1. at 2 second intervals It implies that it has not been assigned a node ID and cannot work with Z Wave enabled devices Please get familiar with the terms below before starting the operations Description Add a Z Wave enabled device to the existed Z Wave network Delete a Z Wave enabled device from the connected network Association After inclusion you have to define the relationship between devices Through association device can be assigned as master or slave and specify which slave is going to be controlled by which master Restore the device to factory default Auto Inclusion The function of auto inclusion will be executed as long as the Module does not have node ID when the first power is applied After node ID has been linked auto inclusion will run automatically after the execution of exclusion reset is successful Note Auto inclusion lasts for 4 minute or until the execution of inclusion is completed during which the node information of explorer frame will be emitted once every 5 seconds Unlike inclusion function as shown in the table below the execution of auto inclusion is free from pressing the link button on the Module The table below lists an operation summary of basic Z Wave functions Please refer to the instructions for your Z Wave Certificated Primary Controller to access the setup function and to include exclude associate devices Function Description LED Indication No node ID
2. After power is applied if the module 2 second on 2 second off does not record a node ID provided by controller 1 Have Z Wave remote module entered inclusion mode button one time LED 2 Pressing link button three times blinks for 0 5 sec and within 1 5 seconds will enter then off inclusion mode 1 Have Z Wave remote module entered exclusion mode 2 Pressing link button three times Inclusion When press on the link Exclusion When press on the link button one time LED blinks for 0 5 sec and within 1 5 seconds will enter then off exclusion mode Node ID has been excluded 2 second on 2 second off successfully Pressing link button three times When press on the link within 1 5 seconds button one time LED blinks for 0 5 sec and Within 1 second press link button then off cleared and reset to factory default Association Have Z Wave remote module entered When press on the link association mode first button one time LED are blinks for 0 5 sec and Pressing link button three times within 1 5 seconds will enter association emon mode LED Indication To distinguish what mode the Module is in view from the LED for identification State Type LED Indication Normal Under normal operation with node ID when manual switch input from open NO to short NC or from short NC to open NO the LED would blink for 0 5 second and then go off No node ID Under normal operation but without allocated node ID th
3. COMMAND_CLASS_BASIC COMMAND_CLASS_CONFIGURATION COMMAND_CLASS_MANUFACTURER_SPECIFIC COMMAND_CLASS_VERSION COMMAND_CLASS_ASSOCIATION_V1 Choosing a Suitable Location 1 Do not locate the Module facing direct sunlight humid or dusty place AC input AC220 240V 50Hz Europe Australia AC100 120V 60Hz US The suitable ambient temperature for the Module is 0 C 40 C Do not locate the Module where exists combustible substances or any source of heat e g fires radiators boiler etc 5 After putting it into use the body of Module will become a little bit hot of which phenomenon is normal SN Installation Note Please note that it is a must to call for a licensed electrician for installation Install this Module into a wall box of which wiring connection is shown hereunder AC power e input i lt _ Link button lt gt ee enna switch input HACO1 can be installed into the in wall power box the power cord have to be connected to the main AC power the manual switch input cable is wired to normal NO open NC close button or switch When the wiring connection is completed please follow the previous instruction to operate the Inclusion and Association process to finish HACO1 s connection and network setting with controlled device ex HANO1 fA fo Troubleshooting Symptom Cause of Failure The Module not working 1 Improper wiring 1 Check power connections and LED off connection 2 D
4. HACO1 eV 7Ae Sonne eee n This in wall remote module is a transceiver which is a Z Wave enabled device and is fully compatible with any Z Wave enabled network Mini size design let the module can easily put into the wall box and still have enough space to install the traditional wall switch There are many application for the module one application is connect the 2 wire of manual switch input to most of the wall switch sell in the market while the connected wall switch been switched ON or OFF the module will send the correspond signal to the associated devices like Z Wave switch module HANO1 or any Z Wave ON OFF or dimmer module Another application is connect this module to any traditional wire sensor which has NC NO manual switch input output and this will easily convert those wire sensors into wireless Z wave sensors With the external antenna let this module have excellent communicate RF range and this will let the module not only send signal to the associated device by itself easily but also act as a good routing node in the z wave mesh network Adding to Z Wave Network In the front casing there is a link button with LED indicator which is used to carry out inclusion exclusion reset or association F spears Ques H LN GS LED indicator ele N ai Link button ee S Q ZA I Front View Side View When first power is applied the LED flashes on and off alternately and repeatedly
5. e LED flashes on and off alternately at 2 second intervals Programming 1 Z Wave s Grouping Feature Association Command Class Ver 1 The remote module supports association with maximum 5 node for Grouping 1 Grouping 1 supports BASIC_ SET When the manual switch input is from NC to NO or from NO to NC HACO1 would send Basic Set Command to the nodes in Grouping 1 to On or Off the controlled device Basic Set Command Manual switch Command Class Basic Basic Set Value OxFF 255 input at NC Manual switch Command Class Basic Basic Set Value 0x00 0 input at NO 2 Z Wave s Configuration 2 1 Basic Set Level The Basic Set Command is sent with value to have the receiving device recognize the value for controlled level for example if the Basic Set Command sent to dimmer with value the dimmer would activate the luminance according to the value 0 Off 1 99 On Binary Switch Device Dim Level Multilevel Switch Device Configuration Command Function Parameter Size Range Default Number BasicSetlevel 1 1 o0 9 9 2 2 Amount Of Delay seconds This is applied to determine the delay time setting to send the Basic Set Off command when the manual switch input at NO open Example 0 immediately Off 1 127 delay 1 127 second to Off Configuration command Function Parameter Size Range Default Number 3 Supported Command Classes In Brief COMMAND_CLASS_SWITCH_BINARY
6. on t open up the Module and 2 The Module break send it for repair down The Module LED illuminating but cannot control the ON OFF Check if the load Set the ON OFF switch of the connected to the Module load connected to ON has its own ON OFF Switch of the load attached switch The Module LED 1 Not carry out illuminating but the association Detector cannot control 2 Same frequency the Module interference 1 Carry out association 2 Wait for a while to re try Specification Power Input AC 100 240 V 50 60Hz AC220 240V 50Hz Europe Australia AC100 120V 60Hz US IRF Operation Range Minimum 30 m indoor line of sight Operating Temperature 0 C 40 C Frequency Range 868 42 MHz Europe 908 42MHz US 921 42MHz Australia Specifications are subject to change and improvement without notice G7 ce X Model number information HAC01 0 US 908 42MHz HACO1 1 Europe 868 42MHz HACO1 2 Australia 921 42MHz Warning Do not dispose of electrical appliances as unsorted municipal waste use separate collection facilities Contact your local government for information regarding the collection systems available If electrical appliances are disposed of in landfills or dumps hazardous substances can leak into the groundwater and get into the food chain damaging your health and well being When replacing old appliances with new once the retailer is legally obligated to take back your old appliance fo
7. r disposal at least for free of charge