Home
Manuel d`instructions Instruction Manual
Contents
1. This version replaces all previous versions al Dental Direkt GmbH Industriezentrum 106 108 32139 Spenge Germany Tel 0049 5225 863190 2 2 Manuel d instructions Instruction Manual _ DD cubeX _Rev 01_ docx 0482
2. sssss Dental mau jrekt materials DD cubeX2 HE subie zirena fr ceramics of type ll class 5 acc to1S0 6872 E E Manuel d instructions DDcubeX Propri t s sp cifiques du mat riel Composition chimique Gew ZrO HfO gt Y203 Al203 Autres oxydes Propri t s physiques Densit apr s frittage g cm CDT 25 500 C 10 K R sistance la fracture MPavm R sistance la flexion MPa E Module GPa Explication des symboles il Fabricant al Date de fabrication Lii Consulter les instructions z tiliser avant C r O Num ro de lot Num ro d article Stocker au sec 2 gt 90 lt 10 lt 0 1 lt 0 005 gt 6 0 10 4 8 gt 720 210 AILA i S Instruction Manual DDcube X Material related characteristics Chemical Composition wt ZrO HfO Y203 Al203 Other oxides Physical specifications Density after sintering g cm CTE 25 500 C 10 K Fracture toughness MPaVm Flexural strength MPa E modulus GPa Explanation of symbols sl Manufacturer wl Date of manufacture Li Consult instructions for use z Use by LOT Batch code Catalogue No nl nl Vi Store dry 2 gt 90 lt 10 lt 0 1 lt 0 005 gt 6 0 10 4 8 gt 720 210 al Dental Direkt GmbH Industriezentrum 106 108 32139 Spenge Germany Tel 0049 5225 863190 Manuel d instructions Instruc
3. be taken into account The frameworks need to be examined for visible defects Do not process damaged or contaminated frameworks Please pay attention to our separate sintering instruction Sintering cycle for normal furnace filling without cover Heating up to 900 C 1652 F with 8 C min 46 F min dwell at 900 C 1652 F for 30 minutes heating up to final temp 1450 C 2642 F with 3 C min 37 F min dwell at final sintering temperature 1450 C 2642 F for 120 min cooling to 200 C 392 F with 10 C min 50 F min 1 Avoid additional mechanical actions after sintering like blasting or grinding If corrections are inevitable use water cooled diamond tools for the conditioning and make sure that there is no development of heat which could lead to cracks in the material Please work only with sharp diamond coated tools and very slight contact pressure Areas that are under tension in clinical use e g connectors must not be processed Do not separate in interdental regions Avoid sharp edges 7 Mounting For anchoring we recommend conventional cementation with zinc oxide phosphates cements or glasionomer cements Also luting composites may be used Sufficient retentions and a stump with height of at least 3 mm are essential We reserve the right to make changes as a result of the continuous development of our products Please find the current version of the instruction manual on our website www dentaldirekt de
4. de chaleur qui pourrait produire des fissures dans le mat riel Travaillez uniquement avec des outils coupants recouverts de diamant et avec peu de pression Les zones sous tension en utilisation clinique p ex connecteurs ne doivent pas tre modifi s Evitez les angles vifs 7 Scellement Nous recommandons un scellement conventionnel l oxyphosphate de zinc ou un ciment de verre ionom re Les composites de scellement peuvent tre utilis s Une r tention suffisante et une hauteur de pr paration minimale de 3mm sont essentiels Nos produits font l objet d un d veloppement continu Nous nous r servons donc le droit d effectuer des modifications dans la manipulation ou la composition Vous trouverez la version actuelle respective des instructions de traitement Sous www dentaldirekt de Cette version remplace toutes les versions ant rieures NILA Sta Instruction Manual 1 Indications High translucent zirconia for the manufacture of monolithic or for ceramic veneering reduced partial or single crowns bridges with up to 3 elements anterior and posterior region inlays onlays and veneers for dental application 2 Contraindications Para functional habits e g bruxism insufficient space inadequate preparation known intolerance to the contained components insufficient oral hygiene 3 Safety information Please pay attention to the information in the instruction manual in its current version Avoid
5. the inhalation of dust particles during processing Wear protection gloves safety glasses and a dust mask to prevent irritations of eyes skin and respiratory system 4 Handling and storage Verify the integrity of the packaging and the blank itself before the first processing Check if the content of the packaging corresponds to the declaration given on the label Do not use damaged material Storage only in the original containers in a cool and dry environment Avoid vibrations contaminations and contact with fluids 5 Processing Designing Handling this medical device should only be allowed to trained staff Following construction parameters need to be considered Connector cross EEEE mm Singecrown X 04 _ Telescope X o5 f o Bridge 3 elements Anterior 0 5 210 Posterior 0 5 213 Legend X abutment tooth O pontic Please note Depending on the construction the connector cross section might need to be of larger dimensions An oval connector cross section is desirable the height of the connector is the decisive factor Frameworks for ceramic veneering need to be designed in a way to support the veneering ceramic in the cusp region and allow a constant layer thickness Shoulder or chamfer preparation is recommended 6 Milling sintering and further processing Machining of blanks should always be conducted in the corresponding milling system All information given by the manufacturer of the machine shall
6. es param tres suivants doivent tre pris en consid ration Epaisseur de parois Section de E connecteur E Couronne m e i CE Pont de 3 l ments Ant rieur 0 5 210 Post rieur 0 5 gt 13 L gende X Pilier O Pontique Pour les connecteurs on doit rechercher la plus grande section ovale possible La hauteur du connecteur est un facteur d cisif La conception du modelage doit soutenir la c ramique de recouvrement dans la zone des cuspides et permettre l application d une couche homoth tique Les pr parations en paulement ou chanfrein sont recommand es 6 Fraisage frittage et traitements ult rieurs L usinage des disques doit toujours tre r alis dans une usineuse compatible Toutes les informations donn es par le fabricant de la machine doivent tre respect es Un examen visuel des armatures doit d tecter les d fauts visibles N utilisez pas d armatures endommag es ou contamin es Observez svp nos recommandations de frittage s par es Cycles de frittages pour fours normaux sans couvercle Chauffe jusqu 900 C 8 C min 30 min de maintien 900 C Chauffe jusqu temp rature finale 1450 C 3 C min 120 min de maintien 1450 C Refroidissement jusqu 200 C 10 C min Evitez un travail ult rieur au frittage tel que sablage ou meulage Si des corrections sont in vitables utilisez des outils diamant s refroidis l eau et soyez certain de ne pas produire
7. tion Manual_DD cubeX _Rev 01_ docx 1 2 0482 mL Dental mau jrekt materials DD cubeX2 HE subie zirconia system ceranmics oftype class 5 acc to1S0 6872 L 1 Indications Oxyde de zircone hautement translucide pour la fabrication de couronnes anatomiques ou r duites pour application c ramique de ponts jusqu 3 l ments dans le secteur ant rieur ou lat ral d inlays onlays ainsi que de facettes Manuel d instructions 2 Contre indications Parafonctions par ex bruxisme place insuffisante pr paration inadapt e intol rance connue des composants hygi ne buccale insuffisante 3 Informations relatives la s curit Veuillez lire toutes les informations qui figurent dans la version actuelle de ce mode d emploi Evitez l inhalation de la poussi re de fraisage et de polissage durant le travail Portez des lunettes de protection et un masque de protection contre les poussi res 4 Manipulation et stockage Veuillez v rifier l int grit de l emballage et du disque lui m me avant la premi re utilisation Contr lez que le contenu corresponde l tiquette N endommagez pas le mat riel Les disques doivent tre stock s dans leur emballage d origine dans un environnement frais et sec Evitez les vibrations contaminations et contacts avec les fluides 5 Travail Construction La manipulation de ce produit doit s effectuer uniquement par du personnel form L
Download Pdf Manuals
Related Search
Related Contents
MANUALE D`INSTALLAZIONE ED USO User`s Manual (EN) - Avitech International Corporation Entire Dayton Die Cushions Catalog Aquatic AI6032DHS User's Manual Shooting in Sh*tty Light: The Top Ten Worst Herunterladen - Canon Europe Bayer CropScience Hoja de Seguridad para Materiales de acuerdo Información técnica Copyright © All rights reserved.