Home
SR 200 APR Full-face Mask
Contents
1. SR 200 APR Full face Mask Chemical Cartridge Application PAPR Application User s Instruction Manuel de l utilisation Instrucciones de uso Sundstrom Safety Inc 20 North Blossom St East Providence RI 02914 Office 1 401 434 7300 Toll Free 1 877 SUNDSTROM Fax 1 401 434 8300 info srsafety com www srsafety com English Fran ais Espanol Please read and save these instructions 3 11145 30005 essen 28 Pri re de lire et de conserver 11 A 28 Lea y conserve estas instrucciones por favor 19 lllustraciones 28 Full face Air Purifying Respirator SR 200 Table of contents 1 NIOSH Approval Limitations ll General Respirator Use Limitations lll Introduction IV Configuration and selection guide V User Training and Instructions 1 Changing the Protective Elements 2 Inspection Prior to Use 3 Donning Fit Check Doffing VI Cleaning and Storage VII Spare parts VIII Warranty IX Illustrations X NIOSH DHHS Labels Separate insert pages included with this booklet I NIOSH Approval Limitations Note All cautions and limitations do not apply to all applications Refer to the NIOSH matrix approval label insert add part num ber to verify the applicable cautions and limitations Chemical cartridge APR application A Not for use in atmospheres containing less than 19 5 percent oxygen B Not for use in atmospheres immediately dange
2. 1 WHY USE RESPIRATORY PROTECTION A Why is breathing protection necessary Breathing protection is necessary whenever you are in an atmosphere that could injure your health Depending on the substance present in the contami nated atmosphere you could be at risk of LUNG DAMAGE Bronchitis edema pneumonia DAMAGE TO VITAL ORGANS Kidneys liver brain CANCER PERMANENT DISABILITY asthma silicosis asbestosis or emphysema or at worst DEATH WARNING Do not enter a hazardous or unknown at mosphere without asking your safety profes sional what type of protection is required Use all the protective equipment and wear it properly At the first sign of trouble exit the hazardous area seek help and report the problem to the proper authority B What is a full face respirator The Sundstr m full face respirator consists of an outer mask with polycarbonate or glass visor that covers your face an integrated inner mask with in halation and exhalation valves that covers your nose mouth and chin a rubber strap head harness with 6 mounting points that hold the respirator in place and a filter adapter for connecting standard Sundstr m protective elements C What type of protection will a full face respi rator provide A properly fitted full face respirator can protect you against specific levels of some Particulates Gases and Vapors Viruses and Bacteria Mold and Fiber BUT full face respirators SHOULD NOT b
3. e Place the P100 filter on top of the cartridge Grasp both protective elements e Squeeze hard until you hear the P100 snap onto the cartridge e Pull on the filter and cartridge to check that they are properly connected e Place a pre filter into the pre filter holder e Snap the pre filter holder onto the filter e Check to see that it is firmly attached to the cartridge or filter installing the protective element into the respirator C e Hold the protective element in your hand with the arrows on the label pointing toward the face Insert one part of the large lip of the element into the filter adapter flange Grab the flange with your finger and pull the lip of the adapter flange around the protective element until the entire protective element is seated inside the filter adapter Squeeze the top edge of the element and the bottom edge of the respirator filter adapter together until the filter adapter flange is seated against the edge of the cartridge Make sure that the gasket in the respirator connector is in place screw the filter adapter with the protective element onto the respirator connector Carefully tighten the filter adapter by hand to prevent damage to the thread and to ensure a good seal against the gasket Removing the protective elements from the respirator Screw offthe filter adapter with the protective element from the respirator connector On the top of the respirator filter adapter flange is a
4. No debe entrar aire en el respirador e Retire la palma de la mano del soporte del prefiltro e Respire normalmente 26 Si se detecta alguna p rdida controle las v lvulas de inhalaci n y exhalaci n o ajuste las correas del arn s de cabeza Repita el control de ajuste hasta que no se observe ninguna p rdida C Extracci n e Afloje las cuatro correas el sticas de dos en dos moviendo el soporte hacia delante No es necesario soltar las dos correas r gidas Fig 7 e Tire del arn s hacia delante p selo por encima de la cabeza y extraiga el respirador e Descontamine limpie y almacene el respirador seg n se indica en las instrucciones Aplicaci n de PAPR SR 500 Consulte las instrucciones de colocaci n y extracci n en las instrucciones del usuario P N L67 0121 del SR 500 VI Limpieza y almacenamiento A Desmontaje e Extraiga el adaptador del filtro con el elemento de protecci n e Extraiga las tapas de las v lvulas de exhalaci n y retire las membranas dos e Extraiga las membranas de inhalaci n tres e Extraiga el arn s de cabeza e En caso necesario extraiga la pantalla Consulte el apartado VII A B Limpieza y montaje Unrespirador sucio setraduce en una menor protecci n Se debe elaborar documentar por escrito y seguir un programa de limpieza y desinfecci n Este debe incluir todos los requisitos nacionales y locales e Limpie el respirador con agua caliente jabonosa u otro limpiad
5. gado que no lleva ninguna impresi n en los lados No use este filtro como elemento de proteccion F Qu pasa si no siento olores o si no les doy importancia El da o fisiol gico de algunos contaminantes puede durar mucho tiempo y tardar meses en manifestarse El peligro de estos productos puede ser enmas carado por olores poco familiares o incluso olores agradables Puede ocurrir que un olor no le moleste ni le preocupe pero el contaminante pese a ello puede ser peligroso G Cu ndo sustituyo el filtro o el cartucho Cartucho para productos qu micos Se suele detectar la p rdida de protecci n cuando el usuario siente MOLESTIAS al respirar Si observa cualquiera de los siguientes indicios de peligro abandone la zona peligrosa de inmediato y vuelva a respirar aire puro Compruebe el respirador y sustituya el elemento de protecci n en caso nece sario y si es preciso pida ayuda a Dificultad para respirar mareos o n useas olores b Mareos o n useas c Siente el olor o el sabor de los contaminantes d Cualquier otro efecto f sico que perciba Si usted huele percibe o siente un gusto inusual salga de la zona contaminada compruebe el respira dor y sustituya el elemento de protecci n en caso necesario En ciertos entornos las molestias para respirar pueden ser dif ciles de detectar o pueden producirse muy tarde y no permitir abandonar con seguridad la atm sfera contaminada No es adecuado util
6. l ment protecteur 1 Remplacement des l ments protecteurs A Installation retrait Choisissez la protection appropri e Restez dans une atmosph re s re et choisissez la cartouche et le filtre appropri s B Assemblage de la combinaison cartouche filtre P100 Fig 2 e Placez le filtre P100 au dessus de la cartouche Saisissez les deux l ments protecteurs e Appuyez nergiquement jusqu ce que vous en tendiez un clic Tirez sur le filtre et la cartouche pour v rifier qu ils sont convenablement assembl s e Placez un pr filtre sur le porte prefiltre Encliquetez le porte pr filtre sur le filtre Assurez vous qu il est bien fix sur la cartouche ou le filtre Installation de l l ment protecteur dans le respi rateur e Tenez l l ment protecteur dans votre main avec les fl ches figurant sur l tiquette tourn es vers le visage Ins rez une partie du grand bord de l l ment dans la bride de l adaptateur du filtre e Saisissez la bride avec votre doigt et tirez sur le bord de la bride de l adaptateur autour de l l ment protecteur jusqu ce que l l ment protecteur entier soit log l int rieur de l adaptateur du filtre e Comprimez simultan ment le bord sup rieur de l l ment et le bord inf rieur de l adaptateur du filtre du respirateur jusqu ce que la bride de l adaptateur du filtre soit bien appuy e contre le bord de la car touche e Assurez vous que le joint d
7. quate pour les risques rencontr s sur votre lieu de travail Vous pouvez identifier 10 l ments de protection d apr s la couleur de l tiquette NIOSH MAGENTA Particules poussi res brumes et fum es NOIR Vapeurs organiques JAUNE Vapeurs organiques dioxyde de souffre chlore chlorure d hydrog ne fluorure d hydrog ne BLANC Chlore chlorure d hydrog ne dioxyde de souffre formald hyde VERT Ammoniaque et m thanamine L tiquette d homologation NIOSH DHHS de chaque produit r pertorie les restrictions et les exigences Toutes les tiquettes NIOSH DHHS courantes figurent sur la bo te du respirateur et dans la section IX tiquettes NIOSH DHHS du pr sent manuel Le filtre Sunds tr m P100 peut tre combin toutes les cartouches chimiques afin d apporter l utilisateur une protection combin e contre les vapeurs les gaz et les particules 15 E Que fait le pr filtre Le pr filtre Sundstr m ne peut tre utilis qu avec une cartouche ou un filtre P100 pour r duire les poussi res nuisibles Ceci prolonge la dur e de vie de l l ment pro tecteur en capturant les grosses particules pr venant un chargement pr matur des l ments protecteurs primaires Ce pr filtre n est pas un l ment protecteur AVERTISSEMENT Le pr filtre Sundstr m est un filtre fin sans inscription d aucun c t N utilisez pas ce filtre comme l ment protecteur F Que se passe t il si je ne sens r
8. tanch it dans le connecteur du respirateur soit en place vissez l adaptateur du filtre avec l l ment protecteur sur le connecteur du respirateur Serrez doucement l adaptateur du filtre la main de mani re viter d endommager le filetage et assurer une bonne adh rence contre le joint d tanch it C Retrait des l ments protecteurs du respirateur e D vissez l adaptateur du filtre avec l l ment pro tecteur du connecteur du respirateur e Dans le haut de la bride de l adaptateur du filtre du respirateur se trouve une petite languette touchant le c t de l l ment protecteur e Saisissez d une main l l ment protecteur et la languette entre le pouce et l index de l autre main e Tirez en arri re sur la languette tout en tirant sur la cartouche e Si vous utilisez une combinaison cartouche filtre vous devez maintenant retirer le filtre de la cartouche e Prenez une pi ce de monnaie ou un objet semblable et placez le entre le bord inf rieur du filtre P100 et la petite languette en plastique sur lev e sur le c t de la cartouche Faites levier avec la pi ce jusqu ce que le filtre sorte de la cartouche Fig 3 2 Inspection avant utilisation Avant de mettre le respirateur en place proc dez toujours aux contr les suivants e Assurez vous que le respirateur est propre et sec e V rifiez que le respirateur les valves le harnais et la visi re ne pr sentent aucune trace de fissur
9. tent en donne l ordre e Si vous constatez l Un des sympt mes suivants quittez imm diatement la zone risque Retournez l air frais et demandez de l aide a Difficult respiratoire b Vertiges ou naus es c Vous d celez une odeur ou un go t de conta mination d Tout autre probl me physique perceptible Si la protection appropri e n est pas sp cifi e par l organisme comp tent ou si vous avez des doutes en ce qui concerne l application le choix ou l entretien appropri de cet quipement consultez votre super viseur un professionnel de la s curit ou l organisme local de sant au travail Ne p n trez pas dans une zone suspect e risque Pour obtenir des r ponses vos questions contactez Sundstrom Safety Inc au 1 877 SUNDSTROM lll Introduction Le masques respirateur complet a purification d air APR SR 200 de Sundstr m a t test et homologu par le NIOSH pour conf rer a son utilisateur le niveau de protection respiratoire approuv Assure une protection limit e des yeux ANSI Z87 1 2010 Le respirateur se compose d un masque ext rieur avec visi re en polycarbonate enveloppant enti rement le visage de l utilisateur d un masque int rieur avec valves d inspiration et d expiration qui recouvre le nez la bouche et le menton de l utilisateur d un harnais de t te avec sangles en caoutchouc 6 points de fixation qui maintient le respirateur en place et d un adaptate
10. Do not use for protection against fumigants e This respirator is designed to be used only by TRAINED QUALIFIED PERSONNEL Respirator selection shall be based upon full knowl edge of and professional evaluations of the con taminants and their maximum content in the subject atmosphere Air purifying respirators DO NOT supply oxygen and MUST NOT BE USED in atmospheres containing less than 19 5 oxygen by volume This respirator MUST NOT BE USED for protection against any substance that may cause an allergic reaction that contain Isocyanates or other restricted contaminants or that lack adequate warning proper ties Air purifying respirators shall not be used for structual fire fighting e DO NOT USE this respirator for protection in any atmospheres that are or may become immediately Dangerous to Life or Health IDLH or in conditions that pose an immediate threat by air contaminants that are likely to have adverse delayed effects on life or health e This respirator MUST NOT BE USED for protection against substances that lack adequate warning properties e This respirator is not approved for protection from abrasive blasting including sandblasting operations e This respirator must be equipped with the appropri ate NIOSH approved air purifying filters chemical cartridges or filter cartridge combinations that are properly installed on the respirator e This respirator must be properly fitted to the individual who
11. Suivre le calendrier de remplacement de la car touche et du bo tier filtrant ou observer l ESLI afin de garantir le remplacement des cartouches et des bo tiers filtrants avant d chirure l Contient des parties lectriques qui peuvent causer une source d ignition dans des atmospheres inflam mables ou explosives J Une utilisation ou un entretien inappropri de ce produit peut entra ner la mort ou des blessures L Suivre le mode d emploi fourni par le fabricant pour le remplacement des bo tiers filtrants M Tous les respirateurs homologu s doivent tre s lectionn s install s utilis s et entretenus conform ment au MSHA l OSHA et aux autres r glementations applicables Ne jamais substituer modifier ajouter ou omettre des pi ces Utiliser uniquement les pi ces de remplacement exactes dans la configuration tel que sp cifi par le fabricant 7 O Se reporter au mode d emploi et aux manuels d entretien pour obtenir des informations sur l utilisation et l entretien de ces respirateurs P Le NIOSH n value pas les respirateurs pour une utilisation comme masque chirurgical FF Lajustement des respirateurs doit tre v rifi avant de les utiliser avec les cartouches bo tiers filtres et ou accessoires les plus lourds destin s tre utilis s La v rification de l ajustement doit galement tre faite avec l quipement de protection individuel destin tre utilis Voir le mode d emploi
12. be conducted while wearing all personal protective equipment intended to be used See User s Instruc tions for fit test requirements S Special or critical User s Instructions and or specific use limitations apply ll General respirator use limitations Full face Air Purifying Respirators APR are designed tested and government approved to provide respira tory protection to a properly trained person in certain hazardous atmospheres The wearer must not enter a hazardous atmosphere that meets or exceeds the following limitations Maximum Use Concentrations MUC a 50 times the exposure limit TWA for the con taminant present b Immediately dangerous to life or health IDLH concentrations for the contaminant c The limitations outlined in the applicable NIOSH approval d Any applicable limitations contained in the standards established by a regulatory agency such as federal state and local agencies with jurisdiction over the wearer WARNING This respirator cannot remove all the con taminants from a hazardous atmosphe re Pay close attention to all Maximum Use Concentrations MUC Limitations and other restrictions In addition to these Maximum Use Concentrations MUC Limitations and the warnings and cautions placed in the text the following general safety points must be read and understood by everyone intending to use the Sundstr m respirator e Do not use for paints containing Isocyanates e
13. chloride HF Hydrogen fluoride FM Formaldehyde AM Ammonia MA Methylamine Chemical Cartridges Each chemical cartridge is designed to provide respirato ry protection against specific contaminants A chemical cartridge absorbs and or adsorbs specific vapors and gases from a contaminated atmosphere This process continues until the sorbent becomes saturated and al lows the contaminant to break through OSHA requires a chemical cartridge change out schedule based on workplace aerosol concentration and no longer relies on breakthrough sensory detection to initiate chemical cartridge changing Particulate filters Filters provide protection against particulates All Sundstr m particulate filters trap and hold particles in the filtering media As the amount of the captured con taminant in the media increases breathing resistance also increases Replace the filter when the change in breathing resistance becomes noticeable The P100filter is 99 97 efficient against all particulate aerosols Sundstr m Safety has conducted degradation testing of our P100 filter Our test results show that even after an extensive period exposed to oil based contaminants this filter will not degrade Combination Protective Elements An appropriate chemical cartridge and P100 filter can be combined to provide protection from a combination of certain vapors gases and particulates Pre filter The Sundstr m pre filter is not an protective element a
14. conform ment au MSHA l OSHA et aux autres r glementations applicables N Ne jamais substituer modifier ajouter ou omettre des pi ces Utiliser uniquement les pi ces de remplacement exactes dans la configuration tel que sp cifi par le fabricant O Se reporter au mode d emploi et aux manuels d entretien pour obtenir des informations sur l utilisation et l entretien de ces respirateurs P Le NIOSH n value pas les respirateurs pour une utilisation comme masque chirurgical 11 FF L ajustement des respirateurs doit tre v rifi avant de les utiliser avec les cartouches boitiers filtres et ou accessoires les plus lourds destin s a tre utilis s La v rification de l ajustement doit galement tre faite avec l quipement de protection individuel destin a tre utilis Voir le mode d emploi pour les exigences relatives a la v rification d ajustement S Les modes d emploi sp ciaux ou essentiels et ou les restrictions d utilisation sp cifiques s appliquent ll Restrictions g n rales Les masques respirateurs complets a purification d air APR sont con us test s et homologu s par le gou vernement pour conf rer son utilisateur une protec tion respiratoire dans certaines atmospheres risque Le porteur du masque ne doit pas p n trer dans une atmosphere a risque dont la concentration en contami nants atteint ou d passe les limites suivantes Concentrations maximales d utili
15. d Espigas dos 5 Soporte del prefiltro RO1 0605 6 Adaptador de filtro SR 280 3 H09 0212 7 Junta para acoplar el filtro RO1 1205 8 Correa de transporte RO1 1206 FILTRO CARTUCHOS PREFILTRO Referencia de pedido Cartucho OV SR 218 6 HO2 2121 Cartucho CL HC SD FM SR 231 H02 3621 Cartucho OV SD CL HC HF SR 232H02 3721 Cartucho AM MA SR 229 H02 4821 Filtro P100 SR 510 HO2 1321 Prefiltro SR 221 HO2 0121 ACCESORIOS Referencia de pedido Panos de limpieza SR 5226 HO9 0401 Adaptador para pruebas T01 1202 Etiqueta de identificaci n permanente RO9 0101 Pantalla vidrio laminado T01 1203 Soporte del prefiltro 5153 2 RO1 0604 Disco de comprobaci n de ajuste SR 322 para soporte del prefiltro 5153 2 RO1 0303 Kit de gafas para lentes correctoras SR 341 TO1 1201 Tap n de descontaminaci n RO3 1406 Parachispas SR 336 T01 2001 Pantalla para soldar SR 84 T01 1212 Pelicula protectora SR 343 T01 1204 Pelicula protectora SR 353 T01 1205 Arn s de cabeza de goma T01 1215 Capucha protectora SR 64 HO9 0321 Capucha protectora SR 345 HO9 1021 Amplificador de voz ST2 SR T01 1219 Selecci n de elementos de protecci n Los elementos de protecci n aprobados para su uso con el respirador completo de Sundstr m son 4 cu atro cartuchos de productos quimicos y 1 un filtro de part culas Tambi n hay disponible un prefiltro aprobado para su uso con todos los elementos de protecci n Puede identificar los d
16. dos membranas es decir una a cada lado de la unidad interior de la mascarilla Las espigas de estas membranas son extraibles y deben sustituirse cada vez que se sustituyan las membranas e Saque las membranas y las espigas e Coloque las nuevas membranas sobre las espigas Fig 14 e Las membranas deben asentarse sobre la brida grande es decir hay que pasar la espiga con la membrana desde dentro de la mascarilla a trav s del asiento de la v lvula con la brida m s peque a primero Fig 15 C Sustituci n de las membranas de exhalaci n dos Las membranas de exhalaci n est n montadas sobre una espiga fija en la cara interior de las tapas de las v lvulas a cada lado de la unidad exterior de la mascarilla Las tapas deben sustituirse siempre que se sustituyan las membranas e Suelte las tapas de las v lvulas de los asientos de estas Fig 16 e Saque las membranas Fig 17 e Coloque las membranas nuevas sobre las espigas Compruebe con cuidado que las membranas est n en contacto con los asientos de las v lvulas en todo el contorno e Coloque las tapas de las v lvulas en su posici n Oir un chasquido cuando la tapa haya quedado encajada en su posici n e Realice una comprobaci n del ajuste D Sustituci n del arn s de cabeza El arn s de cabeza solo se puede pedir como recambio completo e Desenganche los soportes de las correas del arn s de cabeza de los anclajes de las correas de la mas carilla
17. rer une protection contre une combinaison de certains types de vapeurs gaz et particules Pr filtre Le pr filtre Sundstr m n est pas un l ment protecteur et ne peut en aucun cas tre utilis comme protection principale ou en remplacement d un filtre P100 ll est con u pour emp cher les particules nuisibles d atteindre les l ments protecteurs Cela permet d accroitre la dur e de vie de l l ment protecteur principal POUR UTILISATION AVEC L APPAREIL DE PRO TECTION RESPIRATOIRE APR A EPURATION D AIR MO TORISE SR 500 Le respirateur complet SR 200 est homologu pour tre utilis avec le ventilateur de l APR a puration d air motoris SR 500 Reportez vous l tiquette d approbation du NIOSH pour les configurations ap prouv es P N L27 0121 En plus de ce manuel le manuel du SR 500 P N L67 0121 doit tre lu et suivi attentivement par toutes les personnes qui ont ou qui auront la responsabilit d utiliser ou de nettoyer le respirateur V Formation de l utilisateur et instructions AVERTISSEMENT Ne terminez pas la formation pour utilisa teurs sans avoir lu et compris toutes les instructions contenues dans ce manuel Ce chapitre de formation s adresse a l utilisateur et a son responsable de la s curit ll contient les informa tions de base indispensables pour instruire en toute s curit les utilisateurs sur les proc dures a suivre pour mettre en place retirer tester et rempla
18. small tab that touches the side of the protective element Grasp the protective element with one hand and this tab with the finger and thumb of the other hand Peel back on the tab while pulling on the cartridge If you are using a stacked cartridge and filter you must now remove the filter from the cartridge Take a coin or similar item and place it in the space between the lower lip on the P100 Filter and the small raised plastic tab on the side of the cartridge Twist the coin until the filter pops off the cartridge Fig 3 2 Inpection prior to use Before donning the respirator always perform the following checks Ensure that the respirator is clean and dry Check the respirator valves harness and visor for cracks missing parts and other defects Check that the appropriate chemical cartridge filter or combination is installed properly 3 Donning Fit check Doffing A Donning Remove any hood glasses or ear protection from head Slacken the four elastic straps by moving the strap holders forward at the same time pulling the straps Fig 4 Slacken the upper two inelastic straps by opening the buckles Move the head harness upwards place your chin in the facepiece chin support and pull the head harness over your head Fig 5 e Tension the elastic straps in pairs by pulling the free strap ends towards the rear Fig 6 e Adjust the lengths of the upper pair of straps and fix by means of the buckles e Adju
19. AFO EL PROVEEDOR NO OFRECE DECLARACIONES NI GARANTIAS DE NINGUN TIPO NATURALEZA O CARACTER EX PLICITAS NI IMPLICITAS INCLUIDA SIN LIMITES CUALQUIER GARANTIA DE COMERCIALIZACION APTITUD DE CUALQUIERA DE LOS PRODUCTOS PARA CUALQUIER USO ESPECIAL O DE NO INFRAC CION DE OTROS DERECHOS DECLINANDO TODA RESPONSABILIDAD POR LAS MISMAS Para hacer valer los derechos que le otorga esta garant a envie el Producto a su distribuidor junto con una descrip ci n por escrito del supuesto defecto y el comprobante de compra Su distribuidor enviar el Producto al Proveedor para evaluar la validez de su reclamaci n IX Ilustraciones p gina 29 X Etiquetas del NIOSH DHHS Consulte las p ginas adjuntas 5 a wn Gas filter 29 su ID tag tiquette ID Etiqueta de identificaci n The label can withstand washing and will normally i last throughout the life of the mask 20000 L tiquette supporte le lavage et doit normalement Quienspuns durer autant que le masque Mile La etiqueta soporta el lavado y normalmente dura Smi Ha toda la vida de servicio de la careta 72 06 Fold flap away before writing Seal entry field Soulever la languette avant d crire Recouvrir la partie crite Aparte la solapa al escribir Precinte el espacio para escribir Insert label half way Remove prot
20. DVERTENCIA La formaci n del usuario no debe concluir sin antes leer y comprender todas las instruccio nes contenidas en este folleto Este apartado de formaci n est dirigido al usuario y a su encargado de seguridad Contiene la informaci n m nima indispensable para instruir a los usuarios de forma segura en la colocaci n extracci n compro baci n y sustituci n de los elementos de protecci n del respirador de Sundstr m Este procedimiento de formaci n se incluye como complemento delas instruc ciones contenidas en el resto del presente manual Seg n las condiciones locales puede que se necesiten instrucciones adicionales Sundstr m alienta al pro fesional de seguridad encargado del programa de equipos respiratorios a a adir toda la informaci n local posible para aumentar la seguridad de los trabajadores y complementar este texto b sico Pida a su distribuidor Sundstr m m s cercano la gu a del instructor 1 POR QU USAR UNA PROTECCI N RESPIRATORIA A Por qu es necesaria la protecci n respiratoria La protecci n respiratoria es necesaria siempre que se est en una atm sfera que puede ser nociva para la salud Seg n la sustancia presente en la atm sfera contaminada puede existir riesgo de 23 DANO PULMONAR Bronquitis edema neumonia DANOS EN ORGANOS VITALES Ri ones higado cerebro CANCER INVALIDEZ PERMANENTE Asma silicosis asbestosis o enfisemas o en el peor de los casos LA
21. Figs 18 y 19 e Compruebe que las correas no est n torcidas y coloque el nuevo arn s de cabeza 27 VIII Garantia El Proveedor garantiza a todo comprador del Producto que sea usuario final del mismo que el Producto no presentara defectos de material ni de fabricaci n salvo el uso y desgaste normales durante un afio a partir de la fecha de compra del Producto por parte del usuario final Adem s el Proveedor garantiza que el Producto cumple con las normas del NIOSH vigentes en la fecha de compraventa La unica obligaci n del Proveedor y la unica compensaci n que esta garantia ofrece al usuario final se limita al cambio de cualquier Producto cubierto por esta garantia que presente un defecto cubierto por esta garantia durante el periodo de validez de la misma La garant a no sera valida para Productos que hayan sido modificados utilizados incorrectamente hayan sufrido un accidente o fueran usados incumpliendo las especificaciones y recomen daciones del Proveedor o una vez expirada su vida util ni tampoco para Productos cuyo embalaje haya sido modificado o abierto antes de la compra por parte del usuario final El Proveedor no ofrece declaraciones ni garantias de ningun tipo en relaci n con la aplicaci n o efectos de cualquier ley internacional nacional regional o local ordenanzas normas o reglamentos que puedan regular en este momento o en el futuro el uso de este Producto SALVO LO EXPRESAMENTE ESTIPULADO EN ESTE PARR
22. MUERTE ADVERTENCIA No entre en un entorno contaminado o des conocido sin haber preguntado al encargado de seguridad qu tipo de protecci n se ne cesita Utilice todo el equipo de protecci n y ll velo correctamente Ante el primer indicio de peligro abandone la zona contaminada pida ayuda e informe del problema a la au toridad competente B 2046 es un respirador completo El respirador completo de Sundstr m consta de una unidad exterior con pantalla de policarbonato o vidrio que le cubre la cara una unidad interior integrada con valvulas de inhalaci n y exhalaci n que le cubre la nariz la boca y el ment n un arn s de cabeza con correas de goma y 6 puntos de sujeci n que fijan el respirador en su sitio y un adaptador del filtro para acoplar los elementos de protecci n est ndar de Sundstr m C Qu tipo de protecci n brinda un respirador completo Un respirador completo bien ajustado protege contra niveles especificos de determinadas Particulas Gases y vapores Virus y bacterias Moho y fibras PERO utilizarse En atm sferas con deficiencia de oxigeno En atm sferas de peligro inmediato para la vida o la salud IDLH Si se desconocen los contaminantes ADVERTENCIA Tenga presente los limites maximos de uso y siga las instrucciones de su encargado de seguridad los respiradores completos NO DEBEN 24 D C mo saber qu tipo de filtro o cartucho utilizar Su encargado de seguridad
23. RIDGES PRE FILTER Order Number OV Cartridge SR 218 6 HO2 2121 CL HC SD FM Cartridge SR 231 H02 3621 OV SD CL HC HF Cartridge SR 232 HO2 3721 AM MA Cartridge SR 229 HO2 4321 P100 filter SR 510 HO2 1321 Pre filter SR 221 HO2 0121 ACCESSORIES Order Number Cleaning Wipes SR 5226 HO9 0401 Test adapter TO1 1202 Permanent ID tag RO9 0101 Visor laminated glass T01 1203 Pre filter holder 5153 2 RO1 0604 Fit check disc SR 322 for pre filter holder 5153 2 RO1 0303 Spectacle kit for corrective lenses SR 341 T01 1201 Decontamination Cap RO3 1406 Spark Arrester SR 336 T01 2001 Welding Cassette SR 84 T01 1212 Protective Film SR 343 T01 1204 Protective Film SR 353 TO1 1205 Rubber Head Harness TO1 1215 Protective Hood SR 64 HO9 0321 Protective Hood SR 345 H09 1021 SmallTalk Voice Amplifier ST2 SR T01 1219 Selection of protective elements The protective elements approved for use on the Sund str m Full face Respirator are 4 chemical cartridges and 1 particulate filter A pre filter is also approved for optional use with all protective elements You can identify various protective elements by the color and protection designation of the NIOSH filter cartridge label MAGENTA P100 BLACK OV YELLOW OV SD CL HC HF WHITE CL HC SD FM GREEN AM MA P100 Particulate filter 99 97 filter efficiency level effective against all particulate aerosols OV Organic vapor SD Sulfur dioxide CL Chlorine HC Hydrogen
24. Rangement Rangez le respirateur les filtres et les cartouches dans un endroit propre frais et sec l abri de la lumi re directe du soleil La dur e de conservation des l ments protecteurs dans leur bo te d origine non ouverte est de 10 ans pour les filtres particules et 5 ans pour les cartouches chimiques La date limite d utilisation est imprim e sur l tiquette sous la forme suivante mois ann e par exemple mai 2012 VII Pi ces de rechange Utilisez exclusivement des pi ces Sundstr m d origine Ne modifiez pas l quipement L utilisation de pi ces pirat es ou la modification du mat riel peut r duire la fonction protectrice et compromettre les homologa tions du produit 18 A Remplacement de la visi re La visi re est ins r e dans une cannelure qui fait le tour de l ouverture de la visi re dans le masque ext rieur et est maintenue en place par un demi cadre sup rieur et inf rieur e D posez les deux vis qui maintiennent ensemble les moiti s de cadre au moyen d une clef Allen de 2 5 mm Fig 8 e Retirez avec pr caution la moiti de cadre sup rieure Fig 9 e D gagez avec pr caution la partie sup rieure du masque de la visi re et sortez la visi re de la can nelure inf rieure Fig 10 11 Profitez en pour nettoyez la cannelure si n cessaire e La visi re les moiti s de cadre et le masque compor tent un rep re indiquant le milieu Fig 12 Introduisez la visi
25. Sundstr m Este manual solo incluye los elementos b sicos de un programa completo para respiradores purificadores del aire Un programa debidamente dise ado para respiradores tambi n incluye pruebas de ajuste documentaci n correcta y gesti n activa por parte del profesional de seguridad local Todas las normas y recomendaciones contenidas en los documentos OSHA y en particular 29 CFR 1910 134 las normas EPA la norma Z88 2 del Instituto Nacional Estadounidense de Normas ANSI y todas las normas nacionales regio nales y locales deben mencionarse en el programa de seguridad completo 22 Este respirador no debe utilizarse sin conocer a fondo todos sus componentes y su funci n Lea este folleto completo detenidamente y cons ltelo siempre que tenga alguna duda Asimismo antes de entrar en una atm sfera peligrosa debe cumplir satisfactoriamente con todos los requisitos de formaci n exigidos por ley y locales Sino se leen comprenden y siguen estrictamente estas instrucciones antes de utilizar el producto podr an producirse lesiones o incluso la muerte IV Gu a de configuraci n y selecci n RESPIRADOR COMPLETO Configuraci n fig 1 Componente Referencia de pedido 1 Pantalla de policarbonato RO1 1201 2 Mitad superior del armaz n con tornillos RO1 1202 3 Arn s de cabeza RO1 1203 4 Juego de membranas RO1 1204 a Membranas de exhalaci n dos b Tapas de valvula dos c Membranas de inhalaci n tres
26. a ada u omita piezas Utilice nicamente las piezas de recambio exactas seg n la configuraci n especificada por el fabri cante O Paraobtener informaci n acerca del uso y manten imiento de estos respiradores consulte las instruc ciones de uso y o los manuales de mantenimiento El NIOSH no eval a los respiradores en cuanto a usos quir rgicos FF Deber probarse el ajuste de los respiradores antes de su uso con los modelos de mayor peso de los cartuchos recipientes filtros y o accesorios que utilizar Tambi n deber efectuarse una compro baci n del ajuste con todo el equipo de protecci n personal que se va a utilizar puesto Consulte los requisitos de las pruebas de ajuste en las instruc ciones de uso S Sonde aplicaci n las instrucciones de uso especia les o cr ticas y o las limitaciones de uso especificas ll Limitaciones generales de uso del respirador Los respiradores completos purificadores de aire han sido dise ados probados y oficialmente aprobados para ofrecer protecci n respiratoria a personas de bidamente formadas en determinadas atm sferas peligrosas El usuario no debe entrar en atm sferas peligrosas que alcancen o superen los siguientes limites Concentraci n m xima de uso CMU a 50 veces el umbral de exposici n TWA o l mite de exposici n promedio ponderado en el tiempo al t xico presente b T xico en concentraciones que suponen un peli gro inmediato para la vida
27. bly e Remove the filter adapter with protective element e Remove the covers from the exhalation valves and remove the membranes two e Remove the inhalation membranes three e Remove the head harness e f necessary remove the visor See section VII A B Cleaning and assembling A dirty respirator causes reduced protection A written program for cleaning and sanitizing should be established and followed This program should include all federal and local requirements e Clean with warm soapy water or other respirator cleaner and a soft brush lint free cloth or sponge Do not exceed 104 F 40 C Never use solvents for cleaning e Sanitize the respirator Use any approved sanitizing or disinfecting agent or a solution of 2 tablespoons of household bleach mixed in one gallon of water 60 PPM chlorine or 1 teaspoon of tincture of iodine 50 PPM iodine in one gallon of water Immerse the respirator in the solution for at least 2 minutes e Rinse thoroughly e Check the condition of the respirator and all the parts Replace any damaged or defective item e Shake the respirator to remove excess water and allow to dry e Perform a quick fit check C Storage Store the respirator filters and cartridges in a clean cool dry place out of direct sunlight Shelflife for ptotective elements in unopened packages Particulate filter 10 years chemical cartridge 5 years The expiration date is printed on the label mon
28. cer les l ments protecteurs du respirateur Sundstr m Cette proc dure de formation vient suppl er les instruc tions fournies dans le reste du pr sent manuel Les conditions locales peuvent exiger des instructions suppl mentaires Sundstr m encourage la personne en charge de la s curit pour le programme respiratoire ajouter toutes les informations locales possibles en vue d accroitre la s curit des employ s et de compl ter ce texte de base Vous pouvez vous procurer un Guide desinstructeurs aupr s de votre distributeur Sundstr m le plus proche 1 POURQUOI UTILISER UNE PROTETION RESPIRATOIRE A Pourquoi est il n cessaire de porter une pro tection respiratoire Une protection respiratoire est n cessaire chaque fois que vous vous trouvez dans une atmosph re sus ceptible de nuire votre sant Selon les substances pr sentes dans l atmosph re contamin e vous courrez un risque de MALADIE PULMONAIRE Bronchite ced me pneumonie DOMMAGES DES ORGANES VITAUX Reins foie cerveau CANCER INVALIDIT PERMANENTE Asthme silicose asbestose ou emphys me ou pire encore MORT AVERTISSEMENT Ne p n trez pas dans une atmosph re dangereuse ou inconnue sans deman der votre responsable de la s curit le type de protection obligatoire Utilisez tout l quipement de protection et portez le de mani re appropri e D s les premiers sig nes de malaise probl me quittez la zone dangereuse d
29. ches chimiques Chaque cartouche chimique est con ue pour assurer une protection respiratoire contre des contaminants sp cifiques Une cartouche chimique absorbe et ou adsorbe les vapeurs et gaz sp cifiques provenant d une atmosph re contamin e Ce processus continue jusqu ce que le sorbant devienne satur et laisse p n trer le contaminant LOSHA exige qu un calendrier de remplacement de la cartouche chimique soit bas sur la concentration des a rosols en milieu de travail et non sur la d tection sensorielle d une fuite pour initier le remplacement de la cartouche chimique 14 Filtres particules Les filtres conf rent une protection contre les parti cules Tous les filtres particules Sundstr m pi gent et retiennent les particules dans le mat riau filtrant La r sistance respiratoire augmente proportionnellement l augmentation de contaminants captur s dans ce mat riau Remplacez le filtre lorsque la modification de la r sistance respiratoire devient perceptible Le filtre P100 est efficace 99 97 en ce qui concerne tous les a rosols particulaires Sundstr m Safety a effectu un essai de d gradation sur notre filtre P100 Nos r sultats de tests d montrent que ce filtre ne se d grade pas m me apr s une longue p riode d exposition des contaminants base d huile Combinaison d l ments protecteurs ll est possible de combiner une cartouche chimique et un filtre P100 appropri s pour conf
30. de la pr sente garantie sont limit s au remplacement de tout Produit couvert par la pr sente garantie qui s av re tre en contravention avec celle ci au cours de sa p riode de validit La garantie ne s applique pas aux Produits qui ont t modifi s mal utilis s accident s utilis s contrairement aux sp cifica tions et auxrecommandations du fournisseur ou utilis s au del de leur vie utile ni aux Produits dont l emballage a t modifi ou ouvert avant l achat par l utilisateur final Le fournisseur ne donne aucune assurance ni garantie en ce qui concerne l application ou l effet de n importe quelle l gislation ordonnance r gle ou r glementation internationale f d rale d tat ou locale qui peut pr sent ou ult rieurement avoir un rapport avec l utilisation ou l exploitation du Produit SAUF DIS POSITION EXPRESSE DU PRESENT PARAGRAPHE LE FOURNISSEUR NE DONNE AUCUNE ASSURANCE NI GARANTIE DE QUELLE QUE NATURE OU ESP CE QUE CE SOIT EXPRESSE OU IMPLICITE Y COMPRIS SANS S Y LIMITER AUCUNE GARANTIE DE VAL EUR COMMERCIALE D APTITUDE DE N IMPORTE LEQUEL DES PRODUITS A UNE FIN PARTICULI RE QUELCONQUE OU DE NON CONTREFA ON INDUS TRIELLE ET PAR LA PR SENTE RENONCE DONNER DE TELLES ASSURANCES O GARANTIES Afin de faire valoir vos droits au titre de la pr sente garantie veuillez renvoyer le produit votre distributeur accompagn d une description crite du d faut invoq
31. do el adaptador del filtro manual mente para evitar que se da e la rosca y garantizar un sellado correcto con la junta C Extracci n de los elementos protectores del respirador e Desenrosque el adaptador del filtro junto con el elemento de protecci n del conector del respirador e En la parte superior de la brida del adaptador del filtro del respirador hay una peque a leng eta que toca el lateral del elemento de protecci n e Tomeelelemento de protecci n con una mano y esta leng eta con el pulgar y el ndice de la otra mano e Tire de la leng eta hacia atr s a la vez que tira del cartucho e Si est usando el cartucho y filtro apilados debe separar el filtro del cartucho en este momento e Tome una monedao similar y col quela entre el borde inferior del filtro P100 y la leng eta pl stica peque a levantada del lateral del cartucho Gire la moneda hasta que el filtro se suelte del cartucho Fig 3 25 2 Inspecci n previa al uso Antes de colocarse el respirador realice siem pre las siguientes comprobaciones e Asegurese de que el respirador est limpio y seco e Compruebe que el respirador las v lvulas el arn s y la pantalla no presentan grietas que no les falten piezas u otros defectos e Compruebe que el cartucho para productos quimi cos el filtro o la combinaci n de ambos est cor rectamente instalado 3 Colocaci n comprobaci n del ajuste y extracci n A Colocac
32. e e Installer de l l ment protecteur e Appuyez sur le porte pr filtre jusqu ce qu il s encliquette sur la cartouche ou le filtre e Mise en place du respirateur e Pressez l g rement la paume de la main sur le trou du porte pr filtre afin de cr er l tanch it Fig 20 REMARQUE N appuyez pas trop fort afin de ne pas d former le respirateur e Inspirez doucement le respirateur doit s affaisser contre le visage e Retenez votre respiration pendant quelques sec ondes l air ne doit pas pouvoir entrer dans le respi rateur e Retirez la paume de la main du porte pr filtre e Respirez normalement Si une fuite est d tect e v rifiez les valves d inhalation et d exhalation ou ajustez les sangles du harnais de t te V rifiez l ajustement jusqu ce qu il n y ait plus de fuite C Retrait e Detendez par paires les quatre sangles lastiques en amenant vers l avant le support des sangles Les deux sangles non lastiques n ont pas besoin d tre d faites Fig 7 e Amenez le harnais de t te sur le devant en le faisant passer sur la t te et retirez le respirateur e Nettoyez et rangez le respirateur conform ment aux instructions Utilisation d un APR a puration d air motoris SR 500 Pour les instructions de mise en place et de retrait reportez vous au mode d emploi P N L67 0121 de PAPR puration d air motoris SR 500 17 VI Nettoyage et rangement A D montage e D tachez
33. e pi ce manquante ou autre d faut e Assurez vous que la cartouche chimique le filtre ou la combinaison appropri e est correctement install e 3 Mise en place Contr le d tanch it k Retrait A Mise en place e Retirez la cagoule les lunettes ou les protections d oreille que vous portez e D tendez les quatre sangles lastiques en amenant sur le devant les supports des sangles tout en tirant sur l lastique Fig 4 D tendez les deux sangles sup rieures non lastiques en ouvrant les deux boucles e Amenez le harnais de t te sur le dessus placez le menton dans le logement pr vu a cet effet dans le masque int rieur et faites passer le harnais sur la t te Fig 5 e Tendez les sangles lastiques par paire en tirant vers l arri re sur l extr mit libre des sangles Fig 6 e Ajustezlalongueur dela paire de sangles sup rieures et bloquez la avec les boucles e Ajustez le masque sur le visage de sorte qu il soit positionn de mani re stable et confortable e Proc dez un contr le d tanch it l inspiration et l expiration B Contr le d tanch it AVERTISSEMENT Proc dez un contr le d tanch it chaque fois que le respirateur doit tre port Si vous n assurez pas une tanch it conve nable entre le visage et le respirateur avant de p n trer dans une atmosph re risque vous vous exposez une protection respi ratoire insuffisante ou totalement absent
34. e la unidad exterior y se fija en su posici n con la mitad superior y la mitad inferior del armaz n e Utilice una llave Allen de 2 5 mm para extraer los dos tornillos que mantienen unidas ambas mitades del armaz n Fig 8 e Extraiga con cuidado la mitad superior del armaz n Fig 9 e Extraiga con cuidado la parte superior de la mas Carilla de la pantalla y luego suelte la pantalla de la ranura inferior Figs 10 y 11 Aproveche para limpiar la ranura en caso necesario e Hay unas marcas que se alan el centro de la pantalla de las mitades del armaz n y de la mascarilla Fig 12 Inserte la nueva pantalla en la ranura asegur ndose de que las marcas centrales quedan alineadas Para facilitar el montaje aplique una soluci n jabonosa o un l quido similar en la ranura e Coloque cuidadosamente la mitad superior de la mascarilla sobre la pantalla y aseg rese de que esta queda insertada en la ranura de la mascarilla Fig 10 e Coloque la mitad superior del armaz n y aseg rese de que las marcas centrales quedan alineadas Fig 12 e Introduzca los tornillos y apri telos alternativamente hasta que las dos mitades del armaz n queden bien unidas Fig 8 e Realice una comprobaci n del ajuste B Sustituci n de las membranas de inhalaci n tres e Una de las membranas est situada en el centro de la unidad interior de la mascarilla sobre una espiga fija Saque esta membrana y coloque una nueva Fig 13 e Secolocan
35. e used In oxygen deficient areas In atmospheres Immediately Dangerous to Life and Health IDLH When the contaminants are unknown WARNING Know your Maximum Use Limitations and follow the instructions of your safety pro fessional D How do I know which filter or cartridge to use Your safety professional is responsible for providing you information concerning what filter cartridge or combination will provide adequate protection for the hazards at your worksite You can identify various 10 protective elements by the color of the NIOSH label MAGENTA Particles Dust Mists and Fumes BLACK Organic Vapors YELLOW Organic Vapors Sulfur Dioxide Chlorine Hydrogen Chloride Hydrogen Fluoride WHITE Chlorine Hydrogen Chloride Sulfur Dioxide Formal dehyde GREEN Ammonia and Methylamine The NIOSH DHHS approval label for each product lists limitations and requirements All current NIOSH DHHS labels can be found in the respirator box printed on a sheet titled Section X NIOSH DHHS LABELS of this manual The Sundstr m P100 filter can be combined with each chemical cartridge to give the user combined vapor gas and particulate protection E What does the pre filter do The Sundstr m pre filter can only be used with a cartridge or P100 filter to reduce nuisance dusts This extends the life of the protective element by capturing these large particulates preventing prema ture loading of the primary protective el
36. ective paper and stick label together Enfoncer demi l tiquette Enlever la papier protecteur et coller l tiquette Introduzca la etiqueta hasta la mitad Quite el papel de protecci n y adhiera ambas partes de la etiqueta 33 34 NOTES NOTES 35 67808102 LE APY 001 217 Sundstr m J
37. el Prise off the membrane and fit a new membrane Fig 13 e Two membranes are fitted i e one on each inside of the inner mask The dowels for these membranes are removable and should be changed whenever the membranes are changed e Prise off the membranes and dowels e Prise the new membranes onto the dowels Fig 14 e The membranes should rest on the larger flange i e thread the dowel with the mem brane from the inside of the facepiece through the valve seat with the smaller flange first Fig 15 C To change the exhalation membranes two The exhalation membranes are mounted on a fixed dowel on the inside of the valve covers on each side of the outer facepiece The covers should be changed whenever the membranes are changed e Snap the valve covers off the valve seats Fig 16 e Prise off the membranes Fig 17 e Press the new membranes onto the dowels Carefully check that the membranes are in contact with the valve seats all round e Press the valve covers into place A clicking sound indicates that the cover has snapped into place e Perform a fit check D To change the head harness The head harness can be ordered as a spare part only as a complete harness e Snap the strap holders of the head harness off the facepiece strap mountings Fig 18 19 e Check that the straps are not twisted and fit the new head harness VIII Warranty Supplier warrants to each purchaser of a Product who is an end user o
38. emandez de l aide et signalez le probl me l autorit comp tente B Qu est ce qu un respirateur complet Le respirateur complet Sundstr m se compose d un masque ext rieur avec visi re en polycarbonate ou en verre feuillet enveloppant enti rement le visage d un masque int rieur avec valves d inspiration et d expira tion qui recouvrent le nez la bouche et le menton de l utilisateur d un jeu de sangles 6 points de fixation qui maintient le respirateur en place et d un adaptateur de filtre avec filet standard permettant de raccorder un filtre standard Sundstr m C Quel type de protection apporte un respira teur complet Un respirateur complet correctement ajust peut vous prot ger contre des niveaux sp cifiques de Particules Gaz et vapeurs Virus et bact ries oisissures et fibres MAIS les respirateurs complets NE DOIVENT PAS tre utilis s Dans des zones d ficientes en oxyg ne Dans des atmosph res qui pr sentent un danger imm diat pour la vie ou la sant IDLH Lorsque les contaminants sont inconnus AVERTISSEMENT Avertissement Vous devez connaitre les restrictions maximales d utilisation et suivre les instructions de votre responsable de la s curit D Comment savoir quel filtre ou cartouche utiliser Votre responsable de la s curit se chargera de vous fournir les informations concernant le type de filtre car touche ou combinaison qui vous fournira la protection ad
39. ements This pre filter is not a protective element WARNING The Sundstr m pre filter is a thin filter that does not have any printing on either side Do not use this filter as a protective element F What if I can t smell anything or don t mind the smell The physiological damage from some contaminants can be long term and many take months to appear The danger from these hazards may be masked by an unfamiliar or even pleasant odor A certain smell or odor may not bother you or cause you discom fort but the contaminant can still be hazardous G When do I change the filter or cartridge Chemical Cartridge Loss of protection is frequently detected when the user experiences BREAKTHROUGH If you experience any one of the following danger signals leave the hazardous area immediately return to fresh air Check your respirator and replace the protective element if necessary and seek any neces sary assistance a Breathing difficulty dizziness or nausea smell b Dizziness or nausea c You smell or taste the contaminants d Any other noticeable physical effect If you smell feel or taste anything unusual leave the contaminated area check your respirator and replace the protective element if necessary In some atmospheres breakthrough may be hard to detect or may occur too late to provide you a safe exit from the contaminated atmosphere An air purifying respirator is not appropriate for use However under cer
40. euvent tre utilis es mais doivent tre remplac es apr s un temps d exposition donn Ce calendrier est d fini par une autorit comp tente et contr l par votre responsable de la s curit 16 AVERTISSEMENT Avertissement Une cartouche chimique vide laissera passer les fum es ou vapeurs dangereuses L utilisateur peut ne pas constater de changement de sa r sistance respiratoire Suivez les proc dures locales et tous les avertissements contenus dans le manuel d utilisation Filtres Les filtres liminent les particules contenues dans l air en capturant les particules solides et en lais sant l air respirable entrer dans le respirateur Au fur et mesure que le filtre se charge de ces particules l inspiration devient de plus en plus inconfortable Lorsque vous constatez une augmentation de votre r sistance l inspiration quittez la zone contamin e et remplacez le pr filtre ou le filtre protecteur si n cessaire Des restrictions quant la dur e d utilisation peuvent galement s appliquer certains filtres lorsque l efficacit diminue ou lorsqu ils sont expos s des contaminants sp cifiques Les filtres doivent tre remplac s d s que ces limites sont atteintes Pr filtre Le pr filtre contre les particules nuisibles abordable est utilis avec une cartouche ou un filtre P100 Lorsque votre r sistance respiratoire augmente commencez par remplacer le pr filtre Si elle ne diminue pas remplacez l
41. f such Product that the product is free 10 from defects in material and workmanship ordinary wear and tear excepted for one year from date of purchase by such end user Further Supplier warrants that the Product conforms to the NIOSH standards in effect on that date of sale Supplier s sole obligation and each end users sole and exclusive remedy under this warranty shall be limited to replacement of any Product covered by this warranty which proves in viola tion of such warranty during the period of effectiveness thereof The warranty shall not apply to any Product which has been altered misused subjected to an ac cident used contrary to Supplier s specifications and recommendations or used beyond it s useful life or to any Product whose packaging has been altered or opened prior to purchase by the end user Supplier makes no representations or warranties concerning the application or effect of any international federal state or local laws ordinances rules or regulations which may now or hereafter pertain to the use or operation of the Product EXCEPT AS EXPRESSLY PROVIDED IN THIS PARAGRAPH SUPPLIER MAKES NO REPRESENTATIONS OR WARRANTIES OF ANY KIND NATURE OR DESCRIPTION EXPRESSED OR MPLIED INCLUDING WITHOUT LIMITATION ANY WARRANTY OF MERCHANTABILITY FITNESS OF ANY OF THE PRODUCTS FOR ANY PARTICULAR PURPOSE OR NON INFRINGEMENT AND HEREBY DISCLAIMS THE SAME n order to assert your ri
42. ghts under this warranty please return the Product to your vendor together with a written description of the alleged defect and proof of purchase Your distributor will forward the Product to Supplier for analysis of the validity of your claim IX Illustrations page 29 X NIOSH DHHS labels See insert pages Masque complet SR 200 I Limitations d approbation du NIOSH Il Restrictions g n rales l utilisation du respirateur Ill Introduction IV Configuration et guide V Formation de l utilisateur et instructions 1 Remplacement des l ments protecteurs 2 Inspection avant utilisation 3 Mise en place V rification d ajustement Retrait VI Nettoyage et rangement VII Pi ces de rechange VIII Garantie IX Illustrations XI Etiquettes du NIOSH DHHS encarts s par s inclus dans cette brochure l Limitations d approbation Note Les avertissements et les limitations ne s appliquent pas toutes les utilisations Reportez vous l tiquette d approbation du NIOSH en encart dans le document ajoutez la r f rence pour v rifier les avertissements et les limitations applicables Utilisation d un APR cartouche chimique A Ne pas utiliser dans une atmosph re dont la teneur en oxyg ne est inf rieure 19 5 B Ne pas utiliser dans une atmosph re pr sentant un danger imm diat pour la vie ou la sant C Ne pas d passer les concentrations d utilisation maximales tablies par les normes obligatoires H
43. i n e Qu tesela capucha las gafas o la protecci n auricular si las lleva e Aflojelas cuatro correas el sticas moviendo el soporte hacia delante al mismo tiempo que tira de las cor reas Fig 4 Afloje las dos correas r gidas superiores abriendo las hebillas e Levante el arn s de cabeza coloque el ment n en el soporte para el mismo de la mascarilla y pase el arn s de cabeza sobre su cabeza Fig 5 e Tense las correas el sticas de dos en dos tirando de los extremos libres hacia atr s Fig 6 e Ajuste el largo del par superior de correas y fijelo en su posici n con las hebillas e Ajuste la mascarilla a su cara de forma que quede colocada firme pero c modamente e Realice una comprobaci n del ajuste B Comprobaci n del ajuste ADVERTENCIA Cada vez que se use el respirador debe reali zarse una correcta comprobaci n del ajuste Si no consigue un sellado adecuado del re spirador contra la cara antes de entrar en un entorno peligroso la protecci n respiratoria podr ser baja o nula e Instale del elemento de protecci n e Enganche el soporte del prefiltro sobre el cartucho o el filtro e Colocaci n del respirador e Ubique la palma de la mano sobre el orificio del soporte del prefiltro con delicadeza Fig 20 Nota No ejerza mucha presi n ya que la forma del respirador se puede ver afectada e Aspire suavemente El respirador debe plegarse hacia la cara e Contenga la respiraci n unos segundos
44. i n de los elementos de protecci n A Instalaci n extracci n Elija la protecci n adecuada Permanezca en un entorno seguro y seleccione el cartucho y el filtro adecuados B Montaje de la combinaci n de cartucho y filtro P100 Fig 2 e Coloque el filtro P100 por encima del cartucho Una ambos elementos de protecci n Apriete con fuerza hasta que oiga que el filtro P100 ha encajado en el cartucho Tire del filtro y el cartucho para comprobar si est n bien unidos e Coloque un prefiltro en el soporte respectivo e Encaje el soporte del prefiltro en el filtro e Compruebe que est firmemente sujeto al cartucho o el filtro lInstalaci n del elemento de protecci n en el respirador e Sujete el elemento de protecci n en la mano con las flechas de la etiqueta apuntando hacia su cara Introduzca una parte del borde grande del elemento en la brida del adaptador de filtro Tomela brida con los dedos y tire del borde de la brida del adaptador que rodea el elemento de protecci n hasta que este quede totalmente colocado dentro del adaptador del filtro Apriete la esquina superior del elemento y la esquina inferior del adaptador del filtro del respirador hasta que la brida del adaptador del filtro toque la esquina del cartucho Aseg rese de que la junta del conector del respirador est bien colocada y atornille el adaptador del filtro junto con el elemento de protecci n al conector del respirador Apriete con cuida
45. icas y o las limitaciones de uso espec ficas A continuaci n se indican las precauciones y limi taciones del NIOSH referentes alas aplicaciones del respirador purificador de aire motorizado PAPR A Not for use in atmospheres containing less than A Nose debe utilizar en atm sferas con un contenido de ox geno inferior al 19 5 B Nose debe utilizar en atm sferas que representen un peligro inmediato para la vida o la salud C No supere las concentraciones m ximas de uso contempladas en las normas reglamentarias F No utilice respiradores purificadores de aire mo torizados PAPR si el caudal de aire es inferior a 4 ft3 min 115 l min para ajustar las mascarillas o 6 ft3 min 170 l min para capuchas y o cascos H Respete los calentarios de sustituci n del cartucho y el recipiente o siga las normas ESLI para asegurarse de que los cartuchos y recipientes se sustituyen antes de que se produzcan roturas l Incluye componentes el ctricos que pueden convertirse en la fuente de ignici n de atm sferas inflamables o explosivas J El uso o mantenimiento inadecuado de este pro ducto puede causar lesiones o incluso la muerte L Siga las instrucciones de uso del fabricante para sustituir los recipientes M La selecci n el ajuste la utilizaci n y el manten imiento de todos los respiradores aprobados debe llevarse a cabo de conformidad con las normas MSHA OSHA y otras normas aplicables N Nunca sustituya modifique
46. ications A Not for use in atmospheres containing less than 19 5 percent oxygen B Not for use in atmospheres immediately dangerous to life or health C Do not exceed maximum use concentrations es tablished by regulatory standards F Do not use powered air purifying respirators if air flow is less than four cfm 115 lpm for tight fitting facepieces or six cfm 170 lpm for hoods and or helmets H Follow established cartridge and cartridge change schedules or observe ESLI to ensure cartridges and canisters are replaced before breakthrough occurs Contains electrical parts that may cause an ignition source in flammable or explosive atmospheres J Failure to properly use and maintain this product could result in injury or death L Follow the manufacturer s User s Instructions for changing canisters M All approved respirators shall be selected fitted used and maintained in accordance with MSHA OSHA and other applicable regulations N Never substitute modify add or omit parts Use only exact replacement parts in the configuration as specified by the manufacturer O Refer to User s Instructions and or maintenance manuals for information on use and maintenance of these respirators P NIOSH does not evaluate respirators for use as surgical masks FF Respirators are to be fit tested prior to use with the heaviest cartridges canisters filters and or acces sories intended to be used Fit testing should also
47. ien ou si l odeur ne me d range pas Les dommages physiologiques provoqu s par certains contaminants peuvent tre long terme et mettre des mois avant d apparaitre Le danger encouru peut tre masqu par une odeur inhabituelle voire agr able Une telle odeur peut ne pas vous d ranger ou provoquer de g ne chez vous mais le contaminant n en reste pas moins dangereux G Quand faut il remplacer le filtre ou la car touche Cartouche chimique La perte de protection est fr quemment d tect e lorsque l utilisateur constate une D CHIRURE Si vous constatez l un des sympt mes suivants quittez imm diatement la zone risque et retournez l air frais V rifiez votre respirateur remplacez l l ment protecteur si n cessaire et demandez l aide qui convient a Difficult respiratoire vertiges ou naus es odeur b Vertiges ou naus es c Vous d celez une odeur ou un go t de contamination d Tout autre effet physique perceptible Si vous sentez percevez ou d celez un go t inhabituel quittez la zone contamin e v rifiez votre respirateur et remplacez l l ment protecteur si n cessaire Dans certaines atmosph res la d chiru re peut tre difficile d tecter ou peut survenir trop tard pour vous permettre de quitter en toute s curit l atmosph re contamin e L usage d un respirateur purification d air n est pas appropri Toutefois dans certaines situations les cartouches chimiques p
48. iente o siga las normas ESLI para asegurarse de que los cartuchos y recipientes se sustituyen antes de que se produzcan roturas Incluye componentes el ctricos que pueden convertirse en la fuente de ignici n de atm sferas inflamables o explosivas J Eluso o mantenimiento inadecuado de este pro ducto puede causar lesiones o incluso la muerte L Siga las instrucciones de uso del fabricante para sustituir los recipientes M La selecci n el ajuste la utilizaci n y el manten imiento de todos los respiradores aprobados debe llevarse a cabo de conformidad con las normas MSHA OSHA y otras normas aplicables N Nunca sustituya modifique a ada u omita piezas Utilice nicamente las piezas de recambio exactas seg n la configuraci n especificada por el fabricante 20 O Para obtener informaci n acerca del uso y manten imiento de estos respiradores consulte las instruc ciones de uso y o los manuales de mantenimiento P El NIOSH no eval a los respiradores en cuanto a usos quir rgicos FF Deber probarse el ajuste de los respiradores antes de su uso con los modelos de mayor peso de los cartuchos recipientes filtros y o accesorios que utilizar Tambi n deber efectuarse una compro baci n del ajuste con todo el equipo de protecci n personal que se va a utilizar puesto Consulte los requisitos de las pruebas de ajuste en las instruc ciones de uso S Son de aplicaci n las instrucciones de uso especia les o cr t
49. ion Les membranes d expiration sont mont es sur une tige fixe l int rieur du couvercle de la valve de chaque c t du masque ext rieur Le couvercle doit tre remplac en m me temps que les membranes e D cliquetez le couvercle de valve du si ge de la valve Fig 16 e Extrayez les membranes Fig 17 e Comprimez les membranes neuves sur les tiges Assurez vous que les membranes s appliquent exactement sur le pourtour du si ge de la valve e Comprimez le couvercle de valve Un clic indique qu il est bien en place e Proc dez un contr le d tanch it l inspiration et l expiration D Remplacement du harnais de t te En tant que pi ce de rechange le harnais de t te peut uniquement tre command comme harnais complet e D cliquetez les supports de sangles du harnais de t te de leur fixation sur le masque Fig 18 19 e Assurez vous que les sangles ne sont pas entortill es et montez le harnais de t te neuf Vill Garantie Le fournisseur garantit a tout acheteur d un Produit et qui en est l utilisateur final que ledit Produit est exempt de vices de mati re et de fabrication l exception de l usure ordinaire durant un an compter de la date de l achat par ledit utilisateur final En outre le fournisseur garantit que le Produit est conforme aux normes NIOSH en vigueur la date de l achat La seule obligation du fournisseur et le seul recours exclusif de tout utilisateur final au titre
50. iquette d identification permanente RO9 0101 Visi re verre feuillet T01 1203 Porte pr filtre 5153 2 RO1 0604 Rondelle d essai d tanch it SR 322 pour porte pr filtre 5153 2 RO1 0303 Monture de lunettes pour verres correcteurs SR 341 TO1 1201 Couvercle de d contamination RO3 1406 Pare tincelles SR 336 TO1 2001 Casque de soudage SR 84 TO1 1212 Film protecteur SR 343 T01 1204 Film protecteur SR 353 T01 1205 Harnais de t te en caoutchouc 101 1215 Cagoule protectrice SR 64 H09 0321 Cagoule protectrice SR 345 H09 1021 Amplificateur vocal SmallTalk ST2 SR TO1 1219 S lection des l ments protecteurs Les l ments protecteurs dont l utilisation avec le res pirateur complet Sundstr m est homologu e sont les 4 cartouches chimiques et le 1 filtre particules Il existe galement un pr filtre homologu pouvant tre utilis en option avec tous les l ments protecteurs Vous pouvez identifier divers l ments protecteurs d apr s la couleur et la d signation de protection de l tiquette NIOSH du filtre de la cartouche MAGENTA P100 BLACK OV YELLOW OV SD CL HC HF WHITE CL HC SD FM GREEN AM MA P100 Filtre particules niveau d efficacit du filtre 99 97 efficace contre tous les a rosols particulaires OV Vapeur organique SD Dioxyde de soufre CL Chlore HC Chlorure d hydrog ne HF Fluorure d hydrog ne FM Formald hyde AM Ammoniac MA M thylamine Cartou
51. it Ce respirateur ne doit pas tre utilis sans une bonne compr hension de tous les composants et de leur utilit Lisez ce mode d emploi dans son int gralit et reportez vous y chaque fois que vous avez un doute Vous devez galement compl ter de fa on satisfaisante toutes les exigences de formation r glementaires et locales avant d entrer dans une atmosphere a risque Le fait de ne pas lire comprendre et suivre scrupuleusement ces consignes avant d utiliser ce produit peut entrainer des blessures voire le d c s de l utilisateur IV Configuration et guide RESPIRATEUR COMPLET Configuration fig 1 Composant Num ro de commande 1 Visi re polycarbonate RO1 1201 2 Moiti sup rieure du cadre avec vis RO1 1202 3 Harnais de t te avec sangles RO1 1203 4 Jeu de membranes RO1 1204 a Membrane d expiration 2x b Couvercle de valve 2x embrane d inspiration 3x d Tiges 2x 5 Porte pr filtre RO1 0605 6 Adaptateur de filtre SR 280 3 H09 0212 7 Joint d tanch it raccordement du filtre RO1 1205 8 Courroie de transport RO1 1206 FILTRE CARTOUCHES PREFILTRE Numero de commande Cartouche OV SR 218 6 HO2 2121 Cartouche CL HC SD FM SR 231 H02 3621 Cartouche OV SD CL HC HF SR 232 H02 3721 Cartouche AM MA SR 229 HO2 4321 Filtre P100 SR 510 HO2 1321 Prefiltre SR 221 HO2 0121 13 ACCESSOIRES Num ro de commande Serviettes de nettoyage HO9 0401 Adaptateur d essai T01 1202 Et
52. iversos elementos de protecci n por el color y el tipo de protecci n de la etiqueta del NIOSH del filtro cartucho MAGENTA P100 BLACK OV YELLOW OV SD CL HC HF WHITE CL HC SD FM GREEN AM MA P100 Filtro de part culas nivel de eficacia del 99 97 eficaz contra todo tipo de aerosoles de part culas OV Vapores org nicos SD Di xido de azufre CL Cloro HC Cloruro de hidr geno HF Fluoruro de hidr geno FM Formaldehido AM Amoniaco MA Metilamina Cartuchos para productos qu micos Todos los cartuchos para productos qu micos est n dise ados para ofrecer una protecci n respiratoria frente a determinados contaminantes Un cartucho para productos qu micos absorbe vapores y gases espec ficos en un entorno contaminado Este proceso contin a hasta que el agente absorbente se satura y permite que el t xico pase La norma OSHA exige un programa de sustituci n del cartucho para productos qu micos basado en la concentraci n del aerosol en el lugar de trabajo no confi ndose ya en la detecci n sensorial de la saturaci n para proceder a cambiar el cartucho para productos qu micos Filtros de part culas Estos filtros protegen contra las part culas Todos los filtros de part culas de Sundstr m atrapan y retienen las part culas en el elemento filtrante A medida que el contaminante retenido aumenta en el elemento fil trante tambi n aumenta la resistencia a la respiraci n Sustituya el filtro c
53. izar un purificador de aire Sin em bargo bajo ciertas condiciones pueden utilizarse los cartuchos para productos qu micos aunque deben ser sustituidos despu s de un determinado periodo de exposici n Este programa es definido por la au toridad competente y supervisado por el encargado de seguridad ADVERTENCIA Advertencia Los cartuchos para productos qu micos consumidos dejan pasar humos y vapores peligrosos y el usuario puede no percibir cambios en la resistencia al respirar Observe los procedimientos locales y todas las advertencias contenidas en el manual del usuario Filtros Los filtros limpian el aire de part culas reteniendo las s lidas y permitiendo que entre en el respirador aire respirable A medida que se va saturando el filtro con estas part culas la inhalaci n se vuelve inc moda Si nota una mayor resistencia a la inhalaci n abandone la zona contaminada y sustituya el prefiltro o en caso necesario el filtro protector En el caso de algunos filtros pueden ser tambi n de aplicaci n restricciones de uso temporal si disminuye su eficacia o si est n expuestos a t xicos espec ficos Los filtros deben sustituirse cada vez que se alcancen dichos l mites Prefiltro Este econ mico prefiltro se utiliza con un cartucho o un filtro P100 Cuando aumente la resis tencia a la respiraci n sustituya primero el prefiltro Si la resistencia no disminuye sustituya el elemento de protecci n 1 Sustituc
54. l adaptateur de filtre avec l l ment pro tecteur e Retirezle couvercle des valves d expiration et extrayez les 2 membranes e Retirez les trois membranes d inspiration e Retirez le harnais de t te e Si n cessaire d faites la visi re Reportez vous la section VII A B Nettoyage et r assemblage Un respirateur sale conf re une protection r duite Il conviendra d tablir un programme crit pour le nettoy age et la d sinfection et de s y conformer Ce programme devra inclure toutes les exigences f d rales et locales e Nettoyez le respirateur avec de l eau chaude savon neuse ou avec un autre produit de nettoyage pour respirateurs et avec une brosse douce un chiffon ne peluchant pas ou une ponge N exc dez pas 104 F 40 C N utilisez jamais de solvants pour le nettoyage e D sinfectez le respirateur Utilisez tout d sinfectant homologu ou une solution d eau de Javel a raison de 2 cuill res soupe pour 3 79 litres d eau 60 PPM de chlore ou 1 cuill re a caf de teinture d iode 50 PPM d iode dans 3 79 litres d eau Immergez le respirateur dans la solution pendant au moins 2 minutes e Rincez soigneusement e V rifiez l tat du respirateur et de toutes ses pi ces Remplacez tout composant endommag ou d fectueux e Secouez le respirateur pour enlever l exc s d eau et laissez s cher e Proc dez aun bref contr le d tanch it l inspiration et l expiration C
55. mosph re en question Les respirateurs a purification d air ne fournissent PAS d oxyg ne et NE DOIVENT PAS ETRE UTILISES dans des atmosph res contenant moins de 19 5 d oxyg ne par volume z Cerespirateur NE DOIT PAS ETRE UTILISE pour une protection contre toute substance qui peut causer une r action allergique qui contient des isocyanates ou d autres contaminants restreints ou qui manque de propri t s d avertissement ad quates Les respirateurs purification d air ne doivent pas tre utilis s dans la lutte contre les incendies de b timents NE PAS UTILISER ce respirateur pour une protection dans des atmosph res qui pr sentent ou qui peuvent pr senter un danger imm diat pour la vie ou la sant IDLH ou dans des conditions qui repr sentent une menace imm diate par la pr sence de contaminants atmosph riques susceptibles d avoir des effets n fastes diff r s sur la vie ou la sant Ce respirateur NE DOIT PAS ETRE UTILISE pour une protection contre des substances qui n ont pas des propri t s suffisantes leur permettant de signaler leur pr sence Ce respirateur n est pas homologu comme pro tection contre la projection d abrasif y compris les op rations de sablage Ce respirateur doit tre quip des filtres appropri s de purification d air des cartouches chimiques ou des combinaisons de filtre cartouche agr s par le NIOSH et convenablement install s sur le respirateur Ce respirate
56. nd can never be used as primary protection or as a substitute for the P100 It is designed to prevent nuisance particulates from reaching the protective elements This increases the life span of the primary protective element FOR USE WITH SR 500 POWERED AIR PURIFYING RESPIRATOR PAPR SR 200 Full face respirator are approved for use with SR 500 PAPR fan unit assembly Refer to the NIOSH ap proval label for approved configurations P N L27 0121 In addition to this manual the SR 500 manual P N L67 0121 must be carefully read and followed by all persons who have or will have the responsibility for using or servicing the respirator V User Training and Instructions WARNING Do not complete the user training without reading and understanding all in structions in this booklet This training section is designed for the user and their safety manager It contains the minimum information required to safely instruct users on how to don doff test and change protective elements for the Sund strom respirator This training procedure is included as a supplement to the instructions contained in the remainder of this manual Local conditions may require additional instructions Sundstr m encourages the safety professional re sponsible for the respiratory program to add all local information possible to increase worker safety and to supplement this basic text You can obtain an Instruc tors Guide from your nearest Sundstr m Distributor
57. o la salud IDLH c Los limites indicados en la aprobaci n del NIOSH de aplicaci n d Cualquier limitaci n aplicable contemplada en las normas establecidas por un organismo regulador como organismos nacionales regionales o locales con jurisdicci n sobre el usuario ADVERTENCIA Este respirador no puede eliminar todos los con taminantes de una atmosfera peligrosa Preste especial atenci n a las concentraciones maximas de uso CMU limites y otras restricciones Adem s delas concentraciones maximas de uso CMU las limitaciones y las advertencias y precauciones se aladas en el texto toda persona que vaya a utilizar el respirador de Sundstr m deber leer y comprender los siguientes puntos generales de seguridad e No utilice el respirador para pinturas que contengan isocianatos e No utilice el respirador como protecci n frente a fumigantes e Este respirador ha sido dise ado para ser utilizado nicamente por PERSONAL CUALIFICADO Y FOR MADO e La elecci n del respirador se basar en el cono cimiento completo y la evaluaci n profesional de los contaminantes y su concentraci n m xima en la atm sfera en cuesti n e Losrespiradores purificadores de aire NO suministran ox geno y NO DEBEN UTILIZARSE en atm sferas cuyo volumen de ox geno sea inferior al 19 5 Este respirador NO DEBE UTILIZARSE como protecci n frente a sustancias que puedan causar una reacci n al rgica que contengan isocianatos u
58. or para respiradores y un cepillo suave un pa o que no suelte pelusa o una esponja No supere los 40 C 104 F No limpie nunca con disolventes e Desinfecte el respirador Utilice un desinfectante homologado o una soluci n de 2 cucharadas de lej a en algo menos de 4 litros de agua 50 ppm de cloro o una cucharadita de tintura de yodo 50 ppm de yodo en algo menos de 4 litros de agua Sumerja el respirador en la soluci n durante 2 minutos como m nimo e Enjuague bien e Compruebe el estado del respirador y de todas sus piezas Sustituya cualquier pieza averiada o defec tuosa e Sacuda el respirador para eliminar toda el agua y d jelo secar e Realice una comprobaci n r pida del ajuste C Almacenamiento Almacene el respirador los filtros y los cartuchos en un lugar limpio fresco y seco alejado de la luz solar directa Periodo de almacenamiento de los elementos protec tores en sus envases no abiertos filtro de part culas 10 a os cartucho para productos qu micos 5 a os La fecha de caducidad est impresa en la etiqueta mes a o p ej mayo de 2012 VII Piezas de recambio Utilice solamente piezas originales de Sundstr m No modifique el equipo El uso de piezas piratas o cual quier modificaci n puede reducirla funci n protectora y comprometer las aprobaciones otorgadas al producto A Sustituci n de la pantalla La pantalla se monta en una ranura que rodea la apertura para la pantalla d
59. otros contaminantes restringidos y que carezcan de advertencias claras sobre sus propiedades Los respiradores purificadores de aire no deben utilizarse en la lucha estructural contra incendios NO UTILICE este respirador como protecci n en atm sferas que supongan o puedan suponer un peligro inmediato para la vida o la salud IDLH o en condiciones que supongan una amenaza inmediata por la presencia de contaminantes en el aire que probablemente tengan efectos adversos retardados sobre la vida o la salud Este respirador NO DEBE UTILIZARSE como protec ci n contra sustancias que carezcan de las debidas advertencias sobre sus propiedades Este respirador no ha sido aprobado para su uso como protecci n frente al chorreado con agentes abrasivos incluidas las operaciones de chorreado con arena Este respirador debe estar equipado con los filtros purificadores de aire cartuchos para productos qu micos o combinaciones de filtro cartucho cor respondientes aprobados por el NIOSH que deben estar correctamente instalados en el respirador El usuario debe llevar el respirador bien ajustado No utilice el respirador de Sundstr m si en la zona de contacto entre la piel y la superficie de cierre de la mascarilla se interpone barba bigote o patil las consulte la norma OSHA 29 CFR 1910 134 Ap ndice A l A 9 para obtener m s informaci n No utilice este respirador si tiene cicatrices u otras caracter sticas f sicas que impidan el aj
60. pour les exigences relatives la v rification d ajustement S Les modes d emploi sp ciaux ou essentiels et ou les restrictions d utilisation sp cifiques s appliquent Voici les avertissements et limitations du NIOSH s appliquant aux utilisations d un APR puration d air motoris A Ne pas utiliser dans une atmosph re dont la teneur en oxyg ne est inf rieure 19 5 B Ne pas utiliser dans une atmosph re pr sentant un danger imm diat pour la vie ou la sant C Ne pas d passer les concentrations d utilisation maximales tablies par les normes obligatoires F Nepasutiliserl appareil de protection respiratoire puration d air motoris si le d bit d air est inf rieur 4 pi min 115 L min pour des pi ces faciales tr s ajust es ou 6 pi min 170 L min pour les cagoules et ou casques H Suivre le calendrier de remplacement de la car touche et du bo tier filtrant ou observer l ESLI afin de garantir le remplacement des cartouches et des bo tiers filtrants avant d chirure 1 Contient des parties lectriques qui peuvent causer une source d ignition dans des atmospheres inflam mables ou explosives J Une utilisation ou un entretien inappropri de ce produit peut entrainer la mort ou des blessures L Suivre le mode d emploi fourni par le fabricant pour le remplacement des boitiers filtrants M Tous les respirateurs homologu s doivent tre s lectionn s install s utilis s et entretenus
61. re neuve dans la cannelure de sorte que les rep res indiquant le milieu co ncident Pour faciliter le montage humidifiez la cannelure l aide d une solution savonneuse ou d un liquide similaire e Replacez avec pr caution la moiti sup rieure du masque sur la visi re et assurez vous que la visi re se trouve bien dans la cannelure du masque Fig 10 e Remettez en place la moiti sup rieure du cadre en veillant ce que les rep res coincident Fig 12 e Ins rez les vis et revissez le en alternant jusqu ce que les deux moiti s du cadre soient fermement en contact Fig 8 e Proc dez un contr le d tanch it l inspiration et l expiration B Remplacement des trois membranes d inspiration Une membrane se trouve au centre du masque int rieur mont e sur une tige fixe Extrayez la membrane et montez en une neuve Fig 18 e Deux membranes sont mont es sur la face int rieure du masque int rieur une de chaque c t Les tiges de ces membranes sont amovibles et doivent tre remplac es en m me temps que les membranes e Extrayez les membranes et les tiges e Enfilez les membranes neuves sur les tiges Fig 14 e Les membranes doivent reposer sur la bride la plus large Par cons quent vous devez d abord introduire la tige avec la membrane partir de l int rieur du masque travers le si ge de la valve avec la bride la plus troite Fig 15 C Remplacement des deux membranes d expirat
62. respuesta a sus preguntas p ngase en contacto con Sundstr m Safety Inc llamando al tel fono 1 877 SUNDSTROM Ill Introducci n El respirador completo purificador de aire Sundstrom SR 200 ha sido probado y aprobado por el NIOSH para proporcionar al usuario el nivel de protecci n respiratoria certificado Proporciona protecci n ocular limitada ANSI Z87 1 2010 Elrespirador consta de una unidad exterior con pantalla de policarbonato que cubre la cara del usuario una unidad interior integrada con valvulas de inhalaci n y exhalaci n que cubre la nariz la boca y el ment n del usuario un arn s de cabeza con correas de goma y 6 puntos de sujeci n que fijan el respirador en su sitio y un adaptador del filtro para acoplar los elementos de protecci n est ndar de Sundstr m El aire inhalado pasa a la unidad interior del respirador a trav s de un elemento de protecci n y una mem brana de inhalaci n Parte del aire pasa por el interior de la pantalla para evitar que esta se empa e El aire exhalado sale de la mascarilla a trav s de dos v lvulas de exhalaci n Est n disponibles como accesorios una pantalla de vidrio laminado un adaptador de prueba y monturas de gafas para lentes correctoras Este manual est dividido en diez apartados todos de igual importancia Proporciona al usuario del respi rador la informaci n b sica para el uso inspecci n colocaci n extracci n y mantenimiento correcto del respirador de
63. rous to life or health C Do not exceed maximum use concentrations es tablished by regulatory standards H Follow established cartridge and canister change out schedules or observe ESLI to ensure that cartridges and canisters are replaced before breakthrough occurs l Contains electrical parts that may cause an ignition source in flammable or explosive atmospheres J Failure to properly use and maintain this product could result in injury or death L Follow the manufacturer s User s Instructions for changing canisters M All approved respirators shall be selected fitted used and maintained in accordance with MSHA OSHA and other applicable regulations N Never substitute modify add or omit parts Use only exact replacement parts in the configuration as specified by the manufacturer O Refer to User s Instructions and or maintenance manuals for information on use and maintenance of these respirators P NIOSH does not evaluate respirators for use as surgical masks ED FF Respirators are to be fit tested prior to use with the heaviest cartridges canisters filters and or acces sories intended to be used Fit testing should also be conducted while wearing all personal protective equipment intended to be used See User s Instruc tions for fit test requirements S Special or critical User s Instructions and or specific use limitations apply The following are NIOSH Cautions and Limitations for PAPR appl
64. sation MUC a 50 fois la limite d exposition TWA pour l agent contaminant pr sent b Concentrations d un contaminant pr sentant un danger imm diat pour la vie ou la sant 50 fois la limite d exposition TWA pour l agent contami nant pr sent IDHL c Limites pr sent es dans l homologation NIOSH applicable d Limites applicables figurant dans les normes tablies par un organisme de r glementation tel qu instances f d rales locales et d un tat dont l utilisateur rel ve AVERTISSEMENT Ce respirateur ne peut liminer tous les con taminants contenus dans une atmosph re a risque Il convient donc d tre particuli re ment attentif aux concentrations maximales d utilisation MUC aux limitations et autres restrictions Enplusdesconcentrations maximales d utilisation MUC des limitations et autres messages d avertissement et de pr caution il est important que toute personne pr voy ant utiliser le respirateur Sundstr m lise et comprenne les points de s curit suivants e Ne pas utiliser pour des peintures contenant des isocyanates e Ne pas utiliser pour une protection contre les fumi gants e Cerespirateur est con u pour tre uniquement utilis par du PERSONNEL QUALIFIE AYANT REGU UNE FORMATION 12 Le choix du respirateur doit tre bas sur une con naissance compl te des contaminants ainsi que sur leur valuation par des professionnels et leur teneur maximale dans l at
65. st the fit of the mask on your face so that it fits firmly but comfortably e Perform a fit check B Fit Check WARNING A proper fit check must be successfully completed each time the respirator is worn Failure to achieve a proper face to respi rator seal before you enter a hazardous at mosphere may result in little or no respiratory protection Install a protective element Snap the pre filter holder onto the protective element Donning the respirator Place the palm of your hand lightly over the hole on the pre filter holder to make it tight Fig 20 NOTE Do not push so hard that the respirator s shape is affected Inhale gently the respirator should pull inward on the face Hold your breath the respirator should remain col lapsed on the face Remove the palm of your hand from the pre filter holder e Breathe normally If any leakage is detected check the inahalation and exhalation valves or adjust the straps of head harness Repeat the fit check until there is no leakage C Doffing e Slacken the four elastic straps in pairs by moving the strap holder forward The two inelastic straps need not be released Fig 7 e Pull the head harness forward over your head and remove the respirator e Decontaminate clean and store respirator as required SR500 PAPR application For donning and doffing Instructions refer to the SR 500 PAPR User s Instructions P N L67 0121 VI Cleaning and storage A Disassem
66. str m respirator This manual provides only the basic elements of a complete respirator program Awell designed respirator program also includes fit testing proper documentation and active management by your local safety profes sional All regulations and recommendations found in OSHA documents especially 29 CFR 1910 134 EPA Standards American National Standards Institutes ANSI Standard 288 2 and all applicable state pro vincial and local regulations shall be referenced in the complete safety program This respirator should not be used without thorough understanding of all the components and their purpose Read this entire booklet carefully and refer to it wherever aquestion arises You must also satisfactorily complete all regulatory and local training requirements before entering a hazardous atmosphere Failure to read understand and carefully follow these instructions prior to using this product may result in personal injury or death IV Configuration and selection guide FULL FACE RESPIRATOR Configuration fig 1 Component Order Number 1 Polycarbonate visor R01 1201 2 Upper frame half with screws R01 1202 3 Head harness assembly R01 1203 4 Set of membranes R01 1204 a Exhalation membranes two b Valve covers two c Inhalation membranes three d Dowels two 5 Pre filter holder RO1 0605 6 Filter adapter SR 280 3 H09 0212 7 Gasket for filter connection RO1 1205 8 Carry Strap RO1 1206 FILTER CART
67. tain conditions the chemical cartridges can be used but must be changed after a specific exposure time This schedule is set by a competent authority and controlled by your safety professional WARNING Warning An exhausted chemical cartridge will allow hazardous fumes or vapors to pass through to the user who may not notice any change in breathing resistance Follow local procedures and all warnings contained in the users manual Filters Filters clean the air of particles by capturing the solid particles and allowing breathable air to enter the respirator As the filter loads up with these particulates inhalation becomes uncomfortable When you detect increased inhalation resistance leave the contaminated area and change the pre filter or if necessary the protective filter Time use restrictions may also apply to some filters when efficiency declines or when they are exposed to specific contaminants Filters must be replaced every time these limits are reached Pre filter This inexpensive nuisance pre filter is used with acartridge or P100 filter When breathing resistance increases change the pre filter first If the resistance does not drop change the protective element 1 Changing the protective elements A Installation removal Select the appropriate protection Remain in a safe atmosphere and select the proper cartridge and ap propriate filter B Assembling the cartridge P100 filter combi nation Fig 2
68. th year e g May 2012 VII Spare parts Use only genuine Sundstr m parts Dont modify the equipment The use of pirate parts or any modifications may reduce the protective function and will compromise the approvals granted to the product A To change the visor The visor is mounted in a groove running around the visor opening of the outer mask and is held in place by one upper and one lower frame half e Use a 2 5 mm Allen key to remove the two screws holding the frame halves together Fig 8 e Carefully remove the upper frame half Fig 9 e Carefully pry the top part of the mask off the visor and remove the visor from the lower groove Fig 10 11 Take this opportunity to clean the groove if necessary e Markings are made to show the centres of the visor frame halves and mask Fig 12 Press the new visor into the groove making sure that the centre markings are in line To make assembly easier coat the slot with a soap solution or similar liquid e Carefully prise the top half of the facepiece over the visor and make sure that the visor is in the groove in the facepiece Fig 10 e Prise the upper frame half making sure that the centre markings are in line Fig 12 e Fit the screws and tighten them alternately until the two halves of the frame are firmly in contact Fig 8 e Perform a fit check B To change the inhalation membranes three e One membrane is in the centre of the inner mask on a fixed dow
69. the proper application selection or maintenance of this equipment consult your supervisor safety profes sional or local occupational health organization Do not enter a suspected hazardous area For answers to your questions contact Sundstrom Safety Inc at 1 877 SUNDSTROM Ill Introduction The Sundstr m SR 200 Full face Air purifying Respira tor APR has been tested and approved by NIOSH to provide the approved level of respiratory protection to a user Provides limited eye protection ANSI Z87 1 2010 The respirator consists of an outer mask with polycar bonate visor that covers the user s face an integrated inner mask with inhalation and exhalation valves that covers the user s nose mouth and chin a rubber strap head harness with 6 mounting points that hold the respirator in place and a filter adapter for connecting standard Sundstr m protective elements The inhaled air flows through a protective element and inhalation membrane into the inner mask Part of the air flows past the inside of the visor in order to prevent misting The exhaled air is discharged from the face piece through two exhalation valves A laminated glass visor a test adapter and spectacle frames for fitting corrective lenses are available as accessories This manual is divided into ten sections of equal importance It will provide a respirator user with the basic information to properly use inspect don doff and perform maintenance for the Sund
70. tiene la obligaci n de informarle sobre qu filtro cartucho o combinaci n le proporcionar suficiente protecci n frente a los peligros existentes en su lugar de trabajo Puede identificar los 10 elementos de protecci n por el color de la etiqueta del NIOSH MORADO Particulas polvo vapores y humos NEGRO Vapores organicos AMARILLO Vapores organicos didxido de azufre cloro cloruro de hidr geno fluoruro de hidr geno BLANCO Cloro cloruro de hidr geno didxido de azufre form aldehido VERDE Amoniaco y metilamina En las etiquetas de aprobaci n del NIOSH DHHS de cada producto se indican las limitaciones y requisitos Todas las etiquetas del NIOSH DHHS actuales se encuentran impresas en la caja de los respiradores en una hoja titulada Apartado IX ETIQUETAS DEL NIOSH DHHS de este manual El filtro P100 de Sundstr m se puede combinar con todos los cartuchos para productos quimicos para brindar al usuario una protecci n combinada contra vapores gases y particulas E Qu funci n tiene el prefiltro El prefiltro de Sundstr m solamente puede utilizarse con un cartucho o un filtro P100 para disminuir los polvos molestos Este prolonga la vida util del elemento de protecci n atrapando las part culas grandes e impidiendo as la saturaci n prematura de los elementos de protecci n primarios El prefiltro no es un elemento de protecci n ADVERTENCIA EI prefiltro de Sundstr m es un filtro del
71. u et de la preuve d achat Votre distributeur fera parvenir le Produit au fournisseur pour analyser la validit de votre r clamation IX Illustrations page 29 X tiquettes du NIOSH DHHS Voir encarts 19 Mascarilla completa SR 200 ndice Limitaciones de la aprobaci n del NIOSH II Limitaciones generales de uso del respirador lll Introducci n IV Gu a de configuraci n y selecci n V Formaci n e instrucciones del usuario 1 Sustituci n de los elementos de protecci n 2 Inspecci n previa al uso 3 Colocaci n comprobaci n del ajuste y extracci n VI Limpieza y almacenamiento VII Piezas de recambio VIII Garant a IX Ilustraciones XI Etiquetas del NIOSH DHHS p ginas adjuntas a este folleto l Limitaciones de la aprobaci n Nota las precauciones y limitaciones indi cadas no afectan a todas las aplicaciones Consulte la matriz adjunta de la etiqueta de aprobaci n indique el n mero de pieza para verificar cu les son las precauciones y limitaciones pertinentes Aplicaci n del respirador purificador de aire APR con cartucho para productos qu micos A Nose debe utilizar en atm sferas con un contenido de ox geno inferior al 19 5 B No se debe utilizar en atm sferas que representen un peligro inmediato para la vida o la salud C No supere las concentraciones m ximas de uso contempladas en las normas reglamentarias H Respete los calendarios de sustituci n del car tucho y el recip
72. uando note que la respiraci n se hace m s dif cil El filtro P100 tiene una eficacia del 99 97 contra los aerosoles de part culas Sundstr m Safety ha llevado a cabo ensayos de degra daci n de su filtro P100 Los resultados de los ensayos demuestran que este filtro no se degrada ni siquiera tras un largo periodo de exposici n a contaminantes a base de aceite Combinaci n de los elementos de protecci n Un cartucho para productos qu micos adecuado puede combinarse con el filtro P100 para ofrecer protecci n frente a una combinaci n de determinados vapores gases y part culas Prefiltro El prefiltro de Sundstr m no es un elemento de protec ci n y nunca debe usarse como protecci n primaria o como sustituto del filtro P100 Est dise ado para evitar que las part culas molestas lleguen alos elementos de protecci n De este modo se prolonga la vida ltil del elemento de protecci n primario PARA UTILIZAR CON EL RESPIRADOR PURIFICADOR DE AIRE MOTORIZADO PAPR SR 500 El respirador completo SR 200 est aprobado para su uso con el m dulo de ventilador para PAPR SR 500 Consulte las configuraciones aprobadas P N L27 0121 en la etiqueta de aprobaci n del NIOSH Todas las personas actual o posteriormente encargadas de utilizar o realizar el mantenimiento de este respirador deber n leer detenidamente y observar adem s de este manual el manual P N L67 0121 del SR 500 V Formaci n e instrucciones del usuario A
73. ur de filtre avec filet standard permettant de raccorder un filtre standard Sundstr m Lair inspir p n tre dans le masque int rieur en traversant l l ment protecteur et les membranes d inspiration Une partie de l air passe sur la face int ri eure de la visi re pour emp cher la formation de bu e L air expir est vacu du masque par l interm diaire de deux valves d expiration Des accessoires tels qu une visi re de verre feuillet un adaptateur d essai et des montures de lunettes pour l insertion de verres correcteurs sont disponibles Le pr sent manuel est divis en dix chapitres d gale importance 1 fournira l utilisateur du respirateur les informations de base lui permettant d utiliser d inspecter de mettre en place de retirer et d entretenir convenablement un respirateur Sundstr m Ce manuel ne fournit que les l ments de base du programme complet du respirateur Un programme de respirateur bien con u comprend galement le contr le de l tanch it la documentation appropri e et la gestion active assur e par votre responsable local de la s curit Toutes les r gles et recommandations pr sent es dans les documents de l OSHA particu li rement la norme 29 CFR 1910 134 les normes de l EPA la norme 288 2 de l American National Standards Institutes ANSI et tous les r glements de l tat pro vinciaux et locaux doivent tre cit s en r f rence dans le programme complet de s cur
74. ur doit s ajuster convenablement au vis age de celui qui le porte Ne pas utiliser le respirateur Sundstr m si vous portez une barbe de plusieurs jours une barbe naissante la barbe la moustache oudes favoris quiemp chent une parfaite tanch it du demi masque et qui se situent sur la surface du respirateur voir la norme 29 CFR 1910 134 Annexe A I A 9 de OSHA pour de plus amples pr cisions Ne pas utiliser ce respirateur si vous avez des cicatri ces ou d autres caract ristiques physiques pouvant affecter l tanch it du respirateur Lisez toujours les tiquettes d approbation des cartouches et des filtres avant utilisation Les l ments destin s la purification de l air et con us uniquement pour une protection contre les particules en suspension dans l air NE DOIVENT PAS ETRE UTILIS ES pour une protection contre les vapeurs ou les gaz Les l ments destin s la purification de l air et con us uniquement pour une protection contre les vapeurs et les gaz NE DOIVENT PAS ETRE UTILIS ES pour une protection contre les particules en suspension dans l air e Ladur e de vie utile des l ments destin s la purifi cation de l air varie en fonction de la concentration et de la nature du des contaminant s et de l activit de celui qui porte le respirateur Remplacez l l ment de purification de l air lorsque vous d tectez tout indice de d t rioration ou de perte d efficacit ou lorsque l organisme comp
75. uste correcto del mismo Antes de usuarlo lea siempre las etiquetas de aprobaci n del cartucho y el filtro Los productos de purificaci n del aire dise ados exclusivamente para proteger frente a las part culas en suspensi n en el aire NO DEBEN UTILIZARSE para protegerse contra vapores o gases Los productos de purificaci n del aire dise ados exclusivamente para proteger frente a vapores o gases NO DEBEN UTILIZARSE para protegerse contra las part culas en suspensi n en el aire La vida til de los productos de purificaci n del aire var a en funci n de la concentraci n y el tipo de contaminante s y de la actividad del usuario Sustituya los productos de purificaci n del aire en cuanto detecte cualquier indicio de aver a o p rdida de eficacia o bien cuando as lo establezca una autoridad competente Ante cualquiera de las se ales de peligro siguientes abandone la zona peligrosa de inmediato Vuelva al aire puro y solicite asistencia 21 a Dificultad para respirar b Mareos o n useas c Siente el olor o el sabor de los contaminantes d Cualquier otra molestia f sica que note Si la autoridad competente no ha especificado la pro tecci n adecuada o si tiene dudas sobre la aplicaci n selecci n o mantenimiento correctos de este equipo consulte con su supervisor con el encargado de se guridad o con el organismo local de salud laboral No entre en una zona si se sospecha que es peligrosa Para obtener una
76. will wear it Do not use the Sundstr m respirator if you have any hair growth between the skin and facepiece sealing surface such as stubble beard growth beard moustache or sideburns which cross the respirator surface see OSHA standard 29 CFR 1910 134 Appendix A A 9 for further clarification Do not use this respirator if scars or other physical characteristics may interfere with a proper fit of the respirator e Always read cartridge and filter approval labels prior to use Air purifying elements designed only for protection against airborne particles MUST NOT BE USED for protection against vapors or gases Air purifying elements designed only for protection against vapors or gases MUST NOT BE USED for protection against airborne particulates The useful service life of the air purifying elements will vary with the concentration and nature of the contaminant s and the activity of the respirator wearer Replace the air purifying elements when you detect any indication of damage or loss of effective ness or when instructed by competent authority e If you experience any one of the following danger signals leave the hazardous area immediately Return to fresh air and seek assistance a Breathing difficulty b Dizziness or nausea c You smell or taste the contaminants d Any other noticeable physical problem If the appropriate protection is not specified by a com petent authority or should you feel uncertain about