Home
USB-シリアル通信変換ユニット USB001Z 取扱説明書
Contents
1. a VAR sti n TOSHIBA E6581282 2 1 USB 1 2 USB 1 Ht E6581282 CB CD ROM Ch 1 L Web A Web E6581298 GX E6581299 OS W e b www inverter cojp
2. TOSHIBA E6581282 USB to Serial Conversion Unit Instruction Manual USB001Z Thank your for purchasing a USB to serial conversion unit USBO01Z an optional device for the TOSVERT series inverters This instruction manual contains important information to avoid endangering actual operators and other persons and damaging properties and to ensure the proper and safe product usage Please read this manual carefully along with the instruction manual for your inverter and the communication function manual When using the USB to serial conversion unit keep this manual handy for future maintenance and inspections Please confirm the latest applicable OS and information from your Toshiba distributor TOSHIBA E6581282 1 Safety precaution The items described in these instructions and on the inverter itself are very important so that you can use the inverter safely prevent injury to yourself and other people around you as well as to prevent damage to property in the area Thoroughly familiarize yourself with the symbols and indications shown below and then continue to read the manual Make sure that you observe all warnings given E Limit in purpose V Never use this unit with any device other than TOSVERT series inverter or it could cause an accident E General Operation Warning Never disassemble modify or repair Disas
3. Adobe Acrobat Reader 5 0 Aqgobe Acrobat Reader Web USB 3 3 USB 1 OF F 1 5 2 USB USB USB US B US B CD ROM
4. a HES NS BANE AIC DUT v ae R k BRE E HEBE OFF Y
5. TOSHIBA E6581282 Binh F AS 1 3 RS485 2wire type LOGIC USB Option Unit R an l Ziizi 4 VF AS 1 USB A USB USB1 1 2 0 GABOON 2m 900OCS CABOO1 1 1 2m 1m CABOO13 CABOO15 4 USBOO1Z e4 i Le z 8 RS485 2 PCMOO1Z VO13 PCSOO1Z VOO1 Windows XP SP3 Windows Vista SP1 SP2 Windows 7 32bit 64bit 2 GEEL INUDUAR S ICUSBR bk A 1O0OOm It X Se i 5 9m 7s O 6G MF 10 55Hz JIS C 60068 2 6 1 OS We b wwwjinverter cojp X2 Windows Microsoft Windows operating system
6. 3 US RS485 2wire type fl VF nmC3 S15 FS1 AS1 PS 1 RS485 2 7 LOG1C VF nC1 S9 S 1 1 A7 P7 RS485 2wire type LOG1C 4 U SB 1 USB USB PCMC 1A SS a A iS USB
7. Microsoft Windows Windows Vista Microsoft Corporation 3 5 1 1 2 3 1 2 3 4 USB 4
8. SB 1 1 2 0 CAB0013 Recommended Cable length 1m CAB0015 4 Specifications Model number USB001Z Model with either an RS485 2 wire type connector or a common serial connector Usable applications PCM001Z V013 or successor PCS001Z V001 or successor Windows XP SP3 Windows Vista SP1 SP2 Windows 7 32bit 64bit However the personal computer must have a USB port series A Indoor operation at an altitude of 1 000m or less and free from direct sunlight Use environments potentially corrosive or explosive gases steam dust particles dust dirt and machining fluids grinding liquid coolant included Ambient temperature 0 to 50 C Storage temperature 25 to 65 C Relative humidity 20 to 93 free from condensation and vapor 5 9m s 0 6G or less 10 to 55Hz Compliant with IEC 60068 2 6 Cooling method Self cooling 1 Please confirm the latest applicable OS from your Toshiba distributor 2 Windows is listed above as the abbreviation for a Microsoft Windows operating system Microsoft Windows and Windows Vista are registered trademarks or trademarks of the US Microsoft Corporation in the USA and other countries 3 No warranty as to the suitability of this product for any computer and any peripheral equipment is either made or implied 5 Warranty Any part of the unit that proves defective will be repaired free of charge under the following conditions 1 This product will be
9. TOSHIBA E6581282 USB USBOO1Z USB USBO O1Z U SB USB O SS We b www inverter cojp DRS TOSHIBA E6581282 pn gt 1
10. er is no longer lit Your personal computer can remain powered on 3 Connect an inverter unit connection cable optional between the communication connector of the USB001Z and that of the inverter At this time be careful not to apply force to the connectors Refer to the instruction manual of the inverter for connection to the connection port of the inverter RS 485 2 wire type side Connectable to such an RS485 2 wire type interface port as that of the VF nC3 15 FS1 AS1 or PS1 LOGIC side Connectable to such a common serial interface port as that of the VF nC1 S9 S11 A7 or P7 Connect the cable only to either RS485 or LOGIC 4 Turn on the power to the inverter and set communication parameters Before disconnecting the USB communication unit also perform above step 1 beforehand Avoid connecting the conversion unit to a USB hub or extended USB port e g PCMCIA card Or else the conversion unit may become unstable depending on the environment in which it is used N V Do not disconnect the USB cable during communication with the inverter Prohibited Otherwise damage of malfunction will result TOSHIBA E6581282 m Example of connection In the case of the VF AS1 3 RS485 2wire type LOGIC VF AS1 ate Option Unit 7 Inverter unit connection cable Optional USB cable A B connection type Model number Cable length Use a commercially available USB cable CAB0011 Compliant with U
11. k QQ V Even if this product is deactivated by the occurrence of an event such as an abnormality when power is supplied to the inverter do not bring any regions of your body into contact with the inverter Prohibited TOSHIBA E6581282 2 Accessories check The USB to serial conversion unit is composed of the items listed below Check for missing or damaged components RS485 2wire 1 USB to serial conversion unit ooo eeeeeee sete eeeeetteeeeeeteeeeeeeaaes 1 USB001Z 2 USB to serial Conversion Unit Instruction Manual 1 This manual E6581282 ra 3 6BEROMLLOU Se 1 Device driver Uninstaller i Instruction Manual Detailed version E E6581298 Japanese manual E6581299 English manual Please confirm the latest applicable OS and information from your Toshiba distributor Adobe Acrobat Reader version 5 0 or subsequent ones is needed in order to look the Instruction Manual Adobe Acrobat Reader can be downloaded from the web site of Adobe Systems Inc Note This unit does not include an inverter unit connection cable or a personal computer unit connection cable Purchase these cables separately Refer to section 3 3 Connecting and starting the USB001Z unit To connect the USB001Z unit to your computer follow these steps 1 Turn off the input power to the inverter and after waiting for at least 15 minutes make sure that the charge lamp on the invert
12. repaired free of charge if some trouble occurs under normal handling within one year of delivery and is caused obviously by a defect in design or workmanship 2 The warranty applies only to the delivered unit 3 For the following kinds of failure or damage the repair cost shall be borne by the customer even within the warranty period 1 Failure or damage caused by improper or incorrect use or handling or unauthorized repair or modification of the inverter 2 Failure or damage caused by the unit falling or an accident during transportation after the purchase 3 Failure or damage caused by fire salty water or wind corrosive gas earthquake storm or flood lightning abnormal voltage supply or other natural disasters 4 Damage due to the use of the USB serial communication conversion unit for non intended purposes 4 lf there are any warranty conditions otherwise provided for those conditions will govern
13. sembly This can result in electric shock fire and injury For repairs call your sales agency prohibited Don t place or insert any kind of object into the inverter electrical wire cuttings rods wires This S can result in electric shock or fire Prohibited Do not allow water or any other fluid to come in contact with this unit Do not wipe this unit with a wet cloth That may result in electric shock or fire If this unit begins to emit smoke or an unusual odor or unusual sounds immediately turn power off Q If the equipment is continued in operation in such a state the result will be fire Call your local sales Mandatory agency for repairs Transportation amp installation Warning S Y Don t place any inflammable objects nearby If a flame is emitted due to malfunction it will Prohibited result in a fire Don t install in any location where the unit could come into contact with water or other fluids This can result in electric shock or fire Q Must be used in the environmental conditions prescribed in the instruction manual Use under any other conditions will result in malfunction Provide your inverter or other equipment with safety devices to prevent a serious accident from resulting even if the unit malfunctions or fails to operate Usage without a safety device can result in an accident E Operations Warning terminals Contact during the power on status of the inverter can result in electric shoc