1. If the Product is fuming or emitting odors immediately turn off the breakers on the unit and isolate from the main power supply Repair should be left to the care of your SEIKO agent or dealer If left uncorrected the situation will create the potential for electric shock or fire Tampering or unauthorized repair or modification of components may
2. Check the following items in case of troubles Phenomenon Cause Countermeasure Right after installation works Resumed from power failure Initialize the system Alarm lamp blinks Secondary Clocks stop in case of overload Overload Short circuit on output line Over connection of secondary clocks After fixing the cause push RESTART key 0 5sec secondary clock and 30sec secondary clock are not synchronized Wrong operation of time synchronization Operate correctly Tripping of DC NFB Overload Short circuit on output line Over connection of secondary clocks After fixing the cause turn on the NFB and push RESTART key Tripping of DC NFB Defective power supply Replace the power supply unit If the system does not work properly even after the above treatment consult the dealer where the system has been purchased 22 5320 4 E EXTERNAL VIEW Fy Panel Screws ka Terminal Blocks SE ocena D q ma Ta TT NN 3 ABA Int ABRA Inlets Back amp Bottom 100 30 23 5320 4 Mitte 0 5
3. When the power is turned on or resumed after power failure or RESTART is pushed it becomes IRE STAR this display In case of RESTART operation it will display the data right before the restart button is pressed The following screen is displayed ADJ 0 5CLK TO UT PUSH ANY KEY 0 5 0 5sec secondary clock stop Manual adjustment 3 0 ARIE 30sec secondary clock stop 0 5 UT Synchronize the position of the hour minute and second hands of 0 5sec secondary clock before starting UT Please set the time of UT as considering the operation period to adjust the hand position of all secondary clocks r Pe Please set the second hand only for 3
4. The following pictorial symbol indicates what you must not do The following pictorial symbol indicates what you must do Q General prohibition Prohibition of disassembly General need to do thing Wiring Earth terminal 2 5320 4 Contents Page E SAFETY PRECAUTIONS 4 B INSTALLATION amp WIRING UI 5 _ 1 O INSTALLING THE MASTER CLOCK 5_ _ 2 WIRING TO POWER SUPPLY AND SECONDARY CLOCKS 6 E HANDLING METHOD UI 7 1 INSPECTION BEFORE TURNING THE POWER SWITCH ON 7 _ 2 STARTING OPERATION 8 2 1 Operation Panel ne EEE REED ERED 8 _ 2 2 Operation Switches 8 2 3 o Operation RO RD 9 3 NORMAL OPERATION aaao ta _ SATUTI Z LT ORRY Switch the display of UT and LT 14 3 2 0 30 0 SEC ADJUSTMENT 30SEC ADJUSTMENT 14 3 3 LT MANUAL LT ADJUSTMENT 16 3 4 OPERATION OF DIMMER UI 17 4 ALARM DISPLAY 18 4 1 RESUMED FROM POWER FAILURE aaa 18 4 2
5. 0 5sec secondary clock running 30sec secondary clock stop Please push ENTER when the input of LT is correct LT starts Go to the next step Cle DEM To re enter the input move the cursor to by lt key to get the former screen 11 5320 4 The following screen is displayed INPUT 30CLK HAND B 00 00 gt 0 5 0 5sec secondary clock running 3 0 30sec secondary clock stop Manual adjustment 3 0 Synchronize the hands of all 30sec secondary clocks to the same position 3 0 Input the time same as the position of the hand of P 30sec secondary clocks lt gt Move Input frame blinking part by lt key or gt key Change the value by key or key 01 12 for Hour 00 59 for Minute
6. Each output line will be the following status 0 5 3 0 soo of IF lt lt EE 0 5sec secondary clock 30sec secondary clock Stop Digital signal output Stop Logger signal output Stop Alarm signal output Stop IRESTART After fixing the cause of trouble push RESTART key to initialize the system 19 5320 4 4 3 4 3 ABNORMAL POWER SUPPLY Benji Re s When abnormal condition lower voltage is detected on CA CE D C the AC DC power supply ca the following status is displayed AC For AC line WARNING UT 01707729 AC POWER gt 11 08 32 DC For DC line WARNING UT 01707729 DC POWER 11 08 32 WR RS FARR 1 Display of abnormal status and the current time is
7. alternately displayed at interval of one second MMR ASU Sh 1 The ALARM lamp blinks every second as well Each output line will be the following status 1 0 5 3 0 I a B BACON 0 5sec secondary clock 30sec secondary clock Normal Digital signal output Normal Logger signal output Normal Alarm signal output Active ON ENTER After fixing the cause of trouble pushENTER key to recover the system 20 5320 4 i 100mA 150mA R r D DC24V 5V 5 CONNECTION OF ALARM AND LOGGER Alarm signal and logger signal are output via circuit of Transistor open collector
8. 6 5 1 2 0mA 1 0 CH v D o EAH IDAR 30 150mA COM 24V DC24 5V 30 E HANDLING METHOD INSPECTION BEFORE TURNING THE POWER SWITCH ON Check on loosened inner parts printed circuit boards screws and so on Check on the adhesion of wire chips generated when working on installation 8 Check on polarity of wires connected to the secondary clocks and power supply The master clock is equipped with an over current limiter and its output signals are generated from solid state switches Insulate the field wiring with utmost care Also make sure not to overload the master clock Current capacity of each secondary clock is as follows 5 Current Type Signal co
9. SUSPENSION OF OUTPUT LINE 19 AS ABNORMAL POWER SUPPLY OO 20 _ 5 CONNECTION OF ALARM AND LOGGER _ 21 MAINTENANCE 22 BER O OOO EXTERNAL VIEW 00 23 OO SPECIFICATIONS UI 24 SR PORAFTER SALESERVICEPLEASE CONTACT 26 3 5320 4 E SAFETY PRECAUTIONS The following are the instructions you must observe not only for your own safety but also for the protection of others and the property Action to take against abnormal Situation Prohibition of unauthorized disassembly repair or modification Prohibition of allowing foreign objects in Power supply Earth terminal A CAUTION
10. 20 1 1 20 are used to adjust LT LT adjustment is effective only on the display of LT An example to advance 15 minutes is shown below Change the display to LT by LT 01707729 15 LT 2 0 UT 10 LT 19 tT 1 5 UT 10 11 LT 19 11 19 11 At the display on LT push 20 After the above operation push 1 five times ENTER 00 15 The display of PUSH and ENTER is alternately displayed at cycle of one second 0 LT 3 He Se X cf Fe lt 3 0 UT LT ve ILT W PushE NT E Rkey 30 sec secondary clocks will automatically catch up to the time of LT At the operation of if no input is made for 30 seconds or UT LTI is pushed T
11. H H 3 0 RS 2 3 2 as EB AE ay ER Es ay St H 0 2 5 lt 4 0 10 5 5 1 0 120mA 6 5 7 8 0mA Bul T 2 RS 422 1 NMEA0183 5 1 1 5 0mA 2 4V COMMON 3 0 3 0 2 1 1 0 0mA 2 4V COMMON 2 RS 232C 1 0 3
12. 150mA Max output capacity AB C Set and Set A B and C 0 5 30 0 5sec leap secondary 30sec leap secondary clocks clocks 6 5320 4 1 D CA eae Fat Ad Ay LAH PRE ARE ORIRE LUBAO HA lt 7 imi E ays vit dk Ra my ay 2 ou 30 DC24V 12mA 3 ou 0 5 DC24V 12mA N SS F 7 Tp 3 at Tu Dll 2 7 8 0mA
13. 7 llumination llumination Illumination BRIGHT The display will return to the normal display unless DIMMER key is not pushed within five seconds again It becomes the following display normal display LT 01 07 29 19 11 35 Illumination remains latest setting 5320 4 4 4 1 4 ALARM DISPLAY When a trouble on the system or the connected line is LED detected the ALARM lamp LED blinks the alarm ON signal is output and the status of phenomenon is displayed on the LCD simultaneously 4 1 RESUMED FROM POWER FAILURE When the power is resumed from failure it becomes the following display SHUT OFF 1 The ALARM lamp blinks every second The output line will be the following status
14. SET 01 07 29 LT me O3 0 5 3 0 LT lt gt CAR OAC ME IH H UT 13 00 0 0 Cs A 1 w H TLT AAR gt 10 0 5sec secondary clock running 30sec secondary clock stop Set LT ship time Move Input frame blinking part by lt key or gt key Change the value by key or key Set only Hour and Minute Year Month and Day are updated automatically The range of setting should be 13 00 13 00 against UT Please move the cursor to gt by gt key after input of the LT The display becomes as follows 01707729 PUSH 19 03 30 ENT 0 5 3 0 LT ENTER
15. Sample of connection 21 R f D Output Voltage less than 100mA ALARM less than 150mA LOGGER Relay Relay contact Arc extinguishing diode DC24V 5V 5320 4 mT OR H Ke RESTART 0 5 3 0 om DC U15 OUT PU U9 oH NF B ES TART AC U11 E MAINTENANCE
16. Panel mounting type 4 Fix the clock in place with bolts after processing the panel surface as shown in FIG 2 Fig 2 337 4 M6 5 5320 4 2 2 WIRING TO POWER SUPPLY AND SECONDARY CLOCKS Before installation synchronize all secondary clocks 1 2 0 0 Ex 12hr 0min 0sec Selection of service inlet The master clock is provided with two service inlets on the back and bottom The bottom inlet is blocked with a blank panel When using the bottom inlet relocate the blank panel to the back inlet Wiring 2 Loosen the panel screws and open the panel Connect wires to the term
17. 00 or 30 for Era aS ae 01 12 00 5 9 Second Please move the cursor to gt by gt key after the b twa gt gt gt input of the time of the hands position The display becomes as follows PUSH 12 00 00 ENT 0 5 0 5sec secondary clock running PS OPFER fE 30sec secondary clock stop Please push ENTER when the input of the time of the hands position is correct ENTER 30sec secondary clock starts to move Go to the LT 3 0 RS 2 To re enter the input move the cursor to by lt key to get the former screen 12 5320 4 During the adjustment the display becomes as follows LT 01707729 NOW 19 05 05 ADJ 0 5se
18. will be adjusted until clocks reach to UT and UT BEOILT HENEN e LT respectively It will take maximum 30 seconds to 3 0 complete the adjustment vets fee eae gt Ss Aid When the adjustment is completed it becomes the HET Pre aT following abies P LT 01 07 29 19 09 30 TO 5 0 5sec secondary clock running 3 0 30sec secondary clock running This 0 sec adjustment can be done on either display COOMBE TUT LT ai se Beate of UT or LT The result of adjustment reflects to the other 3 3 LTIj LT WT Slate LT ADJ Jo 2 0 1 1 20 4 LT LT 1 5 D LT L T 3 3 LT ADJUSTMENT Four keys
19. 0 0 5 3 0 0 5 AC85 250V 47 63Hz 35W 24V 10 1 4A 1 ERRIZ 24 5320 4 E SPECIFICATIONS Accuracy daily rate Temperature range for the rated accuracy Operating temperature range I O specification 0 5 second secondary clock output 30 second secondary clock output Digital signal output Logger signal output Alarm signal output option RS 232C signal output The way of time adjusting When power supply is turned on At normal operation AC power supply Range of input voltage Range of frequency Power consumption DC power supply Range of voltage Current consumption within 0 2 second day 5 C 40 C 10 C 55 C Two wired system Only clockwise 10 secondary clocks can be connected 120mA or less Three wired system Clockwise Counterclockwise 65 secondary clocks can be connected 780mA or less Two balanced wired system RS 422 One port Based on NMEA0183 Five wired system One port 150mA or less in total 24V COMMON 30 second polarized signal output 30 second polarized signal output Sign
20. 0 5 3 0 ie AEk ON 0 5sec secondary clock 30sec secondary clock Stop Digital signal output Stop Logger signal output Stop Alarm signal output x Active ON Push any key and operate from the initial operation 18 5320 4 4 2 4 2 SUSPENSION OF OUTPUT LINE When abnormal condition is detected on the output AC DC H line of secondary clocks or logger output or input line of AC DC power supply the following status is displayed ACCIDENT UT 01707729 OUTPUT STOP STP 11 08 32 WR RS FARR 1 Display of abnormal status and the current time is alternately displayed at interval of one second ERRITO 1 The ALARM lamp blinks every second as well
21. 0sec IPEA ae pe a o secondary clock with second hand Push any key when the setting of hand position nished Go to the next step 9 1 5320 4 The following screen is displayed SET WYJ 01701 UT 00 00 00 O gt 0 5 0 5sec secondary clock stop gt Manual adjustment 3 0 ARIE 30sec secondary clock stop UT Set UT universal time L CRE Move Input frame blinking part by lt key or gt key Change the value by key or key 00 99 01 1 2 00 99 for Year 01 12 for Month 01 31 for 01 31 00 2 3 Day 00 23 for Hour 00 59 for Minute 00 5 9 00 0 59 5 for Second decimal should be 0 or 5 el OO Ooo Se However any input which does not exist 0 5 example 30 February is ignored and the leap year is automati
22. SEIKO fi HE FA esd Be BT MARINE MASTER CLOCK QC 6M4 QC 6M4 Thank you so much for purchasing Seiko Marine Master Clock QC 6M4 Before putting your QC 6M4 to use please be sure to read this manual carefully as it has been prepared to assist in the installation operation and maintenance of your QC 6M4 You are recommended to keep this manual for future reference SEIKO TIME SYSTEMS INC 5320 4 v e e eR Attention 1 1 This manual is the property of SEIKO and may not without the express written consent of SEIKO be copied or reproduced in any form in whole or in part or used for any purpose other than that for which it is supplied 2 2 The content of this m
23. adversely affect safety or performance of this equipment Failure to follow this instruction may lead to a risk of electric shock or fire Repair should be left to the care of your SEIKO agent or dealer Never put any pin wire metal piece or any other foreign object into a hole or gap on purpose or otherwise If a foreign object is allowed into a hole or gap by mistake disconnect the main switch and call your SEIKO agent or dealer for inspection and servicing If left uncorrected this hazard creates the potential for electric shock or fire Never operate the product on any power supply other than specified If left uncorrected the situation will create the potential for electric shock or fire Earth terminal should be grounded to protect the product from inductive disturbance E INSTALLATION amp WIRING 1 1 INSTALLING THE MASTER CLOCK D Wall mounting type A aN H C7 gt gt 4 Fix the master clock to a wall surface with four E installation holes 6 mm Installation dimensions are indicated in Fig 1 6mm dia bolts are suitable Fia 1 365 9 4 65 E ae emoa d fa aiia Wy oe Q
24. al output during time adjusting Signal output during counterclockwise Two wired system One port 100mA or less 24V COMMON Alarm Two unbalanced wired system RS 232C One port The content is the same as the digital signal output Key input and Digital display on the front panel Reset to 00 sec by 0 second adjust button 30 second adjustment After the above operation hands of 0 5 sec secondary clock will follow by stop or fast forwarding 30 sec secondary clock will follow promptly AC 85 250V 47 63Hz 35W DC 24V 10 1 4 A Power supply automatically switched from AC to DC system without interruption in case of AC power failure 25 5320 4 E FOR AFTER SALE SERVICE PLEASE CONTACT 231 0047 2 5 13 Tel 045 243 8090 Fax 045 261 6111 UP Co LTD 5 13 2 Chome Hagoromo Cho Naka ku Yokohama 231 0047 Japan Tel 81 45 243 8090 Fax 81 45 261 6111 UTSUKI KEIKI Co LTD 3530 Kamiyabe Cho Totsuka ku Yokohama Japan Tel 81 45 813 8481 Fax 81 45 813 8491 26 GEORG HECHELMANN NACHF GMBH Randstrasse 30 22525 Hamburg Germany Tel 49 40 5477760 Fax 49 40 54777666 Telex 2163852 NAVID KELVIN HUGHES NETHERLANDS LTD Klompenmarkerstraat 64 3194 DC Hoogvlit Rotterdam The Net
25. anual may be subject to change without notice lt 3 3 This manual has been prepared to give complete information necessary for the operation use handling and maintenance of the products For the purpose of our constant technical manual improvement program your questions advice suggestions and comments on the descriptions illustrations procedures or any matter concerning this manual are highly appreciated 4 4 SEIKO shall not be liable for any failures of the products or direct or indirect damages resulting from such failures if such failures are caused due to abuse misuse failure to observe instructions given in the manual and neglect of other reasonable care an
26. c secondary clock running et Pik PaO MM SHA SES zul 0 Si Pat E 30sec secondary clock adjustment 3 0 When the time adjust is completed the display becomes as follows Normal display LT 01 07 29 19 08 32 0 5 0 5sec secondary clock running 30sec secondary clock running 3 0 ei 13 5320 4 3 3 1 TUT Z TLT ORRDS UT LT UT LT UT 01 07 29 10 08 32 3 2 0O 30 30 0 O0 SEC ADJ 3 NORMAL OPERATION 3 1 Switch the display of UT and LT The time display shows UT or LT du
27. cally adjusted 2 3 0 Please move the cursor to by gt key after input of the UT The display becomes as follows 01707729 PUSH 10 03 00 O ISINE UT gt 0 5 0 5sec secondary clock stop 3 0 30sec secondary clock stop Please push ENTER key when the current time UT reaches to the input time of UT ENTER UT starts Go to the next step To re enter the input move the cursor to by lt key to get the former screen 10 5320 4 The following screen is displayed
28. cks will be adjusted as synchronizing with 0 5 sec secondary clocks 5320 4 IT ASSET ECRES It takes maximum five minutes to complete the adjustment When the adjustment is completed it becomes the following display LT 01 07 29 19 14 00 0 5 0 5sec secondary clock running 3 0 30sec secondary Clock runnindg CORRECTION WHEN RUNNING FAST LT 01707729 19 09 29 0 5 0 5sec secondary clock runnindg 3 0 30sec secondary clock running Under this status when 0 SEC ADJ is pushed it becomes the following display LT 01 07 29 N OW 19 09 00 ADJ 0 SEC AD 0 5 0 5sec secondary clock adjustment fast moving 3 0 30sec secondary clock adjustment fast moving 0 5 3 0 0 5 sec secondary clocks and 30sec secondary clocks
29. d servicing due to be done by the owner irrespective of such instructions and failure due to deliberate actions or gross negligence or accident or caused by changes modifications or alterations made without prior written consent of SEIKO or by any person other than authorized by SEIKO SYMBOLS AND THEIR MEANINGS The symbols and terms used in this manual are explained below DANGER is used to indicate the presence of a hazard which will cause severe personal injury death or substantial property damage if the instructions under this heading are ignored Any accident caused under this category implies a situation to which you must respond immediately with corrective actions CAUTION is used to indicate the presence of a potential for personal injuries or property damage if the instructions under this heading are ignored
30. h used for initialization or at RESTART To turn back one To decrease the To increase the To forward input To enter the input input frame displayed displayed frame or displaying numerals and the or displaying page numerals numerals page to next page 8 5320 4 2 3 2 3 Operation AC U11 DC U15 Please turn all three breakers of AC U11 OUTPUT U9 3 DC U15 and OUTPUT U9 on ON The following initial screen is displayed m 0 5 0 5sec secondary clock stop 3 0 30sec secondary clock stop Push any key to go to the next step
31. herlands Tel 31 10 4167622 Fax 31 10 4167218 Telex 26545 OBMAR NL KELVIN HUGHES LTD New North Road Hainault Ilford Essex 1G6 2UR UK Tel 20 8500 1020 Fax 20 8559 8441 ZENITEL MARINE P O BOX 1068 Bromsveien 17 3194 Horten Norway Tel 47 3303 1660 Fax 47 3303 1661 THONG SIA WATCH CO LTD 21 F Stelux House 698 Prince Edward East San Po Kong Kowloon Hong Kong Tel 852 2736 0235 Fax 852 2730 5350 THONG SIA CO S PTE LTD 04 00 Thong Sia Bldg 30 Bideford Rd Singapore 0922 Singapore Cable THONGWATCH Telex SELTIME RS 24091 Tel 65 6737 6122 6lines Fax 65 6734 0284 5320 4 SEIKO TIME SYSTEMS INC URL _http Awww seiko sts co jp 5320 4
32. his operation is to be canceled and the display will return to the normal mode 5320 4 3 4 DIMMER HG D I MMER 1 am DIM 0 AC DC 5 ID IMMER AC ON 3 4 OPERATION OF DIMMER Adjustment of the brightness of LCD can be done by DIMMER key The status of the input line of power supply can be confirmed as well When the DIMMER key is pushed once it becomes the following displays DC ON Each status of the illumination the AC power supply and the DC power supply is displayed from the left end The display changes as follows when the DIMMER key is pushed within five seconds I 5
33. inal blocks located on the lower right side of the clock with clamping tools Be sure to use the clamp terminals provided for Fig 3 connecting wires Correctly connect the wires according to Fig 3 Caution Earth terminal should be grounded as in fig 3 to protect the master clock from inductive interference Printed Circuit Board Les tea i i 0 5 3 120mA 10 30 3 780mA 65 0 5 sec secondary clocks 3 Maximum capacity 120mA 10pcs Earth terminal 30 sec secondary clocks 3 Maximum capacity 78OmA 65pcs TB1 a ain Bi Re ie E uondO uuJelV fl zzy S MELL 0z8z SH A ad 6uluuni Ae Buunp dyno rav 6unsnlpe puey 5uunp ndinO UOWWOD ApZ 1ndinO IeuBIS Ie1I5I CHES indjno jeubis ieys CHEW KAS 3 f abv REV Ld ae ne re L RS 49 e rs L sas AL a HH polarized Logger
34. nsumption 2 hands 30 sec secondary polarized DC24V 12mA clock signal 3 hands 0 5 sec secondary polarized DC24V 12mA clock signal Note Double faced type should be counted as two times of the above table The maximum output capacity for 2 hands secondary clock is 780mA Max 65pcs The maximum output capacity for 3 hands secondary clock is 120mA Max 10pcs The maximum output capacity of the logger signal is as specified below Never load the master clock circuit with the logger in excess of the specified capacity If the logger input circuit uses a relay provide a spark killer Signal 30 sec polarized pulse During rev turning pulse During hand setting pulse COM 24V Max output capacity 150mA in all Note The 30 sec polarized signals and the logger signals may fluctuate approx within DC24 5V depending on the number of secondary clocks 7 5320 4 2 2 STARTING OPERATION 2 1 2 1 Operation Panel ALARM os O DIGITAL DISPLAY PART gt RESTART SET UT LT SECONDARY HANDS ABOUT DIGITAL DISPLAY C gt gt BLINKING AB C ABC CD ABC gt LIGHTING ABC 2 2 2 2 Operation Switches RESTART lt Switc
35. ring normal operation UT LTI The display can be switched whenever S pushed LT O1Y07 729 19 08 32 VAG 3 2 0 SEC ADJUSTMENT 30SEC ADJUSTMENT Push 0 SEC ADJ button at the tone of exact 0 second to correct accumulated error within 30 seconds OPERATION OF 0 SEC ADJUSTMENT ADJUSTMENT WHEN THE CLOCK LOSES 33 0 5sec secondary clock running 30sec secondary clock running LT 01 07 29 19 08 0 5 3 0 0 SEC AD Under this status when 0 SEC ADJ is pushed it becomes the following display LT 01707729 N OW 19 09 00 ADJ Het 0 5 3 0 Bulli 0 5 1 1 L UT 3 0 LT 0 5sec secondary clOock adjustment fast moving 30sec secondary clOck adjustment fast moving 0 5 sec secondary clocks will be adjusted to synchronize to UT at speed of 1 1 times faster than normal movement 30 sec secondary clo