Home

取扱説明書

image

Contents

1.
2.
3.
4. UV
5. BE C 45
6. 2 ERROR 1 LU Me Ari ERR RE at eet at E E ETT 1 NN o 1 2i et NPA DA Oe E E E E E E A 1 GG 1 OO 1 1 3 EPF 3000 4 1 100ml 1 100ml
7. 10 11 1 BRO RRA 11 2 Lid abditus 8 ee N PTFE DE M ikone ABS Fig 8 A 6
8. SED PLUS Ele pette Filler EPF 3000 A D miam S Us Ed 2 8 10 2 3 N
9. 9 4 45u N 10 10 1 4 8 T sh LEVO PLUS
10. 10 5 7 LCD J Le J 1 H7 10 6 AN A A A N 11 T T 2A
11. 220g 8 LCD 8 ISO9001 13485 GLP 5 25 30ml 5 8 290 L x 520 D x 298 H 220g 6 LEVO PLUS Electric Pipette Filler EPF 3000 7
12. we ee ee Cat No Product 291020 EPF 3000 290008 Standard aspirating cone for EPF 3000 712912 RRA A 11 3 HY PCB 10 PCB 211 Li ion Battery Li ion Battery PCB B 9 E 10 E 11 11 17400032 EPF 3000
13. f M RM QU LE g 6 7 e Ne 12 H EPF 3000 1 100ml CERT cQ TIR c CONTENTS 2 Doo mmo M D zn A Q zh O ue UDEOSNS
14. 37 TEL 075 583 3 700 FAX 075 583 3705 E mail kyoto Ims co jp 7530 0044 2 5 20 TEL 06 6354 8755 FAX 06 6354 8788 E mail osaka Ims coJp 7811 2305 MURR AS 872876 1 TEL 092 626 2505 FAX 092 621 8878 E mail fukuoka Ims co jp 7901 2206 631 8 TEL 098 893 8226 FAX 098 893 8227 E mail Okonawa Ims coJp http www Ims co jp E L O LMS CO LTD Tanaka Bldg 3 6 7 Hongo Bunkyo Ku Tokyo 113 0033 Tel 813 5842 4171 FOX 613 3616 7075
15. Ea O 4 0 10 2 10 3 6 10 4
16. ntu VAN 1 2 3 Es tu ER a Y 5 UN d e
17. N 17000205 EPF 3000 12 o lt 13 1
18. LCD 9 9 1 7 9 2 7 9 3
19. Thank you very much for purchasing the HARMONY Electric Pipette Filler LEVO PLUS Your Electric Pipette Filler is CE Certified and designed with function reliability and safety in mind For safe operation please pay attention to the alert symbols throughout the manual 3 Package Contents ei 1 unit Power supply se 1 ea Lithium ion rechargeable battery ss 1 ea Unsteril membrane filter 0 45 um 1 ea Wall Holder LLL 1 ea Operations Manual 1 ea Quality Control certificate 0 LLL 1 ea 4 Features A full volume range of 1 100ml Levo Plus can be used with all plastic or glass pipets between 1 100ml Easy to one handed operation Lightweight ergonomic design allows longer fatigue free pipetting Lithium ion battery offers long runtime charge and no battery memory problems Self regulate the aspirate and dispense by circuit feedback Large LCD display provides visual confirmation of remaining battery charge and speed settings The aspirate and dispense speed controls are separate Button at the upper part of the handle allow you to set your aspiration and dispense speeds Eight speeds are available for aspirate and dispense liquid If the dispense button is pressed only up to a point where a check can be felt the dispensing function will be based on the force of gravity and the liquid will simply flow out Comply with ISO9001 13485 and GLP guidelines 5 Specifications Aspirating Speed 25
20. should there be overheating KS Operating the device Warning Do not operate the device before reading and fully understanding all instructions in this manual Observe the national regulations for handling these substances as well as the material safety data sheets and manufacturers application notes Wear personal protective equipment This device is not designed to be user serviceable Do not attempt to open or modify the device Should be device be opened by unauthorized personnel all warranties are void Should there be any abnormal smell or noise during operation switch off the device immediately and contact your dealer for service AN Caution Only use accessories and original spare parts recommended by manufacturer Only initiate dispensing if it is safe to do so Do not use the device to process samples with flammable contents This unit is not designed to be explosion proof For all dispensing tasks make sure that you are not endangering yourself or anyone else Do not expose the device to Ultra Violet UV light The lid may craze and crack under such exposure If liquid has penetrated the inside of the housing have the inner parts of the device repaired by only by service partners of manufacturer Contact your responsible sales office before returning a product After operation clean the device and unplug the power if it will not be used for extended periods e 19 2 Introduction
21. 30ml 5 seconds Dispense Speeds 25 30ml 5 seconds Gravity dispense Battery Capacity 3 6V 800mA Charging Time Approx 2 hours Operation Period More than 8 hours of Continuous use Number of charge Approx 500 times cycles Filter 290 L x 520 D x 298 H 220g 20 6 Parts of the LEVO PLUS Aspirating Dispansing speed level bar Rechageable Battery compartment Housing ABS ee LEVO PLUS Electric Pipette Filler LCD Display n EPF 3000 Adjustment Button Membrane filter di Remained battery Aspirating Button power level bar ABS OPipette adapter Silicone d Dispensing Button ABS Connector socket Charging plug Aspirating cone ABS Power supply Fig 1 7 Storage The LEVO PLUS can be stored in a wall holder Fastening the wall holder Clean the fastening point on the wall remove the protective foil S Press the wall holder firmly against the wall IL Removing the wall holder Pull the holder to one side to remove it from the wall Remove the fastening strip with the aid of ZZ commonly used solvents 4 LEVO PLUS Electric Pipette Filler EPF 3000 N Fig 2 The LEVO PLUS should not be stored for a long period of time without removing the pipette It is recommended to disconnect the LEVO PLUS from the AC adapter if the unit is not used for a lengthy period of time 21 8 Charging Before the first startup the battery
22. Reduce operating time Battery worn Replace battery 25 13 Warranty Statement The warranty for the device is 12 months from the date of purchase During this period the device will be repaired or exchanged without charge Warranty is void on devices with damaged manufacture s number damaged seal or damage due to improper use storage or transport of device or service by unauthorized persons CERTIFICATED OF SALE OF EQUIPMENT Name of company Address Model Number Description Serial Number Date of Sale 26 113 0033 3 6 7 TEL 03 5842 4161 FAX 03 5842 4177 E mail tokyo Ims coJjp 001 0011 11 3 1 1 TEL 011 707 7360 FAX 011 707 7361 E mail sapporo Ims co jp T980 0821 1 10 23 1 A TEL 022 221 3521 FAX 022 221 3521 E mail sendai lms co jp T305 0853 438 39 TEL 029 839 2237 FAX 029 838 2273 E mail tsukuba lms co jp T410 0043 7 1 TEL 055 920 2455 FAX 055 920 2457 E mail numazu lms co jp T485 0054 23 TEL 0568 76 8861 FAX 0568 76 8876 E mail nagoya ms coJp 7607 8184
23. prevent a loss of vacuum Spare adapters can be ordered from LMS or your local distributor 291020 Standard pipette adapter for EPF 3000 290008 Standard aspirating cone for EPF 3000 712912 None Sterile filter A The LEVO PLUS cannot be operated without a filter Wetting of filter due to overfilling will slow or prevent fluid movement If overfilling occurs change the filter immediately Only use the original filters supplied by the manufacturer 11 3 Changing the battery If the battery need to replaced follow these steps to replace the battery Take the lid off the battery compartment to expose the battery compartment Fig 9 Disconnect the plug of the new Li ion battery to the instrument Fig 10 Connect the plug of the new Li ion battery to the instrument Fig 10 Replace the battery compartment lid Dispose of the battery appropriately Li ion Batt H ee Connector Liion Battery f Fig 9 Fig 10 A Only use the original battery supplied by the manufacturer 17000205 Lithium ion Battery for EPF 3000 17400032 Power Supply for EPF 3000 12 Trouble Shooting Reduced aspiration capacity or Filter blocked Dirty or Replace the filter the Levo Plus blocked damaged Battery low Recharge Pipette drips Pipette not securely attached Reattach Silicon adapter or aspiration Reassembly change silicone cone loose adapter Silicone adapter or pipette Replace damaged
24. ING E EE EEEE 10 5 Symbolo ine motor DIOCKOGL in enea ena 10 6 Other pipetting recommendation 11 Maintenance 11 3 Changing the battery 12 Trouble shooting 16 1 Safety 3 Read the manual before using the Electric Pipette Filler Improper handling may cause a serious hazard resulting in personnel injury N Warning or death Improper handling may cause a serious hazard resulting in personnel injury A Caution or damage to equipment or buildings 3 Meanings of symbols Caution Warning Q Refrain from doing this o Follow all Instructions amp Do Not Touch Observe the national regulations for handling these substances the biological security level of your laboratory the material safety data sheets and manufacturer s application notes Wear personal protective equipment Insert the plug securely into a wall socket Loose connections result in excessive heat generation to the device and may cause arcing to occur at the connection Before operation ensure that the power cord is fully extended Keep the cord away from heat sources and do not place any objects on any part of the cord Q Avoid using multi point extension power cords Qo Follow the instructions regarding hygiene cleaning and decontamination of time S Disconnect the power supply plug if the unit is not going to be used for an extended period 17 ES Installing the device A N Warning Do not install the device where it can get dam
25. V 110928 Operation Manual Model EPF 3000 LEVO PLUS Electric Pipette Filler 9001 13485 C ISO CERTIFIED 2 LEVO PLUS Electric Pipette Filler 5 EPF 3000 LMS LMS CO LTD E 2 oO On oo m 10 11 9 3 9 4 10 1 O Oo O 00 00 00 00 00 4 4 O0 O1 ON c LE M ERLE
26. ing cone and the pipette from the top end of the pipette 10 3 Aspiration Select a speed and fill the pipette by pressing the aspirating button Fill the pipette just above the desired level Remove the pipette from the sample container by drawing it up against the inside wall of the container Adjust the volume of the sample by pressing the dispensing button until the meniscus is at the required level Fig 6 10 4 Dispensing The LEVO PLUS offers two different dispensing modes f the dispensing button is pressed only up to a point where a check can be felt the dispensing function will be based on the force of gravity and the liquid will simply flow out Pressing the dispensing button further down engages the motor and activates the blow out function X Finger pressure can be varied to fine tune the speed within each mode 23 10 5 Symbol of the motor blocked Fig 7 There is the symbol that indicates the motor is blocked on the LCD display The symbol appears when the motor is blocked of the battery is low at the same time the control circuit intelligently raise the power demand qt try to make the motor run 10 6 Other pipetting recommendation AN Use the instrument within the limits of its chemical resistance Never use with highly flammable liquids Observe the reagent manufacturer s safety information AN Never use the instrument in an atmosphere with a danger of explosion AN Never u
27. must be charged 10 hours in the LEVO PLUS pipette controller Allow the unit to charge anywhere from 2 to 3 hours later Before connecting the AC adapter to the electrical outlet check that its voltage setting corresponding to the voltage of your electrical outlet Connect the AC adapter to the electrical outlet as well as the electrical fitting at the base of the handle of the LEVO PLUS AN The LEVO PLUS should only be charged with the AC adapter provided The icon on the LCD display indicates the level of battery charge the more bars the greater the charge Special circuitry that makes it impossible to overcharged or partially charged at any convenient time 9 LEVO PLUS Description 9 1 Operating Button The LEVO PLUS has two operating buttons located at the front of the handle The upper button enables aspiration for as long as the button is held down The lower button allows for dispensing The aspiration and dispensing speeds can be fine tuned during operation by applying varying finger pressure to the operation buttons 9 2 Speed Adjustment button The speed adjustment button is located at the upper part of the handle The desired speed is set by push the speed adjustment button 9 3 Aspirating cone and pipette adapter The pipette adapter provided with the LEVO PLUS allows the user of all standard plastic and glass pipettes graduated and non graduated including Pasteur Pipettes The pipettes adapter of the LEVO PLUS consi
28. p or wet Do not use the device in potentially explosive atmosphere Do not operate the device in rooms where work is being carried out with explosive substances Do not use the device to process any substances which could create an explosive atmosphere Do not use the device near a heat source or where temperatures are elevated Do not operate the device when temperatures fall below 4 C and rise above 45 C Do not use the power supply when signs of damage are evident and particularly if the power cable is damaged OOIOO Do not use any primary cells Do not charge the Lithium ion rechargeable batteries outside of the device Do not connect the device to the power supply without the rechargeable batteries inserted Do not disassemble or modify the rechargeable battery Never pierce crush or throw the rechargeable battery Do not touch leaky rechargeable batteries Do not use any damaged rechargeable batteries Only use the supplied power supply for charging the device Only connect the power supply to voltage sources that correspond to the information on the identification plate regarding the power supply Only use the rechargeable batteries supplied Dispose of damaged rechargeable batteries in accordance with legal regulations Do not use this device where there are flammable or corrosive vapors S Install the device in a well ventilated place Insufficient ventilation may result in breakdown
29. se force with the LEVO PLUS AN Should the instrument fail to function properly stop pipetting and check the Trouble shooting section 11 Maintenance The LEVO PLUS has been designed for easy in house maintenance However Manufacturer also provides complete servicing and repair including a service report and a performance certificate Please return your LEVO PLUS to the local representative for repair Before returning it make sure that it is free from all contamination Please advise the service representative of any hazardous materials which may have come to contact with your LEVO PLUS 11 1 Decontamination To decontaminate lightly spray the outside of the LEVO PLUS with the decontamination spray and wipe dry with a clean cloth 11 2 Changing the aspirating cone pipette adapter and filter Fig 8 To change the aspirating cone pipette adapter and filter rotate the aspirating cone anticlockwise and full out the aspirating cone and the pipette Membrane filter adapter The filter can be removed by simply PIEN pulling it out once the aspirating cone and the pipette adapter have been disengaged Pipette adapter Position the new filter with the colored side Silicone upwards To reassemble insert the adapter and aspirating cone and twist the nose cone gently clockwise Acnmiratimm cane ASpirating cone A Fig 8 24 tt is recommended too change the silicon adapter every six months or when necessary to
30. sts of the aspirating cone and pipette adapter The pipette adapter enables a pipette to fit securely in place Thus creating a proper vacuum level and preventing leakage 9 4 Filters Removing the aspirating cone exposes a hydrophobic filter 0 45 micron located at the top of the aspirating piece The filter protects the LEVO PLUS from accidental over aspirations It is strongly recommended to use only the original filter supplied by the manufacturer with the LEVO PLUS The LEVO PLUS cannot be operated without a filter Wetting of filter due to overfilling will slow or prevent fluid movement If overfilling occurs change the filter immediately 10 Operating 10 1 Setting the operating speed Button at the upper part of the handle allows you to set Aspirating Dispansing speed level bar your aspiration and dispensing speeds fig 4 Eight speeds are available for each function simply push for faster and for slower Your selection will be Remained battery Pa displayed on the LCD power level har The LEVO PLUS can self regulate the aspiration and Fig 4 dispensing speeds by circuit feedback 22 X The aspiration and dispensing speeds can be fine tuned during operation by applying a varying amount of finger pressure to the operating buttons 10 2 Inserting a pipette Gently push a pipette into the silicones adapter and ensure that it fits securely To insert the pipette safely hold the LEVO PLUS from above the aspirat

Download Pdf Manuals