Home

Invacare® Etude Plus

image

Contents

1. 4 1 Mounting dismounting the steel side rail The side rail must be mounted with the release system at the head Wi end of the bed li L li Mounting The fork links on the side rail must be mounted according to the io CA instruction on the side rail Tighten the side rail with the 2 finger screws 2 32 cm gt Dismounting Loosen the 2 finger screws and remove the steel side rail 4 2 Mounting dismounting the Line and Britt V side rails Warning To avoid entrapment suffocation or accidental fall accidents from the mattress support it is essential that the gliding shoes be correctly guided into the bed end rails Adjust the side rail bars by hand to ensure they are mounted correctly Safety Make sure that the straps between the rails are not damaged or loose Mounting l Mount one end at a time Lift the upper bar the release buttons must face up outwards A 2 Press the locking pin at the end of the side rail with a finger 3 All three gliding shoes at the end of the bars are guided into the bed end rail until the lower bar has been locked thereby preventing the side rail from falling down B 4 Repeat points 2 and 3 when mounting the other end of the side rail Dismounting l Lower the side rail 2 Dismount one end at a time Lift the lower bar so that the spring paw
2. 10 2 2 Montage des Bettes va we REENERT sea CEA ees 11 2 3 Verkabelung lt 4 06400085 en an dikl ala ACC 12 2 4 Demontage des 13 e Bedienung des lt 14 3 1 Harndbediontell u nn een 14 3 2 Bedienung der 15 3 3 Anpassung der 15 e Zubeh rteile x www ud ew ROC ROCCO d AE en 16 4 1 Montage Demontage der Stahlseitengitter kk kk kk k 16 4 2 Montage Demontage der Seitengitter Line und Britt 17 4 3 Bedienung der Seitengitter Line und 18 AA Aufrichter suada an 19 4 5 Montage der Liegefl chenverl ngerung elles 19 406 Matratze a ug xx ell X FAX QE EP d ER a 20 4 7 Transportsicherung 21 s Bestellnummern des Zubeh rs 22 Reinigung und Wartung 6600 592404 6s 08 se e e e ow SEN e e e e e e e e e e e e e e ee en s 23 6 1 REMGUNG ss aud e EE aye RARE ERR al EN 23 6 2 ssa 3 a k ka a ran 24 0 3 Wartung EE E O 25 GA Schmierplan i sesa EEN Soe EEN Ee 25 Elektrisches System saos e us s k 1 E l sok a AER A a 26 7 1
3. Es kann zu elektromagnetischen St rungen zwischen dem Bett und anderen elektrischen Produkten kommen Zur Verringerung oder Eliminierung solcher elektromagnetischen St rungen erh hen Sie den Abstand zwischen dem Bett und den anderen Produkten oder schalten diese aus Dieses Pflegebett kann zusammen mit medizinischen elektrischen Ger ten verwendet werden die mit dem Herzen intrakardial oder mit den Blutgef en intravaskul r verbunden sind sofern die folgenden Punkte beachtet werden Das Pflegebett muss mit einer Anschlussm glichkeit f r den Potenzialausgleich versehen werden die mit dem hinten in dieser Gebrauchsanweisung angegebenen Symbol gekennzeichnet ist Medizinische elektrische Ger te d rfen nicht an den Metallteilen des Betts Seitenleisten Hubvorrichtung Tropf halterung Bettenenden etc befestigt werden Das Netzkabel der medizinischen elektrischen Ger te muss von Zubeh rteilen und beweglichen Teilen des Betts ferngehalten werden Stellen Sie sicher dass sich keine Objekte 7 B M bel Fensterfl gel oder Lagerbeh lter unter ber oder in der Nahe des Bettes befinden die die Bewegung des Bettes oder der Matratzenauflage einschr nken k nnten Senken Sie das Bett stets auf die unterste Position ab bevor Sie den Patienten unbeaufsichtigt im Bett lassen e e Das berrollen des Netzkabels kann mit Gefahren verbunden sein 1 Achten Sie darauf dass das Netzkabel nicht in die beweglichen Teile
4. Die nach erfolgreicher Absolvierung des Endtests bei dem alle beweglichen Teile Motoren und Laufrollen gepr ft werden angebrachte QA Nummer best tigt die Qualit t des Produkts Zur Identifizierung des Produkts beachten Sie bitte die Angaben auf dem Typenschild Entspricht das Produkt nicht den Qualit tsanspr chen von Invacare wird es vernichtet Sollten wider Erwarten Probleme mit dem gelieferten Produkt auftreten so wenden Sie sich bitte an Ihren Invacare Handler Auf der hinteren Einbandau enseite dieser Bedienungsanleitung finden Sie entsprechende Kontaktinformationen Invacare beh lt sich das Recht vor Produktspezifikationen ohne vorherige Ank ndigung abzu ndern 1 3 Typenschild Aufkleber und Symbole Werden keine erforderlichen Ma nahmen zur Gefahrenabwehr getroffen besteht die M glichkeit von Sach und WARNUNG Dieses Symbol warnt vor Gefahren A Personenschaden HINWEIS Dieses Symbol weist auf wichtige Informationen und Richtlinien hin e ANWEISUNG Verweis auf die Bedienungsanleitung INVACARE EC HONG AS Bitergade 30K 27 panne Ce Elektrische Anschlusswerte Lawa des ors ETUDE PLUS 230V A 10 50 He Er Siehe Kapitel 7 bour 2 al m max 70VA NE mg 5 oef Symbole EF Siehe Kapitel und 7 6 Produktionsdatum P 1 4 Sicherheit und Warnungen Invacare bernimmt keinerlei V
5. Minimum bij matras van 16 cm 36 59 cm Maximum bij matras van 10 cm 42 65 4 5 De verlenging voor de matrasbodem bevestigen Haal het bed uit elkaar en verwijder de inzetstukken Bevestig de verlenging voor de matrasbodem aan het hoofd of het voeteneinde en monteer het bed opnieuw 4 6 Matras Veiligheidsaspecten met betrekking tot de combinatie van zijhekken en matras Voor een optimale veiligheid dienen de minimum en maximummatrasmaten in de tabel in acht te worden genomen wanneer het bed in combinatie met zijhekken wordt gebruikt De verticale afstand tussen de bovenkant van de matras en de bovenkant van het zijhek moet minimaal 22 cm zijn om de kans dat de gebruiker over het zijhek heen kruipt en zich door een val ernstig kan verwonden zo klein mogelijk te houden De maximumma trashoogte in combinatie met een bepaald type zijhek wordt in de tabel vermeld Om te voorkomen dat het hoofd bekneld kan raken tussen de binnenkant van het zijhek en de matras met mogelijk verstikking tot gevolg moet er altijd een maximale tussenruimte worden gehanteerd Met name bij het gebruik van zeer dikke matrassen of zachte matrassen lage dichtheid of bij een combinatie van deze twee is het van groot belang om rekening te houden met dit risico De minimummatrasbreedte en lengte in combinatie met een bepaald type zijhek wordt in de tabel vermeld 20 Scala Basic 2 Scala Basic Plus 2 Scala Medium 2 Scala Decubi 2 Line zijhek matrasbo
6. kV differentiaal mode kV differentiaal mode De kwaliteit van de netstroom moet overeenkomen met die van een commerci le of ziekenhuisomgeving IEC 61000 4 5 2 kV common mode 2 kV common mode lt 5 U lt 5 U gt 95 dip in U gt 95 dip in U Spanningsdips wen De kwaliteit van de netstroom moet overeenkomen korte 40 U 40 U met die van een commerci le of ziekenhuisomgeving onderbrekingen 60 dip in U 60 dip in U Als de gebruiker van het medisch bed ETUDE en pannings voor 5 cycli voor 5 cycli PLUS continue beschikbaarheid vereist gedurende variaties op 70 U 70 U netspanningsonderbreking wordt aangeraden netspannings 30 dip in U 30 dip in U het bed van energie te voorzien met een inputlijnen voor 25 cycli voor 25 cycli noodstroomvoorziening UPS Uninterruptable Power Supply of een accu IEC 61000 4 11 5207 M m idi gt 95 dip in U gt 95 dip in U voor 5 sec voor 5 sec 29 Immuniteitstest IEC 60601 testniveau Niveau van Elektromagnetische omgeving richtlijn overeenkomst Wisselspannings frequentie Magnetische velden van de netspanningsfrequentie 50 60 Hz 3 Alm 3 Alm moeten op een niveau liggen dat kenmerkend is voor magnetisch veld een typische commerci le of ziekenhuisomgeving IEC 61000 4 8 OPMERKING U is de netspanning v r toepassing van de test Draagbare en mobiele RF c
7. Abfall bei U f r 0 5 Zyklen 40 U 60 Abfall bei U f r 5 Zyklen 70 U 30 Abfall bei U f r 25 Zyklen lt 5 U gt 95 Abfall bei U f r 5 s lt 5 U gt 95 Abfall bei U f r 0 5 Zyklen 40 U 60 Abfall bei U f r 5 Zyklen 70 U 30 Abfall bei U f r 25 Zyklen lt 5 U gt 95 Abfall bei U f r 5 s Die Netzstromqualitat muss der einer typischen gewerblichen oder Krankenhausumgebung entsprechen Ben tigt der Anwender des Pflegebettes ETUDE PLUS auch bei Unterbrechungen der Stromversorgung Zugriff auf die Bettfunktionen wird empfohlen das Pflegebett ETUDE PLUS ber eine unterbrechungsfreie Spannungsversorgung oder eine Batterie zu betreiben 29 Immunitatstest IEC 60601 Testniveau Einhaltungsniveau Elektromagnetische Umgebung Anleitung Magnetfelder m alen Die St rfestigkeit gegen Magnetfelder gilt bei nischen Frequen 3 Alm 3 Alm Feldst rken wie sie in einer typischen gewerblichen zen 50 60 Hz em oder klinischen Umgebung auftreten k nnen IEC 61000 4 8 ANMERKUNG U bezeichnet die Nennnetzspannung Der Abstand zwischen tragbaren und mobilen HF Kommunikationsger ten und dem Pflegebett ETUDE PLUS einschlie lich s mtlicher Kabel darf den unter Verwendung der Formel f r die jeweilige Sendefrequenz errechneten Mindestabstand nicht unterschreiten Leitungsgef hrte Empfohlener Mindestab
8. des Bettes gelangt Ziehen Sie den Netzstecker aus der Steckdose bevor Sie das Bett bewegen Die Kabel m ssen so angebracht werden dass sie nicht in Kontakt mit dem Boden gelangen k nnen und dass sie die Laufrollen nicht blockieren Wir empfehlen das Netzkabel am daf r vorgesehenen Haken zu befestigen siehe Abbildung 8 1 5 Garantie Die Garantie erstreckt sich auf s mtliche nachweislich bereits vor der Auslieferung bestehenden auf Material und Produktionsfehler zur ckzuf hrende M ngel und gilt f r einen Zeitraum von zwei Jahren ab Lieferdatum Alle Produktionsfehler und sonstigen Mangel m ssen unverz glich gemeldet werden Invacare steht es frei die m ngelbehaftete Komponente zu reparieren oder auszutauschen Die von Invacare einger umte Garantie deckt keine zus tzlichen Kosten ab Transport Verpackung Arbeitsaufwand sowie sonstige Aufwendungen gehen zu Lasten des Kunden In den folgenden Fallen gelangt die Garantie nicht zur Anwendung Bei Transportsch den die dem Frachtf hrer nicht sofort bei Anlieferung gemeldet werden Bei durch nicht autorisierte Werkstatten Personen durchgef hrten Reparaturen Bei normalem Verschlei von Komponenten Bei vors tzlich oder durch unsachgerechte Verwendung des Bettes herbeigef hrten Besch digungen 2 Anlieferung des 5 2 Komponenten des Bettes e Kontrollieren Sie die Verpackung Gehen Sie wie in den Lieferungsbedingungen erl utert vor wenn das Be
9. 3 Motor cable is damaged 4 Control unit defective I Control unit defective 2 Hand control box defective I Hand control box defective 2 Control unit defective Motor damaged 27 1 Connect mains 2 Replace the control unit 3 Replace the control unit I Push the motor plug right into control unit 2 Replace the motor 3 Replace the cable lace the control unit I Replace the control 2 Replace the hand control box I Replace the hand control box 2 Replace the control unit Replace the motor 7 2 Electo Magnetic Compliance Guidance and manufacturer s declaration electromagnetic emission The medical bed ETUDE PLUS is intended for use in the electromagnetic environment specified below The customer or the user of the bed should assure that it is used in such an environment Emissions test Compliance Electromagnetic environment guidance RF emissions The medical bed ETUDE PLUS uses RF energy only for its internal function CISPR 11 Group Therefore its RF emissions are very low and are not likely to cause any interference in nearby electronic equipment partly emissions The medical bed ETUDE PLUS is suitable for use in all establishments including Class B domestic establishments and those directly connected to the public low voltage CISPR 11 partly power supply network that supplies buildings used for domestic purposes Harmonic emissions C
10. 37 0 37 0 74 1 17 1 17 2 33 10 3 69 3 69 7 38 100 11 67 11 67 23 33 F r Sender deren maximale Nennausgangsleistung in dieser Tabelle nicht enthalten ist kann der empfohlene Mindestabstand d in Meter mit Hilfe der Gleichung in der entsprechenden Spalte abgesch tzt werden Hierbei ist P die maximale Nennausgangsleistung des Senders in Watt Herstellerangabe HINWEIS Bei 80 MHz bzw 800 MHz ist der Mindestabstand des jeweils h heren Frequenzbereichs anzuwenden HINWEIS 2 Diese Richtlinien werden m glicherweise nicht allen Situationen gerecht Die Ausbreitung elektromagnetischer Felder wird durch Absorption und Reflektion durch Bauten Objekte und Personen beeinflusst 32 8 Technische Spezifikationen 8 1 Abmessungen Alle Abmessungen sind in Zentimeter cm angegeben Alle Winkel sind in Grad angegeben Alle Abmessungen und Winkel sind ohne Toleranzen angegeben Invacare beh lt sich das Recht vor die angegebenen Abmessungen und Winkel zu ndern amp Etude Plus Untere Position Obere Position E ER D 158 198 4 sectioned 85 124 55 56 Ma e der Liegefl che 90 x 200 25 70 18 13 28 33 8 2 Transport und Lagerbedingungen Umgebungsbedingungen Relative Temperatur Luftfeuchtigkeit Luftdruck 10 C 20 700 hPa 50 75 1060 hPa 5 20 700
11. 4 4 Aufrichter Positionieren Sie den Aufrichter so dass der Griff ber dem Bett schwebt Wird der Griff belastet w hrend der Aufrichter aus dem Bett geschwenkt ist kann das Bett umkippen Montage I Entfernen Sie den Stopfen aus dem f r die Aufnahme des Aufrichter vorgesehenen Rohrst ck am Kopfteil des Bettes 2 SetzenSie den Aufrichter in das daf r vorgesehene Rohrst ck ein und fixieren Sie den Aufrichter mit der Knebelschraube Anpassen der H he des Aufrichtergriffs L sen Sie das Seil siehe Abbildung A 2 Der Aufrichtergriff kann nun auf die gew nschte H he eingestellt wer den 3 Dr cken Sie das Seil zusammen siehe Abbildung B und kontrollieren Sie durch Zug am Griff dass das Seil in der Seilklemme einge klemmt ist Abstand zwischen Aufrichter und Matratze Minimum bei l6 cm Matratzen 36 59 cm Maximum bei 10 cm Matratzen 42 65 4 5 Montage der Liegeflachenverlangerung Zerlegen Sie das Bett und entfernen Sie die Eins tze Montieren Sie die Liegeflachenverlangerung entweder am Kopf oder am Fu ende der Liegeflachenauflage und setzen Sie das Bett wieder zusammen 9 4 6 Matratze Sicherheitsaspekte m glicher Kombinationen von Seitengittern und Matratzen Zur Sicherstellung des maximal m glichen Sicherheitsniveaus ist bei Verwendung des Bettes in Kombination mit Seitengittern auf die Einhaltung der in der Tabelle angegebenen Mindest und H chstma e f r Matratzen zu achten
12. 40 75 1060 hPa Beachten Sie bitte dass sich bei niedrigen Temperaturen gelagertes Bett vor der Verwendung zun chst an die in der Umgebung in der es verwendet werden soll vorherrschenden Bedingungen anpassen muss 34 Invacare Etude Plus USER MANUAL GB GEBRAUCHSANWEISUNG DE GEBRUIKSAANWIJZING NL Inhoud Algemene informatie sse x en 4 I I Gebruik van bet products uns doe e e eee e e ees 4 1 2 CertifiGe ril g 44595065505 RECEN u a 5 LA Labels en symbolen 1 b OA aw RC ORE van 6 1 4 Veiligheid en lt 7 l5 Garantie san eve wer a evans 9 Ontvangst van het bed 10 2 1 Onderdelen van het bed ccc cece ccc cece e e cece e ee e e ee ee ee 10 2 2 Montage van bet bed wu ee rn 11 2 3 vices c om a RC EE ay 12 2 4 Demontage van het 13 e Bediening van het bed am un eels we as 14 3 De bandbedienihig usus mn REA WERL RC Re 14 3 2 De zwenkwielen met 15 3 3 Het beengedeelte aanpassen 15 gt ACCOSSOIF GS assen u oa 16 4 1 Het stalen zijhek monteren of verwijderen leere 16 4 2 De Line en Britt V zijhekken monteren of ver
13. Bedden met een kantelfunctie kunnen niet worden goedgekeurd volgens EN 1970 2000 e Mechanisch is het Etude Plus bed goedgekeurd volgens IEC 60601 2 52 e Het Etude Plus bed is goedgekeurd door T V en voorzien van de T V markering Het Etude Plus bed heeft een risicoanalyse ondergaan volgens EN ISO 14971 2001 03 TUV Invacare is gecertificeerd volgens DS EN ISO 9001 en ISO 13485 Hierdoor kunnen onze klanten er zeker van zijn dat ze altijd producten van een uniforme kwaliteit krijgen Production monitored Safety tested De kwaliteit van onze materialen en producten wordt gedurende het hele productieproces gecontroleerd Vlak v r de verpakking en de verzending wordt er bovendien nog een eindcontrole uitgevoerd Na de eindcontrole waarbij alle bewegende delen motoren en zwenkwielen worden gecontroleerd krijgt het product een kwaliteitswaarborgnummer Kijk op het productlabel om het product te identificeren Als het product niet voldoet aan de kwaliteitseisen van Invacare wordt het afgedankt Als er zich onverwacht toch een probleem voordoet met het geleverde product neemt u contact op met uw Invacare leverancier Op de achterkant van deze handleiding vindt u een lijst met adressen Invacare behoudt zich het recht voor productspecificaties zonder voorafgaande kennisgeving te wijzigen 1 3 Labels en symbolen A WAARSCHUWING dit symbool waarschuwt voor gevaren Als de benodigde maatregelen niet worden getroffen kan dit
14. Fehlersuche elektrisches System 27 7 2 Elektromagnetisches Vertr glichkeit EMV 28 Technische 33 8 1 Abmessungen s xxx k ka ERRORES EE TSAR al See al CN RR RR E 33 8 2 Transport und 34 B 3 GEWIENE sas EE eo anan un 35 Entsorgung ana 35 Herzlichen Gl ckwunsch Wir begl ckw nschen Sie zu Ihrer Entscheidung f r das Pflegebett Invacare Etude Plus Das zerlegbare Pflegebett Etude Plus von Invacare ist das speziell f r die h usliche Pflege entwickelt worden Das Etude Plus Bett kombiniert Handhabungskomfort mit guter Funktionalit t Bitte lesen Sie die gesamte Bedienungsanleitung durch bevor Sie das Bett erstmalig einsetzen F r Fragen zu Anwendung und Wartung stehen wir Ihnen jederzeit gerne zur Verf gung Die Lagebezeichnungen links und rechts beziehen sich auf eine Person die auf dem R cken im Bett liegt Beachten Sie bitte dass diese Bedienungsanleitung f r Ihr Bett m glicherweise irrelevante Abschnitte enth lt da sie s mtliche zum Zeitpunkt der Drucklegung erh ltlichen Module abdeckt 1 Allgemeine Informationen I I Verwendung des Produkts Das Etude Plus Bett wurde f r die h usliche Pflege entwickelt und bietet dem Patienten komfortable Sitz und Liegepositionen und der
15. Handbedienteil HL80 optional besitzt den Schutzgrad IPx4 Ziehen Sie den Netzstecker aus der Steckdose bevor Sie das Bett bewegen Das Kabel darf w hrend des Transports nicht in Kontakt mit dem Boden und den Laufrollen kommen e Ger uschpegel 45 bis 50 dB A e Die Matratzenauflage besitzt einen Einstellbereich von 40 bis 80 cm alternativ 33 bis 73 cm Der Winkel zwischen der Unterschenkelsektion und der Horizontalen ist zwischen 0 und 15 einstellbar 1 2 Zertifizierungen Das Etude Plus Bett tr gt die CE Kennzeichnung entspricht also den einschl gigen Anforderungen der Medizinprodukterichtli nie 93 42 EWG Das Etude Plus Bett wurde nach EN 1970 2000 getestet und zugelassen Betten mit Kippfunktion k nnen nicht nach EN 1970 2000 zugelassen werden e Hinsichtlich seiner mechanischen Konstruktion wurde das Etude Plus Bett nach 60601 2 52 zugelassen Dem Etude Plus Bett wurde nach entsprechenden Tests das TUV Priifzeichen verliehen Das Etude Plus Bett wurde einer Risikoanalyse nach EN ISO 14971 2001 03 unterzogen Invacare ist nach DS EN ISO 9001 und ISO 13485 zertifiziert wodurch sichergestellt ist dass unsere Kunden jederzeit mit Produkten gleichbleibend hoher Qualitat beliefert werden Production monitored Safety tested Unsere Materialien Produkte werden in s mtlichen Phasen des Produktionsprozesses kontinuierlich qualitatskontrolliert Zus tzlich erfolgt vor Verpackung und Versand ein Endtest
16. Kabel des Kopfteilmotors in die vier Haken am Kopf teil ein Fixieren Sie den Sicherheitsclip an der Steuerungseinheit 2 4 Demontage des Bettes e Nehmen Sie die Seitengitter und den Aufzugsb gel ab Bringen Sie das Bett in die unterste Position und alle Sektionen der Liegeflache in horizontale Stellung e Ziehen Sie das Netzkabel aus der Steckdose Wickeln Sie das Netzkabel auf und h ngen Sie es an den Haken am Kopfteil des Bettes L senSie alle Motorstecker von den Motoren das R ckenleh nenmotorkabel Kabel nicht l sen Demontieren Sie den Sicherheitskamm mithilfe eines geeigneten Werkzeugs z B Schlitzschraubendreher von der Steuerungsein heit Ziehen Sie die Kabel des Kopfteil des FuBteil und des Beinsekti onsmotors heraus e L sen Sie die Liegefl che von Kopf und FuBteil Trennen Sie Kopf und Fu ende der Liegefl che voneinander 3 Bedienung des 5 3 1 Handbedienteil AUF AB IW ay Sitzposition A See Se lt amp a Ss EER Schenkelteil gt lt H henverstellung des Bettes Gd gt Schl ssel zum Sperren und Entsper ren der Elektrischen Funktionen Zum Sperren bzw Entsperren der Hand steuerungsfunktionen den Schl ssel unter lt jeder Taste einf hren Pri HL 80 mit integrierter ACP Funktion HB 80 Handbedienteile mit Schr gstellungsfunktion Tilt k nnen von Invacare bestellt we
17. Um auszuschlieBen dass der Patient das Seitengitter berklettern und sich bei einem Sturz m glicherweise schwere Verletzungen zuzieht ist ein vertikaler Mindestabstand von 22 cm zwischen der Oberkante der Matratze und der Oberkante des Seitengitters einzuhalten Die Tabelle gibt Aufschluss ber die maximal zulassige Matratzendicke bei Verwendung der verschiedenen Seitengitter Um ein Einklemmen des Kopfs zwischen Seitengitter und Matratze Erstickungsgefahr zu verhindern muss ein Sicherheitsmaxi malabstand eingehalten werden Insbesondere bei sehr dicken und oder sehr weichen Matratzen geringe Dichte ist diesem Risiko besondere Beachtung zu widmen Die Tabelle gibt ebenfalls Aufschluss ber die Mindestbreite und l nge der Matratze bei Verwen dung der verschiedenen Seitengitter 20 Scala Basic 2 Scala Basic Plus 2 Scala Medium 2 Scala Decubi 2 Seitengitter Line Liegeflachen in unterer Position Seitengitter Line Liegeflachen in oberer Position Seitengitter Britt V Liegeflachen in unterer Position Seitengitter Britt V Liegeflachen in oberer Position 4 7 Transportsicherung Matratzen Matratzen Matratzen Matratzen Siehe Gebrauchsanleitung auf der Riickseite dieses Bedienungsanleitung 21 5 Bestellnummern des Zubeh rs Seitengitter Scala Baic 2 klappbar l PASE ege obe ines duce Orc ace e s pua nah nane ehe ale gc d 1528930 XXXX Scala Basic Plus 2 klappbar Paar ae 1529745 XXXX 5 Medi
18. is gemeld Reparaties die zijn uitgevoerd door onbevoegde centra en personen Normale slijtage van onderdelen Schade die moedwillig is toegebracht of die is ontstaan door onjuist gebruik van het bed 2 Ontvangst van het bed 2 1 Onderdelen van het bed Controleer de verpakking Zie de leveringsvoorwaarden als het bed tekenen van beschadiging vertoont De volgende onderdelen moeten worden geleverd Matrasbodem hoofdeinde 2 matrasbodemhaken 2 zijhekken hout of staal Matrasbodem voeteneinde Motor voor bed uiteinde Zwenkwielen Motor voor hoofdeinde Verlenging voor matrasbodem 10 of 20 cm optioneel Motor voor voeteneinde 0 2 bed uiteinden Handbediening HL80 HB80 40 ON og WNT Optioneel Optrekstang Transportbevestiging 2 2 Montage van het bed Matrasbodem 1 Plaats de twee inzetstukken in het hoofdeinde van de matrasbodem De inzetstukken moeten zodanig worden geplaatst dat het ene stuk verder uit de zijbuis steekt dan het andere Draai de twee duimschroeven losjes aan Duw het voeteneinde van de matrasbodem op de twee inzetstukken Zet het vast met twee duimschroeven Draai de twee duimschroeven aan het hoofdeinde opnieuw aan Draai de twee matrashandvatten van de rugleuning omhoog Draai het handvat van het beengedeelte omhoog Draai de vergrendelring aan de uiteinden van het bed naar de open positie Bevestig de matrasbodem aan de bed uiteinden en druk deze stevig op zijn ple
19. mattress 36 59 cm Maximum at 10 cm mattress 42 65 cm 4 5 Fitting the mattress support extension Disassemble the bed and remove the inserts Mount the mattress support extension on either head or foot end and A reassemble the bed 19 4 6 Mattress Safety aspects regarding combination of side rails and mattresses In order to obtain the highest possible safety level when using the bed in combination with side rails it is important to respect the minimum and maximum measures for mattresses stated in the table To mitigate the possibility of the user crawling over the top of the side rail with the risk of severe injury due to e g falling a mini mum vertical distance of 22 cm between the top of the mattress and the top of the side rail are to be respected The maximum mattress height in combination with a given side rail is stated in the table To prevent head entrapment between the inside surface of the side rail and the mattress with the risk of e g suffocation a safety maximum space has to be respected When especially very thick mattresses or soft mattresses low density or a combination of these it is important to focus on this risk The minimum width and length of mattresses in combination with a given side rail is stated in the table 20 Mattress Mattress Mattress Mattress Line side rail Mattress support 22 cm TEN 90 cm 200 cm platform in low position Line side rail Mattress support 15 cm ag 90 cm 200 cm platfor
20. with medically clean oil e g 50 order no 813239 NB The wooden side rails gliding system must not be lubricated with oil otherwise the wooden bars will move sluggishly Remove the mains plug from the socket before cleaning 25 7 Electrical system Voltage supply 230 V 10 50 Hz Max current input A Voltage output 24 V max 70 VA Intermittent periodic motor operation 1076 max 6 min h Protection class IPX6 Insulation class Il type B Alternating current Direct current The patient is not separated from the ground and the chassis Potential equalization d The bed is not provided with a mains switch so the mains plug is the only separation from the mains 26 7 Trouble shooting the electrical system Mains indicator does not light up Mains indicator lights up but the motor is not run ning The relay in the control unit makes a clicking noise Mains indicator lights up but the motor is not run ning No relay sound is heard from the control unit Control unit is in order except one direction on one channel Motor is running but the spindle does not move The motor cannot lift full load Motor noise but no movement of piston rod Piston rod operate inwards and not outwards I Mains not connected 2 Fuse in the control unit is blown 3 Control unit defective I Motor plug not pushed fully into the control unit 2 The motor is defective
21. 0 V 10 50 Hz Max Stromaufnahme Spannungsausgang 24 V max 70 VA Benutzungsintervall Dauerbetrieb der Motoren nicht zul ssig 10 max 6 min S Schutzklasse IPx6 Isolierung Klasse typ B o Wechselstrom Gleichstrom Der Patient ist nicht von Erde oder Masse getrennt Potentialausgleich d Das Bett ist nicht mit einem Netzschalter versehen der Netzstecker ist die einzige Trennm glichkeit vom Netz 26 7 1 Fehlersuche elektrisches System Netzkontrollleuchte leuchtet nicht I Nicht an Steckdose angeschlos An Steckdose anschlie en sen 2 Steuerungseinheit austauschen 2 Sicherung in der Steuerungsein 3 Steuerungseinheit austauschen heit durchgebrannt 3 Steuerungseinheit defekt Netzkontrollleuchte leuchtet aber Motor l uft nicht 1 Motorkabelstecker nicht voll I Motorkabelstecker vollst ndig in Relais in der Steuerungseinheit macht klickende st ndig in die Steuerungseinheit die Steuerungseinheit einstecken Ger usche eingesteckt 2 Motor austauschen 2 Motor defekt 3 Kabel austauschen 3 Motorkabel besch digt 4 Steuerungseinheit austauschen 4 Steuerungseinheit defekt Netzkontrollleuchte leuchtet aber Motor l uft nicht 1 Steuerungseinheit defekt 1 Steuerungseinheit austauschen Von der Steuerungseinheit sind keine Relaisger usche 2 Fernbedienung defekt 2 Fernbedienung austauschen zu h ren Steuerungseinheit bis auf eine Richtung eines Kanals I Fernbedienung defekt
22. I Fernbedienung austauschen intakt 2 Steuerungseinheit defekt 2 Steuerungseinheit austauschen Motor lauft aber die Motor l uft aber die Spindel bewegt sich nicht bewegt sich nicht Motor kann nicht die volle Last anheben kann nicht die volle Last anheben stange nach innen nicht nach au en Motor kann nicht ie volle Lascanheben defekt Motor austauschen 27 7 2 Elektromagnetisches Vertraglichkeit EMV Anleitung und Herstellererklarung elektromagnetische Emissionen Das Pflegebett ETUDE PLUS ist zur Verwendung in der nachfolgend definierten elektromagnetischen Umgebung vorgesehen Der oder Anwender des Bettes muss sicherstellen dass es in einer solchen Umgebung verwendet wird Emissionstest Einhaltung Elektromagnetische Umgebung Anleitung Das Pflegebett ETUDE PLUS nutzt HF Energie f r interne Funktionen Aus Gruppe diesem Grund sind die HF Emissionen sehr gering und verursachen aller Voraussicht CISPR 11 MP SOEN nach keine St rungen bei elektronischen Ger ten in der N he teilweise HF Emissionen Das Pflegebett ETUDE PLUS eignet sich f r die Verwendung in allen Arten von Klasse B Einrichtungen darunter Wohnbereiche und Umgebungen die direkt mit dem CISPR 11 ffentlichen Niederspannungsnetz zur Versorgung von Wohngeb uden verbunden teilweise sind Oberwellene missionen Klasse A IEC 61000 3 2 Spannungsfluktua tionen Flimmer m D
23. Invacare Etude Plus EN Bed User manual DE Bett Gebrauchsanweisung NL Bed Gebruiksaanwijzing This manual must be given to the user of the product Before using this product read this manual and save for future reference Yes you can Invacare Etude Plus USER MANUAL GB GEBRAUCHSANWEISUNG DE GEBRUIKSAANWIJZING NL Contents lt General information ss u EEN un 4 lI Product we r VOR eo mi 4 l2 Certification ss a swede EE Wi wl e El V EE EE 5 LA Labels and symbeals sea nn a an 6 1 4 Safety and Warnings assa s Aere Aer AEN 7 1 5 Warranty u erder ever HONS HERS 9 Receiving the bed sacs wav eer RO aaa 10 2 1 Parts of the bed nn a a nn 10 2 2 Assembly of the 4 649564 469 x n s l kl a n k en nen 11 23 ad CHER y 12 24 Dismantling the Beds somers e nn 13 Operating the bed ss s syn an u an 14 3 1 Operating of the hand control unit 14 3 2 Operating the braking castors 15 3 3 Adjustment of leg Section 15 5 Dorbe en l6 4 1 Mounting dismounting the steel side rail 16 4 2 Mounting dismounting the Line and Britt V side rails 17 4 3 Operation Line and Britt side 18 44 Lifting a an 19 4 5 Fitting the mattr
24. Pflegekraft eine ergonomische Handhabung Das Etude Plus Bett ist f r folgende Anwendungsgebiete vorgesehen Anwendungsgebiet 3 Langzeitpflege in einer medizinischen Einrichtung bei der eine medizinische Aufsicht erforderlich ist bei Bedarf eine berwachung erfolgt und im Rahmen medizinischer Verfahren verwendete medizinische elektrische Ger te dazu beitragen k nnen den Zustand des Patienten zu stabilisieren oder zu verbessern Anwendungsgebiet 4 Pflege im h uslichen Umfeld wobei medizinische elektrische Ger te eingesetzt werden um eine Verletzung Behinderung oder Erkrankung zu lindern oder zu kompensieren Das Pflegebett Etude Plus Bett ist f r den Wiedereinsatz geeignet ocd Bei Patienten von mehr als zwei Meter K rpergr Be wird die Verwendung einer Matratzen Z N 145 kg auflagenverl ngerung empfohlen Das maximal zul ssige Gewicht des Patienten betr gt 145 kg vorausgesetzt das Gewicht von Matratze 2 und Zubeh rteilen bersteigt 35 kg nicht maximale Traglast 180 kg ZA 180 kg Das Bett ist weder fiir Kinder unter 2 Jahren noch fiir psychiatrische Patienten vorgesehen Dar ber Beachten Sie die Beschrankungen f r die Verwendung in den Warnungen erw hnt Kapitel 1 4 4 gt e Die Verkabelung besteht aus flexiblen Kabeln die zwecks leichterem Austausch an beiden Enden mit Steckern verbunden sind Die Steuerungseinheit die externe Stromversorgung und die Motoren besitzen den Schutzgrad IPx6 e Das
25. WP d 2 WP d LL WP Vi Ei Ei 0 01 0 12 0 12 0 23 0 1 0 37 0 37 0 74 1 17 1 17 2 33 10 3 69 3 69 7 38 100 11 67 11 67 23 33 Voor zenders met een maximumuitgangsvermogen buiten het bovenvermelde kan de aanbevolen afstand in meters m worden geschat met gebruik van de vergelijking die van toepassing is op de zenderfrequentie waarbij P het maximumuitgangsvermogen in watts W is van de zender volgens opgave van de fabrikant OPMERKING 1 bij 80 MHz en 800 MHz zijn de daarboven gelegen frequentiegebieden van toepassing OPMERKING 2 deze richtlijnen zijn mogelijk niet in alle omstandigheden van toepassing Elektromagnetische straling wordt beinvloed door absorptie en reflectie van structuren objecten en mensen 32 8 Technische specificaties 8 1 Afmetingen Alle maten worden in cm vermeld Alle hoeken worden in graden vermeld Alle maten en hoeken worden zonder toleranties vermeld Invacare behoudt zich het recht voor de vermelde maten en hoeken te wijzigen Etude Plus 4 sectioned 85 124 55 56 25 70 18 13 28 33 8 2 Voorschriften voor transport opslag Omgevingsvoorwaarden Relatieve Atmoferische vochtigheid druk Opslag Van 10 C 20 700 hPa Tot 50 75 1060 hPa Temperatuur Bedrijf 5 C 2076 700 hPa 40 C 75 1060 hPa Als een bed bij een lage temperatuur opges
26. aae A a e Ro DDR RR arn ET N eh RR RR Ge DR 1449687 XXXX If a mattress support extension is used it is also possible to use an extended side rail XX XXXX means that colour wood type must be indicated contact sales company for further question Please only use original spare parts Spare parts lists and extra user manuals can be ordered from Invacare or homepage 22 6 Cleaning and Maintenance e e Personnel who have received the necessary instructions or training may only perform Service and maintenance of the bed 1 e With normal daily use service must be carried out according to the service schedule after 2 years use and thereafter every second year When relocating the bed service must be carried out according to the service schedule 6 1 Cleaning The bed does not tolerate cleaning in automatic washing plants or the use of water jet based cleaning equipment Please make sure the power plug is removed from the socket outlet before cleaning The bed should be washed down using a wet sponge cloth or brush Use ordinary household cleaning agents Never use acids alkalines or solvents such as acetone or cellulose thinner The hand control motors and control unit may be washed with brush and water but not with pressurized water Dry the bed after cleaning C SS NB All plugs must be installed during washing of the bed 23 6 2 Maintenance chart Service and maintenance of the Etude Plu
27. an 45 kg wegen of die kleiner zijn dan 150 cm Dit geldt ook voor personen die rusteloos zijn spasmen of verward zijn tenzij er een deskundige risicoanalyse heeft plaatsgevonden en deze is geaccepteerd Er kan gebruik worden gemaakt van een vei ligheidshoes die op de juiste wijze over de zijhekken is geplaatst Wanneer de zijhekken met de bijbehorende veiligheidshoes worden gebruikt moet worden gecontroleerd of de hoes goed past anders kan de pati nt bekneld raken Gussen de matrasbodem het zijhek en het beduiteinde en mogelijk stikken Pas op dat er geen vingers tussen de bewegende delen van het bed bekneld raken Elektromagnetische interferentie tussen het bed en andere elektrische apparaten kan voorkomen Vergroot de afstand tussen het bed en de betreffende apparaten of schakel deze uit om een dergelijke elektromagnetische interferentie te verminderen of te doen verdwijnen Dit verpleegbed kan worden gebruikt in combinatie met medische elektrische apparatuur die is verbonden met het hart intracardiaal of bloedvaten intravasculair op voorwaarde dat met de volgende punten rekening wordt gehouden Het verpleegbed moet worden voorzien van middelen voor een potentiaalvereffeningsverbinding aangeduid met een symbool getoond aan het eind van dit handboek Medische elektrische apparatuur mag niet worden vastgemaakt aan metalen hulpstukken van het bed zoals de zijhek ken hefstang infuusstang bed uiteinden enzovoort Het nets
28. an het bed aangesloten zijn 23 6 3 Onderhoudsschema Service en onderhoud aan het Etude Plus bed mag alleen worden uitgevoerd door mensen die hiertoe de juiste instructies of training hebben gekregen Bed id nr me Visuele inspectie van alle onderdelen van het bed 0 vervorming van plastic en of slijtage van gelaste verbindingen _ EES ES ES ES De Rastofix hulpstukken en de werking hiervan controleren TT Visuele inspectie van alle kasten beschadigingen TT Controleren of de voedingskabel en stekker intact zijn Controleren of de kabel goed loopt Alle overige kabels op beschadigingen controleren Controleren of deze kabels goed lopen De bevestiging en vergrendeling beweging van de zijhekken controleren La De wielen controleren veiligheid remmen en vrij rollen EE TE 24 6 3 Onderhoud V r het eerste gebruik Controleer of alle handmatige en elektrische onderdelen correct werken en zich in een goede staat bevinden Na 3 maanden Controleer of alle handmatige en elektrische onderdelen correct werken en draai bouten schroeven moeren enzovoort aan Om de twee jaar Er moet service worden uitgevoerd volgens het onderhoudsschema Zie paragraaf 6 2 Onderhoudsschema 6 4 Smering We raden u aan het bed als volgt te smeren l Draaipunten in matrasbodem en basisframe smeren met olie 2 Trekstaven van alle motoren smeren met olie Sy 3 Lagers en Rastofix hulpst
29. are De Etude Plus is het demontabele verpleegbed van Invacare dat speciaal is ontworpen voor verpleging in de thuissituatie Het Etude Plus bed biedt gebruiksgemak in combinatie met een goede functionaliteit Lees de volledige gebruikershandleiding voordat u het bed in gebruik neemt U kunt altijd contact met ons opnemen als u vragen hebt over het gebruik of het onderhoud van het bed Bij alle verwijzingen naar links of rechts wordt ervan uitgegaan dat een persoon op zijn rug in het bed ligt deze gebruikershandleiding betrekking heeft op alle bestaande modules de datum waarop dit document wordt gedrukt is het mogelijk dat niet alle gedeelten relevant zijn voor uw bed 1 Algemene informatie 1 1 Gebruik van het product Het Etude Plus bed is speciaal ontwikkeld voor verzorging in de thuissituatie Het bed biedt een comfortabele ziten ligpositie voor de pati nt Bovendien kan het bed ergonomisch worden bediend door de verzorger Het Etude Plus bed is bedoeld voor gebruik in de volgende situaties Toepassingsomgeving 3 langdurige zorg in een medische omgeving waar medische supervisie vereist is bewaking zo nodig be schikbaar is en elektrische medische apparatuur die bij medische procedures wordt gebruikt beschikbaar is om de conditie van de pati nt op peil te houden of te verbeteren Toepassingsomgeving 4 zorg die wordt verleend in een thuissituatie waarin elektrische medische od apparatuur wordt gebruikt voor
30. at the head end of the top frame Turn the two mattress handles of the backrest up Turn the handle of the leg section up Turn the locking ring on the bed ends to the position open Latch the mattress support to the bed ends and press firmly into position The attachement posts on the bed ends may not initially bottom out in bed rail slots The slots are wedges shaped to ensure a snug fit over the life of the bed 10 Make sure that the bed ends are in the same level It is possible to level the bed in high position A and low position B Il Turn the locking ring to the position lock 9 N 9S C The locking rings locks ensure that the mattress support is not acciden tally lifts clear of the bed ends Control Box The control box is latched to the backrest motor The control box is provided with a label with symbols showing where to connect the motors plugs e Backrest motor Thigh section s motor Bed end motor Hand control 2 3 Wiring In order to prevent the cables from being torn apart when activating the motors it is very important to follow the instructions below l Connect the cables of the bed end motors head and foot end directly to the control box 2 The plug of the thigh motor must be directed through the open ing of the supporter for the backrest motor and then be con nected to the control box 3 Connect the mains cable to the 230 V plug 4 Run the motors of th
31. bed can be used together with medical electrical equipment connedted to the heart intracardially or blood vessels intravascularly provided that following points are respected The medical bed should be equipped with means for potential equalization connection marked out by a symbol shown in the back of this manual Medical electrical equipment should not be fixed on the bed s metallic accessories such as side rails lifting pole drip rod bed ends etc The medial electrical equipment power supply cord should be kept clear if the accessories or any other moving part of the bed Make sure that there are nothing under over or near the bed that can limit the movement of the bed or the mat tress support such as furniture window frames and storage boxes Always lower the bed to the lowest position before leaving the patient in the bed unattended e It can be dangerous to roll over the mains cable e Do not bring mains cable into moving parts 1 e Disconnect the plug from the mains before moving the bed The cables must be mounted in such a way that they are kept clear of the floor and do not block the castors We recommend to mount the mains cable on the hook for this purpose see picture 1 5 Warranty The warranty covers all material and production defects for 2 years from the date of delivery provided it can be demonstrated that such defects were present before delivery All manufacturing faults or defects must be promp
32. chroevendraaier C 4 Pakdeonderste stang vast Laat het zijhek zakken totdat alle drie de stangen los zijn van het bed uiteinde 5 Herhaal stap 2 4omhetandere einde van het zijhek te verwijderen 4 3 De Line en Britt V zijhekken bedienen In sommige gevallen kan het zijhek zowel op halve hoogte als in de hoogste stand worden vergrendeld Normaal gesproken kan het Optillen zijhek echter alleen in de hoogste stand worden vergrendeld Omhoog trek de bovenste houten stang van het zijhek omhoog totdat de vergrendeling hoorbaar vastklikt Omlaag til de bovenste houten stang van het zijhek omhoog en druk de twee vergrendelringen tegelijk in Laat het zijhek zakken Ontgrendelen Laten zakken 4 4 De papegaai Plaats de papegaai zodanig dat de handgreep boven het bed komt te hangen Als de papegaai wordt gebruikt terwijl de handgreep buiten het bed hangt kan het bed kantelen Monteren lI Verwijder de plug uit de optrekstangbuis aan het hoofdeinde van het bed waar de optrekstang moet worden bevestigd 2 Plaats de optrekstang in de buis en zet deze vast met de duimschroef De hoogte van de handgreep van de optrekstang aanpassen 1 Maak het koord losser zoals in illustratie A 2 De handgreep kan nu worden aangepast tot de gewenste hoogte 3 Druk het koord samen zoals in illustratie B en trek aan de handgreep om te controleren of het koord vergrendeld is De afstand tussen de optrekstang en de matras
33. chultem Personal durchgef hrt werden Ident nr des Betts A TT Visuelle Begutachtung aller Teile des Betts plastische Verformung und oder Verschlei und Schwei n hte ES Peres mae emerat E LL Ee rower Ee TI 24 6 3 Wartung Vor Verwendung Uberzeugen Sie sich von der einwandfreien Funktion und dem sicheren Zustand aller mechanischen und elektrischen Teile Nach drei Monaten berzeugen Sie sich von der einwandfreien Funktion aller mechanischen und elektrischen Teile Ziehen Sie Bolzen Schrauben Mut tern usw nach Alle zwei Jahre Planm ige Wartung gem Wartungsplan siehe Abschnitt 6 2 6 4 Schmierplan Wir empfehlen die beweglichen Komponenten des Bettes entsprechend der folgenden Anweisungen zu schmieren 1 Drehpunkte der Matratzenauflage und des Grundgestells mit Ol schmieren 2 Zugstangen aller Motoren mit l schmieren LR 3 Alle Motorlager und Rastofix Fitting mit l schmieren KS O LJ Verwenden Sie fiir die Schmierung medizinisch reines Ol z B KEN WO 50 Bestellnummer 813239 Wichtig Das Gleitsystem der Holzseitengitter darf nicht mit Ol geschmiert werden andernfalls k nnen die Holzleisten nur schlep pend bewegt werden Ziehen Sie vor dem Reinigen den Netzstecker aus der Steckdose 25 7 Elektrisches System AnschluBspannung 23
34. cycle for 0 5 cycle sa 40 U 40 U Mains power quality should be that of a typical SEN 60 dip in 60 dip in U commercial or hospital environment If the user of the vola on for 5 cycles for 5 cycles medical bed ETUDE PLUS requires continued n SE Supply 70 U 70 U operation during power mains interruptions it is recommended that the medical bed ETUDE PLUS be powered from an uninterruptible power supply or a battery 29 Immunity test IEC 60601 test level Compliance level Electromagnetic environment guidance Power frequency 50 60 Hz magnetic field IEC 61000 4 8 3 A m 3 A m Power frequency magnetic fields should be at levels characteristic of a typical location in a typical commercial or hospital environment NOTE U is the a c mains voltage prior to application of the test level Conducted RF IEC 61000 4 6 Radiated RF IEC 61000 4 3 3 V m 3V 3 V m Portable and mobile RF communications equipment should be used no closer to any part of the EQUIPMENT medical bed ETUDE PLUS including cables than the recommended separation distance calculated from the equation applicable to the frequency of the transmitter Recommended separation distance de WE Vi d 80 MHz to 800 MHz 1 J WP 800 MHz to 2 5 GHz 1 30 Immunity test IEC 60601 test level Compliance level Electromagnetic environment gui
35. dance where p is the maximum output power rating of the transmitter in watts W according to the transmitter manufacturer and d is the recommended separation dis tance in metres m Field strengths from fixed RF transmitters as deter mined by an electromagnetic site survey should be less than the compliance level in each frequency range Interference may occur in the vicinity of equipment marked with the following symbol e NOTE At 80 MHz and 800 MHz the higher frequency range applies NOTE 2 These guidelines may not apply in all situations Electromagnetic propagation is affected by absorption and reflection from structures objects and people Field strengths from fixed transmitters such as base stations for radio cellular cordless telephones and land mobile radios amateur radio AM and FM radio broadcast and TV broadcast cannot be predicted theoretically with accuracy To assess the electromagnetic environment due to fixed RF transmitters an electromagnetic site survey should be considered If the measured field strength in the location in which the medical bed ETUDE PLUS is used exceeds the applicable RF compliance level above the medical bed ETUDE PLUS should be observed to verify normal operation If abnormal performance is observed additional measures may be necessary such as reorienting or relocating the medical bed ETUDE PLUS gt Over the frequency range 150 kHz to 80 MHz fie
36. de verzorging of behandeling van een verwonding handicap of ziekte Z N 145 kg Als de pati nt langer is dan 2 meter is het raadzaam een verlengde matrasbodem te gebruiken e Het maximumgewicht van de pati nt is 145 kg ervan uitgaande dat het gewicht van de matras en de 2 accessoires in totaal niet meer dan 35 kg bedraagt Veilig werklastgewicht max 180 kg EN 180 kg Het bed is niet bedoeld voor kinderen die jonger zijn dan 12 jaar en psychiatrische pati nten d Bovendien wees bewust van de beperkingen van het gebruik zoals vermeld bij de waarschuwingen hoofdstuk 1 4 4 Dekabels zijn flexibele kabels met stekkers aan beide uiteinden zodat ze eenvoudig kunnen worden vervangen Debesturingseenheid de externe stroomvoorziening en de motoren zijn beveiligd volgens IPx6 Als het bed is voorzien van een HL80 handbediening wordt het beveiligd volgens IPx4 e Haalaltijd de netstekker uit het stopcontact voordat het bed verplaatst Zorg ervoor dat de voedingskabel tijdens het trans port de vloer en de zwenkwielen niet raakt e Geluidsniveau 45 50 dB A Hetaanpassingsgebied van de matrasbodem is 40 80 cm of 33 73 cm De hoek tussen het onderbeengedeelte en het horizontale vlak kan worden aangepast van 0 tot 15 1 2 Certificering Het Etude Plus bed is voorzien van de CE markering Richtlijn medische hulpmiddelen 93 42 EEG Het Etude Plus bed is getest en goedgekeurd volgens EN 1970 2000
37. deinde van het bed SE Wi Li el Monteren De vorkkoppelingen op het onrusthek moeten volgens de instructie op de onrusthek worden gemonteerd io CA Zet het zijhek vast met de 2 vingerschroeven Verwijderen Draai de 2 vingerschroeven los en verwijder het zijhek 2 32 cm gt 4 2 De Line en Britt V zijhekken monteren of verwijderen Waarschuwing om ongelukken door bekneld raken verstikking of vallen te voorkomen moet het glijbeslag altijd op de juiste wijze in de rails van het bed uiteinde zijn bevestigd Pas de zijhekken met de hand aan om ervoor te zorgen dat ze goed worden gemonteerd Veiligheid zorg ervoor dat de banden tussen de rails niet beschadigd of los zijn Monteren A Monteer eerst de ene kant Til de bovenste stang op de ontgrendel knoppen moeten naar boven buiten wijzen A 2 Druk met een vinger op de vergrendelpin aan het uiteinde van het zijhek 3 De drie delen van het glijbeslag aan het uiteinde van de stangen wor den in de rail van het bed uiteinde gevoerd totdat de onderste stang vergrendeld is zodat het zijhek niet omlaag kan vallen B 4 Herhaal stap 2 en 3 om het andere einde van het zijhek te monteren Verwijderen Laat het zijhek zakken 2 Verwijder eerst de ene kant Til de onderste stang op zodat de veer pal zichtbaar is 3 Druk de pal in met een sleutel of s
38. demplatform in lage stand Line zijhek matrasbodemplatform in hoge stand Britt V zijhek matrasbodemplatform in lage stand Britt V zijhek matrasbodemplatform in hoge stand 4 7 Transporthaken Matras Matras Matras Matras Zie de instructies voor gebruik op de achterkant van deze handleiding 21 5 Artikelnummers van de accessoires Zijrail Scala Baic 2 opvouwbaar paar sid ean p a elle we e e pe a ah c d alos 1528930 XXXX Scala Basic Plus 2 opvouwbaar paar 1529745 XXXX Scala Medium 2 opvouwbaar paar 1530436 XXXX Scala Decubi 2 opvouwbaar paar 1530817 XXXX BRIT V houten 1 paar sars reerde ea CR RR IR DR GRAECI REA CR REDE ICA 1538458 XXXX Db hb rr COE EP CRANE LER EE Ee EL Eee CAG UC Ro d P ERE RE E ra 1522786 XXXX ITER 1522787 XXXX Bedeinde Houten bedeinde ombouw cr rekti RR E PERI be FR hx quee Lk AEN a 1551228 XXXX Verlengde matras ondersteuning Verlengde matras ondersteuning 10 em 1423993 7032 Verlengde matras ondersteuning 20 em 1423994 7032 Algemene EE 1542093 XXXX Transport fitting orit a a a he 1549041 XXXX Handbediening met kantelfunctie HB84 onee eee he 1548934 XXXX Handbediening met kantelfunctie HL84 met ACP functie lle 1548936 XXXX Backup accu emn dccudOOs oo Pc k Rae Rana e REENEN Aki eset a d EUR CR RR en 1449687 XXXX Als een verlenging van de matrasbodem wordt gebruikt kan oo
39. e bed If you have any questions concerning the use or maintenance please contact us All indications of right and left are based on that a person lying on his back in the bed Please note that there may be sections in this user manual which are not relevant to your bed since this manual applies to all on the date of printing existing modules 1 General information I I Product use The Etude Plus bed has been developed for domestic care and features a comfortable sitting and lying position for the patient Furthermore ergonomical operation for the carer is ensured The Etude Plus bed is defined to be used according to Application environment 3 Long term care in a medical area where medical supervision is required and monitoring is provided if necessary and medical electrical equipment used in medical procedures may be provided to help maintain or improve the condition of the patient Application environment 4 Care provided in a domestic area where medical electrical equipment is used to alleviate or compensate for an injury disability or disease ord 145 k If the patient height exceeds 2 meters it is recommended to use a mattress support extension Z N The max patient weight 145 kg provided that the weight of the mattress and the accessories do not exceed 35 kg Safe working load weight max 180 kg FX The bed is not intended for children under 2 years and psychiatric patients LL 180 kg Furthermore Be aware of th
40. e bed ends to their top position 5 Place the motor cable of the foot end on the hook at the foot end 6 Run the backrest to its top position 7 Place the head end motor cables on the 4 hooks at the head end 8 Fasten the safety clip to the control box 2 4 Dismantle the bed e Dismantle siderails and lifting pole Bring the bed to its lowest position and adjust all mattress sup port sections to horizontal position e Disconnect the 230 V supply Roll the cable onto the hook of the head end of the bed e Disconnect all the motor plugs from the motors do not discon nect the backrest motor cable cable 1 Dismantle the safety comb from the control by means of a tool e g a flat headed screwdriver Pull out the cables of the bed end motors and leg section motor Separate the mattress support from the bed ends Divide the head and foot end of the mattress support 3 Operating the bed 3 1 Operating of the hand control unit UP DOWN A y Sitting position Thigh section Height adjustment of the bed Key for locking and unlocking the electrical functions Insert the key below each button to respectively lock and unlock the hand control functions HL 80 with integrated ACP function Vd UP DOWN A y 2 0 Pri HB80 The beds can be equipped with a hand control that activate the tilt of the mattress support this hand control can be ord
41. e entire production process our materials products are quality controlled by the operators Additionally a final test is carried out prior to packaging and shipping The operator carrying out the final test which includes a check of all moveable parts motors and castors issues a QA number on the product thereby confirming its quality If the product does not correspond to the quality demands of Invacare it will be discarded 5 If contrary to our expectations a problem should arise in connection with the delivered product please contact your Invacare supplier An address list is shown on the back side at this manual Invacare reserves the right to alter product specifications without prior notice g P P P 1 3 Labels and symbols A WARNING This symbol warns of dangers If the necessary measurings not are taking it can result in injury or damage to the bed NOTE This symbol inform about important information and guidelines Instruction Reference to the user manual To identify the product please look at the Product label Type no of the bed Serial no e S Date of production 55 einem ETUDE E PLUS Un 200 10050 He C KEN max m To DT wigan E INVACARE EC H NG A S Betergade 3 0K 1270 Hong DENMARK C ie es SC o Symbols See chapter and 7 6 Electrical information See chapter 7 1 4 Safety and Warnings I
42. e limitations of use mentioned in the warnings chapter 1 4 4 estimated product life cycle is 7 years for Etude Plus bed The bed is quipped with loose cables which have to be exchanged if damaged control unit external power supply and motors are protected according to IPx6 When the bed is equipped with a HL80 hand control is protected according to IPx4 Remove the plug from the mains voltage before moving the bed The cable must be kept clear off the floor and the castors during transportation Sound level 45 50 dB A The adjustment area of the mattress support is 40 80 cm or alternatively 33 73 cm angle between the lower leg section and horizontal is adjustable from 0 to 15 1 2 Certification Etude Plus bed is marked with the CE mark in accordance with directive 93 42 EEC concerning Medical Apparatus The Etude Plus bed has been tested and approved according to EN 1970 2000 Beds provided with tilt function can not be approved according to EN 1970 2000 e Mechanically the Etude Plus bed have been approved according to IEC 60601 2 52 e The Etude Plus bed has been approved and marked with the TUN mark The Etude Plus bed has undergone a risk analysis according to EN ISO 14971 2001 03 TUV Invacare is certified according to DS EN ISO 9001 and ISO 13485 which ensures that our customers are always supplied with products of uniform quality Throughout th
43. ectromagnetic propagation is affected by absorption and reflection from structures objects and people 32 8 Technical specifications 8 1 Dimensions All measurements are stated in cm All angles are stated in degrees All measurements and angles are stated without tolerances Invacare reserves the right to change the stated measurements and angles Etude Plus 4 sectioned 85 124 55 56 25 70 18 13 28 33 8 2 Transportation and storage conditions Environment Conditions Relative Atmospheric humidity pressure From 10 C 2095 700 hPa To 50 C 75 1060 hPa Temperature Operating From 5 C 20 700 hPa To 40 75 1060 hPa Be aware that when a bed has been stored under low temperatures it must adjusted to operating conditions before use 34 Invacare Etude Plus USER MANUAL GB GEBRAUCHSANWEISUNG DE GEBRUIKSAANWIJZING NL Inhaltsverzeichnis Allgemeine Informationen 4 I I Verwendung des 4 I2 Zertiizier ngen 4446544 na 5 1 3 Typenschild Aufkleber und Symbole eee 6 1 4 Sicherheit und 7 l5 Garantie 4 ne r MONRO CARROS 9 e Anlieferung des Bettes us veren sn en 10 2 1 Komponenten des Bettes
44. edienungsanleitungen k nnen bei Invacare bestellt oder von der Website heruntergeladen werden 22 6 Reinigung und Wartung e e Service und Wartungsarbeiten am Bett d rfen nur durch entsprechend geschultes Personal durchgef hrt werden Bei normaler t glicher Verwendung ist das Bett alle zwei Jahre einer Routinewartung zu unterziehen 1 e Wird das Bett an einen anderen Verwendungsort verbracht ist das Bett einer au erplanm igen Wartung zu unter ziehen Die in Punkt 6 1 beschriebenen Reinigungshinweise m ssen bei einen Wiedereinsatz des Pflegebettes beachtet wer den 6 Reinigung Das Bett darf nicht in automatischen Waschanlagen oder unter Verwendung eines Hochdruckreinigers gereinigt werden l 2 3 4 Achten Sie darauf vor der Reinigung den Netzstecker aus der Steckdose zu ziehen Das Bett muss mit einem feuchten Schwamm Tuch oder einer feuchten Biirste abgewaschen werden Verwenden Sie ausschlie lich haushalts bliche Reinigungsmittel keinesfalls jedoch S uren Basen oder L sungsmittel wie Aceton oder Nitroverd nnung Die Fernbedienung die Motoren und die Steuerungseinheit k nnen mit B rste und Wasser gereinigt werden keinesfalls jedoch unter Verwendung eines Hochdruckreinigers Trocknen Sie das Bett nach dem Reinigen ab Wichtig Beim Reinigen des Bettes m ssen alle Stecker eingesteckt sein 23 6 2 Wartungplan Wartung und berholung der Etude Plus Betten d rfen nur von entsprechend ges
45. en 1 De stekker zit niet in het stopcontact 2 De zekering in de besturingseenheid is gesprongen 3 De besturingseenheid is defect 1 De stekker van de motor is niet vol ledig in de besturingseenheid gestoken 2 De motor is defect 3 De motorkabel is beschadigd 4 De besturingseenheid is defect 1 De besturingseenheid is defect 2 De handbediening is defect 1 De handbediening is defect 2 De besturingseenheid is defect De motor is beschadigd 27 Mogelijke oorzaak Oplossing 1 Steek de stekker in het stopcontact 2 Vervang de besturingseenheid 3 Vervang de besturingseenheid 1 Steek de motorstekker volledig in de besturingseenheid 2 Vervang de motor 3 Vervang de kabel 4 Vervang de besturingseenheid 1 Vervang de besturingseenheid 2 Vervang de handbediening 1 Vervang de handbediening 2 Vervang de besturingseenheid Vervang de motor 7 2 Elektromagnetische compatibiliteit Richtlijn en verklaring van de fabrikant elektromagnetische straling Het medisch bed ETUDE PLUS is bedoeld voor gebruik in een elektromagnetische omgeving zoals hieronder aangegeven De klant of de gebruiker van het bed moet zeker stellen dat het bed in een dergelijke omgeving wordt gebruikt IEC 61000 3 3 RF emissietest Naleving Elektromagnetische omgeving richtlijn Ri emissis Het verpleegbed ETUDE PLUS gebruikt RF energie uitsluitend voor de CISPR 11 Groep
46. en Sie die Beinsektion dann ab 4 Zubeh rteile Bei Verwendung von Seitengittern ist stets darauf zu achten dass der Abstand zwischen Kopf bzw FuBteil und dem oberen Abschluss des Seitengitters weniger als 6 cm oder mehr als 32 cm betr gt Bei der Montage und Bedienung der Seitengitter besteht Einklemmgefahr f r Finger 4 Montage Demontage der Stahlseitengitter Montage N i Richten Sie sich nach den auf dem Seitengitter angebrachten Anwei Tm H Hi sungen li Fixieren Sie das Seitengitter mit den beiden Knebelschrauben Demontage io WW L sen Sie die beiden Knebelschrauben und nehmen Sie das Stahlsei tengitter ab 1 3 6 cm 2 32 cm gt 4 2 Montage Demontage der Seitengitter Line und Britt V Warnung Um zu verhindern dass sich der Patient einklemmt Erstickungsgefahr oder aus dem Bett f llt m ssen die Gleitschuhe unbedingt ordnungsgem in die Schienen an Kopf und FuBteil eingef hrt werden Justieren Sie die Seitengitterleisten von Hand um deren korrekte Befestigung sicherzustellen Sicherheit Achten Sie darauf dass die B nder zwischen den Seitengitterleisten weder besch digt noch locker sind Montage Montieren Sie ein Ende nach dem anderen Heben Sie die obere Leiste an der Freigabemechanismus muss nach oben auBen weisen A 2 Dr ckenSie d
47. en Verriegelungsstiftam Ende der Seitengitterleiste mit dem Finger ein 3 F hrenSiealle drei Gleitschuhe am Ende der Seitengitterleiste in dieSchie ne am Kopf bzw Fufiteil ein bis die untere Leiste einrastet und das Seitengitter somit nicht mehr aus der Schiene rutschen kann B 4 Wiederholen Sie die Schritte 2 und 3 f r die Montage des anderen Seiten gitterendes Demontage l Senken Sie das Seitengitter ab 2 Demontieren Sie ein Ende nach dem anderen Heben Sie die untere Leiste soweit an dass die Federklinke sichtbar ist 3 Dr ckenSiedieFederklinke mit einem Schliissel oderSchraubendreher ein C 4 Ergreifen Sie die untere Leiste Senken Sie das Seitengitter ab bis keine der drei Leisten mehr in der Schiene am Kopf bzw FuBteil sitzt 5 Wiederholen Sie die Schritte 2 und 4 f r die Demontage des anderen Seitengitterendes 17 4 3 Bedienung der Seitengitter Line und Britt V Kopf und FuBteil k nnen so ausgestattet werden dass die Seitengit ter sowohl auf halber wie auf ganzer H he arretiert werden k nnen In der Normalausf hrung k nnen die Seitengitter nur auf ganzer H he arretiert werden Anheben Aufw rts Ziehen Sie die obere Leiste des Holzseitengitters nach Oben bis die Verriegelungsstifte h rbar einrasten Abw rts Heben Sie die obere Leiste des Holzseitengitters an und dr cken Sie die beiden Verriegelungsringe zusammen Senken Sie das Entriegeln Seitengitter ab Afsenken
48. erantwortung f r jedwede nicht den Informationen und Anweisungen in dieser Bedienungsanleitung entsprechende Nutzung Modifizierung oder Montage des Bettes Die Verwendung von in dieser Bedienungsanleitung nicht aufgef hrten Zubeh rteilen ist nicht zul ssig Das Etude Plus Bett erf llt s mtliche Anforderungen hinsichtlich der Maximalabst nde Es sei jedoch ausdr cklich darauf hingewiesen dass bei Patienten von extrem kleiner Statur die Gefahr besteht dass sie durch die Offnungen in den Seitengittern oder durch den Spalt zwischen dem Seitengitter und der Matratzenaufla ge rutschen Das Bett darf nicht f r Patienten unter 12 Jahren bzw f r Patienten mit einer einer Person unter l2 Jahren entspre chenden Statur verwendet werden In Kombination mit Seitengitter darf das Bett nicht f r Patienten mit einem K rpergewicht unter 45 kg bzw einer K rpergr e unter 150 cm verwendet werden Gleiches gilt f r unruhige Spasmen oder verwirrte Patienten sofern keine die Verwendung zulassende professionelle Risikobeurteilung durchgef hrt wurde Die Seitengitter k nnen mit Sicherheitsbez gen ausgestattet werden Bei Verwendung der Sicherheitsbez ge f r die Seitengitter ist unbedingt auf deren korrekte Anbringung zu achten da andernfalls die Gefahr besteht dass sich der Patient zwischen Liegeflache Seitengitter und Bettende einklemmt wird Erstickungsgefahr Die beweglichen Teile des Bettes stellen eine Einklemmgefahr f r Finger dar
49. ered from Invacare please refer to the section Order numbers for accessories A health Medically trained persons must only operate the tilt function otherwise there is a risk of injury to the patient s 3 2 Operating the braking castors e Set off from the castors might under special conditions appear at different types of absorbing floor covering 1 including untreated or badly treated floors In matters of doubt does Invacare recommended to place suitable kind of protection between the castors and the floor When the bed is positioned correctly at least one castor at the head end and one castor in the foot end must be braked Braking Step on the pedal pos 1 Releasing the brake Step on the release pedal pos 2 Do not release the brake with the fingers as there can be a risk of trapping Each of the castors is provided with brakes for both lengthwise and crosswise locking The brake is foot operated 3 3 Adjustment of leg section Operate the leg section by lifting the mattress handle Up Lift the mattress handle on the leg section Down Lift the mattress handle on the leg section right up and then lower the leg section 4 Accessories When using side rails you must always make sure that the distance between the bed end and the side rail s handle upper edge is less than 6 cm or more than 32 cm There is risk of entrapment of fingers on assembly and operation of the side rail
50. ess support extension 19 406 Mattresses sada wanna u 20 4 7 Transport brackets oves rw a ONE 21 Order numbers for accessories 22 Cleaning and Maintenance 23 6 1 Cleaning A ERRORS wane EAR RR RR e i El n eke e 23 6 2 Maintenance chart 30 040 00000 l sx a ae a a kk al a eyek l dal ee ala elen 24 6 3 Maintenance russ anni 25 6 4 Lubrication 25 Electrical system cs 000 24 NEEN la l l ek E NEEN 26 7 1 Trouble shooting the electrical system 27 7 2 Electo Magnetic Compliance EMC 28 Technical 5 33 8 1 Dimensions s salek EE a o eee ROCCO 33 8 2 Transportation and storage conditions 34 8 3 Weenen ek OR IRAE a n r ew 35 Waste 15 che soe Heeb he QE ee ee e e e e e e e e e e e e ee e e ee ee eee eee e 35 Congratulations Congratulations on your choice of Invacare Etude Plus nursing bed Etude Plus is the dismantle able nursing bed from Invacare designed especially for home nursing Etude Plus bed provides ease of handling combined with good functionality Please read the entire user manual before using th
51. f rmig damit die Vorrichtungen ber die gesamte Lebensdauer des Betts fest sitzen Stellen Sie sicher dass Kopf und Fu teil auf gleicher H he sind Das Bett kann in der oberen A wie in der unteren Position B nivelliert werden Drehen Sie den Verriegelungsring am Kopf und am FuBteil in die verriegelte Stellung Die Verriegelungsringe sorgen daf r dass sich die Liegeflache nicht unbeabsichtigterweise vom Kopf oder Fu teil l st Steuerungseinheit Die Steuerungseinheit wird am R ckenlehnenmotor eingerastet Die Steuerungseinheit tr gt einen Aufkleber mit Symbolen die den Anschluss der Motorkabelstecker illustrieren e R ckenlehnenmotor Bein Oberschenkelsektionsmotor FuBendemotor e Handbedienteil 2 3 Verkabelung Um zu verhindern dass die Kabel bei Aktivierung der Motoren gedehnt werden und rei en m ssen die nachstehenden Anweisungen genauestens befolgt werden Schlie en Sie die Kabel des Kopf und des Fu endemotors direkt an die Steuerungseinheit an Der Stecker des Oberschenkelsektionsmotors muss durch die Off nung des Tr gers f r den R ckenlehnenmotor gef hrt und dann an die Steuerungseinheit angeschlossen werden Stecken Sie das Netzkabel in eine 230 V Steckdose ein Fahren Sie die Motoren an Kopf und Fufiteil in die oberste Position H ngen Sie das Kabel des FuBteilmotors in den Haken am FuBteil ein Fahren Sie die R ckenlehne in die oberste Position H ngen Sie das
52. hreitet die gemessene Feldstarke am Aufstellungsort des Pflegebettes ETUDE PLUS die entsprechende Konformit tsstufe s o muss der st rungsfreie Betrieb des Pflegebettes ETUDE PLUS berwacht werden Wird dabei festgestellt dass das Pflegebett ETUDE PLUS nicht ordnungsgem funktioniert m ssen entsprechende MaBnahmen z B Anderung der Ausrichtung oder Position des Pflegebettes ETUDE PLUS ergriffen werden Im gesamten Frequenzbereich von 150 kHz bis 80 MHz m ssen die Feldst rken unter V V m liegen 3l Empfohlener Mindestabstand zwischen tragbaren und mobilen HF Kommunikationsgeraten und dem Pflegebettes ETUDE PLUS Das Pflegebett ETUDE PLUS ist f r die Nutzung in einem Umfeld vorgesehen in dem die St rungen durch ausgestrahlte HF St r gr en kontrolliert werden k nnen Durch Einhaltung eines Mindestabstands zwischen dem Pflegebett ETUDE PLUS und tragba ren und mobilen HF Kommunikationsger ten Sendern k nnen elektromagnetische Beeinflussungen verhindert werden Dieser Mindestabstand bestimmt sich wie im Folgenden angegeben nach der maximalen Ausgangsleistung und dem Frequenzbereich des Kommunikationsger ts Maximale Nennausgangsleistung des Senders Mindestabstand m in Abh ngigkeit von der Frequenz und maximalen Nennausgangsleistung des Senders 150 kHz bis 80 MHz 80 MHz bis 800 MHz 800 MHz bis 2 5 GHz w d WP gel WP asp p Vi Ei Ei 0 01 0 12 0 12 0 23 0 1 0
53. ie Bestimmungen Emissionen werden eingehalten IEC 61000 3 3 28 Anleitung und Herstellererkl rung elektromagnetische Immunitat Das Pflegebett ETUDE PLUS ist zur Verwendung in der nachfolgend definierten elektromagnetischen Umgebung vorgesehen Der Kaufer oder Anwender des Bettes muss sicherstellen dass es in einer solchen Umgebung verwendet wird Immunit tstest IEC 60601 Testniveau Einhaltungsniveau Elektromagnetische Umgebung Anleitung Elektrostatische Entladung ESD IEC 61000 4 2 6 kV Kontakt 8 kV Luft 6 kV Kontakt 8 kV Luft Der FuBboden muss aus Holz Beton oder Keramik fliesen bestehen Ist der Boden mit synthetischem Material bedeckt muss die relative Luftfeuchtigkeit mindestens 30 76 betragen Elektrostatische Transienten 2 kV Stromver sorgungsleitungen 2 kV Stromver sorgungsleitungen Die Netzstromqualitat muss der einer typischen 2 kV Gleichtaktmodus 2 kV Gleichtaktmodus Burst i lA EE kV Ein Ausgangs gewerblichen oder Krankenhausumgebung entsprechen IEC 61000 4 4 leitungen leitungen kV Differenzial kV Differenzial P 5 modus modus Die Netzstromqualitat muss der einer typischen IEC 61000 4 5 gewerblichen oder Krankenhausumgebung entsprechen Spannungsabf lle kurze Unter brechungen und Spannung schwankungen in den Stromver sorgungsleitun gen IEC 61000 4 1 lt 5 U gt 95
54. interne functies Daardoor zijn de RF emissies zeer laag en veroorzaken deze hoogstwaarschijnlijk geen interferentie in nabije apparaten deels EE Het verpleegbed ETUDE PLUS is geschikt voor gebruik in alle situaties inclusief Klasse B thuissituaties en overal waar het openbare laagspanningsnet de stroom levert voor CISPR 11 huiselijke doeleinden partly Harmonische emissies Klasse A IEC 61000 3 2 Spanningsvariaties flikkeremissies Voldoet 28 Richtlijn en verklaring van de fabrikant elektromagnetische immuniteit Het medisch bed ETUDE PLUS is bedoeld voor gebruik in een elektromagnetische omgeving zoals hieronder aangegeven De klant of de gebruiker van het bed moet zeker stellen dat het bed in een dergelijke omgeving wordt gebruikt Immuniteitstest IEC 60601 testniveau Niveau van overeenkomst Elektromagnetische omgeving richtlijn Elektrostatische 6 kV contact t 6 kV contact Vloeren moeten van hout beton of tegels zijn Als transient burst IEC 61000 4 4 stroomtoevoerkabels kV voor input outputkabels supply lines kV for input output lines SESCH vloeren zijn bekleed met synthetische vloerbedekking IEC 61000 4 2 8 kV lucht 8 kV lucht moet de relatieve vochtigheid minstens 3076 zijn Elektrostatische 2 kV voor 2 kV for power De kwaliteit van de netstroom moet overeenkomen met die van een commerci le of ziekenhuisomgeving Overspanning
55. k De bevestigingshandvaten aan de bed uitein den mogen zich in eerste instantie niet onder in bedrailsleuven bevinden De sleuven zijn wigvormig zodat deze goed op het frame van het bed passen 10 Zorg ervoor dat de bed uiteinden dezelfde stand hebben Het bed kan in de hoge stand A of de lage stand B staan Il Draai de vergrendelring naar de vergrendelde positie ons C ds t9 NM De vergrendelringen zorgen ervoor dat de matrasbodem niet per ongeluk los raakt van de bed uiteinden Besturing De besturing is aan de motor van de rugleuning bevestigd Het label op de besturing bevat symbolen die aangeven waar de stek kers van de motoren moeten worden aangesloten Motor van rugleuning Motor van been dijgedeelte e Motor van bed uiteinde Handbediening 2 3 Kabels Om te voorkomen dat de kabels uit elkaar worden getrokken wan neer de motoren worden geactiveerd is het van het grootste belang dat u de onderstaande instructies opvolgt Sluit de kabels van de motoren van de bed uiteinden hoofd en voe teneind rechtstreeks aan op de besturing 2 Destekker van de dijmotor moet door de opening van de ondersteu ning voor de motor van de rugleuning worden geleid en vervol gens worden aangesloten op de besturing Sluit de voedingskabel aan op de 230 V stekker Beweeg de motoren van de bed uiteinden naar hun hoogste stand 5 Bevestig de motorkabel van het voeteneinde aan de haak aan het voete
56. k een verlengd zijhek worden gebruikt XX XXXX betekent dat de kleur houtsoort moet worden opgegeven Neem voor meer informatie contact op met het verkoopbedrijf Gebruik alleen originele reserveonderdelen Lijsten met reserveonderdelen en extra gebruikershandleidingen kunnen worden besteld via Invacare of onze website 22 6 Schoonmaken en onderhoud e Service en onderhoud aan het bed mag alleen worden uitgevoerd door mensen die hiertoe de juiste instructies of training hebben gekregen 1 Bij een normaal dagelijks gebruik moet de eerste 2 jaar en vervolgens elk tweede jaar service worden uitgevoerd volgens het serviceschema e Wanneer de locatie van het bed wordt gewijzigd moet service worden uitgevoerd volgens het serviceschema 6 1 Schoonmaken Het bed mag niet worden schoongemaakt in geautomatiseerde wasinrichtingen of met hogedrukreinigers altijd de stekker uit het stopcontact voordat het bed wordt schoongemaakt Het bed moet worden gereinigd met een natte spons doek of borstel 3 Gebruik hiervoor een normaal schoonmaakmiddel voor huishoudelijk gebruik Gebruik nooit middelen die zuren basen of oplos middelen bevatten zoals aceton of thinner 4 De handbediening motoren en besturingseenheid mogen wel met een borstel en water worden schoongemaakt maar niet met een drukreiniger 5 Maak het bed het schoonmaken goed droog LET OP Alle andere stekkers moeten tijdens het schoonmaken v
57. l is visible 3 Press the spring pawl with a key or a screwdriver C 4 Hold the lower bar Lower the side rail until all three bars are free of the bed end rail 5 Repeat points 2 to 4 when dismounting the other end of the side rail 17 4 3 Operation Line and Britt side rail The bed end may be equipped to lock the siderail at half height as well as in the top position Normally the side rail can only be Rai locked in top position Up Pull up the top wooden side rail bar until the locking pin locks with an audible click Down Lift the top wooden side rail bar and press the two locking rings together Lower the side rail Release Lower 4 4 Lifting pole Position the lifting pole in such way that the handle extends inwards across the bed If the lifting pole is used while the handle has been turned away from the bed the bed can tip when the handle is used Mounting 1 Remove the plug from the lifting pole tube at the head end of the bed where the lifting pole is to be placed 2 Insert the lifting pole into the lifting pole tube and fix with the thumb screw Adjusting the height of the lifting pole handle l Loosen the cord as shown in A 2 Thelifting handle can now be adjusted to the desired height 3 Press the cord together as shown in B and check that the cord is locked in the cord lock by pulling the handle The distance between the lifting pole and the mattress Minimum at 16 cm
58. lagen is geweest moet het eerst op bedrijfstemperatuur komen voordat het in gebruik wordt genomen 34 8 3 Weights Etude Plus bed end with extra plate piece 20 6 kg Etude Plus bed end without extra plate 179 kg Mattress support standard head 24 1 kg Mattress support w autoregression head 27 9 kg Mattress support w autoregression head end without acuator and control box 24 1 kg Mattress support ht ned dat ine 17 4 kg Scala Basic 2 side rail piece eneen eeen 74 kg Lifting polek eria 4 2 kg Mattress support extension 10 3 2 kg Mattress support extension 20 cm 5 5 kg Etude Plus standard bed complete excluding accessories 77 3 kg Etude Plus auto regression complete excluding 82 7 kg 9 Waste disposal This product has been supplied from an environmentally aware manufacturer that complies with the Waste Electrical and Electronic Equipment WEEE Directive 2002 96 CE This product may contain substances that could be harmful to the environment if disposed of in places landfills that are not appropriate according to legislation The crossed out wheelie bin symbol is placed on this prod
59. lass A IEC 61000 3 2 Voltage fluctuations flicker emissions IEC 61000 3 3 28 Guidance and manufacturer s declaration electromagnetic immunity The medical bed ETUDE PLUS is intended for use in the electromagnetic environment specified below The customer or the user of the bed should assure that it is used in such an environment Immunity test IEC 60601 test level Compliance level Electromagnetic environment guidance Electrostatic discharge ESD IEC 61000 4 2 6 kV contact 8 kV air 6 kV contact 8 kV air Floors should be wood concrete or ceramic tile If floors are covered with synthetic material the relative humidity should be at least 30 Electrostatic transient burst 2 kV for power supply lines kV for input output 2 kV for power supply lines kV for input output Mains power quality should be that of a typical commercial or hospital environment input lines IEC 61000 4 11 30 dip in U for 25 cycles lt 5 U gt 95 dip in U for 5 sec 30 dip in U for 25 cycles lt 5 U gt 95 dip in U for 5 sec IEC 61000 4 4 lines lines E n FI Surge iid differential Mains power quality should be that of a typical IEC 61000 4 5 2 kV common mode 2 kV common mode EE EE lt 5 U lt 5 U gt 95 dip in U gt 95 dip in U for 0 5
60. ld strengths should be less than V V m 3l Recommended separation distances between portable and mobile RF communications equipment and the medical bed ETUDE PLUS The medical bed ETUDE PLUS is intended for use in an electromagnetic environment in which radiated RF disturbances are controlled The customer or the user of the medical bed ETUDE PLUS can help prevent electromagnetic interference by maintaining a minimum distance between portable and mobile RF communications equipment transmitters and the medical bed ETUDE PLUS as recommended below according to the maximum output power of the communications equipment Rated maximum output Separation distance according to frequency of transmitter m 150 kHz to 80 MHz 80 MHz to 800 MHz 800 MHz to 2 5 GHz of transmitter der E def d LLWP Vi Ei Ei 0 01 0 12 0 12 0 23 0 1 0 37 0 37 0 74 1 17 1 17 2 33 10 3 69 3 69 7 38 100 11 67 11 67 23 33 For transmitters rated a maximum output power not listed above the recommended separation distance d in metres m can be estimated using the equation applicable to the frequency of the transmitter where P is the maximum output power rating of the transmitter in watts W according to the transmitter manufacturer NOTE I At 80 MHz and 800 MHz the separation distance for the higher frequency range applies NOTE 2 These guidelines may not apply in all situations El
61. leiden tot letsel of tot schade aan het bed OPMERKING dit symbool wijst op belangrijke informatie en richtlijnen e Instructie dit is verwijzing naar de gebruikershandleiding INVACARE EC HONG A S Betergade 3 0K 1270 Hong DENMARK C Ty penis yan An PLUS Um 230 4 en erienr ail DEN max mm it jll Code 145kg D it GL Ze QE e Productiedatum Symbolen Zie hoofdstuk en 7 6 1 4 Veiligheid en Waarschuwingen Invacare accepteert geen enkele aansprakelijkheid voor schade die het gevolg is van een gebruik wijziging of mon tage van het product dat die afwijkt van wat in deze gebruikershandleiding is beschreven Accessoires die niet in deze handleiding worden vermeld mogen niet worden gebruikt Het Etude Plus bed voldoet aan alle vereisten met betrekking tot maximale afstanden Als het bed echter wordt gebruikt voor de verzorging van pati nten met kleine lichaamsafmetingen dient u er reke ning mee te houden dat het risico bestaat dat een dergelijke pati nt tussen de openingen in de zijhekken of tussen de matrasbodem en de zijhekken door kan glijden Het bed mag niet worden gebruikt door pati nten die jonger zijn dan 2 jaar of door pati nten met lichaamsafmetin gen die overeenkomen met die van een twaalfjarige of jonger Het bed mag niet in combinatie met de zijhekken worden gebruikt voor personen die minder d
62. m in high position Britt V side rail Mattress support 22 cm TEN 88 5 90 cm 200 cm platform in low position Britt V side rail Mattress support 15 cm 5 cm 88 5 90 cm 200 cm platform in high position 4 7 Transport brackets See instructions at the last page in this User manual 21 5 Order numbers for accessories Side rail Scala Baic 2 foldable eg eener aa en s pu aec al gah area th De ale gc od al s 1528930 XXXX Scala Basic Plus 2 foldable pair llle III 1529745 XXXX Scala Medium 2 foldable Bal bee n k yA aw Or n AER eh ie 1530436 XXXX Scala Decubi 2 foldable pair 1530817 XXXX Britt V wooden I pair us eee e Ee een 1538458 XXXX Lie vezes EU OP ESSE AEE eU ERE OP EE RE Tr 1522786 XXXX lne extendable 2 o doce rrr ae ee 1522787 XXXX Bed end extra plate Bed end plates nu Bean AER ee ERE ker RE E 1551228 XXXX Mattress support Mattress support extension sen nonnen ERR ep ROO ea an VC ate 1423993 7032 Mattress support extension 20 em 1423994 7032 General Bic 1542093 XXXX Transport fitting ioci er re W0 ee See ena d r dra RP PE Sindee a eee fea a 1549041 XXXX Hand control with tilt HB8 siete us hi trn eR x aes p ad Epi dE Seine MEE Pu 1548934 XXXX Hand control with tilt HL84 with integrated ACP function oaeen 1548936 XXXX Backup battery arid battery x e
63. neinde Beweeg de rugleuning naar de hoogste stand 7 Bevestig de motorkabels van het hoofdeinde aan de vier haken aan het hoofdeinde 8 Bevestig de veiligheidsclip aan de besturing rw EN 2 4 Demontage van het bed N Verwijder de zijhekken en de optrekstang Zet het bed in de laagste stand en zet alle gedeelten van de matrasbo dem in de horizontale stand Koppel de 230 V voeding los Rol de kabel op aan de haak aan het hoofdeinde van het bed Koppel alle motorstekkers los van de motoren koppel de motorka bel van de rugleuning kabel niet los Verwijder de veiligheidsclip van de besturing bijvoorbeeld met een schroevendraaier Verwijder de kabels van de motoren van de bed uiteinden en het beengedeelte Verwijder de matrasbodem van de bed uiteinden Trek het hoofd en voeteneinde van de matrasbodem uit elkaar 3 Bediening van het bed 3 1 De handbediening OMHOOG OMLAAG OMHOOG OMLAAG A y A y w M At lt Zittende positie N EER Knieverstelling lt Hoogte verstelling van het bed af Veligheidsslot voor het blokeeren van de handbediening Gebruik sleutel onder de knop om de lt ACP box op blokkeren te zetten Pri HL 80 met geintegreerde ACP functie HB 80 Het bed kan worden voorzien van een handbediening voor het kantelen van de matrasbodem Deze handbediening kan bij Invacare worden besteld 3 2 De
64. noer van het medische elektrisch apparaat moet worden vrijgehouden van de hulpstukken of andere beweg ende delen van het bed Zorg ervoor dat er zich onder boven of in de buurt van het bed geen voorwerpen of obstakels bevinden die de ver plaatsing van het bed of de matrasbodem kunnen belemmeren zoals meubels raamkozijnen en opbergdozen Zet het bed altijd in de laagste stand voordat de pati nt zonder toezicht in het bed achterlaat Het kan gevaarlijk zijn om over de voedingskabel heen te rollen e e Zorg ervoor dat de voedingskabel niet tussen bewegende delen terecht komt 1 e Haal de netstekker uit het stopcontact voordat u het bed verplaatst De kabels moeten zo worden bevestigd dat ze de vloer niet raken en de zwenkwielen niet blokkeren Hang de voedingskabel bij voorkeur op aan de daarvoor bestemde haak zoals in de illustratie 1 5 Garantie De garantie dekt alle materiaal en productiedefecten gedurende 2 vanaf leverdatum mits kan worden aangetoond dat die defecten al v r de levering bestonden Alle fabricagefouten of defecten moeten onmiddellijk worden gemeld Invacare kan het defect repareren of het onderdeel vervangen Aanvullende kosten zoals kosten voor transport verpakking arbeid en dergelijke vallen niet onder de garantie van Invacare en komen voor rekening van de klant Het volgende valt niet onder de garantie Schade die tijdens het transport is ontstaan en die niet meteen aan de expediteur
65. nvacare accepts no liability for any use change or assembly of the product other than as stated in this user manual Accessories not mentioned in this manual must not be used The Etude Plus bed fulfils all requirements regarding maximum distances However if the bed is used for the care of patients with a small body dimensions it must be especially noted that there is a risk of such a patient slipping through the openings between the side rails or through the opening between the side rail and the mattress support The bed must not be used by patients under 2 years of age or by patients with body size equivalent to an average 12 years old or smaller The bed in combination with side rails must not be used for persons under 45 kg or under 150 cm height Either for persons that are restless spasms or confused unless a professional risk assessment has taken place and been accepted A correctly installed safety cover on the side rails can be used When using side rails and the according safety cover it is essential to ensure correct fitting otherwise there is danger of entrapment suffocation between mattress support side rail and bed end There is a risk of entrapment of fingers in the bed moving parts Electromagnetic interference between the bed and other electrical products can occur To reduce or eliminate such electromagnetic interference increase the distance between the bed and the products or switch them of This medical
66. ommunicatieapparatuur mag niet dichter bij enig onderdeel van het medisch bed ETUDE PLUS worden gebruikt inclusief snoeren dan de aanbevolen afstand zoals berekend met de vergelijking die van toepassing is op de zenderfrequentie Aanbevolen onderlinge afstand Geleidings RF 3V 3V 35 d 7_WP IEC 61000 4 6 Vi 35 p 80 MHz en 800 MH d WP zen 2 Stralings RF 3 V m 3 V m IEC 61000 4 3 d WP 800 MHz en 2 5 GHz 1 30 Niveau van N s Immuniteitstest IEC 60601 testniveau Elektromagnetische omgeving richtlijn overeenkomst waarin p het maximale uitgangsvermogen van de zender is in watts W volgens de specificatie van de zenderfabrikant en d de aanbevolen onderlinge afstand in meters m De veldsterkte van vaste RF zenders zoals die is bepaald bij een onderzoek van de elektromagnetische omgeving moet kleiner zijn dan het toegestane niveau binnen elk frequentiegebied Interferentie kan optreden in de nabijheid van apparatuur met het volgende symbool A OPMERKING 1 bij 80 MHz en 800 MHz zijn de daarboven gelegen frequentiegebieden van toepassing OPMERKING 2 deze richtlijnen zijn mogelijk niet in alle omstandigheden van toepassing Elektromagnetische straling wordt beinvloed door absorptie en reflectie van structuren objecten en mensen Veldsterktes van vaste zenders zoals basisstations voor draadloze telefonie mobilofoons amateurzenders AM en FM radiozende
67. rden wir m chten Sie in diesem Fall auf den Abschnitt Bestellnummern f r Zubeh rteile verweisen besteht die Gef hrdung der Gesundheit des Patienten In Deutschland ist diese Schragstellungsfunktion Tilt in der h uslichen Pflege generell verboten 1 Die Schr gstellungsfunktion Tilt darf nur von medizinisch geschulten Personen ausgef hrt werden ansonsten 3 2 Bedienung der Laufrollenbremsen Die Laufrollen k nnen m glicherweise Spuren auf dem Fu boden hinterlassen insbesondere bei nicht oder unzu e reichend behandelten Fu b den Im Zweifelsfall empfiehlt es sich zum Schutz des FuBbodens Unterlagen zwischen 1 Laufrollen und FuBboden zu legen Nach korrekter Aufstellung des Bettes muss die Bremse mindestens je einer Laufrolle am Kopf und am Fu ende des Bettes aktiviert werden 1 Aktivieren der Bremse durch Fu bet tigung des Pedals l 2 L senderBremsedurchFufbet tigungdes Freigabemechanismus Versuchen Sie keinesfalls den Freigabemechanismus der Bremse von Hand zu bet tigen Einklemmgefahr Alle Laufrollen sind mit Bremsen ausgestattet die jede Bewegung in Langs und Querrichtung blockieren Die Bremsen sind f r die Fu bet tigung vorgesehen 3 3 Anpassung der Beinsektion Die Anpassung der Beinsektion erfolgt durch Anheben des Matrat zengriffs Aufw rts Heben Sie den Matratzengriff der Beinsektion an Abw rts Heben Sie den Matratzengriff der Beinsektion bis ganz nach oben an und senk
68. ria GmbH Herzog Odilostrasse 101 A 5310 Mondsee Tel 43 6232 5535 0 Fax 43 6232 5535 4 info austria invacare com www invacare at Switzerland Invacare AG Benkenstrasse 260 CH 4108 Witterswil Tel 41 0 61 487 70 80 Fax 41 0 61 487 70 81 switzerland invacare com www invacare ch United Kingdom Invacare Limited Pencoed Technology Park Pencoed Bridgend CF35 5AQ Tel 44 0 1656 776222 Fax 44 0 1656 776220 UK invacare com www invacare co uk Manufacturer Invacare Lda Rua Estrada Velha 949 P 4465 784 Leca do Balio www invacare pt Yes you can
69. rs en tv zenders kunnen niet nauwkeurig theoretisch worden voorspeld Om de invloed van vaste RF zenders op de elektromagnetische omgeving te bepalen moet een elektromagnetisch veldonderzoek worden overwogen Indien de gemeten veldsterkte op de locatie waar het medisch bed ETUDE PLUS wordt gebruikt de eerder genoemde toegestane RF waarden overstijgt moet het medisch bed worden geobserveerd om het normaal functioneren vast te stellen Als abnormaal functioneren wordt geconstateerd zijn wellicht extra maatregelen nodig zoals het verdraaien of verplaatsen van het medisch bed Binnen het frequentiegebied van 150 kHz tot 80 MHz moet de veldsterkte lager zijn dan V m 3l Aanbevolen minimumafstanden tussen draagbare mobiele RF communicatieapparatuur en het medisch bed ETUDE PLUS Het medisch bed ETUDE PLUS is bedoeld voor gebruik in een elektromagnetische omgeving waarin RF stralingsstoringen onder controle zijn De klant of de gebruiker van het medisch bed ETUDE PLUS kan elektromagnetische interferentie helpen voorkomen door een minimumafstand te bewaren tussen draagbare mobiele RF communicatieapparatuur zenders en het medisch bed zoals hieronder aanbevolen het maximale uitgangsvermogen van de communicatieapparatuur in aanmerking genomen Onderlinge afstand overeenkomend met zenderfrequentie Opgegeven m maximumuitvoer van 150 kHz en 80 MHz 80 MHz en 800 MHz 800 MHz en 2 5 GHz de zender w d
70. s must only be performed by personnel who have received the neces sary instruction or training Bed Id no Visual inspection of all parts of the bed plastic deformation and or wear and tear of welded joints Control of all centres of rotation motors mattress support parts All motors running without failures with regular speed and at low noise Check the Rastofix fittings and function HEE DE EE EE EE Visual inspection of all cabinets for damages TT Check that mains cable and plug are intact Check the running of the cable Check all remaining cables for damages Also check the running of the cables Check of siderails fixing and locking movement o Check the wheels security braking and free rolling o ld 24 6 3 Maintenance Before use Ensure that all manual and electrical parts functions correctly and are in a secure state After 3 months Ensure that all manual and electrical parts are functioning and tighten bolts screws nuts etc Every two year Service should be performed after the maintenance chart See chapter 6 2 Maintenance chart 6 4 Lubrication plan We recommend lubricating the bed according to the following instructions l Points of rotation in mattress support and base frame lubricate with oil 2 All of the motors tension rod lubricate with oil L Niyaz 3 All motor bearings and Rastofix fitting lubricate with oil On Lubricate
71. stand HF St rgr en 3V 3V 3 5 IEC 61000 4 6 d 7WP Vi Ausgestrahlte 3 5 j HF St rgr Ben d WP 80 MHz bis 800 MHz 3 V m 3 V m IEC 61000 4 3 d WP 800 MHz bis 2 5 GHz 1 30 Immunitatstest IEC 60601 Testniveau Einhaltungsniveau Elektromagnetische Umgebung Anleitung hierbei bezeichnet p die maximale Ausgabeleistung des Senders in Watt W gem Herstellerangaben und d empfohlenen Mindestabstand in Metern m Die von ortsfesten Sendern hervorgerufenen Feldst rken bestimmt durch eine elektromagnetische Standortaufnahme m ssen in allen Frequenzbereichen unter den Einstufungswerten liegen In der N he von Ger ten die mit folgendem Symbol gekennzeichnet sind kann es zu St rungen kommen 2 HINWEIS Bei 80 MHz und 800 MHz gilt der jeweils h here Frequenzbereich HINWEIS 2 Diese Richtlinien werden m glicherweise nicht allen Situationen gerecht Die Ausbreitung elektromagnetischer Felder wird durch Absorption und Reflektion durch Bauten Objekte und Personen beeinflusst Die Feldst rken von ortsfesten Sendern z B Basisstationen f r Handys schnurlose Telefone oder Ger te des mobilen Landfunks Amateurfunk Mittelwellen UKW und Fernsehsender k nnen auf theoretischem Wege nicht mit der erforderlichen Genauigkeit bestimmt werden F r die Beurteilung der elektromagnetischen Umgebung von ortsfesten HF Sendern muss eine Standortaufnahme durchgef hrt werden bersc
72. tly reported Invacare may repair the fault or replace the component The warranty provided by Invacare does not cover additional costs transport packaging labour sundry expenses etc are for the customer s account The warranty does not cover Damage caused during transport that is not directly reported to the forwarder at the moment of delivery Repairs performed by unauthorized centers and personnel Parts subject to normal wear Malicious damage or damaged caused by improper use of the bed 2 Receiving the bed 2 1 Parts of the bed e 1 Check the packaging if the bed shows any signs of damage upon delivery please se the terms of delivery Follow part must be provided Mattress support head end 2 pcs of mattress support bracket Pair of side rails wood or steel Mattress support foot end Motor for bed end Castors Motor for head end Mattress support extension 10 or 20 cm Optional Motor for leg end 0 Pair of bed ends Hand control HB80 or HL80 SN 0049 Ur WINE Optional Lifting pole Transport fitting 2 2 Assembly of the bed Mattress Support Place the two inserts in the head end of the mattress support The inserts must be mounted in such a way that one extends further out of the side tube than the other Loosely screw in the two thumb screws Push the foot end of the mattress support onto the two inserts Tighten with two thumb screws Retighten the two thumb screws
73. tt bei Anlie 1 ferung irgendwelche Zeichen einer Besch digung aufweisen sollte Lieferumfang Liegeflache Kopfende Matratzenhalter 2 St ck Seitengitter 1 Paar Holz oder Stahl Liegeflache FuBende Motor fiir Kopf und FuBende Bremsrollen Motor f r R ckenlehne Liegeflachenverlangerung 10 oder 20 cm optional Motor f r Beinsektion 0 Kopf und Fufiteil Handbedienteil HB80 oder HL80 0 0 INR WN Optional Aufrichter Transportsicherung 2 2 Montage des 5 Liegeflache Setzen Sie die beiden Einschubrohre in das Kopfende der Lie geflache ein Die Einschubrohre m ssen so angebracht werden dass der eine weiter aus dem seitlichen Rohr herausragt als der andere Schrauben Sie die beiden Knaufschrauben lose ein Schieben Sie das Fu ende der Liegefl che auf die beiden Eins tze auf Ziehen Sie die beiden Knaufschrauben an Ziehen Sie die beiden Knaufschrauben am Kopfende des Oberge stells wieder an Stellen Sie die beiden Matratzengriffe an der R ckenlehne auf recht Stellen Sie den Griff der Beinsektion aufrecht Drehen Sie den Verriegelungsring am Kopf und am FuBteil in die entriegelte Stellung Lassen Sie die Liegeflache am Kopf und am Fufiteil einrasten und dr cken Sie sie fest in Position Die Haltevorrichtungen an den Bettenenden werden anf nglich m glicherweise nicht vollst ndig bis zur Unterseite der L cher f r die Bettengitter durchgef hrt Die L cher sind keil
74. uct to encourage you to recycle wherever possible Please be environmentally responsible and recycle this product through your recycling facility at its end of life All wooden parts must be dismantled and sent for incineration All electric parts must be dismantled and be disposed of as electric components Plastic parts must be sent for incineration or recycling Steel parts and castors must be disposed of as waste metals Waste disposal must comply with the laws and regulations pertaining waste handling in each country Customer Sales and Service Belgium amp Luxemburg Invacare nv Autobaan 22 B 8210 Loppem Tel 32 0 50 83 10 10 Fax 32 0 50 83 10 11 belgium invacare com www invacare be Deutschland Invacare GmbH AlemannenstraBe 10 D 88316 Isny Tel 49 0 75 62 7 00 0 Fax 49 0 75 62 7 00 66 kontakt invacare com www invacare de Eastern Europe Invacare KleiststraBe 49 D 32457 Porta Westfalica Tel 49 0 57 31 754 540 Fax 49 0 57 31 754 541 edo invacare com www invacare eu com Ireland Invacare Ireland Ltd Unit 5 Seatown Business Campus Seatown Road Swords County Dublin Ireland Tel 353 810 7084 Fax 353 1 810 7085 ireland invacare com www invacare ie Nederland Invacare BV Celsiusstraat 46 NL 6716 BZ Ede Tel 31 0 318 695 757 Fax 31 0 318 695 758 nederland invacare com www invacare nl csede invacare com 1551227 04 2012 05 25 sterreich Invacare Aust
75. uk smeren met olie Smeren met medisch schone olie zoals KEN WO 50 bestelnr no 813239 LET OP Het glijsysteem van de houten zijhekken mag niet met olie worden gesmeerd omdat de houten stangen dan niet meer goed bewegen Haal altijd de netstekker uit het stopcontact voordat u het bed schoonmaakt 25 7 Technische Specificaties Voedingsspanning Max ingangsstroom Uitgangsspanning Intervalspanning periodieke werking van motor Veiligheidsklasse Isolatieklasse Dubbel geisoleerd Wisselstroom Gelijkstroom De pati nt is niet afgeschermd van de massa en het chassis Potentiaalvereffening 230 V 10 50 Hz 24 max 70 VA 10 max 6 min h IPX6 Il type B Het bed is niet voorzien van een netschakelaar dus het netsnoer vormt de enige verbinding met het voedingsnet 26 7 Het opsporen van fouten in het elektrische systeem Het stroomlampje brandt niet Het stroomlampje brandt wel maar de motor loopt niet Het relais in de besturingseenheid maakt een klikkend geluid Het stroomlampje brandt wel maar de motor loopt niet Er is geen relaisgeluid te horen in de besturingseenheid De besturingseenheid is in orde met uitzondering van n richting op n kanaal De motor loopt maar de as beweegt niet De motor kan niet de volledige last tillen De motor maakt geluid maar de zuigerstang beweegt niet De zuigerstang beweegt wel naar binnen maar niet naar buit
76. um 2 klappbar Paar s E Ere a Se n Ro ee aen 1530436 XXXX Scala Decubi klappbar Paar Ayak ee Ree RR oe ORE IE E Rud a REPE dn 1530817 XXXX Holzseitengitter BRITT V 1 Paar eene eee eee eee eee eee 1538458 XXXX Eine s see eae eee Ae DS eee ChE SG REE E Bee FR ELI Y AEE d ERE OP REV RR T E 1522786 XXXX Eine VEMIAM SOE M MERC Tr T 1522787 XXXX Bettenden Holzabdeckung f r Bettende saniert reiii e e RE er 1551228 XXXX Liegeflachenverlangerung Liegeflachenverlangertng eis vu bb oce es epo RE banged pee xa ate 1423993 7032 Liegefl chenverl ngerung 20 cm oee eee eee eee eee eee eee een 1423994 7032 General Willa zz anh dede EE EEN 1542093 XXXX REG a a hen rs 1549041 Handbedienteil mit Schr gstellungsfunktion HB84 Tilt 1548934 XXXX Handbedienteil mit Schr gstellungsfunktion HL84 Tilt mit integrierter ACP 1548936 XXXX Sicherheitsbatterie und Batteriebox 0 0 eee eee ala l0 k lk kane d hen 1449687 XXXX Bei Verwendung einer Liegeflachenverlangerung kann auch ein verlangertes Seitengitter verwendet werden und XXXX in der Bestellnummer stehen f r die Farbe bzw Holzart N here Informationen erhalten Sie von Ihrem Lieferanten Bitte verwenden Sie ausschlieBlich Originalersatzteile Ersatzteillisten und zus tzliche B
77. wijderen 17 4 3 De Line en Britt V zijhekken 18 44 a e e ee e 19 4 5 De verlenging voor de matrasbodem bevestigen 19 4 6 ann aa Cat a 20 4 7 Transporthaken 21 m Artikelnummers van de accessoires 22 Schoonmaken en 23 6 Schoonmaken cds s s sa cha n SG ERE AEN al e 23 6 3 lt 24 6 3 Onderhoud 62s a NEE ENEE ek WR n E ake ki RQ ae 25 GA karane W ne S l 25 Technische 6 26 7 Het opsporen van fouten in het elektrische systeem 27 7 2 Elektromagnetische compatibiliteit EMC 28 Technische specificaties 33 8 1 Afmetingen sis cds ENEE een 33 8 2 Voorschriften voor transport en opslag 34 8 5 Gewicht 44 4 35 Alvalverwerking a AREE al a oe ie ees oe Gi k ki ane i a dane REA AC 35 Gefeliciteerd Gefeliciteerd met uw keuze voor het verpleegbed Etude Plus van Invac
78. zwenkwielen met rem e De wielen kunnen onder bepaalde omstandigheden afgeven op verschillende soorten vloerbedekking en op onbe handelde of slecht onderhouden vloeren Bij twijfel raadt Invacare u aan om een beschermlaag tussen de wielen en 1 de vloer te plaatsen Wanneer het bed op de juiste positie staat moeten ten minste n zwenkwiel aan het hoofdeinde en n zwenkwiel aan het voeteneinde op de rem staan De rem inschakelen trap op het pedaal Pos 1 De rem losmaken trap op het ontgrendelpedaal Pos 2 Maak de rem niet met de vingers los Uw vingers kunnen anders bekneld raken Elk zwenkwiel beschikt over de mogelijkheid om de rem zowel in de lengte als in de richting van de klok vast te zetten De rem wordt met de voet bediend 3 3 Het beengedeelte aanpassen U bedient het beengedeelte door het matrashandvat op te tillen Omhoog til het matrashandvat aan het beengedeelte omhoog Omlaag til het matrashandvat aan het beengedeelte recht omhoog en laat het beengedeelte dan zakken 4 Accessoires Bij het gebruik van zijhekken je moet altijd zorgen dat de afstand tussen het bed einde en de bovenzijde van het zijhek kleiner is dan 6 cm of groter dan 32 cm Er is een risico van beklemming van de vingers op de montage en de werking van de zijhekken 4 1 Het stalen zijhek monteren of verwijderen N n Het onrusthek kan worden gemonteerd met het ontgrendelingssy steem aan het hoof