Home

取扱説明書 - 株式会社エーエスシー

image

Contents

1. OBC UD TIL SAFE USE OF EQUIPMENT N WARNING Prohibit Installation on Rainy Day To reduce a risk of electric shock do not expose inside of this unit rain or moisture Installation on a rainy day may also cause condensation inside of Acrylic Window Installation Installation shall be done by qualified installer only and should conform to all local codes Ensuring strength of supporting Dome Housing Unit The unit must be properly and securely mounted to supporting structure capable of sustaining the weight of the unit Use four 4 M6 or 1 4 Stainless Screw Anchor on Concrete Use four 4 M6 or 1 4 Stainless Screw on
2. E H VCTF 1 25mm2 2mms ACG4V 24VAC Power Supply AC24V PSE 25W 1 1A A N CAUTION for U S A and Canada CAUTION for other countries Use 24VAC class 2 power supply which is UL Use 24VAC Power Supply isolated from 100 to Listed in the U S A or CSA certification in 240VAC which meets requirements for SELV Canada Safety Extra Low Voltage and complies with Limited Power Source according to IEC 60950 Note Total power consumption for Heater amp Blower Camera need to be added Example Camera Power 15W Blower 0 5W Heater 25W Total 40 5W Required Power 50VA Or you can prepare two separate 24VAC power source for camera and Heater amp Blower AC24V Wire Gauge EG Total vA 8 24VAC Wiring Distances consumed 22 20 18 16 14
3. SaN i ha AC100V 20W AC24V DC 12V PSE AC24V DC1SGV 25W 50C 40C
4. AC100V H VCTF 1 25mm x ene H VCTF 2mm xem VVF 32mm ml 47mm p omm2 O O 35C 27C CHIE 4 4C 16C AC100V 5W F AC100V 1A acioov AC100V 20W _ 125V 5x20mm 2A ram gt AN
5. DC182V DC12V 2 5W 0 5 W It is already wired and running test was done at our factory before shipment Just supply enough 12VDC power to input connector by paying attention to Polarity Red is 12VDC Blower and Heater run automatically by thermostat Power Consumption of Heater is 25W and Blower is 0 5W A N DC12V AN CAUTION RED is 12VDC Be careful of Polarity a Terminal No DC12V an Heater 12VDC No Polarity WHITE DC12V ee Heater 12VDC No Polarity WHITE DC12V Power Input 12VDC RED TE BHA DC12V Power Input 12VDC BLACK DC12V 12VDC BLUE DC12V Blower 12VDC RED 11 AC24V DC12V A PS 4 1 2 Optional 24VAC 12VDC Converter A PS2412 for Camera AC24V DC12V
6. Product Instructions for Outdoor Housing A OH15 N Please read this instruction manual carefully to ensure that you use the Product correctly and safely Read Important Safety Instructions Keep this instruction manual 1 2 3 4 5 6 7 8
7. 2 5A AC84V ACG4V LED Connect 24VAC Output to 24AC Input of this unit You can diagnose 24VAC Input and 12VDC Output by LED lamp Input Voltage 24VAC 10 Excessive voltage over 10 may damage this unit Output 12VDC Max 2 5amp A PS2412 a GND 24VAC IN 12VDC OUT No Polarity 12 Installation of Camera 31 0mm 275mm 95mm 1 00mm AC Note Camera bracket may vary from camera to camera See appendix instruction if any Basically it accepts 310mm 12 2 length without Blower amp Heater 275mm 10 8 length with Blower amp Heater x width 95mm 3 74 x height 100mm 3 9 As regards height it becomes narrower from the middle of it 310mm 12 2 275mm 10 8
8. 9 10 11 12 13 IMPORTANT SAFETY INSTRUCTIONS 1 2 3 4 5 6 7 8 9 10 11 12 13 JN WARNING Read these instructions Keep these instructions Heed all warnings Follow all instructions Do not use this apparatus near water Clean only with dry cloth Do not block any ventilating openings Install in accordance with the manufacturer s instructions Do not install near any heat sources such as radiators heat registers stoves or other apparatus including amplifiers that produce heat Do not defeat the safety purpose of the polarized or grounding type plug A polarized plug had two blades with one wider and the other A grounding type plug has two blades and a third grounding prong The wide
9. A CA15 Use optional A CA15 ceiling adaptor RC EADH tess LC Before installation please make sure maximum pan range A CA15 Maximum tilt down by optional A CA15 A SB20 1 500MM 20mm How to install wall bracket in pole by using optional A SB20 1500MM Stainless belt i Pole Mount 60mm You can use 20mm 0 787 width Stainless Belt Stainless Belt is not provided sem 1 Pull in Stainless belt through the slot Pay attention to the direction of cover and slot Wind up Stainless belt by the adequate torque You can wind it up by moving cover right and left Pay attention to the adequate torque Not too tight and Not too loose Too much torque may damage Stainless belt and thus breakes it How to cut Stainless
10. 95mm 3 74 3 9 13 LIMITED WARRANTY IN U S A ASC USA INC warrants that products sold hereunder shall be free from defects in materials or workmanship for a period ONE 1 YEAR from the date of purchase by the original end user customer the Warranty Period ASC USA INC makes no other warranty of any kind with respect to this products whether expressed or implied including without limitation the implied warranty of fitness for a particular purpose In the event of a breach of the above warranty ASC USA INC shall its option repair or replace said products or refund the purchase price paid therefor This is the exclusive remedy and ASC USA INC s sole obligation with respect to the above warranty In no event shall ASC USA INC be liable for any incidental or consequential damages as defined in section 2 275 of the Uniform Commercial Code for a breach of this warranty ASC USA INC shall repair or replace defective products upon shipment of products prepaid to ASC USA INC 5975 Shiloh Road Suite 103 Alpharetta GA 30005 Repairs made by necessary by reason of accident misuse or normal wear shall be charged at ASC USA INC s standard rate This warranty gives you specific legal rights and you may also have other rights which vary from state to state SERVICE If the product need repair service the customer should contact ASC USA INC for authorization top return and shipping instructions TEC
11. Wood Ceiling Prohibit changes or modifications of equipment You are cautioned that any changes or modifications not expressly approved in this instructions could void your authority to operate this equipment Caution for Power Supply Caution for U S A and Canada Use 24VAC or 12VDC Class 2 Power supply which is UL Listed in the U S A or CSA certified in Canada Caution for Other Countries Use 24VAC or 12VDC Power supply isolated from 100 to 240VAC which meets requirements for SELV Safety Extra Low Voltage and complies with Limited Power Source according to IEC 60950 Basic Operating Environmental Condition We warrant the products installed under normal outdoor 20 C 40 C 4 F 104 F We are unable to warrant the products which are installed indoor and exposed to constant high temperature over 40 C 104 F and over 90 humidity Operating temperature and humidity of camera varies from camera to camera You are requested to confirm camera specification with camera manufacturer and housing specification with us in advance Cleaning Acrylic Window You may have difficulty getting a clear picture due to raindrop when it is raining Acrylic Window may get dirt on it which is subject to environmental condition thus it deteriorates picture quality You are required to clean Acrylic Window periodically Waste Electrical and Electronic Equipment Directive amp Recycling Do not dispose it as an ordinary household
12. belt Press Stainless belt vertically by pliers After you cut Stainless belt Cut the center you pressed gt Bend the end of Stainless belt so that it can be within cover Close cover AC100V 100VAC Power Supply in Japan O O 1 25SQ A
13. blade or the third prong are provided for your safety If the provided plug does not fit into your outlet consult an electrician for replacement of the obsolete outlet Protect the power cord from being walked on or pinched particularly at plugs convenience receptacle and the point where they exit from apparatus Only use attachments accessories specified by the manufacturer Use only with the bracket specified by the manufacturer or solid with the apparatus Unplug this apparatus during lightning storms or when unused for long period of time Wi L M6 1 4 4
14. 12 10 5 5 250 400 600 960 5 10 120 180 300 480 800 1300 2 me right diagram are ihe recommended maximum 5 WP Vee aaa eat 1 Sos ao distances for 24VAC with a 10 voltage drop 10 30 65 90 130 225 350 525 830 is generally the maximum allowable voltage drop for 40 44 70 112 179 285 452 720 8 AC powered devices 50 35 56 90 143 228 362 576 2 60 29 47 75 119 480 70 25 40 64 102 163 258 411 oO 80 21 34 55 85 140 215 340 24VAC IN 24VAC OUT for camera use only 24VAC25W 12VDC Blower Heater fe Heater 35C 827C Blower Thermostat 35 C ON 27 C OFF 95 F ON 80 F OFF 4 4C 16C Heater Thermostat 4 4 C ON 16 C OFF 40 F ON 60 F OFF N CAUTION Keep cables away from Heater Blue Color to prevent damage of it due to heat Usually heater will be installed in front of window 10 DC12V 12VDC Power Supply
15. HNICAL SUPPORT If technical support is needed please contact ASC USA INC 5975 Shiloh Road Suite 103 Alpharetta GA 30005 Tel 770 888 4674 1 888 988 4674 Fax 770 888 4675 URL http Awww kk asc com ASC Corporation 3 16 9 Toranomon Minato ku Tokyo 105 0001 Japan Tel 81 3 5473 7627 Fax 81 3 5473 7628 14 Service and Technical Support Manufacture ASC T 105 0001 3 16 9 Tel O03 5473 7627 Fax 03 5473 7628 URL http www kk asc com ASC Corporation 3 16 9 Toranomon Minato ku Tokyo 105 0001 Japan Tel 81 3 5473 7627 Fax 81 3 5473 7628 ASC USA INC 5975 Shiloh Road Suite 103 Alpharetta GA 30005 Tel 770 888 4674 1 888 988 4674 Fax 770 888 4675
16. waste Follow local code for recycling A BK1 2 A CA 15 Installation of Wall Bracket A BK12 and Optional Ceiling Adapter A CA15 M6 1 4 4 1 4 Use four M6 or 1 4 stainless screws Not provided to install wall bracket Install Housing by using 1 4 screws x 2 provided on to wall bracket The unit must be properly and securely mounted to a supporting structure capable of sustaining the weight of unit E Wall Mount 4 M6 1 4 Use four 4 x M6 or 1 4 stainless screw and stainless anchor on concrete 7732 Installation of Sunshield 6 3 X3 8 Use 6 32 x 3 8 screws x 2 provided Km Ceiling Mount A CA15 4 M6 1 4 Use four 4 x M6 or 1 4 stainless screw

Download Pdf Manuals

image

Related Search

Related Contents

Operating Instructions - POINTRAC 31 - 8/16 mA/HART - four-wire  F Note  Reading Horizons - Backbone Communications  Transcend JetRam 512MB DDR2-667 CL5  NEW MEXICO - CenturyLink    T24-ACM - Hazardouslocation.com  Sharp XL-35H User's Manual  PORTEIRO ELETRÔNICO PORT-PHONE  Whitecap Pavilion & Associated Lands External User Guide  