1. S2 Sensore Vap Benzina Gasoline Vap Sensor Capteur pour vapeurs d Essence Fig 1 Dimensioni Size Dimensions TECNOCONTROL S r l Via Miglioli 47 SEGRATE MI Tel 02 26 92 28 90 Fax 02 21 33 734 Centrale rivelazione gas Gas Central Unit Centrale de d tection Ingressi 4 20 mA 4 20 MA Imputs Entre en 4 20 mA Vap Benzina Petrol Vap Vapeurs d Essence 5 4 12 24Vdc Alimentazione Power Supply Alimentation 1 Uscita CO 4 20 mA CO 4 20 mA Output Sortie pour CO en 4 20 mA S2 Uscita Benzina 4 20 mA Petrol vap 4 20 mA Output Sortie pour Essence en 4 20 mA TP1 S1 Test Uscita CO CO Output Test Sortie Test CO 40 200mV TP2 S2 Test Uscita Benzina Petrol Vap Output Test Sortie Test Essence 40 200mV YI Fig 2 Schema di collegamento Wiring diagram Sch ma _ Sensore CO CO Sensor Capteur pourcO_ CO _ Sensore CO CO Sensor Capteurpour CO Sensor Capteur pour CO sens Tasti Tasti Ke Touches e Sensore Vap Benzina Petrol Vap Sensor Capteur pour vapeurs d Essence 700 650 600 500 400 350 300 200 100 50 0 5 10 15 20 25 28 10 8 24 Vdc Alimentazione Power Supply Ali
2. GAS GAZ Gas Utilizzato ppm ppm letti come CO Test Gas Used ppm Gaz utilis ppm CO concentration equivalent ppm ppm lu comme CO Ossido di carbonio Carbon Monoxide 100 100 Biossido di azoto Nitrogen dioxide 30 10 Acetato di etile Ethyl acetate 200 0 Ammoniaca Ammonia 100 0 Anidride carbonica Carbon dioxide 5000 0 Biossido di zolfo Sulfur dioxide 25 0 Cloro Chlorine 1 n d Etanolo Ethanol 2000 lt 50 Etilene Ethylene 100 lt 80 Idrogeno Hydrogen 500 230 Idrogeno Solforato Hydrogen sulphide 10 0 Metano Methane 5000 0 Ossido di azoto Nitric oxide 30 30 Toluene Toluene 50 n d TECNOCONTROL S r l Via Miglioli 47 SEGRATE MI Tel 02 26 92 28 90 Fax 02 21 33 734 IST 2255 CB01 01 Istruzione User s Manual Manuel d utilisation Pag 11 11 S1 Sensore CO CO Sensor Capteur pour CO
3. TECNOCONTROL S r l Via Miglioli 47 SEGRATE MI Tel 02 26 92 28 90 Fax 02 21 33 734 IST 2255 CB01 01 Istruzione User s Manual Manuel d utilisation Pag 7 11 CALIBRATION CHECKS no Code required this operation allows affecting a real functional test of the equipment with gas after the Calibration routine or after the installation The Calibration Check routine should be done during the periodic maintenances because this is the only method to verify the Sensors real functioning The Calibration Check should be done using the respective sample gas bottles as explained up in the box For the CO gas sensor S1 no need to insert the code apply directly to the gas For the sensor S2 for Petrol Vapours before applying the gas to run the code __ F2 F1 F2 F1 Insert the TC011 over the respective sensor holder adjust the sample gas bottle valve as the flow meter indicates around 0 3 l mins see Fig 3 Verify with a voltmeter connected to the Test Point TP1 and S1 that the CO value reaches in 2 3 minutes a reading between 190 and 210mV corresponding to 20 mA output and the Gas Central Unit should be display about 300 ppm 20 While on the Test Point TP2 and S2 for the Petrol Vap The value reaches in 2 3 minutes a reading between 190 and 210mV corresponding to 20 mA output and the Gas Central Unit should be display about 20 LIE 2 Note that the value result is more different is necessary to reca
4. tre fix avec des colliers de fa on ce que le capteur pour les vapeurs d essence se trouve environ 30cm du sol e CO est un peu plus l ger que l air et les vapeurs d essence sont plus lourd que l air RACCORDEMENTS ELECTRIQUES Fig 2 la distance maximale laquelle chaque d tecteur peut tre raccord es la centrale est indiqu e dans le Tableau 1 en fonction de la section du c ble utilis On utilise normalement un c ble cran poss dant 4 conducteurs Si l on utilise une alimentation 12Vcc la r sistance maximale de charge RL sera de 50 Q si on utilise une alimentation 24Vcc la RL sera de 500 Q Fig 4 Les borniers S1 S2 sont situ s sur la carte principale et sont de type brochable et il est n cessaire de le d brocher pour effectuer les connexions Pr ter attention en les r ins rant tant donn qu ils sont polaris s IMPORTANT Une fois termin e l installation pour adapter les capteurs aux conditions ambiantes le mettre sous tension attendre 60 120 minutes environ et puis ex cuter le R glage du Z ro voir V rifications et Calibrage COMPATIBILITE AVEC D AUTRES CENTRALES En cas d utilisation d une centrale diff rente de Tecnocontrol calculer la r sistance maximale de charge en utilisant le graphique selon la Fig 4 L alimentation sous 24Vcc est conseill e INSTRUCTIONS LA VIE UTILE DES CAPTEURS en air propre est 3 4 ans en moyenne pour le capteur de CO S1 et est 5 ans e
5. have the key pressure recognized hold pressing it for around a second until the Green LED doesn t switch off for a moment with one Buzzer beep for F1 and two Buzzer beeps for F2 Then the next key can be pressed Then buzzer beeps along to confirm the validity of the inserted code In case of error it is enough to wait around 10 seconds and the sequence signalled by three Beeps will be automatically erased CALIBRATION KIT SAMPLE GAS BOTTLES for Calibration Check and Calibration please only using two mixture 300ppm CO in Nitrogen and 0 44 v v 20 LEL Methane in Air It is possible to use either the disposable one litre cylinders with adjust valve or the high pressure ones with reduction gear Is also necessary the Tecnocontrol Calibration Kit model TC011 INSTRUMENT OPERATION CHECK Check Code F2 F2 F1 F1 this function allows to effect a functional test of the equipment After having put the system in safety and inserted the Code Test all LED are switched off Then they will switch on in sequence the LED from the yellow up to the red The two 4 20mA outputs remain unchanged At the end all the LED will remain lighted for around 5 seconds then the central returns at the conditions of normal operation It is advisable to perform this operation every 6 12 months according to the use Note this function is not working if one or both the red LED has already turned on ZERO ADJUST Zero Code F2 F1 F1 F2 This functi
6. F1 F1 F1 F2 F1 Attendere finch si accendano il corrispondente LED Giallo e Verde fissi ed il LED Rosso cominci a lampeggiare Infilare il TC011 sul corrispondente portasensore regolare l afflusso del gas in modo che il flussometro indichi circa 0 3 l min vedi fig 3 Attendere circa 2 3 minuti poi quando il LED Rosso si accende fisso e mentre ACCESO fisso premere il tasto F2 sulla targa dell apparecchio e tenerlo premuto finch il Cicalino emette in lungo Bip e il LED Rosso rimane spento per almeno 2 secondi se il LED Rosso continua a lampeggiare ripetere l operazione Chiudere la bombola e rimuovere il TC011 A questo punto si possono verificare due casi LED Giallo e Verde accesi Jo calibrazione stata eseguita correttamente dopo 8 secondi l apparecchio si spegne e si riavvia automaticamente in funzionamento normale vedi capitolo FUNZIONAMENTO Preriscaldo LED Giallo acceso la calibrazione fallita In questo caso dopo 8 secondi si riavvia automaticamente e dopo il reriscaldo ripetere la procedura di Calibrazione senza reinserire il Codice Se la condizione persiste anche dopo la sostituzione della Cartuccia sar necessario inviare il rilevatore al fornitore per la riparazione VERIFICA serve per controllare la corretta risposta del rilevatore al Gas e pu essere eseguita sia dopo la Calibrazione sia dopo l installazione ma va eseguita soprattutto durante le manutenzioni periodich
7. clignotement des deux LED Rouges et la sortie passe 4 0 mA Nous conseillons d ex cuter cette op ration si n cessaire 2 3 heures apr s l installation ou apr s le changement de la Cartouche Capteur et p riodiquement en fonction des conditions ambiantes Remarque n est pas possible d ex cuter l op ration si la LED Rouge est allum e ou si la sortie S1 est sup rieure 4 8 mA 15 ppm de CO ou la sortie S2 est sup rieure 12 mA 10 LIE des Vapeurs d essence Dans ce cas il est n cessaire de proc der la recalibration ou bien de substituer la Cartouche Capteur ETALONNAGE cette fonction permet l talonnage des Cartouches Capteurs Chacune avec son propre code et le gaz respectif Durant la proc dure une rare possibilit existe que la LED Jaune clignote chaque 8 secondes dans ce cas interrompre la proc dure puis ex cutez le contr le en coupant et en r tablissant l alimentation du d tecteur En cas de persistance il sera n cessaire de remplacer et ou renvoyer le d tecteur au fournisseur pour r paration Important Durant l op ration d talonnage l appareil porte la sortie correspondante S a OmA L talonnage doit tre ex cut exclusivement en air propre milieu sans la pr sence de gaz toxiques ou autres A l aide des touches ex cuter le Code d Etalonnage correspondant Le Code d talonnage pour le capteur n 1 plac directement sous le boitier pour CO est F2 F2 F2 F1 F2 F1 Le
8. e di taratura TS255CB hanno due segnali d uscita 4 20mA lineari con Fondo Scala di 300 ppm parti per milione per il CO S1 e del 20 LIE Limite Inferiore d Esplosivita per Vapori di Benzina S2 Queste due uscite vanno collegate a due ingressi delle nostre centrali rilevazione gas Sul coperchio sono visibili i tasti a sfioramento F1 e F2 per le operazioni di verifica e calibrazione utilizzabili solo tramite codice e i 5 LED che indicano le condizioni d esercizio LED Rosso ALARM S1 Segnalazione ottica d allarme 150 ppm CO LED Rosso ALARM S2 Segnalazione ottica d allarme 20 LIE Vap Benzina LED Verde ON Funzionamento normale LED Giallo FAULT S1 Sensore CO guasto scollegato o a fondo scala o scaduto LED Giallo FAULT S2 Sensore Vapori di Benzina guasto scollegato o a fondo scala o scaduto NOTE SUI GAS RILEVATI Il Monossido di carbonio CO un gas tossico inodore incolore leggermente pi leggero dell aria la sua densit relativa all aria 0 97 Il CO anche esplosivo ma a concentrazioni elevatissime infatti il suo LIE Limite Inferiore d Esplosivit 10 9 v v espresso in Volume II CO prodotto dalla combustione incompleta dei combustibili a base di carbonio Questi combustibili gas oli legno carbone e quelli per autoveicoli quando non bruciano correttamente si forma un eccesso di CO che diffondendosi nell ambiente respirato dalle persone dai polmon
9. model is a dual 4 20mA transmitter for Carbon monoxide CO and Petrol Gasoline vapours employing two different sensors The TS255CB is employed in gas monitoring systems for car parks The instruments comprise of a thermoplastic case in which the electronic circuit and the terminals are mounted The enclosure has downward facing cylindrical sensor housing S1 with inside a Replaceable Cartridge Sensor ZSECT for CO while the Replaceable sensor cartridge ZSK04 that contains the sensing element for Petrol Vapours is inside the sensor housing S2 placed at 130 cm from the enclosure Both cartridges have identification and calibration data The instrument has two 4 20mA linear outputs S1 with 300 ppm CO F S and S2 with 20 LEL Petrol Vapours F S These two outputs are connectable to a remote Gas Central Unit as listed in Table 1 On the front panel there are two F1 and F2 touch key using for the Test and Calibration routine protected by a code and 5 LED shows the working conditions Red LED ALARM S1 150 ppm CO alarm indication Red LED ALARM S2 20 LEL Petrol Vapours alarm indication Green LED ON normal working condition Yellow LED FAULT S1 the CO sensor should be faulty disconnected out of scale or expired Yellow LED FAULT S2 the Petrol Vap sensor should be faulty disconnected out of scale or expired NOTES ON THE DETECTED GAS Carbon monoxide CO is a colourless odourless tastel
10. occurring outside the room where it is installed or under the floor SENSOR OPERATING LIMITS Both the sensors in any case should not be exposed to temperatures lower than 40 or higher than 60 C The sensors should not be exposed to an over range concentration of 1500ppm CO and 60 LEL Petrol Vapours If this condition occurs we suggest replacing the corresponding sensor SAFETY THE CO SENSOR S1 IS AN ELECTROCHEMICAL CELL that contains a small quantity of acid It is possible that either a very strong mechanical action or an incorrect instrument use beyond the limits of its operational functioning could provoke a liquid leak out of the sensor Should this event occurs please avoid touching the come out liquid Should a contact with either the skin or eyes occur wash immediately and abundantly with water The TECNOCONTROL S r l Via Miglioli 47 SEGRATE MI Tel 02 26 92 28 90 Fax 02 21 33 734 IST 2255 CB01 01 Istruzione User s Manual Manuel d utilisation Pag 6 11 electrochemical cell employed detect CO at a very low concentration has a good resistance towards products such as sprays detergents ammonia glues and paints However in case of products containing substances in great quantity these could cause false alarms We recommend ventilating the room when products like these are used Alcohols Hydrogen and volatile organic solvents in great quantity cause false alarms and then the sensors needs one or more hours in clean ai
11. provocano la rottura del Sensore elettrochimico S1 sensori possono danneggiarsi anche se sono esposti a concentrazioni di gas molto elevate CO oltre i 1500 ppm e Vap Benzina oltre i 50 LIE In questi casi il relativo sensore deve essere sostituito ATTENZIONE IL SENSORE S1 PER CO ELETTROCHIMICO e contiene una piccola quantit d acido Nel caso avvenga una perdita dal sensore causata da un azione meccanica violenta o dall uso oltre i limiti di funzionamento evitare di toccare il liquido fuoriuscito Nel caso di contatto con pelle od occhi lavare immediatamente con abbondante acqua Interferenze con altri gas Considerare che il sensore S1 rileva CO in ambiente ad una concentrazione molto bassa In ambienti particolarmente inquinati o con vapori d altre sostanze in quantita molto elevate in particolare i solventi organici idrogeno alcoli possono avvenire falsi allarmi e il sensore deve poi rimanere molto tempo in aria pulita per riportarsi nelle condizioni di funzionamento normale 1 2 ore ATTENZIONE IL SENSORE S2 PER VAPORE DI BENZINA DI TIPO CATALITICO funziona solo alla presenza d Ossigeno non usare gas puri o l accendino direttamente sul sensore che potrebbe essere irrimediabilmente danneggiato Interferenze con altri gas Considerare che la vita utile del sensore S2 in ambienti particolarmente inquinati o con vapori di sostanze infiammabili in particolare i solventi pu ridursi notevolmente Alcune sostanze causano una rid
12. rations de v rification et de calibration et 5 LED indiquant les conditions de fonctionnement Signalisations et commandes LED Rouge ALARM S2 signal d alarme ALARM 150 ppm CO LED Rouge ALARM S1 signal d alarme ALARM 20 LIE vapeurs d essence LED Vert ON fonctionnement normal LED Jaune FAULT S1 capteur CO en panne ou d connect ou satur ou chu LED Jaune FAULT S2 capteur vapeurs d essence en panne ou d connect ou satur ou chu Touches capacitives F1 et F2 pour les op rations de v rification et calibrage CARACT RISTIQUES DES GAZ DETECTES Les donn es LIE des Gaz sous indiqu s est rapport s la norme EN 61779 1 Le Monoxyde de Carbone CO est un gaz toxique inodore sans couleur un peu plus l ger que l air Sa densit relative l air est 0 97 Il est aussi explosif mais des concentrations lev es en effet sa LIE limite inf rieure d explosivit est 10 9 v v du volume Le CO est produit par la combustion incompl te des combustibles a base de carbone et d hydrocarbures Quand ces combustibles gaz huile bois charbon et carburants pour v hicules ne br lent pas correctement il se forme un exc s de CO Lorsque le CO en se r pandant dans l ambiance est respir par les personnes par l interm diaire des poumons il atteint le sang o en se combinant avec l h moglobine il emp che le transport de l oxyg ne aux tissus et aux organes L essence e
13. yeux il est conseill de laver imm diatement avec de l eau en abondance Interf rence avec d autres gaz La cellule lectrochimique utilis e poss de une bonne r sistance aux produits d usage courant comme les a rosols ammoniaque d tersifs alcools colles ou vernis toutefois si ceux ci sont pr sents en quantit s lev es ils peuvent interf rer avec le capteur il est conseill de ventiler l ambiance apr s emploi de ces substances Consid rer qu en ambiances particuli rement pollu es par des TECNOCONTROL S r l Via Miglioli 47 SEGRATE MI Tel 02 26 92 28 90 Fax 02 21 33 734 IST 2255 CB01 01 Istruzione User s Manual Manuel d utilisation Pag 9 11 vapeurs de solvants organiques hydrog ne alcool en quantit s lev es des fausses alarmes peuvent appara tre et que le capteur devra pour retrouver ses conditions de fonctionnement normales rester longtemps en air propre ATTENTION LE CAPTEUR S2 POUR LES VAPEURS D ESSENCE EST CATHALITIQUE et fonctionne seulement en pr sence d oxyg ne Ne pas utiliser de gaz purs ou de gaz de briquet directement sur le capteur qui pourrait tre endommag irr m diablement Interf rence avec d autres gaz Consid rer qu en milieux particuli rement pollu s ou avec des vapeurs de substances inflammables pr sence de solvants la vie utile du capteur peut se r duire consid rablement Quelques substances causent une r duction permanente de sensibilit viter que le capt
14. 2 28 90 Fax 02 21 33 734 IST 2255 CB01 01 Istruzione User s Manual Manuel d utilisation Pag 4 11 se necessario dopo 2 3 ore dall installazione dopo il cambio Cartuccia o periodicamente in base alle condizioni ambientali Nota Non possibile eseguire l operazione se le uscite in mA superano S1 i 4 8 mA 15 ppm di CO oppure S2 i 12mA 10 LIE Vap Benzina o se sono accesi uno o due LED Gialli In questo caso procedere alla Calibrazione o sostituire la Cartuccia CALIBRAZIONE questa funzione permette di tarare i sensori ognuno con il proprio Codice e il rispettivo gas come indicato nel riquadro della pagina precedente AVVISO per garantire la sicurezza che non avvengano errori d elaborazione esiste la rara possibilit che durante la Calibrazione il corrispondente LED Giallo si spenga ogni 8 secondi in questo caso interrompere la procedura spegnere e riaccendere l apparecchio Ripetere la Calibrazione se la condizione persiste sar necessario inviare il rilevatore al fornitore per la riparazione Attenzione Durante la Calibrazione l uscita in mA diventer OMA La Taratura va eseguita esclusivamente in aria pulita ambiente senza la presenza di gas tossici o altri inquinanti Con i tasti eseguire il rispettivo Codice Calibrazione Il Codice per il Sensore S1 posto sulla custodia per il gas CO F2 F2 F2 F1 F2 F1 Il Codice per il Sensore S2 posto in basso per i Vapori di Benzina _ F2
15. Code d talonnage pour le capteur n 2 plac en bas du tube pour Vapeurs d essence est F2 F1 F1 F1 F2 F1 Attendre que la LED Verte et la LED Jaune correspondante s allument en feu fixe et que la LED Rouge correspondante clignote Coiffer la t te de d tection correspondant au gaz choisi avec le TC011 r gler le d bit du gaz de mani re ce que le d bitm tre indique 0 3 I min environ voir Fig 3 Attendre 2 3 minutes environ puis lorsque la LED Rouge correspondante s allume en feu fixe et pendant qu elle est ALLUM E presser la touche F2 et maintenir cette pression jusqu ce que le buzzer mette un long bip et la LED Rouge reste teinte durant au moins 2 secondes si la LED rouge continue clignoter r p ter l op ration Fermer la bouteille et ter le TC011 ce point deux cas peuvent se v rifier TECNOCONTROL S r l Via Miglioli 47 SEGRATE MI Tel 02 26 92 28 90 Fax 02 21 33 734 IST 2255 CB01 01 Istruzione User s Manual Manuel d utilisation Pag 10 11 LED Jaune et Verte allum es l talonnage a correctement t ex cut Apr s 8 secondes le d tecteur reviendra automatiquement dans les conditions de fonctionnement normal Chapitre Fonctionnement gt Pr chauffage LED Jaune allum e l talonnage a chou Dans ce cas apr s 8 secondes le d tecteur reviendra automatiquement dans les conditions de talonnage r p ter la proc dure sans r ins rer la s quence Si la cond
16. IST 2255 CB01 01 Istruzione User s Manual Manuel d utilisation Pag 1 11 IST 2255 CB01 01 T5255CB doc Trasmettitore 4 20mA di CO e Vapori di Benzina ee tel TS255CB 4 20mA Co and Petrol Gasoline vapours Gas Detector gt Sondes a transmetteurs 4 20mA pour CO et vapeurs d Essence Please read and keep this manual 4 Leggere Attentamente e Conservare questa Istruzione A Lire avec soin et garder la notice d instruction Con Cartucce Sensori Sostituibili Inside Replaceable Cartridges Sensor Avec cartouche capteur changeable Modello Model Modele Cartuccia Sensore Cartridge Sensor Cartouche Capteur TS255CB S1 CO ZS EC1 S2 Vap Benzina Pretrol Gasoline Vap Vap d essence ZS K04 Caratteristiche tecniche Technical specifications Caract ristiques techniques 12 24Vcc 10 15 3W Alimentazione Power supply Alimentation 12 24Vdc 10 15 3W 12 24Vcc 10 15 3W Gas Rilevato Detected Gas Gaz Benzina Petrol Essence Sensore Sensor Type Capteur ca talitico Electrochemical lectrochimique Catalytic Catalytique Cartuccia Sensore Cartridge Sensor Cartouche capteur Sostituibile Replaceable changeable Uscite Outputs Sortie 4 20 MA lineare Linear lin aire Resistenza di carico load resistor r sistance de charge 50 ohm 12Vdc 10 500 ohm 24Vdc 10 Campo di misura Standard Range Champ de mesure 0 20 LIE LEL Tempo di risp
17. ONAL DESCRIPTION siccciciiinziiiinninziiina nia 5 INSTALLATION uuiiai ii 5 WARNING ica iaia i 5 TES Tang CALIBRATION EE 6 DESGRIPTION iaia alan 7 CARACT RISTIQUES DES GAZ DETECTEG s ssssssssssssssssssesesssaesesssscsessescsesatscsneatsesaeansnsaeacsasansees 7 FONCTIONNEMENT i ni 7 INSTALLATION elia ia A 8 INSTRUCTIONS EE 8 VERIFICATIONS ET ETALONNAGEE ssscssssssssssssscsessesesessesesssscssssesesesaeseeseaesesaeacsnsaescsssatsceseacsesess 9 TECNOCONTROL S r l Via Miglioli 47 20090 SEGRATE Ml Tel 02 26922890 Fax 02 2133734 http www tecnocontrol it e mail info tecnocontrol it IST 2255 CB01 01 Istruzione User s Manual Manuel d utilisation Pag 2 11 CI DESCRIZIONE Il TS255CB un doppio trasmettitore 4 20mA di Monossido di carbonio CO e Vapori di Benzina con due sensori utilizzato in sistemi centralizzati d allarme per parcheggi Il rilevatore costituito da una custodia che contiene il circuito elettronico e i morsetti di collegamento Nel Portasensore S1 fissato alla custodia alloggiata la Cartuccia Sensore Sostituibile ZSECOT con l elemento sensibile a cella elettrochimica per il CO Nell altro Portasensore S2 posto in basso a 130 cm dalla custodia alloggiata la Cartuccia Sensore Sostituibile ZSKO4 con l elemento sensibile di tipo Catalitico per Vapori di Benzina Entrambe le cartucce contengono i dati identificativi
18. as With the keys perform the respective Calibration Code The Calibration Code for the Sensor 1 placed on the housing to CO gas is _ F2 F2 F2 F1 F2 F1 The Calibration Code for the Sensor 2 located below to Petrol Vapours is _ F2 F1 F1 F1 F2 F1 Wait until the respective Yellow and Green LED switch on fix and the red LED starts to flash Insert the TC011 into the respective sensor holder to regulate the influx of the gas the way that the flow meter indicates around 0 3 I mins see Fig 3 Wait around 3 minutes then when the red LED switch on and while its SWITCHED ON press the key F2 on the instrument and hold it pressed until the Red LED is switched off for at least 2 seconds and the Buzzer beeps if the Red LED continue to flash repeat the operation Then close the gas cylinder and remove TC011 At this point we can have two possibilities Yellow and Green LED illuminates the calibration routine has correctly been performed Wait 8 seconds until the instrument automatically restores the normal working conditions See Operational Description gt Preheating Yellow LED illuminates the routine has failed In this case wait 8 seconds until the instrument automatically repeat Preheating then repeat the Calibration routine without inserting again the code If condition still persists after the replacement of the Cartridge it will be necessary to send the detector back to the manufacturer for reparation
19. as air while Petrol Vap are heavier than air ELECTRICAL CONNECTION See Fig 2 the maximum distance to install each detector from the Central Unit is show in the Table 1 Normally use a four wire shielded cable The terminals S1 S2 are plug in type it is necessary to extract them to make the connection Pay attention when you insert them again being polarized IMPORTANT Once installation is completed it is necessary to adjust the sensors to the environment conditions connect the unit wait about 60 120 minutes and the carry out the Zero Ad just see Test and Calibration gt COMPATIBILITY WITH OTHER CENTRAL UNITS In case of a central unit other then Tecnocontrol please verify the max load resistor as shown in Fig 4 The max load resistor is 50 ohm with 12Vdc power supply while is 400 ohm with 24Vdc power supply We suggest using 24Vdc power supply WARNING AVERAGE LIFETIME of the sensors in clean air and in normal working condition is about 3 4 years for the CO S1 and is 5 years for the Petrol vapours S2 After this period the corresponding yellow LED flashes every 4 seconds it is necessary replacing the CO and or Petrol Vapours Cartridge Sensor PERIODICAL TESTING we advise to carry out working tests at least every year Tests Zero Adjust and Calibration with CO Nitrogen for S1 and CH Air for S2 mixture as explained on page 6 chapter Tests and Calibration Note the detector is not able to detect gas
20. d Please check the cartridge connections and compatibility see Table 3 these checks are made switching off and on the device If the condition does not change it will be necessary to replace the unit and or send it back to the supplier to repair If a Yellow and the Green LED activates 0 mA output signal this happens when the Cartridge Sensor is not working First try to perform the procedure of ZERO as described in the section Test and Calibration gt Zero adjust then disconnect and connect the unit finally try to replace a new Cartridge Sensor If the condition is not change it will be necessary to replace the unit and or send it back to the supplier to repair If the Green LED one Yellow and the corresponding Red LED activates gt 24 mA output signal this happens when the corresponding Cartridge Sensor is not working or gas concentration is out of scale higher than CO gt 375 ppm or Petrol Vap gt 23 LEL If there are not any gas leaks and the condition is not change it will be necessary to replace the unit and or send it back to the supplier to repair INSTALLATION The detector must be accurately installed according to the national dispositions in force on the safety of the plants and installation of electric devices DETECTOR POSITIONING The Fig 1 shows the instrument size The unit must be wall mounted positioned with the sensor downwards t should be fixed at 1 60 m from the floor CO gas is lighter
21. e in quanto l unico metodo sicuro per controllare l effettivo funzionamento dei sensori La Verifica va eseguita utilizzando il rispettivo gas come indicato nella pagina precedente Per il Sensore S1 per gas CO non serve inserire il codice applicare direttamente il gas Per il Sensore S2 per i Vap Benzina prima di applicare il gas esequire il Codice _ F2 F1 F2 F1 Dopo aver inserito il codice Il Led Giallo S2 per i Vap di Benzina comincia a lampeggiare Infilare il TC011 sul corrispondente portasensore regolare il riduttore della Bombola in modo che il flussometro indichi circa 0 3 l min vedi fig 3 Controllare che il multimetro con i puntali sui Test Point TP1 S1 vedi Fig 2 raggiunga in 2 3 minuti per S1 CO i 190 210 mV ovvero che l uscita in mA aumenti fino a circa 20 mA e la centrale cui collegato il Trasmettitore indichi circa 300ppm 20 mentre sui Test Point TP2 S1 per S2 Vap Benzina i 190 210 mV ovvero che l uscita in mA aumenti fino a circa 20 mA e la centrale cui collegato il Trasmettitore indichi circa 20 LIE 2 Se il valore molto diverso opportuno effettuare la Calibrazione Terminata la Verifica chiudere la bombola togliere il TC011 Nel caso del sensore S2 Vap Benzina premere il tasto F2 per concludere la verifica ed accertarsi che il Led Giallo rimanga spento Attendere 3 5 minuti per tornare alle condizioni di funzionamento normale DESCRIPTION The TS255CB
22. er this period the two yellow LED lights off the green LED ON illuminates to indicate normal functioning After this period the unit is able to detect gasses even if it attains the optimum stability conditions after about 4 hours continual functioning NORMAL OPERATION the green LED ON should be light on The Red LED ALARM S1 illuminates when CO concentration attains 150 ppm The Red LED ALARM 82 illuminates when Petrol Vapours concentration attains 10 LIE FAULTS the instrument signal different kind of failures as listed below The Yellow LED FAULT S1 or FAULT S2 illuminates and the S1 CO output or S2 Petrol Vapours Output falls down to 0 MA If a Yellow LED illuminates each 4 seconds with Green LED activate this happens when the corresponding Cartridge Sensor has exceeded its theoretical period of life and its correct operation is not longer guaranteed The detector keeps on operating normally but it is necessary to replace as soon as possible the corresponding Cartridge Sensor with a new one The type to be required is described at Page 1 The replacement procedure is described in the attached manual If a Yellow LED activate and Green LED is off 0 mA output signal this signal different kind of faults 1 The corresponding Cartridge Sensor is not working please replace with new one 2 If a new Cartridge Sensor is installed or it is not correctly connected or a not compatible one is mounte
23. es le buzzer mette trois bips et la s quence est effac e automatiquement KIT D ETALONNAGE TECNOCONTROL TC011 ET BOUTEILLE AVE MELANGE DE GAZ TITRE pour V rification et Etalonnage Le m lange utiliser est CO 300ppm en azote et M thane 0 44 v v 20 LIE en air Il est possible d utiliser soit les bouteilles jetables avec robinet de sortie gaz soit celles la haute pression avec d tendeur Utiliser le Kit d talonnage Tecnocontrol TC011 TEST ELECTRIQUE Code Test F2 F2 F1 F1 cette fonction permet d effectuer un test fonctionnel de l appareillage Apr s avoir mis l installation en s curit et avoir ins r le Code Test toutes les LED s teignent Ils s allumeront ensuite en s quence de la LED jaune jusqu la rouge la fin toutes les LED resteront allum es pendant environ 5 secondes puis le d tecteur reviendra dans les conditions de fonctionnement normal Il est souhaitable d ex cuter cette op ration tous les 6 12 mois en fonction de l utilisation Les deux sorties 4 20mA restent invari es Remarque n est pas possible d ex cuter l op ration si une ou les deux LED Rouges sont allum s R GLAGE DU ZERO Code du Z ro F2 F1 F1 F2 cette fonction sert pour r gler le z ro du capteur simultan ment et doit tre effectu e exclusivement en air propre milieu sans pr sence de gaz polluants inflammables ou autres Apr s avoir ins r le Code du Z ro comme confirmation de l op ration 1
24. ess poisonous gas slightly lighter than air its density has to air is 0 97 is explosive but to very high concentrations in fact it s LEL Lower Explosion Limit 10 9 v v expressed in Volume CO is produced by incomplete burning of carbon based fuels including gas oil wood coal and car fuels TECNOCONTROL S r l Via Miglioli 47 SEGRATE MI Tel 02 26 92 28 90 Fax 02 21 33 734 IST 2255 CB01 01 Istruzione User s Manual Manuel d utilisation Pag 5 11 When a fuel does not burn properly an excess of CO is produced which is poisonous When CO enters the body it prevents the blood from bringing oxygen to cells tissues and organs Petrol Gasoline is a liquid mixture of paraffin hydrocarbons hexane and octane in proportion very varying and other additives The Petrol Gasoline is volatile and produces extremely inflammable vapours is heavier than air middly it has density relative to the air of 2 8 and its LEL is around 1 2 v v express in Volume OPERATIONAL DESCRIPTION The two electrochemical sensors are temperature compensated but are sensitive to extreme humidity variations The calibration is carried out with CO gas and for Petrol Vapours Anyway it can contemporaneously detect other gases that should be present in the same environment as listed in table 4 PREHEATING when powered both the sensors needs a time of preliminary heating of about 60 seconds During this period the two yellow LED FAULT flashes Aft
25. eur vienne au contact avec des vapeurs de Silicone pr sent en peintures et colles T tra thyle de Plomb ou phosphates Les autres substances causant une perte temporaire de sensibilit sont les halog nes l hydrog ne sulfur le chlore les hydrocarbures chlor s trichlor thyl ne ou t trachlorures de carbone Apr s une br ve p riode en air propre le capteur reprend son fonctionnement normal V RIFICATIONS ET ETALONNAGE REMARQUE IMPORTANTE Toutes les op rations suivantes doivent tre ex cut es seulement par un personnel comp tent et form tant donn que durant ces op rations les sorties relais fonctionneront en provoquant l activation des asservissements qui leurs sont connect s Le TS255CB poss de trois diff rentes fonctions prot g es par un Code TEST LECTRIQUE REGLAGE DU ZERO TALONNAGE ET VERIFICATION DU TALONNAGE pour le CO S1 Pour acc der ces fonctions il est n cessaire d ins rer le Code en utilisant les touches F1 et F2 Les deux boutons sont tactiles Pour que la pression sur une touche soit reconnue appuyer la pointe d un doigt sur le bouton et la tenir press e durant environ une seconde jusqu ce que s teigne un bref instant la LED Verte et que le buzzer mette un bip pour F1 et deux bips pour F2 Ensuite l on peut passer au bouton suivant Puis le buzzer met un long bip pour confirmer la validit du code ins r En cas d erreur il suffit d attendre environ 10 second
26. i raggiunge il sangue dove impedisce il trasporto dell ossigeno ai tessuti e agli organi La Benzina un liquido composto di una miscela d idrocarburi paraffinici esano e ottano in proporzione molto variabile e da additivi La Benzina volatile e forma dei vapori estremamente infiammabili che sono pi pesanti dell aria mediamente hanno densit relativa all aria di 2 8 mentre il loro LIE circa 1 2 v v espresso in Volume FUNZIONAMENTO due sensori utilizzati sono compensati in temperatura ma sono sensibili alle variazioni d umidit estreme La taratura eseguita con gas CO e per Vapori di Benzina ma in grado di rilevare anche altri gas se presenti nello stesso locale come indicato in Tabella 2 PRERISCALDO quando il trasmettitore alimentato inizia la fase di stabilizzazione dei due sensori segnalata dal lampeggio dei due LED gialli FAULT Dopo circa 60 secondi i LED gialli si spengono e si accende il LED verde ON che indica il normale funzionamento Dopo questo tempo entrambi i sensori sono in grado di rilevare gas ma raggiungono le condizioni di stabilit ottimali dopo circa 4 ore di funzionamento continuo FUNZIONAMENTO NORMALE deve essere acceso il solo LED Verde ON II LED Rosso ALARM S1 si accende se la concentrazione di Gas CO S1 supera i 150 ppm II LED Rosso ALARM S2 si accende se la concentrazione di Vap Benzina S2 supera il 20 LIE I GUASTI possibili sotto elencati sono i
27. ition persiste m me apr s la substitution de la Cartouche Capteur il sera n cessaire d envoyer le d tecteur au fournisseur pour r paration VERIFICATION du Etalonnage code non n cessaire pour S1 CO la v rification du fonctionnement correct du d tecteur doit tre ex cut apr s l Etalonnage ou apr s l installation ou pendant les entretiens p riodiques tant donn qu il s agit de la seule m thode permettant de contr ler la fonction effective du d tecteur La V rification s ex cute en utilisant le gaz respectif comme indiqu la page pr c dente Le Code de VERIFICATION pour le capteur n 1 plac directement sous le bo tier pour CO est non n cessaire Le Code de VERIFICATION pour le capteur n 2 plac en bas du tube pour Vapeurs d essence est _ F2 F1 F2 F1 Enfiler le TC011 sur la t te de d tection correspondante et le bloquer avec la vis molet e r gler le d bit du gaz de fa on ce que le d bitm tre indique 0 3 I min environ Fig 3 et contr ler avec le voltm tre le valeur en mV sur les bornes de test Fig 2 Pour le CO v rifiez que la valeur sur TP1 et S1 entre 190 et 210 mV est atteinte Ou bien que la sortie en mA augmente jusqu 20 mA environ et que la centrale laquelle le d tecteur est connect indique 300 ppm CO 20 Pour les Vapeurs d essence v rifiez que la valeur sur TP2 et S2 entre 190 et 210 mV est atteinte Ou bien que la sortie en mA augmente jusqu 20 mA envir
28. librate the sensor see Calibration Then close the gas bottle remove TC011 The mA output will slowly decrease up to 4 mA normal working conditions CE DESCRIPTION Le TS255CB est une sonde deux capteurs et deux transmetteurs 4 20mA pour la d tection simultan e du monoxyde de carbone CO et du Vapeurs d essence Le mod le TS255CB est utilis en syst mes centralis s d alarme pour parkings souterrains tunnels routiers et environnements devant tre prot g s de la pr sence de CO et vapeurs d essence Le d tecteur est constitu par un bo tier contenant le circuit lectronique et les borniers de raccordement dans la porte capteur plac dans la partie inf rieure du bo tier est log e une cartouche capteur changeable ZSEC1 contenant l l ment sensible pour le CO cependant que dans le porte capteur situ en partie basse 130 cm sous le bo tier est log e une cartouche capteur changeable ZSK04 contenant l l ment sensible pour les vapeurs d essence Les deux cartouches poss dent les donn es identificatrices et de r glage Le TS255CB poss de deux signaux de sortie 4 20mA lin aire avec fin d chelle 300 ppm partie par million pour le CO S1 et de 20 LIE Limite Inf rieur d explosivit pour les vapeurs d essence S2 Il s utilise en se raccordant sur les centrales d alarmes mono et multivoies Tecnocontrol Sur le couvercle se trouvent les touches de codage F1 et F2 pour les op
29. lizzata Il morsetto S1 S2 ad innesto ed necessario sfilarlo per effettuare i collegamenti Prestare attenzione nel reinserirlo dato che polarizzato IMPORTANTE terminata l installazione per adattare i sensori alle condizioni ambientali alimentare l apparecchio attendere circa 60 120 minuti e poi eseguire la Regolazione dello Zero vedi Verifiche e Calibrazione COMPATIBILIT CON LE ALTRE CENTRALI Se non si usa una Centrale Gas Tecnocontrol calcolare la resistenza di carico massima utilizzando il grafico in fig 4 La resistenza di carico massima con alimentazione 12Vcc 50 ohm mentre con 24Vcc 400 ohm Si consiglia di utilizzare un alimentazione a 24Vcc AVVERTENZE LA VITA UTILE DEI SENSORI in aria pulita mediamente di 3 4 anni per il CO S1 mentre di 5 anni per quello per Vapori di Benzina S2 Al termine di questo periodo indicato dallo strumento con un ampeggio del corrispondente LED Giallo ogni 4 secondi necessario sostituire la Cartuccia Sensore VERIFICHE PERIODICHE necessario eseguire almeno ogni anno la verifica di funzionamento Test Elettrico Regolazione dello Zero e Verifica Calibrazione con la miscela CO Azoto S1 e CHy Aria 52 vedi sotto Verifiche e Calibrazione NOTA Il rilevatore non in grado di rivelare presenza di gas fuori del locale in cui installato o sotto il pavimento LIMITI DI FUNZIONAMENTO Temperature inferiori a 40 C e superiori a 60 C
30. mA indication de la panne probable de la Cartouche Capteur correspondante Essayer tout d abord le R glage du ZERO comme d crit dans la rubrique V rification et Etalonnage puis ex cutez le contr le en coupant et en r tablissant l alimentation du d tecteur En cas de persistance remplacer la Cartouche Capteur correspondante Si malgr cela la condition persiste il sera n cessaire de remplacer et ou renvoyer le d tecteur au fournisseur pour r paration Si la LED Verte une des LED Rouges et une des LED Jaunes sont allum es tous les relais activ s et sortie gt 24mA indication de ou panne de la Cartouche Capteur correspondante ou une concentration de gaz sup rieur au fond d chelle C0 gt 375 ppm ou vap d essence gt 23 LIE S il n est pas constat de fuite de gaz et que la condition perdure apr s la substitution de la Cartouche Capteur il sera n cessaire d envoyer le d tecteur au fournisseur pour r paration INSTALLATION Les d tecteurs doivent tre install s et positionn s en suivant toutes les r gles nationales en vigueur pour les installations lectriques et les normes de s curit des installations MONTAGE en Fig 1 sont indiqu es les dimensions Le d tecteur doit tre mont en saillie murale avec le capteur tourn vers le bas POSITIONNEMENT le bo tier contenant l lectronique et le capteur de CO doit tre fix a environ 160 cm du sol et apr s avoir d pli le tube articul celui ci doit
31. mentation Fig 4 Alimentazione Resistenza di Carico 4 20mA Power supply Load resistance diagram 4 20mA Alimentation R sistance de charge 4 20mA
32. n moyenne pour le capteur des Vapeurs d essence S2 Au terme de cette p riode indiqu par l instrument l aide d un clignotement toutes les 4 secondes des LED Jaunes correspondant il est n cessaire de remplacer la Cartouche Capteur correspondant VERIFICATIONS PERIODIQUES est n cessaire d ex cuter tous les ans la v rification de fonctionnement du d tecteur Test lectrique R glage du Z ro et V rification et Etalonnage avec un m lange CO azote et CHyAir voir section V rifications et Etalonnage REMARQUE Le d tecteur n est pas apte d tecter le CO et les Vapeurs d essence hors de l ambiance dans laquelle il est install ou sous un plancher ou lieu confin LIMITES DE FONCTIONNEMENT des temp ratures inf rieures a 40 C et sup rieures a 60 C provoquent la d t rioration du capteur lectrolytique S1 Les capteurs peuvent galement tre endommag s s ils sont expos s des concentrations tr s lev es de gaz 1500ppm CO ou 60 LIE Vapeurs d essence Dans ce cas la Cartouche Capteur correspondante doit tre remplac e ATTENTION LE CAPTEUR S1 POUR CO EST ELECTROCHIMIQUE et contiennent une petite quantit d acide sulfurique qui est corrosif Normalement il ne doit y avoir aucune perte au capteur dans le cas contraire ceci est du une action m canique violente ou un usage outre limites de fonctionnement Dans le cas d un contact accidentel entre du liquide provenant du capteur et la peau ou les
33. ndicati dall accensione del LED giallo FAULT S1 o FAULT S2 e portando la corrispondente uscita S1 per il CO e S2 per Vap Benzina a OmA Se un LED Giallo si accende ogni 4 secondi con il LED Verde acceso avvisa che la corrispondente Cartuccia Sensore ha superato il suo limite teorico di vita e non pi garantito il corretto funzionamento Il rilevatore continua a funzionare normalmente ma necessario sostituire la corrispondente Cartuccia con una nuova il tipo da richiedere indicato a pag 1 La procedura di sostituzione descritta nella documentazione ad essa allegata Se un LED Giallo acceso e il Verde spento uscita 0mA indica pi possibilit di guasto 1 la corrispondente Cartuccia Sensore guasta e va sostituita 2 se installata una Cartuccia nuova o non collegata correttamente o non stata montata quella compatibile Controllare le connessioni con la cartuccia e la compatibilit vedi a pag 1 Eseguite le verifiche spegnere e riaccendere l apparecchio Se la condizione persiste sar necessario sostituire e o inviare il rilevatore al fornitore per la riparazione Se un LED Giallo e il Verde sono accesi uscita 0mA probabilmente guasta la corrispondente Cartuccia Sensore Prima provare ad eseguire la Regolazione dello ZERO vedi la sezione Verifiche e Calibrazione poi spegnere e riaccendere l apparecchio ed infine provare a sostituire la corrisponden
34. on et que la centrale a laquelle le d tecteur est connect indique 20 LIE 2 Dans le cas de r sultats diff rents il faut refaire l talonnage Une fois termin la V rification ter le TC011 Attendre 3 5 minutes environ le d tecteur reviendra aux conditions de fonctionnement normal Apres cela la sortie reviens progressivement 4 mA Tabella 1 Table 1 Tableau 1 Sezione Cavo Resistenza Cavo La max distanza cui pu essere instal La max distanza cui pu essere installato ogni Singolo Conduttore lato ogni trasmettitore dalla centralina trasmettitore dalla centrali Modello Cable Size Cable Resistance Tecnocontrol Modello ID250 e SE148 CE100 CE400 CE600 CE700 CE380UR Single wire the maximum distance to install each de Tthe max distance to install each detector from the Section du cable R sistance cable tector from the Gas Central Unit Model Gas Central Unit Model par conducteur 1D250 and SE148 is CE100 CE400 CE600 CE700 CE380UR is La maxi distance laquelle peuvent tre La maxi distance laquelle peuvent tre raccor raccord es les sondes les centrales d es les sondes les centrales CE100 CE400 1D250 et SE 148 est CE600 CE700 CE380UR est 0 75 mm 26 on 00m 8m 1 mm 20 on 150m Om 15 mm 14 okm Lamm oo S 25 mm 8 on 400m aam Tabella 2 Interferenze con altri Gas Table 2 Typical cross Sensitivities Tableau 2 Interf rence
35. on is used to manually adjust the Zero of both sensors and can be done in clean air only environment without the presence of toxic gas or other pollutants Immediately after having inserted the Zero Code as a confirmation of the operation carried out there will be 1 flash of the two red LED and both the outputs will become 4 0 mA We suggest performing this operation after the installation or after the change of the cartridge and periodically based on the environmental conditions Note This function is not working if mA output S1 is more than 4 8 mA 15 ppm CO or S2 is more than 12mA 10 LEL Petrol Vapours and or one or both Red LED are already been switched on In this case it will be necessary to recalibrate the unit and or replacing the corresponding Cartridge CALIBRATION this function allows completely recalibrate the sensors everyone with their own code and gas as explain up in the box Warning to guarantee that no errors of elaboration happen the possibility exists that during the Calibration the corresponding yellow LED switch off every 8 seconds in this case interrupt the procedure switch off and switch on the instrument and repeat the Calibration If condition persists it will be necessary to send the detector to the supplier for the reparation Important note during Calibration routine the mA output is OMA The Calibration can be done in clean air only environment without the presence oftoxic or other polluting g
36. orties S1 pour le CO et S2 pour les vapeurs d essence OmA TECNOCONTROL S r l Via Miglioli 47 SEGRATE MI Tel 02 26 92 28 90 Fax 02 21 33 734 IST 2255 CB01 01 Istruzione User s Manual Manuel d utilisation Pag 8 11 Si une des LED Jaune clignote toute les 4 secondes avec la LED Vert allum e avertissement que la Cartouche Capteur correspondante a d pass sa limite de vie et que le fonctionnement correct n est plus garanti Le d tecteur continue fonctionner normalement mais il est n cessaire au plus t t de remplacer la Cartouche Capteur concern e par une nouvelle le type commander est indiqu en Page 1 La proc dure de substitution est d crite dans la documentation jointe la Cartouche Capteur Si une des LED Jaune est allum e et la Vert est teint sortie 0mA indication de plusieurs possibilit s de d rangement c est dire 1 la Cartouche Capteur correspondante est en panne la remplacer par une nouvelle 2 si une nouvelle Cartouche Capteur est install e ou bien elle n est pas correctement connect e ou bien elle n est pas compatible Contr ler les connexions avec la Cartouche Capteur et la compatibilit Voire page 1 Ex cutez le contr le en coupant et en r tablissant l alimentation du d tecteur Si la condition perdure il sera n cessaire de remplacer et ou de renvoyer le d tecteur au fournisseur pour r paration Si une des LED Jaunes et la Verte sont allum es sortie 0
37. osta T Response Time Tg Temps de r ponse To s60 a tata d Ripetibilit Repeatability R p titivit lt 5 segnale signal Precisione Accuracy Precision 10 Deriva a lungo termine Long time drift D rive a long terme lt 4 anno year an Limite Funzionamento Sensore Sensor limits Limite chelle 30 LIE LEL Vita media in aria pulita Average Life in fresh air Vie moyenne en air pur 5 anni years ans Temp umidit di funzionamento Operation Temp Humidity 20 50 C 15 90 RH Temp rature et hygrom trie de fonctionnement non condensata non condensed non condens e Pressione di funzionamento Atmosferica 10 Operation Pressure Pression de fonctionnement Atmospherict10 Atmosph rique 10 Tempo massimo di immagazzinamento Max Storage Time Temps maximum de stockage 3 mesi 2 month 3 mors Temperatura Umidit di immagazzinamento 0 20 C 5 95 RH Storage Temp Humidity Temp rature et hygrom trie de stockage non condensata non condensed non condens e Grado di protezione IP Code Indice de protection IP65 Resistenza agli urti Mechanical strength R sistance aux chocs 4 Joule Dimensioni Size Dimensions du bo tier 17 5 x 7 x 166 5 cm CI E 2 NOTE SUI GAS RILEVATI lai 2 FUNZIONAMENTO 2 INSTALLAZIONE iii iii 2 NAH Ka i 3 VERIFIGHE E GALIBRAZIONE uul ei ai 3 DESCRIPTION amener 4 NOTES ONTHE DETEGCTED GAS ucli alia 4 OPERATI
38. r to recover the normal sensitivity conditions SAFETY THE PETROL VAP SENSOR S2 IS A CATALYTIC SENSOR that operates only in presence of Oxygen Do not use pure gases or a lighter directly on the sensor since they could damage it irremediably Consider that the sensor life can be reduced in polluted environments or with flammable vapours especially solvents and in great quantity can cause false alarms Some substances cause a permanent reduction in sensitivity Avoid contacts of the sensor with vapours of Silicone compounds Tetra ethyl Lead petrol antiknock additive and Phosphate esters since they can reduce irremediably its sensitivity Some substances produce a temporary loss of sensitivity This inhibitors include Hydrogen sulphides Chlorine Chlorinated hydrocarbons and halogenated compounds The sensitivity is recovered after a short period of running in clear air TEST and CALIBRATION PAY ATTENTION This procedure has to be made with attention by authorized and trained people starting this procedure it will increase mA Outputs causing the activation of connected alarm devices to the Gas Central Unit OPERATION CHECK ZERO ADJUST CALIBRATION AND CALIBRATION CHECKS only for sensor S1 are different code protected functions To access these functions is necessary to insert the relevant Code through the keys F1 and F2 These two buttons are touching sensitive to enable the procedure touch the key with the tip of a finger To
39. rifica le miscele da utilizzare sono Gas CO a 300 ppm in Azoto e Metano a 0 44 v v 20 LIE in Aria E possibile usare sia le bombole monouso con valvola d erogazione sia le ricaricabili ad alta pressione con riduttore di pressione Inoltre necessario il kit di calibrazione Tecnocontrol TC011 TEST ELETTRICO Codice Test F2 F2 F1 F1 questa funzione permette di effettuare un test funzionale dell apparecchiatura Dopo aver messo l impianto in sicurezza ed aver inserito il Codice Test si spengono tutti LED Quindi si accenderanno in sequenza tutti i LED dal Giallo fino al Rosso Le due uscite 4 20mA rimangono invariate Alla fine tutti i LED rimarranno accesi per circa 5 secondi poi la centralina torner nelle condizioni di funzionamento normale consigliabile eseguire quest operazione ogni 6 12 mesi in base all utilizzo Nota Non possibile eseguire l operazione se uno o entrambi i LED Rossi sono accesi REGOLAZIONE DELLO ZERO Codice di Zero F2 F1 F1 F2 questa funzione serve per regolare manualmente e contemporaneamente i sensori a Zero e va effettuata esclusivamente in aria pulita ambiente senza la presenza di gas tossici o altri inquinanti Dopo aver inserito il Codice di Zero a conferma dell avvenuta operazione avverr 1 lampeggio dei 2 LED Rossi e le uscite diventeranno 4 0 mA Si consiglia di eseguire quest operazione TECNOCONTROL S r l Via Miglioli 47 SEGRATE MI Tel 02 26 9
40. st un liquide compos d un m lange d hydrocarbures paraffiniques hexane et l octane en proportion varie et les additifs L essence est extr mement inflammable et volatile sous forme des vapeurs qui constituent un gaz plus lourd de l air sa densit relative l air est 2 8 et sa LIE est 1 2 v v exprim en Volume FONCTIONNEMENT Les deux capteur sont compens en temp rature mais restent sensibles aux variations extr mes d humidit L talonnage est effectu pour le CO et les vapeurs d essence mais en m me temps l on peut d tecter d autres gaz pr sents dans la m me pi ce comme indiqu s en Tableau 2 PR CHAUFFAGE a partir de la mise sous tension la sonde commence la phase de pr chauffage du capteurs signal e par le clignotement des deux LED jaune FAULT Apr s environ 60 secondes les LED jaunes s teignent et la LED verte ON s allume indiquant le fonctionnement normal Apr s ce temps le capteur est apte d tecter le gaz mais il n atteint les conditions de stabilit optimale qu apr s 4 heures environ de fonctionnement continu FONCTIONNEMENT NORMAL le seul LED Vert ON doit tre allum Le LED Rouge ALARM S1 s allume si la concentration de CO S1 d passe 150 ppm Le LED Rouge ALARM S2 s allume si la concentration des vapeurs d essence d passe 20 LIE DERANGEMENT La centrale signale les anomalies ci dessous d crites en allumant la LED jaune correspondante FAULT S1 ou S2 en portant les s
41. te Cartuccia Se la condizione persiste sar necessario sostituire e o inviare il rilevatore al fornitore per la riparazione Se acceso il LED Verde un Rosso e il relativo Giallo uscita gt 24 0mA indica o il guasto della corrispondente Cartuccia oppure una concentrazione di gas superiore al F S CO gt 375 ppm o Vap Benzina gt 23 LIE Se non presente alcuna fuga di gas e la condizione persiste anche dopo la sostituzione della Cartuccia sar necessario inviare il rilevatore al fornitore per la riparazione INSTALLAZIONE Trasmettitori vanno installati e posizionati seguendo tutte le norme nazionali vigenti per gli impianti elettrici e le norme di sicurezza degli impianti TECNOCONTROL S r l Via Miglioli 47 SEGRATE MI Tel 02 26 92 28 90 Fax 02 21 33 734 IST 2255 CB01 01 Istruzione User s Manual Manuel d utilisation Pag 3 11 POSIZIONE in fig 1 sono indicate le dimensioni Il trasmettitore va installato a parete con i sensori rivolti verso il basso e va fissato a circa 1 60 m dal pavimento il gas CO leggermente pi leggero dell aria mentre i Vapori di Benzina sono pi pesanti dell aria COLLEGAMENTI ELETTRICI fig 2 Va utilizzato un cavo schermato a 4 conduttori La calza va collegata a massa solo dal lato Centrale La distanza massima cui pu essere installato ogni rivelatore dalla centrale indicato nella Tabella 1 in funzione della sezione del cavo utilizzato e della Centrale Gas uti
42. uzione permanente di sensibilit evitare che il sensore venga a contatto con vapori di Silicone presente in vernici e sigillanti Tetraetile di Piombo o Esteri fosfati Altre sostanze causano una temporanea perdita di sensibilit questi inibitori sono gli Alogeni l Idrogeno solforato il Cloro e gli Idrocarburi clorurati Trielina o Tetracloruro di carbonio Dopo un breve tempo in aria pulita il sensore riprende il proprio funzionamento normale VERIFICHE E CALIBRAZIONE NOTA IMPORTANTE le seguenti operazioni vanno eseguite solo da personale esperto e addestrato in quanto le uscite in mA cambiando valore provocano l attivazione dei dispositivi d allarme della Centrale cui sono collegate TEST ELETTRICO REGOLAZIONE DELLO ZERO E CALIBRAZIONE E VERIFICA solo per 52 Vap Benzina per eseguire queste funzioni necessario inserire il relativo Codice tramite i pulsanti F1 e F2 due Pulsanti sono a sfioramento per attivarne il funzionamento appoggiare la punta del dito e tenerla per circa un secondo finche non si spegne per un attimo il LED Verde e il cicalino emette un Bip per F1 e due Bip per F2 Dopodich si pu passare al pulsante successivo Poi il Cicalino emette in lungo Bip per confermare la validit del codice inserito In caso d errore basta aspettare circa 10 secondi e la sequenza segnalata da tre Bip cancellata KIT DI TARATURA E BOMBOLE CON MISCELA GAS sia per la Calibrazione sia per la Ve