Home

6,500W Gasoline Generator

image

Contents

1. 1 Carefully remove the parts and accessories from the packaging Retain packaging material until you have carefully inspected and satisfactorily installed or operated the generator 2 Inspect the engine carefully to make sure the generator was not damaged during shipping WARNING If any parts are missing do not operate the engine until the missing parts are replaced Failure to do so could result in a malfunction and serious personal injury PARTS IDENTIFICATION C Fuel Tank Cap Fuel Tank Handle Choke Rod Air Cleaner Recoil Starter Frame Oil Drain Plug Dipstick Wheel Control Panel RATIO NNMOOX gt Visit www princessauto com for more information 5 V 3 04 6 500W Gasoline Generator 8254146 ENGINE KEY To start and stop the engine Key position On To run the engine after starting O OFF To stop the engine The Key can be removed inserted Recoil Starter To start the engine lightly pull the starter grip until resistance is felt then pull briskly WARNING Do not allow the starter grip to snap back against the engine Return it gently to prevent damage to the starter When starting the engine by recoil starter set the key switch to the ON position and pull the starter handle FUEL VALVE LEVER The fuel valve is located between the fuel tank and the carburetor When the valve lever is in the ON position fuel is allowed to flow from the fuel tank to the carburetor Be sure to retur
2. AVERTISSEMENT Un entretien inad quat ou le d faut de corriger un probl me avant l utilisation peut entrainer une d fectuosit capable d entrainer des blessures graves et m me la mort 12 En cas de questions techniques appelez le 1 800 665 8685 8254146 G n rateur essence 6 500 W V 3 04 S CURIT PENDANT L ENTRETIEN Assurez vous que le moteur soit teint avant de commencer les travaux d entretien ou de r paration 7 Laissez le moteur et le systeme d chappement refroidir avant de le toucher 3 Afin de r duire les possibilit s d incendie ou d explosion prenez garde lorsque vous travaillez a proximit d essence Utilisez un solvant ininflammable et non pas de l essence pour nettoyer les pi ces Ne fumez pas et loignez les sources d tincelles et de flammes de toutes les pi ces se rapportant l essence PROGRAMME D ENTRETIEN Rappelez vous que ce programme d entretien repose sur l hypoth se selon laquelle vous utiliserez votre appareil aux fins pour lesquelles il a t concu Un fonctionnement avec une charge ou une temp rature lev e soutenue ou l utilisation dans des conditions particulierement humides ou poussi reuses demandera un entretien plus fr quent P riode d entretien normale Avant Premier mois Tousles3 Tous les Tous les chaque ou les mois ou 6 mois ou ans ou 300 Effectu chaque moi
3. If it still does not fit contact a qualified electrician to install a polarized outlet Do not change the plug in any way Double insulation eliminates the need for a three wire grounded power cord and grounded power supply system 4 Grounded tools must be plugged into an outlet that is properly installed and grounded in accordance with all codes and ordinances Never remove the grounding prong or modify the plug in any way Do not use any adapter plugs Check with a qualified electrician if you are in doubt as to whether the outlet is properly grounded If the tool should electronically malfunction or break down grounding provides a low resistance path to carry electricity away from the user 4 For technical questions call 1 800 665 8685 8254146 6 500W Gasoline Generator V 3 04 5 Do not abuse the cord Never use the cord to carry tools or to pull the plug from an outlet Keep the cord away from heat oil sharp edges or moving parts Do not operate this tool if the power cord is frayed or damaged Immediately replace damaged cords Damaged cords increase the risk of electrical shock Do not modify the plug in any way 6 When operating a power tool outside use an outdoor extension cord marked W A or W These cords are rated for outdoor use and reduce the risk of electrical shock Use in conjunction with a Ground Fault Circuit Interrupter GFCI If operating a power tool in a damp location is unavoidable the use of a GFCI reduces the ri
4. carburateur S il y a longtemps que le moteur n a pas fonctionn on recommande de nettoyer le bac de s dimentation 1 Tournez le levier du robinet de carburant en position OFF arr t Enlevez le bac de s dimentation le joint torique et le filtre 2 Nettoyez le bac de s dimentation le joint torique et le filtre dans un solvant ininflammable ou pr sentant un point d inflammabilit lev 3 R installez le filtre le joint torique et le bac de s dimentation 4 Tournez le levier de robinet de carburant en position de marche et v rifiez s il y a des fuites ENTRETIEN DES BOUGIES Pour assurer un fonctionnement ad quat du moteur il est important que la Fig 14 bougie respecte la distance d cartement prescrite et qu elle soit exempte 0 023 0 031in de d p ts Le silencieux sera tr s chaud si le moteur tait en marche t 0 70 0 80 mm Prenez soin de ne pas toucher le silencieux 1 Retirez le bouchon de la bougie 2 Eliminez toute salet autour de la base de la bougie 3 Retirez la bougie au moyen d une cl bougie 4 Inspectez visuellement la bougie Jetez la bougie si l isolant est fissur br ch ou encrass 5 Mesurez l cartement des lectrodes au moyen d une jauge d paisseur Corrigez cet cart si n cessaire en courbant doucement le c t de l lectrode REMARQUE L cart devrait mesurer De 0 028 po 0 031 0 70 0 80 mm 6 V rifiez si la rondelle de bo
5. difficile Le fonctionnement prolong une altitude diff rente de celle laquelle on a certifi le moteur peut accroitre la quantit d missions Certaines modifications pr cises au niveau du carburateur peuvent am liorer le rendement haute altitude Si vous utilisez toujours votre moteur des altitudes sup rieures 1 500 m 5 000 pi demandez un technicien de service qualifi de proc der cette modification du carburateur Lorsqu il est utilis haute altitude alors que le carburateur a t modifi en cons quence ce moteur doit r pondre toutes les normes relatives aux missions tout au long de sa dur e de vie utile M me si on modifie le carburateur la puissance du moteur diminuera d environ 3 5 tous les 300 m 1 000 pi d augmentation d altitude L effet de l altitude sur la puissance sera plus prononc si on ne proc de aucune modification du carburateur AVERTISSEMENT Lorsqu on a modifi le carburateur pour l utiliser en haute altitude le m lange d air carburant sera trop faible pour une utilisation en basse altitude Le fonctionnement des altitudes inf rieures 1500 m 5 000 pi avec un carburateur modifi peut entrainer la surchauffe du moteur et des dommages graves au niveau du moteur ENTRETIEN Un entretien ad quat est essentiel pour assurer un fonctionnement s curitaire conomique et sans probl me De plus un tel entretien contribuera r duire la pollution atmosph rique
6. huile us e ENTRETIEN DU FILTRE A AIR Un filtre air sale aura pour effet de limiter le d bit d air en direction du carburateur Pour emp cher toute d fectuosit du carburateur proc dez un entretien r gulier du filtre air Effectuez un entretien plus fr quent si vous utilisez le g n rateur dans des endroits tr s poussi reux AVERTISSEMENT Ne faites jamais fonctionner le g n rateur s il n est pas muni du filtre air Il en r sultera une usure rapide du moteur 1 Retirez les pinces du couvercle du filtre air retirez le filtre air et retirez l l ment Lavez l l ment du filtre air dans une solution de d tergent et d eau chaude puis rincez bien ou lavez dans un solvant non inflammable ou point d clair lev Laissez l l ment du filtre air s cher compl tement 3 Trempez l l ment du filtre air dans de l huile moteur propre et essorez l huile en exc s Le moteur d gagera de la fum e lors du d marrage initial s il reste trop d huile l int rieur de l l ment du filtre air 4 R installez l l ment du filtre air et le couvercle ae LL M Couvercle du filtre a air 14 En cas de questions techniques appelez le 1 800 665 8685 8254146 G n rateur a essence 6 500 W V 3 04 NETTOYAGE DU BAC DE SEDIMENTATION DE CARBURANT Le bac de s dimentation emp che la salet ou l eau pouvant se trouver l int rieur du r servoir de carburant de p n trer dans le
7. muffler will be very hot Allow it to cool before proceeding WARNING The spark arrester must be serviced every 100 hours to maintain its efficiency Clean the spark arrester as follows 1 Loosen the screw next to the exhaust port of the muffler and remove the spark arrester 2 Usea brush to remove carbon deposits from the spark arrester screen Inspect the screen for breaks or tears and replace it if necessary 3 Install the spark arrester in the reverse order of removal 14 For technical questions call 1 800 665 8685 8254146 STORAGE 6 500W Gasoline Generator V 3 04 Before storing the unit for an extended period 1 Be sure the storage area is free from excessive humidity and dust 2 Service according to the following table Storage Time Less than 1 month To Prevent Hard Starting Recommended Service Procedure No preparation required 1 to 2 months Fill with fresh gasoline and add gasoline conditioner 2 months to 1 year Fill with fresh gasoline and add gasoline conditioner Drain the carburetor float bowl Drain the fuel sediment cup 1 year or more Fill with fresh gasoline and add gasoline conditioner Drain the carburetor float bowl Drain the fuel sediment cup Remove the spark plug and put a tablespoon of engine oil into the cylinder head Pull the recoil starter slowly to distribute the oil evenly in the cylinder Reinstall the spark plug Change the engine oil After removal from stora
8. ou sous l effet de drogues d alcool ou de m dicaments c N utilisez pas le moteur si vous devez tirer les bras pour vous en servir Une stabilit et un quilibre appropri s permettent d avoir un meilleur contr le de l quipement en cas de situations inattendues CONSIGNES DE S CURIT SP CIFIQUES AVERTISSEMENT Ce g n rateur produit suffisamment de courant pour causer un choc lectrique ou une lectrocution grave s il est utilis de mani re inad quate 1 Tous les utilisateurs doivent comprendre le fonctionnement de toutes les commandes et savoir comment arr ter le g n rateur rapidement en cas d urgence Il est important de comprendre la facon d utiliser toutes les commandes les prises de sortie et les connexions du g n rateur 2 Sile g n rateur est remis l ext rieur et non l abri des intemp ries v rifiez tous les composants lectriques sur le tableau de commande avant chaque utilisation l humidit ou la glace peut entra ner une d fectuosit ou un court circuit au niveau des composants lectriques ce qui risque de provoquer une lectrocution 3 Ne branchez pas le g n rateur au syst me lectrique d un difice moins qu un lectricien comp tent n ait install un commutateur isol 4 Toutes les op rations d entretien et d installation des circuits doivent tre confi es un professionnel de service comp tent en plus de r pondre toutes les normes en vigueur Visitez www princes
9. renverser de carburant Ne remplissez pas au dessus du rebord de la cr pine de carburant AVERTISSEMENT L essence s enflamme et explose tr s facilement de sorte que vous risquez d tre br l ou s rieusement bless lorsque vous proc dez au remplissage Coupez le moteur et loignez de celui ci toutes les sources de chaleur d tincelles et de flammes Proc dez au remplissage l ext rieur seulement 5 Utilisez de l essence sans plomb avec un taux d octane la pompe d au moins 86 Le moteur est certifi indiquant qu il utilise l essence sans plomb pepe Jauge de carburant REMARQUE L essence sans plomb produit moins de d p ts dans le moteur et sur les bougies et prolonge la dur e de vie du syst me d chappement N utilisez jamais d essence ancienne ou contamin e ni un m lange d huile et d essence Evitez de mettre des salet s ou de l eau dans le r servoir de carburant D MARRAGE ARR T DU MOTEUR DEMARRAGE DU MOTEUR Assurez vous que le disjoncteur c a est en position OFF arr t Il peut tre difficile de d marrer le g n rateur si une charge est d branch e 2 Tournez le levier de robinet de carburant en position ON marche 3 L trangleur sera ferm si le moteur est froid Tirez sur la tige d trangleur afin de quitter la position ferm e 4 Mettez l interrupteur du moteur en position marche 5 Tirez la poign e du d marreur lentement jusqu ce que vous sentiez une r sistance pu
10. risque de choc lectrique Il est recommand que le disjoncteur de fuite la terre poss de un courant r siduel nominal de 30 mA ou moins 7 Evitez d utiliser une rallonge excessivement longue Choisissez une rallonge appropri e la situation car une rallonge trop longue qui tra ne sur le plancher peut tre plus dangereuse qu utile L usage d une rallonge trop longue ou trop mince peut endommager l outil D roulez la rallonge au complet pour l emp cher de surchauffer 8 Disposez le cordon lectrique de facon qu il ne touche pas l outil et qu il ne risque pas de se prendre dans la pi ce travailler Le cordon doit toujours se trouver derri re l outil PRECAUTIONS RELATIVES A LA PILE Tenez la batterie l cart du feu et des tincelles Renforcez les c bles de mise la masse et de descente 2 La batterie contient un acide puissant vitez tout contact avec la peau et les yeux En cas de contact lavez vous la peau ou rincez vous les yeux imm diatement avec de l eau Consultez un m decin en cas de probl me grave 3 vitez de d verser de l essence de l huile ou une mati re organique sur la batterie puisque celle ci subira alors des dommages UTILISATION ET ENTRETIEN Ce g n rateur a t concu pour une utilisation sp cifique Ne modifiez ou n alt rez pas ce g n rateur ou ne l utilisez pas une fin autre que celle pour laquelle il a t concu a Netrafiquez pas le ressort de r gulateur les tringles ou
11. 10 For technical questions call 1 800 665 8685 8254146 6 500W Gasoline Generator V 3 04 OPERATION CONNECTIONS TO A BUILDING ELECTRICAL SYSTEM A qualified electrician must perform connections for standby power to a building s electrical system The connection must isolate the generator power from the utility power and must comply with all applicable laws and electrical codes A transfer switch which isolates generator power from utility power is required WARNING Improper connections to a building s electrical system can allow electrical current from the generator to back feed into the utility lines Such back feed may electrocute utility company workers or others who contact the lines during a power outage and the generator may explode burn or cause fires when utility power is restored Consult the utility company or a qualified electrician GROUND SYSTEM The portable generator has a system ground that connects the generator frame components to the ground terminals in the AC output receptacles The system ground is not connected to the AC neutral wire AC APPLICATIONS Before connecting an appliance or power cord to the generator 1 Make sure that it is in good working order Faulty appliances or power cords can create the potential for electrical shock 2 Ifan appliance operates abnormally becomes sluggish or stops suddenly immediately turn off the appliance Disconnect the appliance and determine whether the problem is with the
12. Disconnect the DC battery charging cables 2 Turn the engine switch to the O OFF position 3 Turn the fuel valve lever to the OFF position INTELLIGENCE PROTECT SWITCH 1 When the load reaches the rated power the indicator light turns green 2 When the load reaches the maximum power the indicator light turns red and the buzzer sounds 3 When the load exceeds the maximum power for 1 minute it automatically switches off the output 4 Press the reset switch to make the generator work again AUTOMATIC GENERATOR SYSTEM AGS After installation be sure the machine is not overloaded If the electricity goes out the generator will cut off the outside circuit and will automatically start generating When the outside power is restored the generator will automatically switch off and the outside circuit will automatically connect Fuel Level WARNING If the generator will not start check whether the lis S asp Een indicator glitters when starting the machine Add oil if the Qu indicator glitters 1 Besure the load won t be over loaded then install the generator Engine Number 2 Usually the AGS switch on the control panel will be in the automatic position and the key in the running position 3 Move the choke switch to the OPEN position ALARM SYSTEM The indicator light will come on when you start the generator if the oil is at an insufficient level The indicator light will go off when the oil level is sufficient
13. Gfelow Green Ignition Switch Connection Lo orange i Brown Rea pn lacie fa rea fu wore __ Noel pes ors oto edo o LET Ber TTC 17 Visitez www princessauto com pour plus d informations
14. NTENANCE SCHEDULE Maintenance schedules are based on the assumption that your machine will be used for its designed purpose Continuous high load or high temperature operation or use in unusually wet or dusty conditions will necessitate more frequent service Regular Service Period Before Each First Every 3 Every 6 months Every Year or o Use Month or months or 50 or 300 Hours Performed at every indicated month 20 Hours Hours 100 Hours or operating hour interval whichever comes first Engine Oil Check X Change X X Air Cleaner Check X Clean AUS Sediment Cup Clean X Spark Plug Clean X Adjust Replace X Spark Arrestor Clean X Idle Speed Check X Adjust Valve Clearance Check X Adjust Combustion Chamber Clean After every 500 Hours Fuel Tank and Filter Clean X Fuel Tube Check Every 2 years replace if necessary For commercial use log hours of operation to determine proper maintenance intervals Service more frequently when used in dusty areas 12 For technical questions call 1 800 665 8685 8254146 6 500W Gasoline Generator V 3 04 j Oil Drain Plug ENGINE OIL CHANGE Drain the oil while the engine is warm to ensure rapid and complete draining 1 Remove the drain plug and sealing washer remove the oil filler cap and drain the oil 2 Reinstall the drain plug and sealing washer Tighten the plug securely 3 Refill with the recommended oil and ch
15. PEL Pour d marrer le moteur tirez la poign e du d marreur lentement jusqu ce que vous sentiez une r sistance puis tirez soudainement AVERTISSEMENT vitez que la poign e du d marreur ne revienne en frappant le moteur Faites le fonctionner doucement pour viter les dommages au niveau du d marreur Lorsque vous d marrez le moteur au moyen d un lanceur rappel placez l interrupteur cl la position marche et tirez sur la poign e du d marreur LEVIER DE ROBINET DE CARBURANT ig Dader A anie Le robinet de carburant se trouve entre le r servoir de carburant et le P wen c qq carburateur Lorsque le levier de soupape se trouve la position ON marche le carburant peut s couler du r servoir de carburant en direction z du carburateur Assurez vous de ramener le levier du robinet de carburant la position OFF arr t apr s avoir arr t le moteur TIGE D ETRANGLEUR Cet trangleur a pour but de produire un m lange de carburant enrichi lorsque vous d marrez un moteur froid Vous pouvez l ouvrir et le fermer en actionnant manuellement la tige d trangleur Sortez la tige en la tirant vers la position ferm pour enrichir le m lange en vue de proc der un d marrage froid 6 En cas de questions techniques appelez le 1 800 665 8685 8254146 G n rateur a essence 6 500 W V 3 04 BORNE DE MISE A LA MASSE La borne de mise la masse du g n rateur est reli e a
16. V 3 04 8254146 User Manual Please read and understand all instructions before use Retain this manual for future reference V 3 04 8254146 FIST SPECIFICATIONS Receptacles One 120 240V Twist Lock One 12V Four 120V Max Output 6 500 watts Continuous Output 5 500 watts Engine Displacement 389 cubic centimeters Fuel Type Gasoline Recoil Start Yes Electric Start No Tank Capacity 25 litres 6 6 gallons Run Time 50 Load 11 hours Hour Meter No Operating Noise 74 decibels Low Oil Shutdown Yes GFCI Protection No Battery Included No Remote Included No Tire Size 10 inches INTRODUCTION The 6 500W generator provides electricity on the job site or back up power for your home or cottage A sturdy designed heavy duty roll cage and 10 in pneumatic wheels provides easy mobility IMPORTANT SAFETY PRECAUTIONS WARNING Read and understand all instructions before using this generator The operator must follow basic precautions to reduce the risk of personal injury and or damage to the equipment Before allowing someone else to use this generator make sure they are aware of all safety information WARNING The warnings cautions and instructions discussed in this instruction manual cannot cover all possible conditions and situations that may occur Common sense and caution are factors that cannot be built into this product but must be supp
17. al wattage PRE OPERATION CHECK WHEEL KIT AND HANDLE INSTALLATION 1 Secure the two wheels and the two handles to the generator with bolts and nuts 2 Before starting the generator apply the wheel and handle locking system to prevent displacement during operation ENGINE OIL WARNING Engine oil is a major factor affecting engine performance and service life Non detergent and 2 stroke engine oils will damage the engine and are not recommended 1 Check the oil level BEFORE EACH USE with the generator on a flat level surface and with the engine stopped 2 Use 4 stroke motor oil that meets or exceeds the requirements for API service classification SJ NOTE Always check the API service label on the oil container to be sure it includes the letters SJ 3 SAE 10W 30 is recommended for general all temperature use Other viscosities shown in figure 6 may be used when the average temperature in your area is within the indicated range 8 For technical questions call 1 800 665 8685 8254146 6 500W Gasoline Generator V 3 04 CHECKING OIL LEVEL 1 Remove the oil filler cap and wipe the dipstick clean 2 Check the oil level by inserting the dipstick into the filler neck without screwing it in 3 If the level is low fill to the top of the oil filler neck with the recommended oil Fig 3 Oil Filler Cap Fig 5 Oil Filer BN SAE Viscosity Grades Ambient Temperature FUEL 1 Check the fuel gauge and refill the tank if the fu
18. and other equipment during operation b Remove accumulated debris from the muffler and cylinder area Combustible debris such as leaves grass brush etc can catch fire if they come in to contact with a hot engine Do not place anything on the generator while it is running d Allow the muffler engine cylinder and fins to cool before allowing the unit to touch grass covered or brush covered unimproved land p peU Visit www princessauto com for more information 3 V 3 04 6 500W Gasoline Generator 8254146 e Gasoline is extremely flammable and is explosive under certain conditions Do not smoke or allow flames or sparks where the generator is refueled or where gasoline is stored Refuel in a well ventilated area with the engine stopped f Fuel vapours are extremely flammable and may ignite after the engine has started Make sure that any spilled fuel has been wiped up before starting the generator 6 Do not let children operate the generator and do not let anyone who is unfamiliar with the generator to operate it without proper supervision 7 Never remove the warning labels Generators provide safe and dependable service if operated according to instructions Read and understand the owner s manual before operating your generator You can help prevent accidents by being familiar NOTE Safety labels warn you of potential hazards that can cause serious injury Read them carefully Contact Princess Auto if a label comes off or beco
19. appliance or if the rated load capacity of the generator has been exceeded 3 Make sure that the electrical rating of the tool or appliance does not exceed the rating of the generator Never exceed the maximum power rating of the generator Do not operate a tool or an appliance at the maximum power rating for more than 30 minutes at a time WARNING Substantial overloading will open the circuit breaker Exceeding the maximum power time limit or slightly overloading the generator may not switch OFF the circuit breaker but it may shorten the service life of your generator AC OPERATION 1 Start the engine 2 Switch ON the AC circuit breaker 3 Plug in the appliance Most motorized appliances require more than their rated power for startup Do not exceed the current limit specified for any one receptacle If an overloaded circuit causes the AC circuit breaker or AC circuit protector to switch OFF reduce the electrical load on the circuit wait a few minutes and then reset the AC circuit breaker or the AC circuit protector HIGH ALTITUDE OPERATION At high altitude the standard carburetor air fuel mixture will be too rich Performance will decrease and fuel consumption will increase A very rich mixture will also foul the spark plug and cause hard starting High altitude operation may also increase emissions however high altitude performance can be improved by specific carburetor modifications If you always operate your generator at alt
20. cilite la mobilit CONSIGNES DE S CURIT IMPORTANTES AVERTISSEMENT Lisez et assurez vous de comprendre toutes les instructions avant d utiliser ce g n rateur L utilisateur doit respecter les pr cautions de base lorsqu il utilise cet outil afin de r duire le risque de blessure ou de dommage l quipement Avant de permettre quelqu un d autre d utiliser ce g n rateur assurez vous que cet individu connait toutes les consignes de s curit AVERTISSEMENT Les avertissements les mises en garde et les instructions mentionn s dans ce manuel d instructions ne peuvent couvrir toutes les conditions et situations pouvant se produire L op rateur doit faire preuve de bon sens et prendre toutes les pr cautions n cessaires afin d utiliser l outil en toute s curit REMARQUE Conservez ce manuel qui contient les avertissements de s curit les pr cautions les instructions de fonctionnement d inspection et d entretien 2 En cas de questions techniques appelez le 1 800 665 8685 8254146 G n rateur essence 6 500 W V 3 04 ae DE TRAVAIL Travaillez dans un environnement de travail s curitaire Gardez votre aire de travail propre et bien clair e N utilisez pas d outils lectriques en pr sence de gaz ou de liquides inflammables a N utilisez pas de liquides de d marrage sous pression avec le g n rateur puisque les manations sont inflammables 3 Assurez vous que les personnes qui ne portent pas l qu
21. clothing jewelry hair etc away from moving parts to avoid entanglement with the engine Traumatic amputation or severe laceration could result b Do not operate any tool or machine when tired or under the influence of drugs alcohol or medications c Do not overreach when operating the engine Proper footing and balance enables better control of equipment in unexpected situations SPECIFIC SAFETY PRECAUTIONS WARNING This generator produces enough electric power to cause a serious shock or electrocution if misused 1 All users must understand the operation of all controls and learn how to quickly stop the generator in case of emergency Understand the use of all generator controls output receptacles and connections 2 Ifthe generator is stored outdoors and is unprotected from the weather check all of the electrical components on the control panel before each use Moisture or ice can cause a malfunction or short circuit in the electrical components which could result in electrocution 3 Do not connect to a building s electrical system unless a qualified electrician has installed an isolation switch 4 All circuit maintenance and installation must be performed by a qualified service professional and should meet all relevant standards 5 The engine and exhaust become very hot during operation Severe thermal burns can occur on contact especially with the muffler a Keep the generator at least 3 feet 1 meter away from buildings
22. doivent tre branch s dans une prise qui est correctement install e et mise la terre conform ment tous les codes et tous les r glements Ne retirez jamais la broche de masse et ne modifiez jamais la fiche N utilisez pas de fiche d adaptation Consultez un lectricien qualifi si vous doutez de la mise la terre appropri e d une prise En cas de d faillance lectronique ou de bris de l outil la mise la terre procure un trajet de faible r sistance pour loigner l lectricit de l utilisateur 5 N utilisez pas le cordon de mani re abusive Ne transportez jamais l outil par le cordon et ne tirez jamais sur celui ci pour enlever la fiche de la prise Gardez le cordon d alimentation l cart des sources de chaleur de l huile des rebords coupants ou des pi ces mobiles N utilisez pas cet outil si le cordon d alimentation est effil ou endommag Remplacez imm diatement les cordons endommag s Les cordons endommag s augmentent le risque de choc lectrique Ne modifiez pas la fiche de quelque facon que ce soit 6 Sivous utilisez un outil lectrique l ext rieur utilisez une rallonge d ext rieur identifi e W A ou W Ces rallonges sont approuv es pour un usage ext rieur et r duisent le risque de choc lectrique Utilisez avec un disjoncteur de fuite la terre GFCI Si l utilisation d un outil lectrique dans un lieu humide est in vitable l usage d un disjoncteur de fuite la terre r duit le
23. dur e de vie utile du moteur Les huiles sans d tergent et pour moteurs 2 temps endommageront le moteur et ne sont pas recommand es 1 V rifiez le niveau d huile AVANT CHAQUE UTILISATION alors que le g n rateur se trouve sur une surface plane et de niveau et que le moteur est arr t 2 Utilisez une huile pour moteur 4 temps qui atteint ou qui d passe les exigences de classification SJ pour le service API REMARQUE Consultez toujours l tiquette de service API sur le contenant d huile pour vous assurer qu elle affiche les lettres SJ 3 L huile SAE 10W 30 est recommand e pour un usage g n ral toutes les temp ratures D autres viscosit s figurant dans la figure 6 peuvent tre utilis es lorsque la temp rature moyenne dans votre r gion est dans la plage indiqu e VERIFICATION DU NIVEAU D HUILE 1 Enlevez le bouchon de remplissage d huile et essuyez la jauge 2 V rifiez le niveau d huile en ins rant la jauge dans le goulot de remplissage sans la visser 3 Sile niveau est bas remplissez avec le type d huile recommand jusqu au haut du goulot de remplissage Bouchon de is Fig 5 remplissa pei h zi Grade de viscosit SAE Temp rature ambiante Visitez www princessauto com pour plus d informations 9 V 3 04 G n rateur essence 6 500 W 8254146 V rifiez la jauge d huile et remplissez le r servoir si le niveau du carburant est bas j Remplissez le r servoir avec soin pour ne pas
24. eck the oil level NOTE Wash your hands with soap and water after handling used oil AIR CLEANER SERVICE A dirty air cleaner will restrict airflow to the carburetor To prevent carburetor malfunction regularly service the air cleaner Service more frequently when operating the generator in extremely dusty areas WARNING Never run the generator without the air filter Rapid engine wear will result 1 Unsnap the air cleaner cover clips remove the air cleaner cover and remove the element 2 Wash the air cleaner element in a solution of household detergent and warm water then rinse thoroughly or wash in nonflammable or high flashpoint solvent Allow the air cleaner element to dry thoroughly 3 Soak the air cleaner element in clean engine oil and squeeze out the excess oil The engine will smoke during initial startup if too much oil is left in the air cleaner element 4 Reinstall the air cleaner element and the cover Element Visit www princessauto com for more information 13 V 3 04 6 500W Gasoline Generator 8254146 FUEL SEDIMENT CUP CLEANING The sediment cup prevents dirt and water that may be in the fuel tank from entering the carburetor If the engine has not been running for a long time the sediment cup should be cleaned 1 Turn the fuel valve lever to the OFF position Remove the sediment cup O ring and filter 2 Clean the sediment cup O ring and filter in nonflammable or high flash point solvent 3 Re
25. el level is low 2 Refuel carefully to avoid spilling fuel Do not fill above the shoulder of the fuel strainer WARNING Gasoline is highly flammable and explosive you could be seriously burned or injured if fuel is ignited during refuelling 3 Stop the engine and keep heat sparks and flame away from the fuelling area 4 Refuel only outdoors 5 This engine is certified to operate on unleaded gasoline use unleaded gasoline with a pump octane of 86 or higher NOTE Unleaded gasoline produces fewer engine and spark plug deposits and extends the life of the exhaust system Never use stale or contaminated gasoline or an oil gasoline mixture Do not allow dirt or water to enter the fuel tank Visit www princessauto com for more information 9 V 3 04 6 500W Gasoline Generator 8254146 STARTING STOPPING THE ENGINE STARTING THE ENGINE 1 Make sure that the AC circuit breaker is in the OFF position The generator may be hard to start if a load is connected Turn the fuel valve lever to the ON position Pull the choke rod to the CLOSED Move the engine switch to the ON position Lightly pull the starter grip until resistance is felt then pull briskly ae D NOTE If you have closed the choke push it to the IN OPEN position as the engine warms up STOPPING THE ENGINE In an emergency Move the engine switch to the O OFF position In normal use 1 Turn the AC circuit breaker to the OFF position
26. essence 6 500 W 8254146 ENTREPOSAGE Avant de remiser l appareil pour une p riode prolong e 1 Assurez vous que la zone d entreposage ne pr sente pas d humidit et de poussi re excessives 2 Proc dez l entretien de la facon d crite dans le tableau suivant Temps d entreposage M thode d entretien recommand e afin de pr venir un d marrage difficile Moins de 1 mois Aucune pr paration n est n cessaire 1 2 mois Remplissez d essence fraiche et ajoutez un conditionneur pour essence 2 mois 1 an Remplissez d essence fraiche et ajoutez un conditionneur pour essence Videz la cuve flotteur du carburateur Videz le bac de s dimentation de carburant 1 an ou plus Remplissez d essence fraiche et ajoutez un conditionneur pour essence Videz la cuve flotteur du carburateur Videz le bac de s dimentation de carburant Enlevez la bougie et versez une cuill re table d huile moteur dans la culasse Tirez doucement sur le lanceur rappel pour distribuer l huile uniform ment dans le cylindre R installez la bougie Changez l huile moteur Apr s l avoir sorti du remisage videz l essence remis e dans un contenant appropri et remplissez d essence fraiche avant de d marrer Probl me Cause possible Solution propos e Le moteur ne d marre pas Y a t il du carburant dans Remplissez le r servoir le r servoir de carburant Y a t il suffisamment d huile dans Ajo
27. ge drain the stored gasoline into a suitable container and fill with fresh gasoline before starting TROUBLE SHOOTING Problem The engine will not start Possible Cause Suggested Solution Is there fuel in the tank Refill the fuel tank Is there enough oil in Add the recommended oil the engine Is the spark plug in Readjust the gap and dry the spark plug Replace good condition it if necessary Is the fuel reaching Clean the fuel sediment cup the carburetor No electricity at the AC receptacles Is the AC circuit breaker ON Turn the AC circuit breaker ON Check the electrical appliance Replace the electrical appliance or equipment or equipment for any defects Take the electrical appliance or equipment to an electrical shop for repair If the engine still does not start take the generator to an authorized service professional for repair Visit www princessauto com for more information 15 8254146 6 500W Gasoline Generator WIRING DIAGRAM V 3 04 Circuit Breaker Main Coil Y DC Coil 1 1 Gr QVR1 5mm mm m 1 Bl QVRI Smm CI 88 8A DC Coil 2 Sm 5mm ca Br QVRO 5mm 5m Br QVRO 5mm lt gt ato ESS 0 QVRO Sum 2 ij It 0 2 0 QVRO 5mm QVRO Smm Bl QYRO Smm E Smm 3 B1 W QVRO 5mm Magnetic Oil Alert U
28. install the filter O ring and sediment cup 4 Turn the fuel valve lever to the ON position and check for leaks SPARK PLUG SERVICE To ensure proper engine operation the spark plug must be properly 0 023 0 031in gapped and free of deposits If the engine has been running the muffler 0 76 0 80 mm will be very hot Be careful not to touch the muffler 1 Remove the spark plug cap 2 Clean any dirt from around the spark plug base 3 Usea spark plug wrench to remove the spark plug 4 Visually inspect the spark plug Discard it if the insulator is cracked chipped or fouled 5 Measure the plug gap with a feeler gauge If necessary correct the gap by carefully bending the side electrode NOTE The gap should be 0 028 to 0 031 in 0 70 to 0 80 mm 6 Check that the spark plug washer is in good condition and thread the spark plug in by hand to prevent cross threading 7 After the spark plug is seated tighten with a spark plug wrench to compress the washer NOTE If installing a new spark plug tighten 1 2 turn after the spark plug seats to compress the washer If reinstalling a used spark plug tighten 1 8 to 1 4 turn after the spark plug seats to compress the washer WARNING The spark plug must be securely tightened An improperly tightened spark plug can become very hot and could damage the engine Never use spark plugs that have an improper heat range SPARK ARRESTER MAINTENANCE If the generator has been running the
29. ipement de s curit appropri ne se trouvent pas proximit de l aire de travail S CURIT PERSONNELLE ATTENTION Portez de l quipement de protection homologu par l Association canadienne de normalisation CSA ou l American National Standards Institute ANSI quand vous utilisez l outil 1 Protection de la t te a Portez toujours des lunettes antiprojections qui offrent une protection frontale et lat rale pour les yeux b Portez des bouchons d oreilles ou des casques protecteurs d oreilles si le moteur ou l environnement de travail est bruyant 2 Gants a Les gants doivent prot ger en fonction des niveaux thermiques chaleur produits par le g n rateur 3 V tements de protection a Portez des v tements de protection concus pour l environnement de travail et pour le moteur 4 Protection des pieds a Portez des chaussures embout d acier ou des coquilles d acier pour viter les blessures caus es par la chute d objets b Les chaussures antid rapantes sont recommand es pour maintenir la stabilit et l quilibre 5 Gardez le contr le du moteur de vos mouvements et de l environnement de travail pour viter les blessures ou le bris du g n rateur a Conservez les v tements bijoux cheveux etc loign s des pi ces mobiles pour viter leur enchev trement avec le moteur Une amputation traumatique ou de graves lac rations peuvent en r sulter b N utilisez pas d outils ou d appareil si vous tes fatigu
30. is tirez soudainement REMARQUE Si vous avez ferm l trangleur enfoncez le vers la position ouvert au fur et mesure que le moteur se r chauffe ARR T DU MOTEUR En cas d urgence Mettez l interrupteur du moteur en position O arr t En mode normal 1 Placez le disjoncteur c a la position OFF arr t D branchez les c bles de chargement c c de la batterie 2 Mettez l interrupteur du moteur en position O arr t 3 Tournez le levier du robinet de carburant en position OFF arr t 10 En cas de questions techniques appelez le 1 800 665 8685 8254146 G n rateur essence 6 500 W V 3 04 INTERRUPTEUR DE PROTECTION DES RENSEIGNEMENTS 1 Lorsque la charge atteint la puissance nominale le t moin lumineux s allume au vert 2 Lorsque la charge atteint la puissance maximale le t moin lumineux s allume au rouge et l avertisseur sonore se fait entendre 3 Lorsque la charge exc de la puissance maximale pendant 1 minute elle interrompt automatiquement la puissance de sortie 4 Appuyez sur l interrupteur pour remettre le g n rateur en marche SYSTEME DE GENERATEUR AUTOMATIQUE AGS Apr s l installation assurez vous que l appareil n est pas surcharg Advenant une coupure de courant le g n rateur interrompra automatiquement le circuit ext rieur le syst me de d marrage et la production de courant Alors que la source d nergie ext rieure devient normale le g n rateur s arr tera et
31. itudes above 5 000 feet 1 500 metres have a qualified service technician perform these carburetor modifications The engine will continue to meet emission standards once the modifications have been performed however engine horsepower will decrease 3 5 for every 1 000 feet 300 metres of altitude Altitude will have an even greater effect on horsepower if the carburetor modifications are not performed Visit www princessauto com for more information 11 V 3 04 6 500W Gasoline Generator 8254146 WARNING When the carburetor has been modified for high altitude operation the air fuel mixture will be too lean for low altitude use Operation at altitudes below 5 000 feet 1 500 metres with a modified carburetor may cause the engine to overheat and result in serious engine damage MAINTENANCE Proper maintenance is essential for safe economical and trouble free operation It will also help to reduce air pollution WARNING Improper maintenance or failure to correct a problem before operation can cause a malfunction in which you can be seriously injured or killed kir rita SAFETY Make sure the engine is off before you begin any maintenance or repairs Let the engine and exhaust system cool before you touch it 3 To reduce the possibility of fire or explosion be careful when working around gasoline Use only a nonflammable solvent not gasoline to clean parts Keep cigarettes sparks and flames away from all fuel related parts MAI
32. les autres pi ces afin d augmenter la vitesse du moteur 2 Entretenez le moteur avec soin voir Entretien 3 Avant d utiliser le moteur retirez en les clavettes et les cl s de r glage Une cl ou clavette laiss e en place sur une pi ce rotative augmente le risque de blessure Visitez www princessauto com pour plus d informations 5 V 3 04 G n rateur essence 6 500 W 8254146 1 Retirez soigneusement les pi ces et les accessoires de l emballage Conservez les mat riaux d emballage jusqu ce que vous ayez inspect avec soin et install ou utilis le g n rateur de mani re satisfaisante 2 Inspectez le moteur attentivement pour vous assurer que le g n rateur n a pas t endommag pendant le transport AVERTISSEMENT Ne faites pas fonctionner le g n rateur si des pi ces sont manquantes Remplacez les pi ces manquantes avant l utilisation Le non respect de cet avertissement peut entra ner une d fectuosit et des blessures graves IDENTIFICATION DES PIECES Capuchon du r servoir de carburant R servoir de carburant Poign e Tige d trangleur Filtre a air Lanceur a rappel Cadre Bouchon de vidange d huile Jauge Roue Panneau de commande Af 7 rG8 mnrmuocoul2 CLE DU MOTEUR D marrage et arr t du moteur Position de la cl marche Fonctionnement du moteur suite au d marrage O arr t Pour arr ter le moteur Il est possible d enlever ins rer la cl LANCEUR RAP
33. lied by the operator NOTE Keep this manual for safety warnings precautions operating inspection and maintenance instructions 2 For technical questions call 1 800 665 8685 8254146 6 500W Gasoline Generator V 3 04 WORK AREA 1 Operate in a safe work environment Keep your work area clean and well lit 2 Do not use in the presence of flammable gases or liquids a Do not use pressurized starting fluids with the generator because the vapors are flammable 3 Keep anyone not wearing appropriate safety equipment away from the work area PERSONAL SAFETY CAUTION Wear protective equipment approved by the Canadian Standards Association CSA or the American National Standards Institute ANSI when using the tool 1 Head Protection a Always wear impact resistant safety goggles that provide both front and side protection b Wear earplugs or hearing protector earmuffs if the engine or work environment is noisy 2 Gloves a Wear gloves that provide protection based on the thermal heat levels generated by the generator 3 Protective Clothing a Wear protective clothing designed for the work environment and the engine 4 Foot Protection a Wear steel toed footwear or steel toecaps to prevent injury from falling objects b Non skid footwear is recommended for maintaining proper footing and balance 5 Control the engine personal movement and the work environment to avoid personal injury or damage to the generator a Keep articles of
34. matically stop the engine the engine switch will remain in the ON position The oil alert system should not take the place of checking the oil level before each use If the engine stops and will not restart check the engine oil level before troubleshooting other areas 6 For technical questions call 1 800 665 8685 8254146 6 500W Gasoline Generator V 3 04 AC CIRCUIT BREAKER The AC circuit breaker will automatically switch OFF if there is a short circuit or a significant overload of the generator at the receptacle If the AC circuit breaker is automatically switched OFF check that the appliance is working properly and does not exceed the rated load capacity of the circuit before once again switching ON the circuit breaker The AC circuit breaker may be used to switch the generator power ON or OFF AC CIRCUIT PROTECTOR Big The AC circuit protector will automatically switch OFF if there is a short circuit or a significant overload of on the generator at the 20A 120V 30A 120V plug If an AC circuit protector automatically switches OFF check that the appliance is working properly and does not exceed the rated load capacity of the circuit before resetting the AC circuit protector to the ON position i i WATTAGE REFERENCE CHART The following table provides reference information for connecting electric appliances to the generator Tool or Appliance Rated R
35. mes hard to read CARBON MONOXIDE POISONING WARNING Engine exhaust contains carbon monoxide gas never start or run this engine indoors Opening windows and doors is not enough to ventilate the area Carbon monoxide is a colourless and odourless gas that is difficult to detect Carbon monoxide poisoning results from inhalation of the gas and may be lethal if left untreated Evacuate all people to an area with clean air and seek immediate medical attention for any person experiencing the following symptoms Headache Confusion Shortness of breath Weakness Fatigue Dizziness Unstable gait stumbling around Nausea amp vomiting Unconsciousness 10 Flu like symptoms O69 0 gr P oN NOTE As a precaution install a carbon monoxide detector in any work area that has gasoline powered equipment ELECTRICAL SAFETY 1 Disconnect power supply Disconnect the tool from the power supply when not in use before cleaning servicing or changing any parts or accessories 2 Protect yourself against electrical shock when working on electric equipment Avoid body contact with grounded surfaces such as pipes radiators cooking stoves and refrigerators There is an increased chance of electrical shock if your body is grounded 3 Double insulated tools are equipped with a polarized plug one blade is wider than the other This plug will fit in a polarized outlet only one way If the plug does not fully fit in the outlet reverse the plug
36. n the fuel valve lever to the OFF position after stopping then engine CHOKE ROD The choke is used to provide an enriched fuel mixture when starting a cold engine It can be opened and closed by manually operating the choke rod Pull out the choke rod to the CLOSED position to enrich the mixture for cold starting GROUND TERMINAL The generator ground terminal is connected to the frame of the generator the metal non current carrying parts of the generator and the ground terminals of each receptacle DC RECEPTACLE The DC receptacle may ONLY be used for charging 12 volt automotive type batteries The battery must be connected to the generator s DC receptacle with the proper polarity battery positive to the generator positive and battery negative to the generator negative Fuel Valve Lever WARNING Do not start the vehicle while the battery charging cable is connected and the generator is running The vehicle or the generator may be damaged DC CIRCUIT PROTECTOR The DC circuit protector automatically shuts off the DC battery charging circuit when the DC charging circuit is overloaded when there is a problem with the battery or when the battery and the generator are improperly connected OIL ALERT SYSTEM The oil alert system is designed to prevent engine damage caused by an insufficient amount of oil in the crankcase Before the oil level in the crankcase can fall below a safe limit the oil alert system will auto
37. nal de l outil ou de l appareil ne d passe pas celui du g n rateur Ne d passez jamais le courant lectrique nominal maximal du g n rateur Les niveaux de puissance entre le courant nominal et le courant maximal peuvent tre utilis s pendant au plus 30 minutes AVERTISSEMENT Une surcharge substantielle aura pour effet d ouvrir le disjoncteur Si on exc de le d lai de fonctionnement la puissance maximale ou advenant une l g re surcharge le g n rateur ne pourra fermer le disjoncteur ou le protecteur du circuit et cela aura pour effet de r duire la dur e de vie en service du g n rateur FONCTIONNEMENT EN MODE C A 1 D marrez le moteur 2 Fermez le disjoncteur c a 3 Branchez l appareil La plupart des appareils munis d un moteur requi rent plus que leur puissance nominale afin de pouvoir d marrer Ne d passez pas la limite de courant sp cifi e pour une prise Si un circuit surcharg provoque la fermeture du disjoncteur c a ou du protecteur de circuit c a r duisez la charge lectrique au niveau du circuit attendez quelques minutes et replacez ensuite le disjoncteur c a ou le protecteur de circuit c a l tat initial FONCTIONNEMENT A HAUTE ALTITUDE haute altitude le m lange standard d air carburant du carburateur sera trop riche Le rendement diminuera alors que la consommation de carburant augmentera Un m lange tr s riche aura galement pour effet d encrasser la bougie et de rendre le d marrage
38. nit Field Coil Fuel L Protector Spark Generator Block Engine Block Vire pug druontou Pai Black Br Brown r diettow Green Iron Se Switch Connection 0 Orange 2 Brown Red 17 Black White R Rea Ww wnite For technical questions call 1 800 665 8685 16 V 3 04 8254146 m G n rateur Manuel d utilisateur Vous devez lire et comprendre toutes les instructions avant d utiliser l appareil Conservez ce manuel afin de pouvoir le consulter plus tard V 3 04 ae G n rateur 8254146 SP CIFICATIONS Prises 1 prise verrouillable par rotation de 120 240 V 1de12V 4 de 120 V Puissance de sortie max 6 500 W Alimentation continue 5 500 W Cylindr e du moteur 389 cm cubes Type de carburant Essence Lanceur rappel Oui D marrage lectrique Non Capacit du r servoir 25 L 6 6 gal Temps de fonctionnement 50 de charge 11 heures Compteur horaire Non Niveau de bruit 74 dB Fermeture automatique en cas de niveau Oui d huile bas Protection de disjoncteur de fuite la terre Non Pile comprise Non T l commande comprise Non Taille des pneus 10 po INTRODUCTION Le g n rateur de 6 500 W procure de l lectricit sur le lieu de travail ou une alimentation d appoint pour votre foyer ou votre chalet Une cage de retournement de conception robuste munie de roues gonflables de 10 po fa
39. ntier Lampe de travail halog ne 1 000 au quartz Vaporisateur sans air 1 3 CV 600 1 200 Scie alternative 960 960 Perceuse lectrique 1 2 CV 1 000 1 000 Scie circulaire 7 1 4 po 1 500 1 500 Scie a onglets 10 po 1 800 1 800 Rabot sur table 6 po 1 800 1 800 Banc de scie scie a bras 2 000 2 000 radial 10 po Compresseur d air 1 1 2 CV 2 500 2 500 Les puissances en W sont des approximations seulement V rifiez la puissance en W v ritable de l outil ou de l appareil 8 En cas de questions techniques appelez le 1 800 665 8685 8254146 G n rateur essence 6 500 W V 3 04 Outil ou appareil Puissance nominale en W Puissance de surcharge additionnelle en cours de marche en W au moment du d marrage Les puissances en W sont des approximations seulement V rifiez la puissance en W v ritable de l outil ou de l appareil Les puissances en W sont des approximations seulement V rifiez la puissance en W v ritable de l outil ou de l appareil V RIFICATION PR OP RATIONNELLE Installation de la trousse de roue et de la poign e 1 Fixez les deux roues et deux poign es au g n rateur au moyen de boulons et d crous 2 Avant de d marrer le g n rateur enfoncez le syst me de verrouillage des roues et des poign es pour les emp cher de se d placer en cours de fonctionnement HUILE MOTEUR AVERTISSEMENT L huile moteur est un facteur important affectant la performance et la
40. proc dera automatiquement au branchement du circuit Indicateur de niveau AVERTISSEMENT Si le g n rateur refuse de d marrer EG SH Ze de carburant v rifiez si le t moin s allume au moment de d marrer Nu Kc l appareil Ajoutez de l huile si le t moin s allume Num ro du moteur 1 Assurez vous que la charge n est pas excessive et installez ensuite le g n rateur 2 Linterrupteur AGS sur le tableau de commande se trouvera habituellement en position automatique alors que la cl se trouvera en position de marche 3 Placez l interrupteur d trangleur la position Is ouvert SYSTEME D ALARME Le t moin lumineux sera allum au moment de d marrer le g n rateur et si le niveau d huile est trop bas Le t moin lumineux s teindra si le niveau d huile est suffisamment lev UTILISATION E RACCORDEMENT AU SYSTEME ELECTRIQUE D UN EDIFICE Un lectricien qualifi doit proc der au raccordement d alimentation de r serve au niveau du syst me lectrique d un difice Ce raccordement doit permettre d isoler le courant du g n rateur du service public d alimentation en lectricit et il doit tre conforme toutes les lois et tous les codes lectriques en vigueur Un interrupteur de transfert est n cessaire afin d isoler le courant du g n rateur du service public d alimentation en lectricit AVERTISSEMENT Des raccordements inad quats au syst me lectrique d un difice peuvent permett
41. rait pas vous emp cher de v rifier le niveau d huile avant chaque utilisation Si le moteur s arr te et refuse de d marrer v rifiez le niveau d huile moteur avant de proc der au d pannage des autres syst mes DISJONCTEUR C A Le disjoncteur c a s arr tera automatiquement advenant un court circuit ou une surcharge consid rable du g n rateur au niveau de la prise Si le disjoncteur c a s arr te automatiquement v rifiez si l appareil fonctionne correctement et s il n exc de pas la capacit de charge nominale prescrite du circuit avant de replacer le disjoncteur c a la position ON marche Le disjoncteur c a peut tre utilis pour ouvrir ou fermer la source d alimentation au niveau du g n rateur PROTECTEUR DE CIRCUIT C A Fig2 Le disjoncteur c a s arr tera automatiquement advenant un court circuit ou une surcharge if consid rable du g n rateur au niveau de la fiche de 20 A 120 V 30 A 120 V Si un protecteur de circuit c a s arr te automatiquement v rifiez si l appareil fonctionne correctement et s il n exc de pas la capacit de charge nominale prescrite du circuit avant de replacer le protecteur de circuit c a la ER position ON marche arr t TABLEAU DE REFERENCE DE LA PUISSANCE EN W Un quipement lectrique dont tout particuli rement le moteur produit un courant lev au moment du d marrage Le tableau suivant constitue une r f rence au moment de brancher ces installations au g n ra
42. re au courant lectrique du g n rateur de revenir vers les lignes lectriques Un tel retour du courant peut avoir pour effet d lectrocuter les travailleurs de la soci t publique d lectricit ou quiconque toucherait aux lignes pendant une panne de courant sans compter que le g n rateur pourrait exploser br ler ou causer un incendie au moment o le courant sera r tabli Consultez la soci t publique d lectricit ou un lectricien qualifi SYSTEME DE MISE A LA MASSE Le g n rateur portatif est muni d un dispositif de mise la masse qui relie les composants de son cadre aux bornes de mise la masse qui se trouvent l int rieur des prises de sortie c a La mise la masse du syst me n est pas reli e au fil neutre de c a Visitez www princessauto com pour plus d informations 11 V 3 04 G n rateur essence 6 500 W 8254146 APPLICATIONS C A Avant de brancher un appareil ou un cordon d alimentation au g n rateur 1 Assurez vous qu il est en bon tat de marche Les appareils ou les cordons d alimentation d fectueux peuvent entra ner un risque de choc lectrique 2 Si un appareil se met fonctionner de fa on anormale ou lente ou s il s arr te brusquement placez le hors tension imm diatement D branchez l appareil et d terminez si le probl me se situe au niveau de l appareil ou si on a d pass la capacit de charge nominale du g n rateur 3 Assurez vous que le courant lectrique nomi
43. s indiqu ou utilisation 20 premi res 50 heures 100 heures heures apr s l intervalle donn d heures de heures fonctionnement selon l v nement qui survient en premier Huile moteur V rification X Vidange X X Filtre air V rification X Nettoyage A Bac de Nettoyage X s dimentation Bougie Nettoyage r glage X Remplacement X Pare tincelles Nettoyage X Vitesse au V rification r glage X ralenti Jeu de la V rification r glage X soupape Chambre de Nettoyage Apr s toutes les 500 heures combustion R servoir de Nettoyage X carburant et filtre Tube V rification Tous les 2 ans remplacez au besoin carburant En cas d utilisation commerciale notez le nombre d heures de fonctionnement pour d terminer les intervalles d entretien appropri s Entretenez plus souvent si utilis dans des zones poussi reuses Visitez www princessauto com pour plus d informations 13 V 3 04 G n rateur essence 6 500 W 8254146 VIDANGE D HUILE MOTEUR Vidangez l huile alors que le moteur est chaud pour assurer une vidange rapide et compl te 1 D vissez le bouchon de vidange et la rondelle d tanch it enlevez le bouchon de remplissage d huile et vidangez l huile 2 R installez le bouchon de vidange d huile et la rondelle d tanch it Serrez solidement le bouchon 3 Remplissez de l huile recommand e et v rifiez le niveau d huile REMARQUE Lavez vous les mains avec de l eau savonneuse apr s avoir manipul de l
44. s ressemblant la grippe D 99 IO OT qe co moi REMARQUE Installez un d tecteur de monoxyde de carbone dans l aire de travail o se trouve un quipement aliment en essence en guise de pr caution 4 En cas de questions techniques appelez le 1 800 665 8685 8254146 G n rateur essence 6 500 W V 3 04 S CURIT EN LECTRICIT D branchez la source d nergie D branchez l outil de la source d nergie lorsqu il n est pas utilis et avant le nettoyage l entretien ou le remplacement de pi ces ou d accessoires 2 Prot gez vous contre les chocs lectriques lorsque vous travaillez en pr sence d quipement lectrique vitez le contact entre votre corps et les surfaces reli es la terre comme les tuyaux radiateurs cuisini res et r frig rateurs Il y a un risque plus lev de choc lectrique si votre corps est mis la terre 3 Les outils double isolation sont munis d une fiche polaris e une broche est plus large que l autre Cette fiche s ins rera dans une prise polaris e dans une direction seulement Si la fiche ne s ins re pas compl tement dans la prise tournez la Si elle ne s ins re toujours pas contactez un lectricien qualifi pour faire installer une prise polaris e Ne modifiez pas la fiche de quelque facon que ce soit L isolant double limine le besoin d un cordon d alimentation trois fils mis la terre et d une source d nergie mise la terre 4 Les outils mis la terre
45. sauto com pour plus d informations 3 V 3 04 G n rateur essence 6 500 W 8254146 5 Le moteur et le syst me d chappement deviennent tr s chauds pendant le fonctionnement Des br lures thermiques graves peuvent se produire lors d un contact tout particuli rement avec le silencieux a Conservez le g n rateur au moins 1 m 3 pi de toutes les structures et autres quipements pendant le fonctionnement b Retirez les d bris accumul s du silencieux et dans la zone du cylindre Les d bris combustibles comme les feuilles l herbe les buissons etc peuvent prendre feu s ils viennent en contact avec un moteur chaud C vitez de placer quoi que ce soit sur le g n rateur lorsqu il est en marche d Laissez le silencieux le cylindre du moteur et les ailettes refroidir avant de toucher un terrain non am nag recouvert d herbe ou de buissons e Lessence est extr mement inflammable et explose dans certaines conditions Ne fumez pas ni n utilisez de flammes ou d tincelles l endroit o l on fait le plein du g n rateur et o l essence se trouve entrepos e Remplissez le moteur de carburant dans une zone bien a r e et avec le moteur coup f Les manations de carburant s enflamment extr mement facilement et peuvent s allumer apr s que le moteur ait d marr Assurez vous d essuyer tout d versement de carburant avant de d marrer le g n rateur 6 Ne permettez pas aux enfants d utiliser le g n rateur et ne lai
46. sk of electrical shock It is recommended that the GFCI should have a rated residual current of 30 mA or less 7 Avoid using an unnecessarily long extension cord Choose a cord that is appropriate for the situation A cord that is too long and running across the floor can be more dangerous than helpful Using a cord that is too long or too thin could damage the tool Unroll the cord completely to prevent it from overheating 8 Place the electrical cord in a position that prevents it from coming into contact with the tool and from getting caught by the work piece The cord should always stay behind the tool BATTERY PRECAUTIONS 1 Keep the battery away from fire and sparks Reinforce the grounding and down lead 2 The battery contains strong acid Avoid contact with skin and eyes If contact occurs immediately wash skin or flush eyes with water If serious injury occurs seek medical attention 3 To prevent damage avoid spilling gasoline oil or organic material on the battery This generator was designed for a specific function Do not modify or alter this generator or use it for an unintended purpose a Do not tamper with the governor spring the links or any other parts in an attempt to increase the engine s speed 2 Maintain the engine with care see Maintenance 3 Remove adjusting keys and wrenches from the engine before operation A wrench or key that is left attached to a rotating part of the tool increases the risk of personal injury
47. ssez personne qui ne connait pas le g n rateur utiliser celui ci sans une surveillance ad quate 7 N enlevez jamais les tiquettes d avertissement Les g n rateurs sont con us pour servir de fa on s re et fiable s ils sont utilis s selon les instructions Veuillez lire et comprendre le manuel du propri taire avant d utiliser votre g n rateur Vous pouvez contribuer pr venir les accidents si vous connaissez bien l appareil REMARQUE Les tiquettes de s curit vous avisent des risques de dangers pouvant entrainer des blessures graves Lisez les avec soin Communiquez avec Princess Auto si une tiquette s est arrach e ou est devenue illisible EMPOISONNEMENT AU MONOXYDE DE CARBONE AVERTISSEMENT Ne d marrez et ne laissez jamais fonctionner ce moteur l int rieur puisque les gaz d chappement contiennent du monoxyde de carbone L ouverture des fen tres et des portes ne suffit pas pour a rer l endroit Le monoxyde de carbone est un gaz incolore et inodore qui est difficile d tecter L empoisonnement au monoxyde de carbone r sulte de l inhalation du gaz et peut tre mortel en l absence de traitement Evacuez tous les gens vers un endroit o l air est pur et consultez imm diatement un m decin si un individu ressent les sympt mes suivants Maux de t te Confusion Essoufflement Faiblesse Fatigue Etourdissements D marche instable tituber Naus e et vomissement Perte de conscience 10 Sympt me
48. teur Outil ou appareil Puissance nominale en W Puissance de surcharge additionnelle en cours de marche en W au moment du d marrage Caract ristiques essentielles Ampoule 75 W 79 Les puissances en W sont des approximations seulement V rifiez la puissance en W v ritable de l outil ou de l appareil Visitez www princessauto com pour plus d informations 1 V 3 04 G n rateur a essence 6 500 W 8254146 Outil ou appareil Puissance nominale en W Puissance de surcharge additionnelle en cours de marche en W au moment du d marrage Surg lateur 500 500 Pompe de puisard 800 1 200 R frig rateur cong lateur 18 pi 800 1 600 cubes Pompe de puits d eau 1 3 CV 1 000 2 000 Chauffage climatisation Climatiseur de fen tre 10 000 BTU 1 200 1 800 Ventilateur de fen tre 300 600 Ventilateur de fournaise de 1 2 CV 800 1 300 Cuisine Four micro ondes 1 000 W 1 000 Cafeti re 1 500 Four lectrique Un seul l ment 1 500 Plaque chauffante 2 500 gt Salle familiale Lecteur de DVD CD 100 Magn toscope 100 R cepteur st r o 450 T l vision en couleur 27 po 500 Ordinateur personnel avec cran de 800 17 po Autre Syst me de s curit 180 Radio r veil AM FM 300 Ouvre porte de garage 1 2 CV 480 520 Chauffe eau lectrique 40 gal 4 000 Bricolage cha
49. u cadre du g n rateur aux pi ces non conductrices du g n rateur ainsi qu aux bornes de mise a la masse de chaque prise RECEPTACLE C C La prise c c peut tre utilis e SEULEMENT pour charger les batteries de 12 V pour automobiles La batterie doit tre reli e la prise c c du g n rateur en respectant la polarit soit la borne positive de la batterie reli e au c t positif du g n rateur et la borne n gative de la batterie reli e au c t n gatif du g n rateur AVERTISSEMENT Ne d marrez pas le v hicule alors que le c ble de charge de la batterie est branch et si le g n rateur est en marche Le v hicule ou le g n rateur pourrait subir des dommages PROTECTEUR DE CIRCUIT C C Le protecteur de circuit c c interrompt automatiquement le circuit de charge c c de la batterie s il est surcharg lorsque la batterie pr sente un probl me ou lorsque la batterie et le g n rateur ne sont pas reli s correctement SYSTEME D ALERTE DE NIVEAU D HUILE Le syst me d alerte de niveau d huile a t concu afin de pr venir les dommages au niveau du moteur si le niveau d huile l int rieur du carter moteur est trop bas Avant que le niveau d huile l int rieur du carter moteur ne descende en dessous d un niveau s curitaire le syst me d alerte de niveau d huile arr tera automatiquement le moteur l interrupteur du moteur demeurera la position marche Le syst me d alerte de niveau d huile ne dev
50. ugie est en bon tat et vissez ensuite la bougie la main afin d emp cher tout croisement des filets 7 Apr s que la bougie a t install e serrez avec une cl bougie afin de comprimer la rondelle REMARQUE Si vous installez une bougie neuve serrez de 1 2 tour apr s le contact de la bougie afin de comprimer la rondelle Si vous r installez une bougie usag e serrez de 1 8 1 4 tour apr s le contact de la bougie afin de comprimer la rondelle AVERTISSEMENT La bougie doit tre serr e solidement Une bougie pr sentant un serrage inad quat peut devenir tr s chaude et risquer ainsi d endommager le moteur N utilisez jamais de bougies pr sentant un degr thermique inad quat ENTRETIEN DU PARE ETINCELLES Le silencieux sera tr s chaud si le g n rateur tait en marche Laissez le refroidir avant de continuer AVERTISSEMENT Le pare tincelles doit faire l objet d un entretien toutes les 100 heures afin de pr server son efficacit Nettoyez le pare tincelles en proc dant comme suit 1 Desserrez la vis situ e pr s de l orifice d chappement du silencieux et enlevez le pare tincelles 2 Au moyen d une brosse enlevez les d p ts de carbone du tamis du pare tincelles V rifiez si le tamis est bris ou d chir et remplacez le au besoin 3 Installez le pare tincelles en proc dant dans l ordre inverse de la d pose Visitez www princessauto com pour plus d informations 15 V 3 04 G n rateur
51. unning Watts Additional Surge Starting Watts Essentials Light Bulb 75 watt 75 Deep Freezer 500 500 Sump Pump 800 1200 Refrigerator Freezer 18 Cu Ft 800 1600 Water Well Pump 1 3 HP 1000 2000 Heating Cooling Window Air Conditioner 10 000 BTU 1200 1800 Window Fan 300 600 Furnace Fan Blower 1 2 HP 800 1300 Kitchen Microwave Oven 1 000 watt 1000 E Coffee Maker 1500 gt Electric Stove Single Element 1500 Hot Plate 2500 Family Room DVD CD Player 100 VCR 100 Stereo Receiver 450 Colour Television 27 in 500 Personal Computer with 17 in Monitor 800 Other Security System 180 AM FM Clock Radio 300 Garage Door Opener 1 2 HP 480 520 Electric Water Heater 40 Gallon 4000 Wattages listed are approximate only Check tool or appliance for actual wattage Visit www princessauto com for more information 1 V 3 04 6 500W Gasoline Generator 8254146 Tool or Appliance Rated Running Watts Additional Surge Starting Watts DIY Job Site Quartz Halogen Work Light 1000 Airless Sprayer 1 3 HP 600 1200 Reciprocating Saw 960 960 Electric Drill 1 2 HP 1000 1000 Circular Saw 7 1 4 in 1500 1500 Miter Saw 10 in 1800 1800 Table Planer 6 in 1800 1800 Table Saw Radial Arm Saw 10 in 2000 2000 Air Compressor 1 1 2 HP 2500 2500 Wattages listed are approximate only Check tool or appliance for actu
52. utez l huile recommand e le moteur La bougie est elle en bon tat Rajustez l clateur et s chez la bougie Remplacez la au besoin Le carburant parvient il Nettoyez le bac de s dimentation au carburateur de carburant Aucune lectricit au niveau des Le disjoncteur c a est il ouvert Ouvrez le disjoncteur c a prises c a V rifiez si l appareil ou l quipement Remplacez l appareil ou lectrique pr sente des d fauts l quipement lectrique Confiez l appareil ou l quipement lectrique un atelier de r paration Si le moteur refuse toujours de d marrer confiez le g n rateur un professionnel d entretien autoris qui le r parera 16 En cas de questions techniques appelez le 1 800 665 8685 V 3 04 6500 W n rateur essence z G 8254146 r SCHEMA DE CABLAGE Main Coil DC Coil 1 Circuit Breaker Gr QVRI 5mm w Bl QVR1 5mm 88 8A DC Coil 2 Br QVRO 5mm QVRO 5mm QVRO 5mm e 0 QVRO 5mm QVRO 5mm QVRO 5mm N 5mm QVRO Magnetic Field Coil Generator Block Engine Block in 0 0 QVRO Smm QVRO Smm i Ld Fuel Solenoid Valve 2 B1 V Bl I QVRO 5mm QVRO 5mm B1 W QVRO 5mm Oil Alert Unit Fuel Protector Spark Plug Ignition Coil mmia ar Brown f