
89. than the dollars and cents amount The number in the display changes as the coins are accepted Not Selected OFF Selected ON E Press the DELICATES button 3 consecutive times to change this selection E Press the PERM PRESS button once to advance to next code Code J Cd J Cd J C Jd J Ed L 00 L 00 L PS n CE n 00 n CE ELECTRONIC CONTROL SETUP INSTRUCTIONS Explanation PAYMENT MODE COIN DEBIT OPTION Both coin and debit selected Press the DELICATES button 3 consecutive times to change this selection Coins selected debit disabled Press the DELICATES button 3 consecutive times to change this selection Debit Card selected coins disabled Press the DELICATES button 3 consecutive times to change this selection Enhanced Debit is self selected when a Generation 2 card reader is installed in the dryer The Ed option cannot be manually selected or deselected E Press the PERM PRESS button once to advance to next code PRICE SUPPRESSION OPTION This option is either NOT SELECTED OFF or SELECTED ON This option causes the customer display to show ADD or AVAILABLE rather than the amount of money to add Used mainly in debit installations Not Selected OFF Selected ON E Press the DELICATES button once to change this selection E Press the PERM PRESS button once to advance to next code CLEAR ESCROW OPTION This option is either NOT SELECTED
90. the money and or cycle counts will be viewable if counter option s is selected when the coin box is removed E Press the PERM PRESS button once to advance to next code Code b 05 b 05 C 20 C 20 d 00 d 00 d CS E 00 E 00 E AC Explanation VALUE OF COIN 1 This represents the value of coin 1 in number of nickels 05 0 25 E By pressing the WHITES AND COLORS button there is an option of 1 199 nickels E Press the PERM PRESS button once to advance to next code VALUE OF COIN 2 This represents the value of coin 2 in number of nickels 20 1 00 E By pressing the WHITES AND COLORS button there is an option of 1 199 nickels E Press the PERM PRESS button once to advance to next code COIN SLIDE OPTION This option is either NOT SELECTED OFF or SELECTED ON Not Selected OFF Selected ON E Press the DELICATES button 3 consecutive times for this selection When coin slide mode is selected set b equal to value of slide in nickels Set 606 REGULAR CYCLE PRICE and 3 06 SPECIAL CYCLE PRICE to number of slide operations NOTE If the installer sets up CS on a coin drop model it will not register coins E Press the PERM PRESS button once to advance to next code ADD COINS OPTION This option is either NOT SELECTED OFF or SELECTED ON This option causes the customer display to show the number of coins coin 1 to enter rather
91. tirer la pi ce de son emballage placer le sachet antistatique en contact avec un point vert de raccordement la terre ou une surface m tallique non peinte l int rieur de l appareil viter de toucher les composants lectroniques ou les broches de contact manipuler les circuits lectroniques de la machine uniquement par les bords Lors du r emballage des circuits lectroniques de la s cheuse d faillante dans le sachet antistatique observer les instructions ci dessus Informations g n rales d utilisation AFFICHAGE VIDE Cette situation indique que la s cheuse ne fonctionne pas Entrer au mode de r glage pour consulter le code de diagnostic 0 MINUTES INDIQUE SUR LAFFICHAGE Cette mention indique que le programme est termin et que la s cheuse ne peut pas tre remise en marche Les pi ces introduites ou le d bit par carte engag pendant cette phase sont stock es en avoir mais ne sont pas utilisables tant que le fonctionnement normal n est pas r tabli par l ouverture et la fermeture de la porte En cas de d faillance du contacteur d une porte le contacteur doit tre remplac avant le r tablissement d un fonctionnement normal D MARRAGE FROID premi re utilisation La s cheuse est programm en usine de la mani re suivante Dur e de s chage de 5 minutes pi ce de 25 cents pi ce 1 Prix du s chage 1 50 programme fixe avec dur e suppl mentaire D MARRAGE CHAUD
92. upon the type of vent used number of elbows and type of exhaust hood Vent System Chart Rigid Metal Vent Box and Louvered Hood No of 90 Turns 0 130 ft 39 6 m 125 ft 38 1 m 115 ft 35 1 m 106 ft 32 3 m 98 ft 29 9 m Angled Hood 129 ft 39 3 m 119 ft 36 3 m 109 ft 33 2 m 100 ft 30 5 m 92 ft 28 m A N For vent systems not covered by the vent specification chart see your parts distributor Provision must be made for enough air for combustion and ventilation Check governing codes and ordinances See Recessed Area Installation Instructions in the Location Requirements sections A 4 102 mm outlet hood is preferred However a 2 64 mm outlet exhaust hood may be used A 212 64 mm outlet creates greater back pressure than other hood types For permanent installation a stationary vent system is required Connect Vent 1 If connecting to existing vent make sure the vent is clean 2 Using a 4 102 mm clamp connect vent to exhaust outlet in dryer Vent collar Ach Set NOTE Do not remove vent collar 14 Exhaust hood must be at least 12 305 mm from the ground or any object that may be in the path of the exhaust such as flowers rocks bushes or snow 12 min 3 Tighten hose clamp with Phillips screwdriver 4 Make sure the vent is secured to exhaust hood with a 4 102 mm clamp 5 Move dryer into final po
93. y cord where local codes do not permit connecting cabinet ground conductor to neutral wire Connecting Neutral Wire 1 Remove center terminal block screw Also remove neutral 3 Connect remaining wires to outer terminal block ground wire by removing external ground conductor screw ES ES Er T SE BAr TNI eo k 2 Connect neutral wire and neutral wire of power supply cord 4 Connect a separate copper ground wire from the external cable to center terminal block ground conductor to an adequate ground EEE ale e WI 4 wy UT f LEVELING Leveling your dryer properly reduces excess noise and vibration Excessive Weight Hazard Use two or more people to move and install dryer Failure to do so can result in back or other injury Not Level LEVEL Not Level 1 Remove cardboard from beneath dryer Place a level on top edges of dryer checking each side and front If not level tip dryer and adjust legs up or down as shown in Steps 3 and 4 repeating as necessary 21 LEVELING 2 Grip dryer from top and rock back and forth making sure all four legs are firmly on floor Repeat rocking dryer from side to side If dryer rocks go to Step 3 and adjust leveling legs If all four legs are in firm contact with floor go to Step 4 ts i 3 If dryer is not level use a 1 or 25 mm open end or adjustable wrench to turn jam nuts clockwise
94. ycle with top off WARM START after power failure A few seconds after power is restored if a cycle was in progress at the time of the power failure RESELECT CYCLE will flash in the display indicating a button needs to be pressed to restart dryer PRICING After the door is opened and then closed following the completion of a cycle the display indicates the cycle price unless set for free operation As coins are dropped or debit inputs arrive the display will change to lead the user through the initiation of a cycle There are four 4 types of dryer pricing Fixed Vend Pricing A dryer set up for Fixed Cycle operation can only accept additional time accumulated by increments equal to the length of a complete dry cycle A maximum of 99 minutes may be purchased no additional credit is given for coins dropped with 99 minutes in the display Accumulator Pricing If the price is set to one coin 1 then accumulator pricing is in effect Fixed Cycle with Top Off option must also be selected Cycle time can be purchased one coin at a time up to the maximum time of 99 minutes All money will be credited to a cycle with a single button press while in accumulator pricing Fixed Cycle With Top Off Pricing A dryer set to offer Top Off capability will allow time to be added to an existing dry cycle in increments equal to the number of minutes of dry time per quarter coin 1 up to 99 minutes reg