Home

C - Fanox

image

Contents

1. the underload adjusted factor should be reduced to 0 6 Reset a After a trip caused by overvoltage the relay resets automatically when the voltage returns to its normal value b After a trip caused by overload the relay waits for approximately 4 minutes before restarting the pump automatically c After a trip caused by underload the relay resets automatically after the time adjusted by the potentiometer 3 PS11 R 2 to 70 min PS16 R 2 to 240 min by reset time factor 4 In order to reset the relay manually cancel the supply of the panel for approximately 10 seconds disconnecting the circuit breaker and then connect it again after this time has passed 150 9001 2000 A15026 FANOX reserves the right to modify technical specifications of products contained within this document without previous notice 6 2008 INSTRUCTIONS MANUAL PROTECTION AND CONTROL PANELS FOR SINGLE PHASE SUBMERSIBLE PUMPS Range Code Models code Ie A Main description e Protections I lt Dry running by undercurrent control I gt Overload with thermal memory U gt Overvoltage if the voltage increases more than 15 over the nominal voltage of the relay it stops the motor Once the voltage returns to its normal value the relay restarts the motor automatically Short circuit e Remote or automatic reset every PS11 R 2 to 70 min PS16 R 2 to 240 min e Indicates cause of tripping e
2. Control point for pressure switch buoy programmer Parts e Plastic case with transparent lid 230 x 250 x 150 mm IP 54 e Circuit breaker 1P N e Fanox PS electronic relay e Contactor e Switch ON OFF e Signalling LED e Connecting strip e 4 cable glands e Auto adhesive support for the capacitor FANOX Connexion diagram To prevent electrical shocks whilst installing or operating the relay disconnect the power supply 1 Check that the auxiliary voltage supply is correct 2 To ensure a correct functioning of the equipment install the capacitor with the uF recommended by the manufacturer of the motor pump Set it using the auto adhesive support Connect it to C and L1 3 Connect the wires of the motor to C CL1 and L1 4 If terminals P1 and P2 are not going to be used for a pressure switch a buoy a timer etc they must be bridged with a cable 5 Connect the power input to the terminals of the circuit breaker T KM f CONTACTOR er E Cee PS11 R RELAY ra i i km E i i a f f POWER INPUT gt OUTPUT TO THE INPUT PUMP PRESSURE CONTACT I A KM CONTACTOR i 2a EEE E 7 PS16 R RELAY O E so i n POWER INPUT PRESSURE CONTACT OUTPUT TO THE INPUT PUMP MANUEL D INSTRUCTIONS COFFRETS D
3. 8 RESET TIME UNDERCURRENT min lout A1 A2 O Current setting Z Full load current This adjustment is to be made according to the nominal current of the motor I indicated in its characteristics plate The value to be set J is the same as I Adjust the potentiometer O with the value J In e g e g I I 13A EI IME 12 D 10 LA 14 FULL LOAD 7 15 ON CURRENT E a I gt 58 3 I lt 7 LA U 9 FULL LOAD CURRENT gt 3 11 se The relay trips with overloads above 1 1 x Iz depending on the curves class 10 Cold Warm Class 10 PAE ASUARAN Edif Artxanda nave 23 48950 Asua Erandio Bizkaia SPAIN Tel 34 94 471 14 09 Fax 34 94 471 05 92 E mail fanox fanox com http www fanox com 2 Setting of the underload trip level undercurrent x T The setting of the underload trip level is made using a potentiometer 2 in which a factor between 0 4 and 0 9 is to be chosen By multiplying this factor by the adjusted J we obtain a current value under which the relay will trip and disconnect the motor The trip is delayed 4 seconds a If the pump is adequately dimensioned the recommended value for this factor is 0 7 Adjust the potentiometer 2 at 0 7 This is applicable for the majority of cases 05 07 04 0 8 xh 0 9 UNDERCURRENT b If the power of the motor is excessively dimensioned and during its functioning unwanted trips should occur
4. E PROTECTION ET CONTR LE POUR POMPES SUBMERSIBLES MONOPHASEES Plage de An pese 230 V R Hz Ig CBM 2 12312 CBM 3 12314 Caract ristiques principales e Protections I lt Manque d eau par sousintensit I gt Surcharge avec m moire thermique U gt Surtension si la tension augmente plus d un 15 sur la tension nominale du relais ceci arr t le moteur Au moment o la tension revient des valeurs normales le relais d marre le moteur automatiquement Court circuit e R armement distance ou automatique toutes les PS11 R 2 70 min PS16 R 2 240 min e Indique la cause du d clenchement e Prise de contr le pour pressostat bou e programmeur etc Composants e Bo te en plastique avec couvercle transparent 230 x 250 x 150 mm IP54 e Disjoncteur 1P N e Relais lectronique Fanox PS e Contacteur e Interrupteur arr t marche e Voyant de signalisation e R glette de connexions e 4 presse toupe e Support autoadh sif pour le condensateur FANOX Sch ma de connexions Avant le montage et la mise en service couper l alimentation secteur pour viter toute d charge 1 V rifier que la tension auxiliaire d alimentation est la correct 2 Installer le condensateur avec les uF sp cifi s par le fabricant de la moto pompe le soutenir avec le support autoadh sif et le connecter en C et L 1 3 Connecter les c bles du moteur en C CL1 et L1 4 Si les terminales P1 et
5. MANUAL DE INSTRUCCIONES CUADROS PARA PROTECCI N Y CONTROL DE BOMBAS SUMERGIBLES MONOFASICAS Rango Is A Motor 230 V 50 60 Hz CV kw 0 37a1 5 1 5 a 2 2 Caracteristicas principales Protecciones I lt Trabajo en vac o controlando la subintensidad I gt Sobrecarga con memoria t rmica U gt Sobretensi n si la tensi n aumenta por encima del 15 de la tensi n nominal del rel ste desconecta el motor En el momento en que la tensi n vuelve a valores normales el rel arranca el motor autom ticamente Cortocircuito Rearme remoto o autom tico cada PS11 R 2 a 70 minutos PS16 R 2 a 240 minutos Se aliza la causa de disparo Toma de control para presostato boya programadores etc Componentes FA Caja de pl stico con tapa transparente 230 x 250 x 150 mm IP54 Magnetot rmico 1P N Rel electr nico Fanox PS Contactor Interruptor ON OFF Piloto de se alizaci n Regleta de conexiones 4 prensaestopas Soporte autoadhesivo para el condensador OX Esquema el ctrico Conexionado Para evitar descargas el ctricas durante la instalaci n o manipulaci n del cuadro asegurarse de que no hay tensi n en la l nea 1 Comprobar que la tensi n de la l nea es la correcta 2 Para asegurar un buen funcionamiento del equipo y de la instalaci n conectar el condensador con los uF especificados por el fabricante de la motobomba Sujetarlo con el soporte autoadhesivo Conec
6. P2 ne vont pas tre utilis s pour un pressostat une bou e un temporisateur etc ils doivent tre pont s avec un cable 5 Connecter l entr e du r seau dans les bornes du disjoncteur KM CONTACTEUR T A A RELAIS PS11 R o km E D AA ORY O NOENSMEUR gt ENTR E R SEAU e L SORTIE POMPE PRESSOSTAT Qe 1 o A KM CONTACTEUR e 5 de Sa Wi RELAIS PS16 R y i 8 5 E 7 i zi i H o it z i fon aa ne i CONDENSATEUR ENTR E R SEAU SORTIE POMPE PRESSOSTAT R glages effectuer En fonction des caract ristiques du moteur et de l installation il est n cessaire d effectuer quelques simples ajustements au relais PS S assurer que le condensateur install uF correspond avec celui sp cifi par le fabricant Signalisation ON relais aliment pe D clenchement par surcharge sousintensit U gt D clenchement par surtension lin 14 11 L A FULL LOAD ON CURRENT I gt 2 I lt 7 9 U gt 3 11 06 05 0 7 0 4 0 8 xh 0 9 UNDERCURRENT 45 15 70 mn I lt A RESET TIME UNDERCURRENT min lout A1 A2 a R glage de l intensit 1 Full load current Ce r glage est effectu en base de l intensit nominale du moteur I indiqu e sur sa plaque de caract ristique
7. ajustar J es el mismo que el de la intensidad nominal I Ajustar el potenci metro D con el valor de J In e g e g 1 1 5A 1 1 13A HEDEI rie lin 14 11 L A FULL LOAD 05 ON CURRENT LA I gt 5 3 I lt 7 9 FULL LOAD CURRENT U gt 3 11 El rel dispara por sobrecarga a partir de 1 1 por J seg n las curvas de clase 10 1000 100 Fr o Caliente Clase 10 PAE ASUARAN Edif Artxanda nave 23 48950 Asua Erandio Bizkaia ESPA A Tel 34 94 471 14 09 Fax 34 94 471 05 92 E mail fanox fanox com http www fanox com 2 Ajuste del nivel de disparo por subcarga undercurrent x El ajuste del nivel de disparo por subcarga se realiza por medio de un potenci metro 2 en el que se selecciona un factor entre 0 4 y 0 9 Multiplicando este factor por la I ajustada nos da un valor de intensidad por debajo del cual el rel disparar y desconectar el motor Este disparo est retardado 4 segundos a Si la bomba est adecuadamente dimensionada el valor recomendado para este factor es 0 7 Ajustar el potenci metro 2 en 0 7 Esto es aplicable a la mayoria de los casos 05 07 04 0 8 xl 0 9 UNDERCURRENT b Si debido a un excesivo sobredimensionado de la potencia del motor durante el funcionamiento se produjeran disparos intempestivos se reducir el factor de ajuste por subcarga a 0 6 Rearme a Despu s de un disparo por sobr
8. etensi n el rel rearma autom ticamente cuando la tensi n vuelve a tener valores normales g Despu s de un disparo por sobrecarga el rel espera aproximadamente 4 minutos antes de volver a arrancar la bomba autom ticamente A Despu s de un disparo por subintensidad el rel rearma autom ticamente cuando pase el tiempo ajustado mediante el potenci metro 3 PS11 R 2 a 70 minutos PS16 R 2 a 240 minutos mediante el multiplicador 4 Para rearmar el rel de forma manual anular la alimentaci n del cuadro durante 10 segundos aproximadamente por ejemplo desconectando su interruptor magnetot rmico volviendo a restablecer la alimentaci n pasado este tiempo 150 9001 2000 A15026 FANOX se reserva el derecho de efectuar cualquier modificaci n de las caracter sticas se aladas en este documento sin necesidad de previo aviso 6 2008 Settings Depending on the characteristics of the motor and of the installation some simple adjustments must be made to the PS relay Check that the capacitor installed uF corresponds to the one specified by the manufacturer Signalling ON relay in service gt I lt U gt Tripping by overvoltage Tripping due to overload underload lin 14 1 4 I A FULL LOAD ON I gt U gt ON CURRENT I gt 4 Ik I lt 7 9 x3 U gt 3 41 a 06 es 05 0 7 I lt RESET TIME 0 4 0 8 FACTOR Xis 0 9 UNDERCURRENT 15 70 2 I lt
9. r l ajustement du facteur de sous charge doit se r duire jusqu a 0 6 R armement a Apr s un d clenchement par surtension le relais r arme automatiquement quand la tension revient ses param tres normaux b Apr s un d clenchement par surcharge le relais attend approximativement 4 minutes avant de red marrer la pompe automatiquement c Apr s un d clenchement par sousintensit le relais r arme automatiquement quand le temps ajust via potenci m tre 8 est coul PS11 R 2 70 min PS16 R 2 240 min moyen reset time factor a Afin de r armer le relais de fa on manuel annuler l alimentation du coffret en d branchant son interrupteur magn tothermique par exemple pendant 10 seconds approximativement et r tablir l alimentation apr s ce temps ISO 9001 2000 A15026 FANOX se r serve le droit de modifier les caract ristiques indiqu es dans ce document sans pr avis 6 2008
10. s la valeur ajuster I est la m me que celle de l intensit nominale I Ajuster le potentiom tre O avec la valeur I In e g e g 1 1 5A 1 1 13A RESED TIME I D 10 R 13 q N 1 A 14 S FULL LOAD 7 15 0 ON CURRENT 5 16 gt 5 3 I lt 7 LA 9 FULL LOAD CURRENT U gt 3 11 Le relais d clenche par surcharge partir de I selon les courbes clase 10 ts 1000 Frio Caliente Clase 10 PAE ASUARAN Edif Artxanda nave 23 48950 Asua Erandio Bizkaia ESPAGNE Tel 34 94 471 14 09 Fax 34 94 471 05 92 E mail fanox fanox com http Awww fanox com R glage du niveau de d clenchement par sous charge undercurrent x I L ajustement du niveau de d clenchement par sous charge se fait par moyen d un potentiom tre 2 Avec ceci un facteur entre 0 4 et 0 9 doit tre s lectionn En multipliant ce facteur par la J ajust e nous obtenons une valeur d intensit en dessous de laquelle le relais d clenche et arr t le moteur Le d clenchement est retard 4 seconds a Si la pompe est ad quatement dimensionn e la valeur recommand e pour ce facteur est de 0 7 Ajuster le potentiom tre a0 7 Ceci est applicable dans presque la totalit des cas IME 0 5 0 7 i 0 4 0 8 15 xl 0 9 BE UNDERCURRENT b Si pendant le fonctionnement se produisent des d clenchements intempestifs dus a un surdimensionnement excessif de la puissance du moteu
11. tarlo en C y L1 3 Conectar los cables del motor en C CL1 y L1 4 Si no se necesita utilizar los terminales P1 y P2 para un presostato una boya un temporizador etc estos terminales deber n estar puenteados con un cable 5 Conectar la entrada de la red en las bornas del magnetot rmico T KM CONTACTOR REL PS11 R KM INTERRUPTOR Tout MAGNETOT RMICO ENTRADA RED O EE OM L SALIDA BOMBA PRESOSTATO REL PS16 R INTERRUPTOR Cu ee 2 SALIDA BOMBA PRESOSTATO ae Ajustes a realizar En funci n de las caracter sticas del motor y de la instalaci n hay que realizar unos sencillos ajustes en el rel PS Asegurarse de que el condensador instalado uF corresponde con el especificado por el fabricante Se alizaci n ON rel alimentado disparo por sobrecarga subintensidad U gt disparo por sobretensi n lin 14 1 LA FULL LOAD ON I gt U gt ON CURRENT O gt 2 Ix I lt 7 U 9 x3 gt 11 id 0 6 80 min xi 05 07 K me a o4 08 RESET TIME xl 0 9 UNDERCURRENT 45 15 70 I lt RESET TIME min O Ajuste de la intensidad Z Full load current Este ajuste se hace en base a la intensidad nominal del motor I indicada en su placa de caracter sticas el valor a

Download Pdf Manuals

image

Related Search

Related Contents

Car Camera - Kaiser Baas  MCX514 User`s Manual    Mobile Surveillance User Manual  [U4.61.02] Opérateur CALC_VECT_ELEM    c 2014 Sarah Berastegui-Vidalle  