1. GO Wiring of flashing orange light and area lighting m 230V 200W max 8 and 9 230V auxilliary output AREA LIGHTING ORANGE LIGHT 1 2 3 4 5 6 7 8 9 i JUNCTION BOX B Programming 3 1 Microswitches programming FCH CUT THE POWER SUPPLY AFTER EACH NEW PROGRAMMING z fk IN ORDER TO MEMORIZE IT TCA 2P 4P PREALL U P S TW FNV 0 BAR PT iL a Lp poono00on00 Dip 1 and 2 Photocells FCH ON Excludes photocell operation during gate opening and immediately reverses movement during the closing phase when the photocell is obscured OFF In the case where the photocell is obscured by an obstacle during the closing manoeuvre the roller door is stopped when the obstacle is removed the roller door reopens In the case where the photocell is obscured by an obstacle during the opening manoeuvre the roller shutter is stopped when the obstacle is removed it continues to open Dip 3 Impulse blocking IBL ON The Start impulse has no effect d
2. Make bridges between connectors 26 and 28 26 and 30 The earth must be connected 26 and 31 av av a thy gt k thy gt SES Motor direction test THREE PHASES MOTOR p 400V 50Hz S NT a o r fr Ll FF UVW XYZ 12 34 56 Ee SHO To jaa A The earth must be connected I IL ronde C See 5 phase 1 6 phase 2 7 ph 3 BE Remove bridges between connectors 26 and 28 26 and 30 26 and 31 and instead make bridges between 26 28 thermal probe NC 26 30 end limit direction 1 NC 26 31 end limit direction 2 NC 123 4 5 6 7 8 9 Mi M2 MB A R a N Motor direction test fh gt OK dy 4 gt EG 2 4 Connection of control switch 2 4 1 wire command the push button on the cover are delivered wired 26 common 33 open 34 close 26 27 Start NO 26 28 Stop NF 26 33 Open Ouverture NO 26 34 Close Fermeture NO MOTOR THERMAL PROBE a O0 OC Q tal Example of connection with
3. 3 buttons switch r f 1850046 26 27 28 29 30 31 32 33 34 35 36 2 4 2 Radio control 11 and 12 24Vac Power supply 26 commun 27 Start 24 Vac POWER SUPPLY NO 433MHz RECEIVER 2 5 Safety accessories power supply connection SIMU access safety edge power supply ACCESS SAFETY EDGE PHOTO CELLS BARRIER 1 2 3 4 5 6 7 RECEIVER TRANSMITTER 12345 12345 p oaen CE Ci Ci 10 11 12 13 14 15 16 17 18 19 2 6 Safety accessories connection In order to make the drawing easier to understand the power suppy has not been shown 2 5 Wiring 1 safety edge 1 photo cells barrier ACCESS SAFETY EDGE 1 2 3 4 5 6 PHOTO CELLS BARRIER 12345 15 LOOP2 SS 26 COM mB Boe eee eae 29 PHOT 26 27 28 29 30 31 32 33 34 35 36 35 BAR Wiring 1 safety edge 2 photo cells barrier ACCESS SAFETY EDGE PHOTO CELL BARRIER 1 PHOTO CELL BARRIER 2 1 2 3 4 5
4. t contact 3 sur OFF OFF Une impulsion de start donn e pendant que la porte est en mouvement provoque l arr t l impulsion suivante provoque l inversion de la direction de marche logique 4 pas N B L impulsion de start dans la phase d ouverture n a aucun effet avec le contact 3 sur ON 6 Pr alarme PREALL ON La sortie auxiliaire 230Vac s active environ 3 secondes avant le d marrage du moteur OFF La sortie auxiliaire 230Vac s active en m me temps que le d marrage des moteurs 7 Commande Ouvre Ferme U P Agit sur les signaux connect s aux bornes 33 34 ON Fonctionnement action maintenue la manoeuvre continue tant que le bouton de commande reste enfonc OFF Fonctionnement Ouverture Fermeture s par automatique avec une impulsion la porte s ouvre si elle ferm e et vice versa Dip 8 chelle des temps de travail r duite ou normale S TW ON Temps de travail TW compris dans l intervalle 1 90 secondes OFF Temps de travail TW compris dans l intervalle 3 210 secondes Dip 9 Cellules photo lectriques non test es FNV Agit sur la logique de contr le des cellules photo lectriques ON Les cellules photo lectriques sont exclues du cycle de v rification des s curit s effectu avant chaque manoeuvre l tat logique est en tous les cas utilis se r f rer comme connexion la typique fa on de connecter les cellules photo lectriques soit avec faisceau toujours actif Utilis pour co
5. 2 Trimmer set functions TW PED no used i R31 R32 R33 TW Sets the operation time during both the opening and Hf i i O closing phases adjustable from 3 to 210 seconds cee SQ A TCA Sets the dwell time after which the gate closes econ Cl psscsssscce Da 4 automatically from 1 to 120 seconds TWPED TCA TW 3 3 LEDs functions m The SIMUDRIVE 410 control unit is provided with leds which are useful in identifying any anomalies in the system goonoagqagoagqagaoanug HoBebeeees 26 27 28 29 30 31 32 33 34 35 36 lo 2 2 Bm 2 Ooadee TU an MR acarcen HoOBebeees 10 11 12 13 14 15 16 17 18 19 DL1 Stays on when supplied with mains power and with F1 fuse intact DL2 Comes on when the motor is activated during closing DL3 Comes on when the motor is activated during opening DL4 Comes on following the Start command DL5 Goes off when the block command is activated stop by push button or motor thermal probe DL6 Goes off when photocells are not aligned i e when obstacles are present When Dip switch 9 is OFF the photocells and related leds are only activated during manoeuvring DL7 Goes off when the shutter is in the completely open position if provided with end of stroke device DL8 Goes off wh
6. 3 Fonction des LEDS m Le bo tier de commande SIMUDRIVE 410 est dot e d une s rie de led utiles pour l identification d ventuelles anomalies de l installation goonoagqagoagqagaoanug B 0000800080080 lo 2 2 Bm 2 Ooadee TU an DOBSES nE 10 11 12 13 14 15 16 17 18 19 DL1 Reste allum e en pr sence de courant et avec fusible F1 intact DL2 S allume lorsque le moteur est activ en fermeture DL3 S allume lorsque le moteur est activ en ouverture DLA S allume la commande de start bornes 26 27 DLS S allume la commande de blocage stop par bouton poussoir ou moteur en sonde thermique bornes 26 28 DL6 S teint avec les cellules photo lectriques non align es ou en pr sence d obstacles Avec le contact 9 sur OFF les cellules photo lectriques et la led correspondante ne sont activ es que pendant la manoeuvre bornes 26 29 DL7 S teint avec la porte en position d ouverture compl te si dot e de fin de course bornes 26 30 DL8 S teint avec la porte en position de fermeture compl te si dot e de fin de course bornes 26 31 DL9 Non utilis dans le cadre de cette application DL10 S allume la commande manuelle d ouverture bornes 26 33 DL11 S allume la commande manuelle de fermeture bornes 26 34 DL12 S teint lors de l intervention de la barre palpeuse Avec le contact 10 sur OFF la barre palpeuse et la led correspondan
7. 6 7 12345 12345 ay TELELE REA JP2 tT 26 27 28 29 30 31 32 33 34 35 36 35 BAR JPA 10 11 12 13 14 15 16 17 18 19 Wiring 1 safety edge 3 photo cells barrier ACCESS SAFETY EDGE PHOTO CELL BARRIER 1 PHOTO CELL BARRIER 2 PHOTO CELL BARRIER 3 2 3 4 5 6 12345 12345 12345 15 LOOP2 test loop 2 26 COM 29 PHOT 35 BAR Wiring 1 safety edge 4 photo cells barrier 1 26 27 28 29 30 31 32 33 343536 20 21 22 23 24 25 Safety accessories input ACCESS SAFETY EDGE PHOTO CELL BARRIER 1 PHOTO CELL BARRIER2 PHOTO CELL BARRIER 3 PHOTO CELL BARRIER 4 2 3 4 5 6 7 12345 12345 12345 12345 O O O e T O IS iS iO O oO o o o NCC JP4 26 27 28 29 30 31 32 33 34 35 36 00 E 10 11 12 13 14 15 16 17 18 19 JP7 20 21 22 23 24 25 LOOP2 COM PHOT BAR SIMU photo cells barrier power supply
8. FNV 10 BAR 1 et 2 Cellules photo lectriques FCH ON Exclut le fonctionnement de la cellule photo lectrique en ouverture et inverse imm diatement en phase de fermeture en cas d occultation de la cellule photo lectrique OFF Si un obstacle occulte la cellule photo lectrique lorsque la porte est en fermeture celui ci s arr te une fois l obstacle limin La porte s ouvre nouveau Si un obstacle occulte la cellule photo lectrique lorsque la porte est en ouverture celui ci s arr te une fois l obstacle limin la porte continue l ouverture avec installation de s curit haute 3 Blocage des impulsions IBL ON L impulsion de start n a aucun effet dans la phase d ouverture OFF L impulsion de start pendant la phase d ouverture provoque l arr t de la porte 4 Fermeture automatique TCA ON Effectue la fermeture automatique de la porte apr s un temps de pause introduit par le potentiom tre TCA 83 2 La fermeture automatique est activ e par l arriv e de la porte en position de fin de course d ouverture par la fin du temps de travail dans la phase d ouverture ou par l arr t de la porte dans la phase d ouverture au moyen de l impulsion de start OFF Exclut la fermeture automatique 5 Logique 2 ou 4 pas 2P 4P ON Une impulsion de start donn e pendant que la porte est en fermeture provoque l inversion de la direction de marche en ouverture elle en provoque l arr
9. PALPEUSE BARRAGE CELLULES 1 2 3 4 5 6 7 RECEPTEUR EMETTEUR 12345 12345 TJ Bea CE J Ma 12 0 B E 0008000 H 10 11 12 13 14 15 16 17 18 19 10 11 12 13 14 15 16 17 18 19 2 6 C blage des accessoires de s curit pour une meilleure lisibilit des sch mas l alimentation n est pas repr sent e voir 82 5 C blage barre palpeuse 1 barrage cellules RECEPTEUR CELLULE 12345 r n 15 LOOP2 boucle de v rification 2 re j 26 COM DAUABHBDUE 29 pHor 26 27 28 29 30 31 32 33 34 35 36 35 BAR RECEPTEUR BARRAGE 1 RECEPTEUR BARRAGE 2 12345 12345 a l amp lS iS 15 LOOP2 boucle de v rification 2 26 COM 29 PHOT 35 BAR IN NN NN 8 D a NT 1 15 LOOP2 boucle de v rification 2 G Jj 26 COM 29 PHOT ITTI Te 35 BAR PO ABADAAABE 25 21 22 23 24 25 Entr es pour la 57 5 2 28 29 30 31 32 33 34 35 36 connection des accessoires de s curit v rifier 20 21 22 23 24 25 10 11 12 13 14 15 16 17 18 19 C blage barre palpeuse 4 barrages cellules LAME PALPEUSE ACCES RECEPTEUR BARRAGE 1 RECEPTEUR BARRAGE 2 RECEPTE
10. les syst mes de commande appliqu s et sur l ex cution de l ouverture manuelle en cas d urgence Ne pas permettre des personnes et des enfants de stationner dans la zone d action de la motorisation Ne pas laisser de t l commandes ou d autres dispositifs de commande port e des enfants afin d viter des actionnements involontaires de la motorisation l utilisateur doit viter toute tentative d intervention ou de r paration de la motorisation et ne doit s adresser qu du personnel qualifi Tout ce qui n est pas express ment pr vu dans ces instructions est interdit 1 6 B C blage ATTENTION Pour les op rations de c blage et d installation se r f rer aux normes en vigueur et en tous les cas aux principes de bonne technique Les conducteurs aliment s avec des tensions diff rentes doivent tre physiquement s par s ou isol s avec une isolation suppl mentaire d au moins 1mm Les conducteurs doivent tre fix s par une fixation suppl mentaire proximit des bornes par exemple avec des colliers Pour la connexion au r seau lectrique utiliser un c ble multipolaire de section minimale 3x1 5mm2 et du type pr vu par les normes en vigueur A titre d exemple si le cable est l exterieur expos aux intemp ries il doit au moins tre gal HO7RN F tandis qu l interieur ou bien l exterieur dans un canal de protection il doit au moins tre gal HO5 VV F avec
11. 3x1 5mm de section NOTA Avant de connecter l unit de commande au r seau lectrique s assurer que la borne JP5 changement de tension est pr dispos e pour la bonne tension de travail La carte est fournie avec une s rie de bornes connect es en fils volants Les ponts concernent les bornes 26 29 26 30 26 31 26 35 37 38 Si ces bornes ne sont pas utilis es il faut les laisser connect es en fils volants 2 1 Possibilit s de cablage MOTEUR monophas ou triphas BOITE A CLE 200W max UNIVERSELLE ECLAIRAGE DE ZONE FEU CLIGNOTANT ext rieur ANTENNE 433MHz LAME PALPEUSE LLULES PHOTO ELECT BOUTON ROTATIF int rieur 2 2 Alimentation du bo tier le bo tier est fourni en configuration triphas 400V MONOPHASE 230V 50Hz SSS TRIPHASE 400V 50Hz NEUTRE V rifier sur JP5 que le pont se trouve entre 40 et 41 V rifier sur JP5 que le pont se trouve entre 39 et 40 JP5 41 40 39 38 37 41 40 39 38 37 LI LI 2 6 2 3 Connection d un moteur MOTEUR MO
12. 5014016C COFFRET DE COMMANDE SIMUDRIVE 410 Lire attentivement cette notice avant toute utilisation S A S au capital de 5 000 000 Z I Les Giranaux BP71 70103 Arc Les Gray CEDEX RCS GRAY B 425 650 090 SIRET 425 650 090 00011 n T V A CEE FR 87 425 650 090 Lisez attentivement le manuel d instructions qui accompagne le coffret de commande SIMUDRIVE 410 Il fournit d importantes indications concernant la s curit l installation l utilisation et l entretien Ce produit est conforme aux r gles technique et aux dispositions de s curit Nous certifions sa conformit avec les directives europ ennes suivantes 89 336 CEE 73 23 CEE 98 37 CEE et modifications successives en appliquant les r gles techniques suivantes EN60335 1 EN12453 EN12445 Pour les op rations de c blage et d installation se r f rer aux normes en vigueur Toutes les interventions doivent tre effectu es par du personnel qualifi installateur Fi Caract ristiques Techniques Alimentation triphas e 400V avec neutre ou monophas 230V Courant de sortie du moteur max Tri 3A max Mono 5 6A Courant de commande du moteur 8A 12A Puissance max du moteur Pmax Tri 1270W Pmax Mono 1200W Protection par fusibles 10A Alimentation des accessoires 24Vac 0 5A Sortie pour feu orange clignotant et ou feu fixe 230Vac 200W Temp rature de fonctionnement 10 50 C 10T50 Indice de pr
13. NOPHASE 5 sens 1 6 neutre 7 sens 2 230V 50Hz 1 23 4 5 6 7 8 9 230V 50Hz VERT JAUNE GREEN YELLOW D LJA ee A k L BLUE MARRON BROWN NOIR BLACK ANTICHUTE V rifier la pr sence de ponts entre 26 et 28 26 et 30 La terre doit tre raccord e 26 et 31 b ox i 4 gt TE Test du sens de rotation MOTEUR TRIPHASE 400V 50Hz aM Il f T a z A ANTICHUTE La terre doit tre raccord e 5 phase 1 6 phase 2 7 phase 3 Supprimer les ponts entre 26 et 28 26 et 30 26 et 31 et remplacer par 26 28 protection thermique contact NF 26 30 fin de course sens 1 contact NF 26 31 fin de course sens 2 contact NF 123 4 5 6 7 8 9 MI M2 M3 Gy gt Bowe 5 6 7 MI M2 M3 Test du sens de rotation Ex 2 4 Connection des organes de commande 2 4 1 Commandes filaires les deux boutons poussoir en fa ade son
14. OFF TW operation time ranging between 3 and 210 seconds Dip 9 Unchecked photocells FNV Activates the photocell control logic ON The photocells are excluded from the safety check cycle which is carried out before each manoeuvre however their logic state is analysed for connection refer to the typical method of connecting photocells with continuously active beams This is used to connect photocells which have not been checked or have internal self diagnosing systems and always provide a voltage free output contact OFF The photocells are included in the Ok safety check cycle which is carried out before each manoeuvre For connection refer to the enclosed diagrams Dip 10 Unchecked edge BAR Activates the rubber edge device control logic ON The edge devices are excluded from the safety check cycle which is carried out before each manoeuvre however their logic state is analysed for connection refer to the typical method of connecting infrared edges with continuously active beams This is used to connect IR edges which have not been checked or have internal self diagnosing system and always provide a voltage free output contact OFF The IR edge devices are included in the Ok safety check cycle which is carried out before each manoeuvre For connection refer to the enclosed diagrams 5 6 WOONDUBWN 3
15. UR BARRAGE 3 RECEPTEUR BARRAGE 4 2 3 4 5 6 7 12345 12345 12345 12345 O O O T 1 A a A 9 oO 9 OC NCC LOOP2 boucle de v rification 2 26 COM 29 PHOT 35 BAR riba 0800GE 10 11 12 13 14 15 16 17 18 19 JP7 JP4 26 27 28 29 30 31 32 33 34 35 36 20 21 22 23 24 25 CLO i II 4 6 m 230V 200W max 8 et 9 sorties auxilliaires 230V ECLAIRAGE DE ZONE FEU CLIGNOTANT 1 2 3 4 5 6 7 8 9 i C blage du feu clignotant et de l clairage de zone t BOITE DE DERIVATION B Programmation 3 1 Programmation des micro contacts 1 FCH COUPER L ALIMENTATION APRES CHAQUE CHANGEMENT DE 2 FCH PROGRAMMATION AFIN DE MEMORISER CELLE CI E 3 IBL 4 TCA 5 2P 4P 6 PREALL a 7 UP La 8 STW y 9
16. al opening operation in case of emergency Do not allow persons or children to remain in the automation operation area Keep radio control or other control devices out of children s reach in order to avoid unintentional automation activation The user must avoid any attempt to carry out work or repair on the automation system and always request the assistance of qualified personnel Anything which is not expressly provided for in the present instructions is not allowed B Wiring WARNINGS For wiring and installation operations refer to the current standards and good technical principles Wires powered at different voltages must be physically separated or suitably insulated with at least 1 mm extra insulation The wires must be clamped by an extra fastener near the terminals for example by bands For connection to the mains use a multipolar cable with a minimum of 3x1 5mm_ cross section and complying with the previously mentioned regulations For example if the cable is out side in the open it has to be at least equal to HO7RN F but if it is on the inside or outside but placed in a plastic cable cannel it has to be or at least egual to HOSVV F with section 3x1 5mm NOTA Before connecting the control unit to the mains voltage check that the JP5 voltage change terminal is preset for the correct working voltage The board is supplied with a series of previously bridged terminals The jumpers refer to the followi
17. cessories 24Vac 0 5A Orange light and area lighting output 230Vac 200W Working temperature 10 to 50 C 10T50 Protection index IP55 Dimensions 340 x 220 x 130 mm Weight 2 9 Kg ET a General outlines The control panel is used to operate single phase or three phase controllers fitted on rollers doors It is provided with open close buttons A series of LEDs allows to check or detect any operating anomalies in the control unit or on the connected devices The control unit is supplied with Dip switches and Trimmers which provide configuration and calibration respectively Self diagnosis the control unit allows a check to be carried out on operating relays and safety devices photocells safety edge etc before any manoeuvre takes place WARNING An incorrect installation or improper use of the product can cause damage to persons animals or things Scrap packing materials plastic cardboard polystyrene etc according to the provisions set out by current standards Keep nylon or polystyrene bags out of children s reach Keep the instructions together with the technical brochure for future reference This product was exclusively designed and manufactured for the use specified in the present documentation Any other use not specified in this documentation could damage the product and be dangerous The Company declines all responsibility for any consequences resulting from improper u
18. d une utilisation impropre ou diff rente de celle laquelle le produit a t destin et qui est indiqu e dans cette documentation Ne pas installer le produit dans une atmosph re explosive SIMU d cline toute responsabilit en cas de non respect des r gles technique dans la construction des fermetures portes etc l installation doit tre conforme aux prescriptions des Directives Europ ennes 89 336 CEE 73 23 CEE 98 37 CEE et modifications successives Couper l alimentation lectrique avant d effectuer n importe quelle intervention sur l installation D brancher aussi les ventuelles batteries de secours si pr sentes Pour l alimentation de la motorisation pr voir un interrupteur omnipolaire avec distance d ouverture des contacts gale ou sup rieure 3mm L alimentation doit pr senter en amont un interrupteur diff rentiel avec seuil de 0 03A V rifier si l installation de terre est effectu e correctement connecter toutes les parties m talliques de la fermeture portes etc et tous les composants de la motorisation dot s de borne de terre SIMU d cline toute responsabilit en mati re de s curit et de bon fonctionnement de la motorisation si des composants d autres fournisseurs sont utilis s Utiliser exclusivement des pi ces originales pour tout entretien ou r paration Ne pas effectuer de modifications aux composants de la motorisation Informer l utilisateur de l installation sur
19. en the shutter is in the completely closed position if provided with end of stroke device DL9 Not used DL10 Comes on with manual opening command DL11 Comes on with manual closing command DL12 Goes off when the safety edge is activated When Dip switch 10 is OFF the edge and its related LED are only activated during manoeuvring DL13 Comes on when the safety ring is closed self test DL14 Not used 6 6
20. ng terminals 26 29 26 30 26 31 26 35 37 38 If these terminals are not used leave them bridged 2 1 Wiring possibility KEY SWITCH AREA LIGHTING outdoor CT ROTARY SWIT indoor 200W max ORANGE LIGHT Hi Single phase or three phase motor 433MHz RECEIVER SAFETY EDGE PHOTO CELLS BARRIER 2 2 Power supply connection the control box is provided in 400V 3 phases setup SINGLE PHASE 230V 50Hz Check the jumper between 40 and 41 JP5 41 40 39 38 37 LI THREE PHASE 400V 50Hz NEUTRAL Check the jumper between 39 and 40 41 40 39 38 37 LI 2 6 2 3 Motor connection SINGLE PHASE MOTOR 5 direction 1 6 neutral 7 direction 2 230V 50Hz LE 123456783 se ee I HOH Qi ae MARRON SAFETY BRAKE L Brown NOIR BLACK
21. nnecter des cellules photo lectriques non test es ou bien avec autodiagnostic interne et fournissant en tous les cas un contact libre de tension OFF Les cellules photo lectriques sont ins r es dans le cycle de v rification des s curit s Ok effectu avant chaque manoeuvre Pour la connexion se r f rer aux sch mas joints Dip 10 Barre palpeuse non test e BAR Agit sur la logique de contr le du dispositif barre palpeuse ON Les dispositifs barre palpeuse sont exclus du cycle de v rification des s curit s effectu avant chaque manoeuvre Utilis pour connecter des barres palpeuses non v rifi es ou bien avec autodiagnostic interne et fournissant en tous les cas un contact libre de tension OFF Les dispositifs barre palpeuse sont ins r es dans le cycle de v rification des s curit s OK effectu avant chaque manoeuvre Pour la connexion se r f rer aux sch mas joints 3 2 R glage des temps de fonctionnement TW PED Non utilis dans le cadre de cette application o TW R gle le temps de fonctionnement tant en ouverture R31 R32 R33 qu en fermeture A TCA R gle le temps de pause apr s lequel la porte se __ i h referme automatiquement r glable de 1 120 cae TT TT secondes Cl eres or ee TWPED TCA TW 3
22. otection IP55 Dimensions 340 x 220 x 130 mm WA Poids 2 9 Kg ET EB G n ralit s Le coffret de commande peut piloter un moteur monophas ou triphas pour porte enroulable Il dispose de deux boutons poussoirs ouverture femeture Une s rie de leds permet de v rifier ou de localiser les anomalies de fonctionnement de l unit de commande ou des dispositifs annexes L unit de commande est dot e de micro switches et de potentiom tres qui en permettent la configuration et le r glage Auto test l unit de commande permet d effectuer le contr le des relais de marche et des dispositifs de s curit cellules photo lectriques barre palpeuse etc avant d effectuer chaque manoeuvre ATTENTION Une installation erron e ou une utilisation impropre du produit peuvent provoquer des l sions aux personnes et aux animaux ou des dommages mat riel Eliminer les mat riaux d emballage plastique carton polystyr ne etc selon les prescriptions des normes en vigueur Ne pas laisser d enveloppes en nylon et polystyr ne la port e des enfants Conserver les instructions pour les consulter tout moment Ce produit a t con u et r alis exclusivement pour l utilisation indiqu e dans cette documentation Toutes autres utilisations non indiqu es dans cette documentation pourraient provoquer des dommages au produit et repr senter une source de danger pour l utilisateur SIMU d cline toute responsabilit d riv e
23. se of the product or use which is different from that expected and specified in the present documentation Do not install the product in explosive atmosphere The Company declines all responsibility for any consequences resulting from failure to observe Good Technical Practice when constructing closing structures door etc as well as from any deformation which might occur during use The installation must comply with the provisions set out by the following European Directives 89 336 EEC 73 23 EEC 98 37 ECC and subsequent amendments Disconnect the electrical power supply before carrying out any work on the installation Also disconnect any buffer batteries if fitted Fit an omnipolar or magneto thermal switch on the mains power supply having a contact opening distance equal to or greater than 3mm Check that a differential switch with a 0 03A threshold is fitted just before the power supply mains Check that earthing is carried out correctly connect all metal parts for closure doors etc and all system components provided with an earth terminal The Company declines all responsibility with respect to the automation safety and correct operation when other manufacturers components are used Only use original parts for any maintenance or repair operation Do not modify the automation components unless explicitly authorised by the company Instruct the product user about the control systems provided and the manu
24. t pr c bl s 26 commun 33 ouverture 34 fermeture 26 27 Start NO 26 28 Stop NF 26 33 Open Ouverture NO 26 34 Close Fermeture NO OOO 3 13 IS J Exemple de c blage avec bo te 3 boutons r f 1850046 S14 148 S RE i 6 27 28 29 30 31 32 33 34 35 36 3 6 2 4 2 Commande radio 11 et 12 alimentation 24Vac 26 commun ALIMENTATION 24 Vac aa J 27 Start Dl N B RECEPTEUR 433MHz rl Bi Cl Pass Te EEE EEEEEE BZEEEEEEEEEE 26 27 28 29 30 31 32 33 34 35 36 2 5 Alimentation des accessoires de s curit Alimentation de la barre palpeuse SIMU Alimentation d un barrage cellules SIMU LAME
25. te ne sont activ es que pendant la manoeuvre bornes 26 35 DL13 S allume avec la boucle de s curit ferm autotest DL14 Non utilis dans le cadre de cette application 6 6 5014016C GB SIMUDRIVE 410 CONTROL BOX Read carefully these instructions before any use S A S au capital de 5 000 000 Z I Les Giranaux BP71 70103 Arc Les Gray CEDEX RCS GRAY B 425 650 090 SIRET 425 650 090 00011 n T V A CEE FR 87 425 650 090 This product is supplied with an Instruction Manual which should be read carefully as it provides important information about safety installation operation and maintenance This product complies with recognised technical standards and safety regulations This product complies with the recognised technical standards and safety regulations We declare that this product is in conformity with the following European Directives 89 336 EEC and 73 23 EEC 98 37 CEE and subsequent amendments with the following Technical Standards EN60335 1 EN12453 and EN12445 When carrying out wiring and installation work always refer to current standards Any assistance required on automation components must be carried out by a qualified technician installer i Technical specifications Three phases power supply 400 V or single phases 230 V Motor output current 2A 4A Motor output comm current 3A 5 6A Maximum motor power 1270W 1200W Fuses 10A Power supply to ac
26. uring the opening phase OFF The Start impulse during the opening phase causes the gate to stop Dip 4 Automatic closing TCA ON Automatically closes the shutter after a dwell time set by the TCA trimmer The automatic closing manoeuvre is activated after the gate has reached the opening end of stroke position after the gate opening time has ended or after the shutter has stopped in the opening phase due to a Start impulse OFF Excludes automatic closing Dip 5 2 or 4 step logic 2P 4P ON A Start impulse given during the closing phase reverses the direction of movement during the opening phase it stops the gate Dip switch OFF OFF A Start impulse given while the gate is moving causes it to stop the following impulse reverses the running direction 4 step logic N B The Start impulse in the opening phase has no effect when Dip switch 3 is ON Dip 6 Pre alarm PREALL ON The blinker comes on about 3 seconds before the motor starts OFF The blinker comes on at the same time as the motor starts Dip 7 Open Close command U P Activates the signals connected to terminals 33 34 ON Hold to run operation the manoeuvre continues as long as pressure is maintained on the command button OFF Separate automatic Open Close operation by means of an impulse it opens the gate if closed and vice versa Dip 8 Reduced or normal operation time range S TW ON TW operation time ranging between 1 and 90 seconds