Home

Istruzioni d`uso del prodotto

image

Contents

1. dispositif doit tre utilis par personnel m dical sp cialis I prodotti FERTIRAM sono fabbricati con materiali biocompatibili idonei alla fecondazione assistita sottoposti a test MEA embriotossicit e LAL controllo endotossine batteriche e sterilizzati a raggi beta FERTIRAM products are manufactured from biocompatible materials suitable for human assisted fertilization MEA amp LAL tested and beta Sterilized BIMONOCYTE BIMONOCYTE N Stefania Del Rio Ultima revisione Aggiornata al Gennaio 2013 Quality Assurance Manager
2. 0476 RI MOS s r l viale Gramsci 29 41037 MIRANDOLA MO ITALY tel 39 0535 25755 fax 39 0535 25509 e mail info rimos com www rimos com FERTIRAM PRODOTTI MONOUSO STERILI PER LA FECONDAZIONE ASSISTITA Disposable sterile devices for assisted fertilization BIMONOCYTE BIMONOCYTE N Ago prelievo ovociti e lavaggio follicolare Needle for ovum pick up and follicle flushing COD 770302 770302 T 770302 TL COD 770304 770304 T 770304 TL G Istruzioni d uso Preparare la zona vaginale della paziente e l eventuale campo sterile Proteggere la sonda ecografica con un coprisonda sterile e collegarla ad una guida assicurandosi che sia ben agganciata ad essa Inserire la sonda in vagina per verificare la persistenza dei follicoli e la loro accessibilit Sempre sotto controllo ecografico inserire BIMONOCYTE o BIMONOCYTE N nella guida collegata alla sonda ecografica Spingere l ago con decisione attraverso la parete vaginale fino ad introdurlo nello stroma ovario e nel follicolo Aspirare delicatamente uno ad uno tutti i follicoli tramite pompa ad aspirazione costante Effettuare un lavaggio della cavit follicolare attraverso la seconda via del sistema provvista di valvola unidirezionale Rimuovere la sonda alla fine della procedura L utilizzo di BIMONOCYTE piuttosto che BIMONOCYTE N e viceversa dipende dal tipo di connessione dell ago alla pompa di aspirazione pi idoneo In BIMONOCYTE la connessione avviene direttame
3. ger la sonde chographique avec une protection st rile et la connecter une aiguille guide S assurer que l aiguille guide soit bien reli e la sonde Introduire la sonde dans le vagin pour v rifier la persistance et l accessibilit folliculaire Sous guidage chographique introduire BIMONOCYTE ou BIMONOCYTE N dans l aiguille guide connect e la sonde Pousser l aiguille travers le paroi vaginal avec d cision jusqu ponctionner le stroma ovarien et le follicule Aspirer les follicules d licatement un apr s l autre avec un pompe d aspiration Effectuer un lavage folliculaire travers la seconde voie du syst me pourvue d une valve unidirectionnelle A la fin de la proc dure enlever la sonde et l aiguille L emploi de BIMONOCYTE plut t que BIMONOCYTE N et vice versa d pend du type de jonction de l aiguille la pompe d aspiration consid r le plus appropri BIMONOCYTE se relie la pompe d aspiration par un raccord m le 7 fig b BIMONOCYTE N se relie la pompe d aspiration par tubulure de liaison de 80 100 cm et un raccord luer lock femelle 8 avec raccord adaptateur 9 qui permet diff rentes possibilit s de connexion fig c Avertissements Lire le mode d emploi avant l utilisation Ne pas r utiliser Utiliser seulement si l emballage est en parfait tat Utiliser imm diatement apr s louverture du sachet Apr s l utilisation d truire le dispositif selon les r gles en vigueur Le
4. nd the sterile field Use a vaginal probe cover to protect the ultrasound probe and connect it to a needle guide Make sure that connection is well secured Introduce the ultrasound probe in the vagina to confirm follicle persistence and accessibility Under ultrasound control introduce BIMONOCYTE or BIMONOCYTE N in the guide needle connected to the ultrasound probe Push the needle through the vaginal wall firmly until the ovarian stroma and the follicle are reached Gently aspirate one follicle after the other by controlled vacuum pump Perform follicle flushing through the second way of the system that is provided with a one way valve At the end of the procedure remove the ultrasound probe and the needle Use of BIMONOCYTE rather than BIMONOCYTE N and vice versa depends on the more suitable needle connection to the aspiration pump Within BIMONOCYTE a male connector is directly connected to the pump tubing 7 picture b Within BIMONOCYTE N the needle is connected to the pump by a 80 100 cm extension tubing and a female luer lock connector 8 with additional adapter 9 allowing multiple connections picture c Caution Read the instructions before using the device Do not reuse Use only if the package is not damaged Use immediately after opening Dispose of after use according to the laws in force For use only under trained medical staff Mode d emploi Pr parer la zone vaginale de la patiente et ventuellement le champ st rile Prot
5. nte al tubo della pompa tramite raccordo maschio 7 figura b In BIMONOCYTE N la connessione avviene tramite prolunga di 80 100 cm con raccordo luer lock femmina 8 e adattatore 9 che consente una varia tipologia di connessioni figura c Avvertenza Leggere le istruzioni prima dell uso Non riutilizzare Utilizzare solo se la confezione integra Utilizzare immediatamente dopo l apertura della busta Distruggere dopo l utilizzo in accordo alle norme vigenti Il dispositivo deve essere utilizzato solo da personale medico specializzato E ER O ina i TUBO LAVAGGIO _ RUBINETTO Washing Tube Stopcock M RACCORDO UNIVERSALE Universal Connector RACCORDO UNIVERSALE Universal Connector TUBO DI ASPIRAZIONE sz 7 Suction Tube SIT 27 __ INTERRUTTORE DI FLUSSO RACCORDO Y AGO CANNULA Flow Interrupter connector Needle LUER LOCK ATTACCO POMPA Pump Connection Luer lock TAPPO Ca TUBO PROLUNGA Extension Tube LA RACCORDO UNIVERSALE Universal Connector BIMONOCYTE BIMONOCYTE N Stefania Del Rio Ultima revisione Aggiornata al Gennaio 2013 Quality Assurance Manager 0476 RI MOS s r l viale Gramsci 29 41037 MIRANDOLA MO ITALY tel 39 0535 25755 fax 39 0535 25509 e mail info rimos com www rimos com Instructions for use Prepare the vaginal area of the patient a

Download Pdf Manuals

image

Related Search

Related Contents

Network Video Recorder User Manual  MS-12-37 - Swagelok  Fluids (Anti-freeze & Brake fluid) and Cleaners  Ecran (0,4Mo) - L`Ecole de Yoga et de Méditation  OPERATING INSTRUCTIONS Vacuum tissue processor MTM II  Télécharger le texte de l`ATE  Sensor Inalámbrico WiWeather E  

Copyright © All rights reserved.
Failed to retrieve file