Home

Please initial use MAXSPECTTM LED Aquarium Lamp

image

Contents

1.
2. 5 minutes F Set of time after full power to save data 2 Program settings A Press TIMER button for more than 2 seconds to enter automatically open and close the setting mode B The first is a WHITE status indicator light indicating that the white group at this time to set the boot or shut down time The default state is displayed on the words that now set the boot time C Click the TIMER button the clock started flashing numbers that are in the clock setting mode press WHITE or BLUE button to set and then click the TIMER key to www aquaportail com switch to the minute setting mode also based on WHITE or BLUE button set D Is set up according to TIMER key to display OFF the words that followed set the shutdown time and then click the TIMER key to begin flashing digital clock that is in the clock setting mode press WHITE or BLUE button to set and then click the TIMER key to switch to the minute setting mode also based on a WHITE or BLUE button to set E Is set up according to TIMER button or more than 5 seconds without any key operation is to save the setting data out of setting mode F In setting mode or set to complete a set of startup and shutdown data press MODE button you can switch to another group of lights automatically open and close time settings G Set a good boot time or shutdown time after full power to save th
3. e data 3 The manual control white light blue light switch A WHITE button you can manually control the white group opening and closing that is click on WHITE button will open the white group and then click WHITE button will close the white group B BLUE Button you can manually control the opening and closing Blu ray group that is click on BLUE button will open the Blu ray group and then click BLUE button then close the Blu ray group 4 Light temperature detection and protection features A Lamps installed on the radiator temperature measurement probe the lamp controller real time temperature will be displayed on the screen B When abnormal conditions such as the cooling fan fails or the cooling holes are blocked heat sink temperature of 600C the controller will issue a warning tone to 700C the internal procedures will automatically cut off the power LED driver and maintained fault tips C When the controller to issue over temperature alarm should immediately stop lamps work to prevent the LED lamp beads generated due to high temperature damage And check the lamp www aquaportail com cooling fan is working properly has blocked the phenomenon of cooling holes 5 Product If you have any unusual conditions or questions please contact dealer as soon as possible Warranty MAXSPECT LED Aquarium Lighting product warranty peri
4. od from the date of purchase for 18 months Warranty does not belong to the following items free of charge range Consumer handling installation use maintenance custody improper damaged Consumer self apart light body and controller resulting in damage to internal parts Consumers provide their own replacement parts to this causing all the damage and loss As the product environmental conditions such as power temperature humidity and other non company factors beyond the control of all the damage and losses are not free of charge within the warranty After a free warranty period No product warranty certificate Due to force majeure resulting in product damage Range of products beyond the product warranty repair the company will be charged the appropriate fees and related costs of spare parts Attention Mise en garde 1 Il est strictement interdit de taper sur les LED lorsqu elles sont allum es ou de provoquer des mouvements brusques ou des vibrations a la rampe en cours de fonctionnement 2 Le contr leur de la rampe doit tre plac dans un endroit sec et a r et ne devrait pas pouvoir tre clabouss 3 Respectez la tension d entr e 180VAC 245VAC www aquaportail com 4 L utilitaire d installation d clairage s il vous pla t lisez attentivement ce manuel pour viter de causer un dommage injustifi S il vous pla t conservez ce manuel en un acc s facile
5. www aquaportail com Merci de lire ce manuel d utilisation de la rampe d clairage pour aquarium MAXSPECT LED avant tout usage Instructions d emploi de l clairage MAXSPECT LED 3 W white light Flux lumineux 150 180 Im Temp rature de couleur 10000 K 3 W blue ray Principale longueur d onde optique 450 nm 30 W white light Flux lumineux 2000 Im Temp rature de couleur 18000 K L utilisateur doit d abord utiliser les instructions sur le r glage horaire en fonction des param tres du produit et seulement alors modifier les param tres usine si vous ne modifiez par les r glages usine le programme par d faut de la rampe LED est activ Les groupes de LED lumi re blanche et lumi re bleue peuvent tre r gl es ensembles ou s par ment mais les temps de commutation de chaque groupe ne peut fixer qu une seule heure de d but et un seul horaire d arr t 1 Time setting A Hold down the MODE button for more than 2 seconds to enter time setting mode B Begins flashing digital clock that is in the clock setting mode press WHITE or BLUE button set C And then click the MODE key to switch to the minute setting mode also based on a WHITE or BLUE button to set D Is set up according to TIMER button to return or more than 5 seconds does not operate automatically to return E Setting a good time the electronic clock work electronic clock error of the value of a year is less than 2

Download Pdf Manuals

image

Related Search

Related Contents

Actron CP7847 Operating Instructions  マックスクリーンボー3 レンタル契約書  2264-br 3 step ladere  User`s Manual - Auto Elektronika  ACTIMETRICS` LIMELIGHT3 VIDEO TRACKING USER`S MANUAL  LRP A3-RX  56 Ruling, Measuring - Visual Planning Group  

Copyright © All rights reserved.
Failed to retrieve file