Home

AVERTissEMEnT - Aqua Blue

image

Contents

1. Gap lt lt Figure 2 Carton Contents ITEM DESCRIPTION Power Pack Bracket Pipe Spacer 40 mm 1 in pipe only Screw Set includes wall plugs O Zodiac AquaP ure Ei Series APURE35C Installation and Operation Manual Page 10 Section 3 Installation Instructions WARNING FOR YOUR SAFETY This product must be installed and serviced by a professional pool spa service technician as described on the front cover of this manual The procedures in this manual must be followed exactly Failure to follow warning notices and instructions may result in property damage serious injury or death Improper installation and or operation will void the warranty WARNING EQUIPMENT UNDER PRESSURE Always turn pump off prior to installing or servicing the Zodiac AquaPure Ei Series APURE35C chlorine generating device Your pump filter system is operated under pressure and the pressure must be released before you begin work Please see your pump filter owner s manual for further instructions Disconnect power to the system at the main circuit breaker before performing this procedure to avoid risk of electric shock which can result in property damage severe injury or death 3 2 Installation Requirements WARNING The Zodiac AquaPure Ei Series APURE35C chlorine generating
2. Figure 4 Attaching the Power Pack Page 11 4 Wire the power pack to the LOAD side of the pump or the LOAD side of the pool pump timer relay so that the chlorinator can only come on when the pool pump comes on see Section 3 4 Attach the bonding wire and connect it to a common bonding point see Section 3 5 If available wire the power pack to an AquaLink RS Control System or PDA see Section 3 6 5 Unscrew the locking ring from the cell in order to extract it from the upper clamp see Figure 5 Upper Clamp with Gasket Disassemble Cell Figure 5 6 Press the two 2 push buttons on either side of the upper clamp to separate the upper clamp from the lower clamp see Figure 5 7 Invert the lower clamp and place on the pipe Mark the pipe for drilling the feeder holes see Figure 6 The two holes in the lower clamp serve as a template for the feeder holes Figure 6 Marking Pipe for Drilling Feeder Holes The Goldline brand is property of Hayward Industries Inc and or its subsidiaries or affiliates All other trademarks used herein are the property of their respective owners Zodiac AquaP ure Ei Series APURE35C Installation and Operation Manual 8 Drill the feeder holes using the holesaw provided Ensure holes are clean and smooth see Figure 7 Feeder Holes Figure 7
3. Figure 31 Bouchon d hivernage et outil pour Figure 30 Vue clat e de la cellule anneau de serrage Figure 32 Vue clat e du bloc d alimentation Zodiac AquaPure Ei Series APURE35C Guide d installation et d utilisation NOTES Guide d installation et d utilisation Zodiac AquaPure Ei Series APURE35C NOTES ly Intertek ETL LISTED CONFORMS TO Zodiac Pool Systems Inc UL STD1563 2620 Commerce Way Vista CA 92081 CERTIFIED TO CAN CSA C22 2 NO 218 1 1 800 822 7933 www ZodiacP oolSystems com Zodiac Pool Systems Canada Inc 2115 South Service Road West Unit 3 Oakville Ontario Canada L6L 5W2 1 888 647 4004 www zodiacpoolsystems ca ZODIAC is a registered trademark of Zodiac International S A S U used under license All other trademarks used herein are the property of their respective owners ZODIAC estune marque de commerce d pos e de Zodiac International S A S U utilis e sous licence Toutes les autres marques de commerce mentionn es sont la propri t de leurs propri taires respectifs 2011 Zodiac Pool Systems Inc H0368100 Rev 1112 VA ZODIAC
4. 9 Figure 8 Drilling Feeder Holes Use the pipe spacer as shown if mounting on a 40 mm 1 2 in pipe see Figure 8 Spacer used for 40mm 1 1 2 in pipe only Pipe Spacer NOTE The pipe spacer is required for 40 mm 1 in 10 11 diameter pipe only The spacer is not required on 50 mm 2 in pipe Verify the gasket is attached to the upper clamp The curved side of the gasket must be pointing down so that it will create a seal with the pipe Secure the clamps pipe spacer and gasket around the pipe as shown see Figure 9 making sure the flow arrows on the clamp point in the direction of the water flow see Figure 10 Make sure the two 2 clips on the sides of the clamp are snapped into place Figure 9 Attaching Cell Clamps 12 Insert the o ring into the channel on the clamp and then attach the cell see Figure 10 and 11 a Water Flow Figure 10 Water Flow Arrows The groove must be on the inlet side Figure 11 Cell Attached 13 Position the locking ring in proper alignment making sure the bump aligns with the top thread see Figure 12 Zodiac AquaPure Ei Series APURE35C Installation and Operation Manual Align bump with top thread on the lower clamp Figure 12 Locking Ring Alignment 14 Screw down the locking ring to the threaded clamp using the locking ring tool see Figure 13 NOTE Ensure the l
5. e 4 000 ppm of salt is recommended for optimum water conditions NOTE In cooler water conditions less than 18 C 65 F it may be necessary to add more than 4 500 ppm of salt to keep the Check Salt alarm from appearing on the power pack e Low salt concentration below 3 000 ppm will cause premature cell failure e High salt concentration above 6 000 ppm may cause corrosion damage to pool fixtures Page 22 D ENGLISH Zodiac AquaP ure Ei Series APURE35C Installation and Operation Manual 4 6 4 How to Add Salt to the Pool 1 Turn on pump to circulate pool water 2 IMPORTANT Turn the power pack off by pressing the ON Off button OFF will be displayed on the screen 3 Test the water for salinity level using test strips electronic meter or by your local pool professional 4 Use the Table 1 to determine the amount of salt to add Be conservative when adding salt as it is easier to add more if needed than it is to dilute if there is too much salt 5 Broadcast salt into pool Do not add through skimmer main drain or surge tank Brush the salt around the pool to facilitate dissolving Circulate filter system for 24 hours to ensure even distribution 6 After 24 hours verify correct salt reading by testing the water salinity level using test strips electronic meter or by your local pool professional 7 When the salinity level is correct turn the power pack on Press the OUTPUT button to set t
6. lever rapidement le niveau de chlore Quand la concentration de chlore passe rapidement de 5 15 ppm on dit que l eau de la piscine a t surchlor e chloration choc REMARQUE Lors du d marrage initial de la piscine la surchloration est recommand e en utilisant un traitement choc ou une source recommand e ou homologu e base de dichlorure de sodium d hypochlorite de calcium de chlore liquide ou de trichlorure disponible chez votre fournisseur local d quipement de piscine ATTENTION Ne jamais utiliser d acide sec pour ajuster le pH dans les zones arides des zones g ographiques avec une vaporation excessive et la dilution minimale d eau de piscine l eau douce Une accumulation de sous produits peuvent endommager la cellule lectrolytique e La condition de pH r sultant de l exploitation d un syst me de chloration de l eau sal e est proche de la neutralit Toutefois d autres facteurs causent g n ralement le pH de l eau de la piscine a la hausse Par cons quent le pH dans une piscine chlor e par un syst me d eau sal e ont tendance se stabiliser a environ 7 6 Si le pH de la piscine d passe 7 6 un professionel de piscine peut tester pour voir si d autres facteurs tels que la duret en calcium ou l alcalinit totale sont la cause et ensuite l quilibre en cons quence e Total des solides dissous TDS ajoutant du sel a l eau de piscine l vera le niveau de T
7. eeeeeeesseeeceeeeeeeeeeeeeees 17 Exemple d une installation de A FIVATION assignees danneiedcaatcctenes 18 Nouvelle tuyauterie pour les systemes au sol de la piscine 19 Exemple d une installation alternative 19 Panneau de commande du bloc d alimentation wo eecccseeceseeeeeeseeeeeeees 24 Zodiac AquaP ure Ei Series APURE35C Guide d installation et d utilisation Figure 25 Figure 26 Figure 27 Figure 28 Figure 29 Figure 30 Figure 31 Figure 32 Tableau 1 Tableau 2 D faire l anneau de serrage 27 Enlever la cellule 27 Inverser la cellule 27 Bouchon d hivernisation install 28 Mise au niveau de l anneau de serrage 28 Vue clat e de la cellule eee 33 Bouchon d hivernage et outil pour anneau de serrage 33 Vue clat e du bloc d alimentation 33 Liste de Tableaux Nombre approximatif de kilogrammes livres de sel n cessaires pour obtenir une concentration de 4 000 ppm 4 0 g L 23 Nombre approximatif de kilogrammes livres de stabilisant n cessaire pour obtenir une concentration de 50 ppm 23 Guide d installation et d utilisation Zodiac AquaPure Ei Series APURE35C Section 1 Consignes de s curit importantes LIRE ET SUIVRE TOUTES LES CONSIGNES Le pr sent dispositif ne peut tre utilis que dans des piscine
8. Guide d installation et d utilisation AVERTISSEMENT L utilisation du chlorateur Zodiac AquaPure Ei Series APURE35C sans que l eau circule travers la cellule d lectrolyse pourrait causer une accumulation de gaz inflammables qui pourrait causer un INCENDIE ou une EXPLOSION AVERTISSEMENT e Le bloc d alimentation doit tre install au moins 1 5 m 5 pi au dessus du sol e Le bloc d alimentation doit tre install au moins 3 m 10 pi de la paroi int rieure de votre piscine ou du spa integr AVERTISSEMENT Cet appareil n est pas con u pour tre utilis par des personnes avec des capacit s physiques sensorielles ou mentales r duites ou qui n ont pas assez d exp rience ou de connaissance moins d tre supervis es ou instruites sur l usage de l appareil par la personne responsable de leur s curit AVERTISSEMENT Pour r duire le risque de dommages ne pas enlever la tuyauterie d aspiration de votre spa ou jacuzzi Ne jamais actionner un spa ou jacuzzi si la tuyauterie d aspiration est cass e ou absente Ne jamais remplacer une tuyauterie d aspiration par une qui a une cote inf rieure au valu e inf rieure au taux de d bit sp cifi dans l assemblage de l quipement AVERTISSEMENT VITER LE RISQUE DE NOYADE DES ENFANTS Ne pas laisser personne surtout des jeunes enfants s asseoir mettre le pied s appuyer ou monter sur des appareils faisant partie du syst me op rationnel de la pis
9. Le tartre se forme dans une eau excessivement dure ou dans une eau de piscine qui n est pas bien quilibr e et en tat d entartrage Apr s l installation du chlorateur Zodiac AquaPure Ei Series APURE35C v rifier la cellule chaque mois pour les signes de tartre Si la cellule d lectrolyse a tendance s entartrer il est recommand de l enlever et d en examiner la formation de tartre ou de d bris tous les mois Certains filtres laissent passer des d bris par la cellule qui peuvent se loger entre les plaques de la cellule Une petite formation de tartre est normale Si en regardant travers la cellule vous voyez une formation de tartre excessive entre les plaques ou les d bris nettoyez la cellule comme suit 1 S assurer que l alimentation vers le bloc d alimentation et le syst me de commande a t coup e ou teinte au niveau du disjoncteur Zodiac AquaPure Ei Series APURE35C Guide d installation et d utilisation 2 Avant de retirer la cellule pour le nettoyage fermer toutes les soupapes non n cessaires pour pr venir des pertes d eau 3 Ouvrir le purgeur d air pour lib rer la pression dans le syst me de la piscine 4 Retirer le capuchon de la borne et les fils de la cellule 5 D faire l anneau de serrage S il y a lieu utiliser l outil pour anneau de serrage pr vu voir Figure 25 Outil pour anneau de serrage Figure 2
10. 8 2 Vues clat es semaine 69 Page 40 Figure 1 Figure 2 Figure 3 Figure 4 Figure 5 Figure 6 Figure 7 Figure 8 Figure 9 Figure 10 Figure 11 Figure 12 Figure 13 Figure 14 Figure 15 Figure 16 Figure 17 Figure 18 Figure 19 Figure 20 Figure 21 Figure 22 Figure 23 Figure 24 Liste de Figures Exemple d installation 8 Contenu de l emballage cscs 9 Exigences d installation esce 10 Fixer le bloc d alimentation sese 11 D monter la cellule 11 Marquer les trous dans le tuyau avant le per age issus 12 Percer les trous dans le tuyau as 12 carteur de tuyau sscsccsceesssssesesees 12 Fixer le collier de serrage d la cellule scene 12 Fl ches du d bit d eau asss 12 Cellule fix e 13 Alignement d anneau de blocage 13 Anneau de serrage 13 Blocage du niveau de l anneau de blo cag sis te 13 Connecter les fils de sortie dela celle sci as issue 13 Fixer le capuchon terminal 00 13 Sch ma de c blage 240 V CA O 120 VOA ersen 14 Acc s et c blage la carte de circuit IMPRIM erse i na int 16 C blage du bloc d alimentation au module d alimentation AquaLink RS ou PDA 17 Raccordement de communication entre le bloc d alimentation et le syst me de commande AquaLink RS ou le r seau PDA
11. invers e la cellule continuera a produire du chlore REMARQUE CLEANING nettoyage sera affich sur l cran pendant les cing 5 minutes de la p riode WAIT attente L indicateur de niveau de production ne changera pas durant le nettoyage 5 7 Pile de secours Le bloc d alimentation est quip d une pile rechargeable qui peut fonctionner pendant plus de 500 heures sans tre connect e une source de courant En cas d une panne de courant la pile conservera TOUS les r glages Si la pile perd sa charge le microprocesseur de l appareil conservera les configurations suivantes de fa on permanente e Heures de fonctionnement e Heures de fonctionnement de la cellule e R glage du dispositif de commande Guide d installation et d utilisation Section 6 Instructions d entretien Avant d effectuer l entretien du chlorateur Zodiac AquaPure Ei Series APURE35C veuillez vous assurer d avoir lu et compris la section Instructions importantes de s curit IMPORTANT Toujours tester les niveaux de chlore dans votre piscine avant chaque utilisation 6 1 Entretien quotidien 1 Essai de chlore Servez vous d une trousse d analyse fiable pour v rifier la concentration du chlore dans l eau de la piscine V rifier la date d expiration de la trousse d analyse d eau car les r sultats peuvent tre inexacts s il est utilis apr s la date indiqu e Maintenir un niveau id al en r g
12. it is not necessary to add chlorine stabilizer to the swimming pool water Metals Test It is recommended that the pool water be tested periodically for the presence of metals such as iron and manganese These metals should not be present in the pool water If those metals are present contact your local pool professional DO NOT add pool or spa chemicals directly to the skimmer This may damage the cell Zodiac AquaP ure Ei Series APURE35C Installation and Operation Manual Page 26 6 3 Cleaning the Cell WARNING Disconnect power to the system at the main circuit breaker before performing this procedure to avoid risk of electric shock which can result in property damage severe injury or death WARNING e When cleaning the cell wear protective eyeglasses and gloves e When mixing acid with water ALWAYS ADD ACID TO WATER NEVER ADD WATER TO ACID The power pack has an automatic cell cleaning feature polarity reversing that removes scale deposits from the cell see Section 5 6 Scale will form in excessively hard water or from pool water that is out of balance and in a scaling condition Following the installation of the Zodiac AquaPure Ei Series APURE35C chlorine generating device check the cell once a month for signs of scale If the cell has a tendency to scale it is recommended that every month the cell be removed and inspected for scale formation and or debris Some filters allow debris to pass
13. trop faible Augmentez le taux de production de chlore en appuyant sur le bouton de r glage du taux de production de chlore Voir Section 5 4 Augmentations r centes de la temp rature environnementale sans augmentation de la production de chlore de votre appareil Perte temporaire du chlore du aux lourdes charges organiques pluie feuilles engrais ou grande quantit de nageurs Animaux domestiques utilisant la piscine Augmentez le taux de production de chlore en appuyant sur le bouton de r glage du taux de production de chlore Voir Section 5 4 R gler la production de chlore 100 et faire fonctionner la pompe et la cellule pendant 24 heures Apr s 24 heures rev rifier les niveaux du chlore Si le niveau est toujours trop faible surchlorer avec une autre source Faible niveau de sel inf rieur 3 500 ppm dans l eau de la piscine Utiliser des bandelettes pour tests de salinit un compteur de salinit mati res totales dissoutes ou toute autre m thode s re pour tester la salinit de l eau de piscine Une fois que le taux existant de salinit a t d termin utiliser le tableau 1 la Section 4 7 4 pour d terminer quelle quantit de sel ajouter pour atteindre le niveau d sir Maintenir un niveau de salinit entre 4 000 ppm et 4 500 ppm Niveau lev de nitrate Communiquer avec un professionnel en piscine M taux pr sents dans l eau de la piscine Communiq
14. 13 240 VAC or 120 VAC Wiring Diagram 14 Accessing and Wiring to the Power PCB iison 16 Wiring Power Pack to an AquaLink RS or PDA Power Center 240 VAC and 120 VAC 17 Communication Wiring between Power Pack and AquaLink RS or PDA Power CONGR E E EE E 17 Example of Bypass Installation 18 New Pool Plumbing for In Floor Systems 19 Example of Alternative Installation 19 Control Panel on the Power Pack 24 Undo Locking Ring 26 Remove the Cell ss 26 Invert The Cell 26 Winterizing Cap Installed eee 28 Locking Ring LOVE 28 Cell Exploded View 33 Winterizing Cap and Locking Ring Tool essri 33 Power Pack Exploded View ee 34 Table 1 Table 2 List of Tables Approximate Kilograms Pounds of Salt Needed to Obtain 4 000 ppm 4 0 gpl 23 Approximate Kilograms Pounds of Stabilizer Needed to Obtain Zodiac AquaPure Ei Series APURE35C Installation and Operation Manual Page 5 Section 1 Important Safety Instructions READ AND FOLLOW ALL INSTRUCTIONS This device can only be used in swimming pools and swimming pools with a built in spa It cannot be used in stand alone spas All electrical work must be performed by a licensed electrician and conform to all national provincial and local codes When installing and using this electrical equipment basic safety precautions should always be followed
15. 8 lbs 2 3 kgs 5 1 Ibs 2 9 kgs 6 3 Ibs 3 4 kgs 7 6 Ibs 4 0 kgs 8 9 Ibs 30 0 8 kgs 1 7 Ibs 1 2 kgs 2 5 lbs 1 5 kgs 3 4 Ibs 1 9 kgs 4 2 Ibs 2 3 kgs 5 1 Ibs 2 7 kgs 5 9 Ibs 40 0 4 kgs 0 8 Ibs 0 6 kgs 1 3 Ibs 0 8 kgs 1 7 Ibs 1 0 kgs 2 1 Ibs 1 2 kgs 2 5 Ibs 1 3 kgs 3 0 Ibs NOTE The above chart is for general reference only The recommended stabilizer reading is between 10 50 ppm and will vary dependent on geographic climate Warm sunny climates will require a stabilizer reading at the higher end of the given range Consult your local pool professional for your optimum level Always add stabilizer according to manufacturer s instructions For indoor pools it is not necessary to add chlorine stabilizer to the swimming pool water Zodiac AquaP ure Ei Series APURE35C Installation and Operation Manual Section 5 Operating Instructions WARNING To avoid property damage serious injury or death do not operate the electrolytic cell without water circulation A buildup of flammable gasses which can result in FIRE OR EXPLOSION 5 1 Control Panel Indicates level of chlorine output production Each light represents a 20 increment of output production Check Indicates there salt is not enough level flow through indicator the cell 0000 Output e AQUAPURE i Series Figure 24 Control Panel on the Power Pack 5 2 Turning Power Pack On Off Manually To turn the
16. EXPLOSION Afin de r duire le risque de blessures ne laisser pas d enfants faire fonctionner le pr sent dispositif Un cordon d alimentation endommag doit seulement tre remplac par le fabricant le responsable d entretien ou l lectricien Lors de l installation et de l utilisation de cet quipement lectrique des pr cautions de base doivent toujours tre suivies Avant l installation couper toute alimentation en courant Brancher un circuit qui est prot g par un disjoncteur de fuite la terre GFCI Ne pas installer dans une enceinte ext rieure ou sous les bords d un jacuzzi ou d un spa AVERTISSEMENT L installation doit tre effectu e conform ment au code lectrique canadien CEC ou C22 1 et ou tous les autres codes locaux ou nationaux RISQUE DE CHOC LECTRIQUE D INCENDIE DE BLESSURES OU DE MORT Brancher seulement un circuit qui est prot g par un disjoncteur de fuite la terre GFCI Consulter un lectricien certifi s il y a doute S assurer qu un tel disjoncteur soit fourni par l installateur et test r guli rement Pour tester le disjoncteur de fuite la terre appuyer sur le bouton de test Le disjoncteur de fuite la terre doit couper l alimentation lectrique Appuyer sur le bouton de r initialisation L alimentation lectrique doit tre restaur e Si le disjoncteur de fuite la terre ne fonctionne pas de cette fa on le disjoncteur est d fectueux Si l
17. Pr paration de l eau de la piscine ccssseeeteeseeeeees 55 4 1 D terminer la grandeur de la piscine capacit en litres d eau 55 4 2 D terminer la grandeur de la piscine capacit en gallons d eau 56 4 3 Connaissances de chimie essentielles 56 44 Conditions optimales pour l eau de la piscine 57 4 5 Analyse du chlore sis scc snseseseinsssessnrreus 57 4 6 Sel chlorure de sodium NaCl e eee 57 Section 5 Mode d emploi 60 5 1 Panneau de commande 60 5 2 Allumer et teindre le bloc d alimentation manuellement riasin 60 5 3 Allumer et teindre le bloc d alimentation l aide de la minuterie externe de la pompe 60 5 4 Configuration du niveau de production AU CHIOT E eroen ete 60 5 5 Connexion au syst me de commande AquaLink RS PPDA JR 61 5 6 Inversion de la polarit eessen 61 5 7 Pil de SeCOUrS usines crssnar asernuse 61 Section 6 Instructions d entretien 61 6 1 Entretien quotidien 61 6 2 Entretien mensuel ccesssseseseeeeeeeeeeeeeees 62 6 4 l Hivernisation cc cceeeseseseseeeeeeeeseeeeeeceeeeeeeeess 64 Section 7 D pannage cescceseeeseeeeees 65 Section 8 Pi ces de rechange et vues clat es nn rrrnnnrmrrrssnnns 68 8 1 Liste des pi ces oo eee eeeeeeeeeeeeeeeeeeeeeeeees 68
18. alimentation d AquaLink RS ou PDA 240 V CA 120 V CA Relais la pompe du filtre Aux 3 Relais la pompe filtre la pompe 240 V CA filtre 120 V CA Au bloc d alimentation Vers le panneau 240 V CA L de disjoncteurs Au bloc Vers le panneau d alimentation de disjoncteurs cD 120 V CA Figure 19 Cablage du bloc d alimentation au AquaLink RS ou le bloc d alimentation du PDA 240 V CA et 120 V CA 3 6 3 Tester la connexion Bloc d alimentati a no Une fois que le bloc d alimentation a t connect au syst me de commande d AquaLink RS ou PDA suivre ces tapes pour tester la connexion i Mettre en marche le bloc d alimentation et le syst me de commande d AquaLink RS ou de Barrette rouge PDA 4 bornes 7 2 Attendre environ 20 secondes Si la connexion est tablie avec succ s le symbole F appara t dans le coin sup rieur droit de l affichage du bloc d alimentation REMARQUE Si le bloc d alimentation n est pas connect au dispositif de commande teindre les deux J appareils et r p ter les tapes 1 et 2 Si le bloc eau lectrique d alimentation n est toujours pas connect au dispositif de commande v rifier de nouveau les connexions Voir Section 3 6 2 et la configuration F du dispositif de commande su
19. appareil Veuillez lire toutes les instructions et consignes de s curit dans la section Instructions de s curit importantes Avant d effectuer tout c blage lectrique s assurer de lire et de suivre toutes les consignes de s curit Le c blage doit tre fait uniquement par un technicien qualifi Utiliser seulement des conducteurs de cuivre Con us pour un minimum de 90 C Carte de circuit imprim du bloc d alimentation Transformateur c bl pour 240 V CA ou 120 V CA MINUTERIE DE LA POMPE DE PISCINE PANNEAU DE DISJ ONCTEURS DU CIRCUIT LA CELLULE El 240 V CA ou 120 V CA 50 60 Hz LIGNE 1 3 c bles LIGNE 2 CONNEXION OPTIONNELLE L AQUALINK RS JAUNE OU ADP ER EE C BLE PLAT DE LA CARTE DE CIRCUIT IMPRIME DU PANNEAU DE COMMANDES MISE LATERRE BO TIER CHARGE 1 BLANC NEUTRE O L AU POINT DE MISE NON UTILIS Pompe LATERRE CHARGE 2 NOIR O Ligne 1 ACT AU POINT DE MISE LATERRE La carte de circuit imprim du bloc d alimentation d tecte automatiquement la tension Figure 17 Sch ma de c blage 240 V CA ou 120 V CA Zodiac AquaPure Ei Series APURE35C 1 Connecter le bloc d alimentation la source de courant de la pompe de piscine en utilisant un fil isol de 3 3 mm2 calibre 12 et un conduit Cabler le bloc d alimentation au c t CHARGE d une pompe ou au c t CHARGE du relais de la minuterie de la pompe de la piscin
20. ces t ches couper l alimentation au niveau du panneau principal disjoncteurs pour viter le risque de choc lectrique pouvant entra ner des dommages mat riels des blessures graves ou la mort Avant de commencer l installation veuillez vous assurer que vous avez les bons outils et un emplacement appropri pour l installation du bloc d alimentation et de la cellule Veuillez vous assurer d avoir lu et compris la section d Instructions importantes de s curit 3 1 Mat riaux et outils Mat riaux d installation fournis e carteur de tuyau pour un tuyau de 40 mm 1 po Scie trous Ensemble de vis incluant bouchons pour les murs Manuel d installation et d utilisation Outils n cessaires pour l installation e Perceuse sans fil ou perceuse lectrique e Foret de 6 mm 15 64 po pour marteau perforateur n cessaire seulement pour percer dans des briques ou du b ton Crayon ou marqueur e Tournevis pointe cruciforme ou foret pointe cruciforme Zodiac AquaPure Ei Series APURE35C Guide d installation et d utilisation 3 2 Exigences d installation AVERTISSEMENT Le chlorateur Zodiac AquaPure Ei Series APURE35C doit tre install l horizontale avec la cellule au dessus du tuyau pour viter une accumulation des gaz inflammables qui pourrait provoquer un INCENDIE OU UNE EXPLOSION Les exigences d installation pour le chlorateur Zodiac Aquapure Ei Series AP
21. completely cured before adding salt Do not run the chlorinator at this time Page 21 Manually chlorinate the pool Contact your dealer for recommendations Follow the pool surface manufacturer s guidelines for your particular pool For vinyl and fiberglass pools salt can be added at start up 4 6 2 What Type of Salt to Use e The purer the salt the better the life and performance of the electrolytic cell Use a salt that is at least 99 8 pure NaCl The salt is an evaporated granulated food quality non iodized salt Consult your salt supplier e Avoid using salt with anti caking agents sodium ferrocyanide also known as YPS or yellow prussiate of soda that could cause some discolouration of fittings and surface finishes in pool e Water conditioning salt pellets are compressed forms of evaporated salt and may be used but will take longer to dissolve e Do not use calcium chloride as a source of salt Use sodium chloride only e Do not use rock salt because insoluble impurities mixed with the rock salt can shorten the life of the unit 4 6 3 How Much Salt to Use Use salinity test strips a TDS salinity meter or another reliable method to test the salinity of the pool water Once the existing salinity has been established use Table 1 to determine the amount of salt to add to reach the desired level Be conservative when adding salt as it is easier to add more if needed than it is to dilute if there is too much salt
22. d un spa ne d passant pas les 10 minutes tant donn que les temp ratures de l eau excessives ont un potentiel lev d endommager le foetus pendant les premiers mois de la grossesse les femmes enceintes ou qui pensent l tre doivent limiter la temp rature de l eau du spa 38 C 100 F Avant d entrer dans un spa ou jacuzzi l utilisateur devrait v rifier la temp rature de l eau l aide d un thermom tre pr cis puisque la tol rance des dispositifs de r gulation de temp rature de l eau varie La consommation d alcool de drogues ou de m dicaments avant ou pendant l utilisation d un spa ou jacuzzi peut entra ner la perte de conscience et la possibilit de noyade Les personnes ob ses ou ayant des ant c dents m dicaux de maladie du c ur de diab te de probl mes circulatoires ou de pression sanguine irr guli re devraient consulter leur m decin avant d utiliser un spa Les personnes qui prennent des m dicaments devraient consulter un m decin avant d utiliser un spa ou jacuzzi puisque certains m dicaments peuvent provoquer la somnolence alors que d autres m dicaments peuvent affecter la fr quence cardiaque la tension art rielle et la circulation Guide d installation et d utilisation Zodiac AquaPure Ei Series APURE35C AVERTISSEMENT Pour un nettoyage appropri les spas doivent tre compl tement vidang s p riodiquement Le nombre de jours entre le VIDANGE COMPLET DU SPA est ga
23. d utilisation Bloc d alimentation la source de courant commune La cellule doit tre le cell derni re piece f d quipement du syst me de circulation de l eau de la piscine juste avant la piscine Options d installation du robinet de r glage Installer entre le c t entr e et le Installer du c t entr e c t refoulement de la tuyauterie du contenant de d rivation lt Aspiration de la piscine Aspiration du spa GC gt Retour la piscine Figure 21 Exemple d une installation de d rivation Retour au spa Zodiac AquaPure Ei Series APURE35C 3 8 Consignes relatives la tuyauterie de retour divis e pour les syst mes de nettoyage au sol Si le chlorateur est utilis avec un syst me de nettoyage au sol il doit tre install sur un tuyau sp cialis pour viter d tre endommag REMARQUE Ne pas installer le chlorateur sur les syst mes au sol qui n ont pas de retour sp cialis pour la piscine tel qu il est indiqu la Figure 22 Cellule La cellule doit tre la derni re pi ce d quipement dans la tuyauterie de retour sp cialis e juste avant la ET ql piscine eo S
24. et au couvercle Zodiac AquaPure Ei Series APURE35C Guide d installation et d utilisation Figure 18 Acc s et c blage la carte de circuit communication imprim Enlever le bouchon blanc qui recouvre le trou Voir Figure 18 Passer le fil du dispositif de commande travers le trou Un passe fil peut tre n cessaire selon la largeur de c ble utilis e Fixer le serre c ble au c ble du dispositif de commande tel qu illustr Voir Figure 18 Dans le tableau lectrique de 1 AquaLink RS ou PDA relier le bloc d alimentation directement au COTE CHARGE du relais de la pompe de filtration Voir Figure 19 L AquaLink RS ou PDA et le bloc d alimentation utilisent une connexion a quatre 4 fils pour communiquer et peuvent tre reli s en tant loign s jusqu un maximum de 500 pi de distance Tout c ble quatre conducteurs pr vu pour l utilisation l ext rieur de calibre minimal de 0 33 mm calibre 22 peut tre utilis Rep rer les bornes vis sur la carte de circuit imprim et relier le bloc d alimentation au AquaLink RS ou la barrette bornes rouge 4 broches du PDA voir Figure 20 REMARQUE Les bornes vis de l AquaLink RS ou PDA sont amovibles pour faciliter l installation Guide d installation et d utilisation Zodiac AquaPure Ei Series APURE35C Bloc d
25. including the following WARNING EQUIPMENT UNDER PRESSURE Always turn pump off prior to installing or servicing the power pack or cell Your pump filter system is operated under pressure and the pressure must be released before you begin work Please see your pump filter owner s manual for further instructions WARNING Zodiac AquaPure Ei Series APURE35C chlorine generating devices are designed for domestic residential swimming pool use only Contrary use could affect performance void warranty and may result in property damage serious injury or death Heavy pool or spa usage and higher temperatures may require higher chlorine output to maintain proper free available chlorine bromine residuals Operating a chlorine generator without water flowing through the cell may cause a build up of flammable gases resulting in fire or explosion To reduce the risk of injury do not permit children to operate this device A damaged supply cord should only be replaced by the manufacturer service agent or electrician When installing and using this electrical equipment always follow basic safety precautions Before performing installation disconnect all power Connect to a circuit that is protected by a ground fault circuit interrupter GFCI Do not install within an outer enclosure or beneath the skirt of a hot tub or spa WARNING Installation must be done in accordance with the Canadian Electrical Code CEC or C22 1 an
26. locales Il faut effectuer une liaison lectrique au bloc d alimentation Guide d installation et d utilisation 3 6 Connexion un syst me de commande AquaLink RS ou PDA optionnel L appareil AquaLink RS ou PDA est un dispositif de commande de piscine multifonctionnel qui peut compl tement g rer le fonctionnement du chlorateur AquaPure Ei La cadence de production de chlore du chlorateur peut tre r gl e partir du menu principal de l AquaLink RS ou PDA L AquaLink RS et PDA permet de configurer le pourcentage de production s par ment pour la piscine et le spa Pour plus d information r f rez vous au Manuel d utilisateur d AquaLink RS ou PDA REMARQUE Le chlorateur AquaPure Ei communique avec tous les mod les d AquaLink r v K ou sup rieure 3 6 1 V rifier si le type de r gulateur sur le bloc d alimentation est r gl correctement Avant de c bler a un syst me de commande d AquaLink RS le type de r gulateur doit tre r gl sur JANDY L M pour permettre la communication entre le bloc d alimentation et le syst me de commande AquaLink RS Le bloc d alimentation est configur par d faut sur le type de r gulateur Jandy L M Suivre les instructions ci dessous pour verifier si le type de r gulateur est configur correctement REMARQUE Le type de r gulateur doit tre r gl correctement avant d effectuer le c blage entre le bloc d alimentation et l AquaLink autremen
27. repeat steps 1 and 2 If the power pack still does not connect to the controller re check the wiring connections see Section 3 6 2 and the controller setting on the power pack see Section 3 6 1 Zodiac AquaPure Ei Series APURE35C Installation and Operation Manual Page 17 AquaLink RS or PDA Power Center 240 VAC 120 VAC To Filter Pump 120 VAC To Filter Pump 240 VAC 4 l 2 E v 2 To Power Pack aus To Breaker 240 VAC Panel To Power Pack 120 VAC 3 7 Bypass Plumbing Instructions If Flow Rate Exceeds 348 L min 92 GPM WARNING If flow rate exceeds 348 L min 92 gpm the cell must be plumbed on bypass otherwise it may result in property damage personal injury or death Red 4 Pin Terminal Bar NOTE Pool pumps greater than 2 HP may produce flow rates exceeding 348 L min 92 gpm If you are unsure of the flow rate of your pool pump contact your dealer for assistance The maximum flow rate for the cell is 348 L min 92 gpm If flow rate exceeds 348 L min 92 gpm the cell MUST be plumbed on bypass see Figure 21 A control Power Center valve must be installed to regulate the flow through the cell It can be installed on the inlet side of the cell or between the inlet and discharge side of the bypass piping Figure 20 Communication Wiring between P
28. sulter en des dommages mat riels des blessures graves ou m me la mort L installation ou l utilisation inappropri e annulera la garantie L installation ou l utilisation inappropri e peuvent cr er un danger lectrique ind sirable qui peut provoquer des blessures graves des dommages la propri t ou la mort L utilisation des mod les Zodiac Aquapure Ei Series APURE35C sans que l eau circule travers la cellule lectrolytique pourrait causer une accumulation de gaz inflammables qui pourrait causer un INCENDIE ou une EXPLOSION GARDER HORS DE LA PORT E DES ENFANTS Zodiac AquaPure Ei Series APURE35C Guide d installation et d utilisation AVIS L UTILISATEUR Ce produit antiparasitaire doit tre employ strictement selon le mode d emploi qui figure sur la pr sente tiquette L emploi non conformes a ce mode d emploi constitue une infraction la Loi sur les produits antiparasitaires L utilisateur assume les risques de blessures aux personnes ou de dommages aux biens que l utilisation du produit peut entra ner e Protection maximale de surintensit 15 A e Utiliser les conducteurs de cuivre seulement e D brancher l alimentation lectrique avant d ouvrir le couvercle de service e Pour usage int rieur ou ext rieur e Exigences lectriques 120 240 V CA 50 60 Hz 3 FILS 1 3 A e Production maximale d acide hypochloreux quivalente 420 g de chlore libre disponible par jour e 4000
29. through to the cell which could lodge between the plates in the cell A small amount of scale formation is normal If by looking through the cell it is observed that there is excessive scale formation between the plates or debris is present the cell must be cleaned as follows 1 Ensure that all power to the power pack and the controller is disconnected turned off at the circuit breaker 2 Before removing the cell for cleaning shut off any necessary valves to prevent any water loss 3 Open the air relief valve to release any pressure in the pool system 4 Remove the terminal cap and cell leads 5 Undo the locking ring If required use the locking ring tool provided see Figure 25 Locking Ring Tool Figure 25 Undo Locking Ring 6 Remove the cell see Figure 26 Figure 26 Remove the Cell 7 Refit the cap on the cell and invert see Figure 27 Figure 27 Invert the Cell Zodiac AquaPure Ei Series APURE35C Installation and Operation Manual 8 With protective glasses and gloves on add one 1 part muriatic acid to ten 10 parts water and mix 9 Fill the cell to the top of the electrode plates with the acid solution A foaming action will begin which is caused by scale calcium carbonate being dissolved from the plates If rigorous foaming action does not begin the cell does not need to be cleaned STOP THE CLEANING PROCE
30. vous m langez l acide l eau TOUJOURS AJOUTER L ACIDE L EAU NE JAMAIS AJOUTER L EAU L ACIDE Quelques conseils utiles e Le maintien des niveaux de sel et de chlore brome au dessus des limites recommand es peut contribuer a la corrosion de l quipement de piscine ou de spa e Choisir des plantes qui peuvent r sister aux les claboussures d eau de piscine contenant du chlore ou du sel et d autres produits chimiques de purification e Toutes les pi ces m talliques utilis es l int rieur ou proximit de la piscine doivent tre fabriqu es en acier inoxydable de bonne qualit e Une s lection minutieuse de produits de ma onnerie La porosit et la duret des pierres naturelles varient consid rablement Nous vous recommandons donc de discuter avec l entrepreneur responsable de travaux de ma onnerie pour choisir la meilleure solution en ce qui concerne les pierres utiliser autour de votre piscine ou du spa e Scellement de tous les produits de ma onnerie Les professionnels de l industrie de pierre pr cisent qu il faut sceller m me les pierres naturelles particuli rement si elles sont utilis es l ext rieur pour emp cher le vieillissement les t ches et la d gradation pr matur e Discutez avec les responsables des travaux de ma onnerie et de la construction de la terrasse pour bien s lectionner le scellant pour les produits de ma onnerie qui seront utilis s autour de votre piscine ou du s
31. 0 L 35 000 gal 530 kgs 1 168 Ibs 497 kgs 1 095 lbs 464 kgs 1 022 lbs 431 kgs 949 Ibs 397 kgs 876 Ibs 364 kgs 803 Ibs 331 kgs 730 Ibs 298 kgs 657 Ibs 265 kgs 584 Ibs 232 kgs 511 Ibs 199 kgs 438 Ibs 166 kgs 365 Ibs 132 kgs 292 Ibs 99 kgs 219 Ibs 66 kgs 146 Ibs 33 kgs 73 Ibs Optimal Nombre approximatif de kilogrammes et de livres de stabilisant n cessaire pour obtenir une concentration de 50 ppm Niveau actuel de l acide cyanurique ppm Grandeur de la piscine du spa en litres gallons am ricains 38 000 L 10 000 gal 57 000 L 15 000 gal 76 000 L 20 000 gal 95 000 L 25 000 114 000 L gal 30 000 gal 132 000 L 35 000 gal 0 1 9 kgs 4 2 lbs 2 9 kgs 6 3 Ibs 3 8 kgs 8 4 Ibs 4 8 kgs 10 5 Ibs 5 7 kgs 12 6 Ibs 6 7 kgs 14 8 Ibs 10 1 5 kgs 3 4 Ibs 2 3 kgs 5 1 Ibs 3 1 kgs 6 7 Ibs 3 8 kgs 8 4 Ibs 4 6 kgs 10 1 Ibs 5 4 kgs 11 8 Ibs 20 1 1 kgs 2 5 Ibs 1 7 kgs 3 8 Ibs 2 3 kgs 5 1 lbs 2 9 kgs 6 3 Ibs 3 4 kgs 7 6 Ibs 4 0 kgs 8 9 Ibs 30 0 8 kgs 1 7 lbs 1 2 kgs 2 5 Ibs 1 5 kgs 3 4 Ibs 1 9 kgs 4 2 Ibs 2 3 kgs 5 1 Ibs 2 7 kgs 5 9 lbs 40 0 4 kgs 0 8 Ibs 0 6 kgs 1 3 Ibs 0 8 kgs 1 7 lbs 1 0 kgs 2 1 Ibs 1 2 kgs 2 5 Ibs 1 3 kgs 3 0 Ibs REMARQUE Le tableau suivant est fourni a titre de r f renc
32. 5 D faire l anneau de serrage 6 Retirer la cellule Voir Figure 26 ET LJ Figure 26 Enlever la cellule 7 Remettre le bouchon sur la cellule puis inverser Voir Figure 27 FRAN AIS Figure 27 Inverser la cellule 8 En portant des lunettes de protection et des gants ajouter une 1 partie d acide chlorhydrique dix 10 parties d eau puis m langer 9 Remplir la cellule avec la solution acide jusqu au dessus des plaques lectrodes Une formation de mousse commencera provoqu e par la dissolution du tartre carbonate de calcium sur les plaques Si aucune action mousseuse ne se d clenche la cellule n a pas besoin d tre nettoy e ARR TER LE PROC D DE NETTOYAGE passer l tape 10 Autrement laisser la cellule reposer dans la solution jusqu qu il n y ait plus de mousse environ 5 10 minutes 10 Apr s le nettoyage de la cellule vous pouvez disposer de la solution en la versant dans l eau de la piscine ou en l liminant conform ment la r glementation locale 11 Bien rincer la cellule avec de l eau du robinet et inspecter Si les d p ts sont encore visibles sur la cellule d lectrolyse refaire l tape 9 REMARQUE Un nettoyage excessif l eau acide endommagera la cellule d lectrolyse Ne pas laisser dans l acide pendant plus de 30 minutes 12 Si la cellule est propre remettre la cellul
33. ContentS sssssssastarisaneeenreeannse 9 Section 3 Installation Instructions 10 3 1 Materials and Tools 10 3 2 Installation Requirements 10 3 3 Installing the Power Pack and Cell 11 3 4 Wiring the Power Pack to Power Source 13 3 9 BOMCIAG saie a 15 3 6 Connection to an AquaLink RS Control System or PDA Optional vis saunas 15 3 7 Bypass Plumbing Instructions If Flow Rate Exceeds 348 L min 92 GPM e eeeeeeeeenees 17 3 8 Split Return Plumbing Instructions for Infloor Cleaning Systems 18 3 9 Alternative Installation When Pipe is Obstructed s ssssseesssrrsnsesrrresnns 19 Section 4 Pool Water Preparation 19 4 1 Determining Pool Size Litres of Water in Your Pool 19 4 2 Determining Pool Size Gallons of Water in Your Pool 20 4 3 Chemistry You Need to Know 20 4 4 Optimum Pool Water Conditions seese 21 4 5 Chlorine Testing sistccctiiiecscedisintscecdesieecccdeaeteee 21 4 6 Salt NaCl Sodium Chloride 0 0 0 eee 21 Section 5 Operating Instructions 24 9 1 Control Panel 24 5 2 Turning Power Pack On Off Manually 24 5 3 Turning Power Pack On Off Using the Pump s External Timer 24 5 4 Setting the Chlorine Output Level 24 5 5 Connection to an AquaLink RS PDA Control SYSLSM ss ssh ne 24 5 6 Polarity Reversal ss 24 5 7 Backup Battery sise d ess
34. DS Bien que cela ne nuise pas la chimie de l eau de piscine ou de clart l analyse de l eau piscine professionnelle pour TDS doit tre au courant que du sel a t ajout pour le syst me de d sinfection La personne effectuant le test TDS soustrirera le niveau de salinit pour arriver un niveau correct TDS Zodiac AquaPure Ei Series APURE35C e Peau de piscine remplie r cemment ou nouvellement remis en tat peut contenir des mati res ind sirables qui pourraient interf rer avec la capacit de l lectrolyseur au sel pour d sinfecter correctement Assurez vous que l eau est test e par un professionel de piscine et correctement equilibr avant de d marrer le syst me de chloration Piscines en b ton neuves ont une demande constante d acide pour six 6 mois Testez souvent et maintenir un pH ad quat pour viter l exc s d chelle de la cellule e Des agents s questrants peut tre utilis pour compenser l eau de source qui peut avoir une duret de calcium anormalement lev Duret calcique lev peut contribuer la formation de tartre dans la piscine Les agents sequestrants aidera garder les min raux en solution et sous certaines conditions peut viter l entartrage de se produire Consulter votre professionnel de la piscine sur l utilisation d un agent s questrant 4 4 Conditions optimales pour l eau de la piscine Conform ment aux normes de Association des
35. Figure 22 New Pool Plumbing for In Floor Systems 3 9 Alternative Installation When Pipe is Obstructed If the only suitable length of pipe is obstructed such as on a multiport valve often found on a sand filter it is acceptable to lean the cell over up to a maximum of 45 degrees see Figure 23 Mark the feeder holes in the same angle that the cell will be leaning to ensure that you drill in the right position Page 19 Figure 23 Example of Alternative Installation Section 4 Pool Water Preparation 4 1 Determining Pool Size Litres of Water in Your Pool e Rectangular Pools Average length metres x average width metres x average depth metres x 1000 litres capacity e Circular Pools Diameter metres x diameter metres x average depth metres x 785 litres capacity e Oval Pools Long diameter metres x short diameter metres x average depth metres x 785 litres capacity e Sloping Sides Multiply total litres by 0 85 litres capacity Page 20 ENGLISH Zodiac AquaP ure Ei Series APURE35C Installation and Operation Manual 4 2 4 3 Determining Pool Size Gallons of Water in Your Pool Rectangular Pools Average length feet x average width feet x average depth feet x 7 5 gallon capacity Circular Pools Diameter feet x diameter feet x average depth feet x 5 9 gallon capacity Oval Pools Long diameter feet x short diameter feet x average depth feet x 5 9
36. H0368100 Rev INSTALLATION AND ZODIAC OPERATION MANUAL ENGLISH FRANCAIS AquaP ure i Series APURE35C Swimming Pool Algicide Bactericide Chlorine Generating Device for Residential Pools DOMESTIC REGISTRATION NO 30232 PEST CONTROL PRODUCTS ACT READ THE LABEL AND OPERATION MANUAL BEFORE USING KEEP OUT OF REACH OF CHILDREN BUILDER INSTALLER Please leave this manual with the pool owner POOL OWNER Please save this manual A WARNING FOR YOUR SAFETY This product must be installed and serviced by a contractor who is licensed and qualified in pool equipment by the jurisdiction in which the product will be installed where such provincial or local requirements exists In the event no such provincial or local requirement exists the installer or maintainer must be a professional with sufficient experience in pool equipment installation and maintenance so that all of the instructions in this manual can be followed exactly Before installing this product read and follow all warning notices and instructions that accompany this product Failure to follow warning notices and instructions may result in property damage personal injury or death Improper installation and or operation will void the warranty Improper installation and or operation can create unwanted electrical hazard which can cause serious injury property damage or death Operating Zodiac Aquapure Ei Series APURE35C models without water flow through the cell can ca
37. NSTRUCTIONS Zodiac AquaPure Ei Series APURE35C Installation and Operation Manual Section 2 System Description To common power source Power Pack Heater 4 Q x FN J i Filter EE JU mms J lt C ait D 7 Pool Intake Spa Intake The cell must be installed as the last piece of equipment in the circulation plumbing system just before the pool D gt lt TT D Pool Return Spa Return Figure 1 Example of Installation 2 1 Product Specifications Zodiac AquaPure Ei Series APURE35C Maximum Operating Pressure 50 psi Input Freq 47 63 Hz Minimum Flow Rate 152 L min 40 gpm Output Voltage 25V DC max Output Current 5A DC Required Salt Level 4 000 ppm 4 0 gpl Dimensions Maximum water volume treated Power Pack L x W x H 132 000 L 35 000 gal 25 4 cm x 11 4 cm x 33 cm 10 in x 4 5 in x 13 in Chlorine Output 0 42 kg 0 93 Ibs per day Electrolytic Cell L x W x H 16 5 cm x 14 cm x 30 5 cm 6 5 in x 5 5 in x 12 in Input Voltages 240 V or 120 V the system Weight auto detects voltage Power Pack 3 2 kg 7 Ibs Input Current 240 VAC 1A Electrolytic Cell 0 9 kg 2 Ibs Input Current 120 VAC 1 3A Zodiac AquaPure Ei Series APURE35C Installation and Operation Manual Page 9 2 2 Product Contents
38. NT teindre le bloc d alimentation en appuyant sur le bouton ON OFF OFF sera affich sur l cran 3 Tester la salinit de l eau l aide des bandelettes pour tests de salinit un compteur lectronique ou par votre professionnel de piscines 4 Utiliser le tableau 1 pour d terminer la quantit de sel ajouter Soyez prudent lorsque vous ajoutez du sel parce qu il est plus facile d ajouter plus de sel que de diluer s il y en a trop 5 Diffuser le sel dans la piscine Ne pas ajouter du sel travers l cumoire le drain de fond ou le r servoir de surpression pandre le sel autour de la piscine pour faciliter la dissolution Faire fonctionner le syst me de filtrage pendant 24 heures pour assurer une distribution uniforme Zodiac AquaPure Ei Series APURE35C Guide d installation et d utilisation 6 Apr s 24 heures v rifier la salinit avec les bandelettes pour tests de salinit un compteur lectronique ou par un professionnel de piscines 7 Lorsque le niveau de salinit est correct allumer le bloc d alimentation Appuyer sur le bouton OUTPUT production pour choisir le taux de production d sir REMARQUE Il est recommand d attendre au moins 30 jours avant d ajouter du sel dans une nouvelle piscine en b ton ou dans une piscine dont la surface a t refaite la surface doit durcir compl tement Suivre les instructions du fabricant de surface de votre piscine particuli re En cas des piscine
39. RTISSEMENT Cette pompe peut tre utilis e avec des piscines install es de mani re permanente et des piscines avec spa int gr Il ne peut pas tre utilis dans des spas autonomes Ne pas utiliser avec des piscines remisables Une piscine permanente est construite dans le sol ou au dessus du sol ou dans un b timent de sorte qu elle ne peut pas tre facilement d mont e et rang e Une piscine remisable est construite pour qu elle puisse facilement tre d mont e pour tre rang e puis remont e a son tat initial AVERTISSEMENT Il est important de noter que certains mat riaux utilis s dans les spas et les piscines ou proximit de ceux ci peuvent tre incompatibles avec les produits chimiques utilis s habituellement pour purifier l eau des spas ou des piscines p ex les acides le chlore le sel les stabilisants etc Zodiac Pool Systems Inc ne garantit pas que l eau chlor e produite par le chlorateur Zodiac AquaPure Ei Series APURE35C n endommagera pas ou ne d truira pas certains types des plantes le rev tement ou les dalles de terrasse et tout autre mat riel utilis l int rieur ou proximit du spa ou de la piscine Avant de s lectionner les mat riaux qui seront utilis s l int rieur de votre piscine ou du spa ou proximit de ceux ci veuillez discuter avec votre entrepreneur des options disponibles pour valuer la compatibilit de tels mat riaux avec les produits chimiques Lorsque
40. SS go to step 10 Otherwise allow the cell to remain in the solution until the foaming has stopped approximately 5 10 minutes 10 After the cell has been cleaned dispose of the solution by pouring it into the pool water or dispose of according to local regulations 11 Rinse the cell thoroughly with clean tap water and inspect If deposits are still visible on the electrolytic cell repeat step 9 NOTE Excessive acid washing will damage the electrolytic cell Do not leave in acid for more than 30 minutes 12 Ifthe cell is clean reattach the cell as described in Section 3 3 The life expectancy of the electrolytic cell is 10 000 hours under normal use conditions When replacing the cell use only replacement cells having a label that clearly states that it is a replacement cell for the chlorine generating device Zodiac AquaPure Ei Series APURE35C REGISTRATION NUMBER 30232 PEST CONTROL PRODUCTS ACT 6 4 Winterizing NOTE Do not use Ethylene Glycol anti freeze in the system Very little chlorine is needed in cold water Operating the chlorinator below 11 C 51 F is not recommended Operating the chlorinator in cold water can shorten the life of the cell If preventative measures are not taken freezing water may cause severe damage to the cell Prevent freeze damage to the cell by running pump continuously or winterize pool by draining water from pump filter and Page 27 all intake and return lines Re
41. Set chlorine production to 100 and set the pump and the cell to run for 24 hours After 24 hours recheck chlorine levels If still too low super chlorinate with alternate source Low less than 3 500 ppm salt level in pool water Use salinity test strips a TDS salinity meter or another reliable method to test the salinity of the pool water Once the existing salinity has been established use Table 1 to determine the amount of salt to add to reach the desired level Maintain a salinity level of 4 000 ppm 4 500 ppm High nitrate level Contact a pool professional Metals present in pool water Contact a pool professional New pool water Not shocked properly upon startup Super chlorinate the pool Clogged or dirty cell Remove cell for inspection and clean if necessary see Section 6 3 Problem Possible Cause Corrective Action Chlorine level too high Chlorine output percentage set too high Decrease the chlorine production rate by pressing the Output button see Section 5 4 Power pack and cell turned on too long If chlorine output is set at the lowest setting and it consistently provides excessive chlorine levels decrease operation time as much as necessary Page 30 EC Zodiac AquaP ure Ei Series APURE35C Installation and Operation Manual Problem Possible Cause Corrective Action No display on LCD screen is blank No power to
42. URE Ei R0512400 9 R Kit Output Cable Assy APURE Ei R0512500 10 R Kit Screws PCB Mounting APURE Ei R0512800 11 R Kit Screws Cover Power Supply APURE Ei R0512900 Miscellaneous 12 R Kit Locking Ring Tool R0512600 13 R Kit Winterizing Kit R0512700 Replacement o ring supplied in this kit Screws are supplied in this kit Zodiac AquaPure Ei Series APURE35C Installation and Operation Manual Page 33 8 2 Exploded Views Ae Team 2 itr Figure 30 Cell Exploded View Figure 31 Winterizing Cap and Locking Ring Tool Page 34 EC Zodiac AquaPure Ei Series APURE35C Installation and Operation Manual Figure 32 Power Pack Exploded View Zodiac AquaPure Ei Series APURE35C Installation and Operation Manual Page 35 NOTES Intertek ETL LISTED CONFORMS TO UL STD 1563 CERTIFIED TO CAN CSA C22 2 NO 218 1 Zodiac Pool Systems Inc 2620 Commerce Way Vista CA 92081 1 800 822 7933 www ZodiacP oolSystems com Zodiac Pool Systems Canada Inc 2115 South Service Road West Unit3 Oakville Ontario Canada L6L 5W2 1 888 647 4004 www zodiacpoolsystems ca ZODIAC is a registered trademark of Zodiac International S A S U used under license All other trademarks used herein are the property of their respective owners ZODIAC est une marque de commerce d pos e de Zodiac International S A S U utilis e sous licence Toutes les autres marques
43. URE35C sont les suivantes e Le bloc d alimentation doit tre install au moins 1 5 m 5 pi au dessus du sol e Le bloc d alimentation doit tre install au moins 3 m 10 pi de la paroi int rieure de votre piscine ou du spa integr e La cellule doit tre install e sur un tuyau lt 0 8 m 2 4 pi apr s les r chauffeurs les pompes et les filtres comme la derni re pi ce d quipement du syst me de tuyauterie de circulation juste avant la piscine Voir Figure 3 e La cellule et le capteur ne doivent pas tre install s plus de 4 6 m 15 pi du bloc d alimentation Voir Figure 3 e Le bloc d alimentation doit tre install moins de 1 m 3 pi d une prise de courant e Le capteur doit tre install en amont de la cellule Il est recommand que la cellule et le capteur soient install s 10 po 0 25 m l un de l autre e Tl est recommand que la cellule et le capteur soient install s 10 po 0 25 m de tout raccord de 90 Bloc SS he i Pa pj 29098 7 o Cellule e 15 pi MAX 0 4m 1 1 3 pi MIN Figure 3 Exigences d installation Zodiac AquaPure Ei Series APURE35C 3 3 Installation du bloc d alimentation et de la cellule AVERTISSEMENT Si vous installez le chlorinateur Zodiac AquaPure Ei S rie APURE35C l adapteur Goldline il faudra que le r gulateur Goldline soit d connect
44. Uf ES De la Pompe gt 0 a Retour la lt nm NE Vers le systeme de nettoyage au sol Figure 22 Nouvelle tuyauterie pour les syst mes de nettoyage au sol de la piscine 3 9 Autre installation lorsque le tuyau est bloqu Si la seule longueur de tuyau est obstru e tel qu avec un robinet multivoies qu on retrouve souvent sur un filtre sable il est permis d incliner la cellule un angle maximal de 45 degr s Voir Figure 23 Marquer les trous au m me angle que celui de l inclinaison de la cellule pour s assurer de percer dans la bonne position Guide d installation et d utilisation Ne pas installer plus de 45 degr s Figure 23 Exemple d une installation alternative Section 4 Pr paration de l eau de la piscine 4 1 D terminer la grandeur de la piscine capacit en litres d eau e Piscines rectangulaires Longueur moyenne m tres x largeur moyenne m tres x profondeur moyenne m tres x 1 000 volume en litres e Piscines circulaires Diam tre m tres x diam tre m tres x profondeur moyenne m tres x 785 volume en litres e Piscines ovales Grand diam tre m tres x petit diam tre m tres x profondeur moyenne m tres x 785 volume en litres e Bords en pente Multiplier le nombre total de litres par 0 85 volume en litres Page 56 4 2 D terminer la grandeur de la piscine capacit en gallons d eau Piscines rectangula
45. Zodiac AquaPure Ei Series APURE35C chlorine generating device on or off press the button NOTE Because the power pack is wired to the pump s power source the power pack can only be turned on when the pump is turned on 5 3 Turning Power Pack On Off Using the Pump s External Timer If the power pack is wired to the pump s external timer and the power to the power pack is on the power pack will automatically turn on and off when the pump turns on and off see Section 3 4 When the power pack is wired as such the only setting that must be set manually is the chlorine output level see Section 5 4 5 4 Setting the Chlorine Output Level When setting the chlorine output level you must consider the size of the pool the amount of use the pool will be receiving and how hot the weather is All these factors weigh greatly on the level of output needed To adjust the output level follow these steps 1 Turn the power pack on by pressing the button 2 Press the XY button to reach the desired output level The minimum setting is 20 one amber light The output can be adjusted in increments of 20 up to 100 If the OUTPUT button is pressed beyond 100 the output level setting will drop back to 20 Output Setting Amount of time cell will run 20 one 1 light Cell will run two 2 min every ten 10 min 40 two 2 lights Cell will run four 4 min every ten 10 min 60 three 3 lights Cell will run s
46. a remis 20 R glage de la Dur e de fonctionnement de la production cellule 20 une 1 La cellule fonctionnera pendant deux 2 lumi re min dans chaque dix 10 min 40 deux 2 lumi res 60 trois 3 lumi res 80 quatre 4 lumi res 100 cinq 5 lumi res La cellule fonctionnera pendant quatre 4 min dans chaque dix 10 min La cellule fonctionnera pendant six 6 min dans chaque dix 10 min La cellule fonctionnera pendant huit 8 min dans chaque dix 10 min La cellule fonctionnera sans arr t Zodiac AquaPure Ei Series APURE35C 5 5 Connexion au systeme de commande AquaLink RS PDA Le chlorateur Zodiac AquaPure Ei Series APURE35C peut tre connect un syst me de commande AquaLink RS ou PDA voir Section 3 6 Pour des instructions d taill es sur le syst me de commande d AquaLink RS ou PDA voir les manuels respectifs 5 6 Inversion de la polarit Le chlorateur Zodiac AquaPure Ei Series APURE35C est une cellule a polarit r versible ce qui signifie qu a toutes les cing 5 heures de fonctionnement la cellule inverse la polarit pour aider a viter l accumulation de calcium sur les plaques de la cellule C est ce qu on appelle parfois la fonction d auto nettoyage de la cellule Pendant la p riode de transition lorsque la cellule inverse la polarit il y a un d lai d attente de cing 5 minutes o la cellule ne produit pas du chlore Une fois la polarit
47. ant d entr e 120 V CA 1 3A Zodiac AquaPure Ei Series APURE35C Guide d installation et d utilisation 2 2 Contenu ne 0 Figure 2 Contenu de l emballage Description carteur de tuyau pour tuyau de 40 mm 1 po seulement Ensemble de vis incluant les bouchons pour les murs Page 46 Section 3 Guide d installation AVERTISSEMENT POUR VOTRE S CURIT Ce produit doit tre install et entretenu par un technicien professionnel sp cialis dans l installation et la maintenance des piscines et des spas tel qu il est d crit sur la page couverture du pr sent manuel Les consignes de ce manuel doivent tre suivies scrupuleusement Toute infraction aux consignes de s curit et d emploi pourrait causer des dommages mat riels des blessures graves ou m me la mort L installation ou l utilisation inappropri e annulera la garantie AVERTISSEMENT QUIPEMENT SOUS PRESSION Toujours arr ter la pompe avant d installer ou d effectuer l entretien du chlorateur Zodiac AquaPure Ei Series APURE35C La pompe et le filtre op rent sous pression et la pression doit tre relach e avant de commencer le travail Veuillez consulter le manuel d utilisateur de votre pompe filtre pour plus d instructions Avant d effectuer
48. as de sel base de chlorure de calcium Utiliser du chlorure de sodium uniquement e Ne pas utiliser de sel gemme parce qu il contient des impuret s insolubles qui peuvent raccourcir la dur e de vie de l appareil Page 58 4 6 3 Quelle quantit de sel utiliser Utiliser des bandelettes pour tests de salinit un compteur de salinit mati res totales dissoutes ou toute autre m thode s re pour tester la salinit de l eau de piscine Une fois que le taux existant de salinit a t d termin utiliser le tableau 1 la Section 4 7 4 pour d terminer quelle quantit de sel ajouter pour atteindre le niveau d sir Soyez prudent lorsque vous ajoutez du sel parce qu il est plus facile d ajouter plus de sel que de diluer s il y en a trop e Une concentration de sel de 4 000 ppm est recommand e pour des conditions optimales REMARQUE Dans les conditions que l eau est plus froide moins que 18 C 65 F il peut tre n cessaire d ajouter plus que 4 500 ppm du sel de ne pas laisser apparaitre l alarme check salt sur le bloc d alimentation Des concentrations de sel insuffisantes inf rieures 3 000 ppm raccourciront la dur e de vie de la cellule e Des concentrations de sel lev es sup rieures 6 000 ppm peuvent corroder les quipements m talliques de la piscine 4 6 4 Comment verser le sel dans la piscine 1 Metter la pompe en marche pour faire circuler l eau de la piscine 2 IMPORTA
49. ations de chlore et tacher votre piscine Un professionnel de la piscine pourra faire un essai de d tection des m taux et recommander des m thodes pour les liminer L eau de la piscine ne doit pas contenir de chloramines Lorsque des substances organiques se combinent avec du chlore libre des chloramines se forment Cela emprisonne le chlore libre pr sent dans la piscine et emp che le chlore de d sinfecter l eau Les chloramines rendent aussi l eau trouble et br lent les yeux Faire un traitement choc pour liminer les chloramines avant la mise en service de la piscine Zodiac AquaP ure Ei Series APURE35C Guide d installation et d utilisation e La surchloration br le les substances organiques qui se sont combin es avec le chlore et lib re le chlore pour la d sinfection La surchloration consiste augmenter la concentration de chlore rapidement et substantiellement Pour surchloriner la piscine en utilisant le chlorateur Zodiac AquaPure Ei Series APURE3SC r gler la production de chlore a 100 et faire fonctionner la pompe et la cellule pendant 24 heures e La traitement choc superoxidation est aussi un moyen de br ler les substances organiques qui se sont combin es avec le chlore Cette m thode consiste a ajouter manuellement des produits chimiques utilisation d une source recommand e ou homologu e de dichlorure de sodium d hypochlorite de calcium de chlore liquide ou de trichlorure afin d
50. attery losing its charge the microprocessor in the unit will retain the following settings permanently e Operating hours e Cell hours e Controller setting Section 6 Maintenance Instructions Before servicing the Zodiac AquaPure Ei Series APURE35C chlorine generating device please ensure you have read and understood the Important Safety Instructions section IMPORTANT Always test the chlorine levels of your pool before each use NOTE Daily Chlorine Test Test pool water chlorine level with a reliable test kit Check the expiry date of the test kit as test results may be inaccurate if used after that date Maintain an ideal range by adjusting the chlorine output level on the power pack see Section 5 4 The recommended free chlorine level is 1 3 ppm It is recommended that chlorine test samples be taken from two 2 places one 1 at the pool return line the other well away from the pool return line Compare the two 2 samples A higher level should be found at the pool return line The higher level at the pool return line indicates the system is producing chlorine pH Level Test Test the pH level of your pool with a test kit If necessary adjust to maintain a pH level of 7 4 7 6 see Section 4 3 Installation and Operation Manual Page 25 CAUTION Never use dry acid to adjust pH in arid geographic areas with excessive evaporation and minimal dilution of pool water with fresh water A build
51. au de serrage Figure 13 Anneau de serrage 16 17 J Figure 16 Fixer le capuchon terminal Fixer fermement les fils de sortie de la cellule aux bornes des m mes couleurs Voir Figure 15 Fixer le capuchon terminal Brancher le connecteur du capteur dans le bloc d alimentation Voir Figure 16 Zodiac AquaPure Ei Series APURE35C Guide d installation et d utilisation Page 50 3 4 Cablage du bloc d alimentation la source de courant AVERTISSEMENT Lors de l utilisation de produits lectriques des pr cautions de base doivent toujours tre suivies entre autres e DANGER RISQUE DE CHOC LECTRIQUE POUVANT CAUSER DES BLESSURES GRAVES OU LA MORT Avant de tenter d installer ou d entretenir le mat riel s assurer que l alimentation lectrique alimentant tout appareil a t d branch e ou teinte au niveau du disjoncteur Brancher seulement un circuit prot g par un disjoncteur de fuite la terre La mise la terre est requise L appareil doit tre install par un repr sentant de service qualifi et doit tre cor rectement mis la terre Voir Section 3 5 Liaison lectrique Pour viter des dommages mat riels des blessures graves ou la mort ne jamais utiliser le panneau arri re du chassis du bloc d alimentation pour mettre la terre un autre quipement Lors de l installation laisser un espace d acc s pour l entretien de l
52. ause and then balance accordingly e Total Dissolved Solids TDS Adding salt to pool water will raise the TDS level While this does not adversely affect the pool water chemistry or clarity the pool water professional testing for TDS must be made aware salt has been added for the sanitizing system The individual performing the TDS test will then subtract the salinity level to arrive at the correct TDS level e New pool water in a recently filled or newly refinished pool may contain undesirable matter which could interfere with the salt water chlorinator s ability to sanitize properly Make sure the water is tested by a pool professional and properly balanced before turning on the chlorinator system New plaster pools have a constant acid demand for six 6 months Test often and maintain a proper pH to avoid excess scaling of the cell e Sequestering Agents can be used to compensate for source water which may have unusually high calcium hardness High calcium hardness can contribute to scale formation in the pool Zodiac AquaPure Ei Series APURE35C Installation and Operation Manual Sequestering agents will help keep minerals in solution and under some conditions can prevent scaling from happening Consult your pool professional about the use of a sequestering agent 4 4 Optimum Pool Water Conditions In accordance with Association of Pool and Spa Professionals APSP standards we recommend the following water balanc
53. cateur de d bit est allum la production de chlore est interrompue Les joints statiques de la pompe et de l cumoire sont remplis de d bris qui emp chent la bonne circulation de l eau dans le syst me V rifier et nettoyer les joints statiques de l cumoire Filtre sale Nettoyer le filtre Valves ferm es V rifier et corriger tous les alignements de la valve La pompe ne fournit pas un d bit d eau suffisant V rifier le fonctionnement de la pompe S assurer que la pompe est de la bonne puissance pour le d bit requis Probl me Cause possible Action Corrective La lumi re de sel est allum e et l afficheur indique Check Salt ou Low Temperature v rifier le sel ou temp rature basse REMARQUE La lumi re de sel s allume lorsque le niveau de sel chute en dessous de 3 000 ppm et demeure allum e jusqu ce que le niveau de sel soit au dessus de 4 000 ppm Si un syst me de commande AquaLink RS ou PDA est install lorsque le niveau de sel est bas le RS ou PDA affichera Salt 2900 PPM Check AquaPure Low Salt sel 2 900 ppm v rifier l AquaPure niveau de sel bas Le niveau de sel est inf rieur 3 000 parties par million en fonction de la temp rature d eau Maintenir un niveau de salinit entre 4 000 ppm et 4 500 ppm Voir Section 4 6 ou communiquer avec votre professionnel en piscines Cellule expir e Remplacer la cellu
54. cine Placer les composants de votre syst me op rationnel au moins 3 pieds de la piscine pour que les enfants ne puissent pas utiliser l quipement pour acc der la piscine et se blesser ou se noyer AVERTISSEMENT Les personnes ayant des troubles m dicaux devraient consulter un m decin avant d entrer dans l eau d une piscine ou d un spa L immersion prolong e dans l eau chaude peut provoquer de I hyperthermie L hyperthermie survient lorsque la temp rature interne du corps atteint un niveau sup rieur de plusieurs degr s la temp rature normale du corps de 37 C Les sympt mes d hyperthermie comprennent le vertige l vanouissement la somnolence la l thargie et l augmentation de la temp rature interne du corps Les effets de l hyperthermie comprennent Ignorance du danger imminent Incapacit a sentir la chaleur Incapacit a reconnaitre la n cessit de sortir du spa Incapacit physique a quitter le spa Dommage au foetus chez la femme enceinte Perte de conscience entrainant un risque de noyade AVERTISSEMENT Pour r duire le risque de blessures e l eau du spa ne doit jamais depasser de 40 C 104 F Ne pas exc der 15 minutes de baignade dans l eau d un spa 40 C Les temp ratures de l eau entre 38 C 100 F et 40 C 104 F sont consid r es ad quates pour un adulte en bonne sant Des temp ratures d eau inf rieures sont recommand es pour les enfants et une utilisation
55. cm 18 po sous la surface et bien loin de la conduite de retour de la piscine 4 6 Sel chlorure de sodium NaCl 4 6 1 Quand ajouter du sel Ajouter du sel la piscine si le niveau de sel est trop faible voir Tableau 1 ou si l indicateur de sel est allum Il est recommand d attendre au moins 30 jours avant d ajouter du sel dans une nouvelle piscine en b ton ou dans une piscine dont la surface a t refaite la surface doit durcir compl tement Ne pas faire fonctionner le chlorateur ce moment ci Chlorer la piscine la main Suivre les instructions du fabricant de surface de votre piscine particuli re En cas des piscines en vinyle ou fibre de verre le sel peut tre ajout de la mise en service 4 6 2 Quel type de sel utiliser e Le sel le plus pur possible de pr f rence pour une meilleure performance et une plus longue dur e de vie de la cellule lectrolytique Utiliser un sel qui contient au moins 99 8 de NaCl pur Le meilleur sel est un sel de table raffin granul et non iod Veuillez consulter votre fournisseur de sel e vitez d utiliser du sel contenant des antimottants ferrocyanure de sodium galement appel prussiate jaune de sodium qui pourraient d colorer les raccords et les surfaces finies de la piscine e Les pastilles de sel pour le traitement de l eau sont faites de sel raffin et comprim Elles sont autoris es mais mettent plus de temps se dissoudre e N utiliser p
56. d de 10 50 ppm Suivre les recommandations de votre professionnel en piscine Pour les piscines d int rieur il n est pas n cessaire d ajouter le stabilisateur de chlore l eau de piscine Zodiac AquaPure Ei Series APURE35C Guide d installation et d utilisation 5 Test de m taux Il est recommand de tester p riodiquement la pr sence de m taux comme le fer et la mangan se dans l eau de la piscine Ces m taux ne doivent pas tre pr sents dans l eau de la piscine Si ces m taux sont pr sents dans l eau de votre piscine communiquer avec un professionnel en piscines de votre r gion REMARQUE Ne pas ajouter de produits chimiques pour piscines ou spas directement dans l ecumoir Cela peut endommager la cellule 6 3 Nettoyage de la cellule AVERTISSEMENT Avant d effectuer ces t ches couper l alimentation au niveau du panneau principal disjoncteurs pour viter le risque de choc lectrique pouvant entra ner des dommages mat riels des blessures graves ou la mort AVERTISSEMENT e Lors du nettoyage de la cellule porter des lunettes et des gants de protection e Lorsque vous m langez l acide a l eau TOUJOURS AJOUTER L ACIDE A L EAU NE JAMAIS AJOUTER L EAU L ACIDE Le bloc d alimentation dispose d une fonction de nettoyage automatique de cellule inversion de la polarit qui limine les d p ts de tartre de la cellule d lectrolyse voir Section 5 6
57. d bonded See Section 3 5 Bonding To avoid property damage serious injury or death never use the chassis backplate of the power pack to ground any other equipment Install to permit access for servicing Please read all cautions and safety instructions in the Important Safety Instructions section Before attempting any electrical wiring be sure to read and follow safety instructions Wiring should only be attempted by a qualified professional oo Power PCB Use Copper Conductors Only Rated for 90 C Minimum Factory Wired for POOL 240 VAC or 120 VAC CIRCUIT 240 VAC or 120 VAC 50 60 Hz TO FAN e OPTIONAL CONNECTION TO AQUALINK RS OR PDA TO EARTH BONDING LOAD 2 POINT Pump TO EARTH BONDING POINT The Power PCB auto detects voltage Figure 17 240 VAC or 120 VAC Wiring Diagram Zodiac AquaPure Ei Series APURE35C Installation and Operation Manual 2 Attach the third wire ground from the electrical panel to the ground point inside the power pack Additionally applicable local and or National installation codes may require the equipment to be properly bonded to other pool equipment or to a bonding grid Bonding per Section 3 5 must also be accomplished to ensure personal safety and safety of equipment 3 5 Bonding Canadian Electric Code CEC requires pool equipment to be bonded to each other Check your local codes to determine if other local installation codes are e
58. d or any other local and national installation codes RISK OF ELECTRIC SHOCK FIRE PERSONAL INJURY OR DEATH Connect only to a branch circuit that is protected by a ground fault circuit interrupter GFCI Contact a qualified electrician if you cannot verify that the circuit is protected by a GFCI Make sure such a GFCI should be provided by the installer and should be tested on a routine basis To test the GFCI push the test button The GFCI should interrupt power Push the reset button Power should be restored If the GFCI fails to operate in this manner the GFCI is defective If the GFCI interrupts power to the pump without the test button being pushed a ground current is flowing indicating the possibility of electrical shock Do not use the device Disconnect the device and have the problem corrected by a qualified service representative before using Awire binding screw for grounding labeled is provided inside the power pack To reduce risk of electric shock connect the ground wire to the grounding points in the power pack and of your electric service or supply panel with a conductor equivalent in size to the circuit conductors supplying this equipment The power pack must be interlocked interconnected with the pool pump motor power source to ensure that the chlorinator only operates when the pool pump is operating Page 6 ER Zodiac AquaPure Ei Series APURE35C Installation and Operation Manual WARNING Operating the Zod
59. de commerce mentionn es sont la propri t de leurs propri taires respectifs 2011 Zodiac Pool Systems Inc H0368100 Rev 1112 FAUNE O H0368100 Rev GUIDE D INSTALLATION ZODIAC ET D UTILISATION FRANCAIS AquaPure i Series APURE35C Algicide bactericide pour piscines Chlorateur pour piscines r sidentielles DOMESTIQUE NUM RO D ENREGISTRATION 30232 LOI SUR LES PRODUITS ANTIPARASITAIRES LIRE L TIQUETTE ET LE MODE D EMPLOI AVANT L UTILISATION GARDER HORS DE LA PORT E DES ENFANTS CONSTRUCTEUR INSTALLATEUR Veuillez laisser le pr sent manuel aupr s du propri taire de la piscine PROPRI TAIRE DE LA PISCINE Veuillez conserver le pr sent manuel AVERTISSEMENT POUR VOTRE S CURIT L installation et l entretien de ce produit doivent tre effectu s par un technicien autoris et qualifi pour la r paration des quipements de piscine par la juridiction o le dit produit est install lorsque de telles exigences locales sont dict es Si aucune exigence locale n est disponible l agent d installation ou d entretien doit tre un professionnel avec suffisamment d exp rience dans l installation et la maintenance d quipement de piscine pour appliquer correctement les consignes du pr sent manuel Avant d installer ce produit lisez et respectez toutes les consignes de mise en garde et les instructions incluses avec ce produit Le non respect des avertissements et des instructions pourrait r
60. de l alimentation Zodiac recommande que les proc dures qui requi rent le contact potentiel avec le c blage lectrique sous tension et ou les pi ces autres que les cordons et les fiches qui sont connect es aux prises lectriques soient effectu es par un entrepreneur qui est agr et qualifi en mati re de mat riel de piscine tel qu il est d crit sur la page couverture du pr sent manuel Toute infraction aux consignes de s curit et d emploi pourrait causer des dommages mat riels des blessures graves ou m me la mort AVERTISSEMENT Le Code Canadien de l Electricit CCE exige que l quipement de piscine est li les uns aux autres Assurez vous de v rifier vos codes locaux de d terminer si la CCE et ou d autres codes d installation locaux sont appliqu es par l autorit competente Un fil de cuivre solide de collage 13 3 mm calibre 6 est inclus avec ce produit pour le collage du bloc d alimentation une connexion liaison permanente Reportez vous vos codes localement appliqu e pour le calibre du fil de liaison acceptable Pour viter des dommages mat riels blessures graves ou la mort ne JAMAIS utiliser la plaque arri re du ch ssis du bloc d alimentation la mise la terre de tout autre quipement 1 S assurer que l emplacement de la cellule et le bloc d alimentation vont satisfaire toutes les exigences num r es la Section 3 2 2 Visser le support du bloc d alim
61. device must be installed horizontally with the cell above the pipe to avoid buildup of flammable gases which can result in FIRE OR EXPLOSION The installation requirements for the Zodiac AquaPure Ei Series APURE35C chlorine generating device are as follows e The power pack must be installed at least 1 5 m 5 ft vertically off the ground e The power pack must be installed at least 3 m 10 ft from the inside wall of your swimming pool or built in spa The cell must be installed on a 0 4 m 1 ft horizontal length of pipe after the heaters pumps and filters as the last piece of equipment in the circulation plumbing system just before the pool see Figure 3 The cell must be installed no more than 4 6 m 15 ft from the power pack see Figure 3 e Jtis recommended that the cell be installed 0 25 m Before you begin your installation please check that you have the right tools and a suitable location to install the power pack and cell Please ensure that you have read and understood the Important Safety Instructions section 10 in from any 90 elbow 3 1 Materials and Tools Installation Materials Furnished Pipe Spacer for 40 mm 1 in pipe Hole Saw 4 6m 15ft MAX Screw Set includes wall plugs a i Installation and Operation Manual Cordless Drill or Power Drill 6mm 15 64 in Hammer Drill Bit only necessary if drilling into brick or concrete Pencil or Ma
62. e de mani re ce que le chlorateur ne puisse d marrer que lorsque la pompe de la piscine d marre Voir Figure 17 2 Fixer le troisi me c ble terre du panneau lectrique la borne de mise la terre dans le bloc d alimentation En plus les codes d installation locaux et ou nationaux applicables peuvent exiger que l quipement soit correctement li aux autres quipements de piscine ou une grille de mise la terre Il faut en outre effectuer la liaison lectrique d crite la Section 3 5 pour garantir la s curit des personnes et du mat riel 3 5 Liaison lectrique Le Code lectrique Canadien CECTM exige que tous les quipements de piscine soient li s l un l autre V rifier les codes locaux pour d terminer si les autorit s comp tentes font respecter le CEC et ou les codes d installation locaux Un fil massif en cuivre de 13 3 mm calibre 8 est recommand par le CEC pour la liaison lectrique du bloc d alimentation dans le respect des normes locales R f rez vous aux codes locaux pour conna tre l paisseur acceptable du fil de connexion Relier le point de masse situ sur la partie mf rieure du panneau arri re du ch ssis un point de masse commun Ne pas utiliser le bloc d alimentation comme point de masse commun Chaque appareil de la piscine qui n est pas reli et qui requiert une mise la terre devra tre reli au point de masse commun dans le respect des normes
63. e 25 Section 6 Maintenance Instructions 25 6i DA a 25 6 2 MONNIV sus sors sonner s rmmeressaemerre scans 25 6 3 Cleaning the Cell 26 6 4 Wint riZing ass antenne 27 Section 7 Troubleshooting cccccceeeee 29 Section 8 Replacement Parts and Exploded MWS 32 8 1 Parts LISE siscivssiiineccccavsvencvcnerenensdndsvasaseecdndcanaeenes 32 8 2 Exploded Views 33 Page 4 ENGLISH Zodiac AquaP ure Ei Series APURE35C Installation and Operation Manual Figure 1 Figure 2 Figure 3 Figure 4 Figure 5 Figure 6 Figure 7 Figure 8 Figure 9 Figure 10 Figure 11 Figure 12 Figure 13 Figure 14 Figure 15 Figure 16 Figure 17 Figure 18 Figure 19 Figure 20 Figure 21 Figure 22 Figure 23 Figure 24 Figure 25 Figure 26 Figure 27 Figure 28 Figure 29 Figure 30 Figure 31 Figure 32 List of Figures Example of Installation 8 Carton Contents ss serres 9 Installation Requirements 10 Attaching the Power Pack 11 Disassemble Cell ss 11 Marking Pipe for Drilling Feeder Holes 11 Drilling Feeder Holes 12 Pipe Spaen 12 Attaching Cell Clamps seeren 12 Water Flow Arrows 12 Cell Atta Che issus 12 Locking Ring Alignment 13 LOCKING RING soesoenan 13 Locking Ring Level 13 Connecting Cell Leads 13 Attaching Terminal Cap essees
64. e conditions be maintained on an on going basis to protect the pool finish and the equipment and to ensure the pleasing appearance of the water The Zodiac AquaPure Ei Series APURE35C is warranted to operate properly only if the following conditions are met Free Available Chlorine Total Alkalinity 100 120 ppm Calcium Hardness 200 300 ppm 4 000 4 500 ppm Cyanuric Acid 10 50 ppm for outdoor pools only 4 5 Chlorine Testing If additional chlorine is required due to heavy bather loads use sodium dichlor calcium hypochlorite liquid chlorine or trichlor to maintain an appropriate chlorine bromine residual in the water Use a home test kit or ask your pool professional to test your water Check the expiry date of the test kit as test results may be inaccurate if used after that date It is recommended that chlorine test samples be taken from two 2 places described below Compare the two 2 samples A higher level should be found at the pool return line The higher level at the pool return line indicates the salt water chlorinator system is producing chlorine 1 At the pool return line 2 46cm 18 in below the surface and well away from the pool return line 4 6 Salt NaCl Sodium Chloride 4 6 1 When to Add Salt Add salt to the pool if the salt is too low see Table 1 or if salt indicator light turns on For a new pool or newly resurfaced pool it is recommended to wait at least 30 days surface should be
65. e disjoncteur de fuite la terre coupe l alimentation la pompe sans que le bouton de test soit enfonc il y a alors coulement de courant la terre ce qui indique la possibilit de choc lectrique Ne pas utiliser l appareil D brancher cet appareil et s assurer que le probl me soit r solu par un repr sentant de service qualifi avant de l utiliser Un vis serre fil nomm D est fourni l int rieur du bloc d alimentation pour la mise la terre Pour r duire le risque de choc lectrique brancher le fil de mise la terre aux points de mise la terre du bloc d alimentation de votre service lectrique ou panneau d alimentation avec un conducteur de taille quivalente aux conducteurs de circuit qui alimentent cet quipement Le bloc d alimentation doit tre interconnect la source d alimentation de la pompe de piscine pour garantir que le chlorateur fonctionne uniquement lorsque la pompe est en marche AVERTISSEMENT Pour r duire le risque de choc lectrique d incendie ou d accidents l entretien doit tre fait uniquement par un technicien qualifi sp cialis dans l entretien des piscines AVERTISSEMENT Si un manque d eau est d tect l interrupteur de unit de d bit lectronique est con u pour d sactiver le syst me Interf rer avec le commutateur de d bit lectronique pourrait entra ner des blessures personnelles et ou dommages la cellule Zodiac AquaPure Ei Series APURE35C
66. e g n rale uniquement Le niveau recommand du stabilisateur se situe entre 10 et 50 ppm et variera en fonction du climat g ographique Des climats chauds et ensoleill s n cessitent un niveau de stabilisateur pr s des valeurs sup rieures d une chelle donn e Consulter le professionnel de piscine de votre r gion pour trouver le niveau optimal Ajouter toujours le stabilisateur conform ment aux instructions du fabricant Pour les piscines d int rieur il n est pas n cessaire d ajouter le stabilisateur de chlore l eau de piscine Page 60 Section 5 Mode d emploi AVERTISSEMENT Pour viter des dommages la propri t des blessures graves ou la mort ne pas faire fonctionner la cellule lectrolytique lorsque l eau ne circule pas Une accumulation de gaz inflammables pouvant causer un INCENDIE ou une EXPLOSION 5 1 Panneau de commande Indique le niveau de la production du chlore Chaque lumi re represente une augmentation de 20 de production V rifier l indicateur du 06 000 K de sel On Off Output Indique qu il n y a pas assez d coulement dans la cellule D 4 e AQUAPURE I Series Figure 24 Panneau de commande du bloc d alimentation 5 2 Allumer et teindre le bloc d alimentation manuellement Pour allumer et teindre le chlorateur appuyer sur le bouton REMARQUE Comme le bloc d alimentation est connect la source d alimentation de la po
67. e pool using the Zodiac AquaPure Ei Series APURE35C chlorine generating device set the chlorine production to 100 and then set the pump and the cell to run for 24 hours e Shocking Superoxidation is also a means of burning out the organic material that has combined with chlorine This method involves the manual addition of chemicals use a registered or scheduled source of sodium dichlor calcium hypochlorite liquid chlorine or trichlor to quickly raise the level of chlorine When the chlorine level is quickly raised to 5 15 ppm the pool water is said to have been shocked NOTE On initial startup of a pool it is best to shock using either a shock treatment or a registered or scheduled source of sodium dichlor calcium hypochlorite liquid chlorine or trichlor available at your local pool supplier CAUTION Never use dry acid to adjust pH in arid geographic areas with excessive evaporation and minimal dilution of pool water with fresh water A buildup of by products can damage the electrolytic cell e The pH Condition resulting from the operation of a salt water chlorination system is close to neutral However other factors usually cause the pH of the pool water to rise Therefore the pH in a pool chlorinated by a salt water system tends to stabilize at approximately 7 6 If the pool pH rises above 7 6 have a pool professional test to see if other factors such as high calcium hardness or total alkalinity are the c
68. e tel qu il est indiqu la Section 3 3 La dur e de vie de la cellule lectrolytique est de 10 000 heures dans des conditions d utilisation normales Au moment du remplacement de la cellule utiliser seulement une cellule de remplacement dont l tiquette indique clairement qu il s agit d une cellule de rechange pour dispositif g n rateur de chlore Zodiac AquaPure Ei Series APURE35C NUM RO D ENREGISTREMENT 30232 LOI SUR LES PRODUITS ANTIPARASITAIRES Page 64 6 4 l Hivernisation REMARQUE Ne pas utiliser d thyl ne glycol antigel dans le syst me Une tr s faible quantit de chlore est n cessaire dans l eau froide Le fonctionnement du chlorateur en dessous de 11 C 51 F n est pas recommand Le fonctionnement du chlorateur en eau froide peut diminuer la dur e de vie de la cellule Si des mesures de pr vention ne sont pas prises l eau pr s du point de cong lation peut causer des dommages importants la cellule Pr venir l endommagement de la cellule d au froid en faisant fonctionner la pompe continuellement ou hiverniser la piscine en drainant l eau par la pompe le filtre et toutes les prises et les conduites de retour Retirer la cellule la nettoyer et l entreposer l int rieur Enrouler les fils de sortie de la cellule enrober dans du plastique et coller au bloc d alimentation l aide de ruban adh sif Un bouchon d hivernisation est inclut avec ce produi
69. emperatures have a high potential for causing fetal damage during the early months of pregnancy pregnant or possibly pregnant women should limit spa water temperatures to 38 C 100 F Before entering a spa or hot tub the user should measure the water temperature with an accurate thermometer since the tolerance of water temperature regulating devices varies The use of alcohol drugs or medication before or during spa or hot tub use may lead to unconsciousness with the possibility of drowning Obese persons and persons with a history of heart disease low or high blood pressure circulatory system problems or diabetes should consult a physician before using a spa Persons using medication should consult a physician before using a spa or hot tub since some medication may induce drowsiness while other medication may affect heart rate blood pressure and circulation WARNING It is important to note that certain materials used in and around swimming pools and spas may not be compatible with chemicals commonly used to purify pool and spa water e g acids chlorine salt stabilizers etc Zodiac Pool Systems Inc does not warrant or guarantee that the chlorinated water generated by the Zodiac AquaPure Ei Series APURE35C chlorine generating device will not damage or destroy certain types of plants decking coping and other materials in and around your pool and or spa Before selecting materials to be used in and around your pool and or spa
70. entation un mur o il sera bien fix en s assurant qu il soit plac pas plus de 4 6 m 15 pi de la cellule Voir Figure 4 3 Mettre le bloc d alimentation en place en alignant le support avec les trous correspondants Voir Figure 4 La marque Goldline est la propri t exclusive de Hayward Industries Inc et ou de leurs familles Guide d installation et d utilisation Trous Vis EU Figure 4 Fixer le bloc d alimentation 4 C bler le bloc d alimentation au c t CHARGE de la pompe ou au c t CHARGE du relais de la minuterie de la pompe de la piscine de mani re ce que le chlorateur ne puisse d marrer que lorsque la pompe de la piscine d marre Voir Section 3 4 Fixer le c ble de connexion puis le connecter un point commun Voir Section 3 5 S il y a lieu c bler le bloc d alimentation au syst me de commande RS syst me distance ou au PDA assistant num rique de la piscine AquaLink voir Section 3 6 5 D visser l anneau de serrage de la cellule pour le retirer de la partie sup rieure du collier de serrage Voir Figure 5 Partie sup rieure du collier de serrage avec joint statique Bouton poussoir Partie inferieure du collier de serrage Figure 5 D monter la cellule 6 Appuyer sur les d
71. eux 2 boutons poussoirs situ s sur chaque c t de la partie sup rieure du collier de serrage pour s parer la partie inf rieure de la partie sup rieure Voir Figure 5 Zodiac AquaPure Ei Series APURE35C Guide d installation et d utilisation Page 48 7 Inverser le collier du bas et placer sur le REMARQUE L carteur de tuyau est seulement n cessaire pour l installation avec un tuyau dont le diam tre est de 40 mm 1 po L carteur n est pas obligatoire pour l installation avec un tuyau de 50 mm tuyau Marquer les trous pour percer le tuyau Voir Figure 6 Les deux trous dans la 2 po artie inf rieure du collier yo eo HA en de mod le pour les 10 V rifier si le joint statique est attach la partie trous d alimentation sup rieure du collier de serrage La partie courb e du joint statique doit pointer vers le bas de fa on adh rer au tuyau 11 Fixer les colliers de serrage l carteur de tuyau et le joint statique autour du tuyau tel qu illustr Voir Figure 9 en s assurant que les fl ches de circulation sur le collier pointent dans la direction du d bit d eau Voir Figures 10 et 11 S assurer que les deux 2 attaches sur les c t s du collier de serrage s enclenchent Figure 6 Marquer les trous dans le tuyau avant le per age 8 Percer les trous dans le tuyau l aide de la scie trous fournie S assurer que les trous sont propres et lisse
72. ez de sel dans la piscine Ajouter du sel la piscine jusqu ce que la salinit retourne un niveau de 4 000 ppm 4 500 ppm Voir Section 4 6 3 Une forte pluie a dilu l eau de la piscine Ajouter du sel la piscine jusqu ce que la salinit retourne un niveau de 4 000 ppm 4 500 ppm Voir Section 4 6 3 Fuite dans la piscine R parer la piscine Probl me Cause possible Action Corrective Odeur du chlore Pr sence excessive de Effectuer une chloration choc manuelle chloramine chlore combin Voir Section 4 3 Probl me Cause possible Action Corrective Eau trouble parois de la piscine visqueuse Croissance combin e des algues et des bact ries Brosser les parois affect es et surchlorer la piscine manuellement Voir Section 4 3 Probl me Cause possible Action Corrective Irritation des yeux ou de la peau Mauvais quilibrage d eau Equilibrer l eau aux niveaux recommand s dans la section Section 4 4 Probl me Cause possible Action Corrective Formation de tartre sur l quipement de Ajuster l alcalinit totale entre 100 120 la piscine REMARQUE pour nettoyer les d p ts tartre sur la cellule Voir Section 6 3 pH incorrect qui fait que les min raux sont lib r s de la solution ppm Ensuite r gler le pH un niveau se situant entre 7 4 et 7 6 Voir Section 4 4 F
73. gallon capacity Sloping Sides Multiply total gallons by 0 85 gallon capacity Chemistry You Need to Know Chlorine Stabilizer cyanuric acid is needed to maintain proper levels of chlorine Most non stabilized chlorine is destroyed by the UV radiation from the sun within two 2 hours Chlorine stabilizer should be maintained between 10 50 ppm For indoor pools it is not necessary to add chlorine stabilizer to the swimming pool water Nitrates can cause extremely high chlorine demands and will deplete chlorine from your swimming pool In some cases nitrates may even lower your chlorine levels to zero Your local pool professional can test for nitrates Make sure nitrates are not present in your pool Metals some metals can cause loss of chlorine and stain your pool Have your local pool professional check for metals and recommend methods of removal Chloramines should not be present in pool water When organic materials combine with free chlorine chloramines are formed This ties up the free chlorine in your pool and does not allow the chlorine in your pool to disinfect Chloramines also cloud pool water and burn the eyes Shock to remove chloramines at the initial startup of the pool Super Chlorination burns out the organic material that has combined with chlorine which frees the chlorine for sanitizing Super Chlorination is accomplished by raising the chlorine level quickly and dramatically To super chlorinate th
74. he desired production rate NOTE For anew pool or newly resurfaced pool it is recommended to wait at least 30 days surface should be completely cured before adding salt Follow the pool surface manufacturers guidelines for your particular pool For vinyl and fiberglass pools salt can be added at start up Table 1 Current Salt Level ppm Zodiac AquaPure Ei Series APURE 35C Installation and Operation Manual Page 23 Approximate Kilograms Pounds of Salt Needed to Obtain 4 0 gpl 4 000 ppm Pool Spa Size Litres US Gallons 38 000 L 57 000 L 76 000 L 95 000 L 114 000 L 132 000 L 10 000 gal 15 000 gal 20 000 gal 25 000 gal 30 000 gal 35 000 gal F 0 151 kas Gone 27 kas 601 Tes 209 kas 666 bs 379 xas 035 bs 454 Kos 700 bs si mens Ha kgs 250 bs 57 kg 125 bs 265 kgs 584 Ibs 166 kgs 365 Ibs Table 2 Approximate Kilograms Pounds of Stabilizer Needed to Obtain 50 ppm Current Pool Spa Size Litres US gallons Cyanuric Acid Level ppm 38 000 L 57 000 L 76 000 L 95 000 L 114 000 L 132 000 L 10 000 gal 15 000 gal 20 000 gal 25 000 gal 30 000 gal 35 000 gal 0 1 9 kgs 4 2 Ibs 2 9 kgs 6 3 Ibs 3 8 kgs 8 4 lbs 4 8 kgs 10 5 Ibs 5 7 kgs 12 6 Ibs 6 7 kgs 14 8 lbs 10 1 5 kgs 3 4 Ibs 2 3 kgs 5 1 Ibs 3 1 kgs 6 7 Ibs 3 8 kgs 8 4 lbs 4 6 kgs 10 1 Ibs 5 4 kgs 11 8 Ibs 20 1 1 kgs 2 5 Ibs 1 7 kgs 3
75. iac AquaPure Ei Series APURE35C chlorine generating device without water flow through the electrolytic cell can cause a buildup of flammable gasses which can result in FIRE OR EXPLOSION WARNING The power pack must be installed at least 1 5 m 5 ft vertically off the ground The power pack must be installed at least 3 m 10 ft from the inside wall of your swimming pool or built in spa WARNING This appliance is not intended for use by persons with reduced physical sensory or mental capabilities or lack of experience and knowledge unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety WARNING To reduce the risk of injury do not remove the suction fittings of your spa or hot tub Never operate a spa or hot tub if the suction fittings are broken or missing Never replace a suction fitting with one rated less than the flow rate marked on the equipment assembly WARNING PREVENT CHILD DROWNING Do not let anyone especially small children sit step lean or climb on any equipment installed as part of your pool s operational system Locate the components of your operational system at least 1 m 3 ft from the pool so children cannot use the equipment to access the pool and be injured or drown WARNING People with a medical condition should consult a physician before entering pool or spa water Prolonged immersion in hot water may induce hy
76. ices and instructions may result in property damage serious injury or death Improper installation and or operation will void the warranty When using electrical products basic precautions should always be followed including the following DANGER RISK OF ELECTRIC SHOCK WHICH CAN RESULT IN SERIOUS INJURY OR DEATH Before attempting installation or service ensure that all power to the device is disconnected turned off at the circuit breaker Connect only to a circuit protected by a ground fault circuit interrupter GFCI Grounding is required The unit should be serviced by a qualified service representative and should be properly grounded See Section 3 4 Wiring the Power Pack to Power Source Install to permit access for servicing Please read all cautions and safety instructions in the Important Safety Instructions section Before attempting any electrical wiring be sure to read and follow safety instructions Wiring should only be attempted by a qualified professional 1 Ensure that all power to the power pack and the controller is disconnected turned off at the circuit breaker 2 Remove the screws attaching the cover to the back plate and prop the cover up to expose the terminals see Figure 18 NOTE Be careful not to pull the ribbon cable that is connected to the Power Supply and the Cover 3 Remove the white cap covering the comm hole see Figure 18 4 Thread the controller cable through the ho
77. ires Longueur moyenne pieds x largeur moyenne pieds x profondeur moyenne pieds x 7 5 volume en gallons am ricains Piscines circulaires Diam tre pieds x diam tre pieds x profondeur moyenne pieds x 5 9 volume en gallons am ricains Piscines ovales Grand diam tre pieds x petit diam tre pieds x profondeur moyenne pieds x 5 9 volume en gallons am ricains Bords en pente Multiplier la capacit totale en gallons par 0 85 volume en gallons am ricains 4 3 Connaissances de chimie essentielles Un stabilisateur de chlore acide cyanurique est requis pour maintenir la concentration de chlore des niveaux ad quats Le chlore non stabilis est d truit en grande partie par les rayons ultraviolets du soleil dans les 2 heures Le stabilisateur de chlore doit tre maintenu une concentration de 10 50 ppm Pour les piscines d int rieur il n est pas n cessaire d ajouter le stabilisateur de chlore l eau de piscine Les nitrates peuvent g n rer une consommation de chlore extr mement lev e et faire baisser la concentration de chlore dans votre piscine Dans certains cas les nitrates peuvent m me r duire la concentration de chlore z ro Un professionnel de la piscine de votre r gion peut tester l eau pour d tecter les nitrates Assurez vous qu il n y a pas de nitrates dans l eau de votre piscine Les m taux certains m taux peuvent faire baisser les concentr
78. isplay says Check Salt or Low Temperature Salt light is off A combination of low water temperature 2 18 C 35 65 F and lower salt levels 3 500 4 000 ppm Check salt level in pool water If level is between 4 000 4 500 ppm no action is necessary If salt levels are lower than 4 000 ppm raise the salinity level to 4 000 4 500 ppm see Section 4 6 NOTE Salt levels above 6 000 ppm may cause corrosion damage Zodiac AquaPure Ei Series APURE 35C Installation and Operation Manual Page 31 Problem Possible Cause Corrective Action Output Fault appears on the screen Power supply Turn the power off to the power pack and consult your local pool care professional Problem Possible Cause Corrective Action Salt level too high Too much salt has been added to pool Backwash or partially drain pool and dilute with fresh water until salinity returns to 4 000 ppm 4 500 ppm Problem Possible Cause Corrective Action Salt level too low Not enough salt added to pool Add salt to pool until salinity returns to 4 000 ppm 4 500 ppm see Section 4 6 3 Heavy rainfall diluted the pool water Add salt to pool until salinity returns to 4 000 ppm 4 500 ppm see Section 4 6 3 Leak in pool Repair pool Problem Possible Cause Corrective Action Chlorine odor Presence of excess chloramines c
79. ix 6 min every ten 10 min 80 four 4 lights Cell will run eight 8 min every ten 10 min 100 five 5 lights Cell will run non stop 5 5 Connection to an AquaLink RS PDA Control System The Zodiac AquaPure Ei Series APURE35C chlorine generating device can be connected to an AquaLink RS or PDA Control System see Section 3 6 For detailed instructions for the AquaLink RS or PDA Control System see the respective manuals 5 6 Polarity Reversal The Zodiac AquaPure Ei Series APURE35C chlorine generating device is a reversable polarity cell which means that for every five 5 hours of operation the cell will switch its polarity to help prevent any build up of calcium on the cell plates This is sometimes referred to as the automated cell cleaning feature During the transition between changing its polarity there is a five 5 minute wait time when the cell will not produce any chlorine Once it has changed polarity it will continue to make chlorine NOTE 5 7 Zodiac AquaPure Ei Series APURE 35C CLEANING will be displayed on the screen during the five 5 minute WAIT period The output level indicator will remain as set during the cleaning period Backup Battery The power pack is fitted with a rechargeable battery which can last in excess of 500 hours without the power being connected In the event of a power failure the battery will retain ALL settings In the event of the b
80. l au volume d eau en litres dans le spa divis par 10 fois le nombre maximal d utilisateurs quotidiens du spa Remplir le spa avec de l eau puis r p ter de nouveau les MODE D EMPLOI du dispositif Les personnes avec des maladies infectieuses ne devraient pas utiliser un spa ou jacuzzi Pour viter des blessures faire bien attention en entrant ou en sortant du spa ou jacuzzi Ne pas consommer de drogues ou d alcool avant ou pendant l utilisation d un spa ou jacuzzi afin d viter la perte de conscience ou une possible noyade Les femmes enceintes ou qui pensent l tre devraient consulter un m decin avant d utiliser un spa ou un jacuzzi La temp rature de l eau au dessus de 38 C 100 F peut tre nuisible votre sant Avant d entrer dans un spa ou jacuzzi v rifier la temp rature de l eau l aide d un thermom tre pr cis Ne pas utiliser un spa ou un jacuzzi imm diatement apr s avoir pratiqu une activit physique intense L immersion prolong e dans un spa ou jacuzzi peut tre nuisible votre sant Ne pas placer d appareil lectrique tel qu une lumi re un t l phone une radio ou une t l vision moins de 1 5 m 5 pieds d un spa ou jacuzzi L utilisation de l alcool des drogues ou des m dicaments peut augmenter consid rablement le risque d hyperthermie mortelle dans les spas ou les jacuzzis Une temp rature de l eau sup rieure 38 C 100 F peut tre dangereuse votre sant AVE
81. lant le taux de production du chlore dans le bloc d alimentation Voir Section 5 4 Le niveau de chlore libre recommand se situe entre 1 et 3 ppm REMARQUE Il est recommand de pr lever les chantillons deux 2 endroits diff rents l un la conduite de retour de la piscine et l autre tr s loin de la conduite de retour de la piscine Comparer les deux 2 chantillons La teneur en chlore doit tre plus lev e dans la conduite de retour de la piscine Une teneur plus lev e dans la conduite de retour indique que le syst me produit du chlore 2 Analyse du niveau de pH Analyser le niveau de pH de l eau de votre piscine avec une trousse d analyse du pH Si n cessaire faire des ajustements pour maintenir un pH entre 7 4 et 7 6 Voir Section 4 3 ATTENTION N utiliser jamais un acide sec pour calibrer le pH dans les r gions g ographiques arides ou l vaporation est excessive et la dilution de l eau de la piscine avec de l eau fra che est minimale Une accumulation de produits inutiles peut endommager la cellule lectrolytique Page 62 Analyse de l alcalinit totale Analyser l alcalinit totale de l eau de votre piscine avec une trousse d analyse Prendre les mesures n cessaires pour maintenir une alcalinit entre 100 et 120 PPM voir Section 4 3 Duret calcique Analyser le niveau de duret calcique de l eau de votre piscine avec une trousse d analyse ou fai
82. le Probl me Cause possible Action Corrective L afficheur indique Check Salt or Low Temperature v rifier le sel ou temp rature basse La DEL de sel est teinte La combinaison d une temp rature basse de l eau 2 18 C 35 65 F et de niveaux de sel plus bas 3 500 4 000 ppm V rifier le niveau de sel dans l eau de la piscine Si le niveau se situe entre 4 000 et 4 500 ppm aucune mesure n est n cessaire Si les niveaux de sel sont inf rieurs 4 000 ppm augmenter la salinit 4 000 4 500 ppm Voir Section 4 6 REMARQUE Les niveaux de sel sup rieurs 6 000 ppm pourraient causer la corrosion Zodiac AquaPure Ei Series APURE35C Guide d installation et d utilisation Probl me Cause possible Action Corrective Un bloc d alimentation Output Fault erreur de production appara t sur l cran Couper l alimentation au bloc d alimentation et consulter votre professionnel en piscines Probl me Cause possible Action Corrective Niveau de sel trop lev Trop de sel a t ajout la piscine Faire un lavage contre courant ou drainer partiellement l eau de la piscine et diluer avec de l eau froide jusqu ce que le niveau de salinit se retrouve de nouveau entre 4 000 ppm et 4 500 ppm Probl me Cause possible Action Corrective Niveau de sel trop bas Pas ass
83. le A grommet may be necessary depending on the size of the cable being used 5 Attach a cable tie to the controller cable as shown see Figure 18 Prop the cover onthe two posts located on the back plate gomm Hole Cable Tie Figure 18 Accessing and Wiring to the Power PCB 6 NOTE 3 6 3 In the AquaLink RS or PDA power center wire the power pack directly to the LOAD SIDE of the filter pump relay see Figure 19 The AquaLink RS or PDA and power pack use a four 4 wire connection to communicate and can be wired up to 152 4 m 500 ft apart Any outdoor rated four conductor cable minimum 0 33 mm 22 AWG can be used Locate the appropriate screw terminals on the circuit board and wire the power pack to the AquaLink RS or PDA red 4 pin terminal bar see Figure 20 The screw terminals on the AquaLink RS or PDA are removable to aid in installation Testing the Connection Once the power pack has been wired to the AquaLink RS Control System or PDA follow these steps to test the connection 1 NOTE Apply power to the power pack and the AquaLink RS Control System or PDA Wait about 20 seconds If the connection was successful a F symbol will appear in the top right corner of the power pack display If the power pack does not connect to the controller turn the power off to both devices and
84. move the cell clean and store it indoors Coil the cell leads wrap in plastic and tape to the power pack A winterizing cap is included with this product to replace the cell during winterizing or cell maintenance This will enable pool pump to circulate water with the cell out the of line During the cold season if you are using a FREEZE CONTROLLER on pump equipment and you choose to keep the chlorinator installed turn the CHLORINE PRODUCTION down to 20 otherwise chlorine production will exceed the recommended level of 1 3 6 4 1 Winterizing Procedure WARNING Disconnect power to the system at the main circuit breaker before performing this procedure to avoid risk of electric shock which can result in property damage severe injury or death 1 Ensure that all power to the power pack and the controller is disconnected turned off at the circuit breaker 2 Shut off any necessary valves to prevent any water loss 3 Open the air relief valve to relieve any pressure in the pool system 4 Remove the terminal cap and cell leads 5 Undo the locking ring If required use the locking ring tool provided see Figure 25 6 Remove the cell see Figure 26 7 Attach the winterizing cap see Figure 27 Page 28 EC Zodiac AquaP ure Ei Series APURE35C Installation and Operation Manual Figure 28 Winterizing Cap Installed 8 Position the locking ring in proper alignment making sure the bump aligns with
85. mpe le bloc d alimentation peut tre allum seulement lorsque la pompe est allum e Zodiac AquaP ure Ei Series APURE35C Guide d installation et d utilisation 5 3 Allumer et teindre le bloc d alimentation l aide de la minuterie externe de la pompe Si le bloc d alimentation est connect la minuterie ext rieure de la pompe et que le bloc d alimentation est sous tension le bloc d alimentation s allumera et s teindra automatiquement lorsque la pompe est allum e ou teinte Voir Section 3 4 Lorsque le bloc d alimentation est connect en tant que tel le seul r glage qui doit tre effectu manuellement est le niveau de la production du chlore Voir Section 5 4 5 4 Configuration du niveau de production du chlore Pour configurer le niveau de production du chlore vous devez prendre en consid ration la grandeur de la piscine l usage et la temp rature de l eau Tous ces facteurs influencent gran dement le niveau de production n cessaire Pour ajuster le niveau de la production suivre ces tapes le teindre le bloc d alimentation en appuyant sur le bouton uni 2 Appuyer sur le bouton Er pour atteindre le niveau de production d sir Le niveau de production minimum est de 20 une lumi re ambr e La production peut tre r gl e en paliers de 20 jusqu 100 Si le bouton OUTPUT production est appuy apr s que 100 soit atteint le r glage de niveau de production ser
86. nforced by the Authority Having Jurisdiction AHJ A solid copper 13 3 mm 6 AWG wire is recommended per the CEC for bonding the power pack to a permanent bonding connection that is acceptable to the local AHJ Refer to your locally enforced codes for the acceptable bonding wire gauge Attach the bonding point located on the bottom of the chassis backplate to a common bonding point Do not use the power pack as the common bonding point Each piece of non related pool equipment requiring a ground should also be bonded to the common approved bonding point There should be one bonding connection to the power pack CEC dictates that the bonding conductor be minimum 13 3 mm 6 AWG 3 6 Connection to an AquaLink RS Control System or PDA Optional The AquaLink RS or PDA is a multi function pool controller which can fully control the function of the Zodiac AquaPure Ei Series APURE35C chlorine generating device Adjustment of the chlorine production rate can be controlled from the main menu of the AquaLink RS or PDA The AquaLink RS or PDA offers individual pool and spa settings for output percentage Refer to the AquaLink RS or PDA Owner s Manual for more information NOTE The Zodiac AquaPure Ei Series APURE35C chlorine generating device will communicate with all AquaLink models Rev K or later Page 15 3 6 1 Verify the Controller Type on the Power Pack is Set Correctly Before wiring to an AquaLink RS Control System
87. ocking ring is level when engaging the threading clamp see Figure 14 Locking Ring Figure 14 Locking Ring Level Page 13 15 Securely connect the cell leads to the like colored terminals see Figure 15 16 Attach the terminal cap see Figure 16 Figure 16 Attaching Terminal Cap 3 4 Wiring the Power Pack to Power Source 1 Wire power pack to pool pump power source using 3 3 mm 12 AWG insulated wire and conduit Wire the power pack to the LOAD side of a pump or the LOAD side of the pool pump timer relay so that the chlorinator can only come on when the pool pump comes on see Figure 17 Page 14 ER Zodiac AquaPure Ei Series APURE35C Installation and Operation Manual WARNING When using electrical products basic precautions should always be followed including the following e DANGER RISK OF ELECTRIC SHOCK WHICH CAN RESULT IN SERIOUS INJURY OR DEATH Before attempting installation or service ensure that all power to the device is disconnected turned off at the circuit breaker Connect only to a circuit protected by a ground fault circuit interrupter GFCI Grounding is required The unit should be installed by a qualified service representative and should be properly grounded an
88. ombined chlorine Manually shock the pool see Section 4 3 Problem Possible Cause Corrective Action Cloudy water slimy walls of pool Combined algae and bacteria growth Brush down the affected walls and then manually shock the pool see Section 4 3 Problem Possible Cause Corrective Action Eye and or skin irritation Improper water balance Balance the water to recommended levels in Section 4 4 Problem Possible Cause Corrective Action Scale formation on pool equipment NOTE To clean the deposit scale on the cell see Section 6 3 Incorrect pH causing minerals to come out of solution Adjust total alkalinity to 100 120 ppm Then adjust pH to within the range 7 4 7 6 see Section 4 4 High calcium hardness Dilute pool with fresh water Consult your pool professional regarding use of a sequestering agent Page 32 EC Zodiac AquaPure Ei Series APURE35C Installation and Operation Manual Section 8 Replacement Parts and Exploded Views 8 1 Parts List Key No Description Order Part No Cell 1 R Kit Terminal Cap APURE Ei R0511200 2 R Kit Locking Ring R0511300 3 R Kit Electrode APURE Ei 35 R0511400 4 R Kit O Ring Electrode Housing R0511600 g R Kit Saddle Clamp Assy APURE Ei R0511700 Power Pack 6 R Kit Power PCB Assy APURE 35 R0512100 7 R Kit Control PCB Assy APURE Ei R0512300 or R Kit Cover Assy Controller AP
89. orte duret calcique Diluer l eau de piscine avec de l eau froide Discuter avec votre professionnel en piscines de l utilisation d un s questrant Page 68 Zodiac AquaPure Ei Series APURE35C Guide d installation et d utilisation Section 8 Pi ces de rechange et vues clat es 8 1 Liste des pi ces Num ro de R ference 2 3 4 5 g Orr 10 11 12 13 Description Cellule R Kit Capuchon terminal APURE Ei R Kit anneau de blocage R Kit Electrode APURE Ei 35 R Kit Joint torique chassis d lectrode R Kit Collier de serrage APURE Ei Bloc d alimentation R Kit Carte de circuit imprim pour bloc d alimentation APURE 35 R Kit Carte de circuit imprim pour panneau de commande APURE Ei R Kit Couvercle dispositif de commande APURE Ei R Kit Cable de sortie APURE Ei R Kit Vis Support de carte de circuit imprim APURE Ei R Kit Vis Couvercle Bloc d alimentation APURE Ei Divers R Kit outil pour anneau de serrage R Kit trousse d hivernage Joint torique de rechange fourni dans cette trousse Les vis sont fournies dans cette trousse Num ro de pi ce R0511200 R0511300 R0511400 R0511600 R0511700 R0512200 R0512300 R0512400 R0512500 R0512800 R0512900 R0512600 R0512700 Zodiac AquaPure Ei Series APURE35C Guide d installation et d utilisation 8 2 Vues clat es A lt
90. ower The proper flow will be achieved by adjusting the handle Pack and AquaLink RS or PDA Power of the valve until the red No Flow light has turned off Centre and all large air bubbles are cleared from the cell Page 18 EC Zodiac AquaP ure Ei Series APURE35C Installation and Operation Manual 3 8 Split Return Plumbing Instructions For Infloor Cleaning Systems If the chlorinator is used with an in floor cleaning system it must be installed in a separate dedicated return line or damage to the chlorinator will occur NOTE Do not install the chlorinator on in floor systems that do not have a dedicated pool return as shown in Figure 22 To common power source Power Pack The cell must be installed as the last piece of equipment in the circulation plumbing system just before the pool Control Valve Installation Options Install between the inlet and discharge side of bypass plumbing Install on the inlet side of the vessel Figure 21 Example of Bypass Installation Q Q Pool Intake Spa Intake ITO Pool Return Spa Return Zodiac AquaPure Ei Series APURE35C Installation and Operation Manual The cell must be Cell installed as the last piece of equipment z in the dedicated return plumbing just before the pool From Pump Pool Return To In Floor Cleaning System
91. pa e Pour de meilleurs r sultats les scellants doivent tre appliqu s r guli rement Appliquer le scellant protecteur r guli rement conform ment aux instructions du fabricant e L utilisation de produits chimiques autres que ceux recommand s peut tre dangereuse Suivre les directives des fabricants de produits chimiques CONSERVER CES DIRECTIVES Zodiac AquaP ure Ei Series APURE35C Guide d installation et d utilisation Page 44 Section 2 Description du systeme Vers la source de courant Bloc d alimentation commune Rechauffeur Filtre Aspiration de la piscine Aspiration du spa La cellule doit tre la derni re pi ce d quipement du syst me de circulation de l eau de la piscine juste avant la piscine Retour la piscine Retour au spa Figure 1 Exemple d installation 2 1 Specifications du produit Zodiac AquaPure Ei Series APURE35C Debit minimal 182 Lmin 40 gpm Volume maximal de l eau trait e Bloc d alimentation L x P x H 132 000 L 35 000 gal 25 4 cm 10 po x 11 4 cm 4 5 po x 33 cm 13 po P 7 Cellule d lectrolyse L x P x H Production de chlore 0 42 kg 0 93 Ibs par jour 16 5 cm 6 5 po x 13 97 cm 5 5 po x 30 5 cm 12 po Tensions d entr e 240 V ou 120 V le syst me Poids auto d tecte la tension Bloc d alimentation 3 2 kg 7 Ibs Courant d entr e 240 V CA 1 A Cellule lectrolytique 0 9 kg 2 lbs Cour
92. parties par million de sel e Le volume d eau maximal qui peut tre trait par un appareil APURE35C est de 132 000 litres 35 000 gallons 132 m e Pour les piscines un niveau de 1 3 ppm de chlore libre doit tre maintenu e Contr le les bact ries et les algues dans l eau de la piscine Zodiac AquaPure Ei Series APURE35C Guide d installation et d utilisation Table des mati res Section 1 Consignes de s curit importantes nn ssscrssemeseeanssses 41 Section 2 Description du syst me 44 2 1 Specifications du produit Zodiac AquaPure Ei Series APURE35C irruerunt 44 22 COMENT aa serions 45 Section 3 Guide d installation assssaess 46 3 1 Mat riaux et outils iosian aisin 46 3 2 Exigences d installation 46 3 3 Installation du bloc d alimentation et de la cellule sioguna 47 34 C blage du bloc d alimentation la source de COUFANT 555 5er saresssteaa esse S 50 3 5 Liaison lectrique sieis 51 3 6 Connexion un syst me de commande AquaLink RS ou PDA optionnel 51 3 7 Instructions de tuyauterie de d rivation si le d bit exc de 348 L min 92 GPM ee 53 3 8 Consignes relatives la tuyauterie de retour divis e pour les syst mes de nettoyage AU SOL 22 sc rmatuia saveauarticavemadasandusacntedadesuasiunewceianeas 55 3 9 Autre installation lorsque le tuyau est bloqu eeeeeeeeeeees 55 Section 4
93. perthermia Hyperthermia occurs when the internal temperature of the body reaches a level several degrees above the normal body temperature of 37 C 98 6 F The symptoms of hyperthermia include dizziness fainting drowsiness lethargy and an increase in the internal temperature of the body The effects of hyperthermia include Unawareness of impending danger Failure to perceive heat Failure to recognize the need to exit spa Physical inability to exit spa Fetal damage in pregnant women Unconsciousness resulting in a danger of drowning WARNING This device is intended for use with permanent swimming pools and swimming pools with a built in spa It cannot be used in stand alone spas Do not use with storable pools A permanently installed pool is constructed in or on the ground or in a building such that it cannot be readily disassembled for storage A storable pool is constructed so that it is capable of being readily disassembled for storage and reassembled to its original integrity Zodiac AquaPure Ei Series APURE35C Installation and Operation Manual Page 7 WARNING To Reduce the Risk of Injury e Maximum spa water usage temperature is 40 C Bathing in spa water at 40 C should not exceed 15 minutes Water temperatures between 38 C 100 F and 40 C 104 F are considered safe for a healthy adult Lower water temperatures are recommended for young children and when spa use exceeds 10 minutes Since excessive water t
94. please discuss all options with your contractor to assess the compatibility of such materials and chemicals When mixing acid with water ALWAYS ADD ACID TO WATER NEVER ADD WATER TO ACID Some helpful considerations may include e Maintaining high salt and chlorine bromine levels above recommended range can contribute to corrosion of pool or spa equipment e Choosing plants that can withstand splash out of pool water containing chlorine and or salt and other water purification chemicals All metal components used in and around a pool should be of a high grade quality stainless steel e Careful selection of masonry products The porosity and hardness of natural stones varies greatly Therefore we recommend you consult with your builder or stone contractor on the best choice for stone materials around your pool or spa e Sealing all masonry products Professionals in the stone industry specify that even natural stone especially when used outdoors be sealed to prevent weathering staining and premature degradation Consult with your stone or deck contractor for the proper sealer for the masonry products you have selected to use around your pool or spa e For the optimal results sealers should be reapplied on a regular basis Reapply the protective sealer on a schedule per the manufacturer s instructions e Use of chemicals other than those recommended may be hazardous Follow the chemical manufacturers instructions SAVE THESE I
95. professionnels de piscine et de spa Association of Pool and Spa Professionals APSP nous recommandons de toujours maintenir la composition optimale de l eau afin de prot ger le fini et l quipement de piscine et d assurer la limpidit de l eau Le fonctionnement de Zodiac AquaPure Ei Series APURE35SC est garanti uniquement si ces conditions sont remplies 4000 4500 ppm 10 50 ppm piscine exterieur seulement Acide Cyanurique 4 5 Analyse du chlore Si du chlore supplementaire s av re n cessaire en raison du nombre de baigneurs utiliser du dichlorure de sodium de l hypochlorite de calcium de chlore liquide ou de trichlorure afin de maintenir un niveau de r sidus appropri de chlore brome dans l eau Utiliser une trousse de test maison pour tester l eau ou faire appel un professionnel en piscines V rifier la date d expiration de la trousse d analyse d eau car les r sultats peuvent tre inexacts s il est utilis apr s la date indiqu e Il est recommand de pr lever des Guide d installation et d utilisation chantillons de chlore deux 2 endroits diff rents d crits ci dessous Comparer les deux 2 chantillons La teneur en chlore doit tre plus lev e dans la conduite de retour de la piscine Une teneur plus lev e dans la conduite de retour indique que le chlorateur d eau sal e produit du chlore 1 Dans la conduite de retour de la piscine 2 46
96. r le bloc d alimentation Figure 20 Raccordement de communication entre Voir ee 3 6 1 le bloc d alimentation et le syst me de commande AquaLink RS ou le r seau PDA 3 7 Instructions de tuyauterie de d rivation si le d bit exc de 348 L min 92 GPM AVERTISSEMENT Si le d bit d passe 348 L min 92 gpm la cellule doit tre raccord e sur la d rivation autrement elle pourrait provoquer des dommages mat riels des blessures personnelles ou la mort REMARQUE Les pompes de piscine sup rieures 2 CV peuvent produire des d bits d passant les 348 L min 92 g m Si vous n tes pas certain e du d bit de la pompe de votre piscine communiquez avec votre d taillant pour de l aide Page 54 Le d bit maximum pour la cellule est de 348 L min 92 gpm Si le d bit exc de 348 L min 92 gpm la cellule DOIT tre install e sur la tuyauterie de d rivation Une soupape de contr le doit tre install e pour contr ler le d bit dans la cellule Il peut tre install du c t entr e de la cellule ou entre le c t entr e et le c t refoulement de la tuyauterie de d rivation Le d bit sera rectifi apr s avoir appuy sur la poign e de la soupape jusqu ce que l indicateur rouge Flow s teigne et les grosses boules d air disparaissent dans la cellule R chauffeur Zodiac AquaPure Ei Series APURE35C Guide d installation et
97. rking Pen Phillips Head Screwdriver or Phillips Head Drill Bit 0 4m 1 1 3 ft MIN Figure 3 Installation Requirements Zodiac AquaPure Ei Series APURE35C Installation and Operation Manual 3 3 Installing the Power Pack and Cell WARNING If you are installing the Zodiac AquaPure Ei Series APURE35C to a Goldline adaptor it is necessary to disconnect the power to the Goldline controller Zodiac recommends that any procedure requiring potential contact with live electrical wiring and or parts other than cords and plugs connected to electrical outlets be completed by a contractor who is licensed and qualified in pool equipment as described on the front cover of this manual Failure to follow warning notices and instructions may result in property damage serious injury or death WARNING To avoid property damage serious injury or death do not operate the electrolytic cell without water circulation A buildup of flammable gasses which can result in FIRE OR EXPLOSION Ensure placement of the cell and the power pack will meet all the installation requirements outlined in Section 3 2 2 Screw the power pack bracket into position on a wall surface where it will mount securely while ensuring it is no more than 4 6 m 15 ft from the cell see Figure 4 3 Position the power pack in place by aligning the bracket with the corresponding thru holes see Figure 4 Thru holes Screws
98. s Voir Figure 7 Trous dans le tuyau Figure 9 Fixer le collier de serrage de la cellule 12 Ins rer le joint torique dans le canal sur chacune des pinces et ensuite fixer la cellule Voir Figures 10 et 11 Figure 7 Percer les trous dans le tuyau Saint torique 9 Utiliser l carteur de tuyau tel qu illustr en cas de montage avec un tuyau de 40 mm 1 po Voir Figure 8 Ecarteur utilise seulement pour un tuyau de 40 mm 1 1 2 po Figure 10 Fleches du d bit d eau Figure 8 Ecarteur de tuyau Zodiac AquaPure Ei Series APURE35C La rainure doit se trouver du c t de l entr e Guide d installation et d utilisation Figure 11 Cellule attach e Figure 14 Mise de niveau de l anneau de serrage 13 Aligner correctement l anneau de serrage en s assurant que la bosse soit align e avec la rainure sup rieure Voir Figure 12 15 Aligner la bosse avec la rainure superieure sur la Figure 12 Alignement d anneau de serrage 14 Visser l anneau de serrage au collier de serrage filet l aide de l outil pour anneau de serrage Voir Figure 13 REMARQUE S assurer que l anneau de serrage soit de niveau avant d ins rer la niche de filetage Voir Figure 14 Outil pour anne
99. s en vinyle ou fibre de verre le sel peut tre ajout de la mise en service Tableau 1 Niveau actuel de sel ppm 1 000 Zodiac AquaPure Ei Series APURE35C Guide d installation et d utilisation Nombre approximatif de kilogrammes et de livres de sel n cessaires pour obtenir une concentration de 4 0 gpl 4000 ppm dans la piscine Grandeur de la piscine du spa en litres gallons am ricains 38 000 L 10 000 gal 132 kgs 292 Ibs 123 kgs 271 Ibs 57 000 L 15 000 gal 76 000 L 20 000 gal 199 kgs 438 Ibs 265 kgs 584 Ibs 185 kgs 407 Ibs 246 kgs 542 Ibs 25 000 gal 95 000 L 397 kgs 876 Ibs 369 kgs 814 Ibs 114 000 L 30 000 gal 151 kgs 334 Ibs 227 kgs 501 Ibs 303 kgs 668 Ibs 379 kgs 835 Ibs 454 kgs 1 001 Ibs 142 kgs 313 Ibs 213 kgs 469 Ibs 284 kgs 626 Ibs 355 kgs 782 Ibs 426 kgs 939 Ibs 331 kgs 730 Ibs 308 kgs 678 Ibs 114 kgs 250 Ibs 170 kgs 376 Ibs 227 kgs 501 Ibs 284 kgs 626 Ibs 341 kgs 751 Ibs 156 kos 44 fs 208 kgs 459 TAZ kas 313 fs 180 kos 47 128 kgs 282 170 kas TE bs 114 kgs 250 Ibs 151 kgs 334 Ibs 227 kgs 501 Ibs 182 kgs 2219 18 kgs UE s 3 000 38 kgs 83 Ibs 57 kgs 125 lbs 76 kgs 167 Ibs 95 kgs 209 Ibs 114 kgs 250lbs 2 750 47 kgs 104 Ibs 71 kgs 156 Ibs 95 kgs 209 Ibs 118 kgs 261 Ibs 142 kgs 313 Ibs Tableau 2 132 00
100. s et des piscines avec spa int gr Il ne peut pas tre utilis dans des spas autonomes Tous les travaux d lectricit doivent tre effectu s par un lectricien agr e et doivent se conformer aux normes f d rales provinciales et locales Au cours de l installation et l utilisation de l equipement lectrique des mesures de s curit de base doivent toujours tre respect es y compris les suivantes AVERTISSEMENT QUIPEMENT SOUS PRESSION Toujours teindre la pompe avant d installer ou d effectuer l entretien du bloc d alimentation ou de la cellule La pompe et le filtre op rent sous pression et la pression doit tre relach e avant de commencer le travail Veuillez consulter le manuel d utilisateur de votre pompe filtre pour plus d instructions AVERTISSEMENT Les chlorateurs Zodiac AquaPure Ei Series APURE35C sont con us pour l usage dans les piscines r sidentielles seulement L utilisation non conforme aux consignes pourrait nuire au fonctionnement annuler la garantie et causer des dommages mat riels des blessures graves ou la mort Les piscines ou spas utilisation fr quente et les temp ratures plus lev es peuvent exiger de chlorer davantage afin de maintenir une quantit appropri e de r sidus de chlore brome L utilisation du chlorateur sans qu il y ait d bit d eau dans la cellule lectrolytique pourrait causer une accumulation de gaz inflammables qui pourrait causer un INCENDIE ou une
101. t le bloc d alimentation peut tre bloqu dans AquaLink Pour v rifier si le type de r gulateur est r gl correctement 1 Mettre en marche le bloc d alimentation 2 Attendre jusqu la s quence de la mise en marche soit compl t e 3 Appuyer et tenir enfonc le bouton OUTPUT production pendant environ quatre 4 secondes Apr s quatre 4 secondes un type de dispositif de commande sera affich sur l cran 4 V rifier que le type de r gulateur JANDY L M est affich Si le type de r gulateur n est pas r gl sur JANDY L M garder le bouton OUTPUT production enfonc pour faire d filer la liste des r gulateurs Chaque dispositif de commande sera affich sur l cran pendant deux 2 secondes Rel cher le bouton OUTPUT production lorsque JANDY L M est affich Page 52 3 6 2 C blage un syst me de commande d AquaLink RS ou PDA AVERTISSEMENT POUR VOTRE S CURIT le pr sent produit doit tre install et maintenu par un technicien professionnel sp cialis dans l installation et la maintenance des piscines et des spas tel qu il est d crit sur la page couverture du pr sent manuel Les consignes de ce manuel doivent tre suivies scrupuleusement Toute infraction aux consignes de s curit et d emploi pourrait causer des dommages mat riels des blessures graves ou m me la mort L installation ou l utilisation inappropri e annulera la garantie Lors de l u
102. t pour remplacer la cellule pendant l hivernisation ou l entretien de la cellule Cela permettra la pompe de la piscine de faire circuler l eau avec la cellule en d viation Durant la saison froide si vous utilisez un R GULATEUR DE GEL sur l quipement de la pompe et que choisissiez de laisser le chlorateur install diminuer la PRODUCTION DE CHLORE 20 autrement la production de chlore d passera le niveau recommand de 1 3 ppm 6 4 1 Pr paration pour l hiver AVERTISSEMENT Avant d effectuer ces t ches couper l alimentation au niveau du panneau principal disjoncteurs pour viter le risque de choc lectrique pouvant entra ner des dommages mat riels des blessures graves ou la mort 1 S assurer que l alimentation vers le bloc d alimentation et le syst me de commande a t coup e ou teinte au niveau du disjoncteur 2 Fermer toutes les soupapes n cessaires pour pr venir des pertes d eau 3 Ouvrir le robinet purgeur d air pour lib rer la pression dans le syst me de la piscine Zodiac AquaPure Ei Series APURE35C Guide d installation et d utilisation 4 Retirer le capuchon terminal et les fils de sortie de la cellule 5 Retirer l anneau de serrage Si n cessaire utiliser l outil pour anneau de serrage fourni Voir Figure 25 6 Retirer la cellule Voir Figure 26 7 Fixer le bouchon d hivernisation Voir Figure 27 Figure 28 Bouchon d hivernisa
103. tes examiner un chantillon de l eau de votre piscine par un professionnel Faites les ajustements requis pour maintenir le niveau de duret calcique entre 200 et 300 ppm voir Section 4 3 Entretien mensuel V rifier la cellule Il est recommand d enlever la cellule tous les mois et d examiner la formation de tartre ou de d bris Si la cellule doit tre nettoy e voir Section 6 3 pour les instructions Test de niveau de salinit Utiliser des bandelettes pour tests de salinit un compteur de salinit mati res totales dissoutes ou toute autre m thode s re pour tester la salinit de l eau de piscine Une fois que le taux existant de salinit a t d termin utiliser le tableau 1 pour d terminer quelle quantit de sel ajouter pour atteindre le niveau d sir Soyez prudent lorsque vous ajoutez du sel parce qu il est plus facile d ajouter plus de sel que de diluer s il y en a trop Si le niveau de salinit de la piscine est appropri et l indicateur DEL de sel ne s teigne pas voir Section 7 D pannage chantillon d eau de piscine Apporter un chantillon d eau un magasin de piscine de votre r gion pour effectuer le test Stabilisateur Acide cyanurique Tester le niveau du stabilisateur de l eau de la piscine niveau de l acide cyanurique en utilisant une trousse d analyse ou en faisant tester un chantillon d eau par un professionnel en piscine Conserver un niveau recomman
104. the controller type must be set to JANDY L M to allow communication between the power pack and the AquaLink RS Control System The default controller setting on the power pack is JANDY L M Follow the instructions below to verify the controller type is set correctly NOTE The controller type must be set correctly before making the wiring connection between the power pack and the AquaLink otherwise the power pack may be locked out of the AquaLink To verify the controller type is set correctly 1 Apply power to the power pack 2 Wait for the start up sequence to complete 3 Press and hold the OUTPUT button for approximately four 4 seconds After four 4 seconds a controller type will be displayed on the screen 4 Verify that the JANDY L M controller type appears on the display If the controller type is not set to JANDY L M keep the OUTPUT button pressed to toggle through the list of controllers Each controller will be displayed on the screen for two 2 seconds Release the OUTPUT button when JANDY L M appears on the display Page 16 ENGLISH Zodiac AquaP ure Ei Series APURE35C Installation and Operation Manual 3 6 2 Wiring to the AquaLink RS Control System or PDA FOR YOUR SAFETY This product must be installed and serviced by a professional pool spa service technician as described on the front cover of this manual The procedures in this manual must be followed exactly Failure to follow warning not
105. the top thread 9 Screw down the locking ring to the threaded clamp using the locking ring tool NOTE Ensure the locking ring is level when engaging the threading housing see Figure 29 Figure 29 Locking Ring Level Zodiac AquaPure Ei Series APURE 35C Section 7 Troubleshooting WARNING Installation and Operation Manual Page 29 Always turn pump off prior to attempting service or repair Your pump and filter system is operated under pressure and pressure must be released before you begin to avoid system damage or personal injury Follow the manufacturer s instructions to properly release the air in the pool filter Problem Possible Cause Corrective Action Low or no chlorine Low stabilizer cyanuric acid level in pool water for outdoor pools only Add stabilizer to maintain 10 50 ppm see Table 2 Insufficient operating hours of the unit Increase the system operating time per day Chlorine output percentage set too low Increase chlorine production by pressing the Output button see Section 5 4 Recent increases in weather temperature without increasing the chlorine production of your unit Increase chlorine production by pressing the Output button see Section 5 4 Temporary loss of chlorine due to heavy organic load rain leaves fertilizer or heavy bather load Pets using pool
106. tilisation de produits lectriques des pr cautions de base doivent toujours tre suivies entre autres DANGER RISQUE DE CHOC LECTRIQUE POUVANT CAUSER DES BLESSURES GRAVES OU LA MORT Avant de tenter d installer ou d entretenir le mat riel s assurer que l alimentation lectrique alimentant tout appareil a t d branch e ou teinte au niveau du disjoncteur Brancher seulement un circuit prot g par un disjoncteur de fuite la terre La mise la terre est requise Lappareil doit tre install par un repr sentant de service qualifi et tre correctement mis la terre Voir Section 3 4 C blage du bloc d alimentation la source de courant Lors de l installation laisser un espace d acc s pour l entretien de l appareil Veuillez lire toutes les instructions et consignes de s curit dans la section Instructions de s curit importantes Avant d effectuer tout cablage lectrique s assurer de lire et de suivre toutes les consignes de s curit Le cablage doit tre fait uniquement par un technicien qualifi 1 S assurer que l alimentation vers le bloc d alimentation et le syst me de commande a t coup e ou teinte au niveau du disjoncteur 2 Enlever les vis qui fixent le couvercle la plaque arri re et soulever le couvercle pour d gager les bornes Voir Figure 18 REMARQUE Faire attention de ne pas tirer sur le c ble plat qui est connect la source d alimentation
107. tion install 8 Aligner correctement l anneau de serrage en s assurant que la bosse soit align e avec la rainure sup rieure 9 Visser l anneau de blocage au collier de serrage filet l aide de l outil pour l anneau de serrage REMARQUE S assurer que l anneau de serrage soit de niveau avant d ins rer le boitier de filetage Voir Figure 29 Figure 29 Mise au niveau de l anneau de serrage Zodiac AquaPure Ei Series APURE35C Section 7 D pannage Guide d installation et d utilisation AVERTISSEMENT Toujours teindre la pompe avant d effectuer l entretien ou des reparations La pompe et le filtre op rent sous pression et il doit y avoir d tente de cette pression avant de commencer le travail pour viter des dommages au syst me ou des blessures personnelles Ouvrir la soupape de d gagement d air de votre filtre de piscine pour lib rer la pression dans le syst me Probl me Cause possible Action Corrective Peu ou pas de chlore Faible concentration de stabilisateur acide cyanurique dans l eau de la piscine pour piscine ext rieures seulement Heures de fonctionnement de l appareil inad quates Ajouter le stabilisateur pour maintenir une concentration de 10 50 ppm Voir Tableau 2 Augmenter la dur e quotidienne du fonctionnement du syst me Production du chlore r gl e un niveau
108. uer avec un professionnel en piscine Nouvelle eau de piscine Chloration choc initiale inad quate Surchloriner la piscine Cellule obstru e ou sale Retirer la cellule pour l inspecter et nettoyer si n cessaire Voir Section 6 3 Probl me Cause possible Action Corrective Niveau de chlore trop lev Production du chlore r gl e un niveau trop lev Diminuer le taux de production de chlore l aide du bouton de production Voir Section 5 4 Le bloc d alimentation et la cellule ont t allum s pendant trop long temps Si la production de chlore est r gl e au minimum et que le niveau de chlore est r guli rement trop lev diminuer la dur e de temps pendant laquelle la pompe fonctionne chaque jour tel que n cessaire Page 66 Zodiac AquaP ure Ei Series APURE35C Guide d installation et d utilisation Probl me Cause possible Action Corrective Rien n est affich l cran affichage a cristaux liquides ACL L cran est vide Aucune alimentation au syst me V rifier la connexion la minuterie de la pompe Voir Section 3 4 V rifier si le disjoncteur de la mise la terre est d clench Probl me Cause possible Action Corrective Lindicateur de d bit est allum et affiche No Flow pas de d bit Caus par un d bit d eau insuffisant dans la cellule REMARQUE Lorsque l indi
109. unit Check the connection to the pump timer see Section 3 4 Check if GFCI tripped Problem Possible Cause Corrective Action Flow light is on Display says No Flow Caused by insufficient water flow through the cell NOTE When the Flow light is on the chlorine output will be The pump or skimmer baskets are filled with debris preventing sufficient water flow through the system Check and clean the pump and skimmer baskets turned off Dirty filter Clean the filter Closed valves Check and correct all valve alignments Pump fails to provide Check for correct operation of the sufficient water flow pump Make sure pump is sized properly for required flow rate Problem Possible Cause Corrective Action Salt light is on and the display says Check Salt or Low Temperature NOTE The Salt light will turn on when the salt level drops well below 3 000 ppm and it will remain on until the salt level is raised above 4 000 ppm If an AquaLink RS or PDA is installed when the salt level is low the AquaLink RS or PDA will display Salt 2900 PPM Check AquaPure Low Salt Salt level is well below 3 000 ppm depending on water temperature Maintain a salinity level of 4 000 ppm 4 500 ppm see Section 4 6 or contact your local pool professional Cell life expired Replace the cell Problem Possible Cause Corrective Action D
110. up of by products can damage the electrolytic cell NOTE Total Alkalinity Test Test pool water for total alkalinity with a test kit Take steps necessary to maintain an alkalinity of 100 120 ppm see Section 4 3 Calcium Hardness Test pool water for calcium hardness level using test kit or by having a water sample tested by a pool professional Adjust as necessary to maintain a calcium hardness of 200 300 ppm see Section 4 3 Monthly Check the cell It is recommended that every month the cell be removed and inspected for scale formation and or debris If cell needs to be cleaned see Section 6 3 for instructions Salt Level Test Use salinity test strips a TDS salinity meter or another reliable method to test the salinity of the pool water Once the existing salinity has been established use Table 1 to determine the amount of salt to add to reach the desired level Be conservative when adding salt as it is easier to add more if needed than it is to dilute if there is too much salt If the salinity level of the pool is correct and the salt LED does not go out see Section 7 Troubleshooting Pool Water Sample Take water sample to local pool store for testing Stabilizer Cyanuric Acid Test pool water stabilizer cyanuric acid level using a test kit or by having a water sample tested by a pool professional Maintain ideal range of 10 50 ppm Follow your pool professionals recommendations For indoor pools
111. use a buildup of flammable gases which can result in FIRE OR EXPLOSION KEEP OUT OF REACH OF CHILDREN Page 2 ENGLISH Zodiac AquaP ure Ei Series APURE35C Installation and Operation Manual Notice to User This pest control product is to be used only in accordance with the directions on the label It is an offence under the Pest Control Products Act to use this product in a way that is inconsistent with the directions on the label The user assumes the risk to persons or property that arises from any such use of this product e Maximum Overcurrent Protection 15A Use Copper Conductors Only e Disconnect Power before Opening Service Cover For Outdoor or Indoor Use Electrical Requirements 120 240 VAC 50 60 Hz 3 WIRE 1 3 AMP Maximum Output of Hypochlorous Acid is Equivalent to 420 g of Free Available Chlorine Per Day 4 000 parts per million of salt The maximum volume of water that can be treated with one unit of APURE35C is 132 000 litres 35 000 gallons 132 0 m3 For swimming pools a range of 1 3 ppm of free available chlorine must be maintained Controls bacteria and algae in swimming pool water Zodiac AquaPure Ei Series APURE35C Installation and Operation Manual Page 3 Table of Contents Section 1 Important Safety Instructions 5 Section 2 System Description 8 2 1 Product Specifications Zodiac AquaPure Ei Series APURE35C eeeceesseeeeeeeeeeeteeeeeneeeeee 8 2 2 Product