LAMp ソフ トダウンステー SDS- cs。ーN 取扱説明書 聯

image

Contents

1. O 1 O O DC 40C
2. SEE EVE See E a 03 3864 1 1 AN A S 9 00 17 30 SUGHTINE FAX 03 3863 6875 po i ISO 9001 JSAQ384 IS014001 JSAE597 E mail support sugatsune co jp 1809001 018 ee EUe eiaa 2 5 10 7101 0032 http www sugatsune co jp 2015 02 PRINTED IN JAPAN 0035 10 LAMP SOFT DOWN STAY SDS C301N INSTALLATION INSTRUCTION De Please read this instruction sheet carefully for proper installation and operation Incorrect installation and improper use of the product may damage the unit or cause injury This stay is designed for furniture or lightweight door and is equipped with a damping function Sugatsune guarantees the quality of this product as for all its parts It cannot however guarantee the final assembly as a whole This product was manufactured and delivered with our utmost care Should you however find any defect please contact your dealer immediately Sugatsune warrants that this product is free from defect for a period of one 1 ye
3. O O O ty z _ 1 a Em se 2 pe IS GE 20mm ae ee 0 100 200 300 400 500 600 700 800 900
4. 0 5 20mm mm No SDS C301N 3 5x4 3 5X2 m 2 x kg x 9 8 3 92 6 86 N m 40 70 kgf cm CERTE ERATA HTE NJ EA A B C LE A B C f ZS 8 8 Rls A B c A F i S m z B i 100 135 WRB I n 45 poe 12 97 132 lo d EEN TaS WEC all 2gose 19T 18 14 BU 254 KT WS 20mm
5. A pe ee gt TRI _ _ L PAE Z t al Ne LI N65 105 EE EE Ik 195L T 844 i t 90 90 90
6. Phone 81 3 3866 2260 Phone 44 118 9272 955 Phone 1 310 329 6373 Phone 86 21 3632 1858 F a x 81 3 3866 4447 F a x 44 118 9272 871 F a x 1 310 329 0819 F a x 86 21 3632 1868 E mail export sugatsune co jp E mail sales sugatsune co uk E mail sales sugatsune com E mail lamp sugatsune com cn Website www sugatsune intl com Website www sugatsune co uk Website www sugatsune com Website www sugatsune com cn 1S09001 Japan Offices and Sugatsune America and ISO14001 Chiba Production division and Logistics center certified
7. LAMP SDS C301N we g 1
8. ar from the date of delivery Sugatsune liability is limited to the replacement of this product by a similar one free of defect In no case does this extend to the replacement of the installation or the cabinet as a whole Please keep these instructions at hand for future use Sugatsune cannot be held liable for any damage or injury caused by improper use or one different than the one this product was designed for ZA CAUTIONS Any failure to observe the following precautions may result in personal injury or damage to the cabinet Make sure that installation position and specifications are followed Unsuitable installation position may damage the mechanism when in case two stays are used together Make sure that the arm of the stay is parallel with the side panel of the cabinet Please avoid forced opening beyond the opening angle and using excessive force while closing the door O This product is designed to operate at room temperatures between 0 C to 40 C 32F 104F This product has a spring at the elbow section Please be careful not to get your fingers caught in elbow section while you are handling the unit Performance of hardware will be affected by unique factors in each application Hardware must be tested in intended application to confirm the function It is necessary to periodically check the fixing screws for loosing Tighten the loosed screws as required Do not force the door to close faster It can cause damage to the pro
9. duct or hinge s a THE DIMENSION OF THE FLAP A SOFT DOWN STAY must be used taking the size of the flap into REICH consideration The graph indicates the usable range when us a ing one SDS stay When using two stays the width of flap can be twice as large if the height remains unchanged ag Note The graph shown to the left is in case of a general wood lt A ti am en flap of 20mm thick specific gravity approx 0 5 we TI y In case of lighter or heavier flap doors that do not fit within lt ee ee ee ee e the above specified range please contact your dealer FLAP THICKNESS 20mm FLAP WIDTH mm APPLICABLE TORQUE MOMENT Code No Suitable Screw on mounting plate Suitable Screw on arm fixing plate Check the torque moment of your door or lid by using the following formula SDS C301N 93 5x4 93 5x2 1 piece use 1 2 of Door Height m x Weight kg x9 8 3 92 6 86 N m 40 70 kgf cm A i Flap edge 2 pieces use 1 2 of Door Height m x Weight kg x 9 8 cae Ot DR nga 7 84 13 72 N m 80 140 kgf cm or piano hinge Flap a F T n D T 55 Ea PLATE POSITION FOR INSTALLATION ed Depending on the type of the hinges used the position of the mount IO Pail I ing plate a
10. nd arm fixing plate should be fixed as indicated below for concealed hinge In this case where LAMP hinge 230 26 19T is used the distance a5 5 Arm fixing plate 9 for A B C is measured from the flap edge me Side ty Z Coverage Hinge Type A B C When other types of hinges board ii Overlay Single 100 135 are used please contact Inset Knuckle Hinge 97 132 your dealer Mounting plate Concealed KN j af P D Hinge 108 148 1 inch 25 4mm POS O11 In cace of 20mm thickness door Li 165 10 5 ape z Cm sal R points upward vertically 1 points upward vertically i up a Door Door down HOW TO INSTALL 1 Install the mounting plate and arm fixing For right side board For left side board plate with the enclosed wood screws at the ADJUSTMENT MHR Turn the main body 90 degrees With tne flap fully opened adjust the Insert the key of the cam of arm tip into and insert the pin of the mounting plate SCIBW nitting the Stopper pin Sostna are key hole of the fixing plate The iain in the hole of the main body the arm of the stay is straight body must be placed at 90 degrees angle against the fixing plate Fix the main body with bind screw provided Flap x Arm fixing plate stopper pin Side board Side board g SUGATSUNE KOGYO CO LTD SUGATSUNE KOGYO UK LTD SUGATSUNE AMERICA INC SUGATSUNE SHANGHAI CO LTD