Home
PA barrier – PAP barrier
Contents
1. INSTRUCTIONS DE MONTAGE PAP POUR CABLE AVEC BLINDAGE KM 03 02 B INSTRUCTIONS DE MONTAGE PA POUR CABLE AVEC ET OU SANS BLINDAGE KM 1 2 ET KM 02 02 C INSTRUCTIONS DE MONTAGE PA BARRIER POUR CABLE AVEC ET OU SANS BLINDAGE KM 04 08 ET KM 05 08 3 LES EMERILLONS DU MODELE EXD IIC EXE II ET EXTD PEUVENT EGALEMENT ETRE UTILISES POUR DES CIRCUITS EXI SECURITE INTRINSEQUE 4 L INSTALLATION DOIT SE FAIRE CONFORM MENT AUX NORMES EN60079 14 EN60079 17 EN EN500281 1 2 MARQUAGE MARQUAGE ESTAMPE YSEBAERT KORALENHOEVE 13 B 2160 WOMMELGEM BELGIQUE TYPE PAP PA PAP PA BARRIER PAP BARRIER PAP BARRIER O N CE 0344 GROUPE Il 2 GD MODELE EXD IIC EXE Il EXTD A21 IP66 NUMERO DE SERIE ANNEE DE CONSTRUCTION INERIS O3ATEX0028 POUR DES PETITES ENTREES DE CABLE LE MARQUAGE ABREGE EST ADMIS YSEBAERT P CE 0344 Il 2 GD EXD IIC EEXE II EXTD INERIS 03ATEX0028 LES INFORMATIONS RESTANTES SE TROUVENT DANS LE MANUEL D UTILISATION ET OU SUR L EMBALLAGE APRES LA LETTRE P IL Y A DES LETTRES QUI INDIQUENT LE TYPE ET LE NUMERO DE MESURE DE FILETAGE ATTENTION L UTILISATEUR DOIT VERIFIER SI LA TEMPERATURE SUR LE LIEU DE MONTAGE DE L ENTREE DE CABLE EST DE MOINS DE 80 C L UTILISATION D UN EMERILLON DE DIMENSION 9 OU 10 POUR UN CABLE AVEC BLINDAGE EST LI E AUX CONDITIONS SUIVANTES L UTLISATEUR DOIT ATTACHER LE CABLE D UNE MANIERE APPROPRI E ET L INSTALLATION D
2. A barrier PAP barrier PPAP barrier af KABELPAKDASER KORT SAGT SIKKERHEDSKRITERIERNE ER FOLGENDE GRUPPE II KATEGORI GD UDSTYR BEREGNET TIL INDUSTRIEN FOR OVERFLADEBHANDLING HVOR DER FOREFINDES GASARTER DAMPE OG EKSPLOSIVT ST V Exd IIC Exe Il ExtD MODELLER OMGIVENDE TEMPERATUR 20 C 80 C MEKANISK SIKKERHED IP66 DETTE ER FULDSTAENDIG OVERENSSTEMMELSE MED ATEX DIREKTIV 94 9 EC SOM OMFATTER ALLE SYSTEMER DER ER BEREGNEDE TIL BRUG PA STEDER MED UDPR GET EKSPLOTIONSFARE BEM RKNINGER TIL MONT REN 1 KABELPAKD SERNE ANVENDES TIL KABLER MED METALFORST RKNING OMFLETTEDE ELLER METALLEDNINGER OG TIL KABLER UDEN FORST RKNING 2 F LG OMHYGGELIGT DE INSTRUKTIONER DER F LGER MED HVER FORSENDELSE S DE SAMLES KORREKT a SAMLEINSINSTRUKSER PAP for KM 03 02 forst rket kabel b SAMLEINSTRUKSER PA for kabler med og uden forst rkning KM 1 2 og KM 02 02 c SAMLEINSTRUKSER PA barrier for kabler med og uden forst rkning KM 04 08 og KM 05 08 3 KABELPAKD SERNE I MODELLERNE Exd IIC Exe II OG ExtD KAN DESUDEN ANVENDES MED Exi kredsl b indre sikkerhed 4 INSTALLATIONERNE SKAL V RE I OVERENSSTEMMELSE MED STANDARDERNE EN60079 14 EN60079 17 OG EN500281 1 2 M RKNING PR GET M RKNING PRODUCENTENS NAVN YSEBAERT KORALENHOEVE 13 2160 WOMMELGEM BELGIUM TYPE PAP PA PPAP PA barrier PAP barrier PPAP barrier O N CE 0344 GRUPPE Il 2 GD MODEL Ex
3. ARA CABLE CON O SIN BLINDAJE KM 04 08 Y KM05 08 3 LOS ESLABONES GIRATORIOS DEL MODELO Exd IIC Exe II ET ExtD TAMBIEN PUEDEN SER UTILIZADOS PARA CIRCUITOS EXI SEGURIDAD INTRINSECA 4 LA INSTALACI N DEBE HACERSE CONFORME A LAS NORMAS EN60079 14 EN60079 17 EN EN500281 1 2 MARCADO MARCADO ESTAMPADO NOMBRE DEL CONSTRUCTOR YSEBAERT KORALENHOEVE 13 2160 WOMMELGEM BELGIUM TIPO PAP PA PPAP PA BARRIER PAP BARRIER PPAP BARRIER O N CE 0344 GRUPO II 2 GD MODELO Exd IIC Exe II ExtD A21 IP66 Ex NUMERO DE SERIE ANO DE CONSTRUCCI N LABORATORIO Y NUMERO DE CERTIFICADO INERIS 03ATEX0028 PARA PEQUENAS ENTRADAS DE CABLE SE ADMITE EL MARCADO ABREVIADO YSEBAERT P CE 0344 Ex Il 2 GD Exd IIC Exe Il ExtD INERIS 03ATEX0028 LAS DEMAS INFORMACIONES SE ENCUENTRAN EN LA GUIA DE UTILIZACION Y O EN EL EMBALAJE DESPU S DE LA LETRA P HAY LETRAS QUE INDICAN EL TIPO Y EL NUMERO DE MEDIDA DE ROSCA DE TORNILLO OJO EL USUARIO DEBE COMPROBAR SI LA TEMPERATURA DONDE SE MONTA LA ENTRADA DE CABLE ES INFERIOR A 80 C LA UTILIZACION DE UN ESLABON GIRATORIO DE DIMENSION 9 O 10 PARA UN CABLE CON BLINDAJE DEPENDE DE LAS SIGUIENTES CONDICIONES EL USUARIO DEBE SUJETAR EL CABLE DE UN MODO ADECUADO Y LA INSTALACION DEBE ESTAR FIJA 36 BRUGSVEJLEDNING TIL KABELPAKDASER HENHOLD TIL ATEX DIREKTIVET 94 9 EC SAMLINGSINSTRUKTIONER TIL serierne PA PAP PPAP P
4. AUBENGEWINDEMAB ANGEBEN ACHTUNG DER BENUTZER SOLL UBERPRUFEN OB DIE TEMPERATUR AN DER MONTAGESTELLE DES KABELEINGANGS WENIGER ALS 80 C BETRAGT DIE VERWENDUNG EINER STOPFBUCHSE IN DER ABMESSUNG 9 ODER 10 FUR EIN PANZERKABEL HANGT VOM NACHSTEHENDEN AB DER BENUTZER BEFESTIGT DAS KABEL IN ANGEMESSENER WEISE UND SCHRAUBT DIE ANLAGE FEST 5 INSTRUCCIONES DE USO DE ESLABONES GIRATORIOS DE CONFORMIDAD CON LA DIRECTIVA ATEX 94 9 CE INSTRUCCIONES DE MONTAJE DE LOS ESLABONES GIRATORIOS SERIE PA PAP PPAP PA BARRIER PAP BARRIER PPAP BARRIER LAS CARACTERISTICAS DE SEGURIDAD SE RESUMEN COMO SIGUEN GRUPO II CATEGORIA GD MATERIAL DESTINADO A LA INDUSTRIA DE SUPERFICIE CON PRESENCIA DE GAS VAPORES Y MATERIA EXPLOSIVA MODELO Exd IIC Exe II ExtD TEMPERATURA AMBIENTE 20 C 80 C PROTECCION MECANICA IP66 TODO ELLO EN TOTAL ACUERDO CON LA DIRECTIVA ATEX 94 9 CE PARA TODOS LOS SISTEMAS DESTINADOS A SER UTILIZADOS EN LUGARES CON PELIGROS DE EXPLOSION NOTAS PARA EL INSTALADOR 1 LOS ESLABONES GIRATORIOS SE UTILIZAN PARA CABLES TRENZADOS DE HILOS O DE HILOS METALICOS CON UN BLINDAJE METALICO Y PARA CABLES SIN BLINDAJE 2 PARA MONTARLOS CORRECTAMENTE SIGA ATENTAMENTE LAS INSTRUCCIONES QUE SE ENTREGAN CON CADA PRODUCTO A INSTRUCCIONES DE MONTAJE PAP PARA CABLE CON BLINDAJE KM 03 02 B INSTRUCCIONES DE MONTAJE PA PARA CABLE CON O SIN BLINDAJE KM 1 2 Y KM 02 02 C INSTRUCCIONES DE MONTAJE PA BARRIER P
5. EN EXPLOSIONSGEFAHR HERRSCHT INSTALLATIONSVORSCHRIFTEN 1 DIE STOPFBUCHSEN WERDEN FUR KABEL MIT EINER METALLPANZERUNG AUS GEFLOCHTENEM DRAHT ODER METALLDRAHT SOWIE FUR UNGEPANZERTE KABEL VERWENDET 2 FUR EINE KORREKTE MONTAGE BEFOLGEN SIE DIE BEI JEDER SENDUNG MITGELIEFERTEN ANWEISUNGEN a MONTAGEANWEISUNGEN PAP fur Panzerkabel KM 03 02 b MONTAGEANWEISUNGEN PA fur Panzerkabel und oder ungepanzerte Kabel KM 1 2 und KM 02 02 c MONTAGEANWEISUNGEN PA barrier fur Panzerkabel und oder ungepanzerte Kabel KM 04 08 und KM 05 08 3 DIE STOPFBUCHSEN IN DER AUSFUHRUNG Exd IIC Exe II UND ExtD KONNEN AUCH BEI Exi Kreisen Eigensicherheit VERWENDET WERDEN 4 DIE MONTAGE ERFOLGT ENTSPRECHEND DEN NORMEN EN60079 14 EN60079 17 UND EN500281 1 2 KENNZEICHNUNG EINGEPRESSTE MARKIERUNG YSEBAERT KORALENHOEVE13 B 2160 WOMMELGEM BELGIUM TYP PAP PA PPAP PA barrier PAP barrier PPAP barrier CE ZEICHEN CE 0344 GRUPPE Il 2 GD AUSFUHRUNG Exd IIC EXe Il ExtD A21 IP66 Seriennummer Baujahr INSTITUT UND ZERTIFIKATSNUMMER INERIS O3ATEX0028 BEI KLEINEN KABELEINGANGEN IST DIE KURZKENNZEICHNUNG ZUGELASSEN YSEBAERT P CE 0344 II 2 GD Exd IIC Exe II ExtD Ex INERIS 03ATEX0028 DIE UBRIGEN INFORMATIONEN FINDEN SICH IN DER GEBRAUCHSANWEISUNG UND ODER AUF DER VERPACKUNG NACH DEM BUCHSTABEN P STEHEN DIE BUCHSTABEN DIE DEN TYP SOWIE DAS SCHR
6. OIT ETRE FIXEE zd INSTRUCTIONS FOR THE USE OF CABLE GLANDS INACCORDANCE WITH ATEX DIRECTIVE 94 9 EC INSTRUCTIONS FOR THE ASSEMBLY OF PA PAP PPAP PA barrier PAP barrier PPAP barrier series IN SUMMARY THE SAFETY CHARACTERISTICS ARE GROUP II CATEGORY GD EQUIPMENT DESTINED FOR THE SURFACE INDUSTRY WITH PRESENCE OF GAS VAPOURS AND EXPLOSIVE DUST Exd IIC Exe II ExtD MODELS AMBIENT TEMPERATURE 20 C 80 C MECHANICAL SAFETY IP66 THIS IS IN FULL COMPLIANCE WITH ATEX DIRECTIVE 94 9 EC FOR ALL SYSTEMS INTENDED FOR USE IN PLACES WITH A HIGH RISK OF EXPLOSION NOTES FOR THE INSTALLER 1 THE CABLE GLANDS ARE USED FOR CABLES WITH METAL REINFORCEMENT BRAIDED OR METAL WIRE AND FOR NON REINFORCED CABLES 2 FOR A PROPER ASSEMBLY CAREFULLY FOLLOW THE INSTRUCTIONS INCLUDED WITH EVERY SHIPMENT a ASSEMBLY INSTRUCTIONS PAP for KM 03 02 reinforced cable b ASSEMBLY INSTRUCTIONS PA for reinforced and or non reinforced cables KM 01 02 and KM 02 02 c ASSEMBLY INSTRUCTIONS PA barrier for reinforced and or non reinforced cables KM 04 08 and KM 05 08 3 THE Exd IIC Exe II AND ExtD CABLE GLAND MODELS CAN ALSO BE USED WITH Exi circuits intrinsic safety 4 THE INSTALLATIONS MUST COMPLY WITH THE EN60079 14 EN60079 17 AND EN500281 1 2 STANDARDS MARKING EMBOSSED MARKING YSEBAERT Koralenhoeve 13 2160 Wommelgem Belgium TYPE PAP PA PPAP PA barrier PAP bar
7. YYSEBAERT Ce PA PAP PPAP PA barrier PAP barrier PPAP barrier NL Instructies voor het gebruik van Instructies wartels conform richtlijn ATEX Conformiteitsverklaring 94 9 EG F Notice d utilisation des presse Notice d utilisation toupes conform ment la directive D claration CE de conformit ATEX 94 9 CE E Instructions for the use of cable Instructions for use glands in accordance with ATEX EC Declaration of Conformity directive 94 9 EC D Gebrauchsanweisungen f r Gebrauchsanweisungen Stopfbuchsen entsprechend der Konformitatserklarung Richtlinie ATEX 94 9 EG S Instrucciones de uso de eslabones Instrucciones de uso giratorios de conformidad con la Declaraci n de conformidad directiva ATEX 94 9 CE DK Brugsvejledning til pakdaser i Brugsvejledning henhold til ATEX direktivet 94 9 EC Komformitetserkl ring Note EC type examination certificat INERISO3ATEX0028 can be downloaded from our site www ysebaert be YSEBAERT NV Koralenhoeve 13 B 2160 Wommelgem Tel 32 0 3 328 06 60 Fax 32 0 3 328 06 80 www ysebaert be info ysebaert be D04 20 1310 INSTRUCTIES VOOR HET GEBRUIK VAN WARTELS CONFORM RICHTLIJN ATEX 94 9 EG Instructies voor de montage van wartels reeks PA PAP PPAP PA barrier PAP barrier PPAP barrier DE VEILIGHEIDSKENMERKEN WORDEN ALS VOLGT SAMENGEVAT Materiaal bestemd voor bovengrondse nijverheid met aanwezigheid van gas dampen en explosi
8. d IIC Exe Il ExtD A21 IP66 SERIENUMMER FREMSTILLINGSAR LABORATORIUM OG NUMMERCERTIFIKAT INERIS 03ATEX0028 DEN KORTE M RKNING ER TILLADT TIL SM KABELINDGANGE YSEBAERT P CE 0344 II 2 GD Exd IIC Exe II ExtD Ex INERIS O3ATEX0028 ALLE ANDRE OPLYSNINGER KAN FINDES BRUGERVEJLEDNINGEN OG ELLER PA EMBALLAGEN BOGSTAVET P EFTERF LGES AF BOGSTAVER DER MARKERER TYPE OG ST RRELSENS NUMMER BEM RK DET ER BRUGERENS PLIGT AT AFG RE OM TEMPERATUREN P DET STED HVOR KABELINDGANGEN SAMLES ER MINDRE END 80 C BRUGEN AF KABELPAKD SE I ST RRELSE 9 ELLER 10 TIL ET FORST RKET KABEL AFH NGER AF F LGENDE BETINGELSER BRUGEREN SKAL FASTG RE KABLET KORREKT OG SELVE INSTALLATIONEN SKAL V RE FASTGJORT c7 YYSEBAERT EC DECLARATION OF CONFORMITY We YSEBAERT N V Koralenhoeve 13 2160 Wommelgem Belgium Declare under our sole responsibility that the product Cable glands type P and P BARRIER to which this declaration relates is in conformity with the following standards EN 60079 0 2006 EN 60079 1 2004 EN 60079 7 2003 EN 61241 0 2006 EN 61241 1 2004 following the provisions of Directives 94 9 EC and 89 336 EC EC type examination certificate INERIS O3ATEX0028 Addition No 01 INERIS notified body no 0080 B P N 2 60550 Verneuil en Halatte France Wommelgem 01 10 2013
9. ef stof GROEP II CATEGORIE GD Uitvoering Exd IIC Exe II ExtD Omgevingstemperatuur 20 C 80 C Mechanische beveiliging IP66 Dit alles volledig in overeenstemming met de richtlijn ATEX 94 9 EG voor alle systemen bedoeld voor gebruik op plaatsen waar ontploffingsgevaar kan heersen NOTA S VOOR DE INSTALLATEUR 1 De wartels worden gebruikt voor kabels met metalen pantsering gevlochten uit draad of metaaldraad en voor ongepantserde kabels 2 Volg voor een correcte montage nauwkeurig de instructies die worden meegeleverd met elke zending a Montage instructies PAP voor gepantserde kabel KM 03 02 b Montage instructies PA voor gepantserde en of ongepantserde kabel KM 1 2 en KM 02 02 c Montage instructies PA barrier voor gepantserde en of ongepantserde kabel KM 04 08 en KM 05 08 3 De wartels in de uitvoering Exd IIC Exe II en ExtD kunnen ook worden gebruikt bij Exi circuits intrinsieke veiligheid 4 De installatie moet gebeuren conform de normen EN60079 14 EN60079 17 en EN500281 1 2 MARKERING INGEPERSTE MARKERING YSEBAERT Koralenhoeve 13 B 2160 Wommelgem Belgium TYPE PAP PA PPAP PA barrier PAP barrier PPAP barrier O N CE 0344 GROEP Il 2 GD UITVOERING Exd IIC Exe Il ExtD A21 IP66 Ex Serienummer Bouwjaar LABORATORIUM EN NUMMER CERTIFICAAT INERIS OSATEXOO28 Bij kleine kabelingangen is de verkorte markering toegelaten YSEBAERT pu
10. rier PPAP barrier O N CE 0344 GROUP II 2 GD MODEL Exd IIC Exe II ExtD A21 IP66 SERIAL NUMBER YEAR OF CONSTRUCTION LABORATORY AND NUMBER CERTIFICATE INERIS OSATEXO028 THE SHORT MARKING IS ALLOWED FOR SMALL CABLE INLETS YSEBAERT B P CE 0344 II 2 GD Exd IIC Exe II ExtD INERIS O3ATEX0028 ANY OTHER INFORMATION CAN BE FOUND IN THE USER MANUAL AND OR ON THE PACKAGING THE LETTER P IS FOLLOWED BY LETTERS INDICATING THE TYPE AND NUMBER OF THE SIZE PLEASE NOTE THE USER MUST VERIFY WHETHER THE TEMPERATURE AT THE LOCATION WHERE THE CABLE INLET IS ASSEMBLED IS BELOW 80 C THE USE OF A CABLE GLAND SIZE 9 OR 10 FOR A REINFORCED CABLE DEPENDS ON THE FOLLOWING CONDITIONS THE USER MUST PROPERLY ATTACH THE CABLE AND THE INSTALLATION MUST BE FASTENED 4 GEBRAUCHSANWEISUNGEN FUR STOPFBUCHSEN ENTSPRECHEND DER RICHTLINIE ATEX 94 9 EG ANWEISUNGEN FUR DIE MONTAGE VON STOPFBUCHSEN DER SERIE PA PAP PPAP PA barrier PAP barrier PPAP barrier DIE SICHERHEITSMERKMALE LASSEN SICH FOLGENDERMABEN ZUSAMMENFASSEN GRUPPE II KATEGORIE GD AUSR STUNG ZUR VERWENDUNG AUBERHALB VOM BERGBAU BER TAGE IN BEREICHEN IN DENEN GAS DAMPFE UND EXPLOSIONSFAHIGER STAUB VORHANDEN SIND AUSF HRUNG Exd IIC Exe Il ExtD UMGEBUNGSTEMPERATUR 20 C 80 C SCHUTZART IP66 OBENSTEHENDES IN UBEREINSTIMMUNG MIT DER RICHTLINIE ATEX 94 9 EG FUR SYSTEME DIE AN STELLEN VERWENDET WERDEN AN DEN
11. s CE 0344 I 2 GD Exd IIC Exe II ExtD INERIS OSATEX0028 De overige informatie is terug te vinden in de gebruikshandleiding en of op de verpakking Na de letter P staan letters die het type aanduiden en het nummer van de schroefdraadmaat Opgelet de gebruiker moet nagaan of de temperatuur op de montageplaats van de kabelingang minder dan 80 c bedraagt Het gebruik van een wartel maat 9 of 10 voor een gepantserde kabel hangt af van de volgende voorwaarden de gebruiker moet de kabel op gepaste wijze vastmaken en de installatie moet worden vastgezet 2 NOTICE D UTILISATION DES PRESSE ETOUPES CONFORMEMENT A LA DIRECTIVE ATEX 94 9 CE Notice de montage des presse toupes serie PA PAP PPAP PA barrier PAP barrier PPAP barrier LES CARACTERISTIQUES DE SECURITE SE RESUMENT AINSI GROUPE II CATEGORIE GD MATERIEL DESTINE A L INDUSTRIE DE SURFACE AVEC PRESENCE DE GAZ VAPEURS ET MATIERE EXPLOSIVE MODELE EXD IIC EXE II EXTD TEMPERATURE AMBIANTE 20 C 80 C PROTECTION MECANIQUE IP66 LE TOUT CECI EN ACCORD COMPLET AVEC LA DIRECTIVE ATEX 94 9 CE POUR TOUS LES SYSTEMES DESTINES A L UTILISATION DANS DES ENDROITS AVEC DES RISQUES D EXPLOSION NOTES POUR L INSTALLATEUR 1 LES EMERILLONS SONT UTILISES POUR DES CABLES TRESSES DE FILS OU DE FILS METALLIQUES AVEC BLINDAGE METALLIQUE ET POUR DES CABLES SANS BLINDAGE 2 POUR UN MONTAGE CORRECT SUIVEZ ATTENTIVEMENT LA NOTICE FOURNIE CHAQUE LIVRAISON A
Download Pdf Manuals
Related Search
Related Contents
Ryobi OLT1831 HP LaserJet Pro M127fn Mode d'emploi Manuel d`utilisation Thermomètre infrarouge de poche Modèle IR201A StarTech.com DisplayPort 1.2 cable with latches – certified, 10 ft StarTech.com 10m High Speed HDMI® Cable – Ultra HD 4k x 2k HDMI Cable – HDMI to HDMI M/M DuPont™ Altacor® Insecticide Fiche Signalétique Sony SVL24118FXB Marketing Specifications User Manual Descargar Manual de Usuario Copyright © All rights reserved.