Home

Manuel d`utilisation unités d`énergie CPS2

image

Contents

1. Peak to peak ripple and noise lt 250mV lt 250mV lt 250mV Automotive output fuses mounted in 2 x 20A 32V parallel in the BAT pole es F3 F4 Environment Operating temperature 10 C to 45 C 45 C to 50 C with 10 de rating of rated Power C Cooling Natural Draft fan controlled by internal temperature probe 60 C dissipation 5 C Relative humidity Up to 70 95 with no condensation Storage temperature 20 C to 70 C Case Material Case comprises 2 parts aluminium frame and steel front cover Paintwork Mat black and grey epoxy coating Dimensions excluding cable gland length 375 x 242 x 375 x 242 x 395 x 262 x height depth Weight 106mm 3 6Kg 106mm 3 7Kg 116mm 5 6Kg Fixing centre distances 357x 190mm 357x 190mm 377 x 190mm Wall screw 4 5 round screws Protection factor IP21 Board protection Protected with water repellent varnish marine environment Standards CE CEM markings NF EN6100 6 1 NF EN6100 6 2 NF EN6100 6 3 NF 6100 6 4 CE safety markings NF EN60950 NF EN603635 2 29 Electrical protection Against leaking input surges by rupture of VDR voltage dependent resistor Against output polarity reversals by rupture of fuses Against output short circuits and surges Against abnormal overheating by cutting off the charger internal temperature probe 90 C Against output surges UECPS2 12 16 25 40 DEA DOC 22 4 CRISTEC
2. 0 23 3 1 OPERATING PRINCIPLE A nn oo 23 3 2 SWITCH SETTINGS ADJUSTMENTS anan aana en nan anna na nana anan aana nane anana 23 2 2210 ADVCSCHIUPUON AP aana aan 23 3 2 2 Switch settings and positions 23 3 2 3 Settings for each type 24 3 24 ON 24 5229 BOA CUP Ve isian dette ENE A E RE TANG LAN E Kai 25 A annee see 26 INSTALLATION 26 4 1 SITING THE SHORE POWER UNIT ss a a e a es 27 4 2 WIRIN EG n aa E an aa DA AA GA D tues AN dd 27 4 2 1 Moi dani ba a ka Nah an paga aaa does 27 4 2 2 Cable from the public AC power supply network or 27 423 BONEY san a cu ana Sees a aa panga a aan naa isis a aa ye aa padhaa pa aa a aana eS 26 4 2 4 Cable linking the earth to the installation siennes 28 4 2 5 Precautions regarding electromagnetic disturbance generated by the appliance ss 28 4 2 0 O2 110 pn Ara 29 AUNAR 30 5 1 ELECTRICITY NETWORK coi ias 30 5 2 SHORE POWER UNIT COMPATIBILITY
3. 3 OPERATION SETTINGS ADJUSTMENTS INDICATORS 3 1 OPERATING PRINCIPLE The shore power units allow to get in a single cabinet the 230VAC on board protection and a battery charger The shore power units housings meet the European on going rules Compact and lightweight they provide practical entry for the cabling that reduces mounting time The user protection is insured by a 16A 30mA differential circuit breaker The on board utilisation outputs are protected by 2 3 or 4 10A DPN thermo magnetic circuit breakers The design of the shore power units in the CPS2 range is based on a high frequency split converter that transforms the AC signal into regulated and filtered DC current They can operate as battery chargers on a DC power supply Once the type of battery and type of charge has been selected operation of the shore power unit is entirely automatic It can remain connected to the batteries and does not need to be disconnected when starting up an engine marine application because it is equipped with rectifier diodes The appliance s output voltage is sufficient to recharge 1 2 or separate 3 batteries integrated charge distributors separation of batteries All models feature an output suitable for recharging an engine battery BAT D output marine application The charger s maximum output is the rated current distributed to each output according to the batteries usage needs Each output can deliver the rated current
4. ACRISTEC l nergie embarqu e Manuel d utilisation unit s d nergie CPS2 User manual CPS2 shore power units UECPS2 12 16 2D UECPS2 12 16 3D UECPS2 12 16 4D UECPS2 12 25 2D UECPS2 12 25 3D UECPS2 12 25 4D UECPS2 12 40 3D UECPS2 12 40 4D S A S CRISTEC 47 rue Pierre Mend s France 29000 QUIMPER FRANCE T l 33 0 2 98 53 80 82 Fax 33 0 2 98 55 64 94 e mail info cristec fr http www cristec fr ANCRISTEC UECPS2 12 16 25 40 DEA DOC IACRISTEC Sommaire Manuel d utilisation en Francais Contents Operating Manual in English Annexe UECPS2 12 16 25 40 DEA DOC 3 4 CRISTEC 1 8 SOMMAIRE PRECAUTIONS GARANTIE se isvssscssssessievscsnsccesssoudesseceesssvesevessvecoossevesevasevecesussueeesoesviseecentssucveceveevesseseesscavesousesveseveresusevesdeuceses 6 1 1 PRECAUTIONS ian sea DEN a naga a a iia irse 6 1 2 GARANTIE odiada ds 7 SPECIFICATIONS TECHNIQUES ssssssiscsesassesestsesesesonssenacetesesseasssocesssscesentenscseeosesensedsuiesessssdecesoessssensessnss 8 2 1 UEGPS2 12V 16A 12 V 25 A 12 VIDA o 8 FONCTIONNEMENT CONFIGURATION REGLAGES INDICATEURS csssscsssscccsssscceesscccesseccesssseceessseeceses 9 3 1 PRINCIPE DE FONCTIONNEMENT ini 9 3 2 CONFIGURATION DES SWITCHS REGLAGES
5. n ral peut galement tre r alis en nos usines 6 3 REPARATION DES EQUIPEMENTS D connecter l unit d nergie du r seau alternatif et des batteries pour toute op ration de r paration En cas de rupture des fusibles respecter le calibre et le type de fusible pr conis dans la pr sente notice Pour toute autre intervention de r paration contacter un revendeur ou la soci t CRISTEC 7 DISPOSITIONS RELATIVES A LA SECURITE 7 1 REFERENCES NORMATIVES Mat riel de classe I selon la norme NF EN 60950 Les prescriptions d installation sont contenues dans la norme NFC 15 100 et la norme sp cifique aux navires de plaisance syst mes lectriques Installation de distribution de courant alternatif de r f rence 15013297 7 2 PRECAUTIONS RELATIVES A LA SECURITE DES PERSONNES L installation doit tre r alis e par un lectricien ou un installateur professionnel Le r seau d entr e alternatif doit tre coup avant toute intervention sur l quipement 73 PRECAUTIONS RELATIVES LA PROTECTION CONTRE LE FEU ET LES EXPLOSIONS Utiliser les fusibles d finis dans la pr sente notice A proximit des batteries ventiler le local ne pas fumer ne pas utiliser de flamme vive UECPS2 12 16 25 40 DEA DOC 17 ANCRISTEC 8 CERTIFICATION DE CONFORMITE CE DECLARATION DE CONFORMITE aux dispositions de la directive 89 336 CEE Compatibilit Electromagn tique et aux dispositions de la directive 73
6. n rale l entr e par disjoncteur 16A bipolaire diff rentiel 30 mA e D parts alternatifs Protection par 2 3 ou 4 selon mod le disjoncteurs magn to thermiques DPN 10 Groupes lectrog nes L unit d nergie CRISTEC est con ue pour fonctionner sur groupe lectrog ne Dans certains cas les groupes lectrog nes peuvent g n rer des surtensions importantes Avant raccordement de l unit d nergie v rifier la compatibilit des caract ristiques du groupe et celles de l unit d nergie puissance tension surtension fr quence courant 5 2 COMPATIBILITE ET CONFIGURATION DE L UNITE D ENERGIE EN FONCTION DES BATTERIES V rifier imp rativement la compatibilit de tension de courant et la configuration en fonction du type de batteries raccord avant toute mise sous tension V rification de la tension de charge Avant raccordement des batteries a l unit d nergie il est imp ratif de v rifier la polarit des accumulateurs V rifier galement la tension des batteries l aide d un voltm tre talonn Une valeur trop basse de tension sur certains types d accumulateurs peut indiquer une d gradation irr versible de ceux ci et donc une impossibilit de recharge 53 ARRET MARCHE DE L UNITE D ENERGIE L unit d nergie CPS2 est en fonctionnement d s lors qu elle est sous tension cable de r seau d entr e connect et aliment L unit d nergie
7. t des batteries dans un local sec ventil de toute p n tration d humidit et de toute poussi re Sa circulation d air doit tre libre Les recommandations cit es dans le paragraphe 1 doivent tre respect es est imp ratif de positionner Punit d nergie en position verticale arriv e des c bles par le bas La fixation de l unit d nergie se fait par 4 vis MS t te ronde diam tre de la t te de vis inf rieur lt a 10mm afin d assurer l ouverture du capot Entraxe de fixation voir plan correspondant en annexe 4 2 CABLAGE 4 2 1 Arriv e des c bles L arriv e du c ble secteur se fait au travers d un presse toupe L arriv e des c bles batteries et ou utilisation se fait au travers de passe c bles L arriv e des c bles options voir paragraphe 4 2 6 options se fait au travers de deux encoches situ es au dessus des passe c bles Pour connecter et d connecter un c ble l alimentation de l unit d nergie doit imp rativement tre coup e et les batteries isol es lectriquement de l unit d nergie Les r f rences des fournitures compl mentaires n cessaires au bon fonctionnement de l appareil sont d finies dans les paragraphes ci dessous tout non respect de ces dispositions entra ne une annulation syst matique de la garantie 4 2 2 C ble de liaison r seau alternatif public ou groupe lectrog ne Le c ble d alimentation doit se connecter
8. AND SETTINGS ACCORDING TO BATTERY 30 5 3 TURNING THE SHORE POWER UNIT ON AND OFF nn rennes sense esse 30 EQUIPMENT MAINTENANCE AND 31 6 1 OVERVIEW sang O a aana a aa NABA eaaa a aa aana 31 6 2 EQUIPMENT MAINTENANCE pa t a AD aa Na an a kaa an Akang Dai KNA 31 6 3 EQUIPMENT REPA cuando doo kan aga S rere atte 31 SAFETY PRECAUTIONS 250 soreo roS e taron ro ess Eases 31 74 REFERENCE STANDARDS A 31 7 2 PERSONAL SAFETY PR CAUTIONS is eaaa asas ong aaa aba san a aka SS SASS kee ERIN GENENG IN einen Rien sets 31 7 3 PRECAUTIONS REGARDING THE RISK OF FIRE AND EXPLOSIONS inserer 31 CE CERTIFICATION OF 00 32 UECPS2 12 16 25 40 DEA DOC 5 4 CRISTEC 1 PRECAUTIONS GARANTIE La fourniture CRISTEC comprend les l ments suivants gt 1 bo tier m tallique contenant la fonction lectronique chargeur de batteries et les disjoncteurs de protection 230V gt Le pr sent manuel d utilisation Le pr sent document s applique aux unit s d nergie de la gamme CPS2 CRISTEC list es en couverture Ce manuel est destin aux utilisateurs installateurs et personnels d entretien de l quipement Ceux ci doivent imp rativement prendre connaissance
9. CPS2 est l arr t d s qu elle n est plus sous tension c ble de r seau d entr e d connect ou disjoncteur de l installation sur la position OFF ATTENTION si l option Arr t Marche du chargeur est utilis e le chargeur peut tre l arr t mais l unit d nergie n anmoins sous tension tension dangereuse UECPS2 12 16 25 40 DEA DOC 16 4 CRISTEC 6 DISPOSITIONS RELATIVES A LA MAINTENANCE ET A LA REPARATION DE L EQUIPEMENT 6 1 GENERALITES Ce paragraphe traite des dispositions relatives la maintenance et aux r parations de l quipement Le bon fonctionnement et la dur e de vie du produit sont conditionn s par le strict respect des recommandations contenues ci apr s 6 2 MAINTENANCE DES EQUIPEMENTS D connecter l unit d nergie du r seau alternatif pour toutes les op rations de maintenance Si les appareils sont plac s dans une ambiance poussi reuse les nettoyer p riodiquement par aspiration les d p ts de poussi re pouvant alt rer l vacuation de la chaleur V rifier l tat de charge des batteries tous les 3 mois Une v rification annuelle du serrage des crous et vis est n cessaire pour garantir le bon fonctionnement de l appareil particuli rement en milieu perturb vibrations chocs carts de temp rature importants etc Une visite technique compl te par un intervenant recommand CRISTEC est conseill tous les 5 ans Ce contr le technique g
10. Courant nominal total 7 Puissance nominale 16A 228W 25A 356W 40A 570W Courbe de charge Choix du type de charge par commutateur interne IU ou 1000 Boost Absorption Floating configuration usine Type de batteries Voir tableau de configuration des switchs Tension de sortie r gul e et filtr e Voir tableau de configuration des switchs Les chargeurs peuvent fonctionner en alimentation courant continu Tol rance de r gulation avant r partiteur lt 2 et fusibles Ondulation et bruit cr te a cr te lt 250mV lt 250mV lt 250mV Fusibles automotive de sortie mont s en 2 x 20A 32V parall le dans le p le BAT RE F3 F4 Environnement Temp rature de fonctionnement 10 C 45 C 45 C 50 C avec d rating de 10 de Pnom C Refroidissement Dissipation Ventilateur souffleur pilot par sonde thermique interne naturelle 60 C 5 C Humidit relative Jusqu a 70 95 sans condensation Temp rature de stockage 20 C 70 C Coffret Mat riau Coffret compos de 2 pi ces ch ssis en aluminium et capot en acier Peinture Rev tement poxy noir mat et gris Dimensions hors presse toupe longueur 375 x 242 x 375 x 242 x 395 x 262 x hauteur profondeur Poids 106mm 3 6Kg 106mm 3 7Kg 116mm 5 6Kg Entraxes de fixation 357x 190mm 357x 190mm 377 x 190mm Vis de fixation murale 4 vis 5 t te ronde I
11. Not all the outputs have to be connected However if only one output is used we recommend interconnecting outputs BAT1 BAT2 and BAT D to one another optional 32 SWITCH SETTINGS ADJUSTMENTS INDICATORS 3 2 1 Description The CPS2 shore power units are equipped with switches allowing you to set up the charger according to the type of batteries and the application CPS2 chargers feature the Boost function for faster recharging This function is controlled by a timeout 4 hours 10 minutes and is automatically inhibited when the battery is fully charged stoppage of the boost for I batteries lt 15 of I rated charger The Boost function can also be disabled by means of a switch 3 2 2 Switch settings and positions mmm SWI Boost selector SW2 to SWS Battery type selector UECPS2 12 16 25 40 DEA DOC 23 4 CRISTEC 3 2 3 Settings for each type of battery Type of battery Switch positions CPS2 12V Voltage Voltage Swi Phase Phase Boost Boost Floating SWS 8 4 SW3 SW2 TYPE 1 BAT Calcium Lead Tin e g OFF OFF OFF ON ON 15 1V 14 4V Delphi Delco Freedom TYPE 2 BAT Lead Sealed TYPE 3 BAT Gelled Lead or Calcium Lead TYPE 4 BAT Open Lead with maintenance ON OFF OFF OFF ON 13 7V 13V free electrolyte WINTERING for TYPE 1 BAT TYPE 2 BAT TYPE 3 BAT WINTERING For TYPE 4 BAT OFF OFF ON OFF ON 14 3V 13 6V OFF ON
12. OFF OFF ON 14 1V 13 4V OFF ON OFF OFF ON 14 1V 13 4V ON OFF OFF OFF ON 13 7V 13V Voltage on BAT 1 BAT 2 with 10 of rated current and a tolerance of 1 Voltage on BAT D BAT 1 or BAT 2 approx 0 4V 3 2 4 Settings The shore power unit s factory settings are TYPE 2 BAT Sealed Lead see table above BOOST in ON position The installer should set the switches excluding input and off load output voltage and possibly adjust the output voltage using potentiometer RV1 use the appropriate tool to turn the screw of the potentiometer depending on the type of battery contact the battery manufacturer if necessary intended usage the cross section and length of the output cables whether or not the boost function is required For special batteries call in a professional installer who will make the specific settings in accordance with the accumulator manufacturer s specifications and according to the specifics of the installation Cristec disclaims any liability in case of damage to batteries or ineffective recharging UECPS2 12 16 25 40 DEA DOC 24 4 CRISTEC 3 2 5 Load curve Boost in ON position With this setting the CPS2 shore power unit produces a 3 state load curve IUoU Boost Absorption Floating Flat battery Battery only slightly flat U out 1 U Boost Abs
13. REPARATION DE L EQUIPEMENT 17 6 1 GENERALE tate a UP 17 6 2 MAINTENANCE DES EQUIPEMENTS ccccecsessssssecececeeuaeseeececseuaesecececseseaueseeececeeseaasaesececeeseaueaeeeeceseceseaaeseesceesessaeeeeeeeeeersaaes 17 6 3 REPARATION DES EQUIPEMENTS cccceceeseseceeececsesssaececececeesensesececeeecessuaaeceesccesessaaesecececeeseaueceescecseeaueaeceeeceesessaeeeeeeeceeseaaees 17 DISPOSITIONS RELATIVES LA 17 74 REFERENCES NORMATIVES orisa ean E aa a a es a 17 7 2 PRECAUTIONS RELATIVES A LA SECURITE DES PERSONNES ssssssssecessesesseseeececsesesseeesecececseseaeeeeeeseseeuaeseesceesesseaueeeeceeeereaaees 17 7 3 PRECAUTIONS RELATIVES A LA PROTECTION CONTRE LE FEU ET LES EXPLOSIONS eee cesser 17 CERTIFICATION DE CONFORMITE 18 UECPS2 12 16 25 40 DEA DOC 4 4 CRISTEC 1 8 PRECAUTIONS WARRANTY Seuss Voes evos TEESE 20 1 1 PRECAUTIONS Tan ac a nga E 20 1 2 WARRANTY oo ao oa 21 TECHNICAL SPECIFICATIONS sisissccsssccesssisssascsscscacsssstisssnedssasassscsnssosssessonssoctssesdesnsosesccsceacseuasac cssbcousdeuess suis sasaccsisesssisesd senses 22 2 1 5212 16 1217254 I2V 40A A a ian Gan 22 OPERATION SETTINGS ADJUSTMENTS
14. d usine BAT TYPE 2 Plomb tanche voir tableau pr c dent BOOST en position ON L installateur doit configurer hors tension entr e et sortie vide les switchs et ventuellement ajuster la tension de sortie via le potentiom tre RV1 utiliser l outil ad quat pour tourner la vis du potentiom tre fonction du type de batterie contacter le constructeur de batteries si n cessaire du type d utilisation dela section et longueur des cables de sortie dela n cessit ou non de la fonction boost En cas de batteries sp ciales se r f rer a un installateur professionnel qui effectuera les r glages particuliers en accord avec les sp cifications du constructeur d accumulateurs et en tenant compte des particularit s de l installation CRISTEC d cline toute responsabilit en cas de d t rioration des batteries ou de mauvaise recharge UECPS2 12 16 25 40 DEA DOC 10 ACRISTEC 3 2 5 Courbe de charge Boost en position ON Dans cette configuration l unit d nergie CPS2 d livre une courbe de charge 3 tats IUoU Boost Absorption Floating Batterie d charg e Batterie faiblement d charg e U out U out charger charger Boost Absorption Floating Boost Absorption Floating 4 4 U boost U boost U floating U floating 0 4Hrs 0 lt 4 Hrs t I out 1 charger charger Boost Absorption Floating Boost Absorption Floating nom 15 1 nom 4
15. directive 89 336 CEE and those of directive73 23 CEE The harmonized standards are as follow NF EN61000 6 1 Electromagnetic compatibility EMC Part 6 1 generic standards Immunity for residential commercial and light industrial environments NF EN61000 6 2 Electromagnetic compatibility EMC Part 6 2 generic standards Immunity for industrial environments NF EN61000 6 3 Electromagnetic compatibility EMC Part 6 3 generic standards Emission standard for residential commercial and light industrial environments NF EN61000 6 4 Electromagnetic compatibility EMC Part 6 4 generic standards Emission standard for industrial environments NF EN 60950 1 Information technology equipment Safety Part I general requirements Place date and signatures Quimper 08 06 2007 Name and position of the signatories Moulay TAOUFIK Product Manager Didier MARGERAND Chairman CE marking awarded in 2007 UECPS2 12 16 25 40 DEA DOC 32 ANCRISTEC UECPS2 12 16 25 40 DEA DOC 33 ANCRISTEC UECPS2 12 16 25 40 DEA DOC Annexe 34 WEL Z8vV80 N 00 0 10 Sumos 1 8 Jo osvo 1281200 uonemsyuos 5 9 X19 110q pesn jspe Jo 4 14015 2919105 no Lyg 1233D0q Lv
16. du pr sent document avant toute intervention sur l unit d nergie Ce manuel doit tre conserv avec soin et consult avant toute intervention car il contient toutes les informations relatives l utilisation de l appareil Ce document est la propri t de CRISTEC toutes les informations contenues dans ce document s appliquent au produit qui l accompagne La soci t se r serve le droit d en modifier les sp cifications sans pr avis 11 PRECAUTIONS Dispositions vis vis des chauffements de l appareil L quipement est con u pour tre mont sur une paroi verticale selon les indications fournies dans ce manuel Il est imp ratif de conserver une zone de 150mm autour de l unit d nergie L installateur prendra les dispositions n cessaires pour que la temp rature d air l entr e soit inf rieure 40 C dans les conditions extr mes de fonctionnement Les dispositions n cessaires seront galement prises pour permettre un d gagement de l air chaud de chaque c t de l unit d nergie L unit d nergie ne doit pas tre install e proximit d une source de chaleur Elle doit tre install e dans une zone a r e Les arriv es et sorties d air de l unit d nergie ne doivent pas tre obstru es Dispositions vis vis des poussi res du ruissellement et chutes d eau L emplacement de l unit d nergie doit tre choisi pour viter toute p n tration d humidit de liquide d
17. free room Air circulation should be unhindered The recommendations specified in paragraph 1 must be adhered to It is imperative that the shore power unit is placed vertically cable lead in at the bottom The shore power unit is fixed using 4 round 5 screws screw head diameter under 10mm so as not to hamper the opening of the hood Fixing centre distance see corresponding drawing in the appendix 4 2 WIRING 4 2 1 Cable lead in The mains cable lead in is routed through a cable gland The battery cable lead in is routed through cable bushings The options cable lead in see paragraph 4 2 5 options is routed through two slots located over the cable bushings When connecting or disconnecting a cable the shore power unit s power supply must be off and the batteries electrically insulated from the shore power unit The references for additional supplies required for the appliance to operate efficiently are provided in the following paragraphs failure to comply with these provisions renders the warranty null and void 4 2 2 Cable from the public AC power supply network or generator The power cable must be connected to screw terminal board K1 PE ACN and ACL terminals PE Earth ACN Neutral ACL Phase Depending on line lengths the cross section of AC power cables must be at least equal to or greater than the values provided in the table below Minimum cross section and type CPS2 12 16 3 x 1 5mm HO7 VK CPS2
18. lectrique ou lectronique sur l appareil 3 Toute mauvaise utilisation 4 Toute trace d humidit 5 Non respect des tol rances d alimentation 6 Toute erreur dans les connexions 7 Toute chute ou choc lors du transport de l installation ou de l utilisation 8 Toute intervention de personnes non autoris es par CRISTEC 9 Toute connexion d interfaces non fournies par CRISTEC 10 Les frais d emballage et de port 11 Les dommages apparents ou cach s occasionn s par les transports et ou manutentions tout recours doit tre adress au transporteur Notre garantie ne peut en aucun cas donner lieu a une indemnit CRISTEC ne peut tre tenu pour responsable des dommages dus une mauvaise utilisation de l unit d nergie UECPS2 12 16 25 40 DEA DOC 7 ACRISTEC 2 SPECIFICATIONS TECHNIQUES 21 UECPS2 12V 16A 12V 25A 12 40 Modele UECPS2 12 16 UECPS2 12 25 UECPS2 12 40 Entr e Tension 230VCA monophas 15 Fr quence De 47 63Hz Intensit de consommation 230VCA 14 2 3 2A Facteur de puissance 0 9 aux conditions nominales Rendement gt 80 aux conditions nominales Fusibles d entr e F1 F2 Sortie Nombre de sorties 2 6 3A 250V R fDEL MICRO 2 x 10A 250V FUSE 00346623MST 6 3x 32 3 sorties s par es BAT D BAT 1 et BAT 2 r partiteur int gr Chaque sortie peut tre utilis e seule et d biter le courant total
19. sur le bornier vis K1 bornes PE ACN et ACL PE Terre ACN Neutre ACL Phase Selon les longueurs de ligne les cables de liaison r seau alternatif devront tre obligatoirement de section sup rieure ou gale aux valeurs indiqu es dans le tableau ci dessous Section minimale types 52 12 16 52 12 25 CPS2 12 40 3 x 1 5 mm HO7 VK Utiliser imp rativement des embouts collerette isolante en corr lation avec les normes de l installation pour le raccordement de l entr e alternative r seau 3 x 1 5 mm HO7 VK Le conducteur PE commun ment appel terre fil vert jaune de la source alternative doit imp rativement tre raccord l unit d nergie sur la borne pr vue cet effet et avant toute autre borne Se reporter au plan correspondant en annexe UECPS2 12 16 25 40 DEA DOC 13 4 CRISTEC 4 2 3 C ble de liaison batterie Le chargeur de l unit d nergie CPS2 est quip de 4 bornes de sortie K4 BAT moins parc batteries 5 BAT D plus batterie de d marrage pour application de type marine K6 BAT 1 plus batterie parc 1 K7 BAT 2 plus batterie parc 2 Jusqu a 3 m tres les c bles de liaison batteries doivent tre obligatoirement de section sup rieure ou gale aux valeurs indiqu es dans le tableau ci dessous Section des c bles de Diam tre du trou Mod le er batteries mM 5 la cosse CPS2 12 16 16 Le type de c
20. 0 02 VSZ V9 ACL ALINN 1 8 4egr 01 8 19 1vg ZHOS 104100 0 51110 ZH0S JVAOEZ A ddns 314405 NOILY BAT TYPE4 Mo Sws BAT TYPE3 Mr SW BAT TYPE 2 Me sw3 BAT TYPE 1 Sw2 tat CF s a 5 a lt 3 x E 3 5 5 a kl a n 3 5 E 2 a al 2 4 WARNING FOR CON 2 K1 K8 K11 K2 K9 K3 K10 RV1 K4 Carte Board 12V 16A 12V 25A 08 06 2007 N 08482 14 ACRISTEC Terre Earth ACN Neutre Neutral ACL Phase Phase Batt 5 Batt D K6 Batt 1 K7 Batt 2 Sorties batteries Battery outputs 2 amp Ne pas connecter d ordinateur sur ces bornes Do not connect a computer to these terminals K2 Sonde temp rature Temperature probe K3 Afficheur num rique d port Off centre digital display unit K8 Arr t Marche distance Remote On Off K9 Arr t Marche ventilateur distance Remote fan On off K10 Voltm tre Amp rem tre analogiques d port s Off centre analogue Voltmeter Ammeter K11 Boost distance Remote Boost R glage de la tension de sortie Adjusting output voltage SWI SW2 SW3 SW4 SWS Switchs de c
21. 0062 9JUe Jj d AV 17 2605 NOIX INNO vo est 07 0 WOH ACL ZH0S JVADEZ iddns 128 q 188 ziva Live diva 104100 NOILVSIULN JVA0EZ Alddns 1 15 14 13 12 K7 19 18 17 K6 K5 Sd 15008 ING 2 ING JdAL LYS ISNA 40 ONY JAYS AINO 39V1d38 ddA 1 1 va 3414 ISNIVOY NOILOJLOYA GANNILNOD X04 ONINAYM K8 RV1 K11 K2 K10 K4 08 06 2007 8484 14 K1 Carte Board 12V 40A ACRISTEC Terre Earth ACN Neutre Neutral ACL Phase Phase Batt 5 Batt D K6 Batt 1 K7 Batt 2 Sorties batteries Battery outputs 2 amp Ne pas connecter d ordinateur sur ces bornes Do not connect a computer to these terminals K2 Sonde temp rature Temperature probe K3 Afficheur num rique d port Off centre digital display unit K8 Arr t Marche distance Remote On Off K9 Arr t Marche ventilateur distance Remote fan On off K10 Voltm tre Amp rem tre analogiques d port s Off centre analogue Voltmeter Ammeter K11 Boost distance Remote Boost R glage de la tension de sortie Adjusting output voltage SWI
22. 12 25 CPS2 12 40 3 x 1 5mm HO7 VK Always use cable markers with insulating collars in accordance with installation standards governing AC network input connections The PE conductor commonly called earth the green and yellow wire of the AC source must be connected to the shore power unit on the terminal provided for the purpose and this must be done before connecting any other terminals Please refer to the relevant diagram in the appendix UECPS2 12 16 25 40 DEA DOC 27 4 CRISTEC 4 2 3 Battery cable The CPS2 charger is equipped with 4 output terminals K4 BAT minus set of batteries 5 BAT D plus start up battery for marine type applications K6 BAT 1 plus battery set 1 K7 BAT 2 plus battery set 2 Up to 3 metres the cross section of the battery cables should be at least equal to or greater than the values provided in the table below wa Te section terminal hole CPS2 12 16 6 mm 5mm The installer should choose the type of cable H07 VK MX according to the type of application and the applicable standards The cable bushings or glands must remain on the lower side of the case to avoid the linking cables being damaged on the metal walls of the case and to guarantee insulation between the active conductors and the electrical exposed conductive part See relevant drawing in the appendix 4 2 4 Cable linking the earth to the installation The shore power unit s case should b
23. 15961 nom bp 0 4 Hrs t 0 lt 4 Hrs t Phase Boost d marre automatiquement la mise sous tension de l unit d nergie si la batterie est d charg e Le courant est alors maximum Phase Absorption commence d s que la tension a atteint la valeur maximale du Boost Le courant commence a d croitre Ces deux phases cumul es durent au maximum 4 heures Si le courant atteint une valeur inf rieure a 15 du courant nominal la phase floating s enclenche automatiquement La dur e et le courant d pendent de l tat de charge de la batterie Phase Floating d bute au bout de 4 heures ou si le courant d livr a atteint 15 du courant nominal de l unit d nergie La tension bascule a la valeur Floating et le courant continu a d croitre UECPS2 12 16 25 40 DEA DOC 11 4 CRISTEC Boost en position OFF Dans cette configuration l unit d nergie CPS2 d livre une courbe de charge de type mono palier IU Elle g n re une tension constante et fournit le courant n cessaire la ou les batteries Le temps de recharge d pend de l tat de la batterie et est plus long que dans la configuration boost en position ON U out charger U floating t I out charger I nom 3 2 6 Indicateurs INDICATEUR ETAT SIGNIFICATION Vert ON Allum Chargeur sous tension Eteint Absence ou d gradation du r seau alternatif ou Rupture fus
24. 23 CEE Basse Tension Constructeur CRISTEC Adresse 47 Avenue Pierre Mend s France 29000 Quimper FRANCE D clare que les unit s d nergies CPS2 12V 16A 12V 25A 12V 40A Sont conformes aux dispositions de la directive 89 336 CEE et aux dispositions de la directive73 23 CEE Les normes harmonis es appliqu es sont les suivantes NF EN61000 6 1 Compatibilit lectromagn tique CEM Partie 6 1 normes g n riques Immunit pour les environnements r sidentiels commerciaux et de l industrie l gere NF EN61000 6 2 Compatibilit lectromagn tique CEM Partie 6 2 normes g n riques Immunit pour les environnements industriels NF EN61000 6 3 Compatibilit lectromagn tique CEM Partie 6 3 normes g n riques Norme sur l mission pour les environnements r sidentiels commerciaux et de l industrie l gere NF EN61000 6 4 Compatibilit lectromagn tique CEM Partie 6 4 normes g n riques Norme sur l mission pour les environnements industriels NF 60950 1 Mat riels de traitement de l information S curit Partie 1 prescriptions g n rales Lieu date et signatures Quimper 08 06 2007 Nom et titre des signataires Moulay TAOUFIK Chef Produits Didier MARGERAND Pr sident Ann e d approbation du marquage CE 2007 UECPS2 12 16 25 40 DEA DOC 18 ANCRISTEC UECPS2 12 16 25 40 DEA DOC 19 ACRISTEC 1 PRECAUTIONS WARRANTY The Cristec includ
25. 3 2 6 Indicators INDICATOR STATE MEANING Green ON On Charger is ON Off No or poor quality AC current or Input fuse blown or Internal charger malfunction or Cut off of the main circuit breaker Yellow On SW1 Switch Boost in OFF position Boost Absorpt or SW1 switch Boost in ON position and Boost Absorption phase completed ion Flashing SW1 Switch Boost in ON position and charger in the Boost Absorption phase Off Internal charger malfunction or Output fuse blown Yellow On Charger current lt 15 of rated current Floating phase Floating Off Charger current gt 15 rated current These indicators are visible from the front of the appliance through the light guides thereby allowing operation of the appliance to be monitored 4 INSTALLATION This paragraph deals with installation related arrangements Installation and initial commissioning should be carried out by an electrician or professional installer in accordance with the standards currently in force for pleasure boats the applicable international standard is 15013297 The installer should familiarize himself with this operating manual and inform users of the instructions for use and the safety warnings set out in paragraph 7 UECPS2 12 16 25 40 DEA DOC 26 4 CRISTEC 4 1 SITING THE SHORE POWER UNIT The CPS2 shore power unit should be installed as near as possible to the batteries in a dry well ventilated and fully damp proof and dust
26. INDICATEURS 9 genea en aaa lek Dh ea Ae 9 3 2 2 Disposition des switchs de configuration wanan an Nana nn 9 3 2 3 Configuration en fonction du type de 10 2237 cet E RN des aa aaa anan 10 3 25 COULD de CHANGE oc anna aan s baan angan na nga aa ga tsa ang aba Laga e 11 3260 o 12 INSTALLATIONS SESS sae nasa EERE E e 12 4 1 MONTAGE DE UNITED ENERGIE ci 13 4 2 ro oo 13 BDA AVEC BS cabl Ote a ARS ee 13 4 2 2 Cable de liaison r seau alternatif public ou groupe lectrog ne ss 13 4 2 3 Cable de liaison batterie 14 4 2 4 C ble de liaison la masse de 1 sess 14 4 2 5 Dispositions vis vis des perturbations lectromagn tiques g n r es par l appareil ss 14 ALO cates nag ah Ng 15 MISE EN SERVICE NN 16 5 1 RESEAUD ENTREE Sos KAKA 16 5 2 COMPATIBILITE ET CONFIGURATION DE UNITE D ENERGIE EN FONCTION DES BATTERIES 16 5 3 ARRET MARCHE DE L UNITE D ENERGIE aies erse ECE EE Sree Sebe Soe 16 DISPOSITIONS RELATIVES LA MAINTENANCE ET A LA
27. PS2 CPS2 12 40 AMP 12V 40A CPS2 Remote LEDs option reference LED DEP CPS2 A 5 metre cable to connect on KLD1 KLD2 KLD3 UECPS2 12 16 25 40 DEA DOC 29 4 CRISTEC 5 COMMISSIONING This paragraph lists all the tasks required to bring the equipment into service These instructions should be followed to the letter before first turning on the appliance 5 1 ELECTRICITY NETWORK All CPS2 shore power units can operate automatically and equally on single phase networks from 230VAC 15 and from 47 to 63Hz Characteristics distribution AC e General input protection by a 30mA 16A differential circuit breaker e AC outputs protected by 2 3 or 4 depending on the model thermo magnetic circuit breaker DPN 10A Generators The Cristec shore power unit is designed to operate on a generator In certain cases generators can produce high surges Before connecting the shore power unit check its compatibility with the generator s characteristics power voltage surges frequency current etc 5 2 SHORE POWER UNIT COMPATIBILITY AND SETTINGS ACCORDING TO BATTERY TYPE Before switching on be sure to check the compatibility of voltage current and settings according to the type of batteries connected Checking the load voltage Before connecting the batteries to the shore power unit you must check the polarity of the accumulators Also check the voltage of the batteries with the aid of a calibrated voltmeter A low vo
28. S parer les cables de puissance et les c bles de contr le minimum 200mm Les c bles doivent assurer uniquement l alimentation de l appareil Une d rivation ou un pontage afin d alimenter un autre appareil sont prohiber Ceci est un conseil d installation et non une obligation L lectricien installateur d cide compte tenu de l environnement CEM de l emploi de c ble blind ou non UECPS2 12 16 25 40 DEA DOC 14 ANCRISTEC 4 2 6 Options Les options ne font pas partie de la fourniture de base des unit s d nergies CPS2 elles sont disponibles aupr s de votre revendeur Seules les options commercialis es par CRISTEC peuvent tre mont es avec les chargeurs Les options disponibles pour la gamme CPS2 sont Commande Arr t Marche du chargeur a distance r f rence A M CPS2 C ble de 5 m tres commutateur Arr t Marche connecter sur connecteur K8 voir plan en annexe Commande Boost a distance r f rence BAD CPS2 Cable de 5 m tres commutateur Boost ON Boost OFF a connecter sur K11 voir plan en annexe Sonde de temp rature r f rence STP CPS2 Permet la compensation de la tension de charge en fonction de la temp rature Chargeur 12V 18mV C Cable de 5 m tres sonde connecter sur K2 voir plan annexe Afficheur num rique r f rence SEEL009104 Permet d afficher l tat du chargeur ON OFF le courant chargeur la tension de chacune des 3 sorties et le pourcentage de cha
29. SW2 SW3 SW4 SWS Switchs de configuration Settings switches F1 F2 Fusibles d entr e Input fuses F3 F4 F5 Fusible de sortie Output fuse LD1 LD2 1 03 Leds d tat State LEDs KLD1 KLD2 KLD3 Option LEDs ON Boost Absorption Floating deportees ON Boost Absorption Floating stand alone LED option UECPS2 12 16 25 40 DEA DOC 43 UECPS2 12 16 25 40 DEA DOC 44
30. ble H07 VK MX devra tre d fini par l installateur en fonction du type d application et des normes applicables Conserver imp rativement les passe c bles ou les presse toupe sur la face inf rieure du coffret pour viter toute d gradation des c bles de liaison sur les parois m talliques du coffret et garantir une isolation entre les conducteurs actifs et la masse lectrique Voir plan correspondant en annexe 4 2 4 C ble de liaison la masse de Pinstallation En fonction des normes en vigueur l application concern e le coffret de l unit d nergie devra tre reli au plan de masse l installation Pour cela connecter le c ble de liaison a la masse de l installation la vis de masse situ e l int rieur de l unit d nergie voir plan en annexe Le cable utilis doit avoir une section minimale de 2 5mm et tre de type HO7 VK et tre muni d une cosse appropri e 4 2 5 Dispositions vis vis des perturbations lectromagn tiques g n r es par l appareil Utiliser du c ble blind pour toutes les connexions Le blindage doit tre raccord c t metteur et c t r cepteur la masse R duire au maximum la longueur des c bles et les connexions des blindages Faire passer les c bles au plus pr s des masses les c bles volants ou les boucles sont viter plaquer les c bles contre les masses S parer les c bles d alimentation et d utilisation
31. e connected to the installation s earthing system in accordance with current standards governing the relevant application To that effect connect the installation to earth cable to the earthing screw located inside the shore power unit see drawing in appendix This cable s cross section should be at least 2 5mm type HO7 VK and equipped with an appropriate terminal 4 2 5 Precautions regarding electromagnetic disturbance generated by the appliance Use shielded cables for all the connections The shielding should be earthed at both the transmitting and the receiving ends Keep cable length and shielding connections down to a minimum Route cables as close as possible to conductive parts loose cables or loops should be avoided cables should be flattened against conductive parts Keep power cables separate from battery cables Keep power cables separate from control cables at least 200mm The cables should only supply power to this appliance any branch offs or short outs intended to power another appliance are prohibited This is a recommendation for installation rather than an obligation The installing electrician should decide whether or not to use shielded cable depending on the EMC environment UECPS2 12 16 25 40 DEA DOC 28 ACRISTEC 4 2 6 Options The options are not bundled with standard CPS2 shore power units they are available from your reseller Only options marketed by Cristec may be mount
32. e sel ou de poussi res dans l unit d nergie Ces incidents peuvent g n rer une d gradation irr versible du mat riel et un danger potentiel pour l utilisateur L appareil doit tre positionn dans un endroit sec et bien ventil Dispositions vis vis des mat riels inflammables L unit d nergie ne doit pas tre utilis e proximit de mat riels liquides ou gaz inflammables Les batteries sont susceptibles d mettre des gaz explosifs pour l installation des batteries prendre en compte les prescriptions de leur constructeur Dispositions vis vis des courants de fuite accidentels la terre La barre de terre PE de l unit d nergie doit tre imp rativement raccord e la terre de l installation Elle doit tre raccord e avant toutes les autres bornes voir plan correspondant en annexe L unit d nergie doit tre ferm e avant toute mise sous tension le capot doit tre reli au ch ssis de l unit d nergie par les vis pr vues cet effet UECPS2 12 16 25 40 DEA DOC 6 ACRISTEC Courant de fuite accidentel entre phase et terre se conformer a la norme NFC15 100 pour les pr cautions d installation Faire r aliser les travaux de raccordement par un lectricien ou un installateur professionnel Courant de fuite accidentel entre circuit de charge et masse la d tection des courants de fuite accidentels a la masse doit tre assur e par un dispositif de protection e
33. ed with shore power units The following options are available for the CPS2 range Remote On Off charger control reference A M CPS2 A 5 metre cable On Off switch connect to K8 connector see drawing in appendix Remote Boost control reference BAD CPS2 A 5 metre cable Boost On Off switch connect to K11 see drawing in appendix Temperature probe reference STP CPS2 Compensates the charging voltage according to temperature 12V Charger 18mV C A 5 metre cable probe connect to K2 see attached drawing Digital display unit reference SEEL009104 Displays the state of the charger ON OFF the current of the charger the voltage on each of the 3 outputs and the rate of battery charge A 10 metre cable display unit connect to K3 Cables for analogue display units reference DEP V A CPS2 For connecting analogue voltmeter options 1 to 4 depending on the number of outputs to be monitored Bat D Bat 1 Bat 2 or the voltage upstream of the distributor and an ammeter A 5 meter cable connect to K10 see drawing in appendix 48x48mm analogue voltmeter to view the voltage of a particular output or the charger s voltage upstream of the distributor Reference VLT0012 CPS2 for 12Vcc chargers Connect to K10 with option DEP V A CPS2 48x48mm analogue voltmeter to view charger s total current connect to K10 with option DEP V A CPS2 Model Reference CPS2 12 16 AMP 12V 16A CPS2 CPS2 12 25 AMP 12V 25A C
34. es the following gt 1 metal box containing the battery charger s electronic functions and the 230VAC protection circuit breakers gt This operating manual This document applies to shore power units in the CPS2 CRISTEC range as listed on the cover The manual is intended for users installers and equipment maintenance staff Please read this manual carefully before working on the shore power unit This manual should be kept safely and consulted before attempting any repairs because it contains all the information required to use the appliance This document is the property of CRISTEC all the information it contains applies to the accompanying product CRISTEC reserves the right to modify the specifications without notice 1 1 PRECAUTIONS Precautions regarding overheating of the appliance This appliance is designed to be mounted on a vertical wall or partition as indicated herein It is imperative that there be a gap of 150mm around the shore power unit The installer must see to it that the temperature of the air at the input is lower than 40 C in extreme operating conditions Measures should also be taken to allow for the discharge of hot air on either side of the shore power unit The shore power unit must not be installed near a source of heat it should be installed in a well ventilated area The shore power unit s air inlets and outlets must not be obstructed Precautions regarding dust seepage and falling water The sho
35. g 18330q 1 28 pezseuuos sind3no su JON 25 e juaua1103e611q0 sed 5911105 saj SIFNO 1vg L 1 Lva 801395 1931810 JO ase andino Ino31eqo 18 S2313108 375 89 106 357 23 190 242 260 besz A A EA tat de surface AA 02 02 07 design large 118 Encombrement Unite energie CDS2 CPS2 12V 16A et 25A 47 Av P Mendes France 29000 QUIMPER Tel 02 98 55 5199 Fax 02 98 55 51 67 Mati re Finition Tol g n rale 1 Dessine JLb Le TS CRISTEC 0925100 b NFE 05 016 Ra Usinage NFE 02 3501 02 02 07 V rifi FPe N 19 G E D B ENAG SA 110 traits ne peut ment meme par ex YS 23161 2 41433 aasisoyne 2442 nad au sexa Jed yuaWNI0P 2 ae 80 15260 oN 86 19 SS 86 20 4 78 08 ES 86 20191 HMA YIdWIND 00062 eusseq sapuaiW AV 717 NOIX3NNO 07
36. ible entr e ou Dysfonctionnement interne de l unit d nergie ou Retomb e du disjoncteur diff rentiel d entr e Jaune Boost Allum Switch SW1 Boost en position OFF Absorption ou Swich SWI Boost en position ON et phase de Boost Absorption achev e Clignotant Switch SWI Boost en position ON et chargeur en cours de phase de Boost Absorption Eteint Dysfonctionnement interne de l unit d nergie ou Rupture du fusible de sortie Jaune Floating Allum Courant chargeur lt 15 du courant nominal phase de Floating Eteint Courant chargeur gt 15 du courant nominal Ces indicateurs sont visibles en fa ade de l appareil au travers de guides de lumi re et permettent une visualisation du mode de fonctionnement de l appareil 4 INSTALLATION Ce paragraphe traite des dispositions relatives l installation de l quipement L installation et la premi re mise en fonctionnement doivent tre assur es par un lectricien ou un installateur professionnel selon les normes en vigueur dans le cas des navires de plaisance se conformer a la norme internationale 15013297 L installateur devra prendre connaissance de ce manuel d utilisation et devra informer les utilisateurs des dispositions relatives a l utilisation et la s curit contenues au paragraphe 7 UECPS2 12 16 25 40 DEA DOC 12 4 CRISTEC 4 1 MONTAGE DE L UNITE D ENERGIE L unit d nergie CPS2 devra tre install e au plus pr
37. ies Cette fonction est temporis e dans le temps 4 heures 10 minutes et est inhib e automatiquement si la batterie est charg e arr t du Boost pour I batteries lt 15 de I chargeur nominal La fonction Boost peut galement tre inhib e par un switch 3 2 2 Disposition des switchs de configuration a SWI S lection de la fonction BOOST SW2 SWS S lection du type de batteries UECPS2 12 16 25 40 DEA DOC 9 ACRISTEC 3 2 3 Configuration en fonction du type de batteries Type de Batterie Disposition des Switchs 6 SWA sw3 sw2 SW1 Phase Phase LE ds Boost Boost Floating BAT TYPE 1 Plomb Calcium Etain ex OFF OFF OFF ON ON 15 1V 14 4V Delphi Delco Freedom BAT TYPE 2 Plomb Etanche OFF OFF ON OFF ON 14 3V 13 6V 3 Plomb G lifi ou Plomb OFF ON OFF OFF 14 1V 13 4V Calcium BAT TYPE 4 Plomb Ouvert avec entretien ON OFF OFF OFF ON 13 7V 13V lectrolyte libre HIVERNAGE pour BAT TYPE 1 BAT TYPE 2 OFF ON OFF OFF ON 14 1V 13 4V BAT TYPE 3 HIVERNAGE pour BAT TYPE 4 ON OFF OFF OFF ON 13 7V 13V Tension sur BAT 1 BAT 2 avec 10 du courant nominal avec une tol rance de 1 Tension sur BAT D BAT 1 ou BAT 2 0 4V environ 3 2 3 R glages L unit d nergie est configur e en sortie
38. ltage on certain types of accumulators may indicate they have sustained irreversible damage thereby precluding any possibility of recharging 53 TURNING THE SHORE POWER UNIT ON AND OFF The CPS2 shore power unit starts operating as soon as it is switched on input power cable connected and powered The CPS2 shore power unit stops operating when it is no longer powered up input power cable disconnected or the installation s circuit breaker in the OFF position ATTENTION if the charger On Off option is used the charger may not be in operation while the shore power unit is still being powered up dangerous voltage UECPS2 12 16 25 40 DEA DOC 30 4 CRISTEC 6 EQUIPMENT MAINTENANCE AND REPAIRS 6 1 OVERVIEW This paragraph deals with equipment maintenance and repairs Proper operation of the product and its service life are dependent on strict compliance with the following recommendations 6 2 EQUIPMENT MAINTENANCE Disconnect the shore power unit from the AC network before starting any maintenance work If appliances are in a dusty atmosphere vacuum clean them regularly since dust deposits may adversely affect heat release Check the state of battery charge every 3 months The tightness of nuts and screws should be checked annually to ensure efficient operation of the appliance particularly in hostile conditions vibrations shocks high variations in temperature etc A full technical inspection by a Cristec accredited engi
39. ndice de protection 21 Protection carte Tropicalisation par vernis hydrofuge ambiance marine Normes Marquage CE CEM NF EN6100 6 1 NF EN6100 6 2 NF EN6100 6 3 NF 6100 6 4 Marquage CE s curit NF EN60950 NF EN603635 2 29 Protections lectriques Contre les surtensions d entr e fugitives par casse varistance Contre les inversions de polarit en sortie par casse du fusible Contre les courts circuits et les surcharges en sortie Contre les chauffements anormaux par coupure chargeur sonde thermique interne 90 C Contre les surtensions de sortie UECPS2 12 16 25 40 DEA DOC 4 CRISTEC 3 FONCTIONNEMENT CONFIGURATION REGLAGES INDICATEURS 3 1 PRINCIPE DE FONCTIONNEMENT Les unit s d nergie CRISTEC permettent de disposer dans un m me coffret de la protection 230V du bord et d un chargeur de batteries L ensemble r pond aux normes europ ennes en vigueur et permet gr ce son coffret compact d optimiser l encombrement et le temps de montage La protection utilisateur se compose d un disjoncteur 16A 230V bipolaire diff rentiel 30 mA Les d parts du bord sont eux prot g s par 2 3 ou 4 disjoncteurs magn to thermiques DPN 10A La fonction chargeur est assur e par une carte lectronique d coupage H F directement issue de notre gamme de chargeurs CPS2 Ils sont con us sur la base d un convertisseur d coupage haute fr quence qui t
40. neer is recommended every five years This can also be done at our plant 6 3 EQUIPMENT REPAIR Disconnect the shore power unit from the AC power network and disconnect the batteries before undertaking any repairs When fuses have blown only use fuses of the type and size recommended in this manual Please contact a reseller or Cristec for any other repairs 7 SAFETY PRECAUTIONS 7 1 REFERENCE STANDARDS Class I equipment compliant with standard NF EN 60950 Installation instructions are set out in standard 15 100 and the specific 15013297 standard entitled pleasure boats electrical systems Installing distributed AC current 72 PERSONAL SAFETY PRECAUTIONS Only an electrician or professional installer should install the appliance The incoming AC power network should be cut off before working on the equipment 73 PRECAUTIONS REGARDING THE RISK OF FIRE AND EXPLOSIONS Only use the fuses listed herein Near batteries keep the room well ventilated do not smoke never use bare flames UECPS2 12 16 25 40 DEA DOC 31 ANCRISTEC 8 CE CERTIFICATION OF CONFORMITY DECLARATION OF CONFORMITY With the provisions of directive 89 336 CEE Electromagnetic compatibility And the provisions of directive 73 23 CEE Low voltage Manufacturer CRISTEC Address 47 Avenue Pierre Mend s France 29000 Quimper FRANCE Declare that the CPS2 shore power units 12V 16A 12V 25A 12V 40A Conform to the provisions of
41. ns should be taken on any installation prone to electrolytic phenomena Regulations require the presence of a battery cut off at the outputs on the and poles Precautions regarding lightning In areas highly exposed to lightning it may be advisable to install a lightning arrestor upstream of the shore power unit to safeguard it against irreversible damage Other precautions Never attempt to drill a hole in or machine the shore power unit s case this may damage components or cause metal chips or filings to fall on the charger s board Do not do anything that is not explicitly stated in this manual 1 2 WARRANTY The manufacturer disclaims the warranty and CRISTEC waives any liability whatsoever if the installation rules and instructions for use are not observed The warranty is valid for 36 months It covers parts and labour for equipment returned to the Quimper plant Only original parts recognized as being defective will be replaced under the warranty Our warranty does not cover 1 Failure to abide by this manual 2 Any mechanical electrical or electronic alterations to the appliance 3 Improper use 4 Presence of moisture 5 Failure to comply with power supply tolerances 6 Incorrect connections 7 Falls or impacts during transportation installation or use 8 Repairs carried out by anyone unauthorized by CRISTEC 9 Connection of any interfaces not supplied by CRISTEC 10 The cost of
42. onfiguration Settings switches F1 F2 Fusibles d entr e Input fuses F4 Fusible de sortie Output fuse LD1 1 02 1 03 Leds d tat State LEDs KLD1 KLD2 KLD3 Option LEDs ON Boost Absorption Floating deportees ON Boost Absorption Floating stand alone LED option UECPS2 12 16 25 40 DEA DOC 39 SA d crit d ENAG 19 18 8 2 17 16 15 _ 395 _ B i 11 10 9 O O OS NO 00 8 7 6 5 A 3 02 02 07 designtarge Th Encombrement Fimtions 2 Unite Energie CDS2 CPS2 12V 40A Tol g n rale 1 Usinage 02 3501 2 47 Av Mend s France Dessin e JLb Le 02 02 07 a T l 02 98 55 5 A rom pere V rifi FPe Fo 1 1 T l 02 98 55 51 99 CRISTEC verre 5 Fax 07 98 5 51467 N 0925200 B 5 R a 0 N M K H G F F D VS 32315182 41433 agsisoyne 2442 au syesyxa Jed e7 had V80 25260 oN 4 NSA ad guissaq 101 6 0 93 6 apyueng 76 79 SS 86 20 28 08 ES 86 20 191 YAdWIND 0
43. orption Floating Boost Absorption Floating gt 5 4 U boost U boost U floating U floating o 4 Hrs t 0 lt 4 Hrs t I out 1 1 Boost Absorption Floating Boost Absorption Floating nom I nom 15 1 nom 4 15 nom ol 4Hrs t 0 lt 4 Hrs t Boost Phase starts up automatically when the shore power unit is turned on if the battery is flat The current is then at maximum output Absorption Phase begins when the voltage has reached the maximum Boost level The current level starts falling These two phases combined last a maximum of 4 hours If the current falls below 15 of rated current the floating phase automatically kicks in Duration and current intensity depend on how charged the battery is Floating Phase starts after 4 hours or if output current has reached 15 of the shore power unit s rated current The voltage switches to the Floating value and the rated current continues to drop UECPS2 12 16 25 40 DEA DOC 25 ACRISTEC Boost in OFF position With this setting the CPS2 shore power unit produces a single stage Ul type load curve It generates a constant voltage supplying the current required by the battery ies Recharging time depends on the state of the battery being longer than when the boost is in the ON position U out charger 5 ee 0 t I 1 nom 0 t
44. packaging ands carriage 11 Apparent or latent damage sustained during shipment and or handling any such claims should be sent to the haulier Our warranty on no account provides for any form of compensation CRISTEC shall not be held liable for damage incurred as a result of bad using the shore power unit UECPS2 12 16 25 40 DEA DOC 21 ACRISTEC 2 TECHNICAL SPECIFICATIONS 2 1 UECPS2 12V 16A 12V 25A 12V 40A Model UECPS2 12 16 UECPS2 12 25 UECPS2 12 40 Input Voltage 230VAC 15 single phase Frequency From 47 to 63Hz Current intensity 230VAC 1 44 2A 3 24 Power factor 0 9 in rated conditions Efficiency gt 80 in rated conditions Input fuses F1 F2 Output Number of outputs 2 x 6 3A 250V Ref DEL MICRO FUSE 00346623MST 2 x 10A 250V 6 3x 32 3 separate outputs BAT D BAT 1 and BAT 2 integrated distributor Each output can be used on its own and supply the entire current Overall rated current 7 Rated power 16A 228W 25A 356W 40A 570W Load curve of charge selected using internal switch IU or IUoU Boost Absorption Floating factory setting Type of batteries See switch settings table Regulated and filtered output voltage See switch settings table Chargers can operate on DC supply Regulation tolerance before distributor and fuses lt 2
45. ransforme le signal alternatif en une tension continue r gul e et filtr e Ils peuvent fonctionner en chargeur de batteries et en alimentation courant continu Le fonctionnement de l unit d nergie est enti rement automatique apr s s lection pr alable du type de batterie et du type de charge Elle peut rester raccord e de fa on permanente aux batteries et ne n cessite pas d tre d connect e lors du d marrage moteur application marine car quip e de diodes anti retour L appareil d livre une tension adapt e la recharge de 1 2 ou 3 batteries s par es r partiteurs de charge int gr s s paration des batteries Tous les mod les sont dot s d une sortie adapt e la recharge de la batterie moteur sortie BAT D application marine Le chargeur peut d biter au maximum le courant nominal r parti sur chaque sortie en fonction du besoin utilisation batterie Chaque sortie peut d biter le courant nominal Toutes les sorties ne sont pas obligatoirement connecter Cependant si une seule sortie est utilis e il est recommand de relier les sorties BAT1 BAT2 et BAT D entre elles facultatif 3 2 CONFIGURATION DES SWITCHS REGLAGES INDICATEURS 3 2 1 Descriptif Les unit s d nergies CPS2 sont quip es de switchs permettant de configurer le chargeur en fonction du type de batteries et d application Les chargeurs CPS2 sont dot s de la fonction Boost qui permet une recharge plus rapide des batter
46. re power unit should be located so as to prevent penetration of damp liquids salt and dust any of which could cause irreparable damage to the equipment and be potentially hazardous for the user The appliance should be installed in a dry and well ventilated place Precautions regarding inflammable materials The shore power unit should not be used near inflammable materials liquids or gases The batteries can emit explosive gases please follow the manufacturer s instructions carefully when installing them Precautions regarding accidental earthing leaks The PE terminal must be earthed and connected before any of the other terminals see relevant diagram in the appendix The shore power unit must be closed before it is turned on the cover must be fixed to the shore power unit s body with the screw provided for the purpose UECPS2 12 16 25 40 DEA DOC 20 4 CRISTEC Accidental leakage current between phase and earth standard NFC15 100 should be followed when installing Use the services of an electrician or professional installer to make the necessary connections Accidental leakage current between the charge circuit and the earth accidental current leakage at the earth must be detected by means of an independent protective device outside the shore power unit a residual current device or an insulation detector The installer should decide on the rating and nature of the protection according to the risks Special precautio
47. rge des batteries C ble de 10 m tres afficheur connecter sur K3 C bles pour afficheurs analogiques r f rence DEP V A CPS2 Permet de connecter les options analogiques voltm tre de 1 4 en fonction du nombre de sorties contr ler Bat D Bat 1 Bat 2 ou tension avant r partiteur et amp rem tre C ble de 5 m tres connecter sur K10 voir plan en annexe Voltm tre analogique 48x48mm pour visualiser la tension d une sortie ou la tension du chargeur avant r partiteur R f rence VLT0012 CPS2 pour les chargeurs 12 A connecter sur K10 avec l option DEP V A CPS2 Amp rem tre analogique 48x48mm pour visualiser le courant total du chargeur connecter sur K10 avec l option DEP V A CPS2 Mod le R f rence CPS2 12 16 AMP 12V 16A CPS2 CPS2 12 25 AMP 12V 25A CPS2 CPS2 12 40 AMP 12V 40A CPS2 Option LEDs d port es r f rence LED DEP CPS2 C ble de 5 m tres connecter sur KLD1 KLD2 KLD3 UECPS2 12 16 25 40 DEA DOC 15 4 CRISTEC 5 MISE EN SERVICE Ce paragraphe num re les op rations effectuer pour la mise en service de l quipement Il convient de respecter strictement ces instructions avant la premi re mise sous tension 5 1 RESEAU D ENTREE Toutes les unit s d nergies CPS2 peuvent fonctionner automatiquement et indif remment partir du r seau monophas 230VCA 15 et de 47 63Hz Caract ristiques distribution CA e Protection g
48. xt rieur l unit d nergie dispositif courant diff rentiel r siduel ou contr leur d isolement Le calibre et la nature de la protection seront adapt s par l installateur en fonction des risques Des pr cautions particuli res sont recommand es sur toute installation susceptible de craindre des ph nom nes lectrolytiques La r glementation impose la pr sence de coupe batteries en sortie sur le p le et le p le Dispositions vis vis des chocs de foudre Dans les zones g ographiques fortement expos es il peut tre utile de placer un parafoudre en amont de l unit d nergie afin d viter toute d gradation irr versible de ce dernier Autres dispositions Ne pas percer ou usiner le coffret de l unit d nergie risque de casse de composants ou de projection de copeaux ou limailles sur la carte chargeur Tout ce qui n est pas stipul dans ce manuel est rigoureusement interdit 12 GARANTIE Le non respect des r gles d installation et d utilisation annule la garantie constructeur et d gage la soci t CRISTEC de toute responsabilit La dur e de garantie est de 36 mois Elle s applique aux pi ces ainsi qu la main d uvre pour un mat riel rendu usine de Quimper Seuls les l ments reconnus d fectueux d origine seront remplac s dans le cadre de la garantie Notre garantie est exclue pour 1 Non respect du pr sent manuel 2 Toute modification et intervention m canique

Download Pdf Manuals

image

Related Search

Related Contents

page catalogue  evaluación de la campaña de inspección y control de alquiler y  MAINTENANCE INTERVALS - Safety  Station d`accueil avec ampli pour iPod/iPhone  52X-VW USER`S MANUAL  Rola Bicycle Accessories 59403 User's Manual  Fase 1: Conectividade - Integração das Clearings da    Cooler Master Backplate for AMDK8  