        DIrEcTIoNS For uSE WAVEoNE® GoLD INSTrumENTS moDE D
         Contents
1.     e Remove a WAVEONE  GOLD file when it does not easily progress  Clean and inspect the  cutting flutes  then irrigate  recapitulate with a size 010 file and re irrigate    6 4 WAVEONE  GOLD SHAPING TECHNIQUE   1  Establish straight line coronal and radicular access    2  Inthe presence of a viscous chelator  use a size 010 hand file to verify a glide path to length  In  more restrictive canals  use a size 010 hand file in any region of a canal to create a glide path    3  Expand this glide path to at least 0 15 mm using either a manual or dedicated mechanical file   such as PATHFILE or PROGLIDER    4  ALWAYS initiate the shaping procedure with the PRIMARY file  025 07 red  in the presence of  sodium hypochlorite    5  Use gentle inward pressure and let the PRIMARY file passively progress through any region of  the canal that has a confirmed glide path  After shaping 2 3 mm of any given canal  remove and  clean the PRIMARY file  then irrigate  recapitulate with a size 010 hand file and re irrigate    6  Continue with the PRIMARY file  in 2 3 passes  to pre enlarge the coronal two thirds of the canal    7  Utilize a brushing motion on the outstroke to eliminate coronal interferences or to enhance  shaping results in canals that exhibit irregular cross sections    8  In more restrictive canals  use a size 010 hand file  in the presence of viscous chelator  negotiate  to the terminus of the canal  Gently work this file until it is completely loose at length    9  Establish wor
2.   Bei einer Wiederverwendung von WAVEONE   GOLD besteht ein erh  htes Risiko von  Kreuzkontamination und Feilenbruch     AD ESCLUSIVO USO ODONTOIATRICO    B ISTRUZIONI PER L USO DEGLI STRUMENTI WAVEONE  GOLD  FILE STERILI CON MOVIMENTO ALTERNATO  RECIPROCATING MOTION    REF  A0750    Strumenti WAVEONE   GOLD per il trattamento endodontico   e SMALL WAVEONE  GOLD N  020  07    e PRIMARY WAVEONE  GOLD N  025  07  e MEDIUM WAVEONE  GOLD N  035  06  e LARGE WAVEONE   GOLD N  045  05    COMPOSIZIONE  La parte tagliente di questi strumenti    realizzata in lega di nickel titanio     1  INDICAZIONI PER L USO  Questi strumenti devono essere usati in ambiente clinico o ospedaliero  da personale qualificato  e secondo le corrette procedure odontoiatriche  con guanti  occhiali  diga di gomma         Gli strumenti WAVEONE   GOLD sono indicati per il trattamento endodontico mediante  sagomatura e pulizia del sistema canalare     2  CONTROINDICAZIONI  Come per tutti gli strumenti canalari meccanici  gli strumenti WAVEONE   GOLD non dovrebbero  essere utilizzati in caso di pronunciata curvatura apicale     3  AVVERTENZE  Il prodotto contiene nickel e non dovrebbe essere usato in caso di pazienti di cui sia nota una  sensibilit   allergica a questo metallo     4  PRECAUZIONI  e   file WAVEONE   GOLD sono monouso     e Pulire frequentemente le scanalature e controllare eventuale presenza di distorsione o usura    e Dopo la rimozione di un file WAVEONE   GOLD da un canale  irrigare abbondantem
3.   poich   questa potrebbe causare la  rottura dello strumento     6  ISTRUZIONI PASSO PASSO PER I FILE WAVEONE   GOLD   6 1 Valutazione radiografica  Rivedere diverse radiografie orizzontali angolate per determinare in modo diagnostico la  larghezza  la lunghezza e la curvatura di una data radice e di un dato canale     6 2 Preparazione dell   accesso PRECAUZIONI  Creare un accesso lineare a uno o pi   orifizi del canale  enfatizzando la svasatura  la lisciatura e  la finitura delle pareti assiali interne     6 3 Precauzioni  e Dopo la rimozione di un file WAVEONE   GOLD da un canale  irrigare abbondantemente e  frequentemente     e Far avanzare passivamente il file WAVEONE   GOLD nel canale applicando una lieve pressione e  movimenti di debole ampiezza  2   3 mm  lungo un glide path liscio e riproducibile     e Se un file WAVEONE  GOLD  non avanza facilmente  rimuoverlo  Pulire e ispezionare le  scanalature taglienti  quindi irrigare e ricapitolare con un file misura 010 e irrigare nuovamente   6 4 TECNICA DI SAGOMATURA WAVEONE  GOLD  1  Creare un accesso coronale e radicolare rettilineo     2  In presenza di un agente chelante viscoso  usare un file manuale misura 010 per verificare  la lunghezza di un glide path  In canali pi   ristretti  usare un file manuale misura 010 in una  qualsiasi zona di un canale per creare un glide path     3  Espandere il glide path fino ad almeno 0 15 mm usando un file meccanico manuale o dedicato  come  ad esempio  PATHFILE o PROGLIDER     4 
4.  Gegenwart eines viskosen  Chelators das Kanalende bearbeiten  Behutsam mit dieser Feile arbeiten  bis sie bei erreichter  L  nge absolut locker ist     9  Arbeitsl  nge bestimmen  G  ngigkeit sicherstellen und Gleitpfad   berpr  fen     10  Den Gleitpfad mit einer manuellen oder mechanischen Gleitpfadfeile auf mindestens 0 15 mm  erweitern     11  Die PRIMARY Feile in einem oder mehreren Durchg  ngen bis zur vollen Arbeitsl  nge einf  hren   Beim Erreichen der L  nge die Feile herausnehmen  um ein zu starkes Vergr    ern des Foramens  zu vermeiden  Die apikalen Bereiche des Arbeitsteils   berpr  fen  wenn sie mit Dentin bedeckt  sind  ist die Aufbereitung beendet       12  Wenn die PRIMARY Feile nicht weiter vordringt  die SMALL Feile  020 07 gelb  in einem oder  mehreren Durchg  ngen bis zur Arbeitsl  nge verwenden und dann mit der PRIMARY Feile die  Aufbereitung bis zur Arbeitsl  nge optimieren     13  Wenn die Aufbereitung beendet ist  mit 3 D Desinfektionsprotokollen fortfahren       Wenn die PRIMARY Feile bei erreichter L  nge zu locker ist und die apikalen Bereiche des  Arbeitsteils nicht mit Dentin bedeckt sind  Aufbereitung mit ein er MEDIUM Feile  035 06 gr  n  und   oder einer LARGE Feile  045 05 wein  fortsetzen  bis die apikalen Bereiche des Arbeitsteils mit  Dentin bedeckt sind     7  REINIGUNG  DESINFEKTION UND STERILISATION  WAVEONE   GOLD ist nur zum Einmalgebrauch vorgesehen     Es gibt daher keine Empfehlungen zu Reinigung  Desinfektion und Sterilisation   
5.  Iniziare SEMPRE la procedura di sagomatura con il file PRIMARY  025 07 rosso  in presenza di  ipoclorito di sodio     5  Applicare una lieve pressione per far avanzare passivamente il file PRIMARY attraverso ogni  zona del canale che presenta un glide path confermato  Dopo avere eseguito una sagomatura di  2 3 mm di ogni dato canale  rimuovere e pulire il file PRIMARY  quindi irrigare  ricapitolare con un  file manuale misura 010 e irrigare nuovamente     6  Continuare con il file PRIMARY per 2 3 passaggi per allargare preventivamente il canale coronale  a due terzi della lunghezza     7  Utilizzare un movimento spazzolante verso l esterno per eliminare interferenze coronali o per  migliorare i risultati della sagomatura nei canali che mostrano sezioni trasversali irregolari     8  In canali pi   ristretti  usare un file manuale misura 010 in presenza di un agente chelante viscoso  e negoziare fino alla fine del canale  Lavorare delicatamente con questo strumento fino a quando  non    completamente libero per tutta la sua lunghezza     9  Determinare la lunghezza di lavoro  confermare la perviet   e verificare il glide path   10  Espandere il glide path ad almeno 0 15 mm usando un file per glide path manuale o meccanico     11  Portare il file PRIMARY alla lunghezza completa di lavoro in uno o pi   passaggi  Al  raggiungimento della lunghezza  rimuovere il file per evitare un allargamento eccessivo del foro   Ispezionare le scanalature apicali  se sono piene di detriti denti
6.  blanca   hasta que se llenen las espiras apicales     7  DESINFECCI  N  LIMPIEZA Y ESTERILIZACI  N  Las limas WAVEONE  GOLD est  n dise  adas para un solo uso     No est  n recomendados los procedimientos de desinfecci  n  limpieza y esterilizaci  n   Reutilizar las limas WAVEONE  GOLD aumenta el riesgo de contaminaci  n cruzada y fractura                       Sterilized product   electromagnetic or    ionic radiation steril     ization process    rile  processus  de st  rilisation  par rayonnement    lectromagn  tique  ou ionique    Steriles Produkt      Sterilisation durch  elektromagnetische  oder ionische  Bestrahlung    zato  processo di  sterilizzazione con  radiazioni elettro   magnetiche o  ioniche    EN FR DE IT ES  Symbols Symboles Symbole Simboli Simbolos  Handle Right Manche angle A a    rd    angle RA droit AD Winkelst  ck  WS  Contrangolo Contra   ngulo  os Expiry date Date de p  remption Verfallsdatum Data di scadenza Fecha de caducidad  tael Manufacturer Fabricant Hersteller Produttore Fabricante  SE Voir mode d emploi s   dee      A See directions      Gebrauchsan  Seguire le istruzioni Ver instrucciones  et instructions      for use f weisung beachten d uso de uso  d usage  Produit st    rl Producto    est  ril  Proceso  de esterilizaci  n  mediante radiaci  n  electromagn  tica  o i  nica       Do not resterilize    Ne pas rest  riliser    Nicht re sterilisieren    Non risterilizzare    No reesterilizar       Single use only       usage unique    Nur zum 
7.  rec  proco con los motores espec  ficos de Dentsply Maillefer     e Las limas WAVEONE  GOLD se venden ya esterilizadas  por lo que no pueden volver a  esterilizarse     e WAVEONE  GOLD utiliza un m  todo exclusivo de procesamiento del alambre que aumenta  la resistencia a la fatiga c  clica en comparaci  n con los alambres de NiTi convencionales   Debido a ello  es posible que el aspecto de las limas WAVEONE  GOLD sea algo curvado   No se trata de un defecto de fabricaci  n y no es necesario enderezar la lima para utilizarla   Una vez introducida en el canal  la lima WAVEONE  GOLD seguir   la v  a de deslizamiento  adapt  ndose a las curvaturas naturales     5  REACCIONES ADVERSAS  Al igual que todos los sistemas rotatorios para la preparaci  n de conductos radiculares  los  instrumentos WAVEONE  GOLD no deben usarse en aquellos casos que presenten curvaturas  apicales pronunciadas y bruscas debido al elevado riesgo de fractura     6  INSTRUCCIONES PASO A PASO DE LAS LIMAS WAVEONE  GOLD   6 1 Evaluaci  n radiogr  fica  Obtener radiograf  as tomadas desde diferentes   ngulos del plano horizontal para determinar la  anchura  longitud y curvatura del canal o ra  z en cuesti  n     6 2 Preparaci  n de acceso  Crear un acceso en l  nea recta al orificio de entrada del conducto  teniendo presente la  conicidad  la planicidad y el acabado de las paredes axiales internas     6 3 Precauciones  e Irrigar con frecuencia y en abundancia tras retirar de un canal cualquier lima WAVEONE  G
8. ARGE WAVEONE  GOLD file No 045  05    COMPOSITION  The cutting part of these instruments is made of nickel titanium alloy     1  INDICATIONS FOR USE  These instruments are to be used only in a clinical or hospital environment  by qualified users   following good dental practices  using gloves  glasses  rubber dam          WAVEONE  GOLD instruments are for use in endodontic treatment  by shaping  amp  cleaning the  root canal system     2  CONTRAINDICATIONS  In common with all mechanically driven root canal instruments  WAVEONE  GOLD instruments  should not be used in cases of severe and sudden apical curvatures     3  WARNINGS  This product contains nickel and should not be used for individuals with known allergic sensitivity  to this metal     4  PRECAUTIONS  e The WAVEONE  GOLD files are single use instruments     e Clean flutes frequently and check for signs of distortion or wear    e Irrigate abundantly and frequently after removing any given WAVEONE  GOLD file from a  canal    e Always initiate the shaping procedure with the PRIMARY WAVEONE  GOLD file in the  presence of sodium hypochlorite    e Use a gentle inward pecking motion  with short 2 3 mm amplitude strokes  to passively  advance the WAVEONE  GOLD file along a smooth  reproducible glide path     WAVEONE GOLD_0115_DFU_EN FR DE ES IT indd 1    e Remove a WAVEONE  GOLD file when it does not easily progress  Clean and inspect the  cutting flutes  then irrigate  recapitulate with a size 010 file and re irrigate    e 
9. Einmalge   brauch    Monouso    Un s  lo uso       Batch number    N   de lot    Chargenbezeich     Numero di lotto    N  mero de lote                nung  R  f  rence Riferimento com  N  mero de  Reference number    Referenznummer   j  commerciale merciale Referencia  Assortment Assortiment Sortiment Assortimento Surtido  Nickel titanium NiTi Nickel Titan Nickel titanio N  quel Titanio  Silicone Silicone Silikon Silicone Silicona       Do not use if seal  broken    Ne pas utiliser si le  sceau est bris      Nicht verwenden   wenn Siegel  gebrochen    Non usare in caso di  sigillo rotto    No usar el producto  si el sellado est    roto       Non sterilizable    Non st  rilisable    Nicht sterilisierbar    Non sterilizzabile    No esterilizable       Opened packages  are not replaced    Emballage ouvert   non remplac      Ge  ffnete Verpack   ung  nicht ersetzbar    Le confezioni aperte  non sono sostituibili    Los embalajes  abiertos no se  cambian             Can not be sold  separately       Vente s  par  e  non  autoris  e       Wird nicht einzeln  verkauft       Non pu   essere  venduto separata   mente       No puede ser  vendido separada   mente          Manufacturer   Fabricant   Hersteller   Fabbricante   Fabricante          Maillefer Instruments Holding S  rl  Chemin du Verger  3   CH 1338 Ballaigues   Switzerland    DENSPLY    FISDR   F1902140 X   01   2014 updated 01 2015    16 01 2015 18 16 18    
10. Feile herausnehmen  wenn sie nicht mehr m  helos vordringt   Die Schneidekanten reinigen und pr  fen  dann sp  len und mit einer Feile der Gr    e 010  wiederholen und erneut sp  len             16 01 2015 18 16 16    6 4 AUFBEREITUNG MIT WAVEONE  GOLD   1  Von koronal und radikular einen geradlinigen Zugang praparieren    2  Mit einer Handfeile der Gr    e 010 in Gegenwart eines viskosen Chelators den Gleitpfad bis  zur L  nge pr  fen  Bei eingeschr  nkteren Kan  len mit einer Handfeile der Gr    e 010 in einem  beliebigen Bereich des Kanals einen Gleitpfad schaffen    3  Mit einer manuellen oder einer speziellen mechanischen Feile  wie PATHFILE oder PROGLIDER   diesen Gleitpfad auf mindestens 0 15 mm erweitern    4  Die Aufbereitung IMMER mit der PRIMARY Feile  025 07 rot  in Gegenwart von  Natriumhypochlorit beginnen    5  Mit leichtem Druck nach innen die PRIMARY Feile passiv durch alle Bereiche des Kanals mit  best  tigtem Gleitpfad vordringen lassen  Nach der Aufbereitung von 2 3 mm eines Kanals die  PRIMARY Feile herausnehmen und reinigen  dann sp  len und mit einer Handfeile Gr    e 010  widerholen und erneut sp  len    6  Weiter mit der PRIMARY Feile in 2 3 Durchg  ngen die beiden koronalen Kanaldrittel vor   erweitern    7  Durch ausw  rtsgerichtete B  rstbewegung koronale Interferenzen beseitigen oder das Ergebnis  der Aufbereitung bei Kan  len mit unregelm    igen Querschnitten verbessern     8  Bei eingeschrankteren Kan  len mit einer Handfeile der Gr    e 010 in
11. OLD     e Realizar un movimiento de picoteo suave hacia dentro  con avances de 2 3 mm de  profundidad  para avanzar pasivamente con la lima WAVEONE  GOLD a lo largo de una v  a  de deslizamiento suave y reproducible    e Retirar la lima WAVEONE  GOLD si no avanza con facilidad  Limpiar e inspeccionar las  espiras cortantes  irrigar  recapitular con una lima del calibre 10 y volver a irrigar     6 4 T  CNICA DE CONFORMACI  N CON WAVEONE  GOLD  1  Establecer un acceso coronal y radicular en l  nea recta     2  Aplicar gel quelante y utilizar una lima manual del calibre 10 para verificar la v  a de deslizamiento  hasta la longitud apropiada  En canales m  s restringidos  utilizar una lima manual del calibre 10  en cualquier regi  n del canal para crear la v  a de deslizamiento     3  Expandir dicha v  a hasta al menos 0 15 mm utilizando una lima manual o mec  nica espec  fica  como PATHFILE o PROGLIDER     4  Iniciar SIEMPRE el proceso de conformaci  n con la lima PRIMARY WAVEONE  GOLD  025 07  roja  aplicando hipoclorito s  dico  NaClO     5  Aplicar una leve presi  n hacia dentro y hacer avanzar la lima PRIMARY pasivamente por  cualquier zona del canal donde se haya verificado una v  a de deslizamiento  Tras haber  conformado 2 3 mm del canal  retirar y limpiar la lima PRIMARY  irrigar  recapitular con una lima  del calibre 10 y volver a irrigar     6  Continuar con la lima PRIMARY y hacer 2 o 3 pasadas para llevar a cabo un ensanchamiento  previo de los dos tercios coronales 
12. PRIMARY sur toute la longueur de  travail pour optimiser la forme    13  Une fois la forme termin  e  poursuivre avec les protocoles de d  sinfection 3 D       Si la lime PRIMARY est d  gag  e sur toute la longueur  sans d  bris dentinaires dans les spires  apicales  continuer la mise en forme avec la lime MEDIUM  035 06 verte  et ou la lime LARGE   045 05 blanche  jusqu      ce que les spires apicales soient charg  es     7  D  SINFECTION  NETTOYAGE ET ST  RILISATION  WAVEONE   GOLD est pr  vue pour un usage unique   Les proc  dures de d  sinfection  nettoyage et st  rilisation ne sont pas recommand  es   R  utiliser une lime WAVEONE   GOLD peut accro  tre le risque de contamination crois  e et de  rupture     NUR F  R DEN ZAHN  RZTLICHEN GEBRAUCH    CI GEBRAUCHSANWEISUNG F  R WAVEONE  GOLD INSTRUMENTE  STERILE WURZELKANALFEILEN F  R ALTERNIERENDE ROTATION   REF  A0750    WAVEONE  GOLD Instrumente f  r endodontische Behandlungen   e SMALL WAVEONE   GOLD Feile Nr  020  07  e PRIMARY WAVEONE   GOLD Feile Nr  025  07  e MEDIUM WAVEONE   GOLD Feile Nr  035  06  e LARGE WAVEONE   GOLD Feile Nr  045  05    ZUSAMMENSETZUNG  Das Arbeitsteil dieser Instrumente besteht aus einer Nickel Titan Legierung     1  INDIKATIONEN  Diese Instrumente d  rfen nur von qualifizierten Personen in Zahnarztpraxen und Krankenh  usern  gem     guter zahn  rztlicher Praxis  Schutzhandschuhe  Schutzbrille  Kofferdam       verwendet  werden   Die WAVEONE   GOLD Instrumente sind f  r endodontische Behandlun
13. SITION  La partie tranchante de ces instruments est en alliage nickel titane     1  INDICATIONS D UTILISATION  Ces instruments sont destin  s    une utilisation en milieu m  dical ou hospitalier uniquement  par  des utilisateurs qualifi  s  respectant les bonnes pratiques de dentisterie  port de gants  lunettes   digue               Les instruments WAVEONE  GOLD sont utilis  s en traitement endodontique pour la mise en  forme et le nettoyage du syst  me canalaire     2  CONTRE INDICATIONS  Comme tous les instruments de traitement canalaire m  canis  s  les instruments WAVEONE S  GOLD ne doivent pas   tre utilis  s en cas de courbure apicale brusque et s  vere     3  MISES EN GARDE  Ce produit contient du nickel et ne doit pas   tre utilis   pour les individus pr  sentant une  sensibilit   allergique connue    ce m  tal     4  PR  CAUTIONS    e Les limes WAVEONE  GOLD sont des instruments    usage unique    e Nettoyer souvent les spires et v  rifier tout signe de d  formation ou d usure    e  Irriguer abondamment et fr  quemment apr  s le retrait de toute lime WAVEONE   GOLD d un  canal    e Toujours commencer la proc  dure de mise en forme avec la lime PRIMARY WAVEONE    GOLD en pr  sence d hypochlorite de sodium    e Effectuer un l  ger mouvement de va et vient de faible amplitude  2    3 mm  afin de permettre  une p  n  tration passive de la lime WAVEONE   GOLD le long d un couloir d irrigation r  gulier  et reproductible    e Lorsqu une lime WAVEONE   GOLD ne progresse plu
14. These files are driven in precise forward reverse reciprocating angles and must be used in  reciprocating motion with dedicated Dentsply Maillefer motors    e WAVEONE  GOLD files are sold sterile and are non autoclavable    e WAVEONE  GOLD uses a unique approach in wire processing that increases the resistance  to cyclic fatigue compared to standard NiTi  Due to this processing  WAVEONE   GOLD files  may appear slightly curved  This is not a manufacturing defect  It is not necessary to straighten  the file prior to use  Once inside the canal  the WAVEONE  GOLD file will follow the glide path   conforming to natural curvatures     5  ADVERSE REACTIONS  In common with all mechanically driven root canal instruments  WAVEONE  GOLD files should  not be used in cases of severe and sudden apical curvature due to high risk of breakage     6  STEP BY STEP INSTRUCTIONS FOR WAVEONE  GOLD FILES  6 1 Radiographic Evaluation  Review different horizontally angulated radiographs to diagnostically determine the width  length   and curvature of any given root and canal   6 2 Access Preparation  Create straight line access to the canal orifice s  with emphasis on flaring  flattening  and finishing  the internal axial walls   6 3 Precautions  e Irrigate abundantly and frequently after removing any given WAVEONE  GOLD file from a  canal    e Use a gentle inward pecking motion  with short 2 3 mm amplitude strokes  to passively  advance the WAVEONE  GOLD file along a smooth  reproducible glide path
15. aplanir et  appr  ter les parois axiales internes    6 3 Pr  cautions   e   rriguer abondamment et fr  quemment apr  s le retrait de toute lime WAVEONE   GOLD d un  canal    e Effectuer un l  ger mouvement de va et vient de faible amplitude  2    3 mm  afin de permettre  une p  n  tration passive de la lime WAVEONE   GOLD le long d un couloir d irrigation r  gulier  et reproductible    e Lorsqu une lime WAVEONE   GOLD ne progresse plus facilement  l enlever  Nettoyer et v  rifier  les ar  tes de coupe  puis irriguer  r  p  ter avec une lime de taille 010 et irriguer    nouveau     6 4 TECHNIQUE DE MISE EN FORME WAVEONE  GOLD   1  Etablir un acc  s coronaire et radiculaire direct    2  En pr  sence d un ch  lateur visqueux  utiliser une lime manuelle de taille 010 pour v  rifier le  couloir d irrigation sur toute sa longueur  Dans des canaux plus   troits  utiliser une lime manuelle  de taille 010 dans toute zone du canal pour cr  er un couloir d irrigation    3  Agrandir ce couloir d irrigation    une dimension minimale de 0 15 mm    l   aide d une lime  manuelle ou d une lime m  canique sp  ciale  telle qu   une PATHFILE ou une PROGLIDER    4  TOUJOURS commencer la proc  dure de mise en forme avec la lime PRIMARY  025 07 rouge   en pr  sence d hypochlorite de sodium    5  Appliquer une l  g  re pression p  n  trante et laisser la lime PRIMARY progresser de mani  re  passive    travers toute zone du canal travers  e par un couloir d irrigation pr  par    Apr  s la mise  en fo
16. del canal     7  Efectuar un movimiento de cepillado hacia el exterior para eliminar interferencias coronales o  para mejorar los resultados de conformaci  n en canales que presenten secciones transversales  irregulares    8  En canales m  s restringidos  utilizar una lima manual del calibre 10 y aplicar gel quelante  para continuar hasta el t  rmino del canal  Utilizar esta lima con suavidad hasta que quede  completamente suelta en toda su longitud    9  Establecer la longitud de trabajo  confirmar la permeabilidad apical y verificar la v  a de  deslizamiento     10  Expandir dicha v  a hasta al menos 0 15 mm utilizando una lima de permeabilidad manual o    mec  nica     11  Hacer avanzar la lima PRIMARY hasta la longitud de trabajo completa en una o m  s pasadas   Al alcanzar dicha longitud  retirar la lima para evitar agrandar el orificio en exceso  Inspeccionar  las espiras apicales  si est  n llenas de restos de dentina  significa que la conformaci  n est      acabada      12  Si la lima PRIMARY no avanza  utilizar la lima SMALL  020 07 amarilla  en una o m  s pasadas  hasta la longitud de trabajo y  a continuaci  n  utilizar la lima PRIMARY hasta la longitud de  trabajo para optimizar la forma     13  Una vez confirmada la forma  proceder con los protocolos de desinfecci  n y sellado 3D       Si la lima PRIMARY est   suelta a la longitud dada y no hay restos de dentina en las espiras  apicales  continuar la conformaci  n con la lima MEDIUM  035 06 verde  o LARGE  045 05
17. ente e  frequentemente    e Iniziare sempre la procedura di sagomatura con il file PRIMARY WAVEONE   GOLD in  presenza di ipoclorito di sodio    e Far avanzare passivamente il file WAVEONE   GOLD nel canale applicando una lieve pressione e  movimenti di debole ampiezza  2   3 mm  lungo un glide path liscio e riproducibile     WAVEONE GOLD_0115_DFU_EN FR DE ES IT indd 2    e Se un file WAVEONE  GOLD  non avanza facilmente  rimuoverlo  Pulire e ispezionare le  scanalature taglienti  quindi irrigare e ricapitolare con un file misura 010 e irrigare nuovamente    e Questi strumenti vengono guidati con precisi angoli di incidenza inversione alternati e devono  essere usati in un movimento alternato con motori dedicati Dentsply Maillefer    e   file WAVEONE   GOLD vengono venduti gi   sterilizzati e non possono essere inseriti in  autoclave    e WAVEONE   GOLD utilizza un approccio unico per la lavorazione dei fili che aumenta la  resistenza all affaticamento ciclico rispetto agli strumenti NiTi standard  Grazie a questa  lavorazione  i file WAVEONE   GOLD possono apparire leggermente curvi  Questo non    un  difetto di fabbricazione  Non    necessario raddrizzare lo strumento prima dell uso  Una volta  inserito nel canale  il file WAVEONE   GOLD seguir   il glide path  conformandosi alle curvature  naturali     5  REAZIONI AVVERSE  Come per tutti gli strumenti canalari meccanici  gli strumenti WAVEONE   GOLD non dovrebbero  essere utilizzati in caso di pronunciata curvatura apicale
18. gen vorgesehen  d  h  f  r  die Aufbereitung und Reinigung von Wurzelkanalsystemen     2  KONTRAINDIKATIONEN  Wie alle maschinell betriebenen Wurzelkanalinstrumente sollten die WAVEONE   GOLD  Instrumente nicht in Kan  len mit starken und abrupten apikalen Kr  mmungen verwendet werden     3  WARNHINWEISE  Dieses Produkt enth  lt Nickel und sollte nicht bei Personen mit bekannter Nickelallergie  angewandt werden     4  VORSICHTSMASSNAHMEN   e Die WAVEONE   GOLD Feilen sind nur zum Einmalgebrauch vorgesehen   e    e Arbeitsteil h  ufig reinigen und auf Anzeichen von Verformung oder Abnutzung pr  fen    e Nach der Entfernung einer WAVEONE   GOLD Feile aus einem Wurzelkanal reichlich und  h  ufig sp  len    e Die Aufbereitung immer mit der PRIMARY WAVEONE   GOLD Feile in Gegenwart von  Natriumhypochlorit beginnen    e Die WAVEONE   GOLD Feile mittels vorsichtiger  2 3 mm kurzer Einw  rts Ausw  rts   Bewegungen passiv auf einem gleichm    igen  wiederholbaren Gleitpfad einf  hren    e Die WAVEONE   GOLD Feile herausnehmen  wenn sie nicht mehr m  helos vordringt    Die Schneidekanten reinigen und pr  fen  dann sp  len und mit einer Feile der Gr    e 010  wiederholen und erneut sp  len    e Diese Feilen werden in pr  zisen vorw  rts und r  ckw  rts alternierenden Winkeln angetrieben  und d  rfen nur in alternierender Rotation mit geeigneten Motoren von Dentsply Maillefer  betrieben werden    e WAVEONE   GOLD Feilen werden steril und nicht autoklavierbar verkauft    e WAVEONE   GOLD 
19. king length  confirm patency and verify the glide path    10  Expand this glide path to at least 0 15 mm using a manual or mechanical glide path file    11  Carry the PRIMARY file to the full working length in one or more passes  Upon reaching length   remove the file to avoid over enlarging the foramen  Inspect the apical flutes  if they are loaded  with dentinal debris  then the shape is finished      12  If the PRIMARY doesn t progress then use the SMALL file  020 07 yellow  in one or more passes  to working length and then use the PRIMARY file to working length to optimize the shape   13  When the shape is confirmed  proceed with 3 D disinfection protocols            If the PRIMARY file is loose at length with no dentinal debris in the apical flutes  continue shaping  with MEDIUM file  035 06 green  and or LARGE file  045 05 white  until the apical flutes are loaded     7  DISINFECTION  CLEANING AND STERILIZATION  WAVEONE   GOLD is intended for single use only     Disinfection  cleaning and sterilization procedures are not recommended   Re use of WAVEONE   GOLD can increase the risk of cross contamination and breakage     R  SERV      L USAGE DENTAIRE    GR MODE D EMPLOI INSTRUMENTS WAVEONE  GOLD  LIMES    ROTATION ALTERN  E ST  RILES   REF  A0750    Instruments WAVEONE  GOLD pour traitement endodontique   e Lime SMALL WAVEONE  GOLD No 020  07    e Lime PRIMARY WAVEONE  GOLD No 025  07  e Lime MEDIUM WAVEONE  GOLD No 035  06  e Lime LARGE WAVEONE  GOLD No 045  05    COMPO
20. les  cualificados y observando las buenas pr  cticas dentales  usando guantes  gafas  dique de goma   etc     Los instrumentos WAVEONE  GOLD se utilizan en el tratamiento endod  ncico para la limpieza y  conformaci  n de los conductos radiculares     2  CONTRAINDICACIONES    Al igual que todos los sistemas rotatorios para la preparaci  n de conductos radiculares  los  instrumentos WAVEONE  GOLD no deben utilizarse en aquellos casos que presenten curvaturas  apicales pronunciadas y bruscas     3  ADVERTENCIAS  Este producto contiene n  quel y no debe ser usado en personas con alergia conocida a este  metal     4  PRECAUCIONES  e Las limas WAVEONE  GOLD son instrumentos de un solo uso     e Limpiar las espiras con frecuencia y observar si aparecen signos de alteraci  n o desgaste   e Irrigar con frecuencia y en abundancia tras retirar de un canal cualquier lima WAVEONE  GOLD     e Iniciar siempre el proceso de conformaci  n con la lima PRIMARY WAVEONE  GOLD  aplicando hipoclorito s  dico     e Realizar un movimiento de picoteo suave hacia dentro  con avances de 2 3 mm de  profundidad  para avanzar pasivamente con la lima WAVEONE  GOLD a lo largo de una v  a  de deslizamiento suave y reproducible     e Retirar la lima WAVEONE  GOLD si no avanza con facilidad  Limpiar e inspeccionar las  espiras cortantes  irrigar  recapitular con una lima del calibre 10 y volver a irrigar     e Estas limas se manejan en   ngulos rec  procos de avance y retroceso y deben utilizarse en  movimiento
21. n  ik    SV   Aav    ikn   DA   EAnvik    EL  MoAwvikh  PL   Afouovioc  LT   Aetov  a    LV  Kai  Ec6ov  as  ET      Ta instrukcja obs  ugi jest r  wniezdostepna  na zam  wienie  w nast  puj  cych wersjach j  zykowych  Portugalski  PT    Holenderski  NL   Fi  ski  Fl   Szwedzki  SV   Du  ski  DA   Grecki  EL   Polski  PL   Litewski  LT     otewski  LV     Esto  ski   ET      0 0    m     5     ES  5       Si instrukcij   vadov   pagal u  klaus a galima gauti ir   iomis kalbomis  Portugal    PT   Oland    NL   Suomi    EI    ved     SV   Dan    DA   Graik    EL   Lenkijos  PL   Lietuviuk  LT   Latviuk  LV  ir Estuk  ET      0 0    Gei    Lietuviy       O         rokasgr  mata p  c piepras  juma ir pieejama ar       d  s valod  s  Portug  lu  PT   Holandie  u  NL   Somu  Fl   Zviedru  SV    D    u  DA   Grie  u  EL   Po  u  PL   Lietuvie  u valod  s  LT   Latvie  u  LV  un Igau  u  ET             atvie  u       0    See juhend juhend on saadaval ka taotluse korral j  rgmistes keeltes  Portugali  PT   Hollandi  NL   Soome  FI   Rootsi  SV      Eesti Taani  DA   Kreeka  EL   Poola  PL   Leedu  LT   L  ti  LV  ja Eesti  ET                  l   Visit our website  www dentsplymaillefer com    FOR DENTAL USE ONLY    CG  DIRECTIONS FOR USE WAVEONE  GOLD INSTRUMENTS  STERILE RECIPROCATING FILES   REF  A0750    WAVEONE  GOLD instruments for endodontic treatment   e SMALL WAVEONE  GOLD file No 020  07    e PRIMARY WAVEONE  GOLD file No 025  07  e MEDIUM WAVEONE  GOLD file No 035  06  e L
22. nali  la sagomatura    terminata        12  Se lo strumento PRIMARY non avanza  usare il file SMALL  020 07 giallo  in uno o pi   passaggi  alla lunghezza di lavoro  quindi usare il file PRIMARY alla lunghezza di lavoro per ottimizzare la  sagomatura     13  Quando la sagomatura    confermata  procedere con i protocolli di disinfezione tridimensionale       Se lo strumento PRIMARY    libero per la sua lunghezza e non presenta detriti dentinali nelle  scanalature apicali  continuare la sagomatura con il file MEDIUM  035 06 verde  e o LARGE  045 05  bianco  fino a quando le scanalature apicali non sono piene     7  DISINFEZIONE  PULIZIA E STERILIZZAZIONE  Gli strumenti WAVEONE   GOLD sono esclusivamente monouso     Non disinfettare  pulire e sterilizzare gli strumenti     II riutilizzo di uno strumento WAVEONE   GOLD pu   aumentare il rischio di contaminazione  incrociata e di rottura     SOLO PARA USO DENTAL       INSTRUCCIONES DE USO DE LOS INSTRUMENTOS WAVEONE  GOLD  LIMAS PARA MOVIMIENTO REC  PROCO ESTERILIZADAS   REF  A0750    Instrumentos WAVEONE  GOLD para tratamiento endod  ncico   e Lima SMALL WAVEONE  GOLD N   020  07    e Lima PRIMARY WAVEONE  GOLD N   025  07  e Lima MEDIUM WAVEONE  GOLD N   035  06  e Lima LARGE WAVEONE  GOLD N   045  05          COMPOSICI  N  La parte cortante de estos instrumentos est   fabricada con una aleaci  n de n  quel titanio     1  INDICACIONES DE USO  Estos instrumentos solo se deben usar en cl  nicas u hospitales por parte de profesiona
23. nutzt eine einmalige Drahtverarbeitungsmethode  welche den Widerstand  gegen zyklische Erm  dung im Vergleich zu herk  mmlichem NiTi verbessert  Durch diese  Verarbeitung k  nnen WAVEONE   GOLD Feilen leicht gebogen erscheinen  Dabei handelt es  sich nicht um einen Herstellungsfehler  Es ist nicht erforderlich  die Feile vor dem Gebrauch zu  begradigen  Sobald sich die WAVEONE   GOLD Feile im Wurzelkanal befindet  wird sie dem  Gleitpfad gem     den nat  rlichen Kr  mmungen folgen     5  UNERW  NSCHTE WIRKUNGEN  Wie alle maschinell betriebenen Wurzelkanalinstrumente sollten die WAVEONE   GOLD Feilen  nicht in Kan  len mit starker und abrupter apikaler Kr  mmung verwendet werden  da sonst hohe  Bruchgefahr besteht     6  ANWENDUNG DER WAVEONE   GOLD FEILEN SCHRITT F  R SCHRITT  6 1 R  ntgenologische Untersuchung  Zur diagnostischen Bestimmung von Weite  L  nge und Kr  mmung von Wurzel und Kanal  R  ntgenbilder aus verschiedenen Horizontalwinkeln konsultieren   6 2 Pr  paration der Zugangskavit  t  Geradlinigen Zugang zum Kanaleingang  zu den Kanaleing  ngen  schaffen  mit besonderem  Augenmerk auf Erweiterung  Gl  ttung und Feinbearbeitung der axialen Innenw  nde   6 3 Vorsichtsmassnahmen  e Nach der Entfernung einer WAVEONE   GOLD Feile aus einem Wurzelkanal reichlich und  h  ufig sp  len   e Die WAVEONE   GOLD Feile mittels vorsichtiger  2 3 mm kurzer Einw  rts Ausw  rts   Bewegungen passiv auf einem gleichm    igen  wiederholbaren Gleitpfad einf  hren   e Die WAVEONE  GOLD 
24. rme de 2    3 mm de tout canal  retirer et nettoyer la lime PRIMARY  puis irriguer  r  p  ter  avec une lime manuelle de taille 010 et irriguer    nouveau    6  Continuer avec la lime PRIMARY  en 2 ou 3 passes  pour obtenir un agrandissement pr  alable  des deux tiers coronaires du canal    7  Effectuer un mouvement de brossage lors de la sortie pour   liminer les interf  rences coronaires  ou pour am  liorer les r  sultats de la mise en forme dans les canaux dont la section est  irr  guli  re    8  Dans les canaux plus   troits  utiliser une lime manuelle de taille 010  en pr  sence de ch  lateur  visqueux  pour atteindre l extr  mit   du canal  Proc  der d  licatement jusqu      ce que la lime soit  compl  tement d  gag  e sur toute la longueur    9  D  terminer la longueur de travail  confirmer la perm  abilit   et v  rifier le couloir d irrigation    10  Agrandir ce couloir d irrigation    une dimension minimale de 0 15 mm    l aide d une lime  manuelle ou d une lime m  canique pour couloir d irrigation    11  Passer la lime PRIMARY sur toute la longueur de travail en une ou plusieurs passes  Une fois  la longueur atteinte  enlever la lime pour   viter un agrandissement exc  dentaire du foramen   V  rifier les spires apicales   si elles sont charg  es de d  bris dentinaires  la mise en forme est  termin  e      12  Si la lime PRIMARY ne progresse pas  utiliser la lime SMALL  020 07 jaune  en une ou plusieurs  passes sur toute la longueur de travail  puis utiliser la lime 
25. s facilement  l enlever  Nettoyer et v  rifier  les ar  tes de coupe  puis irriguer  r  p  ter avec une lime de taille 010 et irriguer    nouveau    e Ces limes sont entra  n  es selon des angles de va et vient altern  s pr  cis et sont r  serv  es     une utilisation en mouvement altern   avec des moteurs sp  ciaux Dentsply Maillefer    e Les limes WAVEONE   GOLD sont vendues st  riles et ne sont pas autoclavables     e WAVEONE   GOLD utilise une approche unique du traitement des fils qui offre une meilleure  r  sistance    la fatigue cyclique que le NiTi standard  Gr  ce    ce traitement  les limes  WAVEONE  GOLD peuvent pr  senter une l  g  re courbure  Cela n est pas un d  faut de  fabrication  Il n est pas n  cessaire de redresser la lime avant son utilisation  Une fois dans le  canal  la lime WAVEONE   GOLD suit le couloir d irrigation et ses courbures naturelles     5  EFFETS IND  SIRABLES  Comme tous les instruments de traitement canalaire m  canis  s  les instruments WAVEONE    GOLD ne doivent pas   tre utilis  s en cas de courbure apicale brusque et s  v  re en raison du  risque   lev   de rupture     6  INSTRUCTIONS PAS    PAS POUR LES LIMES WAVEONE  GOLD   6 1 Examen radiographique  Etudier les radiographies r  alis  es selon diff  rents angles horizontaux pour d  terminer la largeur   la longueur et la courbure de la racine et du canal    6 2 Pr  paration de l acc  s  Cr  er un acc  s direct aux orifices canalaires en veillant tout particuli  rement      largir  
26. wave s    one  GOLD    Directions for use  Sterile Reciprocating Files  Ref  A0750    DeNsPLY    MAILLEFER    wave  one    GOLD       Este manual de utiliza    o est   tamb  m dispon  vel  quando requisitado  nas seguintes l  nguas  Portugu  s  PT   Holand  s   NL   Finland  s  FI   Sueco  SV   Dinamarqu  s  DA   Grego  EL   Polacos  PL   Litu  nia  LT   Let  nia  LV  e Est  nia  ET      0     D  o  be    gt   Q   lt   CD  nm        O  Deze gebruiksaanwijzing is  op aanvraag  eveneens verkrijgbaar in de volgende talen  Portugees  PT   Nederlands  NL    Fins  Fl   Zweeds  SV   Deens  DA   Grieks  EL   Pools  PL   Litouws  LT   Lets  LV  en Ests  ET         8    K  ytt  ohje on saatavana my  s seuraavilla kielill    Portugali  PT      Suomi Hollanti  NL   Suomi  FI   Ruotsi  SV   Tanska  DA   Kreikka  EL   Puola  PL   Liettuan  LT   Latvian  LV  ja Viron  ET         d    Denna bruksanvisning finns   ven att tillg   p   f  ljande spr  k  Portugisiska  PT   Holl  ndska  NL   Finska  FI   Svenska  SV    Danska  DA   Grekiska  EL   Polska  PL   Litauiska  LT   Lettiska  LV  och Estniska  ET      Ka   lt   br  3  Mm  A  Di       Denne brugsanvisning kan ogs   rekvireres p   f  lgende sprog  Portugisisk  PT   Hollandsk  NL   Finsk  EI  Svensk  SV    Dansk  DA   Gr  sk  EL   Polsk  PL   Litauiske  LT   Lettiske  LV  og Estiske  ET         Aum n o  ny  a huot err  cns draB  c un  Kat  Tiv GimmOn  oTi ak    ou  e   yAwooe    Moproyad  tikn  PT   OMav  ik    NL    Hidavd  Zixn  Fl     ou
    