Contents
1. 10 St 40 mF 10 uF 40 mF Bereich Anzeige ist nur f r Referenzzwecke 3 7 Diodentest Bereich Aufl sung Leerlauf berspannungs spannung schutz 4V 1mV 3 V 600 Vss 3 8 Frequenzmessungen Bereich Aufl sung Genauigkeit berspannungs schutz 4 kHz 1 Hz 40 kHz 10 Hz 400 kHz 100 Hz 4 MHz 1 kHz 0 1 3 St 600 Vss 40 MHz 10 kHz 400 MHz 100 kHz Eingangs Empfindlichkeit lt 40MHz lt 200 mVer lt 100MHZ lt 1 Ver gt 100MHz Nur Referenzwert 10 3 9 Temperaturmessungen Bereich Aufl sung Genauigkeit 40 C 40 C 0 C 3 4 St 1000 C 1 C 0 C 400 C 1 3 St 400 C 1000 C 2 10 St 40 F 40 F 32 F 3 4 St 1832 F TSE 32 F 752 F 1 4 St 752 F 1832 F 2 5 berspannungsschutz 600Vss 3 10 Durchgangspr fung Summer ert nt bei weniger als 402 Uberlastschutz 600Vss 11 4 Bedienelemente und Anschl sse am Ger t 12 LCD Display Funktionswahlschalter COM Eingangsbuchse V Q Hz Diode Eingangsbuchse HA mA Eingangsbuchse 10A Eingangsbuchse Ein Aus Taste Zum Ein und Ausschalten des Ger tes 8 Messwerthaltefunktions Taste DATA HOLD Die Data Hold Funktion erm glicht das Einfrieren eines Messwertes zum sp teren Ablesen in der LCD Zur Aktivierung der Data Hold Funktion HOLD Taste dr cken Es erscheint das H Sy
2. WARNING Never connect the test leads to a source of voltage when you have the selected the OHMS function and plugged the test leads into the V Q Hz P terminal Be sure that the circuit under test has all power removed and that any associated capacitors are fully discharged before you make a resistance measurement The resistance measuring circuit compares the voltage gained through a known resistance internal with the voltage developed across the unknown resistance So when you check in circuit resistance be sure the circuit under test has all power removed all capacitors are fully discharged 48 a Set the rotary selector to the desired OHM range 2 Plug the black test lead into your meter s COM terminal and the red test lead into your meter s V Q Hz terminal 3 Connect the test leads to the device you want to measure Notes If the measured resistance value exceeds the maximum value of the range selected OL appears flashes This indicates an overload Select a higher range In this mode the beeper does not sound When you short the test leads in the 400Q range your meter displays a small value no more than 0 3Q This value is due to your meters and test leads internal resistance Make a note of this value and subtract it from small resistance measurements for better accuracy 6 4 Checking diodes This function lets you check diodes and other semiconductors for opens and shorts It also
3. that is fuse protected by 1mA 250V fuse To avoid electrical shock or instrument damage do not connect the C Common Input COM terminal to any source of 1000V DC AC with respect to earth ground Be exceptionally careful when measuring high voltages Do not touch the terminals or test lead ends Refer to the complete operating instructions BP Wt Indicates protection class Il double insulation CAT III IV Overvoltage category III IV 33 AC DC AC and DC Grounding ER Battery Symbol N Continuity test F Diode test 4 Capacitance test Fuse ce Conforms to standards of the European Union 1 2 Input Limits Function Terminal Input Limits VDC 1000 V DC 750 V ACms VAC vaz com 1000 V DC 750 V ACms Q 600 V DC AC mA DC AC HA mA COM 1 A 250 V DC AC 10 A DC AC 10 A COM 10 A 250 V DC AC J 600 V DC AC Frequency 600 V DC AC Temperature V Q Hz I COM 600 V DC ACpp Capacitance 600 V DC AC 34 2 Introduction The multimeter is heavy duty and rugged hand held multimeter that will give you confidence and peace of mind in your every measuring job Please read these operating instructions very carefully before commencing your measurements Data Hold Function freezes the display so you can keep the measured value there even after you discon
4. 10 mV 1 5 dgt 1000 V DC 400 V 100 mV 750 V AC 750 V 1 V 1 2 5 dgt Input impedance 10MQ Displays effective value of sine wave mean value response Frequency 40Hz 400Hz 3 3 DC current measurement Range Resolution Accuracy Overload protection 400 uA 100 nA 1 2 dgt 1 A 250 V 4000 yA 1 uA 40 mA 10 pA 1 2 3 dgt 400 mA 100 pA 10 A 10 mA 1 5 5 dgt 10 A 250 V 10 A Range For continuous measurement lt 10 seconds and interval not less than 15 minutes 37 3 4 AC current measurement Range Resolution Accuracy Overload protection 400 uA 100 nA 1 5 5 dgt 1A 250 V 4000 uA 1 uA 40 mA 10 uA 2 5 dat 400 mA 100 uA 10 A 10 mA 2 5 5 dgt 10 A 250 V 400uA 400mA range Displays effective value of sine wave mean value response 10A Range For continuous measurement lt 10 seconds and interval not less than 15 minutes Frequency 40Hz 400Hz 3 5 Resistance Test Range Resolution Accuracy Overload protection 400 Q 0 12 1 2 2 dgt 4 kQ 1 Q 40 kQ 10 Q 1 2 dgt 400 kQ 100 Q 4 MQ 1 kQ 1 2 2 dgt 600 Vie 40 MQ 10 kQ 1 5 2 dgt 4000 40MQ range Open circuit voltage approx 3V 38 3 6 Capacitance Range Resolution Accuracy Overload protection 4 nF 1 pF
5. Interface Programm zu arbeiten wird folgende Hard und Software ben tigt IBM PC oder kompatiblen Computer Microsoft Windows 2000 XP Vista 7 Mindestens 512 MB RAM Arbeitsspeicher Mindestens 8 MB freier Speicher auf der Festplatte Einen freien seriellen PC Anschluss oder USB Anschluss 8 2 Installation des PeakTech 3315 Interface Program Zur Installation des Interface Programms beachten Sie bitte die folgenden Schritte 1 Legen Sie die mitgelieferte CD ROM in Ihr CD ROM oder DVD Laufwerk 7 Doppelklicken Sie auf Arbeitsplatz auf Ihrem Windows Desktop Doppelklicken Sie auf das Symbol Ihres CD ROM oder DVD Laufwerks um das Verzeichnis P 3315 anzuzeigen Doppelklicken Sie auf P3315 EXE 2 Folgen Sie den Anweisungen auf Ihrem Bildschirm 3 Das Installationsprogramm erstellt ein Programmverzeichnis 28 8 3 PeakTech 3315 Interface Program starten Um das Interface Programm zu starten wie beschrieben verfahren 1 Das Messger t besitzt eine Infrarotschnittstelle mit der ein Anschluss an den PC ber USB m glich ist Stecken Sie das RS 232 C oder USB Schnittstellenkabel in die Vorrichtung auf der R ckseite des PeakTech 3315 und schlie en Sie das andere Ende an einen freien seriellen Anschluss an Ihrem Computer Schnittstellenkabel gt Z y gt TE J ou oss hy E K WA gt GK a ae INS Verbindung zum Computer lt Le RS 232 oder USB F Dr cken Sie die RS 232 Tas
6. Messung Eing nge und Messspitzen nicht ber hren ACHTUNG Entsprechende Abschnitte in der Bedienungsanleitung beachten ED W Doppelt isoliert Schutzklasse Il Q gt 4 lt Uberspannungskategorie Ill IV Wechselstrom Gleichstrom Gleich Wechselstrom Erdung Wia Batterie Symbol Ko H H Durchgangspr fung zh Diodentest 4 T Sicherung C Best tigt die Standards der Europ ischen Union 1 2 Maximal zul ssige Eingangswerte Messfunktion Eingangsbuchsen max zulassige Eingangs spannung bzw strom V DC 1000 V DC 750 V ACen V AC vaz com 1000 V DC 750 V ACer Q 600 V DC AC mA DC AC uA mA COM 1 A 250 V DC AC 10 A DC AC 10 A COM 10 A 250 V DC AC gt F 600 V DC ACss Frequenz p 600 V DC ACss Temperatur V O Hz COM 600V DC AC Kapazit t 600 V DC ACss 2 Allgemeines Das Multimeter ist universell einsetzbar handlich mit robustem Ge hause und ideal f r den Service Alltag von Technikern Es liefert unter normalen Bedingungen exakte Messergebnisse Uber ein Fol en Zeitraum von vielen Jahren gende Eigenschaften erleichtern die Arbeit mit diesem Gerat Messwert Haltefunktion DATA HOLD Minimal Maximalwert Haltefunktion Automatische Polaritatsumschaltung Relativwertmessung Uberlast und Uberspannungsschutz USB oder
7. RS 232 C Schnittstelle f r die Kommunikation mit einem PC Hintergrundbeleuchtung Batteriezustandsanzeige leuchtet im Anzeigefeld bei unzureichender Batterie spannung Summer A ert nt zur Warnung bei berlast bei Durchgangspr fungen und Bereichswahl Abschaltautomatik abschaltbar 2 1 Technische Daten Anzeige 3 stellige 25mm LCD Anzeige mit automatischer Polaritatsumschaltung max Anzeige 3999 Uberbereichsanzeige OL Messfolge 2 x pro Sekunde Abschaltautomatik nach 30 Minuten Betriebstemperatur 5 C 40 C bereich Lagertemperaturbereich 10 C 50 C Temperaturbereich f r 18 C 28 C lt 70 RH Genauigkeit Batteriezustandanzeige Batteriesymbol Spannungsversorgung 9V Batterie Abmessungen 90 B x 195 H x 39 T mm Gewicht 550g mitgel Zubeh r 1 Satz Pr fleitungen Batterie Temperaturf hler USB und RS 232 C Schnittstellenkabel und Software 7 3 Messfunktionen und bereiche 3 1 Gleichspannungsmessungen Bereich Aufl sung Genauigkeit berspannungs schutz 400 mV 100 uV 0 8 3 St 4 V 1 mV 1000 V DC 40 V 10 mV 0 8 1 St 750 V AC 400 V 100 mV 1000 V 1 V 1 3 St Eingangswiderstand 10MQ 3 2 Wechselspannungsmessungen Bereich Aufl sung Genauigkeit berspannungs schutz 4V 1mV 40 V 10 mV t1 5 St 1000 V DC 400 V 100 mV 750 V AC 750 V 1 V 1 2 5 St Eingangs
8. To leave the Hold Function press the Hold button again or move the Function switch If you are in the MAX MIN Function and you start the HOLD mode new peak values will not be reached Press the HOLD button again to enter the MAX MIN mode again Max MIN HOLD Function For measuring the MIN or Max value make the following steps Press the MIN MAX button to display the max measured value MAX Symbol appears in the LCD Press MAX MIN again to display the min measured value MIN Symbol appears in the LCD Press MAX MIN again to show the present measured value MAX MIN appears in the LCD R Press and hold the MAX MIN button for 1 second to leave the MIN MAX mode 10 Relative measurements Example If the stored Relative value is 20 00V and the present measured value is 22 00V the display shows a value of 2 00V lf the value is the same as the stored Relative value the display shows 0 00 V Press the REL button to activate the REL mode Auto range selection will be deactivated and the present range will be stored Press REL again to show the stored value 42 Press and hold the REL button for 1 second or turn the rotary switch to remove the stored value and to leave the REL mode 11 Switching on and off the computer connection 12 Backlight Press the button to activate the backlight It will be switched off automatically after 15 s
9. a local shop at no cost The disposal in domestic refuse is strictly forbidden according to the Battery Regulations You can return used batteries obtained from us at no charge at the address on the last side in this manual or by posting with sufficient stamps Batteries which contain harmful substances are marked with the symbol of a crossed out waste bin similar to the illustration shown left Under the waste bin symbol is the chemical symbol for the harmful substance e g Cd for cadmium Pb stands for lead and Hg for mercury 54 You can also find this notification in the paperwork accompanying the goods delivery or in the manufacturer s operating instructions You can obtain further information about the Battery Regulations from the Bundesministerium f r Umwelt Naturschutz und Reaktorsicherheit Federal Ministry of Environment Nature Conservation and Reactor Safety 7 2 Replacing the fuse WARNING To avoid electric shock disconnect the test leads before removing the battery or the fuse Replace only with the same type of battery or fuse Service should be performed only by qualified personnel Caution For continued protection against fire or other hazard replace only with a fuse of the specified voltage and current ratings F1 1A 250 V F 5x20 mm F2 10 A 250 V F 5x20 mm Follow these steps to replace the fuse 1 Turn off the meter and disconnect the test leads 2 Remove the cover
10. category IV 600V pollution degree 2 CAT I For signal level telecommunication electronic with small transient over voltage CAT Il For local level appliances main wall outlets portable equipment CAT Ill Supplied from a cable under earth fixed installed switches automatic cut off or main plugs CAT IV Units and installations which are supplied over aerial line which are stand in a risk of persuade of a lightning i e main switches on current input overvoltage diverter current use counter To ensure safe operation of the equipment and eliminate the danger of serious injury due to short circuits arcing the following safety precautions must be observed Damages resulting from failure to observe these safety precautions are exempt from any legal claims whatever Do not use this instrument for high energy industrial installation measurement Do not exceed the maximum permissible input ratings danger of serious injury and or destruction of the equipment The meter is designed to withstand the stated max voltages If it is not possible to exclude without that impulses transients disturbance or for other reasons these voltages are exceeded a suitable prescale 10 1 must be used Replace a defective fuse only with a fuse of the original rating Never short circuit fuse or fuse holding 31 Disconnect test leads or probe from the measuring circuit before switching modes or functions Do not conduct voltage
11. meter If you prop your meter on a bench top the stand helps provide a better viewing angle To use the stand as a prop just open it away from the meter and set it on a flat surface 6 How to make measurements Understanding Phantom readings In some DC and AC voltage ranges when the test leads are not connected to any circuit the display might show a phantom reading This is normal The meter s high input sensitivity produces a wandering effect When you connect the test leads to a circuit accurate reading appear 6 1 Measuring AC DC voltage WARNING Do not try to measure a voltage greater than 1000V DC or 750V AC You might damage your meter and expose yourself to a severe shock hazard 46 Follow these steps to measure DC AC Voltage 1 Set the rotary selector to the V position Select the range as required for the voltage level to be measured If you do not know the voltage level start with the range switch set to the highest voltage position and reduce the setting as needed to get a reading 2 Press m to select between DC and AC 3 Plug the black test lead into the meters COM terminal and the red test lead into the V Q Hz PH terminal 4 Connect the test leads to the DC AC voltage source you want to measure Warning When you connect the test probes to an AC outlet do not turn the rotary selector switch to another range It could damage the meter s internal components or injure you 6 2 M
12. um einen Nullabgleich der Anzeige durchzuf hren 5 Legen Sie die Pr fleitungen ber den zu messenden Kondensator 6 Messwert in der LCD Anzeige ablesen 6 8 Temperaturmessung Warnung Angeschlossene Pr fleitung nicht ber eine Spannungsquelle anlegen 1 Funktionswahlschalter in Stellung C bzw F stellen 23 2 Temperaturfthier ber die Eingangsbuchsen V Q Hz und COM anschlieBen 3 Messwert in der LCD Anzeige ablesen 7 Wartung des Ger tes 7 1 Auswechseln der Batterie Das Ger t erfordert eine 9V Blockbatterie Bei ungen gender Batteriespannung leuchtet das Batteriesymbol auf Die Batterie ist dann baldm glichst aus dem Batteriefach zu entfernen und durch eine neue Batterie zu ersetzen ACHTUNG Vor Abnahme des Geh uses unbedingt alle Pr fleitungen von der Schaltung entfernen und Ger t ausschalten 24 Zum Einsetzen der Batterie wie folgt verfahren 1 Ger t ausschalten und alle Pr fleitungen von der Mess schaltung bzw den Eing ngen des Multimeters abziehen 3 Schrauben am Geh usedeckel l sen und Geh use abnehmen Verbrauchte Batterie aus dem Batteriefach entfernen Neue Batterie in das Batteriefach einlegen Geh useboden wieder aufsetzen und mit 3 Schrauben befestigen Achtung Verbrauchte Batterien ordnungsgem entsorgen Verbrauchte Batterien sind Sonderm llund m ssen in die daf r vorgesehenen Sammelbeh lter gegeben werden Achtung Ger t nicht mit offe
13. Measure at REL mode 4 10 dot 40 nF 10 pF 400 nF 100 pF 600 Vpp 4 uF 1 nF 4 3 dgt 40 uF 10 nF 400 uF 100 nF 4 mF 1 uF 5 10 dgt 40 mF 10 uF 40mF range Reading is only for reference purpose 3 7 Diode Test Range Resolution Open circuit Overload voltage protection 4V 1mV 3V 600 Vp 3 8 Frequency Range Resolution Accuracy Overload protection 4 kHz 1 Hz 40 kHz 10 Hz 400 kHz 100 Hz 0 1 3 dgt 4 MHz 1 kHz 600 Vpp 40 MHz 10 kHz 400 MHz 100 kHz Input Sensitivity lt 40MHz lt 200MVims lt 100MHz 1Vims gt 100MHz Reference value only 39 3 9 Temperature Range Resolution Accuracy 40 C 40 C 0 C 3 4 dat 1000 C 1 C 0 C 400 C 1 3 dgt 400 C 1000 C 2 10 dat 40 F 40 F 32 F 3 4 dat 1832 F 1 F 32 F 752 F 1 4 dgt 752 F 1832 F 2 5 Overload protection 600V pp 3 10 Continuity Test Buzzer beeps continuously at less than 40Q Overload protection 600V pp 40 4 Front Panel Description 41 1 2 3 4 5 6 7 LCD Display Function switch COM terminal V Q Hz Diode terminal yA mA terminal 10 A terminal ON OFF button For switching the unit on or off 8 DATA HOLD button The Data Hold Function enables to freeze a measured value for later reading in the LCD For activating the Data Hold Function press the HOLD button H Symbol appears in the LCD
14. PeakTech Pr f und Messtechnik Spitzentechnologie die tiberzeugt oom _ PeakTech 3315 USB Bedienungsanleitung Operation manual Digital Multimeter 1 Sicherheitshinweise Dieses Ger t erf llt die EU Bestimmungen 2004 108 EG elektromagnetische Kompatibilit t und 2006 95 EG Nieder spannung entsprechend der Festlegung im Nachtrag 2004 22 EG CE Zeichen Uberspannungskategorie III 1000V Uberspannungs kategorie IV 600V Verschmutzungsgrad 2 CAT Signalebene Telekommunikation elektronische Ger te mit geringen transienten berspannungen CAT Il F r Hausger te Netzsteckdosen portable Instrumente etc CAT Ill Versorgung durch ein unterirdisches Kabel Fest installierte Schalter Sicherungsautomaten Steckdosen oder Sch tze CAT IV Ger te und Einrichtungen welche z B ber Frei leitungen versorgt werden und damit einer st rkeren Blitzbeeinflussung ausgesetzt sind Hierunter fallen z B Hauptschalter am Stromeingang berspannungs ableiter Stromverbrauchsz hler und Rundsteuer empf nger Zur Betriebssicherheit des Ger tes und zur Vermeidung von schweren Verletzungen durch Strom oder Spannungs berschl ge bzw Kurzschl sse sind nachfolgend aufgef hrte Sicherheitshinweise zum Betrieb des Ger tes unbedingt zu beachten Sch den die durch Nichtbeachtung dieser Hinweise entstehen sind von Anspr chen jeglicher Art ausgeschlossen Dieses Ger t darf nicht in hochenergetischen S
15. aste f r 1 Sekunde oder bet tigen Sie den Drehschalter um den gespeicherten Relativwert zur ckzusetzen und den REL Modus zu verlassen 11 Ein und Ausschalten der Computerverbindung 12 Hintergrundbeleuchtung Dr cken Sie die Taste um die Hintergrund beleuchtung einzuschalten Sie schaltet sich automatisch nach 15 Sek wieder aus 13 Taste Durchgangspr fung 14 Range Taste Bereichswahl Abschaltautomatik Die integrierte Abschaltautomatik des Ger tes schaltet das Ger t nach 30 Minuten ohne Bedienung ab um die Batterie zu schonen Diese Abschaltautomatik ist auch abschaltbar z B f r Dauermessungen mit der mitgelieferten Software Um die Abschaltautomatik zu deaktivieren gehen sie wie folgt vor Schalten Sie das Ger t ein und dr cken Sie gleichzeitig die MAX MIN Taste 4 1 Beschreibung 1 LCD Anzeige Die LCD Anzeige dient der digitalen Messwertanzeige mit automatischer Polarit tswahl und Kommaplatzierung Die maximale Anzeige betr gt 3999 Bei berschreitung der max Anzeigekapazit t von 3999 erscheint in der Digitalanzeige das berlaufsymbol OL 2 Funktions Bereichswahlschalter Zur Anwahl der gew nschten Messfunktion in die entsprech ende Stellung drehen 14 3 COM Eingang Zum Anschluss der schwarzen Pr fleitung alle Messfunktionen 4 VIOIHz F Eingang Zum Anschluss der roten Pr fleitung bei Spannungs Wider stands Kapazit ts und Frequenzme
16. backside and properly connect the other end of the cable to the serial or USB port of computer as show on following figure Interface cable FEN Pr Fa K KJ lt A A S S x Connection to computer SED RS 232 or USB 2 Press RS 232 button to activate the interface 3 Front the Windows START menu choose PROGRAMS gt P 3315 Interface Program gt P 3315 4 Press P3315 EXE to select corresponding COM 1 2 3 4 if using RS 232 C connection or press USB Connect from menu bar when using USB connection to start the connection between the computer and P 3315 5 When using USB connection it will automatically start 57 All rights also for translation reprinting and copy of this manual or parts are reserved Reproduction of all kinds photocopy microfilm or other only by written permission of the publisher This manual considers the latest technical knowing Technical changing which are in the interest of progress reserved We herewith confirm that the units are calibrated by the factory according to the specifications as per the technical specifications We recommend to calibrate the unit again after 1 year PeakTech 07 2012 th PeakTech Pr f und Messtechnik GmbH Kornkamp 32 DE 22926 Ahrensburg Germany Z 49 0 4102 42343 44 49 0 4102 434 16 H info peaktech de www peaktech de
17. berpr fen Im Zweifelsfale keine Messungen vornehmen Messarbeiten nur in trockener Kleidung und vorzugsweise in Gummischuhen bzw auf einer Isoliermatte durchf hren Messspitzen der Pr fleitungen nicht ber hren Warnhinweise am Ger t unbedingt beachten Bei unbekannten Messgr en vor der Messung auf den h chsten Messbereich umschalten Ger t keinen extremen Temperaturen direkter Sonneneinstrahlung extremer Luftfeuchtigkeit oder N sse aussetzen Starke Ersch tterung vermeiden Ger t nicht in der N he starker magnetischer Felder Motoren Transformatoren usw betreiben Hei e L tpistolen aus der unmittelbaren N he des Ger tes fernhalten Vor Aufnahme des Messbetriebes sollte das Gerat auf die Umgebungstemperatur stabilisiert sein wichtig beim Transport von kalten in warme Raume und umgekehrt berschreiten Sie bei keiner Messung den eingestellten Messbereich Sie vermeiden so Besch digungen des Ger tes Drehen Sie w hrend einer Strom oder Spannungsmessung niemals am Messbereichswahlschalter da hierdurch das Ger t besch digt wird Messungen von Spannungen ber 35V DC oder 25V AC nur in bereinstimmung mit den relevanten Sicherheits bestimmungen vornehmen Bei h heren Spannungen k nnen besonders gef hrliche Stromschl ge auftreten Ersetzen Sie die Batterie sobald das Batteriesymbol BAT aufleuchtet Mangelnde Batterieleistung kann unpr zise Messergebnisse hervorrufen Stromschl ge und k rpe
18. by unscrewing the 3 screws and pulling off the meter s cover 3 Install the new fuse in the fuse compartment 4 Replace the cover and secure it with the screws 55 8 Connecting the meter to a PC 8 1 System requirements To use the Interface Program you need the following hard and software An IBM PC or equivalent computer Microsoft Windows 2000 XP Vista 7 At least 512 MB of RAM At least 8 MB free space in hard drive A free serial or USB port 8 2 Installing PeakTech 3315 Interface Software To install the Interface Program please follow below procedure 1 Insert the provided CD ROM into CD ROM drive Double click the MY COMPUTER icon on the Windows Desktop Locate the CD ROM drive from the windows double click the drive letter to display the folder of P 3315 Double click P 3315 to display the contents of the folder Double click the file P3315 EXE 2 Follow the on screen installation instructions 3 The installation program will create a PeakTech 3315 folder You will be prompted to select the kind of Program Folder you want to install you should select PeakTech 3315 Interface Program 56 8 3 Getting started with PeakTech 3315 Interface Program To run the Interface Program please do the following 1 The meter had infrared interface which allows to connect to PC via USB or RS 232 C Insert the supplied Interface cable into the slot at the meter s
19. chaltungen verwendet werden Maximal zul ssige Eingangsspannung von 1000V DC oder 750 V AC unter keinen Umst nden berschreiten schwere Verletzungsgefahr und oder Zerst rung des Ger tes Die angegebenen maximalen Eingangsspannungen d rfen nicht berschritten werden Falls nicht zweifelsfrei ausgeschlossen werden kann dass diese Spannungsspitzen durch den Einfluss von transienten St rungen oder aus 1 anderen Gr nden berschritten werden muss die Messspannung entsprechend 10 1 vorged mpft werden Nehmen Sie das Ger t nie in Betrieb wenn es nicht v llig geschlossen ist Defekte Sicherungen nur mit einer dem Originalwert entsprechenden Sicherung ersetzen Sicherung oder Sicherungshalter niemals kurzschlie en Vor dem Umschalten auf eine andere Messfunktion Pr f leitungen oder Tastkopf von der Messschaltung abkoppeln Keine Spannungsquellen ber die mA A und COM Eing nge anlegen Bei Nichtbeachtung droht Verletzungsgefahr und oder die Gefahr der Besch digung des Multimeters Der 10A Bereich ist durch eine Sicherung abgesichert Strommessungen nur an Ger ten mit entsprechender Absicherung durch Sicherungsautomaten oder Sicherungen 10A oder 2000VA vornehmen Bei der Widerstandsmessungen keine Spannungen anlegen Keine Strommessungen im Spannungsbereich V Q vornehmen Ger t Pr fleitungen und sonstiges Zubeh r vor Inbetriebnahme auf eventuelle Sch den bzw blanke oder geknickte Kabel und Dr hte
20. d Hg f r Quecksilber Sie finden diese Hinweise auch noch einmal in den Begleitpapieren der Warensendung oder in der Bedienungsanleitung des Herstellers Weitere Hinweise zur Batterieverordnung finden Sie beim Bundesministerium f r Umwelt Naturschutz und Reaktorsicherheit 26 7 2 Auswechseln der Sicherung ACHTUNG Vor Abnahme der R ckwand zum Auswechseln der Sicherung Multimeter ausschalten und alle Pr fleitungen von den Eing ngen abziehen Defekte Sicherung nur mit einer dem Originalwert u aomessungen entsprechenden Sicherung ersetzen Fi 1A 250V F 5x20 mm Glassicherung F2 10A 250 V F 5 x 20 mm Glassicherung Die Abnahme der R ckwand und das Auswechseln der Sicherungen darf nur durch qualifiziertes Fachpersonal erfolgen Zum Auswechseln der Sicherung wie folgt verfahren 1 Multimeter ausschalten und alle Pr fleitungen von den Eing ngen abziehen 2 Die 3 Schrauben im Geh useunterteil l sen und Unterteil abziehen 3 Defekte Sicherung entfernen und neue Sicherung gleichen Anschlusswertes und Abmessungen in den Sicherungshalter einsetzen Beim Einsetzen darauf achten dass die Sicherung mittig im Sicherungshalter zu liegen kommt 4 Unterteil wieder auflegen und mit den 3 Schrauben befesti gen Keine Messungen bei abgenommenen Geh use vornehmen 27 8 Betrieb des Ger tes an einem PC 8 1 Systemvoraussetzungen zum Betrieb des PeakTech 3315 Interface Program Um mit dem
21. ds messfunktion angeschlossene Pr fleitung nicht ber eine Spannungsquelle anlegen Widerstandsmessungen nur an spannungsfreien Schaltungen bzw Bauteilen vornehmen und alle Kondensatoren entladen Mit dem Funktions Bereichswahlschalter die Q Position w hlen Rote Prifleitung an den ViO Hzi P Eingang und schwarze Pr fleitung an den COM Eingang anschlie en Pr fleitungen ber die zu messende Schaltung bzw das zu messende Bauteil anlegen weise Bei berschreitung des Messbereiches leuchtet in der LCD Anzeige das Uberlaufsymbol OL auf Der Eigenwiderstand der Pr fleitungen kann bei Messungen von kleinen Widerst nden 400 Q Bereich die Genauigkeit der Messung negativ beeintr chtigen Der Eigenwiderstand blicher 20 Prifleitungen liegt zwischen 0 2 1 Q Zur genauen Bestimmung des Eigenwiderstandes Pr fleitungen an die Eingangsbuchsen des Multimeters anschlie en und Mess spitzen kurzschlie en Der angezeigte Messwert entspricht dem Eigenwiderstand der Pr fleitungen Bei Widerstandsmessungen von 1MQ und h her ben tigt die Anzeige einige Sekunden zur Stabilisierung 6 4 Diodentest WARNUNG Nach Umschaltung des Multimeters auf die Diodentestfunktion angeschlossene Pr fleitungen nicht ber eine Spannungsquelle anlegen Diese Funktion erm glicht die berpr fung von Dioden und anderen Halbleitern auf Durchl ssigkeit und Kurzschl sse Ebenfalls erlaubt diese Funktion die Durchlassspan
22. e certain limits For proper operation replace the battery as soon as possible Continued use with a low battery will lead to abnormal readings Warning To avoid electric shock disconnect both test leads from equipment before you remove or install the Q Follow these steps to install the battery 1 Turn off the power and disconnect the two test leads 2 Remove the 3 screw to open the back cover 3 Remove the battery 4 Place the battery into the insulation capsule 5 Replace the back cover and secure it with the screws 53 WARNING Do not operate the meter until you replace the battery and close the battery compartment cover Notes Never leave a weak or dead battery in your meter Even a leakproof battery can leak damaging chemicals When you are not going to use your meter for a week or more remove the battery Batteries which are used up dispose duly Used up batteries are hazardous and must be given in the for this being supposed collective container Statutory Notification about the Battery Regulations The delivery of many devices includes batteries which for example serve to operate the remote control There also could be batteries or accumulators built into the device itself In connection with the sale of these batteries or accumulators we are obliged under the Battery Regulations to notify our customers of the following Please dispose of old batteries at a council collection point or return them to
23. easuring DC AC Current WARNINGS Do not apply voltage directly across the terminals You must connect the meter in series with the circuit The 10A terminal is fused A severe fire hazard and short circuit danger exists if you apply a voltage with high current capability to this terminal The meter can be destroyed under such conditions To measure current break the circuit and connect the probes to two circuit connection points Never connect the probes across a voltage source in parallel Doing so can blow the fuse or damage the circuit under test Note The maximum input current is 400uA 400mA or 10A depending on the terminal used In these ranges excessive current blows the fuses which you must replace 47 1 Set the rotary selector to the uA mA range If you do not know the current level set it to the highest position and reduce the setting as needed to get a reading 2 Press to select between DC and AC 3 Plug the black test lead into your meter s COM terminal and the red test lead into your meter s uA mA or 10A terminal 4 Remove power from the circuit under test and then break the circuit at the appropriate point 5 Connect the test leads in series with the circuit 6 Apply power and read the current Your meter displays the current value Note If you see the meter for DC current appears or disappears This indicates the polarity of the measured current 6 3 Measuring Resistance
24. econds 13 button Continuity test 14 Range button for range selection Auto Power Off To prevent battery life the meter automatically turns off if you do not turn the rotary switch or press any button for 30 minutes The buzzer beeps before turning off The meter can be activated by turning the rotary switch or pressing any button it will display the last measurement value before entering auto power off To disable the auto power off function press any one of the MIN MAX RANGE REL or RS232C buttons while turning on the meter 4 1 Description 1 Digital Display Digital readings are displayed on a 3999 count display with automatic polarity indication and decimal point placement 2 Function selector To select the measuring range 3 COM Common Terminal Return terminal for all measurements 4 Voz PE Continuity Diode Ohms Volt Frequency capacitance and regulation terminal 5 uA mA Input terminal For current measurements up to 400mA DC AC when the rotary selector is in the pA mA position 43 6 10 A Input Terminal For current measurements AC or DC up to 10A when the rotary selector switch is in the 10A position 7 Data Hold function The data hold feature lets you hold a reading on the display To turn on the data hold feature press HOLD until HOLD appears on the display 8 Backlight The backlight helps to read measuring values from the display at unfavourable l
25. einer entsprechenden Sicherung abgesichert Bei Anschluss einer Spannungsquelle an diesen Eingang besteht Verletzungsgefahr und die Gefahr der Zerst rung des Ger tes Zur Durchf hrung von Strommessungen zu messende Schaltung unterbrechen und Pr fleitungen an zwei Anschlusspunkte anlegen Niemals die Pr fleitungen parallel ber eine Spannungsquelle anlegen Dies kann zu einem Ansprechen der Sicherung und Zerst rung der zu pr fenden Schaltung f hren Hinweis Der maximale Eingangsstrom betr gt 4000uA 400mA und 10A abh ngig von der benutzen Eingangsbuchse Bei berschreiten des maximal zul ssigen Wertes spricht die Sicherung an und muss ausgewechselt werden 1 Erforderlichen Messbereich mit dem Funktions Bereichs wahlschalter w hlen Bei ungekanntem Messwert aus Sicherheitsgr nden Pr fleitungen an den 10 A Eingang anschlie en und Funktions Bereichswahlschalter in Stellung 10A drehen Bei entsprechender Anzeige ggf auf einen niedrigeren Messbereich umschalten 19 Hin Bei Zum Umschalten zwischen DC und AC Taste dr cken Rote Pr fleitung an uA mA bzw 10 A Buchse und schwarze Pr fleitung an COM Buchse anschlie en Prifleitungen in Reihe zur Messschaltung anschlieBen und Messwert in der LCD Anzeige ablesen weis Gleichstrommessungen zeigt das Symbol vor dem Messwert einen negativen Wert an 6 3 Widerstandsmessungen Warnung Hin Nach Umschaltung des Multimeters auf die Widerstan
26. ighting conditions 9 ON OFF button To switch on or off the unit 11 button To select between AC or DC measurements 12 Range button For manual selection of measuring range 4 2 Display Symbole 12 J 10 15 FR 11177777772 7999 aoier A M symbols 44 The meter is in the auto range mode in which the meter automatically selects the range with the best resolution Low battery indicator Polarity indicator Diode test Continuity test Relative Mode Data Hold Indicator for DC voltage or current Indicator for AC voltage or current The display value is the mean value Symbols for resistance frequency voltage current capacitance and temperature Analogue Bar Graph OL Overload indication computer connection Auto power off 45 5 Preparation for Operation 5 1 Using the test leads Use only the identical type of test leads supplied with your meter These test leads are rated for 1000V Cautions The maximum rating of your meter is 1000V DC and 750V AC If you try to measure DC voltages above 1000V or AC voltages 750Vims you might damage your meter and expose yourself to a serious shock hazard Use extreme care when you measure high voltages Never connect the probe you plug into the COM terminal to a source of voltage greater than 1000V DC AC with respect to earth ground This creates a serious shock hazard 5 2 Using the stand Use your meter s stand to prop up the
27. lets you determine the forward voltage for diodes You can use this function when you need to match diodes 1 Set the rotary selector to the position 2 Plug the black test lead into your meter s COM terminal and the red test lead into your meter s V Q Hz I1 terminal 3 Connect the test leads to the diode you want to check and note the meter reading Notes If the display shows a value for example 0 2 for a germanium diode or 0 5 for a silicon diode reverse the diode If the meter indicates and overrange the diode is good The displayed number is the diode s actual forward voltage up to 2 0 volts 49 If the display indicates an overrange condition reverse the polarity of the connection If the display shows a value the device is good The displayed value is the component s actual forward voltage up to 2 0 volts If the display still indicates anoverrange condition the device is open If the display shows a value both before and after you reverse the polarity the device is shorted When you connect the diode to the meter and the meter displays the devices forward voltage the red test lead is connect to the diods s anode and the black test lead is connected to the diode s cathode This meter supplies enough forward voltage to light most LED s However if the LED s forward voltage is greater than 2 0 volts the meter incorrectly indicates that the device is open 6 5 Checking Continuity Fol
28. low these steps to check a circuit s continuity 1 Set the rotary selector to 0 2 Plug the black test lead into your meter s COM terminal and the red test lead into your meter s V Q Hz terminal 3 Press to switch between Q and 4 Remove power from the circuit 5 Connect the test leads to the circuit Note The buzzer sounds if the measured resistance is below about 40Q approximately Warning Never perform a continuity measurement on a circuit that has power connected 50 6 6 Measuring Frequency Warning If you try to measure the frequency of a signal that exceeds 600V ACms you might damage your meter and expose yourself to a severe shock hazard Follow these steps to measure the frequency of a signal 1 Set the rotary selector to Hz 2 Plug the black test lead into your meter s COM terminal and the red test lead into you meter s V O Hz H terminal 3 Connect the test leads to the frequency source Warning When you connect the test leads to an AC outlet do not turn the function rotary selector to another range It could damage the meter s internal components or injure you Note For the most accurate measurements we strongly recommend you to use a BNC cable with ferrite core 6 7 Capacitance measurements WARNING To avoid electric shock disconnect power to the unit under test and discharge all capacitors before taking any capacitance measurements Remove the batte
29. mbol in der LCD Um die Hold Funktion zu verlassen dr cken Sie die Taste Hold erneut oder drehen Sie den Funktionswahlschalter Wenn Sie sich in der MAX MIN Funktion befinden und Sie den HOLD Modus starten werden keine neuen Spitzenwerte aufgenommen Dr cken Sie die HOLD Taste erneut um wieder in den MAX MIN Modus zugelangen Maximal und Minimalwerthaltefunktion Zum Ermitteln des maximalen bzw des minimalen Messwertes wie beschrieben verfahren Dr cken Sie die Taste MIN MAX um den maximalen Messwert anzugeigen MAX Symbol erscheint in der Anzeige Dr cken Sie MAX MIN erneut um minimalen Messwert anzuzeigen MIN Symbol erscheint in der Anzeige Dr cken Sie MAX MIN erneut um den momentanen Messwert anzuzeigen MAX MIN erscheint in der Anzeige Dr cken und halten Sie die Taste MAX MIN f r 1 Sekunde um den MAX MIN Modus zu verlassen 10 Relativwertmessfunktion Beispiel Wenn der gespeicherte Relativwert 20 00V ist und der aktuell gemessene Wert 22 00V zeigt die Anzeige einen Wert von 2 00V an Ist eine erneute Messung identisch mit dem Relativwert zeigt die Anzeige 0 00V an 13 Dr cken Sie die Taste REL um den Relativ Modus zu aktivieren Die automatische Bereichswahl wird deaktiviert und der momentane Messbereich wird eingestellt und gehalten Dr cken Sie REL erneut um den gespeicherten Wert anzuzeigen Dr cken und halten Sie die REL T
30. measurements with the test leads connected to the mA A and COM terminal of the equipment The 10 A range is protected To avoid damage or injury use the meter only in circuits limited by fuse or circuit breaker to 10 A or 2000VA To avoid electric shock disconnect power to the unit under test and discharge all capacitors before taking any resistance measurements Do not conduct current measurements with the leads connected to the V Q terminals of the equipment Check test leads and probes for faulty insulation or bare wires before connection to the equipment To avoid electric shock do not operate this product in wet or damp conditions Conduct measuring works only in dry clothing and rubber shoes i e on isolating mats Never touch the tips of the test leads or probe Comply with the warning labels and other info on the equipment Always start with the highest measuring range when measuring unknown values Do not subject the equipment to direct sunlight or extreme temperatures humidity or dampness Do not subject the equipment to shocks or strong vibrations Do not operate the equipment near strong magnetic fields motors transformers etc Keep hot soldering irons or guns away from the equipment Allow the equipment to stabilize at room temperature before taking up measurement important for exact measurements Do not input values over the maximum range of each measurement to avoid damages of the meter Do not turn the ro
31. nect the probes Min Max function Auto polarity operation Relative measurement Overload and Transient protection RS 232 C or USB interface for communication to the PC Backlight Low Battery indicator appears when you need to replace the batteries Beeper sounds for overload warning continuity function and range selection Auto power off able to switch off 35 2 1 General Characteristics Display Overrange indication Reading time Auto power off Operating temperature Storage temperature Temperature for guaranteed accuracy Low battery indication Battery Type Dimensions Weight Accessories 3 digit 25 mm LCD display max indication 3999 with automatic polarity indication OL 2 reading per second after 30 minutes 5 C 440 C 41 F 104 F 10 C 50 C 14 F 122 F 18 C 28 C lt 70 RH Battery symbol Standard 9V battery 90 W x 195 H x 39 D mm 550g Test leads operating manual battery thermocouple RS 232 C and USB interface cable software 36 3 Functions and Ranges 3 1 DC voltage measurement Range Resolution Accuracy Overload protection 400 mV 100 pV 0 8 3 dgt 4 V 1 mV 1000 V DC 40 V 10 mV 0 8 1 dgt 750 V AC 400 V 100 mV 1000 V 1 V 1 3 dgt Input impedance 10 MQ 3 2 AC voltage measurement Range Resolution Accuracy Overload protection 4V 1 mV 40 V
32. nem Batteriefach benutzen Hinweis Niemals eine defekte oder verbrauchte Batterie im Messger t belassen Auch auslaufsichere Batterien k nnen Besch digungen durch auslaufende Batteriechemikalien verursachen Ebenso sollte bei l ngerem Nichtgebrauch des Ger tes die Batterie aus dem Batteriefach entfernt werden 25 Gesetzlich vorgeschriebene Hinweise zur Batterieverordnung Im Lieferumfang vieler Gerate befinden sich Batterien die z B zum Betrieb von Fernbedienungen dienen Auch in den Ger ten selbst k nnen Batterien oder Akkus fest eingebaut sein Im Zusammenhang mit dem Vertrieb dieser Batterien oder Akkus sind wir als Importeur gem Batterieverordnung verpflichtet unsere Kunden auf folgendes hinzuweisen Bitte entsorgen Sie Altbatterien wie vom Gesetzgeber vorgeschrieben die Entsorgung im Hausm ll ist laut Batterieverordnung ausdr cklich verboten an einer kommunalen Sammelstelle oder geben Sie sie im Handel vor Ort kostenlos ab Von uns erhaltene Batterien k nnen Sie nach Gebrauch bei uns unter der auf der letzten Seite angegeben Adresse unentgeltlich zur ckgeben oder ausreichend frankiert per Post an uns zur cksenden Batterien die Schadstoffe enthalten sind mit dem Symbol einer durchgekreuzten M lltonne gekennzeichnet hnlich dem Symbol in der Abbildung links Unter dem M lltonnensymbol befindet sich die chemische Bezeichnung des Schadstoffes z B CD f r Cadmium Pb steht f r Blei un
33. nung von Dioden zu ermitteln 1 Funktions Bereichswahlschalter in Stellung PL drehen 2 Rote Prifleitung an den V Q Hz gt Eingang und schwarze Pr fleitung an den COM Eingang anschlie en 3 Pr fleitungen ber die zu pr fende Diode anlegen und Messwert in der LCD Anzeige ablesen Hinweise Wenn in der LCD Anzeige ein Messwert angezeigt wird z B 0 2 bei einer Germaniumdiode oder 0 5 bei einer Siliziumdiode Polung der Pr fleitungen ndern Wird berlauf angezeigt ist die Diode durchg ngig und in Ordnung Der angezeigte Wert entspricht dem Durchlass widerstand des Bauteils bis zu 2 0V Bei berlaufanzeige im Display ist die Diode defekt oder die Pr fleitungen sind falsch gepolt Wird in der Anzeige 21 ein Wert angezeigt ist die Diode durchg ngig und in Ordnung Der angezeigte Wert entspricht dem Durchlass widerstand des Bauteils bis zu 2 0V Wird ein Wert sowohl vor als auch nach dem Vertauschen der Polarit t angezeigt ist das Bauteil kurzgeschlossen und defekt 6 5 Durchgangspr fung 1 Funktions Bereichswahlschalter in Stellung 2 drehen 2 Die Taste dient zur Umschaltung zwischen Q und gt 3 Rote Pr fleitung an den V a Hz P Eingang und schwarze Pr fleitung an den COM Eingang des Ger tes anschlie en 4 Zu messende Schaltung spannungslos schalten 5 Pr fleitungen ber das zu messende Bauteil bzw die zu messende Schaltung anlegen Bei Widerst nden un
34. r Anzeige ist in der hohen Empfindlichkeit des Ger tes begr ndet Ein Kurzschlie en der Messkabel Eing nge hebt diesen Effekt auf und die Anzeige zeigt 000 bzw bei Anschluss der Messleitungen wird der richtige Messwert angezeigt WARNUNG Maximal zul ssige Eingangsspannung von 1000V DC oder 750V AC nicht berschreiten Bei berschreitung besteht die Gefahr schwerer Verletzungen durch Stromschlag und oder die Gefahr der Besch digung des Ger tes 1 Funktions Bereichswahlschalter in die f r Gleich oder Wechselspannungsmessung erforderliche Stellung drehen V Bei unbekannten Messwerten mit dem h chsten Messbereich beginnen und ggf auf einen niedrigeren Bereich herunterschalten ___ 2 Mit der Taste ggf zwischen AC und DC umschalten 3 Rote Pr fletung an den V Q H2 P Eingang und schwarze Pr fleitung an den COM Eingang anschlie en 4 Pr fleitungen ber die zu messende Schaltung bzw das zu messende Bauteil anlegen 18 Warnung Wenn die Prifleitungen an eine Netzsteckdose angelegt werden auf keinen Fall den Funktions Bereichswahlschalter auf einen anderen Messbereich einstellen Dies k nnte zur Zerst rung der internen Schaltung des Ger tes und schweren Verletzungen f hren 6 2 Gleich und Wechselstrommessungen Warnung Keine Spannung direkt ber die Anschl sse legen Das Ger t darf nur in Reihe mit der zu messenden Schaltung angeschlossen sein Der 10 A Eingang ist mit
35. ries and unplug the line cords 1 Set the function switch to the J F position 2 Plug the black test lead into yours meter s COM terminal and the red test lead into your meter s V Q Hz Pt terminal 3 Set the RANGE button to the correct measuring range 4 Press the REL button to bring the display to zero 5 Touch the test leads to the capacitor to be tested The display will indicate the proper decimal point value 51 6 8 Temperature measurements Warning To avoid electric shock disconnect both test probes from any source of voltage before making a temperature measurement 1 If you wish to measure temperature in F set the function switch to the F range If you wish to measure temperature in C set the function switch to the C range 2 Insert the temperature probe into the V Q Hz t terminal and COM terminal 3 Touch the Temperature probe head to the part whose temperature you wish to measure Keep the probe touching the part under test until the reading stabilizes about 30 seconds 4 Read the temperature in the display The digital reading will indicate the proper decimal point and value Warning To avoid electric shock be sure that the thermocouple has been removed before changing to another measurement function 52 7 Care and Maintenance 7 1 Installing the battery Your meter requires a 9 V battery for power The battery symbol appears when the battery voltage drops to th
36. rliche Sch den k nnen die Folge sein Sollten Sie das Ger t f r einen l ngeren Zeitraum nicht benutzen entnehmen Sie die Batterie aus dem Batteriefach S ubern Sie das Geh use regelm ig mit einem feuchten Stofftuch und einem milden Reinigungsmittel Benutzen Sie keine tzenden Scheuermittel Dieses Ger t ist ausschlie lich f r Innenanwendungen geeignet Vermeiden Sie jegliche N he zu explosiven und entflammbaren Stoffen ffnen des Ger tes und Wartungs und Reparaturarbeiten d rfen nur von qualifizierten Service Technikern durchgef hrt werden Ger t nicht mit der Vorderseite auf die Werkbank oder Arbeitsfl che legen um Besch digung der Bedienelemente zu vermeiden Keine technischen Ver nderungen am Ger t vornehmen Messger te geh ren nicht in Kinderh nde 1 1 Am Ger t befindliche Hinweise und Symbole 10A Abgesicherter Eingang f r Strommessungen im A Bereich bis max 10A AC DC Im 10A Bereich Messvorgang auf max 30 Sek begrenzen n chste Messung erst nach 15 Minuten vor nehmen Der Eingang ist mit einer Sicherung 10A 250V abgesichert 3 gt Eingang f r Strommessungen bis max 400mA AC DC Der Eingang ist mit einer Sicherung 1 A 250 V abgesichert 3 D x max zul ssige Spannungsdifferenz von 1000V DC AC zwischen COM Eingang und Erde aus Sicherheitsgr nden nicht berschreiten Gef hrlich hohe Spannung zwischen den Eing ngen Extreme Vorsicht bei der
37. rom Kapazitats und Temperaturmessung 11 Analoge Baltengrafik 12 Polaritatsanzeige der Balkengrafik 13 OL Uberlaufanzeige 14 Computerverbindung 15 Abschaltautomatik 5 Vorbereitung zur Inbetriebnahme 5 1 Anschluss der Pr fleitungen Die dem Ger t beiliegenden Pr fleitungen sind f r Messungen bis maximal 1000V geeignet Das Messen von hohen Spannungen sollte nur mit u erster Vorsicht und nur in Anwesenheit einer in Erster Hilfe ausgebildeten Person stattfinden Achtung Die maximal zul ssige Eingangsspannung des Ger tes betr gt 1000V DC oder 750V AC und darf aus Sicherheitsgr nden nicht berschritten werden Die maximal zul ssige Spannungsdifferenz zwischen dem COM Eingang und Erde betr gt 1000V DC AC Bei gr eren Spannungsdifferenzen besteht Verletzungsgefahr durch elektrischen Schlag und oder die Gefahr der Besch digung des Messger tes 5 2 Universal Aufstellb gel Das Ger t ist zur Schr gstellung auf einem Arbeitstisch mit einem Standb gel an der R ckseite versehen Zum Schr gstellen Standb gel am unteren Ende greifen und nach au en ziehen 17 6 Messbetrieb 6 1 Gleich und Wechselspannungsmessungen Phantomwerte In niedrigen DC und AC Spannungsbereichen und nicht angeschlossenen und somit offenen Eingangen zeigt die LCD Anzeige sogenannte Phantomwerte d h nicht 000 an Dieses ist normal und stellt keinen Defekt des Ger tes dar Dieser wandernde Effekt de
38. ssungen sowie f r die Messfunktionen Diodentest Durchgangspr fungen 5 HA mA Eingang Zum Anschluss der roten Pr fleitung bei AC DC Strommes sungen im uA mA Bereich bis max 400mA _ Funktions Bereichswahlschalter in Stellung uA mA 6 10 A Eingang Zum Anschluss der roten Prifleitung bei AC DC Strommessungen bis max 10A _ Funktions Bereichs wahlschalter in Stellung 10A 7 Data Hold Funktion Die Data Hold Funktion erm glicht das Einfrieren eines Messwertes zum sp teren Ablesen in der LCD Zur Aktivierung der Data Hold Funktion HOLD Taste dr cken bis das Symbol HOLD im Anzeigefeld erscheint 8 Hintergrundbeleuchtung Die Hintergrundbeleuchtung dient zum besseren Ablesen des Messwertes bei ung nstigen Lichtverh ltnissen 9 Ein Aus Taste Zum Ein und Ausschalten des Ger tes 10 Taste Zum Umschalten zwischen Messfunktionen DC und AC sowie Q und 11 Bereichswahl Taste Zum manuellen Ausw hlen des Messbereiches 15 4 2 Display Symbole 10 alle anderen Das Gerat befindet sich im Auto Bereichswahl Modus in dem automatisch der richtige Bereich und die beste Aufl sung gew hlt wird Batteriezustandsanzeige Polarit tsanzeige Diodentestfunktion Durchgangspr fung Relativwert Messung Data Hold Anzeige f r Gleichspannung oder strom Anzeige f r Wechselspannung oder strom 16 10 Messsymbol f r Widerstands Frequenz Spannungs St
39. tary function switch during voltage or current measurement otherwise the meter could be damaged Use caution when working with voltages above 35V DC or 25V AC These Voltages pose shock hazard Replace the battery as soon as the battery indicator BAT appears With a low battery the meter might produce false reading that can lead to electric shock and personal injury 32 Fetch out the battery when the meter will not be used for long period Periodically wipe the cabinet with a damp cloth and mid detergent Do not use abrasives or solvents The meter is suitable for indoor use only Do not operate the meter before the cabinet has been closed and screwed safely as terminal can carry voltage Do not store the meter in a place of explosive inflammable substances Do not modify the meter in any way Opening the equipment and service and repair work must only be performed by qualified service personnel Measuring instruments don t belong to children hands 1 1 Safety Symbols The following symbols are imprinted on the front panel of the meter to remind you of measurement limitations and safety The maximum current that you can measure a this terminal is 10A DC AC This terminal is fuse protected 10A by F 10 A 250V fuse When using this range with high current keep the duty cycle to 30 seconds on load and 15 minutes off load The max current that you can measure with this HA mA terminal is 400 mA
40. te zum Aktivieren der Schnittstelle Klicken Sie auf die Schaltfl che START und ffnen Sie Ihr Windows Startmen w hlen Sie Programme P 3315 Interface Program gt P 3315 Klicken Sie auf P3315 EXE in der Men leiste der Software und w hlen Sie zwischen COM 1 2 3 4 wenn Sie eine RS 232C Verbindung verwenden oder dr cken Sie USB Connect wenn Sie eine USB Verbindung verwenden um die Verbindung zwischen Computer und Ger t zu starten Bei Verwendung einer USB Verbindung wird diese automatisch gestartet 29 Alle Rechte auch die der Ubersetzung des Nachdruckes und der Vervielfaltigung dieser Anleitung oder Teilen daraus vorbehalten Reproduktionen jeder Art Fotokopie Mikrofilm oder ein anderes Verfahren nur mit schriftlicher Genehmigung des Herausgebers gestattet A Letzter Stand bei Drucklegung Technische Anderungen des Ger tes welche dem Fortschritt dienen vorbehalten Hiermit bestatigen wir dass alle Ger te die in unseren Unterlagen genannten Spezifikationen erf llen und werkseitig kalibriert geliefert werden Eine Wiederholung der Kalibrierung nach Ablauf von 1 Jahr wird empfohlen PeakTech 07 2012 th 30 1 Safety Precautions This product complies with the requirements of the following European Community Directives 2004 108 EC Electromagnetic Compatibility and 2006 95 EC Low Voltage as amended by 2004 22 CE CE Marking Overvoltage category Ill 1000V overvoltage
41. ter 40 Q Bauteil durchg ngig ert nt ein akustisches Signal ACHTUNG Unter keinen Umst nden Durchgangspr fungen an spannungs f hrenden Bauteilen oder Schaltungen vornehmen 6 6 Frequenzmessung Warnung Keine Messungen an Schaltungen mit Spannungen ber 600V AC durchf hren Bei berschreitung dieses Spannungswertes besteht die Gefahr schwerer Verletzungen durch Stromschlag und oder die Gefahr der Besch digung des Ger tes 1 Funktions Bereichswahlschalter in die Hz Stellung drehen drehen 2 Rote Pr fleitung an den V Q Hz gt Eingang und schwarze Pr fleitung an den COM Eingang anschlieBen 22 3 Pr fleitung Uber die zu messende Schaltung bzw das zu messende Bauteil anlegen und Frequenz in der LCD An zeige ablesen F r genaue Frequenzmessungen wird eine Messleitung mit BNC Anschl ssen empfohlen WARNUNG Bei Messungen an Netzsteckdosen Stellung des Funktions wahlschalters nicht ver ndern Es besteht sonst Verletzungsgefahr und oder die Gefahr der Besch digung des Ger tes 6 7 Kapazit tsmessungen Warnung Angeschlossene Pr fleitungen nicht ber eine Spannungsquelle anlegen Kondensatoren vor der Messung immer entladen 1 Funktionsbereichswahlschalter in Stellung 4 F drehen 2 Rote Pr fletung an den V 2 H2 gt Eingang und schwarze Pr fleitung an den COM Eingang anschlie en 3 W hlen Sie mit der Range Taste den gew nschten Mess bereich 4 Dr cken Sie die REL Taste
42. widerstand 10MQ Zeigt den effektiven Wert der Sinuswelle an Frequenz 40Hz 400Hz 3 3 Gleichstrommessungen Bereich Aufl sung Genauigkeit berspannungs schutz 400 uA 100 nA 1 2 St 1 A 250 V 4000 uA 1 uA 40 mA 10 pA 1 2 3 St 400 mA 100 pA 10 A 10 mA 1 5 5 St 10 A 250 V 10A Bereich F r dauerhafte Messungen lt 10 Sekunden und Intervall Messungen nicht weniger als 15 Minuten 3 4 Wechselstrommessungen Bereich Aufl sung Genauigkeit berspannungs schutz 400 pA 100 nA 1 5 5St 1 A 250 V 4000 uA 1 uA 40 mA 10 pA 2 5 St 400 mA 100 uA 10 A 10 mA 2 5 5 St 10 A 250 V 400uA 400mA Bereich Zeigt den effektiven Wert der Sinuswelle an 10A Bereich F r dauerhafte Messungen lt 10 Sekunden und Intervall Messungen nicht weniger als 15 Minuten Frequenz 40Hz 400Hz 3 5 Widerstandsmessun Bereich Aufl sung Genauigkeit berspannungs schutz 40 Q 0 12 1 2 2 St 4 kQ 1 Q 40 kQ 10 Q 1 2 St 400 kQ 100 Q 4MQ 1kQ 1 2 2 St 600 Vss 40 MQ 10 kQ 1 5 2 St 400 Q 40 MQ Bereich Leerlaufspannung ca 3 V 3 6 Kapazitatsmessungen Bereich Aufl sung Genauigkeit berspannungs schutz 4 nF 1 pF Messung im REL Modus 4 10 St 40 nF 10 pF 400 nF 100 pF 600 Vss 4 uF 1nF 4 3 St 40 uF 10 nF 400 uF 100 nF 4 mF 1 uF 5