Home
Pedicure Spa Use & Care Manual
Contents
1. Yo CHECK VALVES DRAIN CAP D 1 x RED 3 8 COMP VALVES 54 SUCTION DRAIN PUMP 12 to 14 ABOVE FINISHED FLOOR BACKFLOW PREVENTER SPECIFICATIONS ZURN VACUUM BREAKER IAPMO Z7000 VB ASSE 1014 Fa amp SPA1000 CONCEPTS amp DESIGNS PEDICURE CHAIR PIPING amp INSTRUMENT DIAGRAM PIPE LESS SYSTEM WITH FLOOR DRAIN NOTES POWER SOURCE 110V AC 6 AMP 60 HZ GFI PROTECTED CONFORMS TO UL STD 1795 AND UL STD 73 MASSAGE CHAIR CERTIFIED TO CSA C 22 2 NO 218 1 AND CAN CSA C 22 2 NO 68 ZURN BACKFLOW PREVENTER VACUUM BREAKER Installed to spas shipped to MA amp CA Los Angeles area FILLER SHOWER AIR CONTROL HEAD w BACK FLOW FIBERGLASS KNOB PREVENTER MANUAL DRAIN SHELL ACTUATOR OVERFLOW AIR SWITCH POWER SUPPLY __ ___ MAX WATER LEVEL 5 GAL WITH TIMER 15 AMP RATED JET Xi JET LIGHT AIR SWITCH v 12 VOLT LED LIGHT y AX XXXX x J m s oe E a m s mm A DRAIN CAP d py H gt 3 8 COMP SLOPE at 1 4 per foot 1 1 2 DISCHARGE TO S S h VALVES 3 8 HOT WATER SUPPLY 12 14 3 8 COLD WATER SUPPLY ABOVE FINISHED
2. 16 Front View Tub Top View Spray Nozzle amp Spout Above water line to prevent back flow Drain On Off Hot amp Cold Control Mixer Overflow Controls Drain Jet Drain LED Light Preparing the Pedicure Spa for Operation Clean and disinfect the basin following the instructions on page 17 before initial use Operating the Pedicure Spa Add Water to the Pedicure Spa Basin 1 Turn the overflow knob counter clockwise until it stops to close drain 2 Lift upward on the hot amp cold control mixer to add water to the basin Turn the handle in a counter clockwise direction for cold water or clockwise for warm water as indicated by the red hot and blue cold markings under the handle Continue to add water until the fill line is reached The fill line is indicated by the wavy line in the basin CAUTION Always check water temperature before use hot water can burn skin and can cause serious injuries Water temperature should not exceed 105 F 41 C 3 Turn the off water by pushing the handle downward Start or stop the whirlpool by pressing the jet button Remove water from the Pedicure Spa Basin Make certain the whirlpool jets are turned off by pressing the jet button For use with a floor drain simply open the drain by turning the overflow knob in a clockwise direction until it stops You should see the water level lowering as water exits the basin For use with the optional d
3. aI OOO Pedicure Spa Use amp Care Manual J A Ve LA S RE ail W A IT IS IMPORTANT THAT YOU READ AND FOLLOW THESE INSTRUCTIONS Please keep this manual in a safe place FR JET WARRANTY PRE REGISTRATION IS REQUIRED TECH NO lr OC PLEASE SEE BACK COVER Safety Information 4 5 Cap o S L L L L Installation Information 6 7 A on your purchase of our pedicure spa Plumbing Installation 8 HT 1000 Chair Installation 9 You have made the right choice Our revolutionary Replacing the Controller PCB 10 11 products are designed to meet your needs HT 1000 Remote Features 12 13 Installing the New Armrest 14 Ji O O O proudly makes our goal to provide Liner Jet amp Liner Instructions 15 the Pedicure Spa Industry with quality products that surpass the minimum sanitation requirements of your local Basin Operation 16 area state boards We pride ourselves on our commitment to l l Cleaning Instructions 17 customer safety and satisfaction Use Care amp Maintenance 18 19 With proper care you and your customers can enjoy your Parts Identification Specifications 20 21 pedicure spa for many years to come Parts 22 23 Before installation and use of your pedicure spa please read the Warrranty Information 25 entire manual thoroughly If you encounter any questions or problems in regards to your pedicure spa please contact Spa1000 s Technical Support Department at 1 225 236 0
4. more if in dusty conditions Failure to follow this procedure will void warranty First remove chair cushions Locate zipper pull on bottom of chair Carefully cut off plastic zip tie blocking zipper suggested item Use white or yellow colored grease DO NOT use black Grease can be bought at any hardware or auto parts store Top view Also apply grease at the joints of robotic arms Apply grease along coiled pole and at the very bottom of pole Use remote to move mechanism down and grease top of pole 7 Replace mechanism cover and cushions 19 Parts Identification Floor Drain Ne Control Mixer N ef Jet amp Light Air Ar Swe a Air Control E Pipe Free Jet To Shower Head Overflow Swivel P Trap 12 V LED Light LED Light Transformer T4 3S1C Power Supply To Outlet 1 8 SS Braided 172 PVC to Hose Hot floor drain 3 8 compression 8 S S Braided Hose Cold 3 8 compression 20 Wall Drain Drain Pump Control Air Switch 8 SS Braided Hose Hot 3 8 compression To Outlet Mixer 1 Jet amp Light Air Switch a Jet To Shower Head Overflow Swivel P Trap 12 V LED Light Jet Transformer T4 2S1T1C Wall Drain Power Supply T4 DPH Drain Pump with check valve 8 S S Braided Hose Cold 3 8 compression 1 PVC Coupling to wall drain Specifications HT 1000 Chair Sp
5. FLOOR 3 HUB DRAIN LT 2 to 3 DRAIN TO SEWER SYSTEM BACKFLOW PREVENTER SPECIFICATIONS ZURN VACUUM BREAKER WITH AIR GAP IAPMO Z7000 VB ASSE 1014 ty NOTE 2 people are required to attach the chair to the spa basin Please do not attempt to do it by yourself Doing so may result in serious injuries or damage to the products Remove chair out of the box carefully make sure that you do not grab the armrest Lifting the chair incorrectly may cause damage to the chair Lift the bottom cover Plug chair in Move chair forward backward with remote control to clear the holes Align bolt holes in chair with holes in spa Begin to install 3 regular bolts into holes red arrows While one person holds the chair in place the second person flips up the bottom cover OO Wing Nut 6 Install bolt and washers in order shown here Hell Tighten wing nut Le to end of bolt by Flat Washer Lock Washer reaching under neath the chair Use a wrench to secure Bolt After placing the screws lock the backrest of chair by pushing the back until it locks To unlock the chair pull down lever Replacing the Controller PCB To ensure that Human Touch products are repaired in a manner that is consistent with the practices used during the manufacturing process Human Touch requires that all product repairs are performed using only factory new parts in accordanc
6. and thoroughly clean inside surface of spa basin with Sanitex disinfectant wipes 8 Thoroughly clean rest of the spa tub surface with Sanitex disinfectant wipes The unit is now ready for the first customer of the day Note DO NOT clean pedicure spa with pure chlorine solution DO NOT soak overnight with pure chlorine or chlorine solution This may lead to premature deterioration and rusting of the pedicure spa and its component parts and will result in void of limited warranty Recommended EPA Approved Hospital Grade Items Sanitex Spray Pa Sanitex Wipes Pedi Clear EPA Approved amp Hospital Grade EPA Approved amp Hospital Grade _ r Disinfectant Liquid or Crystals 3 EPA Approved Use amp Care 18 Note Failure to follow these necessary maintenance instructions will void warranty Chair Maintenance Lubrication is required on the drive shaft every 6 months Yellow or white grease sold at auto part stores can be used Please refer to pages 19 and 20 Greasing Drive Shaft for further instructions Remove dust on the backrest or armrest with a vacuum Do not use benzene thinner or any other solvents on your massage chair If the backrest or a armrests become soiled wipe with a damp cloth then a dry cloth Common vinyl cleaners may be used for tough stains Use a dry cloth only to clean the controller and around the power switch Foreign objects should not be inserted between the massage nodes or the unit hous
7. dans une des ouvertures du spa e Une stricte surveillance est n cessaire lorsque ce spa est utilis pour traiter des enfants des personnes invalides ou handicap es ou qu il est utilis par ou proche d eux Ne pas se tenir debout en ne laisser personne se tenir debout dans la cuve du spa On doit tenir compte du fait qu une cuve de spa remplie d eau constitue un risque possible de noyade V rifier la temp rature de l eau avant chaque utilisation la temp rature de l eau ne doit pas d passer 105 F 41 C et celle de l eau dans le r chauffeur ne doit pas d passer 150 F 65 C D sinfecter la cuve et les buses du spa apr s chaque usage l aide d un agent de nettoyage approuv viter de masser toute r gion du corps qui est enfl e irrit e ou couverte d ruptions cutan es Avant de mettre en marche la chaise de massage s assurer que les bras de la chaise sont abaiss s En cas de malaise grave pendant le massage arr ter le traitement et consulter un m decin Ne pas utiliser la chaise de massage pendant plus de 15 minutes la fois viter de mettre les mains ou les doigts pr s du m canisme ou des galets de massage pendant que la chaise fonctionne un contact avec ce m canisme risque d entra ner des blessures r sultant de l action de pincement des galets S assurer que la chaise de massage et ses ouvertures d air sont propres et exemptes de peluche de cheveux et de poussi re ne jamais
8. faire fonctionner la chaise de massage si les ouvertures d air sont obtur es ou bloqu es e Une mauvaise utilisation un abus ou un manquement nettoyer correctement le spa de p dicure peut se traduire par de graves probl mes de sant des bles sures et ou m me une mort accidentelle Mise en garde relative au risque pour la sant L usage du spa de p dicure devrait procurer des effets plaisants et de bien tre en cas d apparition de douleur ou de malaise on doit interrompre imm diatement l utilisation du spa Toute personne qui souhaiterait utiliser la chaise de massage doit consulter un m decin si elle est enceinte ou si elle souffre des troubles suivants tumeur maligne maladie cardiaque conditions exigeant le repos maux de dos chroniques ou probl mes imputables une blessure ou un accident Toute personne qui souhaite utiliser la cuve ou les buses du spa doit consulter un m decin si elle souffre des troubles suivants diab te enflures fracture ou douleurs persistantes Il est recommand toute personne pr sentant une irritation des pieds des plaies ouvertes ou des infections fongiques de ne pas utiliser la cuve et les buses du spa Une mauvaise utilisation un abus ou un manquement nettoyer correctement le spa de p dicure peut se traduire par de graves probl mes de sant des blessures et ou m me une mort accidentelle MISE EN GARDE DIRECTIVES ET M THODES DE MISE LA TERRE Ce spa doit tre mis l
9. 289 or info spa1000 net IMPORTANT Monday through Friday from 9 AM to 5 PM CST Please fill out and return warranty registration on back cover Registration is required After hours calls are recorded and will be responded not applicable in some states to the following business day Serial Number W O Number Purchase Date Copyright 2010 Spa1000 All Rights Reserved All brand and or product names and logos are trademarks or registered trademarks of their respective owner s keep it safe IMPORTANT SAFETY INSTRUCTIONS SAVE THESE INSTRUCTIONS AND PLEASE KEEP IN A SAFE PLACE Read all instructions before using this pedispa DANGER Risk of Electric Shock Connect only to a circuit protected by a ground fault circuit interrupter GROUNDING IS REQUIRED The unit should be installed by a qualified service representative and grounded Install to permit access for servicing CAUTION Risk of electric shock Disconnect electric power before servicing WARNING Risk of accidental injury or drowning Children should not use hydro massage bathtub without adult supervision WARNING Risk of accidental injury or drowning Do not use hydro massage bathtub unless all suction guards are installed to prevent body and hair entrapment WARNING To avoid injury exercise care when entering or exiting the hydro massage bathtub WARNING Risk of accidental injury or drowning do not use drugs or alcohol before or during the use of a
10. AND METHODS This unit must be grounded If it should malfunction or break down grounding provides a path of least resistance for electrical current to reduce the risk of electric shock All outlets connected to pedicure spas must include a GFCI device Ground Fault Circuit Interrupt er This will reduce the risk of electric shock This unit is for use on a standard 110 Volt 60Hz current This unit is equipped with a cord having an equipment grounding conductor and a grounding plug The plug must be plugged into an appropriate outlet that is properly installed and grounded in accordance with all local codes and ordinances If you are in doubt as to whether this unit is properly grounded check with a qualified electrician or serviceman Fatal electric shock and fire could occur with improper connection of the equipment grounding conductor Do not modify the plug provided with the product for any reason if it will not fit the outlet have a proper outlet installed by a qualified electrician WARNING THERMAL RESETTING PROTECTION DEVICE The massage chair is equipped with a thermal resetting protection device This is a safety feature to protect it from overheating If the chair should suddenly stop and will not start turn the main power switch off and do not operate the chair for at least 30 minutes Failure to turn the chair off may result in the chair starting unexpectedly when the device cools Information sur la s curit CONSERVER C
11. Activate by air switch 3 on off 1 continuous Activate by air switch LED Lights LED Light set T4 L18 Set includes 18 LED bulbs AC 12V transformer reflector housing nut amp gasket light holder Bulb T4 22 L18B and transformer T4 L18T also available separately Use with drain pump Wall Drain Power Supply Set includes 1 2 NPSM 1 2 NPSM Allows 1 direction flow to spray nozzle or filler spout for older spa designs Push Button Engraved Metal Push Button Tube Push Button T4 PBT 14 PBM 1 8 Clear tubing 500 Roll LED Light Set PRC T4 L18C 18 LED bulbs AC 12V transformer reflector housing nut amp gasket light holder Bulb T4 L18BC and transformer T4 L18TC also available separately Shower Head and Hose Shower Head Only T4 SH2HH Stainless Steel Hose Only D 74 SH2H _Shower Head Complete T4 SH2 ae if Includes shower head angle holder amp stainless steel hose Air Control Silent Air Control Air Control Tube Air Control Barbs T4 AC T4 ACT a o b For use with Geni Jet py FS Controls air mixed with water jet 3 8 100 roll a 3 8 barb x 1 2 spg b 3 8 barb tee T4 ACBY T4 ACBT Plumbing Accessories Level Controller with Solenoid Valve 1 14 Swivel P Trap T4 LCSV Overflow Assembly 8 Stainless Steel T4 SPT oe Braided Hoses T4 BHH Hot T4 BHC Cold Eliminates odors from drain 1 2 NP
12. Before operating the massage chair make sure the chair arms are down If there is severe discomfort during the massage discontinue use and consult a physician Do not use the massage chair for more than 15 minutes at one time Do not put hands or fingers near massage mechanism or rollers while the chair is operating touching the mechanism can result in injury from the roll ers squeezing together Keep the massage chair and its air openings clean and free of lint hair and dust never operate the massage chair if the air openings are blocked Misuse or failure to properly clean pedicure spa unit may result in serious health issues bodily injury and or death A Health Risk Warning Use of the pedicure spa unit should be pleasant and comfortable if there is any pain or discomfort stop use of the pedicure spa immediately A physician should be consulted before use of the massage chair by anyone with the following conditions Malignant tumor heart disease pregnancy Conditions requiring rest and back disease or trouble from an injury or accident A physician should be consulted before use of the spa basin and jets by anyone with diabetes swelling fracture or persistent pain Anyone with inflamed legs or feet open wounds or fungal infections should not use the spa basin and jets Misuse or failure to properly clean pedicure spa unit may result in serious health issues bodily injury and or death A warnine GROUNDING INSTRUCTIONS
13. E MODE D EMPLOI Avant d utiliser votre nouveau spa de p dicure veuillez lire et respecter attentivement ces consignes de s curit afin de r duire les risques de blessures de dommages corporels graves de mort accidentelle d incendie et ou d autres d g ts mat riels Pour des questions suppl mentaires veuillez vous adresser a notre service de soutien technique au 1 225 236 0289 MISE EN GARDE est tr s important de suivre scrupuleusement les proc dures de nettoyage de la cuve la page 17 afin d assurer que le spa soit aseptis apr s chaque utilisation Spa1000 ne peut en aucun cas tre tenue responsable de cas d infections ou de maladie pouvant d couler d un mauvais nettoyage ou d un manquement aux exigences de d sinfection e Ce spa de p dicure doit fonctionner uniquement des temp ratures ambiantes comprises entre 40 F 4 C et 100 F 38 C Ne pas utiliser le spa en ext rieur ou dans les milieux tr s humides ou poussi reux Ne pas utiliser le spa dans des endroits o l on emploie des produits en a rosol pulv risateur ou dans des endroits o on administre de l oxyg ne Ne pas faire fonctionner le spa s il a t endommag Connecter toujours ce spa une prise lectrique correctement mise la terre Ce spa est con u pour fonctionner seulement sur alimentation secteur de 110 Volts 60 Hz Le faire fonctionner des tensions sup rieures risque d entra ner de graves blessures et o
14. Installing the Rear Left hand Bolt Chair CD Flat washer 4 GHD Lock washer Hex headed Bolt Oo ia 3 1 Place the chair into position on top of the tub 2 Place the lock washer then the at washer onto the bolt 3 From beneath the tub thread the hex headed bolt upward through the rear left hand tub bolt hole Fig 3 4 Install the wing nut onto the end of the bolt then use a wrench to secure it Fig 3 Chair bar Tub Wall Drain Installation SPA1000 CONCEPTS amp DESIGNS PEDICURE CHAIR PIPING amp INSTRUMENT DIAGRAM PIPE LESS SYSTEM WITH WALL DRAIN NOTES POWER SOURCE 110V AC 6 AMP 60 HZ GFI PROTECTED ee EPP D CONFORMS TO EL UL STD 1795 AND UL STD 73 hi un CERTIFIED TO CSA C 22 2 NO 218 1 MASSAGE CHAIR R WALL nos AND CAN CSA C 22 2 NO 68 ZURN BACKFLOW PREVENTER VACUUM BREAKER Installed to spas shipped to MA amp CA Los Angeles area FILLER SHOWER AIR CONTROL HEAD w BACK FLOW ee ee a al FIBERGLASS KNOB PREVENTER MANUAL DRAIN 7 va SHELL ACTUATOR ue a 5 OVERFLOW 2 l J AIR SWITCH a POWER SUPPLY ___ _ MAX WATER LEVEL 5 GAL __ WITH TIMER JET LIGHT AIR SWITCH J 15 AMP RATED DRAIN PUMP AIR SWITCH XI JET 12 VOLT LED LIGHT TRX i XXXX e y DOOOCX FILL MIX VALVE
15. SF x 3 8 compression Flexible Tube UPC Approved Control Mixer Control Mixer Control Mixer Econo Control Mixer Single lever Clock wise i A me T4 LCM T4 CCM al NPSM Connections NPSM Connections NPSM Connections Single Lever Clockwise Econo Replacement Replacement Replacement Cartridge Cartridge Cartridge T4 LCMC T4 CCMC T4 ECMC Limited Warranty Pre Registration Required Spa1000 Pedicure spas are manufactured with the highest standards for quality and workmanship Accordingly Spa1000 warrants its products as follows To the original owner of the Spa1000 pedicure spas Spa1000 may repair or replace at its option any pedicure spa deemed to be defective in material or workmanship upon inspection by an authorized representative of Spa1000 This warranty covers only the listed components for the following time periods e Recirculating Pump One 1 year from date of shipment All other components One 1 year from date of shipment e There are no other warranties express or implied Owner must pay all labor and shipping charges necessary to replace or repair the pedicure spa Spa1000 will not be liable for any consequential incidental or contingent damages Some states do not allow the exclusion or limitation of incidental or consequential damages so the above limitation or exclusion may not apply to you If a pedicure spa needs to be exchanged it will be limited to supplying a replacement pedicure s
16. a terre En cas de d faillance ou de panne ventuelles la mise la terre fournit au courant lectrique un chemin de moindre r sistance qui r duit le danger de choc lectrique Toutes les prises connect es aux spas de p dicure doivent comprendre un disjoncteur de fuite la terre ou GFCI Ce dispositif r duira les risques de choc lectrique Ce spa est con u pour fonctionner sur une alimentation standard de 110 Volts 60 Hz Ce spa comporte un cordon d alimentation muni d un conducteur de mise la terre de l quipement et d une fiche avec broche de terre La fiche doit tre branch e dans une prise murale appropri e correctement install e et mise la terre conform ment tous les r glements et ordonnances municipaux En cas de doute quant la mise la terre ad quate de l quipement communiquer avec un lectricien ou technicien agr Une mauvaise connexion du con ducteur de mise la terre de l quipement risque de provoquer une lectrocution ou un incendie Ne modifier en aucun cas la fiche trois broches fournie avec l quipement si elle n entre pas dans la prise murale faire installer une prise appropri e par un lectricien agr MISE EN GARDE DISPOSITIF DE R INITIALISATION THERMIQUE DE PROTECTION La chaise de massage est quip e d un dispositif de r initialisation thermique de protection II s agit d une fonction de s curit qui prot ge l appareil contre la surchauffe Si la chaise s arr te so
17. age Helps relieves muscle tension improves circulation and relaxes the back 13 Installing the New Armrest Place the new controller PCB into position on the underside of the upper armrest panel then Armie replace the five screws to secure it Connect the armrest connector to the PCB connector Align the upper armrest panel tabs with the corresponding slots on the armrest then slide the upper armrest panel backward and down to secure it Fig 9 Controller label Using a Phillips head screwdriver replace the two screws on the control panel Fig 10 Apply the new controller label to the control panel Fig 11 Using a Phillips head screwdriver replace the screw on the underside of the armrest where the manicure tray was mounted Fig 12 Place the manicure tray into position then use the 5mm Allen key to re place the two Allen screws on the underside of the armrest securing the tray Fig 13 8 Using a long handled Phillips head screw driver replace the screw on the rear under side of the armrest IMPORTANT You must insert the screwdriver at an angle as shown in Fig 14 9 Using two hands snap the rear side into place Fig 15 Fig 15 Rear side panel Liner Jet and Liner Instructions ATTENTION e Do not run Liner Jet without water This will void your warranty Do not place two wet ends into same bowl when cleaning The jet s strong magnets could cause injury e D
18. annot operate efficiently or safely unless it is provided with adequate electrical power sufficient water pressure proper water temperature and required drainage capabilities Contact your local building inspector for information and local code compliance procedures that need to be followed when having your pedicure spa installed Subsequent inspections and approvals that may be required are the responsibility of the purchaser IL EST IMPORTANT DE LIRE ET DE SUIVRE ATTENTIVEMENT CES CONSIGNES DE SECURITE VEUILLEZ CONSERVER CE MANUEL DANS UN ENDROIT SUR DANGER Risque de choc lectrique Connecter seulement un circuit prot g par un disjoncteur de fuite la terre UNE MISE A LA TERRE EST INDISPENSABLE L unit doit tre install e par un technicien qualifi elle doit tre mise la terre Elle doit tre install e de mani re permettre l acc s pour l entretien ATTENTION Risque de choc lectrique D connecter l alimentation lectrique avant tout entretien MISE EN GARDE Risque de blessure ou de noyade accidentelle ne pas laisser des enfants utiliser la baignoire d hydromassage sans la surveillance d un adulte MISE EN GARDE Risque de blessure ou de noyade accidentelle pour viter le happement de membres ou de cheveux utiliser la baignoire d hydromassage uniquement lorsque les prises d aspiration sont toutes munies d une grille de protection MISE EN GARDE Pour viter les blessures user de prudence en entra
19. ble for any infections or disease that may result from improper cleaning or failure to adhere to sanitation requirements After Each Customer 1 Ensure the unit is off and clean the head one at a time 2 Use a screwdriver to remove the screw that locks the Jet head with the tub mounting housing 3 Spray Sanitex disinfectant on impeller 4 Spray Sanitex disinfectant on both sides of suction cover 5 Thoroughly clean inside surface of spa tub foot rest and arm rest with Sanitex disinfectant wipes 6 Thoroughly clean rest of the spa basin surface with Sanitex disinfectant wipes 7 Allow 10 minutes for disinfecting time to complete Remove suction cover by turning Spray impeller Spray suction cover on both sides Replace suction cover by turning Clean the rest of the spa tub footrest counter clockwise clockwise Clean inside basin with and armrest with disinfectant wipes disinfectant wipes Every Night 1 Ensure the unit is off and clean the head one at a time 2 Use a screwdriver to remove the screw that locks the Jet head with the tub mounting housing 3 Use a soft brush and water to clean suction cover 4 Use a soft brush and water to clean impeller Put suction cover back in its place by turning clockwise 5 Fill tub Add 1 level scoop of Pedi Clear disinfectant crystals or other EPA Approved cleaner follow manufacturer s instructions 6 Circulate for 10 minutes and let it soak overnight 7 The next morning drain water
20. damaged packages To register for your warranty please copy this page fill out section below attach a copy of your sales receipt and mail to us Warranty will not be honored without prior registration Some states do not allow registration to be a requisite of warranty so the above may not apply to you Company Contact Address City State Zip Telephone Email Yes Please send me updates and news on the latest Soa1000 Products and promotions PediSpa Model 222 Tub Color Sink Color Spa Serial Chair Model Chair Serial Place of Purchase Purchase Date Purchase Price Address City State Zip Telephone
21. e with these product repair instructions TOOLS REQUIRED Long handled Phillips head screwdrive Utility blade 5mm Allen key Controller Label Power off the chair then unplug it Using the utility blade peel the controller label off the left hand arm rest Fig 1 Using a Phillips head screwdriver remove the two screws located beneath the controller label Fig 2 Left hand Armrest Manicure tray Remove two Allen Screws Using a 5mm Allen key remove EA the two Allen screws located T Foy 4 5 Remove the manicure tray beneath the controller label a Fig 3 Phillips head Screw Using a Phillips head screwdriver remove the Phillips head screw located on the underneath of the armrest where the manicure tray was mounted Fig 4 Replacing the Controller PCB 7 Using two hands pull outward on the rear side panel to remove it Fig 5 Rear side panel 8 Using a long handled Phillips head screwdriver remove the screw located on the rear underside of the armrest IMPORTANT You must insert the screwdriver at an angle as shown Fig 6 Placing one hand on each end of the armrest pull the top armrest panel slightly forward and upward to detach it from the armrest and expose the PCB connector then disconnect the connector Fig 7 IMPORTANT The upper armrest is connected with a series of tabs that will break if you lift straight up on the armrest Remove the upper armrest Using a Phillips head sc
22. ecifications Massage Robot 2 Motor 4 Roller Operating Voltage AC110 120V 60Hz Power Consumption 50 Watts Size Chair reclined 45 L x 28 W x 32 H Recline Angle 165 Degrees Forward Backward 5 distance Chair Weight 80 Ibs Maximum load weight 285 lbs Number of Massage Functions Four 4 Rolling Kneading Compression Percussion Automatic Timer Shut Off 15 minutes Cover Fabric Material Polyurethane Hand held low voltage remote control for massage chair Specifications are subject to change without prior notice Basin Specifications Hot and cold water supply lines required hot and cold shut offs may be installed under or behind pedicure spa Shipping Weights Total basin see pg 7 Buffalo 213 Ib Drain installation Reference note on page 8 can be installed with optional drain pump for wall drain or a gravity Cartier 213 b ean Jet 233 Ib Vel 337 Ib Capacity of basin 4 5 U S Gallons 17 03L Traditional Whirlpool with Jets Power source 110V AC 15 Amp 60 Hz GFCI Protected Crenza 332 Ib Caution Pedicure spa must be installed by a licensed electrician and a licensed plumber conforming to all local and national electrical codes Jet System Pipe free whirlpool pedicure spas 1 jet LED lights optional drain pump Jets May contain either Geni Jet Motor 120V AC 60Hz 1 2A D 29 Jet 120V 85W 60Hz 1A Sanismart Jet 110V AC 60 Hz Liner Jet 120V 30W 60Hz Drain Pump Mo
23. g when not in use for an extended period before installation cleaning or removal of parts Keep the power cord away from heated surfaces Do not operate unit if the power cord or plug has been damaged If this unit is operating abnormally or malfunctioning immediately turn off the power and disconnect the power cord from the outlet do not operate unit if it is not working properly In the event of a power failure always turn the power switch to its OFF position When not in use always turn the power switch to its OFF position To disconnect unit turn all controls to OFF position and remove power cord from the outlet Keep all electrical devices away from this unit This unit only has a weight capacity of 300 pounds 136 06 kg Enter and exit the unit slowly and carefully Never drop or insert any object into any opening of the unit Close supervision is necessary when this unit is used by on or near children invalids and disabled persons Do not stand or allow anyone to stand in the spa basin Please be aware that a spa basin filled with water is a potential drowning hazard Check the water temperature before each use water temperature should not exceed 105 F 41 C and water temperature in heater should not exceed 150 F 65 C Disinfect the spa basin and jets after each use with an approved cleaner Do not massage any area of the body that is swollen inflamed or covered with skin eruptions
24. hydro massage bathtub equipped with heater to avoid unconsciousness and possible drowning WARNING Risk of fetal injury pregnant or possibly pregnant women should consult a physician before using a hydro massage bathtub equipped with heater WARNING Risk of hyperthermia and possible drowning do not use a hydro massage bathtub equipped with heater immediately following a strenuous exercise WARNING Risk of electric shock do not permit electric appliances such as a hair dryer lamp telephone radio or television within 1 5m 5 feet of this hydro massage bathtub CAUTION Test the ground fault circuit interrupter protecting this appliance periodically in accordance with the manufacturer s instructions WARNING Risk of hyperthermia and possible drowning water temperature in excess of 38 C 100 4 F may be injurious to your health Check and adjust water temperature before use WARNING Risk of hyperthermia people using medications and or having an adverse medical history should consult a physician before using a hydro massage bathtub equipped with heater Important Requirements All outlets connected to pedicure spas must include a GFCI device Ground Fault Circuit Interrupter This will reduce the risk of electric shock It is important that you contact a local licensed plumber and licensed electrician to install your new pedicure spa Installation must be in compliance with all your local and state building codes Your pedicure spa c
25. ing Cover the chair when not in use for a long period of time If chair will be out of use for a long period of time unplug and coil the power cord and cover the chair or place in an environment free for dust and moisture Prolonged exposure to direct sunlight can cause color fading and or damage to the massage chair Pedicure Product Guidelines Please follow these guidelines when choosing products to use in your pedicure spa Always use pedicure products and cleaning solutions in accordance with each manufacturer s directions Understand and follow your state regulations regarding proper product use and disinfecting requirements This is solely your responsibility e Avoid products that contain a foaming agent this will cause excessive foam e Products containing non dissolving abrasives such as sand and sea salts will not harm the internal component structure of your pedicure spa as long as the spa cleaning requirements are followed after each use and each night Refer to page 17 Oil based products may be used in your pedicure spa as long as the cleaning requirements are followed after each use and each night Refer to page 17 If you follow the operating cleaning and maintenance procedures this pedicure spa can give you many years of service If you experience problems with your spa please contact our Technical Support line at 1 225 236 0289 or email info spa1000 net We recommend greasing the drive shaft every 6 months
26. nt dans la baignoire d hydromassage ou en la quittant MISE EN GARDE Risque de blessure ou de noyade accidentelle afin d viter l vanouissement et le risque de noyade ne pas prendre de m dicaments ni consommer de l alcool avant ou pendant l utilisation d une baignoire d hydromassage quip e d un syst me de chauffage MISE EN GARDE Danger pour le f tus les femmes enceintes que leur grossesse soit confirm e ou non doivent consulter un m decin avant d utiliser une baignoire d hydromassage quip e d un syst me de chauffage MISE EN GARDE Risque d hyperthermie et de noyade ne pas utiliser une baignoire d hydromassage quip e d un syst me de chauffage juste apr s un exercice intense MISE EN GARDE Risque de choc lectrique ne pas placer d appareils lectriques tels qu un s che cheveux un luminaire un t l phone une radio ou un t l viseur moins de 1 5 m 5 pieds de cette baignoire d hydromassage ATTENTION V rifier r guli rement le fonctionnement du disjoncteur de fuite la terre conform ment aux instructions du fabricant MISE EN GARDE Risque d hyperthermie et de noyade une temp rature de l eau sup rieure 38 C 100 4 F peut pr senter un risque pour la sant V rifier et r gler la temp rature de l eau avant d utiliser la baignoire MISE EN GARDE Risque d hyperthermie les personnes qui prennent des m dicaments ou qui ont des probl mes de sant doivent consulter un m decin avan
27. o not attach two wet ends to each other Doing so will cause breakage to wet ends and will void the warranty The wet ends of the Liner Jet need to be taken apart and soaked each week Troubleshooting Patent Pending 2 Cradle Liner Jet wet end in your palm Do not hold Why is Liner Jet not on with your thumb Jet will attach itself to dry end Adjust to align accordingly 1 Make sure water is above the wet end 3 Fill water to 2 inches above Liner Jet wet end 2 Turn off for 3 seconds to reset the Liner Jet then turn on again 4 Press jet button Light and Liner Jet will turn on oo 3 Make sure the magnetic disk is freely rotating 4 Make sure all power connections are connected properly 5 Make sure you have 110V 120V power from your wall outlet 6 Make sure clear air tube from push button labeled Jet is con nected to the power supply black box 7 Wet end must be in place Liner Jet dry end motor will automatically turn off if wet end is not detected Why is Liner Jet making noise or vibrating The alignment is not correct Remove Liner Jet wet end and reattach Adjust to align accordingly 5 After completing pedicure dissasemble and drop wet end into concentrated disinfectant solution 6 Each day clean impeller with a soft brush 15 All brand and or product names and logos are trademarks or registered trademarks of their respective owner s Spa Basin
28. ome states do not allow limitations on how long an implied warranty lasts so the above limitations may not apply to you Should service be required for defect or malfunction during the warranty period please contact Spa1000 Customer Service 5902 Sovereign Dr Houston TX 77036 Toll Free 1 888 317 0467 Fax 225 236 0290 info spa1000 net www spa1000 net By using this pedicure spa Owner agrees that the obligation of Spa1000 shall not extend to indirect or consequential damage injury or serious bodily harm which may result from pedicure spa use Owner agrees that the obligations of Spa1000 are limited to those set herein and that there are no other obligations except those expressly agreed to in writing by Spa1000 No dealer or other person has any authority to bind Spa1000 to changes or additions to this warranty or its products accordingly Spa1000 is not responsible for any such warranties or representations Terms and Conditions All returned or exchanged items must be in new condition in their original packaging and must include all packing material blank warranty cards manuals and all accessories Defective items may at Spa1000 s option be repaired or exchanged for the same model or manufacturer s equivalent model Spa1000 is not responsible for any consequential or incidental damage resulting from use of any merchandise bought from us No refunds are given on shipping and handling charges Spa1000 is not responsible for lost or
29. pa of comparable style and size Spa1000 may at its own discretion use refurbished parts or pedicure spas for repair and replacement purposes This warranty is null and void if the pedicure spa is removed from its place of initial installation or is not installed in accordance with federal state or local codes and ordinances Furthermore this warranty does not apply if the pedicure spa has been subject to misapplication misuse improper installation or maintenance negligence improper cleaning or other circumstances beyond Spa1000 control Spa1000 Pedicure spas have a maximum weight capacity of 300 Ibs Any use exceeding this limit voids the warranty The following are examples of what is not covered by the warranty 1 Natural wear and tear 2 Staining fading or discoloration of the vinyl seat armrests or footrest 3 Damage resulting from standing in the basin 4 Damage to pump parts and or motor parts due to obstruction in plumbing lines etc 5 Staining fading or discoloration of plastic surfaces due to exposure and or the use of harmful cleaning agents or chemicals 6 Staining fading or discoloration caused by improper or poor water additives not related to maintenance of proper water 7 Malfunctions or damage caused by improper installation including not meeting local and state plumbing electrical and building codes 8 Freight damage misuse neglect abuse and natural disaster 9 Unauthorized repairs 10 Repair service S
30. please see insert provided for information related to your custom order Installation Important Installation amp Utility Information Electrical Service A 110V 60 Hz 15 Amp GFCI protected grounded circuit must be used to supply power to the pedicure spa Water Supply Observe and follow all local codes in regards to plumbing connections 30 to 80 PSI water pressure is needed to correctly fill the basin a correct level The hot water supply temperature must not exceed 150 F 65 C exceeding this tem perature may cause damage to your unit and injury If the temperature is higher than this then please lower your water heater to the correct and acceptable temperature Carefully connect the incoming water supply lines to the appropriate fittings located on the back of the pedicure spa For hot and cold water supply fittings see figure 2 below For power drain floor drain fittings location page 8 Shut off valves are recommended To prevent the water supply contamination our shower head includes a back flow preventer see figure 1 We also highly recommend you to install a Reduced Pressure Back Flow RPBP for each hot amp cold water supply line Please check with your local plumbing code requirements You are responsible for your valves connections and compliance to local codes Attach hose with red markings to hot water line Our Hot amp Cold 8 Stainless Steel Hoses are UPC Approved
31. rain pump feature open the drain by turning the overflow knob in a clockwise direction until it stops Press the silver but ton marked Drain on the front panel The water level will lower as water is pumped out of the basin Turn the pump off by pressing the Drain button on the front panel once the basin is fully drained NOTE the drain pump will automatically shut off after 2 minutes We recommend turning off the pump manually if all water has drained before automatic shut off Drain pump may overheat if operated more than 10 minutes NOTE If you are using a wall drain it is very important that you close the drain cap for each use Failure to do so will result in contamination of the system Warning It is extremely important to follow the cleaning instructions located on page 17 Failure to clean the pedicure spa adequately may result in serious health issues for your clients as well as the nail technician Failing to clean your pedicure spa may also cause the pedicure spa to not work properly Please consult your local and state codes concerning pedicure spa cleaning for further requirements Basin Cleaning Procedure Using D29 Jet WARNING Please check with your state board and city codes in your area for specific spa disinfectant procedures In addition to local requirements it is important that you carefully follow the basin cleaning procedures below to ensure that the spa is sanitized after each use Spa1000 is not lia
32. rewdriver remove the five screws that secure the PCB to the upper armrest panel Fig 8 Remove the PCB HT 1000 Massage Chair Remote Stop Stops the massage and parks the i a human touch massage rollers at the top of the brackets as J p Power Lights to indicate that master power switch is on Power Recline Effortlessly adjust the backrest to a reclined or up right position O Position up down arrows Use these buttons along with any mas sage technique to target the mas position sage to the desired area of your Forward Slides the chair foarward back You can press this button be Backward Slides the chair backwards fore or after selecting the massage technique range zone rolling Q Massage Techniques Four massage techniques let you customize your massage percussion compression kneading lower upper full o Ver yer Je programs Massage Programs massage the specific area of your back for 15 minutes using a variety of techniques The correspond ing LED lights on the remote indicate which massage mode is currently in use Full Massages your entire back Upper Massages your upper back Lower Massages your lower back 12 Massage Techniques Now choose a massage technique to suit your mood Your Human Touch massage chair lets you customize your massage using a wide variety of massage techniques Choose from three stationary mas
33. sage techniques and a rolling massage or combine them Use the Position and Zone buttons to target your massage to a specific area or select one of the three auto massage programs and let the chair take control No matter how you use it your Human Touch massage chair offers maximum massage flexibility and refreshing benefits D Alternative rapid tapping strokes along the spine to stimulate both spinal muscles and spinal joint areas emulating the percussive massage technique used in sports medicine for deep muscle therapy Flexes spinal joints and relieves pressure on the spinal column invigorating the entire back area Presses on spinal muscles and spinal joint areas using alternating strokes and a gentle rocking motion emulating a technique used in sports medicine and in spinal therapy by chiropractors Spreads and applies pressure to deep muscle tissue forcing it to relax while the rocking motion loosens spinal joints Aides in muscle and joint repair due to strain from exercise long hurs bent over a desk or just day to day stress and can improve mobility and overall posture Kneads your back in a small circular motion on both sides of your spine at the same time Relieves tension and soreness by lifting and stretching muscles Improves circula tion and helps bring vital nutrients to the spinal area Rolls gently up and down your back near your spine Warms and loosens your muscles preparing your back for deeper mass
34. t d utiliser une baignoire d hydromassage quip e d un syst me de chauffage more important safety instructions SAVE THESE INSTRUCTIONS Before using your new pedicure spa please read and observe these safety instructions carefully to reduce the possibility of injury serious bodily harm death fire and or other property damage For additional questions please call our Technical Support Department at 1 225 236 0289 WARNING It is very important that you carefully follow the basin cleaning procedures on page 17 to ensure that the spa is sanitized after each use Spa1000 is not liable for any infections or disease that may result from improper cleaning or failure to adhere to sanitation requirements This pedicure spa unit should only be operated in a room temperature between 40 F 4 C and 100 F 38 C Do not use unit outdoors or in excessively humid or dusty environments Do not use unit where aerosol spray products are being used or oxygen is being administered Do not operate unit if it has been damaged Always connect this unit to a properly grounded electrical outlet This unit is designed only to operate on a standard 110Volt 60Hz current Exceeding this standard may cause injury and or serious bodily harm and or damage to property Do not use this unit if noise above normal sound is heard To reduce the risk of burns fires and electrical shock never leave this unit unattended if plugged in and always unplu
35. tors May contain either Little Giant Model 3E 34N 115V 60 Hz 2 5A T4 DPH 120 V AC 85W 60Hz 1 A LED Lights May contain either T4 L18 Input 120V AC 60Hz 28VA Output 12V 60 Hz 1 67A T4 L18C Input 120V AC 60Hz 28 VA Output 12V Ac 1 67A 20VA Class 2 Electrical switches On Off air switch for Geni Jet amp Led Light On Off air switch for drain pump Limited warranty One 1 year from date of purchase Due to our policy of continuous improvements all specifications are subject to change without notice Note All dimensions and weights are approximate 21 Spa Jets Liner Jet Bubble Maker Dry End Wet End Drain Pump Assemblies T4 SSD Little Giant Drain Pump Assembly T4 DP Siar i Includes check valve amp P Trap 110V 2 5A Dry End includes motor and board D29 Jet 120V 85W T4 D29 Jets are angled to 29 for precise whirlpool action Transformer New Technology Works with spa liners No drilling necessary T 4 Drain Pump Assembly T4 DPH Includes check valve amp P Trap 110V 1A Check Valves Hardware Dual Check Valve 2 Check Valve se 2 Diverter Tee T4 1 2 CV T4 DT T4 DCV 1 2 compression 3 8 compression Some cities require a backflow preventer to be installed on hot cold water line CSA approved Power Supply Floor Drain Power Supply T4 3S1C T4 2S171C 2 on off 1 timer 2 minutes 1 continuous
36. u dommages corporels ou encore de s rieux dommages mat riels Ne pas utiliser ce spa s il produit un bruit sup rieur la normale Afin de r duire les risques de br lures d incendie et de choc lectrique ne jamais laisser ce spa sans surveillance s il branch sur l alimentation On doit tou jours le d brancher s il n est pas utilis pendant une longue p riode de temps avant son installation avant tout nettoyage ou avant un d montage e Maintenir le cordon d alimentation loin des surfaces chauff es Ne pas faire fonctionner le spa si le cordon d alimentation ou la fiche a t endommag Si ce spa fonctionne anormalement ou fonctionne mal couper le courant imm diatement et d brancher le cordon d alimentation de la prise murale ne pas faire fonctionner le spa s il ne fonctionne pas correctement En cas de panne lectrique placer toujours l interrupteur d alimentation sur la position ARR T OFF Lorsque le spa n est pas utilis placer toujours l interrupteur d alimentation sur la position ARR T Pour d connecter le spa placer toutes les commandes sur la position ARR T et d brancher le cordon d alimentation de la prise murale Garder tous les appareils lectriques loin du spa Ce spa a une capacit de 300 livres 136 kg seulement Les personnes trait es dans le spa doivent s y installer et le quitter lentement et prudemment Ne jamais ins rer ou laisser tomber un objet quel qu il soit
37. udainement et ne peut tre remise en marche mettre l interrupteur principal la position ARRET OFF et ne pas faire fonc tionner la chaise pendant au moins 30 minutes L omission de couper l alimentation lectrique peut causer un d marrage inattendu de la chaise pendant que dispositif refroidit Installation Licensed Installation Required Please check your local plumbing and electrical codes Installation of this Wall pedicure spa must comply with both You must hire a licensed plumber and a licensed electrician to complete the applicable connections to your pedicure spa NOTE Failure to comply with federal state or local codes will result in the warranty being null and void Parts Included 3 2 1 2 bolts F F 1 2 bolt lt 9 gt 1 Allen Wrench See above for proper dimension Location and Support The pedicure spa must be on a level location The floor structure of that location must be capable of supporting both the pedicure spa a RS and its occupant at the same time J To fully recline the pedicure chair the base of the unit must be posi tioned to a minimum of 19 from the wall ay Minimum installation dimensions L 70 x W 30 WARNING When moving or lifting pedicure spa always lift from the bottom of spa Do not lift by control mixer or chair Doing so will damage spa Incorrect Lifting Correct Lifting For installation procedures on custom spas
Download Pdf Manuals
Related Search
Related Contents
Manhattan 701402 据付工事の注意点 Mode d`emploi pour les mini spots de jardin AURORA DECKY 1 Speco Technologies CVC5845DNV surveillance camera 取扱説明書 - 日立の家電品 カタログを閲覧する Leica A60 S Manual - Leica Microsystems Manuale Utente DVR LIFE Avaya IP Phone 2004 User Guide Harmony ® - Farmaline Copyright © All rights reserved.