Home
        ELMON classic 41-312 ELMON classic 41-812
         Contents
1.             Logic                               i Go    OUT  100   REL1                                                    Functional circuit diagram    16    ELMON classic 41 312   ELMON classic 41 812  Safety Relais    4  Intended use    The switching device can only fulfill its safety relevant task  if it is used as intended within specifications     The intended use of the switching device is the use as a protection system in connection with safety contact  mats  safety bumpers and safety contact edges with 8 2 kO resistance for steady state current monitoring     A different use or any use going beyond the intended use is not within specifications  The manufacturer  does not accept any liability for any damage arising from use not within specifications     Any use for special applications requires prior release by the manufacturer     5  Application example                            Safety orientated monitoring of a safety contact strip with start release via release pushbutton and separate  continuation of the control circuits  category 3 compliant application according to EN ISO 13849 1      In order to check the functionality of the load breaking K1 and K2 relays the break contacts of these contactors  are integrated into the start circuit  RESET      The signaling relay output is used to visualize the switching state of the safety contact edge   Circuit diagram in voltage free state  Sensor not operated    1 Sensor  edge  mat or bumper    2 Release key    17        
2.        Housing    Dimensions  HxWxD   Housing  Housing incl  cable clamps    Protection type  with M16 cable clamps  with M16 blanking plug    Protection class  Contamination degree  Overvoltage category  Rated insulation voltage    Rated impulse voltage resistance    Weight  Temperature range    Connection cable cross section    Certifications    ELMON classic 41 312  41 812     AC 15  230V AC  1A  550000 Op      DC 13  30V DC  3A  120000 Op     to the operation of the sensor     ABS  transparent lid   polycarbonate        3 Sek     With the RLU version the signal relay switches synchronously    120       120 x 80 x 56 mm  120 x 102 x 56 mm    IP65    Ul   250V   4 00 kV   350g    20   C to  55   C  single  or fine stranded cable  0 75 1 5 mm     EN ISO 13849 1 2008 Category 3 PL e   MTTFd 236 years  DC 99     EN 62061 2013 SILCL 3   PFHd 8 59E 09 1 h        Electronics    MTTFd 625 years  DC 99         Electromechanics    EC type examination no     44 205 13176203      Certificate no      B10d 2000000  MTTFd 380 years  DC 99   Nop 52560           Test report no      44 780 13 xxxxxx 3512 6372             14  EC declaration of conformity  We hereby declare that the following products of the series     ELMON rail 41 312   article number 1114 0060  format serial number yymmnnnnn     ELMON rail 41 812   article number 1114 0130  format serial number yymmnnnnn     Safety switching device for the combination of switching strips  switching mats and  switching bumpers for avoiding 
3.    55   C  Section des c  bles c  ble monobrin ou    brins fins  0 75 1 5 mm     Homologations    ELMON classic 41 312  41 812  EN ISO 13849 1 2008 cat  gorie 3 PL e   MTTFd 236 ann  es  DC 99     EN 62061 2013 SILCL 3   PFHd 8 59E 09 1 h                        de    Electronique MTTFd 625 ann  es  DC 99         TUV NORD    T  V NORD CERT  GmbH    B10d 2000000  MTTFd 380 ann  es  DC 99   Nop 52560     Electrom  canique          Certificat d examen Certificat n    Rapport de test n     CE de mod  le type n    44 780 13 xxxxxx 3512 6372  44 205 13176203    34    ELMON classic 41 312   ELMON classic 41 812  Relais de s  curit      14 D  claration de conformit   CE  Par la pr  sente  nous d  clarons que les produits mentionn  s ci dessous de la gamme     ELMON rail 41 312   Num  ro d article 1114 0060  Format Num  ro de s  rie yymmnnnnn     ELMON rail 41 812   Num  ro d article 1114 0130  Format Num  ro de s  rie yymmnnnnn     appareil de commutation s  curis   en combinaison avec des barres de commutation   des tapis de commutation et des pare chocs pour   viter les dangers aux points de coin   cement et de cisaillement sur la base de la conception et du mode de fabrication ainsi  que dans un mod  le que nous avons mis nous m  me en circulation correspond aux  exigences de s  curit   et de sant   relatives des directives de la CEE suivantes     Directive machines 2006 42 CEE  EN ISO 13849 1 2008   EN ISO 13849 2 2013   EN 62061 2013 09   EN 60947 5 1 2010 04   EN 61000 6 2 2005 
4.    Das Ger  t kann in Haushaltsumgebung und Industrieumgebung bis zu einer H  he von 2000m  A   ber NN verwendet werden  Das Ger  t darf nicht in Bereichen mit starken Temperaturwechseln    betrieben werden              pce mec es uo  Ho 13 ELMON classic 41 312  230 V AC  TO 14  ELMON classic 41 812  115 V AC     DIL Switch       i   fo 11  Manual 79 I Reset  lo12 24 V AC DC  Reset Mode    80                                        Los  TT OUT     REL1                                      U Op                948 rel    e c                                        O2                      Sensor                    logic                   03  i ECH i OUT  100 H REL1    04                                                                   Funktionsschaltbild    4  Bestimmungsgem    e Verwendung  Das Schaltger  t kann seine sicherheitsrelevante Aufgabe nur erf  llen  wenn es bestimmungsgem  f eingesetzt  wird     Die bestimmungsgem    e Verwendung des Schaltger  tes ist der Einsatz als Schutzeinrichtung in Verbindung  mit Sicherheitskontaktmatten  Sicherheitsbumpern und Sicherheitskontaktleisten mit 8 2 kO Widerstand  zur Ruhestrom  berwachung     Ein anderer oder dar  ber hinausgehender Einsatz ist nicht bestimmungsgem      F  r Sch  den  die aus nicht  bestimmungsgem    en Verwendungen entstehen    bernimmt der Hersteller keine Haftung     Der Einsatz bei Sonderanwendungen bedarf einer Freigabe vom Hersteller     5  Anwendungsbeispiele                            Sicherheitsgerichtet
5.    LED AUX  jaune   Sortie de signalisation allumee          S il n y a pas de message d erreur  l   tat de marche est montr   via la LED Power  S il y a un message d erreur   le nombre d impulsions indique l erreur     Impulsion   Message d erreur    Alimentation en courant en dehors de la zone de valeur valide       Erreur lors du test de l entr  e du signal       Commande de sortie du relais en panne          Transfert de donn  es entre microcontr  leurs en panne       6 3 Bornes de connexion    L1N    ELMON classic 41 312  tension d alimentation 230 V 50 60 Hz  ELMON classic 41 812  tension d alimentation 115 V 50 60 Hz       24V AC DC    tension d alimentation 24 V CA CC       Connexion   metteur de signal       Contact de connexion relais de s  curit   1    Contact de connexion relais de s  curit   2       Contact de connexion relais de signal          Connexion manuelle r  initialisation red  marrage  touche NO  en option        29    6 4 Commutateur DIP pour r  glage mode de fonctionnement    S1  AUX       ON     r  initialisation automatique      OFF     enclenchement erreur   r  initialisation manuelle  r  glage d usine   S2  Reset        ON     mode sortie de signalisation AUX  RLU     OFF     mode sortie de signalisation AUX  RL  r  glage d usine     7  Modes de fonctionnement    7 1 Sortie de s  curit      Utilisation s  par  e ou combin  e du circuit de commande  poursuite redondante des contacts de commu   tation   Pour utiliser ensemble les contacts de commuta
6.    tat de surveillance du g  n  rateur de signal et la tension de travail   tablie sont affich  s par LED    Quand il y a un message d erreur  toutes les sorties de s  curit   sont inactives     L appareil peut   tre utilis   dans un foyer et en milieu industriel jusqu    une hauteur de 2000m via  NN  L appareil ne peut pas   tre utilis   dans des zones    forte temp  rature           Lo13 ELMON classic 41 312  230 V AC   0 14  ELMON classic 41 812  115 V AC                 DIL Switch O11    012          24 V AC DC          Manual 79    Reset     Reset Mode  80       NN                         9   OUT    i it     RELI     U 706                            Fo1      cO  j  02             901 k                                                         Sensor j 9               Logic                         o    ch FFE93 our  100   H REL1    O4                                                          Fonction sch  ma des connexions    27    4  Utilisation conforme    L appareil de commutation ne peut accomplir sa t  che de s  curit   que s il est utilis   de facon conforme   L utilisation conforme de l appareil de commutation c est l utilisation comme dispositif de protection en  rapport avec les tapis de s  curit    les bumpers de s  curit   et les profils des contacts de s  curit   avec une  r  sistance de 8 2 kQ pour la surveillance du courant de repos    Une autre utilisation n est pas conforme  Le fabricant n est pas responsable des dommages qui proviennent  d utilisations non c
7.   6  Device overview    6 1 Versions    Polycarbonate housing with boltings for surface installation in a rough environment        Version Supply voltage       ELMON classic 41 312   230 V 50 60 Hz und 24 V AC DC       ELMON classic 41 812   115 V 50 60 Hz und 24 V AC DC       6 2 Signal indicators 111111    Ran    ELMON classic 41 312    LED Power  green    Operating state  on    Fault alarm  pulse    LED Fault  red    Sensor operated  on    Sensor power circuit interrupted   fast flashing    Fault self retaining   slow flashing     LED AUX  yellow   Signal output switched             If there is no fault alarm  the operating state is shown via the Power LED  on   When a fault alarm is issued   the number of pulses output indicates the fault     Fault alarm    Voltage supply outside the valid value range       Fault when testing signal input       Output control relay faulty       Data transmission between micro controllers faulty       6 3 Connection terminals    ELMON classic 41 312  Supply voltage 230 V 50 60 Hz  ELMON classic 41 812  Supply voltage 115 V 50 60 Hz    24V AC DC  Supply voltage 24 V AC DC       Connection sensor       Switching contact safety relay 1       Switching contact safety relay 2       Switching contact signaling relay       Connection manual reset  re start  key NO  optional        18    ELMON classic 41 312   ELMON classic 41 812  Safety Relais    6 4 DIP switch for configuring the operating mode  S1  AUX      ON   Automatic reset     OFF     Fau
8.   EN 61000 6 3 2007    Contr  le CE de la conception   Notified Body 0044   T  V NORD CERT GmbH   Langemarckstra  e 20   D 45141 Essen   Attestation d examen CE N    44 205 13176203    Cette d  claration de conformit   ne d  gage pas le constructeur fabricant de son obligation  d assurer la conformit   de l enti  ret   de la machine sur laquelle on a plac   ce produit   conform  ment    la directive CE     Fabricant et fond   de pouvoir     ASO  Antriebs  und Steuerungstechnik GmbH   Hansastra  e 52  D 59557 Lippstadt    35    ELMON    Sicherheitsschltgerat   Safety Relais   Relais de s  curit      Deutsch    English    Francais       36    11 DB 18 001 Betriebsanleitung Rev 01  Technische Anderungen vorbehalten   F  r Irrt  mer und Druckfehler kann keine Haftung   bernommen werden     Diese Betriebsanleitung ist f  r folgende Versionsst  nde g  ltig   von V 1 0 bis V 1 0    11 DB 18 001 Operating Manual Rev 01  Subject to technical modifications   No liability can be assumed for errors or misprints     This operating manual is valid for the following versions   from V 1 0 to V 1 0    11 DB 18 001 Manuel d utilisation R  v 01  Sous r  serve de modifications techniques   Nous d  clinons toute responsabilit   en cas d erreurs et de fautes d impression     Ce mode d emploi n est valable que pour les versions suivantes   deV1 0aV1 0    Antriebs  und Steuerungstechnik      Safet y Hansastra  e 52 e D 59557 Lippstadt TR CERT    Solutions    Tel    49 2941 9793 0    Fax   49 2941 97
9.  Elektrofachkr  ften durchgef  hrt werden  Sicherheitsvorschriften  der Elektrotechnik und der Berufsgenossenschaft sind zu beachten     Bei Arbeiten am Schaltger  t ist dieses spannungsfrei zu schalten und auf Spannungsfreiheit zu pr  fen  und gegen Wiedereinschalten zu sichern     Werden die potentialfreien Anschl  sse der Sicherheitsschaltkontakte mit einer gef  hrlichen Spannung  fremdgespeist  ist sicherzustellen  dass diese bei Arbeiten an dem Schaltger  t ebenfalls abgeschaltet  werden     Das Schaltger  t enth  lt keine vom Anwender zu wartende Bauteile  Durch eigenm  chtige Umbauten  bzw  Reparaturen am Schaltger  t erlischt jegliche Gew  hrleistung und Haftung des Herstellers     Hilfsausg  nge d  rfen keine sicherheitsgerichteten Funktionen ausf  hren  Sie sind nicht einfehlersicher  und werden auch nicht durch Testung   berpr  ft     F  r die normenkonforme Auslegung des Sicherheitssystems muss die Anlage von Sachkundigen  AN in geeigneten Zeitabstanden auf korrekte Funktion gepr  ft werden     Die Pr  fung muss in jederzeit nachvollziehbarer Weise dokumentiert werden     Bei Nichtbeachtung oder vors  tzlichem Missbrauch entf  llt die Haftung des Herstellers     ELMON classic 41 312   ELMON classic 41 812  Sicherheitsschaltgerat    3  Allgemeines und Funktionsbeschreibung    Das Schaltgerat ELMON classic 41 312  41 812  dient zur Auswertung von Signalgebern wie Sicherheitskontakt   matten  Sicherheitskontaktleisten und Sicherheitsbumpern zur Absicherung von Quetsc
10.  Reden Wi a dat CER ak 29  6 4 Commutateur DIP pour r  glage mode de fonctionnement           30  7  Modes de fonctionnement                        30  7 1 Sortie  de s  Curit    422  48 6 ub RH RR Tu gd 30  7 2 R  initialisation automatique                            30  7 3  Enclenchement d erreur   r  initialisation manuelle                 30  7 4 Sortie de signal    action instantan  e  RLU                     30  7 5 Signal de sortie ralenti  RL                              30  8  Fixation m  canique                            31  9  Connexion   lectrique                           31  9 1 Tension d alimentation                                31  9 2 Connexion du   metteur de signal                          31   9 3 Connexion de plusieurs   metteurs de signal par  circuit de   metteur de signal                            31  9 4 Connexion circuit de c  blage   lectrique                      32  9 5 Connexion r  initialisation                                32  9 6 Connexion contact de signalisation                          32  10  Mise en service et essai de fonction                   33  11  Diagnostic d erreur                            33  12  Mise hors tension et recyclage                      33  13  Donn  es techniques                            34  14  D  claration de conformit   CEE                     35    Des modifications techniques et importantes pour le fonctionnement par rapport     cette documentation pour les produits et appareils sont toujours interdite
11.  Schaltger  tes ist beliebig   sollte jedoch zum Schutz vor eindringender Feuchtigkeit so  montiert werden  dass die Kabeleinf  hrungen nach unten zeigen     9  Elektrischer Anschluss      Der Anschluss an die falschen Klemmen kann das Schaltger  t zerst  ren     Flexible Anschlussleitungen sind gegen Verlagern zu sichern  Die Netzzuleitungsadern sind  durch Isolierschl  uche zus  tzlich zu isolieren       Leitungen die im Freien oder au  erhalb vom Schaltschrank verlegt werden  m  ssen ent   sprechend gesch  tzt werden  F  r den ungesch  tzten AuRenbereich darf nur ein entsprechend  zugelassenes Kabel verwendet werden  zum Beispiel Gummileitung        Die in den  Technischen Daten  angegebenen Grenzwerte f  r die Versorgungsspannung und  Schaltverm  gen des Relais sind zu beachten     9 1 Versorgungsspannung    Die Spannungsversorgung kann wahlweise mit Netzspannung 230 V AC 50 60 Hz  ELMON rail  41 822  115 V AC 50 60 Hz  oder mit Kleinspannung 24 V AC DC erfolgen  Bei Versorgung mit 24 V  AC DC  muss die Spannung den Anforderungen f  r Schutzkleinspannung  SELV  entsprechen   Die Versorgungsleitung zum Schaltger  t ist mit einer passenden Sicherung zu sch  tzen     Niemals beide Spannungen gleichzeitig anlegen     Die 230 V Versorgungsspannung ist an die Klemmen L1 N anzulegen  F  r den Betrieb mit 24 V ist die  Versorgungsspannung an den Klemmen 24V AC DC anschlie  en     Bei einer Festinstallation muss eine Trenneinrichtung vorhanden sein  zum Beispiel Hauptschalter f  r
12.  das  System   Ein Netzstecker ist als Trenneinrichtung ausreichend  wenn er frei zug  nglich ist     9 2 Anschluss des Signalgebers    Der Signalgeber mit einem Abschlusswiderstand von 8 2 kO muss an die Klemmen IN angeschlossen werden     9 3 Anschluss von mehreren Signalgebern pro Signalgeberkreis    AN ASO Signalgeber d  rfen nicht parallel geschaltet werden     An dem Signalgebereingang k  nnen ein oder mehrere Signalgeber angeschlossen werden  Hierf  r werden  die einzelnen Signalgeber in Serie geschaltet  Bild 1      Sicherheitskontaktleiste SENTIR edge     Es k  nnen maximal 5 SENTIR edge in Serie geschaltet werden  Die maximale Gesamtlange der SENTIR edge  darf 100 m nicht   berschreiten     Die Lange einer SENTIR edge kann bis zu 25 m betragen   Die Gesamtleitungslange der in Serie geschalteten SENTIR edge darf 25 m nicht   berschreiten   Sicherheitskontaktpuffer SENTIR bumper     Es k  nnen maximal 5 SENTIR bumper in Serie geschaltet werden  Die maximale Gesamtl  nge der SENTIR  bumper darf 15 m nicht   berschreiten     Die L  nge eines SENTIR bumper kann bis zu 3 m betragen   Die Gesamtleitungslange der in Serie geschalteten SENTIR bumper darf 25 m nicht   berschreiten   Sicherheitskontaktmatte SENTIR mat     Es k  nnen maximal 10 SENTIR mat in Serie geschaltet werden  Die maximale Gesamtflache darf 10 m  nicht    berschreiten     Die Gr    e einer SENTIR mat kann bis zu 1350 x 2350 mm betragen   Die Gesamtleitungslange der in Serie geschalteten SENTIR mat darf 25
13.  m nicht   berschreiten   Vor dem Anschlie  en der in Serie geschalteten Signalgeber ist es empfehlenswert  den Widerstandswert    der Verschaltung auszumessen  Bei unbet  tigtem Signalgeber muss der Widerstand 8 2 KQ   500 O betragen   Ist der Signalgeber bet  tigt  darf der Widerstand 500 O nicht   berschreiten     Signalgeber 1 Signalgeber 2 Signalgeber    n    gll    9   I       2 Mon 2    Bild 1  Verschaltung mehrerer Signalgeber  hier am Beispiel Sicherheitskontaktleiste                                                                   9 4 Anschluss Steuerstromkreise    Die zu   berwachenden Steuerstromkreise sind an die Klemmen STOP 1 und STOP 2 anzuschlie  en  Wenn  eine redundante Weiterf  hrung der Schaltkontakte nicht gew  nscht ist  kann eine Br  cke zwischen STOP 1  und STOP 2 eingesetzt werden     Bei redundanter Verwendung der Schaltkontakte d  rfen nur Spannungen mit gleichem Potential  angeschlossen werden  Die Verwendung von unterschiedlichen Spannungspotentialen entspricht  keiner bestimmungsgem    en Verwendung     Die Steuerstromkreise sind abh  ngig vom Nennstrom mit einer entsprechenden Sicherung zu sch  tzen   oder der Nennstrom auf den Steuerstromkreisen muss durch andere Ma  nahmen auf den maximalen Wert  begrenzt werden     9 5 Anschluss Reset    F  r die Betriebsart    manueller Reset  muss der notwendige Reset Schalter an die Klemmen RESET ange   schlossen werden     9 6 Anschluss Meldekontakt    Der Meldekontakt AUX dient lediglich als Hilfskonta
14.  peut   tre de 25 m    La longueur maximale des c  bles des SENTIR edge monter en s  rie ne doit pas d  passer 25 m     Bumper de s  curit   SENTIR bumper     Il est possible de monter au plus 5 SENTIR bumper en s  rie  La longueur totale des SENTIR bumper ne doit  pas d  passer 15 m    La longueur max  d un SENTIR bumper peut   tre de 3 m    La longueur maximale des c  bles des SENTIR bumper monter en s  rie ne doit pas d  passer 25 m     Tapis de s  curit   SENTIR mat     Il est possible de monter au plus 10 SENTIR mat en s  rie  La surface totale ne doit pas d  passer 10 m2   Dimensions maximales d un SENTIR mat est de 1350 x 2350 mm   La longueur maximale des c  bles des SENTIR mat monteren s  rie ne doit pas d  passer 25 m     Avant le raccordement des   metteurs de signaux en s  rie  il est recommand   de mesurer la valeur ohmique  du c  blage  Quand l   metteur de signaux est au repos  la r  sistance doit   tre de 8 2 KQ   500 Q  Si l   metteur  de signaux est actionn  e  la r  sistance ne doit pas exc  der 500 Q                metteur de signaux 1   metteur de signaux 2   metteur de signaux   n                                                          o 5 i    1 zx ge 2    Figure 1  connexion de plusieurs   metteurs de signal  ici par exemple sur le profil de contact de s  curit                                  9 4 Connexion circuit de c  blage   lectrique    Les circuits de c  blage   lectrique    surveiller doivent   tre connect  s sur les bornes STOP 1 et STOP 2   Q
15.  tre v  rifi  es  cables   cras  s  cables cassants   non raccord    etc    mal raccord   ou d  fectueux    v  rifier le   metteur de signal      La LED rouge  Fault  clignote rapidement          La LED rouge  Fault R  serve d erreur effectuer une r  initialisation manuelle  clignote lentement          Si l erreur n est pas due au c  blage  on peut tester la fonctionnalit   de l   lectronique en programmant  l entr  e du   metteur de signal sur l appareil commutateur avec une r  sistance de 8 2 kO  Si ensuite   l   lectronique fonctionne parfaitement  le   metteur de signal doit   tre test   avec un appareil de  mesure de r  sistance  Pour ce faire  la connexion du   metteur de signal doit   tre enlev  e de l appareil  de commutation et   tre connect  e    un appareil de mesure de r  sistance  Si le   metteur de signal  n est pas enclench    la r  sistance doit   tre de 8 2 KQ  500 Q  Si le   metteur de signal est enclench    la  r  sistance ne peut d  passer 500 O     12  Mise hors tension et recyclage    Les produits fabriqu  s par ASO ne sont pr  vus que pour un usage industriel  B2B   Apr  s la fin de l utilisation   les produits doivent   tre recycl  s selon les normes locales  r  gionales et nationales  ASO reprend volontiers  les produits et les recycle comme il se doit     33    13  Donn  es techniques    R  sistance terminale de  Tension d alimentation l   metteur de signaux    ELMON classic 41 312  230 V CA 50 60 Hz    valeur nominale    eset elu meseci Ure  LE MON 
16. 238 23 8 E Xn   E XU 12  14  EG Konformit  tserkl  rung                        13    Technische und betriebsrelevante   nderungen zu den in dieser Dokumentation  aufgef  hrten Produkten und Ger  ten sind jederzeit auch ohne Vorank  ndigung vor   behalten     2  Allgemeine Sicherheitsbestimmungen und Schutzmafinahmen    Hersteller und Benutzer der Anlage   Maschine  an der die Schutzeinrichtung verwendet wird  sind daf  r  verantwortlich  alle geltenden Sicherheitsvorschriften und  regeln in eigener Verantwortung abzustimmen  und einzuhalten     Die Schutzeinrichtung garantiert in Verbindung mit der   bergeordneten Steuerung eine funktionale  Sicherheit  nicht aber die Sicherheit der gesamten Anlage   Maschine  Vor dem Einsatz des Ger  tes  ist deshalb eine Sicherheitsbetrachtung der gesamten Anlage   Maschine nach der Maschinenrichtlinie  2006 42 EG oder nach entsprechender Produktnorm notwendig     Die Betriebssanleitung muss st  ndig am Einsatzort der Schutzeinrichtung verf  gbar sein  Sie ist von  jeder Person  die mit der Bedienung  Wartung oder Instandhaltung der Schutzeinrichtung beauftragt  wird  gr  ndlich zu lesen und anzuwenden     Die Installation und Inbetriebnahme der Schutzeinrichtung darf nur durch Fachpersonal erfolgen  die  mit dieser Betriebsanleitung und den geltenden Vorschriften   ber Arbeitssicherheit und Unfallverh     tung vertraut sind  Die Hinweise in dieser Anleitung sind unbedingt zu beachten und einzuhalten     Elektrische Arbeiten d  rfen nur von
17. 93 299 ISO 9001  www asosafety com e e mail  info asosafety com          
18. ELMON classic 41 312  ELMON classic 41 812       Betriebsanleitung    Operating Manual    Manuel d utilisation      bergabedokumentation   Documentation   Documentation de datation    Anlagenbeschreibung   Description   Description du systeme    Anlagenart   Type of plant   Sorte du syst  me       Hersteller   Manufacturer   Fabricant       Seriennummer   Serial number   Num  ro de s  rie       Datum der Inbetriebnahme   Commissioning date   Date de mise en marche       Aufstellort   Site of installation   Lieu de montage       Verwendete Steuerung   Control unit   Commande utilis  e       Zusatzkomponenten   Additional components   Composants suppl  mentaires    Funktionspr  fung   Functional test   Contr  le de fonction    Sicherheitssensoren reagieren auf Bet  tigung   Safety sensor response to actuation    Le senseur de s  curit   r  agit    l actionnement    Sicherheitssensoren reagieren auf Zuleitungsunterbrechung   Safety sensor response to supply  line interruption   Le senseur de s  curit   r  agit    l interruption de l alimentation       Name der ausf  hrenden Firma   Owner   Nom de la soci  t   ex  cutrice       Name des Installateurs   Installer   Nom de l installateur          Datum   Date   Date Unterschrift   Signature   Signature    ELMON classic 41 312   ELMON classic 41 812  Sicherheitsschaltger  t    1  Inhaltsverzeichnis    1  Inhaltsverzeichnis                             3  2  Allgemeine Sicherheitsbestimmungen und Schutzma  nahmen   4  3  Allgemeines u
19. OFF      In this operating mode the AUX signaling output is Aux  Relay       activated with a delay of 0 5 seconds and then remains  active for amaximum of 3 seconds  if a fault is signaled              Safety output  symbolic   Signaling output  symbolic     19    8  Mechanical mounting  Polycarbonate housing with boltings for surface installation in a rough environment     The switching device must be mounted properly in a suitable mounting location  After the  A lid has been removed  the casing can be mounted by means of four bolts   e Do not install in the immediate vicinity of an intense heat source   e The unit must not be operated in areas with major temperature changes     The switching unit can be installed in any position  but in order to protect against any ingress of humidity it  should be fitted such that the cable entries point downwards     9  Electrical connection      The switching unit can be destroyed by connection to the incorrect terminals     Flexible connection leads must be secured against any shifting  The mains infeed wires must  be additionally insulated by means of insulation tubes       Lines that are routed in the open air or outside the switch cabinet must be protected accor   dingly  For the unprotected external area only an appropriately approved cable may be used   for example  rubber lead        The limit values stated in the  Technical Data  for the supply voltage and the switching  capability of the relay must be observed     9 1 Supply vo
20. ailable  An operation of the sensor causes a  reaction of the signal output in accordance with the DIP switch configuration  The signal output must not  execute any safety orientated functions  It is not fail safe and not checked by testing either     The switching device has been designed and type approved in accordance with EN ISO 13849 1  Safety   related parts of control systems  for category 3 Performance Level e  For compliance with category 3  the  safety output is set up redundantly with two independent switching elements     In addition the device has been type approved according to EN 62061  Functional safety of safety related  electrical  electronic and programmable electronic control systems  and can meet a safety function up to  SIL3     The monitoring state of the sensor and the applied operating voltage are indicated by LED     If there is a fault alarm  all safety outputs are inactive     an altitude of 2000m above mean sea level  The unit must not be operated in areas with major    The unit can be used in a household environment as well as in an industrial environment up to  A temperature changes           11013 ELMON classic 41 312  230 V AC  HO 14  ELMON classic 41 812  115 V AC                    DIL Switch           ki    i 1  Manual 79    Reset 1012 24V AC DC    Reset 80 Mode                   Los     OUT  H   f RELL                                      U Op                   9ol1   e e                                                       Sensor   9    
21. an external source  it must be ensured that these are also switched off when working on the  switching device     e The switching device does not contain any components that the user must service  Any warranty or  liability on the part of the manufacturer is forfeited in the event of any unauthorized modifications or  repairs to the switching device     e Auxiliary outputs must not execute any safety orientated functions  They are not fail safe and are not  checked by testing either     The system must be checked for correct function in suitable intervals by qualified persons for the  AN standard conform design of the safety system     The check must be documented in a way that allows it to be traced at any time     In the case of non compliance or deliberate abuse  the manufacturer s liability will cease     15    3  General and function description    The ELMON classic 41 312 switching device is used to evaluate sensors such as safety contact mats  safety  contact strips and safety bumpers for securing crush and shear locations     An ASO sensor can be connected to the switching device  The steady state current monitoring of the sensor  is made possible by an integrated terminating resistor in the sensor     If the desired steady state current flows  the safety relays are driven and the switching contacts closed   If the sensor is operated or the sensor circuit is interrupted  the relay switching contacts open     A signal output with potential free switching contacts is av
22. classic 41 812  115 V CA 50 60 Hz          valeur sup  rieure    Type de connexion r  seau Type X de commutation       Basse tension UE 24 V CA CC  10  Alerter  Puissance absorb  e Ppr  seau_max 2 2 VA 230 V CA  ou 115 V  de commutation  PE max  1 5 W 24 V CC  PE max  1 2 VA 24 V CA                      Relais de s  curit   Relais de signalisation  Courant nominal CC 3A  30V CC  Max  courant de 2 A  30 V CC     Courant nominal CA 1A  230 V CA  commutation EE  Dur  e de vie m  canique  gt  10   actionnements  Dur  e de vie m  canique  gt 10   actionnements    Mode de fonctionnement RL    ub Retard    l enclenchement   temps de r  action  Mode de fonctionnement RL   Temps de d  connexion 500 ms  Power on 700ms  Dur  e d enclenchement  AC 15  230V CA  1A  550000 Op     Pour la version RLU  le relais de signalisation s allume en  DC 13  30V CC  3A  120000 Op     m  me temps que l enclenchement du   metteur de signal                    Retard au d  clenchement 0 5 Sek       12ms                Cat  gorie d utilisation                   Bo  tier AB  couvercle transparent   polycarbonate  ra 120  Dimensions  HxLxP   Bo  tier 120 x 80 x 56 mm  Bo  tier  presse   toupe incl  120 x 102 x 56 mm  Indice de protection  avec presse   toupe M16 IP65  avec bouchons M16 IP54  Classe de protection Il  isolation de protection        Niveau de pollution 2  Cat  gorie de surtension Hl  Tension d isolation calcul  e 250V  Tension nominale d essai 4 00 kV  Poids 350g  Zone de temp  rature  20   C  
23. d adhering to all applicable safety rules and regulations under their own responsibility     e The protection system guarantees functional safety in combination with the superordinate control  system  but not the safety of the entire system machine  Thus  a safety review of the entire system   machine in accordance with machine directive 2006 42 EC or relevant product standards is necessary  prior to use of the device     e The operating instructions must be permanently available at the operating location of the protection  device  They must be thoroughly read and applied by every person who is tasked with the operation   maintenance or repair of the protection device     e The installation and start up of the protection device may only be conducted by specialized personnel  who are familiar with these operating instructions and the applicable regulations on job safety and  accident prevention  The instructions in these operating instructions must be followed and adhered to  unconditionally     e Electrical work may only be carried out by skilled electricians  Safety regulations for electrical engineering  and from the professional association must be followed     e In case work has to be carried out on the switching device  it must be switched to a voltage free position  and checked for freedom from any voltage and secured against being switched back on again     e If the potential free connections of the safety switching contacts are supplied with a hazardous voltage  from 
24. e   berwachung von einer Sicherheitskontaktleiste mit Startfreigabe   ber Freigabetaster  und getrennter Weiterf  hrung der Steuerstromkreise  Kategorie 3 konforme Anwendung nach EN ISO 13849 1   Zur Funktionskontrolle der Lastsch  tze K1 und K2 werden die Offnerkontakte dieser Sch  tze in den Start Kreis   RESET  eingebunden    Der Melderelais Ausgang dient zur Visualisierung des Schaltzustandes der Sicherheitskontaktleiste   Schaltbild im spannungslosen Zustand  Sensor nicht bet  tigt    1 Signalgeber  Leiste  Matte oder Bumper    2 Freigabetaster    6    ELMON classic 41 312   ELMON classic 41 812  Sicherheitsschaltger  t    6  Ger  te  bersicht    6 1 Ausf  hrungen    Polycarbonat Geh  use mit Verschraubungen f  r Aufputzmontage in rauer Umgebung        Ausf  hrung Versorgungsspannung       ELMON classic 41 312   230 V 50 60 Hz und 24 V AC DC       ELMON classic 41 812   115 V 50 60 Hz und 24 V AC DC       6 2 Signalanzeigen    LED Power  gr  n   Betriebszustand  an   Fehlermeldung  Pulsausgabe   LED Fault  rot   Signalgeber bet  tigt  an   Signalgeberstromkreis unterbrochen   blinkt schnell   Fehlerselbsthaltung   blinkt langsam     LED AUX  gelb   Meldeausgang geschaltet    n5 Safety  WM Solutions  ELMON classic 4    PN  1114 0060 M             Liegt keine Fehlermeldung vor  so wird Uber die LED Power der Betriebszustand angezeigt  an   Bei Ausgabe  einer Fehlermeldung gibt die Anzahl der ausgegebenen Pulse den Fehler an     Fehlermeldung  1    Spannungsversorgung au  e
25. e cisaillement    Sur l appareil de commutation  on peut fixer un g  n  rateur de signal ASO  La surveillance du courant de  repos du g  n  rateur de signal est rendue possible gr  ce    une r  sistance de terminaison int  gr  e dans le  g  n  rateur de signal    Si le courant au repos du d  bit circule  les relais de s  curit   sont cingl  s et le contact d allumage est ferm     Si l on actionne le g  n  rateur de signal ou si le circuit du g  n  rateur de signal est interrompu  les contacts  d allumage relais s ouvrent    Une sortie de signalisation avec des contacts d allumage potentiellement libres est disponible  Si l on  actionne le g  n  rateur de contact  cela d  clenche une r  action du signal de sortie qui correspond    la  configuration du commutateur DIP  La sortie de signalisation ne peut effectuer aucune fonction s  curis  e   Ce n est pas s  r et cela n a pas   t   test      L appareil de commutation correspond    la norme EN ISO 13849 1  pi  ces de classification de s  curit   des  contr  leurs  pour cat  3 Niveau de performance expliqu   et homologu    Pour la conformit   de la cat  gorie 3   la sortie de s  curit   est redondante et construite avec deux   l  ments de commutation ind  pendants    En compl  ment  l appareil a   t   homologu   selon la norme EN 62061  S  curit   fonctionnelle de syst  mes  s  curis  s   lectriques    lectroniques et de commandes programmables   lectroniquement    et peut avoir  une fonction s  curitaire allant jusqu    SIL    L
26. e signalisation  connexion AUX  allume la position de l interrupteur DIP disponible  Celui ci est  affich      l aide de LED jaunes AUX    Le syst  me de s  curit   doit   tre v  rifi      intervalles r  guliers  La v  rification doit    chaque fois   tre  effectu  e de mani  re document  e  Les exigences du fabricant du site de la machine doivent   tre prises en  compte et respect  es     11  Diagnostic d erreur    En cas de c  blage correct et pose correcte de la tension d alimentation  seule la LED verte Power peut   tre allum  e   Si la LED rouge s allume  il y a une erreur dans le syst  me qui sera limit  e    l aide des LED     mi rm   p    V  rifier les connexions et la tension d alimentation     230 V CA  ou 115 V  aux bornes L1 N ou    24 V CA CC    la borne 24 V AC DC   Zone de tol  rance   10     La LED verte La tension d alimentation  Power manque  est trop faible  ne s allume pas ou mal connect  e        La LED verte  Power l erreur interne sera affich  e   clignote de facon cyclique par le nombre d impulsions    donn  e d impulsion     Voir   gt  signaux         les connexions des   metteurs de signal correspondants  doivent   tre v  rifi  es  c  bles   cras  s  c  bles cassants   etc       v  rifier le   metteur de signal      La LED rouge Le   metteur de signal  Fault correspondant est consid  r    clignote comme enfonc          Circuit de   metteur de signal    les connexions des   metteurs de signal correspondants  interrompu    metteur de signal   doivent  
27. ebrachten Ausf  hrung  den  einschlagigen grundlegenden Sicherheits  und Gesundheitsanforderungen der nach   folgenden EG Richtlinien entspricht     EG   Maschinenrichtlinie 2006 42 EG  EN ISO 13849 1 2008   EN ISO 13849 2 2013   EN 62061 2013 09   EN 60947 5 1 2010 04   EN 61000 6 2 2005   EN 61000 6 3 2007    EG   Baumusterpr  fung   Notified Body 0044   T  V NORD CERT GmbH   Langemarckstra  e 20   D 45141 Essen   EG Baumusterpr  fbescheinigung Nr   44 205 13176203    Diese Konformit  tserkl  rung entbindet den Konstrukteur Hersteller der Maschine nicht  von seiner Pflicht  die Konformit  t der gesamten Maschine  an der dieses Produkt ange   bracht wird  entsprechend der EG Richtlinie sicherzustellen     Hersteller und Dokumentenbevollm  chtigter     ASO  Antriebs  und Steuerungstechnik GmbH   Hansastra  e 52  D 59557 Lippstadt    13    1  Table of Contents    1  Table of Contents                             14  2  General safety regulations and protection measures         15  3  General and function description                    16  4   Intended user  ue ote mo AE tarder 17  5  Application example                            17  6  Device overview                             18  B l VEVSIONS  usos d   els de na 18  6 2  Signal indicators    duo ore de AS Ge DICERE UY a end 18  6 3 Connection terminals                                18  6 4 DIP switch for configuring the operating mode                  19  7  Operating modes                             19  7 1     Safety ou
28. eder frei  wenn die Kontakte RESET  500 ms nach Beseitigung der St  rung    mit einem Taster geschlossen werden  Ein automatisches Wiederanlaufen ist so ausgeschlossen   Ein dauerhaftes   berbr  cken der Kontakte RESET f  hrt nicht zu einer automatischen R  cksetzung     7 4 Meldeausgang unverz  gert  RLU  mu   S2      ON     Output       In dieser Betriebsart wird der Meldeausgang AUX  unverz  gert aktiviert  wenn ein beliebiger Fehler am  entsprechenden Kanal signalisiert wird  Der Ausgang  ist im stromlosen Zustand des Schaltger  tes immer  inaktiv ist  Sicherheitsausgang  symbolisch   Meldeausgang  symbolisch           Aux  Relay                7 5 Meldeausgang verz  gert  RL  Output   S2      OFF      In dieser Betriebsart wird der Meldeausgang AUX um Aux  Relay       0 5 Sekunden verz  gert aktiviert und bleibt dann f  r  max  3 Sekunden aktiv  wenn ein Fehler signalisiert wird              Sicherheitsausgang  symbolisch   Meldeausgang  symbolisch     ELMON classic 41 312   ELMON classic 41 812  Sicherheitsschaltger  t    8  Mechanische Befestigung  Polycarbonat Geh  use mit Verschraubungen f  r Aufputzmontage in rauer Umgebung   e Das Schaltger  t ist fachgerecht an einem geeigneten Montageort zu befestigen  Nach Entfernen  VAN  des Deckels kann das Geh  use mit vier Schrauben befestigt werden   e Nicht in unmittelbarer N  he von starken W  rmequellen montieren     Das Ger  t darf nicht in Bereichen mit starken Temperaturwechseln betrieben werden     Die Einbaulage des
29. es travaux sur l appareil de commutation  il faut qu il soit hors tension et il faut v  rifier  la mise hors tension et le fait qu il ne peut pas se remettre en marche     Si les connexions potentiellement libres des contacts de commutation de s  curit   sont aliment  es par  une source externe avec une tension dangereuse  il faut s assurer que celles ci sont   galement d  con   nect  es lors de travaux    l appareil de commutation     L appareil de commutation comprend des pi  ces    entretenir par l utilisateur  Si l on apporte des  modifications voire des r  parations    l appareil de commutation  la garantie et la responsabilit   du  fabricant disparaissent     Les sorties auxiliaires ne peuvent ex  cuter aucune fonction s  curis  e  Vous n avez pas la s  curit    int  gr  e et n   tes pas test         Pour l interpr  tation dans les normes du syst  me de s  curit    le site doit   tre v  rifi   par des experts    aux moments pr  conis  s pour s assurer de son bon fonctionnement   La v  rification doit toujours   tre bien document  e     En cas de non respect ou d abus intentionnel  le fabricant n est plus responsable     26    ELMON classic 41 312   ELMON classic 41 812  Relais de s  curit      3  G  n  ralit  s et description de fonction    L appareil de commutation ELMON classic 41 312 sert au traitement du g  n  rateur de signal comme les  tapis de s  curit    les profils de contact de s  curit   et les bumpers de s  curit   pour assurer les points  d   crasement et d
30. h  und Scherstellen     An das Schaltger  t kann ein ASO Signalgeber angeschlossen werden  Die Ruhestrom  berwachung des  Signalgebers wird durch einen integrierten Abschlusswiderstand im Signalgeber erm  glicht     Flie  t der Soll Ruhestrom  so sind die Sicherheitsrelais angesteuert und die Schaltkontakte geschlossen   Wird der Signalgeber bet  tigt oder der Signalgeberstromkreis unterbrochen    ffnen die Relais Schaltkon   takte     Ein Meldeausgang mit potentialfreien Schaltkontakten ist verf  gbar  Eine Bet  tigung des Signalgebers  bewirkt eine Reaktion des Meldeausganges entsprechen der DIP Schalter Konfiguration  Der Meldeausgang  darf keine sicherheitsgerichtete Funktionen ausf  hren  Er ist nicht einfehlersicher und wird auch nicht  durch Testung   berpr  ft     Das Schaltger  t ist nach EN ISO 13849 1  Sicherheitsbezogene Teile von Steuerungen    f  r Kat  3 Performance  Level e ausgelegt und baumustergepr  ft  F  r die Einhaltung der Kategorie 3 ist der Sicherheitsausgang  redundant mit zwei unabh  ngigen Schaltelementen aufgebaut     Zus  tzlich ist das Ger  t nach EN 62061   Funktionale Sicherheit sicherheitsbezogener elektrischer  elektro   nischer und programmierbarer elektronischer Steuerungssysteme  baumustergepr  ft und kann eine Sicher   heitsfunktion bis SIL 3 erf  llen     Der   berwachungszustand des Signalgebers und die angelegte Betriebsspannung werden durch LED ange   zeigt     Wenn eine Fehlermeldung vorliegt  sind alle Sicherheitsausgange inaktiv  
31. hazards at crush and shear locations corresponds to  the relevant basic safety and health requirements of the following EC Directives as a  result of its conception and construction as well as the design we put on the market     EC   machinery directive 2006 42 EG  EN ISO 13849 1 2008   EN ISO 13849 2 2013   EN 62061 2013 09   EN 60947 5 1 2010 04   EN 61000 6 2 2005   EN 61000 6 3 2007    EC   type approval   Notified Body 0044   T  V NORD CERT GmbH   Langemarckstra  e 20   D 45141 Essen Germany   EC   Design certification No   44 205 13176203    This declaration of conformity does not absolve the machine designer manufacturer of  his obligation to guarantee the conformity of the overall machine to which this product is  attached in accordance with the EC Directive     Manufacturer and authorized representative for documents     ASO  Antriebs  und Steuerungstechnik GmbH   Hansastra  e 52  D 59557 Lippstadt    24    ELMON classic 41 312   ELMON classic 41 812  Relais de s  curit      1  Table des mati  res    1  Table des mati  res                             25  2  Normes de s  curit   g  n  rales et mesures de protection       26  3  G  n  ralit  s et description de fonction                  27  A  Utlisation conforme    iuo o moon UR d aed 28  5  Exemple d application                            28  6  Aper  u de l appareil                            29  Gide   Mod  les s sis ne tire ent a d un EE aec Kn A 29  6 2  SPA RN  Ie cede i re Sue 29  6 3 Bornes de connexion    ies
32. ire avec une tension de r  seau de 230 V CA  AN 50 60 Hz ou avec une basse tension de 24V CA CC  En cas d alimentation avec du 24 V CA CC    la tension doit r  pondre aux exigences de basse tension pour protection  SELV   La tension   d alimentation pour l appareil commutateur doit   tre prot  g  e avec un fusible qui convient     Ne jamais utiliser les deux tensions en m  me temps     La tension d alimentation de 230 V  115 V  doit   tre raccord  e aux bornes L1 N  Pour l utilisation avec 24 V   il faut raccorder la tension d alimentation aux bornes 24V CA CC     En cas d installation fixe  il doit y avoir un dispositif s  par    par exemple un interrupteur d alimentation  principal pour le syst  me   Une prise est un dispositif de s  paration suffisant quand elle est facilement  accessible     9 2 Connexion du   metteur de signal    Le   metteur de signal doit   tre connect   avec une boite de r  sistance terminale de 8 2 kO aux bornes IN   9 3 Connexion de plusieurs   metteurs de signal par circuit de   metteur de signal    A Les   metteurs de signal ASO ne peuvent pas   tre connect  s en parall  le     On peut connecter    l entr  e du   metteur de signal un ou plusieurs   metteurs de signal  Pour ce faire   les   metteurs de signal sont connect  s selon l image 1  en s  rie     31    Barre palpeuse SENTIR edge     Il est possible de monter au plus 5 SENTIR edge en s  rie  La longueur totale des SENTIR edge ne doit pas  d  passer 100 m    La longueur max  d un SENTIR edge
33. is correctly wired and applied  only the green Power LED may be lit up  If the red LED  illuminates  there is a fault in the system which can be delimited by means of the LED     e   Fault Fault removal    Check connections and supply voltage      230 V AC  or 115 V  at terminals L1 N or     24 V AC DC at terminals 24 V AC DC  Tolerance range   10     green LED Supply voltage is missing   Power too low or  does not light up incorrectly connected        green LED  Power Internal fault is indicated  flashes cyclically by the number of pulses    pulse output     See     signal displays       red LED The corresponding sensor   Check the connections of the corresponding sensors  Fault is recognized  squeezed or brittle supply lines  etc    lights up as being operated    Check signal sensor         red LED Sensor circuit interrupted    Check the connections of the corresponding sensors  Fault sensor not connected   squeezed or brittle supply lines  etc    fast flashing defectively connected or defective    Check sensor      red LED  Fault Fault self retaining Carry out manual reset  slow flashing            Ifthe fault is not found in the wiring  the function of the electronic system can be checked by applying  a resistance of 8 2 kQ to the sensor input on the switching device  Subsequently  if the electronics work  perfectly  the sensor must be checked by means of an ohmmeter  For this purpose  the connection of  the sensor to the switching device must be separated and connected b
34. kt  Signalisierung  Anzeige etc   und darf nicht in den  Sicherheitsstromkreis eingebunden werden     10    ELMON classic 41 312   ELMON classic 41 812  Sicherheitsschaltgerat    10  Inbetriebnahme und Funktionspr  fung    Nach entsprechendem Anschluss aller elektrischen Verbindungen und Einschalten der Versorgungsspannung  muss die Anlage   Maschine auf korrekte Funktion gepr  ft werden    Nach erfolgreicher Inbetriebnahme sind die Sicherheitsausg  nge STOP 1 und STOP 2 angesteuert  Relais   kontakte   geschlossen    Eine Bet  tigung des Signalgebers bewirkt ein   ffnen der Relaiskontakte    Das Melderelais  Anschluss AUX  schaltet entsprechend der vorliegenden DIP Schalter Stellung  Dies wird mit  Hilfe der gelben LED AUX angezeigt    Das Sicherheitssystem muss in geeigneten Zeitabst  nden von Sachkundigen gepr  ft werden  Die Pr  fung  muss in jederzeit nachvollziehbarer Weise dokumentiert werden  Die Anforderungen des Anlagen    Maschi   nenherstellers sind zu ber  cksichtigen und einzuhalten     11  Fehlerdiagnose    Bei korrekter Verdrahtung und Anlegen der Versorgungsspannung darf nur die gr  ne LED Power leuchten  Bei  Aufleuchten der roten LED ist ein Fehler im System vorhanden  der sich mit Hilfe der LED eingrenzen l  sst      o   ome   id dida    Anschl  sse und Versorgungsspannung   berpr  fen      230 V AC  oder 115 V  an Klemmen L1 N oder     24 V AC DC an Klemme 24 V AC DC  Toleranzbereich   10     gr  ne LED Versorgungsspannung fehlt   Power zu gering  leuchte
35. l de sortie  symbolique     30    ELMON classic 41 312   ELMON classic 41 812  Relais de s  curit      8  Fixation m  canique    Etui polycarbonate avec raccords    vis pour montage en saillie en environnement rude     e l appareil commutateur doit   tre attach   de mani  re appropri  e sur un lieu de montage qui  A convient  Apr  s avoir enlev   le couvercle  l   tui peut   tre fix   avec 4 vis     Ne pas monter    proximit   directe d une source de chaleur     l appareil ne peut pas   tre utilis   dans des zones subissant de grandes modifications de  temp  rature     La situation pour le placement de l appareil est libre mais il devrait   tre mont      l abri d humidit   infiltrante  pour que le c  blage puisse aller vers le bas     9  Connexion   lectrique      Laconnexion    de mauvaises bornes peut d  truire l appareil de commutation       l faut assurer les conduits flexibles contre les d  placements  Les c  bles de connexion au  r  seau doivent   tre isol  s par des tuyaux d isolation      Les conduits qui sont    l air libre ou    l ext  rieur des armoires   lectriques doivent   tre  prot  g  s en cons  quence  Pour la zone ext  rieure  non prot  g  e  on ne peut utiliser qu un  cable autoris    par exemple conduit en caoutchouc       Les valeurs limites donn  es dans les    feuillets techniques    pour la tension d alimentation  et le pouvoir de coupure du relais doivent   tre respect  es     9 1 Tension d alimentation    La tension d alimentation peut au choix se fa
36. lt self retaining     manual reset  factory setting   S2  Reset        ON     AUX Mode signal output  RLU     OFF     AUX Mode signal output  RL  factory setting     7  Operating modes  7 1 Safety output    Separate or combined use of the control circuits  redundant continuation of the switching contacts   In order  to make joint use of the switching contacts of both relays  a bridge must be set between the STOP1 and  STOP2 connections      7 2 Automatic reset    1    ON      After removing a fault in a sensor circuit or after a voltage failure  the switching unit will automatically  release output again     7 3 Fault self retaining   manual reset    S1      OFF       After removingl a fault in a sensor circuit or after a voltage failure  the switching unit will only release the  output s  again  if the RESET contacts  500 ms after the elimination of the disruption are closed by means    of a pushbutton  This completely prevents any automatic re start  A permanent bridging of the RESET  contacts does not cause an automatic reset     7 4 Signaling output without any delay  RLU  mu   S2      ON     Output       In this mode of operation the corresponding AUX  signaling output is activated without delay  if any fault  is signaled on the corresponding channel  The output  is always inactive in the de energized state of the  switching device  Safety output  symbolic   Signaling output  symbolic           Aux  Relay                7 5 Signaling output delayed  RL  Output   S2      
37. ltage    The supply voltage can optionally be effected by means of a mains voltage of 230 V AC 50 60 Hz   ELMON rail 41 822  115 V AC 50 60 Hz  or a low voltage of 24 V AC DC  For a supply with 24 V  AC DC the voltage must correspond to the requirements for protective low voltages  SELV   The  supply line to the switching device must be protected by means of a suitable fuse     Never apply both voltages simultaneously      The 230 V supply voltage must be applied to the L1 N terminals  For operation with 24 V  the supply voltage  must be connected to the 24 V AC DC terminals     For a fixed installation a separating device must be available  for example  a main switch for the system   A  mains plug is sufficient as a separating device  if it is freely accessible     9 2 Connection of sensor    The sensor with a terminating resistor of 8 2 kO must be connected to the IN terminals     9 3 Connection of several sensors per sensor circuit    AN ASO sensors must not be connected in parallel     One or several sensors can be connected to the signal transmitter input  For this purpose  the individual  sensors are connected in series in accordance with Figure 1     20    ELMON classic 41 312   ELMON classic 41 812  Safety Relais    Safety contact edge SENTIR edge    A maximum of 5 SENTIR edge devices can be connected in series  The maximum total length of the SENTIR  edge must not exceed 100 m    The length of a SENTIR edge can be up to 25 m    The total line length of the series con
38. n  BxHxT     Geh  use 120 x 80 x 56 mm   Geh  use incl  Verschraubungen 120 x 102 x 56 mm  Schutzart   mit M16 Verschraubungen IP65   mit M16 Verschlu  stopfen IP54    Schutzklasse  Verschmutzungsgrad 2    berspannungskategorie Hl    Bemessungsisolationsspannung 250V  Bemessungssto  spannungsfestigkeit 4 00 kV  Gewicht 350g     20   C bis  55   C  ein   oder feindrahtige Leitung  0 75 1 5 mm     Temperaturbereich  Querschnitt Anschlussleitungen    Zulassungen    ELMON classic 41 312  41 812  EN ISO 13849 1 2008 Kategorie 3 PLe   MTTFd 236 Jahre  DC 99     EN 62061 2013 SILCL 3     PFHd 8 59E 09 1 h        Elektronik    MTTFd 625 Jahre  DC 99         B10d 2000000    SiS seres rds MTTFd 380 Jahre  DC 9996  Nop 52560           Pr  fbericht Nr    3512 6372    Zertifikat Nr    44 780 13 xxxxxx    EG Baumuster   pr  fbescheinigung Nr    44 205 13176203    12            ia            d    TUV NORD    T  V NORD CERT  GmbH    ELMON classic 41 312   ELMON classic 41 812  Sicherheitsschaltgerat    14  EG Konformit  tserkl  rung    Hiermit erkl  ren wir  dass die nachfolgend bezeichneten Produkte der Baureihe     ELMON rail 41 312   Artikelnummer 1114 0060  Format Seriennummer yymmnnnnn     ELMON rail 41 812   Artikelnummer 1114 0130  Format Seriennummer yymmnnnnn     Sicherheitsschaltger  t zur Kombination mit Schaltleisten  Schaltmatten und Schalt   puffern zur Vermeidung von Gefahren an Quetsch  und Scherstellen aufgrund ihrer  Konzipierung und Bauart sowie in der von uns in Verkehr g
39. nd Funktionsbeschreibung                 5  4  Bestimmungsgem    e Verwendung                   6  5  Anwendungsbeispiele                            6  6  Ger  te  bersicht                               7  6 1 Ausf  hrungen                                     7  6 2  Signalanz igen 422245 ee de ee vow ox e ro  qo 7  6 3  Anschlussklemm  n  u    2  snm a aie tn ROS a aR ea 7  6 4  DIP Schalter zum Einstellen derBetriebsart                      8  7  Betriebsarten    5 545 44 ste 02a cee ECRIRE QU RUE Sek ee 8  7 1 Sicherheitsausgang                                   8  7 2 Automatischer Reset                                  8  7 3  Fehlerselbsthaltung   manueller Reset                        8  7 4 Meldeausgang unverz  gert  RLU                            8  7 5  Meldeausgang verz  gert  RL                             8  8  Mechanische Befestigung                         9  9  Elektrischer Anschluss                           9  9 1  Versorgungsspannung                                9  9 2 Anschluss des Signalgebers                              9  9 3 Anschluss von mehreren Signalgebern pro Signalgeberkreis             9  9 4 Anschluss Steuerstromkreise                            10  9 5 Anschluss Reset         ee 10  9 6 Anschluss Meldekontakt                                10  10  Inbetriebnahme und Funktionspr  fung                 11  11 Fehlerdiaghose  ox ka Rm m san and 11  12  Au  erbetriebnahme und Entsorgung                  11  13  Technische  Daten    ae 235 43  5 
40. nected SENTIR edge must not exceed 25 m    Safety contact bumper SENTIR bumper    A maximum of 5 SENTIR bumper devices can be connected in series  The maximum total length of the SENTIR  bumpers must not exceed 15 m    The length of a SENTIR bumper may be up to 3 m    The total line length of the series connected SENTIR bumpers must not exceed 25 m    Safety contact mat SENTIR mat    A maximum of 10 SENTIR mats can be connected in series  The maximum total surface area must not exceed  10 m2    The size of a SENTIR mat can be up to 1350 x 2350 mm    The total line length of the series connected SENTIR mat must not exceed 25 m     Before connecting the series connected sensors  it is recommended to measure the resistance value of the    wiring  In the case of non operated sensors the resistance must be 8 2 kO   500 Q  If the sensor is operated   the resistance must not exceed 500 Q     Sensor 1 Sensor 2 Sensor  n    gll    2   I      2 ee  2    Fig  1  Interconnecting several sensors  here using the example of the safety contact edge                                                                   9 4 Connection of control circuits    The control circuits to be monitored are to be connected to the STOP 1 and STOP 2 terminals If a redundant  continuation of the switching contacts is not desired  a bridge can be inserted between STOP1 and STOP2     may be connected  The use of different voltage potentials does not correspond to any intended       In the event of any redundant u
41. onformes    L utilisation de facon particuli  re n  cessite un accord du fabricant     5  Exemple d application                         Une surveillance de la s  curit   du profil de s  curit   avec d  clenchement de d  marrage via un bouton de  d  marrage et poursuite s  par  e du circuit de commande  cat  gorie 3 utilisation conforme selon la norme  EN ISO 13849 1     Pour le t  moin de fonctionnement des protections de charge K1 et K2  les contacts ouverts de ces protections  sont engag  s dans le circuit de d  part  RESET     La sortie du relais de signalisation sert    visualiser l   tat de commutation du profil de s  curit      Le sch  ma de connexion est hors tension  Capteur pas actionn      1 G  n  rateur de signal  profil  tapis ou bumper    2 Bouton de d  marrage    28    ELMON classic 41 312   ELMON classic 41 812  Relais de s  curit      6  Aper  u de l appareil  6 1 Mod  les    Etui en polycarbonate avec raccords    vis pour montage en saillie dans un environnement non cl  ment        Mod  le Tension d alimentation       ELMON classic 41 312   230 V 50 60 Hz et 24 V CA CC       ELMON classic 41 812   115 V 50 60 Hz et 24 V CA CC       6 2 Signaux    LED Power  vert   Etat de marche  allum     Message d erreur  donn  e impulsion     ASD ey    Solutions       LED Fault  rouge     metteur de signal actionn    allum     Courant   metteur de signal interrompu   clignote rapidement   Mode d erreur maintenu   clignote lentement     ELMON classic 4   PN  1114 0060 B    
42. rhalb des g  ltigen Wertbereiches       Fehler bei Testung Signaleingang       Ausgangssteuerung Relais gest  rt          Daten  bertragung zwischen Mikrocontroller gest  rt    6 3 Anschlussklemmen    ELMON classic 41 312  Versorgungsspannung 230 V 50 60 Hz  ELMON classic 41 812  Versorgungsspannung 115 V 50 60 Hz          Anschluss Signalgeber       Schaltkontakt Sicherheits Relais 1  Schaltkontakt Sicherheits Relais 2       Schaltkontakt Melderelais       Anschluss manuelle R  cksetzung Wiederanlauf  Taster NO  optional        6 4 DIP Schalter zum Einstellen der Betriebsart  S1  AUX        ON     Automatischer Reset     OFF     Fehlerselbsthaltung     manueller Reset  Werkseinstellung   S2  Reset        ON     Modus Meldeausgang AUX  RLU     OFF     Modus Meldeausgang AUX  RL  Werkseinstellung     7  Betriebsarten    7 1 Sicherheitsausgang    Getrennte oder kombinierte Nutzung der Steuerstromkreise  redundante Weiterf  hrung der Schaltkontakte    Um die Schaltkontakte beider Relais gemeinsam zu benutzen  muss eine Br  cke zwischen den Anschl  ssen  STOP1 und STOP2 gesetzt werden     7 2 Automatischer Reset    1      ON        Nach Beseitigung einer St  rung eines Signalgeberstromkreises oder nach Spannungsausfall gibt das Schalt   ger  t den Ausgang automatisch wieder frei     7 3 Fehlerselbsthaltung   manueller Reset    S1      OFF       Nach Beseitigung einer St  rung im Signalgeberstromkreis oder nach Spannungsausfall gibt das Schaltger  t  den oder die Ausg  nge erst wi
43. s sans  accord pr  alable     25    2     Normes de s  curit   g  n  rales et mesures de protection    Le fabricant et l utilisateur du site de la machine o   l on utilise le dispositif de s  curit   sont responsables  de d  terminer et respecter toutes les normes et r  gles de s  curit   selon leur propre responsabilit       Le dispositif de protection garantit  en connexion avec la commande ci dessus une s  curit   fonctionnelle  mais pas la s  curit   de l ensemble du site de la machine  Avant d utiliser l appareil  il est n  cessaire  d   valuer la s  curit   de l ensemble du site de la machine selon la directive de la machine 2006 42 EG  ou selon la norme de produit correspondante     Le mode d emploi doit toujours se trouver sur les lieux d utilisation du dispositif de protection  Il doit    tre lu    fond et utilis   par chaque personne qui est concern  e par l utilisation  l entretien ou la main   tenance du dispositif de protection     L installation et la mise en service du dispositif de protection ne peuvent   tre effectu  es que par la  ressource d  di  e connaissant bien ce mode d emploi et les prescriptions en vigueur sur la s  curit   au  travail et la pr  vention des accidents  Les indications dans ce guide doivent absolument   tre suivies et  respect  es     Les travaux   lectriques ne peuvent   tre effectu  s que par des   lectriciens  Les r  gles de s  curit   du  g  nie   lectrique et du syndicat professionnel doivent   tre respect  es     Pour effectuer d
44. schlie  lich f  r den gewerblichen Gebrauch  B2B  vorgesehen   Nach Nutzungsbeendigung sind die Produkte gem  f allen   rtlichen  regionalen und nationalen Vorschriften  zu entsorgen  ASO nimmt die Produkte auch gern zur  ck und entsorgt diese ordnungsgem         11    13  Technische Daten    Versorgungsspannung    ELMON classic 41 312  230 V AC 50 60 Hz Nominalwert    Netzspannung    Anschlusswiderstand Signalgeber      82kQ    RNom       ELMON classic 41 812  115 V AC 50 60 Hz  Typ X   24 V AC DC  10    2 2 VA 230 V AC  oder 115 V    1 5 W 24 V DC   1 2 VA 24 V AC    oberer Schaltwert       Netzanschlussart  unterer Schaltwert       Kleinspannung UE       Leistungsaufnahme   PNetz_max       PE_max             PE_max    Sicherheitsrelais Melderelais    Nennstrom DC 3     30 V DC     Max  Schaltstrom          Rao   gt 12 0kQ    2     30 V DC   1A  230 V AC        Nennstrom AC 1 A  230 V AC        Mechanische Lebensdauer     gt  105 Bet  tigungen       Mechanische Lebensdauer  gt 10   Bet  tigungen    Betriebsart RL   Einschaltverz  gerung       Ausschaltverz  gerung dis    0 5 Sek         Reaktionszeit  Betriebsart RL     Einschaltdauer          500 ms  Power on 700ms     AC 15  230V AC  1A  550000 Op    DC 13  30V DC  3A  120000 Op      Einschaltverz  gerung       Gebrauchskategorie          der Bet  tigung des Signalgebers     Geh  use ABS  transparenter Deckel     Polycarbonat        3 Sek     Bei der RLU Version schaltet das Melderelais synchron zu    120       Abmessunge
45. se of the switching contacts only voltages with the same potential  use within specifications     Depending on the nominal current  the control circuits are to be protected by a corresponding fuse or the  nominal current on the control circuits must be limited to the maximum value by means of other measures     9 5 Connection Reset    For the operating mode    manual reset    the necessary reset switch must be connected to the RESET terminals     9 6 Connection of signaling contact    The signaling AUX contact only serves as an auxiliary contact  signaling  display etc   and must not be inte   grated into the safety circuit     21    10  Commissioning and function testing    After a corresponding connection of all electrical connections and switching on the supply voltage  the  system   machine must be checked for correct functionality    After successful commissioning  the safety STOP1 and STOP2 outputs are driven  relay contacts  closed     An operation of the signal transmitter causes an opening of the relay contacts    The signaling relay  AUX connection  switches in accordance with the present DIP switch position  This is  indicated by means of the yellow AUX LED    The safety system must be inspected by competent specialists at suitable intervals  The check must be  documented in a way that allows it to be traced at any time  The requirements of the system   machine  manufacturer are to be taken into account and observed     11  Fault diagnosis    If the supply voltage 
46. t nicht oder falsch angeschlossen        Gr  ne LED Interner Fehler wird durch e r    Power Siehe     Signalanzeigen    blinkt zyklisch  Pulsausgabe  Anzahl Pulse angezeigt        Rote LED     Anschl  sse der entsprechenden Signalgeber   berpr  fen  Der entsprechende Signalgeber S GE s  Fault T RU  abgequetschte Zuleitungen  br  chige Zuleitungen etc    wird als betatigt erkannt  3 S    leuchtet   Signalgeber   berpr  fen         Rote LED Signalgeberkreis unterbrochen   Signalgeber nicht angeschlossen   Fault  blinkt schnell fehlerhaft angeschlossen  oder defekt      Anschl  sse der entsprechenden Signalgeber   berpr  fen   abgequetschte Zuleitungen  br  chige Zuleitungen etc      Signalgeber   berpr  fen         Rote LED  Fault Fehlerselbsthaltung Manuellen Reset ausf  hren  blinkt langsam          Liegt der Fehler nicht in der Verdrahtung  kann die Funktion der Elektronik durch Belegen des entspre   chenden Kontaktleisten Eingangs am Schaltger  t mit einem 8 2 kO Widerstand   berpr  ft werden   Arbeitet danach die Elektronik einwandfrei  muss der Signalgeber mit einem Widerstandsmessgerat    berpr  ft werden  Hierf  r muss die Verbindung des Signalgebers zum Schaltger  t aufgetrennt und mit  einem Widerstandsmessger  t verbunden werden  Bei unbet  tigtem Signalgeber muss der Widerstand  8 2 kO  500 O betragen  Ist der Signalgeber bet  tigt  darf der Widerstand 500 O nicht   berschreiten     12  Au  erbetriebnahme und Entsorgung    Die von ASO hergestellten Produkte sind aus
47. tion des deux relais  il faut   tablir un pont entre les  connexions STOP1 et STOP2     7 2 R  initialisation automatique   S1      ON        Apr  s avoir r  solu une panne d un circuit de   metteur de signal ou apr  s une panne de courant  l appareil de  commutation lib  re automatiquement la sortie     7 3 Enclenchement d erreur   r  initialisation manuelle    S1      OFF       Apres avoir r  solu une panne d un circuit de   metteur de signal ou apr  s une panne de courant  l appareil  de commutation lib  re les sorties seulement apr  s que les contacts RESET  500 ms apr  s l   limination de    la perturbation  soient ferm  s par un bouton  Un red  marrage automatique est donc exclu  Un pontage  durable des contacts RESET ne provoque pas un reboot automatique     7 4 Sortie de signal    action instantan  e  RLU  Eu   S2      ON     Output       Dans ce mode de fonctionnement  la sortie de signal  AUX est activee instantanement quand une erreur  quelconque sur le canal correspondant est signal  e  La  sortie est toujours inactive quand l appareil commuta   teur est d  connect   du courant  Sortie de s  curit    symbolique   Signal de sortie  symbolique           Aux  Relay       7 5 Signal de sortie ralenti  RL              Output   S2      OFF      Dans ce mode de fonctionnement  le signal de sortie  AUX est ralenti de 0 5 seconde et reste donc pendant Aux  Relay             max  3 secondes actif quand une erreur est signal  e        Sortie de s  curit    symbolique   Signa
48. tput  zu ecu REA e a ORA ELE A 19  7 2  Automaticreset    ms unes ae ordeum e RP RUE ae Ee 19  7 3  Faultself retaining  manual reset                          19  7 4 Signaling output without any delay  RLU                      19  7 5 Signaling output delayed  RL                             19  8  Mechanical mounting                          20  9  Electrical connection                           20  9 1 Supply voltage                                     20  9 2     Connection Of sensor 2 42 8 2 au de donne Ra beatae da dt 20  9 3 Connection of multiple sensors per sensor circuit                  20  9 4 Connection of control circuits                             21  9 5    Connection Reset  ee ENEE Rr m ee a BERE nn 21  9 6 Connection of signaling contact                           21  10  Commissioning and function testing                   22  11 Fault diagnosis  ss momo komo m ae wae EE 22  12  Decommissioning and disposal                      22  13  Technical data     4  244 EE E 248 4 Xn OXON 23  14  EC Declaration of Conformity                       24    All rights reserved to implement technical and operationally relevant changes of the  products and devices shown in this documentation at any time without prior notice     14    ELMON classic 41 312   ELMON classic 41 812  Safety Relais    2  General safety regulations and protection measures    e The manufacturer and user of the system machine on which the protection system is used are responsible  for coordinating an
49. uand une poursuite redondante des contacts de connexion n est pas souhait  e  on peut   tablir un pont  entre STOP 1 et STOP 2     En cas d utilisation redondante des contacts de connexion  on peut seulement connecter des  tensions    potentiel identique  L utilisation de divers potentiels de tension n est pas conforme  aux regles d utilisation     Les circuits de c  blage   lectrique doivent   tre prot  g  s du courant de base avec le fusible correspondant  ou le courant de base sur les circuits de c  blage   lectrique doit   tre limit   par d autres mesures    la valeur  maximale     9 5 Connexion r  initialisation    Pour le mode de fonctionnement    r  initialisation manuelle     il faut connecter le connecteur de r  initiali   sation aux bornes RESET     9 6 Connexion contact de signalisation    Le contact de signalisation AUX ne sert que comme contact d aide  signalisation  affichage  etc   et il ne peut    tre int  gr   dans le circuit   lectrique de s  curit       32    ELMON classic 41 312   ELMON classic 41 812  Relais de s  curit      10  Mise en service et essai de fonction    Apr  s la connexion correspondante de toutes les connexions   lectriques et l allumage de la tension  d alimentation  il faut v  rifier que le site la machine fonctionne correctement    Apr  s la mise en service r  ussie  il faut allumer les sorties de s  curit   STOP1 et STOP2  contacts relais     ferm  s      En actionnant le   metteur de signal  on ouvre les contacts relais    Le relais d
50. y means of an ohmmeter  In the  case of a non operated sensor the resistance must be 8 2 kO   500 Q  If the sensor is operated  the  resistance must not exceed 500 Q     12  Decommissioning and disposal    The products manufactured by ASO are exclusively intended for commercial use  B2B   At the end of use  the  products must be disposed of according to all local  regional and national regulations  ASO is also happy to  take back the products and disposes of them properly     22    ELMON classic 41 312   ELMON classic 41 812    Safety Relais    13  Technical data    Supply voltage    Mains voltage    Terminating resistor     sensor    ELMON classic 41 312  230 V AC 50 60 Hz Nominal value       ELMON classic 41 812  115 V AC 50 60 Hz       Supply type  Low voltage UE    Upper switching    Typ X point       24 V AC DC  10  Lower switching       Power consumption    PNetz_max    2 2 VA 230 V AC  oder 115 V  point       PE_max    1 5 W 24 V DC          Safety relay    Nominal current DC    PE_max       1 2 VA 24 V AC       Auxiliary relay    3A  30 V DC  max  switching current       Nominal current AC          2 A  30 V DC   1 A  230 V AC        1A  230 V AC        Mechanical life time    Mechanical life time     gt  105 actuations        gt 10   actuations       Switch off delay   reaction time     Operating mode RL       12ms Switch on delay    0 5 Sek           Switch on delay    Operating mode RL   Switch on duration       500 ms  Power on 700ms        Utilization category   
    