1. 9 Error Codes An error message will appear on the display if the meter fails an internal diagnostic test And it will freeze all the buttons OL Pressure or air velocity value is over the range OL Pressure value is below the range o Err air velocity or air flow is below the range 10 Replacing the Battery When the entire display shows the low battery indication the 9 V battery has fallen to a critically low voltage level and should be replaced as soon as possible 1 Take off the battery cover at the button side of the instrument 2 Remove the old battery and replace the new 9 V battery 3 Make sure that the battery is installed to the right position and connected to the proper polarisation with the battery snap 4 Put on the battery cover and let it snap in to secure 40 Statutory Notification about the Battery Regulations The delivery of many devices includes batteries which for example serve to operate the remote control There also could be batteries or accumulators built into the device itself In connection with the sale of these batteries or accumulators we are obliged under the Battery Regulations to notify our customers of the following Please dispose of old batteries at a council collection point or return them to a local shop at no cost The disposal in domestic refuse is strictly forbidden according to the Battery Regulations You can return used batteries obtained from us at no charge at the addre
2. E Em 3 Press Xx to change the station of flashing digit and j j n l TN Or w to change the flashing digit T E D ems as 4 Press button the width of duct numbers and W will be DET to store the new parameters in memory u L 8 If duct is circular the diameter of duct numbers and Dz will be n n n shown in the primary show then select the duct diameter that L you want to use in the same way 30 5 7 Auto Power Off Mode The meter enters sleep mode default That is to say the meter will automatically shut off after 20 minutes if no button press occurs for 20 minutes When the meter is in Setup mode the display off OLE SETUP SETUP mm 4 to scroll to the SLP page Press ru to indicate ON or OFF Press Unit Jer J y j until the setting you want to use appears on the display Press RAS store the new setting in memory ON sleep mode on or OFF sleep mode off Press 7 lt or _ 5 8 Menu Settin 1 When the meter is in Setup mode Press L itj option XQ 3 There are three choices for selecting SETUP SETUP 31 1 Display pressure and air velocity value 2 Display air velocity and air flow value 3 Display pressure air velocity and air flow value Avg e 4 Press nins to store the new setting in memory vw 6 Clear M
3. Do not use this instrument near high energy circuits Do not operate the equipment near strong magnetic fields motors transformers etc Do not place the equipment on damp or wet surfaces Do not place water filled containers on the equipment danger of short circuit in case of knockover of the container Do not operate the meter before the cabinet has been fully closed Comply with the warning labels and other info on the equipment The measurement instrument is not to be to operated unattended Always start with the highest measuring range when measuring unknown values Do not subject the equipment to direct sunlight or extreme temperatures humidity or dampness Do not subject the equipment to shocks or strong vibrations Keep hot soldering irons or guns away from the equipment Allow the equipment to stabilize at room temperature before taking up measurement important for exact measurements Replace the battery as soon as the battery indicator appears With a low battery the meter might produce false reading Fetch out the battery when the meter will not be used for long period Periodically wipe the cabinet with a damp cloth and mid detergent Do not use abrasives or solvents The meter is suitable for indoor use only Do not store the meter in a place of explosive inflammable substances Do not modify the equipment in any way Do not place the equipment face down on any table or work bench to prevent damaging the control
4. Reinigung des Ger tes Ger t nur mit einem feuchten fusselfreien Tuch reinigen Nur handels bliche Sp lmittel verwenden Beim Reinigen unbedingt darauf achten dass keine Fl ssigkeit in das Innere des Ger tes gelangt Dies k nnte zu einem Kurzschluss und zur Zerst rung des Ger tes f hren 2 Eigenschaften 1 Gro es LCD Display mit Hintergrundbeleuchtung 2 Relative Zeitschaltuhr bei MAX MIN und AVG bietet einen Zeitbezug f r die Messung 3 Luftdruck Luftgeschwindigkeits oder Luftmengenmessung bietet Nullpunkteinstellung 4 Gleichzeitige Anzeige von Luftdruck Luftgeschwindigkeit oder Luftmenge und Umgebungs temperatur 5 Einfache Berechnung des Bereichs eines Rechteck oder Rundkanals 6 USB Schnittstelle USB to UART Bridge Controller 4 Batteriestandanzeige und Abschaltautomatik Sleep Modus erh ht Lebensdauer der Batterie 2 3 Bedienelemente und Anschl sse am Ger t PeakTech 5145 4 14 5 13 6 7 8 12 10 11 1 Druckmesseingang 2 Referenz Druckmesseingang 3 LCD Anzeige 4 Dr cken Sie O um die Temperatureinheiten zu ndern Dr cken Sie im Setup Modus auf um zu der Einstellungsoption zu scrollen die Sie ndern m chten oder dr cken Sio A um den angezeigten Einstellwert zu erh hen Dr cken Sie im Recall Modus auf ni um die gew nschte Messwertnummer auszuw hlen FF Setu 5 Dr cken Sie zum Einschalten der Hintergrundbeleuchtu
5. 7 3 Messen der Luftmenge 1 NX Dr cken Sie um zum Luftmengenmodus zu wechseln und dr cken Sie dann die Einheit auszuw hlen 2 Das Messger t zeigt die Kanalform und Kanalgr e an Das Messger t speichert die zuletzt eingegebene Kanalform und Kanalgr Be Wenn der zu messende Ka von dem gespeicherten Kanal abweicht w hlen Sie durch Dr cken der Taste e den richtigen Kanaltyp f r die Messung rechteckig oder rund Siehe hierzu den Schritt Einstellen von Kanalform und Parametern Andern der Einstellungsoptionen Hinweise Bei der Messung von Luftdruck Luftgeschwindigkeit und Luftmenge k nnen die Funktionen HOLD Save MIN MAX AVG Zero und Setup verwendet werden 7 4 Anzeigen der Temperatur oder F aus 7 5 Halten der angezeigten Messwerte d Dr cken Sie die zero Taste um die im Display angezeigten Werte festzuhalten Das EN Display zeigt HOLD n Va 2 Dr cken Sie die zus Taste erneut um die HOLD Funktion auszuschalten Y 7 6 Anzeigen von Minimal Maximal und Mittelwerten co 1 Durch Dr cken der Taste m k nnen Sie zwischen den Messwerten Maximalwert MAX Minimalwert MIN oder Mittelwert AVG wechseln Die seit dem Aufrufen des MAX MIN AVG Modus verstrichene Zeit bzw die Zeit zu der der Minimal bzw Maximalwert gemessen wurde erscheint auf dem Display 15 2 Dr cken Sie Luftgeschwindigkeits oder Luftmengenmessung sow
6. 1 C 70 F barometrischer Druck 14 7 PSI 1013 mbar um sich der aktuellen Luftgeschwindigkeit und Luftmenge anzun hern Das Hauptdisplay gibt die Luftgeschwindigkeit wieder Das Ger t misst die Luftgeschwindigkeit und bietet 5 w hlbare Ma einheiten f r die Luftgeschwindigkeit m s Fu min km h Meile h Knoten Uni um zum Luftdruckmodus zu wechseln und dr cken Sie dann A Einheit auszuw hlen um die 2 Schlie en Sie die Schl uche an das Pitotrohr und an das Messger t an Der Input Druckanschluss am Messger t wird mit dem wei en Schlauch vom Gesamtdruckanschluss des Pitotrohrs verbunden Der Ref Druckanschluss am Messger t wird mit dem schwarzen Schlauch vom Anschluss f r den statischen Druck des Pitotrohrs verbunden Ho ro Driicken Sie wenn das Rohr den Umgebungsbedingungen gegeniiber offen steht die Taste NJ f r 2 Sekunden um das Display auf Null zu setzen JE im So 3 Flow Luftmenge Pitot Rohr Verbindung 3 Bei der Messung sollte die Spitze des Pitotrohrs in Richtung der entgegenkommenden Luft zeigen s Abb oben Vergewissern Sie sich dass die Achse des Kanals um 10 an der Str mung ausgerichtet ist Wenn der Geschwindigkeitsmesswert auf dem Display negativ ist und o Err angezeigt wird stellen Sie sicher dass die Schl uche an die richtigen Anschl sse von Messger t und Pitotrohr angeschlossen sind 14
7. 2 Dr cken Sie die Taste Rec 4 Das Display zeigt Im rechteckig oder e rund an f Uni J und W k nnen Sie zu der Option bl ttern die Sie ndern 3 Mithilfe der Tasten UN m chten Ag 4 Dr cken Sie Rec 7 um die neue Einstellung zu speichern und zur Parameter Einstellungsoption zu wechseln 5 6 Einstellen der Parameter Wenn es sich um einen Rechteckkanal handelt werden zuerst die H he des Kanals und H im Hauptdisplay angezeigt Joder Vw um das Dr cken Sie die Taste n Dezimalzeichen auszuw hlen ow Save Clear J Dr cken Sie XC um die Position der bli N zu ndern und dr cken Sie A oder blinkende Ziffer von 0 bis 9 einzustellen CA Dr cken Sie die Taste Pec Die Breite des Kanals und W werden im Hauptdisplay angezeigt um die n chste Ziffer auszuw hlen Clear J Dr cken Sie X 7 um die Position der blinkenden Ziffer zu N ndern und dr cken Sie oder um die 1 Unit j ALL blinkende Ziffer von 0 bis 9 einzustellen Dr cken Sie Rec um die neuen Parameter zu L speichern Wenn es sich um einen Rundkanal handelt zeigt das Hauptdisplay den Durchmesser des Kanals und D an W hlen Sie nun auf dieselbe Weise den Kanaldurchmesser aus den Sie verwenden m chten 10 UELI mna HUG 5 7 Abschaltautomatik Das Messger t wechs
8. Luftdrucks Luftgeschwindigkeits und Luftmengen Messwerte PRESS L schen aller Luftdruckmesswerte VEL L schen aller Luftgeschwindigkeitsmesswerte FLOW L schen aller Luftmengenmesswerte JE I BN NLL ALL SETUP SETUP clear clear 4 Dr cken Sie die Taste rit oder W bis das Display YES Ja anzeigt Dr cken Sie dann Avg um den Speicher zu l schen Rec 12 7 Messbetrieb 7 1 Messen von Luftdruck Die im Hauptdisplay angezeigte Zahl ist der Luftdruckwert Das Ger t misst ber Differenzdruck im Bereich von 5000Pa und bietet 5 w hlbare MaBeinheiten PSI mbar Pa inH2O mmH2O 1 Dr cken Sie Einheit auszuw hlen 2 Schlie en Sie einen Schlauch an den Input Anschluss an und lassen Sie den Ref Anschluss unverbunden old Zero 3 Dr cken Sie die Taste J f r 2 Sekunden um das Display auf Null zu setzen wobei das Schlauchende den Umgebungsbedingungen gegen ber offen bleibt 4 Platzieren Sie den Eingangsschlauch in einer anderen Zone als das Messger t 5 Das Messger t zeigt den Differenzdruck der Eingangszone in Bezug auf die Referenzzone an So bedeutet z B ein positiver Messwert dass der Druck in der Eingangszone gr er ist als der beim Messger tstandort bzw in seiner Referenzzone 13 7 2 Messen der Geschwindigkeit Das Messger t verwendet die normalen Umgebungsbedingungen Temperatur 21
9. m chten Nu AN unit 3 Driicken Sie aN o 4 Driicken Sie Rec NE der w bis die gew nschte Einstellung auf dem Display erscheint um die neue Einstellung zu speichern Hinweise Im MIN MAX AVG Modus ist der Setup Modus deaktiviert 5 3 Einstellen der Einheiten der Kanalabmessung 1 Dr cken Sie wenn sich das Messger t im Setup Modus befindet 7 Einstellungsoption Einheiten der Kanalabmessung zu wechseln unit Unit 4 oder Sw um zur md uf Iu un it SETUP SETUP cm FE A ER 2 Dr cken Sie die Taste R Avg ec Das Display zeigt in Zoll oder cm Zentimeter an 3 Mithilfe der Tasten Unit und x J k nnen Sie zu der Option bl ttern die Sie ndern m chten Aug 4 Dr cken Sie Rec 4 um die neue Einstellung zu speichern 5 4 Einstellen von Kanalform und Parametern Das Messger t muss sich im Parameter Setupmodus befinden Das Display zeigt den Wert der zuletzt eingegebenen Kanalform und Kanalgr e an Wenn der zu messende Kanal von dem gespeicherten Kanal abweicht suchen Sie den richtigen Kanaltyp f r die Messung rechteckig oder rund 5 5 Ausw hlen der Kanalform 1 Dr cken Sie wenn sich das Messger t im Setup Modus befindet C Einstellungsoption Kanalform Duct Shape zu wechseln UM zur Duct SETUP Duct SETUP Shape Shape 7
10. C 90 96 RH 10 30 C 75 RH 30 40 C 45 RH 17 8 2 Spezifikationen Manometer Genauigkeit 0 3 Messbereichsendwert FSO bei 25 C 0 5 Messbereichsendwert FSO 0 29 Messbereichsendwert FSO 4 Messbereichs ee NNNM 1psi 27 68 inH2O 1psi 68 947 mbar 1psi 703 072 1 mmH20 1psi 6894 6 Pa FSO Full Scale Output Differenz des Signals zwischen Null und Endpunkt des Messbereiches 18 8 3 Spezifikationen Luftgeschwindigkeit Luftgeschwindigkeit Aufl sung Genauigkeit is 1 00 80 00 f 2 5 v M bei 10 00 Meter pro Sekunde ftus ft min 200 15733 FuB pro Minute km h 3 6 288 0 Kilometers pro Stunde Die Genauigkeit ist abh ngig von MPH Geschwindigkeit und 2 24 178 66 Rohrdurchmesser Meilen pro Stunde Knoten 2 0 154 6 nautische Meilen pro Stunde 8 4 Spezifikationen Luftstr mung Rd KG lis CFM 0 99 999 ft min 0 0001 to 100 Kubik Fuss pro Minute CMM 0 99 999 m min 0 001 to 100 Kubik Meter pro Minute ft CFM ft min Luftgeschwindigkeit ft min x Fl che ft CMM m min Luftgeschwindigkeit m s x Fl che m x 60 19 8 5 Spezifikationen Temperatur C 0 to 50 0 C 0 1 1 0 C 9 Fehlercodes Eine Fehlermeldung wird auf dem Display angezeigt wenn das Messger t einen internen Diagnosetest nicht bestanden hat In diesem Fall werden alle Tasten gesperrt OL Luftdruck oder Luftge
11. IN Le IN IN 9 Press to show the air velocity press ir secondly to show the high and length of a rectangular or the diameter circular duct press eve thirdly to show the air flow press ow to show differential pressure again 10 battery cover 11 Press to turn the thermometer on or off button and hold 2 seconds to zero out the display 13 Pitot tube for measuring of airflow Ag A 14 Press rx button and hold 2 seconds to enter Recall mode In Recall mode press to calculate the sample data In Setup mode press n button to enter a Setup a Press 6 n s again to store the displayed setting in memory d 24 4 Display Elements 1 hour min anon min sec 2 TEMP Li DHT HADAR 5 r knots MPH ft min m s km h F C PSI mbar inH O mmH O Pa 16 6 PC REC MAX MIN AG 15 7 H HOLD rci Bust Il v SETUP 1 Shape p incm clear 8 9 10 11 12 25 OONDORWND min sec or hour min Display Pressure Velocity Flow or temperature modes are active Primary Display Units of air velocity Units of pressure The indication of meter communicating to PC Auto Power Off mode indicators Duct Shape choices Low battery indicator Replace the battery as soon as the low battery indicator appears Data Hold indicator The units of H W or D Entering or exiting setup mode Indicates
12. PeakTech Pr f und Messtechnik Spitzentechnologie die berzeugt PeakTech 5145 Bedienungsanleitung Operation manual Professionelles Druckdifferenz und Luftstr mungsmessger t Professional Pressure Difference amp Flow Meter Karl Oelkers e K Mess und Pr fger te Shop Hungerberg 29 D 88085 Langenargen T 07543 913150 F 07543 913159 info kometec de www kometec de 1 Sicherheitshinweise Dieses Ger t erf llt die EU Bestimmungen 2004 108 EG elektromagnetische Kompatibilit t Zur Betriebssicherheit des Ger tes und zur Vermeidung von schweren Verletzungen durch Strom oder Spannungs berschl ge bzw Kurzschl sse sind nachfolgend aufgef hrte Sicherheitshinweise zum Betrieb des Ger tes unbedingt zu beachten Sch den die durch Nichtbeachtung dieser Hinweise entstehen sind von Anspr chen jeglicher Art ausgeschlossen Dieses Ger t darf nicht in der N he hochenergetischen Schaltungen verwendet werden Ger t nicht in der N he starker magnetischer Felder Motoren Transformatoren usw betreiben Ger t nicht auf feuchten oder nassen Untergrund stellen Keine Fl ssigkeiten auf dem Ger t abstellen Kurzschlussgefahr beim Umkippen des Ger tes Nehmen Sie das Ger t nie in Betrieb wenn es nicht v llig geschlossen ist Ger t Pr fleitungen und sonstiges Zubeh r vor Inbetriebnahme auf eventuelle Sch den Im Zweifelsfalle keine Messungen vornehmen W
13. arnhinweise am Ger t unbedingt beachten Ger t darf nicht unbeaufsichtigt betrieben werden Bei unbekannten Messgr en vor der Messung auf den h chsten Messbereich umschalten Ger t keinen extremen Temperaturen direkter Sonneneinstrahlung extremer Luftfeuchtigkeit oder N sse aussetzen Starke Ersch tterung vermeiden Hei e L tpistolen aus der unmittelbaren N he des Ger tes fernhalten Vor Aufnahme des Messbetriebes sollte das Ger t auf die Umgebungstemperatur stabilisiert sein wichtig beim Transport von kalten in warme R ume und umgekehrt Ersetzen Sie die Batterie sobald das Batteriesymbol BAT aufleuchtet Mangelnde Batterieleistung kann unpr zise Messergebnisse hervorrufen Sollten Sie das Ger t f r einen l ngeren Zeitraum nicht benutzen entnehmen Sie die Batterie aus dem Batteriefach S ubern Sie das Geh use regelm Big mit einem feuchten Stofftuch und einem milden Reinigungsmittel Benutzen Sie keine tzenden Scheuermittel Dieses Ger t ist ausschlie lich f r Innenanwendungen geeignet Vermeiden Sie jegliche N he zu explosiven und entflammbaren Stoffen ffnen des Ger tes und Wartungs und Reparaturarbeiten d rfen nur von qualifizierten Service Technikern durchgef hrt werden Ger t nicht mit der Vorderseite auf die Werkbank oder Arbeitsfl che legen um Besch digung der Bedienelemente zu vermeiden Keine technischen Ver nderungen am Ger t vornehmen Messger te geh ren nicht in Kinderh nde
14. der faoal Taste 2 Sekunden lang um die Anzeige auf Null zu Zero freizugeben Dr cken Sie die setzen 13 Pitotrohr zur Messung der Luftstr mungsgeschwindigkeit Setup Modus die Avg Taste um eine Einstellungsoption aufzurufen Dr cken Sie F erneut um die angezeigte Einstellung zu speichern 4 4 Anzeigesymbole 20 1 EA a SE GL h T i 1 o c MOU TEMP Lil LI 18 3 PRESS VEL FLOW CFM CMM NULL nee a LILO ay TERN TERN ES SS 17 5 kNots MPH ft min m s km h FC 16 PSI mbar inH O mmH O Pa 6 C REC MAX MIN AG 15 7 H HoLD MEM Duct B v Setup DB 14 Shape D incm lear 13 10 11 12 oo m 13 TOE NDUP D Laufzeitanzeige Minuten Sekunden bzw Stunden Minuten Anzeige der Modi Luftdruck Luftgeschwindigkeit Luftmenge oder Temperatur Hauptdisplay Einheiten f r Luftgeschwindigkeit Einheiten f r Luftdruck Anzeige der Kommunikation zwischen Messger t und PC Anzeige des automatischen Abschaltmodus Kanalform Auswahl Batteriezustandsanzeige Anzeige f r DATA Hold Messwerthaltefunktion Die Einheiten von H he H und Breite W Rechteckkanal oder Durchmesser D Rundkanal Setupmodus Anzeige Zeigt an dass ein gespeicherter Messwert oder alle Messwerte aus dem Speicher gel scht werden Zeigt an dass auf den Messwertspeicher zugegriffen wird und die Nummer
15. der Messwerte Zeigt an dass auf den Messwertspeicher zugegriffen wird Anzeigen f r REC MAX MIN und AVG Temperatureinheiten f r das Hauptdisplay Einheiten f r Luftmenge Temperatureinheiten f r das Sekund rdisplay Sekund rdisplay Temperatur und Zeit 5 ndern der Einstellungsoptionen Verwenden Sie den Setup Modus f r die Auswahl der Kanalform und das Einstellen der Kanalparameter des Schlafmodus der Men einstellungen f r den Max Min Avg Modus und der Speicherl schung Das Messger t speichert diese Einstellungen in seinem Speicher Einstellungsoptionen Einheiten der Unit Einstellen der Einheiten f r die Kanalabmessung Einheit Kanalabmessung Zoll in oder Zentimeter cm Kanalform und Duct Shape Einstellen des Messbereichs f r Parameter Kanalform Luftmenge Automatischer Automatische Abschaltung Ein Abschaltmodus On bzw Aus Off Men einstellung ee 4 1 2 oder 3 Speicherl schung Pe Ja Yes oder Nein No 5 1 Aktivieren oder Verlassen des Setup Modus Wenn das Messger t im Setup Modus ist zeigt das Display SETUP an Dr cken Sie die Setup Taste f r 2 Sekunden um den Setup Modus zu aktivieren oder zu verlassen 5 2 ndern einer Einstellungsoption Mithilfe der Tasten f unit und XW k nnen Sie zu der Option bl ttern die Sie ndern m chten f Avg 2 Dr cken Sie Rec 7 um anzugeben dass Sie diese Einstellung ndern
16. e for the measurement rectangular or round Refer to Step duct shape and parameters setting Changing Setup Options Notes HOLD Save MIN MAX AVG Zero and Setup can be used when measuring pressure velocity and flow 7 4 Displaying Temperature Ambient temperature is displayed on the secondly show as a reference The temperature can be displayed in either C or F Press to select unit C or F 7 5 Holding the Displayed Readings FA La f Hold 1 Press Zero to freeze the readings on the display The display shows HOLD f aea 2 Press Hold Vers J again to turn off the HOLD function 7 6 Viewing the MIN MAX and AVG Readings EN MAX 1 Press ey to step through the maximum MAX minimum MIN or the average AVG readings The elapsed time since entering MAX MIN AVG mode or the time at which the minimum or maximum occurred appears on the display IN 2 Press to show the maximum minimum and average of pressure velocity or flow and temperature value N MAX 3 Press button for 2 seconds to exit MAX MIN AVG mode id 85 7 7 Saving Samples The Meter saves various samples in its three major modes To save a sample do the following Save 1 When taking a sample press to store the sample The Meter can save up to 99 samples in each of its three modes 2 If the memory is full 99 samples have been stored more samples cannot be stored If the u
17. elt standardm ig in den Schlafmodus Das hei t das Messger t schaltet sich automatisch nach 20 Minuten Inaktivit t ab Wenn das Messger t im Setup Modus ist zeigt das Display I i SLEEP SLEEP SETUP SETUP e Einstellung gew nschte Einstellung auf dem Display erscheint Dr cken Sie noc J NE zu speichern ON Schlafmodus ein oder OFF Schlafmodus aus 5 8 Einstellen des Men s 1 Dr cken Sie wenn sich das Messger t im Setup Modus befindet Einstellungsoption Modusmen type zu wechseln 2 Mithilfe der Tasten m chten 3 Es stehen drei Auswahlm glichkeiten zur Verf gung 3 EIE ESPE SETUP SETUP 11 1 Zeigt den Luftdruck und Luftgeschwindigkeitswert an 2 Zeigt den Luftgeschwindigkeits und Luftmengenwert an 9 Zeigt den Luftdruck den Luftgeschwindigkeits und den Luftmengenwert an Rec um die neue Einstellung zu speichern 4 Dr cken Sie 6 L schen des Speichers YAN unit 1 Dr cken Sie wenn sich das Messger t im Setup Modus befindet 6der NY um zur Einstellungsoption L schen des Speichers ALL Clear zu wechseln CON Avg 2 Dr cken Sie dann Rec um die Funktion zu best tigen Save 3 Dr cken Sie C um den gew nschten Messwert auszuw hlen Es stehen drei Auswahlm glichkeiten zur Verf gung PRESS VEL FLOW L schen aller
18. emory Setting 1 When the meter is in Setup mode Press J it option to scroll to the clear memory setup Save 2 Press NE to select the desired sample There are three choices for selecting PRESS VEL FLOW clear all pressure velocity and flow sample data PRESS clear all pressure sample data VEL clear all velocity sample data FLOW clear all flow sample data YES T ui ILL HLL SETUP SETUP clear clear 9 then clear the memory 7 Operation 7 1 Measuring Pressure The Primary Display number is Pressure value the device measures Gauge Differential Pressure 5000Pa it features 5 selectable units of measure PSI mbar Pa inH2O mmH2O IN a Unit 1 Press V to enter the pressure mode and press to select unit udi WY 2 Connect a single hose to the Input port leaving the Ref port unconnected d Sy 3 With the tubing open to ambient conditions press 355 and hold for 2 seconds to zero out the display NJ 4 Place the input hose in a different zone than the Meter 5 The Meter displays the differential pressure of the input zone with respect to the reference zone For instance a positive reading means that the input zone is positively pressured with respect to the Meter location or its reference zone 33 7 2 Measuring Velocity The Meter uses standard ambient conditions temperature 21 1 C 70 F barome
19. etup Options 8 Specifications 8 1 General Specifications Operating Conditions 0 to 50 C lt 80 RH Storage Conditions 10 to 60 C lt 80 RH Power Supply 9V Battery Dimensions WxHxD 75x203x50mm Accessories Pitot Tube 12 Inch black and white hose usb cable software for windows 2k XP VISTA 7 battery and operation manual Relative Humidity 10 C 90 RH 10 C to 30 C 75 RH 30 C to 40 C 45 RH 37 8 2 Manometer specification Accuracy 0 3 FSO 25 C Repeatability 0 5 FSO Linearity Hysteresis 0 29 FSO Maximum Pressure Pee Ng Under range Indicator m 1psi 27 68 inH2O 1psi 68 947 mbar 1psi 703 072 1 mmH20 1psi 6894 6 Pa FSO Full Scale Output The difference signal between zero and end point of range 38 8 3 Range of Air Velocity m s 2 5 of reading 1 00 80 00 meter per second at 10 00 m s ft min 200 15733 feet per minute km h 3 6 288 0 accuracy is function kilometers per hour of velocity and duct size MPH 2 24 178 66 miles per hour Knots 2 0 154 6 nautical miles per hour 8 4 Range of Air Flow CFM 0 99 999ft3 min 0 0001 to 100 cubic feet per minute CMM 0 99 999m3 min 0 001 to 100 cubic meters per minute CFM ft3 min Air Velocity ft min x Area ft2 CMM m3 min Air Velocity m s x Area m2 x 60 39 8 5 Range of Temperature ee MS C 0 to 50 0 C 0 1 1 0 C
20. ie den Temperaturwert anzuzeigen um den Maximal Minimal und Mittelwert der Luftdruck N 3 Zum Verlassen des MAX MIN AVG Modus dr cken Sie die iit Taste f r 2 Sekunden Iu 7 7 Speichern der Messwerte Das Messger t speichert in seinen drei Hauptmodi zahlreiche Messwerte Gehen Sie zum Speichern folgendermaBen vor f save 1 Dr cken Sie bei einer Messung die Nela Taste um den Messwert zu speichern Das Messger t kann bis zu 99 Messwerte in jedem seiner drei Modi speichern 2 Wenn der Speicher voll ist 99 Messwerte wurden gespeichert k nnen keine weiteren Messwerte gespeichert werden Wenn der Benutzer versucht einen weiteren Messwert zu speichern zeigt das Messger t FU an und speichert den neuen Messwert nicht 7 8 Abrufen und L schen von Messwerten Das Messger t speichert Messwerte die manchmal abgerufen und periodisch gel scht werden m ssen Dabei k nnen einzelne Messwerte oder der gesamte Speicher gel scht werden Wenn der Speicher voll ist 99 Messwerte wird FU Full voll auf dem Display angezeigt sobald e gedr ckt wird Das Messger t r gibt ein akustisches Signal von sich und speichert einen neuen AEE Messwert erst wenn gespeicherte Messwerte gel scht wurden PRESS Zum Abrufen von Messwerten gehen Sie folgendermaBen vor 3 has 1 1 Driicken Sie um Messwerte des ausgewahlten Modus abzurufen ba Ang MEM 2 Dr cken Sie dann die Rec d RECALL Tas
21. ng auf N erneut um die Hintergrundbeleuchtung wieder auszuschalten Dr cken Sie die S Taste f r 3 Sekunden um den Setup Modus zu aktivieren oder zu verlassen siehe ndern der Einstellungsoptionen Unt 6 Dr cken Sie w um die angezeigten Einheiten zu ndern Dr cken Sie im Setup Modus f Un um zu der Einstellungsoption zu scrollen die Sie ndern m chten oder dr cken Sie AN um den angezeigten Einstellwert zu erh hen Dr cken Sie im Recall Modus auf it um die gew nschte Messwertnummer auszuw hlen EN f Save Save 7 Dr cken Sie 9 um Messwerte zu speichern oder dr cken Sie die Taste rum Messwerte im Recall Modus zu l schen FIR mar 8 Dr cken Sie ZEN um zwischen den Maximum Minimum und Mittelwerten zu wechseln MAX Dr cken Sie die Taste 2 Sekunden lang um den MAX MIN AVG Modus zu verlassen und zum normalen Betrieb zur ckzukehren N N 9 Dr cken Sie um die Luftgeschwindigkeit anzuzeigen Dr cken Sie dann erneut C um die H he und Breite eines Rechteckkanals bzw den Durchmesser eines Rundkanals anzuzeigen N a 4 IN Dr cken Sie evr ein weiteres Mal um die Luftmenge anzuzeigen Dr cken Sie nun evr um wieder den Differenzdruck anzuzeigen 10 Batteriefach 11 Ein bzw Ausschalten des Messger ts f i Hold 12 Dr cken Sie die Taste Ne um die Anzeige der Messwerte festzuhalten bzw wie
22. s at the front Opening the equipment and service and repair work must only be performed by qualified service personnel Measuring instruments don t belong to children hands 1 1 Cleaning the cabinet Clean only with a damp soft cloth and a commercially available mild household cleanser Ensure that no water gets inside the equipment to prevent possible shorts and damage to the equipment 22 Features Large LCD display with backlight Relative time clock on MAX MIN and AVG provides a time reference for measurement Pressure velocity or air flow measurement provides Zero Adjust Display pressure Air velocity or air flow plus environment Temperature simultaneously Easy to calculate the area of a rectangular or circular duct USB interface USB to UART Bridge Controller Low battery indication and Auto Power Off mode Sleep mode increases battery life Front Panel Description B tt PeakTech 5l45 12 10 11 23 1 pressure input 2 differential pressure 3 LCD display Recall mode press Unit o select the desired sample number 2t FIC oi Sav 7 Press Va Clear button to store sample data or press Na button to clear sample data in Recall X N mode gt N max MIN 8 Press G _ to step through the maximum minimum and average readings To exit the MAX MIN AVG mode press the m button for 2 seconds to return to normal operation M
23. schwindigkeit liegen au erhalb des Messbereiches OL Der Luftdruckwert liegt unterhalb des Messbereiches o Err Luftgeschwindigkeit oder Luftmenge liegt au erhalb des Messbereiches 10 Austausch der Batterien Bei ungen gender Batteriespannung leuchtet in der LCD Anzeige das Batteriesymbol auf Bei leuchtendem Batteriesymbol sind exakte Messergebnisse nicht mehr gew hrleistet Die Batterie ist verbraucht und sollte baldm glichst ausgewechselt werden Dazu wie beschrieben vorgehen 1 Batteriefachabdeckung auf der R ckseite abnehmen 2 Verbrauchte Batterie aus dem Batteriefach entfernen und vom Batteriekabel abziehen 3 Neue 9 V Batterie an Batteriekabel anschlie en und Batterie in Batteriefach einsetzen 4 Batteriefachdeckel wieder auflegen und mit nach oben dr cken bis der Batteriefachdeckel einschnappt Gesetzlich vorgeschriebene Hinweise zur Batterieverordnung Im Lieferumfang vieler Ger te befinden sich Batterien die z B zum Betrieb von Fernbedienungen dienen Auch in den Ger ten selbst k nnen Batterien oder Akkus fest eingebaut sein Im Zusammenhang mit dem Vertrieb dieser Batterien oder Akkus sind wir als Importeur gem Batterieverordnung verpflichtet unsere Kunden auf folgendes hinzuweisen Bitte entsorgen Sie Altbatterien wie vom Gesetzgeber die Entsorgung im Hausm ll ist laut Batterieverordnung ausdr cklich verboten an einer kommunalen Sammelstelle oder geben Sie sie im Handel vor Ort kostenlos ab Von
24. ser attempts to store another sample the Meter shows FU and does not save new readings 7 8 Recall and Clearing Sample Data The Meter stores data that sometime will need to be recall and periodically to be cleared Individual samples or the entire data memory can be cleared When the memory is full 99 samples it shows FU Full on the display when ear IS pressed and the Meter emits short beeps and will not save any value unless some samples are cleared To recall sample data do the following zs r 1 Press to recall samples for that mode L PRESS 2 Press V RECALL and hold the button for 2 seconds 3 to recall samples The last measurement saved appears first J Use m and to locate the desired sample p unm Pa 3 Once the samples are taken press adve to view the 1 MEM RA average of all the samples bc Ag 4 Press eco and hold the button for 2 seconds to exit ES recall mode 36 To clear individual sample data do the following to recall samples for that mode AN RECALL and hold the button for 2 seconds to recall samples Use Unit 3 to select the desired sample sme Save 3 Press rear to clear the sample Note that the number of samples displayed is reduced N 4 4 Press Rec and hold the button for 2 seconds to exit recall mode To clear all sample data Refer to Step clear memory setting Changing S
25. ss on the last side in this manual or by posting with sufficient stamps Batteries which contain harmful substances are marked with the symbol of a crossed out waste bin similar to the illustration shown left Under the waste bin symbol is the chemical symbol for the harmful substance e g Cd for cadmium Pb stands for lead and Hg for mercury You can obtain further information about the Battery Regulations from the Bundesministerium f r Umwelt Naturschutz und Reaktorsicherheit Federal Ministry of Environment Nature Conservation and Reactor Safety This manual considers the latest technical knowing Technical changings which are in the interest of progress reserved We herewith confirm that the units are calibrated by the factory according to the specifications as per the technical specifications We recommend to calibrate the unit again after 1 year PeakTech 05 2012 th Ho PeakTech Pr f und Messtechnik GmbH Kornkamp 32 DE 22926 Ahrensburg Germany T 49 0 4102 42343 44 151 49 0 4102 434 16 E info peaktech de www peaktech de
26. te f r 2 bc Sekunden um die Messwerte abzurufen Der zuletzt gespeicherte Messwert wird zuerst angezeigt W hlen Sie mithilfe der Pfeiltasten iS den gew nschten Messwert aus mA N 16 3 Dr cken Sie sobald alle Messwerte genommen wurden die Taste nang um den Mittelwert aller gespeicherten Messwerte anzuzeigen 4 Dr cken Sie die nec 7 RECALL Taste f r 2 Sekunden um den Abruf Modus zu verlassen ee Zum L schen von Messwerten gehen Sie folgenderma en vor A 1 Dr cken Sie um Messwerte des ausgew hlten Modus abzurufen Ag 2 Dr cken Sie dann die Rec RECALL Taste f r f BN ekunden um die Messwerte abzurufen lt und Unit den gewinschten Messwert aus W hlen Sie mithilfe der Pfeiltasten m u V Save 3 Driicken Sie ger um den gew nschten Messwert zu l schen Beachten Sie dass sich die Anzahl der angezeigten Messwerte reduziert Avg 4 Dr cken Sie die RC RECALL Taste f r 2 Sekunden um den Abruf Modus zu verlassen Lesen Sie den Abschnitt L schen des Speichers ndern der Einstellungsoptionen Nu 8 Technische Daten 8 1 allgemeine Spezifikationen Spannungsversorgung 9V Batterie Abmessungen BxHxT 75x203x50 mm Zubeh r Pitotrohr 12 schwarze und wei er Verbindungsschlauch USB Kabel Software f r Windows 2k XP VISTA 7 Batterie und Bedienungsanleitung Luftfeuchtigkeit 10
27. that a stored sample or all samples is about to be deleted from memory The sample memory is being accessed and the number of samples Annunciators showing that sample memory is being accessed REC MAX MIN and AVG indicators Temperature units of primary display Units of air flow Temperature units of secondly display Digits for temperature and time 26 5 Changing Setup Options Use Setup to chose duct shape and set the duct parameters sleep mode Max min avg mode menu setting and clear memory The thermometer stores the settings in its memory Setup Options Duct dimension units hl Set duct dimension units in or cm Duct Shape and Duct Shape set area of measuring air flow parameters Auto Power Off mode auto off or on pn ERES UNE CERES pue eM 5 1 Entering or Exiting Setup When the thermometer is in Setup mode the display shows SETUP Press Setup s button for 2 seconds start or exit Setup Cu 27 5 2 Changing a Setup Option f unit 1 Press Avg 2 Press Rec 3 Press Unit Press Av Rec_ ur Notes Setup is disabled in MIN MAX AVG mode 5 3 Duct dimension units Setting 1 When the meter is in Setup mode press Unt 4 setup option v to scroll to the setup option you want to change to indicate that you want to change this setting or NY until the setting you want to use appears on the display 9 to s
28. tore the new setting in memory f Unit or NW to scroll to the duct dimension units un i SETUP un i SETUP cm 2 Press 3 Press IZ 4 Press n ho store the new setting in memory 28 a P button It shows in or cm on the display YAN Unit A Unit f or to scroll to the setup option you want to change j 5 4 Duct Shape and Parameters Setting When the meter is in parameters setup mode The screen is show number of the last duct shape and size that is entered If the duct is different than the stored version then find the proper duct type for the measurement rectangular or round 5 5 Choose Duct Shape 1 When the meter is in setup mode press to scroll to the duct shape setup option Duct SETUP Duct SETUP Shape Shape ha m e 2 Press Rec_ button The screen shows the rectangle or circular m nit 3 Press Unit or AZ to scroll to the setup option you want to change Avg 4 Press Rec to store the new setting in memory and enter parameters setup option 29 5 6 Parameters Setting 1 If duct is rectangle the height of duct numbers and H will be first shown in the primary show AN m Unit i NW 2 Press Vor Y point gave 5 Clear Press Unit from Oto 9 shown in the primary show 7 Press Rec button to select the decimal
29. tric pressure 14 7 PSI 1013 mbar to approximate actual velocity and flow The primary display number is air velocity the device measures air velocity and it features 5 selectable units of velocity measure m s ft min km h MPH knots 1 Press Pwr to enter Velocity mode and press yj to select unit 4 NV p 2 Connect the hoses to the pitot tube to the Meter The Input pressure port on the Meter connects to the white hose from the total pressure connection of the pitot tube The Ref pressure port on the Meter connects to the black hose from the static prassure connection of the pitot tube the tubing open to ambient conditions press and hold pos for 2 seconds to zero out the display NJ fg lt lt L Flow Pitot Tube Connection 34 3 When make the measurement the pitot tube tip should against the measured wind as shown in upper figure and ensure that the axis of the duct is aligned with the fluid flow for 10 If Measure Velocity measures negative and show o Err on the display check to make sure that the hoses are attached to the correct ports on the Meter and the pitot 7 3 Measuring Flow IN 1 Press F to enter air flow mode and press 2 The Meter shows the duct shape and size The Meter stores the duct shape and size that is entered Ifthe duct is different than the stored version press Setup button to find the proper duct typ
30. uns erhaltene Batterien k nnen Sie nach Gebrauch bei uns unter der auf der letzten Seite angegeben Adresse unentgeltlich zur ckgeben oder ausreichend frankiert per Post an uns zur cksenden 20 Batterien die Schadstoffe enthalten sind mit dem Symbol einer durchgekreuzten M lltonne gekennzeichnet hnlich dem Symbol in der Abbildung links Unter dem M lltonnensymbol befindet sich die chemische Bezeichnung des Schadstoffes z B CD f r Cadmium Pb steht f r Blei und Hg f r Quecksilber Weitere Hinweise zur Batterieverordnung finden Sie beim Bundesministerium f r Umwelt Naturschutz und Reaktorsicherheit Letzter Stand bei Drucklegung Technische nderungen des Ger tes welche dem Fortschritt dienen vorbehalten Hiermit best tigen wir dass alle Ger te die im unseren Unterlagen genannten Spezifikationen erf llen und werkseitig kalibriert geliefert werden Eine Wiederholung der Kalibrierung nach Ablauf von einem Jahr wird empfohlen PeakTech 05 2012 th Ho 21 1 Safety Precautions This product complies with the requirements of the following European Community Directives 2004 108 EC Electromagnetic Compatibility To ensure safe operation of the equipment and eliminate the danger of serious injury due to short circuits arcing the following safety precautions must be observed Damages resulting from failure to observe these safety precautions are exempt from any legal claims whatever