イオナイザ取扱説明書
Contents
1. iT D202671 10 10022014 JF X200 2513 Instruction Manual for lonizer Thank you very much for your purchase of the JFX200 2513 optional ionizer Please read this manual and fully understand it before using the device If you have any question contact your local distributor Before using For note and safety refer to the instruction manual of JFX200 2513 main body Before using be sure to read Warning and Note of this manual and fully understand its contents It is recommended to check the effect of removing electricity in advance M e It is possible that enough effect cannot be achieved depending on your using environment or the media Wy DIN E At normal printing printing from operation panel side to Y bar waiting side After setting the media make the machine REMOTE status and print from RasterLink The function to remove electricity operates and
2. 4 1
3. 1610mm Y 0mm Y 1610mm Y RasterLink Y FRAT SOMNMHOES E 1
4. 2 E 3 E AAMKE Fh ih tebe E ION ALM COND COND 1 3 1 2 1 1 JA al me BA Vio SPA 0208
5. X200 2573 JFX200 2513 JFX200 2513 M Wz e E Y RasterLink m Y
6. probe it may cause an accident or failure of the machine AAIMAKT Alarm output function This ionizer has the function to output alarms E Alarm output part ct ION ALM COND Indicator light E Alarm function Item Alarm ALM lon level ION Condition COND Indicator light blinks three Indicator light blinks twice Indicator light blinks once Indication times about every second about every second about every second Internal circuit has been Due to blot on the electrode The installed environment broken probe and wear of it ion temperature humidity Status etc Abnormal discharge occurs production has decreased peripheral metals etc have Use this as a guide for time to laffected the performance to take care of the electrode probe remove electricity Removing electricity stops Removing electricity continues Removing electricity continues electricity Contact a distributor in your Take care of the electrode Check the environment and district or our office probe peripheral metals If the status cannot be improved replace the relevant electrode probe SPA 0208 Tungsten electrode probes for Countermeas ure Replacement part ionizer including 4 1 Before taking care of the electrode probe turn off the main power of the main body and be careful to perform the work Warning and Note High voltage is applied Prevent it from water oil flammable
7. solvent etc being poured Other wise breakdown occurs or it may cause an electric shock and failure of the machine Do not put metals your body your finger etc closer to it It may cause an electric shock and failure of the machine There is a danger that generated ozone may do something detrimental to you if the machine is used in the close place When you use the machine in the close place be sure to ventilate Do not use in a place where the temperature changes significantly or dew condensation occurs Before maintaining or taking care of it be sure to turn off the main power of the main body When taking care of it do not touch the electrode probe directly Should an abnormality is found contact a distributor in your district or our office Do not repair the machine by the customer It may cause an electric shock and failure of the machine Do not touch the electrode probe with a hard thing such as a tool It may cause an accident or failure of the machine Due to prolonged use dust ink adhere to the electrode probe and it becomes dirty If you keep using it as it is the machine cannot produce the performance to remove electricity enough and it may cause an accident or failure of the machine Be sure to take care of it Do not use this for any purpose other than eliminating static electricity Caution
8. it prints the media while removing electricity of it E At reverse printing printing from Y bar waiting side to operation panel side FUNCTION VIEW SET VIEW POS 1610mm move the Y bar Set the media setting FUNCTION VIEW G _ SET VIEW POS Omn move the Y bar FUNCTION VIEW SET VIEW POS 1610mm move the Y bar During that time the function to remove electricity operates and electricity of the media is removed Make the machine REMOTE status and print from RasterLink While the Y bar is moving fully be careful about your body or things not to hit it Daily care Check the electrode probe before the work and clean it if it is dirty You may get an electric shock Also you may get injured collaterally A e Before taking care of it be sure to turn off the main power switch of the main body Caution Do not touch the electrode probe directly You may get injured Be careful to work E Method for daily care 1 Remove the electrode probe from the ionizer By using the attached electrode probe replacement kit you can remove it easily 2 Wipe off the electrode probe and around it with a cotton swab immersed in alcohol Recommended ethyl alcohol isopropyl alcohol E When it is very dirty Use an ultrasonic bath Also you can use alcohol as washing liquid E Note After cleaning fully dry it and then attach it to the ionizer to use When washing liquid remains on the electrode