Home
        C€ - Quick Cable Corporation
         Contents
1.       Si l indicateur devient jaune  le niveau d acide est bas et l accumulateur est en  phase terminale  SI L INDICATEUR EST JAUNE  IL NE FAUT PAS TENTER DE  RECHARGER OU DE V  RIFIER PAR FORT D  BIT  ll faut remplacer  l accumulateur       L accumulateur doit   tre charg      au moins 75   de sa capacit   avant d   tre v  tifi      fort    d  bit  Si l   tat de charge est moindre  les r  sutats ne seront pas pr  cis           F  On doit d  terminer l   tat de charge des accumulateurs scell  s avec un voltmetre              Voltage   tat de charge Moyenne de densit    aux bornes approximative aux cellules                            Propre    fort 12 60 100  1 255 Propre     d  bit 12 40 75  1 225 fort d  bit  Impropre au 12 20 50  1 190 Impropre au  0   fort d  bit       a en fort d  bit          11 80 0  1 120          V  RIFICATION DU VOLTAGE AUX BORNES    A  S assurer que la manette de d  bit est    son point mort  OFF     B  Brancher la pince rouge        la bome de l accumulateur        C  Brancher la pince noire        la bome de l accumulateur        D  Si la lecture est moins que 12 4 volts  l accumulateur doit   tre recharg   avant de faire la  v  rification a fort d  bit    NOTA  Sile voltage ne peut   tre r  tabli    12 4 apr  s la recharge  l    accumulateur doit     tre remplac      2    A  Si le voltage aux bomes est sup  rieur    12 6 V  il faut enlever la charge superficielle aux  plaques avant de faire la v  rification    fort d  bit  sinon la lecture de la 
2.    DHC 500A2    CE    500AMP CARBON PILE BATTERY TESTER  TEST PROCEDURES   INSTRUCTIONS       WARNING   This unit is built with a beeper which will  alarm during load test after 15 seconds  When you hear  the beep  you must read voltage quickly and then turn off  load immediately        DHC 500A2  500AMP CARBON PILE BATTERY TESTER  TEST PROCEDURES   INSTRUCTIONS    WARNING    Working in the vicinity of a lead acid battery is dangerous  Batteries generate  explosive gases during normal battery operation  It is of utmost importance that  each time before using your tester  you read these instructions very carefully   To reduce risk of battery explosion  follow these instructions and those published by  the battery manufacturer and manufacturer of any equipment you intend to use in the  vicinity of the battery  Observe cautionary markings on these items    Do not expose the tester to rain or snow    Do not operate tester with damaged cables replace them immediately    5 Do not operate tester if it has been damaged in any way  Take it to a qualified  auto technician for repair    CARBON PILE LOAD IS  ON  TO PREVENT BREAKAGE OF CARBONS  DURING SHIPMENT  BE SURE TO TURN LOAD  OFF  BEFORE  CONNECTING TESTER TO BATTERY          N    bo    D    PERSONAL SAFETY PRECAUTIONS   Someone should be within range of your voice or close enough to come to your  aid when you work near a lead acid battery   Have plenty of fresh water and soap nearby in case battery acid contacts skin   clothing or
3.  8 9 Volts  10  F    12  C  8 7 Volts   O  F     18  C  8 5 Volts                            H L accumulateur est en bon   tat si le voltage est   gal ou plus   lev   que celui indiqu   au  tableau  L   accumulateur est    remplacer si le voltage baisse plus bas que celui indiqu          Il est normal qu un v  rificateur    fort d  bit a piste de  carbone produise une grande quantit   de chaleur    l usage   Il est important d accorder assez de r  pit    l instrument  entre les v  rifications pour le laisser se refroidir et   viter de  se br  ler au contact du bo  tier        NOTA  Sur les installations    plusieurs accumulateurs  on n   en v  rifie qu   un    la fois     5  V  RIFICATION DU CIRCUIT DE CHARGE  ALTERNATEUR ET    R  GULATEUR DE VOLTAGE    A Relier l appareil comme pour la v  rification d accumulateur    B D  marrer le moteur et le laisser r  chauffer    sa temp  rature de croisi  re    C Augmenter le r  gime    1200 ou 1500 rpm  ATTENTION   I faut surveiller les pi  ces  actives du moteur  Ne pas tourner la manette de d  bit    D Noter le voltage  Si l aiguille est dans l   chelle rouge  il y a indication de probl  me dans  le circuit de charge emp  chant la pleine charge de l accumulateur  Si l aiguille est plus    lev  e que l   chelle verte  O K    il y a indication que le circuit est d  fectueux et surcharge  l accumulateur           6  VERIFICATION DU DEMARREUR  v  hicules 12 volts   Cette v  rification r  v  le toute anomalie dans le d  bit du circuit de 
4.  YELLOW   E The battery must have a minimum 75  state of charge before being load tested   If battery state of charge is below 75   load test results will NOT be accurate           F Itis highly recommended that maintenance free batteries should be tested with a  voltmeter to determine state of charge            Open Circuit Approximate Average Cell  Voltage State of Charge Specific Gravity                      OKAY to 12 60 100  4 255 OKAY to  Load Test 12 40           75         1 225 Load Test  0    DO Not 12 20 50  1 190 DO Not  Load Test 12 09 2 ee Load Test   11 80           0         1 120 s       OPEN CIRCUIT VOLTAGE TEST   A Make sure load knob is in the OFF position    B Connect tester     Red lead to Battery     terminal    C Connect tester     Black lead to Battery     terminal    D If voltmeter reading is less than 12 4 volts  battery must be charged and retested  before continuing    NOTE  If battery voltage is less than 12 4 volts after charging  replace the battery     2  REMOVING THE SURFACE CHARGE    A If your open circuit voltage reading is above 12 6 volts  remove the surface  charge before load testing  Failure to do so will result in inaccurate test readings   B Three possible ways to remove a surface charge    1 Turn headlights  high beam  on for 3 to 5 seconds    2 Disable ignition  crank starter over for 10 to 15 seconds    3 Using a variable carbon pile load tester  load battery for 10 to 15 seconds at  150 amp load  Make sure load knob is in the OFF
5.  baigner les yeux dans de l eau fra  che  courante si possible  pendant  dix minutes et rechercher un avis m  dical sans tarder    On ne doit jamais fumer ou tol  rer la pr  sence d   tincelles ou de flammes pr  s de  l accumulateur et du moteur    Il faut   viter le contact d outils m  talliques avec l accumulateur  Il pourrait en r  sulter une    tincelle  m  me un court circuit de l accumulateur  ou d autres composantes  qui pourrait  engendrer une explosion    Ne pas porter de bijoux m  talliques pendant les travaux pr  s des accumulateurs  Une  bague  un bracelet  un collier peut cr  er un court circuit d une intensit   capable de faire  fondre le m  tal et de causer de s  rieuses br  lures     IMPORTANT      POUR ASSURER UN BON FONCTIONNEMENT DE L APPAREIL  LES  M  CHOIRES DES PINCES DOIVENT BIEN MORDRE LES BORNES DE  L   ACCUMULATEUR           PREPARATION DE L   ACCUMULATEUR     1    2  3  4    Qo m gt      Il faut s assurer qu aucun gaz ne stagne dans les environs de l accumulateur  Se servir  d un carton ou autre produit non m  tallique en guise de ventilateur    Nettoyer les bomes de l accumulateur  Prot  ger les yeux des   clats corrosifs    V  rifier le bo  tier et le couvercle  En cas de fissure  ne pas employer l appareil    Ajouter de l eau distil  e aux cellules jusqu au niveau prescrit par le manufacturier  Les  gaz intemes seront ainsi   vacu  s    viter de trop emplir    N entreprendre la v  rification    fort d  bit que si la temp  rature de l accumulateur
6.  est     plus de 60  F  16  C     Si l accumulateur doit   tre enlev   du v  hicule pour faire la v  rification  s assurer que la  cosse de la mise    la terre est enlev  e en premier et que les accessoires sont  d  branch  s  afin d   viter toute   tincelle         TABLIR L   TAT DE CHARGE    Ilest essentiel d   tablir l   tat de charge avant de v  rifier l accumulateur par fort d  bit     Le p  se acide est id  al pour indiquer l   tat de chacune des cellules  Dans le cas d un       accumulateur scell    seul le voltm  tre peut indiquer l   tat de charge       Les lectures de densit   de l acide ne doivent pas varier de plus de 50 points entre    chacune des cellules  Si une lecture indique plus de 50 points de diff  rence  il faut  remplacer l accumulateur  La densit   doit   tre au moins 1 230 dans chacune des  cellules  sinon  il faut charger l accumulateur pour obtenir cette lecture   Plus  l accumulateur est    plat  plus long est le temps de recharge  Apr  s la charge  il faut    quilibrer la charge superficielle des plaques  Sila lecture minimale de 1 230 ne peut    tre obtenue  il faut remplacer l accumulateur       Certains accumulateurs scell  s et sans entretien ont un indicateur    m  me le couvercle     La couleur de l indicateur varie selon la densit   du liquide    l int  rieur    O Sila bille verte est visible  l accumulateur est    pleine charge      Si l indicateur est obscurci et que la bille verte n est plus visible  l accumulateur doit    tre recharg   
7.  eyes   Wear safety glasses and clothing protection   If battery acid contacts skin or clothing  wash immediately with soap and water  If  acid enters eye  immediately flood eye with running cold water for at least ten  minutes and get medical attention immediately   5 NEVER smoke or allow a spark or flame in vicinity of battery or engine   Be extra cautious to reduce risk of dropping a metal tool onto the battery  It  could spark or short circuit the battery or other electrical parts and could cause  an explosion   Remove personal metal items such as rings  bracelets  necklaces and watches  when working with a lead acid battery  It can produce a short circuit current  high enough to weld a ring or the like to metal causing a severe burn   IMPORTANT   BOTH JAWS OF EACH CLAMP MUST FIRMLY ENGAGE BATTERY  TERMINAL OR IT WILL NOT FUNCTION PROPERLY          N    bow    D    N          PREPARING TO TEST    1 Be sure area around battery is well ventilated while battery is being tested  Gas  can be forcefully blown away by using a piece of cardboard or other non metallic  material as a fan    2 Clean battery terminals  Be careful to keep corrosion from coming in contact with  eyes    3 Inspect the battery for cracked or broken case or cover  If so damaged  do not  use tester    4 Add distilled water in each cell until battery acid reaches level specified by the  manufacturer  This helps purge excessive gas from cells  Do not overfill    5 Make load tests only on battery above 60  F 1
8.  position before  connection is made or removed    After removing surface charge  let battery stand for 10 minutes to stabilize        3  CALCULATE THE LOAD   A Look for either the  Cold Cranking Amps  CCA rating or the  Load Test Amps   rating on the battery decal    B The load test amps rating should be on half  1 2  of the cold cranking amps rating    C Ifthe amp hour rating is provided  load test amps should be 3 times the hour rating    D If the CCA rating and amp hour rating are not available  refer to battery catalog  for recommended CCA rating             E Sometimes the rating cannot be located  in that case the engine size may be  used as a guide to determine the battery s ampere rating  However  it is  recommended to use the manufacturers recommendations  whenever they can  be located     Engine Size Cubic Inches Cu  Centimeter Battery load Amp Rating       Small 100 to 200 1600 to 2400 100 150 Amps  Medium 200 to 350 2400 to 5600 125 200 Amps  Large 350 to 500 5600 to 8000 175 300 Amps    4  LOAD TEST THE BATTERY   A The battery must have at least 75  state of charge before load testing    B The battery should not have been heavily used or tested within the last 10  minutes    C Connect Tester leads to battery     and       terminals  Read AMPS position   Make sure load knob is in the OFF position before connecting    D Apply a load to the battery equal to 1 2 of CCA rating    E       F Read voltage at the end of the 15 seconds and then turn off load   G Compare r
9. 6  C     6 If necessary to remove battery from vehicle to test  always remove earth  terminal from battery first  Make sure all accessories in the vehicle are off to  ensure you do not cause an arc     1  CALCULATE STATE OF CHARGE    A Before a battery can be load tested  you MUST determine the state of charge   B The hydrometer is a great tester to show condition of each cell  but on batteries with  non removable caps the voltmeter is your only choice to determine state of charge   C The specific gravity readings of open vent batteries should not vary more than  50 points between cells  If the variance is more than 50 points  replace the  battery  The specific gravity should be at least 1 230 in all cells  If not  charge the  battery until 1 230 is obtained  In case the battery is very low  a longer period of  time for charging may be required  After charging  remove the surface charge  from the battery  If charging the battery will not bring the charge to 1 230 then the  battery should be replaced   D Maintenance free and sealed batteries have an indicator built into the battery  cover  The color of this indicator verifies the gravity condition of the battery      Ifthe green ball is visible  the battery is charged     If the indicator is dark and the green ball is not visible  the battery is partially  discharged      If the indicator is light yellow  the battery is low on fluid and near the end of its  useful life  DO NOT ATTEMPT RECHARGING OR TESTING IF THE  INDICATOR IS
10. attery life  Perform battery load test  Proceed if battery is GOOD     ENGINE MUST BE AT NORMAL OPERATING TEMPERATURE FOR THIS TEST    A Connect negative  black  clamp to the negative  NEG  N       battery post   Connect positive  red  clamp to the positive  POP  P     battery post  Rock  clamp back and forth to ensure a good electrical connection    B Disable the ignition system so the car will not start    C Crank the engine and note the voltage reading during cranking    D A meter reading of 9 volts or less indicates excessive current draw  This may be  due to bad connections or a failing starter motor  or the battery is too small for  the vehicle s requirements           DHC S00A2    CE    V  RIFICATEUR D ACCUMLATEUR     PISTE CARBONE DE 500 A   MODE D EMPLOI   CONSEILS       ATTENTION   cet appareil est   quip   d une alarme qui se  d  clenche 15 secondes apr  s avoir commenc   le teste de  charge  Quand vous entendez cette alarme  lisez rapidement les  donn  es techniques  voltage et amp  rage  et arr  tez  imm  diatement le teste de charge en tournant le bouton sur OFF              DHC 500A2    VERIFICATEUR D   ACCUMULATEUR    PISTE DE CARBONE DE 500 A   MODE D   EMPLOI  I CONSEILS     ATTENTION     1    hw    a    Il faut consid  rer le travail pr  s des accumulateurs comme dangereux  Les  accumulateurs produisent des gaz explosifs durant leur fonctionnement  Il est de la plus  grande importance de lire le mode d emploi  chaque fois  avant de se servir de cet  apparei
11. d  marrage qui rend les  d  marrages difficiles et qui hypoth  que l accumulateur  Il faut  d abord  faire la  v  rification    grand d  bit de l accumulateur avant de proc  der    cette v  rification        LE MOTEUR DOIT   TRE    SA TEMP  RATURE DE CROISI  RE POUR ASSURER UN  R  SULTAT PR  CIS    A Brancher la pince n  gative  noire     la borne n  gative  NEG  N      Brancher la pince  positive  rouge     la bome positive  POS  P      Bien faire mordre les m  choires des  pinces sur les bomes en les remuant de gauche    droite afin d assurer un bon contact    lectrique    B D  lester l allumage pour emp  cher le moteur de fonctionner    C Faire toumer le d  marreur et noter le voltage pendant le d  marrage    D Une lecture inf  rieure    9 volts r  v  le un surcro  t d intensit   requis au circuit  qui pourrait    tre caus   par de la corrosion aux raccords ou un d  marreur mal en point ou un  accumulateur trop faible pour les besoins du v  hicule        
12. e du Pouces Centim  tres Intensit   de d  bit  moteur cubes cubes de v  rification  Petit 100    200 1600    2400 100 150 A   Moyen 200    350 2400    5600 125    200 A   Grand 350    500 5600    8000 175    300 A   4  VE 1         A L   tat de charge de l accumulateur doit   tre au moins au   de son potentiel avant de  pouvoir effectuer une v  rification    fort d  bit    B L accumulateur de doit pas avoir   t   soumis    une forte d  charge depuis au moins 10  minutes    C Brancher les pinces aux bomes     et     de l accumulateur apr  s s   tre assur   que la  manette est    son point mort  OFF     D Toumer la manette jusqu    ce que l amp  rem  tre indique l intensit   de d  bit de  v  rification    quivalant      du potentiel de d  marrage ou 3 fois le potentiel en amp  res   heure    E Maintenir ce d  bit pendant 15 secondes    F Noter le voltage obtenu apr  s cette p  riode de temps  puis rel  cher le d  bit en toumant  la manette    son point mort    G Comparer le r  sultaf aux donn  es imprim  es sur le c  t   du v  rificateur    Pass     tant  acceptable et   Fail   indiquant un accumulateur    remplacer  Le tableau ci dessous  indique le voltage minimal acceptable apr  s le fort d  bit  mais  compens   pour la  temp  rature de l accumulateur                    Temp  rature de l accumulateur Voltage minimal acceptable   70  F  21C             9 6 Volts  60  F  16  C  9 5 Volts  50  F  10  C  9 4 Volts  40  F  5C  9 3 Volts  30  F     1  C  9 1 Volts  20  F     7  C 
13. eading with PASS FAIL voltage chart on side of tester  or use chart  shown as below to compensate for battery temperature                       At Battery Temperature Of Voltage Should Not Drop Below   70  F  21         9 6 Volts  60  F  16         9 5 Volts  50  F  10  C       9 4 Volts  40  F  5C  9 3 Volts  30  F     1  C  9 1 Volts  20  F     7C  8 9 Volts  10  F     12  C  8 7 Volts   O  F     18  C  8 5 Volts                      H Battery is GOOD if voltage is at or ABOVE volt readings shown on chart  Battery  is BAD if voltage drops BELOW volt readings shown on chart        VARIABLE LOAD CARBON PILE TESTERS PRODUCE  HEAT WHEN IN USE  CARE MUST BE TAKEN TO ALLOW  SUFFICIENT TIME TO COOL DOWN BETWEEN TESTS  TO AVOID INJURY DUE TO HEAT BUILD UP        NOTE  On vehicles with multiple batteries  only one battery at a time should be tested     5  TESTING THE CHARGING SYSTEM  ALTERNATOR  amp   REGULATOR TEST     A Connect the tester the same as for battery testing    B Start the engine and allow it to reach normal operating temperature    C Run engine at 1200 to 1500RPM  CAUTION  Stay clear of moving engine parts   Do not turn on the load switch    D Read the voltmeter  A reading in the red band area indicates a problem in the  charging system that will undercharge a battery  if the meter is beyond the OK  area  the charging system is likely to overcharge the battery     6     This test identifies excessive starter current draw  which makes starting difficult  and shortens b
14. l    Pour diminuer la possibilit   d explosion d un accumulateur  on doit suivre les conseils de  ce mode d emploi  de ceux publi  s par les manufacturiers d accumulateurs ainsi que  ceux des diff  rents appareils qui peuvent   tre employ  s pr  s des accumulateurs  On  doit  aussi  observer les avis de s  curit   apparaissant sur ces composantes    Ne pas se servir du v  rificateur sous averse de pluie ou de neige    Ne pas se servir du v  rificateur si les c  bles sont endommag  s  II faut les remplacer  aussit  t    Ne pas se servir du v  rificateur s il a   t   endommag   de quelque fa  on que ce soit  II  faut le faire examiner et r  parer par un technicien automobile qualifi         LA R  CEPTION  LA PISTE DE CARBONE EST TOTALEMENT ENGAG  E POUR  LA PROT  GER DURANT LE TRANSPORT  IL FAUT S   ASSURER QUE LA  MANETTE DE D  BIT EST COMPL  TEMENT TOURN  E    SON POINT MORT   OFF  AVANT DE S   EN SERVIR     tres S  CURITAIRES PERSONNELS    a kw N    D           Lors de travaux pr  s d un accumulateur au plomb et acide  on doit s assurer qu une autre  personne est    port  e de voix ou assez pr  s pour pouvoir porter secours en cas de  besoin    On doit s assurer de la disponibilit   d eau fra  che et de savon en cas de contact  accidentel sur la peau  les v  tements ou dans les yeux    On doit porter des lunettes de s  curit   et des surv  tements protecteurs    Apr  s tout contact direct avec de l acide  il faut rincer la peau et les v  tements    l eau  savonneuse     faut
15. v  rification sera  fauss  e    B  Trois mani  res d   quilibrage sont possibles     1 Brancher les phares en mode d  passement pendant 3    5 secondes   2 D  lester l allumage et faire fonctionner le d  marreur pendant 10    15 secondes   3 Toumer la manette de fort d  bit de l appareil jusqu    une lecture de 150 A et maintenir  pendant 10    15 secondes  S assurer que la manette est au point mort avant de  brancher les pinces ou de les d  brancher    Apr  s l     quilibrage  on doit attendre une dizaine de minutes pour atteindre une   bonne stabilisation     3  CALCULER LE D  BIT    A  Trouver le potentiel de d  marrage en amp  res de l accumulateur   CCA   ou l intensit   du  d  bit de v  rification  Load Test Amp   sur l   tiquette de l   accumulateur    B  L intensit   du d  bit de v  rification est la moiti    1 2  du potentiel de d  marrage en  amp  res    C  Si seul le potentiel en amp  res heure est connu  il faut le multiplier par 3 pour obtenir  l intensit   de d  bit de v  rification    D  Si aucune donn  e n est mentionn  e sur l accumulateur  on doit se r  f  rer au catalogue  du manufacturier pour trouver le vrai potentiel de d  marrage en amp  re  CRANKING  AMPERAGE  ou le potentiel en amp  res heure           E  Dans certains cas  aucune donn  e ne peut   tre obtenue  On doit donc estimer le  potentiel de l accumulateur par la taille du moteur qui y est reli    Mais une recherche  des caract  ristiques du manufacturier est de beaucoup plus juste        Taill
    