1. Utilisation et entretien Pour l utilisation et l entretien veuillez se r f rer au manuel d utilisation et d entretien qui est aussi joint a la hotte ou visiter notre site internet www arouatek com 10 PK 4002 Rev 2 Notes Thinking environment Many documents are not provided with the range hood but are available in our website www arouatek com We invite you to visit it Pensons environnement Plusieurs documents ne sont pas fournis avec la hotte mais sont disponibles lectroniquement sur notre site Internet www arouatek com Nous vous invitons le consulter Zifroua Un air distinctif A distinctive air This book was written to help you to install your new range hood For more information please call 1 877 561 6454 or visit www arouatek com Ce Document a t tabli pour vous aider a bien installer votre nouvelle hotte de cuisine Pour toute autre information nous vous invitons a nous appeler au 1 877 561 6454 ou visiter www arouatek com PK 4002 Rev 2 12
2. Installation Instructions Range hood Hotte de cuisine Aroua Vortix Vr201 BL Un air distinctif A distinctive air For your Safety Pour Votre s curit Before you begin This range hood was designed for a domestic purpose WARNING TO REDUCE THE RISK OF FIRE ELECTRIC SHOCK OR INJURY TO PERSONS OBSERVE THE FOLLOWING a Installation work and electrical wiring must be done by qualified person s in accordance with all applicable codes and standards including fire rated construction b Sufficient air is needed for proper combustion and exhausting of gases through the flue chimney of fuel burning equipment to prevent back drafting Follow the heating equipment manufacturer s guideline and safety standards such as those published by the National Fire Protection Association NFPA and the American Society for Heating Refrigeration and Air Conditioning Engineers ASHRAE and the local code authorities c When cutting or drilling into wall or ceiling do not damage electrical wiring and other hidden utilities d Ducted fans must always be vented to the outdoors e Do not use any external speed control devices f This unit must be grounded properly to avoid any electrical shock WARNING TO REDUCE THE RISK OF FIRE USE ONLY METAL DUCTWORK WARNING TO REDUCE THE RISK OF A RANGE TOP GREASE FIRE a Never leave surface units unattended at high settings Boilovers cause smoking
3. PK 4002 Rev 2 Contenu COM ene emerge eee 4 DIMENSIONS a as nu 4 Avant l installation 6 Accessoires pour conduites 7 Outils n cessaires cee eeeeeeeceeeceeceeeceecaeeeeeees 8 Extraction de la hotte 8 Contenu de la bo te ou eeeeccecceeceeeeeeeeeeeeeeene 8 Pr parer la cabine d installation 10 Branchement lectrique 9 Installer l unit centrale de la hotte de cuisine Re E Erreur Signet non d fini Installation des filtres c ccececececeeeeeeess 10 Utilisation et entretien 10 L 35 5 cm 14 13 6 cm 5 35 40 cm 15 75 La hotte doit tre install e 65cm 24 1 2 min et 75cm 29 1 2 max au dessus de la surface de cuisson Cette hotte a t con ue pour des plafonds de hauteur de 8 pieds Suivre ce manuel d installation vous permettra de garantir le respect des exigences li es la distance s parant le dessous de la hotte de cuisine la table de cuisson Installation preparation Preparation de l installation Information oe es Information This range hood Cette hotte ne works in an air fonctionne qu en exhausting mode mode d extraction d aire et ne permet pas le eae recyclage Conduit 3 1 4 x 10 Cl dd dd dd A NI N A TT g oO D D Q oO 2 a 5 A and should not be used in an air recycling installation Hotte Vr201 Range hood 65 75 cm 25 1 2 29 1 2 A Avertissemen
4. and greasy spillovers that may ignite Heat oils slowly on low or medium settings b Always turn hood ON when cooking at high heat or when flambeing food i e Crepes Suzette Cherries Jubilee Peppercorn Beef Flambe c Clean ventilating fans frequently Grease should not be allowed to accumulate on fan or filter d Use proper pan size Always use cookware appropriate for the size of the surface element WARNING TO REDUCE THE RISK OF INJURY TO PERSONS IN THE EVENT OF A RANGE TOP GREASE FIRE OBSERVE THE PK 4002 Rev 2 Avant de commencer Cette hotte a t con ue pour un usage domicile AVERTISSEMENT AFIN DE R DUIRE LE RISQUE D INCENDIE D ELECTROCUTION OU DE BLESSURES CORPORELLES OBSERVEZ CE QUI SUIT a L installation et la connexion lectrique doit tre faite par une des personne s qualifi e s en conformit avec les codes et normes du b timent applicables en mati re de pr vention d incendie b Une circulation d air efficace est requise afin d assurer la combustion et l vacuation complete des gaz par la chemin e des quipements combustion pour pr venir les retours de chemin e Conformez vous aux instructions et aux standards de s curit des manufacturiers d quipement de chauffage tels qu ils sont publi s par la National Fire Protection Association NFPA et l American Society for Heating Refrigeration and Air Conditioning Engineers ASHRAE ainsi que les responsable
5. SSEMENT AFIN D EVITER TOUT RISQUE DE BLESSURES LORS D UN FEU DE CUISINIERE OBSERVEZ LES DIRECTIVES SUIVANTES a TOUFFEZ LES FLAMMES avec un couvercle herm tique une t le biscuits ou un plateau m tallique puis teignez le br leur ATTENTION DE NE PAS VOUS BRULER Si les flammes ne s teignent pas imm diatement SORTEZ ET APPELEZ LES POMPIERS b NE PRENEZ JAMAIS EN MAIN UNE POELE OU UNE CASSEROLE QUI A PRIS FEU Vous pourriez vous br ler c N UTILISEZ PAS D EAU ni de linge a vaisselle ou de serviette mouillee cela pourrait occasionner une violente explosion de vapeur d N utiliser un extincteur que si 1 Vous savez qu il s agit d un extincteur de classe ABC et que vous en connaissez le fonctionnement 2 L incendie est petit et limit endroit o il a d but 3 Les pompiers ont t avis s 4 Vous pouvez combattre l incendie en ayant acc s une sortie de secours Extr e du Kitchen Fire Safety Tips publi par la NFPA ATTENTION L installateur doit garder ce document chez le client Le client doit garder ce document dans un milieu sur pour de futures r f rences La personne qui installe cette hotte doit avoir des connaissances minimales en m canique et en lectricit Toute d faillance suite une mauvaise installation est non couverte par la garantie offerte La dur e d installation peut prendre de 1 3 heures cause du poids de la hotte deux per
6. es conduites pour calculer les longueurs permises pour chacun d eux voir page suivante N utiliser que des conduites en m tal Avertissement Pour viter tout risque de feu assurez vous que la conduite d air permet d vacuer l air vers l ext rieur et non dans un endroit clos ayant un plafond ou des murs Installation preparation Preparation de l installation Conducts accessories Depending on the installation configuration you will need a combination of the following conduct accessories 6 round straight Straight 3 1 4 x 12 3 1 4 x 24 6 Round 90 elbow 3 1 4 x 12 90 elbow 6 round to 3 1 4 x 12 trans 6 round to 3 1 4 x 12 trans 90 elbow 6 round wall cap with damper 3 1 4 x 12 wall cap with damper 6 round roof cap Warning Only metallic conduct should be installed Accessoires pour conduites Selon le type d installation que vous aller faire vous aurez besoin d une combinaison des accessoires de conduites suivants PK 4002 Rev 2 Conduite ronde de 6 de diam tre Conduite rectangulaire Coude de 90 de 6 de diam tre Coude 90 rectangulaire 3 1 4 x 12 Convertisseur rond 6 au rectangulaire 3 1 4 x 12 Coude convertisseur 90 de circulaire 6 au rectangulaire 3 1 4 x 12 Sortie murale ronde 6 couvercle Sortie murale rectangulaire 3 1 4 x 12 couvercle Sortie de toiture ronde 6 Avertissement Toutes les c
7. king Note This step will need two persons Make sure that the backdraft damper is well connected to the home ducting when sliding the insert into the cabinet Preparer la cabine d installation La cabine sur mesure doit respecter les dimensions de la hotte pour permettre son installation et doit tre capable de supporter un poids de 25 Kg Fixer solidement les bars de bois voir figure ci dessous Glisser la hotte encastr e jusqu a sa position d installation s assurer qu il ny a aucun espace entre la hotte et le dessous de la cabine Fixer la hotte par les 7 vis fournis S assurer que la hotte est bien fix e et qu aucun mouvement de vibration ne pourrait tre engendr lors du fonctionnement Note Cette op ration va n cessiter deux personnes S assurer durant l installation que le clapet est bien connect aux conduits d air de la maison Wooden bars bars de bois Filters installation Two filters in stainless steel are provided with the range hood They are easy to install and remove and is subject of maintenance see the use and care manual Use and Care Please refer to Use amp Care Manual joined as well to the range hood or visit our website www arouatek com PK 4002 Rev 2 Installation des filtres Deux filtres en acier inoxydable sont fournis avec la hotte Ils sont faciles a installer et desinstaller et sont sujet d entretien voir le manuel utilisation et entretien
8. lose fitting lid cookie sheet or metal tray then turn off the burner BE CAREFUL TO PREVENT BURNS If the flames do not go out immediately EVACUATE AND CALL THE FIRE DEPARTMENT b NEVER PICK UP A FLAMING PAN You may be burned c DO NOT USE WATER including wet dishcloths or towels a violent steam explosion will result d Use an extinguisher ONLY if 1 You Know you have a Class ABC extinguisher and you already know how to operate it 2 The fire is small and contained in the area where it started 3 The fire department is being called 4 You can fight the fire with your back to an exit Based on Kitchen Firesafety Tips published by NFPA CAUTION e The installer should keep this document with the customer The customer should keep this document in a safe place for future purposes The person who will install this range hood should have a minimum of mechanical and electrical skills Any deficiency following an incorrect installation is not covered by the original warranty The estimated time to install this range hood is 1 to 3 hours Because of the weight of the range hood 2 installers are recommended The range hood moior is equipped with a thermal overload switch which will automatically shut off the motor if it becomes overheated The motor will restart when it will cool down If the motor continues to shut off and restart have the hood serviced PK 4002 Rev 2 AVERTI
9. onduites doivent tre m talliques Installation preparation Preparation de l installation Necessary tools During the installation you will need the following tools e Screw driver set e Measuring tape e Water level e Electrical Drill e Hammer e Conducts tape Unpacking the box The range hood is packed in a safe manner to insure its integrity during the transportation Unpacking is also a critical task and could damage the range hood Make sure the box is on its bottom side before starting unpacking refer to the signs on the box Open the box and start to take out all the components safely Box content Insert main unit Unit centrale de la hotte encastr e Bacvkdraft damper Sortie a clapet PK 4002 Rev 2 Outils n cessaires Les outils que vous aurez besoin pour l installation de votre hotte sont Jeu de tournevis Metre ruban Scie lectrique Perceuse lectrique Marteau Ruban adh sif pour conduites Extraction de la hotte La hotte est emball e de mani re s curitaire pour assurer son int grit durant le transport N anmoins lextraction la hotte reste une op ration qui pourrait endommager S assurer que la bo te est pos e sur sa face de dessous avant le d bo tage se r f rer aux indications sur la bo te Ouvrer la bo te et commencer sortir toutes les composantes Contenu de la bo te Cr L 7 Wood screws 7 vis bois 2 filte
10. rs 2 filtres Cord grip Collet de fixation c ble Installation steps tapes de l installation Electrical plugging Warning Before commencing this step check if the breaker is opened and that no electrical current can bein the installation s wires Branchement electrique Avertissement Avant de commencer installation v rifier si le disjoncteur est bel et bien ouvert et qu aucun courant lectrique ne circule dans l installation Reminder This range hood works on 120VAC Remove the inside cover by unscrewing the 4 screws Mount the cable grip the screws in the outside face on the big hole and introduce through it the home electrical cable Using the provided connectors connect the black home electrical wire to the black hood electrical wire the white home electrical wire to the white hood electrical wire and the ground home electrical wire to the green hood electrical wire Tight the home electrical cable by using the 2 screws and remount the inside cover with the 4 screws Once the home cable is connected install the backdraft damper to the fan s outlet and seal the connection line by a tape Note check the direction of the backdraft damper so that to allow the air to move from the fan to the outside Inside cover Cache interne PK 4002 Rev 2 a IS Rappel cette hotte fonctionne sous une tension de 120VAC Enlever le cache interne en d vissant les 4
11. s des codes locaux c Lorsque vous coupez ou perforez un mur ou un plafond prenez garde de ne pas endommager les fils lectriques ou autre installation qui pourrait y tre dissimul s d Les conduits de l installation doivent toujours vacuer l air l ext rieur e Ne jamais utiliser un syst me de contr le de vitesse externe pour contr ler la vitesse du moteur f Cet appareil doit tre reli une mise la terre pour viter tout choc lectrique AVERTISSEMENT POUR R DUIRE LE RISQUE DE FEU UTILISER SEULEMENT DES CONDUITS D AIR METALLIQUES AVERTISSEMENT POUR REDUIRE LE RISQUE DE FEU DE LA CUISINIERE a Ne laissez jamais les appareils de cuisson sans surveillance lorsqu ils sont r gl s a feu vif Les d bordements engendrent de la fum e et des versements graisseux pouvant s enflammer Chauffez l huile lentement feu doux ou moyen b Mettez toujours la hotte en marche lorsque vous cuisinez feu vif ou que vous cuisinez des mets flamb s par exemple cr pes Suzette cerises jubil steak au poivre flamb c Nettoyez r guli rement la roue du moteur de ventilateur Ne laissez pas la graisse s accumuler sur le ventilateur ou les filtres d Utilisez le bon format de casserole Servez vous toujours de casseroles et d ustensiles de cuisson appropri s la dimension de la surface chauffante For your Safety Pour Votre s curit FOLLOWING a SMOTHER FLAMES with a c
12. sonnes seront requises pour le d bo tage et l installation Le moteur de la hotte de cuisine est quip d un interrupteur de protection thermique qui arr tera automatiquement le moteur s il devient surchauff ll red marrera automatiquement une fois refroidi Si le moteur continue s arr ter et se remettre en marche faites v rifier votre hotte Installation preparation Preparation de l installation Content CON ree ne es eee es 4 DIM NSIONS isis dccasctsndswoeresniesttedaveiaxesaniisxodasetenns 4 Prior installation c ccccceceececcececeececeeeeeeeaeees 6 Conducts accessories ceccecceeceeceeeeeeeeeeeeness 7 Necessary tools nine 8 Unpacking the box 8 Box COMI NIE ae ed sn treats 8 Prepare the custom canopy 10 Electrical plugging 9 Install the central unit of the range hood aie eet ar oo Erreur Signet non defini Filters installation 10 Use and Care 10 Dimensions Dimensions Dimensions are in cm inch Dimensions sont en cm inch 61 5 cm 24 2 76 cm 30 The distance between the top of the range and the bottom of the range hood should be at minimum 65cm 24 1 2 and at maximum 75cm 29 1 2 This range hood is designed for 8 feet ceiling height Following this installation manual will allow you to satisfy the requirements of the minimal distance between the range hood bottom and the range s top
13. t Prior to installation you Avant installation should know that the sachez que la hotte range hood must be doit tre au dessus de 65 to 75 cm 25 to la cuisini re de 65 29 above the range 75 cm 25 to 29 2 PK 4002 Rev 2 5 Prior installation Determine the appropriate location of the range hood We recommend that this installation should be installed by a certified electrician Therefore to schedule the installation start by contacting an electrician Electrical Installation An electrical connexion 120V 60Hz should be provided near the range hood s location and should have two wires and a third one for ground This electrical source must be connected to a 15 to 20 amp breaker Conducts installation Plan the air extraction way fora better exhausting efficiency optimize the air circuit by minimizing the total conducts length to outside and the number of direction changes The total length should not exceed 100 This range hood should be connected to a rectangular 10 x3 1 4 conduct Duct conversions in downstream are allowed but could affect the exhausting efficiency of the range hood If the exhausting installation is connected to a natural combustion system it is important to read carefully the instructions of such combustion system provided by the manufacturer Refer to the next table see next page to calculate the total length of the conducts of the exhausting system Do not
14. use non metallic conducts A Warning To avoid any fire risk be sure that the conduct system exhausts the air to outside and not in a non closed area with a ceilling or walls PK 4002 Rev 2 Installation preparation Preparation de l installation Avant l installation D terminer l emplacement appropri de votre hotte de cuisine Nous recommandons que l installation soit faite par un lectricien certifi Ainsi un lectricien doit tre contact pour planifier l installation Installation lectrique Une alimentation lectrique de 120V 60Hz doit tre fournie proximit de l emplacement pr vu et doit tre assur e par deux fils et un troisi me de terre Cette alimentation lectrique doit tre raccord e un disjoncteur 15 ou 20Amp Installation des conduites Planifier le chemin d extraction de l air pour une efficacit d extraction optimiser le circuit de mani re minimiser la longueur totale jusqu l ext rieur et le nombre de changement de direction La conduite ne doit jamais atteindre 100 Cette hotte doit se connecter un conduit rectangulaire 10 x3 1 4 Une conversion en avale de forme ou de diam tre est permise mais risquera daffecter la performance d extraction de la hotte Si l installation est connect e a un syst me de combustion naturelle il sera important de lire les instructions fournies par le manufacturier de ce dernier Se r f rer au tableau des types d
15. vis Monter le collet de fixation du c ble sur le grand trou du cache et introduire le c ble lectrique provenant de la maison travers ce collet A l aide des connecteurs fournis connecter le fil noir du c ble de la maison au fil noir de la hotte le fils blanc du c ble de la maison au fil blanc de la hotte et enfin le fil terre de c ble de la maison au fil vert de la hotte Refermer doucement le cache et le revisser par les 4 vis Fixer le c ble de la maison en serrant les vis du collet Une fois que le c ble maison est connect installer le clapet la sortie d air appropri e de la hotte de cuisine et poser du ruban adh sif sur la ligne de connexion pour plus d tanch it Note v rifier le bon sens de l installation de du clapet de mani re permettre l air de sortir du ventillateur vers l ext rieur et non le contraire Installation steps tapes de l installation Prepare the custom canopy The custom canopy should respect the insert s dimensions to be able to make the installation see dimensions of the insert and should be able to support a charge of 25 Kg Secure the wooden bars see figure below Install the range hood unit between the wooden bars make sure that there is no space between the insert and the bottom of the cabinet Fix the insert main unit by using the 7 provided screws Make sure the insert main unit is well mounted and there is no risk of vibration once it is wor
Download Pdf Manuals
Related Search
Related Contents
Fiberon BRDPRTF CN 20-10PK Use and Care Manual キャリアネットワークから小規模事業所まで多様なニーズをサポート Si 広報たかはし9月号 [PDFファイル/4.88MB] Samsung GT-I5800 3.2" 109g White Consulter le rappel de sécurité Documento PDF - Università degli Studi di Padova LE THÉÂTRE MODE D`EMPLOI Les Die Flatrate Diät – Mit einfachen Tricks systematisch zur Wunschfigur Sharp XE-A402 Quick Guide Copyright © All rights reserved.