1. TERRENT AAARAAARARARG Figure 2 Figure 3 B Instructions All of the following tests can be performed by using the red and black test leads or the modular plug NOTE When using the modular test plug the polarity test function applies to Lines 1 and 2 The continuity and tone functions ONLY apply to Line 1 e POLARITY TEST IDENTIFYING TIP amp RING SWITCH TO OFF a Connect the RED test lead to the side of one line and the BLACK lead to the side of another line b The LED will glow GREEN when you connect the RED test lead to the RING SIDE of the line c The LED will glow RED when you connect the RED test lead to the TIP SIDE of the line e IDENTIFYING LINE CONDITION SWITCH TO OFF a Connect the RED test lead to the RING SIDE of the line and the BLACK to the TIP 4 b Watch the LED ABRIGHT GREEN LED indicates a CLEAR line Il A DIM GREEN LED indicates a BUSY line Ill A BRIGHTLY FLICKERING GREEN RED LED indicates a RINGING line e VERIFYING LINES SWITCH TO OFF THEN CONT a Dial the line to be verified b While the line is ringing connect the RED lead to the RING SIDE of the line and the BLACK to the TIP c In the OFF position the indicator lamp will flicker RED and GREEN when the test leads are connected to the subject pair d If you switch the test set to CONT it will terminate the
2. consequential damages 8
3. fil rouge et le fil noir aux 2 c bles e Appuyez sur 5 plus d 1 seconde pour mettre en marche la sonde active La sonde met un bip lorsqu elle se met en marche La LED rouge s allume ponctuellement toutes les 4 secondes pour rappeler que la sonde fonctionne et que le mode filtre est d sactiv e Une pression rapide sur active le mode filtre La LED verte clignote une fois toutes les 4 secondes pour rappeler que la sonde fonctionne et que le mode filtre est activ La fonction filtre permet de r duire les interf rences et les bruits parasites avec le secteur 50Hz 60Hz e est possible de passer de Filtre on a Filtre off par pressions successives sur le bouton b e Le volume peut tre ajust en fonction de l environnement sonore et permet de r duire le niveau des interf rences e Touchez le c ble tester avec la pointe de la sonde e Le signal sera de plus en plus fort lorsque vous approcherez du c ble reli au g n rateur 2 tons et l intensit lumineuse de la LED sera aussi de plus en plus lev e e Appuyez sur 5 pendant plus 3 secondes pour arr ter la sonde Un bip long est mis La sonde s arr te automatiquement apr s 5 minutes 5 C Utilisation d un casque et de l clairage e Le fait de brancher un casque sur la prise casque met en fonctionnement la sonde sans avoir appuyer sur 5 e La LED en bout de sonde permet d clairer la zone de mesure lorsque les conditi
4. SEFRAM 97 Localisateur de c bles hors tension et testeur de paires t l phoniques Manuel d utilisation Sommaire Page 1 Introduction 1 2 Sonde avec filtre 1 3 3 G n rateur 2 tors dee tri tende 3 6 4 Sp cifications 7 8 5 Maintenance 1 INTRODUCTION Le SEFRAM 97 a t con u selon les normes de s curit Europ ennes CE EN 61326 1 EN 55011 EN 61000 4 2 EN 61000 4 3 Le SEFRAM 97 est congu pour identifier et localiser des c bles hors tension sans endommager les isolants de ces c bles La sonde permet une recherche facile et pr cise du c ble dans un faisceau ou un tableau Les c bles concern s sont les c bles secteur hors tension et les c bles t l phoniques non reli s au r seau t l phonique 2 Sonde active avec filtrage A Caract ristiques e Fonctionne avec tous les g n rateurs 2 tons de la gamme SEFRAM e Volume et sensibilit ajustables e 2 modes avec filtre sans filtre pour r duire les ef fets du secteur 50Hz e Arr t automatique 5mn e Alimentation par pile 9V autonomie 50 heures e Sortie pour casque externe 320 e Eclairage de la zone de mesure par LED B Mise en ceuvre e Branchement au g n rateur 2 tons C ble non branch un quipement Branchez le fil rouge du g n rateur sur le fil rep rer et l autre fil noir la masse de l quipement ou la terre voir figure 1 1 C bles non branch s un quipement Branchez le
5. call on the subject line e SENDING TONE SWITCH TO TONE CAUTION DO NOT CONNECT TO ANY ACTIVE AC CIRCUIT EXCEEDING 24V IN THIS MODE a Connect the test leads to the pair or attach one lead to ground and one lead to either side of the line See figure 1 b A fast dual alternating tone or a slow dual alternating tone can be selected from the switch inside the tone generator See figure 3 c Probe the suspected wires with the filter probe Reception of tone will be strongest on the subject wire In case of ready access to bare conductors a handset may be used to receive the tone 5 e TESTING CONTINUITY SWITCH TO CONT CAUTION DO NOT CONNECT TO ANY ACTIVE AC OR DC CIRCUIT IN THIS MODE a Connect the test leads to the subject pair b Use cont position c A bright GREEN light indicates continuity The LED will not glow if the line resistance exceeds 12k e TESTING CONTINUITY USING TONE SWITCH TO TONE CAUTION DO NOT CONNECT TO ANY ACTIVE AC OR DC CIRCUIT IN THIS MODE a Connect the test leads to the subject pair b Use a handset at the remote end and touch the wire end s with the clip lead s c Reception of tone is an indication of continuity e MODULAR TESTING All above tests are available through the modular plug for line 1 only red and green wires e COAX TESTING a To test unterminated coax connect red to outer shield and black to center conductor or red to outer shield and black to g
6. chez le fil rouge sur le fil de sonnerie et le noir sur le fil de retour 2 b Indication de la LED Si la LED est fortement clair e en VERT LED la ligne est libre Une LED verte faiblement clair e indique une ligne occup e Ill Un LED qui passe de VERT ROUGE indique une sonnerie appel entrant e V rification de la ligne Mettre l interrupteur sur OFF puis sur CONT a Appeler le num ro de la ligne v rifier b Quand ca sonne branchez le fil rouge sur le fil de sonnerie le fil noir sur l autre fil c En position OFF la LED passe de Rouge Vert d Lorsque vous basculer l interrupteur sur CONT cela met fin l appel e Envoi d un signal 2 tons sur la ligne Interrupteur sur TONE Attention ne jamais appliquer une tension 24V dans ce mode a Branchez le fil rouge sur un des fils de la ligne tester et le fil noir sur l autre fil ou la terre voir figure 1 b Vous pouvez choisir un signal 2 tons rapide ou lent par commutation interne du g n rateur voir figure 3 c Suivre avec la sonde le fil diagnostiquer recherche de coupure localisation Plus la sonde est proche du fil plus le signal est fort Il est possible d utiliser un casque suivant les conditions environnementales 5 e Test de continuit Interrupteur sur CONT Attention Ne jamais brancher les c bles du g n rateur sur un circuit sous tension dans ce mode a Branchez les c ble
7. dentify and trace wires or cables within a group without damaging the insulation 2 FILTER PROBE A Features e Works with any Tone Generator to identify wires e Volume control for increasing sensitivity and adjustable to suit work environment e 2 operation modes Filter on Filter off e The auto off function 5 minutes prevents battery consumption e Power supply is available in any 9V battery with a life of approximately 50 hours e A phone jack is designed only for 320 headset handset e Flashlight function B Instructions e Connecting the tone generator In terminated working cables Connect one test lead to a terminated wire and the other test lead to earth or equipment ground See figure 1 In unterminated or non working cables Connect one test lead to an unterminated wire and the other test lead to another unterminated wire Press the round button for more than 1 second to turn on the filter probe You can hear a short beep when you turn on the unit The red LED flashes every 4 seconds as a visual indicator and reminder This is the mode of Filter off e An instant press of the round button to change into the mode of Filter on The green LED flashes every 4 seconds as a visual indicator and reminder This is the mode of Filter on which can avoid the AC power line interference of 50Hz 60Hz e The Filter on mode and the Filter off mode can be exchanged by an instant press
8. e The volume control can be adjusted to suit the environment The volume can be increased to overcome noise or decreased to reduce interference e Touch the tip of the filter probe to the insulation of each suspect conductor e Reception of tone will be loudest on the subject wire The brighter the LED the stronger of tone signal detected e Press the round 5 button for more than 3 seconds to turn off the filter probe You can hear a long beep when you turn off the unit The filter probe also has the auto off function 5 minutes C Special Application e Plug in the phone jack activates the filter probe automatically without a long press of the round cb button It is equipped for connecting a lineman s operation 5 e The flashlight function for easier cable tracing in the dark TONE GENERATOR f A ER BB IE E dl A Features e Red and black test leads with a standard 4 conductor modular cord and plug e A 3 position toggle switch controls the modes of operation and two bi colored LEDs display line polarity for Lines 1 and 2 Figure 2 e The tone and continuity cont test functions are only applied to Line 1 using the modular plug e A tone selector switch located inside the test set is provided for choosing either a fast dual alternating tone or a slow dual alternating tone CAUTION DO NOT CONNECT TO AN ACTIVE AC CIRCUIT EXCEEDING 24V IN THIS MODE 3
9. e incluse Environ 130g Alimentation Connexion Alimentation Sp cifications g n rales Temperature de 0 C 40 C HR 80 Max fonctionnement 10 C 50 C HR 80 Max EN 61326 1 EN 55011 EN 61000 4 2 EN 61000 4 3 Manuel piles housse de transport 5 Maintenance A Nettoyage Nettoyez p riodiquement avec un chiffon doux et humide Ne jamais utiliser de solvant B Remplacement des piles e Sonde active D visser la vis du couvercle pile remplacer la pile en respectant la polarit remettre le couvercle et la vis e G n rateur 2 tons D visser la vis du couvercle remplacer la pile en respectant la polarit remettre le couvercle et visser sans forcer en cas de for age le boitier pourrait tre endommag SEFRAM 32 rue E MARTEL BP 55 F42009 SAINT ETIENNE Cedex 2 Tel 0825 56 50 50 0 15 mn Fax 04 77 57 23 23 Web www sefram fr E mail sales sefram fr SEFRAM 97 CABLE TRACER Filter Probe amp Tone Generator INSTRUCTION MANUAL INDEX PAGE 1 INTRODUC TION rnt rnnt i 1 2 FILTER PROBE cita ada 1 3 3 GENERATOR tette 3 6 4 SPECIFICATION osistaan eens 7 8 De MAINTENANCE rt eret nbn 8 1 INTRODUCTION The SEFRAM 97 has been designed and tested according to CE safety requirements for electronic measuring apparatus EN 61326 1 EN 55011 EN 61000 4 2 EN 61000 4 3 and other safety standard The SEFRAM 97 is designed to i
10. ons d clairage sont mauvaises 3 G n rateur 2 tons Figure1 A Caract ristiques e Sortie du signal sur 2 fils avec pinces crocodiles ou prise t l phone e 1 interrupteur 3 positions permet de choisir la fonction 2 LED bicolores indiquent la polarit voir figure 2 e Le g n rateur 2 tons n envoie le signal 2 tons que sur la Ligne 1 e Un interrupteur interne permet de choisir entre un signal 2 tons lent ou rapide ATTENTION ne jamais appliquer plus de 24V AC la sortie du g n rateur 2 tons 3 10 00 Slow Ti o POLARITY Lo Fast Tone Generator SEFRAM 97 G Bum Figure 2 Figure 3 B Instructions Les tests qui suivent peuvent tre r alis s avec les cordons ou la prise RJ 11 NOTE en utilisant la prise RJ 11g le test de polarit s applique aux lignes 1 et 2 La continuit et le g n rateur 2 tons uniquement la ligne 1 e Test de polarit Recherche du fil de sonnerie Position du commutateur sur OFF a Branchez le fil rouge sur un des fils de la ligne le fil noir sur l autre fil de la seconde ligne b La LED passe au VERT quand le fil rouge est connect au fil de sonnerie de la ligne c la LED passe au Rouge lorsque le fil rouge est branch sur le fil de potentiel bas e Identification de l tat de la ligne Position du commutateur sur OFF a Bran
11. round b To test terminated coax connect red to connector housing and black to center pin or red to connector housing and black to ground 4 SPECIFICATION Filter Probe SEFRAM 97 A Filter on avoid the interference of 50Hz 60Hz Receiver distance lt 50 Sensitivity y Fixed Power source 9V battery x 1 Dimensions 250 L x 39 W 38 D mm Weight battery included Tone Generator SEFRAM 97 G Wave form Square Wave Frequency 1kHz 1596 Over voltage protection 80V DC Alternating tone Fast and Slow RJ11 connector alligator clip x 2 RJ45 connector optional Power source 9Vbatteryx1 Dimensions 86 L x 63 W x 26 D mm Weight battery included Connection General Operating Temperature 0 C 40 C 80 Max amp Humidity Storage Temperature 10 C 50 C 80 Max amp Humidity EN 61326 1 EN 55011 Safety Standard EN 61000 4 2 EN 61000 4 3 5 MAINTENANCE A Cleaning Periodically wipe with a damp cloth and mild detergent do not use abrasives or solvents B Battery Replacement e The filter probe is maintenance free except for battery replacement Remove the screw from the battery compartment replace the 9V battery and reassemble e Separate the case of the tone generator install a fresh 9V battery and reassemble DO NOT OVER TIGHTEN C Warranty limited solely to repair or replacement no warranty of merchantability fitness for a particular purpose or
12. s sur la paire tester b Se mettre sur CONT c Si la LED VERTE s allume il y a continuit Elle ne s allume pas si la r sistance d passe 12k e Test de continuit avec g n rateur 2 tons Interrupteur sur TONE Attention Ne jamais brancher les c bles du g n rateur sur un circuit sous tension dans ce mode a Branchez les c bles sur la paire tester b Mettre un combin l autre bout de la ligne La r ception des 2 tons sur le combin indique la continuit e Utilisation du connecteur RJ 11 Tous les tests ci dessus peuvent se faire avec la prise RJ 11 ligne 1 uniquement fils rouge et verts e Test des coaxiaux a Pour tester un c ble sans connecteur branchez le fil rouge la tresse externe et le fil noir l me ou la terre b Pour tester un c ble coaxial avec connecteur branchez le fil rouge au connecteur et le fil noir l me ou la terre 4 Sp cifications Sonde SEFRAM 97 A Avec filtre r duit les interf rences secteur 50Hz Modes de fonctionnement Pointe de mesure Fixe 1 pile 9V 6F22 alcaline recom mand e Dimensions 250 L x 39 1 x 38 E mm Masse pile incluse Environ 180g G n rateur 2 tons SEFRAM 97 G Forme d onde Signal carr Fr quence ikHzx 15 Protection 80 Type de signal 2 tons rapide ou lent Connecteur RJ11 2 ponces crocodiles 1 pile 9V 6F22 alcaline recom mand e Dimensions 86 L x 63 1 x 26 E mm Masse pil
Download Pdf Manuals
Related Search
Related Contents
DocuColor 8000AP Manuale dell`operatore Weatherables GKPR-OTS-6X44.5 Instructions / Assembly SuperHTM RISC engine Simulator/Debugger V.9.07.01 Genius FaceCam 1005 Benutzerhandbuch Tripp Lite B130-101 video splitter 日本語版 - GSユアサ User`s Manual Samsung AV-R620R Instrukcja obsługi Copyright © All rights reserved.