Home
comfort form
Contents
1. Memory button memory recall button Connecting socket for mains adapter Start Stop button Battery compartment removable battery compartment cover EN 34 Air socket air connector Air hose Artery marking White marking for arm circumference Cuff Measurement arrow for arm circumference Operating the unit D 2 Control displays DE wg Li Memory location or date time SYS Systole DIA Diastole PUL 1 min Pulse calculates pulse frequency per minute Battery charge display Failure and error messages Page EN 46 Err 300 1 2 Ki ans ee 4 n d A ge gt er JEUN mme LL Wee LU m LI x a x ee LI e j A ES Deflate cuff Pulse signal display or irregular pulse waves Inflate cuff WHO classification Page EN 41 Memory identifier EN 35 D Operating the unit 3 Important instructions for use Refrain from drinking alcoholic or caffeinated beverages and smoking at least one hour before measuring Please rest at least 5 minutes before measuring Depending on the previous degree of stress exertion this can even require up to one hour Expose the upper arm the clothes must not impair the blood flow in or from the arm as this influences the blood pressure at the measurement point Body posture must be relaxed For this purpos
2. E Manufacturer Mains adapter specifications If using the optionally available mains adapter Equipment class Il double insulated Internal fuse For indoor use only role e p Internal polarity positive EN 52 General provisions ER 2 Disposal Batteries and technical appliances must not be disposed of with domestic waste but should be handed in at the appropriate collection and disposal points EN 53 DES Maintaining the unit e The unit contains sensitive parts and must be protected against strong variations in temperature air humidity dust and direct sunlight e The unit is neither impact resistant nor shock proof We recommend that you have the intactness and accuracy of the display checked after heavier falls or impacts e The unit is not waterproof e If the unit becomes dirty during use use a soft dry cloth to clean the unit Do not use benzene thinners or other strong solvents e Do not scrub or machine wash the cuff If the cuff gets dirty during use use a synthetic cleaner and softly rub the surface e Iftheunithas been opened it must be subjected to a metrological inspection conducted by an authorised organisation e Make sure that liquid cannot get into the air hose Dry thoroughly EN 54 Warranty G Warranty furnished The device has been manufactured and tested with great care However in the unlikely event of a defect being detected after delivery we provi
3. i Movement durin If necessary interrupt then inflated 9 y P measurement measurement measure again after a break of 5 minutes No display after Batteries inserted Check position of batteries unit is switched incorrectly ER Batteries flat Change batteries Battery compartment dirty Clean battery compartment Measurement Batteries flat Change batteries interrupted Measured Was the correct Repeat measurement values measurement position ensuring correct body posture extremely high maintained Do not move your arm and do or low not speak Was the necessary Repeat measurement after a rest observed prior to break of approx 3 5 mins measurement Do not move arm Do not talk EN 47 DI Technical information Technical information D The unit may only be repaired by the manufacturer or by an expressly authorised Mesaremencance adi bo sont isation nn Diastolic 40 150 mmHg Pulse 40 160 pulses min Please contact UEBE Medical GmbH Error limits Blood pressure measurement corresponds to EN Zum Ottersberg 9 1060 Part 3 Pressure measurement 3 mmHg Pulse 97877 Wertheim Germany measurement 5 Phone 49 0 9342 924040 Serial number The unit bears a serial number SN which provides clear Fax 49 0 9342 924080 ARCO SARA E mail info uebe com Internet www uebe com Power supply Battery type 4 x 1 5 V round cells alkali manganese LR 6 lithium FR 6 Durability over 80
4. Im Auslieferungszustand ist diese Funktion deaktiviert Aktivieren der Datum Uhrzeit Funktion Zum Aktivieren der Datum Uhrzeit Funktion dr cken Sie die Start Stop Taste und gleich danach w hrend die Display Komplettanzeige sichtbar ist die Speicher Taste Die Funktion kann auf die gleiche Weise jederzeit wieder deaktiviert werden Datum Uhrzeit einstellen Auf dem Display erscheint zuerst die vierstellige Jahreszahl Bild 1 Durch Dr cken der Speicher Taste stellen Sie die Jahreszahl ein Mit dem Dr cken der Start Stop Taste best tigen Sie das gew hlte Jahr und wechseln zur Einstellung des Datums Stellen Sie mit der Speicher Taste den Monat ein und be st tigen Sie diesen mit der Start Stop Taste Verfahren Sie entsprechend bei der Einstellung des Tages der Stunden und Li der Minuten Bild 2 Bild 3 Datum Uhrzeit ndern Zum ndern von Datum und Uhrzeit nehmen Sie eine Batte rie heraus und warten Sie bis das Display erloschen ist Da nach k nnen Sie Datum und Uhrzeit wieder neu einstellen Bild 2 Ausschalten der Datum Uhrzeit Funktion Zum Ausschalten der Datum Uhrzeit Funktion dr cken Sie die Start Stop Taste und gleich danach die Speicher Taste Bei aktivierter Datum Uhrzeit Funktion wird die Uhrzeit auch bei abgeschaltetem Ger t im Display angezeigt Bild 3 DE 11 7 Anlegen der Manschette e Oberarm freimachen e Schieben Sie die Manschette ber den Oberarm bis die Unterkante de
5. Respectez les instructions du mode d emploi O gt Conditions de conservation et de transport temp rature ambiante de 5 50 C en gt a 2 CH Prot gez de l humidit Humidit atmosph rique admissible jusqu 85 A 0 H D Conservez dans un endroit sec E de Fabricant Sp cification du bloc d alimentation En cas d utilisation du bloc d alimentation disponible en option Classe de protection Il double isolation Fe SEE Fusible interne O n utiliser qu en int rieur e p Polarit interne positive FR 79 fran ais A n D I n Ka IE G n ralit s Entretien de l appareil FI Si si 2 Mise rebus i 2 La s e L appareil contient des l ments sensibles et doit tre prot g contre les s Les piles et les appareils techniques ne doivent pas tre jet s variations importantes de temp rature l humidit la poussi re et une avec les ordures m nag res mais doivent tre d pos s dans des exposition solaire directe d chetteries ou des lieux de collecte sp cialement pr vus cet effet e L appareil n est pas r sistant aux chocs ni aux impacts Si l appareil a subi des chocs importants nous recommandons de faire v rifier le fonctionnement et la pr cision de l affichage e L appareil n est pas tanche l eau e Pour nettoyer l appareil sale utilisez un chiffon doux et sec N utiliser ni benzine ni solvan
6. Seitendifferenzen auszuschlie en und vergleichbare Messergebnisse zu erhalten ist es wichtig Blutdruckmessungen immer am gleichen Arm durchzuf hren Besprechen Sie mit Ihrem Arzt welche Seite er Ihnen f r Ihre Messungen empfiehlt 4 Inbetriebnahme des Ger tes Legen Sie die beigef gten Batterien in das Ger t ein Soll das Ger t mit Netzstrom betrieben werden muss der Kabelstecker des Netz teiles nicht im Lieferumfang enthalten in die Anschlussbuchse auf der rechten Seite des Ger tes eingesteckt werden Die Batterien werden automatisch abgeschaltet Bitte verwenden Sie nur das UEBE Netzteil Typ A1 Siehe Original Ersatzteile und Zubeh r Seite DE 23 5 Batterien einlegen wechseln e Batteriefach ffnen Deckel des Batteriefaches auf der Unterseite des Ger tes entfernen e Batterie einlegen Nehmen Sie die alten Batterien aus dem Ger t und legen die neuen Batterien ein Achten Sie beim Einlegen auf die richtige Polung Markierung im Batterie fach e Batteriefach schlie en Schlie en Sie das Batteriefach indem Sie den Batteriedeckel wieder in das Ger t einklipsen Sobald im Display erstmals das Symbol leere Batterie 2 erscheint k nnen Sie noch ca 30 Messungen durchf hren Bitte wechseln Sie in diesem Zeitraum die Batterien DE 10 Bedienung des Ger tes D 6 Datum Uhrzeit aktivieren und einstellen Das Ger t verf gt ber eine Datum Uhrzeit Funktion die Sie bei Bedarf zuschalten k nnen
7. als Ger t bezeichnet entschieden haben Dieses Ger t wird Patienten mit labilem Blutdruck zur h uslichen Blutdruckkontrolle und Therapieunterst tzung empfohlen visomat comfort form wendet die oszillometrische Methode zur Messung von Blut druck und Pulsrate am Oberarm an Die Manschette wird entsprechend der Abbildung auf der Manschette zuerst am Oberarm angelegt und dann mit dem Ger t verbunden Nach Dr cken der Start Stop Taste beginnt das System mit dem automatischen Druckaufbau In k rzester Zeit registriert das Ger t die kleinen Oszillationen innerhalb der Manschette die durch das Erweitern und Zusammenziehen der Arterien im Arm Herzschlag ent stehen Der automatische Druckaufbau stoppt in der Regel ca 40 mmHg ber dem systolischen Wert Fuzzy logic Danach beginnt durch Entl ften der eigentliche Messvorgang Die Amplitude jeder Druckwelle wird in Millimeter Quecksilber ge messen umgewandelt und auf dem LCD als digitaler Wert angezeigt Das Ger t bietet neben der Angaben von Systole Diastole und Puls eine Datum Uhrzeit Funktion sowie zus tzliche Anzeigen zur Feststellung unregelm iger Pulse sowie des Pulsdruckes Unregelm ige Pulse k nnen sowohl ein Hinweis auf Herz rhythmusst rungen aber auch auf Unruhen w hrend der Messung sein Der Puls druck gibt Hinweise auf die Dehnbarkeit der Blutgef e Ein Wertespeicher speichert die jeweils letzten 60 Messergebnisse zum Vergleich Diese Anleitung soll dem Be
8. is clear unobstructed Display Err 1 Measurement error Repeat measurement Measurement could not be Do not move arm carried out due to movement Do not talk of the arm or body Display Err 2 Inflation error pressure built Check sitting of air connector up too quickly or too slowly repeat measurement Fault was recognised Repeat measurement Do not move arm Do not talk Display Err Deflation rate too high or Call the Service hotline if this too low occurs repeatedly Irregular heartbeat disruptive Repeat measurement after 3 5 movements shaking minutes rest Possible factors wobbling objects breathing depending on the severity of in deeply etc the arrhythmia affecting the measurement results must be discussed with your doctor Unusual Movement or talking during Check conditions and repeat measured measurement resting time measurement Observe values not observed feet possibly instructions for use P EN 36 crossed smoking or coffee cunsumption EN 46 Technical information D Failure Possible cause Corrective action encountered Display 0 Start Stop button Switch unit off and then on 0 accidentally pressed while again with Start Stop button battery was being changed Measurement Strong pulse restlessness or If necessary interrupt was interrupted movement detected unit measurement measure again and cuff first rejects measurement after a break of 5 minutes deflated and
9. l alto Appoggiare i piedi a terra senza accavallare le gambe Durante la misurazione bisogna rimanere fermi e tranquilli Anche eventuali movimenti di disturbo sussulti la conversazione o un atto respiratorio profondo possono compromettere il risultato della misurazione Fare attenzione al segnale che indica l irregolarit delle pulsazioni ed eventualmente ripetere la misurazione in condizioni migliori Tutti gli sfigmomanometri automatici possono occasionalmente fornire risultati di misurazione inusuali se non vengono osservate le avvertenze per l uso sopra riportate Qualora non siano state osservate ripetere la misurazione dopo una breve pausa di ca 3 5 minuti per ripristinare il circolo ematico nel braccio Suggerimento rimanendo seduti lo sfigmomanometro si spegne automaticamente ca 3 minuti dopo una misurazione Consigliamo di ripetere la misurazione trascorso questo periodo La pressione arteriosa non una grandezza fissa e nei pazienti pu salire o scendere di oltre 20 mmHg in pochi minuti IT 90 Uso dell apparecchio D 4 Al fine di evitare eventuali differenze fra destra e sinistra e di garantire risultati equiparabili si consiglia di misurare la pressione arteriosa sempre sullo stesso braccio Chiedete al vostro medico quale braccio vi consiglia di utilizzare per le misurazioni Messa in funzione dell apparecchio Inserire le batterie in dotazione nell apparecchio Se si desidera utilizzare l apparecchio co
10. pour comparaison Cette notice a pour objectif d aider l utilisateur a utiliser le tensiom tre lectronique de mani re s re et efficace Cette notice a doit toujours tre conserv e avec le produit et transmise avec celui ci le cas ch ant L appareil doit tre utilis conform ment au processus d crit dans le mode d emploi et ne doit pas tre utilis d autres fins Veuillez lire attentivement le mode d emploi avant d utiliser l appareil FR 57 fran ais CA dei Un x A Consignes de s curit 1 Remarques importantes pour le patient e L appareil est con u pour une mesure non invasive de la pression art rielle systolique et diastolique et pour la determination du pouls sur les adultes c est a dire les personnes partir de 15 ans La mesure de la pression art rielle chez l enfant demande des connaissances sp cifiques Consultez votre m decin si vous souhaitez mesurer la pression art rielle d un enfant L appareil ne doit jamais tre utilis sur un nourrisson e Le brassard inclus est con u pour une circonf rence de bras de 23 43 cm Pour des circonf rences de bras de 17 25 cm un brassard plus petit est disponible accessoires page FR 77 e Les r sultats de mesure des tensiom tres automatiques peuvent tre fauss s en cas de grossesse d arythmie ou d art rioscl rose Avant l automesure de votre pression art rielle consultez votre m decin e Le brassard ne doit jamais
11. temps de repos avant la mesure Vous Voir les conseils d utilisation avez ventuellement crois les jambes page FR 63 consomm du tabac ou du caf FR 73 francais 2 dei Un de D Informations techniques Affichage des Causes possibles R solution erreurs Message 0 La touche Start Stop a t Eteindre l appareil puis remettre 0 appuy e par inadvertance en marche avec la touche Start pendant le changement des Stop piles Interrompez la mesure et r p ter apr s 5 minutes de repos Mesure L appareil constate une interrompue instabilit du pouls car brassard d gonfl vous avez boug l appareil puis regonfle interrompt la mesure et red marre Vous avez boug pendant la Interrompez la mesure et r p ter mesure apr s 5 minutes de repos Aucun affichage Les piles ne sont pas V rifiez le positionnement des n apparait positionn es correctement piles apr s la mise en cs Les piles sont dechargees Remplacez les piles Le compartiment a piles est Nettoyer le compartiment a piles encrasse Les piles sont dechargees Remplacez les piles La mesure a t elle t effectu e R p tez la mesure en veillant affich es sont tr s dans la bonne position une position correcte du bras et du hautes ou tr s corps Maintenez le bras immobile basses et ne parlez pas La mesure est interrompue Les valeurs R p tez la mesure apr s un temps de repos
12. tension diff rentielle est constante au dessus de 65 mmHg consultez votre m decin 11 Ondes pulsatoires irr guli res Si apr s une mesure le symbole sg clignote cela signifie que l appareil a enregistr des pulsations irr guli res pendant la mesure Elles peuvent traduire des troubles du rythme cardiaque ou bien vous avez boug parl ou respir profond ment Le symbole est enregistr avec la mesure laquelle il se rapporte L apparition fr quente du symbole peut tre caus e par des troubles du rythme cardiaques consultez votre m decin traitant Il faut donc v rifier les r sultats lorsque ceux ci sont accompagn s d un symbole de pouls clignotant et renouveler la mesure dans des conditions plus favorables FR 69 fran ais CA dei Un x D Utilisation de l appareil 12 Utilisation de la m moire Le tensiom tre est dot d une m moire qui enregistre automatiquement jusqu 60 r sultats de mesure ainsi que la valeur moyenne Lorsque plus de 60 mesures sont stock es en m moire la valeur la plus ancienne n 60 est supprim e pour faire place la valeur nouvelle n 1 9 mn C n al ur LI Pour rappeler des donn es stock es en m moire appuyez sur la touche Memory La valeur moyenne appara t l cran pr c d e d un A les valeurs de systole diastole et du pouls ainsi que la tension diff rentielle PP s affichent en alternance L
13. unit can be disconnected from the mains power supply at all times If the unit is not used for an extended period of time please remove the batteries Essentially all batteries can leak e The unit must only be operated with original spare parts The warranty will be invalidated if the unit is damaged by non approved accessories e Using the unit in the immediate vicinity of mobile phones microwave appliances or other devices with strong electromagnetic fields may result in impaired functioning Maintain a minimum distance of 3 m from such devices when using this unit e The display of the pulse frequency is not suitable for checking the frequency of cardiac pacemakers Cardiac pacemakers and blood pressure monitors do not influence each other regarding their mode of operation EN 32 Safety instructions A Never open or modify the unit or the cuff this is a medical device Exception replacing batteries If the unit has been opened it must be subjected to a metrological inspection by an authorised institution The cuff may be inflated on the arm only Please comply with the specified operating conditions for measurement See Technical data Page EN 47 The inflation and measuring procedure can be cancelled by pressing the Start Stop button or by removing the cuff In this case the unit stops the inflation procedure and deflates the cuff EN 33 1 Unit description D Operating the unit Display
14. 0 measurements in 2 years 3 Technical data zg Optional Stabilised type A1 mains adapter output 6 Unit type Digital automatic unit with electric pump for measuring blood pressure on upper arm Cuff Cuff type UPW for arm circumference 23 43 cm Or optionally also Dimensions Cuff type US for arm circumference 17 25 cm Weight Ambient temperature 10 to 40 C rel air humidity up to 85 not condensing air pressure 700 to 1040 hPa Dispi oi un ar meas igt Storage and transport Ambient temperature 5 to 50 C rel air humidity up pay conditions to 85 not condensing air pressure 700 to 1040 hPa Memory 60 measured values stored automatically and average value A Measurement procedure Oscillometric determination of systole diastole Protection class IP IP 20 Protected against solid foreign particles with a diameter of more than 12 5 mm no protection against Reference procedure of Auscultatory measurement water Inflating pressure Fuzzy logic controlled Classification Internal power supply by battery EN 48 EN 49 D Technical information 4 Original spare parts and accessories The following original spare parts and accessories are available from specialist dealers Cuff UPW for arm circumference 23 43 cm Part no 2403001 PZN 0044977 Cuff US for arm circumference 17 25 cm Part no 2403005 PZN 0044960 Mains adapter type A1 Part no 2401020 PZN 3558547 Subject to technical modifications
15. 080 entl ftet und wie startet neu E mail info uebe com der aufgepumpt Internet www uebe com Bewegung w hrend der Gegebenenfalls Messung abbre Messung chen nach 5 Minuten Ruhepause neu messen 3 Technische Daten Nach Einschalten Batterien falsch eingelegt Position Batterien berpr fen We erscheint keine Ger tetyp Digitales Automatikger t mit Elektropumpe zur EE Blutdruckmessung am Oberarm Batteriefach verschmutzt Batteriefach reinigen Ger tema L 140 mm x B 130 mm x H 60 mm abgebrochen Gewicht 290 g ohne Batterien Messwerte sind Wurde die richtige Mess Positi Wiederholen Sie die Messung und extrem hoch bzw on eingehalten achten Sie auf die korrekte K r Anzeige LCD Anzeige Fl ssigkristallanzeige f r Mess niedrig perhaltung Bewegen Sie den Arm werte und Kontrollanzeigen nicht und sprechen Sie nicht Speicher 60 Messwerte automatische Speicherung und Mittelwert A Wurde die n tige Ruhe vor der Wiederholen Sie die Messung nach Messung eingehalten ca 3 5 min Pause Bewegen Sie den Arm nicht Sprechen Sie nicht Messverfahren Oszillometrische Bestimmung von Systole Diastole und Puls Referenzverfahren der Auskultatorische Messung klinischen Pr fung Aufpumpdruck Fuzzy logic gesteuert DE 20 DE 21 D Technische Informationen Messbereich Systolisch 50 250 mmHg Diastolisch 40 150 mmHg Pulsmessung 40 160 Puls min Fehlergrenzen Blutdruck
16. 3 5 minuti Non muovete il braccio Non parlate IT 101 O 2 S O 2 DI Informazioni tecniche 2 Assistenza Clienti L apparecchio pu essere riparato esclusivamente dal produttore o da un centro autorizzato Rivolgersi a UEBE Medical GmbH Zum Ottersberg 9 97877 Wertheim Germania Tel 49 0 9342 924040 Fax 49 0 9342 924080 E mail info uebe com Internet www uebe com 3 Dati tecnici Modello Apparecchio digitale automatico con pompa elettrica per misurare la pressione sanguigna sulla parte superiore del braccio Dimensioni Lunghezza 140 mm x larghezza 130 mm x altezza 60 mm 290 g senza batterie Display Display a cristalli liquidi LCD per i valori misurati e le indicazioni di controllo Memoria 60 valori do memorizzazione automatica e valore medio A Metodo di misurazione Determinazione WEE di sistole diastole e polso Metodo di riferimento Misurazione auscultatoria della prova clinica Pressione di gonfiaggio Con controllo Fuzzy logic IT 102 Informazioni tecniche D Intervallo di visualizzazione 0 300 mmHg della pressione Intervallo di Pressione sistolica 50 250 mmHg misurazione Pressione diastolica 40 150 mmHg Pulsazioni 40 160 pulsazioni al minuto Limiti di errore Misurazione della pressione arteriosa conforme a EN 1060 Parte 3 Misurazione della pressione 3 mmHg Misurazione del polso 5 Numero di
17. 4960 Netzteil Type A1 Art Nr 2401020 PZN 3558547 Technische nderungen vorbehalten Hersteller UEBE Medical GmbH Zum Ottersberg 9 D 97877 Wertheim DE 23 DI Technische Informationen 5 Messtechnische Kontrolle vormals Eichung Generell wird eine messtechnische Kontrolle im Abstand von 2 Jahren empfohlen Fachliche Benutzer sind in Deutschland allerdings gem Medizinprodukte Betrei berverordnung dazu angehalten Diese kann entweder durch die UEBE Medical GmbH eine f r das Messwesen zu st ndige Beh rde oder durch autorisierte Wartungsdienste erfolgen Bitte beachten Sie dazu Ihre nationalen Vorgaben Zust ndige Beh rden oder autorisierte Wartungsdienste erhalten auf Anforderung eine Pr fanweisung zur messtechnischen Kontrolle vom Hersteller Achtung Ohne Erlaubnis des Herstellers d rfen an diesem Ger t keine Ver nde rungen z B ffnen des Ger tes ausgenommen Batterieaustausch vorgenommen werden DE 24 Allgemeine Bestimmungen EN 1 Zeichenerkl rung Dieses Produkt h lt die Richtlinie 93 42 EWG des Rates vom 5 September 2007 ber Medizinprodukte ein die am 21 M rz 2010 0123 in Kraft getreten ist und tr gt das Zeichen CE 0123 T V S D Pro duct Service GmbH Schutzgrad gegen elektrischen Schlag TYP BF Gebrauchsanleitung beachten O gt Lager und Transportbedingungen Umgebungstemperatur 5 bis 50 C cn gt Di O 85 vor Feucht
18. Gebrauchsanleitung DE 2 DE 28 Instructions for use EN 29 EN 55 Mode d emploi FR 56 FR 82 Istruzioni per l uso IT 83 IT 109 i VIS omat f A w www visomat de Besser Messen Germany Inhaltsverzeichnis EN Sicherheitshinweise 1 Wichtige Patientenhinweise 2 Wichtige technische Hinweise D Bedienung des Ger tes Ger tebeschreibung Kontrollanzeigen Wichtige Anwendungshinweise Inbetriebnahme des Ger tes Batterien einlegen wechseln Datum Uhrzeit aktivieren und einstellen Anlegen der Manschette Blutdruck messen ni O Ur W D WHO Ampelfunktion 10 Pulsdruck 11 Unregelm Bige Pulswellen 12 Verwendung des Speichers Was Sie ber Blutdruck wissen sollten 1 Der systolische und diastolische Blutdruckwert 2 Warum Sie unterschiedliche Werte messen 3 Warum regelm ig Blutdruck messen gt Technische Informationen 1 Fehler und Errormeldungen Kundendienst Technische Daten Pd Original Ersatzteile und Zubeh r 5 Messtechnische Kontrolle D Allgemeine Bestimmungen 1 Zeichenerkl rung 2 Entsorgung D Pflege des Ger tes G Garantie 7 8 9 10 10 11 12 13 14 15 15 16 18 18 18 19 20 21 23 24 25 26 ER 28 Einf hrung Vielen Dank dass Sie sich f r das Oberarmblutdruckmessger t visomat comfort form nachfolgend auch
19. I n SN al nu En appuyant de nouveau sur la touche Memory la derni re valeur mesur e n 1 s affiche Lorsque la fonction date heure est activ e les valeurs de systole diastole et de pouls s affichent en alternance avec le num ro de m moire et la date apparaissent ensuite la tension diff rentielle et l heure u LI u I al Pour faire appara tre les valeurs plus anciennes activer la touche Memory plusieurs fois Les valeurs sont affich es pendant env 30 secondes Puis l appareil s teint FR 70 Utilisation de l appareil D Pour effacer des valeurs de mesure individuelles appuyer plusieurs fois sur la touche Memory jusqu l apparition de la valeur d sir e Activer une nouvelle fois la touche Memory et maintenir jusqu ce que la valeur s efface Pour effacer la totalit des valeurs stock es appeler la valeur moyenne activer une nouvelle fois la touche Memory et maintenir appuy jusqu ce que la valeur moyenne disparaisse Il n y a aucun affichage si la m moire est vide FR 71 fran ais CA del Un de Be Ce qu il faut savoir sur la pression art rielle 1 La valeur systolique et diastolique de la pression art rielle Le coeur et la circulation sanguine ont pour r le d irriguer tous les organes et les tissus et d liminer de l organisme les produits issus du m tabolisme Le coeur se contracte et se dilate environ 60 80 fois par minute un
20. Manufacturer UEBE Medical GmbH Zum Ottersberg 9 97877 Wertheim Germany EN 50 Technical information D 5 Metrological inspection previously calibration Basically a metrological inspection is recommended at intervals of 2 years However professional users in Germany have to comply with the aforementioned according to the Regulation for Operators of Medical Devices This can be implemented either by UEBE Medical GmbH an authority responsible for metrology or authorised maintenance services For this please observe your national provisions Upon request responsible authorities or authorised maintenance services receive a Test instruction for metrological inspection from the manufacturer Important No modifications e g opening the unit except to replace the batteries may be made to this unit without the manufacturer s prior permission EN 51 IER General provisions 1 Explanation of symbols This product complies with the Council Directive 93 42 EC from 5 September 2007 regarding medical devices which became 0123 effective on 21 March 2010 and bears the mark CE 0123 T V S D Product Service GmbH Degree of protection against electric shock TYPE BF Please observe operating instructions SE Storage and transportation conditions Ambient temperature 5 to 50 C cn a O 85 Protect against moisture humidity Rel air humidity up to 85 E 0 p Keep dry
21. S pour circonference 17 25 cm Art Nr 2403005 PZN 0044960 Bloc d alimentation A1 Ref 2401020 PZN 3558547 Toutes modifications techniques r serv es Fabricant UEBE Medical GmbH Zum Ottersberg 9 97877 Wertheim Allemagne FR 77 2 dei Un de D Informations techniques 5 Contr les m trologique anciennement talonnage En r gle g n rale il est recommand d effectuer un contr le des organes de mesure tous les 2 ans En Allemagne les utilisateurs professionnels sont tenus ces contr les conform ment au d cret d exploitation des dispositifs m dicaux Les contr les peuvent tre effectu s soit directement par UEBE Medical GmbH soit par une autorit comp tente ou par un service technique agr Tenir compte de la r glementation nationale en vigueur Les autorit s comp tentes ou les services techniques agr s recevront sur demande les sp cifications pour le contr le technique Avertissement Toute modification de l appareil par exemple ouverture de l appareil except pour le remplacement des piles est interdite sans l autorisation du fabricant FR 78 G n ralit s BEN 1 Explication des symboles Ce produit satisfait la directive 93 42 CE du conseil du 5 septembre 2007 sur les dispositifs m dicaux qui prend effet le 21 0123 Mars 2010 et porte la mention CE 0123 TUV SUD Product Service GmbH Degr de protection contre les chocs lectriques TYPE BF
22. WHO wird mit den Messwerten abgespeichert und ist zusam men mit diesen wieder aus dem Speicher abrufbar DE 14 Bedienung des Ger tes D 10 Pulsdruck Der Pulsdruck nicht zu verwechseln mit dem Pulsschlag gibt Auskunft ber die Dehnbarkeit der Blutgef e Ein steifes Gef system kann sich negativ auf das Herz Kreislaufsystem auswirken Studien belegen dass das kardiovaskul re Risiko ansteigt wenn der Pulsdruckwert dauerhaft gr Ber als 65 mmHg liegt Das Herz arbeitet in zwei Phasen der Kontraktionsphase Auswurfphase Systole und der Erschlaffungsphase F llungs oder Ruhephase Diastole Der Druckunter schied zwischen Systole und Diastole wird als Pulsdruck oder Pulsamplitude be zeichnet Je h her der Pulsdruck ist desto starrer sind die Gef e hoher Pulsdruck ber 65 mmHg erh hter Pulsdruck 55 bis 65 mmHg normaler Pulsdruck unter 55 mmHg Sollte Ihr Pulsdruck dauerhaft ber 55 mmHg liegen sprechen Sie mit Ihrem Arzt 11 Unregelm ige Pulswellen Sollte nach einer Messung das Zeichen f r unregelm i ge Pulswellen blinken hat das Ger t w hrend der Messung ungleichm ige Pulse registriert Dies kann durch Herzrhythmusst rungen Bewegungsst rungen Sprechen oder auch durch Tiefenatmung ausgel st werden Das Sym bol wird mit der jeweiligen Messung abgespeichert H ufigeres Erscheinen des Symbols kann durch Herzrhythmusst rungen hervorge rufen werden und muss m
23. alla vicinanza di telefoni cordless forni a microonde o altre apparecchiature che generino forti campi elettromagnetici Durante l utilizzo tali apparecchiature vanno tenute ad una distanza di almeno 3 m e L indicazione della frequenza del polso non adatta per il controllo della frequenza di pace maker pace maker e gli sfigmomanometri non interferiscono tra di loro IT 86 Avvertenze di sicurezza A Non aprire o modificare mai l apparecchio o il bracciale questo un prodotto medicale fa eccezione la sostituzione delle batterie Se l apparecchio viene aperto occorre sottoporlo a controllo metrologico da parte di un organismo autorizzato Gonfiare il bracciale solo dopo averlo applicato sul braccio Osservare le condizioni d uso previste per la misurazione Vedere i dati tecnici a pagina IT 102 Il gonfiaggio e la misurazione possono essere interrotti premendo il tasto Start Stop oppure rimuovendo il bracciale L apparecchio interrompe cos il gonfiaggio e sgonfia il bracciale IT 87 O D 2 x Bracciale D Uso dell apparecchio 1 Descrizione dell apparecchio Display Pulsante Memory richiamo della memoria Attacco alimentatore Pulsante Start Stop avvio stop Vano portabatterie sportello del vano batterie rimovibile IT 88 QO Presa per l aria connettore dell aria Tubo flessibile dell aria Marcatura per l arteria Marcatura bianca per la
24. anschette abgebrochen werden Das Ger t beendet dann das Aufpumpen und entl ftet die Manschette DE 6 Bedienung des Ger tes D 1 Ger tebeschreibung Manschette Displayanzeige Speicher Memory Taste Speicher Abruf Taste Anschlussbuchse f r Netzteil E Start Stop Taste Batteriefach Batteriefachdeckel abnehmbar Luftbuchse Luftstecker Luftschlauch Arterienmarkierung Wei e Markierung f r Armumfang Manschette Messpfeil f r den Armumfang DE 7 2 Kontrollanzeigen _ 0 E ans WR LI dee Speicherplatz oder Datum Uhrzeit SYS Systole DIA Diastole PUL 1 min Puls errechnete Pulsfrequenz pro Minute Batteriekontrollanzeige Fehler und Errormeldungen Seite DE 19 Err 300 1 2 DE 8 e Dal BR LI ege KH D Bedienung des Ger tes KI LI fu KI LI KI al a OO q GIL em un LO LU LC LU Manschette wird entl ftet Pulssignalanzeige bzw unregelma Bige Pulswellen Ger t pumpt WHO Einstufung Seite DE 14 Speicherkennung Bedienung des Ger tes D 3 Wichtige Anwendungshinweise Alkohol Nikotin oder Koffeingenuss mindestens eine Stunde vor dem Messen einstellen Vor der Messung mindestens 5 Minuten Ruhepause Je nach Schwere der vo rangegangenen Anstrengung kann dies sogar bis zu einer Stunde erfordern Oberarm fre
25. as d utilisation avec un bloc d alimentation utilisez uniquement le bloc d alimentation certifi de type A1 sp cialement destin aux appareils m dicaux Lorsque vous utilisez l appareil avec l adaptateur secteur assurez vous que l appareil peut tre d connect tout moment de la prise secteur Si vous pr voyez de ne pas utiliser l appareil pendant une longue p riode sortez les piles pour viter l oxydation En principe toutes les piles s oxydent L appareil doit tre utilis uniquement avec des pi ces de rechange authentiques Les dommages caus s par l utilisation de pi ces de fabricants tiers ne sont pas couverts par la garantie L utilisation de l appareil proximit de t l phones portables ou d appareils microondes ou autres dispositifs pr sentant de forts champs magn tiques peut provoquer des erreurs de fonctionnement Respecter une distance minimum de 3 m par rapport ces appareils L affichage de la fr quence du pouls ne convient pas au contr le de la fr quence des stimulateurs cardiaques Les stimulateurs cardiaques et les tensiom tres n ont aucune influence l un sur l autre FR 59 fran ais A Consignes de securite Utilisation de l appareil D 1 Description de l appareil A u 5 5 e N ouvrez jamais et ne modifiez jamais l appareil ou le brassard Il s agit d un appareil m dical sauf pour le remplacement des piles Au cas o l appareil aurait t ouvert
26. auf die Start Stop Taste ein schalten Folgendes Display wird sichtbar e Nachdem das Ger t seinen Abgleich gegen den Um gebungsluftdruck vorgenommen hat beginnt der auto matisch gesteuerte Aufpumpvorgang e Die Manschette wird auf den notwendigen Druck auf gepumpt Ein A blinkt in der Anzeige e Danach beginnt durch Entl ften der eigentliche Mess vorgang Das Symbol in der Anzeige blinkt zus tz lich ert nt ein Piepton f r die Pulsfrequenz e Das Ende der Messung wird durch einen langen Piep ton signalisiert die Manschette wird automatisch ent l ftet DE 13 Bedienung des Ger tes e Die ermittelten Werte von Systole Diastole und Puls sowie der Pulsdruck PP Puls Pressure wer den abwechselnd im Display angezeigt e Nach ca 3 Minuten schaltet sich das Ger t auto matisch aus 9 WHO Ampelfunktion Das Ger t stuft die gemessenen Blutdruckwerte nach den Richtlinien der Weltge sundheitsorganisation WHO ein Anhand der Farbfelder neben dem Display k n nen Sie die Einstufung bei jeder Messung ablesen Unterer Punkt gr n bedeutet Normalwert Mittlerer Punkt gelb bedeutet Grenzwert Oberer Punkt rot bedeutet Hochdruck WHO 2003 Systolischer Druck Diastolischer Druck E gen gt Oberer Wert Unterer Wert wenn bereits mmHg mmHg einer der Werte erh ht ist Millimeter E 120 bis 139 80 bis 89 Hydrargyrum Quecksilber Die Einstufung nach
27. cio o del corpo ha causato il pompaggio massimo del bracciale In alternativa il tubo potrebbe essere piegato o la presa per l aria ostruita Errore di misurazione Non possibile eseguire la misurazione a causa del movimento del braccio o del corpo Errore di pompaggio la pressione viene generata troppo in fretta o troppo lentamente stata individuata un anomalia La percentuale di sgonfiaggio permeabilit troppo alta bassa Disturbi del ritmo cardiaco disturbi dovuti a movimento tremore oscillazioni intenzionali respiri profondi ecc Il paziente si mosso o ha parlato durante la misurazione non ha rispettato il periodo di riposo ha tenuto i piedi incrociati ha fumato o bevuto caff D Informazioni tecniche 1 Messaggi d errore Errore Possibile causa Rimedio indicato Ripetete la misurazione Non muovete il braccio Non parlate Verificate che l aria riesca a passare liberamente attraverso il tubo e il connettore dell aria Ripetete la misurazione Non muovete il braccio Non parlate Controllate la posizione del connettore dell aria ripetete la misurazione Ripetete la misurazione Non muovete il braccio Non parlate Se l errore si ripete pi volte telefonare al servizio assistenza clienti Ripetete la misurazione dopo 3 5 minuti di riposo Gli eventuali influssi a seconda della gravit delle aritmie sui risultati della misurazione devono esse
28. circonferenza del braccio Bracciale Indicatore di misurazione per la circonferenza del braccio Uso dell apparecchio D 2 Indicatori di controllo Memoria o data ora SYS pressione sistolica DIA pressione diastolica PUL 1 min polso calcola le pulsazioni al minuto Indicazione di controllo batterie Messaggi d errore pagina IT 100 Err 300 1 2 bracciale si sta sgonfiando Indicatore del segnale del polso o pulsazioni irregolari L apparecchio sta pompando Classificazione OMS pagina IT 95 Memoria IT 89 O I O 2 D Uso dell apparecchio 3 Avvertenze importanti per l uso Astenersi dal consumo di alcolici nicotina o caffeina per almeno un ora prima della misurazione Prima di misurare la pressione restare a riposo per almeno 5 minuti A seconda dell intensit dello sforzo fisico precedente pu essere necessaria una pausa di riposo anche di un ora Liberare la parte superiore del braccio il flusso ematico da e verso il braccio non deve mai essere ostacolato dall abbigliamento in quanto questo compromette la pressione arteriosa sul punto di misurazione Assumere una posizione rilassata A questo scopo appoggiarsi totalmente a un tavolo non un tavolino basso da salotto Appoggiare la schiena allo schienale della sedia Appoggiare sul tavolo tutto l avambraccio tenendo il palmo della mano rivolto verso
29. couvercle dans l appareil D s que le symbole 4 appara t sur l cran env 30 mesures sont encore possibles Changer les piles pendant cette p riode FR 64 Utilisation de l appareil D 6 Activer et param trer la date et l heure L appareil dispose d une fonction date heure qui peut tre activ e si n cessaire Cette fonction est d sactiv e la livraison Activer la fonction date heure Pour activer la fonction date heure appuyez sur la touche Start Stop juste apr s pendant que toutes les fonctions s affichent sur l cran appuyez sur la touche Memory Proc dez de la m me mani re pour d sactiver la fonction Param trage date heure L cran affiche d abord des quatre chiffres de l ann e fig 1 Param trer l ann e en appuyant sur la touche Memory Valider l ann e en appuyant sur la touche Start Stop et passer au param trage de la date Appuyez sur la touche Memory pour s lectionner le mois et valider avec la touche Start Stop Proc dez de la m me mani re pour param trer le jour l heure et les minutes fig 2 fig 3 17 Modifier la date l heure Pour modifier la fonction date heure sortez une pile et attendez que l cran s eteigne Maintenant r activez la fonction date heure et reprogrammez les valeurs fig 2 Eteindre la fonction date heure Pour teindre la fonction date heure appuyez sur la touche Start Stop et sur la touche Memory imm diatement apr s Lorsque la fonct
30. de 3 5 minutes Ne bougez pas Ne parlez pas Avez vous respect un temps de repos avant de proc der la mesure FR 74 Informations techniques D 2 Service Apr s vente La r paration de l appareil doit uniquement tre effectu e par le fabricant ou par un service technique agr Veuillez vous adresser UEBE Medical GmbH Zum Ottersberg 9 97877 Wertheim Allemagne N t l 49 0 9342 924040 N Fax 49 0 9342 924080 E mail info uebe com Site Internet www uebe com 3 Caract ristiques techniques Appareil num rique automatique avec pompe lectrique pour mesurer la pression art rielle au bras Dimensions de l appareil L 140 mm x B 130 mm x H 60 mm Affichage Affichage num rique LCD des valeurs et des symboles de contr le cristaux liquides Type d appareil 60 valeurs stockage automatique et valeur moyenne A M moire M thode oscillom trique de la systole la diastole et du pouls M thode de r f rence Mesure auscultatoire clinique Pression de gonflage Fonctionnement par logique floue FR 75 M thode de mesure fran ais 2 dei Un de D Informations techniques Plage de mesure Systolique 50 250 mmHg Diastolique 40 150 mmHg Pouls 40 160 Pulsations min Pr cision Mesure de la tension correspond la norme EN 1060 Partie 3 Mesure de la pression 3 mmHg Mesure du pouls 5 Num ro de s rie Sur l appa
31. de warranty in accordance with the following terms and conditions 1 During the warranty period of 3 years from the date of purchase we reserve the right either to repair any such defect at our expense or to supply a perfect replacement unit The cost of returning the unit to our factory shall be borne by the sender UEBE shall refuse to accept return deliveries that have not been paid for by the sender 2 Excluded from the warranty are parts subject to normal wear and tear as well as damage caused by non compliance with the instructions for use improper handling e g unsuitable power sources breakages leaking batteries and or disassembly of the unit by the purchaser Furthermore no claims for damages against us are substantiated by the warranty 3 Warranty claims can only be advanced in the warranty period and by presenting proof of purchase In the event of a warranty claim the unit must be sent to the following address together with the proof of purchase and a description of the complaint UEBE Medical GmbH Service Center Zum Ottersberg 9 97877 Wertheim Germany The cost of returning the unit to our factory shall be borne by the sender UEBE shall refuse to accept return deliveries that have not been paid for by the sender 4 Inthe case of defectiveness of the goods the contractual rights of the purchaser to claim against the seller in accordance with 437 German Civil Code are not limited by the warranty Please note I
32. ded to help the user to use the digital blood pressure monitor safely and efficiently and must be kept with the product and forwarded if applicable The unit must be used in accordance with the procedures contained in these instructions and must not be used for other purposes Please read these instructions carefully before using the unit EN 30 Safety instructions A 1 Important patient instructions e The unit is designed for non invasive measurement of the systolic and diastolic blood pressure on the upper arm as well as measurement of the pulse rate of adults i e 15 years of age and older Blood pressure measurements on children require specialist knowledge Please consult your doctor if you wish to measure the blood pressure of a child Do not under any circumstances use the unit on a baby infant e The standard cuff supplied is designed for an upper arm circumference of 23 43 cm A smaller cuff accessory Page EN 50 is optionally available for arm circumferences of 17 25 cm e The measurement results of automatically measuring blood pressure monitors may be falsified by pregnancy irregular heartbeats or arteriosclerosis Measure your own blood pressure in cooperation with your doctor e Do not under any circumstances place the cuff on or over any critical point e g wound aneurysm etc Risk of injuries The supply via an intravascular access infusion could possibly be interrupted e Make sure the air hose is not ki
33. delines of the World Health Organisation WHO You can use the coloured fields to read the categorisation of each reading e The cuff is inflated to the required pressure A AT flashes in the display Lower dot Green signifies normal value Middle dot Yellow signifies borderline value Upper dot Red signifies high pressure e Then the actual measurement process starts while the cuff is being deflated The symbol flashes in the display and a beep sounds to denote the pulse frequency WHO 2003 Systolic pressure Diastolic pressure It is sufficient Upper value Lower value for one of the mmHg mmHg values to be raised millimetres of ren below 120 below 80 The categorisation according to WHO is stored with the readings and can be called up again together with the readings from the memory EN 40 EN 41 e Along beep denotes the end of measurement The cuff is automatically deflated D Operating the unit 10 Pulse pressure The pulse pressure not to be confused with the pulse beat provides an indication of the stretchability of the blood vessels A hard system of vessels can have a negative effect on the cardiovascular system Studies show that the cardiovascular risk increases if the pulse pressure value is consistently greater than 65 mmHg The heart works in two phases the contraction phase systole and the relaxation phase diastole The pressure difference between sys
34. ds you take your measurements on Initial operation of the unit Insert the supplied batteries into the unit If the unit is to be operated from the mains power supply the cable plug of the mains adapter not included in the scope of delivery must be inserted into the connection socket on the right side of the unit The batteries are switched off automatically Please use only the UEBE type A1 mains adapter See original spare parts and accessories Page EN 50 Inserting replacing batteries Opening the battery compartment Remove the cover of the battery compartment on the underside of the unit Inserting batteries Remove the old batteries from the unit and insert the new ones Please observe proper polarity marking in battery compartment Closing the battery compartment Close the battery compartment by clipping the battery cover back into the unit When the display shows the Flat battery 2 symbol for the first time the unit will still have enough charge for about 30 measurements Please change the batteries during this period EN 37 D Operating the unit 6 Activating and setting the date time The unit has a date time function which you can activate where necessary This function is deactivated when the unit is delivered Activating the date time function To activate the date time function press the Start Stop button and then immediately while the full display is visible the Memory button This
35. e sit at a table if possible the height of a dining table not a coffee table Rest your back against the backrest of the chair Rest your forearm completely flat with the palm of your hand facing upwards Place your feet on the floor and do not cross your legs t is absolutely essential to sit still and remain quiet Irregular movements vibrations shaking talking and breathing heavily will affect and may even falsify the measurement Look out for irregular pulse signals in the display if necessary repeat the measurement under more favourable conditions Unusual measurement results are possible with all automatically measuring blood pressure measurement systems from time to time Check yourself did you comply with the instructions for use above If necessary repeat the measurement after allowing the blood circulation in the arm to recuperate briefly rest for about 3 5 minutes for this purpose Tip Remain seated your monitor will switch off automatically about 3 minutes after a measurement Afterwards we recommend that you repeat the measurement Blood pressure is not a fixed value It may fluctuate upwards or downwards by more than 20 mmHg on patients within a few minutes EN 36 Operating the unit D 4 In order to rule out differences between left and right and to obtain comparable measurement results it is important always to take blood pressure measurements on the same arm Ask your doctor which arm he she recommen
36. e data ora attivata vengono visualizzati alternativamente sistole diastole e polso con i rispettivi numero progressivo e data e quindi la pressione del polso PP con la rispettiva ora a a LL LC JUN ee LI Es L Per richiamare gli altri valori misurati premere ripetutamente il tasto Memory dati memorizzati restano visibili sul display per circa 30 CH secondi Successivamente l apparecchio si spegne zu add WT IT 97 O D O 2 D Uso dell apparecchio Per cancellare singoli valori richiamare il valore desiderato premendo ripetutamente il tasto Memory Quindi premere nuovamente il tasto Memory e tenerlo premuto fino a quando il valore scompare Per cancellare tutta la memoria richiamare il valore medio premere nuovamente il tasto Memory e tenerlo premuto fin quando il valore medio scompare Se non memorizzato alcun valore non viene visualizzato nulla IT 98 Cosa necessario sapere sulla pressione arteriosa Re 1 Valori della pressione arteriosa sistolica e diastolica La circolazione del sangue ha l importante funzione di apportare sangue a sufficienza a tutti gli organi e tessuti dell organismo e di rimuovere i prodotti del metabolismo A questo scopo il cuore si contrae e si dilata a un ritmo regolare ca 60 80 volte al minuto La pressione del sangue in circolo che si genera sulle pareti arteriose durante la contrazion
37. e del cuore si chiama sistole La pressione nella fase di rilasciamento successiva quando il cuore si riempie di nuovo di sangue si chiama diastole Durante la misurazione quotidiana della pressione si rilevano entrambi questi valori 2 Perch diversi valori di misurazione La nostra pressione arteriosa reagisce a influssi esterni e interni come un sensibile strumento di misura Anche le minime variazioni possono influire sulla pressione Questo fa chiaramente capire che spesso i valori misurati dal medico o in farmacia sono pi elevati di quelli che si ottengono a casa nell ambiente familiare Tuttavia anche i cambiamenti atmosferici e climatici e le sollecitazioni fisiche e mentali possono influire sulla pressione 3 Perch misurare regolarmente la pressione arteriosa Anche il momento della giornata influisce sul valore della pressione arteriosa Durante il giorno i valori sono generalmente pi elevati di quelli che si misurano di notte nelle fasi di riposo Misurazioni uniche e irregolari dicono pertanto poco della pressione arteriosa effettiva possibile effettuare una valutazione affidabile solo eseguendo regolarmente singole misurazioni Parlate dei valori di misurazione con il vostro medico IT 99 O D O 2 Visualizzazione Err 300 Visualizzazione Err 1 Visualizzazione Err 2 Visualizzazione Err 3 Valori anomali IT 100 Sovrapressione del bracciale Un movimento del brac
38. e pulse pressure PP are shown alternately in the display m i fe i u 11 When the Memory button is pressed again the value measured last No 1 appears When the date time function is activated systole diastole and pulse are displayed alternately with memory number and date followed by the pulse pressure PP and the time IL Ja LEUR m an R i 4 Si e Press the Memory button repeatedly to call up further measured values The stored data remain visible in the display for around 30 WE seconds The unit then switches itself off i a at w 77 d EN 43 D Operating the unit To delete individual measured values press the Memory button repeatedly to call up the desired measured value Press the Memory button again and hold it until the value first flashes and then disappears To delete the entire memory call up the average value press the Memory button again and hold down until the average value has disappeared If no value is stored there is no display EN 44 What you should know about blood pressure Re 1 Systolic and diastolic blood pressure values The cardiovascular system has the important function of supplying all organs and tissues in the body with sufficient amounts of blood and of transporting metabolites For this the heart contracts and expands at a regular rate of about 60 to 80 times per minute The pressure of the flowing blood
39. en rufen Sie mit der Speicher Taste durch mehr maliges Dr cken den gew nschten Messwert auf Dr cken Sie die Speicher Taste erneut und halten Sie sie gedr ckt bis die Anzeige zuerst blinkt und danach kom plett erlischt Um den gesamten Speicher zu l schen rufen Sie die jeweilige Durchschnittswertan zeige A auf dr cken Sie die Speicher Taste erneut und halten Sie sie gedr ckt bis der Mittelwert zuerst blinkt und danach komplett erlischt Wenn kein Wert gespeichert ist gibt es keine Anzeige DE 17 ia Was Sie uber Blutdruck wissen sollten 1 Der systolische und diastolische Blutdruckwert Herz und Blutkreislauf haben die wichtige Aufgabe alle Organe und Gewebe des K r pers ausreichend mit Blut zu versorgen und Stoffwechselprodukte abzutransportieren Das Herz zieht sich dazu in regelm igem Rhythmus etwa 60 80 mal pro Minute zu sammen und dehnt sich wieder aus Der Druck des str menden Blutes der beim Zusam menziehen Kontraktion des Herzens auf die Arterienw nde entsteht wird als Systole bezeichnet Der Druck in der darauf folgenden Erschlaffungsphase wenn sich das Herz wieder mit Blut f llt wird als Diastole bezeichnet Bei Ihrer t glichen Messung ermitteln Sie beide Werte 2 Warum Sie unterschiedliche Werte messen Unser Blutdruck reagiert wie ein empfindliches Messinstrument auf u ere und innere Einfl sse Schon geringf gige nderungen k nnen auf ihn einwirken Das macht verst ndlich da
40. ern Sie sich dass keine Fl ssigkeit in den Luftschlauch gelangt Gr ndlich trocknen lassen DE 26 DE 27 G Garantie Garantieleistungen Das Gerat wurde mit aller Sorgfalt hergestellt und gepruft Fur den Fall dass es trotzdem bei Auslieferung Mangel aufweisen sollte geben wir eine Garantie zu den nachfolgenden Konditionen 1 W hrend der Garantiezeit von 3 Jahren ab Kaufdatum beheben wir solche M ngel nach unserer Wahl und auf unsere Kosten in unserem Werk durch Reparatur oder Ersatzlieferung eines mangelfreien Ger tes Die Kosten der R cksendung des Ger tes in unser Werk tr gt der Einsender Unfrei zur ck ge sendete Reklamationen werden von UEBE nicht angenommen 2 Nicht unter die Garantie fallen die normale Abnutzung von Verschlei teilen oder Sch den die durch Nichtbeachtung der Gebrauchsanleitung unsachgem e Handhabung z B ungeeignete Stromquellen Bruch ausgelaufene Batterien und oder Demontage des Ger tes durch den K ufer entstehen Ferner werden durch die Garantie keine Schadenersatzanspr che gegen uns begr ndet 3 Garantieanspr che k nnen nur in der Garantiezeit und durch Vorlage des Kauf beleges geltend gemacht werden Im Garantiefall ist das Ger t zusammen mit dem Kaufbeleg und Beschreibung der Reklamation zu senden an UEBE Medical GmbH Service Center Zum Ottersberg 9 97877 Wertheim Deutschland Die Kosten der R cksendung des Ger tes in unser Werk tr gt der Einsender Un frei zu
41. est conseill aux patients souffrant de pression art rielle instable d sireux d autocontr ler leur tension domicile et sert de soutien th rapeutique Le visomat comfort form utilise la m thode oscillom trique pour mesurer la tension et le pouls au bras Conform ment l illustration sur le brassard placer d abord le brassard autour du bras avant de le raccorder l appareil Appuyer ensuite sur la touche Start Stop et le syst me d marre automatiquement la compression Tr s rapidement l appareil enregistre les petites oscillations dans le brassard qui proviennent de la dilatation et de la r traction des art res dans le bras battement cardiaque La compression automatique cesse env 40 mmHg au dessus de la valeur de systole logique floue puis le brassard se d gonfle et la mesure commence L amplitude de chaque oscillation est mesur e en millim tre de mercure puis convertie et affich e sous forme de valeur num rique sur l cran LCD En plus de la mesure de la pression systolique diastolique et du pouls l appareil indique la date et l heure et les valeurs de pouls irr guli res ainsi que la pression diff rentielle Les pulsations irr guli res peuvent r v ler des perturbations du rythme cardiaque mais peuvent aussi signifier que vous avez boug pendant la mesure La pression diff rentielle renseigne sur les propri t s visco lastiques des art res Une m moire sauvegarde les 60 derniers r sultats de mesure
42. ettuare mai la misurazione sul lato del corpo in cui stata eseguita una mastectomia con asportazione dei linfonodi ascellari IT 85 O D O 2 A Avvertenze di sicurezza e L automisurazione non una terapia Non modificare in alcun caso il dosaggio dei farmaci prescritto dal medico e Prima di eseguire le automisurazioni leggere il capitolo Avvertenze importanti per l uso a pagina IT 90 2 Avvertenze tecniche importanti e Perla misurazione ottimale della pressione arteriosa necessaria una buona alimentazione elettrica costante Utilizzare esclusivamente batterie alcaline di lunga durata LR6 Sostituire sempre tutte le batterie contemporaneamente Sono necessarie 4 batterie da 1 5 Volt Le batterie ricaricabili hanno solo 1 2 Volt di tensione e non sono quindi adatte In caso di uso con alimentatore utilizzare solo l alimentatore specifico per prodotti medicali modello A1 Quando utilizzate l apparecchio con l alimentatore assicuratevi che l apparecchio possa essere staccato in qualsiasi momento dalla rete elettrica Se l apparecchio non viene utilizzato per un periodo prolungato togliere le batterie In linea di principio qualsiasi batteria pu scaricarsi e L apparecchio deve essere utilizzato solo con ricambi originali La garanzia decade in caso di danni dovuti all uso di accessori di terzi e funzionamento dell apparecchio pu essere compromesso d
43. fiable il est donc essentiel de proc der des mesures r guli res Parlez de vos r sultats votre m decin FR 72 Informations techniques Message d erreur Affichage Cause possible R solution des erreurs Message Brassard surgonfl Vous avez boug R p tez la mesure Err 300 et le brassard s est gonfl au maximum Ne bougez pas Ne parlez pas Eventuellement le tuyau est pli ou la V rifiez le tuyau et la fiche fiche d air est bouch e Message Erreur de mesure Vous avez boug Err 1 et l appareil n a pas pu effectuer la mesure R p tez la mesure Ne bougez pas Ne parlez pas Message Erreur de gonflage La pression Err 2 augmente trop vite ou trop lentement V rifier que le tuyau est bien enfich dans l appareil r p tez la mesure Constatation d erreur R p tez la mesure Ne bougez pas Ne parlez pas Message Taux de d gonflage trop haut ou Appelez le service en cas de Err 3 trop bas r p tition de l erreur Troubles du rythme cardiaque troubles R p tez la mesure apr s un dus un mouvement tremblements repos de 3 5 minutes Parlez oscillations intentionnelles respiration votre m decin des influences profonde etc ventuelles selon le degr d arythmie sur les r sultats de mesure Valeurs Vous avez parl ou boug pendant la V rifiez les conditions de la inhabituelles mesure Vous n avez pas respect un mesure et renouvelez la mesure
44. function can be deactivated again at any time in the same way Setting the date time The four digit number representing the year appears in the display first Fig 1 Press the Memory button to set the year Press the Start Stop button to confirm the selected year and proceed to setting the date Set the month with the Memory button and confirm this with the Start Stop button Set the day hours and minutes in the same way Fig 2 Fig 3 Li Changing the date time To change the date time function take out a battery and wait until the display goes blank Now you can reactivate the date time function and reset the date and time again Deactivating the date time function Fig 2 To deactivate the date time function press the Start Stop button and then immediately the Memory button When the date time function is activated the time is also shown in the display when the unit is switched off Fig 3 EN 38 Operating the unit D 7 Attaching the cuff Expose the upper arm Push the cuff onto the upper arm until the lower edge of the cuff is 2 3 cm above the crook of the HP arm Fig 1 Fig 2 When using the unit on the left arm the air hose runs to the unit through the middle of the crook of the arm so that the 4 cm long artery marking is automatically located centrally above the pulse position Fig 3 When using the unit on the right arm the cuff must be rotated to the left until the artery marking
45. gia il simbolo e del battito irregolare significa che l apparecchio ha registrato un polso irregolare durante la misurazione Questa irregolarit pu essere dovuta a disturbi del ritmo cardiaco oppure al fatto che il paziente si mosso ha parlato o ha respirato profondamente durante la misurazione Il simbolo viene memorizzato con la relativa misurazione La visualizzazione frequente del simbolo pu essere dovuta a disturbi del ritmo cardiaco e deve essere comunicata al proprio medico curante Per questo i risultati della misurazione accompagnati dal simbolo lampeggiante del battito devono essere considerati con occhio critico e ripetuti in condizioni pi favorevoli IT 96 Uso dell apparecchio D 12 Uso della memoria risultati delle misurazioni vengono archiviati automaticamente nella memoria La memoria pu contenere fino a 60 risultati oltre al valore medio Quando sono state memorizzate pi di 60 misurazioni il valore pi vecchio n 60 viene cancellato per registrare il valore pi recente n 1 9 on G LI m Li een Per richiamare i dati premere il tasto Memory Il valore medio dei risultati memorizzati indicato con una A i valori sistole diastole e polso nonch la pressione del polso PP vengono visualizzati alternativamente sul display e em i fe i u 11 Premendo di nuovo il tasto Memory compaiono gli ultimi valori misurati n 1 Con la funzion
46. i machen auf keinen Fall darf die Kleidung den Blutfluss in oder aus dem Arm behindern da dies den Blutdruck an der Messstelle beeintr chtigt Die K rperhaltung muss entspannt sein Setzen Sie sich dazu ganz an den Tisch m glichste H he eines Esstisches kein Couchtisch heran Lehnen Sie Ihren R cken an der Stuhllehne an Legen Sie Ihren kompletten Unterarm auf Handinnenfl che weist nach oben F e auf den Boden aufstellen Beine nicht berkreuzen Ruhe w hrend der Messung ist ein absolutes Muss St rbewegungen Ersch t terungen Sprechen und starke Atmung beeintr chtigen das Messergebnis und k nnen es verf lschen Achten Sie auf die Anzeige f r unregelm ige Pulssig nale gegebenenfalls Messung unter besseren Bedingungen wiederholen Un bliche Messergebnisse sind gelegentlich mit allen automatisch messenden Blutdruckmesssystemen m glich berpr fen Sie sich selbst Haben Sie die oben erw hnten Anwendungshinweise eingehalten Wiederholen Sie gegebe nenfalls die Messung nach einer kurzen Erholung des Blutkreislaufs im Arm ruhen Sie dazu ca 3 5 Minuten Tipp Bleiben Sie sitzen Ihr Messger t schaltet sich ca 3 Minuten nach einer Messung selbst ndig ab Danach empfehlen wir die Wiederholungsmessung Blutdruck ist keine feste Gr e Dieser kann sich bei Patienten innerhalb weni ger Minuten um mehr als 20 mmHg nach oben oder unten ver ndern DE 9 D Bedienung des Ger tes e Um
47. iederholen Wiederholen Sie die Messung Bewegen Sie den Arm nicht Sprechen Sie nicht Anzeige Ablassrate zu hoch oder zu niedrig Bei mehrmaligem Auftreten Err 3 Service Telefon anrufen Herzrhythmusst rungen Bewe Messung nach 3 5 Minuten Ruhe gungsst rungen Zittern Wackeln wiederholen Eventuelle Einfl sse Artefakte Tiefenatmung etc je nach Schwere der Arrhythmien auf die Messergebnisse m ssen mit dem Arzt besprochen werden St rung wurde erkannt Bewegen bzw Sprechen w hrend Bedingungen pr fen und Messung w hnliche der Messung Ruhezeit nicht wiederholen Anwendungshinweise Messwerte eingehalten F e evtl berkreuzt S DE 9 beachten Rauchen oder Kaffeegenuss DE 19 DI Technische Informationen Technische Informationen D 2 Kundendienst Eine Reparatur des Ger tes darf nur durch den Hersteller oder eine ausdr cklich Aufgetretener M gliche Ursache Abhilfe dazu erm chtigte Stelle erfolgen Fehler Anzeige 0 Start Stop Taste wurde Ger t mit der Start Stop Taste aus Bitte wenden Sie sich an 0 versehentlich wahrend des und wieder einschalten UEBE Medical GmbH Batteriewechsels gedr ckt Zum Ottersberg 9 Messung wurde Starke Unruhen von Puls oder Gegebenenfalls Messung abbre DI EEN Deutschland unterbrochen und durch Bewegung erkannt chen nach 5 Minuten Ruhepause Tel Nr 49 0 9342 924040 Manschette erst Ger t verwirft Messung und neu messen Fax Nr 49 0 9342 924
48. igkeit sch tzen Rel Luftfeuchtigkeit bis 85 8 0 Trocken halten E Hersteller Netzteilangaben Bei Verwendung des optional erh ltlichen Netzteils Schutzklasse Il doppelte Isolierung Innenliegende Sicherung Nur im Haus verwenden GK Ce Polarit t innen Plus DE 25 LEG Allgemeine Bestimmungen Pflege des Ger tes EN 2 Entsorgung e Das Ger t enth lt empfindliche Teile und muss vor starken Temperatur schwankungen Luftfeuchtigkeit Staub und direktem Sonnenlicht gesch tzt at Batterien und technische Ger te geh ren nicht in den Hausm ll werden sondern m ssen bei den entsprechenden Sammel bzw Entsor gungsstellen abgegeben werden e Das Ger t ist nicht stoB oder schlagfest Wir empfehlen nach gr eren St rzen oder Schl gen die Unversehrtheit und Genauigkeit der Displayanzeige ber prufen zu lassen e Das Ger t ist nicht wasserdicht e Falls das Ger t bei der Benutzung verschmutzt verwenden Sie ein weiches trockenes Tuch um das Ger t zu reinigen Verwenden Sie kein Benzin Verd n ner oder andere starke L sungsmittel e Manschette nicht schrubben oder in der Maschine waschen Falls die Man schette bei der Benutzung verschmutzt verwenden Sie zur Reinigung ein syn thetisches Reinigungsmittel und reiben Sie die Oberfl che sanft e Wenn das Ger t ge ffnet war muss es einer messtechnischen Kontrolle durch eine autorisierte Institution unterzogen werden e Vergewiss
49. int orange signifie valeur limite Point rouge signifie valeur lev e I 7 OMS 2003 Pression systolique Pression diastolique il suffit qu une valeur sup rieure valeur inf rieure seule de ces mmHg mmHg valeur soit lev e partir de 140 a partir de 90 millim tre de mercure de 120 a 139 de 80 89 en dessous de 120 en dessous de 80 La classification OMS est stock e en m moire avec les valeurs de pression mesur es elle peut donc tre rappel e au m me titre FR 68 Utilisation de l appareil D 10 Tension diff rentielle La tension diff rentielle a ne pas confondre avec les pulsations cardiaques renseigne sur les propri t s visco lastiques des art res Un syst me vasculaire rigide peut avoir des effets n gatifs sur tout le syst me cardiovasculaire Des tudes ont prouv que le risque cardiovasculaire augmente si la valeur de tension diff rentielle exc de 65 mmHg en permanence Le coeur travaille en deux phases la phase de contraction systole et la phase de rel chement de remplissage ou de repos diastole La diff rence de pression entre la systole et la diastole est appel e tension differentielle ou pression puls e Plus sa valeur est lev e plus le systeme vasculaire est rigide Tension diff rentielle lev e au dessus de 65 mmHg Tension diff rentielle trop lev e de 55 65 mmHg Tension diff rentielle normale en dessous de 55 mmHg Si votre
50. ion date heure est activ e l heure s affiche l cran m me lorsque l appareil est teint fig 3 FR 65 fran ais 2 del Un x 7 Pose du brassard e D gagezla partie sup rieure du bras e Enfilez le brassard autour du bras jusqu ce que le bord inf rieur se trouve 2 3 cm au dessus du coude fig 1 fig 2 e Si le brassard est appliqu autour du bras gauche le tuyau air est pos dans le pli du bras en direction de l appareil et le rep rage de l art re de 4 cm de long se trouve alors automatiquement au dessus du pouls fig 3 e Si le brassard est appliqu autour du bras droit tournez le brassard vers la gauche jusqu ce que le rep rage de l art re soit sur la position du pouls Le tuyau se retrouve alors sur le c t int rieur du bras fig 4 e Serrer le brassard de mani re pouvoir encore introduire deux doigts entre le bras et le brassard Conseil Plier l g rement le bras Le muscle du bras est l g rement tendu ce qui augmente l g rement la circonf rence du bras e A pr sent fermez le brassard gr ce au rabat en serrant le scratch fig 5 e V rifiez que la fl che sur le brassard se trouve dans la zone de marquage situ e sur le bord du 7 brassard FR 66 D Utilisation de l appareil fig 1 Utilisation de l appareil D Poser le bras l g rement tendu sur une table de salle manger Ne bouge pas du
51. is on the pulse position The air hose then runs along the inside of the upper arm Fig 4 The cuff should be tightened to such an extent that 2 fingers can still be inserted between arm and cuff Tip Bend your arm slightly The upper arm muscle is tensioned slightly This slightly increases the circumference of the arm Now pull the free cuff end tight and close the Velcro fastener Fig 5 Check if the measurement arrow on the cuff is wem inside the marking for arm circumference at the edge of the cuff Fig 1 D Operating the unit Operating the unit e Lay your extended and relaxed arm with the cuff on the dining table and do e The determined values of systole diastole and not move it during the measurement do not talk The palm of your hand should pulse and the pulse pressure PP are shown be facing upwards alternately in the display e Connect the cuff connector to the cuff socket on the left hand side of the unit e The unit switches off automatically after approx Make sure the connector is fully inserted into the unit 3 minutes 8 Measuring blood pressure e Switch on the unit by pressing the Start Stop button The following display is visible 9 WHO traffic light function e The automatically controlled inflation process begins once the unit has completed its calibration against the ambient air pressure The unit categorises the blood pressure readings according to the gui
52. it dem behandelnden Arzt abgekl rt werden Deshalb sollten Messergebnisse mit blinkender Pulsanzeige kritisch angesehen und unter g nstigeren Bedingungen wiederholt werden DE 15 D Bedienung des Ger tes 12 Verwendung des Speichers Gemessene Ergebnisse werden automatisch im Speicher abgelegt Der Speicher kann bis zu 60 Ergebnisse und den Durchschnittswert speichern Wenn mehr als 60 Messwerte gespeichert sind wird der lteste Messwert No 60 gel scht um den neuesten Wert No 1 aufzuzeichnen 9 a on ca es en Um Daten abzurufen dr cken Sie die Speicher Taste Der Durchschnittswert der gespeicherten Ergebnisse wird mit A angezeigt die Werte Systole Diastole und Puls sowie der Pulsdruck PP werden abwechselnd im Display sicht bar VI LI IR J i e nu a Durch erneutes Dr cken der Speicher Taste erscheinen die zuletzt gemessenen Werte No 1 Bei aktivierter Da tum Uhrzeit Funktion werden Systole Diastole und Puls abwechselnd mit Speichernummer und Datum angezeigt danach der Pulsdruck PP mit der Uhrzeit LO ei LI en e V 11 VW ii Durch wiederholtes Dr cken der Speicher Taste werden die weiteren Messwerte aufgerufen 1 5 Die gespeicherten Daten sind etwa 30 Sekunden auf dem ZE Display sichtbar Danach schaltet sich das Ger t aus SR i vn d DE 16 Bedienung des Ger tes D Um einzelne Messwerte zu l sch
53. l apparecchio al nostro stabilimento sono a carico del mittente reclami che perverranno non affrancati non saranno accettati da UEBE 4 diritti dell acquirente derivanti dai vizi della cosa nei confronti del venditore ai sensi del 437 del codice civile tedesco non vengono limitati dalla garanzia Nota bene in caso di garanzia allegare sempre lo scontrino di acquisto IT 109 O D ouel e IT 111 IT 110 ouel e 7 24035 001 C 2013 04 E pai UEBE REF 24035 visomat und UEBE sind international gesch tzte Warenzeichen der UEBE Medical GmbH Zum Ottersberg 9 97877 Wertheim Germany Phone 49 0 93 42 92 40 40 Fax 49 0 93 42 92 40 80 E Mail info uebe com Internet www uebe com Technische Anderungen vorbehalten Nachdruck auch auszugsweise untersagt Copyright 2013 UEBE Medical GmbH C 0123 www visomat de e Besser Messen Germany
54. m tre s arr te automatiquement 3 minutes apr s la mesure Ensuite recommencez la mesure La valeur de la pression art rielle n est pas une valeur fixe Chez certains patients elle peut varier de plus ou moins 20 mmHg en quelques minutes FR 63 fran ais CA del Un de D Utilisation de l appareil e Afin d viter d ventuelles diff rences dans les r sultats de mesure entre le bras droit ou le bras gauche et de garantir des r sultats comparables il est recommand de mesurer la pression art rielle toujours sur le m me bras Demandez votre m decin quel bras il vous conseille pour la mesure 4 Mise en marche de l appareil introduire les piles dans le compartiment Pour utiliser l appareil avec le courant de secteur brancher le bloc d alimentation n est pas inclus dans la livraison dans la prise situ e sur le c t droit de l appareil Les piles sont alors automatiquement d sactiv es N utiliser que le bloc d alimentation UEBE type A1 Voir au chapitre pi ces de rechange authentiques et accessoires page FR 77 5 Ins rer changer les piles e Ouvrir le compartiment des piles Retirez le couvercle du compartiment des piles situ sous l appareil e Ins rer les piles Sortez les piles usag es et introduisez les piles neuves Respectez les polarit s Rep rage dans le compartiment piles e Refermer le compartiment des piles Refermez le compartiment des piles en clipsant nouveau le
55. messung entspricht EN 1060 Teil 3 Druckmessung 3 mmHg Pulsmessung 5 Seriennummer Auf dem Ger t befindet sich eine Seriennummer SN welche das Ger t eindeutig identifiziert Stromversorgung Batterietyp 4x 1 5 V Mignon Zellen Alkali Mangan LR 6 oder Lithium FR 6 Lebensdauer Mehr als 800 Messungen in 2 Jahren Optional stabilisiertes Netzteil Type A1 Ausgang 6 VDC Minimum 600 mA Manschette Manschette Type UPW f r Armumfang 23 43 cm Oder optional zus tzlich B gelmanschette Type US f r Armumfang 17 25 cm Betriebsbedingungen Umgebungstemperatur 10 bis 40 C Rel Luftfeuchtigkeit bis 85 nicht kondensierend Luftdruck 700 bis 1040 hPa Lager und Transportbedin Umgebungstemperatur 5 bis 50 C gungen Rel Luftfeuchtigkeit bis 85 nicht kondensierend Luftdruck 700 bis 1040 hPa Luftablassventil Elektronisch geregelt Automatische Abschaltung ca 3 Minuten nach Messende Schutzklasse IP IP 20 Gesch tzt gegen feste Fremdk rper mit Durchmesser ab 12 5 mm kein Schutz gegen Wasser Zu erwartende Betriebsle 5 Jahre bensdauer Klassifikation Interne Stromversorgung durch Batterie DE 22 Technische Informationen D 4 Original Ersatzteile und Zubeh r Folgende Original Ersatzteile bzw Zubeh r k nnen Sie ber den Fachhandel erhal ten Manschette UPW f r Armumfang 23 43 cm Art Nr 2403001 PZN 0044977 B gelmanschette US f r Armumfang 17 25 cm Art Nr 2403005 PZN 004
56. n Ne pas absorber d alcool de nicotine ou de caf ine au moins une heure avant la mesure Avant la mesure attendre au moins 5 minutes au calme afin que la tension descende son niveau normal Cette dur e peut m me varier jusqu une heure selon les efforts r alis s auparavant Prendre la mesure sur le bras nu Les v tements ne doivent en aucun cas g ner la circulation sanguine dans le bras ce qui fausserait la mesure D tendez vous Asseyez vous une table pas une table basse Appuyez votre dos contre le dossier de la chaise Laissez enti rement reposer l avant bras sur la table la paume de la main vers le haut Posez les pieds par terre ne croisez pas les jambes Il est imp ratif de ne pas bouger pendant toute la mesure vitez les mouvements les chocs de parler ou de respirer fort et tout ce qui pourrait influencer le r sultat de la mesure Durant la mesure observez le signal indiquant un pouls irr gulier si n cessaire r p tez la mesure en veillant de meilleures conditions Des r sultats inhabituels sont parfois possibles avec tous les syst mes automatiques de mesure de la pression art rielle V rifiez que vous avez bien respect les consignes d utilisation mentionn es ci dessus Prendre une nouvelle mesure une fois la circulation sanguine de votre bras retourn e son tat normal Pour ce faire reposez vous pendant 3 5 minutes conseil restez assis en effet votre tensio
57. n collegamento alla rete elettrica inserire il connettore dell alimentatore non incluso nella fornitura nella presa posta sul lato destro dell apparecchio Le batterie saranno scollegate automaticamente Utilizzare esclusivamente l alimentatore UEBE tipo A1 Vedere la sezione Ricambi originali e accessori a pagina IT 104 Inserimento sostituzione delle batterie Aprire il vano batterie Togliere il coperchio del vano sul lato inferiore dell apparecchio Inserire la batteria Togliere le batterie vecchie dall apparecchio e inserire quelle nuove Prestare attenzione alla polarit delle batterie contrassegno nel vano durante l inserimento Chiudere il vano batterie Chiudere il vano batterie riposizionando il coperchio sull apparecchio Dal momento in cui compare per la prima volta il simbolo batteria scarica 2 sul display l apparecchio ha autonomia ancora per circa 30 misurazioni Si consiglia nel frattempo di provvedere a sostituire le batterie O D O 2 D Uso dell apparecchio 6 Attivazione e impostazione data ora L apparecchio dispone di una funzione data ora che pu essere attivata all occorrenza Nelle condizioni in cui si trova l apparecchio alla consegna questa funzione disattivata Attivazione della funzione data ora Per attivare la funzione data ora premere il pulsante Start Stop e subito dopo mentre compare la visualizzazione completa del display il tasto Memo
58. n the event of a warranty claim it is essential to attach the proof of purchase EN 55 CA dei Un de Sommaire EN Consignes de s curit 1 Remarques importantes pour le patient 58 2 Remarques techniques importantes 59 D Utilisation de l appareil 1 Description de l appareil 61 2 Affichages des symboles 62 3 Remarques importantes d utilisation 63 4 Mise en marche de l appareil 64 5 Inserer changer les piles 64 6 Activer et r gler la date et l heure 65 7 Pose du brassard 66 8 Mesurer la pression art rielle 67 9 Signalisation OMS 68 10 Tension diff rentielle 69 11 Ondes pulsatoires irr guli res 69 12 Utilisation de la m moire 70 Ce qu il faut savoir sur la pression art rielle 1 La valeur systolique et diastolique de la pression art rielle 72 2 Pourquoi mesurer deux valeurs diff rentes 72 3 Pourquoi mesurer r guli rement la pression arterielle 72 PJ Informations techniques 1 Message d erreur 73 2 Service apr s vente 75 3 Donn es techniques 75 4 Pi ces de rechange originales et accessoires 14 5 Contr le m trologique 78 D G n ralit s 1 Explication des symboles 79 2 Mise rebus 80 D Entretien de l appareil 81 A Garantie 82 Introduction Nous vous remercions d avoir choisi le tensiom tre bras visomat comfort form d nomm appareil dans le pr sent mode d emploi Cet appareil
59. nked A kinked air hose can prevent the cuff from deflating and thereby interrupt the blood flow in the arm for too long e The unit contains small parts which could be swallowed by children It should therefore be kept out of the reach of children at all times The airhose poses a risk of strangulation Please follow instructions regarding the handling of cuff to avoid such risk e If you have had a mastectomy do not measure blood pressure on the side of the body where the breast has been removed together with the lymph nodes from the armpit EN 31 A Safety instructions e Measuring your own blood pressure does not constitute treatment Do not modify of your own accord the dosage of drugs medication prescribed by your doctor e Please refer to the chapter Important instructions for use Page EN 36 before conducting any measurements yourself 2 Important technical details e A constantly good power supply to the unit is necessary for trouble free blood pressure measurements Please use long life alkaline batteries only LR6 Always replace all batteries simultaneously during battery replacement You will need 4 x 1 5 V batteries Rechargeable batteries have a voltage of only 1 2 V and are thus not suitable When using the unit with a mains adapter please use the type A1 mains adapter specially tested for medical devices only Make sure when operating the unit with the mains adapter that the
60. no liquidi nel tubo dell aria Lasciare asciugare completamente IT 108 Garanzia G Prestazioni in garanzia L apparecchio stato realizzato e controllato con la massima cura Ciononostante qualora si riscontrassero vizi al momento della consegna viene concessa una garanzia alle seguenti condizioni 1 Durante il periodo di garanzia di 3 anni dalla data d acquisto elimineremo vizi a nostra discrezione e a nostre spese presso il nostro stabilimento tramite riparazione o fornitura sostitutiva di un apparecchio perfettamente funzionante I costi della rispedizione dell apparecchio al nostro stabilimento sono a carico del mittente reclami che perverranno non affrancati non saranno accettati da UEBE 2 La garanzia non copre il normale consumo delle parti soggette a usura e i danni derivanti dall inosservanza delle istruzioni per l uso da un impiego improprio ad esempio fonti di energia elettrica non idonee rottura batterie con perdite e o dallo smontaggio dell apparecchio da parte dell acquirente La garanzia non copre inoltre eventuali rivendicazioni di danni nei nostri confronti 3 diritti alla garanzia possono essere fatti valere soltanto nel periodo di validit della garanzia presentando lo scontrino di acquisto In caso di garanzia inviare l apparecchio insieme allo scontrino e alla descrizione del reclamo a UEBE Medical GmbH Service Center Zum Ottersberg 9 97877 Wertheim Germania I costi della rispedizione del
61. ntie ne justifie aucune r clamation de dommages et int r ts Les r clamations sous garantie ne sont valables que pendant la p riode de garantie et sur pr sentation du bon d achat En cas de r clamation sous garantie retourner l appareil accompagn du bon d achat ainsi que d une description du vice l adresse suivante UEBE Medical GmbH Service Center Zum Ottersberg 9 97877 Wertheim Allemagne Les frais de renvoi l usine sont la charge de l exp diteur Les retours de livraison pour r clamation non affranchis ne seront pas accept s par UEBE En cas de r clamation pour vice les droits contractuels de l acheteur contre le vendeur conform ment l article 437 du Code Civil allemand ne sont pas restreints par la garantie Remarque pour une r clamation sous garantie n oubliez pas de joindre le bon d achat FR 82 Indice EN Avvertenze di sicurezza 1 Avvertenze importanti per il paziente 85 2 Avvertenze tecniche importanti 86 D Uso dell apparecchio 1 Descrizione dell apparecchio 88 2 Indicatori di controllo 89 3 Avvertenze importanti per l uso 90 4 Messa in funzione dell apparecchio 91 5 Inserimento sostituzione delle batterie 91 6 Attivazione e impostazione data ora 97 7 Applicazione del bracciale 93 8 Misurazione della pressione arteriosa 94 9 Funzione semaforo OMS 95 10 Pressione del polso 96 11 Frequenza del
62. nutzer helfen das digitale Blutdruckmessger t sicher und effizient anzuwenden Sie muss mit dem Produkt aufbewahrt und ggf weiter gegeben werden Das Ger t muss entsprechend den in dieser Anleitung enthaltenen Verfahren ver wendet werden und darf nicht f r andere Zwecke eingesetzt benutzt werden Lesen Sie diese Anleitung sorgf ltig durch bevor Sie das Ger t verwenden DE 3 A Sicherheitshinweise 1 Wichtige Patientenhinweise e Das Ger t ist auf die nichtinvasive Messung des systolischen und diastolischen Blutdrucks am Oberarm sowie die Bestimmung der Pulsrate bei Erwachsenen ausgerichtet d h ab Alter 15 und h her Blutdruckmessungen an Kindern be d rfen besonderer Kenntnisse Konsultieren Sie Ihren Arzt wenn Sie den Blut druck eines Kindes messen m chten Auf keinen Fall darf das Ger t bei einem S ugling angewendet werden e Die mitgelieferte Standardmanschette ist auf einen Oberarmumfang von 23 43 cm ausgelegt F r Armumfange von 17 25 cm ist optional eine kleinere Manschette erh ltlich siehe Seite DE 23 Zubeh r e Die Messergebnisse von automatisch messenden Blutdruckmessger ten k n nen durch Schwangerschaft Herzrhythmusst rungen oder Arteriosklerose verf lscht werden F hren sie eine Blutdruck Selbstkontrolle in Absprache mit Ihrem Arzt durch e Auf keinen Fall darf die Manschette auf oder ber einer kritischen Stelle z B Wunde Aneurysma etc angelegt werden Verletzungsgefahr Eine Ve
63. o fino in fondo nella presa 8 Misurazione della pressione arteriosa e Accendere l apparecchio premendo il tasto Start Stop Sul display compare quanto segue e Dopo che l apparecchio ha eseguito la compensazione rispetto alla pressione atmosferica ambientale inizia il processo di pompaggio automatico e Il bracciale viene gonfiato alla pressione necessaria Il simbolo lampeggia sul display e Successivamente con lo sgonfiaggio inizia il processo di misurazione vero e proprio Il simbolo lampeggia sul display ed entra in funzione un segnale acustico per la frequenza del polso e La fine della misurazione indicata da un segnale acustico prolungato II bracciale si sgonfia automaticamente IT 94 Uso dell apparecchio e valori rilevati di sistole diastole e polso nonch la pressione del polso PP Puls Pressure vengono visualizzati alternativamente sul display e Dopo ca 3 minuti l apparecchio si spegne automaticamente 9 Funzione semaforo OMS L apparecchio classifica i valori della pressione sanguigna misurati in base alle direttive dell Organizzazione Mondiale della Sanit OMS Sulla base dei campi colorati accanto al display possibile leggere la classificazione per ogni misurazione Il punto inferiore verde significa valore normale punti intermedi giallo significano valore limite punti superiori rosso significano pressione alta OMS 2003 Pressione
64. o scosse elettriche TIPO BF TF Condizioni di conservazione e di trasporto Temperatura ambiente da 5 a 50 C Proteggere dall umidit NE Umidit atmosferica rel fino all 85 gem Conservare in luogo asciutto ul Produttore Dati dell alimentatore In caso di utilizzo dell alimentatore disponibile separatamente Ol Classe di protezione Il doppio isolamento SI Fusibile all interno Utilizzare solo in casa Ce Polarit interna negativa IT 106 IT 107 O S DES Manutenzione dell apparecchio e L apparecchio contiene parti sensibili e deve essere protetto dalle forti variazioni di temperatura dall umidit dell aria dalla polvere e dall irradiazione solare diretta e L apparecchio non a prova d urto Consigliamo di far controllare l integrit e la precisione del display dopo urti di una certa entit e L apparecchio non impermeabile e Qualora l apparecchio dovesse sporcarsi durante l utilizzo si raccomanda di pulirlo esclusivamente con un panno morbido e asciutto Non utilizzare benzina diluenti o altri solventi aggressivi e Non strofinare n lavare in lavatrice il bracciale Qualora il bracciale dovesse sporcarsi durante l utilizzo si raccomanda di pulirlo con un detergente sintetico strofinandone delicatamente la superficie e Se l apparecchio viene aperto necessario sottoporlo ad un controllo metrologico da parte di un istituto autorizzato e Assicurarsi che non si infiltri
65. on the artery walls caused by the heart contracting is termed systolic The pressure in the ensuing relaxation phase when the heart refills with blood is termed diastolic During daily measurement you determine both values 2 Reasons for measuring different values Our blood pressure responds to internal and external influences like a sensitive measuring instrument It can be affected by even slight changes This explains why often values measured with the doctor or pharmacist are higher than those measured at home in the environment you are used to Changes in the weather climate changes or physical or psychological stress can have effects as well 3 Why you should measure blood pressure regularly Even the time of day has an influence on your blood pressure During the day the values are generally higher than during the periods of rest at night One off and irregular measurements therefore say little about your actual blood pressure A reliable assessment is possible only when measurements are taken regularly Discuss the measurement values with your doctor EN 45 Technical information 1 Failure and error messages Failure Possible cause Corrective action encountered Display Err Excessive cuff pressure Cuff Repeat measurement 300 inflated to maximum due to Do not move arm movement of the arm or body Do not talk The hose may be kinked or the Check that hose with air connector blocked air connector
66. or also referred to in the following as the unit This unit is recommended to patients with unstable blood pressure for measuring their blood pressure at home and for therapy support visomat comfort form uses the oscillometric method for measuring blood pressure and pulse rate on the upper arm The cuff is first placed as shown in the illustration on the cuff on the upper arm and then connected to the unit When the Start Stop button is pressed the system starts to build up pressure automatically Within a very short space of time the unit records the small oscillations within the cuff which occur owing to expansion and contraction of the arteries in the arm heartbeat The automatic build up of pressure usually stops approx 40 mmHg above the systolic value fuzzy logic Then the actual measurement process starts while the cuff is being deflated The amplitude of each pressure wave is measured in millimetres of mercury mmHg converted and displayed in the LCD as a digital value As well as indicating systole diastole and pulse the unit offers a date time function and additional displays for determining irregular pulses and pulse pressure Irregular pulses may be an indication of an irregular heartbeat but also of restlessness during the measurement Pulse pressure provides an indication of the stretchability of the blood vessels A memory stores the last 60 measurement results in each case for comparison These instructions are inten
67. polso irregolare 96 12 Uso della memoria 97 Cosa necessario sapere sulla pressione arteriosa 1 Valori della pressione arteriosa sistolica e diastolica 99 2 Perch misurare diversi valori 99 3 Perch misurare regolarmente la pressione arteriosa 99 gt Informazioni tecniche 1 Messaggi d errore 100 2 Assistenza Clienti 102 3 Dati tecnici 102 4 Ricambi originali e accessori 104 5 Controllo metrologico 105 D Disposizioni generali 1 Dichiarazione di conformit 106 2 Smaltimento 107 D Manutenzione dell apparecchio 108 dl Garanzia 109 O O 2 Introduzione Grazie per avere scelto lo sfigmomanometro da braccio visomat comfort form di seguito denominato anche l apparecchio Questo apparecchio consigliato a pazienti con pressione sanguigna instabile per l automonitoraggio e come supporto alla terapia visomat comfort form misura sul braccio la pressione sanguigna e i battiti del polso utilizzando il metodo oscillometrico Applicare dapprima il bracciale sulla parte superiore del braccio come illustrato sul bracciale e poi collegarlo all apparecchio Premendo il tasto Start Stop l apparecchio inizia a generare automaticamente pressione In poco tempo l apparecchio registra le piccole oscillazioni all interno del bracciale causate dall estensione e dalla contrazione delle arterie nel braccio battito cardiaco La compressione automatica cessa generalmente a circa 40 mmHg ol
68. r ck gesendete Reklamationen werden von UEBE nicht angenommen 4 Die gesetzlichen M ngelanspr che des K ufers gegen den Verk ufer gem 8 437 BGB werden durch die Garantie nicht eingeschr nkt Bitte beachten Sie Im Garantiefall bitte unbedingt den Kaufbeleg bei legen DE 28 Table of contents D Safety instructions 1 Important patient instructions 31 2 Important technical details 32 D Operating the unit 1 Unit description 34 2 Control displays 35 3 Important instructions for use 36 4 Initial operation of the unit ER 5 Inserting replacing batteries 37 6 Activating and setting the date time 38 7 Attaching the cuff 39 8 Measuring blood pressure 40 9 WHO traffic light function 41 10 Pulse pressure 42 11 Irregular pulse waves 42 12 Using the memory 43 What you should know about blood pressure 1 Systolic and diastolic blood pressure values 45 2 Reasons for measuring different values 45 3 Why you should measure blood pressure regularly 45 gt Technical information 1 Failure and error messages 46 2 Customer service 47 3 Technical data 47 4 Original spare parts and accessories 50 5 Metrological inspection 51 D General provisions 1 Explanation of symbols 52 2 Disposal 53 D Maintaining the unit 54 A Warranty 55 Introduction Thank you for choosing the visomat comfort form upper arm blood pressure monit
69. r Manschette 2 3 cm ober a spell halb der Armbeuge liegt Bild 1 Bild 2 e Bei Anwendung am linken Arm l uft der Luft schlauch in der Mitte der Armbeuge zum Ger t damit ist die 4 cm lange Arterienmarkierung auto matisch mittig ber der Pulsstelle platziert Bild 3 e Bei Anwendung am rechten Arm muss die Man schette so weit nach links verdreht werden bis die Arterienmarkierung auf der Pulsstelle liegt Der Luftschlauch verl uft dann an der Innenseite des Oberarms Bild 4 e Die Manschette soll so fest anliegen dass noch 2 Finger zwischen Arm und Manschette passen Tipp winkeln Sie den Arm leicht an der Oberarmmuskel wird leicht angespannt dadurch nimmt der Umfang des Armes leicht zu e Ziehen Sie jetzt das freie Manschettenende straff und schlie en den Klettverschluss Bild 5 e Pr fen Sie ob der Messpfeil auf der Manschette innerhalb der Markierung f r Armumfang am bah Manschettenrand liegt DE 12 B Bedienung des Ger tes Bedienung des Ger tes D e Legen Sie den Arm mit der Manschette locker ausgestreckt auf einen Esstisch und halten Sie ihn w hrend der Messung unbedingt ruhig sprechen Sie nicht Die Handinnenfl che weist nach oben e Verbinden Sie den Stecker der Manschette mit dem Manschettenanschluss an der linken Seite des Ger tes Stellen Sie sicher dass der Stecker ganz in das Ger t eingesteckt ist 8 Blutdruck messen e Das Ger t durch Dr cken
70. ra per l arteria lunga 4 cm venga a trovarsi automaticamente in posizione centrale al di sopra del punto di misurazione del polso Figura 3 Figura 1 e Se lo si usa sul braccio destro il bracciale deve essere ruotato a sinistra fino a far arrivare la marcatura per l arteria sul punto di misurazione del polso Il tubo dell aria si trover cos sul lato interno della parte superiore del braccio Figura 4 e Stringere il bracciale in modo che sia ancora possibile infilare 2 dita tra il braccio e il bracciale Suggerimento piegare leggermente il braccio il muscolo brachiale si tende leggermente in questo modo la circonferenza del braccio aumenta leggermente Figura 3 Figura 4 e Tirare quindi l estremit libera del bracciale in modo che si tenda completamente e chiudere il velcro Figura 5 e Verificare che la freccia indicata sul bracciale si trovi all interno della marcatura per la ka circonferenza del braccio che si trova sul bordo S Za del bracciale Figura 5 IT 93 O D O S D Uso dell apparecchio e Stendere sul tavolo il braccio senza tenderlo troppo con il bracciale allacciato e tenerlo assolutamente fermo durante la misurazione non parlare Il palmo della mano deve essere rivolto verso l alto e Inserire il connettore del bracciale nella corrispondente presa posta sul lato sinistro dell apparecchio Assicurarsi che il connettore sia inserit
71. rant la mesure Ne parlez pas La paume de la main est tourn e vers le haut Brancher le tuyau du brassard dans la connexion du brassard sur le c t gauche de l appareil V rifier que le tuyau est bien enfonc dans l appareil Mesurer la pression art rielle 0 86786 Allumez l appareil en appuyant sur la touche Start Stop Les symboles suivants apparaissent l cran Apr s avoir effectu une mise au point en fonction de la pression atmosph rique le gonflage commence automatiquement Le brassard gonfle automatiquement jusqu la compression n cessaire Le symbole A clignote l cran Puis le brassard se d gonfle et l appareil commence la mesure Le symbole clignote des bips sonores retentissent au rythme du pouls La fin de la mesure est annonc e par une longue tonalit le brassard se degonfle enti rement FR 67 fran ais CA del Un de Utilisation de l appareil e Les valeurs de pression systolique diastolique et du pouls ainsi que la pression diff rentielle PP puls pressure s affichent en alternance e L appareil s teint automatiquement au bout de 3 minutes 9 Signalisation OMS L appareil classe les valeurs de pression mesur es selon les directives de l Organisation Mondiale de la Sant OMS Les points de couleur cot de l cran vous aide lire la classification apr s chaque mesure Point vert signifie valeur normale Po
72. re discussi con il medico Controllare le condizioni e ripetere la misurazione Seguire i consigli per l uso riportati a pagina IT 90 Informazioni tecniche D Errore indicato Visualizzazione 0 0 La misurazione stata interrotta e il bracciale si sgonfia e si rigonfia Dopo l accensione non compare nulla sul display valori misurati sono estremamente alti o bassi Durante la sostituzione delle batterie stato premuto involontariamente il tasto Start Stop In caso di forte irregolarit del polso o in caso di movimenti l apparecchio non considera la misurazione effettuata e ne inzia una nuova Ci sono stati dei movimenti durante la misurazione Batterie inserite in modo non Controllate la posizione delle corretto batterie Batterie scariche Sostituite le batterie Vano portabatterie sporco Pulite il vano portabatterie La misurazione Batterie scariche Sostituite le batterie stata interrotta stata mantenuta la posizione corretta per la misurazione La misurazione stata eseguita con la calma richiesta Spegnete e riaccendere l apparecchio con il tasto Start Stop Eventualmente interrompete la misurazione e ripeterla dopo 5 minuti di pausa Eventualmente interrompete la misurazione e ripeterla dopo 5 minuti di pausa Ripetete la misurazione facendo attenzione alla corretta posizione del corpo Non muovete il braccio e non parlate Ripetete la misurazione dopo circa
73. reil se trouve un num ro de s rie SN Ce num ro permet d identifier l appareil Alimentation Type de piles 4 x 1 5 V Mignon LR 6 type AA Alcali lectrique mangan se ou lithium FR 6 Dur e de vie plus de 800 mesures en 2 ans En option bloc d alimentation type A1 sortie 6 VDC minimum 600 mA Brassard Brassard type UPW circonf rence de bras 23 43 ou en option et suppl ment brassard type US pour circonf rence de bras 17 25 cm Temp rature ambiante 10 40 C Humidit relative de l air jusqu 85 non condensant Pression de l air de 700 a 1040 hPa Conditions de Temp rature ambiante 5 50 C Humidit relative de transport et de l air jusqu 85 non condensant Pression de l air de stockage 700 1040 hPa Valve de purge Contr le lectronique Coupure automatique env 3 minutes apr s la fin de la mesure Conditions de fonctionnement Classe de protection IP 20 Protection contre les particules solides d un diam tre L de 12 5 mm pas de protection contre l eau Dur e de vie pr vue 5 ans de l appareil Classification Alimentation lectrique interne par pile FR 76 Informations techniques D 4 Pi ces de rechange authentiques et accessoires francais Vous pouvez vous procurer les pi ces de rechange et les accessoires authentiques dans les magasins sp cialis s Brassard UPW circonf rence de bras 23 43 cm R f 2403001 PZN 0044977 Brassard U
74. rsorgung durch einen intravaskularen Zugang Infusion k nnte unter Umst nden unter brochen werden e Stellen Sie sicher dass der Luftschlauch nicht geknickt wird Ein geknickter Luftschlauch kann das Entl ften der Manschette verhindert und damit den Blutfluss im Arm zu lange unterbrechen e Das Ger t enth lt Kleinteile die von Kindern verschluckt werden k nnten Ger t daher nicht unbeaufsichtigt Kindern berlassen Durch den Luftschlauch besteht die Gefahr des Strangulierens Beachten Sie die Hinweise zur Hand habung der Manschette um dieses Risiko zu vermeiden e Auf der Seite einer Brustamputation bei gleichzeitiger Entfernung der Lymph knoten der Achselh hle darf keine Blutdruckmessung erfolgen DE 4 Sicherheitshinweise A Selbstmessung bedeutet noch keine Therapie Ver ndern Sie auf keinen Fall von sich aus die vom Arzt verschriebene Dosierung der Arzneimittel Beachten Sie vor Ihren Selbstmessungen das Kapitel Wichtige Anwendungs hinweise Seite DE 9 Wichtige technische Hinweise Eine gleich bleibend gute Stromversorgung Ihres Ger tes ist f r st rungsfreies Blutdruckmessen notwendig Verwenden Sie nur langlebige Alkaline Batterien LR6 Tauschen Sie beim Batteriewechsel immer alle Batterien gleichzeitig aus Sie ben tigen 4 x 1 5 Volt Batterien Wieder aufladbare Batterien haben nur 1 2 Volt Spannung und sind deshalb ungeeignet Bei Anwendung mit Netzteil verwenden Sie bitte nur da
75. ry Allo stesso modo possibile disattivare la funzione in qualsiasi momento Impostazione data ora Sul display compare dapprima il numero dell anno a quattro cifre Figura 1 Premendo il tasto Memory possibile impostare l anno Premendo il pulsante Start Stop l anno selezionato viene confermato e si passa all impostazione della data Impostare il mese con il tasto Memory e confermarlo con Figura 1 il pulsante Start Stop Procedere allo stesso modo per l impostazione del giorno dell ora e dei minuti Figura 2 Figura 3 1 1 Modifica data ora Per modificare la funzione data ora togliere una batteria e attendere fino a quando non si spegner il display Sar quindi possibile reimpostare la data e l ora Figura 2 Disattivazione della funzione data ora Per disattivare la funzione data ora premere il pulsante Start Stop e subito dopo il tasto Memory Con la funzione data ora attivata l ora viene visualizzata sul display anche ad apparecchio spento Figura 3 IT 92 Uso dell apparecchio B 7 Applicazione del bracciale e Liberare la parte superiore del braccio e infilare il bracciale sul braccio fino a quando il bordo inferiore del bracciale si trova a 2 3 cm al a aa di sopra dell incavo del braccio Figura 1 Figura 2 A e Se la misurazione avviene sul braccio sinistro il tubo dell aria deve essere posizionato al centro dell incavo del braccio in direzione dell apparecchio in modo che la marcatu
76. rythme r gulier La pression du sang exerc e sur les parois art rielles pendant la phase de contraction du coeur est appel e systole La pression g n r e pendant la phase de rel chement lorsque le coeur se remplit de nouveau de sang est appel e diastole La mesure quotidienne de la pression art rielle permet de calculer les pressions systolique et diastolique 2 Pourquoi mesurer ces deux valeurs diff rentes La pression art rielle varie beaucoup en fonction de certains facteurs externes et internes un peu comme un instrument de mesure sensible Les moindres changements peuvent influer sur la pression art rielle Ceci explique pourquoi les mesures effectu es chez le m decin ou le pharmacien peuvent tre plus lev es que celles effectu es la maison dans un environnement familier Les changements m t orologiques soudains les changements climatiques le stress physique et mental sont galement des facteurs qui influencent la pression art rielle 3 Pourquoi mesurer r guli rement la pression art rielle La pression art rielle varie au cours de la journ e et le moment auquel vous effectuez la mesure influe donc sur le r sultat La pression art rielle est g n ralement plus lev e dans la journ e que la nuit p riode de repos Un r sultat irr gulier et exceptionnel ne permet donc pas de tirer des conclusions d finitives sur la pression art rielle Pour valuer la pression art rielle de fa on
77. s speziell f r Medi zinprodukte gepr fte Netzteil Type A1 Stellen Sie beim Betrieb mit Netzteil sicher dass das Ger t jederzeit vom Stromnetz getrennt werden kann Wird das Ger t l ngere Zeit nicht benutzt entfernen Sie bitte die Batterien Grunds tzlich kann jede Batterie auslaufen Das Ger t darf nur mit Originalersatzteilen betrieben werden Bei Sch den durch fremdes Zubeh r erlischt die Garantie Die Anwendung dieses Ger tes in der N he von tragbaren Telefonen Mikro wellen oder sonstigen Ger ten mit starken elektromagnetischen Feldern kann zu Fehlfunktionen f hren Halten Sie bei der Benutzung einen Mindestabstand von 3 m zu solchen Ger ten ein Die Anzeige der Pulsfrequenz ist nicht geeignet zur Kontrolle der Frequenz von Herzschrittmachern Herzschrittmacher und Blutdruckmessger t haben in ihrer Wirkungsweise keinen Einfluss aufeinander DE 5 A Sicherheitshinweise e ffnen oder ver ndern Sie auf keinen Fall das Ger t oder die Manschette dies ist ein Medizinprodukt Ausgenommen Batteriewechsel Wenn das Ger t ge ffnet war muss es einer messtechnischen Kontrolle durch eine autorisierte Institution unterzogen werden e Die Manschette darf nur am Arm aufgepumpt werden e Bitte halten Sie die vorgesehenen Betriebsbedingungen zur Messung ein Siehe Technische Daten Seite DE 21 e Der Aufpump und Messvorgang kann durch Dr cken der Start Stop Taste oder durch das Entfernen der M
78. serie Sur l appareil se trouve un num ro de s rie SN Ce num ro permet d identifier l appareil Alimentazione Tipo di batterie 4 x 1 5 V stilo alcaline al manganese LR6 o al litio FR 6 durata oltre 800 misurazioni in 2 anni Opzionale alimentatore stabilizzato tipo A1 uscita 6 VDC minimo 600 mA Bracciale Bracciale tipo UPW per circonferenza del braccio compresa tra 23 e 43 cm oppure su richiesta oppure optional in pi bracciale tipo US per circonferenza del braccio compresa tra 17 e 25 cm Temperatura ambiente tra i 10 e i 40 C umidit relativa dell aria max 85 non condensante Pressione dell aria tra i 700 e i 1040 hPa Condizioni di Temperatura ambiente tra i 5 e i 50 C umidit relativa conservazione e di dell aria max 85 non condensante Pressione dell aria trasporto tra i 700 e i 1040 hPa superiore a 12 5 mm nessuna protezione contro l acqua IT 103 Condizioni d uso O 2 S O 2 D Informazioni tecniche 4 Ricambi originali e accessori seguenti ricambi originali e o accessori sono reperibili presso i rivenditori specializzati Bracciale UPW per circonferenza del braccio compresa tra 23 e 43 cm Articolo n 2403001 PZN 0044977 Bracciale US per circonferenza del braccio compresa tra 17 e 25 cm Articolo n 2403005 PZN 0044960 Alimentatore tipo A1 Codice 2401020 PZN 3558547 Con riserva di modifiche tecniche Produttore UEBE Medical GmbH Zum O
79. sistolica Pressione diastolica sufficiente valore massimo valore minimo se gia uno mmHg mmHg dei valori aumentato millimetri di mercurio da 120 fino a 139 da 80 fino a 89 La classificazione secondo l OMS viene memorizzata con i valori della misurazione e insieme a questi pu essere richiamata dalla memoria IT 95 O D O D Uso dell apparecchio 10 Pressione del polso La pressione del polso da non confondere con il battito del polso fornisce informazioni sull elasticit dei vasi sanguigni Un sistema vascolare rigido pu influire negativamente sul sistema cardiocircolatorio Studi dimostrano che il rischio cardiovascolare aumenta se il valore della pressione del polso costantemente maggiore di 65 mmHg Il cuore funziona in due fasi la fase di contrazione fase di espulsione sistole e la fase di dilatazione fase di riempimento o fase di riposo diastole La differenza di pressione tra sistole e diastole viene denominata pressione del polso o ampiezza del polso Pi elevata la pressione del polso pi rigidi sono i vasi Pressione del polso elevata superiore a 65 mmHg Pressione del polso aumentata da 55 a 65 mmHg inferiore a 55 mmHg Pressione del polso normale Se la pressione del polso dovesse rimanere a lungo oltre 55 mmHg si consiglia di consultare il proprio medico curante 11 Frequenza del polso irregolare Se dopo una misurazione lampeg
80. ss h ufig beim Arzt oder Apotheker gemessene Werte h her sind als jene die Sie zu Hause in gewohnter Umgebung erhalten Aber auch Wet terumschwung Klimawechsel k rperliche und seelische Belastungen k nnen sich auswirken 3 Warum regelm ig Blutdruck messen Auch die Tageszeit hat einen Einfluss auf die H he des Blutdruckes Tags ber sind die Werte meist h her als w hrend der Ruhephasen in der Nacht Einmalige und unregelm ige Messungen sagen daher kaum etwas ber den tats chlichen Blut druck aus Eine zuverl ssige Beurteilung ist nur m glich wenn regelm ig Einzel messungen durchgef hrt werden Besprechen Sie die Messwerte mit Ihrem Arzt DE 18 Technische Informationen 1 Fehler und Errormeldungen Aufgetre M gliche Ursache Abhilfe tener Fehler Anzeige Err Manschetten berdruck Durch Wiederholen Sie die Messung 300 Bewegen des Arms bzw des Bewegen Sie den Arm nicht K rpers wurde die Manschette bis Sprechen Sie nicht zum Maximum aufgepumpt Evtl ist der Schlauch geknickt oder Schlauchleitung mit Luftstecker der Luftstecker verstopft auf Durchg ngigkeit berpr fen Anzeige Messfehler Messung konnte wegen Wiederholen Sie die Messung Err 1 Bewegen des Arms bzw des Kor Bewegen Sie den Arm nicht pers nicht durchgefuhrt werden Sprechen Sie nicht Anzeige Aufpumpfehler Druck wird zu Sitz des Luftsteckers berpr fen Err 2 schnell oder zu langsam aufgebaut Messung w
81. t ou autre d tergent agressif e Ne pas lessiver le brassard ni le laver en machine Si vous devez nettoyer un brassard sale utilisez un agent d tergent synth tique et frotter la surface avec pr caution e Lorsque l appareil a t ouvert il doit subir un contr le m trologique de mesure par un service technique agr e Assurez vous qu aucun liquide ne p n tre dans le tuyau d air Laisser bien s cher FR 80 FR 81 CA del Un x G Garantie Garantie du fabricant L appareil a t fabriqu et contr l avec le plus grand soin Cependant pour le cas d une constatation de vice la livraison nous accordons une garantie aux conditions suivantes 1 Durant la p riode de garantie de 3 ans a compter de la date d achat nous nous r servons le droit d liminer les vices notre convenance et nos frais dans notre usine en effectuant soit une r paration soit le remplacement de l appareil par une unit en parfait tat de marche Les frais de renvoi l usine sont la charge de l exp diteur Les retours de livraison pour r clamation non affranchis ne seront pas accept s par UEBE La garantie ne couvre pas l usure des pi ces d usure ni les dommages caus s par un non respect du mode d emploi par un maniement non conforme par exemple alimentation lectrique non appropri e cassure piles non tanches et ou par un d montage de l appareil effectu par l acheteur Par ailleurs la gara
82. tole and diastole is called the pulse pressure or pulse amplitude The higher the pulse pressure the harder the vessels High pulse pressure above 65 mmHg Increased pulse pressure 55 to 65 mmHg Normal pulse pressure below 55 mmHg If your pulse pressure is permanently above 55 mmHg consult your doctor 11 Irregular pulse waves If the symbol for irregular pulse waves flashes after a measurement the unit has recorded irregular pulses during the measurement This can be set off by an irregular heartbeat arrhythmia disturbances caused by movement talking or even breathing in deeply The symbol is stored with the respective measurement If the symbol appears more frequently this may be caused by an irregular heartbeat and must be discussed with your doctor Measurement results accompanied by flashing pulse displays should therefore be viewed as critical and repeated under more favourable conditions EN 42 Operating the unit D 12 Using the memory Measured results are automatically stored in the memory The memory can store up to 60 results and the average value When more than 60 measured values have been stored the oldest value No 60 is deleted to allow the latest value No 1 to be recorded 9 29 i on I e em em RK KEE LC LI Press the Memory button to call up data The average value of the stored results is displayed with A the values for systole diastole and pulse and th
83. tre il valore sistolico Fuzzy logic Successivamente con lo sgonfiaggio inizia il processo di misurazione vero e proprio L ampiezza di ogni onda di pressione misurata in millimetri di mercurio mmHg convertita e visualizzata come valore digitale sul display LCD Oltre alle indicazioni di sistole diastole e polso l apparecchio offre un indicatore supplementare per rilevare le pulsazioni irregolari e la pressione del polso e ora anche l indicazione della data e dell ora Tale irregolarit pu essere indicativa di disturbi del ritmo cardiaco ma pu anche essere dovuta ad agitazione durante la misurazione La pressione del polso fornisce indicazioni sull elasticit dei vasi sanguigni Una memoria memorizza gli ultimi 60 risultati per consentire il confronto Queste istruzioni si prefiggono di aiutare l utente a utilizzare lo sfigmomanometro digitale in modo sicuro ed efficiente e devono essere conservate ed eventualmente cedute insieme al prodotto L apparecchio deve essere utilizzato seguendo le procedure descritte nelle presenti istruzioni e non deve essere utilizzato per scopi diversi Leggere attentamente le presenti istruzioni prima di utilizzare l apparecchio IT 84 Avvertenze di sicurezza A 1 Avvertenze importanti per il paziente e Questo apparecchio stato concepito per la misurazione non invasiva della pressione arteriosa sistolica e diastolica sulla parte superiore del braccio e per la determinazione della frequen
84. tre plac sur un endroit critique par ex une plaie un an vrisme etc Risque de blessure Selon les circonstances l alimentation par voie intraveineuse perfusion pourrait tre interrompue e Assurez vous que le tuyau d air n est pas pli Un tuyau pli peut emp cher le d gonflage du brassard et interrompre ainsi trop longtemps le flux sanguin dans le bras e L appareil contient des petites pi ces qui pourraient tre ing r es par les enfants Ne pas laisser l appareil la port e des enfants Risque de strangulation avec le tuyau d arriv e d air Afin d viter tout risque respectez les consignes de manipulation du brassard e Dans le cas d une ablation du sein et des ganglions lymphatiques ne pas mesurer la pression art rielle au bras du c t de l op ration FR 58 Consignes de s curit A L automesure de la tension ne constitue aucun traitement Aussi ne modifiez en aucun cas le dosage des m dicaments prescrits par votre m decin Avant l automesure lisez le chapitre remarques importantes d utilisation page FR 63 Remarques techniques importantes Afin d effectuer les mesures sans probl me l appareil doit tre constamment aliment en nergie N utilisez que des piles alcalines longue dur e LR6 Remplacez toutes les piles en m me temps 4 piles de 1 5 Volt sont n cessaires Les piles rechargeables ne poss dent qu une tension de 1 2 Volt et sont donc inappropri es En c
85. ttersberg 9 97877 Wertheim Germania IT 104 Informazioni tecniche D 5 Controllo metrologico ex taratura In generale si consiglia un controllo metrologico periodico ogni 2 anni In Germania gli esercizi specializzati sono tuttavia tenuti ad eseguirla in conformit alla disposizione tedesca per i gestori di prodotti medicali Questo controllo pu essere eseguito da UEBE Medical GmbH da un ente competente in materia di misurazioni o dal centro di manutenzione autorizzato A questo proposito si prega di attenersi alle disposizioni nazionali Su richiesta le autorit competenti o i centri di manutenzione autorizzati possono ottenere dal produttore un certificato di controllo metrologico Attenzione senza l autorizzazione del produttore non consentito eseguire modifiche sull apparecchio ad esempio aprirlo tranne la sostituzione delle batterie IT 105 O 2 S Ey Disposizioni generali Disposizioni generali EN x 1 Dichiarazione di conformit 2 Smaltimento Batterie e apparecchi tecnici non sono rifiuti domestici ma devono zZ Questo prodotto conforme alla direttiva 93 42 CEE del Consiglio essere consegnati a centri di raccolta e smaltimento specializzati del 5 settembre 2007 sui prodotti medicali che entrato in vigore 0123 il 21 Marzo 2010 e reca il marchio CE 0123 T V S D Product Service GmbH Attenersi alle istruzioni per l uso Grado di protezione contr
86. un contr le m trologique doit tre effectu par un institut agr Brassard e Le brassard est uniquement destin tre gonfl sur le bras e Veuillez respecter les conditions d utilisation pr vues pour la mesure Se reporter aux d tails techniques page FR 75 e inflation et la proc dure de mesure peuvent tre interrompues en appuyant sur le bouton Marche Arr t ou en retirant le brassard L appareil arr te l inflation et le brassard se degonfle 5 Affichage des messages Prise d air fiche d air Touche Memory rappel des valeurs Tuyau air sauvegard es Rep rage art res Prise pour cable d alimentation Rep rage blanc pour circonf rence Touche Start Stop du bras Bo tier piles Couvercle des piles Brassard amovible Fl che de rep re pour la circonf rence du bras FR 60 FR 61 CA dei Un de D Utilisation de l appareil 2 Affichages des symboles Case m moire ou date heure D gontlage du brassard SYS Systole Contr le du pouls resp detection des pulsations irr guli res DIA Diastole L appareil pompe PUL 1 min pouls Nombre de pulsations par minutes Classement OMS Page FR 68 Indication de contr le de piles Reconnaissance de la m moire Signal de dysfonctionnement et signal d erreur Page FR 73 Err 300 1 2 FR 62 Utilisation de l appareil D 3 Remarques importantes d utilisatio
87. za del polso negli adulti vale a dire nei soggetti dai 15 anni in poi Le misurazioni della pressione arteriosa nei bambini richiedono conoscenze particolari Consultare il medico se si desidera misurare la pressione arteriosa di un bambino Non utilizzare in alcun caso l apparecchio su un neonato e bracciale standard in dotazione adatto a una circonferenza della parte superiore del braccio di 23 43 cm Per circonferenze del braccio di 17 25 cm disponibile come optional un bracciale pi piccolo IT 104 Accessori e risultati di misurazione degli sfigmomanometri automatici possono risultare alterati in caso di gravidanza disturbi del ritmo cardiaco o arteriosclerosi Eseguire un autocontrollo della pressione arteriosa dietro consulto con il medico e Non applicare mai il bracciale su punti critici come ad es Ferite aneurismi ecc Pericolo di lesioni In alcune circostanze l alimentazione per via intravascolare infusione potrebbe essere interrotta e Assicuratevi che il tubo dell aria non sia piegato Un tubo piegato potrebbe impedire lo sgonfiamento del bracciale interrompendo cos troppo a lungo il flusso ematico nel braccio e L apparecchio contiene componenti di piccole dimensioni che potrebbero essere ingerite dai bambini Tenere pertanto l apparecchio al di fuori della loro portata Il tubo dell aria comporta un rischio di strangolamento Al fine di evitarlo osservate le avvertenze sull uso del bracciale e Non eff
Download Pdf Manuals
Related Search
Related Contents
MANUEL D`INSTALLATION installation et ARMSTRONG® NETTOYANT CONCENTRE POUR PLANCHERS iTextiles 2.0 Instructor Manual Progress Lighting P5511-31 Instructions / Assembly SCENA 1000 ECLIPSE Auto / Service Bulletin / S2000 / a00-049 pdf MANUAL DE USUARIO - DAVI Y CIA, S.L. Copyright © All rights reserved.