Contents
1. 8 Mem Save Measured Values in MEMOTY 2 eee 9 Mem Edit Overwrite a Saved Measured Value 10 Mem Recall Data Memory Recall 11 Mem Clear Clear Memory 12 GMC I Messtechnik GmbH Page USB Port Standard Software 12 Accessories 13 Standard Equipment 13 Optional Accessories 13 Calibration Certificate 14 DAKkS Certificate 14 Service and Maintenance 14 Specifications 14 Declaration of Conformity 18 1 Applications The SECULIFE IT illuminance meters are handy easy to use and high precision measuring instruments They allow the accurate measurement of the illuminance in the unit Ix or fc Combined with the Luminance Attachment available as optional accessory the SECULIFE IT can also be used for measuring luminance in the unit cd m or fL The light sensor is color corrected i e its relative spectral responsivity has been adapted to that of the human eye VA All the important types of light can be measured with high precision without the necessity to apply any additional correction factors The accuracy of that V 4 adaptation is the main difference between the two types SECULIFE TC M688E and SECULIFE IT M688A The quality classes for illuminance meters have been defined in the Standard Speci
2. 4 4 3 Mem Edit Uberschreiben eines gespeicherten Messwerts 10 4 4 4 Mem Recall Auslesen des Messwertspeichers 4 4 5 Mem Clear L schen des gesamten Messwertspeichers 11 7 7 4 4 Speicherfunktionen z 8 8 Konformit tserkl rung 9 GMC I Messtechnik GmbH 3 1 Anwendung Mit dem Beleuchtungsst rkemessger t SECULIFE IT haben Sie ein handliches bequem zu bedienendes und genaues Messger t erworben Das Ger t ist zur exakten Bestimmung der Beleuchtungsst rke in den Einheiten Ix oder fc geeignet Mit einem als Zubeh r erh ltlichen Vorsatz kann das SECULIFE IT auch zur Messung der Leuchtdichte in cd m oder fL eingesetzt werden Der lichtempfindliche Sensor ist farbkorrigiert d h seine Spektralempfindlichkeit ist der spektralen Hellempfindlichkeit des menschlichen Auges V 4 angepasst Sie k nnen also alle wichtigen Lichtarten mit hoher Genauigkeit messen ohne Korrekturfaktoren ber cksichtigen zu m ssen Der Unterschied zwischen SECULIFE ITC M688E und SECULIFE T M688A besteht vor allem in der G te dieser Anpassung Die Klasseneinteilung f r Beleuchtungsst rkemessger te ist in DIN 5032 Teil 7 festgelegt SECULIFE ITC entspricht hierbei den Anforderungen der Klasse C SECULIFE T denen der Klasse B Die Lichteintrittsfl che mit zus tzlicher Ringblende des Photometerkopfes ist so ausgelegt dass schr g einfallendes Licht cos
3. Make Measurement Press down the on off key and the SECULIFE IT will start up in measuring mode and will immediately be measuring at 2 times per second The instrument is in the function AUTO i e the SECULIFE IT will select the best suited measuring range for the existing light level By pressing one of the range keys one of the measuring ranges can be set Scrolling up or down through additional measuring ranges is accomplished by briefly pressing one of the range keys If both keys are pressed and held simultaneously the instrument is returned to AUTO RANGING 4 2 Selecting the Measurement Unit Ix or fc cd m or fL Use the key Ix fe to select the required unit for the read out lux or footcandle With the additional Luminance Attachment please refer to 6 2 Optional accessories this key also selects the measurement unit for luminance cd m or fL candela per square meter or footlambert 4 3 Overload Display Zero Point Indication When exceeding one of the measuring ranges OL Overload appears in the display rn Jen r The zero point indication may be achieved by putting the protective cap over the light collector of the photometer head GMC I Messtechnik GmbH 7 4 4 Memory Functions In addition to the display buffer storage the SECULIFE IT has also been provided with a memory space for up to 100 measured values This function allows the user to make several measurements in the field and
4. 10 GMC I Messtechnik GmbH 4 4 4 Mem Recall Auslesen des Messwertspeichers Mem Ausgehend von der Funktion Messen dr cken Sie die Taste Mem Es wird der letzte belegte Speicherplatz zuerst angezeigt Durch Druck auf eine der Range Tasten kann durch den Speicher geblattert werden Der aktuelle Speicherplatz li wird abwechselnd mit dem gespeicherten Messwert angezeigt Durch Druck auf eine beliebige andere Taste oder wenn Sie ca 10 Sekunden keinen weiteren Speicher ber die Range Tasten abrufen gelangen Sie wieder in die Messfunktion GMC I Messtechnik GmbH 11 4 4 5 Mem Clear L schen des gesamten Messwertspeichers Das SECULIFE T muss sich in der Funktion HOLD befinden Durch gleichzeitiges Dr cken der Range Tasten wird der gesamte Messwertspeicher gel scht Im Display wird die L schung durch 3 Striche best tigt HOLD 5 USB Schnittstelle Standard Software Das SECULIFE IT besitzt eine USB Schnittstelle Diese erm glicht die Verbindung zum PC ber das mitgelieferte USB Kabel Auf der dem SECULIFE IT beiliegenden CD ROM befindet sich u a eine Standard Software mit der Sie sofort in den PC Betrieb einsteigen k nnen N here Informationen zum PC Betrieb finden Sie ebenfalls auf dieser CD ROM Mit der Standardsoftware gLux kann der Messwertspeicher ausgelesen und SECULIFE T gesteuert werden automatische Messung von 2x pro Sekunde bis 1x t glich Bei der Darstellung k nne
5. Im Display erscheint HOLD Durch erneuten Druck auf die Taste Hold wechselt das SECULIFE IT wieder in die Messfunktion Hold Die Funktion Hold ist die Ausgangsfunktion f r alle Speicherfunktionen 8 GMC I Messtechnik GmbH 4 4 2 Mem Messwert speichern Hold Mem Der zu speichernde Messwert wird durch die Taste Hold im im Display festgehalten Durch Dr cken der Taste Mem wird der zu speichernde Wert auf den nachsten freien Speicherplatz abgelegt Im Display wird der gespeicherte Messwert abwechselnd mit der Nummer des Speicherplatzes f r einige Sekunden angezeigt Anschlie end wechselt das SECULIFE IT wieder in die Messfunktion Ist der Speicher mit 100 Messwerten belegt wird dies mit FLL im Display angezeigt GMC I Messtechnik GmbH 4 4 3 Mem Edit berschreiben eines gespeicherten Messwert Hold Um einen irrt mlich im Messwertspeicher abgelegten Wert zu korrigieren hat das SECULIFE IT die Funktion Mem Edit Sie messen den zu korrigierenden Messwert neu und halten diesen mit der Taste Hold fest Durch Druck auf eine der Range Tasten t kann durch den Speicher geblattert werden Bei dem zu Uberschreibenden Speicherplatz dr cken Sie jetzt die Taste Mem Im Display wird der gespeicherte Messwert abwechselnd mit der Nummer des Speicherplatzes fur einige Sekunden angezeigt Anschlie end wechselt das SECULIFE IT wieder Mem in die Messfunktion AUTO Ix ai
6. GmbH Lisa Ammon Str 22 90471 Nurnberg Phone 49 0 911 8602 181 14 GMC I Messtechnik GmbH 8 Specifications Light Sensor Classification Measuring Rate LCD display Read out Overload signal Memory Interface Power Supply Battery Battery life Battery test External Silicon photo diode with V A filter SECULIFE ITC M688E MAVOLUX 5032C USB Class C according to DIN 5032 Part 7 CIE 69 SECULIFE IT M688A MAVOLUX 5032B USB Class B according to DIN 5032 Part 7 CIE 69 2 measurements per second 50 mm x 25 mm SECULIFE T 5032 B USB back lighted display 7 segments 3 digits 13 mm OL in the display 100 memory space measured values display indication FLL memory full USB 1 1 Port one 1 5 V AA alkaline manganese cell Size AA IEC LR 6 or suitable rechargeable battery approx 45 hour continuous operation with alkaline manganese battery Automatic display of 4 symbol when battery voltage drops below 1 0 Volt When the SECULIFE IT is connected to a PC power will be supplied by the PC via the USB cable GMC I Messtechnik GmbH 15 Weights and Dimensions Housing Dimensions Weight Light sensor Cable length Plastics Display Unit 65 x 120 x 19 mm 2 56 x 4 73 x 0 75 without carrying case Photometer Head 31 x 105 x 30 mm 1 22 x 4 13 x 1 18 tripod socket 1 4 on bottom side Display unit and photometer head approx 200 g without battery Light sensitive s
7. IT 3 1 Vorbereitung Setzen Sie zuerst die beiliegende Batterie 1 5V Mignon Batterie IEC LR6 in die Batteriekammer ein ffnen Sie hierzu den Schnappverschluss des Batteriefachs an der R ckseite des SECULIFE IT Achten Sie dabei auf die richtige Polarit t Die Polungsrichtung ist durch einen Pr gedruck in der Batteriekammer gekennzeichnet Ist die Kapazit t der Batterie ersch pft werden Sie durch die Anzeige a im Display gewarnt Bei einem Batteriewechsel bleiben die im Messwertspeicher abgelegten Werte erhalten 3 2 Anzeigedauer Dauerbetrieb Falls f r ca 4 Minuten keine Bedientaste des SECULIFE T gedr ckt wird schaltet das Ger t automatisch ab Die im Messwertspeicher abgelegten Werte sowie die individuellen Einstellungen bleiben erhalten Die automatische Abschaltung l sst sich unterdr cken wenn Sie beim Einschalten zus tzlich die Taste Hold gedr ckt halten Der Dauerbetrieb wird Ihnen im Display durch Blinken der Messeinheit angezeigt 6 GMC I Messtechnik GmbH 4 Bedienung 41 Einschalten und Messen Schalten Sie das Ger t durch Dr cken der Taste on off ein Das SECULIFE IT ist sofort in Messfunktion und misst 2 mal pro Sekunde Nach dem Einschalten befindet sich das Messger t im Messbereich Auto d h entsprechend des Lichtniveaus schaltet das SECULIFE IT in den g nstigsten Messbereich Durch Druck auf eine der Range Tasten l sst sich einer der Messbereiche fixieren Durch weiteren kurzen Druck
8. a standard software which permits the immediate start of the operation by PC More details about the PC operational functions are also available on that CD Rom With the standard software gLux the memory can be read and SECULIFE IT can be controlled automatic measurements from 2 times per second up to 1 time per day The values can be presented as a chart or as graphics and be transferred to customer specific calculations 12 GMC I Messtechnik GmbH 6 6 1 6 2 Accessories Standard Equipment Aluminium Case Battery Protective cover cap Standard Software on CD ROM USB cable Instruction Manual Optional Accessories Luminance Attachment cd m and fL Order Code Z688A Measures the reflected light i e the luminance of a surface with a measuring angle e ho approx 15 By a micro switch the SECULIFE T automatically detects the luminance attachment screwed onto the light measuring probe The measured luminance value is displayed correctly in value and unit Please keep in mind that the luminance attachment is adapted to the light collector of 10 mm older luminance attachments can not be used The luminance attachment can not be used for classified luminance measurements Adapter disc for Luminance attachment Order Code Z688B The adapter disk may easily be plugged onto the luminance attachment For all kinds of screens the light of the room will be shielded The measuring results will be more precise if you use the adapter
9. auf eine der Range Tasten werden die Messbereiche auf oder abw rts weiter geschaltet Durch gleichzeitiges Dr cken beider Tasten k nnen Sie wieder auf Messbereichsautomatik umstellen 4 2 Wahl der Anzeigeneinheit Ix fc cd m fL Mit der Taste Ix fc kann die gew nschte Anzeigeeinheit Lux oder footcandle gew hlt werden Wenn Sie einen Leuchtdichtevorsatz siehe Punkt 6 2 Optionales Zubeh r verwenden so kann die entsprechende Anzeigeeinheit f r Leuchtdichte cd m oder fL eingestellt werden 4 3 berlaufanzeige Nullpunktanzeige Bei berschreiten eines Messbereichs erscheint OL overload im Display IX Die Nullpunktanzeige kann durch Aufsetzen der mitgelieferten Schutzkappe auf das Lichteintrittsfenster des Photometerkopfes erzeugt werden jt m s GMC I Messtechnik GmbH 7 4 4 Speicherfunktionen Das SECULIFE IT besitzt neben einem Anzeige Zwischenspeicher noch einen Messwertspeicher mit 100 Speicherpl tzen Diese Funktion erm glicht Ihnen mehrere Messungen vor Ort vorzunehmen und zu einem sp teren Zeitpunkt auszulesen Die gespeicherten Werte bleiben bei Ausschalten des Ger tes oder bei einem Batteriewechsel erhalten 4 4 1 Hold Zwischenspeicher Um Ihnen z B die M glichkeit zu geben in dunkler Umgebung zu messen und anschlie end im Hellen den Messwert abzulesen hat das SECULIFE IT einen Anzeige Zwischenspeicher Bei Druck auf die Taste Hold wird die letzte Messung im Display festgehalten
10. getreu bewertet wird St rkstes Licht Tageslicht Scheinwerfer kann ohne weiteres Zubeh r mit beiden Ger ten gemessen werden Insbesondere SECULIFE IT ist mit seinem um eine Dekade erweiterten Messumfang auch zur Messung geringer Beleuchtungsst rken z B an Notbeleuchtungen hervorragend geeignet Die Ger te besitzen einen Messwertspeicher mit 100 Speicherpl tzen der sowohl direkt ber Tastatur und Display als auch ber die eingebaute USB Schnittstelle und der im Lieferumfang enthaltenen Standard Software ausgelesen und weiterverarbeitet werden kann Ix Lux 1 Ix 0 0929 fc fc footcandle 1 fc 10 76 Ix cd m Candela pro m 1 cd m 0 2919 fL fL footLambert 1 fL 3 426 cd m 4 GMC I Messtechnik GmbH 2 Anzeigefeld 2 1 Das Anzeigefeld und seine Elemente 2 2 Das Tastenfeld 5 4 D AUTO x1000 IX xio u HT vt 1 2 3 I un en am am ee cd m on off Autof Ix fe DA En Hold Range Mem 4 5 6 Messwert und Speicheranzeige Messeinheit Zwischenspeicher Faktor Messwert Auto Range automatische Messbereichswahl Batteriewarnanzeige SECULIFE T mit automatischer Hintergrundbeleuchtung in der Hold Funktion GMC I Messtechnik GmbH on off Ein Ausschalten Range Taste Speicher Messbereich Ix fc Messeinheit umschalten Hold Zwischenspeicher Range Taste Speicher Messbereich M Mem Speichertaste OG RON gt OG ROGON gt 3 So funktioniert das SECULIFE
11. glichkeit EMV Nach Richtlinie 89 336 EWG vom 01 01 1996 16 GMC I Messtechnik GmbH Kennwerte SECULIFE IT in Lux Ix in footcandle fc in Ix in fc Beleuchtungsstarke 1 001 1999 0 001 1999 001 0 001 Hof 01 199 001 190 O1 00 Im 1 199 O1 1999 1 ony I inCandelaim cd m infootlamben fL inodm inft Leuchtdichte L 01 199 97 001 19 99 01 001 mit Leuchtdichte Hof ae 1999 01 1999 o vorsatz m 10 19990 1 1999 Ot f r cd m oder fL Wichtigste Fehlergrenzen SECULIFE IT Merkmal Zul ssige Fehlergrenze nach Typischer Fehler DIN 5032 Klasse B V0 Anpassung f GMC I Messtechnik GmbH 17 V A Anpassung f SECULIFE IT Typ SECULIFE IT 100 90 vin Typ 5032B 80 70 60 50 40 30 20 10 0 380 400 420 440 460 480 500 520 540 560 580 600 620 640 660 680 700 720 740 760 780 nm 18 GMC I Messtechnik GmbH EG KONFORMITATSERKLARUNG C DECLARATION OF CONFORMITY GOSSEN Dokument Nr Document No 102 2004 Hersteller Manufacturer GOSSEN Foto und Lichtmesstechnik GmbH Anschrift Address Thomas Mann Str 16 20 90471 N rnberg Produktbezeichnung Product name Beleuchtungsst rkemessger t Luxmeter Footcandle meter Typ Type MAVOLUX 5032 B USB Bestell Nr Order No M503G Das bezeichnete Produkt stimmt mit den Vorschriften folgender Europ ischer Richtlinien berein nachgewiese
12. support gossenmetrawatt com Erstellt in Deutschland nderung vorbehalten Eine PDF Version finden Sie im Internet 7 GOSSEN METRAWATT Telefon 49 911 8602 111 GMC I Messtechnik GmbH Fax 49 911 8602 777 S dwestpark 15 E Mail info gossenmetrawatt com 90449 N rnberg Germany www gossenmetrawatt com 24 GMC I Messtechnik GmbH Operating Instructions A GOSSEN METRAWATT SECULIFE IT and ITC 15507 IIluminance Tester 2 2 14 USB Port SECULIFE HOLD AUTO Display Caw pie Key pad Back of display unit battery door Re serial number GOSSEN METRAWATT calibration seal for DAkkS or calibration certificate if available Perspective view of SECULIFE IT 2 Photometer head Circular orifice Light collector Back of photometer head serial number of display unit tripod socket GMC I Messtechnik GmbH Contents 4 3 4 4 4 4 1 4 4 2 4 4 3 4 4 4 4 4 5 Page Applications 4 Display u bio P oe ads ka dva da n 5 Description of Display Elements 5 Key Padi cb lite alia Uda adel 5 Functioning of the SECULIFE 6 Preparation eee 6 Duration of Display Continuous Operation u ne 6 SECULIFE IT Operation 7 Switch On Make Measurement 7 Selecting the Measuring Unit Ix or fe cd m OF fl 7 Overload Display Zero Point Indication 7 Memory Functions 8 HOLD Display Hold Function
13. Bedienungsanliung A GOSSEN METRAWATT SECULIFE IT und ITC 15507 Illumination Tester 2 2 14 SOSSEN METRAWATT Photometerkopf USB SECULIFE Schnittstelle T 7 C Ringblende Display IH 1 com g Tastenfeld Lichtempf nger Unterseite des Photometerkopfes Unterseite der Anzeigeeinheit POSE AL Seriennummer der Batteriefachdeckel Anzeigeeinheit Seriennummer Stativgewinde Kalibriersiegel fur DAkkS oder Werkskalibrierschein falls vorhanden Ger teansicht SECULIFE IT 2 GMC I Messtechnik GmbH Inhaltsverzeichnis 1 Anwendung Seite Seite 5 USB Schnittstelle Anzeigefeld ee 5 Standard Software 12 2 1 Das Anzeigefeld und seine Elemente 5 2 2 Das Tastentfeld i cc cccscssececsnerssseesteneees 5 6 Zubehor 13 6 1 Im Lieferumfang enthalten we 13 3 So funktioniert das SECULIFE 6 6 2 Optionales Zubeh r oe 13 3 1 Vorbereitung a 6 6 3 Werkskalibrierschein 3 2 Anzeigedauer Dauerbetrieb 6 14 6 4 DAkkS Kalibrierschein 14 4 Bedienung en 7 4 1 Einschalten und Messen 7 Service Hinweis 14 4 2 Wahl der Anzeigeneinheit Ix fc cd m fL 4 3 berlaufanzeige Nullpunktanzeige 8 Technische Daten 15 4 4 1 Hold Zwischenspeicher bad 4 4 2 Mem Messwert speichern
14. H 13 6 3 Werkskalibrierschein Werkskalibrierschein auf Anforderung fur SECULIFE IT ITC M688G M688l 1 KI Die R ckf hrung der Messergebnisse wird Uber die Wissenschaftliche G Normallampe Wi 41G an das Nationale Normal der PTB in Braunschweig gew hrleistet Je nach Einsatz des Ger tes empfehlen wir ein Kalibrierintervall oy von 12 bis 24 Monaten Wenden Sie sich hierzu bitte an unseren Kalibrierservice Telefon 49 0 911 8602 172 6 4 DAkkS Kalibrierschein DAkkS Kalibrierschein auf Anforderung f r SECULIFE IT ITC M688H M688J Mit unserem ISO IEC EN 17025 akkreditiertem Kalibrierlabor D K Registriernummer D K 15080 01 00 des DAkkS f r Beleuchtungsst rke bieten wir das h chstm gliche industrielle Niveau f r die Durchf hrung ee und R ckf hrbarkeit von Kalibrierungen zur Lichtmessung 7 Service Hinweis Das Ger t ben tigt bei vorschriftsm igem Gebrauch keine besondere Wartung Sollte das Ger t durch den Gebrauch verschmutzt worden sein reinigen Sie die Geh useoberfl che mit einem leicht angefeuchteten Tuch Vermeiden Sie den Einsatz von Putz Scheuer oder L sungsmitteln Sollte Ihr SECULIFE T einmal nicht zu Ihrer Zufriedenheit arbeiten oder wollen Sie Ihren Werks bzw DAkkS Kalibrierschein erneuern lassen senden Sie ihn an GOSSEN Foto und Lichtmesstechnik GmbH Lisa Ammon Str 22 90471 N rnberg Tel 49 0 911 8602 181 14 GMC I Messtechnik GmbH 8 Technische Daten Lichtempfange
15. Juni 2004 Ort Datum Place date Diese Erkl rung bescheinigt die bereinstimmung mit den genannten Richtlinien beinhaltet jedoch keine Zusicherung von Eigenschaften Die Sicherheitshinweise der mitgelieferten Produktdokumentationen sind zu beachten 22 Vorsitzender der Gesch ftsf hrung This declaration certifies compliance with the above mentioned directives but does not include a property assurance The safety notes given in the product documentations which are part of the supply must be observed GMC I Messtechnik GmbH GMC I Messtechnik GmbH is also a leading provider of further interesting light measuring instruments SECULIFE IM High quality and precision instrument for measuring luminance classified according to the Standard Specifications DIN 5032 Part 7 Class B and CIE 69 The measuring sensor to be placed directly on the luminous or back lighted surface may be used for contact measurement such as i e monitors TV screens light boxes light panels illuminated advertising boards traffic sign etc SECULIFE IA For precision spot metering of the luminance with a measuring angle of 1 degree under consideration of the ambient light The sensitive light sensor is colour corrected i e its spectral sensitivity is adapted to the spectral brightness sensitivity of the human eye V W according to DIN 5032 Part 7 Class B The SECULIFE IA is especially suited for inspecting and constancy testing of viewing monit
16. LARUNG C DECLARATION OF CONFORMITY GOSSEN Dokument Nr Document No 101 2004 Hersteller Manufacturer GOSSEN Foto und Lichtmesstechnik GmbH Anschrift Address Thomas Mann Str 16 20 90471 N rnberg Produktbezeichnung Product name Beleuchtungsst rkemessger t Luxmeter Footcandle meter Typ Type MAVOLUX 5032 C USB Bestell Nr Order No M502G Das bezeichnete Produkt stimmt mit den Vorschriften folgender Europ ischer Richtlinien berein nachgewiesen durch die vollst ndige Einhaltung folgender Normen The above mentioned product has been manufactured according to the regulations of the following European directives proven through complete compliance with the following standards Nr No Richtlinie Directive 73 23 EWG Elektrische Betriebsmittel zur Verwendung Electrical equipment for use within certain voltage 73 23 EEC innerhalb bestimmter Spannungsgrenzen limits Niederspannungsrichtlinie Anbringung der CE Kennzeichnung 2003 Low Voltage Directive Attachment of CE mark 2003 EN Norm Standard IEC Deutsche Norm VDE Klassifikation Classification EN 61010 1 1993 IEC 61010 1 1992 VDE 0411 1 1994 EN 61557 3 1997 IEC 61557 3 1997 VDE 0413 3 1997 Nr No Richtlinie Directive 89 336 EWG Elektromagnetische Vertraglichkeit Electromagnetic compatibility 89 336 EEC EMV Richtlinie EMC directive Fachgrundform Generic Standard EN 61326 2002 N rnberg den 24
17. MC I Messtechnik GmbH Switch On Off Range key Memory Measuring range Ix fc Select measuring unit HOLD Function Buffer Storage Range key Memory Measuring range MEM Memory key OGORON gt OG RON gt 3 Functioning of the SECULIFE IT 3 1 Preparation First remove the snap on cover of the battery compartment at the back of the meter Insert the battery included in the delivery contents 1 5 V size AA IEC LR6 in the battery compartment Care should be taken to place the battery correctly according to the polarity indications and in the battery compartment When the battery warning symbol 4 appears in the display the battery must be replaced The values in the measuring data memory and also the preset individual values will be maintained even when the battery is changed 3 2 Duration of Display Continuous Operation If for approx 4 minutes none of the keys of the SECULIFE IT is pressed down the instrument will be turned off automatically When the instrument is switched off the values stored in the measuring data memory and also the preset individual values will be maintained You can override the automatic switch off when you switch on the instrument and simultaneously keep the HOLD key pressed down The measuring unit Ix fc in the display will blink and indicate that the Continuous Operation Mode is on 6 GMC I Messtechnik GmbH 4 SECULIFE T Operation 4 1 Switch On
18. cumentations which are part of the supply must be observed 19 Kennwerte SECULIFE ITC in Lux Ix in footcandle fc in Ix in fc Beleuchtungsstarke 01 199 001 1999 01 0 01 I ae 1969101 1999 ony m 0 19900 1 199 1 I in Candelalm cd m Leuchtdichte I 3 de 1999 01 Tel A o mit Leuchtdichte Hof 10 19990 1 1999 of 1 vorsatz m 100 199900 10 19990 to 19 f r cd m oder fL Wichtigste Fehlergrenzen SECULIFE ITC DIN 5032 Klasse C V A Anpassung f Linearit tsfehler 4 Abgleichfehler fii Gesamtfehler fes 15 0 20 GMC I Messtechnik GmbH V A Anpassung f SECULIFE ITC Typ SECULIFE ITC 100 90 Typ 5032C vy 80 70 60 50 30 20 10 0 380 400 420 440 460 480 500 520 540 560 580 600 620 640 660 680 700 720 740 760 780 nm GMC I Messtechnik GmbH EG KONFORMITATSERKLARUNG C DECLARATION OF CONFORMITY GOSSEN Dokument Nr Document No 101 2004 Hersteller Manufacturer GOSSEN Foto und Lichtmesstechnik GmbH Anschrift Address Thomas Mann Str 16 20 90471 N rnberg Produktbezeichnung Product name Beleuchtungsst rkemessger t Luxmeter Footcandle meter Typ Type MAVOLUX 5032 C USB Bestell Nr Order No M502G Das bezeichnete Produkt stimmt mit den Vorschriften folgender Europ ischer Richtlinien berein nachgewiesen durch die vollst ndige Einhaltung folgender Normen The above men
19. d Lichtmesstechnik GmbH Anschrift Address Thomas Mann Str 16 20 90471 N rnberg Produktbezeichnung Product name Beleuchtungsst rkemessger t Luxmeter Footcandle meter Typ Type MAVOLUX 5032 B USB Bestell Nr Order No M503G Das bezeichnete Produkt stimmt mit den Vorschriften folgender Europ ischer Richtlinien berein nachgewiesen durch die vollst ndige Einhaltung folgender Normen The above mentioned product has been manufactured according to the regulations of the following European directives proven through complete compliance with the following standards Nr No Richtlinie Directive 73 23 EWG Elektrische Betriebsmittel zur Verwendung Electrical equipment for use within certain voltage 73 23 EEC innerhalb bestimmter Spannungsgrenzen limits Niederspannungsrichtlinie Anbringung der CE Kennzeichnung 2003 Low Voltage Directive Attachment of CE mark 2003 EN Norm Standard IEC Deutsche Norm VDE Klassifikation Classification EN 61010 1 1993 IEC 61010 1 1992 VDE 0411 1 1994 EN 61557 3 1997 IEC 61557 3 1997 VDE 0413 3 1997 Nr No Richtlinie Directive 89 336 EWG Elektromagnetische Vertraglichkeit Electromagnetic compatibility 89 336 EEC EMV Richtlinie EMC directive Fachgrundform Generic Standard EN 61326 2002 N rnberg den 24 Juni 2004 Ort Datum Place date Diese Erkl rung bescheinigt die bereinstimmung mit den genannten Richtlinien b
20. d key and the new value is logged in Then by pressing one of the range keys you can scroll through the memory At the memory space to be corrected press down the key Mem Then the display shows the saved value for a few seconds alternating with the number of the memory space Subsequently the SECULIFE IT will return to Mem measuring mode GMC I Messtechnik GmbH 4 4 4 Mem Recall Data Memory Recall Mem Start in the function Measuring and press down the key Mem The last memory space filled will be displayed first Strike one of the Range keys to scroll through the data memory The current memory space is displayed as 01 02 alternating t with the measured value saved in the memory To return to the measuring mode just press down any one of the other keys or if for about ten seconds no further memory data is recalled by the Range keys the SECULIFE IT will return to the measuring mode GMC I Messtechnik GmbH 11 4 4 5 Mem Clear Clear Memory The SECULIFE T must be in function HOLD Pressing down the Range keys simultaneously will clear the complete measuring data memory The cancelling is confirmed in the display by three dashes HOLD 5 USB Port Standard Software The SECULIFE IT is equipped with a USB Port which allows the meter to be connected to a PC by the USB cable in the delivery contents The CD Rom supplied with the SECULIFE IT contains among other information
21. disc On sensitive surfaces the contact pressure is reduced by the big surface of the adapter disc Therefore the risk of damage during the measurement will be reduced considerably GMC I Messtechnik GmbH 13 6 3 Calibration Certificate Optional The traceability of the measuring results is guaranteed by our calibration reference Scientific Standard Lamps type Wi 41G of the PTB ge n a Physikalisch Technische Bundesanstalt Braunschweig National Standard Institute of Germany Depending on how the instrument is being used we 3 A27 recommend a recalibration interval between 12 and 24 month For this purpose gt please contact our Calibration Service Department telephone 49 911 8602 172 6 4 DAkks Certificate Optional With our calibration laboratory accredited according to ISO IEC EN 17025 for illuminance registration number D K 15080 01 00 of DAkkS we can offer you the highest industrial level for the performance and traceability of calibrations for light metering 2011 11 7 Service and Maintenance No special maintenance is required if the SECULIFE IT is being handled correctly Keep the outside surfaces clean Use a slightly dampened cloth for cleaning Do not use cleansers abrasives or solvents Should the instrument nevertheless not work to your satisfaction or if you will require repeated calibration with calibration or DAkkS certificate please send the SECULIFE IT to GOSSEN Foto und Lichtmesstechnik
22. einhaltet jedoch keine Zusicherung von Eigenschaften Die Sicherheitshinweise der mitgelieferten Produktdokumentationen sind zu beachten GMC I Messtechnik GmbH Vorsitzender der Gesch ftsf hrung This declaration certifies compliance with the above mentioned directives but does not include a property assurance The safety notes given in the product documentations which are part ofthe supply must be observed 19 Characteristics SECULIFE ITC Measuring Quantity Measuring Range Measuring Range Resolution Resolution Per moe infoteadle illumination tT 01 199 001 19 99 01 0 01 I f o 119991 01 1999 af on m 10 19900 1 199 tO Poin Candela m cd m infootlambent fL incdm inf Luminance o 3 1 1999 199 9 tO with luminance Wf 10 19990 1 1999 Ot attachment m 100 199900 10 19990 100 10 for cd m or fl Most Important Error Limits SECULIFE ITC Characteristics Admissible Error according to Typical Error DIN 5032 Klasse C V Adaptation f1 True Cosine Evaluation f Linearity f Adjustment Error fii Overall Error fes 15 0 20 GMC I Messtechnik GmbH V A Adaptation f SECULIFE ITC 100 90 80 70 60 50 30 20 10 0 Typ SECULIFE ITC x Typ 5032C vy 380 400 420 440 460 480 500 520 540 560 580 600 620 640 660 680 700 720 740 760 nm GMC I Messtechnik GmbH 780 21 EG KONFORMITATSERK
23. fications DIN 5032 Part 7 Consequently the SECULIFE TC complies with Class C SECULIFE T complies with Class B DIN 5032 part 7 and 8 The light collector with circular orifice in the photometer head has integrated cosine correction so that oblique incident light will be measured accurately Both SECULIFE IT ITC types allow measuring very high intensity light daylight headlights without additional accessories Especially the SECULIFE IT having an initial sensitivity of 0 01 Ix is ideally suited for measuring extremely low light intensities such as emergency lighting The instruments are provided with a measuring value memory with 100 data spaces which can be read and processed directly by the keys and the display but also through the integrated USB Port and the Standard Software supplied with the meters Ix Lux 1 Ix 0 0929 fc fc footcandle 1 fc 10 76 Ix cd m Candela per square meter 1 cd m 0 2919 fL fL footlambert 1fL 3 426 cd m 4 GMC I Messtechnik GmbH 2 Display 2 1 Description of Display Elements 2 2 Key Pad i io HOLD AUTO x1000 Ix fc 3 n H Ya ee an a am on em cd m on off Autof Ix fe DAD am m am Hold Range Mem 4 5 6 Display of measuring value and Memory Measuring Unit Display HOLD indication Buffer Storage Multiplying factor for measuring value Auto ranging automatic range selection Low Battery SECULIFE IT 5032 B USB with automatic backlight in HOLD function G
24. n Sie zwischen tabellarisch und grafisch w hlen Die ausgelesenen Messwerte k nnen in nutzereigene Kalkulationen bernommen werden 12 GMC I Messtechnik GmbH 6 6 1 6 2 Zubeh r Im Lieferumfang enthalten Alukoffer Batterie Lichtdichte Schutzkappe Standard Software auf CD ROM USB Kabel Bedienungsanleitung Optionales Zubeh r Leuchtdichtevorsatz cd m und fL Best Nr Z688A Erfasst das reflektierte Licht also die Helligkeit einer Fl che mit einem Messwinkel e 4o ca 15 Das SECULIFE IT erkennt durch einen Kontaktschalter am Messkopf ob der Leuchtdichtevorsatz aufgeschraubt ist Der Leuchtdichtemesswert wird auf diese Weise mit richtigem Zahlenwert und Einheit auf der Anzeige ausgegeben Bitte beachten Sie Der Leuchtdichtevorsatz ist abgestimmt auf den Diffusor mit 10mm 2 ltere Leuchtdichtevors tze k nnen nicht verwendet werden Der Leuchtdichtevorsatz ist nicht geeignet f r klassifizierte Leuchtdichtemessungen Adapterscheibe zum Leuchtdichtevorsatz Best Nr Z688B Die Adapterscheibe wird ganz einfach auf den Leuchtdichtevorsatz aufgesteckt Bei allen Arten von Monitoren Bildschirmen wird Licht aus dem Raum abgeschirmt Die Folgen sind genauere Messergebnisse bei Nutzung der Adapterscheibe bei empfindlichen Oberfl chen wird der Auflagedruck durch die gro e Oberfl che der Scheibe vermindert Die Gefahr der Besch digung bei Messungen wird dadurch wesentlich vermindert GMC I Messtechnik Gmb
25. n durch die vollst ndige Einhaltung folgender Normen The above mentioned product has been manufactured according to the regulations of the following European directives proven through complete compliance with the following standards Nr No Richtlinie Directive 73 23 EWG Elektrische Betriebsmittel zur Verwendung Electrical equipment for use within certain voltage 73 23 EEC innerhalb bestimmter Spannungsgrenzen limits Niederspannungsrichtlinie Low Voltage Directive Anbringung der CE Kennzeichnung 2003 Attachment of CE mark 2003 EN Norm Standard IEC Deutsche Norm VDE Klassifikation Classification EN 61010 1 1993 IEC 61010 1 1992 VDE 0411 1 1994 EN 61557 3 1997 IEC 61557 3 1997 VDE 0413 3 1997 Nr No Richtlinie Directive 89 336 EWG Elektromagnetische Vertraglichkeit Electromagnetic compatibility 89 336 EEC EMV Richtlinie EMC directive Fachgrundform Generic Standard EN 61326 2002 N rnberg den 24 Juni 2004 Ort Datum Place date Diese Erkl rung bescheinigt die bereinstimmung mit den genannten Richtlinien jedoch keine Zusicherung von Eigenschaften Die Sicherheitshinweise Produktdokumentationen sind zu beachten GMC I Messtechnik GmbH Vorsitzender der Gesch ftsf hrung This declaration certifies compliance with the above mentioned beinhaltet directives but does not include a property assurance The safety der mitgelieferten notes given in the product do
26. ors in medical applications according to DIN 6868 57 Other applications are projection screens street surfaces and street lightings illumination of tunnels and sport areas SECULIFE S For monitoring the ambient light in the surroundings of monitors according to IEC 61223 2 5 QS RL dt 20 11 2003 The use of the SECULIFE IS permits the prolongation of the required repeat test intervals of the veil luminance and the maximum contrast at medical imaging displays to six months GMC I Messtechnik GmbH 23 Product Support If required please contact GMC I Messtechnik GmbH Product Support Hotline Phone 49 911 8602 0 Fax 49 911 8602 709 E Mail support gossenmetrawatt com Edited in Germany Subject to change without notice A PDF version is available on the Internet GOSSEN METRAWATT Phone 49 911 8602 111 GMC I Messtechnik GmbH Fax 49 911 8602 777 S dwestpark 15 E Mail info gossenmetrawatt com 90449 N rnberg Germany www gossenmetrawatt com 24 GMC I Messtechnik GmbH
27. r Silizium Fotodiode mit V A Filter Klassifizierung SECULIFE ITC M688E MAVOLUX 5032C USB Klasse C nach DIN 5032 Teil 7 SECULIFE IT M688A MAVOLUX 5032B USB Klasse B nach DIN 5032 Teil 7 Messrate 2 Messungen pro Sekunde Digitalanzeige LCD Anzeigefeld 50 mm x 25 mm bei SECULIFE IT hintergrundbeleuchtet Anzeige Ziffernh he 7 Segment Ziffern 13 mm Stellenzahl 3 stellig berlaufanzeige OL wird eingeblendet Messwertspeicher 100 Speicherpl tze intern Anzeige FLL Speicher voll Schnittstelle USB 1 1 Stromversorgung Batterie 1 5 V Mignon Alkali Mangan Zelle IEC LR 6 oder entsprechender Akku Betriebsdauer ca 45 Stunden Dauerbetrieb mit Alkali Mangan Batterie Batteriekontrolle Automatische Anzeige von H wenn Batteriespannung kleiner ca 1 0 V Extern Bei PC Betrieb erfolgt die Stromversorgung ber die USB Schnittstelle GMC I Messtechnik GmbH 15 Mechanischer Aufbau Geh use Kunststoff Abmessungen Anzeigeeinheit 65 x 120 x 19 mm ohne Bereitschaftstasche 2 56 x 4 73 x 0 75 Photometerkopf 31 x 105 x 30 mm 1 22 x 4 13 x 1 18 Gewindeanschluss 1 4 auf der Unterseite Gewicht Anzeigeeinheit und Photometerkopf ca 200 g ohne Batterie Lichtempfanger Lichtauffangfl che des Diffusors ca 10 mm mit zus tzlicher Ringblende Die Lage der Referenzebene ist auf der Oberflache der Lichteintrittsflache Kabellange ca 1 5 m gegen Aufpreis erh ltlich 3 m 5 m und 10 m Elektromagnetische Vertr
28. sstechnik GmbH GMC I Messtechnik GmbH ist ebenso ein f hrender Hersteller weiterer interessanter Lichtmessgerate SECULIFE IM Digitales Prazisionsmessgerat zum Messen der Leuchtdichte klassifiziert nach DIN 5032 Teil 7 und CIE no 69 in Klasse B Direkt aufgesetzt an selbstleuchtenden oder an durchstrahlten Fl chen anzuwenden an Monitor Fernsehbildschirm Leuchtpult Lichtwanne Leuchtreklame Verkehrsschilder SECULIFE IA zur Pr zisionsmessung der Leuchtdichte mit Messwinkel 1 unter Ber cksichtigung des Umgebungslichts Der lichtempfindliche Sensor ist farbkorrigiert d h seine Spektralempfindlichkeit ist der spektralen Hellempfindlichkeit des menschlichen Auges V X nach DIN 5032 Teil 7 der Klasse B angepasst Mit SECULIFE IA ist u a fur Abnahme und Konstanzpr fungen an Betrachtungsmonitoren in der Medizintechnik nach DIN 6868 57 geeignet Weitere Anwendungsgebiete sind Projektionsw nde Stra enbelag und beleuchtungen Tunnel und Sportstattenbeleuchtungen SECULIFE IS Raumlicht berwachung entspr IEC 61223 2 5 QS RL vom 20 11 2003 Bei Einsatz des Ger tes verl ngert sich der Pr fzyklus an Bildwiedergabegeraten bei Schleierleuchtdichte und Maximalkontrast auf ein halbes Jahr GMC I Messtechnik GmbH 23 Produktsupport Bitte wenden Sie sich im Bedarfsfall an GMC I Messtechnik GmbH Hotline Produktsupport Telefon D 0900 1 8602 00 A CH 49 911 8602 0 Telefax 49 911 8602 709 E Mail
29. then to view them later The data stored in the memory will be maintained even if the meter is turned off or if the battery is changed 4 4 1 HOLD Display Hold Function The SECULIFE IT has been equipped with a Display HOLD Function in order to enable you to make measurements in very low light conditions and to read them out later in brighter light conditions The latest measurement will be buffer stored in the display by striking the HOLD key Then HOLD will appear in the display Pressing down the HOLD key again will prompt the SECULIFE IT to return to the measuring function HOLD AUTO fc Hold IE ul The function HOLD is the basic function for all the memory functions 8 GMC I Messtechnik GmbH 4 4 2 Mem Save Measured Values in Memory Hold Mem The measurement measured value which is to be saved will be maintained by the Hold key in the display and may be filed onto the next free memory space by pressing down key Mem Then for a few seconds the display shows the saved measured value alternating with the number of the memory space After that the SECULIFE IT returns into the measuring mode If the memory space is filled with all 100 memory spaces then the display will show FLL GMC I Messtechnik GmbH 4 4 3 Mem Edit Overwrite a Saved Measured Value Hold The SECULIFE IT offers the function Mem Edit for correcting a stored value in the memory Measure again press the Hol
30. tioned product has been manufactured according to the regulations of the following European directives proven through complete compliance with the following standards Nr No Richtlinie Directive 73 23 EWG Elektrische Betriebsmittel zur Verwendung Electrical equipment for use within certain voltage 73 23 EEC innerhalb bestimmter Spannungsgrenzen limits Niederspannungsrichtlinie Anbringung der CE Kennzeichnung 2003 Low Voltage Directive Attachment of CE mark 2003 EN Norm Standard IEC Deutsche Norm VDE Klassifikation Classification EN 61010 1 1993 IEC 61010 1 1992 VDE 0411 1 1994 EN 61557 3 1997 IEC 61557 3 1997 VDE 0413 3 1997 Nr No Richtlinie Directive 89 336 EWG Elektromagnetische Vertraglichkeit Electromagnetic compatibility 89 336 EEC EMV Richtlinie EMC directive Fachgrundform Generic Standard EN 61326 2002 N rnberg den 24 Juni 2004 Ort Datum Place date Diese Erkl rung bescheinigt die bereinstimmung mit den genannten Richtlinien beinhaltet jedoch keine Zusicherung von Eigenschaften Die Sicherheitshinweise der mitgelieferten Produktdokumentationen sind zu beachten 22 Vorsitzender der Gesch ftsf hrung This declaration certifies compliance with the above mentioned directives but does not include a property assurance The safety notes given in the product documentations which are part of the supply must be observed GMC I Me
31. urface of the diffuser approx 10 mm with circular orifice Location of the reference plane is on the surface of the light collector Approx 1 5 m Available on special order available 3 m 5 m and 10 m Electromagnetic Compatibility EMC The SECULIFE IT meets the German specifications 89 336 EWG 01 01 1996 16 GMC I Messtechnik GmbH Characteristics SECULIFE IT in Lux Ix in footcandle fc in Ix in fc Illumination L 001 1999 0 001 1999 0 010 001 M 01 199 001 19 01 00 Im 1 1999 01 1999 af ony I inCandelaim cd m infootlamben fL inodm inft Luminance I 01 1999 001 1999 TT 001 with luminance Hof 0 3 1 1999 01 Tl Hl 0 attachment mf 10 19990 1 1999 of for cd m or fL Most Important Error Limits SECULIFE IT Characteristics Admissible Error according to Typical Error DIN 5032 Class B V Adaptation f1 True Cosine Evaluation f Linearity f Adjustment Error fii Overall Error fes GMC I Messtechnik GmbH 17 V A Adaptation f SECULIFE IT Typ SECULIFE IT 100 T 90 vy Typ 5032B 80 70 60 50 40 30 20 10 0 380 400 420 440 460 480 500 520 540 560 580 600 620 640 660 680 700 720 740 760 780 nm 18 GMC I Messtechnik GmbH DECLARATION OF CONFORMITY C EG KONFORMIT TSERKL RUNG GOSSEN Dokument Nr Document No 102 2004 Hersteller Manufacturer GOSSEN Foto un
Download Pdf Manuals
Related Search
Related Contents
ProTeam 107252 Instructions / Assembly TITAN OFF-ROAD TitanMaxAirComp Use and Care Manual Certrec Action Tracking System (CATS) User Manual Manual Batedeira de Cereais ZHC618F-500C/1000W User`s Manual Samsung S105 Cellular Phone 家庭用電位治療器(見え消し版) ダイニングコタツ取扱説明書(保証書付) Page 1 Page 2 この度はーロ-55ー をお買上げいただきありがとうござい Manual de referencia del Wrapper .NET para Copyright © All rights reserved.