Home

FLEX STRIP CONTROL MANUEL D`UTILISATION

image

Contents

1. Technical Specifications Function Installation DMX512 Address setting How to control the fixture DMX 512 Connection Troubleshooting Fixture Cleaning 11 1 Safety Introductions A Please read the instructions carefully which includes important WARNING information about the installation operation and maintenance Please keep this User Manual for future consultation If you sell the fixture to another user be sure that they also receive this instruction booklet Unpack and check carefully there is no transportation damage before using the fixture Before operating ensure that the voltage and frequency of power supply match the power requirements of the fixture Disconnect mains power before servicing and maintenance Use safety chain when fixes this fixture In the event of serious operating problem stop using the fixture immediately Never try to repair the fixture by yourself Repairs carried out by unskilled people can lead to damage or malfunction Please contact the nearest authorized technical assistance center Always use the same type spare parts Do not touch any wire during operation and there might be a hazard of electric shock To prevent or reduce the risk of electrical shock or fire do not expose the fixture to rain or moisture There are no user serviceable parts inside the fixture Do not open the housing or attempt any repairs by yourself In the unlikely event your fixture may require service
2. DMX512 Address Setting Each fixture needs to have a start address set to receive the data sent by the controller The address number is between 0 511 usually 0 amp 1 are equal to 1 The address also know as the start channel is the first channel used to receive instructions from the controller There are three ways to set the fixture DMX start address A DMX address setting by dip switches B Auto DMX addressing C Remote DMX address setting by universal DMX controller If you use the function B C or D to set the DMX start address the fixtures of the chain all DIP switch MUST be set to OFF When you set the address by DMX controller and dip switch at the same time the order of the DMX controller will be invalid A DMX address setting by dip switches 1 Set the start address by dip switch as the diagram below 2 Hold the AUTO DMX ADDRESS button for about 5 seconds the LED lights blinking indicating the address is set successfully a Alkali dK BEL Neel a Bo a bl les 14 e Examples Channel 01 dip on 1 1 Channel 05 dip on 1 3 1 4 5 Channel 09 dip on 1 4 1 8 9 Channel 13 dip on 1 3 4 13 B Auto DMX addressing 1 The DMX address of fixture can be set automatically Set all dip switches to OFF and hold the AUTO DMX ADDRESS button of the first unit for about 5 seconds the fixture will be set the DMX start address to 1 and the other fixtures of the chain will be set their ow
3. Their DMX input cables connect the last fixture DMX output cable daisy chain Any fixture can act as a Master or as a Slave 7 DMX512 Connection The DMX 512 is widely used in intelligent lighting control with a maximum of 512 channels 17 COMMON DMX INPUT 3 3 OUTPUT 2 DMX 2 Termination reduces signal errors and to avoid signal transmission problems and interference Itis always advisable to connect a DMX terminal 2 Resistance 120 ohm 1 4W between pin2 DMX and y pin3 DMX of the last fixture lt If you using a controller with 5 pins DMX output you need to use a 5 to 3 pin adapter cable At last unit the DMX cable has to be terminated with a terminator Solder a 120 ohm 1 4W resistor between pin 2 DMX and pin 3 DMX into a 3 pin XLR plug and plug it in the DMX output of the last unit Connect the unit together in a daisy chain by XLR plug from the output of the unit to the input of the next unit The cable can not branched or split to a Y cable DMX 512 is a very high speed signal Inadequate or damaged cables soldered joints or corroded connectors can easily distort the signal and shut down the system The DMX output and input connectors are pass through to maintain the DMX circuit when one of the units power is disconnected Each lighting unit needs to have an address set to receive the data sent by the controller The address number is between 0 511 usually 0 amp 1 a
4. NICOLSI E lt 4 L PTT FLEX STRIP CONTROL MANUEL D UTILISATION Nous vous recommandons de lire attentivement le manuel avant toute utilisation TABLE DES MATIERES Instructions de s curit Caract ristiques techniques Fonctions Installation de l appareil Configuration DMX 512 R glage de l appareil Connexion DMX 512 D pannage de l appareil Entretien de l appareil 1 Instructions de s curit Lire attentivement les consignes ci apr s Elles contiennent des informations importantes sur la s curit de l installation ainsi que sur l utilisation et la maintenance de l quipement e Conservez le pr sent manuel avec l quipement pour r f rence ult rieure En cas de vente de l quipement un autre utilisateur il est important que le pr sent manuel soit joint l quipement afin que le nouvel utilisateur dispose des informations n cessaires son utilisation et puisse prendre connaissance des mises en gardes relatives la s curit e Avant tout premi re utilisation d ballez le set et v rifiez qu il ny ait pas eu de dommages pendant le transport e Avant tout premi re utilisation assurez vous que lalimentation soit compatible la tension locale e D branchez l appareil du secteur avant de faire toute r paration ou entretien de l appareil e Utilisez des lingues de s curit pour fixer l appareil e Si vous rencontrez des probl mes l utilisation teignez
5. O permet de d marrer l adresse automatiquement MICROPHONE r cepteur voix pour le contr le du son FICHE ALIMENTATION prise pour alimentation CONNECTEURS pour contr leur LED WALL uniquement en option SIGNAL SORTIE signal de sortie et alimentation pour les flexibles lumineux 4 Installation de l appareil 1 Assurez vous que l alimentation est teinte avant de brancher ou de connecter les flexibles lumineux 2 D visser les vis et connectez les fils comme indiqu sur le sch ma ci dessous 3 Resserrer les vis correctement i 2 3 4 5 6 T 8 9 FLEX strip control LED Wall En positionnant le switch sur OFF le mode standby s active LED HC50 cians les LED s teignent En positionnant le switch sur ON les LS Le LED se rallument LED HC50 GND GND i F OV OV 12V 12V 24 Remarque Nous vous rappelons que la charge maximale est de 50W 5 Configuration DMX 512 Chaque appareil flexible lumineux a besoin d avoir une adresse DMX pour recevoir les informations envoy es par le contr leur L adresse se situe entre 0 511 o O et 1 seront gaux 1 L adresse aussi appel e canal de d part est le 1 canal utilis pour recevoir les donn es du contr leur ll y 3 fa ons de r gler l adresse DMX 1 A l aide des dip switch 2 En mode auto 3 A l aide d un contr leur DMX universel Remarque si vous utilisez les configurations 2 et 3 pour r gler l adresse DMX nous vo
6. er appareil le cable DMX doit avoir un bouchon de terminaison afin de r duire les d fauts du signal Il faut alors souder une r sistance de 120 Ohm 1 4W entre la borne 2 DMX et la borne 3 DMX dans une prise XLR 3 points Raccordez la a la sortie DMX du dernier appareil 3 Faites une chaine avec les appareils en connectant la sortie de la prise XLR de l appareil a l entr e de l appareil suivant Le cable ne doit pas tre branche un cable en Y Des cables inappropri s ou endommag s des joints soud s ou des connecteurs rouill s peuvent facilement tre l origine de la d formation du signal et couper le syst me 4 La sortie DMX et les connecteurs d entr e sont travers s par le courant pour maintenir le circuit DMX 5 Chaque unit doit avoir une adresse DMX r gl e pour recevoir les donn es envoy es par le contr leur Le nombre d adresse est entre 0 511 habituellement O et 1 sont gaux a 1 6 Les 3 points XLR sont plus utilis s que les 5 points XLR 3 points XLR Borne 1 La terre Borne 2 signal n gatif Borne 3 signal positif 5 points XLR Borne 1 La terre Borne 2 signal n gatif Borne 3 signal positif 8 D pannage de l appareil Vous trouverez ci dessous une liste de probl mes qui pourraient survenir lors de l utilisation de votre appareil Nous vous apportons quelques suggestions pour rem dier facilement la situation A L appareil ne fonctionne pas 1 V rifiez la tension s
7. gnal DMX et activer les programmes int gr s 5 3 Contr leur DMX universel Assurez vous que les c bles DMX de tous les appareils soient connect s Connectez le 1 appareil votre contr leur DMX universel Connectez tous les appareils l alimentation pour qu ils soient allum s 6 Mettez sur 0 valeur 000 tous les canaux DMX de votre contr leur DMX Adressez une valeur DMX tous les canaux des appareils de votre choix valeur max 255 Appuyez sur le bouton AUTO DMX ADDRESS bouton 5 Si vous voulez qu un autre appareil recoive la m me adresse DMX appuyez sur son bouton DMX AUTO ADDRESS bouton 5 Exemple Adresse DMX de l appareil 106 Connectez l appareil au contr leur DMX Mettez les canaux DMX du contr leur sur 0 000 Puis r glez le canal DMX 106 Appuyez sur le bouton DMX AUTO ADDRESS gt L adresse DMX de votre appareil est 106 ll y a 3 fa ons de r gler l appareil 1 A l aide des dip switch 2 A laide du contr leur DMX universel 3 Mode Master Slave 6 1 Dip Switch Use Dip switch 3 4 5 to choose chase speed 1 8 Fade Use Dip switch 3 4 5 to choose fade speed 1 8 Color Use Dip switch 6 7 8 9 to choose color 16 ON1 234567 8 9 10 6 2 Contr leur DMX universel Si vous utilisez un contr leur avec une sortie DMX 5 points vous avez besoin d utiliser un adaptateur afin d avoir une sortie DMX 3 points Les apparei
8. imm diatement l appareil N essayez pas de r parer l appareil par vous m me Les r parations effectu es par du personnel non qualifi peuvent engendrer des dommages II est important de contacter votre revendeur pour toute r paration Toujours utiliser des pi ces de m me type e Ne touchez aucun fil lectrique pendant l utilisation vous pourriez recevoir un choc lectrique e Afin d viter tout risque de choc lectrique ou d part de feu nous vous recommandons de ne pas exposer l appareil la pluie ou l humidit e n y a pas de pi ces d tach es l int rieur de l appareil Ne tentez pas de r parer ou d ouvrir l appareil par vous m me Dans le cas o votre appareil n cessite une r paration contactez votre revendeur 2 Caract ristiques techniques e Contr leur compact pour tous les types d appareils LED en 24V e Alimentation fournie e Programmes int gr s d clench s par la musique en mode MASTER SLAVE e 3 configurations pour l adresse DMX e Alimentation AC 230V 50Hz e Tension DC 24V e Charge maximale 50W e Canaux Canal 1 Rouge Canal 2 Vert Canal 3 Bleu Canal 4 Dimmer Strobe e Dimensions 332 x 70 x 40 mm e Poids 1 kg G Pi Sortie DMX Sortie du signal DMX Entr e DMX Entr e du signal DMX LED indique l tat de l appareil DIP SWITCH permet de r gler l adresse DMX ou de choisir les fonctions de l appareil ADRESSE DMX AUT
9. ls ont 4 canaux Veuillez vous r f rez au tableau ci dessous DMX512 Configuration Ch1 Ch2 Ch3 Ch4 RED GREEN BLUE DIMMER STROBE 255 100 248 255 OPEN AAA 201 247 AA SOUND 191 200 CHASE 8 190 0 7 CLOSED 6 3 Master Slave L appareil vous permet de relier 16 appareils entre eux et les faire fonctionner sans contr leur Dans la configuration Master Slave le 1 appareil contr le les autres automatiquement en ex cutant un effet de lumi re se d clenchant au son de la musique Cette fonction est int ressante d s lors o vous voulez r aliser une d monstration instantan e Le c ble correspondant l entr e DMX du 1 appareil ne sera connect e aucun appareil et les autres appareils seront automatiquement en mode slave Leurs c bles correspondant l entr e DMX seront connect s la sortie DMX du dernier appareil 7 Connexion DMX 512 Le mode DMX512 est couramment utilis pour r aliser des effets de lumi res 512 est le nombre maximum de canaux COMMON DMX INPUT DMX OUTPUT Termination reduces signal errors and to avoid signal transmission problems and interference It is always e advisable to connect a DMX terminal LR Resistance 120 ohm 1 4W between pin2 DMX and pin3 DMX of the last fixture 1 Si vous utilisez un contr leur avec une sortie DMX 5 points vous avez besoin d utiliser un adaptateur afin d avoir une sortie DMX 3 points 8 2 Sur le derni
10. n Here are some suggestions for easy troubleshooting A The fixture does not work 1 Check the connections of power and main fuse 2 Measure the mains voltage on the main connector 18 EJ ce z 19
11. n DMX start address automatically 2 The LED fixtures use four channels the next fixture s will be automatic calculate their own DMX address not need to calculate the DMX channels of each fixture in the chain Fixture 1 1 Fixture 2 5 Fixture 3 9 Fixture 4 13 Fixture 3 No need to turn the fixture off when you change the DMX address as new DMX address setting will be effect at once Every time you turn the fixture on it will be ready to receive DMX signal or run the built in programs D Remote DMX address setting by universal DMX controller e Make sure the DMX cables of all units are connected e Connect the first unit to a universal DMX controller e Connect all units to the mains so they are switched on e Set all DMX channels on your DMX controller to zero value 000 e Set the DMX channel that you want to assign as DMX start address on you unit tot maximum value 255 e Press the Auto DMX address button on the unit shortly e f you want to set another unit to the same DMX start address simply press it s Auto DMX address button and it will receive the same address e Done An example to make things clear e We will set the DMX start address of a unit to 106 e Connect the unit to the DMX controller as described above and make sure all is switched on e Set all DMX channels on the controller to zero 000 15 e Now set DMX channel 106 to maximum 255 e Press the Auto DMX address b
12. please contact your nearest dealer 2 Technical Specifications A compact LED controller for all kinds of DC 24V passive RGB Fixtures Come with switch power supply inside Built in programs under Master Slave mode triggered by music 4 different ways of DMX addressing Terminals for linking LED Wall Dimmer and it provides power to LED Wall Dimmer Power input 230V 50Hz 40 Power output DC 24V Max Load 50W e Channels Channel 1 Red Channel 2 Green Channel 3 Blue Channel 4 Dimmer Strobe e Dimension 332 x 70 x 40mm e Weight 1 kg DO OO 1 DMX OUTPUT output DMX signal 2 DMX INPUT input DMX signal 3 LED show the status of the unit 4 DIP SWITCH used to set the start address of the unit or choose functions 5 AUTO DMX ADDRESS used to set start address automatically 6 MICROPHONE used to receive voice for sound control 7 POWER SOCKET for power input 8 LED WD CONNECTOR used to receive the signal of LED WD only 9 SIGNAL OUTPUT output signal and power for light 4 Installation 1 Ensure that mains power supply is off before installing or wiring the LED fixture 2 Unscrew the screws and connect the wires as diagrams below 3 Tight the screws 13 Set the switch to OFF the LED lights will go into standby mode set it ON the lights will revive LED HC50 4 LED light CAUTIONS the LED controller total output power consumption is 50 watt 5
13. re equal to 1 The end of the DMX 512 system should be terminated to reduce signal errors 3 pin XLR connectors are more popular than 5 pin XLR 3 pin XLR Pin 1 GND Pin 2 Negative signal Pin 3 Positive signal 5 pin XLR Pin 1 GND Pin 2 Negative signal Pin 3 Positive signal B Not responding to DMX controller 1 DMX LED should be on If not check DMX connectors and cables to see if link properly 2 Ifthe DMX LED is on and no response to the channel check the address settings and DMX polarity 3 If you have intermittent DMX signal problems check the pins on connectors or on PCB of the fixture or the previous one 4 Try to use another DMX controller 5 Check if the DMX cables run near or run alongside to high voltage cables that may cause damage or interference to DMX interface circuit C No response to the sound 1 Make sure the fixture does not receive DMX signal 2 Check microphone to see if it is good by tapping the microphone 9 Fixture Cleaning The cleaning of internal must be carried out periodically Cleaning frequency depends on the environment in which the fixture operates damp smoky or particularly dirty surrounding can cause greater accumulation of dirt e Clean with soft cloth using normal glass cleaning fluid e Always dry the parts carefully e Clean the external at least every 20 days 8 Troubleshooting Following are a few common problems that may occur during operatio
14. ur le connecteur principal 2 V rifiez les branchements de votre alimentation et le fusible principal B L appareil ne r pond pas au contr leur DMX La LED DMX doit tre allum e Si ce n est pas le cas v rifiez les connecteurs et les cables pour voir si le raccordement est correct 2 Si la LED DMX est allum e et que le canal ne r pond pas v rifiez les r glages de l adresse et la polarit du signal DMX 3 Si vous rencontrez des probl mes avec le signal DMX mais de fa on intermittente v rifiez les connecteurs ou la carte lectronique de l appareil d faillant ainsi que de l appareil pr c dent 4 Essayer d utiliser un autre contr leur DMX 5 V rifiez l absence d interf rences entre les c bles lectriques C Les appareils ne r pondent pas la musique 1 Assurez vous que les appareils ne re oivent pas de signal DMX 2 V rifiez si le micro fonctionne en tapotant dessus 9 Entretien de l appareil Le nettoyage de l appareil doit tre fait r guli rement La fr quence du nettoyage de l appareil d pend essentiellement de l environnement dans lequel l appareil est install pi ces humides enfum es ou sales e Nettoyez l appareil avec un chiffon doux et utilisez un liquide de nettoyage pour vitres e Il est toujours recommand d essuyer correctement toutes les pi ces de l appareil e Nettoyez l appareil au moins tous les 20 jours EI 10 TABLE OF CONTENTS Safety Instructions
15. us recommandons de positionner tous les dip switch des appareils sur OFF Si vous r gler l adresse DMX par un contr leur DMX et l aide des dip switch en m me temps les informations donn es par le contr leur DMX seront invalides 1 Positionnez les dip switch comme indiqu sur le sch ma ci dessous 2 Maintenez le bouton AUTO DMX ADDRESS bouton 5 pendant 5 secondes la LED clignote vous indiquant que l adresse a t correctement enregistr e Co vi ee e es es es er ee ee 70 LOIR RRESES EEE TR OU Exemples Canal 01 Dip on 1 1 Canal 05 dip on 1 3 1 4 5 Canal 09 dip on 1 4 1 8 9 Canal 13 dip on 1 3 4 1 4 8 13 5 2 Mode automatique 1 L adresse DMX de chaque appareil peut tre enregistr e automatiquement Positionnez tous les Dip Switch sur OFF et maintenez le bouton AUTO DMX ADDRESS du 1 appareil bouton 5 pendant 5 secondes L adresse de cet appareil sera 1 et les autres appareils de la chaine recevront leur adresse DMX automatiquement 2 Les appareils ont 4 canaux ainsi les appareils suivants recevront leur adresse automatiquement sans avoir faire de calcul pour trouver l adresse DMX de chaque appareil de la chaine appareil 1 1 appareil 2 5 appareil 3 9 appareil 4 13 3 Il n est pas n cessaire d teindre l appareil quand vous changer l adresse DMX A chaque fois que vous allumez l allumez l appareil celui ci est pr t recevoir le si
16. utton on the unit shortly e Done Your unit now has DMX address 106 6 How to control the fixture There are three ways to control the fixture A Control by DIP switches B Control by Universal DMX controller C Master Slave operation A Control by DIP switches UUW ON12345 67 8 9 10 UU ON123 45 67 8 9 10 OCC ON123 45 67 8 9 10 BULLI ON 1 23 4 5 6 7 8 9 10 Use Dip switch 3 4 5 to choose chase speed 1 8 UU ON1 23456 7 8 910 Use Dip switch 3 4 5 to choose fade speed 1 8 ann ON12345678 910 Use Dip switch 6 7 8 9 to choose color 16 B Control by universal DMX controller If you use a controller with 5 pins DMX connector you need to use a 5 to 3 pin adapter The fixture uses four channels Please refer to the following diagram to use your controller to activate the fixture 16 DMX512 Configuration GREEN BLUE DIMMER STROBE 255 100 255 100 255 100 OPEN AAA 201 247 WM y SOUND 181 200 CUASE 0 0 0 0 0 0 C Master Slave operation The fixture will allow you to link 16 fixtures together and operate without a controller In Master Slave mode the first fixture will control the others to give an automatic sound activated synchronized light show This function is good when you want an instant show The first fixture it s DMX input cable will have nothing connect it and the other fixtures will be set in slave mode automatically