Home
Centrale di comando per motori battenti a 24V I
Contents
1. CB er rolling code receiver indicator e the upper line indicates the operation of the encoder of the first motor while the lower indicates the second 0 registered transmitters gt add transmitter adjust ement function AN NY tta h eadd transmtter me morisation radio controls aC el h memorisation of the rho radio control key on the first channel START impul rich se lt gt sbat e2ch memorisation of the radio control key on y rl the second channel PEDE STRIAN impulse To access the menus or to un dertake an operation press fma ENTER E and release imme diately Keeping the same but fmc ton pressed it will be possible to return to the upper menu or tser cancel the operation requested gt 3 3 gt o un co ro e gt e m ESC To navigate the menus end use the up and down arrows JOLT ENTER press and WARNING When navi release gating in the menus the control board will ignore ESC s prese fortwo any command to START seconds gt PPP default parameter erase 1 transmitter erase memory transmbters 8 00 00 instant power absorbed by motor 1 and motor 2 talano read code es Up learning the stroke eread code identific
2. GB m 9 e B Du sav 2 E312490 E Centrale di comando per motori battenti a 24V Control board for 24V swing motors Centrale de commande pour moteurs battants 24V Steuerzentrale f r Schwingfligelmotoren von 24V Central de mando para motores batientes a 24V SOLUTIONS Stagnoli T G srl Via Mantova trav 105A B 39 0309139511 39 0309139580 info stagnoli com www stagnoli com F gt E24 di Stagnoli la centrale di comando studiata per i motori battenti a 24V e i relativi accessori Realizzata solo con materiali di prima scelta amp stata progettata per avere bassi assorbimenti a riposo permettendo un netto risparmio energetico Particolare attenzione stata rivolta ai professionisti del settore facilitando la programmazione della centrale grazie a un display multilingua AVVERTENZE E NORME DI SICUREZZA Il presente manuale stato realizzato da Stagnoli per lo specifico utilizzo da parte di personale professionista e qualificato Si consiglia di leggere interamente il manuale di istruzioni prima di procedere all installazione del prodotto Durante l installazione non deve esserci la presenza di tensione sull impianto Gli impianti di cancelli automatici devono essere installati da per sonale tecnico qualificato e nel rispetto delle norme di legge Informare accuratamente l utilizzatore finale sulla modalit d uso su
3. 12 13 14 15 16 17 18 19 20 21 22 23 OV 24v Memoria establecimiento Display Botones de impostaci n Rel direccional motor 1 Rel direccional motor 2 Mosfet motor 1 Mosfet motor 2 Rel relampagueante Puentes diodos M dulo recibidor PTC 3A para electrocerradura de 12V Mosfet electrocerradura Tornillo salidas esp a cancela abierta SCA accesorios electrocerradura Rel esp a cancela abierta PTC 0 1A encoder Tornillo antena radio Jump borde resistivo Tornillo entrada borde Conector entradas mandos Conector encoder motor Connector motores relampagueantes Tornillo alimentaci n central a 24V Fusible 2 5A r pido electrocerradura esp a cancela abierto SCA o 5 5 2 2 LINEA gt gt ATENCION Unir el en TETS coder a la central respe 9 22 tando los colores de los 9 ES cables indicados 55 5 E gt a gt C E t 2 av gv mE la 24V ma mot mot2 25W Lao comun relampagueante para peatones comun start stop fotoc lulas en conclusi n Fotoc lulas en abertura y en conclusi n La l nea de alimentaci n 230V IN hacia el automatismo tiene que ser pro tegida por un interruptor magn tometrico o
4. D GB 8 The Stagnoli E24 is is the control board that has been studied for 24V swing mo tors and relative accessories Made using only prime quality materials it has been designed for low absorption at rest allowing a low consumption of electricity Particular attention has been paid to professionals in the sector making it easier to programme the board by using a multi language display WARNINGS AND SAFETY REGULATIONS This manual has been created by Stagnoli for specific use by pro fessional and qualified staff It is advisable to read the instruction manual completely before proceeding with installation During installation the system must not be live Automatic gate systems must be installed by qualified technical staff in compliance with legal requirements o Inform the end user in detail of the method of use residual dangers 1 the need for maintenance and the need to check safety devices at least once every six months CB AB d k N bi el h e h E 12 13 14 15 16 17 18 19 20 2 22 23 24 System memory Display Setting keys Directional relay motor 1 Directional relay motor 2 Mosfet motor 1 Mosfet motor 2 Flasher rela
5. 8 sensibilit anti crasement V rifier la fin de l installation que les forces d impact respectent la norme EN12453 et ser temps d activation de la serrure lectrique c est le temps exprim en secondes qui s coule entre la fermeture totale du portail et l intervention de la serrure lectrique La valeur de d faut programm e par Stagnoli est 2 et est r gla ble de O 7 secondes ATTENTION v rifier que l accrochage la serrure se fasse sans cr er de frictions et r gler le param tre t Ser en cons quence efend force finale de pouss e sur la but e c est la force que les moteurs exer cent en phase de fermeture une fois qu ils ont atteint les but es de fin de course Elle est exprim e en pourcentage par rapport la force maximum que les moteurs peuvent exercer La valeur de d faut programm e par Stagnoli est 30 et est r glable de 20 70 ATTENTION r gler fend une valeur basse si la structure du portail n est pas so lide Le r glage de ce param tre peut influencer le temps et la force avec lesquels le portail travaille durant la phase finale de sa course Fonctions a fermeture automatique fermeture automatique du portail apr s son ouver ture compl te 3 0 fonction non habilit e 1 fonction habilit e Programmer le r glage t t pour personnaliser le temps qui doit s couler entre la fin de l ouverture et le d but de la fermeture aut
6. Pages crans de diagnostic La centrale est en mesure de reconnaitre les probl mes ou les alarmes qui peuvent se produire sur l installation et pour lesquels elle peut signaler certains messages sur le display pour permettre de d terminer le probl me el rf activation de la commande de START sur le premier canal de radiofr quen ce el f activation de la commande de START sur le canal pi ton F gt eph0 activation de l entr e des photocellules en fermeture sur la plaque bor nes epho activation de l entr e des photocellules en fermeture et en ouverture sur la plaque bornes ebar activation du cordon de s curit t 0 impulsion de stop een Cl intervention du d tecteur encodeur sur le premier moteur eent intervention du d tecteur encodeur sur le second moteur e3 e activation de la commande d ouverture avec x ech activation de la commande de fermeture avec 0 ep ed activation de la commande d entr e pi tonne ea Ml activation du d tecteur anti crasement sur le moteur 1 ea M activation du d tecteur anti crasement sur le moteur 2 F A Q Les questions les plus fr quemment pos es Pourquoi choisir un metteur rolling code plut t qu un metteur code fixe Les metteurs rolling code sont consid r s plus s rs car ils ne peuvent pas tre clon s et ont plus de 200 millions de combinaisons qui changent chaque transmission Les metteur
7. vierte Bildschirmanzeige Zeigt den Lauf im Speicher an Diagnosebildschirm Die Zentrale kann Probleme oder Alarme erkennen die sich auf der Anlage erei gnen k nnen weshalb sie auf dem Hauptdisplay einige Meldungen anzeigen kann um die Individualisierung des Problems zu erm glichen el rf Aktivierung der Anweisung START auf dem ersten Funkfrequenzkanal e rf Aktivierung der Anweisung START auf dem FuBg nger Kanal eph0 Aktivierung des Fotozelleneingangs bei der SchlieBung auf dem Klemmen brett ephoA Aktivierung des Fotozelleneingangs bei der SchlieBung und der Offnung auf dem Klemmenbrett Aktivierung der Sicherheitsflanke est 0 Stopp Impuls een Cl Eingriff des Encoder Sensors auf dem ersten Motor een 2 Eingriff des Encoder Sensors auf dem zweiten Motor eape Aktivierung der Offnungsanweisung mit 0 C ech Aktivierung der Schliessanweisung mit 0 eped Aktivierung der Anweisung des Fussg ngereingangs ml Aktivierung des Quetschsicherheitssensors auf dem Motor 1 ea M2 Aktivierung des Quetschsicherheitssensors auf dem Motor 2 Technische Angaben eSpeisung der Automatik 230V 50 60Hz ePrim re Schutzsicherung Transformator T1 25A 230V eSchutzsicherung des Ausgangs Zubeh r 24V F2 5A Empf nger 433Mhz Maximales Fassungsverm gen 76 Funkco es eBetriebstemperatur 20 55 eMaximale Nennleistung der Motoren 70W 70W Maximale Leistung des Blinklich
8. attivazione del sensore antischiacciamento sul motore 1 9117 attivazione del sensore antischiacciamento sul motore 2 Dati Tecnici e Alimentazione dell automazione 230V 50 60Hz Fusibile di protezione primario trasformatore T1 25A 230V eFusibile di protezione dell uscita accessori 24V F2 5A eRicevitore integrato 433Mhz capienza massima 76 codici radio eTemperatura di funzionamento 20 55 ePotenza nominale massima dei motori 70W 70W ePotenza massima dell uscita lampeggiante 25W ePotenza massima dell uscita spia cancello aperto SCA 5W eDispositivo elettronico anti schiacciamento amperometrico ad encoder F A Q Le domande pi frequentemente poste Perch scegliere un trasmettitore rolling code piuttosto che uno a codice fisso trasmettitori rolling code sono da considerarsi pi sicuri in quanto non sono clonabili e hanno oltre 200 milioni di combinazioni che cambiano ad ogni trasmissione I tra smettitori a codice fisso invece dispongono di 1024 combinazioni di codici che non cambiano ad ogni trasmissione La centrale pu gestire il funzionamento del motore con le batterie di emergenza Si Per utilizzare le batterie di emergenza utilizzare l apposito kit fornito da Stagno La centrale non riconosce il trasmettitore Perch Accertarsi di utilizzare centrale e trasmettitori dello stesso tipo Nella prima schermata principale si pu verificare il tipo di ricevitore utilizzato dalla centrale ed
9. eha blocco impulsi durante l apertura la centrale ignora gli impulsi di START durante la fase di apertura ba 0 funzione non abilitata ba funzione abilitata ebp blocco impulsi durante la pausa la centrale ignora gli impulsi di START durante la pausa tra l apertura e la chiusura automatica t Ogni comando di START ricevuto durante la pausa tra l apertura e la chiusura automatica ricarica il tempo bp 0 funzione non abilitata bp 1 funzione abilitata Queste funzioni permettono al cancello di non bloccarsi o invertire la corsa a causa di altri comandi di START come ad esempio in contesti condominiali ecf chiusura rapida nel caso in cui vi sia un passaggio attraverso le fotocellule durante la fase di apertura o a cancello aperto il tempo della regolazione tt 3 se attivata e superiore ai 3sec viene automaticamente ridotta a 3sec cr funzione non abilitata cr 1 funzione abilitata 2p funzionamento apri chiudi 2p 1 funzione abilitata ad ogni impulso di F gt START il movimento del cancello inverte la direzione APERTURA CHIUSURA 2p 0 funzione non abilitata la sequenza di movimento del portone diventa APER TURA FERMATA t t ca CHIUSURA STOP 0 prelampeggio dopo il comando di apertura del cancello il lampeggiante si attiva per due secondi prima che venga iniziata la fase di apertura o di chiu sura 00 funzione non abilitata 0 1 funzione abilitata eS V
10. 8 portarsi sulla dicitura reset parametri del display e premere il tasto ENTER Verr visualizzato il messaggio RESE che lampegger fino a quando non sar confermata l intenzione di reimpostare tutti i parametri o di annullare l operazio ne parametri impostati di default sono t t Ca aped 70 sfaa l sfac 3 huit rch 20 sbat 5 y 81 fmla 50 fme 0 fm2a 50 2 51 tser 2 fend 30 ca l ba 0 bp 0 cr 0 pied sv 0 27 0 rezo m 0 en 55 0 ac 0 t 0 20 0 1 0 0 te 0 ecancela 1 radiocomando per cancellare il codice di un trasmettitore una volta entrati nel men cancella portarsi sulla dicitura cancela 1 radiocomando del di splay e premere il tasto ENTER Verr visualizzato il messaggio PREMI Premere a questo punto il tasto del trasmettitore da cancellare Se l operazione sar portata a M in maniera corretta verr visualizzato il messaggio In caso contra rio ecancela tutta memoria radio per cancellare tutti i trasmettitori registrati una volta entrati nel men cancela portarsi sulla dicitura cancela tutta memoria ra dio del display e premere il tasto ENTER Verr visualizzato il messaggio PRG che lampegger fino a quando non sar confermata l intenzione di cancellare tutti i codici registrati premendo il tasto ENTER o di annullare l operazione prolungan do la pressione dello stesso tasto N B Per portare a termine la cancellazione della memoria radio viene r
11. 885 M5 ECH 1 24 0 24 TRANSFORMATOR 0 230 5 STROMLEITSCHIENE MOTOR 2 ech MOTOR 1 E24 de Stagnoli es la central de mando estudiada para los motores batientes a 24V y los relativos accesorios Realizada s lo con materiales de primera selecci n ha sido proyectata para obtener bajas absorciones a reposo permitiendo un neto ahorro energ tico Particular atenci n ha sido dirigida a los hombres de carrera del sector facilitan do la programaci n de la central gracias a un display multilengua ADVERTENCIAS Y NORMAS DE SEGURIDAD El presente manual ha sido realizado por Stagnoli para el especi fico utilizo por parte del personal profesionista y calificado Se aconseja de leer interamente el manual de instrucciones antes de proceder a la instalaci n del producto Durante la instalaci n no tiene que haber tensi n sobre el esta blecimiento Los establecimientos de cancelas autom ticas tienen que ser in stalados por el personal t cnico calificado y en el respeto de las normas de ley Informar cuidadosamente el utilizador final sobre la modalidad de utilizo sobre la peligrosidad residua sobre la necesidad de la ma 2 nutenci n y sobre la necesidad de un control de los dispositivos de seguridad al menos cada seis meses AE a bi N pl evo
12. Es k nnen bis zu 76 Codes gespeichert werden Auf das Men 299 radiot zugreifen und zur Displayschrift Ih oder 201 gelan gen und den hinzuzuf genden Kanal ausw hlen Bei dem Dr cken von ENTER erscheint die Schrift premi Dr cken Sie die zu speichernde Taste An dieser Stelle zeigt das Display die Schrift 0k an wenn der Vorgang korrekt zu Ende gef hrt worden ist oder etr falls Speicherfehler aufgetreten sind oder ful wenn der Speicher des Empf ngers voll ist e Wenn man eine Antenne ausserhalb der Steuerung und vom Boden weit entfernt installiert verbessert sich die Sichtbarkeit zwischen Handsendern und Steverung Vergessen Sie bitte nicht dass Metallteile und Eisenbeton den Betrieb des Fun kempf ngers st ren wenn sie zwischen der Steuerung und dem Funkempf nger gestellt werden Einstellungen automatische Schliesszeit Es handelt sich hierbei um die Zeit die zwischen der vollst ndigen Offnung des Tors und seiner automatischen Schlies sung verl uft Wenn die Fotozelle verdeckt ist wird die tt C Zeit von dem Au genblick an gez hlt in dem die Fotozelle freigegeben wird Die von Stagnoli eingegebene Standardzeit ist 10 Sekunden und kann von 1 bis 240 Sekunden eingestellt werden eaped ffnung Fussg nger Es handelt sich hierbei um die in Zentimetern au sgedr ckten Lange des Wegs der teilweisen Offnung bzw der Modalit t Fu g n ger Die von Stagnoli eingegebene Standardzeit ist 70 und kann vo
13. Geringe Werte f r fma fmk fm2a und zeigen eine gr ssere Quetschsi cherheitsempfindlichkeit an Am Ende der Installation ist zu pr fen dass die Anschlagskr fte die Norm EN12453 beachten et ser Aktivierungszeit Elektroschloss Dies ist die in Sekunden angegebene Zeit die zwischen der vollst ndigen Schliessung des Tors und dem Eingriff des Elektroschlosses verl uft Der von Stagnoli eingegebene Standardwert ist 2 und kann von 0 bis 7 Sekunden eingestellt werden ACHTUNG Es ist zu pr fen dass das Einschnappen des Schlosses ohne Reibun gen erfolgt und der Parameter t Ser ist dementsprechend einzustellen efend Abschliessende Stosskraft im Anschlag Dies ist die Kraft die die Motoren in der Schliessphase ausf hren nachdem sie die Anschlage des Endschalters er reicht haben Sie wird mit Bezug auf die Maximalkraft die die Motoren aus ben k nnen in Prozenten angegeben Der von Stagnoli eingegebene Standardwert ist 30 und kann von 20 bis 70 eingestellt werden ACHTUNG Falls die Struktur des Tors nicht stabil sein sollte ist fend mit einem geringen Wert einzustellen Die Einstellung dieses Parameters kann Zeit und Kraft beeinflussen mit der das Tor in der anschliessenden Phase seines Wegs arbeitet Funktionen automatische Schliessung Automatische Schlie ung des Tors nach seiner vollst ndigen Offnung Ca 0 Funktion nicht aktiviert 1 Funktion aktiviert F r die individuelle Zeit die
14. gt ev gt D T gt T E E et la rel cher rapidement 55 En prolongeant la pression sur la touche il sera possible de 0C retourner au menu sup rieur ou d annuler l op ration deman d e fonction ESC Pour naviguer dans les menus utiliser les touches fl che AATTENTION Pour le haut et fl che en bas sch ma de navigation du menu en anglais voir les instructions dans les tres langues JOLI fonction ENTER ATTENTION Durant O simple pression navigation dans les me nus la centrale ignore les A commandes de START et JO LEX fonction ESC PIETION pression de deux secondes 8 00 00 puissance instantan e absorb e par le moteur 1 et par le moteur 2 apprendimento leggi codice eapprendiment 0 apprentissage de la course leggi codice identification et reconnaissance metteurs talano english reset parametri cancela 1 radiocomando cancela tutta memoria rado et C temps de fermeture automatique ea 061 ouverture pi tonne eS d temps de retard en ouverture du moteur 2 5 temps de retard en fermeture du moteur 1 e Ji course ralentie en ouverture er h course ralentie en fermeture es h espace de but e eV TE vitesse de ralentissement ef mb force anti crasement du moteur 1 en ouverture ef
15. These functions allow the gate not to block or reverse the stroke due to other START commands in condominium use for example ecr rapid closing if there is a passage through the photocells during the ope ning phase or with the gate open the regulation time t t 8 if activated and gre ater than 3 secs is automatically reduced to 3 secs cr 0 function not enabled cr 1 function enabled 2p open close operation 2p 1 function enabled at each START impulse the movement of the gate changes direction OPENING CLOSING 2p 0 function not enabled the gate movement sequence becomes OPENING CLOSING tt ca CLOSING STOP 0 preflashing after the START signal the flasher or courtesy light activates for two seconds before the opening or closing phase begins DI 0 function not enabled 0 1 function enabled GB F gt eS V suction lock activating this function at the start of the opening manoeuvre a 12V suction lock is controlled after an activation time regulated by the parame ter t Ser sv 0 function not enabled the exit is activated only for t ser time sV 1 function enabled the exit remains active and deactivates only for the t ser time ramming on opening before starting the opening manoeuvre motor 1 pu shes the door in closing for two seconds allowing the electric lock to move away from the fastener At this point the lock is activated and the manoeuvre continues its
16. de START e2ch memorizaci n del bot n radiodirigido sobre el segundo canal impulso PARA PEATONES Para acceder a los men o para una operaci n pulsar el bot n ENTER E dejandolo regolazioni AN aped velozmente Prolongando la fmc presi n sobre el mismo bot n ser posible regresar al men tser ipea o anular la operaci n soli citada funci n ESC Para navigar en los menu usar los botones flecha arriba y fle cha abajo ATENCION Para el esquema de la navigaci n del men en ingl s ver las instrucciones en los otros idiomas 1 funci n ENTER presi n simple funci n ESC presi n de dos segundos funzioni a n 2 V l s omm b e A rri 2 del 2 J E 3 a la central ignora los man dos de START F 00 00 potencia instantanea absorbida por el motor 1 y por el motor 2 apprendimento leggi codice eapprendiment 0 conocimiento de la corrida 2001 codice identificaci n y reconocimiento transmetidores reset parametri cancela tutta memoria rado et tiempo de conclusi n autom tica 94 pet abertura para peatones eS 144 tiempo de retraso en abertura del motor 2 esfa tiempo de retraso en conclusi n del motor 1 er d corrida moderada en abertura er corrida moderada en conclusi n es
17. force anti crasement du moteur 1 en fermeture e m2 force anti crasement du moteur 2 en ouverture m force anti crasement du moteur 2 en fermeture f Uazo et 5 f temps d activation de la serrure lectrique efend force finale de pouss e sur la but e e fermeture automatique eh blocage des impulsions durant l ouverture blocages des impulsions durant la pause C fermeture rapide fonctionnement ouvre ferme e l pr clignotement eS V serrure ventouse e l coup de b lier en ouverture ef conomie d nergie elm fonctionnement avec un moteur een fonctionnement encodeur eS 5 soft start fonctionnement open close elt inversion totale apr s la rencontre d un obstacle 2 deux cordons de s curit ecf fonctionnement du r cepteur code fixe 3 alarme et contr le diagnostic avant chaque d part ereset p rametri programmation des param tres d usine ecancela 1 radocomando effacement d un metteur ecancela tutta memoria radio effacement de tous les metteurs enregistr s he Ajout de radiocommandes Avant de m moriser un metteur s assurer qu il soit compatible avec la typolo gie de r cepteur int gr lors de la premi re visualisation du display l apparaitra si il s agit dun r cepteur en modali rolling code ou f si il s agit d un r cepteur en modalit code fixe Le r cepteur peut m moriser des codes r
18. loro corsa e presentati nella seconda schermata principale del display Se l opera zione sar portata a termine in maniera corretta verr visualizzato il messaggio OK In caso contrario ERR 8 ATTENZIONE durante le manovre di apprendimento la centrale ignora i coman di di START e PEDONALE e lavora con i parametri di forza impostati Anche se rimangono attive le sicurezze assicurarsi che non vi siano oggetti o persone sulla traiettoria di lavoro del serramento Leggi codice E possibile verificare se un codice sia gi stato memorizzato Posizionandosi sulla dicitura leggi codice e premendo il tasto ENTER sul display verr visualizzato il messaggio PRE MI Premendo a questo punto il tasto del trasmettitore che si deside ra verificare verranno visualizzate una serie di schermate descrittive del codice eprima schermata 5 r 0lo f 01 Il primo carattere indica il produttore del radiocomando dove 5 indica Stagnoli e un produttore generico secondo carattere indica la tipologia di codice dove indica rolling code ef codice fisso Gli ultimi due caratteri indicano il codice del tasto premuto eseconda schermata H 00 dove H indica la parola posizione e la cifra suc cessiva progressiva da O a 75 indica la posizione occupata dal trasmettitore in memoria Nel caso il trasmettitore non sia presente in memoria apparir sul display eterza e quarta schermata verr visualizzat
19. pedonale comune start stop fol otocellule in apertura e in chiusura fotocellule in chiusura La linea di alimentazione 230V iN verso l automatismo deve essere protetta da un interruttore magnetometrico oppure da una coppia di fusibili da 5A Un inter ruttore differenziale consigliato ma non indispensabile se gi presente a monte dell impianto Alimentare l automatismo attraverso un cavo da 3x1 5mm fase neutro terra Se la distanza fra la centrale e la connessione all impianto di terra supera i 30m neces sario prevedere un dispersore di terra in prossimit della centrale I cablaggi devono essere effettuati a centrale spenta Gli ingressi dei contatti di tipo N C normalmente chiuso se non utilizzati vanno ponticellati con un morsetto comune 24V Se per lo stesso ingresso ci sono pi con tatti N C questi vanno posti in serie tra di loro esempio ph e ph2 nello schema Gli ingressi dei contatti di tipo N O normalmente aperto se non usati vanno la sciati liberi Se lo stesso ingresso ci sono pi contatti N O questi vanno posti in parallelo tra di loro esempio stl st2 nello schema 8 Procedura operativa al primo avvio eEffettuare i eeh elettrici richiesti dall impian to e controllarli a scheda spenta T eAccertarsi che i fermi meccanici siano installati _ display JOLT correttamente e il cablag
20. Absorptionen zu haben wodurch eine deutliche Energieersparnis erm glicht wird Besondere Aufmerksamkeit ist auf die Fachleute der Branche gerichtet worden indem die Programmierung der Zentrale durch ein mehrsprachiges Display ve reinfacht worden ist WARNUNGEN UND SICHERHEITSVORSCHRIFTEN Das vorliegende Handbuch ist von Stagnoli f r den spezifischen Gebrauch von qualifizierten und Fachpersonal realisiert worden Es wird empfohlen das Bedienungshandbuch vor der Installation des Produkts vollst ndig zu lesen e W hrend der Installation darf keine Spannung auf der Anlage vorhanden sein Die Anlagen der automatischen Tore m ssen von technischem Fa chpersonal und unter Beachtung der gesetzlichen Bestimmungen installiert werden Der Endverbraucher ist sorgf ltig ber die Bedienungsweise die Rest 1 gefahr die Wartungsanforderungen und ber die Notwendigkeit einer Kontrolle der Sicherheitsvorrichtungen zu informieren die mindestens alle sechs Monate erfolgen muss AE a bi NAME 12 13 14 15 16 17 18 19 20 21 22 23 OV 24v Anlagenspeicher Display Einstellungstasten Richtungsrelais Motor 1 Richtungsrelais Motor 2 Mosfet Motor 1 Mosfet Motor 2 Blinkrelais Diodenbr cke Empf ngermodul PTC 3A f r Elektr
21. Dal espacio de golpe ev velocidad de moderaci n ef mh fuerza anti aplastamiento motor 1 en abertura ef fuerza anti aplastamiento motor 1 en conclusi n fm fuerza anti aplastamiento del motor 2 en abertura d Ma fuerza anti aplastamiento del motor 2 en conclusi n Uazo et 5 67 tiempo de activaci n de la electrocerradura efend fuerza final de empuj n en golpe conclusi n autom tica eh bloquea impulsos durante la abertura 0 bloquea impulsos durante la pausa e conclusi n r pida e funcionamiento abre cierra epi prerelampagueo eS V cerradura a ventosa e l golpe de aries en abertura ef ahorro energ tico elm funcionamiento con un motor een funcionamiento encoder eS 5 soft start C funcionamiento open close elt inversi n total despu s de haber encontrado un obst culo 2 dos bordes de seguridad ec funcionamiento del recibidor a c digo fijo ea l alarma et control diagnostico antes de cada salida ereset p rametri impostaci n de los parametros de fabrica ecancela 1 radiocomando cancelaci n de un transmetidor ecancela tutta memoria radio cancelaci n de todos los transmetidores registrados DI epp ue gt gs Adjunta radiodirigidos Antes de memorizar un transmetidor asegurarse que sea compatible con la tipologia de recibidor integrado en la primera visualizaci n del
22. Tors wird OFFNUNG HATT tt ca SCHLIESSUNG STOPP Vorblinken Nach der Anweisung f r die ffnung des Tors wird das Blinklicht oder das Begr ungslicht zwei Sekunden vor Beginn der Offnungs oder Schlief3 phase aktiviert 00 Funktion nicht aktiviert DEI Funktion aktiviert es V Saugschloss Mit der Aktivierung dieser Funktion zu Beginn der Offnung sbewegung wird nach einer Aktivierungszeit die von dem Parameter tser gere gelt wird ein Elektroschloss von 12V gestevert V 0 Funktion nicht aktiviert der Ausgang wird nur f r die Zeit tser aktiviert 1 Funktion aktiviert der Ausgang bleibt aktiv und wird nur f r die Zeit t er ausgeschaltet ear Widderstoss Offnung Vor Beginn der Offnungsbewegung dr ckt der Mo tor 1 den sich schliessenden Schwingfl gel f r zwei Sekunden wodurch es dem Elektroschloss erm glicht wird sich von der Sperre zu entfernen An dieser Stelle wird das Schloss aktiviert und die Bewegung f hrt regul r mit der Offnung fort ar 0 Funktion nicht aktiviert ar Funktion aktiviert er Energieersparnis Hiermit bleiben die Fotozellen bei nicht aktiver Anlage ausgeschaltet wodurch Energie gespart wird Auf diese Weise bleiben die Foto zellen nur w hrend der Bewegung der Schwingfl gel und f r die in der Einstel lung tcor eingestellte Zeit aktiv re 0 Funktion nicht aktiviert Funktion aktiviert Schliessen Sie die Versorgung 24V des Senders und des Empf
23. abertura y el inicio de la conclusi n autom tica Si Ca 1 y 2p 0 un mando de START activado mientras las puertas est n en abertura detiene las partes y carga el tiempo tt de conclusi n autom tica eha bloque impulsos durante la abertura la central ignora los impulsos de START durante la fase de abertura ba 0 funci n no habilitada ba 1 funci n habilitada ebp bloque impulsos durante la pausa la central ignora los impulsos de START durante la pausa entre la abertura y la conclusi n autom tica Cada man do de START recibido durante la pausa entre la abertura y la conclusi n autom ti ca recarga el tiempo t t C 0050 funci n no habilitada bp 1 funci n habilitada Estas funciones permiten a la cancela de no bloquearse o de invertir la corrida causa de otros mandos de START como por ejemplo en contextos condominia es ecr conclusi n rapida en el caso en que haya un pasage a trav s de las fotoc lulas durante la fase de abertura o a cancela abierta el tiempo de la re gulaci n tt 8 si activada y superior a los 3569 viene autom ticamente reducta a 3seg 8 cr 0 funci n no habilitada cr 1 funci n habilitada 2p funcionamiento abre cierra 2p 1 funci n habilitada a cada impulso de START el movimiento de la cancela invierte la direcci n ABERTURA CONCLU SION 2p 0 funci n no habilitada la sequencia de movimiento del port
24. antes que uno fijo Los emisores rolling code se consideran m s seguros siendo que no se pueden du plicar y disponen de 200 millones de combinaciones diferentes cada emisi n En cambio los emisores a c digo fijo disponen de 1024 combinaciones de c digos que quedan invariados durante cada emisi n gla central puede gestir el funcionamiento del motor con las bacterias de emergen cia Si Para utilizar las bacterias de emergencia utilizar el adecuado kit suministrado por Stagnoli La central no reconoce el transmetidor sPorqu Acertarse de utilizar central y transmetidores del mismo tipo En la primera pantalla principal se puede verificar el tipo de recibidor utilizado desde la central y eventual mente cambiarlo planteando dde nuevo el parametro Cf Al llegar a la condici n de paro la automaci n invierte el moto en vez de pararse aPorqu Una de las causas que determinan la p rdida de los datos memori zados sobre la centralita es la activaci n de la automaci n mientras se encuentra bloqueada Para permitir que la centralita recupere los datos de codifi caci n ser suficiente quitar la tensi n verificar que la automaci n sea bloqueada y volver a alimentar la central de mando Al primer impulso de start la misma central de mando recuperer los datos E ELECTROCERRADURA ESPIA CANCELA s sa ABIERTA gem mg 40 GEI KA og 0 24 o d g
25. conclusi n La corrida planteada de default por Stagnoli es 20cm y es regulable de O a 70cm para puertas de 1 8m ATENCI N antes de plantear las moderaciones controlar que la cancela sea balanceada de manera correcta Durante sta fase en efecto los motores tienen menos fuerza y la impostaci n de ste parametro puede influir sobre el grado de seguridad del establecimiento mismo Controlar terminada la regulaci n de stos parametros las fuerzas del establecimiento de las puertas es hat espacio de golpe es el espacio centimetros antes del golpe en aber tura o en conclusi n durante el cual la central interpreta los obst culos como fin corrida y se detiene El espacio planteado de Stagnoli es de 5cm y es regulable de 1 a 10cm ATENCION la impostaci n de ste parametro puede influir sobre el grado de se guridad del establecimiento mismo La instalaci n tiene que ser efectuada respe tando las cuotas de seguridad de manera que se pueda mantener ste parametro el m s bajo posible y el establecimiento seguro ev velocidad de moderaci n son los valores relativos a la velocidad con la cual los motores obran en fase de moderaci n El valor planteado de default por Stagnoli es 3 y es regulable de 1 a 4 donde el valor m s bajo indica una baja velocidad y 4 indica una velocidad par a casi la mitad de la velocidad operativa de los motores efml fuerza anti aplastamiento del motor 1 en abertura es la fuerza ant
26. display apare si se trata de un recibidor en modalidad c digo fijo El recibidor puede memorizar c digos rolling code de tipo HCS300 STAGNOLI con miliardos de combinaciones o c digos fijos de tipo HT53200 a 13 bit o la parte fija de un c digo rolling code 28 bit SN Es posible memorizar hasta 76 c digos Entrando en el men 200 radioc llevarse sobre la escrita a display Lh o 2ch y escoger el canal que se quiere agregar Pulsando ENTER desde luego vendr visualizada la escrita Pr emi premios Pulsar el bot n que se desea memorizar en ste momento el display visualizar la escrita 0k si la operaci n viene concluida de manera correcta f en el caso se verifiquen errores de registraci n o full si la memoria del recibidor est llena e Al instalar una antena al exterior de la central y cerca del suelo el area de visi bilidad entre emisores y central aumenta Adem s no olvidense que los compo nentes met licos y de hormig n armado si se ponen entre la central y el receptor reducen la recepci n de ste Regulaciones et tiempo de conclusi n autom tica es el tiempo que transcurre entre la abertura completa de la cancela y su conclusi n que sucede en manera autom ti ca Si la fotoc lula est ocupada el tiempo de tta viene calculado desde el momento en el cual la fotoc lula se desempe a El tiempo plantetado de default por Stagnoli es 10seg y es regulable de 1 hasta 240seg eaped ab
27. display shows r if the receiver is in rolling code mode or f if the receiver is in fixed code mode The receiver can memorise rolling codes type HCS300 STAGNOLI with billions of combinations or fixed codes type HT53200 with 13 bits or the fixed part of a rolling code 28 bit SN It is possible to memorise up to 76 codes Enter the menu add transmitter move over the wording display IN or 2ch eand select the channel that is to be added Press ENTER the wording premi press will appear Press the key that must be memorised at this point the display shows the wording 0k if the operation has been carried out correctly err if there are registration errors or full ifthe receiver memory is full An external antenna installed far from the ground increases the visibility betwe en the transmitter and the receiver The power of the receiver can be reduced if metal parts or reinforced concrete are placed next to it Regulating et automatic closing time this is the time from when the gate is fully open to when it is closed automatically If the photocell is engaged the tt 8 time is counted from the time when the Geet is freed The detail time set by Stagnoli is 10 secs and it can be regulated from 1 to 240secs eaped pedestrian opening this is the length of the stroke stated in centimetres of the partial opening namely the pedestrian mode The default value set by Stagno li is 70 and it can be regulated from 30 to 150 In case of
28. efm2a anti crushing force of motor 2 in opening this is the anti crushing force of the second leaf of the gate stated in percentage compared with the maximum force that the same can generate The default value set by Stagnoli is 50 and it can be regulated from 20 to 99 efm2 anti crushing force of motor 2 in closing This is the anti crushing force of the second leaf of the gate stated in percentage compared with the maximum force that the same can generate The default value set by Stagnoli is 50 and it can be regulated from 20 to 99 WARNING The way these two parameters are set can influence the level of safety of the system itself Stagnoli advises setting this parameter with a safety margin that is at least 10 compared with the maximum current consumed by the motors in the opening and closing phases respectively This is shown during the motor stroke on the display in the second main screen fma and fm2c with low values indicate greater anti crushing sensiti vity At the end of installation check that the force of impact is in compliance with the regulation EN12453 et ser electric lock activation time this is the time stated in seconds going from the time of total closure of the gate to the activation of the electro lock The de fault value set by Stagnoli is 2 and it can be regulated from O to 7 seconds GB 8 WARNING check that the lock catches without creating fricti
29. en 0 the command PEDESTRIAN opening allows the door controlled by motor 1 to open completely 5122 motor 2 opening delay time In the opening phase the second motor delays its start The default time set by Stagnoli is 1 and can be regulated from O to 10 seconds esfac motor 1 closing delay time In the closing phase the first motor delays its start The default time set by Stagnoli is 3 and can be regulated from 0 to 10 seconds WARNING before setting the slowing phase check that the gate has been ba lanced correctly In this phase the motors have less power and the way this parameter is set can influence the level of safety of the system itself Once these parameters have been regulated check the force of impact of the gate leaves er l p slowed stroke in opening the control board slows down the stroke of the motors in the end part of its opening phase The default stroke set by Stagnoli is 20 cm and it can be regulated from O to 70cm for 1 8m gate wing erkh slowed stroke in closing the control board slows down the stroke of the motors in the end part of its closing phase The default stroke set by Stagnoli is 20 cm and it can be regulated from O to 70cm for 1 8m gate wing WARNING before setting the slowing phase check that the gate has been instal GB F gt led correctly In this phase the motors have less power and the way this parameter is set can influence the level of safety of the system its
30. et PIETION et travaille avec les param tres de force programm s M me si les s curit s restent actives s assurer qu il n y ait pas d objets ou de personnes sur la trajectoire de travail du portail Effectuer quelques cycles d essai en v rifiant le fonctionnement correct de toute l installation e Effectuer les mesures de la force d impact du portail selon ce qui est sp cifi par les normes EN12445 Apr s une coupure d lectricit durant la man uvre d ouverture ou de fer meture de l automation la premi re commande de START commandera la ferme ture totale pour rechercher les but es d arr t Attendre donc que la man uvre e fermeture jusqu la but e soit termin e et programmer alors les nouvelles commandes 8 er indicateur r cepteur ralling code e le trait sup rieur indique le fo nctionnement de l encodeur du 11 lt premier moteur et le trait inf rieur celui du second encodeur ug metteurs enregistr s funzioni AW NY EN NN eagg radioc mise en m sfac moire des radiocommandes a el mise en m moire de la touche radiocommande sur le premier canal impul rich sion de START 0 fa fa e h mise en m moire de la touche radiocommande sur le second canal impul sion PIETION Pour acc der aux menus OU pour effectuer une op ration fma appuyer sur la touche ENTER no wn ro
31. fisso Il ricevitore pu memorizzare codici rolling code di tipo 5300 STAGNOLI con miliardi di combinazioni o codici fissi di tipo HT53200 a 13 bit o la parte fissa di un codice rolling code 28 bit SN E possibile memo rizzare fino a 76 codici eEntrando nel men 200 radio portarsi sulla scritta a display kh o 2th e scegliere il canale che si vuole aggiungere Schiacciando ENTER verr poi vi sualizzata la scritta Pr emi Premere il tasto che si desidera memorizzare a questo punto il display visualizzer la scritta 0k se l operazione viene portata a termine in maniera corretta nel caso si verifichino errori di registrazione o full se la memoria del ricevitore piena e nstallando un antenna esternamente alla centrale e lontana dal suolo l area di visibilit tra trasmettitori e centrale aumenta Ricordarsi inoltre che parti me talliche e cemento armato se posti tra la centrale e il ricevitore diminuiscono la capacit di ricezione di quest ultimo Regolazioni et tempo di chiusura automatica il tempo che intercorre tra l apertura completa del cancello e la sua chiusura che avviene in modo automatico Se la fotocellula occupata il tempo di tt viene conteggiato dal momento in cui la fotocellula si disimpegna Il tempo impostato di default da Stagnoli 10sec ed regolabile da 1 a 240sec eaped apertura pedonale la lunghezza della corsa espressa centimetri dell apertura parziale ossi
32. fixed part of a rolling code 28 bit SN eal alarm Alarm signalling that the gate has remained open This function activates the SCA output after 20 seconds have passed from the end of the time regulated by t t C and the gate is still open al 0 function not enabled 8l 1 function enabled ete test A diagnostics test is carried out to check the integrity of the encoder and amperometric sensors before each time the motors are started te 0 function not enabled te 1 function enabled Cancel edefault parameter to cancel the regulation parameters and those of regulated functions and reset the factory settings enter the menu cancel go to def a it pa ramet er on the display and press ENTER The message RESE is shown it flashes until the decision to reset all the parameters is confirmed or the operation is can celled The default parameters are t t 8 z 1 gen sfac 3 rlap 20 rich 20 sbat 5 v Ki fmb 50 fmiz50 fm2az50 fm2c 50 tser 2 fend 30 ca 1 ba 0 bp 0 cr 0 2p 0 1 520 ar 0 re 0 In 0 en 55 0 ac 0 t 0 20 0 cf 0 al 0 te 0 eerase I transmiter to cancel a transmitter code enter the menu delte then go to the wording erase 1 transmitter on the display and press ENTER The message PRE MI PRESS will appear Now press the key of the transmitter that must be cancelled If the operation has been carried out correctly the message OK will appear If this has not been carried put correctly the message E
33. impostare i rallentamenti controllare che il cancello sia installato in maniera corretta Durante questa fase infatti i motori hanno meno forza e l impostazione di questo parametro pu influire sul grado di sicurezza dell impianto stesso Controllare terminata la regolazione di questi parametri le forze di impatto delle ante es hat spazio di battuta lo spazio centimetri prima della battuta in apertu ra o in chiusura durante il quale la centrale interpreta gli ostacoli come fine corsa e si ferma La spazio impostato di default da Stagnoli amp di 5cm ed regolabile da 1 a 10cm ATTENZIONE l impostazione di questo parametro pu influire sul grado di sicu rezza dell impianto stesso l installazione deve essere effettuata rispettando le quote di sicurezza in modo da mantenere questo parametro il pi basso possibile e l impianto sicuro ev velocit di rallentamento sono i valori relativi alla velocit con cui i motori operano in fase di rallentamento Il valore impostato di default da Stagnoli 3 ed regolabile da 1 a 4 dove il valore pit basso indica una bassa velocit e 4 indica una velocit pari a circa la met della velocit operativa dei motori efml forza anti schiacciamento del motore 1 apertura la forza anti schiac ciamento della prima anta del cancello espressa in percentuale rispetto alla forza massima che lo stesso pu erogare Il valore impostato di default da Stagnoli 50 ed reg
34. intervertis sent le mouvement et ferment totalement le portail En phase de fermeture si ils rencontrent un obstacle il intervertissent le mouvement et s ouvrent compl tement Si la fonction n est pas active en phase d ouverture les moteurs s arr tent si ils rencontrent un obstacle alors qu en phase de fermeture ils intervertissent le mou vement 50 cm avant de s arr ter it 0 fonction non habilit e it 1 fonction habilit e 920 deux cordons de s curit Fonctionnement avec deux cordons de s curit 8k2 reli s en parall le 2b 0 fonction non habilit e 2b fonction habilit e ecf fonctionnement du r cepteur int gr code f 0 r cepteur fonction nant avec les codes rolling code cf 1 r cepteur fonctionnant avec les codes fixes Le fonctionnement code fixe ou rolling code du r cepteur est affich aussi sur la page cran initiale du display o 00 indique le fonctionnement rolling code etf 00 code fixe Le r cepteur peut m moriser des codes rolling code de type HCS300 STAGNOLI avec des milliards de combinaisons ou des codes fixes de type HT53200 13 bit ou la partie fixe d un code rolling code 28 bit SN alarme Alarme qui signale que le portail est rest ouvert Cette fonction ac tive la sortie SCA 20 secondes apr s la fin du temps r gl par tt 8 et le portail r sulte encore ouvert al 0 fonction non habilit e al fonction habilit e ete test u
35. les 30m il est n cessaire de pr voir un d perditeur de terre en proximit la centrale Les c blages doivent tre effectu s quand la centrale est teinte les entr es des contacts de type N C normalement ferm si non utilis es doivent tre pont es avec une borne commune 24V Si pour la m me entr e il y a plusieurs contacts N C ceux ci doivent tre mis en s rie entre eux exemple phl et ph2 sur le sch ma Les entr es des contacts de type N O normalement ouvert si non utilis es doivent tre laiss es libres Si pour la m me entr e il y a plusieurs contacts N O ceux ci doivent tre mis en parall le entre eux exemple st et st2 sur le sch ma 8 Proc dure d op ration la premi re mise en marche Effectuer les c blages lectriques voulus pour l in stallation et les conir ler quand la carte est tein 7 E te 3 or J display OLT eS assurer que les but es m caniques soient instal l es correctement et que le c blage des deux mo OL teurs aux encodeurs respectifs ait t effectu D D bloquer le portail et en contr ler le mouvement LED de presence O E les vantaux ne doivent pas rencontrer d obstacles r seau lectrique sur leur parcours La course du vantail ne doit pas pr senter de points durs durant le mouvement qui doit tre fluide Bloquer le portail et
36. n se vuelve ABERTURA PARADA tt CONCLUSION PARADA 0 prelampagueo despu s del mando de abertura de la cancela la luz se ac tiva por dos segundos antes que empieze la fase de abertura o de conclusi n DI 0 funci n no habilitada 0 1 funci n habilitada SV cerratura a ventosa activando sta funci n al principio de la manovra de abertura viene mandada una electrocerradura a 12V despu s de un tiempo de activaci n regulado desde el parametro t 5er sV 0 funci n no habilitada la salida se activa s lo para el tiempo t ser sv 1 funci n habilitada la salida permane activa y se desactiva s lo para el tiempo t Ser eal golpe de aries en abertura antes de empezar la maniobra de abertura el motor 1 empuja la parte final por dos segundos perimitiendo al electrocerradura de dejar la parada En ste preciso momento la cerradura se activa y la manio bra sigue regularmente en abertura ar 0 funci n no habilitada ar funci n habilitada er ahorro energ tico mantiene las fotoc lulas apagadas mientras el estableci miento no es activo permitiendo ahorros energ ticos Las fotoc lulas as perma nen activas s lo durante el movimiento de las puertas y durante el t t ca re 0 funci n no habilitada re 1 funci n habilitada Unir la alimentaci n 24V ya del transmitidor que del recibidor de las fotoc lu las a la salida del relampagueante elm un motor funcionamiento del estableci
37. ngers der Foto zellen an den Ausgang des Blinklichts an em ein Motor Betrieb der Anlage nur mit dem Motor 1 Im 0 Funktion nicht aktiviert M 1 Funktion aktiviert 8 een Encoder Betrieb Erm glicht den Betrieb des Systems auch im Falle eines Encoder Defekts das Tor wird kurz nach dem Start blockiert und auf dem Display erscheint die Schrift ENC oder ENC2 en 0 Encoder nicht aktiviert en Encoder aktiviert ACHTUNG Der Betrieb des Systems ohne Encoder ist als eine Notfallverwaltung anzusehen In dieser Modalitat wird bei jedem Hindernis auf das die Motoren treffen eine Bewegungsumkehrung von etwa 30 cm angewiesen ess Soft Start Gestattet den Motoren die Durchf hrung eines sanften Starts mit geringer Geschwindigkeit um die Beanspruchung der mechanischen Anlagentei le zu verringern Mit der Aktivierung dieser Funktion geben die Motoren in ihrer Startphase eine geringere Kraft ab 55 0 Funktion nicht aktiviert 5 Funktion aktiviert 0 Betrieb Open Close Der Eingang in das Klemmenbrett von START wird OPEN und der Eingang in das Klemmenbrett von PEDONALE Fussg nger wird CLOSE In dieser Modalit t ffnet eine Anweisung das Tor und die andere schlief3t es ohne Zwischenstopps Die Funktionen START und PEDONALE Fussg nger blei ben mit der Funksteuerung auf dem ersten bzw dem zweiten Kanal aktivierbar 0 0 Funktion nicht aktiviert 0C 1Funktion aktiviert
38. re de courtoisie se mettent en marche pendant deux secondes avant que la phase d ouverture ou de fermeture ne commence DI 0 fonction non habilit e pll fonction habilit e eS serrure ventouse en activant cette fonction au d but de la man uvre d ouverture une serrure lectrique 12V est command e apr s un temps d acti vation r gl par le param tre t Ser um fonction non habilit e la sortie est active seulement pendant le temps ser SV zl fonction habilit e la sortie reste active et se d sactive seulement pour le temps t Ser eal coup de b lier en ouverture avant de commencer la man uvre d ouvertu re le moteur 1 pousse le vantail en fermeture pendant deux secondes en permet tant la serrure lectrique de s loigner de la but e La serrure se met alors en fonction et la manoeuvre se poursuit r guli rement en ouverture ar 0 fonction non habilit e ar fonction habilit e er amp conomie d nergie maintient les photocellules teintes quand l installation n est pas en marche permettant ainsi des conomies d nergie Les photocellules restent ainsi actives seulement durant le mouvement des vantaux re 0 funzione non abilitata re 1funzione abilitata Raccorder l alimentation 24V aussi bien de l metteur que du r cepteur la sortie du clignotant elm un moteur fonctionnement de l installation avec le moteur 1 seulement In 0 fonction non habilit e Inz1fonction
39. serratura a ventosa attivando questa funzione all inizio della manovra di apertura viene comandata un elettroserratura a 12V dopo un tempo di attivazio ne regolato dal parametro t 5 er v 0 funzione non abilitata l uscita si attiva solo per il tempo t ser da funzione abilitata l uscita rimane attiva e si disattiva solo per il tempo ser eal colpo di ariete apertura prima di iniziare la manovra di apertura il motore 1 spinge l anta in chiusura per due secondi permettendo all elettroserra tura di allontanarsi dal fermo A questo punto la serratura si attiva e la manovra prosegue regolarmente in apertura ar 0 funzione non abilitata af funzione abilitata er risparmio energetico mantiene le fotocellule spente mentre l impianto non attivo consentendo risparmi energetici Le fotocellule cos rimangono attive solo durante il movimento delle ante e durante il t t C re 0 funzione non abilitata ez funzione abilitata Collegare l alimentazione 24V sia del trasmettitore che del ricevitore delle fotocellule all uscita del lampeggiante elm un motore funzionamento dell impianto solo con il motore 1 0 funzione non abilitata Im 1 funzione abilitata een funzionamento encoder permette il funzionamento del sistema anche in caso di guasto dell encoder il portone si blocca poco dopo la sua partenza e sul display viene visualizzata la scritta ENC1o ENC2 en 0 encoder non abilitato en 1 enc
40. tambi n por una pareja de fusibles de 5A Un interruptor diferencial es aconsejado pero no indispensable si ya presente a inicio del establecimiento Alimentar el automatismo a trav s de un cable de 3x1 5mm fase neutro tierra Si la distancia entre la central y la conexi n al establecimiento de tierra sobrepasa los 30m es necesario prever un dispersor de tierra en proximidad de la central Las uniones de cables tienen que ser efectuadas a central apagada Las entradas de los contactos de tipo N C normalmente cerrado si no vienen utilizados van colocados a puente con un tornillo comun 24V Si por la misma entrada hay m s contactos N C stos van colocados en serie entre ellos ejemplo ph1 y ph2 en el esquema Las entradas de los contactos de tipo N O normalmente abierto si no vienen uti lizados hay que dejarlos libres Si por la misma entrada hay m s contactos N O stos van colocados en paralelo entre ellos ejemplo stl y 542 en el esquema 8 Procedura operativa a la primera iniciaci n Efectuar las uniones de cables el ctricos solicita dos por el establecimiento y controlarlos a esque da apagada Li 1 display OLT eAceptarse que los arrestos mec nicos sean insta lados correctamente y el cable de los dos motores Of con los respectivos encoder haya sido efectuado D LED presencia O E red eDesb
41. Phase weniger Kraft und die Einstellung dieses Parameters kann den Sicherheitsgrad der Anlage be einflussen Kontrollieren Sie nach Beendigung der Einstellung dieser Parameter die Anschlagskr fte des Tors esbat Anschlagsraum Es handelt sich hierbei um den in Zentimetern angege benen Raum vor dem Anschlag in der Offnung oder Schliessung bei dem die Zentrale die Hindernisse als Endanschlag auslegt und stehen bleibt Der von Sta gnoli eingegebene Standardraum ist 5 cm und kann von 1 bis 10 cm eingestellt werden ACHTUNG Die Einstellung dieses Parameters kann den Sicherheitsgrad der An lage beeinflussen Die Einstellung ist unter Beachtung der Sicherheitsh he durch zuf hren sodass dieser Parameter so niedrig wie m glich und die Anlage sicher gehalten wird ev rl Bremsgeschwindigkeit Dies sind die geschwindigkeitsbezogenen Werte mit denen die Motoren in der Bremsphase arbeiten Der von Stagnoli eingestellte Standardwert ist 3 und kann von 1 bis 4 eingestellt werden wobei der niedrigste Wert eine geringe Geschwindigkeit angibt und 4 eine Geschwindigkeit bedeutet die etwa der H lfte der Betriebsgeschwindigkeit der Motoren entspricht ef Quetschsicherheitskraft Motor 1 in der ffnung Es handelt sich hierbei um die Quetschsicherheitskraft des ersten Schwingfl gels des Tors die mit Bezug auf die Maximalkraft die dieses abgeben kann in Prozenten angegeben wird Der von Stagnoli eingegebene Standardwert ist 50 und kann v
42. R En ste momento los motores cierran el port n lo abren de nuevo totalmente y repiten sta operaci n otra vez indicando sobre el display de la central el consumo m ximo de los motores Luego plantear los valores de las regulaciones f m a y de manera que sean superiores los valores notados si fmk fm2a fM2C son bajos de valor indican una mayor sensibilidad anti aplastamiento En el caso en que el consumo resulte particularmente elevado verificar que no hayan puntos en que la cancela encuentre una fricci n mayor Para hacerlo ser sene monitorar los valores relativos a la corriente istant nea absorbida por los motores durante su corrida y presentados en la segunda pantalla principal del display Si la operaci n vendr concluida de manera correcta See visualiza do el mensaje K En caso contrario ERR ATENCION durante las maniobra de conocimiento la central ignora los mandos de START y PARA PEATONES y trabaja con los parametros de fuerza planteados Tambi n si permanen activas las seguridades asegurarse que no hayan objetos o personas sobre la traiectoria de trabajo del cerramiento Leyes c digos Es posible verificar si un c digo haya sido memorizado Posicionandose sobre la escrita leggi codice leyes na ulsando el bot n ENTER sobre el di splay vendr visualizado el mensaje R MI PULSA Pulsando ahora el bot n del transmitidor que se desea verificar vendran visu
43. RR will appear GB 8 eerase memory transmitters to cancel all the recorded transmitters enter the menu delet e then go to the wording erase memory transmtters on the display and press ENTER The message PRG will appear it flashes until the decision to cancel all the recorded codes is confirmed by pressing ENTER or the operation is cancelled by keeping the same key pressed E longer N B To cancel the memory of the receiver it is neccessary to confirm twice the cancellation erase memory transmitters and PRG Language The display is available in two languages talano and engish To select the chosen language go to the menu language and press ENTER Go to talano or english and confirm by pressing ENTER Learning This operation allows the automation to automatically establish the start and end of a stroke identifying the respective mechanical strokes Before proceeding with this operation ensure that the gate has been installed correctly and firmly and that the en function of the control board has been activated Stagnoli usi the control board with this function already activated When the wording Set Up appears on the display press ENTER At this point the motors will close the gate They will open it completely again and will repeat this operation once more with the control board display showing maximum use of the motors Then set the regulation values fmla and fmlc so that they exceed the de
44. START fa fa elCh memorizzazione del tasto radiocomando sul secondo canale impul so PEDONALE ol fro sis ol LIS gt Per accedere men per ese uire un operazione premere en tasto ENTER E rilasciando lo velocemente Prolungando 55 la pressione sullo stesso tasto sar possibile tornare al menu OG superiore o annullare l opera zione richiesta funzione ESC Per navigare nei menu usare i tasti freccia su e freccia gi ATTENZIONE Per lo schema della navigazione del menu in inglese vedere le istruzioni nelle altre lingue JOLT funzione ENTER ATTENZIONE Durante la TOL pressione semplice navigazione nei men la centrale ignora i comandi JOLER funzione ESC di START pressione di due secondi F gt 00 00 potenza istantanea assorbita mo tore 1 e dal motore 2 apprendimento leggi codice eapprendiment 0 apprendimento della corsa leggi codice identificazione e riconoscimento trasmettitori reset parametri cancela tutta memoria rado et C tempo di chiusura automatica a apertura pedonale eS 144 tempo di ritardo in apertura del motore 2 e5f C tempo di ritardo in chiusura del motore 1 ef d corsa rallentata in apertura er corsa rallentata in chiusura es hal spazio di battuta ev rl velocit di rallentamento ef mh forza ant
45. a et inversi n total activando sta funci n los motores si encuentran un obst cu lo en fase de abertura invierten el movimiento y cierran totalmente la cancela En fase de conclusi n si encuentran un obst culo invierten el movimiento y se abren totalmente Si la funci n no est activada en fase de abertura los motores se detienen en el caso encuentren obst culos mientras en fase de conclusi n invierten el movimiento de 30cm antes de detenerse t 0 funci n no habilitada t funci n habilitada e dos bordes de seguridad Funcionamiento con dos bordes de seguridad 8k2 unidas en paralelo 2b 0 funci n no habilitada 2b 1 funci n habilitada ecf funcionamiento de recibidora integrada a c digo fijo f 0 la recibidora funciona con los c digos rolling code cf 1 la recibidora funciona con los c digos fijos El funcionamiento a c digo fijo o rolling code de la recibidora viene visualizado tambi n en la pantallla inicial del display donde r 00 indica el funcionamiento a rolling code y f 00 a c digo fijo El recibidor puede memorizar c digos rolling code de tipo HCS300 STAGNOLI con miliardos de combinaciones o c digos fios de tipo HT53200 a 13 bit o la parte fija de un c digo rolling code 28 bit SN 3 alarma Alarma que se ala la cancela que permane abierta Esta funci n activa la salida SCA despu s que han pasado 20 segundos desde la conclusi n del tiempo regulado de t t 8 y la cancel
46. a della modalit pedonale valore impostato di de fault da Stagnoli 70 ed regolabile da 30 a 150 In caso di en il comando di apertura PEDONALE fa aprire totalmente l anta comandata dal motore 1 esfaa tempo di ritardo in apertura del motore 2 In fase di apertura il secondo motore ritarda la sua partenza Il tempo impostato di default da Stagnoli 1 ed regolabile da O a 10 secondi esfac tempo di ritardo in chiusura del motore 1 In fase di chiusura il primo motore ritarda la sua partenza Il tempo impostato di default da Stagnoli 3 ed regolabile da 0 a 10 secondi ATTENZIONE prima di impostare i rallentamenti controllare che il cancello sia bilanciato in maniera corretta Durante questa fase infatti i motori hanno meno forza e l impostazione di questo parametro pu influire sul grado di sicurezza dell impianto stesso Controllare terminata la regolazione di questi parametri le forze ci impatto delle ante er lap corsa rallentata in apertura la centrale rallenta la corsa dei motori nella parte finale di apertura La corsa impostato di default da Stagnoli 20cm ed regolabile da O a 70cm per ante da 1 8 8 er ch corsa rallentata in chiusura la centrale rallenta la corsa dei motori nella parte finale della sua fase di chiusura La corsa impostato di default da Stagnoli 20cm ed regolabile da O a 70cm per ante da 1 8m ATTENZIONE prima di
47. a la codifica esadecimale del tra smettitore Schermate di statistica La centrale di comando dispone di quattro schermate statistiche che vengono visualizzate mantenendo la pressione del tasto ENTER una volta che il display e posizionato sul men principale eprima schermata 210 dove indica il motore Hermes a 24V e 0 versione del software eseconda e terza schermata 0000 0000 indicano il numero delle manovre com plete effettuate equarta schermata indica la corsa in memoria Schermate di diagnostica La centrale in grado di riconoscere problemi o allarmi che si possono verificare sull impianto per cui pu segnalare sul display principale alcuni messaggi per permettere l individuazione del problema el rf attivazione del comando di START sul primo canale di radiofrequenza el f attivazione del comando di START sul canale pedonale eph0 attivazione del l ingresso delle fotocellule in chiusura sulla morsettiera ephoA attivazione del l ingresso delle fotocellule in chiusura e in apertura sulla morsettiera ebar attivazione della costa di sicurezza es t 0 impulso di stop een Cl intervento del sensore ad encoder sul primo motore 1 2 intervento del sensore ad encoder sul secondo motore 0pe attivazione del comando di apertura con 0C ec attivazione del comando di chiusura con 0C eped attivazione del comando di ingresso pedonale 8 ea
48. a sea todav a abierta al 0 funci n no habilidada 3 1 funci n habilitada ete test Viene efectuado un control diagnostico de integridad de los sensores a encoder y amperometrico antes de cada envio de los motores 6 0 funci n no habilidada te l funci n habilitada Cancela ereset parametr reset parametros para cancelar los parametros de las regu laciones y de las funciones reguladas y plantear de nuevo aquellas de fabrica una vez entrados en el men Cancela cancela llevarse sobre la escrita reset parametri reset parametros del display y pulsar el bot n ENTER Vendr visua lizado el mensaje RESE que se iluminar hasta cuando no ser confirmada la intenci n de plantear de nuevo todos los parametros o de anular la operaci n Los parametros planteados de nuevo de default son tt ca z D aped 70 sfaa sfac 3 rlap 20 rich 20 sbatz5 v rl3 fmb 50 fmiz50 fm2a 50 fm2c 50 tserz2 fend 30 ca ba 0 bp 0 7 0 2p 0 d sv 0 ar 0 re 0 m 0 55 0 ac 0 t 0 20 0 cf 0 al 0 ecancela 1 radiocomando cancela 1 radiomando para cancelar el c digo de un transmitidor una vez entrados en el men cancela cancela llevarse sobre la escrita Cancela 1 radiocomando cancela 1 radiomando del display y pulsar el bot n ENTER Vendr visualizado el mensaje PREMI PULSA Pulsar ahora el bot n del transmitidor que hay que cancelar Si la operaci n vendr concluida de ma nera correcta ve
49. a ve AN de d faut programm e par Stagnoli est 50 et est r glable de 20 99 ef force anti crasement du moteur 1 en fermeture c est la force anti cra sement du premier vantail du portail exprim e en pourcentage par rapport la force maximum qu il peut fournir La valeur de d faut programm e par Stagnoli est 50 et est r glable de 20 99 ef m2a force anti crasement du moteur 2 en ouverture c est la force anti cra sement du second vantail du portail exprim e en pourcentage par rapport la force maximum qu il peut fournir La valeur de d faut programm e par Stagnoli est 50 et est r glable de 20 99 ef force anti crasement du moteur 2 en fermeture c est la force anti cra sement du second vantail du portail exprim e en pourcentage par rapport la force maximum qu il peut fournir La valeur de 3418 programm e par Stagnoli est 50 et est r glable de 20 99 ATTENTION la programmation de ces deux param tres peut influencer le degr de s curit de l installation Stagnoli conseille de programmer ces param tres avec une marge de s curit telle qu ils soient au moins de 10 par rapport au niveau maximum de courant consomm par le moteur respectivement en phase d ouverture et de fermeture Celui ci peut tre lu sur le display durant la course du moteur dans la deuxi me page vid o principale Si fma fm fm2a et ont une valeur basse cela indique une plus grande
50. alimenter la centrale La led de pr sence r seau s allumera alors et le display indiquera I OU Dans le cas contraire s assurer que la centrale soit sous tension et v rifier les entr es mises en fonction voir la descrip tion des diagnostics du display Mettre un apr s l autre les dispositifs de s curit en marche et v rifier que l inscription de diagnostic correspondante apparaisse sur le display Par exemple mre intervenir la photocellule et v rifier que le message pho apparaisse sur le isplay Enter le menu et s lectionner la rubrique apprendimento apprentissage les deux premi res manoeuvres servent pour identifier le d but et la fin de la course du moteur les deux suivantes servent relever le pic d absorption du moteur durant la fermeture et l ouverture du portail Dans cette phase contr ler les valeurs visualis es sur le display A la fin de la phase d apprentissage 0k sera affich sur le dupin si la pe grammation est correcte ou si des erreurs sont intervenues sera affich Pour sortir de la programmation appuyer sur la touche de s lection ENTER Programmer correctement les niveaux de force anti crasement en ouverture et en fermeture qui doivent tre sup rieurs aux valeurs maxima visualis es durant l apprentissage ATTENTION ce r glage peut influencer le degr de s curit de l automation Durant les manoeuvres d apprentissage la centrale ignore les commandes de START
51. alizadas una serie de pantallas descriptivas del c digo eprimera pantalla 5 r 01o f 01 El primer car cter indica el productor del radiomando donde 5 indica Stagnoli y un productor generico El segundo car cter indica la tipologia de c digo donde I indica rolling code y f c digo fijo los ultimos dos car cteres indican el c dico del bot n pulsado segunda pantalla 00 donde indica la palabra posici n y la cifra sucesi va progresiva de O a 75 indica la posici n ocupada por el transmitidor en me moria En el caso en que el transmitidor no sea presente en memoria aparecer sobre el display cuarta pantalla vendr visualizada la codificaci n exadecimal del transmitidor Pantallas de estadistica La central de mando dispone de cuatro pantallas estad sticas que vienen visua lizadas manteniendo la presi n del bot n ENTER una vez que la pantalla est posicionada sobre el men principal eprimera pantalla ED donde 2 indica el motor Hermes a 24V y Olla versi n del software segunda y tercera pantalla 0000 0000 indican el n mero de las maniobras completas efectuadas ecuarta pantalla indica la corrida en memoria Pantallas de diagnostica La central es en grado de reconocer problemas o alarmas que se puedan verificar sobre el establecimiento para que pueda sefialar sobre el display principal algu nos mensajes para permitir la individuaci n del problema el rf activaci n del
52. and the PEDESTRIAN terminal input becomes CLOSE In this mode one control opens the gate and another closes it without intermediate stops The PEDESTRIAN and START functions can be activated with the radio control on the first and second channels respectively 0c 0 function not enabled 0 1 function enabled CB 8 eit total reversal activating this function if the motors encounter an obstacle in the opening phase they reverse the motion and close the gate completely In the closing phase if they encounter an obstacle the movement is reversed and the gate opens completely If the function has not been activated in the opening phase the motors stop if they encounter obstacles while in the closing phase they reverse motion by 30cm before stopping t 0 function not enabled t 1 function enabled 02h two safety ribs Operates with two safety ribs 8k2 connected in parallel 2 0 function not enabled 2 function enabled ecf operation of the fixed code integrated receiver f receiver works with rolling codes cf 1 receiver works with fixed codes Functioning with receiver fixed codes or rolling codes can also be seen on the initial page of the display where 00 indicates the rolling code functioning and f 00 functioning with fixed code The receiver can memorise rolling codes type HCS300 STAGNOLI with billions of combinations or fixed codes type HT53200 with 13 bits or the
53. ation and reco gnition of transmitters et t C automatic closing time eg A pedestrian opening es delay in opening time of motor 2 esfac delay in closing time of motor 1 er d slowed stroke in opening er slowed stroke in closing es Dat strike space ey rl slowing speed ef mh anti crushing force of motor 1 in opening ef anti crushing force of motor 1 in closing ef M2 anti crushing force of motor 2 in opening d Ma anti crushing force of motor 2 in closing f ef electric lock activation time efend final thrust force on striking e automatic closing 0 a blocks impulses during opening eb blocks impulses during pause et I rapid closing 0 open close operation e l preflashing eS V suction lock eal impact on opening ef energy saving elm operation with one motor encoder operation eS S soft start open close operation elt total reversal after encountering an obstacle 7 two safety ribs ecf operation of the fixed code receiver o l alarm et e diagnostics check before every start edefaut parameter setting of factory parameters eerase 1 transmitter cancels one transmitter eerase memory transmitters cancel all registered transmitters GB Addition of radio controls Before memorising a transmitter make sure that it is compatible with the type of receiver that is integrated the first time the
54. avoir des absorptions basses au repos pour permettre une consommation d ner gie lectrique basse Des professionnels du secteur ont port une attention particuli re pour faciliter la programmation de la centrale gr ce un display en plusieurs langues AVERTISSEMENTS ET CONSIGNES DE SECURITE Le pr sent manuel a t r alis par Stagnoli pour une utilisation sp cifique de la part d un personnel professionnel et qualifi Nous conseillons de lire int gralement le manuel d instructions avant de proc der l installation du produit Durant le c blage la tension doit tre coup e sur l installation Les installations de portails automatiques doivent tre effectu es par un personnel technique qualifi et dans le respect des normes de la loi Bien informer l utilisateur final sur les modalit s d utilisation sur le dan ger r siduel sur la n cessit d entretien et sur la n cessit d un contr le des dispositifs de s curit au moins tous les six mois De AB d k N bi el h e h E 12 13 14 15 16 17 18 19 2O 21 22 23 24v M moire installation Display Touches de programmation Relais directionnel moteur 1 Relais directionnel moteur 2 Mosfet moteur 1 Mosfet moteur 2 Relais clignotant Pont d
55. ben und Pfeil unten zu benut zen A Jo 1 JOL regolazioni funzioni ttca av e no o un gt e gt e ce lt gt rap rich sbat n lt gt 3 E ma mic Ser ACHTUNG F r den englischen Naviga tionsplan der Men s sind die Anweisungen in den anderen Spra chen einzusehen Funktion ENTER ACHTUNG W hrend der einfacher Druck Navigation in den Men s ignoriert die Zentrale die Funktion ESC Befehle START Druck von zwei Sekunden PUNH uBSunp ISU UBUPSO I reset parametri cancela 1 radiocomando cancela tutta memoria radio 8 ell 00 vom Motor 1 und dem Motor 2 genommene Momentanleistung apprendimento leggi codice eapprendiment 0 Lauferlernung leggi codice Identifizierung und Anerkennung der Funksender talano et t Ca automatische Schliesszeit ea Jed Offnung Fussg nger es 144 Verz gerungszeit Offnung Motor 2 e5 f Verz gerungszeit Schliessung Motor 1 er Ji gebremster Weg Offnung erkh gebremster Weg Schliessung es bat Anschlagsraum ey Bremsgeschwindigkeit ef Quetschsicherheitskraft Motor 1 in der ffnung ml Quetschsicherheitskraft Motor 1 in der Schliessung fm2 Quetschsicherheitskraft Moto
56. c activation of the closing command with 0C eped activation of the pedestrian entry command ea activation of the anti crushing sensor on motor 1 ea activation of the anti crushing sensor on motor 2 Technical specifications e Automation feed 230V 50 60Hz ePrimary transformer protection fuse T1 25A 230V Accessory output protection fuse 24V F2 5A eIntegrated receiver 433Mhz maximum capacity 76 radio codes e Operating temperature 20 455 e Maximum rated power of motors 70W 70W eFlasher output maximum power 25W Open gate detector output maximum power SCA 5W Electronic anti crushing device amperometric with encoder 8 F A Q Frequently Asked Questions Why shall I have to choose a rolling code transmitter instead of a fix one The rolling code transmitters are safer as they can t be cloned and have 200 million combinations They change for every transmission On the contrary the fix code tran smitters have 1024 code combinations They don t change for every transmission Can the control board run the operation of the motor with emergency batteries Yes To use emergency batteries use the kit supplied by Stagnoli The station does not recognise the transmitter Why Check that you are using the same type of station and transmitter It is possible to check the type of transmitter used by the station from the main screen and change if ne
57. cessary by setting the parameter C Once the motor gets to the stop it turns back instead of arresting Why One reason that can make the control board loose its parameters is that the motor has been working while unlocked To be sure that the control board has found back its parameters shut off the supply make sure that the motor is locked and then put the supply back to the control board At the first START input the control board will find again its parameters GB ELECTRIC LOCK OPEN GATE y DETECTOR en O 230 pen ANTENNA gi gt O 24 1 A a VE S TX RX RX TX i Pu PHOTOCELLS PHOTOCELLS ir IN CLOSING IN OPENING nu Hh BATTERY CHARGER BOARD WARNING If a battery charger is used the control board is supplied by the C24 charger board linked to a trasnsformator For the details of the connection see the C24 instructions GB MOTOR I 3 O 5 z E J 77 MOTOR 2 9888 COMMON PEDESTRIAN OPENING KL LET ED d SAFETY RIB 1111 ree COMANDS 8 Le E24 de Stagnoli est la centrale de commande tudi e pour les moteurs battants 24V et accessoires correspondants R alis e seulement avec des mat riels de premier choix elle a t projet e pour
58. da pantalla principal fma efm2c bajos de valor indican una mayor sensibilidad anti aplastamiento Verificar a conclusi n de la instalaci n que las fuerzas de empate respeten la norma EN12453 et ser tiempo de activaci n de la electrocerradura es el tiempo expreso en segundos que intercurre entre la conclusi n total de la cancela y la presencia de la electrocerradura El valor planteado de default por Stagnoli es 2 y es regulable de 0 a 7 segundos ATENCION verificar que el enganche de la cerradura proceda sin crear friccio nes y regular el parametro t 5 f de consecuencia efend fuerza final de empuj n en golpe es la fuerza que los motores ejercen en fase de conclusi n una vez que han logrado los golpes de fincorrida Esta viene expresa en porcentaje respeto a la fuerza m xima que los motores mismos pueden ejercitar El valor planteado de default por Stagnoli es 30 y es regulable de 20 a 70 ATENCION regular fend con un valor bajo en el caso en que la estructura de la cancela sea muy ligera La regulaci n de ste parametro puede influir el tiempo y la fuerza con que la cancela trabaja en la fase final de su corrida Funciones conclusi n autom tica conclusi n autom tica de la cancela despu s de su completa abertura 3 0 funci n no habilitada 8 1 funci n habilitada Plantear la regulaci n tt para personalizar el tiempo que tiene que transcurrir entre el final de la
59. e the photocell and check that the message PN0 shows on the display Enter the menu and select the item S t Up The first two manoeuvres help to Ge the start and end of the stroke of the motor The two that follow detect the pea of absorption of the motors when the gate is closing and opening In this phase monitor the values shown on the display At the end of the learning phase the display will show ok if programming was done correctly or if errors occurred To exit the programme press the select key eCorrectly set the levels of anti crushing force in opening and in closing these must be greater than the maximum values viewed during learning WARNING this regulation can influence the degree of safety of an automated evice During learning manoeuvres the control board ignores the START and PEDE STRIAN commands and works with the force parameters that have been set Even if the safeties remain active make sure that there are no objects or people in the pathway of the gate out some test cycles checking the correct operation of the entire system eMeasure the force of impact of the gate according to the specifications of regu lation EN12445 N B If a blackout occours while the automation is working the first START com mand given to the control board with power supply back will close the gate until the board finds the stops Let the motor finish its run before giving other comman s 8
60. elf Once these parameters have been regulated check the force of impact of the gate leaves esbat striking space this is the space in centimetres before the strike when opening or closing when the control board interprets the obstacles as a limit stop and stops The default space set by Stagnoli is 5cm and can be regulated from 1 to 1Ocm WARNING The way this parameter is set can influence the level of safety of the system itself Installation must be carried out in compliance with the safety mea surements in order to keep this parameter as low as possible and to ensure the safety of the system ev slowing speed these are values that concern the speed with which the motors operate in the slowing phase The default value set by Stagnoli is 3 and it can be regulated from 1 to 4 where the lowest value indicates low speed and 4 indicates a speed of approximately half the motor operating speed ef mia anti crushing force of motor 1 in opening this is the anti crushing force of the first leaf of the gate stated in percentage compared with the maximum force that the same can generate The default value set by Stagnoli is 50 and it can be regulated from 20 to 99 ef mi anti crushing force of motor 1 in closing This is the anti crushing force of the first leaf of the gate stated in percentage compared with the maximum force that the same can generate The default value set by Stagnoli is 50 and it can be regulated from 20 to 99
61. ertura e in chiusura che devono essere superiori ai valori massimi visualizzati durante l ap prendimento AITENZIONE questa regolazione pu influire sul grado di sicurezza dell auto mazione Durante le manovre di apprendimento la centrale ignora i comandi di START e PEDONALE e lavora con i parametri di forza impostati Anche se rimangono attive le sicurezze assicurarsi che non vi siano oggetti o persone sulla traiettoria di lavoro del cancello eEffettuare alcuni cicli di prova verificando il corretto funzionamento di tutto l im pianto eEffettuare le misure della forza di impatto del cancello secondo quanto specifi cato dalle norme EN12445 N B Nel caso vi sia un interruzione di alimentazione durante la manovra di aper tura o chiusura dell automazione al ritorno dell alimentazione il primo comando di START comander la chiusura totale per cercare le battute di arresto Lasciare quindi che sia completata la manovra di chiusura sino all arresto e poi immettere nuovi comandi 8 er indicatore ricevitore rang code e il tratto superiore indica il fu nzionamento dell encoder lt del primo motore mentre quello inferiore del secondo e00 trasmettitori registrati gt agg radioc regolazioni funzioni AN AN Es 9400 radi0C memoriz stac zazione radiocomandi far a ekh memorizzazione del tasto radiocomando sul primo canale impulso rich di
62. ertura para peatones es la longitud de la corrida expresada en cen timetros de la abertura parcial o bien de la modalidad para peatones El valor planteado de default por Stagnoli es 70 y es regulable de 30 hasta 150 En caso de en 0 el mando de abertura PARA PEATONES hace abrir totalmente la parte mandada por el motor 1 122 tiempo de retraso en abertura del motor 2 En fase de abertura el segun do motor retrasa su salida El tiempo planteado de default por Stagnoli es 1 y es regulable de O hasta 10 segundos esfa tiempo de retraso en conclusi n del motor 1 IEn fase de conclusi n el primer motor retrasa de su salida El tiempo planteado de default por Stagnoli es 3 y es regulable de O hasta 10 segundos ATENCION antes de plantear las reducciones controlar que la cancela sea ba lanceada de manera correcta Durante sta fase en efecto los motores tienen menos fuerza y la impostaci n de ste parametro puede influir sobre el grado de seguridad del establecimiento mismo Controlar terminada la regulaci n de stos parametros las fuerzas del establecimiento de las puertas er lap corrida moderada en abertura la central modera la corrida de los moto res en la parte final de abertura La corrida planteada de default por Stagnoli es 20cm y es regulable de O a 70cm para puertas de 1 8m F gt er corrida moderada en conclusi n lla central modera la corrida de los mo tores en la parte final de su fase de
63. et Totalumkehr Mit der Aktivierung dieser Funktion kehren die Motoren wenn sie in der Offnungsphase auf ein Hindernis treffen die Bewegung um und schlie en das Tor vollst ndig In der Schliessphase kehren sie wenn sie auf ein Hindernis treffen die Bewegung um und ffnen das Tor ganz Wenn die Funktion nicht aktiviert ist bleiben die Motoren falls sie auf ein Hindernis treffen stehen w hrend sie in der SchlieBphase die Bewegung etwa 50 cm vor dem Stehenblei ben umkehren 0 Funktion nicht aktiviert it Funktion aktiviert 7 zwei Sicherheitsflanken Betrieb mit zwei parallel geschalteten Sicherhei tsflanken 8k2 2b 0 Funktion nicht aktiviert 2b 1Funktion aktiviert ecf Betrieb des integrierten Festcode Empfangers f Der Empf nger funktio niert mit den Rolling Code Codes cf 1 Der Empf nger funktioniert mit Festcodes Der Betrieb mit einem Festcode oder Rolling Code des Empf ngers wird auch auf der ersten Bildschirmanzeige des Displays angezeigt wo l 00 den Betrieb mit Rolling Code und f 00 mit Festcode angibt Der Empf nger kann Codes des Rolling Code vom Typ HCS300 STAGNOLI mit Milliarden von Kombinationen speichern oder Festcodes vom Typ HT53200 mit 13 Bit oder den festen Teil eines Rolling Code Codes 28 Bit SN ei Alarm Dieser Alarm gibt an dass das Tor offen geblieben ist Diese Funktion F aktiviert den Ausgang SCA nachdem 20 Sekunden ab dem Ablaufen der mit ttCa eingeste
64. eventualmen te cambiarlo impostando il parametro Cf Arrivata alle battute di arresto l automazione inverte il moto invece di fermarsi Per ch Una delle cause per cui la centrale possa aver perso i suoi riferimenti il fatto che l automazione sia stata attivata mentre era sbloccata Per fare in modo che la centrale ritrovi le sue coordinate sar sufficiente togliere la tensione assicurarsi che l automa zione sia bloccata e poi ridare la tensione alla centrale Al primo impulso di start la centrale ritrover i suoi riferimenti ELETTROSERRATURA SPIA CANCELLO v 5 1 APERTO e 65 3NnWOO teas SI N ANTENNA 0 TRASFORMATORE TX FOTOCELLULE FOTOCELLULE IN CHIUSURA IN APERTURA o nu BATTERIE Fa A CENTRALE CARICABATTERIE ATTENZIONE Nel caso venga utilizzato un caricabatterie la centrale di comando viene alimentata dalla centrale caricabatterie C24 collegata a un trasformatore Per le specifiche del collegamento vedere le relative istruzioni MOTORE 1 TRASFORMATORE ALIMENTAZIONE _ ma 2 2 r 24 Vat DER det wen i SE l2 PIE 5 yum pace al 48 9 C L D Ai festa sas s 9 EEE COMUNE tH 2 APERTURA PEDONALE a PRE ii 2 5 8 Gi TT E 2 en
65. gio dei due motori con Tor rispettivi encoder sia stato effettuato JOL 2 a m gt eSbloccare il cancello e controllarne il movimento LED di pre OTE le ante non devono trovare ostacoli durante il loro senza reter _ percorso La corsa delle ante non deve presentare punti duri durante il movimento che deve essere fluido Bloccare il cancello e alimentare la centrale A questo punto si accender il led di presenza rete e il display indicher r 00 of 00 In caso contrario accertarsi che la centrale sia in tensione e verificare gli ingressi attivati vedere la descrizio ne delle diagnostiche del display uno alla volta i dispositivi di sicurezza e verificare che a display com paia la scritta di diagnostica relativa Ad esempio far intervenire la fotocellula e verificare che compaia a display il messaggio pho Entrare nel men e selezionare la voce 111 le prime due manovre servono per identificare l inizio e la fine della corsa dei motori Le due seguenti servono a rilevare il picco di assorbimento dei motori durante la chiusura e l aper tura del cancello In questa fase monitorare i valori visualizzati a display e Al termine della fase di apprendimento sul display sar visualizzato 0k nel caso di corretta programmazione f nel caso vi siano stati degli errori Per uscire alla programmazione premere il tasto di selezione elmpostare correttamente i livelli di forza antischiacciamento in ap
66. gnoli hat diese Funktion bei der ae der Zentrale bereits aktiviert Nach der Anzeige des Punktes apprendimento Lernvorgang auf dem Display ist die Taste ENTER zu dr cken Jetzt werden die Motoren das Tor schliessen wieder vollst ndig ffnen und diesen Vorgang ein weiteres Mal wiederholen wobei auf dem Display der Zentrale der maximale Verbrauch der Motoren angegeben wird Dann sind die Werte der Einstellungen fma und einzustellen sodass sie h her als die aufgenommenen Werte sind wenn f ma fmk fm2a und niedrige Wer te haben zeigen sie eine gr ere Quetschsicherungsempfindlichkeit an Falls der Verbrauch besonders hoch sein sollte ist zu pr fen dass keine Stellen vorhanden sind an denen das Tor auf eine h here Reibung trifft Dazu ist es ausreichend die Werte zu berwachen die sich auf den von den Motoren wah rend ihres Laufs aufgenommenen Augenblicksstrom beziehen und auf der zweiten Hauptbildschirmanzeige des Displays gezeigt werden Wird der Vorgang korrekt zu Ende gef hrt erscheint die Meldung Andernfalls ERR ACHTUNG W hrend der Lernbewegungen ignoriert die Zentrale die Anweisun gen START und PEDONALE Fussg nger und arbeitet mit den ausgew hlten Kraf tparametern Obgleich die Sicherheitsvorrichtungen aktiv bleiben ist sicherzustel len dass keine Gegenst nde oder Personen auf dem Arbeitsweg des Tors sind Code Lesen Es kann gepr ft werden ob ein Code gespeichert worden ist Durch den Zu
67. griff auf die Schrift leggi codice Code lesen und durch den Druck der Taste ENTER wird auf dem Display die Meldung PREMI angezeigt Wenn jetzt die Taste des zu pr fenden Senders gedr ckt wird erscheint eine Reihe von Bildschirmanzeigen die den Code beschreiben eerste Bildschirmanzeige 5 r 01 01 Der erste Buchstabe gibt den Hersteller der Funksteuerung an wobei 9 f r Stagno li steht und f r einen allgemeinen Hersteller Der zweite Buchstabe gibt die Typologie des Codes an wobei I f r Rolling Code und f f r Festcode steht Die letzten beiden Buchstaben geben den Code der gedr ckten Taste an ezweite Bildschirmanzeige wo P f r das Wort Position steht und die folgende Zahl progressiv von O bis 75 die Position anzeigt die der Sender im Speicher belegt Sollte der Sender nicht im Speicher vorhanden sein erscheint auf dem Display edritte und vierte Bildschirmanzeige es wird die hexadezimale Codierung des Senders angezeigt Statistische Bildschirmanzeigen Die Steuerzentrale verf gt ber vier statistische Bildschirmanzeigen die erschei nen wenn die Taste ENTER nach der Platzierung des Displays auf dem Haupt men gedr ckt gehalten wird e erste Bildschirmanzeige ED wo den Hermes Motor von 24V und 01 die Software Version anzeigen zweite und dritte Bildschirmanzeige 0000 0000 zeigt die Anzahl der durchge 8 f hrten kompletten Bewegungen an
68. habilit e een fonctionnement encodeur permet le fonctionnement du syst me m me en cas de panne de l encodeur le portail se bloque peu apr s son desan et l inscrip tion ENCI ou ENC2 est affich e sur le display en 0 encodeur non habilit en lencodeur habilit ATTENTION le fonctionnement du syst me sans l encodeur doit tre consid r comme gestion d urgence Dans cette modalit tout obstacle rencontr par les moteurs commande l inversion du mouvement d environ 20 cm e55 soft start permet aux moteurs d effectuer un d part doux et vitesse r du ite pour diminuer la sollicitation des parties m caniques de l installation En ac tivant cette fonction les moteurs fournissent une force inf rieure lors de la phase 8 de d part 55 0 fonction non habilit e 55 l fonction habilit e 0 fonctionnement open close l entr e sur la plaque bornes de START de vient OPEN et l entr e sur la plaque bornes de PIETON devient CLOSE Dans cette modalit une commande ouvre le portail et l autre le ferme sans arr ts interm diaires Les fonctions START et PIETON peuvent tre activ es avec la radio commande respectivement sur le premier et le second canal 0 0 fonction non habilit e 0C 1 fonction habilit e et inversion totale en activant cette fonction les moteurs si ils rencontrent un obstacle aussi bien en phase d ouverture qu en phase de fermeture
69. i aplastamiento de la primera puerta de la cancela expresa en porcentaje respeto a la fuerza m xima que el mismo puede erogar El valor planteado de default por Stagnoli es 50 y es regulable de 20 a 99 ef fuerza anti aplastamiento del motor 1 en conclusi n es la fuerza anti aplastamiento de la primera puerta de la cancela expresa en porcentaje respeto a la fuerza m xima que el mismo puede erogar El valor planteado de default por Stagnoli es 50 y es regulable de 20 a 99 efm2a fuerza anti aplastamiento del motor 2 en abertura es la fuerza anti aplastamiento de la segunda puerta de la cancela expresa en porcentaje respeto a la fuerza m xima que el mismo puede erogar El valor planteado de default por Stagnoli es 50 y es regulable de 20 a 99 efm2c fuerza anti aplastamiento del motor 2 en conclusi n es la fuerza anti aplastamiento de la segunda puerta de la cancela expresa en porcentaje respeto a la fuerza m xima que el mismo puede erogar El d planteado de default por Stagnoli es 50 y es regulable de 20 a 99 ATENCION la impostaci n de estos dos parametros puede influir sobre el gra do de seguridad de la instalaci n misma Stagnoli aconseja de plantear stos parametros con un margen de seguridad tal que resulten al menos 10 respeto al m ximo de la corriente consumida por los motores respetivamente en fase de abertura y de conclusi n Esta se puede leer durante la corrida de los motores sobre el display en la segun
70. i schiacciamento del motore 1 in apertura ef mr forza anti schiacciamento motore 1 in chiusura fm2a forza anti schiacciamento del motore 2 in apertura d Ma C forza anti schiacciamento del motore 2 in chiusura Uazo et 5 61 tempo di attivazione dell elettroserratura efend forza finale di spinta in battuta eC chiusura automatica blocca impulsi durante l apertura p blocca impulsi durante la pausa chiusura rapida funzionamento apri chiudi 0 gt prelampeggio eS V serratura a ventosa ear colpo di ariete in apertura el risparmio energetico e n funzionamento con un motore een funzionamento encoder e5 5 soft start funzionamento open close elt inversione totale dopo l incontro di un ostacolo e h due coste di sicurezza ecf funzionamento della ricevente a codice fisso ei l allarme et controllo diagnostico prima dl ogni partenza ereset parametri impostazione dei parametri di fabbrica ecancela 1 radocomando cancellazione di un trasmettitore cancela tutta memoria radi cancellazione di tutti i trasmettitori registrati NI EECH IECH Aggiunta radiocomandi ePrima di memorizzare un trasmettitore assicurarsi che sia compatibile con la tipologia di ricevitore integrato nella prima visualizzazione del display apparir se si tratta di un ricevitore in modalit rolling code of se si tratta tiva ricevitore in modalit codice
71. ichiesto di confermare due volte la volont di effettuare la cancellazione stessa cancela tutta memoria radio e PRG Lingua Il display pu visualizzare i messaggi in due lingue talano e englsh Per scegliere la lingua di funzionamento portarsi sul men lingua e premere EN TER Portarsi a questo punto sulla lingua talano english e confermare schiac ciando nuovamente ENTER Apprendimento Questa operazione permette all automazione di stabilire automaticamente l ini zio e la fine della corsa individuando le rispettive battute meccaniche Prima di rocedere con questa operazione assicurarsi che il cancello sia fissato e che a funzione N della centrale sia attiva Stagnoli fornisce la centrale con questa funzione gi attivata Visualizzata la voce apprendimento sul display premere il tasto ENTER A questo punto i motori chiuderanno il cancello lo riapriranno totalmente e ripeteranno questa operazione un altra volta indicando sul display della centrale massimo dei motori Impostare poi i valori delle regolazioni fm e fmk modo che siano superiori ai valori rilevati se fma fmk fm2a e fM2 C sono bassi di valo re indicano una maggiore sensibilit anti schiacciamento Nel caso in cui il consumo risulti particolarmente elevato verificare che non vi sia no punti in cui il cancello incontra un attrito maggiore Per farlo sar sufficiente monitorare i valori relativi alla corrente istantanea assorbita dai motori durante la
72. iodes Module r cepteur PTC 3A pour serrure lectrique 12V Mosfet serrure lectrique Borne de sortie voyant portail ouvert SCA accessoires serrure lectrique Relais voyant portail ouvert PTC 0 1A encodeur Borne antenne radio Jump cordon r sistif Borne d entr e cordon Connecteur entr es commandes Connecteur encodeur moteur Connecteur moteurs clignotant Borne d alimentation de la centrale 24V Fusible 2 5A rapide serrure lectrique voyant portail ouvert SCA LIGNE 5 i ATTENTION 2 lencodeur la centrale y en respectant les couleurs 5358 de c ble indiqu es 5252 E gt gt E na LI 94 dav Ein lo la 24V EEE i mot1 mot2 IS 0 230 RS common Nm RANSFORMATEUR 5 24 0 pi ton commun start stop photocellules en ou photocellules verture et en fermeture en fermeture La ligne d alimentation 230V LN vers l automatisme doit tre prot g e par un interrupteur magn tom trique ou bien par un couple de fusible de 5A Un interrupteur diff rentiel est conseill mais non indispensable si d j pr sent en amont de l installa tion Alimenterl automatisme parl interm diaired unc ble de 3x1 5mm phase neutre terre Si la distance entre la centrale et la connexion l installation de terre d passe
73. kt zu Ende gef hrt erscheint die Meldung OK Andernfalls ERR ecancela tutta memora radio gesamten Funkspeicher l schen Um alle re gistrierten Sender zu l schen muss nach dem Zugriff auf das Men cancela L schen auf die Anzeige cancela tutta memoria radio gesamten Funkspeicher l schen des Displays zugegriffen und die Taste ENTER gedr ckt werden Es wird die Meldung Me die solange blinkt bis das Vorhaben alle registrier ten Codes zu l schen mit der Taste ENTER best tigt oder der Vorgang durch den verl ngerten Druck derselben Taste annulliert wird WICHTIG Um die L schung aller im Speicher vorhandenen Codes zu Ende zu f hren muss man zweimal die Annullierung best tigen alles im Cancela tutta memoria radio und PRG Sprache n Das Display kann die Meldungen in zwei Sprachen anzeigen f alano italienisch und engish englisch F r die AG der Betriebssprache muss auf das Men lingua Sprache zuge griffen und ENTER gedr ckt werden Jetzt muss auf die Sprache ta lano nisch oder engish englisch zugegriffen und mit dem erneuten Druck der Taste ENTER best tigt werden Lernvorgang Dieser Vorgang erm glicht es der Automatisierung selbstst ndig den Beginn und das Ende des Wegs festzusetzen indem die jeweiligen mechanischen Anschl ge individualisiert werden Bevor mit diesem Vorgang fortgefahren wird ist zu pr fen dass das Tor befestigt und die Funktion der Zentrale aktiv ist Sta
74. lastamiento en abertura y en conclusi n que tienen que ser superiores a los valores m ximos visualizados durante el conocimiento ATENCION sta regulaci n puede influir sobre el grado de seguridad de la av tomaci n Durante las maniobras de conocimiento la central ignora los mandos de START y PARA PEATONES y trabaja con los parametros de fuerza planteados Tambi n si quedan activas las seguridades asegurarse que no haya presencia de objetos o personas sobre trayectoria de trabajo de la cancela Efectuar algunos ciclos de prueba verificando el correcto funcionamiento de todo el establecimiento eEfectuar las medidas de la fuerza de empate de la cancela seg n cuanto espe cificado por las normas EN12445 N B En caso de que haya una interrupci n de alimentaci n durante una opera ci n de abertura o cierre de la automaci n al volver de la alimentaci n misma el primero mando de START empiezar el cierre total para buscar el paro de la automaci n Dejar que se concluya la operaci n de cierre hasta el paro y de spu s insertar los nuevos mandos 8 er indicador recibidor rolling code el trato superior indica el funcionamiento del encoder del primer motor mientras el inferior del segundo transmetidores registrados r00 jE gt AN 200 1200 memoriza ci n radiodirigidos elh memorizaci n del bot n radiodirigido sobre el primer canal impulso
75. le premier caract re indique le producteur de la radiocommande 5 indique Stagnoli et un producteur g n rique Le deuxi me caract re indique la typologie de code o r indique rolling code et f code fixe les deux derniers caract res indiquent le code de la touche enfonc e epremi re page cran 5 0lo f 01 le premier caract re indique le producteur de la radiocommande ov 5 indique Stagnoli et un producteur g n rique Le deuxi me caract re indique la typologie de code o I indique rolling code et f code fixe les deux derniers caract res indiquent le code de la touche enfonc e edeuxi me page cran P 00 o indique le mot position et le nombre suivant progressif de 0 75 indique la position occup e par l metteur en m moire Si l metteur n est pas pr sent en m moire s affichera sur le display etroisi me et quatri me pages crans la codification hexad cimale de l metteur sera affich e Pages crans de statistique La centrale de commande dispose de quatre pages crans de statistique qui sont affich es en maintenant la pression sur la touche ENTER une fois que le display est positionn sur le menu principal epremi re page cran ED ov E indique le moteur Hermes 24V et 0 ver sion du logiciel edeuxi me et troisi me pages crans 0000 0000 indiquent le nombre de manceu vres compl tes effectu es equatri me page cran indique la course en m moire
76. lla pericolosit residua sulla necessit della manutenzione e sulla necessi De t di un controllo dei dispositivi di sicurezza almeno ogni sei mesi Bee 12 13 14 15 16 17 18 19 2O 21 22 23 24v Memoria impianto Display Tasti di impostazione Rel direzionale motore 1 Rel direzionale motore 2 Mosfet motore 1 Mosfet motore 2 Rel lampeggiante Ponte diodi Modulo ricevitore PTC 3A per elettroserratura da 12V Mosfet elettroserratura Morsetto uscite spia cancello aperto SCA accessori elettroserratura Rel spia cancello aperto PTC 0 1A encoder Morsetto antenna radio Jump costa resistiva Morsetto ingresso costa Connettore ingressi comandi Connettore encoder motore Connettore motori lampeggiante Morsetto alimentazione centrale a 24V Fusibile 2 5A rapido lettroserrat ra spiacancelloaperto SCA 5 N 2 o 8 E LINEA we ATTENZIONE Collegare 25 98 encoder alla centrale ri 55 spettando colori dei cavi Efo 5555 indicati yo E 2525 E SuSE C E s2 4 pa 2 E 1 LI av gv IR m 24V 45 1 mot2 25W TRASFORMATORE lampeggiante
77. llten Zeit verstrichen sind und das Tor noch immer ge ffnet ist al 0 Funktion nicht aktiviert al 1 Funktion aktiviert ete Test Vor jedem Start der Motoren wird eine Diagnosekontrolle f r die Un versehrtheit der Strom und Encoder Sensoren durchgef hrt te 0 Funktion nicht aktiviert t ez1Funktion aktiviert L schen ereset parametri L schen der Einstellungsparameter und der eingestellten Funktionen und f r die Wiederherstellung derjenigen des Herstellers muss nach dem Zugriff auf das Men cancela L schen auf die Anzeige reset parametri des Displays zugegriffen und die Taste ENTER gedr ckt Weiden Es wird die Mel dung R SE angezeigt die solange blinkt bis das Vorhaben alle Parameter wie der herzustellen oder den Vorgang zu annullieren best tigt wird Die eingestellten Standardparameter sind t t c de d sfaazl sfac 3 rlapz20 rkhz20 sbat 5 v fma 50 fmkz5 fma 50 fm2c 50 tser 2 fend 30 caz ba 0 bp 0 cr 0 2p 0 pl 0 sv 0 ar 0 re 0 m 0 en 55 0 ac 0 t 0 20 0 cf 0 2 0 te 0 ecancela 1 radiocomando 1 Funksteuerung l schen Um den Code eines Sen ders zu l schen muss nach dem Zugriff auf das Men Cancela L schen auf die Anzeige cancela 1 radiocomando 1 Funksteuerung l schen des Displays zugegriffen und die Taste ENTER gedr ckt werden Es wird die Meldun PREVI Dr cken angezeigt Dr cken Sie an dieser Stelle die Taste des zu Senders Wird der Vorgang korre
78. loquear la cancela y controlar su movimiento las puertas no tienen que ser obstaculadas duran te su percurso La corrida de las puertas no tiene que presentar puntos duros durante el movimiento que tiene que ser fluido Bloquear la cancela y alimentar la central En ese preciso momento se iluminar el led de presencia red y el display indicar T 11 of 00 En caso contrario aceptarse que la central sea en tensi n verificar las entradas activadas ver la descripci n de las diagnosticas del display e Activar uno a la vez los dispositivos de seguridad y verificar que a display figure la escrita de diagnostica relativa Por ejemplo hacer intervenir la ictoc lula y verificar que figure a display el mensaje 010 Entrar en el men y seleccionar la voz apprendimento conocimiento Le prime ue manovre servono per identificare l inizio e la fine della corsa dei motori Las primeras dos maniobras sirven para identificar el principio y el fin de la corrida de los motores Las dos siguientes sirven a notar el pique de absorci n de los motores durante la conclusi n y la abertura de la cancela En sta fase monitorar los valores visualizados a display A final de la fase de conocimiento sobre el display ser visualizado 0k en el caso de correcta programaci n o en el caso hayan aparecido errores Para salir desde la programaci n pulsar el bot n de selecci n elmpostar correctamente los niveles de fuerza antiap
79. mando de START sobre el primer canal de radiofrecuen cia e f activaci n del mando de START sobre el canal para peatones eph0 activaci n de la entrada de las fotoc lulas en conclusi n sobre la tornil lera ephoA activaci n de la entrada de las fotoc lulas en conclusi n y en abertura sobre la tornillera ebar activaci n del borde de seguridad est 0 impulso de parada eent E asistencia del sensor a encoder sobre el primer motor eent asistencia del sensor a encoder sobre el segundo motor 0 D activaci n del mando de abertura con 0 ech activaci n del mando de conclusi n con 0C eped activaci n del mando de entrada para peatones e3 activaci n del sensor antiaplastamiento sobre el motor 1 e3 activaci n del sensor antiaplastamiento sobre el motor 2 Datos T cnicos eAlimentaci n de la automaci n 230V 50 60Hz Fusible de protecci n primaria transformador T1 25A 230V Fusible de protecci n de la salida accesorios 24V F2 5A Recibidor integrado 433Mhz cabida m xima 76 c digos radio eTemperadura de funcionamiento 20 55 Potencia nominal m xima de los motores 70W 70W ePotencia m xima de la salida relampagueante 25W e Potencia m xima de la salida esp a cancela abierta SCA 5W Dispositivo el ctronico anti aplastamiento amperom trico a encoder F A Q Las preguntas m s frecuentes Porqu elegir un emisor rolling code
80. miento s lo con el motor 1 0 funci n no habilitada funci n habilitada een funcionamiento encoder permite el funcionamiento del sistema tambi n en caso de aver a del encoder el port n se bloquea despu s de su salida y sobre el display viene visualizada la escrita ENC1o ENC2 en 0 encoder no habilitado en 1 encoder habilitado ATENCION el funcionamiento del sistema sin encoder se tiene que considerar una gesti n de emergencia En sta modalidad cada obst culo encontrado por los motores manda la detenci n Cuando el encoder es activo en cambio y con t 0 cada obst culo encontrado por los motores manda la inversi n del movi miento de casi 30cm 8 ess soft start permite a los motores de efectuar una salida dulce y a una velocidad reducida para disminuir la incitaci n de las partes mec nicas del esta blecimiento Activando sta funci n los motores erogan una fuerza minor en su fase de salida 55 funci n no habilitada 65 1 funci n habilitada e0 funcionamiento open close la entrada en tornillera de START se vuelve OPEN y la entrada en tornillera de PARA PEATONES se vuelve CLOSE En sta modalidad un mando abre la cancela y la otra lo cierra sin paradas intermedias Las funciones START y PARA PEATONES permanen activables con el radiomando rispectivamente sobre el primer y sobre el segundo canal 0 0 funci n no habilitada 0 1 funci n habilitad
81. n dass keine Gegenst nde oder Personen auf dem Arbeitsweg des Tors sind eF hren Sie einige Testzyklen aus um den korrekten Betrieb der gesamten Anlage zu berpr fen eF hren Sie die Anschlagskraftmessungen des Tors gem ss der Bestimmungen der Norm EN12445 aus N B Nel caso vi sia un interruzione di alimentazione durante la manovra di aper tura o chiusura dell automazione al ritorno dell alimentazione il primo comando di START comander la chiusura totale per cercare le battute di arresto Lasciare quindi che sia completata la manovra di chiusura sino all arresto e poi immettere nuovi comandi D F gt er Anzeiger Rolling Code Empf nger e die obere Strecke zeigt den Encoder Betrieb des ersten Motors an lt wahrend die untere Strecke denjenigen des zweiten Motors anzeigt by 0 eingestellte Sender agg radoc AN 6 2299 5100 radioc Speicher vorgang Funksteuerungen elh Speichervorgang der Funksteuerungstaste auf dem ersten Kanal START Impuls e2ch Speichervorgang der Funksteuerungstaste auf dem zweiten Kanal Impuls PEDONALE Fus sg nger F r den Zugriff auf die Men s oder die Ausf hrung eines Vorgangs ist die Taste ENTER E kurz zu dr cken Wird der Druck auf derselben Taste verl ngert kann zum oberen Men zur ckgekehrt oder der verlangte Vorgang annulliert werden ESC Funktion F r die Navigation in den Men s sind die Tasten Pfeil o
82. n 30 bis 150 eingestellt werden esfaa Verz gerungszeit Offnung Motor 2 In der ffnungsphase verz gert der zweite Motor seinen Start Die von Stagnoli eingegebene Standardzeit ist 1 und kann von 0 bis 10 Sekunden eingestellt werden esfac Verz gerungszeit Schliessung Motor 1 In der Schliessphase verz gert der erste Motor seinen Start Die von Stagnoli eingegebene Standardzeit ist 3 und kann von 0 bis 10 Sekunden eingestellt werden ACHTUNG Vor der Einstellung der Bremsungen ist zu kontrollieren dass das Tor korrekt ausgeglichen ist Tats chlich haben die Motoren in dieser Phase weniger Kraft und die Einstellung dieses Parameters kann den Sicherheitsgrad der Anlage beeinflussen Kontrollieren Sie nach Beendigung der Einstellung dieser Parameter die Anschlagskr fte des Tors er lap gebremster Weg Offnung Die Zentrale bremst den Lauf der Motoren auf 8 dem letzten St ck ihrer ffnungsphase Der von Stagnoli eingegebene Standar dlauf ist 20 cm und kann von 0 bis 70 cm eingestellt werden f r 1 8m Fl gel er ch gebremster Weg Schliessung Die Zentrale bremst den Lauf der Motoren auf dem letzten St ck ihrer Schliessphase Der von Stagnoli eingegebene Standar dlauf ist 20 cm und kann von 0 bis 70 cm eingestellt werden f r 1 8m Fl gel ACHTUNG Vor der Einstellung der Bremsungen ist zu kontrollieren dass das Tor korrekt installiert ist Tats chlich haben die Motoren in dieser
83. n contr le diagnostic d int grit des d tecteurs encodeur et amp ro m trique est effectu avant chaque d marrage des moteurs te 0 4 hobilit e t ez1fonction hobilit e Effacer ereset parametri reset param tres pour effacer les param tres des r glages et des fonctions r gl s et reprogrammer les param tres d usine une fois entr dans le menu cancela effacer se porter sur l inscription reset parametri sur le display et appuyer sur la touche ENTER Le message RESE sera affich et clignotera tant que l intention de reprogrammer tous les param tres ou d annu ler l op ration ne sera pas confirm e Les param tres ins r s par d faut sont ttca aped 70 sfaa 1 sfac 3 rlap 20 rkhz20 sbat 5 v fma 50 fmkz50 fma 50 fm2c 50 tserz2 fend 30 ur ba 0 deg en sv 0 ar 0 re 0 Im 0 en 1 55 0 ac 0 t 0 20 0 cf 0 aF0 te 0 ecancela 1 radiocomando efface 1 radiocommande pour effacer le code d un metteur une fois entr dans le menu cancela effacer se porter sur l inscription cancela 1 radiocomando sur le display et appuyer sur la touche ENTER Le mes sage PREMI sera affich Appuyer alors sur la touche de l metteur effacer Si l op ration est correctement men e terme le message OK sera affich Dans le cas contraire ERR sera affich ecancela tutta memoria radio efface toute la m moire radio pour effacer tous les metteurs enregistr s une fois en
84. n maximum des moteurs Programmer en suite ies valeurs des r glages M etf de fa on ce qu elles soient sup rieures aux valeurs relev es si fm fm fm2a et ont des valeurs basses indiquent une plus grande sensibilit anti crasement En cas de consommation particuli rement lev e v rifier qu il n y ait pas d en droit ou le portail rencontre une plus grande friction Pour ce faire il suffira de 8 contr ler les valeurs correspondant au courant instantan absorb par le moteur durant sa course et affich es sur la deuxi me page cran principale du display Si l op ration est port e terme de facon correcte le message OK sera affich Dans le cas contraire ERR sera affich ATTENTION durant les man uvres d apprentissage la centrale ignore les com mandes de START et PIETON et travaille avec les param tres de aree program m s M me si les s curit s restent actives s assurer qu il n y ait pas d objets ou de personnes sur la trajectoire de travail de la fermeture Lire le code est possible de v rifier si un code a d j t m moris Se positionner sur l in scription codice lire le code et appuyer sur la touche ENTER pour que le message PREMI appuyer soit affich sur le display En appuyant alors sur la tou che de l metteur que l on d sire v rifier une s rie de pages crans de description du code seront visualis es
85. ndernfalls ist sicherzustellen dass die Zentrale spannung uren ist und es sind die aktivierten Eing nge zu pr fen s Beschreibung der Displaydiagnostik Die Sener Nae MUT Hen einzeln nacheinander aktivieren und pr fen dass auf dem Display die Schriff der jeweiligen Diagnostik erscheint Es ist z B der Ein griff der Fotozelle auszul sen und zu pr fen dass auf dem Display die Meldung pho erscheint Greifen Sie auf das Men zu und w hlen Sie den Punkt apprendimento Erler nung aus Die ersten beiden Bedienungen sollen den Beginn und das Ende des Motorenlaufs identifizieren Die beiden Folgenden sollen die Absorptionsspitze der Motoren w hrend der Schliessung und Offnung des Tors feststellen In dieser Phase sind die am Display angezeigten Werte zu berwachen Am Gen der Lernphase wird auf dem Display bei einer korrekten Program mierung 0 angezeigt oder f f wenn Fehler aufgetreten sind Dr cken Sie zum Verlassen der Programmierung die Auswahltaste Stellen Sie die Stufen der Quetschsicherheitskraft bei der Offnung und Schlies sung korrekt ein die h her als die w hrend des Lernvorgangs angezeigten Ma ximalwerte sein m ssen ACHTUNG Diese Einstellung kann den Sicherheitsgrad der Automatik beeinflus sen W hrend der Lernbewegungen EEN die Zentrale die Anweisungen START und PEDONALE Fussganger und arbeitet mit den ausgew hlten Kraftparame tern Obgleich die Sicherheitsvorrichtungen aktiv bleiben ist sicherzustelle
86. ndr visualizado el mensaje K En caso contrario ERR ecancela tutta memora radio cancela toda la memoria radio para cance lar todos los transmetidores registrados una vez entrados en el men cancella cancela llevarse sobre la escrita cancela tutta memoria radio cancela toda la memoria radio del display y pulsar el bot n ENTER Vendr visualizado el mensaje PRG que se iluminar hasta cuando no ser confirmada la intenci n de cancelar todos los c digos registrados pulsando el bot n ENTER o de anular la operaci n prolongando la presi n del mismo bot n N B Para terminar la cancelaci n de la memoria radio hay que confirmar dos veces la intenci n de efectuar la cancelaci n misma elimina toda la memoria radio PRG Idioma El display puede visualizar los mensajes en dos idiomas talano e englsh Para escoger el idioma de funcionamiento llevarse sobre el men ingua idioma y pulsar ENTER llevarse ahora sobre el idioma talano o english y confirmar pulsando nuevamente ENTER Conocimiento Esta operaci n permite a la automaci n de establecer autom ticamente el princi pio y el final de la corrida individuando los respectivos golpes mec nicos Antes de continuar con sta operaci n asegurarse que la 4 sea fijada y que la funci n en de la central sea activa Stagnoli suministra la central con sta funci n ya activada Visualizada la voz apprendimento conocimiento sobre el display pulsar el bo t n ENTE
87. normal opening movement ar function not enabled ar 71 function enabled er amp energy saving keeps the photocells off while the system is not active per mitting energy saving The photocells therefore remain active only while the leaves are in movement and during t t Ca re 0 function not enabled re function enabled Connect the current feed 24V of both the transmitter and receiver of the pho tocells at flasher exit el one motor operation of the system only with motor 1 0 function not enabled 1 function enabled een encoder operation allows the system to operate also if there is an encoder malfunction the gate blocks shortly after the start of movement and the display shows ENClor END en 0 encoder not enabled en 1 encoder enabled WARNING the operation of the system without encoder is to be considered as being an emergency operation In this mode every obstacle encountered by the motors will make it stop When the encoder is active instead operating with t 0 each obstacle encountered by the motors commands an reversal of movement by approximately 30cm ess soft start allows the motor to undertake a soft start and at reduced speed to diminish stress of the mechanical parts of the system Activating this function the motors deliver less power in the starting phase 55 0 function not enabled 55 zl function enabled e0 open close function START terminal input becomes OPEN
88. oder abilitato ATTENZIONE il funzionamento del sistema senza encoder amp da considerarsi una gestione di emergenza In questa modalit ogni ostacolo incontrato dai motori ne comanda l arresto Quando l encoder attivo invece e con ogni ostacolo incontrato dai motori comanda l inversione del movimento di circa 30cm ess soft permette ai motori di effettuare una partenza dolce e a velocit ridotta per diminuire la sollecitazione delle parti meccaniche dell impianto At tivando questa funzione i motori erogano una forza minore nella loro fase di partenza F gt 55 0 funzione non abilitata 55 1 funzione abilitata 0 funzionamento open close l ingresso in morsettiera di START diventa OPEN e l ingresso in morsettiera di PEDONALE diventa CLOSE In questa modalit un comando apre il cancello e l altro lo chiude senza fermate intermedie Le funzioni START e PEDONALE rimangono attivabili con il radiocomando rispettivamente sul primo e sul secondo canale 0 0 funzione abilitata 0 1 funzione abilitata eit inversione totale attivando questa funzione motori se incontrano un osta colo in fase di apertura invertono il moto e chiudono del tutto il cancello In fase di chiusura se incontrano un ostacolo invertono il moto e si aprono del tutto Se la funzione non attivata in fase di apertura i motori si arrestano nel caso incontrino ostacoli mentre in fase di chiusura invertono il m
89. olabile da 20 a 99 ef forza anti schiacciamento del motore 1 in chiusura la forza anti schiac ciamento della prima anta del cancello espressa in percentuale rispetto alla forza massima che lo stesso pu erogare Il valore impostato di default da Stagnoli 50 ed regolabile da 20 a 99 efm2a forza anti schiacciamento del motore 2 in apertura la forza anti schiac ciamento della seconda anta del cancello espressa in percentuale rispetto alla for za massima che lo stesso pu erogare Il valore impostato di default da Stagnoli 50 ed regolabile da 20 a 99 ef m2C forza anti schiacciamento del motore 2 in chiusura la forza anti schiac ciamento della seconda anta del cancello espressa in percentuale rispetto alla for za massima che lo stesso pu erogare valore impostato di default da Stagnoli 50 ed regolabile da 20 a 99 ATTENZIONE l impostazione di questi due parametri pu influire sul grado di sicurezza dell impianto stesso Stagnoli consiglia di impostare questi parametri con un margine di sicurezza tale che risultino almeno 10 rispetto al massimo della corrente consumata dai motori rispettivamente in fase di apertura e di chiu sura Questa si ded leggere durante la corsa dei motori sul display nella seconda E rinci X e k n la efmc bassi di valore indicano una maggiore sensibilit anti 1 gt Verificare al termine dell installazione che le for
90. olling code de type HCS300 STAGNOLI avec des milliards de combinaisons ou des codes fixes de type HT53200 13 bit ou la partie fixe d un code rolling code 28 bit SN est possible de m moriser jusqu 76 codes En entrant dans le menu 200 radioc ajout radiocommande se porter sur l inscription du display IN ou 2th et choisir le canal que l on veut ajouter En appuyant sur ENTER l inscription premi appuyer sera ensuite visualis e Appu er sur la touche que l on veut m moriser l inscription 0K sera alors visualis e si op ration est port e terme de fa on correcte l inscription eff si des erreurs d enregistrement se sont produites ou l inscription full si la m moire du r cepteur est pleine e En installant une antenne externe la centrale et loin du sol la zone de visibilit entre metteurs et centrale augmente Se rappeler aussi que les parties m talli ques et en b ton arm si plac es entre la centrale et le r cepteur diminuent la capacit de r ception de ce dernier R glages et temps de fermeture automatique c est le temps qui s coule entre l ouver ture compl te du portail et sa fermeture qui se produit en mode automatique Si la photocellule est occup e le temps de est calcul partir du moment o la photocellule se lib re Le temps de d faut programm par Stagnoli est de 10 sec et est r glable de 1 240 sec eaped ouverture pi tonne c est la longueur de la cour
91. ollows progressive from O to 75 indicates the position occupied by the 8 transmitter in the memory If the transmitter is not found in the memory the display will show ethird and fourth screens show the hexadecimal code of the transmitter Statistics screens The control board has four statistics screens that are viewed by keeping the key ENTER pressed once the display is positioned on the main menu efirst screen 01 where E2 indicates the motor Hermes at 24V and 01 the sof tware version esecond and third screens 0000 0000 indicates the number of complete mano euvres undertaken efourth screen indicates the stroke in the memory Diagnostics screens The control board can recognise problems or alarms that can occur in the system therefore it can signal some messages on the main display to allow the problem to be identified el rf activation of the START command on the first radio frequency channel el r activation of the START command on the pedestrian channel eph0 activation of photocells input in closing on the terminal board ephoA activation of photocells input in closing and in opening on the terminal board ebar activation of the safety rib est 0 stop impulse een Cl operation of the sensor with encoder on the first motor een C2 operation of the sensor with encoder on the second motor 0 D activation of the opening command with 0 C e
92. omatique Si a let 2p 0 une commande de START donn e alors que le portail est en ouverture arr te le portail et charge le temps tt C de fermeture automatique ba bloc impulsions durant l ouverture la centrale ignore les impulsions de START durant la phase d ouverture ba 0 fonction non habilit e ba 1 fonction habilit e ebp bloc impulsions durant la pause la centrale ignore les impulsions de START durant la pause entre l ouverture et la fermeture automatique c bp 0 fonction non habilit e bp 1 fonction habilit e Ces fonctions permettent au portail de ne pas se bloquer ou de ne pas intervertir la course cause d autres commandes de START comme par exemple dans des copropri t s ecf fermeture rapide si il y a un passage travers les photocellules durant la phase d ouverture ou quand le portail est ouvert le temps du r glage tt C si activ ou sup rieur 3 sec est automatiquement r duit 3 sec cr fonction non habilit e cr l fonction habilit e 2 fonctionnement ouvre ferme 2 1 fonction habilit e chaque impulsions 8 de START le mouvement du portail intervertit la direction OUVERTURE FERME TURE 2p 0 fonction non habilit e la s quence de mouvement du portail devient OU VERTURE ARRET t t Ca FERMETURE STOP 0 pr clignotement apr s la commande d ouverture du portail le clignotant ou la lumi
93. on 20 bis 99 ein gestellt werden ef Quetschsicherheitskraft Motor 1 in der Schliessung Es handelt sich hierbei um die Quetschsicherheitskraft des ersten Schwingfl gels des Tors die mit Bezug auf die Maximalkraft die dieses abgeben kann in Prozenten angegeben wird Der von Stagnoli eingegebene Standardwert ist 50 und kann von 20 bis 99 ein gestellt werden efm2a Quetschsicherheitskraft Motor 2 in der ffnung Es handelt sich hierbei um die Quetschsicherheitskraft des zweiten Schwingfl gels des Tors die mit Be zug auf die Maximalkraft die dieses abgeben kann in Prozenten angegeben wird Der von Stagnoli eingegebene Standardwert ist 50 und kann von 20 bis 99 eingestellt werden ef m Quetschsicherheitskraft Motor 2 in der Schliessung Es handelt sich hier bei um die Quetschsicherheitskraft des zweiten Schwingfl gels des Tors die mit Bezug auf die Maximalkraft die dieses abgeben kann in Prozenten angegeben wird Der von Stagnoli eingegebene Standardwert ist 50 und kann von 20 bis 99 eingestellt werden ACHTUNG Die Einstellung dieser beiden Parameter kann den Sicherheitsgrad der Anlage beeinflussen Stagnoli empfiehlt diese Parameter mit einer Sicherhei tsspanne einzustellen die mit Bezug auf den maximal von den Motoren in der Offnungs und SchlieBphase verbrauchten Strom mindestens 10 ist Diese kann w hrend des Laufs der Motoren auf dem Display der zweiten Hauptbildschirman zeige abgelesen werden
94. on and regulate the parameter t 5 ef accordingly efend end force thrust on striking this is the force that the motors exercise in closing once the limit stop strikers are reached This is stated in percentages compared with the maximum force that the motors themselves can exercise The default value set by Stagnoli is 30 and it can be regulated from 20 to 70 WARNING regulate fend with a low value should the gate structure be very light The regulation of this parameter can influence the time and force with which the gate works in the final phase of the stroke Functions C automatic closing automatic closing of the gate after it has opened fully 3 0 function not enabled ca 1 function enabled Set the t t 2 regulation to customise the time that must pass from the end of ope ning to the start of automatic closing N B If ca 1 and hl a START command activated while the leaves are opening will stop the gate and load the t t 8 time for automatic closing ba impulse block during opening the control board ignores the START impul ses during the opening phase ba 0 function not enabled ba 1 function enabled ebp blocks impulses during pause the control board ignores the START impul ses during the pause between opening and automatic closing t Each START command received during the pause between opening and automatic closing recharges the t t C time bp 0 not enabled bp 1 function enabled
95. oschloss von 12V Mosfet Elektroschloss Klemme Ausg nge Kontrollleuchte Tor ge ffnet SCA Zubeh r Elektroschloss Relais Kontrollleuchte Tor ge ffnet PTC 0 1A Encoder Klemme Funkantenne Widerstandsf hige Flanke Jumper Eingangsklemme Flanke Steckverbinder Eing nge Steuerungen Steckverbinder Encoder Motor Steckverbinder Motoren Blinklicht Versorgungsklemme Zentrale von 24V Schnellsicherung 2 5A Elektroschl sser Kontrollleuchte Tor ge ffnet SCA WICHTIG verbinden Sie den Encoder mit der Steuerung unter Beachtung der Farben der angegebenen Kabel id Motor 2 braun Motor 1 und Motor 2 gr n Motor 1 weiss Motor 1 un ar n Motor 2 E C E E SE LII 94 av SIE o lo 24V 1mot2 25W Blinklicht Fussg nger gemein Start Fotozellen in Fotozellen in der Schliessung Offnungund Schliessung Die Versorgungsleitung 230V IN zur Automatik muss durch einen Magnetschal ter oder ein Sicherungspaar von 5A geschitzt werden Ein Differenzialschalter wird em pfohlen ist jedoch nicht unbedingt notwendig wenn er schon oberhalb der Anlage vorhanden ist Versorgen Sie die Automatik ber ein Kabel von 3x1 5mm2 Phase Nullleiter Erdleitung Wenn der Abstand zwischen der Zentrale und der Verbindung zur Erdungsanlage gr s ser als 30 m ist muss ein Erdschlus
96. oto di 30cm prima di arrestarsi t 0 funzione non abilitata it 1 funzione abilitata e2b due coste di sicurezza Funzionamento con due coste di sicurezza 8k2 collegate in parallelo 2b 0 funzione non abilitata 2b 1 funzione abilitata ecf funzionamento della ricevente integrata a codice fisso f 0 la ricevente funziona con i codici rolling code cf 1 la ricevente funziona can i codici fissi Il funzionamento a codice fisso o rolling code della ricevente viene visualizzato anche nella schermata iniziale del display dove 00 indica il funzionamento rolling code e f 00 a codice fisso Il ricevitore pu memorizzare codici rolling code di tipo HCS300 STAGNOLI con miliardi di combinazioni o codici fissi di tipo HT53200 a 13 bit o la parte fissa di un codice rolling code 28 bit SN 2 allarme Allarme che segnala il cancello rimasto aperto Questa funzione attiva l uscita SCA dopo che siano passati 20 secondi dal termine del tempo re golato da tt 8 e il cancello risulti ancora aperto al 0 funzione non abilitata al 1 funzione abilitata ete test Viene effettuato un controllo diagnostico di integrit dei sensori ad encoder ed amperometrico prima di ogni avvio dei motori te 0 funzione non abilitata te l funzione abilitata Cancella ereset parametri per cancellare i parametri delle regolazioni e delle funzioni regolate e reimpostare quelle di fabbrica una volta entrati nel men Cancela
97. r 2 in der Offnung d ma Quetschsicherheitskraft Motor 2 in der Schliessung et ser Aktivierungszeit Elektroschloss ef end abschliessende Stosskraft im Anschlag 4 automatische Schliessung eb a blockiert Impulse w hrend der ffnung eb p blockiert Impulse w hrend der Pause e Schnellschliessung e Betrieb Offnen Schliessen epi Vorblinken eS V Saugschloss eal Widderstoss Offnung ef Energieersparnis elm Betrieb mit einem Motor een Encoder Betrieb eS S Soft Start Betrieb Open Close eit Totalumkehr nach dem Antreffen eines Hindernisses 2 zwei Sicherheitsflanken ecf Betrieb des Festcodeempf ngers eal Alarm et Diagnostikkontrolle vor jedem Start ereset parametri Einstellung der Herstellerparameter ecancela 1 radocomando L schung eines Senders ecancela tutta memoria radi L schung aller registrierten Sender 8 Hinzuf gen von Funksteuerungen Vor der Speicherung eines Senders ist sicherzustellen dass er mit der Typo logie des integrierten Empf ngers kompatibel ist in der ersten Displayanzeige erscheint wenn es sich um einen Rolling Code Empf nger handelt oder bei ei nem Festcode Empf nger Der Empf nger kann Codes des Rolling Code vom Typ HCS300 STAGNOLI mit Milliarden von Kombinationen speichern oder Festcodes vom Typ HT53200 mit 13 Bit oder den festen Teil eines Rolling Code Codes 28 Bit SN
98. s code fixe en revanche disposent de 1024 combinaisons de codes qui ne changent pas chaque transmission La centrale peutelle g rer le fonctionnement du moteur avec les batteries d urgence Oui Pour utiliser les batteries d urgence utiliser le kit pr vu cet effet fourni par Stagnoli La centrale ne reconnait pas l metteur Pourquoi S assurer d utiliser une centrale et des metteurs du m me type Il est possible de v ri fier sur la premi re page cran le type de r cepteur utilis par la centrale et le changer ventuellement en programmant le param tre Cf Lorsqu elle arrive aux but es d arr t l automatisation intervertit le mouvement au lieu de s arr ter Pourquoi Une des causes qui peut provoquer la perte de r f rences est le fait que l automati sation ait t activ e alors qu elle tait d bloqu e Pour que la centrale retrouve ses r f rences il suffit de couper la tension de s assurer que l automatisation soit bloqu e et de remettre ensuite la tension la centrale D s la premi re impulsion de start la centrale retrouve ses r f rences Donn es Techniques e Alimentation de l automation 230V 50 60Hz Fusible de protection primaire transformateur T1 25A 230V eFusible de protection de la sortie accessoires 24V F2 5A eR cepteur int gr 433Mhz capacit maximum 76 codes radio eTemp rature de fonctionnement 20 455 e Puissance nominale maximum des moteurs 7OW 70W ePui
99. s normally closed if they are not used must be bridged with an ordinary terminal 24V If there are more N C contacts for the same input they must be placed in series example 1 and ph2 in the diagram Inputs of N O type contacts normally open if not used must be left free If there are more N O contacts for the same input they must be placed in parallel example st1 and st2 in the diagram CB F Operating procedure at the first start up eUndertake the electric wiring for the plant and check when the card is switched off E eCheck that the mechanical stops have been instal display JOLT led correctly and that the wiring of the two motors TOF with the respective encoders has been done JOL Unblock the gate and check its movement the hin indicator for TOE ged leaves must have no obstacles in their path power supply he stroke of the leaves must not have any stiff points during movement it must be smooth Block the gate and supply current to the control board At this point the electric mains detection led will light up and the display will show I 00 or f 00 If this does not occur check that the control board receives power and check the inputs activated see the description of the diagnostics on the display e Activate the safety devices one at a time and check that the display shows the relative diagnostics wording For example activat
100. s der Produkt E24 mit den technischen Erfordernissen der EG Richtilienen bereinstimmt Declaraci n de conformidad El suscrito Sr Francesco Albiero declara que el producto E24 es confor me a los criterios t cnicos requeridos por las directivas comunitarias 2004 108 CE EMC 2006 95 CE LVD 99 05 CE R amp TTE Costruttore e rappresentante autorizzato Authorized producer and representative Constructeur et repr sentant autoris Genehmigter Hersteller und Vertreter Fabricante y representante autorizado Stagnoli T G srl Via Mantova trav 1 105 A B 25017 Lonato BS Italy tel 39 0309139511 fax 39 0309139580 i Stagnoli T G srl Via Mantova trav I 105A B 39 0309139511 39 0309139580 info stagnoli com The President www stagnoli com
101. s in der N he der Zentrale vorgesehen werden Die Verkabelungen m ssen bei ausgeschalteter Zentrale ausgef hrt werden Bei den Eing ngen handelt es sich um NC Kontakte Ruhekontakte die wenn nicht benutzt mit einer normalen Klemme zu berbr cken sind Wenn f r denselben Eingang mehrer NC Kontakte vorhanden sind m ssen sie seriengeschaltet werden Beispiel ph und ph2 im Plan Die Eing nge der NO Kontakte Schliesserkontakt sind wenn nicht benutzt frei zu las sen Wenn f r denselben Eingang mehrer NO Kontakte vorhanden sind m ssen sie parallel geschaltet werden Beispiel st und st2 im Plan F gt Betriebsverfahren beim ersten Start edie von der Anlage verlangten elektrischen Ver kabelungen ausf hren und sie bei ausgeschalteter Karte pr fen L displ ePr fen dass die mechanischen Sperren korrekt in 2 PM stalliert und die Verkabelung der zwei Motoren mit den jeweiligen Encodern durchgef hrt worden ist T 0 H Of CL Tor entblocken und seine Bewegung pr fen die LED f r Met going 00 d rfen auf ihrem Weg auf kein Hin zanwesenheit dernis treffen Der Weg der Schwingfl gel darf w hrend der Bewegung die fl ssig sein muss keine harten Stellen aufweisen eTor blockieren und Zentrale speisen An dieser Stelle wird sich die Led f r die Netzanwesenheit einschalten und das Display wird 00 oder f 00 anzeigen A
102. se exprim e en centi m tres de l ouverture partielle c est dire de la modalit pi tonne La valeur de d faut programm e par Stagnoli est 7O et est r glable de 30 150 esfaa temps de retard en ouverture du moteur 2 En phase d ouverture le se cond moteur retarde son d part Le temps de d faut programm par Stagnoli est 1 et est r glable de O 10 secondes esf C temps de retard en fermeture du moteur 1 En phase de fermeture le premier moteur retarde son d part Le temps de d faut programm par Stagnoli est 3 et est r glable de O 10 secondes ATTENTION avant de programmer les ralentissements contr ler que le portail soit correctement quilibr Durant cette phase en effet les moteurs ont moins de force et la programmation de ce param tre peut influencer le degr de s curit de l installation Contr ler une fois le r glage de ces param tres termin les forces d impact du portail er ap course ralentie en ouverture la centrale ralentit la course des moteurs dans la partie finale de sa phase d ouverture La course de d faut programm e par Stagnoli est 20cm et est r glable de O 70cm vantail de 1 8 8 er Ch course ralentie en fermeture la centrale ralentit la course du moteur dans la partie finale de sa phase de fermeture La course de d faut programm e par Stagnoli est 20 cm et est r glable de O 70 cm vantail de 1 8 m ATTENTION a
103. ssance maximum de la sortie clignotant 25W ePuissance maximum de la sortie voyant portail ouvert SCA SW Dispositif lectronique anti crasement amp rom trique encodeur ANTENNE VOYANT PORTAIL OUVERT EN SERRURES gm LECTRIQUES T je 2 ZOE meg moa m O ru E x gt c Ez 43024 E o ims i 0 24 1 mic 5 GN TX RX TX Fu PHOTOCELLULES PHOTOCELLULES n EN FERMETURE EN OUVERTURE Y T BATTERIES DEE CENTRALE DU CHARGEUR DE BATTERIES ATTENTION Si un chargeur de batteries est utilis la centrale de commande est alimen t e par la centrale du chargeur de batteries C24 raccord e un transformateur Pour les d tails du raccordement voir les instructions correspondantes Li 222222222 20 1 not gt a Lin EI O 3 an imp 215 x 94 2 m zl y ve L2 E312490 SS RENCODEUR ALIMENTATION 1687 TELA ECH d 24V 0 24 RANSFORMATEUR COMMANDES O 230 b d CORDON DE S CURIT MOTEUR 2 eh MOTEUR 1 8 E24 von Stagnoli ist die f r Schwingfligelmotoren von 24V und dem jeweiligen Zubeh r entwickelte Steuerzentrale Ausschliesslich aus Materialien erster Wahl realisiert ist sie entwickelt worden um in der Ruheposition geringe
104. t O 24 lt Or TX 1 M FOTOCELULAS EN FOTOCELULAS nt CONCLUSION EN ABERTURA a o Ti Bh db CENTRAL CARGABATERIAS ATENCI N Si se utiliza el cargabaterias la central de mando es alimentada por la central cargabaterias C24 conectada a un transformador Para ver el detalle de la conexi n con sultar la hoja de instrucciones incluida 4 DE L SINOIVId Vad 1 38 NNWOD 205 55 U Be E 2 8 NNWO z d TRANSFORMADOR MANDOS VW 1 BORDES DE d SEGURIDAD 1i MOTOR 2 MOTOR 1 2061 19 8 C Dichiarazione di conformit LGB sottoscritto Francesco Albiero dichiara che il prodotto E24 conforme a tutte le F norme tecniche relative al prodotto entro il campo di applicabilit delle Direttive Comunitarie D Declaration of Conformity mE The undersigned Francesco Albiero declares that the product E24 is in complian ce with the technical requirements of the European Directives D claration de conformit Le soussign Francesco Albiero d clare que le produit E24 est conforme tou tes les normes techniques relatives au produit dans le champ d applicabilit des Directives Communautaires Konformit tserkl rung Der Unterzeichnete Francesco Albiero erkl rt das
105. tausgangs 25W eMaximale Leistung des Kontrollleuchtenausgangs Tor offen SCA SW Elektronische Quetschsicherungseinrichtung Strom Encoder F A Q H vfig gestellte Fragen Sobald der Antrieb die Endschalter erreicht kehrt er die Laufrichtung um statt sich auszuschalten Warum Die Steuerung mag die Koordinaten verloren haben wenn der Antrieb wahrend der Entriegelungsphase bet tigt wurde Damit die Steuerung die notwendigen Koordinaten wieder findet gen gt es die Spannung aufzuh ren und sicherzustellen dass der Antrieb blockiert ist Dann muss man der Steuerung Spannung wieder geben Nach dem ersten Startbefehl wird die Steuerung die Koordinaten finden ANTENNE KONTROLL FLEKTROSCHL SSER LEUCHTETOR 8 d GE FFNET MM T RE 0 ba nor EI 5 55 Anni D ONNSSANHIS ANN ONNN44O NI N3T13Z0104 d TRANSFORMATOR TX FOTOZELLEN DER FOTOZELLEN SCHLIESSUNG IN OFFNUNG 1 BATTERIEN KARTE VOM BATTERIELADEGER T WICHTIG wenn ein Batterieladeger t benutzt wird wird die Steuerung von der Kar te des Batterieladeger ts C24 die mit einem Transformator verbunden ist versorgt Lesen Sie bitte die entsprechende Anleitung wo die Verbindungsangaben beschrieben sind Li 222222222 20 d nord Lin EI O e 3 an v e 1 2 E312490 _ en VERSORGUNG C g HIONVOSSNA
106. tected values if fm fmi fm and fmt have a low value this indicates greater anti crushing sensitivity Should consumption be shown to be excessively high check that there are no areas where the gate has greater friction To do this monitor the values showing instant absorbed power by the motors during their stroke and presented in the second main screen of the display If the operation has been carried out correctly the message OK will appear i this has not been carried out correctly the message R will appear WARNING during learning manoeuvres the control board will ignore START and PEDESTRIAN commands and will work with the force parameters that have been set Even if the safeties remain active ensure that there are no objects or people in the area of operation of the gate Read code It is possible to check if a code has already been memorised Position yourself on the wording read Code press ENTER the display will show the message PREMI PRESS Now press the transmitter key that must be checked a series ii describing the code will be viewed efirst screen 5 Qlor The first letter indicates the manufacturer of the radio control where means Stagnoli and a generic manufacturer The second letter indicates the type of code where indicates a rolling code and a fixed code The last two indicate the code of the key that was pressed esecond screen P_00 where P indicates the word position and the number that f
107. tr dans le menu Cancela effacer se E sur l inscription cancela tutta memoria radio sur le display et appuyer sur a touche ENTER Le message PRG sera affich et clignotera tant que l intention d effacer tous les codes enregistr s en appuyant sur la touche ENTER ou d annuler l op ration en prolongeant la pression de la touche ne sera pas confirm e N B Pour porter 2 de la m moire radio terme il est demand de confirmer deux fois la volont d effacer cancela tutta memora radio et PRG Langue um les p sages sur le display peuvent tre affich s en deux langues talano et engish Pour choisir la langue de fonctionnement se porter sur le menu lingua langue et appuyer sur ENTER Se porter alors sur la langue talano ou english et confirmer en appuyant de nouveau sur ENTER Apprentissage Cette op ration permet l automation d tablir automatiquement le d but et la fin de la course en d terminant les but es m caniques respectives Avant de pro c der cette op ration s assurer que le portail soit solidement install et que la fonction de la centrale soit active Stagnoli fournit la centrale avec cette fonction d j active Une fois que la rubrique apprendimento apprentissage est visualis e sur le di splay appuyer sur la touche ENTER Les moteurs fermeront alors le portail le rouvriront totalement et r p teront cette op ration encore une fois en indiquant sur le display de la centrale la consommatio
108. vant de programmer les ralentissements contr ler que le portail soit install de facon correcte Durant cette phase en effet le moteur a moins de force et la programmation de ce param tre peut influencer le degr de s curit de l installation Contr ler une fois le r glage de ces param tres termin les forces d impact du portail es hat espace de but e c est l espace en centim tres avant la but e en ouver ture ou en fermeture durant lequel la centrale interpr te les obstacles comme fins de course et s arr te l espace de d faut programm par Stagnoli est de 5 cm et est r glable de 1 10 cm ATTENTION la programmation de ce param tre peut influencer le degr de s curit de l installation L installation doit tre effectu e en respectant les cotes de s curit de facon maintenir ce param tre le plus bas possible et l installation la plus s re possible ev vitesse de ralentissement ce sont les valeurs relatives la vitesse aux quelles les moteurs op rent en phase de ralentissement La valeur de d faut pro gramm e par Stagnoli est 3 et est r glable de 1 4 o la valeur la plus basse indique une vitesse lente et 4 indique une vitesse gale la moiti de la vitesse op rationnelle des moteurs efmh force anti crasement du moteur 1 en ouverture c est la force anti cra sement du premier vantail du portail exprim e en pourcentage par rapport la force maximum qu il peut fournir L
109. y Diode bridge Receiver module PTC 3A for electric lock 12V Mosfet electric lock Open gate SCA accessories electric lock open gate detector output terminal Open gate detector relay PTC 0 1A encoder Radio aerial terminal Resistive rib Jump Rib entry terminal Input controls connector Motor encoder connector Flasher motors Connector Central power 24V terminal Rapid fuse 2 5A GB electric lock open gate detector SCA o 5 A 2 6 E LINE 2 5 5 WARNING Connect the ju ma P 5 encoder to the board 555 e s 23 22 keeping to the colours of TN e the cables as shown 5W E 252 BE 55 E 0 5 C E 52 na ov av 1 mot2 25W TRASFORMER flasher 24 0 edestrian start stop photocell in photocell in closing opening and in closing The current feed line 230V UN to the automation must be protected by a ma gnetometric switch or a pair of 5A fuses A differential switch is recommended but not neccessary if it is already found at the top of the system Feed the device with a 3x1 5mm cable phase neutral ground If the distance betwe en the board and the connection to the grounding system exceeds 30m it is necessary to provide an earth plate near the control board Cabling must be done when the control board is switched off Input NG type contact
110. ze di impatto rispettino la norma 12453 et Ser tempo di attivazione dell elettroserratura il tempo espresso in secondi che intercorre tra la chiusura totale del cancello e l intervento dell elettroserratura II valore impostato di default da Stagnoli amp 2 ed amp regolabile da O a 7 secondi ATTENZIONE verificare che l aggancio della serratura avvenga senza creare at triti e regolare il parametro 5 61 di conseguenza efend forza finale di spinta in battuta la forza che i motori esercitano in fase di chiusura una volta che hanno raggiunto le battute di finecorsa Questa espressa in percentuale rispetto alla forza massima che i motori stessi possono esercitare valore impostato di default da Stagnoli amp 30 ed regolabile da 20 a 70 ATTENZIONE regolare fend un valore basso nel caso la struttura del cancello sia molto leggera La regolazione di questo parametro pu influenzare il tempo e la forza con cui il cancello lavora nella fase finale della sua corsa Funzioni 3 chiusura automatica chiusura automatica del cancello dopo la sua com pleta apertura a 0 funzione non abilitata ca 1 funzione abilitata Impostare la regolazione t per personalizzare il tempo che deve intercorrere tra la fine dell apertura e l inizio della chiusura automatica Se 1 2p 0 un comando di START attivato mentre le ante sono in apertura ferma le ante e carica il tempo t t 8 di chiusura automatica
111. zwischen dem Ende der Offnung und dem Beginn der automatischen Schliessung verlaufen soll ist die Einstellung tt C zu regulieren Wenn C zl und 70 1 ist stoppt eine START Anweisung wenn sie w hrend der ffnung des Tors aktiviert wird das Tor und l dt die t t C Zeit der automati schen Schliessung ba blockiert Impulse w hrend der Offnung Die Zentrale ignoriert die START Impulse w hrend der Offnungsphase ba 0 Funktion nicht aktiviert ba Funktion aktiviert ebp blockiert Impulse w hrend der Pause Die Zentrale ignoriert die START Impulse ur der Pause zwischen der ffnung und der automatischen Schlies sung C Funktion nicht aktiviert bp 1 Funktion aktiviert 8 Mit diesen Funktionen ist es m glich das Tor nicht zu blockieren oder den Weg aufgrund anderer START Anweisungen umzukehren wie z B in einem Miethau skomplex ecr schnelle Schliessung Falls die Fotozellen wahrend der Offnungsphase oder bei offenem Tor aufgrund eines Durchgangs verdeckt werden wird die Einstel lungszeit tt 2 wenn ber Sekunden eingestellt automatisch auf 3 Sekunden verringert cr 0 Funktion nicht aktiviert cr lFunktion aktiviert 2p Betrieb Offnen Schliessen 2 Funktion aktiviert die Bewegung des Tors wird bei jedem START Impuls in eine andere Richtung umgekehrt FFNUNG SCHLIESSUNG 2p 0 Funktion nicht aktiviert die Bewegungsfolge des