1. RENEGADE THOMAS 40 er res 1419 ILLINOIS AVE SHEBOYGAN WI 53081 USA 1 800 558 7721 www thomasairpac com OWNER S MANUAL and OPERATING INSTRUCTIONS for Model T 200ST Portable Perma Lube Heavy Duty Air Compressor WOB L PISTON COMPRESSOR 2650 E 40th Ave e Denver CO 80205 Phone 303 320 4764 Fax 303 322 7242 1 800 833 7958 www geotechenv com WARNING Read and understand the information in this owner s manual before operating air compressor Part No 642431 Rev P 02 07 2006 Gardner Denver Thomas Inc Printed in U S A All Rights Reserved TABLE OF CONTENTS Page General Description 1 PNG AUN cinta in ane 1 A o 2 AP EA 3 Operating Instructions sssssmmsmsnse 4 MAMtenaNCO siones de ensems 6 Spanish Language Instructions 7 Exploded View amp Parts List 10 French Language Instructions 15 Compressor Troubleshooting 21 Limited Warranty it it elles 22 GENERAL DESCRIPTION The Renegade model T 200ST is an electrically powered air compressor with a thermally protected motor mounted to two 2 gallon air storage tanks Tank pressure is regulated by a combination of a pressure switch and a safety valve The pressure switch will turn the compressor on when tank pressure drops below 110 PSIG and turn the compressor off when tank pressure reaches 135 PSIG The safety valve prevents tank pressure from exceeding 165 PSIG SPECIFICATIONS Voltage
2. il se peut que le compresseur ait besoin de plus de temps pour refroidir Si le protecteur de surchauffe arr te fr quemment le moteur cela peut venir d un faible voltage Les signes habituels d un faible voltage sont les suivants 1 Le motteur manque de puissance ou ne peut atteindre la vitesse normale 2 Les fusibles ou le disjoncteur sautent lorsque le compresseur d marre 3 Les lumi res des lampes baissent ou restent faibles lorsque le compresseur d marre 4 D autres appareils moteur ne marchent pas correctement 5 Trop d appareils a moteur sont sur le m me circuit lectrique 18 COMPRESSEUR DE PRESSION Le compresseur fonctionne par un leveir en action auto ferm au dessus de la c t de commutateur de pression En tournant le levier la position horizontal e le compresseur d marrera et cessera automatiquement l interieur de la position de commutateur de pression Le commutateur de pression est fait dans la fabrique et ajust pour mettre en marche le compresseur quand la pression du r servoir tombe au dessous de 110 PSIG et de cesser quand la pression de r servoir atteind jusqu a 135 PSIG Pour fermer le compresseur tourner le levier dans sens des aguilles d une montre a la position verticale NE FERMER JAMAIS LE COMPRESSEUR PAR ENLEVEMENT LE TAMPON ELECTRIQUE Le levier de en action ferme fonctionne la soupape qui soulage la pression de compresseur Si le levier est laiss en actio
3. a imants ic iia seventies 115V 60Hz FUSE REQUIFEMEN S cio ai 15A LOW Amp Draw ascii adan iia anda AAA aida asta 13A Safety Valve Setting 165 PSIG 1138 KPa Air Displacement naiaiae 8 0 CFM 227 LPM Air Delivery EEN 5 5 CFM 50 PSI 156 LPM 345 KPa Geet EEN 4 6 CFM 100 PSI 130 LPM 689 5 KPa Automatic Control Starts 110 PSIG 758 KPa dant dd a A dida Stops 135 PSIG 931 KPa IS vU BEE 6 ft 1 83 M Tank SIZE siesccccicccissiecadecesindecsesust ecndeevesidedccndsedvvsedseuidentednade 2 Q 3 5 Gal ea 7 Gal Shipping Weight EE 71 Ibs Sound LOVE eT T 75 dB PSI Pounds Per Square Inch CFM Cubic Feet Per Minute KPa Kilopascals LPM Liters Per Minute APPLICATION Ideal as primary or secondary air source for almost any operation the Renegade T 200ST is particularly suitable for shops garages and factories where repetitive use demands high reliability The T 200ST will operate 6 Finish Nail Guns 8 Brad Nail Guns 1 2 Sheathing Guns Visit www thomasairpac com for more information Framing Guns 1 3 1 3 Roofing Guns SAFETY FIRST if not follovved could endanger the personal safety and or property of yourself and others Read and understand the information in this owner s manual and the engine owners manual before operating This symbol points out i
4. connected to the grounding pin Check with a qualified electrician ifthe grounding instructions are not completely understood or if unsure unit is properly grounded Do not modify the plug that has been provided If it does not fit the available outlet the correct grounded outlet must be installed by a qualified electrician OPERATION Safety Valve The safety valve is designed to prevent pressure in the storage tank from exceeding 165 PSIG WARNING Do not tamper with or attempt to eliminate the safety valve Thermal Overload Protector The compressor motor is equipped vvith a thermal overload protector If the motor should overheat the overload protector will shut the motor off If this occurs turn the on off lever to the off position and allow motor to cool for ap proximately 5 minutes NOTE Tank pressure must be below 110 PSIG for the compressor to start Restart the compressor by moving on off lever to the on position If compressor fails to start check for blown fuses the compressor may require more time to cool If the overload protector shuts down the motor frequently it could be due to low voltage Common signs of low voltage are 1 Motor does not get up to power or speed 2 Fuses or circuit breaker activate when starting compressor 3 Lights dim or remain dim when compressor is started 4 Other motor operated appliances fail to operate property 5 Too many motor operated appliances on same circuit Pressure S
5. le filtre est bouch ou endommag remplacez le ATTENTIONI Ne jamais nettoyer le filtre air avec un liquide ou un dissolvant inflammable Des gaz explosibles peuvent s accumuler dans les r servoirs et provoquer une explosion pouvant causer de tr s graves blessures ou m me la mort A ATTENTIONI Ne faites pas marcher le compresseur sans filtre air R servoirs d accumulation Les r servoirs d accumulation doivent tre purg s apres chaque utilisation ou toutes les quatre heures de marche pour emp cher une accumulation de condensation et la corrosion de l int rieur des r servoirs Pour purger les r servoirs 4 ouvrez lentement et soigneusement les raccords de purge penchez l appareil du c t des raccords et laissez l eau sortir robinet REMARQUE Quand vous purgez les r servoirs regardez s il se trouve des d bris particules de rouille Si oui contactez votre concessionnaire pour un ventuel remplacement des r servoirs A ATTENTION Ne faites pas de soudures sur les r servoirs de ces compresseurs Des soudures sur les r servoirs de ces compresseurs air pourraient s rieusement affaiblir la r sistance des r servoirs et cr er des conditions tr s dangereuses N importe quelle soudure sur un r servoir annulera la garantie Si des travaux sous garantie ou des r parations sont n cessaires addressez vous un fournisseur r parateur
6. Cover Large 1 604465 Switch Motor 1 626754 Key Square 3 16 x 45 1 607810 Ecc Brg Rod amp Sleeve Ass y 1 Key Part No Description Qty 9 625008 Set Screw 5 16 18 10 626183 Piston Cup 11 626190 Cup Retainer 12 625170 Screw 1 4x20 x 7 8 Flat Head 13 618193 Cylinder Sleeve 14 662404 Deflector Cover 15 625192 Screw 10 24 x 5 Pan Head 16 638744 Fan 17 626563 Washer 13 18 626509 Lockwasher 10 19 662405 Front Cover 623075 O ring 662826 Valve Plate Acrylic Coat 662331 Flapper Valve 617497 Restraint 625278 Screw 10 32x3 8 623082 O Ring Head Gasket 662501 Head 625646 Screw 10 24x7 8 625171 Head Screw 664142 Filter Element 664141 Filter Cover 626377 Wire Clip alalaolaini i pm wm Ja fa a jo a em a ft 11 OPERACION VALVULA DE SEGURIDAD La v lvula de seguridad ha sido dise ada para prevenir que la presi n en los tanques de almacenamiento exceda 140 PSIG PRECAUCION No altere ni trate de eliminar la v lvulade seguridad PROTECTOR TERMICO PARA SOBRECARGA El motor del compresor esta equipado con un protector t rmico para sobrecarga Si el motor se llegara a recalentar este protector apagar el motor Si esto ocurre apague la unidad y deje que el motor se enfrie aproximada
7. ISE DE al passe AVEC PRISE DE TERRE BOITE FICHE DE TERRE DANGER Une mauvais installation de la fiche de terre peut causer une lectrocution S il faut r parer ou changer le fil lectrique ne raccordez pas le fil de terre n importe quelle fiche plate de terre 17 Le fil recouvert d un isolant vert avec ou sans raies jaunes est le fil de terre Faites v rifier l installation par un lectricien qualifi si vouscomprenez pas enti rement les instructions concernant la mise la terre ou si vous n tes pas s r que l appareil soit correctement mis a la terre FONCTIONNEMENT Soupape de s ret La soupape de s ret est concue pour que la pression qui se trouve dans les r servoirs d accumulation n exc de pas 165 PSIG AATTENTION N essayez pas de modifier ou de supprimer la soupape de s ret Protecteur de surchauffe Le moteur du compresseur est quip d un protecteur de surchauffe Si le moteur vient a surchauffer le protecteur de surchauffe arr tera le moteur Si cela arrive mettez le levier marche arr t sur la position arr t et laissez le moteur se refroidir pendant environ cing minutes REMARQUE La pression du r servoir doit tre inf rieure a 110 PSIG pour que le compresseur puisse red marrer Red marrez le compresseur en mettant le levier marche arr t la position marche Si le compresseur ne d marre pas v rifiez les fusibles pour voir s ils n ont pas saut
8. Loose or Damaged Contact Service Center Drain Air from Tank s through Drain Valves Ensure Air Lines are Free of Moisture Inspect Gauge Contact Service Center Adjust Regulator to Required Pressure Inspect Regulator Contact Service Center These procedures require special fixtures tools or asssembly techniques available only through a Service Center For service contact the dealer from whom you purchased the compressor To order parts visit our website www thomasairpac com or call our Customer Service Center at 1 800 558 7721 21 Limited Warranty The Gardner Denver Thomas Inc Compressor is warranted to you the original purchaser for a period of one year from date of original purchase to be free from defects in material and workmanship If during the specified warranty period you believe the purchased product or any part thereof has such a defect you must return the product or part during such period with proof of purchase and at your cost to the nearest authorized service center consult the list of service centers enclosed with the product for repair or replacement of the defective part If you do not know the location of the nearest service center contact Gardner Denver Thomas Inc at the address below for instructions If the product or part is found to have been defective in material or workmanship it will be repaired or replaced as deemed necessary by the repair center free of charge and returned t
9. OM UNUSABLE MACHINERY OR FACILITY DOWNTIME HOWSOEVER CAUSED AND EVEN IF THE POTENTIAL FOR SUCH DAMAGES WAS DISCLOSED AND OR KNOWN The remedy provided in this Limited Warranty for defective product is purchaser s sole and exclusive remedy subject to your state law Further this Warranty gives you specific legal rights and you may also have other rights which may vary from state to state If you believe warranty service is needed contact your nearest authorized service center If one does not exist in your area please contact the manufacturer Thomas Products Division of Gardner Denver Thomas Inc C O Customer Service THOMAS Sheboygan Wisconsin 53082 Phone 800 558 7721 A Gardner Denver Product Fax 920 451 6307 www thomasairpac com 22
10. S 100PIES 150 PIES CALIBRE 12 12 10 8 NOTA El tama o del cable aurnenta conforme el calibre disminuye INSTRUCCIONES PARA LA CONEXION A TIERRA PELIGRO Una Conexi n a tierra incorrecta puede dar como resultado un choque electrico En caso de un corto circuito la conexi n a tierra disminuye el riesgo de un choque ya que provee un cable de escape para la corriente el ctrica El compresor de aire debe tener una conexi n a tierra El cable del compresor de aire viene listo con un cable con conexi n a tierre y un enchufe con conexi n a tierra apropiado El enchufe debe ser usado con un tomacorriente que al ser instalado haya seguido las leyes y ordenanzas locales para efectos de conexiones a tierra El tomacorriente debe tener la misma configuraci n del enchufe No use un adaptador No le haga modificaciones al enchufe que se provee Si no encaja bien en el tomacorriente existente un electricista profesional debe instalar el tomacorriente correspondiente Inspeccione el enchufle y el cable cada vez que use la unidad No use el compresor si presenta sefiales de averias TOMACORRIENTE CONECTADO A TIERRA TOMACORRIENTE CONECTADO A TIERRA ESTUCHE CLAVIJA CO NECTADAA TIERRA A PELIGRO Si la instalaci n del enchufle conectado a tierra es hecha incorrectamente puede producirse un choque el ctrico Si necesita reparar o reemplazar el cable o el enchufe no conecte el cable a tierra a ninguno de los dos gajos plano
11. S ACCESSOIRES PREVUS POUR UNE PRESSION INFERIEUREA 9 5kg cm2 135 psi Y COMPRIS MAIS NON LIMITE AUX PISTOLETS A PEINTURE TUYAUX ET RACCORDS DES TUYAUX Si des r parations ou un entretien en cours de garantie s av rent n cessaires addressez vous au service entretien agr le plus proche S il n y en a pas addressez vous l usine Des r parations ou un d montage non permis annuleront la garantie usine UTILISATION Id al comme source d air primaire ou secondaire pour pratiquement toute op ration Particuli rement pratique pour boutiques et garages ainsi que pour les usines o un usage r p t requiert un appareil de haute fiabilit 15 ENTRETIEN GENERAL ET SERVICE Lisez et comprenez l information dans le manuel de ce propri taire avant d op rer le compresseur CARACTERISTIOUES Voltage E 115V 60Hz FUSIDIOS ici io Aci 15A R glage de la soupape de S ret 165 PSiG 1138 KPa Volume Galt d place niet 8 0 CFM 227 LPM D bit KI 5 5 CFM 50 PSI 156 LPM 345 KPa E pcia ds codi 4 6 CPM a 100 PSI 130 LPM a 689 5 KPa Amp res quand l appareil est sous pression ooooniccnccnnncoccccnnncnnncccnnnnnnn cnn 13 AMP Contr le automatique D marre 110 PSIG 758 KPa SR ta S arr te 135 PSIG 931 KPa Contenance des r servoirs vieil 4 gallons PoldS cuca tA aii a ae 71 livres lee EE 6 pieds 1 83m PSI Livres par pouce carr CFM Pied
12. ance au moteur utilisez des tuyaux suppl mentaires au lieu d une rallonge lectrique Si une rallonge doit tre utilis e n utilisez qu une rallonge lectrique trois fils avec une fiche troisbroches prise de terre et une prise trois trous pour recevoir la fiche qui se trouve sur le compresseur d air Assurez vous que la rallonge est en bon tat CALIBRE MINIMUM DES RALLONGES ELECTRIQUES DE RALLONGE 25PIEDS 50PIEDS 100 PIEDS 150 PIEDS CALIBRE 12 12 10 8 REMARQUE La grosseur du fil augmente lorsque ie chiffre du cali bre diminue Instructions de mise la terre DANGER Une mauvaise mise ala terre peut causer des lectrocutions En cas de court circuit la mise la terre r duit le risque d lectrocution en permettant au courrant de s chapper Le compresseur d air doit tre mis a la terre Le fil lectrique du compresseur d air est quip d un fil de terre et d une fiche de terre appropries La fiche doit tre utilis e avec une prise install e et mise a la terre selon les r glements et les ordonnances locales La prise doit avoir le m me configuration que la fiche Ne pas utiliser d adaptateur Ne modifiez pas la fiche qui vous est fournie Si celle ci ne s adapte pas a la prise disponible il faut faire installer la prise correcte par un lectricien Inspectez la fiche et ie fit lectrique avant chaque utilisation N utilisez pas le compresseur d air si ces elements sont endommag s PRISE AVEC PR
13. ar en el suministro de aire contaminado al equipo correspondiente 5 El flujo de aire comprimido no debe dirigirse a ninguna persona porque puede provocar lesiones graves No permita que se acerquen los ni os UTILICE PROTECTORES PARA LOS OJOS 6 Todos los compresores de aire generan calor aun bajo condiciones de operacion normales Para evitar quemaduras graves no toque el cabeza ni los componentes del escape del compresor durante la operaci n o inmediatamente despu s de ella 7 Cuando la unidad no est en uso enrolle el cablealrededor del compresor y gu rdelo en un lugar seco No maltrate el cord n 8 ANTES DEL SERVICIO LA LIMPIEZA O EL DESMONTAJE DE CUALQUIER PIEZA APAGUE LA UNIDAD Y ALIVIE LA PRESION 9 ESTE SISTEMA PUEDE PRODUCIR HASTA 9 5 kg cm 135 psi PARA EVITAR RUPTURAS DE COMPONENTES Y LESIONES CORPORALES NO OPERE LA UNIDAD CON ACCESORIOS POR EJEMPLO PISTOLAS DE PULVERIZACION MANGUERAS Y CONECTORES DE MANGU S CUYA PRESION NOMINAL DE TRABAJO SEA INFERIOR A 9 5 kg cm 135 psi Si se requieren reparaciones o servicio de garantia p ngase en contacto con el centro de servicio autorizado m s cercano Si no dispone de un centro p ngase en contacto con la f brica Las reparaciones o el desmontaje de la unidad sin autorizaci n anular n la garant a de f brica APLICACIONES Este compresor es ideal como unidad neum tica primaria o secundaria para pr cticamente cualquier tipo de operaci n Especialme
14. autoris S il n y en a paspr s de chez vous contactez l usine Le d montage nonautoris de l appareil annulera la garantie 20 ELECTRIC COMPRESSOR TROUBLESHOOTING The following guide has been compiled to assist the consumer in identifying problems that may be encountered with electric compressors Please inspect for possible causes and contact an authorized service center when necessary SYMPTOM POSSIBLE CAUSE CORRECTIVE ACTION Motor Won t Start Compressor Won t Restart Low Air Output Compressor Won t Shut Off Water in Air Lines or Tools Low Pressure to Tools No Power to Compressor Switch Lever in Off Position Faulty Start Relay Faulty Start Capacitor Check Valve Leaks Low Voltage to compressor Pressure Switch Hanging Up Leak At Fitting s Broken Valve Flapper Debris in Valves Faulty Head Gasket Faulty Valve Plate Gasket Worn Piston Cup Leak At Fitting s Broken Valve Flapper Debris in Valves Faulty Head Gasket Faulty Valve Plate Gasket Worn Piston Cup Relief Valve Leaking Tank Not Drained Regularly Damaged Gauge on Regulator Regulator Not Adjusted Properly Faulty Regulator Check Circuit Breaker or Fuse Move Switch Lever to On Position 4 Inspect Check Valve Contact Service Center Connect Unit to Sufficient Voltage Source Inspect Pressure Switch Contact Service Center Inspect Fittings If Loose or Damaged Contact Service Center Inspect Fittings If
15. examiner le tuyau la fiche et le fil lectrique pour rep re tous signes de d terioration Ne pas utiliser l appareil en cas de d faut de fonctionnement ou de mat riel Addressez vous au service entretien le plus proche pour obtenir des pi ces de rechange Ne jamais utiliser un appareil d fectueux 3 Ne pas modifier la pression de la soupape de s ret elle a t r gl e en usine Tout autre r glage pourrait entr iner un risque de blessure grave 4 Ce compresseur d air ne n cessite aucune lubrification Le graissage des pi ces risque de polluer l air comprim alimentant les accessoires pneumatiques 5 L air comprim ne doit jamais tre point sur une personne car il peut entr iner des blessures graves Eloigner les enfants de l endroit de travail PORTER DES LUNETTES DE PROTECTION 6 Tous les compresseurs d air produisent de la chaleur m me dans des conditions de fonctionnement normales Afin d eviter tes br lures ne jamais toucher le compresseur d air pendant ou tout de suite apr s utilisation 7 Quand il n est pas utilis enrouler le fil lectrique autour du compresseur et stocker dans un endroit sec Faire attention a ne pas endommager le fil lectrique 8 AVANT D UTILISER DE NETTOYER OU DE RETIRER TOUT ACCESSOIRE DEBRANCHER L APPAREIL ET REDUIRE LA PRESSION 9 CE SYSTEME PEUT PRODUIRE 9 5 kg cm 135 psi POUR EVITER TOUTE RUPTURE POUVANT ENTRAINER DES BLESSURES NE PAS UTILISER CETTE POMPE AVEC DE
16. horized repairs or teardown of the unit will void the factory warranty 2 SET UP Location of Air Compressor Operate air compressor in a clean dry and vvell ventilated area The air filter must be kept clear of obstructions which could reduce air flow to the compressor The air compressor should be located at least 12 away from walls or other obstructions that could interfere with the flow of air 1 Remove the air compressor from the box 2 Close the drain valves one on each tank pressure at maximum counter clockwise position A Pull out yellow cap B Turn to set pressure clockwise to increase C Push cap in to lock setting 4 Turn on auto off lever on the pressure switch to the OFF position 5 Attach air hose to the regulator outlet 6 Plug the power cord into a grounded outlet or approved extension cord See Grounding Instruction section Turn the on auto off lever on the pressure switch to the ON position 7 Turn regulator knob clockwise to set the pressure required for your application Extension Cords To avoid voltage drop and power loss to motor use additional hose instead of an extension cord If an extension cord must be used use only a 3 wire extension cord equipped with a 3 blade grounding plug and a 3 slot receptacle that will accept the plug on the compressor Be sure to use an extension cord heavy enough to carry the current your product wil
17. is in water contact your dealer for possible tank replacement The appearance of rust inside the tank will compromise its ability to hold pressure and can cause bursting A WARNING Do not weld on the air tank of this compressor Welding on the air compressor tank can severely impair tank strength and cause an extremely hazardous condition Welding on the tank in any manner will void the warranty If warranty service or repairs are needed contact your nearest authorized servicing dealer If one does not exist contact the factory Unauthorized teardown of the unit will void the factory warranty 6 REGLAS PARA UNA OPERACION SEGURA PRECAUCION Antes de operar el compressor de aire lea este manual del propietario y aseg rese de comprender la informaci n aqui contenida 1 El compresor debe ubicarse en una zona seca timpia y bien ventilada 2 Antes del uso inspeccione la manguera el tap n y elcable para asegurarse de que est n en buenas condiciones En caso contrario no use el compresor Las unidades dafiadas nunca deben operarse Para la obtenci n de piezas de reemplazo consulte con su centro de servicio mas pr ximo 3 El ajuste de la v lvula de alivio de seguridad ha sido fijado en la f brica No lo altere Los ajustes de esta v lvula peudan provocar lesiones graves 4 Esta unidad no requiere lubricaci n Puesto que el compresor no requiere ser aceitado la aplicaci n de aceite a cualquier componente podr a result
18. l draw An undersized cord will cause a drop in line voltage resulting in loss of power and overheating Make sure the extension cord is in good condition NOTE Wire size increases as gauge number decreases MINIMUM GAUGE FOR EXTENSION CORDS CORD LENGTH 25 FEET 50 FEET 100 FEET 150 FEET GAUGE 12 12 10 8 Grounding Instructions DANGER Improper grounding can result in electrical shock In the event of a short circuit grounding reduces the risk of shock by providing an escape wire for the electric current The air compressor must be grounded This compressor is for use on a nominal 120 volt circuit and is equipped with a grounding wire and appropriate grounding plug that looks like the plug illustrated The plug must be used with an outlet that has been installed and grounded in accordance with all local codes and ordinances Make sure that the compressor is connected to an outlet having the same configuration as the plug No adapter should be used with this product Inspect the plug and cord before each use Do not use compressor if there are signs of damage GROUNDED OUTLET GROUNDED OUTLET BOX GROUNDING PIN DANGER Improper installation of the grounding plug can result in electrical shock If repair or replacement of the cord or plug is required do not connect the grounding wire to either flat blade terminal The wire with the green with or without yellow stripes insulation is the grounding wire and must be
19. lanca se deja en ON cuando la corriente electrica es interrumpida entoces el compresor podria tener dificultad para arrancar 12 PROCEDIMIENTO PARA EL FUNCIONAMIENTO 1 Aseg rese de que la unidad est apagada PRECAUCION Antes de usar herramientas o accesorios neum ticos revise la capacidad de presi n m xima del fabricante Le capacidad de presi n m xima debe estar sobr e 135 PSIG 2 Una la manguera neum tica y el accesorio 3 Ponga la palanca de conectar y desconectar en posici n on y deje que la presi n del tanque aumente 4 Cuando el motor se para ha alcanzado presi n de desconexi n y la unidad est lista para usarse 5 Para apagar el compresor simplemente mueva la palanca de conectar y desconectar a la posici n off 6 Deje enfriar el compresor 7 Drene los tanques de almacenamiento ve se Tanques de Almacenamiento en la Secci n de Mantenimiento MANTENIMIENTO FILTRO DE AIRE Revise el filtro de aire antes de cada uso Limpie el filtro con agua y jab n seg n sea necessario Apriete el filtro para eliminar el exceso de humedad y deje que se seque antes de volverlo a instalar Si el filtro est obstruido o da ado reempl celo ADVERTENCIA No opere el compresor de aire sin filtro de aire PRECAUCION Nunca limpie el filtro de aire con un liquido inflamable o un disolvente Vapores explosivos podr an acumularse en los tanques de aire y causar una ex
20. mente unos 5 minutos NOTA La presi n del tanque debe estar bajo 110 PSIG para que el compresor arranque Encienda la unidad para volver a arrancar el compresor Si elcompresor no arranca revise la unidad en busca de fusibles quemados el compresor puede necesitar m s tiempo para enfriarse Si el protector de sobrecarga apaga el motor frecuentemente podri a ser que hay voltaje bajo Indicaciones comunes de un voltaje bajo son 1 El motor no llega a su capacidad y velocidad 2 Los fusibles y el cortacircuitos se activan cuando searranca el compresor 3 Las luces bajan su intensidad al arrancar el compresor permanecen amortiguadas 4 Otros aparatos operados por el motor no funcionan en forma apropiada 5 Hay demasiados aparatos operados por el motor en el mismo circuito FUNCIONAMIENTO DEL INTERRUPTOR DE PRESION El compresor es operado por medio de una palanca ON AUTO OFF localizada en un lado del interruptor de presion Gire la palanca a la posicion ON AUTO y el compresor arrancara y parara automatica mente dentro del rango de presion del interruptor El interruptor esta ajustado de fabrica para arrancar el compresor a presiones inferiores de 110 PSI y para cuando la presion alcanza 135 PSI en el tanque Para parar el compresor gire la palanca a la posicion OFF NO PARE EL COMPRESOR REMOVIENDO LA CLAVIJA DEL TOMACORRIENTE La palanca ON OFF opera una valvula la cual alivia la presion del compresor Si la pa
21. mportant safety instructions which 1 The compressor should be located in a dry clean and well ventilated area 2 Inspect hose plug and cord for signs of damage before use Do not use if a deficiency is found Contact your nearest service center for replacement parts Never operate a damaged unit 3 Do not tamper with the safety valve It has been factory set Any adjustment of this valve could cause serious injury 4 This air compressor needs no lubrication Applying oil to any part could result in polluted air delivery to the air handling equipment 5 Compressed air must never be aimed at anyone because it can cause serious injury Keep children away WEAR EYE PROTECTION 6 All air compressors generate heat even under normal operating conditions To avoid serious burns never touch the air compressor during or immediately after operation 7 When unit is not in use wrap cord securely and store in dry place Do not abuse cord or plug 8 Before servicing cleaning or removal of any part shut off power and relieve pressure from tank 9 This system produces 135 PSI To avoid rupture and injury do not operate this pump with components rated less than 135 PSI working pressure including but not limited to spray guns hose and hose connections without pressure regulator If warranty service or repair is needed contact your nearest authorized service center If one does not exist in your area contact the factory Unaut
22. n quand la puissance lectrique est interrompue le compresseur peut avoir la difficult de d marrer avec cette pression MODE D EMPLOI 1 Assurez vous que le levier marche arret se trouve sur la position position d arr t A ATTENTIONI Avant de vous servir d outils ou d accessoires a air comprim v rifiez le taux maximum de pression recommand par le fabricant Ce taux doit tre sup rieur a 135 PSIG 2 Attachez le tuyau el l accessoire 3 Mettez le levier sur la position marche et laissez la pression monter dans le r servoir 4 Quand le moteur s arr te il a atteint son niveau de pression d arr t et l appareil est pr t fonctionner REMARQUE Quand vous utilisez un accessoire ou un outil air comprim la pression dans les r servoirs d accumulation d croit Quand celle ci atteint un certain niveau minimum perte de pression le moteur red marrera aussit t automatiquement et fera monter la pression dans les r servoirs 5 Pour arr ter le compresseur mettez le levier marche arr t sur la position arr t 6 Laissez la compresseur se refroidir 7 Vindangez les r servoirs d accumulation voir r servoirs d accumulation la section entretien 19 ENTRETIEN Filtre air V rifiez le filtre air avant chaque utilisation de l appareil Nettoyez le filtre avec du savon et de l eau si n cessaire Eliminez l exc s d humidit du filtre et laissez le s cher avant de le remettre en place Si
23. naje una por cada tanque 3 Fije la perilla del regulador de modo que el man metro gt indique una presi n 0 en la m xima posici n girada a la derecha A Quite la tapa amarilla tirando de la misma B Gire a la presi n fijada hacia la derecha para aumentar C Empuje la tapa en el ajuste de traba 4 Gire la palanca on auto off encendido autom tico apagado del interruptor de presi n a la posici n OFF apagado 5 Conecte la manguera de aire a la salida del regulador 6 Enchufe el cord n de alimentaci n a una toma conectada a tierra o a un cord n de alargamiento aprobado Vea la secci n de Instrucciones de conexi n a tierra Gire la palanca on auto off encendido autom tico apagado del interruptor de presi n en la posici n ON encendido 7 7 Gire la perilla del regulador hacia la derecha para fijar la presi n requerida para su aplicaci n CABLES DE CONEXION Para evitar al motor disminuci n de tensi n y p rdida de potencia use una manguera adicional en lugar de un extension electrica Si hay necesidad de usar un extension electrica use nicamente un cable de conexi n de 3 hilos equipado con un enchufle de tierra de 3 gajos y un tomacorriente de tres ranuras que acepte el enchufe del compresor Aseg rese de que el cable de conexi n est en buen estado MEDIDAS MINIMAS PARA LOS CABLES DE CONEXION LONGITUD DEL CABLE 25 PIES SOPIE
24. nte indicado para talleres garajes y f bricas en donde el uso continuo exige gran fiabilidad EL MANTENIMIENTO GENERAL Y SERVICIO Lea y entienda la informaci n de este maual del propletario del compresor que opera Ki LE 115V 60Hz Requisitos del FUSIDIG e ec cccecnes sedan sande csk heey aici sbees inc cie 15A Regulaci n de Valvulas de Seguridad 165 PSIG 1138 KPa Desplazamiento de Aire 8 0 CFM 227 LPM Descarga de Aire e oeeooeeoe 5 5 CFM 50 PSI 156 LPM Q 345 RPa a ae 4 6 CFM 100 PSI 130 LPM 689 5 KPa Amps a Presi n de Trabajo cialis dni aa 13 A Control Autom tico Comienza 110 PSIG 758 KPa EE te iets Para 135 PSIG 931 KPa Tama o del Tanque ona 4 Gal POSO ida eat Ae E ee 71 Ibs Gable Conductor alicatado pia te i tri cate el 6 pies 1 83 M PSI Libras Por Pulgadas Cuadradas CFM Pies C bicos Por Minuto DISPOSICION DE LA UNIDAD UBICACION DEL COMPRESOR DE AIRE Haga uso del compresor de aire en un rea limpia seca y bien ventilada El filtro de aire debe mantenerse libre de obstrucciones que pudieran reducir el flujo de aire que recibe el compresor El compresor de aire debe ubicarse por lo menos a 12 de paredes y otras obstrucciones que puedan interferir con el flujo del aire 1 Desconecte el compresor de aire de la caja 2 Cierre la v lvula de dre
25. o the purchaser at the purchaser s cost If the repair work must be done at the Gardner Denver Thomas Inc factory transportation costs of the product or part to and from the factory must be paid by the purchaser The warranty shall not apply to any compressor which in Thomas judgement has been subject to misuse negligence or accident or which has been operated from an inadequate power supply All wearing and consumable parts are excluded under the terms of this warranty This warranty shall not apply to compressors that require oil for operation which have been operated with oil levels below that specified by Gardner Denver Thomas Inc THE MANUFACTURER LIMITS THE DURATION OF THE IMPLIED WARRANTY OF MERCHANTABILITY TO THE LIMITED WARRANTY PERIOD SET FORTH ABOVE AND OTHERWISE DISCLAIMS ALL IMPLIED WARRANTIES WITH RESPECT TO THE PRODUCT AND IT S PARTS INCLUDING WITHOUT LIMITATION THE IMPLIED WARRANTY OF FITNESS FOR A PARTICULAR PURPOSE Thomas total liability for any and all claims damages losses and injuries arising out of or relating to any breach of warranty shall not exceed the purchase price of the product IN NO EVENT WHETHER IN CONTRACT OR TORT OR OTHERWISE SHALL THOMAS BE LIABLE FOR LIQUIDATED INDIRECT EXEMPLARY INCIDENTAL SPECIAL OR CONSEQUENTIAL DAMAGES EXPENSES OR COSTS INCLUDING BUT NOT LIMITED TO 1 LOSS OF PROFITS BUSINESS OR GOODWILL 2 LOSS OF USE OF EQUIPMENT OR FACILITIES OR 3 LOSS RESULTING FR
26. own compressor simply move on off lever to the off position 6 Allow compressor to cool 7 Drain storage tank see Storage Tank in Maintenance Section MAINTENANCE Air Filter eS Inspect air filter before each use Clean filter with soap and water as necessary Squeeze excess moisture from filter and allow to dry before re installing If filter becomes clogged or damaged replace it WARNING Never clean air filter with a flammable liquid or solvent Explosive vapors may accumulate in the air tank and cause an explosion resulting in serious injury or death CAUTION Do not operate air compressor without air filter tank drain Storage Tank Both storage tanks should be drained after each use or after every four hours of operation to prevent condensation build up and corrosion inside the tanks To drain tank slowly and carefully open drain fitting tip unit upright and allow water to drain out Always drain tank before storing compressor DO NOT over tighten drain valve when closing The drain valve on this tank seals primarily through the o ring seal Over tightening the valve can damage the o ring and may cause premature failure To prevent damage stop closing the valve as soon as air can no longer be heard escaping from the valve or when finger tight NOTE When draining tank watch for debris rust particles If there appears to be debr
27. plosi n dando como resultado lesiones serias o muerte 13 TANQUES DE ALMACENAMIENTO Los tanques de almacenamiento deben vaciarse despu s de cada uso o despu s de cada cuatro horas de operaci n para prevenir la creaci n de condensaci n y corrosi n dentro de los tanques Para vaciar los tanques lentamente y con mucho cuidado abra los accesorios de desague incline la unidad hacia el drenaje y deje que se desague tanques desag e NOTA Cuando est drenado los tanques fjese si salen trozos de metal corrido se esto ocurre debe contactar a su distribuidor para posible reemplazo del tanque ADVERTENCIA No suelde en los tanques de aire de estos compresores Soldar en los tanques de aire de estos compresores puede da ar seriamente la fortaleza del tanque y causar una situaci n extremadamente peligrosa Una soldadura de cualquier tipo en los tanques puede ocasionar la perdida de la garantia Si algun servicio de garantia o cualquier reparo es necesario comuniquese con su distribuidor m s cercano Si este no existe comuniquese con la f brica Cualquier desmontaje desautorizado en la unidad cancelara la garantia de la f brica 14 PRECAUTIONS D EMPLOI A ATTENTION Veuillez lire attentivement ce manuel d utilisation avant de vous servir de ce compresseur d air 1 Le compresseur doit tre utilis dans un endroit sec propre et bien a r 2 Avant l emploi
28. s cubes par minute USAGE INSTALLATION Emplacement du compresseur d air Faites fonctionner le compresseur d air dans un endroit propre sec et bien aer Le filtre a air ne doit jamais tre bouch ce qui r duirait le d bit d air au compresseur Le compresseur d air doit tre plac 4m 12 pieds au moins de murs ou d autres l ments d obstruction qui pourraient interf rer avec le d bit de lair q 1 Retirez le compresseur d air du bo tier 2 Fermez le robinet de purge de chaque r servoir 3 Tournez le bouton du r gulateur compl tement vers la gauche jusqu ce que l indicateur de pression affiche 0 A Retirez le bouchon jaune B Tournez pour r gler la pression vers la droite pour l augmenter C Remettez le bouchon en place pou verrouiller le r glage 4 Basculez le levier ON AUTO OFF marche auto arr t du commutateur de pression sur a OFF ARR T E 5 Raccordez le tuyau a air a la sortie du r gulateur 6 Branchez le cordon d alimentation sur une prise mise a la terre ou une rallonge homologu e Voir le chapitre concernant les instructions de mise a la terre Basculez le levier ON AUTO OFF marche auto arr t du commutateur de pression sur ON MARCHE 7 Tournez le bouton du r gulateur de pression vers la droite pour r gler la pression requise 16 Rallonge Electrique Pour viter des chutes de voltage et des pertes de puiss
29. s del terminal El alambre con el aislamiento verde con o sin rayas amarillas es el alambre conectado a tierra Consulte con un electrista calificado si no comprende completamente las instrucciones que se dan aqui para hacer la conexi n a tierra o si no est seguro de haber hecho la conexi n a tierra en forma apropiada EXPLODED VIEW AND PARTS LIST TANK PARTS LIST 1 ann Regulator 13 638975 Safety Valve 165 PSI 1 2 lees al Stack Tank Assy 4Gal Black 1 14 633529 Pipe Plug 14 NPT__ 2 a 625106 Bot 3816 x 75 3 15 638200 corae 1 4 626832 Iw La 16 624510 Tubinginsert f1 5 626377 clip wiring 1 17 615548 untoader Tube 13 1 6 624654 Bumper 4 18 624361 Elow Poly Fio 1 7 625406 Screw 114 14 x 75 Tapping 4 19 638263 Check Vane 1 e 604220 HandGrip 20 615912 Sleeve Self Aligning 2 a leen Drain Cock 14 NPT 2 21 626750 Nut Self aligning 2 624925 Nipple apt later Exhaust Tube 602652 _ Pressure Switch 110 135 PSI 23 624714 Connector Mate 1 12 eme Pressure Gauge 114 NPT 2 10 COMPRESSOR PARTS LIST Key Part No Description Qty S 1913 Rebuild Kit 1 625198 Screw 10 24 7 8 1 603152 Start Capacitor 189 227 mfd 1 603155 Capacitor Cover Small 1 603153 Run Capacitor 45 mfd 1 Capacitor
30. witch The compressor is operated by an on auto off lever on the side of the pressure switch By turning the lever to the AUTO position the compressor will start and stop automatically within the settings of the pressure switch The pressure switch is factory adjusted to start the compressor when the tank pressure drops below 110 PSIG and to stop Lever when tank pressure reaches 135 PSIG To stop the compressor turn the lever clockwise to the OFF position DO NOT STOP THE COMPRESSOR BY REMOVING THE ELECTRICAL PLUG The on off lever operates a valve which relieves pressure from the compressor If the le ver is left on when the electric power is interrupted the compressor may have difficulty in starting under this pressure Operating Procedures 1 Make sure on off lever is in the off position f Air Regulator WARNING Before using air tools or accessories check manufacturer s maximum pressure rating Maximum pressure rating must be above 135 PSIG 2 Attach air hose and accessory to air regulator Remove orange pull plug 3 Turn on off lever to the on position and allow tank pressure to build 4 When the motor stops it has reached cutout pressure and the unit is ready for use NOTE When using an accessory or air tool pressure in the storage tank decreases When it reaches a certain low level cut in pressure the motor will automatically restart and raise the pressure in the storage tank 5 To shut d
Download Pdf Manuals
Related Search
Related Contents
EncoreAnywhere Help Guide Betriebsanleitung - SMA STRING-MONITOR SSM-U-1610 / SSM LC-46LE925E/RU Operation-Manual ES ダウンロード - 121ware.com Acer Aspire S5 USER`S MANUAL ERRATA Sanyo PLC XF10NZ Multimedia Projector Gebruiks en installatiehandleiding Dru Global 40 CF Yamaha PSR-E223 MIDI keyboard 見えるくん(No. GOD90B)取扱説明書 Copyright © All rights reserved.