Home

INSTALLATION INSTRUCTIONS

image

Contents

1. The DrawerMicro Oven can be installed below any electric or gas wall Oven Can also be installed using an electrical outlet in an adjacent cabinet within the area where the provided electrical cord can reach Power cord access hole in cabinet should be a minimum 1 diameter hole and deburred of all sharp edges Always allow sufficient power cord length to the electrical outlet to prevent tension DO NOT USE AN EXTENSION CORD Always check electrical codes for requirements ANTI TIP BLOCK NORMAL INSTALLATION STEPS ANTI TIP BLOCK INSTALLATION INSTRUCTIONS To reduce the risk of tipping of the drawer the Anti Tip block must be properly installed located 14 16 above the floor on which the appliance will sit The 6 Anti Tip block must be provided by the installer See FIGURE 1 The Anti Tip block prevents serious injury that might result from spilled hot liquids If the DrawerMicro Oven is ever moved to a different ocation the Anti Tip block must also be moved and installed When installed to the wall make sure that the screws completely penetrate the dry wall and are secured in wood or metal so that the block is totally stable When fastening be sure that the screws do not penetrate electrical wiring or plumbing ELECTRICAL OUTLET The electrical requirements are a 120 volt 60 Hz AC only 15 amp or more protected electrical supply It is recommended that a separate circuit serving only this appliance be provide
2. lectrique ADVERTISSEMENT Un mauvais usage de la fiche de mise la terre peut entra ner un risque de d charge lectrique N utilisez pas de rallonge BONNE INSTALLATION PERMANENTE Prise de courant trois bornes Fiche trois broches Bo te de prise mise la terre ENTRETIEN NETTOYAGE ET SERVICE Consultez le manuel d utilisateur pour des instructions sur le nettoyage VIKING RANGE CORPORATION 111 Front Street Greenwood Mississippi 38930 USA 662 455 1200 F4 EMPLACEMENT DES NUM ROS DE MOD LE ET DE S RIE ____ La plaque d identit incluant les num ros de mod le et de s rie se trouve sur l arri re de la face avant du Four DrawerMicro AVANT D APPELER UN TECHNICIEN Lisez les sections AVANT D APPELER UN TECHNICIEN et Instructions d op ration dans le manuel d utilisateur a pourrait viter des pertes de temps et des d penses futiles La liste inclut des v nements communs qui ne r sultent pas de d fectuosit s de l appareil Consultez la garantie dans votre manuel d utilisateur pour trouver le num ro de service sans frais et les coordonn es pertinentes de Viking Veuillez nous t l phoner ou nous crire si vous avez des questions propos de votre appareil micro ondes ou si vous d sirez en acheter des pi ces TINSKB113MRRO
3. Posez le tiroir contre l ouverture dans le mur ou dans le placard Branchez la fiche dans la prise murale 2 Glissez soigneusement le tiroir dans l ouverture pr par e Evitez de pincer le cordon entre le four et le mur 3 Glissez compl tement le tiroir jusqu ce que l aile de fixation soit affleur e avec la face du placard Consultez la FIGURE 5A 4 Ouvrez le tiroir Utilisez comme gabarit les 4 trous dans le tiroir et percez 4 trous dans le mur avec un mors 16 po Consultez la FIGURE 5A 5 Fixez le tiroir l aide des 4 vis fournies Consultez la FIGURE 5B soit compl tement stable En outre assurez vous que les vis n entrent pas en contact avec du fil lectrique ou avec de la plomberie 6 po 153 mm gt Bloc antibasculement FIGURE 3 Emplacement de la prise de courant TS A em ls po Ts 127 mm 4 po 101 6 mm FIGURE 4 FIGURE 5A FIGURE 5B INSTRUCTIONS POUR LA MISE A LA TERRE Il faut que cet appareil soit mis la terre Le Four DrawerMicro est quip d un cordon avec un conducteur de terre et une fiche de mise la terre Il faut brancher cette derni re sur une prise murale d ment install e et mise la terre selon le Code National d lectricit et selon les codes et r glements locaux En cas de court circuit la mise la terre r duit le risque de d charge lectrique en fournissant une voie d chappement pour le courant
4. l heure s affiche Sinon appuyez sur Stop Clear pour pr venir un emploi non autoris e V rifiez l existence d un secteur d alimentation suffisant o le Four DrawerMicro sera install e Votre four peut tre encastr seul dans un placard dans un mur ou bien au dessous d un four mural lectrique ou gaz e Assurez vous que le jeu entre le dessous du four mural et le dessus du Four DrawerMicro est d un minimum de 2 pouces e La cavit du four micro ondes acceptera facilement un plat oblong de 9 po x 13 po ou un sac de ma s souffl pour micro ondes 4 A ei 21 1 2 po 1 2 po AS Glissement automatique de tiroir 1 po 3 po a Epaisseur de es porte 1 1e po FIGURE 2 Les tiroirs micro ondes peuvent s installer en dessous de tout four mural lectrique ou gaz Peut galement tre install en utilisant une prise murale dans un placard adjacent pourvu que le cordon d alimentation atteigne facilement la prise Le trou d acc s du cordon d alimentation dans le placard devrait avoir un diam tre de 1 po minimum et devrait tre compl tement barb de surfaces pointues LIEU Pr venir toujours un jeu suffisant dans le cordon d alimentation pour viter que celui ci ne soit tendu N UTILISEZ PAS DE RALLONGE V rifier toujours le code lectrique de votre municipalit pour les exigences particuli res BLOC ANTI BASCULEMENT TAPES D INSTALLATION HABITUELLES I
5. LCADURAS Para reducir el riesgo de volcadura de la gaveta el bloque antivolcaduras debe ser instalado correctamente a una distancia de 14 16 por encima de la superficie en la cual se apoyara el Horno DrawerMicro El bloque antivolcaduras de 6 debe ser suministrado por el instalador Vea la FIGURA 1 El bloque antivolcaduras previene lesiones graves que podrian ser ocasionadas por derrames de liquidos calientes Si el Horno DrawerMicro es traslado alguna vez a otra ubicaci n el bloque antivolcaduras tambi n deber ser trasladado e instalado Al instalarla en la pared asegurese TOMACORRIENTE ELECTRICO Los requisitos el ctricos son 120 voltios 60 Hz s lo CA 15 amperios o mas de suministro protegido de electricidad Se recomienda un circuito por separado que sea s lo para este electrodom stico El Horno DrawerMicro esta equipado con un enchufe con toma a tierra de tres clavijas Se debe conectar en un tomacorriente de pared instalado y conectado a tierra apropiadamente Si solo cuenta con un tomacorriente de dos clavijas haga que un electricista calificado instale un tomacorriente de pared correcto Nota Si tiene alguna pregunta sobre las instrucciones el ctricas o de conexi n a tierra consulte a un electricista calificado o al encargado de brindar el servicio INSTALACI N DE LA GAVETA 1 Coloque el Horno DrawerMicro al lado de la abertura de la pared o gabinete Conecte el cord n de alimentaci n al tomacorrient
6. NDIQU S AUX PAGES 2 CONSULTEZ REMARQUES IMPORTANTES POUR LE CONSOMMATEUR ____ Conservez ce manuel avec votre manuel d utilisateur pour r f rence ult rieure e Comme c est le cas pour tout four micro ondes qui produit de la chaleur il faut suivre certaines consignes de s curit Ces consignes sont signal es dans le manuel d utilisateur Veuillez les lire le les suivre de pr s e Assurez vous que le Four DrawerMicro est install et mis la terre par un installateur ou un technicien qualifi INSTRUCTIONS DE SURETE IMPORTANTES ADVERTISSEMENT Si l on ne suit pas de pr s les indications dans ce manuel il y a un risque d incendie ou de d charge lectrique qui pourrait provoquer des dommages des biens des blessures personnelles voire la mort ADVERTISSEMENT Pour r duire le risque de basculement il faut fixer le Four DrawerMicro avec un bloc antibasculement correctement install e Ce Four DrawerMicro doit tre mis la terre conform ment aux codes locaux e Assurez vous que les rev tements muraux et les placards autour du Four DrawerMicro sont faits pour supporter la chaleur produite par le lectrom nager ADVERTISSEMENT Ne laissez jamais les enfants seuls ou sans supervision aux alentours du Four DrawerMicro lorsque ce dernier fonctionne Ne laissez jamais ouvert le tiroir sans supervision ADVERTISSEMENT Le fait de marcher de s appuyer ou de s asseoir sur le tiroir peut provoq
7. NSTRUCTIONS POUR L INSTALLATION DU BLOC ANTIBASCULEMENT Pour r duire le risque de basculement du tiroir il faut installer le bloc antibasculement conform ment aux indications 14 16 pouces au dessus du sol sur lequel le lectrom nager sera pos Le bloc antibasculement six pouces doit tre fourni par l installateur Consultez les FIGURE 1 Le bloc antibasculement pr vient des blessures s rieuses ventuelles dues au d versement de liquides chauds Si jamais l on choisit de changer l emplacement du Four DrawerMicro il faut changer l emplacement du r installer le bloc antibasculement en m me temps En fixant le bloc antibasculement au mur assurez vous que les vis p n trent compl tement dans la cloison s che et qu elles s enfoncent dans du bois ou du m tal de sorte que le bloc PRISE LECTRIQUE La tension requise est un secteur d alimentation lectrique prot g 120 volt 60 Hz CA seulement 15 amp ou plus Il est recommand de pr voir un circuit s par pour cet appareil Le tiroir est quip d une fiche de mise la terre trois fiches Il faut la brancher sur une prise murale d ment install e et mise la terre Si vous n avez qu une prise 2 fiches demandez un lectricien qualifi d installer une prise convenable Remarque Pour toute question au sujet de la mise la terre ou des connexions lectriques consultez un lectricien ou un technicien qualifi INSTALLATION DU TIROIR 1
8. National Electrical Code and local codes and ordinances In the event of an electrical short circuit grounding reduces risk of electric shock by providing an escape wire for the electric current WARNING PERMANENT AND CORRECT INSTALLATION Improper use of the grounding 3 Prong Plug Pang plug can result in ceo Receptacle a risk of electric shock Do not SS Ground useanextension Grounding Pin Receptacle Box cord CARE CLEANING AND MAINTENANCE Refer to the Use and Care Manual for cleaning instructions VIKING RANGE CORPORATION 111 Front Street Greenwood Mississippi 38930 USA 662 455 1200 E4 MODEL AND SERIAL NUMBER LOCATION The name plate including model and serial number is located on the faceplate behind the drawer front BEFORE YOU CALL FOR SERVICE Read the BEFORE YOU CALL and operating instruction sections in your Use and Care Manual It may save you time and expense The list includes common occurrences that are not the result of defective workmanship or materials in this range Refer to the warranty in your Use and Care Manual for Viking s toll free service number and address Please call or write if you have inquiries about your microwave product and or need to order parts TINSKB113MRRO VIKING Horno DrawerMicro INSTRUCCIONES DE INSTALACION IMPORTANTE LEA Y SIGA LAS INSTRUCCIONES e LA INSTALACI N Y EL SERVICIO DEBEN SER REALIZADOS POR UN INSTALADOR CALIFICADO
9. VIKING DrawerMicro Oven INSTALLATION INSTRUCTIONS IMPORTANT PLEASE READ AND FOLLOW e INSTALLATION AND SERVICE MUST BE PERFORMED BY A QUALIFIED INSTALLER e THE INSTALLER SHOULD LEAVE THESE INSTRUCTIONS WITH THE CONSUMER WHO SHOULD RETAIN FOR LOCAL INSPECTOR S USE AND FOR FUTURE REFERENCE e FOR SAFETY CONSIDERATIONS DO NOT INSTALL DRAWER IN ANY COMBUSTIBLE CABINETRY WHICH IS NOT IN ACCORD WITH THE STATED CLEARANCES AND DIMENSIONS ON PAGE 2 SEE FIGURE 1 UNPACKING YOUR DrawerMicro Oven Remove all packing materials from inside the DrawerMicro Oven DO NOT REMOVE THE WAVEGUIDE COVER which is located on the top of the appliance Sealing Surface N Waveguide Cover Oven Cavity Remove the feature sticker if there is one Check the drawer for any damage such as misaligned or bent drawer damaged drawer seals and sealing surfaces broken or loose drawer guides and dents inside the cavity or on the front side of the drawer If there is any damage do not operate the appliance and contact your dealer or a VIKING AUTHORIZED SERVICER IMPORTANT NOTES TO THE INSTALLER e Read all of the Installation Manual before installing the DrawerMicro Oven e Remove all packing material before connecting the electrical supply e Observe all governing codes and ordinances e Besure to leave these instructions with the consumer IMPORTANT NOTES TO THE CONSUMER Keep this manual with your Use and Care M
10. VRE LECTRIQUE LOCAL LES FIGURE 1 D BALLAGE DU Four DrawerMicro Retirez tout le mat riau d emballage du DrawerMicroOven N ENLEVEZ PAS LE COUVERCLE DU GUIDE D ONDES qui se trouve sur le dessus du Four DrawerMicro Surface d tanch it Couvercle du guide d ondes Cavit du four Enlevez l autocollant descriptif s il y en a un Inspectez le tiroir pour toute sorte de dommage dont un tiroir d cal ou tordu des sceaux d tanch it endommag s sur le tiroir ou sur le plafond du tiroir des glissi res cass es ou laches ou des enfoncements dans la cavit ou sur la face du tiroir Si vous trouvez des dommages n utilisez pas le Four DrawerMicro contactez votre revendeur ou votre AGENT DE SERVICE AGR VIKING REMARQUES IMPORTANTES POUR L INSTALLATEUR e Lisez tout le manuel d installation avant d installer le Four DrawerMicro e Enlevez tout le mat riau d emballage avant de connecter le secteur d alimentation lectrique e Observez tous les codes et r glements principaux e Assurez vous de laisser ces instructions avec le consommateur F1 e L INSTALLATION ET LE SERVICE DOIVENT TRE EFFECTU S PAR UN TECHNICIEN QUALIFI e CONSERVEZ CE MANUEL D INSTALLATION POUR CONSULTATION ULT RIEURE PAR VOTRE INSPECTEUR DE SERVICE e POUR DES RAISONS DE S CURIT N INSTALLEZ CE TIROIR DANS AUCUN GENRE DE PLACARD COMBUSTIBLE NI AUCUN PLACARD QUI NE SE CONFORME PAS AUX DIMENSIONS ET ESPACES I
11. anual for future reference e As when using any microwave oven generating heat there are certain safety precautions you should follow These are listed in the Use and Care Manual Read all and follow carefully e Be sure your DrawerMicro Oven is installed and grounded properly by a qualified installer or service technician IMPORTANT SAFETY INSTRUCTIONS WARNING If the information in this manual is not followed exactly a fire or electrical shock may result that could cause property damage personal injury or death WARNING To reduce the risk of tipping the DrawerMicro Oven must be secured by a properly installed Anti Tip block e This appliance must be electrically grounded in accordance with local codes e Make sure the wall coverings and the cabinets around the DrawerMicro Oven can withstand the heat generated by the appliance WARNING Never leave children alone or unattended in the area where a appliance is in use Never leave the drawer open when the microwave is unattended WARNING Stepping leaning or sitting on the drawer may result in serious injuries and can also cause damage to the appliance e Do not use the DrawerMicro Oven as a storage space This creates a potentially hazardous situation e Check that the time of day is in the display If not touch Stop Clear to prevent unintended use CLEARANCES AND DIMENSIONS Dimensions that are shown in FIGURE 1 must be used Given dimensions provide minimum c
12. cionando una v a de escape para la corriente el ctrica ADVERTENCIA El uso inapropiado del enchufe con conexi n a tierra puede resultar en riesgo de descarga el ctrica INSTALACI N PERMANENTE Y CORRECTA Enchufe de 3 clavijas CIS Caja del tomacorriente a tierra Tomacorriente para 3 clavijas a Clavija de tierra No use un cable de extension VIKING RANGE CORPORATION 111 Front Street Greenwood Mississippi 38930 EE UU 662 455 1200 S4 CUIDADO LIMPIEZA Y MANTENIMIENTO Consulte el Manual de uso y cuidado para ver las instrucciones de limpieza UBICACI N DEL MODELO Y N MERO DE SERIE La placa de identificaci n que incluye el modelo y el n mero de serie est ubicado en la placa frontal detr s de la parte frontal del Horno DrawerMicro ANTES DE LLAMAR PARA SOLICITAR SERVICIO Lea las secciones ANTES DE LLAMAR y de instrucci n de operaci n de su Manual de uso y cuidado Esto le ahorrar tiempo y gastos La lista incluye ocurrencias comunes que no son resultado de mano de obra o materiales defectuosos en este horno Consulte la garant a en su Manual de uso y cuidado para obtener el n mero de tel fono gratuito y direcci n de servicio de Viking Por favor ll menos o escr banos si tiene dudas acerca de su producto de microondas y o si necesita ordenar partes TINSKB113MRRO VIKING Four DrawerMicro MANUEL D INSTALLATION IMPORTANT S IL VOUS PLA T LIRE ET SUI
13. d The appliance is equipped with a 3 prong grounding plug It must be plugged into a wall receptacle that is properly installed and grounded Should you only have a 2 prong outlet have a qualified electrician install a correct wall receptacle Note If you have any questions about the grounding or electrical instructions consult a qualified electrician or service person DRAWER INSTALLATION 1 Place the DrawerMicro Oven adjacent to the wall or cabinet opening Plug the power supply cord into the electrical outlet 2 Carefully guide the appliance into the prepared opening Avoid pinching the cord between the oven and the wall 3 Slide the drawer all the way until the mounting flange is flush with the face of the cabinet See FIGURE 5A 4 Open the drawer Using the 4 holes on the drawer as a template pre drill the cabinet using a 16 bit See FIGURE 5A 5 Secure the drawer with the 4 screws supplied See FIGURE 5B E3 er 153 mm gt m Anti tip Block FIGURE 3 Electrical Outlet Location D De El NS fs a 127 mm y Eq 101 6 mm FIGURE 4 Mounting Flange FIGURE 5A FIGURE 5B GROUNDING INSTRUCTIONS This appliance must be grounded The DrawerMicro Oven is equipped with a cord having a grounding wire with a grounding plug It must be plugged into a wall receptacle that is properly installed and grounded in accordance with the
14. e EL INSTALADOR DEBE DEVOLVER ESTAS INSTRUCCIONES AL CLIENTE QUIEN DEBE CONSERVARLAS PARA USO DEL INSPECTOR LOCAL Y PARA REFERENCIAS FUTURAS e POR CUESTIONES DE SEGURIDAD NO INSTALE LA GAVETA EN ARMARIOS INFLAMABLES QUE NO CUMPLAN CON LOS ESPACIOS LIBRES Y DIMENSIONES ESTABLECIDOS EN LA P GINA 2 VEA LA FIGURA 1 DESEMBALAJE DE SU Horno DrawerMicro Retire todos los materiales de embalaje que est n dentro de la gaveta NO RETIRE LA CUBIERTA DE LA GU A DE ONDAS ubicada en la parte superior del Horno DrawerMicro Superficie de sellado N Cubierta de la guia de ondas __ Cavidad del horno Si hay una etiqueta adhesiva retirela Verifique que la gaveta no tenga da os como que est torcida o mal alineada sellos de la gaveta y superficies de sellado da ados guias del Horno DrawerMicro rotas o flojas y abolladuras dentro de la cavidad o en la parte frontal de la gaveta Si encuentra alg n da o no opere el electrodom stico y comuniquese con su distribuidor o PERSONAL DE SERVICIO AUTORIZADO DE VIKING NOTAS IMPORTANTES PARA EL INSTALADOR e Lea por completo el Manual de instalaci n antes de instalar el Horno DrawerMicro e Retire todos los materiales de embalaje antes de conectar el suministro de energia el ctrica e Cumpla con todos los c digos y normas vigentes e Aseg rese de entregar estas instrucciones al consumidor S1 NOTAS IMPORTANTES PARA EL CONSUMIDOR Conserve este manua
15. e el ctrico 2 Gu e con cuidado el electrodom stico dentro de la abertura preparada Evite que el cable quede apretado entre el horno y la pared 3 Deslice la gaveta completamente hasta que la brida de montaje est nivelada con la parte frontal del gabinete Vea la FIGURA 5A 4 Abra la gaveta Usando los 4 agujeros en la gaveta como plantilla pre taladre el gabinete con una broca de 1 16 Vea la FIGURA 5A 5 Asegure la gaveta con los 4 tornillos suministrados Vea la FIGURA 5B de que los tornillos penetren por completo en el drywall y se aseguren en madera o metal de modo que el bloque se encuentre totalmente estable Al ajustar los tornillos aseg rese que no perforen el cableado el ctrico o las instalaciones sanitarias le 6 153 mm gt Bloque antivolcaduras FIGURA 3 Ubicaci n del tomacorriente el ctrico 4 101 6 mm FIGURA 4 FIGURA 5A FIGURA 5B 4 Tornillos INSTRUCCIONES DE CONEXION A TIERRA Este electrodom stico debe ser conectado a tierra El Horno DrawerMicro esta equipado con un cable que tiene un alambre de tierra y un enchufe con toma a tierra Este se debe conectar en un tomacorriente de pared instalado y conectado a tierra apropiadamente de acuerdo con el C digo El ctrico Nacional y los c digos y reglamentos locales En caso que se produzca un cortocircuito el ctrico la conexi n a tierra reduce el riesgo de descarga el ctrica propor
16. gavetas S2 FIGURA 2 23 Verifique la ubicaci n donde sera instalada la gaveta para que cuente con el suministro de electricidad apropiado Su Horno DrawerMicro puede ser empotrado en un gabinete o pared individualmente o debajo de un horno a gas o el ctrico de pared Aseg rese de que el espacio libre de la superficie o piso entre el horno de pared y del electrodom stico sea como minimo de 2 El interior del microondas tiene la capacidad de alojar facilmente un recipiente rectangular de 9 x 13 o una bolsa de palomitas de maiz para microondas gt wE 21 1 ite T l 14 19 Abertura de gaveta autom tica 15 23 1 gt Espesor de la nu 2 puerta de 1 3 4 El Horno DrawerMicro puede ser instalado debajo de un horno a gas o el ctrico de pared x Tambi n puede ser instalado usando un tomacorriente el ctrico en un gabinete adyacente dentro del area de alcance del cable el ctrico suministrado El orificio de acceso del cable de alimentaci n debe ser de un m nimo de 1 de di metro y libre de bordes speros Siempre deje una longitud suficiente de cable de alimentaci n hasta el tomacorriente el ctrico para prevenir la tensi n del cable NO USE UN CABLE DE EXTENSI N Siempre verifique los c digos el ctricos para ver los requisitos BLOQUE ANTIVOLCADURAS PROCEDIMIENTO NORMAL DE INSTALACION INSTRUCCIONES DE INSTALACION DEL BLOQUE ANTIVO
17. l junto a su Manual de uso y cuidado para referencia futura e Tal como cuando utiliza cualquier horno microondas que genera calor existen ciertas precauciones de seguridad que se deben tomar en cuenta stas se encuentran en el Manual de uso y cuidado Lea todas las precauciones y s galas cuidadosamente e Aseg rese que su Horno DrawerMicro sea instalado y conectado a tierra correctamente por un instalador o t cnico de servicio calificado INSTRUCCIONES DE SEGURIDAD IMPORTANTES ADVERTENCIA Si no se cumple con la informaci n contenida en este manual con exactitud es posible que ocurra un incendio o descarga el ctrica que podr a causar da o a la propiedad lesiones personales o la muerte ADVERTENCIA Para reducir el riesgo de volcaduras el Horno DrawerMicro debe estar asegurado con un bloque antivolcaduras correctamente instalado e Esta gaveta debe contar con conexi n el ctrica a tierra de acuerdo con los c digos locales e Aseg rese que todos los revestimientos de pared y los gabinetes alrededor del Horno DrawerMicro puedan soportar el calor generado por el artefacto ADVERTENCIA Nunca deje a los ni os solos o sin supervisi n en el rea donde un electrodom stico se encuentre en uso Nunca deje la gaveta abierta cuando el microondas est sin supervisi n ADVERTENCIA Pararse apoyarse o sentarse en la gaveta puede ocasionar lesiones graves y tambi n causar da o al Horno DrawerMicro e No use el Horn
18. learance Locate electrical outlet in the shaded area in the upper left hand corner of the cutout See FIGURE 4 Contact surface must be solid and level Pay special attention to the floor on which the appliance will sit The floor of the opening should be constructed of plywood strong enough to support the weight of the oven about 100 pounds DrawerMicro Oven MEASUREMENTS Electrical outlet location Anti Ti plock 3 Ho 14 9 to bottom Allow s of Anti Tip overlap Allow 34 overlap block 14 6 opening gt 23 Allow 3 4 min depth overlap 36 Allow FL Floor must counter The support top overlap 100 Ibs height a F 19 to top of floor 24 cabinet min FIGURE 1 _ FIGURES 1 and 2 contain many DrawerMicro Oven measurements for reference when planning the drawer s location E2 FIGURE 2 Check location where the DrawerMicro Oven will be installed for proper electrical supply Your appliance can be built into a cabinet or wall by itself or under a gas or electric wall oven Be sure that the clearance of the floor between the wall oven and the DrawerMicro Oven is a minimum of 2 The microwave interior will easily accommodate a 9 x 13 oblong dish or a bag of microwave popcorn 4 n 21 1 0 12 iii Gp e 15 auto drawer opening 71 Y door thickness
19. o DrawerMicro como un espacio de almacenamiento Esto crea una situaci n potencialmente peligros ESPACIOS LIBRES Y DIMENSIONES e Check that the time of day is in the display If not touch Stop Clear to prevent unintended use e Las dimensiones mostradas en la figura deben ser utilizadas Las dimensiones suministradas proporcionan un espacio libre minimo Ubique el tomacorriente el ctrico en el area cubierta en la esquina superior izquierda del recorte Vea la FIGURA 4 e La superficie de contacto debe ser firme y nivelada Preste mucha atenci n a la superficie o piso en el cual se apoyar el Horno DrawerMicro La superficie o piso de la abertura debe ser construido de madera laminada lo suficientemente resistente para soportar el peso del horno aproximadamente 100 libras MEDIDAS DEL Horno DrawerMicro o k 6 Ubicaci n del tomacorriente Bloque L antivol caduras ma 3 _traslapo Y de Ys 14 e hasta la parte I inferior del bloque Hk antivol Abert Lera esduras undidad Deje un TER 3 min traslapo A TL rfici Altura de une del traslapo soportar mostrador de Ys 100 libras 36 l 19 hasta la superficie del piso Gabinete de 24 min y FIGURA 1 Las FIGURAS 1 y 2 contienen varias medidas de hornos microonda tipo gaveta extra bles para que usted tenga una referencia al planificar la ubicaci n de las
20. uer des blessures s rieuses et pourrait causer des dommages au Four DrawerMicro e N utilisez pas le Four DrawerMicro comme espace de rangement Cela pourrait provoquer des risques de blessure ou de dommages JEUX ET DIMENSIONS e Les dimensions illustr es en FIGURE 1 devraient tre utilis es Les dimensions indiqu es donnent le jeu minimum Situez la prise lectrique dans la zone tram e en haut et a gauche dans le d coup Consultez la FIGURE 4 e Lasurface de contact doit tre solide et plomb Faites tr s attention au sol sur lequel le Four DrawerMicro se posera Le sol devrait tre construit en contreplaqu assez fort pour supporter le poids du four environ 100 livres DIMENSIONS DU Four DrawerMicro Emplacement de prise lectrique Bloc antibasculement it 14 1346 po E Ouverture 4po iusauall de 22 po Pr voir fond du bloc chevau chement de po K Pr voir i antibasculement ouverture ondeur Pe 2 minimum Ere 4 Pr voir ouverture Hauteur de de23 po 4 p de 14 Ac po Plancher doit comptoir 5 A pouvoir de 36 po supporter y 100lbs Pr voir chevauchement 19 po de As po jusqu la surface du sol Placard de 24 po min FIGURE 1 Les FIGURES 1 et 2 contiennent plusieurs dimensions de Four DrawerMicro aux fins de consultation lors de planifier l emplacement du lectrom nager F2 e V rifiez que

Download Pdf Manuals

image

Related Search

Related Contents

Conceptronic C150UAND  Topcom Cordless DECT-phone - Twin Black  BEDIENUNGSANLEITUNG  SUV_Yeti_Amundsen_InfotainmentNavigation  AdtempTM ULTRA 417 Digital Fieberthermometer  Manuel d`utilisation du logiciel Interact  Samsung Lavatrice WF60F4EDW2W User Manual  Dual Electronics Corporation XDVD110BT Car Video System User Manual  