1. Logic i Go OUT 100 REL1 Functional circuit diagram 16 ELMON classic 41 312 ELMON classic 41 812 Safety Relais 4 Intended use The switching device can only fulfill its safety relevant task if it is used as intended within specifications The intended use of the switching device is the use as a protection system in connection with safety contact mats safety bumpers and safety contact edges with 8 2 kO resistance for steady state current monitoring A different use or any use going beyond the intended use is not within specifications The manufacturer does not accept any liability for any damage arising from use not within specifications Any use for special applications requires prior release by the manufacturer 5 Application example Safety orientated monitoring of a safety contact strip with start release via release pushbutton and separate continuation of the control circuits category 3 compliant application according to EN ISO 13849 1 In order to check the functionality of the load breaking K1 and K2 relays the break contacts of these contactors are integrated into the start circuit RESET The signaling relay output is used to visualize the switching state of the safety contact edge Circuit diagram in voltage free state Sensor not operated 1 Sensor edge mat or bumper 2 Release key 17
2. Housing Dimensions HxWxD Housing Housing incl cable clamps Protection type with M16 cable clamps with M16 blanking plug Protection class Contamination degree Overvoltage category Rated insulation voltage Rated impulse voltage resistance Weight Temperature range Connection cable cross section Certifications ELMON classic 41 312 41 812 AC 15 230V AC 1A 550000 Op DC 13 30V DC 3A 120000 Op to the operation of the sensor ABS transparent lid polycarbonate 3 Sek With the RLU version the signal relay switches synchronously 120 120 x 80 x 56 mm 120 x 102 x 56 mm IP65 Ul 250V 4 00 kV 350g 20 C to 55 C single or fine stranded cable 0 75 1 5 mm EN ISO 13849 1 2008 Category 3 PL e MTTFd 236 years DC 99 EN 62061 2013 SILCL 3 PFHd 8 59E 09 1 h Electronics MTTFd 625 years DC 99 Electromechanics EC type examination no 44 205 13176203 Certificate no B10d 2000000 MTTFd 380 years DC 99 Nop 52560 Test report no 44 780 13 xxxxxx 3512 6372 14 EC declaration of conformity We hereby declare that the following products of the series ELMON rail 41 312 article number 1114 0060 format serial number yymmnnnnn ELMON rail 41 812 article number 1114 0130 format serial number yymmnnnnn Safety switching device for the combination of switching strips switching mats and switching bumpers for avoiding
3. 55 C Section des c bles c ble monobrin ou brins fins 0 75 1 5 mm Homologations ELMON classic 41 312 41 812 EN ISO 13849 1 2008 cat gorie 3 PL e MTTFd 236 ann es DC 99 EN 62061 2013 SILCL 3 PFHd 8 59E 09 1 h de Electronique MTTFd 625 ann es DC 99 TUV NORD T V NORD CERT GmbH B10d 2000000 MTTFd 380 ann es DC 99 Nop 52560 Electrom canique Certificat d examen Certificat n Rapport de test n CE de mod le type n 44 780 13 xxxxxx 3512 6372 44 205 13176203 34 ELMON classic 41 312 ELMON classic 41 812 Relais de s curit 14 D claration de conformit CE Par la pr sente nous d clarons que les produits mentionn s ci dessous de la gamme ELMON rail 41 312 Num ro d article 1114 0060 Format Num ro de s rie yymmnnnnn ELMON rail 41 812 Num ro d article 1114 0130 Format Num ro de s rie yymmnnnnn appareil de commutation s curis en combinaison avec des barres de commutation des tapis de commutation et des pare chocs pour viter les dangers aux points de coin cement et de cisaillement sur la base de la conception et du mode de fabrication ainsi que dans un mod le que nous avons mis nous m me en circulation correspond aux exigences de s curit et de sant relatives des directives de la CEE suivantes Directive machines 2006 42 CEE EN ISO 13849 1 2008 EN ISO 13849 2 2013 EN 62061 2013 09 EN 60947 5 1 2010 04 EN 61000 6 2 2005
4. Das Ger t kann in Haushaltsumgebung und Industrieumgebung bis zu einer H he von 2000m A ber NN verwendet werden Das Ger t darf nicht in Bereichen mit starken Temperaturwechseln betrieben werden pce mec es uo Ho 13 ELMON classic 41 312 230 V AC TO 14 ELMON classic 41 812 115 V AC DIL Switch i fo 11 Manual 79 I Reset lo12 24 V AC DC Reset Mode 80 Los TT OUT REL1 U Op 948 rel e c O2 Sensor logic 03 i ECH i OUT 100 H REL1 04 Funktionsschaltbild 4 Bestimmungsgem e Verwendung Das Schaltger t kann seine sicherheitsrelevante Aufgabe nur erf llen wenn es bestimmungsgem f eingesetzt wird Die bestimmungsgem e Verwendung des Schaltger tes ist der Einsatz als Schutzeinrichtung in Verbindung mit Sicherheitskontaktmatten Sicherheitsbumpern und Sicherheitskontaktleisten mit 8 2 kO Widerstand zur Ruhestrom berwachung Ein anderer oder dar ber hinausgehender Einsatz ist nicht bestimmungsgem F r Sch den die aus nicht bestimmungsgem en Verwendungen entstehen bernimmt der Hersteller keine Haftung Der Einsatz bei Sonderanwendungen bedarf einer Freigabe vom Hersteller 5 Anwendungsbeispiele Sicherheitsgerichtet
5. LED AUX jaune Sortie de signalisation allumee S il n y a pas de message d erreur l tat de marche est montr via la LED Power S il y a un message d erreur le nombre d impulsions indique l erreur Impulsion Message d erreur Alimentation en courant en dehors de la zone de valeur valide Erreur lors du test de l entr e du signal Commande de sortie du relais en panne Transfert de donn es entre microcontr leurs en panne 6 3 Bornes de connexion L1N ELMON classic 41 312 tension d alimentation 230 V 50 60 Hz ELMON classic 41 812 tension d alimentation 115 V 50 60 Hz 24V AC DC tension d alimentation 24 V CA CC Connexion metteur de signal Contact de connexion relais de s curit 1 Contact de connexion relais de s curit 2 Contact de connexion relais de signal Connexion manuelle r initialisation red marrage touche NO en option 29 6 4 Commutateur DIP pour r glage mode de fonctionnement S1 AUX ON r initialisation automatique OFF enclenchement erreur r initialisation manuelle r glage d usine S2 Reset ON mode sortie de signalisation AUX RLU OFF mode sortie de signalisation AUX RL r glage d usine 7 Modes de fonctionnement 7 1 Sortie de s curit Utilisation s par e ou combin e du circuit de commande poursuite redondante des contacts de commu tation Pour utiliser ensemble les contacts de commuta
6. tat de surveillance du g n rateur de signal et la tension de travail tablie sont affich s par LED Quand il y a un message d erreur toutes les sorties de s curit sont inactives L appareil peut tre utilis dans un foyer et en milieu industriel jusqu une hauteur de 2000m via NN L appareil ne peut pas tre utilis dans des zones forte temp rature Lo13 ELMON classic 41 312 230 V AC 0 14 ELMON classic 41 812 115 V AC DIL Switch O11 012 24 V AC DC Manual 79 Reset Reset Mode 80 NN 9 OUT i it RELI U 706 Fo1 cO j 02 901 k Sensor j 9 Logic o ch FFE93 our 100 H REL1 O4 Fonction sch ma des connexions 27 4 Utilisation conforme L appareil de commutation ne peut accomplir sa t che de s curit que s il est utilis de facon conforme L utilisation conforme de l appareil de commutation c est l utilisation comme dispositif de protection en rapport avec les tapis de s curit les bumpers de s curit et les profils des contacts de s curit avec une r sistance de 8 2 kQ pour la surveillance du courant de repos Une autre utilisation n est pas conforme Le fabricant n est pas responsable des dommages qui proviennent d utilisations non c
7. 6 Device overview 6 1 Versions Polycarbonate housing with boltings for surface installation in a rough environment Version Supply voltage ELMON classic 41 312 230 V 50 60 Hz und 24 V AC DC ELMON classic 41 812 115 V 50 60 Hz und 24 V AC DC 6 2 Signal indicators 111111 Ran ELMON classic 41 312 LED Power green Operating state on Fault alarm pulse LED Fault red Sensor operated on Sensor power circuit interrupted fast flashing Fault self retaining slow flashing LED AUX yellow Signal output switched If there is no fault alarm the operating state is shown via the Power LED on When a fault alarm is issued the number of pulses output indicates the fault Fault alarm Voltage supply outside the valid value range Fault when testing signal input Output control relay faulty Data transmission between micro controllers faulty 6 3 Connection terminals ELMON classic 41 312 Supply voltage 230 V 50 60 Hz ELMON classic 41 812 Supply voltage 115 V 50 60 Hz 24V AC DC Supply voltage 24 V AC DC Connection sensor Switching contact safety relay 1 Switching contact safety relay 2 Switching contact signaling relay Connection manual reset re start key NO optional 18 ELMON classic 41 312 ELMON classic 41 812 Safety Relais 6 4 DIP switch for configuring the operating mode S1 AUX ON Automatic reset OFF Fau
8. EN 61000 6 3 2007 Contr le CE de la conception Notified Body 0044 T V NORD CERT GmbH Langemarckstra e 20 D 45141 Essen Attestation d examen CE N 44 205 13176203 Cette d claration de conformit ne d gage pas le constructeur fabricant de son obligation d assurer la conformit de l enti ret de la machine sur laquelle on a plac ce produit conform ment la directive CE Fabricant et fond de pouvoir ASO Antriebs und Steuerungstechnik GmbH Hansastra e 52 D 59557 Lippstadt 35 ELMON Sicherheitsschltgerat Safety Relais Relais de s curit Deutsch English Francais 36 11 DB 18 001 Betriebsanleitung Rev 01 Technische Anderungen vorbehalten F r Irrt mer und Druckfehler kann keine Haftung bernommen werden Diese Betriebsanleitung ist f r folgende Versionsst nde g ltig von V 1 0 bis V 1 0 11 DB 18 001 Operating Manual Rev 01 Subject to technical modifications No liability can be assumed for errors or misprints This operating manual is valid for the following versions from V 1 0 to V 1 0 11 DB 18 001 Manuel d utilisation R v 01 Sous r serve de modifications techniques Nous d clinons toute responsabilit en cas d erreurs et de fautes d impression Ce mode d emploi n est valable que pour les versions suivantes deV1 0aV1 0 Antriebs und Steuerungstechnik Safet y Hansastra e 52 e D 59557 Lippstadt TR CERT Solutions Tel 49 2941 9793 0 Fax 49 2941 97
9. Elektrofachkr ften durchgef hrt werden Sicherheitsvorschriften der Elektrotechnik und der Berufsgenossenschaft sind zu beachten Bei Arbeiten am Schaltger t ist dieses spannungsfrei zu schalten und auf Spannungsfreiheit zu pr fen und gegen Wiedereinschalten zu sichern Werden die potentialfreien Anschl sse der Sicherheitsschaltkontakte mit einer gef hrlichen Spannung fremdgespeist ist sicherzustellen dass diese bei Arbeiten an dem Schaltger t ebenfalls abgeschaltet werden Das Schaltger t enth lt keine vom Anwender zu wartende Bauteile Durch eigenm chtige Umbauten bzw Reparaturen am Schaltger t erlischt jegliche Gew hrleistung und Haftung des Herstellers Hilfsausg nge d rfen keine sicherheitsgerichteten Funktionen ausf hren Sie sind nicht einfehlersicher und werden auch nicht durch Testung berpr ft F r die normenkonforme Auslegung des Sicherheitssystems muss die Anlage von Sachkundigen AN in geeigneten Zeitabstanden auf korrekte Funktion gepr ft werden Die Pr fung muss in jederzeit nachvollziehbarer Weise dokumentiert werden Bei Nichtbeachtung oder vors tzlichem Missbrauch entf llt die Haftung des Herstellers ELMON classic 41 312 ELMON classic 41 812 Sicherheitsschaltgerat 3 Allgemeines und Funktionsbeschreibung Das Schaltgerat ELMON classic 41 312 41 812 dient zur Auswertung von Signalgebern wie Sicherheitskontakt matten Sicherheitskontaktleisten und Sicherheitsbumpern zur Absicherung von Quetsc
10. Reden Wi a dat CER ak 29 6 4 Commutateur DIP pour r glage mode de fonctionnement 30 7 Modes de fonctionnement 30 7 1 Sortie de s Curit 422 48 6 ub RH RR Tu gd 30 7 2 R initialisation automatique 30 7 3 Enclenchement d erreur r initialisation manuelle 30 7 4 Sortie de signal action instantan e RLU 30 7 5 Signal de sortie ralenti RL 30 8 Fixation m canique 31 9 Connexion lectrique 31 9 1 Tension d alimentation 31 9 2 Connexion du metteur de signal 31 9 3 Connexion de plusieurs metteurs de signal par circuit de metteur de signal 31 9 4 Connexion circuit de c blage lectrique 32 9 5 Connexion r initialisation 32 9 6 Connexion contact de signalisation 32 10 Mise en service et essai de fonction 33 11 Diagnostic d erreur 33 12 Mise hors tension et recyclage 33 13 Donn es techniques 34 14 D claration de conformit CEE 35 Des modifications techniques et importantes pour le fonctionnement par rapport cette documentation pour les produits et appareils sont toujours interdite
11. Schaltger tes ist beliebig sollte jedoch zum Schutz vor eindringender Feuchtigkeit so montiert werden dass die Kabeleinf hrungen nach unten zeigen 9 Elektrischer Anschluss Der Anschluss an die falschen Klemmen kann das Schaltger t zerst ren Flexible Anschlussleitungen sind gegen Verlagern zu sichern Die Netzzuleitungsadern sind durch Isolierschl uche zus tzlich zu isolieren Leitungen die im Freien oder au erhalb vom Schaltschrank verlegt werden m ssen ent sprechend gesch tzt werden F r den ungesch tzten AuRenbereich darf nur ein entsprechend zugelassenes Kabel verwendet werden zum Beispiel Gummileitung Die in den Technischen Daten angegebenen Grenzwerte f r die Versorgungsspannung und Schaltverm gen des Relais sind zu beachten 9 1 Versorgungsspannung Die Spannungsversorgung kann wahlweise mit Netzspannung 230 V AC 50 60 Hz ELMON rail 41 822 115 V AC 50 60 Hz oder mit Kleinspannung 24 V AC DC erfolgen Bei Versorgung mit 24 V AC DC muss die Spannung den Anforderungen f r Schutzkleinspannung SELV entsprechen Die Versorgungsleitung zum Schaltger t ist mit einer passenden Sicherung zu sch tzen Niemals beide Spannungen gleichzeitig anlegen Die 230 V Versorgungsspannung ist an die Klemmen L1 N anzulegen F r den Betrieb mit 24 V ist die Versorgungsspannung an den Klemmen 24V AC DC anschlie en Bei einer Festinstallation muss eine Trenneinrichtung vorhanden sein zum Beispiel Hauptschalter f r
12. das System Ein Netzstecker ist als Trenneinrichtung ausreichend wenn er frei zug nglich ist 9 2 Anschluss des Signalgebers Der Signalgeber mit einem Abschlusswiderstand von 8 2 kO muss an die Klemmen IN angeschlossen werden 9 3 Anschluss von mehreren Signalgebern pro Signalgeberkreis AN ASO Signalgeber d rfen nicht parallel geschaltet werden An dem Signalgebereingang k nnen ein oder mehrere Signalgeber angeschlossen werden Hierf r werden die einzelnen Signalgeber in Serie geschaltet Bild 1 Sicherheitskontaktleiste SENTIR edge Es k nnen maximal 5 SENTIR edge in Serie geschaltet werden Die maximale Gesamtlange der SENTIR edge darf 100 m nicht berschreiten Die Lange einer SENTIR edge kann bis zu 25 m betragen Die Gesamtleitungslange der in Serie geschalteten SENTIR edge darf 25 m nicht berschreiten Sicherheitskontaktpuffer SENTIR bumper Es k nnen maximal 5 SENTIR bumper in Serie geschaltet werden Die maximale Gesamtl nge der SENTIR bumper darf 15 m nicht berschreiten Die L nge eines SENTIR bumper kann bis zu 3 m betragen Die Gesamtleitungslange der in Serie geschalteten SENTIR bumper darf 25 m nicht berschreiten Sicherheitskontaktmatte SENTIR mat Es k nnen maximal 10 SENTIR mat in Serie geschaltet werden Die maximale Gesamtflache darf 10 m nicht berschreiten Die Gr e einer SENTIR mat kann bis zu 1350 x 2350 mm betragen Die Gesamtleitungslange der in Serie geschalteten SENTIR mat darf 25
13. m nicht berschreiten Vor dem Anschlie en der in Serie geschalteten Signalgeber ist es empfehlenswert den Widerstandswert der Verschaltung auszumessen Bei unbet tigtem Signalgeber muss der Widerstand 8 2 KQ 500 O betragen Ist der Signalgeber bet tigt darf der Widerstand 500 O nicht berschreiten Signalgeber 1 Signalgeber 2 Signalgeber n gll 9 I 2 Mon 2 Bild 1 Verschaltung mehrerer Signalgeber hier am Beispiel Sicherheitskontaktleiste 9 4 Anschluss Steuerstromkreise Die zu berwachenden Steuerstromkreise sind an die Klemmen STOP 1 und STOP 2 anzuschlie en Wenn eine redundante Weiterf hrung der Schaltkontakte nicht gew nscht ist kann eine Br cke zwischen STOP 1 und STOP 2 eingesetzt werden Bei redundanter Verwendung der Schaltkontakte d rfen nur Spannungen mit gleichem Potential angeschlossen werden Die Verwendung von unterschiedlichen Spannungspotentialen entspricht keiner bestimmungsgem en Verwendung Die Steuerstromkreise sind abh ngig vom Nennstrom mit einer entsprechenden Sicherung zu sch tzen oder der Nennstrom auf den Steuerstromkreisen muss durch andere Ma nahmen auf den maximalen Wert begrenzt werden 9 5 Anschluss Reset F r die Betriebsart manueller Reset muss der notwendige Reset Schalter an die Klemmen RESET ange schlossen werden 9 6 Anschluss Meldekontakt Der Meldekontakt AUX dient lediglich als Hilfskonta
14. peut tre de 25 m La longueur maximale des c bles des SENTIR edge monter en s rie ne doit pas d passer 25 m Bumper de s curit SENTIR bumper Il est possible de monter au plus 5 SENTIR bumper en s rie La longueur totale des SENTIR bumper ne doit pas d passer 15 m La longueur max d un SENTIR bumper peut tre de 3 m La longueur maximale des c bles des SENTIR bumper monter en s rie ne doit pas d passer 25 m Tapis de s curit SENTIR mat Il est possible de monter au plus 10 SENTIR mat en s rie La surface totale ne doit pas d passer 10 m2 Dimensions maximales d un SENTIR mat est de 1350 x 2350 mm La longueur maximale des c bles des SENTIR mat monteren s rie ne doit pas d passer 25 m Avant le raccordement des metteurs de signaux en s rie il est recommand de mesurer la valeur ohmique du c blage Quand l metteur de signaux est au repos la r sistance doit tre de 8 2 KQ 500 Q Si l metteur de signaux est actionn e la r sistance ne doit pas exc der 500 Q metteur de signaux 1 metteur de signaux 2 metteur de signaux n o 5 i 1 zx ge 2 Figure 1 connexion de plusieurs metteurs de signal ici par exemple sur le profil de contact de s curit 9 4 Connexion circuit de c blage lectrique Les circuits de c blage lectrique surveiller doivent tre connect s sur les bornes STOP 1 et STOP 2 Q
15. tre v rifi es cables cras s cables cassants non raccord etc mal raccord ou d fectueux v rifier le metteur de signal La LED rouge Fault clignote rapidement La LED rouge Fault R serve d erreur effectuer une r initialisation manuelle clignote lentement Si l erreur n est pas due au c blage on peut tester la fonctionnalit de l lectronique en programmant l entr e du metteur de signal sur l appareil commutateur avec une r sistance de 8 2 kO Si ensuite l lectronique fonctionne parfaitement le metteur de signal doit tre test avec un appareil de mesure de r sistance Pour ce faire la connexion du metteur de signal doit tre enlev e de l appareil de commutation et tre connect e un appareil de mesure de r sistance Si le metteur de signal n est pas enclench la r sistance doit tre de 8 2 KQ 500 Q Si le metteur de signal est enclench la r sistance ne peut d passer 500 O 12 Mise hors tension et recyclage Les produits fabriqu s par ASO ne sont pr vus que pour un usage industriel B2B Apr s la fin de l utilisation les produits doivent tre recycl s selon les normes locales r gionales et nationales ASO reprend volontiers les produits et les recycle comme il se doit 33 13 Donn es techniques R sistance terminale de Tension d alimentation l metteur de signaux ELMON classic 41 312 230 V CA 50 60 Hz valeur nominale eset elu meseci Ure LE MON
16. 238 23 8 E Xn E XU 12 14 EG Konformit tserkl rung 13 Technische und betriebsrelevante nderungen zu den in dieser Dokumentation aufgef hrten Produkten und Ger ten sind jederzeit auch ohne Vorank ndigung vor behalten 2 Allgemeine Sicherheitsbestimmungen und Schutzmafinahmen Hersteller und Benutzer der Anlage Maschine an der die Schutzeinrichtung verwendet wird sind daf r verantwortlich alle geltenden Sicherheitsvorschriften und regeln in eigener Verantwortung abzustimmen und einzuhalten Die Schutzeinrichtung garantiert in Verbindung mit der bergeordneten Steuerung eine funktionale Sicherheit nicht aber die Sicherheit der gesamten Anlage Maschine Vor dem Einsatz des Ger tes ist deshalb eine Sicherheitsbetrachtung der gesamten Anlage Maschine nach der Maschinenrichtlinie 2006 42 EG oder nach entsprechender Produktnorm notwendig Die Betriebssanleitung muss st ndig am Einsatzort der Schutzeinrichtung verf gbar sein Sie ist von jeder Person die mit der Bedienung Wartung oder Instandhaltung der Schutzeinrichtung beauftragt wird gr ndlich zu lesen und anzuwenden Die Installation und Inbetriebnahme der Schutzeinrichtung darf nur durch Fachpersonal erfolgen die mit dieser Betriebsanleitung und den geltenden Vorschriften ber Arbeitssicherheit und Unfallverh tung vertraut sind Die Hinweise in dieser Anleitung sind unbedingt zu beachten und einzuhalten Elektrische Arbeiten d rfen nur von
17. 93 299 ISO 9001 www asosafety com e e mail info asosafety com
18. ELMON classic 41 312 ELMON classic 41 812 Betriebsanleitung Operating Manual Manuel d utilisation bergabedokumentation Documentation Documentation de datation Anlagenbeschreibung Description Description du systeme Anlagenart Type of plant Sorte du syst me Hersteller Manufacturer Fabricant Seriennummer Serial number Num ro de s rie Datum der Inbetriebnahme Commissioning date Date de mise en marche Aufstellort Site of installation Lieu de montage Verwendete Steuerung Control unit Commande utilis e Zusatzkomponenten Additional components Composants suppl mentaires Funktionspr fung Functional test Contr le de fonction Sicherheitssensoren reagieren auf Bet tigung Safety sensor response to actuation Le senseur de s curit r agit l actionnement Sicherheitssensoren reagieren auf Zuleitungsunterbrechung Safety sensor response to supply line interruption Le senseur de s curit r agit l interruption de l alimentation Name der ausf hrenden Firma Owner Nom de la soci t ex cutrice Name des Installateurs Installer Nom de l installateur Datum Date Date Unterschrift Signature Signature ELMON classic 41 312 ELMON classic 41 812 Sicherheitsschaltger t 1 Inhaltsverzeichnis 1 Inhaltsverzeichnis 3 2 Allgemeine Sicherheitsbestimmungen und Schutzma nahmen 4 3 Allgemeines u
19. OFF In this operating mode the AUX signaling output is Aux Relay activated with a delay of 0 5 seconds and then remains active for amaximum of 3 seconds if a fault is signaled Safety output symbolic Signaling output symbolic 19 8 Mechanical mounting Polycarbonate housing with boltings for surface installation in a rough environment The switching device must be mounted properly in a suitable mounting location After the A lid has been removed the casing can be mounted by means of four bolts e Do not install in the immediate vicinity of an intense heat source e The unit must not be operated in areas with major temperature changes The switching unit can be installed in any position but in order to protect against any ingress of humidity it should be fitted such that the cable entries point downwards 9 Electrical connection The switching unit can be destroyed by connection to the incorrect terminals Flexible connection leads must be secured against any shifting The mains infeed wires must be additionally insulated by means of insulation tubes Lines that are routed in the open air or outside the switch cabinet must be protected accor dingly For the unprotected external area only an appropriately approved cable may be used for example rubber lead The limit values stated in the Technical Data for the supply voltage and the switching capability of the relay must be observed 9 1 Supply vo
20. ailable An operation of the sensor causes a reaction of the signal output in accordance with the DIP switch configuration The signal output must not execute any safety orientated functions It is not fail safe and not checked by testing either The switching device has been designed and type approved in accordance with EN ISO 13849 1 Safety related parts of control systems for category 3 Performance Level e For compliance with category 3 the safety output is set up redundantly with two independent switching elements In addition the device has been type approved according to EN 62061 Functional safety of safety related electrical electronic and programmable electronic control systems and can meet a safety function up to SIL3 The monitoring state of the sensor and the applied operating voltage are indicated by LED If there is a fault alarm all safety outputs are inactive an altitude of 2000m above mean sea level The unit must not be operated in areas with major The unit can be used in a household environment as well as in an industrial environment up to A temperature changes 11013 ELMON classic 41 312 230 V AC HO 14 ELMON classic 41 812 115 V AC DIL Switch ki i 1 Manual 79 Reset 1012 24V AC DC Reset 80 Mode Los OUT H f RELL U Op 9ol1 e e Sensor 9
21. an external source it must be ensured that these are also switched off when working on the switching device e The switching device does not contain any components that the user must service Any warranty or liability on the part of the manufacturer is forfeited in the event of any unauthorized modifications or repairs to the switching device e Auxiliary outputs must not execute any safety orientated functions They are not fail safe and are not checked by testing either The system must be checked for correct function in suitable intervals by qualified persons for the AN standard conform design of the safety system The check must be documented in a way that allows it to be traced at any time In the case of non compliance or deliberate abuse the manufacturer s liability will cease 15 3 General and function description The ELMON classic 41 312 switching device is used to evaluate sensors such as safety contact mats safety contact strips and safety bumpers for securing crush and shear locations An ASO sensor can be connected to the switching device The steady state current monitoring of the sensor is made possible by an integrated terminating resistor in the sensor If the desired steady state current flows the safety relays are driven and the switching contacts closed If the sensor is operated or the sensor circuit is interrupted the relay switching contacts open A signal output with potential free switching contacts is av
22. classic 41 812 115 V CA 50 60 Hz valeur sup rieure Type de connexion r seau Type X de commutation Basse tension UE 24 V CA CC 10 Alerter Puissance absorb e Ppr seau_max 2 2 VA 230 V CA ou 115 V de commutation PE max 1 5 W 24 V CC PE max 1 2 VA 24 V CA Relais de s curit Relais de signalisation Courant nominal CC 3A 30V CC Max courant de 2 A 30 V CC Courant nominal CA 1A 230 V CA commutation EE Dur e de vie m canique gt 10 actionnements Dur e de vie m canique gt 10 actionnements Mode de fonctionnement RL ub Retard l enclenchement temps de r action Mode de fonctionnement RL Temps de d connexion 500 ms Power on 700ms Dur e d enclenchement AC 15 230V CA 1A 550000 Op Pour la version RLU le relais de signalisation s allume en DC 13 30V CC 3A 120000 Op m me temps que l enclenchement du metteur de signal Retard au d clenchement 0 5 Sek 12ms Cat gorie d utilisation Bo tier AB couvercle transparent polycarbonate ra 120 Dimensions HxLxP Bo tier 120 x 80 x 56 mm Bo tier presse toupe incl 120 x 102 x 56 mm Indice de protection avec presse toupe M16 IP65 avec bouchons M16 IP54 Classe de protection Il isolation de protection Niveau de pollution 2 Cat gorie de surtension Hl Tension d isolation calcul e 250V Tension nominale d essai 4 00 kV Poids 350g Zone de temp rature 20 C
23. d adhering to all applicable safety rules and regulations under their own responsibility e The protection system guarantees functional safety in combination with the superordinate control system but not the safety of the entire system machine Thus a safety review of the entire system machine in accordance with machine directive 2006 42 EC or relevant product standards is necessary prior to use of the device e The operating instructions must be permanently available at the operating location of the protection device They must be thoroughly read and applied by every person who is tasked with the operation maintenance or repair of the protection device e The installation and start up of the protection device may only be conducted by specialized personnel who are familiar with these operating instructions and the applicable regulations on job safety and accident prevention The instructions in these operating instructions must be followed and adhered to unconditionally e Electrical work may only be carried out by skilled electricians Safety regulations for electrical engineering and from the professional association must be followed e In case work has to be carried out on the switching device it must be switched to a voltage free position and checked for freedom from any voltage and secured against being switched back on again e If the potential free connections of the safety switching contacts are supplied with a hazardous voltage from
24. e berwachung von einer Sicherheitskontaktleiste mit Startfreigabe ber Freigabetaster und getrennter Weiterf hrung der Steuerstromkreise Kategorie 3 konforme Anwendung nach EN ISO 13849 1 Zur Funktionskontrolle der Lastsch tze K1 und K2 werden die Offnerkontakte dieser Sch tze in den Start Kreis RESET eingebunden Der Melderelais Ausgang dient zur Visualisierung des Schaltzustandes der Sicherheitskontaktleiste Schaltbild im spannungslosen Zustand Sensor nicht bet tigt 1 Signalgeber Leiste Matte oder Bumper 2 Freigabetaster 6 ELMON classic 41 312 ELMON classic 41 812 Sicherheitsschaltger t 6 Ger te bersicht 6 1 Ausf hrungen Polycarbonat Geh use mit Verschraubungen f r Aufputzmontage in rauer Umgebung Ausf hrung Versorgungsspannung ELMON classic 41 312 230 V 50 60 Hz und 24 V AC DC ELMON classic 41 812 115 V 50 60 Hz und 24 V AC DC 6 2 Signalanzeigen LED Power gr n Betriebszustand an Fehlermeldung Pulsausgabe LED Fault rot Signalgeber bet tigt an Signalgeberstromkreis unterbrochen blinkt schnell Fehlerselbsthaltung blinkt langsam LED AUX gelb Meldeausgang geschaltet n5 Safety WM Solutions ELMON classic 4 PN 1114 0060 M Liegt keine Fehlermeldung vor so wird Uber die LED Power der Betriebszustand angezeigt an Bei Ausgabe einer Fehlermeldung gibt die Anzahl der ausgegebenen Pulse den Fehler an Fehlermeldung 1 Spannungsversorgung au e
25. e cisaillement Sur l appareil de commutation on peut fixer un g n rateur de signal ASO La surveillance du courant de repos du g n rateur de signal est rendue possible gr ce une r sistance de terminaison int gr e dans le g n rateur de signal Si le courant au repos du d bit circule les relais de s curit sont cingl s et le contact d allumage est ferm Si l on actionne le g n rateur de signal ou si le circuit du g n rateur de signal est interrompu les contacts d allumage relais s ouvrent Une sortie de signalisation avec des contacts d allumage potentiellement libres est disponible Si l on actionne le g n rateur de contact cela d clenche une r action du signal de sortie qui correspond la configuration du commutateur DIP La sortie de signalisation ne peut effectuer aucune fonction s curis e Ce n est pas s r et cela n a pas t test L appareil de commutation correspond la norme EN ISO 13849 1 pi ces de classification de s curit des contr leurs pour cat 3 Niveau de performance expliqu et homologu Pour la conformit de la cat gorie 3 la sortie de s curit est redondante et construite avec deux l ments de commutation ind pendants En compl ment l appareil a t homologu selon la norme EN 62061 S curit fonctionnelle de syst mes s curis s lectriques lectroniques et de commandes programmables lectroniquement et peut avoir une fonction s curitaire allant jusqu SIL L
26. e signalisation connexion AUX allume la position de l interrupteur DIP disponible Celui ci est affich l aide de LED jaunes AUX Le syst me de s curit doit tre v rifi intervalles r guliers La v rification doit chaque fois tre effectu e de mani re document e Les exigences du fabricant du site de la machine doivent tre prises en compte et respect es 11 Diagnostic d erreur En cas de c blage correct et pose correcte de la tension d alimentation seule la LED verte Power peut tre allum e Si la LED rouge s allume il y a une erreur dans le syst me qui sera limit e l aide des LED mi rm p V rifier les connexions et la tension d alimentation 230 V CA ou 115 V aux bornes L1 N ou 24 V CA CC la borne 24 V AC DC Zone de tol rance 10 La LED verte La tension d alimentation Power manque est trop faible ne s allume pas ou mal connect e La LED verte Power l erreur interne sera affich e clignote de facon cyclique par le nombre d impulsions donn e d impulsion Voir gt signaux les connexions des metteurs de signal correspondants doivent tre v rifi es c bles cras s c bles cassants etc v rifier le metteur de signal La LED rouge Le metteur de signal Fault correspondant est consid r clignote comme enfonc Circuit de metteur de signal les connexions des metteurs de signal correspondants interrompu metteur de signal doivent
27. ebrachten Ausf hrung den einschlagigen grundlegenden Sicherheits und Gesundheitsanforderungen der nach folgenden EG Richtlinien entspricht EG Maschinenrichtlinie 2006 42 EG EN ISO 13849 1 2008 EN ISO 13849 2 2013 EN 62061 2013 09 EN 60947 5 1 2010 04 EN 61000 6 2 2005 EN 61000 6 3 2007 EG Baumusterpr fung Notified Body 0044 T V NORD CERT GmbH Langemarckstra e 20 D 45141 Essen EG Baumusterpr fbescheinigung Nr 44 205 13176203 Diese Konformit tserkl rung entbindet den Konstrukteur Hersteller der Maschine nicht von seiner Pflicht die Konformit t der gesamten Maschine an der dieses Produkt ange bracht wird entsprechend der EG Richtlinie sicherzustellen Hersteller und Dokumentenbevollm chtigter ASO Antriebs und Steuerungstechnik GmbH Hansastra e 52 D 59557 Lippstadt 13 1 Table of Contents 1 Table of Contents 14 2 General safety regulations and protection measures 15 3 General and function description 16 4 Intended user ue ote mo AE tarder 17 5 Application example 17 6 Device overview 18 B l VEVSIONS usos d els de na 18 6 2 Signal indicators duo ore de AS Ge DICERE UY a end 18 6 3 Connection terminals 18 6 4 DIP switch for configuring the operating mode 19 7 Operating modes 19 7 1 Safety ou
28. eder frei wenn die Kontakte RESET 500 ms nach Beseitigung der St rung mit einem Taster geschlossen werden Ein automatisches Wiederanlaufen ist so ausgeschlossen Ein dauerhaftes berbr cken der Kontakte RESET f hrt nicht zu einer automatischen R cksetzung 7 4 Meldeausgang unverz gert RLU mu S2 ON Output In dieser Betriebsart wird der Meldeausgang AUX unverz gert aktiviert wenn ein beliebiger Fehler am entsprechenden Kanal signalisiert wird Der Ausgang ist im stromlosen Zustand des Schaltger tes immer inaktiv ist Sicherheitsausgang symbolisch Meldeausgang symbolisch Aux Relay 7 5 Meldeausgang verz gert RL Output S2 OFF In dieser Betriebsart wird der Meldeausgang AUX um Aux Relay 0 5 Sekunden verz gert aktiviert und bleibt dann f r max 3 Sekunden aktiv wenn ein Fehler signalisiert wird Sicherheitsausgang symbolisch Meldeausgang symbolisch ELMON classic 41 312 ELMON classic 41 812 Sicherheitsschaltger t 8 Mechanische Befestigung Polycarbonat Geh use mit Verschraubungen f r Aufputzmontage in rauer Umgebung e Das Schaltger t ist fachgerecht an einem geeigneten Montageort zu befestigen Nach Entfernen VAN des Deckels kann das Geh use mit vier Schrauben befestigt werden e Nicht in unmittelbarer N he von starken W rmequellen montieren Das Ger t darf nicht in Bereichen mit starken Temperaturwechseln betrieben werden Die Einbaulage des
29. es travaux sur l appareil de commutation il faut qu il soit hors tension et il faut v rifier la mise hors tension et le fait qu il ne peut pas se remettre en marche Si les connexions potentiellement libres des contacts de commutation de s curit sont aliment es par une source externe avec une tension dangereuse il faut s assurer que celles ci sont galement d con nect es lors de travaux l appareil de commutation L appareil de commutation comprend des pi ces entretenir par l utilisateur Si l on apporte des modifications voire des r parations l appareil de commutation la garantie et la responsabilit du fabricant disparaissent Les sorties auxiliaires ne peuvent ex cuter aucune fonction s curis e Vous n avez pas la s curit int gr e et n tes pas test Pour l interpr tation dans les normes du syst me de s curit le site doit tre v rifi par des experts aux moments pr conis s pour s assurer de son bon fonctionnement La v rification doit toujours tre bien document e En cas de non respect ou d abus intentionnel le fabricant n est plus responsable 26 ELMON classic 41 312 ELMON classic 41 812 Relais de s curit 3 G n ralit s et description de fonction L appareil de commutation ELMON classic 41 312 sert au traitement du g n rateur de signal comme les tapis de s curit les profils de contact de s curit et les bumpers de s curit pour assurer les points d crasement et d
30. h und Scherstellen An das Schaltger t kann ein ASO Signalgeber angeschlossen werden Die Ruhestrom berwachung des Signalgebers wird durch einen integrierten Abschlusswiderstand im Signalgeber erm glicht Flie t der Soll Ruhestrom so sind die Sicherheitsrelais angesteuert und die Schaltkontakte geschlossen Wird der Signalgeber bet tigt oder der Signalgeberstromkreis unterbrochen ffnen die Relais Schaltkon takte Ein Meldeausgang mit potentialfreien Schaltkontakten ist verf gbar Eine Bet tigung des Signalgebers bewirkt eine Reaktion des Meldeausganges entsprechen der DIP Schalter Konfiguration Der Meldeausgang darf keine sicherheitsgerichtete Funktionen ausf hren Er ist nicht einfehlersicher und wird auch nicht durch Testung berpr ft Das Schaltger t ist nach EN ISO 13849 1 Sicherheitsbezogene Teile von Steuerungen f r Kat 3 Performance Level e ausgelegt und baumustergepr ft F r die Einhaltung der Kategorie 3 ist der Sicherheitsausgang redundant mit zwei unabh ngigen Schaltelementen aufgebaut Zus tzlich ist das Ger t nach EN 62061 Funktionale Sicherheit sicherheitsbezogener elektrischer elektro nischer und programmierbarer elektronischer Steuerungssysteme baumustergepr ft und kann eine Sicher heitsfunktion bis SIL 3 erf llen Der berwachungszustand des Signalgebers und die angelegte Betriebsspannung werden durch LED ange zeigt Wenn eine Fehlermeldung vorliegt sind alle Sicherheitsausgange inaktiv
31. hazards at crush and shear locations corresponds to the relevant basic safety and health requirements of the following EC Directives as a result of its conception and construction as well as the design we put on the market EC machinery directive 2006 42 EG EN ISO 13849 1 2008 EN ISO 13849 2 2013 EN 62061 2013 09 EN 60947 5 1 2010 04 EN 61000 6 2 2005 EN 61000 6 3 2007 EC type approval Notified Body 0044 T V NORD CERT GmbH Langemarckstra e 20 D 45141 Essen Germany EC Design certification No 44 205 13176203 This declaration of conformity does not absolve the machine designer manufacturer of his obligation to guarantee the conformity of the overall machine to which this product is attached in accordance with the EC Directive Manufacturer and authorized representative for documents ASO Antriebs und Steuerungstechnik GmbH Hansastra e 52 D 59557 Lippstadt 24 ELMON classic 41 312 ELMON classic 41 812 Relais de s curit 1 Table des mati res 1 Table des mati res 25 2 Normes de s curit g n rales et mesures de protection 26 3 G n ralit s et description de fonction 27 A Utlisation conforme iuo o moon UR d aed 28 5 Exemple d application 28 6 Aper u de l appareil 29 Gide Mod les s sis ne tire ent a d un EE aec Kn A 29 6 2 SPA RN Ie cede i re Sue 29 6 3 Bornes de connexion ies
32. ire avec une tension de r seau de 230 V CA AN 50 60 Hz ou avec une basse tension de 24V CA CC En cas d alimentation avec du 24 V CA CC la tension doit r pondre aux exigences de basse tension pour protection SELV La tension d alimentation pour l appareil commutateur doit tre prot g e avec un fusible qui convient Ne jamais utiliser les deux tensions en m me temps La tension d alimentation de 230 V 115 V doit tre raccord e aux bornes L1 N Pour l utilisation avec 24 V il faut raccorder la tension d alimentation aux bornes 24V CA CC En cas d installation fixe il doit y avoir un dispositif s par par exemple un interrupteur d alimentation principal pour le syst me Une prise est un dispositif de s paration suffisant quand elle est facilement accessible 9 2 Connexion du metteur de signal Le metteur de signal doit tre connect avec une boite de r sistance terminale de 8 2 kO aux bornes IN 9 3 Connexion de plusieurs metteurs de signal par circuit de metteur de signal A Les metteurs de signal ASO ne peuvent pas tre connect s en parall le On peut connecter l entr e du metteur de signal un ou plusieurs metteurs de signal Pour ce faire les metteurs de signal sont connect s selon l image 1 en s rie 31 Barre palpeuse SENTIR edge Il est possible de monter au plus 5 SENTIR edge en s rie La longueur totale des SENTIR edge ne doit pas d passer 100 m La longueur max d un SENTIR edge
33. is correctly wired and applied only the green Power LED may be lit up If the red LED illuminates there is a fault in the system which can be delimited by means of the LED e Fault Fault removal Check connections and supply voltage 230 V AC or 115 V at terminals L1 N or 24 V AC DC at terminals 24 V AC DC Tolerance range 10 green LED Supply voltage is missing Power too low or does not light up incorrectly connected green LED Power Internal fault is indicated flashes cyclically by the number of pulses pulse output See signal displays red LED The corresponding sensor Check the connections of the corresponding sensors Fault is recognized squeezed or brittle supply lines etc lights up as being operated Check signal sensor red LED Sensor circuit interrupted Check the connections of the corresponding sensors Fault sensor not connected squeezed or brittle supply lines etc fast flashing defectively connected or defective Check sensor red LED Fault Fault self retaining Carry out manual reset slow flashing Ifthe fault is not found in the wiring the function of the electronic system can be checked by applying a resistance of 8 2 kQ to the sensor input on the switching device Subsequently if the electronics work perfectly the sensor must be checked by means of an ohmmeter For this purpose the connection of the sensor to the switching device must be separated and connected b
34. kt Signalisierung Anzeige etc und darf nicht in den Sicherheitsstromkreis eingebunden werden 10 ELMON classic 41 312 ELMON classic 41 812 Sicherheitsschaltgerat 10 Inbetriebnahme und Funktionspr fung Nach entsprechendem Anschluss aller elektrischen Verbindungen und Einschalten der Versorgungsspannung muss die Anlage Maschine auf korrekte Funktion gepr ft werden Nach erfolgreicher Inbetriebnahme sind die Sicherheitsausg nge STOP 1 und STOP 2 angesteuert Relais kontakte geschlossen Eine Bet tigung des Signalgebers bewirkt ein ffnen der Relaiskontakte Das Melderelais Anschluss AUX schaltet entsprechend der vorliegenden DIP Schalter Stellung Dies wird mit Hilfe der gelben LED AUX angezeigt Das Sicherheitssystem muss in geeigneten Zeitabst nden von Sachkundigen gepr ft werden Die Pr fung muss in jederzeit nachvollziehbarer Weise dokumentiert werden Die Anforderungen des Anlagen Maschi nenherstellers sind zu ber cksichtigen und einzuhalten 11 Fehlerdiagnose Bei korrekter Verdrahtung und Anlegen der Versorgungsspannung darf nur die gr ne LED Power leuchten Bei Aufleuchten der roten LED ist ein Fehler im System vorhanden der sich mit Hilfe der LED eingrenzen l sst o ome id dida Anschl sse und Versorgungsspannung berpr fen 230 V AC oder 115 V an Klemmen L1 N oder 24 V AC DC an Klemme 24 V AC DC Toleranzbereich 10 gr ne LED Versorgungsspannung fehlt Power zu gering leuchte
35. l de sortie symbolique 30 ELMON classic 41 312 ELMON classic 41 812 Relais de s curit 8 Fixation m canique Etui polycarbonate avec raccords vis pour montage en saillie en environnement rude e l appareil commutateur doit tre attach de mani re appropri e sur un lieu de montage qui A convient Apr s avoir enlev le couvercle l tui peut tre fix avec 4 vis Ne pas monter proximit directe d une source de chaleur l appareil ne peut pas tre utilis dans des zones subissant de grandes modifications de temp rature La situation pour le placement de l appareil est libre mais il devrait tre mont l abri d humidit infiltrante pour que le c blage puisse aller vers le bas 9 Connexion lectrique Laconnexion de mauvaises bornes peut d truire l appareil de commutation l faut assurer les conduits flexibles contre les d placements Les c bles de connexion au r seau doivent tre isol s par des tuyaux d isolation Les conduits qui sont l air libre ou l ext rieur des armoires lectriques doivent tre prot g s en cons quence Pour la zone ext rieure non prot g e on ne peut utiliser qu un cable autoris par exemple conduit en caoutchouc Les valeurs limites donn es dans les feuillets techniques pour la tension d alimentation et le pouvoir de coupure du relais doivent tre respect es 9 1 Tension d alimentation La tension d alimentation peut au choix se fa
36. lt self retaining manual reset factory setting S2 Reset ON AUX Mode signal output RLU OFF AUX Mode signal output RL factory setting 7 Operating modes 7 1 Safety output Separate or combined use of the control circuits redundant continuation of the switching contacts In order to make joint use of the switching contacts of both relays a bridge must be set between the STOP1 and STOP2 connections 7 2 Automatic reset 1 ON After removing a fault in a sensor circuit or after a voltage failure the switching unit will automatically release output again 7 3 Fault self retaining manual reset S1 OFF After removingl a fault in a sensor circuit or after a voltage failure the switching unit will only release the output s again if the RESET contacts 500 ms after the elimination of the disruption are closed by means of a pushbutton This completely prevents any automatic re start A permanent bridging of the RESET contacts does not cause an automatic reset 7 4 Signaling output without any delay RLU mu S2 ON Output In this mode of operation the corresponding AUX signaling output is activated without delay if any fault is signaled on the corresponding channel The output is always inactive in the de energized state of the switching device Safety output symbolic Signaling output symbolic Aux Relay 7 5 Signaling output delayed RL Output S2
37. ltage The supply voltage can optionally be effected by means of a mains voltage of 230 V AC 50 60 Hz ELMON rail 41 822 115 V AC 50 60 Hz or a low voltage of 24 V AC DC For a supply with 24 V AC DC the voltage must correspond to the requirements for protective low voltages SELV The supply line to the switching device must be protected by means of a suitable fuse Never apply both voltages simultaneously The 230 V supply voltage must be applied to the L1 N terminals For operation with 24 V the supply voltage must be connected to the 24 V AC DC terminals For a fixed installation a separating device must be available for example a main switch for the system A mains plug is sufficient as a separating device if it is freely accessible 9 2 Connection of sensor The sensor with a terminating resistor of 8 2 kO must be connected to the IN terminals 9 3 Connection of several sensors per sensor circuit AN ASO sensors must not be connected in parallel One or several sensors can be connected to the signal transmitter input For this purpose the individual sensors are connected in series in accordance with Figure 1 20 ELMON classic 41 312 ELMON classic 41 812 Safety Relais Safety contact edge SENTIR edge A maximum of 5 SENTIR edge devices can be connected in series The maximum total length of the SENTIR edge must not exceed 100 m The length of a SENTIR edge can be up to 25 m The total line length of the series con
38. n BxHxT Geh use 120 x 80 x 56 mm Geh use incl Verschraubungen 120 x 102 x 56 mm Schutzart mit M16 Verschraubungen IP65 mit M16 Verschlu stopfen IP54 Schutzklasse Verschmutzungsgrad 2 berspannungskategorie Hl Bemessungsisolationsspannung 250V Bemessungssto spannungsfestigkeit 4 00 kV Gewicht 350g 20 C bis 55 C ein oder feindrahtige Leitung 0 75 1 5 mm Temperaturbereich Querschnitt Anschlussleitungen Zulassungen ELMON classic 41 312 41 812 EN ISO 13849 1 2008 Kategorie 3 PLe MTTFd 236 Jahre DC 99 EN 62061 2013 SILCL 3 PFHd 8 59E 09 1 h Elektronik MTTFd 625 Jahre DC 99 B10d 2000000 SiS seres rds MTTFd 380 Jahre DC 9996 Nop 52560 Pr fbericht Nr 3512 6372 Zertifikat Nr 44 780 13 xxxxxx EG Baumuster pr fbescheinigung Nr 44 205 13176203 12 ia d TUV NORD T V NORD CERT GmbH ELMON classic 41 312 ELMON classic 41 812 Sicherheitsschaltgerat 14 EG Konformit tserkl rung Hiermit erkl ren wir dass die nachfolgend bezeichneten Produkte der Baureihe ELMON rail 41 312 Artikelnummer 1114 0060 Format Seriennummer yymmnnnnn ELMON rail 41 812 Artikelnummer 1114 0130 Format Seriennummer yymmnnnnn Sicherheitsschaltger t zur Kombination mit Schaltleisten Schaltmatten und Schalt puffern zur Vermeidung von Gefahren an Quetsch und Scherstellen aufgrund ihrer Konzipierung und Bauart sowie in der von uns in Verkehr g
39. nd Funktionsbeschreibung 5 4 Bestimmungsgem e Verwendung 6 5 Anwendungsbeispiele 6 6 Ger te bersicht 7 6 1 Ausf hrungen 7 6 2 Signalanz igen 422245 ee de ee vow ox e ro qo 7 6 3 Anschlussklemm n u 2 snm a aie tn ROS a aR ea 7 6 4 DIP Schalter zum Einstellen derBetriebsart 8 7 Betriebsarten 5 545 44 ste 02a cee ECRIRE QU RUE Sek ee 8 7 1 Sicherheitsausgang 8 7 2 Automatischer Reset 8 7 3 Fehlerselbsthaltung manueller Reset 8 7 4 Meldeausgang unverz gert RLU 8 7 5 Meldeausgang verz gert RL 8 8 Mechanische Befestigung 9 9 Elektrischer Anschluss 9 9 1 Versorgungsspannung 9 9 2 Anschluss des Signalgebers 9 9 3 Anschluss von mehreren Signalgebern pro Signalgeberkreis 9 9 4 Anschluss Steuerstromkreise 10 9 5 Anschluss Reset ee 10 9 6 Anschluss Meldekontakt 10 10 Inbetriebnahme und Funktionspr fung 11 11 Fehlerdiaghose ox ka Rm m san and 11 12 Au erbetriebnahme und Entsorgung 11 13 Technische Daten ae 235 43 5
40. nected SENTIR edge must not exceed 25 m Safety contact bumper SENTIR bumper A maximum of 5 SENTIR bumper devices can be connected in series The maximum total length of the SENTIR bumpers must not exceed 15 m The length of a SENTIR bumper may be up to 3 m The total line length of the series connected SENTIR bumpers must not exceed 25 m Safety contact mat SENTIR mat A maximum of 10 SENTIR mats can be connected in series The maximum total surface area must not exceed 10 m2 The size of a SENTIR mat can be up to 1350 x 2350 mm The total line length of the series connected SENTIR mat must not exceed 25 m Before connecting the series connected sensors it is recommended to measure the resistance value of the wiring In the case of non operated sensors the resistance must be 8 2 kO 500 Q If the sensor is operated the resistance must not exceed 500 Q Sensor 1 Sensor 2 Sensor n gll 2 I 2 ee 2 Fig 1 Interconnecting several sensors here using the example of the safety contact edge 9 4 Connection of control circuits The control circuits to be monitored are to be connected to the STOP 1 and STOP 2 terminals If a redundant continuation of the switching contacts is not desired a bridge can be inserted between STOP1 and STOP2 may be connected The use of different voltage potentials does not correspond to any intended In the event of any redundant u
41. onformes L utilisation de facon particuli re n cessite un accord du fabricant 5 Exemple d application Une surveillance de la s curit du profil de s curit avec d clenchement de d marrage via un bouton de d marrage et poursuite s par e du circuit de commande cat gorie 3 utilisation conforme selon la norme EN ISO 13849 1 Pour le t moin de fonctionnement des protections de charge K1 et K2 les contacts ouverts de ces protections sont engag s dans le circuit de d part RESET La sortie du relais de signalisation sert visualiser l tat de commutation du profil de s curit Le sch ma de connexion est hors tension Capteur pas actionn 1 G n rateur de signal profil tapis ou bumper 2 Bouton de d marrage 28 ELMON classic 41 312 ELMON classic 41 812 Relais de s curit 6 Aper u de l appareil 6 1 Mod les Etui en polycarbonate avec raccords vis pour montage en saillie dans un environnement non cl ment Mod le Tension d alimentation ELMON classic 41 312 230 V 50 60 Hz et 24 V CA CC ELMON classic 41 812 115 V 50 60 Hz et 24 V CA CC 6 2 Signaux LED Power vert Etat de marche allum Message d erreur donn e impulsion ASD ey Solutions LED Fault rouge metteur de signal actionn allum Courant metteur de signal interrompu clignote rapidement Mode d erreur maintenu clignote lentement ELMON classic 4 PN 1114 0060 B
42. rhalb des g ltigen Wertbereiches Fehler bei Testung Signaleingang Ausgangssteuerung Relais gest rt Daten bertragung zwischen Mikrocontroller gest rt 6 3 Anschlussklemmen ELMON classic 41 312 Versorgungsspannung 230 V 50 60 Hz ELMON classic 41 812 Versorgungsspannung 115 V 50 60 Hz Anschluss Signalgeber Schaltkontakt Sicherheits Relais 1 Schaltkontakt Sicherheits Relais 2 Schaltkontakt Melderelais Anschluss manuelle R cksetzung Wiederanlauf Taster NO optional 6 4 DIP Schalter zum Einstellen der Betriebsart S1 AUX ON Automatischer Reset OFF Fehlerselbsthaltung manueller Reset Werkseinstellung S2 Reset ON Modus Meldeausgang AUX RLU OFF Modus Meldeausgang AUX RL Werkseinstellung 7 Betriebsarten 7 1 Sicherheitsausgang Getrennte oder kombinierte Nutzung der Steuerstromkreise redundante Weiterf hrung der Schaltkontakte Um die Schaltkontakte beider Relais gemeinsam zu benutzen muss eine Br cke zwischen den Anschl ssen STOP1 und STOP2 gesetzt werden 7 2 Automatischer Reset 1 ON Nach Beseitigung einer St rung eines Signalgeberstromkreises oder nach Spannungsausfall gibt das Schalt ger t den Ausgang automatisch wieder frei 7 3 Fehlerselbsthaltung manueller Reset S1 OFF Nach Beseitigung einer St rung im Signalgeberstromkreis oder nach Spannungsausfall gibt das Schaltger t den oder die Ausg nge erst wi
43. s sans accord pr alable 25 2 Normes de s curit g n rales et mesures de protection Le fabricant et l utilisateur du site de la machine o l on utilise le dispositif de s curit sont responsables de d terminer et respecter toutes les normes et r gles de s curit selon leur propre responsabilit Le dispositif de protection garantit en connexion avec la commande ci dessus une s curit fonctionnelle mais pas la s curit de l ensemble du site de la machine Avant d utiliser l appareil il est n cessaire d valuer la s curit de l ensemble du site de la machine selon la directive de la machine 2006 42 EG ou selon la norme de produit correspondante Le mode d emploi doit toujours se trouver sur les lieux d utilisation du dispositif de protection Il doit tre lu fond et utilis par chaque personne qui est concern e par l utilisation l entretien ou la main tenance du dispositif de protection L installation et la mise en service du dispositif de protection ne peuvent tre effectu es que par la ressource d di e connaissant bien ce mode d emploi et les prescriptions en vigueur sur la s curit au travail et la pr vention des accidents Les indications dans ce guide doivent absolument tre suivies et respect es Les travaux lectriques ne peuvent tre effectu s que par des lectriciens Les r gles de s curit du g nie lectrique et du syndicat professionnel doivent tre respect es Pour effectuer d
44. schlie lich f r den gewerblichen Gebrauch B2B vorgesehen Nach Nutzungsbeendigung sind die Produkte gem f allen rtlichen regionalen und nationalen Vorschriften zu entsorgen ASO nimmt die Produkte auch gern zur ck und entsorgt diese ordnungsgem 11 13 Technische Daten Versorgungsspannung ELMON classic 41 312 230 V AC 50 60 Hz Nominalwert Netzspannung Anschlusswiderstand Signalgeber 82kQ RNom ELMON classic 41 812 115 V AC 50 60 Hz Typ X 24 V AC DC 10 2 2 VA 230 V AC oder 115 V 1 5 W 24 V DC 1 2 VA 24 V AC oberer Schaltwert Netzanschlussart unterer Schaltwert Kleinspannung UE Leistungsaufnahme PNetz_max PE_max PE_max Sicherheitsrelais Melderelais Nennstrom DC 3 30 V DC Max Schaltstrom Rao gt 12 0kQ 2 30 V DC 1A 230 V AC Nennstrom AC 1 A 230 V AC Mechanische Lebensdauer gt 105 Bet tigungen Mechanische Lebensdauer gt 10 Bet tigungen Betriebsart RL Einschaltverz gerung Ausschaltverz gerung dis 0 5 Sek Reaktionszeit Betriebsart RL Einschaltdauer 500 ms Power on 700ms AC 15 230V AC 1A 550000 Op DC 13 30V DC 3A 120000 Op Einschaltverz gerung Gebrauchskategorie der Bet tigung des Signalgebers Geh use ABS transparenter Deckel Polycarbonat 3 Sek Bei der RLU Version schaltet das Melderelais synchron zu 120 Abmessunge
45. se of the switching contacts only voltages with the same potential use within specifications Depending on the nominal current the control circuits are to be protected by a corresponding fuse or the nominal current on the control circuits must be limited to the maximum value by means of other measures 9 5 Connection Reset For the operating mode manual reset the necessary reset switch must be connected to the RESET terminals 9 6 Connection of signaling contact The signaling AUX contact only serves as an auxiliary contact signaling display etc and must not be inte grated into the safety circuit 21 10 Commissioning and function testing After a corresponding connection of all electrical connections and switching on the supply voltage the system machine must be checked for correct functionality After successful commissioning the safety STOP1 and STOP2 outputs are driven relay contacts closed An operation of the signal transmitter causes an opening of the relay contacts The signaling relay AUX connection switches in accordance with the present DIP switch position This is indicated by means of the yellow AUX LED The safety system must be inspected by competent specialists at suitable intervals The check must be documented in a way that allows it to be traced at any time The requirements of the system machine manufacturer are to be taken into account and observed 11 Fault diagnosis If the supply voltage
46. t nicht oder falsch angeschlossen Gr ne LED Interner Fehler wird durch e r Power Siehe Signalanzeigen blinkt zyklisch Pulsausgabe Anzahl Pulse angezeigt Rote LED Anschl sse der entsprechenden Signalgeber berpr fen Der entsprechende Signalgeber S GE s Fault T RU abgequetschte Zuleitungen br chige Zuleitungen etc wird als betatigt erkannt 3 S leuchtet Signalgeber berpr fen Rote LED Signalgeberkreis unterbrochen Signalgeber nicht angeschlossen Fault blinkt schnell fehlerhaft angeschlossen oder defekt Anschl sse der entsprechenden Signalgeber berpr fen abgequetschte Zuleitungen br chige Zuleitungen etc Signalgeber berpr fen Rote LED Fault Fehlerselbsthaltung Manuellen Reset ausf hren blinkt langsam Liegt der Fehler nicht in der Verdrahtung kann die Funktion der Elektronik durch Belegen des entspre chenden Kontaktleisten Eingangs am Schaltger t mit einem 8 2 kO Widerstand berpr ft werden Arbeitet danach die Elektronik einwandfrei muss der Signalgeber mit einem Widerstandsmessgerat berpr ft werden Hierf r muss die Verbindung des Signalgebers zum Schaltger t aufgetrennt und mit einem Widerstandsmessger t verbunden werden Bei unbet tigtem Signalgeber muss der Widerstand 8 2 kO 500 O betragen Ist der Signalgeber bet tigt darf der Widerstand 500 O nicht berschreiten 12 Au erbetriebnahme und Entsorgung Die von ASO hergestellten Produkte sind aus
47. tion des deux relais il faut tablir un pont entre les connexions STOP1 et STOP2 7 2 R initialisation automatique S1 ON Apr s avoir r solu une panne d un circuit de metteur de signal ou apr s une panne de courant l appareil de commutation lib re automatiquement la sortie 7 3 Enclenchement d erreur r initialisation manuelle S1 OFF Apres avoir r solu une panne d un circuit de metteur de signal ou apr s une panne de courant l appareil de commutation lib re les sorties seulement apr s que les contacts RESET 500 ms apr s l limination de la perturbation soient ferm s par un bouton Un red marrage automatique est donc exclu Un pontage durable des contacts RESET ne provoque pas un reboot automatique 7 4 Sortie de signal action instantan e RLU Eu S2 ON Output Dans ce mode de fonctionnement la sortie de signal AUX est activee instantanement quand une erreur quelconque sur le canal correspondant est signal e La sortie est toujours inactive quand l appareil commuta teur est d connect du courant Sortie de s curit symbolique Signal de sortie symbolique Aux Relay 7 5 Signal de sortie ralenti RL Output S2 OFF Dans ce mode de fonctionnement le signal de sortie AUX est ralenti de 0 5 seconde et reste donc pendant Aux Relay max 3 secondes actif quand une erreur est signal e Sortie de s curit symbolique Signa
48. tput zu ecu REA e a ORA ELE A 19 7 2 Automaticreset ms unes ae ordeum e RP RUE ae Ee 19 7 3 Faultself retaining manual reset 19 7 4 Signaling output without any delay RLU 19 7 5 Signaling output delayed RL 19 8 Mechanical mounting 20 9 Electrical connection 20 9 1 Supply voltage 20 9 2 Connection Of sensor 2 42 8 2 au de donne Ra beatae da dt 20 9 3 Connection of multiple sensors per sensor circuit 20 9 4 Connection of control circuits 21 9 5 Connection Reset ee ENEE Rr m ee a BERE nn 21 9 6 Connection of signaling contact 21 10 Commissioning and function testing 22 11 Fault diagnosis ss momo komo m ae wae EE 22 12 Decommissioning and disposal 22 13 Technical data 4 244 EE E 248 4 Xn OXON 23 14 EC Declaration of Conformity 24 All rights reserved to implement technical and operationally relevant changes of the products and devices shown in this documentation at any time without prior notice 14 ELMON classic 41 312 ELMON classic 41 812 Safety Relais 2 General safety regulations and protection measures e The manufacturer and user of the system machine on which the protection system is used are responsible for coordinating an
49. uand une poursuite redondante des contacts de connexion n est pas souhait e on peut tablir un pont entre STOP 1 et STOP 2 En cas d utilisation redondante des contacts de connexion on peut seulement connecter des tensions potentiel identique L utilisation de divers potentiels de tension n est pas conforme aux regles d utilisation Les circuits de c blage lectrique doivent tre prot g s du courant de base avec le fusible correspondant ou le courant de base sur les circuits de c blage lectrique doit tre limit par d autres mesures la valeur maximale 9 5 Connexion r initialisation Pour le mode de fonctionnement r initialisation manuelle il faut connecter le connecteur de r initiali sation aux bornes RESET 9 6 Connexion contact de signalisation Le contact de signalisation AUX ne sert que comme contact d aide signalisation affichage etc et il ne peut tre int gr dans le circuit lectrique de s curit 32 ELMON classic 41 312 ELMON classic 41 812 Relais de s curit 10 Mise en service et essai de fonction Apr s la connexion correspondante de toutes les connexions lectriques et l allumage de la tension d alimentation il faut v rifier que le site la machine fonctionne correctement Apr s la mise en service r ussie il faut allumer les sorties de s curit STOP1 et STOP2 contacts relais ferm s En actionnant le metteur de signal on ouvre les contacts relais Le relais d
50. y means of an ohmmeter In the case of a non operated sensor the resistance must be 8 2 kO 500 Q If the sensor is operated the resistance must not exceed 500 Q 12 Decommissioning and disposal The products manufactured by ASO are exclusively intended for commercial use B2B At the end of use the products must be disposed of according to all local regional and national regulations ASO is also happy to take back the products and disposes of them properly 22 ELMON classic 41 312 ELMON classic 41 812 Safety Relais 13 Technical data Supply voltage Mains voltage Terminating resistor sensor ELMON classic 41 312 230 V AC 50 60 Hz Nominal value ELMON classic 41 812 115 V AC 50 60 Hz Supply type Low voltage UE Upper switching Typ X point 24 V AC DC 10 Lower switching Power consumption PNetz_max 2 2 VA 230 V AC oder 115 V point PE_max 1 5 W 24 V DC Safety relay Nominal current DC PE_max 1 2 VA 24 V AC Auxiliary relay 3A 30 V DC max switching current Nominal current AC 2 A 30 V DC 1 A 230 V AC 1A 230 V AC Mechanical life time Mechanical life time gt 105 actuations gt 10 actuations Switch off delay reaction time Operating mode RL 12ms Switch on delay 0 5 Sek Switch on delay Operating mode RL Switch on duration 500 ms Power on 700ms Utilization category