Home
! WARNING - Napoleon Products
Contents
1. DU LOGO W415 1464 04 22 15 67 7 0 FAITES TOUJOURS APPAREIL AVEC LA PORTE VERROUILLEE SAUF DURANT L ALLUMAGE ET LE RAVITAILLEMENT PORTEZ TOUJOURS DES GANTS POUR PREVENIR LES BLESSURES LAISSEZ PAS L APPAREIL SANS SUPERVISION LORSQUE LES PORTES SONT D VERROUILL ES DU BOIS INSTABLE POURRAIT TOMBER HORS DE LA CHAMBRE DE COMBUSTION ET CR ER UN RISQUE D INCENDIE LAISSEZ JAMAIS LES ENFANTS SANS SURVEILLANCE LORSQU UN FEU BRULE DANS L APPAREIL N UTILISEZ JAMAIS D ESSENCE DE COMBUSTIBLE LANTERNE DE K ROS NE D ESSENCE BRIQUET O D AUTRES LIQUIDES POUR ALLUMER O RAVIVER UN FEU DANS CET APPAREIL GARDEZ TOUS CES LIQUIDES ELOIGNES DE L APPAREIL LORSQUE CELUI CI FONCTIONNE LES OBJETS PLAC S DEVANT L APPAREIL DOIVENT TRE GARD S UNE DISTANCE D AU MOINS 48 1219 2mm DE LA FACE VITR E TOUTE MODIFICATION APPORT E L APPAREIL QUI N A PAS T PR ALABLEMENT APPROUV E PAR CRIT PAR LE LABORATOIRE D ESSAI EST CONSID R COMME UNE VIOLATION DES NORMES CSA B365 CANADA ET ANSI NFPA 211 U OUVREZ LE CONTR LE DE COMBUSTION ET LE REGISTRE S IL Y A LIEU AVANT D OUVRIR LA PORTE DE L APPAREIL L APPAREIL EST CHAUD LORSQU IL FONCTIONNE TENIR LES ENFANTS LES V TEMENTS ET LES MEUBLES L CART LE CONTACT PEUT CAUSER DES BR LURES PORTEZ DES GANTS LORSQUE VOUS OP REZ VOT
2. OU PLUS 3 PI 1m 3 PI 1m MIN _ EX FA TOIT PLAT MUR 59 1B Une chemin e isol e en acier inoxydable doit tre support e au plafond ou au toit et son installation doit tre conforme aux instructions de son fabricant 415 1464 04 22 15 4 1 3 TYPIQUE TRAVERS PLAFOND Mettez l appareil en place le centre de la buse de fa on ne pas avoir couper les solives Utilisez un fil plomb pour aligner le centre de la buse B D coupez et charpentez une ouverture dans le plafond de fa on fournir un d gagement de 2 50 8mm entre la chemin e et les mat riaux combustibles Ne remplissez cet espace avec aucun type de mat riau Fixez des entretoises entre les solives pour assurer un support additionnel Pour tout plancher ou plafond travers s par la chemin e des espaceurs coupe feu doivent tre fix s la base de chaque ouverture charpen t e Si la chemin e traverse le grenier un cran de protection pour chevrons est ECT requis LT 1 2l ESPACEUR COUPE FEU C Tenez un fila plomb a partir du dessous FACE INFERIEURE DES du toit pour determiner ou doit se trouver SOLIVES l ouverture du toit D coupez et charpen tez une ouverture dans le toit tout en conservant le d gagement de 2 50 8mm NOTE La chemin e doit tre support e au plafond ou au toit afin que son
3. EP21LA S ILLUSTRATED ASH LIP INSTALLATION 23 To avoid damage during transport the ash lip has been shipped in the firebox Using the two screws that secured the appliance to the shipping bracket attach the ash lip as illustrated W415 1464 04 21 15 24 6 0 OPTIONAL INSTALLATION 6 1 BLOWER KIT INSTALLATION RISK OF FIRE AND ELECTRICAL SHOCK TURN OFF THE GAS AND ELECTRICAL POWER BEFORE SERVICING THIS APPLIANCE USE ONLY WOLF STEEL APPROVED OPTIONAL ACCESSORIES AND REPLACEMENT PARTS WITH THIS APPLIANCE USING NON LISTED ACCESSORIES BLOWERS DOORS LOUVRES TRIMS GAS COMPONENTS VENTING COMPONENTS ETC COULD RESULT IN A SAFETY HAZARD AND WILL VOID THE WARRANTY AND CERTIFICATION ENSURE THAT THE FAN S POWER CORD IS NOT IN CONTACT WITH ANY SURFACE OF THE APPLIANCE TO PREVENT ELECTRICAL SHOCK OR FIRE DAMAGE DO NOT RUN THE POWER CORD BENEATH THE APPLIANCE THE WIRE HARNESS PROVIDED IN THE BLOWER KIT IS A UNIVERSAL HARNESS WHEN INSTALLED ENSURE THAT ANY EXCESS WIRE IS CONTAINED PREVENTING IT FROM MAKING CONTACT WITH MOVING OR HOT OBJECTS D bearings causing irreparable damage C dust from coming into contact with the blower or its compartment Any damage resulting from this condition is not cov ered by the warranty policy Use of the blower increases the output of heat P rywall dust will penetrate into the blower are must be taken to prevent drywall rovisions have b
4. 2 1 1 5 Twn niceser 415 1464 04 21 15 O TY lt 38 10 00 TROUBLESHOOTING TURN OFF THE ELECTRICAL POWER SERVICING THE APPLIANCE WHEN CHECKING CONNECTIONS INSTALLING JUMPER WIRES FOR TEST PURPOSES ONLY OR REPLACING COMPONENTS UNPLUG HEATER FROM THE RECEPTACLE TO PREVENT ELECTRICAL SHOCK OR DAMAGE TO THE COMPONENT PROBLEM SOLUTION Can t get the fire started Not enough kindling paper Add more Not enough air Ensure air control is fully open Also ensure that the air opening is not obstructed Cold air blockage Burn a piece of paper to establish a draft Use dry seasoned wood with 20 moisture content Flue blockage Inspect chimney Smokes when door is Cold air blockage Burn a piece of paper to establish a draft open Insufficient draft Add more pipe Let air stabilize before opening door Ensure baffles are positioned correctly Negative pressure Open a window near the appliance Appliance emits odour Paint curing See GENERAL INSTRUCTIONS section Stove doesn t burn hot Wood has more than 20 moisture enough Insufficient draft Add more pipe Not enough air Ensure air control is fully open Also ensure that the air opening is not obstructed Wood burns too f
5. CONDUIT DE RACCORDEMENT MUR BASE DE COMBUSTIBLE PROTECTION 61 1 415 1464 04 22 15 of 4 1 5 INSTALLATION TYPIQUE DANS UNE CHEMIN E DE MACONNERIE EXISTANTE Vous pouvez aussi installer votre appareil en utilisant votre chemin e de ma onnerie existante rr Pour ce faire suivez les directives suivantes Nous vous conseillons d installer un coupe feu RL I pr fabriqu ou d en construire un Si vous ns H utilisez une chemin e en ma onnerie vous T devez vous assurer qu elle r ponde aux CHEVRON L normes de construction de votre r gion CH AVANT TOIT FR D GAGEMENT AVEC UN COUPE FEU Elle doit tre construite de briques d argile r fractaire de tuiles de m tal ou d argile T I T ciment s ensemble avec du ciment A r fractaire Les conduits de chemin e SOLIVE DE PLAFOND LH r D GAGEMENT ronds sont les plus efficaces La maximum I du conduit carr 8 203 2mm 8 MUR COMBUSTIBLE 4 203 2mm ou 6 152 4mm pour une conduit circulaire RACCORDEMENT CONDUIT DE f EE BASE DE Lt PROTECTION l Lb MI HH HH E a 62 1 415 1464 04 22 15 58 5 0 FINISHING 5 1 INSTALLATION DES PATTES LA PLAQUE DOIT PAS TRE ENLEV E SAUF LORSQUE VO
6. iD TERMINAISON poids ne repose pas sur l appareil et son installation doit tre conforme aux instructions de son fabricant COLLET DE SOLIN SOLIN DE TOIT TOIT CONSERVER 27 e DE D GAGEMENT HOMOLOGU E am W V JPPORT d CONDUIT p LE PO LE 5 D TAIL DU RACCOR DEMENT CONDUIT DE RACCORDEMENT gu BASE DE EN MUR PROTECTION COMBUSTIBLE 60 1B 415 1464 04 22 15 56 4 1 4 INSTALLATION TYPIQUE TRAVERS UN MUR Si possible l installation des conduits de raccordement ne doit pas passer travers un mur combustible S faut absolument passer travers un mur combustible consultez votre inspecteur en b timent avant de proc der Consultez aussi le fabricant des conduits de raccordement pour connaitre toutes les exigences particuli res Consultez votre d taillant pour obtenir les composants de raccordement muraux dont vous auriez besoin N utilisez que les pi ces qui ont t test es et certifi es pour des installations travers un mur TERMINAISON CONSERVER UN TOIT D GAGEMENT DE 2 50 8 TRAVERS L AVANT TOIT CHIMINEE MUR EXTERIEUR HOMOLOGUEE COMBUSTIBLE COLLET DE SOLIN SOLIN DE TOIT CONDUIT DE RACCORDEMENT RACCORD EN T ISOLE SUPPORT ESPACEUR MURAL OU MUR EXTERIEUR COUPE FEU
7. the attic area a rafter radiation shield is required CL nm C Hold a plumb bob from the underside of the roof to determine where the opening the roof should be Cut and frame the roof opening to maintain proper 2 50 8mm clearances NOTE The chimney must be supported at the ceiling or roof so that it s weight does not rest on the appliance and must comply with it s ZA SZ HEADERS UNDERSIDE OF JOIST ERMINAL manufacturer s instructions MAINTAIN sten 2 50 8 STORM CLEARANCE COLLAR LISTED C9 H FLASHING Ts ROOF DERE CHIMNEY SUPPORT STOVE FLOOR PROTECTOR CONNECTOR INSULATION COMBUSTIBLE WALL gt lt H4 TE lt 60 1B W415 1464 04 21 15 16 4 1 4 TYPICAL THROUGH THE WALL If possible design the installation so that the connector does not pass through a combustible wall during your installation you must pass through a combustible wall check with your building inspector before you begin Also check with the chimney connector manufacturer for any specific requirements Consult with your dealer regarding special connection components available for use for wall pass throughs Use only parts that have been tested and listed for use in a wall pass through MAINTAIN 2 COMBUSTIBLE STORM OUTSIDE WALL COLLAR SECTION LISTED CHIMNEY PIPE COMBUSTIBLE C
8. DE CHOC LECTRIQUE COUPEZ L ALIMENTATION LECTRIQUE AVANT DE PROC DER L ENTRETIEN DE L APPAREIL N UTILISEZ QUE LES ACCESSOIRES OPTIONNELS ET LES PIECES DE RECHANGE APPROUVES PAR WOLF STEEL POUR CET APPAREIL L UTILISATION D ACCESSOIRES NON LISTES SOUFFLERIE PORTES PERSIENNES MOULURES ETC POURRAIT TRE NON S CURITAIRE ET ANNULERA LA GARANTIE ET LA CERTIFICATION AFIN DE PR VENIR LES CHOCS LECTRIQUES ET LES DOMMAGES CAUS S PAR LE FEU ASSUREZ VOUS QUE LE CORDON D ALIMENTATION DE LA SOUFFLERIE N ENTRE PAS EN CONTACT AVEC QUELCONQUE SURFACE DE L APPAREIL NE FAITES PAS PASSER LE CORDON D ALIMENTATION SOUS L APPAREIL La poussi re de gypse p n trera dans le roulement billes de la soufflerie causant SUPPORT DE des dommages irr parables Vous devez viter que cette poussi re n entre contact avec la soufflerie ou son compar timent Tout dommage caus par ce pro bl me ne sera pas couvert par la garan tie L utilisation de la soufflerie accroit le d bit de chaleur Le support de l interrupteur thermique doit tre positionn comme illustr l est possible d installer une soufflerie optionnelle EP65 avec un interrupteur vitesse variable servant faire partir et arr ter la soufflerie ainsi qu contr ler sa vitesse A Assurez vous que le support de l interrupteur thermique est bien plac B Enlevez la plaque de l arri re de l appareil C Installez
9. pedestal Do not pivot appliance up as it could result in damage to the pedestal DOOR REMOVAL BURNING YOUR APPLIANCE WITH THE DOORS OPEN OR AJAR CREATES A FIRE HAZARD THAT MAY RESULT IN A HOUSE AND OR CHIMNEY FIRE DO NOT STRIKE OR SLAM DOOR NEVER REMOVE THE DOOR WHEN THE APPLIANCE IS HOT Pivot the door open and lift the door and pins off the bushings Set the door aside being careful not to scratch the paint W415 1464 04 21 15 20 5 4 DOOR HANDLE INSTALLATION BURNING YOUR APPLIANCE WITH THE DOORS OPEN OR AJAR CREATES A FIRE HAZARD THAT MAY RESULT IN A HOUSE AND OR CHIMNEY FIRE DO NOT STRIKE OR SLAM DOOR NEVER REMOVE THE DOOR WHEN THE APPLIANCE IS HOT NOTE DOOR MAY NOT BE AS ILLUSTRATED FRONT VIEW DOOR DOOR HANDLE LATCH LOCK WASHER NUT DOOR SPRING SPACER HANDLE WASHER 98 1 W415 1464 04 21 15 3 3 SECONDARY AIR TUBES A Start at the back working forwards by sliding the secondary air tube in the firebox and inserting the tube into the hole as illustrated in A B Slide the tube into the opposite hole With the holes on the secondary air tube pointing forward align the tube with the tube retainer and insert the cotter pin as illustrated in B C Spread the cotter pin to retain 21 NOTE On the 22 5 model there 4 secondary air tubes One of the tubes has larger holes This tube is to be located closest to the front of the appliance as
10. POUR REPARER CES DOMMAGES VOUS DEVREZ REMPLACER LES COMPOSANTS ENDOMMAGES LES FEUX DE CHEMINEE NE SONT PAS COUVERTS PAR LA GARANTIE A VIE LIMIT E Des feux hors contr le peuvent tre caus s par les trois facteurs suivants e L utilisation d un combustible inappropri ou de morceaux de bois trop petits qui normalement auraient t utilis s comme bois d allumage e Une porte laiss e entrouverte trop longtemps cr ant des temp ratures extr mes lorsque l air est entra n pr cipitamment par la porte ouverte e Faire fonctionner l appareil avec le couvercle de la chute cendres mal install ideis de Ne br lez pas de bois trait ou transform de charbon de charbon de bois de papier de couleur ou de carton e Faites attention de pas surchauffer l appareil en laissant la porte ouverte trop longtemps apres l allumage initial Un thermom tre sur le conduit de raccordement ou sur le dessus de l appareil serait utile e Faites toujours fonctionner l appareil avec le couvercle de chute cendres bien install ED CAS DE FEU DE CHEMIN E Ayez un plan d vacuation bien compris de tous et d signez un lieu de rassemblement l ext rieur Pr parez vous vacuer les lieux pour assurer la s curit de chacun e Fermez la prise d air de l appareil e Appelez votre service d incendie Ayez un extincteur sous la main Contactez les autorit s locales pour savoir quoi faire en cas de feu de chemin e e Apr s q
11. bris sur le dessus de l appareil avant de l allumer car la peinture ramolirra pendant que l appareil se r chauffe et durcira pendant le processus de cuisson Pour cuire la peinture faites br ler l appareil feu mod r durant les quelques premiers allumages e Pour emp cher le joint d tanch it de coller l appareil lors de la cuisson de la peinture ouvrez la porte de l appareil toutes les 5 10 minutes e Durant les deux premi res semaines faites br ler l appareil avec beaucoup de bois et ouvrez le contr le de combustion au maximum pendant une heure pour permettre l appareil d liminer toute humidit dans l acier et les briques r fractaires La production de chaleur initiale sera r duite alors que l humidit est chass e de l appareil sera n cessaire de faire plusieurs feux chauds pour liminer cette humidit LORS DE CE PROCESSUS NE SURCHAUFFEZ PAS L APPAREIL R DUISEZ L APPORT D AIR L APPAREIL SI CELUI CI OU LA CHEMIN E DEVIENNENT ROUGEOYANTS 415 1464 04 22 15 2 5 2 4 INSTRUCTIONS G N RALES La conception des mod les EP21LA S et EP22PA S est semblable et ils utilisent les m mes principes de combustion gt PARCOURS DES GAZ DE COMBUSTION PARCOURS DE L AIR COMBURANT lls ont t con us sur plusieurs mois de recherches afin de r pondre sp cifiquement aux exigences des normes d missions de particules de l E P A am ricaine de 1990 et o
12. cet effet voir la d a section TIROIR CENDRES OPTIONNEL L EMPLACEMENT DU LOGO 5 1464 04 22 15 5 2 INSTALLATION DU PI DESTAL NOTE Si vous installez le tiroir cendres optionnel assurez vous que le c t ouvert du pi destal se retrouve l avant de l appareil Sinon l ouverture devrait tre l arri re Pour viter que l appareil soit endommag lors du transport il a t boulonn la palette et doit tre d boulonn de celle ci avant d tre install A l aide des vis m tal fournies fixez le pi destal aux quatre supports situ s sous la chambre de combustion B Soulevez l appareil et d posez le doucement sur son pi destal Ne faites pas pivoter l appareil sur son pi destal car ceci risque de l endommager EMPLACEMENT DU LOGO 5 3 ENLEVEMENT DE LA PORTE FAIRE FONCTIONNER CET APPAREIL AVEC LES PORTES OUVERTES OU ENTROUVERTES CR E UN RISQUE D INCENDIE DE CHEMIN E OU DU DOMICILE NE FRAPPEZ PAS ET NE CLAQUEZ PAS LA PORTE N ENLEVEZ JAMAIS LA PORTE LORSQUE L APPAREIL EST CHAUD Ouvrez la porte et soulevez la en d gageant les tiges hors des ba gues Mettez la porte de c t en prenant soin de ne pas gratigner la peinture D GAGER LES BAGUES 415 1464 04 22 15 60 5 4 INSTALLATION DE LA POIGN E DE PORTE FAIRE FONCTIONNER CET APPAREIL AVEC LES PORTES OUVERTES ENTROUVERTES UN RISQUE D INCE
13. ouvert Assurez vous que le contr le d air n est pas obstru e Le bois br le trop Le contr le d air doit possiblement tre r duit rapidement Assurez vous que le couvercle de la chute cendres est bien install s il en est muni V rifiez que le joint d tanch it de la porte est bien herm tique Le bois est peut tre extr mement sec avec de 20 d humidit Vitre sale contr le d air peut tre trop ferm Faites des feux plus chauds et plus petits Utilisez du bois bien sec La soufflerie ne L appareil n a peut tre pas atteint sa temp rature fonctionne pas Assurez vous que la soufflerie est bien branch e 42 14C 415 1464 04 22 15 79 11 0 GARANTIE Les produits TIMBERWOLF sont fabriqu s conform ment aux normes strictes du Certificat d Assurance de Qualit ISO 9001 2000 mondialement reconnu Les produits TIMBERWOLF sont con us avec des composants et des mat riaux de qualit sup rieure assembl s par des artisans qualifi s qui sont fiers de leur travail Une fois assembl chaque appareil est soigneusement inspect par un technicien qualifi avant d tre emball pour garantir que vous le client recevez le produit de qualit dont vous vous attendez de TIMBERWOLF GARANTIE LIMIT E DES APPAREILS AU BOIS TIMBERWOLF Les mat riaux suivants et la fabrication de votre nouvel appareil TIMBERWOLF sont garantis contre les d fauts tel que d fini dessous La
14. vous travaillez l aveuglette sans aucune id e r elle du fonctionnement de votre appareil Un thermom tre d appareil vous donne une r f rence quant la performance de votre appareil Vous n arrivez pas faire partir votre feu Utilisez un peu plus de bois d allumage et de papier Si la chemi n e et le tuyau d vacuation sont de grandeur appropri e et s il y a suffisamment d air comburant alors le pro bl me est caus par une quantit insuffisante de petits morceaux de bois d allumage sec Le bois d allumage devrait avoir un diam tre quivalent celui de votre pouce Votre appareil n met pas assez de chaleur Une ou deux causes sont possibles La porte de l appareil a t ferm e pr matur ment et l appareil n a pas atteint sa temp rature optimale Ouvrez la porte et ou le con tr le de combustion nouveau afin de repartir un feu vif Du bois mouill pourrait tre la deuxi me cause Un bois gr sillant d ou s chappe de l humidit est le sympt me typique 7 1 M THODE POUR ASSURER UNE COMBUSTION OPTIMALE Pour une performance et une efficacit optimales quant aux missions suivez les directives simples suivantes lors de l utilisation de votre appareil A Maintenez une couche de braises chaudes de 2 po 51 mm B Br lez seulement du bois sec avec moins de 2096 d humidit et veillez ce que la porte vitr e reste propre C Un thermom tre de po le a bois doit indiquer une temp rature moyenne de 35
15. BE DONE BY A QUALIFIED ELECTRICIAN AND SHALL BE IN COMPLIANCE WITH LOCAL CODES IN THE ABSENCE OF LOCAL CODES USE THE CURRENT CSA C22 1 CANADIAN ELECTRIC CODE IN CANADA OR THE ANSI NFPA 70 NATIONAL ELECTRIC CODE IN THE UNITED STATES BURNING YOUR APPLIANCE WITH THE ASH WELL OPEN OR THE ASH DOOR AJAR CREATES FIRE HAZARD AND MAY CAUSE INTERNAL DAMAGE TO THE APPLIANCE OR A HOUSE AND OR CHIMNEY FIRE DO NOT CONNECT THIS APPLIANCE TO A CHIMNEY FLUE SERVING ANOTHER APPLIANCE DO NOT CONNECT TO ANY AIR DISTRIBUTION DUCT OR SYSTEM PROVIDE ADEQUATE CLEARANCE FOR SERVICING AND OPERATING THE APPLIANCE PROVIDE ADEQUATE VENTILATION NEVER OBSTRUCT THE FRONT OPENING OF THE APPLIANCE OBJECTS PLACED IN FRONT OF THE APPLIANCE MUST BE KEPT A MINIMUM OF 48 1219 2mm FROM THE FRONT FACE OF THE APPLIANCE DO NOT INSTALL IN A MOBILE HOME e Before beginning your installation consult with your local building code agency or fire officials and insurance representative to ensure compliance e Non toxic smoke will be emitted during the paint curing process to help dissipate the smoke open a window near the appliance e Remove any dust or debris off the top of the appliance before firing the appliance as the paint will become soft as the appliance heats up and will harden as the appliance cures To cure the paint on your appliance burn your appliance moderately hot during the first few fires e To keep the gasket from sticking to the
16. For serious wood burners chimney cleaning must be done as needed to avoid chimney fires the venting systems for controlled combustion appliances may need cleaning as often as once a month These rates however depend on the burning habits of the individual operating the appliance For example it is possible to clog a solid fuel appliance chimney in a few days if slow smoldering fires are burned and the chimney is cold NOTE Appliances burned consistently without hot fires may result in significant creosote accumulations in the chimney Certain items and considerations are important in chimney cleaning e Proper tools should be used including a brush specifically designed for cleaning e The chimney connector and dampers as well as the chimney should be cleaned e 5 firebox and baffle system should be cleaned needed e chimney should be inspected repairs made if needed preferably by qualified chimney sweep or mason 86 1 W415 1464 04 21 15 8 5 8 6 33 GLASS REPLACEMENT DO NOT USE SUBSTITUTE MATERIALS GLASS MAY BE HOT DO NOT TOUCH GLASS UNTIL COOLED CARE MUST BE TAKEN WHEN REMOVING AND DISPOSING OF ANY BROKEN DOOR GLASS OR DAMAGED COMPONENTS BE SURE TO VACUUM UP ANY BROKEN GLASS FROM INSIDE THE APPLIANCE BEFORE OPERATION DO NOT STRIKE SLAM OR SCRATCH GLASS DO NOT OPERATE APPLIANCE WITH GLASS REMOVED CRACKED BROKEN OR SCRATCHED A When the appli
17. N INSTALLEZ PAS D ENSEMBLE DE BUCHES GAZ NON VENTILEES DANS CET APPAREIL VOUS OBTENEZ UNE MEILLEURE EFFICACITE ET DES EMISSIONS PLUS FAIBLES AVEC DU BOIS DUR SECHE A L AIR QU AVEC DU BOIS RESINEUX OU VERT OU DES BOIS DURS FRAICHEMENT COUPES BRULER DU BOIS VERT OU HUMIDE PEUT CAUSER DES ACCUMULATIONS EXCESSIVES DE CREOSOTE LORSQU ALLUM E ELLE PEUT CAUSER UN FEU DE CHEMIN E ET UN INCENDIE GRAVE POURRAIT S ENSUIVRE N ENTREPOSEZ PAS LE BOIS L INT RIEUR DES D GAGEMENTS DE L APPAREIL OU DANS L ESPACE REQUIS POUR LE RAVITAILLEMENT OU L ENLEVEMENT DES CENDRES Lorsque vous chargez l appareil assurez vous que les d flecteurs en fibre dans le haut de l appareil ne se d placent pas Pour assurer une efficacit maximale lorsque l appareil est r chauff remplissez le avec du bois jusqu au haut de la porte de chargement et br lez en r glant feu moyen bas Des briques presque enti rement blanches et une vitre presque enti rement propre sont de bons indicateurs que votre appareil fonctionne efficacement Lorsque vous ne br lez que quelques b ches l appareil ne produira pas assez de chaleur ou le bois ne br lera pas compl tement Le combustible pour l appareil ne doit pas tre entrepos l int rieur des d gagements minimaux aux mat riaux combustibles mat riau sensible la chaleur N ENTREPOSEZ JAMAIS DE BOIS DANS LE COMPARTIMENT DU TIROIR CENDRES s il y a lieu NOTE Lorsque vous chargez l appareil assu
18. SUR LES COTES CHIMNEY CONNECTOR 6 152mm DIAMETER MINIMUM 24 GAUGE TYPE DE CHIMNEE CHEMIN E R SIDENTIELLE DE 6 DE DIAM TRE 152 mm la plaq ue d ho molog ation pour STEEL MINIMUM CLEARANCE FROM HORIZONTAL CONNECTOR AND HOMOLOGU E UL 103HT CEILING 18 455 RACCORD DE CHEMIN E DIAMETRE DE 6 152mm D ACIER DE CALIBRE 24 MINIMUM bte nir nfo rm ati on recise DO NOT OBSTRUCT SPACE UNDER HEATER 18 455mm DE DEGAGEMENT MINIMAL ENTRE LE RACCORD HORIZONTAL ET LB SPECIAL METHODS ARE REQUIRED WHEN PASSING A CHIMNEY PLAFOND THROUGH A WALL OR CEILING SEE INSTRUCTIONS AND BUILDING NE RIEN ENTREPOSER SOUS L APPAREIL N OT E L CODES DES M THODES SP CIALES SONT REQUISES LORSQUE UNE CHEMIN E TRAVE DO CONNECT THIS UNIT TO CHIMNEY FLUE SERVING UN MUR OU UN PLAFOND VOIR LES INSTRUCTIONS ET LES CODES BB TIMENT NOIE La plaque de Classe ANOTHER APPLIANCE NE PAS RACCORDER LA CHEMIN E D UN AUTRE APPAREIL FUEL FOR USE WITH SOLID WOOD FUEL ONLY DO NOT USE GRATE COMBUSTIBLE POUR USAGE AVEC LE BOIS SEULEMENT NUTILISE ment doit rester avec apparel OR ELEVATE FIRE BUILD WOOD FIRE DIRECTLY ON OU NE SURELEVEZ PAS LE BOIS PR PAREZ LE FEU DIRECTEMENT SU WARNING RISK OF SMOKE SPILLAGE OPERATE ONLY WITH DOOR AVERTISSEMENT RISQUE D CHAPPEMENT DE FUM E a tout le tem ps doit pas FULLY CLOSED LORSQUE LE POELE FONCTIONNE REMPLACEZ LA V REPLACE
19. according to manufacturers instructions Can t get the fire going Use more kindling and paper Assuming the chimney and vent are sized correctly and there is sufficient combustion air the lack of sufficiently dry quantities of small kindling is the problem Thumb size is a good gauge for small kindling diameter Can t get heat out of the appliance One of two things may have happened The appliance door may have been closed prematurely and the appliance itself has not reached optimum temperature Re open the door and or draft control to re establish a brisk fire The other problem may have been wet wood The typical symptom is sizzling wood and moisture being driven from the wood OPTIMUM BURN METHOD For optimal emissions performance and efficiency follow these simple guidelines when using your appliance A Maintain a 2 51mm deep hot glowing red coal bed B Burn dry seasoned wood with less than 20 moisture content and burn so that the glass door remains clean C A stove thermometer should indicate 350 F 176 C as an average temperature D Maintain a minimal trace of smoke coming from the chimney when the appliance is burning as intended E Inspect and replace all necessary components such as gaskets manifolds glass and other components which may affect the overall appliance performance Ensure adequate draft to control burn rate and temperature Refer to OPERATION and MAINTENANCE sections for det
20. appliance as the paint is curing periodically open the door every 5 10 minutes e For the first two weeks use generous amounts of fuel and burn the appliance with the damper wide open for an hour as the appliance goes through a process of eliminating moisture in the steel and firebricks The initial heat output will be reduced while the moisture is being drawn from the appliance and it will be necessary to build several hot fires to remove this moisture DURING THIS PROCESS DO NOT OVERFIRE THE APPLIANCE REDUCE THE AMOUNT OF AIR COMING INTO THE APPLIANCE IF THE APPLIANCE OR CHIMNEY BECOMES RED 415 1464 04 21 15 2 4 2 5 GENERAL INFORMATION DO NOT OPERATE THIS APPLIANCE WITHOUT THE LEGS PEDESTAL INSTALLED Both models EP21LA S and EP22PA S are similar in design and use the AIR INLET PATH same burning principles gt EXHAUST PATH They were specifically designed over many months of research to meet the 1990 U S A EPA particulate emission standards and have been extensively tested in Canadian and American laboratories This system is the most efficient simple and trouble free we know and works as follows a a 72 42 74 FLE ZE TZ Secondary air from the rear hole travels up the back in the secondary air housing to the manifold located at the top and shoots
21. chambre de combustion est garantie contre les d fauts pour une p riode de 25 ans Les tuyaux d air secondaire sont garantis contre les d fauts pour une p riode de cinq ans Toutes les autres pi ces soumises l usure et les composants lectriques tels que les ventilateurs les interrupteurs thermiques les interrupteurs l installation lectrique les rh ostats la brique r fractaire la vitre en c ramique cassure thermique seulement les d flecteurs en fibre et les joints d tanch it sont couverts Wolf Steel fournira gratuitement les pi ces de rechange durant la premi re ann e de la garantie limit e Les co ts de main d oeuvre relatifs aux r parations garanties ne sont pas couverts La fabrication de chaque mod le varie La garantie s applique uniquement aux composants disponibles avec votre appareil CONDITIONS ET LIMITATIONS Wolf Steel garantit ses produits TIMBERWOLF contre les d fauts de fabrication l acheteur d origine seulement L enregistrement de la garantie n est pas n cessaire Fournissez simplement une preuve d achat ainsi que le mod le et le num ro de s rie afin d effectuer une r clamation de garantie L achat doit avoir t fait par l entremise d un d taillant TIMBERWOLF autoris et sous r serve des conditions et limitations suivantes La couverture de la garantie d bute partir de la date d installation originale Cette garantie du fabricant n est pas transf rable et ne peut tre pro
22. extr mit gaufr e dans la buse de l appareil Ceci permettra la condensation qui se forme dans le conduit de raccordement de l appareil de s couler dans la chambre de combustion Chaque joint du conduit de raccordement doit tre x l aide d au moins trois vis autoperceuses Les recommandations suivantes pourraient tre utiles pour l installation du conduit de raccordement Le tuyau doit tre court et droit Pour une performance optimale toutes les courses horizontales devraient avoir une l vation minimale de 1 4 6 35 par pied et l extr mit sup rieure de la section devrait tre dirig e vers la chemin e Afin d assurer un fonctionnement s curitaire et ad quat de l appareil voir la section VACUATION Pour assurez un tirage ad quat la longueur horizontale du conduit ne doit jamais d passer 8 2 4 m 10 3 1 m Dans le cas d une installation verticale la longueur totale du conduit peut tre plus longue et le raccordement la chemin e peut tre fait sans probl me au niveau du plafond Un syst me de conduit ne devrait jamais avoir plus que deux coudes de 90 et ne devrait jamais commencer avec un coude de 90 Avant d utiliser un coude de 90 installez une section verticale d au moins 2 0 6 m partir de la buse Le conduit ne doit pas passer dans un mat riel combustible ou un espace ferm tels un grenier un entretoit ou un placard S il passe travers un mur un plafond ou dans
23. illustrated 9 0000000000000000000 00 0 co 0 0 0000000000000000040000 EP21LA S ILLUSTRATED 0 Le o Cg MM EP22PA S ILLUSTRATED W415 1464 04 21 15 5 6 BRICK AND BAFFLE INSTALLATION OPERATION OF THE APPLIANCE WITHOUT THE BAFFLES CAN RESULT IN EXCESSIVE TEMPERATURES THAT COULD DAMAGE THE APPLIANCE CHIMNEY AND THE SURROUNDING ENCLOSURE With the appliance and chimney installation completed move the bricks into place as illustrated below EP21LA S A Install the four A bricks two B bricks and two C bricks working from the back of the appliance forward as illustrated NOTE Left and right rear bricks have been cut model EP21LA S only B Install two A bricks along both sides of the appliance Install the four A brick
24. much condensation on the windows e Opening a window seems to alleviate the above symptoms e A ventilation system is installed in the house e Other devices are present that exhaust house air e The house has tight fitting windows and or is equipped with a well sealed vapour barrier Systems such as HRV s are designed to bring fresh air into your home and will resolve these related performance issues with your appliance W415 1464 04 21 15 11 4 0 INSTALLATION WEAR GLOVES AND SAFETY GLASSES FOR PROTECTION CAREFULLY FOLLOW THE INSTRUCTIONS FOR ASSEMBLY OF THE PIPE AND OTHER PARTS NEEDED TO INSTALL THE APPLIANCE FAILURE TO DO SO MAY RESULT IN A FIRE ESPECIALLY IF COMBUSTIBLES ARE TOO CLOSE TO THE APPLIANCE OR CHIMNEY AND AIR SPACES ARE BLOCKED PREVENTING THE FREE MOVEMENT OF COOLING AIR DO NOT DRAW OUTSIDE AIR FROM GARAGE SPACES EXHAUST PRODUCTS OF GASOLINE ENGINES ARE HAZARDOUS DO NOT INSTALL OUTSIDE AIR DUCTS SUCH THAT THE AIR MAY BE DRAWN FROM ATTIC SPACES BASEMENTS OR ABOVE THE ROOFING WHERE OTHER HEATING APPLIANCES OR FANS AND CHIMNEYS EXHAUST OR UTILIZE AIR THESE PRECAUTIONS WILL REDUCE THE POSSIBILITY OF APPLIANCE SMOKING OR AIR FLOW REVERSAL THE OUTSIDE AIR INLET MUST REMAIN CLEAR OF LEAVES DEBRIS ICE AND OR SNOW IT MUST BE UNRESTRICTED WHILE APPLIANCE IS IN USE TO PREVENT ROOM AIR STARVATION WHICH CAN CAUSE SMOKE SPILLAGE AND AN INABILITY TO MAINTAIN A FIRE SMOKE SPILLAGE CAN ALSO SET OFF SMOKE ALARMS NEGATIV
25. out laterally to oxidize the gases below the smoke exit 222222224 ee The lower combustion chamber is lined with high temperature firebricks on 2 sides the back and across the bottom with a layer of fibre baffles at the top to Al maintain high temperature in the combustion chamber so that gases mixing with the preheated air from the secondary air manifold tube are easily ignited and burned The appliance sides and back are shielded to direct the heat upwards and forwards into the room SSL Be sure to provide sufficient combustion air There are many other appliances in your home competing for air such as a kitchen range hood forced air heating devices clothes dryer or a bathroom exhaust fan After extended periods of non operation such as following a vacation or a warm weather season the appliance may emit a slight odour for a few hours This is caused by dust particles on the firebox burning off Open a window to sufficiently ventilate the room NATIONAL We suggest that our pellet hearth FIREPLACE products be installed and serviced by If outside air is utilized you should never experience a shortage of combustion air If professionals who are certified in the U S by the National Fireplace Institute NFI you choose not to utilize outside air and experien
26. que le volume d oxyg ne qui entre dans la chambre de combustion est moindre Cependant les flammes sont plus efficaces Elles continueront d tre paresseuses mais redeviendront plus grandes d s que les briques r fractaires auront t compl tement r chauff es et que la chemin e deviendra plus chaude produisant ainsi un meilleur tirage ce stade les grandes flammes que vous observez lorsque la porte est ouverte tirent inutilement l air r chauff de la piece dans la chemin e une situation qui est certes ind sirable C est pourquoi il faut toujours faire fonctionner l appareil avec la porte com pl tement ferm e lorsque les morceaux de bois de dimensions moyennes sont enflamm s Vous pouvez maintenant ajouter de plus gros morceaux de bois et faire fonctionner l appareil normalement Une fois que l appareil est compl tement r chauff il br lera tr s efficacement en laissant chapper que tr s peu de fum e par la chemin e Il y aura un lit de braises orang es dans la chambre de combustion et les flammes secondaires sautilleront juste au dessous des d flecteurs sup rieurs Vous pouvez sans crainte remplir la chambre de combustion avec du bois jusqu au sommet de la porte de chargement et vous obtien drez de meilleures flamb es si vous maintenez la temp rature du tuyau de l appareil entre 250 F 120 C et 450 F 270 Un thermom tre de surface vous aidera mieux contr ler la temp rature Sans thermom tre
27. taillant autoris POUR UN REMPLACEMENT DE PIECE SOUS GARANTIE UNE DE LA FACTURE ORIGI NALE SERA REQUISE AFIN DE POUVOIR HONORER LA DEMANDE Lorsque vous commandez des pi ces donnez toujours l information suivante e Mod le et num ro de s rie de l appareil e Date d installation de l appareil OMETTRE DE POSITIONNER LES PIECES e Num ro de la CONFORMEMENT AU MANUEL OU D UTILISER e Description de la pi ce UNIQUEMENT DES 5 SP CIFIQUEMENT e Fini APPROUVEES POUR CET APPAREIL PEUT IDENTIFIE LES ARTICLES QUI NE SONT PAS CAUSER DES DOMMAGES MAT RIELS ILLUSTR S POUR PLUS D INFORMATION CONTACTEZ VOTRE D TAILLANT AUTORIS OU DES BLESSURES CORPORELLES 41 1 COMPOSANTS woos smawagks BRIQUE 4 5 X 7 625 X 1 250 BRIQUE 2 X 9 X 1 250 BRIQUE 2 250 X 9 X 1 250 7 BRIQUE 2 750 X 9 X 1 250 N A ENSEMBLE COMPLET DE BRIQUES ENSEMBLE COMPLET DE BRIQUES D FLECTEUR EN FIBRE W018 0018 D FLECTEUR EN FIBRE 7 12 PARE CENDRES 13 VITRE JOINT D TANCH IT RECHANGE 14 VITRE AVEC JOINT D TANCH IT VITRE EN C RAMIQUE 5 MM 15 VITRE ET JOINT D TANCH IT DE RECHANGE 16 JOINT D TANCH IT DE VITRE 17 CHUTE CENDRES 18 TUYAU D AIR SECONDAIRE ARRI RE 19 TUYAU D AIR SECONDAIRE AVANT 20 TUYAU D AIR SECONDAIRE 1 BRIQUE4S x 6250 BRIQUE 4 5 X 7622 X 1 250 BRIQUEZX
28. une chemin e de utilisez soit des composants de chemin e pour cet usage ou des moyens acceptables de l autorit comp tente locale Cet appareil doit tre raccord A Une chemin e qui se conforme aux exigences des chemin es pr fabriqu es de type HT r sidentiel ou Une chemin e en magonnerie avec chemisage int gral conforme aux codes et aux exigences Ventilez le po le dans une chemin e de magonnerie ou dans une chemin e isol e en acier inoxydable certifi e Le tuyau de raccordement de 6 152 4mm de diam tre doit tre aussi court et aussi droit que possible Le raccordement la chemin e de ma onnerie doit se faire l aide d un manchon m tallique ou de ma onnerie ciment en place EMBOUT M LE DU CONDUIT VERS LA DE RACCOR BUSE DE DEMENT L APPAREIL DIRECTION DES GAZ DE COMBUSTION o DIE W415 1464 04 22 15 54 4 1 2 AJOUT DE SECTIONS Ajoutez des sections de chemin e selon les instructions d installation des manufacturiers La chemin e doit d passer le toit d au moins 3 0 9m de son point de contact avec la toiture et 2 0 6m tout mur toit ou difice se trouvant l int rieur d une distance horizontale de 10 3 1m MOINS DE 10 PIED 3m Y FR 2 PI 0 6m MIN FATE wm 3 PI 3 PI 10 PI 3m DE T 1m LA LIGNE DE MIN TOIT LE PLU PRES Cu MOINS DE 10 PIED 10 PI 3m Ba
29. vacuation les fournaises les s che linge etc Tout dommage caus l appareil la chambre de combustion l changeur de chaleur ou autres composants par l eau les dommages caus s par les intemp ries de longues p riodes d humidit la condensation des produits chimiques ou produits d entretien nuisibles ne seront pas la responsabilit de Wolf Steel Le nettoyage r gulier de la fine cendre g n r e durant le fonctionnement de cet appareil est n cessaire au bon entretien de votre appareil Tout dommage aux composants qui est attribuable un manque d entretien ne sera pas couvert par cette garantie Wolf Steel se r serve le droit de demander son repr sentant d inspecter tout produit ou pi ce TIMBERWOLF avant d honorer toute r clamation Toutes les pi ces remplac es en vertu de la politique de Garantie limit e ne peuvent faire l objet que d une seule r clamation Durant les dix premi res ann es Wolf Steel remplacera ou r parera les pi ces d fectueuses qui sont couvertes par la garantie vie limit e sa discr tion gratuitement Apr s les dix premi res ann es Wolf Steel fournira les pi ces de rechange 50 du prix de d tail courant Toutes les pi ces remplac es au titre de la garantie seront couvertes pour une p riode de 90 jours partir de leur date d installation Le fabricant peut exiger que les pi ces d fectueuses ou les produits soient retourn s ou que des photos num riques soient fournies
30. 0 176 C D Lors d une combustion normale vous devez maintenir un niveau minimal d manations de fum e provenant de la chemin e Inspectez et remplacez tous les composants n cessaires tels que les joints les collecteurs la vitre et d autres composants qui peuvent affecter l efficacit globale de l appareil F Assurez un tirage ad quat pour contr ler la rapidit de combustion et la temp rature Reportez vous aux sections FONCTIONNEMENT et ENTRETIEN pour plus de d tails 7 2 CONTR LE D AIR CET APPAREIL AU BOIS POSSEDE UN TAUX MINIMAL DE COMBUSTION ETABLI PAR LE FABRICANT QUI NE DOIT PAS TRE MODIFI LES REGLEMENTS F D RAUX INTERDISENT EN TATS UNIS DE MODIFIER R GLAGE OU D UTILISER CET APPAREIL DE CHAUFFAGE D UNE ALLANT L ENCONTRE DES INSTRUCTIONS DE FONCTIONNEMENT CONTENUES DANS CE MANUEL 415 1464 04 22 15 7 3 7 4 69 Le tirage est la force qui d place l air de la chambre de combustion vers le haut dans la chemin e La force de tirage de votre chemin e d pend de sa hauteur et de son diam tre de la g ographie locale des obstructions avoisinantes et autres facteurs D placer le contr le d air compl tement gauche r duit la temp rature CONTR LE D AIR Le contr le d air peut tre r gl pour passer d une combustion lente une com bustion rapide en d placant la manette de la gauche vers la droite Un tirage inad quat peut causer des refoulemen
31. 1 4 1 2 ADDING SECTIONS Add chimney sections according to the manufacturers installation instructions The chimney must extend at least 3 feet 1m above its point of contact with the roof and at least 2 feet 0 6m higher than any wall roof building or obstacle within 10 feet 8m horizontally LESS THAN 10 FEET 3m 2 FT 0 6m 2 0 6 RIDGE wr 3 FT 1m MIN I 10 FT 3m NEAREST ROOFLIN C 1 LESS 10 10 FT 3m lt m gt OR MORE zz PH j 3 FT 1 A 2 FT 0 6m i p m MIN I MIN H LL L L A FLAT ROOF WALL 59 1B An insulated stainless steel chimney must be supported at the ceiling or roof and its installation must comply with its manufacturer s instructions 415 1464 04 21 15 4 1 3 TYPICAL THROUGH THE CEILING A Move the stove into position with the flue centered midpoint between two joists to prevent having to cut them Use a plumb bob to line up the center B Cut and frame an opening in the ceiling to provide a 2 50 8mm clearance between the outside of the chimney and any combustible material DO NOT FILL THIS SPACE WITH ANY TYPE OF MATERIAL Nail headers between the joist for extra support Firestop spacers must be placed on the bottom of each framed opening in any floor or ceiling that the chimney passes through If your chimney system is enclosed within 4 gt
32. 2 3 INFORMATION G N RALE CET APPAREIL DOIT TRE RACCORD LECTRIQUEMENT PAR UN LECTRICIEN QUALIFI CONFORM MENT AUX CODES LOCAUX EN L ABSENCE DE CODES LOCAUX UTILISEZ LA VERSION COURANTE DU CODE CANADIEN DE L ELECTRICITE CSA C22 1 AU CANADA OU LE NATIONAL ELECTRIC CODE ANSI NFPA 70 AUX TATS UNIS FAIRE VOTRE APPAREIL AVEC LA CHUTE CENDRES OU LA PORTE DU TIROIR A CENDRES OUVERTE OU ENTROUVERTE CONSTITUE UN RISQUE D INCENDIE QUI PEUT CAUSER DES DOMMAGES INTERNES L APPAREIL UN INCENDIE OU UN FEU DE CHEMINEE NE RACCORDEZ PAS CET APPAREIL AU CONDUIT D UNE CHEMIN E DESSERVANT UN AUTRE APPAREIL NE RACCORDEZ AUCUN AUTRE CONDUIT OU SYSTEME DE DISTRIBUTION D AIR PREVOYEZ UN ACCES SUFFISANT POUR ENTRETENIR ET OP RER L APPAREIL ASSUREZ VOUS D UNE QUANTIT SUFFISANTE D AIR N OBSTRUEZ JAMAIS L OUVERTURE SUR LE DEVANT DE L APPAREIL LES OBJETS PLAC S DEVANT L APPAREIL DOIVENT TRE GARD S UNE DISTANCE MINIMALE DE 48 DELA FACE AVANT DE L APPAREIL N INSTALLEZ PAS CET APPAREIL DANS UNE MAISON MOBILE e Avant d installer cet appareil contactez les autorit s locales en b timent ou le service des incendies et votre compagnie d assurance afin de vous conformer leurs directives e De la fum e non toxique manera de l appareil lors du processus de cuisson de la peinture Ouvrez une fen tre proximit de l appareil pour aider dissiper la fum e e Enlevez la poussi re ou les d
33. 8 1 1 DES CENDRES 71 8 2 FORMATION DE LA CR OSOTE 72 8 3 FEU DE CHEMIN E OU FEU HORS CONTR LE 72 8 4 NETTOYAGE LA CHEMIN E 12 8 5 REMPLACEMENT DE LA VITRE 73 8 6 REMPLACEMENT DES JOINTS D TANCH IT 73 8 7 SOINS DE LA VITRE 74 8 8 BOIS 75 9 0 RECHANGES 76 10 0 GUIDE DE DEPANNAGE 78 11 0 GARANTIE 79 NOTE Les modifications autres qu ditoriales sont indiqu es par une ligne verticale dans la marge 415 1464 04 22 15 43 1 0 VUE D ENSEMBLE DE L INSTALLATION Plaque d homologation voir la section INFORMATION SUR vacuation voir la section LA PLAQUE INSTALLATION CHEMIN E D HOMOLOGATION Voir la section TIRAGE Soufflerie voir la section INSTALLATION DE LA SOUFFLERIE OPTIONNELLE Poign e voir la section INSTALLATION DE LA POIGNEE DE PORTE Tiroir 8 cendres voir la section Ecran thermique ENSEMBLE TIROIR A CENDRES voir la section OPTIONNEL EP20LAD pour le INSTALLATION DES mod le sur pattes et la section PATTES ENSEMBLE TIROIR A CENDRES OPTIONNEL EP20PAD pour le mod le sur pi destal W415 1464 04 22 15 T 2 44 2 0 INTRODUCTION CET APPAREIL EST CHAUD LORSQU IL FONCTIONNE ET PEUT CAUSER DE GRAVES BR LURES EN CAS DE CONTACT TOUTE MODIFICATION APPORT E CET APPAREIL OU AUX CONTR LES PEUT TRE DANGEREUX ET EST INTERDIT Ne faites pas fonctionner l app
34. ACT PEUT CAUSER DES BRULURES AL A PEAU VOIR LA PLAQUE D HOMOLOGATION ET LES INSTRUCTIONS U S Environmental Protection Agency Certified to comply with July 1990 particulate emissions standards Certifi conforme la norme d manation NAC GUANGZHOU P R C particles de juillet 1990 EPA 2100 NO 69 HEFENG ROAD GUANGZHOU CHINA W385 0465 J 2100 SERIES RATING PLATE ILLUSTRATED WOLF STEEL LTD 24 NAPOLEON ROAD BARRIE L4M 008 CANADA MODEL MODELE 2100 U S ENVIRONMENTAL PROTECTION AGENCY Certified to comply with 2015 particulate emissions standards Not approved for sale after May 15 2020 Certifi conforme la norme d manation de particles de 2015 Non approuv pour la vente apr s le 15 mai 2020 40 CFR Part 60 Subpart AAA 3 9 Grams Per Hour 2015 Crib Wood 3 9 Grammes par heure Crib Wood 2015 This wood appliance needs periodic inspection and repair for proper operation Consult the owner s manual for further information it is against federal regulations to operate this wood appliance in a manner inconsistent with the operating instructions in the owner s manual Cet appareil au bois doit faire l objet d une inspection et d un entretien p riodiques pour un fonctionnement ad quat Consultez le manuel d instructions pour plus d information Les r glements f d raux interdisent d utiliser cet appareil de chauffage d une mani re allant l encontre des instructions de fonctionneme
35. E LA PI CE NE SOIT PAS PRIV E D AIR CE QUI PEUT CAUSER DES REFOULEMENTS DE FUMEE OU UNE INCAPACITE A MAINTENIR UN FEU LES REFOULEMENTS DE FUMEE PEUVENT AUSSI DECLENCHER LES DETECTEURS DE FUMEE UNE PRESSION N GATIVE DANS LA MAISON POURRAIT NUIRE AU RENDEMENT DE L APPAREIL _ AFIN D VITER TOUT CONTACT AVEC DE L ISOLANT QUI S AFFAISSE L APPAREIL NE DOIT PAS ETRE INSTALLE CONTRE UN COUPE VAPEUR OU DE L ISOLANT A DECOUVERT UNE SURCHAUFFE LOCALISEE PEUT SURVENIR ET UN INCENDIE POURRAIT S ENSUIVRE N UTILISEZ PAS DE COMPROMIS DE FORTUNE LORS DE L INSTALLATION N OBSTRUEZ PAS ENTIEREMENT NI PARTIELLEMENT LES OUVERTURES D AIR LES GRILLES OU LES PERSIENNES N AJOUTEZ PAS DE HOTTE GARDEZ VOS OUTILS MAIN EN BON TAT AFF TEZ LES TRANCHANTS ET ASSUREZ VOUS QUE LES MANCHES SONT SOLIDES EN TOUT TEMPS CONSERVEZ L ESPACE VIDE MINIMAL REQUIS L ENCEINTE AFIN DE PR VENIR LES INCENDIES 68 3 415 1464 04 22 15 52 4 11 NE JAMAIS INSTALLER UN CONDUIT DE RACCORDEMENT PAROI SIMPLE DANS UNE ENCEINTE LES TEMP RATURES PLUS LEV ES DE CE CONDUIT PEUVENT IRRADIER SUFFISAMMENT DE CHALEUR AUX MAT RIAUX COMBUSTIBLES POUR CAUSER UN INCENDIE NE RACCORDEZ PAS CET APPAREIL AU CONDUIT D UNE CHEMIN E DESSERVANT UN AUTRE APPAREIL POUR VITER LE RISQUE D INCENDIE VOUS DEVEZ SUIVRE TOUTES LES INSTRUCTIONS LA LETTRE INCLUANT LES D GAGEMENTS ENTRE LE SYST ME DE CO
36. E PRESSURE WITHIN YOUR HOME MAY INADVERTENTLY AFFECT YOUR APPLIANCE TO PREVENT CONTACT WITH SAGGING OR LOOSE INSULATION THE APPLIANCE MUST NOT BE INSTALLED AGAINST VAPOUR BARRIERS OR EXPOSED INSULATION LOCALIZED OVERHEATING COULD OCCUR AND A FIRE COULD RESULT DO NOT USE MAKESHIFT COMPROMISES DURING INSTALLATION DO NOT BLOCK OR RESTRICT AIR GRILLE OR LOUVRE OPENINGS DO NOT ADD A HOOD KEEP HAND TOOLS IN GOOD CONDITION SHARPEN CUTTING EDGES AND MAKE SURE TOOL HANDLES ARE SECURE ALWAYS MAINTAIN THE MINIMUM AIR SPACE REQUIRED TO THE ENCLOSURE TO PREVENT FIRES 68 3A W415 1464 04 21 15 12 4 1 CHIMNEY NEVER INSTALL A SINGLE WALL SLIP SECTION OR SMOKE PIPE IN A CHASE STRUCTURE THE HIGHER TEMPERATURE OF THIS SINGLE WALL PIPE MAY RADIATE SUFFICIENT HEAT TO COMBUSTIBLE CHASE MATERIALS TO CAUSE A FIRE DO NOT CONNECT THIS APPLIANCE TO A CHIMNEY SYSTEM SERVING ANOTHER APPLIANCE TO AVOID DANGER OF FIRE ALL INSTRUCTIONS MUST BE STRICTLY FOLLOWED INCLUDING THE PROVISION OF AIR SPACE CLEARANCE BETWEEN CHIMNEY SYSTEM AND ENCLOSURE TO PROTECT AGAINST THE EFFECTS OF CORROSION ON THOSE PARTS EXPOSED TO THE WEATHER WE RECOMMEND THAT THE CHASE TOP BE PAINTED WITH A RUST RESISTANT PAINT DO NOT FILL ANY FRAMED SPACE AROUND THE CHIMNEY WITH INSULATION OR ANY OTHER MATERIAL INSULATION PLACED IN THIS AREA COULD CAUSE ADJACENT COMBUSTIBLES TO OVERHEAT MAINTAIN A MINIMUM 2 50 8mm AIR CLEARANCE TO ALL PARTS OF THE CHIMNEY SY
37. EAVE CHILDREN UNATTENDED WHEN THERE IS A FIRE BURNING IN THE APPLIANCE NEVER USE GASOLINE GASOLINE TYPE LANTERN FUEL KEROSENE CHARCOAL LIGHTER FLUID OR SIMILAR LIQUIDS TO START OR FRESHEN UP A FIRE IN THIS APPLIANCE KEEP ALL SUCH LIQUIDS WELL AWAY FROM THE APPLIANCE WHILE IT IS IN USE OBJECTS PLACED IN FRONT OF THE APPLIANCE SHOULD BE KEPT A MINIMUM OF 48 FROM THE FRONT FACE ANY MODIFICATION OF THE APPLIANCE THAT HAS NOT BEEN APPROVED IN WRITING BY THE TESTING AUTHORITY IS CONSIDERED BREACHING CSA 8365 CANADA AND ANSI NFPA 211 USA OPEN AIR CONTROL AND DAMPER WHEN FITTED BEFORE OPENING FIRING DOOR HOT WHILE IN OPERATION KEEP CHILDREN CLOTHING AND FURNITURE AWAY CONTACT MAY CAUSE SKIN BURNS WEAR GLOVES TO OPERATE YOUR APPLIANCE BURNING YOUR APPLIANCE WITH THE DOORS OPEN OR AJAR CREATES A FIRE HAZARD THAT MAY RESULT IN A HOUSE AND OR CHIMNEY FIRE THIS WOOD APPLIANCE HAS A MANUFACTURER SET MINIMUM LOW BURN RATE THAT MUST NOT BE ALTERED IT IS AGAINST FEDERAL REGULATIONS IN THE UNITED STATES TO ALTER THIS SETTING OR OTHERWISE OPERATE THIS WOOD APPLIANCE IN A MANNER INCONSISTENT WITH OPERATING INSTRUCTIONS IN THIS MANUAL Your Timberwolf EPA listed product is a Hi tech appliance designed with the most advanced technology The appliance is extremely airtight The first fire s in your appliance will be difficult to get going and keep going with little amount of heat being generated This is a result of the moistur
38. ED HARDWOODS AS COMPARED TO SOFTWOODS OR TOO GREEN OR FRESHLY CUT HARDWOODS BURNING WET UNSEASONED WOOD CAN CAUSE EXCESSIVE CREOSOTE ACCUMULATION WHEN IGNITED IT CAN CAUSE A CHIMNEY FIRE THAT MAY RESULT IN A SERIOUS HOUSE FIRE DO NOT STORE FUEL WITHIN THE CLEARANCE TO COMBUSTIBLES OR IN THE SPACE REQUIRED FOR RE FUELING AND ASH REMOVAL When loading the appliance ensure that the upper fibre baffles are not forced out of position For maximum efficiency when the appliance is thoroughly hot load it fully to the top of the door opening and burn at a medium low setting The whiteness of the bricks and the cleanliness of the glass are good indicators of your operating efficiency Not enough heat is produced when only a few pieces of wood are burned or the wood may not burn completely Fuel for the appliance must not be stored closer than the required clearances to combustibles heat sensitive material NEVER STORE WOOD IN THE ASH PAN COMPARTMENT if applicable NOTE When loading the appliance ensure to keep fuel back from the glass If coals are to accumulate on the front lip there is a chance they will fall out when the door is opened Burn only dry clean unpainted wood that has been seasoned It produces more AIR FLOW heat and less soot or creosote Freshly cut wood contains about 5096 moisture ml while after proper seasoning only about 20 of the 9 water remains As wood is burned this water boils off consuming energy tha
39. ED SOLID FUEL BURNING SPACE HEATER Pour l emplacement de la GH enn POELE COMBUSTIBLE SOLIDE HOMOLOGUE plaque d homologation voir la c _ tele UL1482 ULC S627 CSA B366 2 DEC 92 H CMI Tesi 1 section VUE D ENSEMBLE REPORT NO NUM RO DE RAPPORT 415 S 02 2 MODEL MODELE 2100 INSTALLAND USE ONLY INACCORDANCE WITH WOLF STEEL LTD S POUR INSTALLATION ET UTILISATION CONFORM MENT AUX INSTRUCTIONS DE DE L INSTALLATION a INSTRUCTIONS CONTACT LOCAL BUILDING OR FIRE OFFICIALS ABOUT WOLF STEEL LT E RENSEIGNEZ VOUS AUPR S DES AUTORIT S LOCALES DU RESTRICTIONS AND INSTALLATION INSPECTION IN YOUR AREA B TIMENT OU DU MINIMUM CEILING HEIGHT 7FT 2 13m SERVICE DES INCENDIES AU SUJET DES RESTRICTIONS ET DES INSPECTIONS HEARTH EXTENSION COMBUSTIBLE FLOOR PROTECTION IF D INSTALLATION DANS VOTRE R GION N 1 INSTALLED ON A COMBUSTIBLE FLOOR UNIT MUST BE PLACED ON A HAUTEUR DE PLAFOND MINIMAL 7 2 13mm Cette illustration est a titre de NON COMBUSTIBLE FLOOR PROTECTOR EXTENDING 18 455mm PROLONGEMENT D ATRE PROTECTION DU PLANCHER COMBUSTIBLE SI INSTALL NAM FRONT AND 8 205mm TO THE SIDES AND BACK SUR UN PLANCHER COMBUSTIBLE L APPAREIL DOIT TRE PLAC SUR UNE r f rence seulement Consultez CHIMNEY TYPE MINIMUM 6 152mm DIAMETER LISTED UL 108HT PLAQUE PROTECTRICE INCOMBUSTIBLE S TENDANT SUR 18 455mm L AVANT RESIDENTIAL CHIMNEY ET 8 205mm L ARRI RE ET
40. EILING WALL SPACER FOR OUTSIDE WALL CHIMNEY CONNECTOR FLOOR COMBUSTIBLE PROTECTOR WALL 415 1464 04 21 15 1 4 1 5 TYPICAL EXISTING MASONRY You can also install your appliance using your existing masonry chimney To do so follow the guidelines below Use a factory built thimble or construct your own brick thimble If you are ri using masonry it is important that it S RE T be built in compliance with the specifications EDRN of the Building Code in your region It must di d normally be lined with fire bricks metal BER ae EAVE or clay tiles sealed together with fire cement CLEARANCE WITH FIRESTOP gt lt Round flues are the most efficient The maximum flue size is 8 203 2mm x 8 __ 203 2mm square or 6 152 4mm round CEILING JOIST For greater diameters it is necessary to install a 6 stainless steel liner Be CLEARANCE COMBUSTIBLE WALL l m ut CONNECTOR 1 1 FLOOR PROTECTOR 111111111111 1111 62 1 W415 1464 04 21 15 18 5 0 FINISHING 5 1 LEG INSTALLATION KNOCKOUT NOT TO BE REMOVED EXCEPT WHEN INSTALLING THE OPTIONAL ASH DRAWER KIT To avoid being damaged during shipping the appliance has been bolted to the pallet and must be unbolted before the appliance can be installed NOTE If installing the optional ash drawer see OPTIONAL AS
41. ER LES CENDRES ASSUREZ VOUS QUE CES DERNI RES SOIENT ENTI REMENT REFROIDIES L UTILISATION D UN ASPIRATEUR POUR NETTOYER LES CENDRES CHAUDES POURRAIT OCCASIONNER UN INCENDIE DANS L ASPIRATEUR NE FAITES JAMAIS FONCTIONNER VOTRE APPAREIL SI L OUVERTURE DE LA CHUTE CENDRES N EST PAS TANCHE SI LE JOINT ENTRE L OUVERTURE LE COUVERCLE ET LA PORTE DE LA CHUTE A CENDRE N EST PAS TANCHE CELA ENTRA NERA UNE SURCHAUFFE POUVANT ENDOMMAGER L APPAREIL Laissez les cendres s accumuler sur une paisseur de deux ou trois pouces sur le plancher de la chambre de combustion elles ont tendance se consumer Une fois que le feu s est teint et que les cendres se sont refroidies enlevez toutes les cendres exc dentaires mais laissez une paisseur d un pouce 25 4 mm sur le plancher de la chambre de combustion pour aider conserver un lit de braises chaudes LIMINATION DES CENDRES Les cendres doivent tre plac es dans un contenant m tallique avec un cou vercle herm tique Le contenant ferm doit tre plac sur une surface incombustible une distance loign e de tout mat riau combustible jusqu ce que vous les jetiez Si les cendres sont enterr es ou dispers es loca lement elles devraient demeurer dans le contenant m tallique jusqu ce qu elles aient compl tement refroidi 8 1 1 ENLEVEMENT DES CENDRES e Pour enlever les cendres nettoyez la r gion autour du couvercle de la chute cendres Retirez ensuite l
42. EU DE CHEMINEE ET UN INCENDIE GRAVE POURRAIT S ENSUIVRE Lorsque vous chargez l appareil assurez vous que les deux d flecteurs en fibre du haut de l appareil n ont pas t soulev s et d plac s de leur rebord Pour assurer une efficacit maximale lorsque l appareil est r chauff remplissez le avec du bois jusqu au sommet de la porte de chargement et br lez en r glant feu moyen bas On obtient une chaleur maximale pour un minimum de combustible efficacit maximale quand le haut de l appareil sous la grille ornementale atteint des temp ratures entre 500 F 260 C et 600 F 315 C Les briques seront presque enti rement blanches et la vitre presque enti rement propre Ceci est un bon indicateur que votre appareil fonctionne efficacement Lorsque vous ne br lez qu une ou deux b ches l appareil ne produira pas assez de chaleur ou le bois ne br lera pas compl tement faut au moins 3 b ches pour arriver avoir un lit de braises qui nourrira le feu NOTE Lorsque vous chargez l appareil assurez vous de garder le combustible loign de la vitre Si des braises s accumulent sur le rebord avant elles pourraient tomber hors de l appareil quand vous ouvrez la porte Des b ches plac es de fa on l che br leront plus rapidement que celles plac es serr es les unes contre les autres Le bois br le de facon cyclique au lieu de fournir une chaleur constante est donc pr f rable de planifier ces cycles en fonction
43. FORMATION G N RALE 46 2 5 AVERTISSEMENT PROPOSITION 65 DE LA CALIFORNIE 47 2 4 INSTRUCTIONS G N RALES 47 2 6 INFORMATION SUR LA PLAQUE D HOMOLOGATION 48 3 1 INSTALLATION DE L APPAREIL 49 3 2 D GAGEMENTS AUX MAT RIAUX COMBUSTIBLES 49 3 3 INSTALLATION DANS UNE ALC VE 49 3 0 PLANIFICATION DE L INSTALLATION 49 3 5 AIR EXT RIEUR 50 3 4 PROTECTION DU PLANCHER 50 4 0 INSTALLATION 51 4 1 CHEMIN E 52 4 1 1 INSTALLATION DE LA CHEMIN E 53 41 2 AJOUT DE SECTIONS 54 41 3 TYPIQUE TRAVERS LE PLAFOND 55 4 1 4 INSTALLATION TYPIQUE TRAVERS UN MUR 56 4 1 5 INSTALLATION TYPIQUE DANS UNE CHEMIN E MA ONNERIE EXISTANTE 57 5 0 FINISHING 58 5 1 INSTALLATION DES PATTES 58 5 2 INSTALLATION DU PI DESTAL 59 5 3 ENL VEMENT DE LA PORTE 59 5 4 INSTALLATION DE LA POIGN E DE PORTE 60 5 5 TUYAUX D AIR SECONDAIRE 61 5 6 INSTALLATION DES BRIQUES ET DES D FLECTEURS EN FIBRE 62 5 7 INSTALLATION DU PARE CENDRES 63 6 0 INSTALLATION OPTIONNELLE 64 6 1 INSTALLATION DE LA SOUFFLERIE 64 6 2 ENSEMBLE TIROIR CENDRES EP20LAD 65 6 3 ENSEMBLE TIROIR CENDRES EP20PAD 66 7 0 FONCTIONNEMENT 67 7 1 M THODE POUR ASSURER UNE COMBUSTION OPTIMALE 68 7 2 CONTR LE D AIR 68 7 3 EXTINCTEURS D TECTEURS DE FUM E MONOXYDE DE CARBONE 69 7 4 COMBUSTIBLE 69 7 5 ALLUMER UN FEU 70 7 5 1 FEU CLAIR 70 7 5 2 FEU CONTINU 70 7 6 PROBL MES DE FUM E 70 8 0 ENTRETIEN 71 8 1 ENL VEMENT DES CENDRES AVEC TIROIR CENDRES 71
44. GLASS ONLY WITH GLASS C RAMIQUE SEULEMENT t re en lev DO NOT OVERFIRE IF HEATER OR CHIMNEY CONNECTORS GLOW SURCHAUFFEZ PAS L APPAREIL SI L APPAREI YOU ARE OVERFIRING INSPECT AND CLEAN CHIMNEY FREQUENTLY L APPAREIL SURCHAUFEE INSPECTEZ NETT UNDER CERTAIN CONDITIONS OF USE CREOSOTE BUILD UP MAY OCCUR DANS CERTAINES CONDITIONS DES DEPOTS DE RAPIDLY RAPIDEMENT OPTIONAL LEGS IF BE INSTALLED WITH OPTIONAL LEGS LEGS PATTES OPTIONNELLES SI LES PAITES OPTIONNEL MUST BE INSTALLED PRIOR TO OPERATION DOIVENT TRE INSTALL ES AVANMIDE FAIRE FONCTIONNERIBAPPAREIL OPTIONAL BLOWER KIT EP 65 115V 60HZ 0 82AMP ROUTE CORD SOUFFLERIE OPTIONNELLE 60HZ 0 82A TENEZ LE CORDON LECTRIQUE AWAY FROM UNIT LOIN DE L APPAREIL DANGER RISK OF ELECTRICAL SHOCK DISCONNECT POWER DANGER RISQUE DE SECOUSSE D EZ AVANT DE PROC DER BEFORE SERVICING UNIT L ENTRETIEN PARALLEL PARALL LE CORNER COIN 9 FLOOR PROTECTION PROTECTION BACK WALL BACK WALL DE PLANCHER 2 a lt o PARALLEL amp CORNER L CONNECTOR DOUBLE WALL CONNECTOR PARALLELE amp COIN ORDEMENT TUYAU DE RACCORDEMENT PAROI SIMPLE PAROI DOUBLE SIDEWALL A ON 19 BACKWALL B b N 17 1 2 12 1 2 CORNER C gt 7 ALCOVE un 1 h o w 00047 ad Ww iw wz dth 64 Minimum depth 32 FLOOR PROTECTION PROTECTION DE PLANCHER SIDES C T S
45. H BACK ARRI RE MANUFACTURE DATE DATE DE FABRICATION B 2012 H 2013 2014 JAN JANV APR AVR Wu OCT OCT B vaya AUG AOUT Nov Nov l MAR MARS JUN JUIN SEP SEPT DEC DEC C A U T HOT WHILE OPERATION DO NOT TOUCH KEEP CHILDREN JEANS 1 N CLOTHING AND FURNITURE AWAY CONTACT MAY CAUSE SKIN BURNS SEE NAMEPLATE AND INSTRUCTIONS ATTE NT QUAND L APPAREIL FONCTIONNE LA SURFACE DEVIENT CHAUDE NE PAS TOUCHER TENIR LES ENFANTS LES V TEMENTS ET LES MEUBLES L ECAR LE CONTACT PEUT CAUSER DES BR LURES AL A PEAU VOIR LA PLAQUE D HOMOLOGATION ET LES INSTRUCTIONS WOLF STEEL LTD U S Environmental Protection Agency Certified to comply with July 1990 24 NAPOLEON ROAD BARRIE ON particulate emissions standards Certifi conforme la norme d manation de LAM 0G8 CANADA particles de juillet 1990 NAC GUANGZHOU PR C 88 40 CFR Part 60 Subpart AAA 2100 69 HEFENG ROAD GUANGZHOU CHINA W385 0465 PLAQUE D HOMOLOGATION DU POELE ILLUSTR E 2100 MODEL MOD LE 2100 U S ENVIRONMENTAL PROTECTION AGENCY Certified to comply with 2015 particulate emissions standards Not approved for sale after May 15 2020 Certifi conforme la norme d manation de particles de 2015 Non approuv pour la vente apr s le 15 mai 2020 40 CFR Part 60 Subpart AAA 3 9 Grams Per Hour 2015 Crib Wood 3 9 Grammes par he
46. H DRAWER KIT EP20LAD section prior heat shield and leg installation NOTE Legs may need to be adjusted in order to properly align with the heat shield holes A With the bolt through the legs feed the washer and lock washer onto the bolt Thread the nut a thread or two onto the bolt and slide the leg onto the slot on appliance as illustrated NOTE Bolts must be tight prior to heat shield installation B Slide the heat shield over the four bolts Finally secure the heat shield in place using the remaining nuts C Lift the appliance up and gently set down on all four legs Do not pivot appliance up on its legs as this could result in damage to the legs KNOCKOUT 5 SEE WARNING ABOVE For additional logo placement locations see OPTIONAL ASH DRAWER section LOGO PLACEMENT 415 1464 04 21 15 3 2 5 3 PEDESTAL INSTALLATION NOTE If an optional ash drawer kit is to be installed ensure open side of pedestal is at the front of the appliance If not opening should be at the back To avoid being damaged during shipping the appliance has been bolted to the pallet and must be unbolted before the appliance can be installed A Using the machine screws supplied secure the pedestal to the four brackets on the bottom of the firebox B Lift the appliance up and genily set down on
47. IGNNELLES SONT INSTALL ES ELLES DOIVENT ETRE INSTALLEES AVANT DE FAIREFONCTIONNER L APPAREIL SOUFELERIE OPTIONNELLE EP lt 115V 60HZ 0 82A TENEZ LE CORDON LECTRIQUE LOIN DE L APPAREIL DANGER RISQUE DE SECOUSSE LECTRIQUE D BRANCHEZ AVANT DE PROC DER PENTRETIEN S ALCOVE ALC VE v FLOOR PROTECTION PROTECTION BACK WALL 4 lt a PARALLEL amp CORNER PARALLELE amp COIN BACK WALL SIDE WALL SINGLE WALL CONNECTOR TUYAU DE RACCORDEMENT A PAROI SIMPLE DE PLANCHER DOUBLE WALL CONNECTOR TUYAU DE RACCORDEMENT A PAROI DOUBLE 17 1 2 12 1 2 CORNER C di O 11 ALCOVE ALC VE CEILING NOTE Minimum width 64 Minimum depth 32 FLOOR PROTECTION PROTECTION DE PLANCHER FRONT AVANT I SIDES COTES H CANADA 8 8 USA 19 8 J 8 MANUFACTURE DATE DATE DE FABRICATION gn 2015 2016 2017 B 2018 B J N JANV PR AVR W JUL JUILL B OCT OCT FEB FEVR MAYA AUG AOUT Nov Nov MAR MARS Bl JUN JUIN SEP SEPT B DEC DEC CA U T HOT WHILE OPERATION DO NOT TOUCH KEEP CHILDREN CLOTHING AND FURNITURE AWAY CONTACT MAY CAUSE d SKIN BURNS SEE NAMEPLATE AND INSTRUCTIONS O QUAND L APPAREIL FONCTIONNE LA SURFACE DEVIENT CHAUDE NE PAS TOUCHER TENIR LES ENFANTS LES VETEMENTS ET LES MEUBLES A L ECAR LE CONT
48. IL PROPRIETAIRE CONSERVEZ CE MANUEL POUR CONSULTATION ULTERIEURE NE LAISSEZ PAS LES ENFANTS OU AUTRES INDIVIDUS A RISQUE SEULS A PROXIMITE DE L APPAREIL INSTRUCTIONS D INSTALLATION ET TIMBERWOLF D OP RATION LE MOD LE EP21LA S amp EP22PA S RESPECTE L AGENCE DE PROTECTION DE L ENVIRONNEMENT AM RICAINE E P A 2015 ES LIMITES D MISSIONS DE BOIS DE VALEUR STANDARD POUR LES PO LES BOIS VENDUS APR S LE 15 MAI 2015 40 C F R SECTION 60 CES APPAREILS ONT T TEST S ET HOMOLOGU S PAR OMNI TESTING SERVICES SELON LES NORMES CSA B366 2 ULC S627 ET UL 1482 EP21LA S EP22PA S MODELES SUR PATTES ET MODELES SUR PIEDESTAL CONSIGNES DE SECURITE AVERTISSEMENT Si ces instructions ne sont pas suivies la lettre un incendie ou une explosion pourraient s ensuivre causant des dommages mat riels des blessures corporelles ou des pertes de vie Une installation non conforme des ajustements des alt rations un service ou un entretien inad quats peuvent causer des dommages mat riels des blessures corporelles et des pertes de vie Veuillez lire le manuel en entier avant d installer et d utiliser cet appareil Cet appareil n a pas t test avec un ensemble de b ches gaz non ventil es Afin n installez pas d ensemble de b ches gaz non ventil es dans cet appareil Cet appareil peut devenir tr s chaud lorsqu il fonctionne Les mat riaux combustibles tels que le bois de chauffage les v tements mo
49. INSTALLER LEAVE THIS MANUAL WITH THE APPLIANCE CONSUMER RETAIN THIS MANUAL FOR FUTURE REFERENCE NEVER LEAVE CHILDREN OR OTHER AT RISK INDIVIDUALS ALONE WITH THE APPLIANCE INSTALLATION AND TIMBERWOLF OPERATING INSTRUCTIONS o MODELS EP21LA S amp EP22PA S MEETS THE 2015 U S ENVIRONMENTAL PROTECTION AGENCY E P A CRIB WOOD EMISSION LIMITS FOR WOOD STOVES SOLD AFTER MAY 15 2015 40 C F R PART 60 THESE APPLIANCES HAVE BEEN TESTED AND LISTED BY OMNI TESTING SERVICES TO STANDARDS ULC 5627 00 UL 1482 1996 EP21LA S EP22PA S LEG MODELS amp PEDESTAL MODELS SAFETY INFORMATION If the information in these instructions is not followed exactly a fire or explosion may result causing property damage personal injury or death Improper installation adjustment alteration service or maintenance can cause injury or property damage bodily injury or even death Please read entire manual before you install and use your appliance This appliance can be very hot when burning Combustible materials such as firewood wet clothing etc placed too close can catch fire Children and pets must be kept from touching the appliance when it is hot The chimney must be sound and free of cracks Before installing this unit contact the local building or fire authority and follow their guidelines HOT GLASS WILL CAUSE Operate only w
50. IT MUST BE PLACED ONA NON COMBUSTIBLE FLOOR PROTECTOR EXTENDING 18 455mm IN FRONT AND 8 205mm TO THE SIDES AND BACK CHIMNEY TYPE MINIMUM 6 152mm DIAMETER LISTED UL 103HT RESIDENTIAL CHIMNEY CHIMNEY CONNECTOR 6 152mm DIAMETER MINIMUM 24 GAUGE STEEL MINIMUM CLEARANCE FROM HORIZONTAL CONNECTOR AND CEILING 18 455mm DO NOT OBSTRUCT SPACE UNDER HEATER SPECIAL METHODS ARE REQUIRED WHEN PASSING A CHIMNEY THROUGH A WALL OR CEILING SEE INSTRUCTIONS AND BUILDING CODES DO NOT CONNECT THIS UNIT TO A CHIMNEY FLUE SERVING ANOTHER APPLIANCE FUEL FOR USE WITH SOLID WOOD FUEL ONLY DO NOT USE GRATE OR ELEVATE FIRE BUILD WOOD FIRE DIRECTLY ON HEARTH WARNING RISK OF SMOKE SPILLAGE OPERATE ONLY WITH DOOR FULLY CLOSED REPLACE GLASS ONLY WITH CERAMIC GLASS DO NOT OVERFIRE IF HEATER OR CHIMNEY CONNECTORS GLOW YOU ARE OVERFIRING INSPECT AND CLEAN CHIMNEY FREQUENTLY UNDER CERTAIN CONDITIONS OF USE CREOSOTE BUILD UP MAY OCCUR RAPIDLY OPTIONAL LEGS IF TO BE INSTALLED WITH OPTIONAL LEGS LEGS MUST BE INSTALLED PRIOR TO OPERATION OPTIONAL BLOWER KIT 65 115V 60HZ 0 82 ROUTE CORD AWAY FROM UNIT DANGER RISK OF ELECTRICAL SHOCK DISCONNECT POWER BEFORE SERVICING UNIT PARALLEL PARALLELE CORNER COIN TESTED TESTE SELON UL1482 1996 ULC S627 00 MODEL MODELE 2100 POUR INSTALLATION ET UTILISATION CONFORMEMENT AUX INSTRUCTIONS DE WOLF STEEL LTEE RENSEIGNEZ VOUS AUPRES DES AUTORITES LOCALE
51. L APPLIANCE HAS COOLED DO NOT USE ABRASIVE CLEANERS Check your chimney and chimney connector for creosote and soot buildup weekly until a safe frequency for cleaning is established If accumulation is excessive disconnect the appliance and clean both the chimney and the appliance You may want to call a professional chimney sweep to clean them Both have to be cleaned at least once a year or as often as necessary Remove fibre baffles and clean above them once a year Replace any broken bricks 8 1 ASH REMOVAL PROCEDURES DISPOSAL ASHES RESULT IN FIRES DO DISCARD ASHES CARDBOARD BOXES DUMP IN BACK YARDS OR STORE IN GARAGES IF USING VACUUM TO CLEAN UP ASHES BE SURE THE ASHES ARE ENTIRELY COOLED USING A VACUUM TO CLEAN UP WARM ASHES COULD CAUSE A FIRE INSIDE THE VACUUM NEVER OPERATE YOUR APPLIANCE WITH THE GRATE COVER REMOVED FAILURE TO ACHIEVE A GOOD SEAL BETWEEN THE ASH OPENING ASH PLUG OR ASH WELL DOOR WILL RESULT IN AN OVER FIRE CONDITION THAT COULD CAUSE DAMAGE TO THE APPLIANCE Allow the ashes in your firebox to accumulate to a depth of two or three inches they tend to burn themselves up When the fire has burned down and cooled remove any excess ashes but leave an ash bed approximately 1 inch 25 4mm deep on the firebox bottom to help maintain a hot charcoal bed DISPOSAL OF ASHES Ashes should be placed in a metal container with a tight fitting lid The closed contain
52. N MONOXIDE DETECTORS 7 3 FUEL 7 4 LIGHTING FIRE 7 4 1 FLASH FIRE 7 5 1 EXTENDED FIRE 7 6 SMOKING MAINTENANCE 8 1 ASH REMOVAL PROCEDURES 8 1 1 ASH REMOVAL WITH ASH DRAWER 8 2 CREOSOTE FORMATION AND REMOVAL 8 3 RUNAWAY OR CHIMNEY FIRE 8 4 CHIMNEY CLEANING 8 5 GLASS REPLACEMENT 8 6 GASKET REPLACEMENT 8 7 CARE OF GLASS 8 8 WOOD REPLACEMENTS TROUBLESHOOTING WARRANTY 415 1464 04 21 15 4 o 0101 A 1 0 INSTALLATION OVERVIEW Draft see AIR CONTROL section Rating plate see RATING PLATE INFORMATION section Blower see Door see DOOR OPTIONAL BLOWER REMOVAL INSTALLATION INSTALLATION section section Handle see DOOR HANDLE INSTALLATION section Ash see ASH REMOVAL PROCEDURES section Outside air see OUTSIDE AIR section W415 1464 04 21 15 4 2 0 INTRODUCTION e THIS APPLIANCE IS HOT WHEN OPERATED AND CAN CAUSE SEVERE BURNS IF CONTACTED e CHANGES OR ALTERATIONS TO THIS APPLIANCE OR ITS CONTROLS CAN BE DANGEROUS AND IS PROHIBITED e Do not operate appliance before reading and understanding operating instructions Failure to operate appliance according to operating instructions could cause fire or injury e Before installing this appliance contact the local building or fire authority and follow their guidelines e This appliance must be installed by a qualified installer e Risk of burns The applianc
53. NDIE DE CHEMIN E OU DU DOMICILE NE FRAPPEZ PAS ET NE CLAQUEZ PAS LA PORTE N ENLEVEZ JAMAIS LA PORTE LORSQUE L APPAREIL EST CHAUD LOQUET DE POIGN E DE PORTE RONDELLE RONDELLE DE xd BLOCAGE CROU ESPACEUR DE PORTE NOTE Position du loquet de poign e de porte 415 1464 04 22 15 61 5 5 TUYAUX D AIR SECONDAIRE A En proc dant de l arri re vers l avant de la chambre de combustion SN JN Bg RE glissez y un tuyau d air secondaire puis ins rez le dans le trou comme illustr en A R p tez avec les autres tuyaux 00000000600000000040000 EP21LA S ILLUSTRE B Inserez chacun des tuyaux dans les trous opposes En orientant les trous du tuyau d air secondaire vers l avant alignez le tuyau avec e EA le support puis ins rez C EM la goupille fendue tel c qu illustr en B ics LEE Fix
54. NDUITS ET L ENCEINTE AFIN DE PROT GER LES PI CES EXPOS ES AUX INTEMP RIES CONTRE LA CORROSION NOUS CONSEILLONS QUE LE DESSUS DE L ENCEINTE SOIT PEINT AVEC UNE PEINTURE ANTIROUILLE NE REMPLISSEZ AUCUN ESPACE CHARPENT AUTOUR DU CONDUIT AVEC DE L ISOLANT OU TOU AUTRE MATERIAU L ISOLANT POSE DANS CET ESPACE POURRAIT CAUSER LES MATERIAUX COMBUSTIBLES AVOISINANTS SURCHAUFFER CONSERVEZ UN D GAGEMENT MINIMAL DE 2 TOUTES LES PI CES DU SYST ME DE CONDUITS EN TOUT TEMPS OMETTRE DE CONSERVER CE D GAGEMENT DE 2 CAUSERA UN INCENDIE NE REMPLISSEZ CET ESPACE AVEC AUCUN DE MATERIAU DES INSTRUCTIONS D TAILL ES SUR L INSTALLATION DU DESSUS DE L ENCEINTE DU COLLET DE SOLIN ET DU CHAPEAU SONT INCLUSES AVEC CES PIECES NE COUPEZ PAS DE CHEVRONS NI DE SOLIVES DE PLAFOND SANS AVOIR CONSULTE AU PR ALABLE LES AUTORIT S EN B TIMENT POUR VOUS ASSURER QUE L INT GRIT DE LA STRUCTURE N EST PAS COMPROMISE DES ESPACEURS COUPE FEU DOIVENT ETRE UTILISES LORSQUE LE SYSTEME DE CONDUITS TRAVERSE UN PLAFOND PLANCHER LA LONGUEUR TOTALE DE LA COURSE HORIZONTALE NE DEVRAIT PAS EXC DER 40 DE LA HAUTEUR DE LA CHEMIN E PARTIR DU DESSUS DU PO LE TOUTES LES COURSES HORIZONTALES DOIVENT AVOIR UNE PENTE MINIMALE VERS LE HAUT DE 1 4 PAR PIED ET TOUS LES RACCORDEMENTS DOIVENT TRE SCELL S ET FIX S PAR TROIS VIS AUTOPERCEUSES ESPAC ES GALEMENT UN TUYAU DE RACCORDEMENT NON ISOL NE DOIT PAS TRAVERSER U GRENIER UN E
55. NTRETOIT UN PLACARD OU AUTRE ENDROIT DISSIMUL OU TRAVERSER UN PLANCHER UN PLAFOND UN MUR OU UNE CLOISON OU TOUTE AUTRE CONSTRUCTION COMBUSTIBLE N UTILISEZ AUCUN MAT RIAU DE FORTUNE DURANT L INSTALLATION Votre appareil peut tre raccord une chemin e de magonnerie ou pr fabriqu e Si vous utilisez une chemin e pr fabriqu e elle doit se conformer aux normes ULCS629 au Canada ou UL103 U Elle doit donc tre de type 6 HT 2100 F est extr mement important qu elle soit install e selon les sp cifications du fa bricant Les directives d installations du fabricant et les d gagements sp cifi s doivent toujours tre respect s en fonction des normes locales et nationales Conformez vous aux codes d installation CSA B365 et CSA C22 1 au Canada et aux codes ANSI NFPA 70 et ANSI NFPA 211 aux tats Unis La chemin e et le conduit de raccordement doivent tre gard s en bonne condition et propres 415 1464 04 22 15 4 1 1 INSTALLATION DE LA CHEMIN E Votre conduit de raccordement et votre chemin e doivent avoir le m me diam tre que le tuyau d chappement de l appareil Le tuyau de l appareil doit tre en acier alumini ou en acier lamin froid d une paisseur minimale de calibre 24 est strictement interdit d utiliser de l acier galvanis 53 Un conduit de raccordement paroi simple de 6 152 4mm de diam tre servant raccorder l appareil la chemin e doit tre install avec l
56. Placez le joint d tanch it dans la rainure par dessus la silicone 3 Mettez la vitre sur la porte R installez les pattes de retenue NOTE Pour les dimensions l paisseur et les sp cifications de la vitre de remplacement voir la sec tion RECHANGES REMPLACEMENT DES JOINTS D TANCH IT la fin de chaque saison de chauffage v rifiez s il n y a pas de gondolage ou de d t rioration de l cran du collecteur et du joint sous le collecteur Remplacez si n cessaire Les deux sont fix s au collecteur l aide de vis m tal L cran et le joint de fibre de 1 8 3 2 mm sont disponibles chez votre d taillant Wolf Steel It e V rifiez aussi que le joint de la porte n est pas d t rior ou l che Remplacez avec un joint de fibre de verre haute densit de 3 8 9 5 mm si n cessaire Le joint et l cran du collecteur au dessus de la porte devraient tre inspect s et remplac s s ils sont d t ri ores NOTE Ne faites pas fonctionner l appareil si du collecteur ou le deflecteur en fibre est deteri ore ou manquant W415 1464 04 22 15 74 8 7 SOINS DE LA VITRE Si vous ne nettoyez pas les d p ts r guli rement la vitre risque de rester marqu e en permanence Normalement un feu tr s chaud maintiendra la vitre propre Les raisons les plus fr quentes pour lesquelles la vitre se salit sont trop UNE SURFACE VITREE CHAUDE peu de combustible est utilis pour r chauffer suff
57. RE APPAREIL FAIRE FONCTIONNER CET APPAREIL AVEC LES PORTES OUVERTES OU ENTROUVERTES CR E UN RISQUE D INCENDIE DE CHEMINEE OU DU DOMICILE CET APPAREIL AU BOIS POSS DE UN TAUX MINIMAL DE COMBUSTION TABLI PAR LE FABRICANT QUI NE DOIT PAS TRE MODIFI LES REGLEMENTS F D RAUX INTERDISENT EN TATS UNIS DE MODIFIER CE R GLAGE OU D UTILISER CET APPAREIL DE CHAUFFAGE D UNE MANI RE ALLANT L ENCONTRE DES INSTRUCTIONS DE FONCTIONNEMENT CONTENUES DANS CE MANUEL Votre appareil Timberwolf certifi aux normes EPA est un appareil de haute technologie concu selon les principes technologiques les plus avanc s Cet appareil est extr mement herm tique Le s premier s feu x de l appareil sera seront difficile s partir et maintenir tout en produisant qu un peu de chaleur Ceci est le r sultat de l humidit manant des briques r fractaires Durant la p riode de rodage les premiers 2 ou 3 feux ne faites que des petits feux en utilisant du bois d allumage cela permettra la brique de se conditionner Ne vous inqui tez pas si de petites fissures apparaissent dans les briques r fractaires Cela est normal et ne pose aucun danger la s curit La peinture peut galement produire de l g res manations pendant les premiers feux cause du processus de cuisson vous devrez ouvrir une porte ou une fen tre pour chasser les odeurs l allumage un feu vif est requis Placez des morceaux de papier grossi rement chiffonn
58. S DU BATIMENT OU DU SERVICE DES INCENDIES AU SUJET DES RESTRICTIONS ET DES INSPECTIONS D INSTALLATION DANS VOTRE REGION HAUTEUR DE PLAFOND MINIMAL 7 2 13mm PROLONGEMENT D ATRE PROTECTION DU PLANCHER COMBUSTIBLE SI INSTALLE SUR UN PLANCHER COMBUSTIBLE L APPAREIL DOIT TRE PLACE SUR UNE PLAQUE PROTECTRICE INCOMBUSTIBLE S TENDANT SUR 18 455mm L AVANT ET 8 205mm L ARRI RE ET SUR LES COTES TYPE DE CHIMNEE CHEMINEE RESIDENTIELLE DE 6 DE DIAMETRE 152 mm HOMOLOGUEE UL 108HT RACCORD DE CHEMINEE DIAMETRE DE 6 152mm DAGIER DE CALIBRE 24 MINIMUM 18 455mm DE DEGAGEMENT MINIMAL ENTRE LE RACCORD HORIZONTAL ET LE PLAFOND NE RIEN ENTREPOSER SOUS L APPAREIL DES M THODES SP CIALES SONT REQUISES LORSQUE UNE G EMIN E TRAVERSE UN MUR OU UN PLAFOND VOIR LES INSTRUCTIONSIETLESICODES DU NE PAS RACCORDER LA CHEMIN E D UN AUTRE APPAREIL COMBUSTIBLE POUR USAGE AVEC LE BOIS SEULEMENT N UTIFISEZ PAS DEICHENET OU NE SUR LEVEZ PAS LE BOIS PR PAREZ LE FEU DIRECTEMENT SURIZATRE AVERTISSEMENT RISQUE D CHAPPEMENT DE FUM E TENIRIEAIRORTE FERM E LORSQUE LE POELE FONCTIONNE REMPLACEZ LA VITRE PAR UNE VITRE EN C RAMIQUE SEULEMENT NE SURCHAUFFEZ PAS EAPPAREIL SI L APPAREIL OU LES RACCORDS ROUGEOIENT L APPAREIL SURGHAUFEESINSRECTEZ NETTOYEZ LACHEMINEE FR QUEMMENT DANS CERTAINES CONDITIONS eg D P TS DE CREOSOTE PEUVENT SE FORMER RAPIDEMENT PATTES OPTIONNELLES SILES PATTES OPT
59. S X 4 260 00 4 415 1464 04 22 15 EP21LA O TY lt 78 10 0 GUIDE DE D PANNAGE LORSQUE VOUS V RIFIEZ DES CONNEXIONS QUE VOUS INSTALLEZ DES FILS DE D RIVATION POUR EFFECTUER DES TESTS UNIQUEMENT OU QUE VOUS REMPLACEZ DES COMPOSANTS DEBRANCHEZ L APPAREIL DU RECEPTACLE AFIN D EVITER LES CHOCS ELECTRIQUES OU DES DOMMAGES AUX COMPOSANTS PROBLEME SOLUTIONS Le feu ne s allume pas Pas assez de bois d allumage de papier Ajoutez en Pas assez d air Assurez vous que le contr le d air est compl tement ouvert d air froid Br lez un morceau de papier journal pour cr er un tirage Utilisez du bois bien sec avec de 20 d humidit Conduit obstru Inspectez la chemin e Pr sence de fum e Blocage d air froid Br lez un morceau de papier journal pour cr er un lorsque la porte est tirage ouverte Tirage insuffisant Ajoutez des conduits Laissez l air se stabiliser avant d ouvrir la porte Assurez vous que les d flecteurs sont bien positionn s Pression n gative Ouvrez une fen tre situ e pr s de l appareil Une odeur se d gage de Cuisson de la peinture Voir la section INSTRUCTIONS G N RALES l appareil L appareil ne devient pas Le bois a plus de 20 d humidit suffisamment chaud Tirage insuffisant Ajoutez des conduits Pas assez d air Assurez vous que le contr le d air est compl tement
60. STEM AT ALL TIMES THIS EXCLUDES THE CHIMNEY CONNECTION FAILURE TO MAINTAIN THIS 2 50 8mm AIR CLEARANCE WILL CAUSE A STRUCTURE FIRE NEVER FILL THIS SPACE WITH ANY TYPE OF MATERIAL DETAILED INSTRUCTIONS FOR INSTALLATION OF THE CHASE TOP STORM COLLAR AND TERMINATION CAP ARE PACKAGED WITH THESE PARTS DO NOT CUT RAFTERS OR CEILING JOISTS WITHOUT FIRST CONSULTING A BUILDING OFFICIAL TO ENSURE STRUCTURAL INTEGRITY IS NOT COMPROMISED FIRESTOP SPACERS MUST BE USED WHENEVER THE CHIMNEY PENETRATES A CEILING FLOOR AREA THE TOTAL HORIZONTAL VENT LENGTH SHOULD NOT EXCEED 40 OF THE CHIMNEY HEIGHT ABOVE THE APPLIANCE ALL HORIZONTAL SMOKE PIPE MUST SLOPE SLIGHTLY UPWARDS A MINIMUM OF 1 4 6 4mm PER FOOT AND ALL CONNECTIONS MUST BE TIGHT AND SECURED BY THREE SHEET METAL SCREWS EQUALLY SPACED AN UNINSULATED SMOKE PIPE SHALL NOT PASS THROUGH AN ATTIC ROOF SPACE CLOSET OR SIMILAR CONCEALED SPACE OR THROUGH A FLOOR CEILING WALL OR PARTITION OR ANY COMBUSTIBLE CONSTRUCTIONS DO NOT USE ANY MAKESHIFT MATERIALS DURING INSTALLATION Your appliance may be connected to a factory built or masonry chimney If you are using a factory built chimney it must comply with ULCS629 Canada or UL103 USA standards It must therefore be a 6 152 4mm HT 2100 F chimney It is extremely important that it be installed according to the manufacturer s specifications The manufacturer s installation instructions and specified clearances
61. TE Largeur minimale de 62 1625 6 mm profondeur minimale de 32 812 8 mm W415 1464 04 22 15 50 3 4 3 9 PROTECTION DU PLANCHER PROTECTEUR DES BRAISES L appareil doit tre install sur un protecteur thermique incombustible se prolongeant sur le devant les c t s et l arri re de l appareil selon les exigences minimales ci dessous NOTE Une protection de plancher est requise pour prot ger des tincelles et de la cendre mais non pour limiter la temp rature du plancher de la chaleur rayonnante de l appareil Cet appareil a t concu et test de sorte que le plancher ne surchauffera pas m me sans protection EE I AVANT C T S J ARRI RE K VENT L CANADA 18 457 2mm 8 203 2mm 8 203 2mm i EA 167 406 4 8 203 2mm 8 203 2 2 50 8mm 99 18 NOTE Si une section de conduit de raccordement horizontal est utilis e la protection de plancher doit se prolonger sous le conduit de raccordement et 2 50 8 mm de chaque c t AIR EXT RIEUR Les conditions suivantes indiquent que l air d ext rieur pourrait tre n cessaire pout la fonctionnement de appareil Lorsque l appareil fonctionne le bois br le mal de la fum e s chappe des refoulements se pro duisent et le tirage est irr gulier En hiver les fen tres pr sentent une condensation excessive Les conditions mentionn es ci dessus s am li
62. UR CHIMNEY SYSTEM THIS DAMAGE CAN ONLY BE REPAIRED BY REPLACING THE DAMAGED COMPONENT PARTS CHIMNEY FIRES ARE NOT COVERED BY THE LIFETIME LIMITED WARRANTY Runaway fires can be the result of three major factors Using incorrect fuel or small fuel pieces which would normally be used as kindling e Leaving the door ajar too long and creating extreme temperatures as the air rushes in the open door e Burning your appliance with the ash plug not securely seated SOLUTIONS e Do not burn treated or processed wood coal charcoal coloured paper or cardboard Be careful not to over fire the appliance by leaving the door open too long after initial start up A thermometer on the chimney connector and or appliance top helps e Always operate the appliance with the ash plug properly installed IN CASE OF A CHIMNEY FIRE e Have well understood plan for evacuation and a place outside for everyone to meet Prepare to evacuate to ensure everyone s safety e Close air control on appliance Call local fire department Have a fire extinguisher handy Contact local authorities for further information on how to handle a chimney fire e After the fire is out clean and inspect the chimney for stress and cracks prior to lighting another fire Also check combustibles around the chimney and the roof 85 1 CHIMNEY CLEANING Both the chimney and the appliance must be inspected and cleaned if necessary at least once a year
63. US INSTALLEZ LE W41 TIROIR CENDRES OPTIONNEL Pour viter que l appareil soit endommag lors du trans port il a t boulonn la palette et doit tre d boulonn de celle ci avant d tre install NOTE Si vous installez le tiroir cendres optionnel voir la section ENSEMBLE TIROIR CENDRES OP TIONNEL EP20LAD avant l installation de l cran thermique et des pattes NOTE Les pattes peuvent n cessiter un ajustement pour s aligner correctement avec les trous de l cran ther mique A Passez le boulon dans le trou de la patte B Glissez la rondelle et la rondelle de blocage sur le boulon Vissez l crou sur le boulon un ou deux tours puis glissez la patte dans la fente de l appareil comme illustr R p tez pour les autres pattes NOTE Les boulons doivent tre serr s avant d installer l cran thermique C Ins rez l cran thermique dans les quatre boulons et fixez le l aide des crous restants D Soulevez l appareil et d posez PLAQUE le doucement sur ses quatre 4 7 pattes Ne faites pas pivoter POIN ONNEE l appareil sur ses pattes car VOIR AVERTISSE risque de les endommager MENT CI DESSUS Le logo peut tre plac diff rents endroits
64. abrasive and chemical cleaners nor chipping on porcelain enamel parts nor any venting components used in the installation of the appliance In the first year only this warranty extends to the repair or replacement of warranted parts which are defective in material or workmanship provided that the product has been operated in accordance with the operation instructions and under normal conditions After the first year with respect to the TIMBERWOLF S Limited Warranty Wolf Steel may at its discretion fully discharge all obligations with respect to this warranty by refunding to the original warranted purchaser the wholesale price of any warranted but defective parts After the first year Wolf Steel Ltd will not be responsible for installation labour or any other costs or expenses related to the reinstallation of a warranted part and such expenses are not covered by this warranty Notwithstanding any provisions contained in the TIMBERWOLF S Limited Warranty Wolf Steel s responsibility under this warranty is defined as above and it shall not in any event extend to any incidental consequential or indirect damages This warranty defines the obligations and liability of Wolf Steel with respect to the TIMBERWOLF appliance and any other warranties expressed or implied with respect to this product its components or accessories are excluded Wolf Steel neither assumes nor authorizes any third party to assume on its behalf any other liabilities with respec
65. ailed information AIR CONTROL THIS WOOD APPLIANCE HAS MANUFACTURER SET MINIMUM LOW BURN RATE THAT MUST NOT BE ALTERED IT IS AGAINST FEDERAL REGULATIONS IN THE UNITED STATES TO ALTER THIS SETTING OR OTHERWISE OPERATE THIS WOOD APPLIANCE IN A MANNER INCONSISTENT WITH OPERATING INSTRUCTIONS IN THIS MANUAL Draft is the force which moves air from the firebox up through the chimney The amount of draft in your chim ney depends on the length and diameter of chimney local geography nearby obstructions and other factors including the amount of heat generated by the fire which can be measured by an appliance thermometer AIR CONTROL Adjusting the air control all the way to the left reduces the temperature The draft can be adjusted from low to high by moving the handle from left to right po Inadequate draft may cause back puffing into the room through the appliance and chimney connector points and may cause plugging of the chimney Too much draft may cause an excessive temperature in the appliance glowing red appliance parts or chimney connectors or an uncontrollable burn which can lead to a chimney fire or permanent damage to the appliance Do not operate your appliance for longer than 30 minutes with the draft control on HIGH fully open W415 1464 04 21 15 29 7 5 FIRE EXTINGUISHERS SMOKE amp CARBON MONOXIDE DETECTORS All homes with a solid fuel burning appliance should have at least one fi
66. ance is cool remove the door and place it face down on a soft surface Be careful not to scratch the paint B Remove the 5 screws securing the glass retainers C Remove all broken glass D Cut the 3 4 19 1mm flat gasket into 3 1 2 88 9mm lengths and affix to glass retainers as illustrated ensure the gasket extends past the ends of the retainers by 1 4 6 4mm E Apply small beads of silicone in the gasket groove as shown Place the gasket in the gasket groove top of the silicone 3 Place the glass the door Re install the glass retainers NOTE For replacement glass size thickness and specifications see REPLACEMENTS section GASKET REPLACEMENT At the end of each burning season inspect the shield and gasket below the manifold for warping or deterioration Replace if necessary Both are held to the manifold with machine screws The shield and the 1 8 8 2mm fibre cloth gasket are available from your Wolf Steel Ltd dealer At this time also check that the door gasket is not worn or loose Replace with 3 8 9 5mm high density fibreglass rope if necessary The airwash gasket and shield above the door should also be inspected and replaced if deteriorated NOTE Do not operate appliance if the manifold shield or fibre baffle is deteriorated or missing W415 1464 04 21 15 34 CARE GLASS If the glass is not kept clean permanent discolouration and or blemi
67. areil avant d avoir lu et compris les instructions d op ration Omettre d utiliser l appareil selon les instructions d op ration pourrait causer un incendie ou des blessures Avant d installer cet appareil contactez les autorit s locales du b timent ou le service des incendies et suivez leurs directives Cet appareil doit tre install par un installateur qualifi Risque de br lures L appareil doit tre teint et refroidi avant d effectuer un entretien Ne faites pas fonctionner tant que tous les composants ne sont pas compl tement install s Ne laissez pas l appareil chauffer au point o des parties deviennent rougeoyantes N installez pas de composants endommag s ou incomplets ni des composants substituts Risque de coupures et d raflures Portez des gants protecteurs et des lunettes de s curit lors de l installation Les bordures des pi ces de m tal peuvent tre coupantes Les enfants et les adultes devraient tre inform s des dangers que posent les temp ratures de surface lev es et se tenir distance afin d viter des br lures ou que leurs v tements ne s enflamment Surveillez attentivement les jeunes enfants lorsqu ils sont dans la m me pi ce que l appareil Les jeunes enfants et autres sont plus risque de contacts accidentels causant des br lures Une barri re physique est conseill e lorsque qu il y a des individus risque dans la maison Pour emp cher l acc s un appareil ou un po le installez u
68. ast A Air control may need to be adjusted down Check to see ash plug is properly seated if equipped Check door gasket for adequate seal Wood may be extremely dry Dirty glass A Air control may be closed too far Burn hotter smaller fires Use well seasoned wood with 20 moisture content Blower does not run Appliance may not be up to temperature Ensure blower has power 42 14C 415 1464 04 21 15 39 11 0 WARRANTY TIMBERWOLF products are manufactured under the strict Standard of the World Recognized ISO 9001 2008 Quality Assurance Certificate TIMBERWOLF products are designed with superior components and materials assembled by trained craftsmen who take great pride in their work The complete appliance is thoroughly inspected by a qualified technician before packaging to ensure that you the customer receives the quality product that you expect from TIMBERWOLF TIMBERWOLF WOOD APPLIANCE LIMITED WARRANTY The following materials and workmanship in your new TIMBERWOLF appliance are warranted against defects as defined below The combustion chamber is warranted against defects for a period of 25 years The secondary air tubes are warranted against defects for a period of five years All other wearable parts and electrical components such as blowers thermal switches switches wiring rheostats firebrick ceramic glass thermal breakage only fibre baffles and gasketing are covered and Wolf Steel wi
69. bien nettoy e mettez le nouveau couvercle de la chute cendres fourni sur l ouverture ij e Retirez soigneusement la plaque poin onn e de l cran ther An E EN mique en cassant les petites pattes p e D pliez les quatre pattes un angle de 90 par rapport l cran thermique B XS e Alignez les fentes du bo tier du tiroir cendres avec les quatre pattes Fixez en place l aide des quatre vis fournies PATES e Fixez l cran thermique et le boitier du tiroir cendres l appareil l aide des crous que vous avez enlev s l tape 2 e Ins rez le tiroir cendres dans le compartiment cendres 415 1464 04 22 15 66 6 3 ENSEMBLE TIROIR CENDRES EP20PAD SI LE JOINT ENTRE L OUVERTURE DE LA CHUTE CENDRES ET LE COUVERCLE N EST PAS TANCHE CELA ENTRA NERA UNE SURCHAUFFE POUVANT CAUSER DES DOMMAGES A L APPAREIL Cet appareil a t concu pour recevoir un tiroir cendres optionnel Cet ensemble vous permettra de disposer ais ment des cendres NOTE Nous vous conseillons d installer les rails sur la base du pi destal avant d installer le pi destal au caisson e Si l appareil a d j t utilis il doit tre refroidi et vous devez enlever les cen dres pour acc der au couvercle de la chute cendres Si le pi destal est install avec l ouverture situ e l arri re vous devrez coucher l appareil sur le dos retirer le pi destal e
70. bustible N utilisez pas des b ches artificielles contenant des additifs comme de la paraffine de la cire des liants etc Ne br lez jamais plus de deux b ches artificielles la fois FAIRE NE PAS FAIRE Faire un feu chaud e Retirer les cendres imm diatement Laissez les saccumuler e Utiliser du bois sec seulement avec de 20 d humidit sur une paisseur d au moins un pouce Une bonne couche e Plusieurs morceaux de dimensions moyennes sont de cendres favorise une attis e qui br le mieux et qui dure pr f rables quelques gros morceaux plus longtemps e Nettoyer la chemin e r guli rement Br ler du bois humide avec plus de 2096 d humidit e R alimenter fr quemment en utilisant des morceaux de Fermer la porte pr matur ment ou fermer le contr le de dimension moyenne combustion trop rapidement Bien ajuster le contr le de combustion pour une perfor Br ler un gros morceau de bois plut t que deux ou trois mance optimale morceaux plus petits de dimensions plus raisonnables e Br ler continuellement un r glage trop bas Si la vitre de la porte est constamment noircie cela signifie que la temp ra ture de la chambre de combustion est trop basse 87 1C 415 1464 04 22 15 76 9 0 RECHANGES Contactez votre d taillant ou le fabricant pour les questions concernant les prix et la disponibilit des pi ces de rechange Normalement toutes les pi ces peuvent tre command es chez votre d
71. ce draft or smoking problems you as NF Pellet Specialists or who certified in Canada by may need to open a door a window or otherwise provide some method of supplying CERTIFIED Wood Energy Technical ang combustion air to the appliance If you experience smoking problems you may been to open a door a window or otherwise provide some method of supplying combustion air to the appliance CALIFORNIA PROP 65 WARNING Use of this product may produce smoke which contains chemicals known to the State of California to cause cancer birth defects or other reproductive harm W415 1464 04 21 15 2 6 RATING PLATE INFORMATION LISTED SOLID FUEL BURNING SPACE HEATER For rating plate location see 5 POELE A COMBUSTIBLE SOLIDE HOMOLOGUE INSTALLATION OVERVIEW section This illustration is for reference only Refer to the rating plate on the appliance for accurate informa tion NOTE The rating plate must remain with the appliance at all times It must not be removed Lied By eegen UA 0 2 Tee aba sisia REPORT NUM RO RAPPORT 415 5 02 2 INSTALLAND USE ONLY INACCORDANCE WITH WOLF STEEL LTD S INSTRUCTIONS CONTACT LOCAL BUILDING OR FIRE OFFICIALS ABOUT RESTRICTIONS AND INSTALLATION INSPECTION IN YOUR AREA MINIMUM CEILING HEIGHT 7FT 2 13 HEARTH EXTENSION COMBUSTIBLE FLOOR PROTECTION IF INSTALLED ON A COMBUSTIBLE FLOOR UN
72. de la peinture ou du diluant de solvants de plastique des mat riaux contenant de l amiante des d bris de construction des traverses de chemin de fer ou de bois trait s u fumier ou des restes d animaux du bois de gr ve impr gn de sel ou des mat riaux sal s du bois non s ch de charbon de papiers de couleur de cartons des contreplaqu s ou des panneaux de particules Syst me de qualit certifi Portland Oregon USA US 9 a a 1 a OMNI Test Laboratories Inc Hearth Patio A Barbecue Association Ne laissez pas l appareil chauffer au point des parties deviennent rouge GARDEZ LA TEMP RATURE SUR LE DESSUS DE L APPAREIL SOUS 700 371 C Toute tentative de d passer les d bits maximaux de chaleur tels que mentionn s dans les sp cifications de conception pourrait provoquer la distorsion de l acier et causer des dommages Wolf Steel Ltd 24 Napoleon Rd Barrie ON L4M 0G8 Canada 103 Miller Drive Crittenden Kentucky USA 41030 T l phone 705 721 1212 T l copieur 705 722 6031 www timberwolffireplaces com ask timberwolffireplaces com 10 00 1 14 415 1464 04 22 15 42 TABLE DES MATI RES 1 0 VUE D ENSEMBLE DE L INSTALLATION 43 2 0 INTRODUCTION 44 2 1 DIMENSIONS 45 2 2 SP CIFICATIONS 45 2 3 IN
73. de vos activit s familiales de fa on que suffisamment de braises soient disponibles pour allumer la charge suivante Le soir chargez votre appareil au moins une demi heure avant de vous coucher pour vous assurer que le feu soit suffisamment chaud pour fermer le contr le de combustion pour une combustion nocturne Ne br lez que du bois bien sec avec moins de 20 d humidit ll produit plus de chaleur et moins de suie et de cr osote Ne br lez pas le bois qui a s journ dans l eau de mer le contenu en sel peut produire un acide qui gruge le m tal Lorsque vous rechargez l appareil ouvrez la porte lentement afin d viter les refoulements de fum e Lorsque vous alimentez le feu portez de longs gants protecteurs gants pour BBQ Puisque la combustion se fait l avant ces appareils sont propres et efficaces mais ils deviennent aussi tr s chauds et les gants sont alors tr s utiles Gardez une petite pelle en acier proximit elle peut tre utilis e comme tisonnier ou pour enlever les cendres N entreposez pas le bois moins de trois pieds 1 m de W415 1464 04 22 15 l appareil 70 ALLUMER UN FEU 7 5 1 FEU CLAIR Un feu clair est un petit feu qui br le rapidement quand vous n avez pas besoin de beaucoup de chaleur Une fois que votre bois d allumage est bien allum chargez trois buches par dessus de fa on tr s l che Faites bruler avec le contr le de combustion pleinement ou
74. design specifications can result in steel distortion and damage Wolf Steel Ltd 24 Napoleon Rd Barrie ON LAM 0G8 Canada 103 Miller Drive Crittenden Kentucky USA 41030 Phone 705 721 1212 Fax 705 722 6031 www timberwolffireplaces com ask timberwolffireplaces com 10 00 1 14 415 1464 04 21 15 3 0 4 0 5 0 6 0 7 0 8 0 9 0 10 0 11 0 NOTE Changes other than editorial are denoted by vertical line in the margin TABLE OF CONTENTS INSTALLATION OVERVIEW INTRODUCTION 21 DIMENSIONS 2 2 SPECIFICATIONS 2 3 GENERAL INSTRUCTIONS 2 4 GENERAL INFORMATION 2 5 CALIFORNIA PROP 65 WARNING 2 6 RATING PLATE INFORMATION PRE INSTALLATION PREPARATION 3 1 APPLIANCE PLACEMENT 3 2 MINIMUM CLEARANCE TO COMBUSTIBLES 3 3 ALCOVE INSTALLATION 3 4 FLOOR PROTECTION 3 5 OUTSIDE AIR INSTALLATION 4 1 CHIMNEY 4 1 1 CHIMNEY CONNECTION 4 1 2 ADDING SECTIONS 4 1 3 TYPICAL THROUGH THE CEILING 4 1 4 TYPICAL THROUGH THE WALL 4 1 5 TYPICAL EXISTING MASONRY FINISHING 5 1 LEG INSTALLATION 5 2 PEDESTAL INSTALLATION 5 3 DOOR REMOVAL 5 4 DOOR HANDLE INSTALLATION 5 5 SECONDARY AIR TUBES 5 6 BRICK AND BAFFLE INSTALLATION 5 7 ASH LIP INSTALLATION OPTIONAL INSTALLATION 6 1 BLOWER KIT INSTALLATION 6 2 ASH DRAWER KIT EP20LAD 6 3 ASH PAN KIT EP20PAD OPERATION 7 1 OPTIMUM BURN METHOD 7 2 AIR CONTROL 7 5 FIRE EXTINGUISHERS SMOKE amp CARBO
75. doit tre inspect e et r par e au besoin de pr f rence par un ramoneur ou un ma on qualifi 86 1 415 1464 04 22 15 6 5 6 6 73 REMPLACEMENT DE LA VITRE N UTILISEZ PAS DE MATERIAUX DE SUBSTITUTION LA VITRE PEUT ETRE CHAUDE NE TOUCHEZ PAS LA VITRE JUSQU A CE QU ELLE AIT REFROIDI USEZ DE PRUDENCE LORSQUE VOUS ENLEVEZ ET JETEZ DES DEBRIS DE VERREOU DES COMPOSANTS ENDOMMAGES ASSUREZ VOUS D ASPIRER TOUS LES DEBRIS DEVERRE A L INTERIEUR DE L APPAREIL AVANT DE LE FAIRE FONCTIONNER NE FRAPPEZ PAS NE CLAQUEZ PAS ET N EGRATIGNEZ PAS LA PORTE VITREE NE FAITES PAS FONCTIONNER L APPAREIL LORSQUE LA PORTE VITREE EST ENLEVEE FISSUREE BRISEE OU EGRATIGNEE 56 2 Une fois que l appareil est refroidi ouvrez la porte et d posez le cadre de porte en prenant soin de pas gratigner la peinture B Retirez les 5 vis servant fixer les pattes de retenue C Enlevez toute la vitre bris e Coupez le joint d tanch it de 3 4 19 1 mm Ale morceaux de 3 1 2 66 9 et fixez les aux pattes de retenue tel qu illustr Assurez vous que chaque morceau d passe les pattes de retenue de 1 4 6 4 mm Appliquez des petits joints de silicone dans qui accueille le joint d tanch it tel qu illustr JOINT D TANCH IT DE 14 POUR VITRE JOINT D TANCH IT DE Ye POUR PORTE F
76. e being driven out of the fire brick During the break in period the first 2 or 3 fires create only small fires using kindling this will allow the firebrick to cure Do not be alarmed if small hairline cracks develop in the firebrick This is a normal occurrence and does not pose a safety hazard The paint may also smell a little for the first few fires as it cures and you may wish to open a door or window to alleviate the smell To start a brisk fire is required Place loosely crumpled paper on the floor of the appliance and cover with dry kindling Open the air control fully by sliding control all the way to the right Light the paper and leave the door slightly ajar 17 25 4mm until all kindling is burning To maintain a brisk fire a hot coal bed must be established and sustained Slowly add larger wood 2x4 size pieces Lay the pieces lengthwise from side to side in the hot coal bed with a shallow trench between so that the primary air can flow directly into this trench and ignite the fuel above When the fire seems to be at its peak medium sized logs may be added Once these logs have caught fire carefully close the door Closing the door too quickly after refueling will reduce the firebox temperature and result in an unsatisfactory burn Remember it is more efficient to burn medium sized wood briskly and refuel frequently than to load the appliance with large logs that result in a smouldering inefficient fire and dirty glass As soon a
77. e couvercle Nous vous conseillons d utiliser un tisonnier e Ratissez les cendres exc dentaires dans le tiroir cendres remplissez pas trop le tiroir cendres Le niveau des cendres doit pas d passer hauteur des c t s du tiroir e Avant de retirer le tiroir assurez vous que la r gion autour de l ouverture de la chute cendres est propre Cognez l g rement sur les c t s de l ouverture pour d loger les cendres r siduelles Remettez le couvercle de la chute cendres sur l ouverture Ne faites fonctionner l appareil qu avec le couvercle de la chute cen dres bien install 415 1464 04 22 15 12 8 2 FORMATION DE LA 5 Lorsque le bois br le lentement il produit du goudron et autres vapeurs organiques qui se combinant la vapeur d eau vacu e forme la creosote Ces vapeurs se condensent dans le conduit relativement froid de la chemin e d un appareil br lant lentement et lorsqu elle prend feu la creosote produit un feu extr mement chaud Par cons quent le tuyau de raccordement gaine de chemin e et la chemin e devraient tre inspect s mensuellement pendant la saison de chauffage afin de d terminer si une accumulation s est produite L accumulation de cr osote doit tre enlev e pour r duire le risque d un feu de chemin e 84 1 FEU DE CHEMIN E O FEU HORS CONTR LE UN FEU DE CHEMIN E PEUT ENDOMMAGER VOTRE CHEMIN E DE FA ON PERMANENTE
78. e should be turned off and cooled before servicing Donot operate without fully assembling all components e Do not let the appliance become hot enough for any part to glow red e Do not install damaged incomplete or substitute components e Risk of cuts and abrasions Wear protective gloves and safety glasses during installation Sheet metal edges may be sharp e Children and adults should be alerted to the hazards of high surface temperature and should stay away to avoid burns or clothing ignition e Young children should be carefully supervised when they the same room as the appliance Toddlers young children and others may be susceptible to accidental contact burns A physical barrier is recommended if there are at risk individuals in the house To restrict access to an appliance or stove install an adjustable safety gate to keep toddlers young children and other at risk individuals out of the room and away from hot surfaces e Clothing or other flammable material should not be placed on or near the appliance Objects placed in front of the appliance must be kept a minimum of 48 1219 2mm away from the front face of the appliance e Due to high temperatures the appliance should be located out of traffic and away from furniture and draperies e Ensure you have incorporated adequate safety measures to protect infants toddlers from touching hot surfaces e Even after the appliance is out the glass and or screen will remain h
79. een made on this ap Check that the thermal pliance to install an optional blower kit switch bracket Is EPT70 that comes complete with a vari Positioned as illustrated able speed switch to turn the blower ON OFF as well as adjusting the blower speed A Ensure the thermal disc bracket is in the correct position B Remove the knock out from the back of the appliance C Install the blower and housing as shown using the 4 screws supplied D Loosen the thermal disc bracket 2 screws and slide the bracket until the thermal disc is touching the rear of the firebox and secure EP21LA S MODEL ILLUSTRATED W415 1464 04 21 15 25 6 2 ASH DRAWER KIT EP20LAD FAILURE TO ACHIEVE GOOD SEAL BETWEEN THE ASH OPENING AND ASH PLUG WILL RESULT IN AN OVER FIRE CONDITION THAT COULD CAUSE DAMAGE TO THE APPLIANCE Provisions have been made on the appliance to install an optional ash drawer kit The kit allows for convenient removal of excess ash e If the appliance has been previously operated the appliance must be cold and the ashes must be removed in order to access the ash plug NOTE Place the ash drawer from the kit underneath the appliance to catch falling ashes during the installation e From the underside of the appliance remove the nuts that secures the heat shield and the ash opening cover plate e Remove the small light weight brick that is covering the ash opening and discard Itis important t
80. ep fuel back from the glass If coals are to accumulate on the front lip there is a chance they will fall out when the door is opened Loosely stacked wood burns quicker than a tightly packed load Wood burns in cycles rather than giving a steady output of heat It is best to plan these cycles around your household routine so that only enough coals are left to start the next load In the evening load your appliance at least a half hour before bed to ensure a good fire hot enough to close the draft control for an overnight burn Burn only dry seasoned wood with 20 moisture content It produces more heat and less soot or creosote Do not burn ocean beach wood Its salt content can produce a metal eating acid When refueling open the door slowly to prevent smoke spillage Use a pair of long gloves barbecue gloves when feeding the fire Because these appliances burn at the front they are clean and efficient but they are also very hot and gloves are useful Keep a small steel shovel nearby to use as a poker and to remove ashes Do not store the wood within 3 feet 1m of the appliance 7 4 LIGHTING A FIRE 7 4 1 FLASH FIRE A flash fire is a small fire burned quickly when you don t need much heat After your kindling has caught load at least 3 pieces of wood stacked loosely Burn with the draft control fully open or closed only slightly mei Ecran 93 1 W415 1464 04 21 15 30 7 5 1 EXTENDED FIRE Load your large
81. er of ashes should be placed on a non combustible floor or ground well away from all combustible materials pending final disposal If the ashes are disposed of by burial in soil or otherwise locally dispersed they should be retained in the closed container until all cinders have thoroughly cooled 8 1 1 ASH REMOVAL WITH ASH DRAWER e To remove the ashes clear the ash away from the ash plug e Remove the ash plug It is recommended to use a poker Rake the excess ash into the ash drawer Do not overfill the ash drawer Ash should accumulate higher than the 51165 of the drawer e Before removing the drawer ensure that the area around the ash opening is clean Tap the ash from the chute into the drawer then place the ash plug back over opening Only operate your appliance with a well sealed ash plug W415 1464 04 21 15 32 8 2 8 3 8 4 CREOSOTE FORMATION AND REMOVAL When wood is burned slowly it produces tar and other organic vapours which combine with expelled moisture to form creosote These vapours condense in the relatively cooler chimney flue of a slow burning fire and when ignited make an extremely hot fire So the smoke pipe chimney liner and chimney should be inspected month ly during the heating season to determine if a buildup has occurred If creosote has accumulated it should be removed to reduce the risk of a chimney fire 84 1 RUNAWAY OR CHIMNEY FIRE A CHIMNEY FIRE CAN PERMANENTLY DAMAGE YO
82. es syst mes de chauffage air puls les s che linge ou les ventila teurs de salle de bain NATIONAL FIREPLACE NOUS sugg rons que nos appareils INSTITUTE au bois soient install s et entretenus 4 par des professionnels certifi s aux Apres de longues p riodes sans utiliser l appareil telles qu la suite de vacances ou la fin de l t il se peut qu une l g re odeur se d gage pendant quelques heures Ceci est caus par Etats Unis par le National Fireplace des particules de poussi re br lant sur la chambre de combus d Institute NFI et au Canada par le tion Ouvrez une fen tre afin d a rer la piece de mani re suf Wood Energy Tech M fisante CERTIFIED wies Training WETT www nficertified org Wood Energy Si vous utilisez la prise d air ext rieur de votre appareil vous devriez jamais manquer d air comburant Si vous choisissez de ne pas utiliser cette prise d air ext rieur et que vous avez des problemes de tirage ou de fum e vous devrez ouvrir une fen tre ou trouver une autre fa on de fournir de l air comburant a l appareil AVERTISSEMENT PROPOSITION 65 DE LA CALIFORNIE L utilisation de cet appareil peut produire de la fum e qui contient des substances chimiques qui selon l tat de Californie causeraient le cancer des malformations cong nitales ou autres dangers pour la reproduction 415 1464 04 22 15 48 2 6 INFORMATION SUR LA PLAQUE D HOMOLOGATION LIST
83. est allum e cette derni re peut causer un feu de chemin e et un incendie grave pourrait s ensuivre Cet appareil a t concu pour br ler du bois naturel uniquement Ne br lez pas de d chets des r sidus de tonte de pelouse de caoutchouc des produits p troliers r siduels de la peinture ou du diluant de solvants de plastique des mat riaux contenant de l amiante des d bris de construction des traverses de chemin de fer ou de bois trait s du fumier ou des restes d animaux du bois de gr ve impr gn de sel ou des mat riaux sal s du bois non s ch de charbon de papiers de couleur de cartons des contreplaqu s ou des panneaux de particules La combustion de ces mat riaux peut entra ner la lib ration de fum es toxiques ou rendre l appareil inefficace et causer de la fum e Br lez le bois directement sur les briques r fractaires N utilisez pas un chenet et n essayez pas de sur lever le feu de quelque mani re Ne rangez pas de bois l int rieur des d gagements prescrits ou l int rieur de la zone n cessaire pour proc der au ravitaillement ou l enl vement des cendres Les cendres doivent tre mises dans un contenant m tallique avec un couvercle herm tique et d pos sur une surface incombustible suffisamment loign de la maison ou de toute structure jusqu ce qu elles soient compl tement refroidies Assurez vous de respecter les d gagements aux mat riaux combustibles lorsque vous installez un mantea
84. ez cartant les 8 22 5 broches de la goupille ILLUSTR fendue m NOTE Le mod le EP22PA S est muni de 4 tuyaux d air secondaire Les trous de l un d eux sont plus gros C est ce tuyau qui doit tre plac le plus l avant de l appareil tel qu illustr en C 415 1464 04 22 15 6 5 6 INSTALLATION DES BRIQUES DES D FLECTEURS FIBRE L UTILISATION DE L APPAREIL SANS LES D FLECTEURS PEUT CAUSER DES TEMP RATURES EXCESSIVES QUI POURRAIENT ENDOMMAGER L APPAREIL LA CHEMINEE ET L ENCEINTE Une fois l installation de l appareil et du tuyau de raccordement compl t e mettez les briques en place en proc dant tel qu illustr ci dessous EP21LA S A Installez les quatre briques A les deux briques B et les deux briques C en commen ant par la partie arri re de l appareil comme illustr NOTE Les briques arri re gauche et droite ont t coup es modele EP21LA S seulement B Installez deux briques A sur chaque c t de l appareil Installez les quatre briques A et une brique G sur la paroi arri re en les faisant pivoter sous le support briques NOTE Placez les briques troites au centre C Pivotez soigneusement les d flecteurs en fibre F et installez les sur les tuyaux d air secondaire tel qu illustr Assurez vous que les d flecteurs sont compl tement pouss s vers l arri re de la chambre de comb
85. fi ou qualifi Ne frappez pas et ne claquez pas la porte vitr e de l appareil Ne faites fonctionner l appareil qu avec les portes compl tement ferm es Seules les portes facades certifi es pour cet appareil peuvent tre utilis es avec cet appareil Gardez les mat riaux d emballage hors de la port e des enfants et mettez ces mat riaux au rebut de s curitaire Comme tous les emballages de plastique ces mat riaux ne sont pas des jouets et doivent demeurer hors de la port e des enfants et des b b s Si cet appareil n est pas install de facon ad quate un incendie pourrait s ensuivre N exposez pas l appareil aux l ments p ex la pluie etc et gardez le au sec en tout temps De l isolant humide produira une odeur lorsque l appareil est utilis La chemin e doit tre en bon tat et ne pas tre fissur e Nettoyez la chemin e au moins deux fois par ann e et lorsque n cessaire N allumez pas votre feu l aide de produits chimiques ou de liquides tels que de l essence de l huile moteur etc Votre appareil n cessite un entretien et un nettoyage p riodiques N gliger cet entretien peut causer des refoulements de fum e dans la maison Vous obtenez une meilleure efficacit et des missions plus basses avec du bois dur s ch l air qu avec du bois r sineux ou vert ou des bois durs fraichement coup s Br ler du bois vert ou humide peut causer des accumulations excessives de cr osote Lorsqu elle
86. hat the area around the ash opening be cleaned well to ensure that a proper seal is created between the new ash plug and the ash opening Once the area surrounding the opening has been cleaned place the new ash plug supplied over the opening Carefully remove the knock out from the heat shield by breaking the micro tabs e Bend out the four bend tabs at a 90 angle from the heat shield Align the slots in the ash drawer housing with the four bend tabs Secure using the four screws supplied e Secure the heat shield and ash drawer housing to the appliance using the nuts removed in step 2 e Slide the ash drawer into the ash housing W415 1464 04 21 15 6 6 3 ASH KIT EP20PAD FAILURE TO ACHIEVE GOOD SEAL BETWEEN THE ASH OPENING AND ASH PLUG WILL RESULT IN AN OVER FIRE CONDITION THAT COULD CAUSE DAMAGE TO THE APPLIANCE Provisions have been made on the appliance to install an optional ash drawer kit The kit allows for convenient removal of excess ash NOTE It is recommended to install the rails on the pedestal base prior to installing the pedestal assembly to the firebox e the appliance has been previously operated it must be cold and the ashes must be removed in order to access the ash plug e If the pedestal has been installed with the opening to the back it will be necessary to lay the appliance onto its back remove the pedestal and re install it with the opening to the front It is rec
87. he connector should never exceed 8 2 4m to 10 3 1m In the case of vertical installation the total length of the connector can be longer and connected without problem to the chimney at the ceiling level e There should never be more than two 90 elbows in the entire connector and chimney system Never start with a 90 elbow Always go up vertically for at least 2 feet 0 6m from the flue collar before using a 90 elbow e The connector must not pass through any combustible material nor may it pass through a concealed space such as an attic roof space or closet If passing through a wall ceiling or into a masonry chimney use either chimney components listed for that specific use or means acceptable to local authorities having jurisdiction over the installation This appliance must be connected to A A chimney complying with the requirements for Type HT chimneys in the Standard for Chimneys Factory Built Residential Type and Building Heating Appliance or MALE END OF B A code approved masonry chimney with a flue CONNECTOR liner Vent the stove into a masonry chimney or an approved insulated solid fuel stainless steel chimney with as short and straight a length of 6 152 4mm diameter chimney connector as possible Connection FLUE GAS to a masonry chimney must be by a metal or masonry DIRECTION thimble cemented in place 58 1B W415 1464 04 21 15
88. iodic maintenance and cleaning Failure to maintain your appliance may lead to smoke spillage in your home e Lower emissions generally result when burning air dried seasoned hardwoods as compared to softwoods or too green or freshly cut hardwoods Burning wet unseasoned wood can cause excessive creosote accumulation When this is ignited it can cause a chimney fire that may result in a serious house fire e This appliance is designed to burn natural wood only Do not burn trash or garbage lawn clippings waste rubber waste petroleum products paints or paint thinners solvents plastic materials containing asbestos construction debris railroad ties or treated wood manure or animal remains salt water driftwood or salted materials unseasoned wood coal charcoal coloured paper cardboard plywood or particleboard Burning these materials may result in release of toxic fumes or render the appliance ineffective and cause smoke e Burn wood directly on the firebricks Do not elevate grate or otherwise raise the fire e not store wood within appliance installation clearances or within the space required for re fueling and ash removal e Ashes must be disposed in a metal container with a tight lid and placed on a non combustible surface well away from the home or structure until completely cool e Ensure clearances to combustibles are maintained when building a mantel or shelves above the appliance Elevated temperatures on the wall or i
89. isamment l appareil l utilisation PEUT CAUSER DES BR LURES de bois vert ou humide le contr le de combustion est trop ferm cr ant une ES NP i LAISSER REFROIDIR LA SURFACE insuffisance d air pour r aliser une combustion compl te S il est n cessaire de VITREE AVANT D Y TOUCHER nettoyer la vitre utilisez un linge doux avec un nettoyeur sans abrasif NE PERMETTEZ JAMAIS A UN ENFANT DE TOUCHER LA SURFACE NE PAS NETTOYER LORSQU ELLE EST CHAUDE Nettoyez la vitre avec un VITREE nettoyeur recommand apr s les dix premi res heures de fonctionnement Par la Suite nettoyez aussi souvent qu il le faudra La vitre est tr s r sistante mais ne laissez pas de bois en combustion s appuyer contre elle Fermez toujours la porte doucement NE FORCEZ JAMAIS POUR LA FERMER Si la vitre devait fissurer pendant que le feu br le n ouvrez pas la porte jusqu ce que le feu s teigne et n utilisez pas l appareil jusqu ce que la vitre ait t remplac e par une nouvelle disponible chez votre d taillant autoris N UTILISEZ PAS DE MATERIAUX SUBSTITUTS 5 3 415 1464 04 22 15 8 8 19 BOIS CET APPAREIL A ETE CONCU POUR BRULER DU BOIS NATUREL UNIQUEMENT NE BRULEZ PAS DE BOIS TRAITES DE CHARBON DE BOIS DE CHARBON DE PAPIERS DE COULEUR DE CARTONS DE SOLVANTS NI DE DECHETS CET APPAREIL N A PAS ETE TESTE AVEC UN ENSEMBLE DE BUCHES A GAZ NON VENTILEES AFIN DE REDUIRE LE RISQUE D INCENDIE OU DE BLESSURE
90. ith the door tightly closed BURNS Burn wood behind the log retainer directly on the firebricks Do not use an elevated grate or otherwise raise the fire DO NOT TOUCH GLASS UNTIL At least 14 square inches 90 square centimeters of outside air must be admitted to the room or directly to the unit through a 4 102mm diameter COOLED pipe This appliance is designed to burn natural wood only Higher efficiencies NEVER ALLOW CHILDREN TO and lower emissions generally result when burning air dried seasoned TOUCH GLASS hardwoods as compared to softwoods or to green or freshly cut T HPBA hardwoods Hearth Patio amp Barbecue Association Quality System Certified To Tested amp Listed By Portland Oregon USA Do not start a fire with chemicals or fluids such as gasoline engine oil etc Do not burn trash or garbage lawn clippings waste rubber waste petroleum products paints or paint thinners solvents plastic materials containing asbestos construction debris railroad ties or treated wood manure or animal remains salt water driftwood or salted materials unseasoned wood coal charcoal coloured paper cardboard plywood or US 9 1 2 Test Laboratories Inc particleboard Do not let the appliance become hot enough for any part to glow red KEEP THE STOVE TEMPERATURE BELOW 700 371 C Attempts to achieve heat output rates that exceed
91. la soufflerie et son boitier tel qu illustr en utilisant les quatre vis fournies D Desserrez le support de l interrupteur thermique deux vis et faites glisser le support vers l avant jusqu ce que l interrupteur thermique touche l arri re de la chambre de combustion et fixez gt lt SUPPORT DE L INTERRUPTEUR MOD LE SUR PIEDESTAL THERMIQUE EP21LA S ILLUSTRE W415 1464 04 22 15 65 6 2 ENSEMBLE TIROIR CENDRES EP20LAD SI LE JOINT ENTRE L OUVERTURE DE LA CHUTE CENDRES ET LE COUVERCLE N EST PAS TANCHE CELA ENTRA NERA UNE SURCHAUFFE POUVANT CAUSER DES DOMMAGES A L APPAREIL Cet appareil a t concu pour recevoir un tiroir cendres optionnel Cet ensemble vous permettra de disposer ais ment des cendres e Si l appareil a d j t utilis il doit tre refroidi et vous devez enlever les cendres pour acc der au couvercle de la chute cendres NOTE Pour recueillir les cendres qui pourraient tomber durant l installation placez le tiroir cendres sous l appareil e partir du dessous de l appareil retirez les crous qui retien nent l cran thermique et la plaque de recouvrement e Retirez la petite brique qui couvre l ouverture de la chute cendres et jetez la est important de bien nettoyer la r gion de l ouverture de la chute cendres afin d assurer une tanch it ad quate entre le nouveau couvercle et l ouverture e Une fois que la r gion est
92. ll provide replacement parts free of charge during the first year of the limited warranty Any labour related to warranty repair is not covered Construction of models vary Warranty applies only to components included with your specific appliance CONDITIONS AND LIMITATIONS Wolf Steel warrants its TIMBERWOLF products against manufacturing defects to the original purchaser only Registering your warranty is not necessary Simply provide your proof of purchase along with the model and serial number to make a warranty claim Provided that the purchase was made through an authorized TIMBERWOLF dealer your appliance is subject to the following conditions and limitations Warranty coverage begins on the date of original installation This factory warranty is non transferable and may not be extended whatsoever by any of our representatives The appliance must be installed by an authorized service technician or contractor Installation must be done in accordance with the installation instructions included with the product and all local and national building and fire codes This limited warranty does not cover damages caused by misuse lack of maintenance accident alterations abuse or neglect Operating the appliance on high for extended periods of time is neglect Parts installed from other manufacturers will nullify this warranty This limited warranty further does not cover any scratches dents corrosion or discoloring caused by excessive heat
93. long e ou tendue par aucun de nos repr sentants quelle qu en soit la raison L appareil doit tre install par un installateur ou un entrepreneur qualifi L installation doit tre faite conform ment aux instructions d installation incluses avec le produit et tous les codes d incendie et de construction locaux et nationaux Cette garantie limit e ne couvre pas les dommages caus s par un mauvais usage un manque d entretien un accident des alt rations des abus ou de la n gligence Faire fonctionner l appareil au r glage maximal pendant des p riodes prolong es constitue de la n gligence L installation de pi ces d autres fabricants annulera cette garantie Cette garantie limit e ne couvre pas non plus les gratignures le bossellement la corrosion ou la d coloration caus e par une chaleur excessive des produits d entretien chimiques et abrasifs ou l caillage des pi ces en porcelaine maill e le bris de tout composant de ventilation utilis dans l installation de l appareil Au cours de la premi re ann e seulement cette garantie s tend la r paration ou au remplacement des pi ces garanties dont les mat riaux ou la fabrication sont d fectueux sous condition que le produit ait t utilis conform ment aux instructions de fonctionnement et dans des conditions normales Apr s la premi re ann e concernant cette Garantie Vie Limit e TIMBERWOLF Wolf Steel peut sa discr tion se lib rer enti rement de to
94. m the date of their installation The manufacturer may require that defective parts or products be returned or that digital pictures be provided to support the claim Returned products are to be shipped prepaid to the manufacturer for investigation If a product is found to be defective the manufacturer will repair or replace such defect Before shipping your appliance or defective components your dealer must obtain an authorization number Any merchandise shipped without authorization will be refused and returned to sender Shipping costs are not covered under this warranty Additional service fees may apply if you are seeking warranty service from a dealer Labour travel diagnostic tests shipping and other related charges are not covered by this warranty ALL SPECIFICATIONS AND DESIGNS ARE SUBJECT TO CHANGE WITHOUT PRIOR NOTICE DUE TO ON GOING PRODUCT IMPROVEMENTS 2 11B W415 1464 04 21 15 NAPOLEON 24 Napoleon Road Barrie Ontario Canada L4M 068 214 Bayview Drive Barrie Ontario Canada LAN 4Y8 103 Miller Drive Crittenden Kentucky USA 41030 7200 Trans Canada Highway Montreal Quebec Canada H4T 1A3 Fireplaces Heating amp Cooling call 705 721 1212 Grills call 705 726 4278 napoleonproducts com Fireplace Inserts Charcoal Grills Gas Fireplaces e Waterfalls e Wood Stoves Heating amp Cooling e Electric Fireplaces e Outdoor Fireplaces e Gas Grills INSTALLATEUR LAISSEZ CE MANUEL AVEC L APPARE
95. n the air above the appliance can cause melting discolouration or damage to decorations a T V or other electronic components 3 17E 415 1464 04 21 15 2 1 DIMENSIONS EP21LA S 26 660 4mm 13 330 2mm O D 6 19 3 4 We 501 7mm T m 6 1 2 31 1 2 800 1mm 21 5 8 549 3mm SYS EP22PA S 13 330 2mm NH 24 5 8 s 16 1 2 6 o Amm 165 1 625 5mm LE 2 2 SPECIFICATIONS Specifications EP21LA S 28 5 0 267 660 4 21 5 8 549 3mm 24 5 8 549 3mm 6 1 2 165 1mm 13 330 2mm 13 330 2mm 29 7 8 758 8mm 29 7 8 758 8mm 31 1 2 800 1mm 31 3 8 800 1mm 11 5 8 x 20 7 8 x 11 5 8 14 5 8 x 20 7 8 x 11 5 8 295 3mm x 530 2mm x 295 3mm 371 5mm x 530 2mm x 295 3mm CAPACITY 1 5 cubic feet 0 04 cubic meters 1 9 cubic feet 0 05 cubic meters 22 3 4 577 9mm 31 3 8 769 9mm WEIGHT w o BRICKS 180 lbs 81 6 kg 210 1 5 95 kg WEIGHT OF BRICKS 47 lbs 21 3 kg 60 Ibs 27 kg IDEAL WOOD LENGTH 16 406 4mm 16 406 4mm tested using the test method 28 Figures will vary considerably with individual conditions Wolf Steel Ltd estimated realistic BTU hr with hardwood logs and regular refueling W415 1464 04 21 15 6 2 3 GENERAL INSTRUCTIONS ALL WIRING SHOULD
96. n trop grand nombre de coudes S agit il d un tirage faible caus par une chemin e non herm tique une chemin e ext rieure froide un diam tre de chemin e trop grand une chemin e trop courte ou trop pr s des arbres ou d un toit plus lev 8341 415 1464 04 22 15 71 8 0 ENTRETIEN COUPEZ L ALIMENTATION LECTRIQUE AVANT DE PROC DER L ENTRETIEN DE L APPAREIL L APPAREIL PEUT TRE CHAUD N EFFECTUEZ AUCUN ENTRETIEN JUSQU CE QUE L APPAREIL SOIT REFROIDI N UTILISEZ PAS DE NETTOYANTS ABRASIFS Afin de pr venir les accumulations de suie et de cr osote v rifiez votre chemin e et le conduit de raccorde ment toutes les semaines jusqu ce qu une fr quence de nettoyage s curitaire soit tablie Si les accumulations sont excessives d branchez l appareil et nettoyez le ainsi que la chemin e Vous pour riez faire appel aux services d un ramoneur professionnel pour nettoyer l appareil et la chemin e ils doivent tre nettoy s au moins une fois l an ou aussi souvent que n cessaire Enlevez les d flecteurs en fibre et nettoyez au dessus une fois par ann e Remplacez les briques bris es 8 1 ENLEVEMENT DES CENDRES AVEC TIROIR CENDRES L LIMINATION INCORRECTE DES CENDRES CAUSE DES INCENDIES NE JETEZ PAS LES CENDRES DANS DES BOITES EN CARTON NE LES JETEZ PAS DANS LA COUR ET NE LES ENTREPOSEZ PAS DANS UN GARAGE SI VOUS UTILISEZ UN ASPIRATEUR POUR NETTOY
97. ne barri re de s curit pour garder les jeunes enfants et autres individus risque hors de la pi ce et loign s des surfaces chaudes Les v tements et autres mat riaux combustibles ne doivent pas tre pos s sur le foyer ou proximit En raison des temp ratures lev es le foyer devrait tre plac loin des endroits passants et loin des meubles et des rideaux Les objets plac s devant l appareil doivent tre gard s une distance d au moins 48 1219 2mm de l avant de l appareil Assurez vous de disposer de mesures de s curit ad quates pour emp cher les jeunes enfants de toucher aux surfaces chaudes M me une fois que le foyer est teint la vitre et ou le pare tincelles demeureront chauds pendant un temps prolong Consultez votre d taillant local de foyer pour connaitre les grillages de s curit et les crans offerts pour prot ger les enfants des surfaces chaudes Ces grillages de s curit et ces crans doivent tre fix s au plancher Les grillages de s curit ou crans enlev s pour faire l entretien devront tre remis en place avant d utiliser l appareil Cet appareil ne devra tre modifi en aucun cas Cet appareil ne doit pas tre raccord au conduit d une chemin e desservant un autre appareil de chauffage combustible solide Ne pas op rer l appareil lorsque la porte vitr e est enlev e fissur e ou bris e Le remplacement de la vitre devra tre effectu par un technicien de service certi
98. nt contenues dans ce manuel W385 2042 415 1464 04 21 15 3 0 PRE INSTALLATION PREPARATION 3 1 3 2 3 3 APPLIANCE PLACEMENT Have an authorized dealer install the appliance If you install the appliance yourself have your dealer review your installation plans and or installation Draw out a detailed plan of the installation including dimensions and verify the dimensions with the require ments listed in this manual You may wish to adjust the appliance position slightly to ensure the vent does not intersect with a framing member Appliance must be positioned so that no combustibles are within or can swing within e g drapes doors 48 1219 2mm of the front of the appliance 67 1B MINIMUM CLEARANCE TO COMBUSTIBLES DO NOT INSTALL INTO ANY AREA HAVING LESS THAN 7 FEET CEILING TO APPLIANCE BOTTOM EXCLUDING HEARTH HEIGHT BACK WALL BACK WALL D C gt SIDE WALL SIDE WALL PARALLEL amp CORNER SINGLE WALL CONNECTOR DOUBLE WALL CONNECTOR 19 482 6mm 19 482 6mm 28 7 8 733 4mm 28 7 8 733 4mm 21 533 4mm 16 406 4mm 7279 75 1905mm Clearances be reduced with shielding acceptable to local authorities Reduced installation must comply with NFPA 211 or CAN CSA B365 ALCOVE INSTALLATION Your appliance may be installed using a listed double wall connector such as Security DL6 in Canada the Simpson Duravent Plus DVL in the USA or an equivalent d
99. nt subi un nombre consid rable de tests 7 dans des laboratoires canadiens am ricains Ce syst me est le plus 4 efficace le plus simple et sans probl me connu il fonctionne comme suit fe L air secondaire p n tre par l ouverture arri re monte par l arri re le long B N du tuyau d air secondaire jusqu au collecteur install au sommet ou l air Y est propuls lat ralement pour oxyder les gaz sous la sortie de fum e EN _ La chambre de combustion inf rieure est rev tue de briques r fractaires 4 haute temp rature sur deux c t s l arri re et le plancher Le plafond est rev tu de d flecteurs en fibre afin de maintenir une temp rature E 2 5 lev e dans la chambre de combustion Ainsi les gaz qui se m langent EP21 ILLUSTR l air pr r chauff dans le tuyau d air secondaire s allument et br lent facilement Les c t s et l arri re de l appareil sont munis d une deuxi me paroi de fa on diriger la chaleur vers le haut et vers l avant dans la pi ce Assurez vous qu il y ait suffisamment d air comburant Dans la maison beaucoup d appareils doivent se partager l air disponible tels le s hottes de cuisini re l
100. ommended all fire brick including baffles be removed prior to placing the appliance on its back e From the underside of the appliance remove the nuts that secure the ash ASH OPENING COVER PLATE opening cover plate e Install the ash pan rails using the screws provided 1 e Snap the magnets into place e Slide the ash drawer into the ash housing e Install the handle using the screws provided and affix the logo to the ash pan housing cover as illustrated e Place the ash pan housing cover in front of the opening engaging it into the slots e Remove the small light weight brick that was covering the ash opening and discard It is important that the area around the ash opening be cleaned well to ensure that a proper seal is created between the new ash plug and the ash opening Once the area surrounding the opening has been cleaned place the new ash plug supplied over the opening allowing the protrusion on the brick to recess into the opening on the bottom of the firebox LOGO 22 PLACEMENT 415 1464 04 21 15 27 7 0 OPERATION ALWAYS OPERATE THIS APPLIANCE WITH THE DOOR CLOSED AND LATCHED DURING START UP AND RE FUELING ALWAYS WEAR GLOVES TO PREVENT INJURY DO NOT LEAVE THE FIRE UNATTENDED WHEN THE DOOR IS UNLATCHED AS UNSTABLE WOOD COULD FALL OUT OF THE FIRE CHAMBER CREATING A FIRE HAZARD TO YOUR HOME NEVER L
101. orent en ouvrant une fen tre lors d une journ e sans vent Un syst me de ventilation est install dans la maison D autres appareils vacuent l air de la maison Les fen tres de la maison sont tanches ou la maison est bien scell e Les syst mes HRV sont con us pour amener l air frais dans votre maison et r soudront les probl mes de performance li s votre appareil 415 1464 04 22 15 51 4 0 INSTALLATION PORTEZ DES GANTS ET DES LUNETTES DE PROTECTION SUIVEZ ATTENTIVEMENT LES INSTRUCTIONS POUR L ASSEMBLAGE DE LA CHEMIN E ET DES AUTRES COMPOSANTS N CESSAIRES L INSTALLATION DE L APPAREIL TOUTE OMISSION POURRAIT CAUSER UN INCENDIE PARTICULI REMENT SI DES MATERIAUX COMBUSTIBLES SONT TROP PRES DE L APPAREIL OU DE LA CHEMIN E ET QUE DES OUVERTURES D AIR SONT BLOQU ES EMP CHANT LA LIBRE CIRCULATION DE L AIR DE REFROIDISSEMENT N INSTALLEZ PAS LA PRISE D AIR EXT RIEUR DANS LE GARAGE LES PRODUITS D CHAPPEMENT PROVENANT DES MOTEURS ESSENCE SONT DANGEREUX N INSTALLEZ PAS LA PRISE D AIR EXT RIEUR DANS UN GRENIER UN SOUS SOL O AU DESSUS DU TOIT O D AUTRES APPAREILS DE CHAUFFAGE DES VENTILATEURS ET DES CHEMIN ES EVACUENT OU TIRENT DE L AIR CES MESURES R DUIRONT LES POSSIBILIT S DE REFOULEMENT DE FUM E UNE INVERSION DU D BIT D AIR L ENTR E DE LA PRISE D AIR DOIT DEMEURER D GAG E DE FEUILLES DE D BRIS DE GLACE DE NEIGE ELLE DOIT TRE D GAG E LORSQUE L APPAREIL FONCTIONNE AFIN QU
102. ot for an extended period of time e Check with your local hearth specialty dealer for safety screens and hearth guards to protect children from hot surfaces These screens and guards must be fastened to the floor e safety screen or guard removed for servicing must be replaced prior to operating the appliance e Under no circumstances should this appliance be modified e This appliance must not be connected to a chimney flue pipe servicing a separate solid fuel burning appliance e Do not operate the appliance with the glass door removed cracked or broken Replacement of the glass should be done by a licensed or qualified service person e Do not strike or slam shut the appliance glass door e Only doors optional fronts certified with the unit are to be installed on the appliance e Keep the packaging material out of reach of children and dispose of the material in a safe manner As with all plastic bags these are not toys and should be kept away from children and infants e If the appliance is not properly installed a house fire may result Do not expose the appliance to the elements ex rain etc and keep the appliance dry at all times Wet insulation will produce an odour when the appliance is used e chimney must be sound and free of cracks Clean your chimney a minimum of twice a year and as required e not start a fire with chemicals or fluids such as gasoline engine oil etc e Your appliance requires per
103. ouble wall connector into F an alcove having a depth of no more than 24 28 609 6 mm and a height of at least 6 3 1905 ALCOVE 733 4mm mm The minimum clearances are as shown 24 609 6mm MAX ALCOVE PARALLEL amp CORNER SINGLE WALL CONNECTOR DOUBLE WALL CONNECTOR CEILING F 75 1905mm NOTE Minimum width 64 1625 6mm Minimum depth 32 812 8mm W415 1464 04 21 15 10 3 4 FLOOR PROTECTION EMBER PROTECTOR This appliance must be installed on a non combustible protector that extends to the front sides back of the appliance as per the minimum requirements below NOTE Ember protection is required for spark and ash shielding not for limiting floor temperatures from the radiant heat of the appliance The appliance was designed and safety tested so that without any protection the floor will not overheat Y LE FRONT I SIDES J BACK K VENT L CANADA 18 457 2mm 8 203 2mm 8 203 2mm Ll 16 406 4mm 8 203 2mm 8 203 2 2 50 8mm NOTE If a section of horizontal chimney connector is used floor protection is required under the chimney connector and 2 50 8mm beyond each side 3 5 OUTSIDE AIR The following are signs that fresh air may be required e When there is combustion present Wood burns poorly smoke spills back draft takes place and your chimney does not draw steadily In the winter there is too
104. oyers ext rieurs e Grils gaz de qualit
105. plac ou puisse pivoter p ex rideaux portes moins de 48 1219 2mm de la face vitr e du po le D GAGEMENTS AUX MAT RIAUX COMBUSTIBLES 67 1B NE L INSTALLEZ PAS DANS UN ESPACE AYANT MOINS DE 7 PIEDS DE HAUTEUR DU PLAFOND AU BAS DE L APPAREIL EXCLUANT LA HAUTEUR DE LA BASE DE PROTECTION MUR ARRIERE MUR ARRIERE PARALLELE EN COIN CONDUIT DE RACCORDEMENT CONDUIT DE RACCORDEMENT A PAROI SIMPLE A PAROI DOUBLE 19 482 6 mm 19 482 6 mm 28 7 8 733 4 mm 28 7 8 733 4 mm 17 1 2 444 5 mm 12 1 2 317 5 mm 167 406 4 mm 75 1905 est possible de r duire les d gagements l aide d un protecteur conforme aux normes des autorit s lo cales installation r duite doit tre conforme aux normes 211 ou au CAN CSA 8365 INSTALLATION DANS UNE ALC VE Votre appareil doit tre install l aide d un conduit de raccordement double paroi certi tel que Security DL6 au Canada Simpson Duravent Plus DVL aux tats Unis ou un conduit F de raccordement a double paroi equivalent dans ALCOVE une alc ve d une profondeur ne d passant pas 24 609 6 et d une hauteur d au moins 6 3 1950 mm Les d gagements minimaux sont tels qu illustr D A MUR DE C T MUR DE C T 24 609 6mm MAX PARALL LE COIN CONDUIT DE RACCORDEMENT CONDUIT DE RACCORDE PAROI SIMPLE MENT A PAROI DOUBLE yy NO
106. pour valider la r clamation Les produits retourn s doivent tre exp di s port pay au fabricant pour une inspection en usine Si un produit est d clar d fectueux le fabricant le r parera ou le remplacera Avant d exp dier votre appareil ou les pi ces d fectueuses votre d taillant doit obtenir un num ro d autorisation Toute marchandise exp di e notre usine sans autorisation sera refus e et retourn e l exp diteur Les co ts d exp dition ne sont pas couverts par cette garantie Des frais de service suppl mentaires peuvent tre appliqu s si vous cherchez obtenir des services au titre de la garantie aupr s d un d taillant Les frais de d placement pour main d oeuvre de tests de diagnostic d exp dition et autres frais aff rents ne sont pas couverts par cette garantie TOUTES LES SP CIFICATIONS ET LES CONCEPTIONS SONT SUJETTES MODIFICATIONS SANS PR AVIS EN RAISON DES AM LIORATIONS CONSTANTES APPORT ES AU PRODUIT 2 11B 415 1464 04 22 15 7200 Route Transcanadienne Montr al Qu bec HAT 1 24 Napoleon Road Barrie Ontario Canada L4M 068 214 Bayview Drive Barrie Ontario Canada LAN 4Y8 103 Miller Drive Crittenden Kentucky USA 41030 Foyers Chauffage et Climatisation Grils composez 514 737 6294 napoleonproducts com Foyers encastr s e Grils au charbon de bois Foyers au gaz e Cascades d eau Po les bois e Produits HVAC e Foyers lectriques e F
107. r pieces of wood compactly packed close enough to prevent the flames from penetrating it completely After approximately 30 minutes depending on the size of the load close the draft control completely making sure that the fire is not extinguished DO NOT OVERFIRE THE APPLIANCE Overfiring can occur by A Burning large amounts of smaller wood pieces such as furniture scraps skids or treated wood B Vigorously burning large loads of wood with the draft control on HIGH fully open for long periods of time one or two hours C Operating the appliance with the ash dump door blocked open or a poor gasket seal on the main door 82 1 7 6 SMOKING A properly installed appliance should not smoke If yours does check the following e Has the chimney had time to get hot e Is the smoke passage blocked anywhere in the appliance chimney connector or chimney e Is the room too airtight and the air intake not connected to the outside Try with a window partly open Is the smoke flow impeded by too long a horizontal pipe or too many bends e Is it a weak draft perhaps caused by a leaky chimney a cold outside chimney too large a diameter of a chimney too short a chimney or a chimney too close to trees or a higher roof Is the moisture content of the wood greater than 2096 83 1A 415 1464 04 21 15 31 8 0 MAINTENANCE TURN OFF THE POWER BEFORE SERVICING THE APPLIANCE APPLIANCE MAY BE HOT DO NOT SERVICE UNTI
108. re extinguisher in a central location known to all at least one smoke detector and carbon monoxide CO detector in the room containing the appliance If the smoke detector sounds an alarm correct the cause but do not de activate or relocate the smoke detector If the carbon monoxide detector sounds an alarm immediately vent the area evacuate and call your local fire department 91 1A 7 3 FUEL DO NOT STORE FUEL WITHIN THE CLEARANCE TO COMBUSTIBLES OR IN THE SPACE REQUIRED FOR RE FUELING AND ASH REMOVAL BURNING WET UNSEASONED WOOD CAN CAUSE EXCESSIVE CREOSOTE ACCUMULATION WHEN IGNITED IT CAN CAUSE A CHIMNEY FIRE THAT MAY RESULT IN A SERIOUS HOUSE FIRE When loading the appliance ensure that the two upper fibre baffles are not lifted up and off their ledge For maximum efficiency when the appliance is thoroughly hot load it fully to the top of the door opening and burn at a medium low setting Maximum heat for minimum fuel optimum burn occurs when the appliance top temperature is between 500 F 260 C and 600 F 315 The bricks will be nearly all white and the glass mostly clear The whiteness of the bricks and the cleanliness of the glass are good indicators of your operating efficiency Not enough heat is produced when only one or two pieces of wood are burned or the wood may not burn completely A minimum of three pieces are needed to encase a bed of coals that sustains the fire NOTE When loading the appliance ensure to ke
109. rez vous de garder le combustible loign de la vitre Si des braises s accumulent sur le rebord avant elles pourraient tomber hors de l appareil quand vous ouvrez la porte Ne br lez que du bois propre non peint et bien sec produit plus de chaleur et moins de suie et de cr osote Le bois fraichement coup contient environ 50 96 d humidit tandis qu une fois s ch il n en contient que 20 96 CIRCULATION Quand le bois br le l eau bout en consommant une partie de l nergie qui aurait d D AIR produire de la chaleur Plus le bois est humide moins il y m aura de chaleur et plus il y aura de cr osote Le bois sec a des craquelures dans les extr mit s Le bois dur br le aussi bien que le bois r sineux dans cet appareil par contre le bois dur est plus dense plus ge 77 lourd br le plus lentement et plus longtemps j Le bois de chauffage devra tre fendu et cord de telle facon que l air puisse circuler ais ment au travers Il faudra couvrir la corde de bois au d but du printemps pour qu elle soit pr te tre br l e l automne suivant Coupez le bois de fa on ce qu il puisse rentrer CIRCULATION D AIR horizontalement de l arri re vers l avant dans l appareil Ceci facilite le chargement et il y aura moins de risque que le bois roule sur la vitre CIRCULATION D AIR Les b ches artificielles obtenues par la compression de fibre de bois 100 naturelle peuvent tre utilis es sans danger comme com
110. s and one G brick along the back wall by pivoting the bricks up under the brick retainer NOTE Place narrow brick in centre C Carefully pivot fibre baffles F up onto the secondary air tubes as illustrated in Fig 1 Ensure that the top baffles are pushed all the way to the rear of the firebox leaving a minimum of a 1 inch gap along the front This will allow the flue gases to escape the firebox Ensure overlap joint illustrated on the next page is tight D Install the two D bricks along the front EP22PA S A Install the nine A bricks and one B brick working from the back of the appliance forward as illustrated B Install four A bricks along both sides of the appliance Install the four A bricks and one E brick along the back wall by pivoting the bricks up under the brick retainer NOTE Place narrow brick in centre C Carefully pivot fibre baffles F up onto the secondary air tubes as illustrated in Fig 1 Ensure that the top baffles are pushed all the way to the rear of the firebox leaving a minimum of a 1 inch gap along the front This will allow the flue gases to escape the firebox Ensure overlap joint illustrated on the next page is tight D Install the two D bricks along the front EP21LA S EP22PA S W415 1464 04 21 15 3 7 OVERLAP JOINT BAFFLE QE ae SECONDARY S 9 AIR TUBES NE
111. s sur le plancher de l appareil et couvrez les de bois d allumage Ouvrez compl tement le contr le de combustion en le d pla ant compl tement droite Allumez le papier et laissez la porte l g rement entrouverte un pouce jusqu ce que tout le bois d allumage soit enflamm Pour maintenir un feu vif un lit de braises doit se former et tre entretenu Lentement ajoutez des morceaux de bois plus gros 2 x 4 Posez les morceaux dans le lit de braises parall lement l arri re de l appareil tout en gardant une tranch e peu profonde entre les morceaux de bois Ainsi l air comburant primaire circulera directement dans la tranch e et allumera le bois Lorsque la flamb e semble son maximum des b ches de dimensions moyennes peuvent tre ajout es Une fois que ces morceaux ont pris feu fermez la porte doucement Le fait de fermer la porte imm diatement apr s le chargement entrainera une diminution de temp rature dans la chambre de combustion et se traduira par une combustion insatisfaisante Rappelez vous qu il est plus efficace de br ler des morceaux de bois de dimensions moyennes feu vif et de recharger plus souvent que d alimenter l appareil avec des gros morceaux qui produiront un feu languissant et inefficace qui salira la vitre 415 1464 04 22 15 66 Une fois que la porte est ferm e vous observerez un changement dans le comportement des flammes Elles devien dront plus petites et plus paresseuses parce
112. s the door is closed you will observe a change in the flame pattern The flames will get smaller and lazier because less oxygen is getting into the combustion chamber The flames however are more efficient The flames will remain lazy but become larger again as soon as the firebricks have been heated thoroughly and the chimney becomes heated and provides a good draft At this point the roaring fire that you see when the door is opened 15 wastefully drawing heated room air up the chimney certainly not desirable Always operate with the door fully closed once the medium sized logs have caught fire You can now add larger pieces of wood and operate the appliance normally Once the appliance is entirely hot it will burn very efficiently with little smoke from the chimney There will be a bed of orange coals in the firebox and secondary flames flickering just below the top baffles You can safely fill the firebox with wood to the top of the door and will get best burns if you keep the appliance pipe temperatures between 250 degrees Fahrenheit 120 degrees Celsius and 450 degrees Fahrenheit 270 degrees Celsius A surface thermometer will help regulate this W415 1464 04 21 15 28 7 2 7 1 Without appliance thermometer you working blindly and have idea of how the is operating An appliance thermometer offers a guide to performance and should be located 18 457mm above the flue collar Install the thermometer
113. shes may result Normally a hot fire will clean the glass The most common reasons for dirty glass include not using W HOT GLASS WILL sufficient fuel to get the appliance thoroughly hot using green CAUSE BURNS or wet wood closing the draft so far that there is insufficient air DO NOT TOUCH GLASS for complete combustion UNTIL COOLED If it is necessary to clean the glass buff lightly with a clean dry NEVER ALLOW CHILDREN cloth and non abrasive cleaner TO TOUCH GLASS DO NOT CLEAN GLASS WHEN HOT Clean the glass after the first 10 hours of operation with a recommended appliance glass cleaner Thereafter clean as required The glass is very strong but do not let burning fuel rest or fall against it and always close the door gently NEVER FORCE IT SHUT If the glass should ever crack or break while the fire is burning do not open the door until the fire is out and do not operate the appliance again until the glass has been replaced available from your Authorized dealer DO NOT SUBSTITUTE MATERIALS 5 3 W415 1464 04 21 15 39 8 8 WOOD THIS APPLIANCE IS DESIGNED TO BURN NATURAL WOOD ONLY DO NOT BURN TREATED WOOD COAL CHARCOAL COLOURED PAPER CARDBOARD SOLVENTS OR GARBAGE THIS APPLIANCE HAS NOT BEEN TESTED WITH AN UNVENTED GAS LOG SET TO REDUCE RISK OF FIRE OR INJURY DO NOT INSTALL AN UNVENTED GAS LOG SET INTO THE APPLIANCE HIGHER EFFICIENCIES AND LOWER EMISSIONS GENERALLY RESULT WHEN BURNING AIR DRIED SEASON
114. should always be followed in accordance with local and national codes In Canada the CSA B365 and the CSA C22 1 installation codes are to be followed In the USA the ANSI NFPA 70 and ANSI NFPA 211 installation codes are to be followed Chimney and chimney connector must be in good condition and kept clean 415 1464 04 21 15 133 4 1 1 CONNECTION Your chimney connector chimney must have the same diameter as the 5 exhaust flue outlet The appliance pipe must be made of aluminized or cold roll steel with a minimum 24 gauge 0 6mm thickness It is strictly forbidden to use galvanized steel A 6 152 4mm diameter single wall chimney connector used to connect the appliance to the chimney must be installed with the crimped end toward the appliance This will ensure that the moisture which condenses from the burning wood will flow back into the fire chamber Each joint in the chimney connector must be secured with at least three sheet metal screws For installation of your chimney connector the following recommendations may be useful e The chimney connector must be short and straight For optimum performance it is recommended that all horizontal runs have a minimum 1 4 6 35mm rise per 1FT 0 3m with the upper end of the section toward the chimney For safe and proper operation of the appliance see INSTALLATION instructions e To insure a good draft the total horizontal length of t
115. t le r installer avec l ouverture situ e l avant Nous vous conseillons de retirer toutes les briques r fractaires ainsi que les d flecteurs avant de coucher l appareil sur le dos e A partir du dessous de l appareil retirez les crous qui retiennent la plaque de recouvrement PLAQUE DE Installez les rails du tiroir cendres l aide des vis fournies Installez les deux loquets aimant s Ins rez le tiroir cendres dans le compartiment cendres Installez la poign e l aide des vis fournies et apposez le logo sur la porte d acc s comme illustr e Placez la porte d acc s devant l ouverture en l ins rant dans les fentes e Retirez la petite brique qui couvre l ouverture de la chute cendres et jetez la est important de bien nettoyer la r gion de l ouverture de la chute cendres afin d assurer une tanch it ad quate entre le nouveau couvercle et l ouverture e Une fois que la r gion est bien nettoy e mettez le nouveau couvercle de la chute cendres fourni sur ouverture en vous assurant que la protuberance sous la brique est ench ss e dans l ouverture du plancher de la chambre de combustion
116. t should be used in heating The wetter the wood the less heat is given off and the more creosote is produced Dry firewood has cracks in the end of the grain Both hardwood and softwood burn equally well in this Wl a 7 appliance but hardwood is denser will weigh more AIR FLOW per cord and burn a little slower and longer AIR FLOW Firewood should be split stacked in a manner that air can Bel to all parts of it and covered in early spring to be ready for burning that fall Dry firewood has cracks in the end grain Cut the wood so that it will fit horizontally front to back making for easier loading and less of a likelihood that the wood will roll onto the glass Manufactured firelogs made by compressing 10096 natural wood fibre can be safely used as fuel Do not use manufactured firelogs if they contain additives such as paraffin wax binders etc Never burn more than two manufactured firelogs at a time DO S DONT S Build a hot fire Take ash out immediately Let it accumulate to a Use only dry wood with 20 moisture content depth of at least one inch A good ash layer provides Several pieces of medium sized wood are better for a longer lasting and better burning fire than a few big pieces Burn wet wood with more than 20 moisture content e Clean chimney regularly Close the door too soon or damper down too quickly Refuel frequently using medium sized wood e Burn large log rather than t
117. t to the sale of this product Wolf Steel will not be responsible for over firing downdrafts spillage caused by environmental conditions such as rooftops buildings nearby trees hills mountains inadequate vents or ventilation excessive venting configurations insufficient makeup air or negative air pressures which may or may not be caused by mechanical systems such as exhaust blowers furnaces clothes dryers etc Any damages to appliance combustion chamber heat exchanger or other components due to water weather damage long periods of dampness condensation damaging chemicals or cleaners will not be the responsibility of Wolf Steel Regular cleaning of the fine ash generated during the operation of this appliance is a necessary part of maintaining your appliance Failure of any components which is attributed to poor maintenance is not warrantable and will not be covered by this policy Wolf Steel reserves the right to have its representative inspect any TIMBERWOLF product or part thereof prior to honouring any warranty claim All parts replaced under the Limited Warranty Policy are subject to a single claim During the first 10 years Wolf Steel Ltd will replace or repair the defective parts covered by the lifetime warranty at our discretion free of charge From 10 years to life Wolf Steel Ltd will provide replacement parts at 5096 of the current retail price All parts replaced under the warranty will be covered for a period of 90 days fro
118. ts de fum e dans la pi ce via l appareil et les points de raccordement des conduits peut galement causer un blocage de la chemin e Un tirage trop grand provoquera des temp ratures excessives dans l appareil des composants de l appareil ou des conduits de raccordements qui rougeoient ou une combustion incontr lable qui peut causer un feu de chemin e ou des dommages permanents l appareil Ne faites pas fonctionner l appareil pendant plus de 30 minutes avec le contr le d air HIGH compl tement ouvert EXTINCTEURS ET D TECTEURS DE FUM E MONOXYDE DE CARBONE Toutes les maisons poss dant un appareil combustible solide devraient poss der au moins un extincteur d incendie dans un emplacement central connu de tous et au moins un d tecteur de fum e et d tecteur monoxyde de carbone plac dans la pi ce o l appareil est situ Si l alarme se d clenche corrigez la cause mais ne d sactivez pas ou ne relocalisez pas le d tecteur de fum e Si le d tecteur de monoxyde de carbone sonne l alarme d placer imm diatement une r gion qui a l air frais et appeler un votre service d incendie local COMBUSTIBLE 91 1A N ENTREPOSEZ PAS DE COMBUSTIBLE L INT RIEUR DES D GAGEMENTS DE L APPAREIL OU DANS L ESPACE REQUIS POUR LE REAPPROVISIONNEMENT EN COMBUSTIBLE ET LE RETRAIT DES CENDRES BR LER DU BOIS VERT OU HUMIDE PEUT CAUSER DES ACCUMULATIONS EXCESSIVES DE CREOSOTE LORSQU ALLUMEE ELLE PEUT CAUSER UN F
119. u ou des tablettes au dessus de l appareil Les temp ratures lev es sur le mur ou de l air au dessus de l appareil peuvent faire fondre d colorer ou endommager les d corations les t l viseurs ou autres composants lectroniques 3 17E 415 1464 04 22 15 45 2 1 DIMENSIONS 21 5 26 660 4mm 13 330 2mm 6 52 4 165 1mm 31 1 2 800 1mm 19 3 4 501 7mm 21 5 8 549 3mm Q EP22PA S 13 330 2mm E TI g 6 qaem 165 1mm 31 3 8 769 9mm 577 9mm 24 5 8 625 5mm 2 2 SP CIFICATIONS EP21LA S EP22PAS Sp cifications LARGEUR PROFONDEUR CENTRE DE LA BUSE JUSQU L ARRI RE CENTRE DE LA BUSE JUSQU AUX COTES 26 660 4 mm 21 5 8 549 3 mm 6 1 2 165 1 mm 13 330 2 mm 29 7 8 758 8 mm 26 660 4 mm 24 5 8 549 3 mm 6 1 2 165 1 mm 13 330 2 mm 29 7 8 758 8 mm HAUTEUR MODELE SUR PI DESTAL HAUTEUR MOD LE SUR PATTES 31 1 2 800 1 mm 31 3 8 800 1 mm 295 3 x 530 2 x 295 3 mm 371 5 x 530 2 x 295 3 mm 167 406 4 mm 167 406 4 mm Comme test en utilisant la m thode de test 28 Les figures varieront avec les conditions individuelles Wolf Steel Ltd unit BTU hr r aliste estim avec les journaux de feuillus et ranimer r gulier W415 1464 04 22 15 46
120. ue le feu de chemin e est teint et avant d allumer un autre feu nettoyez et inspectez la chemin e pour des signes de d t rioration ou des fissures V rifiez galement les mat riaux combustibles autour de la chemin e et du toit 85 1 8 4 NETTOYAGE DE LA CHEMIN E La chemin e et l appareil doivent tre inspect s et nettoy s s il y a lieu au moins une fois l an En cas d utilisation fr quente du chauffage au bois le nettoyage de la chemin e doit tre fait au besoin pour viter des feux de chemin e Les syst mes d vacuation des appareils combustion contr l e peuvent n cessiter un nettoyage aussi fr quent qu une fois par mois Cependant cette fr quence d pend des habitudes de chauffage de la personne qui utilise l appareil titre d exemple il est possible d obstruer la chemin e d un appareil combustible solide en quelques jours si l appareil br le lentement et que la chemin e est froide NOTE Les utilisateurs qui font toujours des feux chauds auront rarement d importantes accumulations de cr osote dans la chemin e Lors du nettoyage de la chemin e certains l ments doivent tre consid r s e Les outils appropri s doivent tre utilis s incluant une brosse sp cialement con ue pour le ramonage de la chemin e e Les conduits de raccordement le registre et la chemin e doivent tre nettoy s e La chambre de combustion et les d flecteurs doivent tre nettoy s au besoin e La chemin e
121. uill s etc plac s trop pres de l appareil pourraient prendre feu Il faut emp cher les enfants et les animaux de toucher l appareil quand il est chaud La chemin e doit tre en bon tat et ne pas tre f l e Avant d installer cet appareil contactez le service du b timent ou le service d incendie de votre municipalit et suivez leurs directives Faites fonctionner l appareil uniquement avec la porte bien ferm e Br lez le bois en arri re du pare b ches directement sur les briques AV RTI SS M r fractaires N utilisez pas un chenet et n essayez pas de sur lever le feu de quelque LA VITRE CHAUDE CAUSERA mani re Au moins 14 pouces carr s 90 3 centim tres carr s d air ext rieur doit tre DES BRULURES admis dans la ou directement dans l appareil par un conduit de 4 pouces NE PAS TOUCHER LA VITRE 101 6mm de diam tre e Cet appareil a t concu pour br ler du bois naturel uniquement Vous AVANT QU ELLE AIT REFROIDI obtenez une meilleure efficacit et des missions plus basses avec du bois NE JAMAIS LAISSER LES dur s ch qu avec du bois r sineux ou vert ou du bois dur fra chement ENFANTS TOUCHER LA VITRE coup N allumez pas votre feu l aide de produits chimiques ou de liquides tels que de l essence de l huile moteur etc Ne br lez pas de d chets des r sidus de tonte de pelouse de caoutchouc des HPBA produits p troliers r siduels
122. ure Crib Wood 2015 This wood appliance needs periodic inspection and repair for proper operation Consult the owner s manual for further information it is against federal regulations to operate this wood appliance in a manner inconsistent with the operating instructions in the owner s manual Cet appareil au bois doit faire l objet d une inspection et d un entretien p riodiques pour un fonctionnement ad quat Consultez le manuel d instructions pour plus d information Les r glements f d raux interdisent d utiliser cet appareil de chauffage d une mani re allant l encontre des instructions de fonctionnement contenues dans ce manuel Tr W415 1464 04 22 15 3 1 3 2 3 33 49 3 0 PLANIFICATION DE L INSTALLATION INSTALLATION DE L APPAREIL Faites installer votre po le par un d taillant autoris Si vous l installez vous m me faites v rifier vos plans d installation et ou l installation par votre d taillant Elaborez un plan d taill de l installation en y incluant les dimensions puis v rifiez les dimensions avec les exigences nonc es dans ce manuel Pour les enceintes d encastr lorsque vous d terminez l emplacement du po le localisez les montants du mur pour des vacuations horizontales Vous devrez possiblement ajuster la position du po le afin que l vent ne passe pas au m me niveau qu une pi ce de charpente Le po le doit tre positionn de facon ce qu aucun article combustible soit
123. ustion en laissant un espace minimum d un pouce l avant Ceci permettra aux r sidus des gaz de combustion d tre vacu s de la chambre de combustion Assurez vous que le joint de chevauchement ferme bien D Installez les 2 briques D l avant de l appareil EP22PA S A Installez les neuf briques et une brique B en commen ant par la partie arri re de l appareil comme illustr B Installez deux briques A sur chaque c t de l appareil Installez les quatre briques A et une brique E sur la paroi arri re en les faisant pivoter sous le support briques NOTE Placez les briques troites au centre C Pivotez soigneusement les d flecteurs en fibre F et installez les sur les tuyaux d air secondaire tel qu illustr Assurez vous que les d flecteurs sont compl tement pouss s vers l arri re de la chambre de combustion en laissant un espace minimum d un pouce l avant Ceci permettra aux r sidus des gaz de combustion d tre vacu s de la chambre de combustion Assurez vous que le joint de chevauchement ferme bien D Installez les 2 briques D l avant de l appareil EP21LA S EP22PA S 415 1464 04 22 15 3 7 EP21LA S ILLUSTRE INSTALLATION DU PARE CENDRES Pour viter des dommages pendant le transport le pare cendres t exp di dans la 63 W415 1464 04 22 15 64 6 0 INSTALLATION OPTIONNELLE 6 1 INSTALLATION DE LA SOUFFLERIE RISQUE D INCENDIE
124. utes obligations en ce qui concerne cette garantie en remboursant l acheteur d origine le prix de gros de toute pi ce garantie qui est d fectueuse Apr s la premi re ann e Wolf Steel It e ne sera pas responsable de l installation de la main d oeuvre ou autres co ts ou d penses relatives la r installation d une pi ce garantie et de telles d penses ne sont pas couvertes par cette garantie Nonobstant toutes les dispositions contenues dans cette Garantie Vie Limit e TIMBERWOLF la responsabilit de Wolf Steel sous cette garantie est d finie comme ci dessus et elle ne s tendra aucun dommage accidentel cons cutif ou indirect Cette garantie d finit l obligation et la responsabilit de Wolf Steel en ce qui concerne l appareil TIMBERWOLF Toute autre garantie nonc e ou implicite en ce qui concerne ce produit ses composants ou accessoires est exclue Wolf Steel n endosse ni n autorise aucun tiers assumer en son nom toute autre responsabilit concernant la vente de ce produit Wolf Steel ne sera pas responsable d une surchauffe des refoulements des d versements caus s par des conditions environnementales telles que des toits des b timents la proximit d arbres de collines de montagnes une ventilation ou des vents inad quats des configurations d vacuation excessives un apport d air insuffisant ou des pressions n gatives qui peuvent ou non tre caus s par des syst mes m caniques tels que les ventilateurs d
125. vert peine ferm 93 1 7 5 2 FEU CONTINU Chargez vos bitches de dimension plus grande de fa on compacte pour emp cher les flammes de s infiltrer compl tement Apr s 30 minutes environ selon la grosseur de la charge fermez le contr le de combustion en v rifiant que le feu ne se soit pas teint 7 6 SURCHAUFFEZ PAS L APPAREIL Une surchauffe peut se produire A B C en br lant de grandes quantit s de bois de dimension r duite tel que des rebuts de bois de meuble des palettes ou du bois trait en br lant vivement des grandes quantit s de bois avec le contr le de combustion HIGH enti rement ouvert pendant de longues p riodes une ou deux heures en faisant fonctionner l appareil lorsque la porte de la chute cendres est ouverte ou lorsque le joint d tanch it de la porte principale est d fectueux 821 PROBL MES DE FUM E Un appareil install convenablement ne devrait pas fumer Si le v tre fume v rifiez les points suivants Est ce que la chemin e a pu se r chauffer suffisamment Est ce que le passage de la fum e est bloqu soit dans la chemin e soit dans le conduit de raccordement soit dans l appareil Est ce que la piece est trop herm tique et que la prise d air comburant n est pas raccord e sur l ext rieur Es sayez avec une fen tre partiellement ouverte Est ce que le flot de fum e est restreint par un tuyau horizontal trop long ou par u
126. wo or three smaller e Fine Tune the air settings for optimum more reasonably sized logs performance e Burn at continually low setting if glass door is constantly blackened This means the firebox temperature is too low 87 1C W415 1464 04 21 15 36 9 0 REPLACEMENTS Contact your dealer or the factory for questions concerning prices policies replacement parts Normally all parts can be ordered through your Authorized dealer distributor FOR WARRANTY REPLACEMENT PARTS PHOTOCOPY OF THE ORIGINAL INVOICE WILL BE REQUIRED HONOUR THE CLAIM FAILURE TO POSITION THE PARTS When ordering replacement parts always give the following information IN ACCORDANCE WITH THIS e Model amp Serial Number of appliance MANUAL OR FAILURE TO USE ONLY e Installation date of appliance PARTS SPECIFICALLY APPROVED e Part number WITH THIS APPLIANCE MAY Description of part RESULT IN PROPERTY DAMAGE OR Finish PERSONAL INJURY IDENTIFIES ITEMS WHICH ARE NOT ILLUSTRATED FOR FURTHER INFORMATION CONTACT YOUR AUTHORIZED DEALER mi COMPONENTS i BRICK 4 5 114 3 X 9 228 6mm 3 Wogo 0168 Wo90 0168 BRICK 4 5 114 3mm X 6 250 158 8mm BRICK 4 5 114 3 X 7 625 193 7mm X 1 250 31 8mm BRICK 2 50 8mm X 9 228 6mm X 1 250 31 8mm BRICK 2 25 57 2mm X 9 228 6mm X 1 250 31 8mm BRICK 2 750 69 9mm X 9 228 6mm X 1 250 31 8mm
Download Pdf Manuals
Related Search
Related Contents
FP0 Analog I/O Unit Pistola de Pintura SGA-902 HL-1.1KFX Manual ボトル炭酸デポジットシステム取扱規則 Philips HTL2163B Liquivision Xeo - Scuba Diving Adviser Samsung Keraamilise emailiga DREAM Grill MWO, 23 L Kasutusjuhend Copyright © All rights reserved.
Failed to retrieve file