1. 33 ASEP 50 ASEP INTRODUCTION This instruction sheet provides you with the information required to safely own and operate your Coleman product Retain these instructions for future reference The Coleman product you have purchased is of the highest quality workmanship and material and has been engineered to give you long and reliable service Coleman products are carefully tested inspected and packaged to ensure safe delivery and operation Please examine your item s carefully to ensure that no damage occurred during shipment If damage has occurred please contact the place of purchase They will assist you in replacement or repair if required READ THESE INSTRUCTIONS CAREFULLY BEFORE ATTEMPTING TO INSTALL OPERATE OR SERVICE YOUR COLEMAN PRODUCT KNOW THE PRODUCT S APPLICATION LIMITATIONS AND POTENTIAL HAZARDS PROTECT YOURSELF AND OTHERS BY OBSERVING ALL SAFETY INFORMATION FAILURE TO COMPLY WITH THESE INSTRUCTIONS COULD RESULT IN PERSONAL INJURY AND OR PROPERTY DAMAGE DESCRIPTION The pump you have purchased is a submersible effluent pump for use in basins or lift stations and suitable for pumping sewage effluent wastewater and other non explosive non corrosive liquids with up to 1 2 spherical solids SAFETY GUIDELINES Make certain pump is disconnected from power source before attempting to service or remove any component Do not use to pump flammable or explosive fluids such as gasoline fuel oi
2. Installer une soupape d arr t sur le tuyau d coulement Instale una v lvula de retenci n en la tuber a de descarga Check valve leaking Fuite la soupape d arr t e Escape en la v lvula de retenci n Inspect check valve for correct operation V rifier la soupape d arr t pour obtenir un bon fonctionnement Verifique que la v lvula de retenci n funcione correctamente Install larger basin Installer une bassin de r ception plus grand Instale un sumidero con un fondo mayor No corrective action is required e Aucune mesure corrective n est requise No se requiere de ninguna acci n correctiva Basin too small for inflow Bassin de r ception trop petit pour l afflux El fondo del sumidero es muy peque o o est inundado This pump comes with a bleed hole that allows trapped air to escape from the pump preventing air lock Water spraying out of this hole is completely normal Cette pompe est livr e avec un orifice de purge qui permet a l air emprisonn de s chapper de la pompe vitant ainsi un bouchon d air De l eau qui gicle par ce trou est tout fait normale Esta bomba viene con un respiradero que per mite que el aire atrapado escape de la bomba evitando las bolsas de aire Es completamente normal que salga agua de este orificio ATTACH ORIGINAL RECEIPT HERE FOR WARRANTY CONSIDERATION Franklin Electric Company Inc warrants that the products specified in this warranty are free
3. Las solicitudes de servicio bajo esta garant a se realizar n contactando a Franklin Electric al tel fono 1 888 271 1370 para obtener una autorizaci n para devoluci n de mercanc a NO DEVUELVA EL PRODUCTO A LA TIENDA DONDE LO ADQUIRIO Franklin Electric proporcionar instrucciones para la devoluci n con el flete prepagado al departamento de garant a de Franklin Electric junto con la factura de la compra Esta garant a estipula la nica obligaci n de Franklin Electric y la soluci n exclusiva que tiene el cliente si el producto tiene defectos RENUNCIA Todo compromiso oral con respecto al producto por parte del vendedor el fabricante los representantes o terceros no constituye garant a alguna no debe ser considerado como tal por el usuario y no forma parte del contrato de venta La nica obligaci n del vendedor y el fabricante y el nico recurso del comprador ser el reemplazo y o reparaci n del producto que har el fabricante del producto tal como se describe aqu Ni el vendedor ni el fabricante ser n responsables por cualquier lesi n p rdida o da o directo incidental o emergente lo que incluye sin limitaci n da os incidentales o emergentes por p rdida de ingresos de ventas lesiones a personas o propiedades o cualquier otro da o incidental o emergente que resultara del uso o incapacidad de uso del producto y el usuario acuerda que no hay ning n otro recurso Antes de usarlo el usuario deber determ
4. pos es de The Coleman Company Inc utilis es sous licence Fabriqu par Franklin Electric Company Inc Oklahoma City OK 73157 2010 2013 The Coleman Company Inc Todos los derechos reservados Coleman y ED son marcas registradas de The Coleman Company Inc usadas bajo licencia Fabricado por Franklin Electric Company Inc Oklahoma City OK 73157 2010 Form 998896 Rev 002 11 2014
5. s dans cette garantie contre tout d faut de materiaux et de main d ouvre Si lors de la dur e d utilisation par son propri taire le mod le 33 ASEP 50 ASEP de Coleman s av rait d fectueux le produit sera r par ou remplac au choix de Franklin Electric Company Inc selon les termes et conditions indiqu s ci dessous CONDITIONS ET TERMES G N RAUX Cette garantie ne couvre pas les dommages caus s par une catastrophe naturelle et par usure normale et elle ne couvre pas non plus les produits qui selon le jugement exclusif de Franklin Electric Company Inc ont t expos s la n gligence l abus un accident une application inappropri e une alt ration une modification ni aux dommages caus s par une installation une utilisation un entretien ou un entreposage inad quat ni a une utilisation au dela des maximums recommand s tel qu il est indiqu dans les instructions Les demandes de service couvert par cette garantie doivent tre faites en contactant Franklin Electric par telephone au 1 888 271 1370 pour obtenir une autorisation de retour de marchandise NE PAS RETOURNER LE PRODUIT AU MAGASIN OU ILA ETE ACHETE Franklin Electric fournira les instructions pour retourner le produit frais de transport pr pay s au d partement de la garantie de Franklin Electric avec votre regu d achat Cette garantie stipule l unique obligation de Franklin Electric et le recours exclusif de l acheteur pour un produit
6. LAISSER LE COUVERCLE DU BOITIER DU MOTEUR EN PLACE LE RETRAIT DU COUVERCLE DU BOITIER DU MOTEUR DE LA TURBINE OU DES JOINTS ANNULE LA GARANTIE TOUTE REPARATION DU MOTEUR DOIT ETRE EFFECTUEE A UN CENTRE DE SERVICE AUTORISE 7 Assurez vous que le cordon d alimentation est en bon tat et ne pr sente ni entaille ni coupure INTRODUCCI N Esta hoja de instrucciones le proporciona la informaci n requerida para tener y operar de forma segura su producto Coleman Guarde las instrucciones para referencia futura El producto Coleman que ha adquirido se fabrica utilizando mano de obra y materiales de la m s alta calidad y ha sido dise ado para prestarle un servicio duradero y confiable Los productos Coleman son cuidadosamente probados inspeccionados y empacados para garantizarle una entrega y operaci n seguras Examine su unidad cuidadosamente para asegurarse de que no haya ocurrido ning n da o durante el transporte Si se ha presentado alg n da o comun quese con el lugar de compra Deber n darle asistencia para obtener la reparaci n o reemplazo si se requiere LEA ESTAS INSTRUCCIONES CUIDADOSAMENTE ANTES DE INTENTAR INSTALAR HACER FUNCIONAR O PRESTAR SERVICIO T CNICO A SU PRODUCTO COLEMAN CONOZCA CUALES SON LAS APLICACIONES LIMITACIONES Y PELIGROS POTENCIALES DE LA UNIDAD PROTEJA A TERCEROS Y PROTEJASE A USTED MISMO SIGUIENDO TODA LA INFORMACI N DE SEGURIDAD LA FALTA DE CUMPLIMIENTO DE ESTAS INSTRUCCIONES PUE
7. d fectueux AVIS DE NON RESPONSABILIT Toute d claration verbale portant sur le produit faite par le vendeur le fabricant les repr sentants ou toute autre partie ne constitue pas une garantie et ne peut tre consid r e par l utilisateur comme faisant partie du contrat de vente La seule obligation du vendeur ou du fabricant et le seul recours de l acheteur est le remplacement et ou la r paration du produit par le fabricant comme il est d crit ci dessus Le vendeur ou le fabricant ne peut tre tenu responsable pour toute blessure perte ou dommage direct indirect ou cons cutif incluant mais sans s y limiter les dommages indirects ou cons cutifs li s la perte de profits la perte de ventes les blessures ou les dommages mat riels ou tout autre incident ou perte cons cutive r sultant de l utilisation ou de l impossibilit d utiliser le produit et l utilisateur accepte qu aucun autre recours n est disponible Avant de commencer utiliser le produit l utilisateur doit d terminer si ce produit est adapt l usage pr vu et l utilisateur assume toutes les responsabilit s qui sont li es cette utilisation La garantie et les mesures correctives d crites dans la pr sente garantie limit e constituent une garantie et des mesures correctives exclusives en lieu et place de toute autre garantie et mesure corrective expresse ou implicite et toute autre garantie et mesure corrective sont express ment exclues
8. es suficiente el hilo de 14 AWG Para extensiones mayores consulte a un electricista o a la f brica 6 La bomba debe estar conectada o cableada a su propio circuito sin ninguna otra salida o equipo en la l nea del circuito Los fusibles y el disyuntor deben ser de capacidad amplia en el circuito el ctrico 7 El ensamblaje de cable flexible con cubierta de PVC que est montado en la bomba no se debe modificar a menos que se acorte el cable para ajustarlo a un panel de control Cualquier empalme entre la bomba y el panel de control se debe hacer dentro de una caja de conexi n y se debe montar fuera del recipiente y debe cumplir con el C digo El ctrico Nacional CONSULTE LAS ILUSTRACIONES DE LA HOJA DE INSTRUCCIONES PARA MONTAR Y DESMONTAR CORRECTAMENTE SU BOMBA FUNCIONAMIENTO E y ADVERTENCIA 1 La bomba se debe instalar en un recipiente herm tico a gas adecuado que tenga un di metro de al menos 18 y una profundidad de 24 y que tenga ventilaci n seg n los c digos de plomer a locales 2 La bomba viene con una descarga de NPT hembra de 112 3 La bomba debe colocarse sobre una superficie dura nivelada Nunca coloque la bomba directamente sobre superficies de arcilla tierra o grava 4 Una v lvula de verificaci n debe ser usada en la l nea de descarga para impedir que el l quido se regrese al recipiente La v lvula de verificaci n debe ser una v lvula de flujo libre por la cual puedan pasa
9. from defects in material or workmanship If within the duration of product use by the product owner Coleman model 33 ASEP 50 ASEP proves to be defective the product shall be repaired or replaced at the option of Franklin Electric Company Inc subject to the terms and conditions set forth below GENERAL TERMS AND CONDITIONS This warranty shall not apply to acts of God normal wear and tear nor shall it apply to products which in the sole judgment of Franklin Electric Company Inc have been subject to negligence abuse accident misapplication tampering alteration nor due to improper installation operation maintenance or storage nor to excess of recommended maximums as set forth in the instructions Requests for service under this warranty shall be made by contacting Franklin Electric Company Inc via telephone at 1 888 271 1370 to obtain Return Merchandise Authorization DO NOT RETURN PRODUCT TO STORE WHERE PURCHASED Franklin Electric will provide instructions for returning freight prepaid to Franklin Electric s warranty department along with your purchase receipt This warranty sets forth Franklin Electric s sole obligation and purchaser s exclusive remedy for defective product DISCLAIMER Any oral statements about the product made by the seller the manufacturer the representatives or any other parties do not constitute warranties shall not be relied upon by the user and are not part of the contract for sale Sell
10. plug can be removed and switch operation can be observed 1 Plug power cord into a grounded receptacle with voltage consistent with pump voltage as indicated on pump nameplate 2 Run water into pump until pump starts 3 Be sure gate valve in discharge line is open 4 Allow pump to operate through several on off cycles SERVICE INSTRUCTIONS MAKE CERTAIN THE PUMP IS DISCONNECTED FROM THE POWER SOURCE BEFORE ATTEMPTING TO SERVICE OR REMOVE ANY COMPONENT 1 If pump does not operate properly consult the Troubleshooting table If trouble cannot be located with these steps shown return pump to Menards 2 This pump is permanently lubricated Oiling is not required Do not in any case open the sealed portion of the pump or remove housing screws 3 Periodic cleaning of the pump parts will prolong the life and efficiency of the pump Refer to the assembly and disassembly of the pumping head 4 Remove screws that hold base to volute and clean impeller and volute passage Do not use strong solvents on impeller 5 Be sure impeller turns freely after cleaning 6 WARNING DO NOT REMOVE IMPELLER REMOVAL OF IMPELLER REQUIRES SPECIAL TOOLS AND IS TO BE DONE ONLY BY AN AUTHORIZED SERVICE CENTER DO NOT REMOVE MOTOR HOUSING COVER WARRANTY IS VOID IF MOTOR HOUSING COVER IMPELLER OR SEALS HAVE BEEN REMOVED ANY REPAIR ON MOTOR MUST BE DONE BY AN AUTHORIZED SERVICE CENTER 7 Be certain power cord is in good condition and contains n
11. une capacit suffisante pour le circuit lectrique 7 L ensemble du cordon gaine en PVC souple mont la pompe ne doit tre modifi en aucune fa on Il peut au plus tre raccourci pour pouvoir p n trer dans le panneau de contr le Tout raccord entre la pompe et le panneau de contr le doit tre r alis dans une bo te de jonction et mont l ext rieur du bassin il doit galement tre conforme la r glementation du Code national de l lectricit LIRE ATTENTIVEMENT LE MODE D EMPLOI AVANT LE MONTAGE OU LE DEMONTAGE DE LA POMPE FONCTIONNEMENT E y AQ AVERTISSEMENT dh 1 La pompe doit tre install e dans un bassin antibact rien d un diam tre d au moins 18 po et d une profondeur d au moins 24 po Le filtrage bact rien du bassin doit tre conforme aux codes de plomberie locaux 2 La pompe est dot e d un raccord de refoulement NPT femelle de 1 po 1 2 3 La pompe doit tre install e sur une surface dure N installez jamais la pompe sur une surface argileuse terreuse ou sableuse 4 Vous devez installer un clapet de retenue dans la canalisation de refoulement afin de pr venir le retour du liquide dans le bassin Le clapet de retenue doit permettre le libre coulement de fa on laisser passer facilement les solides ATTENTION Installez le clapet de retenue l horizontale ou selon un angle d au plus 45 o afin de permettre un meilleur passage des solides et par cons quent un meilleur re
12. DE PRODUCIR LESIONES PERSONALES Y O DA OS A LA PROPIEDAD DESCRIPCION La bomba que ha comprado es una bomba efluente sumergible para uso en recipientes o en estaciones ascensoras y es adecuada para bombear aguas de alcantarillas efluentes aguas de desperdicio y otros l quidos no explosivos y no corrosivos con s lidos esf ricos de hasta 1 2 pulgada REGLAMENTO DE SEGURIDAD A ADVERTENCIA Cerci rese de que la unidad se encuentra desconectada de la fuente de electricidad antes de tratar de reparar o quitar cualquier pieza No use la unidad para bombear liquidos inflamables ni explosivos tales como gasolina fueloil queroseno etc No se use en ambientes explosivos o lugares epligrosos segun la clasificacion del codigo electrico nacional NEC y la norma NFPAT del Instituto Nacional Norteamericano de Normas No use la unidad en ambientes explosivos La bomba se debe usar con liquidos compatibles con los materiales de los componente de la bomba No manipule la bomba con las manos mojadas ni mientras se encuentre en una superficie mojada o hu meda o entre el aqua No saque la bomba del agua tirando del cable de potencia especialmente cuando la bomba est en funcionamiento o cuando est conectada a la fuente de potencia Esta bomba se suministra con un conductor a tierra y o un enchufe de conexion de tipo de conexion a tierra Para reducir el riesgo de descarga electrica asegurese de conectar la unidad a un
13. TRO DE SERVICIO AUTORIZADO NO QUITE LA CUBIERTA DE LA CAJA DEL MOTOR LA GARANTIA ES NULA SI SE QUITA LA CUBIERTA DE LA CAJA DEL MOTOR EL IMPULSOR O LOS OBTURADORES CUALQUIER REPARACION DEL MOTOR DEBE HACERSE EN UN CENTRO DE SERVICIO AUTORIZADO 7 Aseg rese de que el cable de potencia est en buenas condiciones y que no tenga cortes o rasgaduras TROUBLESHOOTING INFORMATION INFORMATION SUR LA REL VE DES DERANGEMENTS INFORMACION DE INVESTIGACION DE AVERIAS PROBLEM FONCTIONNEMENT PROBABLE CAUSES CAUSES PROBABLES CORRECTIVE ACTION SOLUTIONS DEFECTEUX PROBLEMA e CAUSAS PROBABLES SOLUCION Pump does not turn on La pompe ne peut tre mise sous tension La bomba no se activa Pump will not shut off Le moteur de la pompe ne s arr te pas La bomba no se apaga Pump runs but does not discharge liquid La pompe fonctionne mais il n y a pas d coulement de liquide La bomba funciona pero no descarga l quido Pump does not deliver rated capacity La pompe ne pompe pas le volume normal La bomba no impele a su capacidad normal Pump cycles continually La pompe recommence son cycle sans s arr ter La bomba se enciende y apaga continuamente Water sprays out of a hole by a bolt on the base of the unit L eau gicle de l orifice d un boulon situ la base de l appareil Sale agua expulsada a trav s de un orificio con trolado por un perno en la base la unidad Pump hot plug
14. arga del motor debida a un voltaje demasiado alto o bajo un cableado inadecuado conexiones de motor incorrectas o un motor o bomba defectuosos CONEXIONES ELECTRICAS fi Y E rA ADVERTENCIA 42 1 Consulte el r tulo de la bomba para conocer el voltaje adecuado que se requiere No la conecte a un voltaje distinto del indicado 2 Si la bomba est dotada de un enchufe el ctrico de tres dientes el tercer diente es para ponerla a tierra con el fin de prevenir el peligro de posibles choques el ctricos NO QUITE el tercer diente del enchufe Se recomienda un circuito de ramal independiente No utilice cables de extensi n No corte el enchufe del cable Si se corta el enchufe o se acorta el cable la garanti ser nula 3 Si el cable viene dotado de hilos conductores forrados como ocurre en los modelos de 230 voltios cerci rese de que los hilos conductores se encuentren conectados correctamente a una fuente de electricidad El hilo verde o amarillo es el de puesta a tierra el hilo azul o blanco y el marr n o negro son hilos con corriente 4 Verifique los c digos locales de construcci n y el ctricos antes de la instalaci n La instalaci n debe estar de acuerdo con los reglamentos as como con el C digo El ctrico Nacional National Electrical Code NEC m s reciente 5 Para cumplir con el C digo El ctrico Nacional se deben cablear todas las bombas con hilo de 14 AWG o m s grande Para extensiones de hasta 250 pies
15. cept culo conectado a tierra con un voltaje que sea consistente con el voltaje de la bomba como se indica en la placa de nombre de la bomba 2 Deje entrar agua dentro de la bomba hasta que empiece a funcionar 3 Aseg rese de que la v lvula de compuerta en la l nea de descarga est abierta 4 Permita que la bomba ejecute varios ciclos de apagado y encendido INSTRUCCIONES DE SERVICIO fi g E Al ADVERTENCIA ASEGURESE DE QUE LA UNIDAD ESTE DESCONECTADA DE LA FUENTA DE ALIMENTACION ELECTRICA ANTES DE INTENTAR PRESTAR SERVICIO A LA UNIDAD O QUITAR CUALQUIER COMPONENTE DE ELLA 1 Si la bomba no funciona apropiadamente consulte el plano de investigaci n de aver as Si no puede encontrar el problema siguiendo estos pasos lleve la bomba a Menards 2 Esta unidad se encuentra lubricada permanentemente No se requiere lubricaci n Jam s en ning n caso abra la parte de la unidad que est sellada o retire los tornillos de la caja 3 Una limpieza peri dica de las piezas de la bomba prolongar la VIDA y EFICIENCIA de la bomba Vea para montar y desmontar la cabeza de bombeo 4 Quite los tornillos que sostienen la base de la voluta y limpie el impulsor y el pasaje de la voluta No use solventes fuertes en el impulsor 5 Aseg rese de que el impulsor gire libremente antes de limpiarlo 6 ADVERTENCIA NO QUITE EL IMPULSOR PARA QUITAR EL IMPULSOR SE REQUIEREN HERRAMIENTAS ESPECIALES Y ESTO DEBE HACERSE SOLO EN UN CEN
16. dad durante un minuto aproximadamente Luego vu lvala a conectar Repita varias veces para purgar el aire de la bomba Turn on circuit breaker or replace fuse Mettez le disjoncteur sous tension ou remplacez le fusible Active el disyuntor o reemplace el fusible Float obstruction Flotteur bloqu Obstrucci n del flotador Defective switch Interrupteur d fectueux Interruptor defectuoso Defective motor e Moteur d fectueux Motor defectuoso Float or float rod obstruction Flotteur bloqu ou tige du flotteur bloqu e Obstrucci n del flotador o de la barra del flotador Pump is air locked Poche d air dans la pompe Burbujas de aire en la bomba Liquid inflow matches pump capacity Afflux de liquide correspondant au volume de la pompe El caudal que entra es igual a la capacidad de la bomba Larger pump required Une pompe plus puissante est n cessaire Se requiere una bomba mayor Disconnect switch check w ohmmeter Open infinitive resistance closed zero D brancher le commutateur v rifier avec un ohmm tre Ouvert r sistance infinitive ferm z ro Desconecte el interruptor e inspecci nelo con el ohmimetro abierto resistencia infinita cerrado cero Defective switch e Commutateur d fectueux Interruptor defectuoso Check flow indicating arrow on check valve body to ensure it is installed properly e V rifier la fl che indiquant l coulement pour s assurer que la so
17. dimiento normal de la bomba Check for proper supply voltage to make certain it corresponds to nameplate voltage e S assurer que le voltage correspond bien celui mentionn sur la plaque Verifique que el suministro de electricidad sea adecuado para cerciorarse de que corresponde al voltaje indicado en la placa del fabricante Low voltage speed too slow Voltage et vitesse pas assez puis sants Voltaje demasiado bajo velocidad demasiado baja Impeller or discharge pipe is clogged Obstruction de la roue a Pull pump and clean Check pipe for scale or corrosion Tirer la pompe pour la aubes ou du tuyau d coulement La rueda m vil en el tubo de nettoyer V rifier la pr sence de d p ts ou de corrosion dans les tuyaux Saque la descarga est oclu da bomba y l mpiela Inspeccione el tubo en busca de capas de xido o corrosi n Impeller wear due to abrasives Usure de la roue a aubes due aux Replace worn impeller e Remplacer la roue aubes us e Cambie la rueda abrasifs e Desgaste de la rueda m vil debido a abrasivos m vil gastada No check valve in long discharge pipe allowing liquid to drain back into sump Absence de soupape d arr t dans le grand tuyau d coulement ainsi permettant l coulement du liquide dans le puisard de r ception Falta la v lvula de retenci n en el tubo de descarga largo lo cual permite que el l quido refluya a la sumidero Install a check valve in discharge line
18. er s and manufacturer s only obligation and buyer s only remedy shall be the replacement and or repair by the manufacturer of the product as described above Neither seller nor the manufacturer shall be liable for any injury loss or damage direct incidental or consequential including but not limited to incidental or consequential damages for lost profits lost sales injury to person or property or any other incidental or consequential loss arising out of the use or the inability to use the product and the user agrees that no other remedy shall be available to it Before using the user shall determine the suitability of the product for his intended use and user assumes all risk of liability whatsoever in connection therewith The warranty and remedy described in this limited warranty is an exclusive warranty and remedy and is in lieu of any other warranty or remedy expressed or implied which other warranties and remedies are hereby expressly excluded including but not limited to any implied warranty of merchantability or fitness for a particular purpose Some states do not allow the exclusive or limitation of incidental or consequential damages so the above limitation or exclusion may not apply to you This warranty gives you specific legal rights and you may also have other rights which vary from state to state JOINDRE LE RECU ORIGINAL ICI POUR UNE REQUETE EN GARANTIE Franklin Electric Company Inc garantit les produits sp cifi
19. ewspapers on the water surface to soak up the oil The pump motor is equipped with an automatic resetting thermal protector and may restart unexpectedly Protector tripping is an indication of motor overloading as a result of excessively high or low voltage inadequate wiring incorrect motor connections or a defective motor or pump ELECTRICAL CONNECTIONS 1 Check the pump label for proper voltage required Do not connect to voltage other than that shown 2 If pump is supplied with a 3 prong electrical plug the third prong is to ground the pump to prevent possible electrical shock hazard DO NOT REMOVE the third prong from the plug A separate branch circuit is recommended Do not use an extension cord Do not cut plug from the cord If the plug is cut or the cord is shortened then this action will void the warranty 3 If the cord is equipped with stripped lead wires such as on 230 V models be sure that the lead wires are connected to a power source correctly The green yellow wire is the ground The blue or white and brown or black are live 4 Check local electrical and building codes before installation The installation must be in accordance with their regulations as well as the most recent National Electrical Code NEC 5 To conform to the National Electrical Code all pumps must be wired with 14 AWG or larger wire For runs to 250 14 AWG wire is sufficient For longer runs consult a qualified electrician or the fac
20. ged in La pompe n est pas branch e La bomba Plug in pump Branchez le puisard Enchufar la bomba no est enchufada Circuit breaker shut off or fuse removed Disjoncteur coup ou fusible enlev Desactivaci n del disyuntor o se ha retirado el fusible Accumulation of trash on float e Accumulation de d bris sur le flot Clean float Nettoyez le flotteur Limpie el flotador teur e Acumulaci n de desperdicios en el flotador i y P Check float path and provide clearance V rifiez la voie de passage du flotteur et d gagez la au besoin Verifique el flotador y proporcione espacio limpio Have pump serviced by authorized service center Faites r parer la pompe un centre de service autoris Lleve la bomba a un centro de servicio autorizado Have pump serviced by authorized service center Faites r parer la pompe un centre de service autoris Lleve la bomba a un centro de servicio autorizado Check float and float rod path and provide clearance V rifiez la voie de passage du flotteur et de la tige du flotteur et d gagez les au besoin Verifique el flotador y el trayecto de la barra de flotaci n y proporcione espacio limpio Shut power off for approximately 1 minute then restart Repeat several times to clear air from pump Couper le courant pendant 1 minute environ puis recommencer R p ter cette op ration plusieurs fois pour vacuer l air de la pompe Desconecte la electrici
21. he d aiimentation lectrique trois broches la troisi me est destin e raccorder la pompe la terre pour liminer les risques d electrocution NE PAS ENLEVER cette troisi me broche du cordon d alimentation Un circuit de branche s par est recommand Ne pas utiliser un prolongateur Ne pas couper la fiche du cordon Couper la fiche ou raccourcir le cordon entraineral annulation de la garantie 3 Si le cordon est muni de conducteurs codes l aide de rayures comme pour les mod les en 230 volts s assurer que ces fils sont correctement raccord s la source d alimentation lectrique Ainsi le fil vert jaune est pr vu pour le retour a la terre alors que les deux autres bleu ou blanc sont sous tension 4 V rifiez la r glementation locale en mati re d lectricit et de b timent avant de proc der l installation L installation doit respecter cette r glementation ainsi que le Code national de l lectricit le plus r cent 5 En conformit avec le Code national de l lectricit toutes les pompes doivent tre raccord es l aide de fils AWG 14 ou plus Pour un parcours de 250 pieds les fils AWG 14 sont suffisants Pour un parcours plus long consultez un lectricien professionnel ou l usine 6 La pompe doit tre connect e ou reli e son propre circuit lequel ne doit inclure aucune autre prise de courant ni d autre quipement Les fusibles et les disjoncteurs doivent tre dot s d
22. inar la idoneidad del producto para el uso propuesto y asumir todos los riesgos de responsabilidad que ello implique La garant a y recurso descritos en esta garant a limitada representan una garant a y recurso exclusivos y se ofrecen en lugar de cualquier otra garant a o recurso expl cito o impl cito en que todas las dem s garant as y recursos se excluyen expl citamente por este medio incluso pero sin limitarse a cualquier garant a impl cita de comercializaci n o idoneidad para un prop sito espec fico Algunos estados de los ee Uu No permiten la exclusi n o limitaci n de da os incidentales o emergentes por lo que puede que la limitaci n o exclusi n anterior no se aplique a usted Esta garant a le otorga a usted derechos legales espec ficos y es posible que usted tambi n tenga OTROS DERECHOS QUE VAR AN SEGUN EL ESTADO DE LOS EE UU For customer service please contact 1 888 271 1370 Pour le service clientele veuillez composer le 1 888 271 1370 Para servicio al cliente por favor llame al 1 888 271 1370 www colemanpumps com customerservice colemanpumps com 2013 The Coleman Company Inc All rights reserved Coleman and are registered trademarks of The Coleman Company Inc used under license Manufactured by Franklin Electric Company Inc Oklahoma City OK 73157 2010 2013 The Coleman Company Inc Tous droits r serv s Coleman et ET sont des marques de commerce d
23. incluant mais sans s y limiter toute garantie implicite de qualit marchande ou d adaptation un usage particulier Certaines juridictions interdisent les limitations et les exclusions des dommages indirects ou cons cutifs les limitations ou exclusions ci dessus pourraient donc ne pas s appliquer votre cas Cette garantie vous donne des droits l gaux sp cifiques et vous pourriez galement jouir d autres droits qui varient selon les juridictions ANEXE LA FACTURA ORIGINAL AQU PARA QUE SE CONSIDERE LA GARANT A Franklin Electric Company Inc garantiza que los productos especificados en esta garant a est n libres de defectos en los materiales y en la mano de obra Si durante el uso del producto por el propietario el modelo 33 ASEP 50 ASEP de Coleman resultan defectuosos stos ser n reparados o reemplazados seg n el criterio de Franklin Electric Company Inc sujeto a los t rminos y condiciones estipulados a continuaci n T RMINOS Y CONDICIONES GENERALES Esta garant a no tiene efecto si los da os se deben a fuerza mayor desgaste por uso normal como tampoco tendr vigencia en aquellos productos que a nico juicio de Franklin Electric Company Inc hayan sido sujetos a negligencia abuso accidente mal uso manipulaci n indebida alteraci n o a instalaci n funcionamiento mantenimiento o almacenamiento indebido o que sufran excesos de los m ximos valores recomendados estipulados en estas instrucciones
24. irectly on clay earth or gravel surfaces 4 Acheck valve must be used in the discharge line to prevent back flow of liquid into the basin The check valve should be a free flow valve that will easily pass solids CAUTION For best performance of check valves when handling solids install in a horizontal position or at an angle of no more than 45 Do not install check valve in a vertical position as solids may settle in valve and prevent opening on start up 5 Do not attempt to restrict the intake side of these pumps Restricting the intake may cause damage to the seal and may starve the pump If you require reduced flow rates then place a valve on the discharge side of the pump or if flexible vinyl tubing is used a clamp can be used on the tubing to restrict the flow 6 Do not let the pump run dry without liquid It is designed to be cooled by pumping fluid You may damage the seal and the motor may fail if the pump is allowed to run dry 7 lf the pump is going to be idle for a period of time follow the cleaning instructions outlined in the next section Do not let the pump freeze in the wintertime This may cause cracking or distortion that may destroy the pump TESTING 4 NOTE These pumps are equipped with a float operated mechanical switch NOTE When these pumps are installed in a basin with a sealed cover switch operation cannot be observed The sump cover usually will have a spare that is plugged with a rubber plug This
25. l kerosene etc DO NOT use in explosive atmospheres or hazardous locations as classified by NEC ANSI NFPAT Pump should be used with liquids compatible with pump component materials Do not handle the pump with wet hands or when standing on a wet or damp surface or in water Do not pull the pump out of the water by the power cord especially when the pump is operating or connected to power source This pump is supplied with a grounding conductor and or grounding type attachment plug To reduce the risk of electrical shock be certain that it is connected to a properly grounded grounding type receptacle The National Electric Code requires a ground fault circuit interrupter GFCI be installed in the branch circuit supplying fountain equipment pools etc In any installation where property damage and or personal injury might result from an inoperative or leaking pump due to power outages discharge line blockage or any other reason a back up system s and or alarm should be used Support pump and piping when assembling and when installed Failure to do so may cause piping to break pump to fail motor bearing failures etc This pump s motor housing is filled with a dielectric oil for motor heat transfer and lifetime lubrication of the bearings This oil is non toxic to aquatic life However suffocation can occur if oil is left on the water surface If oil escapes the motor housing it can be removed from the surface quickly by placing n
26. ndement du clapet N installez pas le clapet de retenue la verticale cette position pourrait provoquer le blocage des solides dans le clapet et son ouverture au d marrage 5 Ne pas laisser fonctionner la pompe sec ce qui pourrait endommager le joint et provoquer une panne de moteur car elle est con ue pour tre refroidie par le liquide pomp 6 Ne laissez pas l appareil fonctionner sec sans liquide Il est con u pour se refroidir en pompant un liquide Vous pouvez endommager le joint et le moteur peut tomber en panne si vous laissez la pompe tourner vide 7 Si l appareil doit rester inutilis pendant un certain temps suivez les instructions de nettoyage ci dessous Ne laissez pas l appareil geler Cela peut entrainer des f lures ou des d formations qui d truiraient l appareil V RIFICATION W Au MNERTISSEMENT NOTE Ces pompes sont munies d un interrupteur m canique actionn par flotteur NOTA Lorsqu une pompe de ce type est install e dans un bassin pourvu d un couvercle tanche il est impossible d observer le fonctionnement de l interrupteur Le couvercle du puisard est habituellement pourvu d une ouverture suppl mentaire ferm e l aide d un bouchon de caoutchouc ll est possible d enlever ce bouchon et d observer le fonctionnement de l interrupteur 1 Branchez le cordon d alimentation dans une prise bipolaire avec borne de terre dont le voltage convient celui de la
27. o nicks or cuts G gt INTRODUCTION Cette feuille d instructions vous fournit les informations n cessaires pour entretenir et faire fonctionner votre produit Coleman Conserver ces 2 directives afin de pouvoir les consulter plus tard Le produit Coleman que vous avez achet a t soigneusement fabriqu avec des mat riaux de la plus haute qualit et a t concu pour durer longtemps et offrir un service fiable Les produits Coleman sont soigneusement test s inspect s et emball s afin d en assurer la s curit de fonctionnement et une livraison en bonne condition V rifier attentivement le produit afin de vous assurer qu il n a pas t endommag pendant le transport S il est endommag veuillez contacter l entreprise qui vous l a vendu Si une r paration ou un remplacement est requis elle vous pr tera assistance LIRE ATTENTIVEMENT CES DIRECTIVES AVANT DE PROC DER L INSTALLATION A L UTILISATION OU A L ENTRETIEN DU PRODUIT COLEMAN SE FAMILIARISER AVEC LES APPLICATIONS LES LIMITES ET LES RISQUES POTENTIELS DU PRODUIT ASSURER SA PROPRE PROTECTION ET CELLE DES AUTRES EN SUIVANT TOUTES LES REGLES DE SECURITE LE NON RESPECT DE CES DIRECTIVES PEUT ENTRAINER DES BLESSURES ET OU DES DOMMAGES MATERIELS DESCRIPTION Vous avez achet amp une pompe pour effluent submersible pouvant tre utilis e dans des bassins ou dans des stations de pompage des eaux us es Elle permet de pomper les eaux d gout l effl
28. pompe Le voltage de la pompe est indiqu sur la plaque signal tique 2 Faites couler de l eau dans la pompe jusqu ce que celle ci d marre 3 Assurez vous que le clapet de la vanne l intrieur de la canalisation de refoulement est ouvert 4 Faites fonctionner la pompe pendant plusieurs cycles d marrage arr t DIRECTIVES D ENTRETIEN Kid E y AR AVERTISSEMENT 4h VOTRE POMPE DEMANDERA TR S PEU D ENTRETIEN SI POUR UNE RAISON QUELCONQUE ELLE NE PEUT PAS FONCTIONNER SUIVEZ LES INSTRUCTIONS CI DESSOUS 1 Si la pompe ne fonctionne pas convenablement consultez le tableau de rel ve des d rangements Si vous pouvez identifier le probl me en suivant les tapes indiqu es consultez Menards 2 Cette unit est lubrifi e en permanence Il n est pas n cessaire de la graisser N ouvrez jamais la partie scell e de l unit et n enlevez jamais les vis du boitier 3 Le nettoyage p riodique de la pompe augmentera sa dur e de vie et son efficacit Consultez la savoir comment assembler et d monter la t te de pompage 4 Retirez les vis qui relient la base a la volute puis nettoyez la turbine et le passage de la volute N utilisez aucun solvant puissant sur la turbine 5 Veillez a ce que la turbine tourne librement une fois le nettoyage termin 6 AVERTISSEMENT LAISSEZ LA TURBINE EN PLACE LE RETRAIT DE LA TURBINE NECESSITE DES OUTILS SPECIAUX ET NE PEUT ETRE EFFECTUE QU A UN CENTRE DE SERVICE AUTORISE
29. r s lidos f cilmente ADVERTENCIA Para un mejor funcionamiento de las v lvulas de verificaci n instale en posici n horizontal o a un ngulo de no m s de 45 grados al manejar s lidos No instale la v lvula de verificaci n en posici n vertical ya que los s lidos se pueden quedar en la v lvula e impedir la apertura en el momento de activaci n 5 No permita que la unidad funcione en seco Est dise ada para que la enfrien los liquidos bombeados Si se permite que la bomba funcione en seco puede estropearse el obturador y el motor puede caerse 6 No deje que la unidad en operacin se quede sin agua Esta dise ada para ser enfriada por medio del bombeo de liquido Usted puede da ar el sello y el motor puede fallar si se permite que la bomba opere sin agua 7 Si la unidad se mantiene sin funcionar por un per odo de tiempo largo siga las instrucciones de limpieza descritas en la pr xima secci n No permita que la unidad se congele Esto puede causar agrietamiento o deformaciones lo cual puede dest ruir la unidad COMPROBACION al MA A ADVERTENCIA NOTA Estas bombas est n equipadas con un interruptor mec nico operado por un flotador NOTA Cuando estas bombas se instalan en un recipiente con una cubierta obturada no hay manera de observar la operaci n del interruptor La cubierta de sumidero normalmente tiene un agujero de sobra que est tapado con un tap n de pl stico 1 Enchufe el cable de potencia a un re
30. receptaculo del tipo polarizado y adecuadamente conectado a tierra El C digo El ctrico Nacional National Electric Code requiere la instalaci n de un interruptor de circuito por falla a tierra GFCI en el ramal del circuito que suministra la corriente a fuentes piscinas etc En cualquier instalacion donde puedan ocurrir da os materiales y o lesiones personales que resulten del funcionamiento inadecuado o de fugas en la bomba a causa de fallos en la alimentacion electrica bloqueo de la linea de la descarga o cualquier otra razon se debera usar uno o varios sistemas de respaldo y o alarmas Apoye la bomba y la tuberia durante el ensamblado de la unidad y al completar la instalacion El no hacerlo asi puede causar la ruptura de la tuberia el fallo de la bomba el fallo de los cojinetes del motor etc El alojamiento del motor de esta bomba est lleno con un aceite diel ctrico para la transferencia de calor y la lubricaci n de por vida de los cojinetes Este aceite no es t xico para la vida acu tica Sin embargo puede ocurrir la muerte de sta si el aceite queda sobre la superficie Para quitar r pidamente el aceite que pueda haberse escapado del alojamiento del motor coloque peri dicos sobre la superficie del agua para absorber el aceite El motor de la bomba est equipado con un protector t rmico de reposici n autom tica y puede reposicionarse inesperadamente El accionamiento del protector es una indicaci n de sobrec
31. rotector del Cable de Potencia 2 or 3 Vent Pipe Canalisation de Ventilation de20u3po Tubo de Ventilaci n 2 6 3 Sump Cover Couvercle de Puisard 3 16 Dia Bleed Hole in Discharge Pipe Trou de d gagement diam 3 16 po sur le tuyau d coulement Agujero de purgado de 3 16 de di metro en la tuber a de descarga Cubierta del Sumidero fig j N 8 11 on level 8 po 11 po a niveau 8 a 11 en el nivel er Pump N ad ut RE TE 4 eae N Pompe 2 5 off level 2 po 5 po hors niveau pra Sepp 2 a 5 fuera del nivel Gas tight basin 18 dia amp 24 deep min Bassin antibact rien d un diametre minimal compris entre 18 po et 24 po Recipiente herm tico al gas de 18 di metro y de un m nimo de 24 de profundidad Place pump on hard level surface Never place directly on clay earth or gravel surface 7 La pompe doit tre install e sur une surface dure N installez jamais la pompe sur une surface argileuse terreuse ou sableuse Posicione la bomba sobre una superficie dura y nivelada y nunca posicione la bomba directamente sobre superficies de arcilla tierra o grava Fig 1 OPERATION 1 Pump must be installed in a suitable gas tight basin which is at least 18 in diameter and 24 deep and vented in accordance with local plumbing codes 2 Pump features a 1 1 2 female NPT discharge 3 Pump must be placed on a hard level surface Never place pump d
32. st recommand e pour toute installation potentiellement dangereuse fuite ou d fectuosit caus es par une coupure de courant un blocage du circuit de refoulement ou pour toute autre raison pour les personnes ou la propri t Immobiliser la pompe et les tuyaux lors de l installation et de l utilisation afin d viter tout risque de dommages aux tuyaux la pompe aux roulements bille du moteur etc Le bo tier du moteur de cette pompe est rempli d une huile di lectrique pour un transfert de chaleur optimal et une lubrification durable des paliers Cette huile n est d aucun danger pour la vie aquatique ll y a toutefois risque de suffocation si l huile reste la surface de l eau S il devait y avoir fuite retirer l huile de la surface en pla ant du papier journal sur l eau afin d absorber l huile Le moteur de la pompe est pourvu d un dispositif de protection thermique d marrage automatique elle peut red marrer tout moment Le d clenchement du dispositif de protection indique une surchauffe du moteur provoqu e par un voltage excessif ou insuffisant un c blage non appropri des erreurs de raccordement du moteur une d faillance du moteur ou une d faillance de la pompe CONNEXIONS LECTRIQUES W y AA AVERTISSEMENT 4h 1 Consulter l tiquette de la pompe pour conna tre la tension appropri e Ne pas raccorder une source autre que la tension sp cif e 2 Si la pompe est quip e d une fic
33. tory 6 Pump should be connected or wired to its own circuit with no other outlets or equipment in the circuit line Fuses and circuit breaker should be of ample capacity in the electrical circuit 7 The flexible PVC jacketed cord assembly mounted to the pump must not be modified in any way with the exception of shortening the cord to fit into a control panel Any splice between the pump and the control panel must be made within a junction box and mounted outside of the basin and comply with the National Electrical Code CONSULT INSTRUCTION SHEET ILLUSTRATIONS FOR PROPER ASSEMBLY AND DISSASSEMBLY OF YOUR PUMP Separate protected and grounded service outlet minimum 4 ft from floor Prise de courant de mise a la terre a protection separee a une distance minimale de 1 2m du sol Tomacorrientes de servicio conectado a tierra y protegido separado por lo menos a 1 2 m del suelo TYPICAL INSTALLATION gt An INSTALLATION TYPE liza Y INSTALACION TIPICA Emp Power Cord de la pompe Cable de potencia de la bomba r ag i 7 Gate Valve Clapet de la vanne FX V lvula de la compuerta Check Valve Clapet de retenue Verifique valvula Discharge pipe no smallerthan pump outlet La canalisation de refoulement doit etre plus petite que la sortie de pompe SS Tubo de descarga que no sea mas pequino que la salida de labomba Ne Power Cord Grommet Oeillet du Cordon d alimentation Anillo P
34. uent les eaux us es et d autres liquides non explosifs et non corrosifs pouvant contenir des solides d un diam tre de 1 2 po DIRECTIVES DE S CURIT W iz 42 AVERTISSEMENT dh Veiller a d brancher l appareil de sa source d alimentation lectrique avant l entretien ou la d pose d une ou de plusieurs pi ces Ne pas utiliser pour pomper des liquides explosifs ou inflammables essence huile kerosene etc Ne pas utiliser dans des environnements explosifs ou des lieux consid r s comme dangereux voir Code nat de l lect ANSI NFPAT Ne pas utiliser dans un environnement propice aux explosions Utiliser avec des liquides compatibles avec les mat riaux de la pompe Ne pas manipuler la pompe les mains humides les pieds pos sur une surface mouill e ou humide ou les pieds dans l eau N utilisez pas le cordon d alimentation pour sortir la pompe de l eau particuli rement alors que la pompe fonctionne ou qu elle est reli e une source d alimentation Votre pompe vient avec un fil de mise a la terre et ou une prise a trois branches Afin de r duire le rusque de choc lectrique s assurer que la pompe est branch e a une prise correctement mise a la terre Le Code national de l lectricit exige qu un interrupteur de mise a la terre GFI soit install sur le circuit d installation d une fontaine d une piscine etc L utilisation d un ou de plusieurs syst mes auxiliaires et ou d un systeme d alarme e
35. upape d arr t est bien mont e Inspeccione la flecha indicadora del flujo en el cuerpo de la v lvula de retenci n para cerciorase de que se encuentre instalada correctamente Check valve installed backwards Montage envers de la soup ape d arr t V lvula de retenci n montada al rev s Remove check valve and inspect for proper operation D monter et v rifier la soup ape d arr t pour un bon fonctionnement Quite la v lvula de retenci n y verifique que funcione debidamente Check valve stuck or plugged Soupape d arr t bloqu e ou obstru e V lvula de retenci n atorada u ocluida Lift too high for pump Aspiration trop puissante pour la pompe Altura de impulsi n excesiva para la bomba Inlet to impeller plugged Arriv e de la roue aubes obstru e a A E Toma de la rueda m vil conectada Pull pump and clean Tirer la pompe pour la nettoyer Saque la bomba y limpiela Pump is air locked Pr sence d une poche d air dans la pompe See corrective action above Voir ci dessus la solution Rem tase a la e La bomba est llena de burbujas de aire soluci n anterior Check rating table V rifier le tableau d valuation Estudie la tabla de capacidad Lift too high for pump Aspiration trop puissante pour la pompe Check rated pump performance V rifier les caract ristiques techniques de la Altura de impulsi n excesiva para la bomba pompe Verifique el ren
Download Pdf Manuals
Related Search
Related Contents
AfinionTM ACR • Quick Guide User manual - COMM-TEC Tecnoware Notebook Charger 120 Mio A701 GPS PDA Phone + MIOMAP BNL+MRE ACD01 Benutzerhandbuch Targus THZ334EU manual - kiddo HFS User Manual - Health Financial Systems refusol - Advanced Energy pdf Documentation language en size 0.74 MB Copyright © All rights reserved.