Assist Rails L• WARNINGS SAVE THESE INSTRUCTIONS

image

Contents

1. Oe OY S Secure the crossbar to the right assist rail using two mounting bolts and locking washers NOTE Ensure that the tube is positioned above the mounting holes before tightening 9 Torque the bolts from STEPS 2 and 7 to 14 to 16 inch pounds Assist Rails 2 Part No 1130185 Left Assist Rail Mounting Bolt atient entrapment with bed side rails may cause injury or death Mattress must fit bed frame and side rails snugly to prevent patient entrapment Follow the manufacturer s instructions Monitor patient frequently Read and understand the Owner s Operator s Manual prior to using this equipment Manual is available at www invacare com or your dealer P PIN4190189 Rev A 11 04 Threaded lt oC a an ra O O Bushing Front View Left Assist Rail Side View Locking Washer Top Threaded Bushing Bolt Foot End of Bed Crossbar op Threaded Bushing Lower Threaded Locking Washer Mounting Bolt gt AY N 4 Ns Y ON f lt Left Side of Bed Right Side of Bed Crossbar Head End of Bed Installation FIGURE Assist Rails Part No 1130185 Operation NOTE For this procedure refer to FIGURE 2 NOTE The assist rails have three positions e Guard Down This position is intended to prevent an individual from inadvertently rolling out of
2. Install assist rails only in the pre punched mounting holes in the bed frame When mounted correctly the minimum distance between the assist rail in the assist up position and the head board will be appoximately 17 inches Mattress MUST fit bed frame and assist rails snugly to reduce the risk of entrapment Installation NOTE For this procedure refer to FIGURE 1 on page 3 NOTE Tools required 2 inch deep socket or use extension NOTE Assist rails are shipped in pairs one right and one left NOTE Right and left are determined by the user s position as if in the bed 1 Elevate the head section to allow access to the bed frame 2 On the left side of bed align the two top threaded bushings of the assist rail with the bed frame mounting holes 3 Secure the assist rail to the bed frame using two mounting bolts and locking washers A WARNING DO NOT use assist rails without crossbar installed Otherwise injury may result CAUTION Install the crossbar as shown in FIGURE Otherwise the crossbar will interfere with the pull tube of the motor possibly resulting in damage to the unit Align the crossbar with the lower threaded bushing of the left assist rail FIGURE 1 Secure the crossbar to the left assist rail using one mounting bolt and locking washers Repeat STEPS 1 and 2 for the right assist rail on the right side of the bed Align the crossbar with the lower threaded bushing of the right assist rail FIGURE 1
3. ET LE SEUL RECOURS AUX VIOLATIONS D UNE GARANTIE SERA LIMITE A LA REPARATION OU AU REMPLACEMENT DES PRODUITS DEFECTUEUX CONFORMEMENT AUX CONDITIONS ENONCEES DANS LES PRESENTES L APPLICATION DE TOUTE GARANTIE IMPLICITE NE SERA PAS PROROGEE AU DELA DE LA DUREE DE GARANTIE EXPRESSE ENONCEE DANS LES PRESENTES LE FABRICANT NE SERA PAS TENU RESPONSABLE DE TOUS DOMMAGES ACCIDENTELS OU CONSECUTIFS CETTE GARANTIE SERA CONSENTIE EN CONFORMITE AVEC LES LOIS PROVINCIALES OU DES ETATS ET LEURS EXIGENCES Part No 1130185 lI Rampes de lit Yes you can Invacare Corporation www invacare com USA One Invacare Way Elyria Ohio USA 44036 2125 800 333 6900 Canada 570 Matheson Blvd E Unit 8 Mississauga Ontario L4Z 4G4 Canada 800 668 5324 Invacare Yes you can and the Medallion Design are registered trademarks of Invacare Corporation 2005 Invacare Corporation Part No 1130185 Rev B 12 12 05
4. THE FOREGOING WARRANTY SHALL NOT APPLY TO SERIAL NUMBERED PRODUCTS IF THE SERIAL NUMBER HAS BEEN REMOVED OR DEFACED PRODUCTS SUBJECTED TO NEGLIGENCE ACCIDENT IMPROPER OPERATION MAINTENANCE OR STORAGE OR PRODUCTS MODIFIED WITHOUT INVACARE S EXPRESS WRITTEN CONSENT INCLUDING BUT NOT LIMITED TO MODIFICATION THROUGH THE USE OF UNAUTHORIZED PARTS OR ATTACHMENTS PRODUCTS DAMAGED BY REASON OF REPAIRS MADE TO ANY COMPONENT WITHOUT THE SPECIFIC CONSENT OF INVACARE PRODUCTS DAMAGED BY CIRCUMSTANCES BEYOND INVACARE S CONTROL PRODUCTS REPAIRED BY ANYONE OTHER THAN AN INVACARE DEALER SUCH EVALUATION SHALL BE SOLELY DETERMINED BY INVACARE THE FOREGOING EXPRESS WARRANTY IS EXCLUSIVE AND IN LIEU OF ANY OTHER WARRANTIES WHATSOEVER WHETHER EXPRESS OR IMPLIED INCLUDING THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE AND THE SOLE REMEDY FOR VIOLATIONS OF ANY WARRANTY WHATSOEVER SHALL BE LIMITED TO REPAIR OR REPLACEMENT OF THE DEFECTIVE PRODUCT PURSUANT TO THE TERMS CONTAINED HEREIN THE APPLICATION OF ANY IMPLIED WARRANTY WHATSOEVER SHALL NOT EXTEND BEYOND THE DURATION OF THE EXPRESS WARRANTY PROVIDED HEREIN THE MANUFACTURER SHALL NOT BE LIABLE FOR ANY CONSEQUENTIAL OR INCIDENTAL DAMAGES WHATSOEVER THIS WARRANTY SHALL BE EXTENDED TO COMPLY WITH STATE PROVINCIAL LAWS AND REQUIREMENTS Part No 1130185 5 Assist Rails Rampes de lit Instructions de montage d installation et d utilisation Mod le n 6632 Yes you
5. can CONSERVER CES INSTRUCTIONS REMARQUE Les rampes de lit 6632 doivent tre utilis es UNIQUEMENT avec les lits Invacare suivants 5410LOW 5410IVC 5410 5310IVC 5310 5307IVC 5307 et VC5310 REMARQUE V rifier toutes les pi ces avant l utilisation pour d tecter tout endommagement survenu lors du transport Si un dommage est constat NE PAS utiliser l quipement Contacter le distributeur transporteur pour obtenir d autres instructions Pour garantir l installation correcte et sans danger des rampes de lit ces instructions DOIVENT tre respect es MISES EN GARDE NE PAS installer ou utiliser cet quipement sans avoir au pr alable lu et bien compris ces instructions Si l utilisateur ne comprend pas bien les mises en garde messages d attention ou les instructions il doit contacter un professionnel de la sant le distributeur ou le personnel technique avant de tenter d installer cet quipement pour viter tout accident risquant d entra ner la mort une blessure ou un dommage mat riel Ces rampes de lit sont destin es emp cher le patient de tomber accidentellement en roulant hors du lit NE PAS utiliser pour restreindre les mouvements RISQUE DE PI GEAGE La surveillance et l valuation appropri es du patient et la maintenance et l utilisation appropri es de quipement doivent tre mises en uvre pour limiter le risque de pi geage Les variations de dimensions des barri re
6. 8 Part No 1130185 Rampe de lit gauche Le coincement du patient dans l espace entre les c t s de lit peut causer des blessures ou la mort Le matelas doit tre ajust au cadre et aux c t s du lit afin d emp cher que le patient reste coinc Conformez vous aux directives du fabricant Surveiller fr quemment le patient Lisez et assurez vous de bien comprendre le manuel d utilisation avant d utiliser cet quipement Le manuel en question est accessible www invacare com ou chez votre d taillant o Boulon de montage Douille filet e Rondelle de inf rieure Barre s curit transversale Vue frontale PIN 1143181 Rev A 04 17 06 Rampe de lit gauche LZ Rondelle de Douille filet e s curit sup rieure Douille filet e Vue lat rale sup rieure Douille filet e inf rieure Boulon Barre Pied de lit Rondelle de s curit Boulon de montage C t droit du lit T te de lit Barre FIGURE Installation Part No 1130185 9 Rampes de lit Fonctionnement REMARQUE Pour cette proc dure se reporter la FIGURE 2 de la page 10 REMARQUE Les rampes de lit ont trois positions e Protection vers le bas cette position est destin e emp cher le patient de rouler accidentellement hors du lit e Assistance vers le haut cette position aide le patient s asseoir ou se lever du lit e Ac
7. Assist Rails Assembly Installation and Operating Instructions Model No 6632 Yes you can SAVE THESE INSTRUCTIONS NOTE The 6632 Assist Rails are ONLY to be used with the following Invacare Beds 5410LOW 5410IVC 5410 5310IVC 5310 5307IVC 5307 and VC5310 NOTE Check all parts for shipping damage before using In case of damage DO NOT use the equipment Contact the dealer carrier for further instructions To ensure the safe and proper installation of the Assist Rails these instructions MUST be followed WARNINGS DO NOT install or use this equipment without first reading and understanding these instructions If you are unable to understand the Warnings Cautions or Instructions contact a healthcare professional dealer or technical personnel before attempting to install this equipment otherwise death injury or property damage may occur These assist rails are intended to prevent an individual from inadvertently rolling out of bed DO NOT use for restraint purposes ENTRAPMENT MAY OCCUR Proper patient assessment and monitoring and proper maintenance and use of equipment is required to reduce the risk of entrapment Variations in bed rail dimensions and mattress thickness size or density could increase the risk of entrapment Visit the FDA website at http www fda gov to learn about the risks of entrapment Review A Guide to Bed Safety published by the Hospital Bed Safety Workgroup located at
8. Cette garantie n est offerte qu l acheteur initial utilisateur final de nos produits La pr sente garantie conf re certains droits la l gislation du pays ou de la juridiction de l acheteur initial utilisateur final peut vous en accorder d autres Invacare garantit ce produit contre les vices de fabrication et de main d oeuvre aupr s de l acheteur initial pendant une p riode de deux ans Si ledit produit s av re d fectueux pendant cette p riode il sera r par ou remplac au choix d Invacare Cette garantie n inclut pas les frais de livraison ou de main d ceuvre r sultant de l installation de pi ces de rechange ou de la r paration dudit produit La seule obligation exclusive d Invacare et le seul recours exclusif du b n ficiaire de la garantie se limitera auxdites r parations et ou remplacements Pour un service au titre de la garantie l acheteur doit contacter le distributeur aupr s duquel il a achet le produit Invacare Si l acheteur ne juge pas le service de garantie satisfaisant il doit crire directement Invacare l adresse mentionn e ci dessous Fournir le nom du distributeur l adresse le num ro du mod le la date d achat indiquer la nature du d faut et le num ro du produit si celui ci est num rot en s rie Invacare Corporation enverra l acheteur une autorisation de retour Les pi ces ou l unit d fectueuses doivent tre retourn es pour l inspection de garantie en util
9. bed e Assist Up Assists the user in standing or sitting on bed e Access Back Allows unimpeded access to user NOTE When changing position of the assist rail hold and raise the rail with one hand while pulling the adjustment pin outward with the other hand 1 To change position of the assist rail perform one of the following A Guard Down Position Pull the adjustment pin and lower the assist rail down to the guard position There will be an audible Click when the assist rail locks into position B Assist Up Position Pull the adjustment pin and lift the assist rail up to the assist position There will be an audible Click when the assist rail locks into position NOTE The rail does not lock in the access position C Access Back Position Pull the adjustment pin and tilt the assist rail back towards the foot end of bed until assist rail stops Assist UP Position Access BACK aaa Position ey a ee Guard DOWN NC Position TOON DINN He N Foot End Cc Head End of Bed SRE of Bed Wor Adjustment Pin FIGURE 2 Operation Assist Rails 4 Part No 1130185 LIMITED WARRANTY PLEASE NOTE THE WARRANTY BELOW HAS BEEN DRAFTED TO COMPLY WITH FEDERAL LAW APPLICABLE TO PRODUCTS MANUFACTURED AFTER JULY 4 1975 This warranty is extended only to the original purchaser user of our products This warranty gives you specific legal rights and you may also have o
10. c s vers l arri re cette position permet d acc der sans obstacle au patient REMARQUE En changeant la position de la rampe de lit tenir et soulever la barri re d une main tout en tirant l axe de r glage vers l ext rieur avec l autre main 1 Pour changer la position de la rampe de lit effectuer l une de ces op rations A Position de protection vers le bas tirer l axe de r glage et abaisser la rampe de lit vers le bas en position de protection Un d clic retentit pour indiquer que la rampe est verrouill e en place B Position d assistance vers le haut tirer l axe de r glage et soulever la rampe de lit vers le haut en position d assistance Un d clic retentit pour indiquer que la rampe est verrouill e en place REMARQUE La barri re ne se verrouille pas en position d acc s C Position d acc s vers l arri re tirer l axe de r glage et incliner la rampe de lit en arri re vers le pied de lit jusqu l arr t de la rampe one sr Position d assistance Position d access a no k VERS LE HAUT VERS L ARRIERE Bie Position de protection VERS LE BAS Pied de lit T te de lit aoe Axe de r glage FIGURE 2 Fonctionnement Rampes de lit 10 Part No 1130185 GARANTIE LIMITEE REMARQUE IMPORTANTE LA GARANTIE CI DESSOUS A ETE ELABOREE CONFORMEMENT AUX LOIS FEDERALES AMERICAINES APPLICABLES POUR LES PRODUITS FABRIQUES APRES LE 4 JUILLET 1975
11. isant le num ro de s rie si applicable pour Pidentification dans les trente jours suivant la date d autorisation de retour NE PAS retourner les produits notre usine sans avoir obtenu notre accord pr alable Les livraisons contre remboursement seront refus es les livraisons doivent tre franco de port LIMITATIONS ET EXCLUSIONS LA GARANTIE NE S APPLIQUERA PAS AUX PROBL MES RESULTANT DE L USURE NORMALE OU DU NON RESPECT DES INSTRUCTIONS CI JOINTES DE PLUS LA GARANTIE QUI PRECEDE NE S APPLIQUERA PAS AUX PRODUITS NUMEROTES EN SERIE SI LE NUMERO DE SERIE A ETE SUPPRIME OU OBLITERE LES PRODUITS SOUMIS A UNE NEGLIGENCE A DES ACCIDENTS A UNE UTILISATION MAINTENANCE OU ENTREPOSAGE IMPROPRE OU LES PRODUITS MODIFIES SANS LE CONSENTEMENT ECRIT D INVACARE Y COMPRIS MAIS SANS S Y LIMITER LES MODIFICATIONS IMPLIQUANT L UTILISATION DE PIECES OU D ACCESSOIRES NON AUTORIS S LES PRODUITS ENDOMMAGES SUITE DES REPARATIONS EFFECTUEES SUR UN COMPOSANT QUELCONQUE SANS LE CONSENTEMENT FORMEL D INVACARE LES PRODUITS ENDOMMAGES DANS DES CIRCONSTANCES ECHAPPANT AU CONTROLE D INVACARE LES PRODUITS REPARES PAR TOUTE AUTRE PERSONNE QU UN DISTRIBUTEUR AGREE PAR INVACARE DONT L VALUATION SERA EXCLUSIVEMENT DETERMINEE PAR INVACARE LA GARANTIE EXPRESSE QUI PRECEDE EST EXCLUSIVE ET TIENT LIEU DE TOUTE AUTRE GARANTIE EXPRESSE OU IMPLICITE Y COMPRIS LES GARANTIES IMPLICITES DE COMMERCIALISATION ET D ADAPTATION A UN BUT PARTICULIER
12. it le patient dans le lit 1 Elever la section du dossier pour pouvoir acc der au cadre du lit 2 Sur le c t gauche du lit aligner les deux douilles filet es sup rieures de la rampe de lit avec les trous de montage sur le cadre Sad Fixer la rampe de lit au cadre en utilisant les deux boulons de fixation et rondelles de s curit A MISE EN GARDE NE PAS utiliser les rampes de lit sans avoir install la barre transversale afin d viter tout risque de blessure Part No 1130185 7 Rampes de lit ATTENTION Installer la barre transversale conform ment a la FIGURE I Sinon en g nant le tube de traction du moteur la barre transversale risque d endommager Punit 4 Aligner la barre transversale avec la douille filet e inf rieure de la rampe de lit gauche FIGURE 1 5 Fixer la barre transversale la rampe de lit gauche en utilisant un boulon de fixation et des rondelles de s curit 6 R p ter les tapes 1 et 2 pour la rampe droite du lit 7 Aligner la barre transversale avec la douille filet e inf rieure de la rampe de lit droite FIGURE 1 8 Fixer la barre transversale a la rampe de lit droite en utilisant deux boulons de fixation et des rondelles de s curit REMARQUE V rifier que le tube est align au dessus des trous de montage avant de serrer 9 Serrer les boulons de l tape 2 7 en appliquant un couple de 0 161294 0 184336 kgm 14 a 16 livres pouce Rampes de lit
13. s m dicales et l paisseur la taille ou la densit du matelas sont susceptibles d accro tre le risque de pi geage Visiter le site Web de la Food and Drug Administration FDA au http www fda gov pour en savoir plus sur les risques de pi geage Lire A Guide to Bed Safety Guide de s curit des lits publi par le comit sur la s curit des lits m dicaux Hospital Bed Safety Workgroup a www invacare com Utiliser le lien situ sous chaque entr e de barri res m dicales pour acc der a ce guide sur la s curit des lits Les produits Invacare sont sp cialement concus et fabriqu s pour tre utilis s conjointement avec les accessoires Invacare Les accessoires concus par d autres fabricants n ont pas t test s par Invacare et leur utilisation n est pas recommand e avec les produits Invacare For more information regarding Invacare products parts and services please visit www invacare com Rampes de lit 6 Part No 1130185 MISES EN GARDE M me si les rampes de lit ne sont pas homologu es pour une limitation pond rale sp cifique elles sont susceptibles de se d former ou de se briser si une pression lat rale excessive est exerc e contre elles Utilis es en position VERTICALE les rampes de lit sont destin es aider l utilisateur s asseoir ou monter ou descendre du lit Les rampes de lit ne doivent pas tre utilis es pour supporter tout le poids du patient NE PAS utiliser le
14. s rampes de lit en guise de poign es pour bouger le lit en vue de le d placer Apr s tout r glage r paration ou service et avant l utilisation s assurer que toutes les vis sont solidement fix es Les rampes de lit dont les dimensions sont diff rentes de quipement original fourni ou sp cifi par le fabricant du lit ne sont pas toujours interchangeables et sont susceptibles de provoquer un pi geage du patient ou d autres blessures V rifier que les tiges de r glage sont enti rement engag es avant d utiliser les positions de protection ou d assistance NE JAMAIS installer deux rampes sur un m me c t du lit La rampe de lit n est pas con ue pour tre utilis e avec une barri re suppl mentaire mont e sur le lit Installer le rampes de lit uniquement dans les trous de montage pr perfor s dans le cadre du lit Si le montage est correct la distance minimum entre la rampe de lit en position d assistance vers le haut et le dossier du lit doit tre d environ 43 cm Le matelas DOIT s ajuster troitement au cadre du lit et aux rampes pour r duire le risque de pi geage Installation REMARQUE Pour cette proc dure se reporter la FIGURE 1 de la page 9 REMARQUE Outils requis cl douille de 2 ou utiliser une rallonge REMARQUE Les rampes de lit sont livr es par paires une de droite et une de gauche REMARQUE Les c t s droit et gauche sont d termin s par la position qu occupera
15. ther legal rights which vary from state to state Invacare warrants its product to be free from defects in materials and workmanship for two years for the original purchaser If within such warranty period any such product shall be proven to be defective such product shall be repaired or replaced at Invacare s option This warranty does not include any labor or shipping charges incurred in replacement part installation or repair of any such product Invacare s sole obligation and your exclusive remedy under this warranty shall be limited to such repair and or replacement For warranty service please contact the dealer from whom you purchased your Invacare product In the event you do not receive satisfactory warranty service please write directly to Invacare at the address below Provide dealer s name address model number date of purchase indicate nature of the defect and if the product is serialized indicate the serial number Invacare Corporation will issue a return authorization The defective unit or parts must be returned for warranty inspection using the serial number when applicable as identification within thirty days of return authorization date DO NOT return products to our factory without our prior consent C O D shipments will be refused please prepay shipping charges LIMITATIONS AND EXCLUSIONS THE WARRANTY SHALL NOT APPLY TO PROBLEMS ARISING FROM NORMAL WEAR OR FAILURE TO ADHERE TO THE ENCLOSED INSTRUCTIONS IN ADDITION
16. www invacare com Use the link located under each bed rail product entry to access this bed safety guide Invacare products are specifically designed and manufactured for use in conjunction with Invacare accessories Accessories designed by other manufacturers have not been tested by Invacare and are not recommended for use with Invacare products Although assist rails are not rated to any specific weight limitation the assist rails may become deformed or broken if excessive side pressure is exerted on the side rails The assist rails when used in the UP position are designed to aid the user in sitting up or entering exiting the bed The assist rails should not be used to support the full weight of the user DO NOT use the assist rails as push handles when moving the bed After any adjustments repair or service and before use make sure all attaching hardware is tightened securely Assist rails with dimensions different from the original equipment supplied or specified by the bed manufacturer may not be interchangeable and may result in entrapment or other injury Ensure adjustment pins are fully engaged before using the guard or assist positions For more information regarding Invacare products parts and services please visit www invacare com Assist Rails l Part No 1130185 WARNINGS NEVER install two assist rails on the same side of the bed Assist rail is not designed to be used with any additional rail mounted to the bed