1. The top may be washed in a dishwasher and or autoclaved Gutta Percha residue may be removed from the heat chamber and ceramic elements by the use of a blunt plastic instrument The main part of the heater may be wiped with a slightly damp cloth using standard cleaning solutions and surface disinfection products Packaging Contents ofthe HEROfill Kit e 1 HEROfill Oven e 1 pack of 6 Obturators n 25 e 2 packs of 6 Obturators n 30 e 1 pack of 6 Verifiers n 25 x 2 and n 30 x 4 HEROfill Kit References EU Connection REF 20638001 N UK Connection REF 20638002 N HEROfill Obturators References HEROfill Obturator n 20 Ref 20138501 N HEROfill Obturator n 25 Ref 20138502 N HEROfill Obturator n 30 Ref 20138503 N HEROfill Obturator n 35 Ref 20138504 N HEROfill Obturator n 40 Ref 20138505 N HEROfill Obturator n 45 Ref 20138506 N Accessories References HEROfill Verifier n 20 Ref 20139501 N HEROfill Verifier n 25 Ref 20139502 N HEROfill Verifier n 30 Ref 20139503 N HEROfill Verifier n 35 Ref 20139504 N HEROfill Verifier n 40 Ref 20139505 N HEROfill Verifier n 45 Ref 20139506 N 23 Your Endo Specialist Service and repair Inspections and repairs may only be carried out by an approved dealer or by MICRO MEGA Your MICRO MEGA product is an accurate medical device produced under maximum quality and test conditions To guarantee personal follow up and traceabil
2. Mode d emploi Operation instructions Bedienungsanleitung Your Endo Specialist Notice d utilisation pour les obturateurs HEROfill et les HEROfill Verifiers Classification L obturateur HEROfill est un dispositif m dical classe IIA conform ment la directive sur les dispositifs m dicaux 93 42 CE L usage des obturateurs HEROfill est r serv aux praticiens de l art dentaire Avertissements g n raux e Usage r serv aux praticiens de l art dentaire e Utiliser le produit uniquement pour les traitements canalaires des dents e Ne jamais utiliser un produit d form ou d fectueux e Le fabricant d cline toute responsabilit pour les pr judices corporels et dommages mat riels caus s par une mauvaise utilisation et ou un emploi inappropri Consulter la description de la m thode tape par tape section 2 pour plus d informations sur l utilisation du produit e Le produit doit tre conserv dans son emballage d origine Avertissements obturateurs HEROfill e Apres le cycle de chauffage la gutta percha est tr s chaude Eviter tout contact direct de obturateur HEROfill avec la peau ou les muqueuses L obturateur HEROfill doit tre ins r directement dans le canal e est toujours recommand d effectuer une radiographie de contr le Si la radiographie n est pas satisfaisante effectuer une nouvelle radiographie d un angle different Si obturation n est toujours pas doc
3. aide d un instrument mouss Le corps du rechauffeur peut tre nettoy l aide d un chiffon l g rement humide d une solution d tergente standard et de produits de d sinfection de surfaces Emballage Contenu du Kit HEROfill e 1r chauffeur HEROfill e 1 paquet de 6 obturateurs n 25 e 2 paquets de 6 obturateurs n 30 e 1 paquet de 6 Verifiers n 25 x 2 et n 30 x 4 Kit HEROfill References Connexion EU REF 20638001 N Connexion UK REF 20638002 N Obturateurs HEROfill References Obturateur HEROfill n 20 R f 20138501 N Obturateur HEROfill n 25 R f 20138502 N Obturateur HEROfill n 30 R f 20138503 N Obturateur HEROfill n 35 R f 20138504 N Obturateur HEROfill n 40 Ref 20138505 N Obturateur HEROfill n 45 R f 20138506 N Accessoires References HEROfill Verifier n 20 Ref 20139501 N HEROfill Verifier n 25 Ref 20139502 N HEROfill Verifier n 30 R f 20139503 N HEROfill Verifier n 35 Ref 20139504 N HEROfill Verifier n 40 R f 20139505 N HEROfill Verifier n 45 R f 20139506 N 11 Your Endo Specialist Garantie et suivi Pour toute revision ou r paration renvoyer le rechauffeur soit chez le distributeur agr soit directement chez MICRO MEGA Votre produit MICRO MEGA est un dispositif medical de pr cision fabriqu dans des conditions maxima de qualit et contr le Pour en assurer le suivi individualis et la tra ab
4. berstehenden Teil abbrechen 2 Den Kunststoffstift mit einem Finger festhalten und den Griff und den berstehenden Kunststoffstift mit einem kleinen umgekehrten Kegelbohrer abschneiden Eine vertikale Bewegung des Kunststoffstifts vermeiden um die apikale Versiegelung nicht zu beeintr chtigen bersch ssige Guttapercha mit einem Endo Exkavator oder einem hnlichen Instrument entfernen 3 Tipps zur Technik Die Verwendung des HEROfill Systems ist sehr einfach Das Feedback erfahrener HEROfill Nutzer wird Ihnen den ersten Gebrauch hoffentlich noch leichter machen F llung mehrwurzeliger Z hne Jeder HEROfill Obturator verf gt fast in jedem Fall ber eine ausreichende Menge Guttapercha Bei der Wurzelkanalf llung k nnen bersch ssige Guttapercha und F llpaste in den Koronalbereich des Zahns quellen und die angrenzende Wurzelkanal ffnung bedecken Dies kann folgenderma en vermieden werden e Den k rzesten Kanal zuerst f llen e Vor der Obturation Papierspitzen oder HEROfill Verifier in die anderen Kan le geben damit die Kanaleing nge nicht von Guttapercha bedeckt werden Die Papierspitzen und HEROfill Verifiers unmittelbar vor der F llung des betroffenen Kanals entfernen e Jeder HEROfill Obturator verf gt ber eine ausreichende Menge Guttapercha um lange breite oder stark resorbierende Wurzelkan le zu f llen Die Guttapercha Menge kann jedoch in einigen F llen zu gro sein Wenn schon im Voraus offe
5. Utiliser l instrument vitesse basse 250 400 tr mn et tourner doucement autour de l me plastique jusqu ce qu une r sistance se fasse sentir L instrument s implante entre la paroi canalaire et l me plastique L me plastique sera ainsi extraite du canal 2 Si n cessaire une petite lime manuelle type H peut tre ins r e dans le canal le long de l me plastique en direction apicale 3 Une fois l me plastique extraite du canal la gutta percha peut tre retir e l aide de m thodes conventionnelles 6 Symboles MN u E Lire la notice d utilisation 8 NE Date de p remption LOT CE Classe HEROfill Verifiers CE 0459 Classe lla Obturateurs HEROfilI 0459 Pour toute information compl mentaire contacter votre distributeur local Your Endo Specialist R chauffeur HEROfill Instructions d utilisation Classification Le r chauffeur HEROfill est un dispositif m dical classe I conform ment a la directive sur les dispositifs m dicaux 93 42 CE Le r chauffeur HEROfill doit tre utilis uniquement pour actes dentaires d obturation r alis s par des chirurgiens dentistes et pour le r chauffage exclusif des obturateurs HEROfill Le r chauffeur HEROfill comporte une chambre de r chauffage compos e de 5 cartes de circuit imprim avec des fils de cuivre La chaleur est produite par l alimentation des fils de cuivre Le r chauffeur est aliment par une arri
6. a thin layer of sealer on the canal walls When obturating multiple canals apply sealer in all canals at once STEP 4 Insertion of the HEROfill Obturator into the canal When the heater indicates that the HEROfill Obturator is ready for use the HEROfill Obturator is removed from the HEROfill Oven For further information on how the HEROfill Oven works please consult the appropriate heater manual Without twisting the handle immediately insert the HEROfill Obturator into the canal to the working distance using a firm and steady pressure A4 STEP 5 Confirming radiograph Confirm your root canal treatment by taking radiographs 16 Your Endo Specialist STEP 6 Removal of excess central carrier and Gutta Percha When the Gutta Percha has hardened after 2 3 min remove the handle in one of two ways A5 1 Lean the handle and metal insertion pin sharply to one side to break off the excess 2 Stabilize the plastic carrier with a finger and cut away the handle and excess plastic core with a small inverted cone bur Be careful to prevent vertical movement of the carrier to minimize the chance of disturbing the apical seal Trim away the extra Gutta Percha using an endo excavator or similar instrument 3 Technique tips It is very easy to use the HEROfill system Feed back from experienced HEROfill system users however will hopefully make it even easier for you to get started Obturating multi rooted cases T
7. be determined by use of x ray file and electronic apex locator Generally the appropriate size HEROfill Obturator will be the same size as the last file used at the apex of the canal Tip For very narrow and or highly calcified canals it may be useful to select one size smaller than the last file used at apex If you do not use rotary files with a taper of 4 or more you should always verify the size of the cleaned root canal with a HEROfill Verifier before inserting the HEROfill Obturator Mark your working length on your HEROfill Obturator When the HEROfill Verifier has a slightly loose fit in the apical third the rubber stop is placed at the working length Afterwards the working length is transferred to the HEROfill Obturator 15 Your Endo Specialist STEP 2 Heating of the HEROfill Obturator Place the selected HEROfill Obturator in the HEROfill Oven and activate it A2 A3 For more information on how to use the HEROfill Oven please consult page 19 STEP 3 Application of sealer While the HEROFill Obturator is heating mix any heat resistant sealer usually a non eugenol sealer MM Seal recommended with long working time Make sure that the root canal is completely dry before applying the sealer Place a very thin coating of sealer on the wall of the canal Too much the sealer is neither desirable nor necessary Utilize a Paper Point MM Paper Points recommended or a HEROfill Verifier to apply
8. local supplier for more information 19 Your Endo Specialist HEROfill Oven Operation Instructions Classification The HEROfill Oven is a medical device class in compliance with MDD Medical Devices Directive 93 42 CE The heater must only be used in dental clinics by dental personnel and only for heating of HEROfill Obturator The HEROfill Oven has a heat chamber that consists of 5 printed circuit boards with cobber lanes By applying power to the cobber lanes heat is generated The oven is driven by an external power supply Warning Do not touch the inside of the heat chamber before the oven is completely cooled off Technical specifications POWER SUPPLY Input power 100 240V AC 50 60Hz Output power 9V DC 1 7A SAFETY Auto turn off The heater turns off automatically after 9 hours Heating times HEROfill Obturator heating time is 60 seconds Preheating of the heater takes 3 4 minutes depending of surrounding temperature 20 MICRO MEG Your Endo Specialist 1 Start using the heater 1 Connect the power supply to the DC inlet of the heater and the mains and switch on power B1 2 Indicator A emits a red light while the HEROfill Oven preheats B2 When the HEROfill Oven is ready the indicator emits a green light and you will hear a beep Notice The HEROfill Oven can be left on the entire day 2 Use When the heater is ready for use up to four HEROfill
9. EROfill Verifier Nr 40 Ref 20139505 N HEROfill Verifier Nr 45 Ref 20139506 N Garantie und Service nach dem Kauf Inspektionen und Reparaturen sollten ausschlie lich bei einem autorisierten H ndler oder vom Hersteller MICRO MEGA durchgef hrt werden Ihr MICRO MEGA Produkt ist ein medizinisches Pr zisionsger t das unter h chsten Qualit ts und Testbedingungen hergestellt wurde Um die pers nliche Nacherfassung und die R ckf hrbarkeit seiner medizinischen Ger te zu gew hrleisten empfiehlt MICRO MEGA Ihnen die Garantiekarte innerhalb von 10 Tagen nach Erwerb ausgef llt zur ckzusenden Mit dieser R cksendung sichern Sie sich Kundendienstleistungen f r Ihr Produkt und erm glichen es MICRO MEGA Ihre Serviceanspr che zu Ihrer vollen Zufriedenheit zu erf llen und Ihre Garantie korrekt zu verwalten Sie k nnen die Garantie f r Ihr Produkt auch auf unserer Webseite anmelden unter www micro mega com MICRO MEGA gew hrt zwei Jahre Garantie auf Ihren HEROfill Ofen auf versteckte Herstellungsfehler Ausgeschlossen sind Fehler die zur ckzuf hren sind auf Unsachgem en Gebrauch Unsachgem e Wartung oder Anwendung die die Gebrauchsempfehlungen und anleitungen missachtet Unfallsch den durch Fallenlassen St e usw Eingriffs bzw Reparaturversuche durch Personen die nicht von MICRO MEGA befugt sind Versuchte Ab nderungen des Produkts Entsorgung von Elektro und Elektronik Altger ten innerhalb der E
10. Obturators at a time may be placed in the appropriate slots Place the HEROfill Obturators in slots marked 1 to 4 B3 Tip Place the HEROfill Obturator to be used first in slot 1 the second in 2 etc generally you should begin with the smallest size HEROfill Obturator 21 MICRO MEGA Your Endo Specialist 1 Activate the timer by pressing the ON icon B4 2 Indicator B lights red during the heating cycle 3 When ready the indicator changes to green and you will hear a beep B4 Let the HEROfill Obturator stay in the heater until you are ready to insert it max 15 min 4 It is possible to turn off the HEROfill Oven by holding down the ON button for 2 seconds B4 The HEROfill Oven beeps three times it indicate it is switched off Hold down the ON button for 2 seconds to reactivate the heater Tip You do not have to turn off the HEROfill Oven after finished treatment the HEROfill Oven can be left on standby all day Indication light and sound Le d Sg e T eo Tom ger som obrar E me ume 6e sonner SSC IESSE atotumot _ eg 22 MICRO MEG Your Endo Specialist 3 Cleaning Disconnect the HEROfill Oven from the main When the HEROfill Oven has cooled completely Gutta Percha residue may easily be removed The top of the HEROfill Oven may be removed for cleaning by rotating the top counter clockwise 1 until the top is loose and can be removed 2 B5
11. ROfill Ofen Bedienungsanleitung Klassifizierung Der HEROfill Ofen ist ein medizinisches Ger t der Klasse gem der Medizinproduktrichtlinie MDD Medical Device Directive 93 42 EG Der Erhitzer darf nur von Fachkr ften in Zahnkliniken zur Erhitzung von HEROfill Obturatoren verwendet werden Der HEROfill Ofen verf gt ber eine Heizkammer die aus 5 gedruckten Leiterplatten mit Kupferdr hten besteht Durch Spannungsversorgung der Kupferdr hte wird W rme erzeugt Der Ofen wird von einer externen Stromversorgung betrieben Warnhinweis Nicht das Innere der Heizkammer ber hren bevor der Ofen nicht vollst ndig abgek hlt ist Technische Daten STROMVERSORGUNG Eingangsleistung 100 240V AC 50 60Hz Ausgangsleistung 9V DC 1 7A SICHERHEIT Automatische Abschaltfunktion Der Erhitzer schaltet sich nach 9 Stunden automatisch ab Erhitzungszeiten Die Erhitzungszeit f r HEROfill Obturatoren betr gt 60 Sekunden Je nach Umgebungstemperatur dauert die Vorerhitzung 3 4 Minuten 32 MICRO MEG Your Endo Specialist 1 Vor Benutzung des Erhitzers 1 Schlie en Sie das Netzteil an den DC Eingang des Erhitzers und an das Stromnetz an und schalten Sie das Ger t ein B1 2 Die Anzeige A leuchtet w hrend der Vorerhitzungszeit des HEROfill Ofens rot auf B2 Wenn der HEROfill Ofen betriebsbereit ist leuchtet die Anzeige gr n auf und der Ofen gibt ein akustisches Signal ab Anmerkung De
12. The sizes are 20 to 45 according to ISO standard The HEROfill Obturator sizes correspond to the ISO standards of root canal files A single HEROfill Obturator is all that is needed to obturate a root canal fully The result should always be a perfectly placed root canal filling with a tight apical Seal The HEROfill Verifier is an uncoated core that has exactly the same dimensions as the obturator core and is used to confirm that the size selected provides the proper fit The shaft of the HEROfill Verifier has working distance circular bands at 18 19 20 21 and 22 mm A HEROfill Obturator consists of three parts 1 Plastic handle with a metal insertion pin The plastic handle is color coded according to the size of the HEROfill Obturator The stainless steel insertion pin is 9 mm long and is permanently attached to the plastic handle The metal insertion pin is placed 6 mm down in the plastic carrier When the metal insertion pin is removed it will leave a hollow part of 6 mm in the plastic carrier 14 Your Endo Specialist 2 Outer layer of thermoplastic Natural Gutta Percha The Gutta Percha is reversible thermoplastic This means that it becomes soft and highly adhesive when heated to temperatures above approx 100 C When cooled it returns to a firm rigid state Another heating will once again make the Gutta Percha soft and adhesive 3 Plastic carrier with endo stop The tapered plastic carrier is sufficiently flexi
13. U Gem der WEEE Richtlinie Waste of Electrical and Electronic Equipment deutsch Elektro und Elektronikger te Abfall 2002 96 EG vom 27 Januar 2003 36 Your Endo Specialist Entsorgung von Elektro und Elektronik Altger ten innerhalb der EU 11 Elektro und Elektronik Altger te d rfen nicht mit dem normalen Haushaltsm ll entsorgt werden 12 Elektro und Elektronik Altger te m ssen separat gesammelt werden 13 Das Ger t muss einem anerkannten Entsorgungsbetrieb bergeben werden 14 Das Ger t kann nach Ablauf seiner Lebensdauer nicht wiederverwendet werden 15 Elektro und Elektronik Altger te verschmutzen die Umwelt und sch digen so die Gesundheit von Lebewesen Leitfaden f r die Sterilisation des abnehmbaren Oberteils WARNHINWEISE BESCH DIGTE PRODUKTE ENTSORGEN Einschr nkungen der Wiederaufbereitung 250 Zyklen berm igen Schmutz mit einem Verwendungsort Einmaltuch Papiertuch entfernen Vorbereitung f r die Dekontamination Keine spezifischen Anforderungen Reinigung automatisiert Nicht empfohlen Ausr stung Reinigungsmittel B rste destilliertes oder demineralisiertes Wasser 1 berm igen Schmutz von der Abdeckung Reinigung manuell absp len 2 Mit der B rste Reinigungsl sung auf alle Oberfl chen auftragen 3 Unter klarem laufendem Wasser absp len Vakuum Autoklav mindestens 18 Minuten bei 134 Sterilisation C Druck 2 2 bar Eine Temperatur von 134 C nicht bers
14. ble to negotiate curved canals The HEROfill Obturator plastic carrier is slightly tapered This insures adequate back flow of the heated Gutta Percha The length of the carrier is 24 mm The coronal 6 mm of the carrier is hollow to accommodate the metal insertion pin A rubber endo stop is provided to indicate the working distance measurement The plastic carrier and Gutta Percha are radiopaque 2 A step by step guide After having ideally used the One Shape or Revo S methods for the shaping and before using the HEROfill Obturator assure that you have achieved the following e A properly cleaned and shaped canal the key to any successful root canal filling e A dry root canal e An established working length The plastic carrier is flexible enough to negotiate curved canals It is highly advised that rotary files with a higher conicity are utilized to create a sufficient taper for the HEROfill Obturator When using files with a conicity of 2 it is advised to combine them with a procedure using Gates Glidden Drills orifice openers ENDOFLARE for example or similar files which can be used to create a sufficient opening in the coronal part of the canal The use of HEROfill Verifiers is recommended STEP 1 Determine the working length and choose the proper HEROfill Obturator size The working length is measured all the way to the apex 41 We recommend measuring the working length from the edge of the cusp The working length may
15. bturation du canal l exc dent de gutta percha remblayera jusqu la partie coronaire de la dent et risquera de recouvrir et bloquer l entr e du canal adjacent Pour viter ce ph nom ne e Obturer le canal le plus court en premier e Placer des pointes de papier ou des HEROfill Verifiers dans les autres canaux avant l obturation afin de les emp cher d tre recouverts de gutta percha Les retirer un un pour r aliser les obturations e Chaque obturateur poss de la quantit n cessaire de gutta percha pour obturer m me les canaux longs larges ou avec r sorption interne Toutefois cela peut tre trop dans certains cas Si un exc s de gutta percha dans le canal para t vident utiliser une lame tranchante pour enlever de la gutta percha de l extr mit coronaire de l me plastique avant de chauffer l instrument e Dans certains cas notamment pour les dents multi radicul es il peut tre utile de retirer le manche et la tige m tallique de l me plastique afin de cr er un espace qui facilitera l insertion du prochain obturateur dans le second et le troisi me canal Your Endo Specialist Avant de r chauffer le ou les obturateurs et m me avant de marquer la longueur de travail s assurer toujours que le manche la tige m tallique peut tre s par e de l me plastique Pour cela il faut tourner le manche la tige m tallique en le la retirant de l me plastique R ins rer ensuite le manche la tige m
16. cha et l me par friction Il est possible d utiliser des fraises coupantes Dans ce cas veiller viter toute perforation Si vous utilisez un polissoir ou une fraise ronde 1 Utiliser un contre angle haute vitesse avec un syst me de refroidissement d eau 2 Commencer par le num ro de fraise ronde le plus lev adapt la taille de l entr e canalaire sans toucher les parois 3 Placer la fraise au centre du creux de l me plastique en exer ant une l g re pression Appuyer sur la p dale du moteur par intermittence pour permettre la fraise de retirer ou de ramollir me plastique 4 Lorsque le canal se r tr cit passer un diam tre de fraise inf rieur afin de ne pas abimer les parois Continuer cette op ration jusqu ce que la profondeur d sir e soit atteinte 5 Retraitement d un canal obtur Il est relativement simple de retirer l obturateur HEROfill avant que la gutta percha ne refroidisse suffit de saisir la partie plastique qui d passe l aide de pr celles et de la retirer Une fois la gutta percha refroidie ou pour une reprise de traitement lors du rendez vous suivant le retrait est effectuer en utilisant de pr f rence un foret Peeso Gates ou un instrument similaire MM MEGA Your Endo Specialist 1 Placer le foret entre la paroi canalaire et l me plastique de mani re que le sens de rotation sera dans le sens inverse des aiguilles d une montre
17. chreiten Keine besonderen Anforderungen 37 Your Endo Specialist 4 Symbole Hersteller Bedienungsanleitung lesen Seriennummer Richtlinie f r medizinische elektrische Ger te EN 60601 1 2006 Schutz vor elektrischem Schlag Typ B Medizinproduktrichtlinie MDD Richtlinie 93 42 EWG Medizinisches Ger t Klasse WEEE Richtlinie Waste of Electrical and Electronic Equipment deutsch Elektro und Elektronikger te Abfall 2002 96 EG Bitte geben Sie das Produkt zwecks Recycling bei einer anerkannten Entsorgungsstelle ab 38 Your Endo Specialist 39 Annee apposition marquage CE 2000 Year of CE marking 2000 CE Kennzeichnung 2000 www micro mega com Ml MICRO MEGA Instruments de chirurgie dentaire Dental instruments Zahn rztlichen Instrumenten 5 12 rue du Tunnel 25006 Besan on Cedex France Tel 33 0 3 81 54 42 43 Fax 33 0 3 81 54 42 30 mmb micro mega com Ref 60300573 C 07 14
18. e in der Regel eugenolfrei wir empfehlen MM Seal mit langer Verarbeitungszeit nutzen Sich vor dem Einbringen der F llpaste vergewissern dass der Wurzelkanal komplett trocken ist Eine d nne Schicht der F llpaste auf die Kanalw nde auftragen Zu viel F llpaste ist weder notwendig noch w nschenswert Eine Papierspitze wir empfehlen MM Paper Points oder einen HEROfill Verifier benutzen um eine d nne Schicht der F llpaste auf die Kanalw nde aufzutragen Bei der Obturation mehrerer Kan le die F llpaste gleich in alle Kan le einbringen SCHRITT 4 Einf hren des HEROfill Obturators in den Wurzelkanal Wenn der Ofen anzeigt dass der HEROfill Obturator gebrauchsfertig ist den HEROfill Obturator aus dem HEROfill Ofen nehmen F r n here Informationen zum Gebrauch des HEROfill Ofens die entsprechende Bedienungsanleitung lesen Den HEROfill Obturator sofort unter kr ftiger und gleichm iger Druckaus bung bis zur Arbeitsl nge in den Wurzelkanal einf hren ohne dabei den Griff zu drehen A4 28 Your Endo Specialist SCHRITT 5 Kontrollr ntgenaufnahme Durch Anfertigung von R ntgenaufnahmen das Ergebnis der Wurzelkanalbehandlung berpr fen SCHRITT 6 Entfernen des berstehenden Metallstifts und der bersch ssigen Guttapercha Wenn die Guttapercha hart ist nach 2 3 Min den Griff unter Anwendung einer von zwei Methoden entfernen A5 1 Den Griff und den Metallstift scharf umbiegen und den
19. ente un ajustement l g rement libre dans le tiers apical placer la rondelle stop en caoutchouc la longueur D D D YA 7 D de travail La longueur de travail est ensuite transf r e sur l obturateur HEROfill MICRO MEG Your Endo Specialist ETAPE 2 Chauffage de l obturateur HEROfill Placer l obturateur HEROfill s lectionn dans le r chauffeur HEROfill et d marrer l appareil A2 A3 Lire page 7 pour plus d informations sur l utilisation du r chauffeur HEROfill ETAPE 3 Application d un ciment de scellement 2 s Pendant que l obturateur HEROfill est en train de chauffer m langer un ciment de scellement r sistant a la chaleur g n ralement sans eug nol par exemple MM Seal avec un temps de prise lev S assurer que le canal est completement sec avant d appliquer le ciment de scellement Enduire les parois du canal d une fine couche de ciment de scellement Une couche trop paisse n est ni n cessaire ni souhaitable Utiliser une pointe de papier MM Paper Points recommand s ou un HEROfill Verifier afin d appliquer une fine couche de ciment de scellement sur les parois du canal Pour l obturation de canaux multiples appliquer le ciment de scellement imm diatement dans tous les canaux ETAPE 4 Insertion de l obturateur HEROfill dans le canal Quand le r chauffeur indique que l obturateur HEROfill est pr t pour l emploi retirer l obturateur HEROfill du r chauf
20. ert the handle metal insertion pin into the plastic carrier Mark your working length and proceed to STEP 2 STEP 4 section 2 Stabilize the plastic carrier with a cotton plier while the handle metal insertion pin is twisted out Any excess material is removed as described in STEP 5 section 2 Use of sealer As with any other root filling technique when using the HEROfill System always apply sealer in the canal first However there is a significant difference when using HEROfill System Only apply a very small amount using a HEROfill Verifier or a Paper Point A root spiral should not be utilized when using HEROfill Obturators as there is a tendency to add too much sealer to the canal Remember only apply a very thin layer of sealer on the canal walls 4 Post space preparation Post space creation can be accomplished by removing the coronal portion of the obturation Since 6 mm of the plastic core is hollow this procedure should be easier compared to solid core obturators Smooth round burs preferably a ball burnisher with no cutting flutes are the most effective since they do not cut but instead melt the gutta percha and central core by friction Cutting burs may be used but care should be taken to prevent perforation Using a round bur or ball burnisher 1 Use a high speed hand piece with water coolant 2 Begin with the largest size round bur that will fit in the access opening of the canal without touching t
21. feur HEROfill Lire la notice d utilisation correspondante pour plus d informations sur le fonctionnement et l utilisation du r chauffeur HEROfill Ins rer l obturateur HEROfill imm diatement dans le canal jusqu la longueur de travail en exer ant une pression ferme et constante sur l obturateur et sans tordre le manche 44 ETAPE 5 Radiographie de validation Valider le traitement canalaire l aide de radiographies Your Endo Specialist ETAPE 6 Elimination de l me centrale et de la gutta percha exc dentaires Quand la gutta percha a pris au bout de 2 3 minutes retirer le manche en choisissant parmi deux m thodes A5 1 Plier le manche et la tige m tallique d un c t afin de d tacher l exc dent 2 Stabiliser l me plastique avec un doigt et couper le manche et l me plastique exc dentaire avec une petite fraise conique renvers e Veiller viter un mouvement vertical de l me afin de ne pas alt rer le scellement apical Couper l exc dent de gutta percha l aide d un endo excavateur ou d un instrument similaire 3 Astuces techniques L utilisation du syst me HEROfill est tr s facile N anmoins nous esp rons que le retour d utilisateurs exp riment s du syst me HEROfill vous facilitera encore plus la premi re utilisation Dents multi radicul es Dans presque tous les cas la quantit de gutta percha sur chaque obturateur HEROfill sera suffisante Lors de l o
22. fisant du tiers coronaire pour permettre le passage de l obturateur En cas d utilisation de limes avec une conicit de 2 il est conseill de les combiner avec une m thode employant des forets de Gates des limes de pr paration de la cavit d acces ex ENDOFLARE ou des limes similaires qui peuvent tre utilis es pour am liorer les acc s aux entr es canalaires dans la partie coronaire L emploi des HEROfill Verifiers est recommand ETAPE 1 D termination de la longueur de travail et choix de l obturateur HEROfill La longueur de travail est mesur e jusqu l apex A1 Il est recommand de mesurer la longueur de travail a partir du bord de l entr e du canal La longueur de travail peut tre d termin e l aide de radiographies d une lime ou d un localisateur d apex En g n ral il sera du m me num ro que le dernier instrument utilis l apex lors de la pr paration Astuce Pour les canaux troits et ou calcifi s s lectionner l obturateur de diam tre juste inf rieur au dernier instrument utilis Si vous n utilisez pas d instruments rotatifs avec une conicit de 4 ou plus vous devez toujours YA s D v rifier les dimensions du canal l aide d un HEROfill Verifier apr s la pr paration canalaire et avant Y 8 d ins rer l obturateur HEROfill D s D YA Marquer la longueur de travail mesur e sur l obturateur HEROfill Quand l obturateur pr s
23. he walls 3 Place the bur in the centre of the hollow core using a gentle relaxed pressure Intermittently pulse the foot controller to allow the bur to remove or melt the plastic core 4 Change to smaller diameter burs as the canal tapers to prevent damage to the walls until the desired depth is reached 5 Retreatment of an obturated root canal Removal of the HEROfill Obturator is relatively simple prior to the Gutta Percha cooling Simply grasp the excess carrier with cotton pliers and remove it Once the Gutta Percha has cooled or for retreatment at a later appointment removal is easiest achieved by using a Peeso bur Gates or similar 1 Place the bur between the canal wall and the plastic carrier so that the rotational direction will be counter clockwise Use the instrument at very low speeds 250 400 rpm and work slowly around the plastic carrier until you feel resistance The instrument will grasp between the plastic carrier and the canal wall The plastic carrier will be coiled out of the canal after a short time 18 Your Endo Specialist 2 If necessary a small Hedstrom hand file can be worked down apically along the plastic carrier 3 When the plastic carrier has been pulled out of the canal the Gutta Percha is removed by traditional means 6 Labelling Manufacturer See instruction manual HEN u CE Class I HEROfill Verifiers CE 0459 Class lla HEROfill Obturators 0459 Contact your
24. here will almost always be more than enough Gutta Percha on each HEROfill Obturator When obturating the canal the excess Gutta Percha and sealer will backfill to the coronal part of the tooth possibly blocking the adjacent opening However you can avoid this e Obturate the shortest canal first e Place Paper Points or HEROfill Verifier in the other canals prior to obturation to prevent the following root canals in being blocked by Gutta Percha Remove Paper Points or size HEROfill Verifiers as each canal is obturated e While there is sufficient Gutta Percha on each HEROfill Obturator to fill even extremely long canals wide canals or internally resorbed canals it may be too much in some cases If it is obvious that there will be an excess of Gutta Percha to fill the canal use a sharp blade to trim some of the material from the coronal end of the central carrier prior to heating e In some cases it can be beneficial to remove the handle metal insertion pin from the actual plastic carrier especially in multi rooted teeth where the extra space will make it easier placing the following HEROfill Obturators in the second and third canal 17 Your Endo Specialist Prior to heating of the HEROfill Obturator s and prior to marking the working length always assure that the handle metal insertion pin can be separated from the plastic carrier This is done by twisting the handle metal insertion pin out of the plastic carrier Re ins
25. ilit due aux dispositifs m dicaux MICRO MEGA vous demande de lui retourner la carte de garantie d ment compl t e dans les 10 jours suivant votre achat Ce retour conditionne la mise en place de la proc dure de suivi de votre appareil qui permettra MICRO MEGA de vous donner toute satisfaction dans le service que vous attendez et la prise en charge de la garantie Vous pouvez aussi proc der l enregistrement de la garantie de votre appareil sur notre site internet www micro mega com MICRO MEGA garantit pour une dur e de 2 ans votre r chauffeur HEROfill contre tout vice cach de production a l exclusion des d fauts dus aune mauvaise utilisation un entretien ou un emploi inappropri s non conformes a nos recommandations et au mode d emploi une d t rioration accidentelle chute chocs etc une tentative d intervention ou de r paration par du personnel non agr par MICRO MEGA une tentative de modification Gestion des d chets au sein de l Union Europ enne Selon la directive DEEE 2002 96 CE du 27 Janvier 2003 Gestion des d chets au sein de la CEE 1 Les DEEE D chets d quipements lectriques et lectroniques ne doivent pas tre jet s avec les d chets provenant des m nages 2 Les DEEE doivent tre collect s s par ment 3 L quipement doit tre retrait dans un centre de retraitement agr 4 L quipement ne peut pas tre r utilis en fin de vie 5 Les DEEE
26. ine Warnhinweise e Das Produkt ist ausschlie lich f r den professionellen zahnmedizinischen Gebrauch bestimmt e Das Produkt sollte nur zur Behandlung von Wurzelkan len in Z hnen verwendet werden e Ein verformtes oder besch digtes Produkt sollte niemals verwendet sondern umgehend entsorgt werden e Der Hersteller lehnt jede Verantwortung und Haftung f r Verletzungen oder Personen und Sachsch den ab die auf eine falsche und oder unsachgem e Benutzung zur ckzuf hren sind F r Informationen zum korrekten Gebrauch des Produkts die Schritt f r Schritt Anleitung lesen Abschnitt 2 e Das Produkt sollte originalverpackt gelagert werden Warnhinweise HEROfill Obturator e Nach dem Erhitzen ist die Guttapercha hei Jeden direkten Kontakt des HEROfill Obturators mit der Haut und den Schleimh uten vermeiden Der HEROfill Obturator sollte direkt in den Wurzelkanal eingef hrt werden e Es wird stets empfohlen ein Kontrollr ntgenbild anzufertigen Wenn die R ntgenaufnahme nicht zufriedenstellend ist eine weitere R ntgenaufnahme aus einem anderen Winkel erstellen Wenn die F llung noch immer nicht zufriedenstellend belegt werden kann den HEROfill Obturator aus dem Kanal entfernen 1 Beschreibung Ein HEROfill Obturator ist ein mit thermoplastischer Guttapercha berzogener Kunststoffstift Er ist in den Gr en 20 bis 45 gem ISO Standard erh ltlich Die Gr en des HEROfill Obturators entsprechen den ISO Standa
27. inigung Den HEROfill Ofen vom Stromnetz trennen Wenn der HEROfill Ofen vollst ndig abgek hlt ist k nnen Guttapercha Reste leicht entfernt werden Die Abdeckung des HEROfill Ofens kann zur Reinigung durch Drehen gegen den Uhrzeigersinn 1 abgenommen werden 2 B5 Die Abdeckung kann in einer Sp lmaschine und oder in einem Autoklaven gereinigt werden Guttapercha Reste mithilfe eines stumpfen Instruments aus Kunststoff aus der Heizkammer und von den Keramikelementen entfernen Die Geh useoberfl che des Ger ts mit einem leicht feuchten Tuch und einem Reinigungs bzw Oberfl chendesinfektionsmittel s ubern Lieferumfang Inhalt des HEROfill Kits e 1HEROfill Ofen 1 Packung mit 6 Obturatoren Nr 25 2 Packungen mit 6 Obturatoren Nr 30 1 Packung mit 6 Verifiers Nr 25 x 2 und Nr 30 x 4 35 Mp MEGA Your Endo Specialist HEROfill Kit Referenzen EU Stecker REF 20638001 N UK Stecker REF 20638002 N HEROfill Obturatoren Referenzen HEROfill Obturator Nr 20 Ref 20138501 N HEROfill Obturator Nr 25 Ref 20138502 N HEROfill Obturator Nr 30 Ref 20138503 N HEROfill Obturator Nr 35 Ref 20138504 N HEROfill Obturator Nr 40 Ref 20138505 N HEROfill Obturator Nr 45 Ref 20138506 N Zubeh r Referenzen HEROfill Verifier Nr 20 Ref 20139501 N HEROfill Verifier Nr 25 Ref 20139502 N HEROfill Verifier Nr 30 Ref 20139503 N HEROfill Verifier Nr 35 Ref 20139504 N H
28. inuterie en pressant sur le symbole ON B4 2 Une lumi re rouge B s allume pendant le cycle de chauffe 3 Une fois pr t l indicateur devient vert et s accompagne d un signal sonore B4 Laisser les obturateurs dans le r chauffeur jusqu ce que vous soyez pr t a les ins rer max 15 min 4 ll est possible d teindre le r chauffeur HEROfill en maintenant appuy le bouton ON pendant 2 secondes B4 Le r chauffeur HEROfill met trois signaux sonores pour indiquer qu il est teint Maintenir appuy le bouton ON pendant 2 secondes afin de red marrer l appareil Astuce Vous n tes pas oblig d teindre le rechauffeur apr s chaque traitement L appareil peut rester en veille toute la journ e Indication lumi re et son H wo e o mre regar w o ETT RTE NC 10 MICRO MEGA Your Endo Specialist 3 Nettoyage D brancher le r chauffeur HEROfill Lorsque le r chauffeur a compl tement refroidi des r sidus de gutta percha peuvent facilement tre enlev s Le haut du r chauffeur peut tre enlev pour le nettoyage en effectuant une rotation contre le sens des aiguilles d une montre 1 jusqu ce que le haut soit d fait et puisse tre retir 2 B5 Le haut du r chauffeur peut tre nettoy en lave vaisselle et ou autoclave Les r sidus de gutta percha peuvent tre enlev s du r chauffeur et des l ments c ramiques en grattant d licatement le plastique l
29. itifs medicaux electriques EN 60601 1 2006 13 Your Endo Specialist HEROfill Obturator and Verifier Operation Instructions Classification The HEROfill Obturator is a medical device class IIA in compliance with MDD Medical Devices Directive 93 42 CE The HEROfill Obturator must only be used by dentists Read and follow the instructions carefully General precautions e The product should only be used by dentists e The product should only be used for root canal procedures in teeth e A deformed or defective product should never be used but should be discarded e The manufacturer disclaims all responsibility and liability for injury or damage to persons or property caused by faulty and or inappropriate use For information on the correct use of the product please see the step by step guide section 2 e The product should be stored in the original packing Warnings HEROfill Obturator e After heating the Gutta Percha is hot Avoid any direct contact between the HEROfill Obturator and skin or mucous membranes The HEROfill Obturator should be inserted directly into the root canal e It is always recommended to take a control x ray If the x ray is not satisfactory take another x ray from a different angle If the filling still can not be satisfactorily documented remove the HEROfill Obturator 1 Description A HEROfill Obturator is a carrier of plastic which is coated with thermoplastic Gutta Percha
30. ity of its medical devices MICRO MEGA would like you to return the guarantee card duly filled in within 10 days of your purchase This return ensures that the procedure for after sales care of your instrument will be instigated so that MICRO MEGA can give you full satisfaction with the service your expect and manage your guarantee correctly Your can also register the guarantee for your instrument on our website www micro mega com MICRO MEGA guarantees your HEROfill Oven for two years against any hidden manufacturing defect excluding faults due to Improper use Inappropriate maintenance or application not in accordance with our recommendations and instructions for use Accidental damage fall impact Attempted intervention or repair by personnel not approved by MICRO M EGA Attempted product modification Waste handling within the EC In compliance with the WEEE directive 2002 96 EC 27 January 2003 Waste disposal within the EEC 6 WEEE Waste of electrical and electronic equipment cannot be disposed with normal household waste 7 WEEE must be collected separately 8 The equipment has to be treated to an approved re treatment centre 9 The equipment cannot be reused after its lifetime has ended 10 WEEE pollutes the environment and thereby damages the health of living beings 24 Your Endo Specialist Sterilization guide for removable top part WARNINGS DISCHARGE DAMAGED PRODUCTS Limitations on re
31. lle La gutta percha est thermoplastique r versible Cela signifie qu elle devient molle et hautement adh sive lorsqu elle est chauff e des temp ratures sup rieures environ 100 C Inversement elle se rigidifie en refroidissant Un nouveau cycle de chauffe rendra la gutta percha de nouveau molle et hautement adh sive 3 Une me plastique avec une rondelle stop L ame plastique conique permet de traiter les canaux courbes gr ce a sa flexibilit L me plastique de l obturateur HEROfill pr sente une l g re conicit afin d assurer le reflux ad quate de la gutta percha chaude La longueur de l me plastique est de 24 mm La partie coronaire de l me est creuse et re oit la tige m tallique Une rondelle stop en caoutchouc permet le respect de la longueur de travail L me plastique et la gutta percha sont radio opaques 2 La m thode HEROfill tape par tape Apr s avoir id alement utilis One Shape ou Revo S pour la preparation canalaire et avant de r aliser une obturation selon la m thode HEROfill s assurer que e Le canal soit bien nettoy et mis en forme condition indispensable pour une obturation r ussie e Le canal soit sec e La longueur de travail soit d finie A noter que l me plastique est suffisamment flexible pour passer dans les canaux courbes ll est fortement recommand d utiliser des instruments rotatifs avec une conicit sup rieure afin de cr er un largissement suf
32. ls Der HEROfill Obturator l sst sich vor der Abk hlung der Guttapercha relativ leicht entfernen Dazu einfach den berstehenden Stift mit einer Pinzette ergreifen und entfernen 30 Your Endo Specialist Sobald die Guttapercha abgek hlt ist oder zwecks einer endodontischen Revision zu einem sp teren Zeitpunkt kann die Guttapercha am einfachsten mithilfe eines Peeso Bohrers eines Gates Glidden Bohrers oder einem hnlichen Instrument entfernt werden 1 Den Bohrer zwischen der Wurzelkanalwand und dem Kunststoffstift platzieren sodass der Bohrer gegen den Uhrzeigersinn rotiert Das Instrument bei sehr niedrigen Geschwindigkeiten 250 400 U min benutzen und langsam um den Kunststoffstift herumarbeiten bis ein Widerstand zu sp ren ist Das Instrument greift zwischen den Kunststoffstift und die Kanalwand Der Kunststoffstift wird schon nach kurzer Zeit aus dem Kanal gewunden 2 Bei Bedarf kann eine kleine Hedstr m Feile entlang des Kunststoffstifts in Richtung Apex eingef hrt werden 3 Sobald der Kunststoffstift aus dem Kanal gezogen wurde kann die Guttapercha mit traditionellen Mitteln aus dem Wurzelkanal entfernt werden Hersteller Bedienungsanleitung lesen Einmalgebrauch 6 Symbole NE Verfallsdatum LOT CE Klasse HEROFill Verifiers CE 0459 Klasse lla HEROfill Obturatoren 0459 F r weitere Informationen kontaktieren Sie bitte Ihren H ndler vor Ort 31 Your Endo Specialist HE
33. ng mit den HEROfill Obturatoren verwendet werden da diese dazu neigen zu viel F llpaste in den Kanal einzubringen 4 Schaffung eines Einsetzplatzes f r einen Wurzelstift Der Einsetzplatz f r einen Wurzelstift kann durch Entfernen des koronalen Endes des Obturators geschaffen werden Da 6 mm des Kunststoffstifts hohl sind ist dies meist einfacher als bei Obturatoren mit festem Stift Am effektivsten wird hierbei mit einem glatten runden Bohrer gearbeitet vorzugsweise einem Kugelpolierer ohne Schleifriffeln da solche Werkzeuge die Guttapercha und den Kunststoffstift nicht abschleifen sondern durch Reibungshitze wegschmelzen Es k nnen zwar auch schleifende Bohrer verwendet werden dabei muss jedoch darauf geachtet werden dass keine feinen L cher im Material entstehen Verwendung eines runden Bohrers oder Kugelpolierers 1 Ein Handst ck mit hoher Drehzahl und Wasserk hlung benutzen 2 Mit dem gr ten runden Bohrer beginnen der noch in die ffnung des Kanals passt ohne dessen Wand zu ber hren 3 Den Bohrer mit leichtem Druck in der Mitte des hohlen Kunststoffstifts platzieren Den Fu schalter mehrfach in kurzen Abst nden bet tigen damit der Bohrer den Kunststoffstift entfernen oder schmelzen kann 4 Mit einem enger werdenden Kanal zu d nneren Bohrern wechseln um eine Besch digung der W nde zu vermeiden und sich bis zur gew nschten Tiefe vorarbeiten 5 Endodontische Revision eines gef llten Wurzelkana
34. nsichtlich ist dass die Guttapercha Menge f r den zu 29 Your Endo Specialist obturierenden Kanal zu gro ist am besten bereits vor dem Erhitzen am koronalen Ende des zentralen Kunststoffstifts mit einem scharfen Messer etwas Material abschneiden e In gewissen F llen und insbesondere bei mehrwurzeligen Z hnen kann es hilfreich sein den Griff Metallstift vom Kunststoffstift zu entfernen um mehr Platz f r die Einf hrung der folgenden HEROfill Obturatoren in den zweiten und dritten Kanal zu schaffen Sich vor dem Erhitzen des HEROfill Obturators und der Markierung der Arbeitsl nge immer vergewissern dass der Griff Metallstift durch Herausdrehen vom Kunststoffstift entfernt werden kann Nach diesem Test den Griff Metallstift wieder in den Kunststoffstift einf hren Die Arbeitsl nge markieren und mit den SCHRITTEN 2 4 fortfahren Abschnitt 2 Den Kunststoffstift mit einer Pinzette festhalten und den Griff Metallstift herausdrehen bersch ssiges Material wird wie in SCHRITT 5 Abschnitt 2 beschrieben entfernt Verwendung von F llpaste Wie bei jeder anderen Wurzelkanalf llmethode wird auch mit dem HEROfill System immer zuerst F llpaste in den Wurzelkanal eingebracht Jedoch besteht ein bedeutender Unterschied bei der Verwendung des HEROFill Systems Es darf nur eine kleine Menge F llpaste mit einem HEROFill Verifier oder einer Papierspitze in den Kanal gegeben werden Es sollte kein Kondensor in Verbindu
35. polluent l environnement et sont nocifs pour la sant des tres vivants 12 Your Endo Specialist Indications pour la st rilisation de la partie haute d montable AVERTISSEMENTS JETER TOUT PRODUIT ENDOMMAGE Limites de retraitement 250 cycles INSTRUCTIONS TR Retirer l exces de salissure avec une lingette Lieu d utilisation jetable un tissu en papier Pr paration en vue de la d contamination Aucune exigence sp cifique Nettoyage automatis Non recommand Equipement d tergent brosse eau distill e ou d min ralis e 1 Rincer afin de retirer l exc s de salissure de la Nettoyage manuel partie haute 2 Appliquer du d tergent sur toutes les surfaces l aide de la brosse 3 Rincer l eau claire courante Ne pas d passer 134 C Maintenance inspection et essais Jeter tout produit endommag Emballage Emballer s par ment seulement STEEN Autoclave a vide 18 minutes minimum 134 C Sterilisation i S pression 2 2 bar Ne pas depasser 134 C Stockage Aucune exigence particuliere 4 Symboles Lire la notice d utilisation Numero de serie Protection contre les chocs lectriques type B Directive sur les dispositifs m dicaux 93 42 CEE Dispositif m dical classe Directive sur les d chets d quipements lectriques et lectroniques Directive DEEE 2002 96 CE Veuillez retourner le produit dans un centre de recyclage appropri m Directive relative aux dispos
36. processing 250 cycles INSTRUCTIONS Remove ex il with di le cloth paper Preparation for decontamination No specific requirements Cleaning Automated Not recommended Equipment Detergent brush distilled or demineralised water 1 Rinse excess soil from cover 2 Using brush apply detergent solution to all surfaces 3 Rinse under clear running water Not recommended Do not exceed 134 C Maintenance inspection and testing Discharge damaged products Packaging Only pack individually Sterilization Vacuum autoclave minimum 18 minutes at 1342 C pressure 2 2 bar Do not exceed 134 C Storage No particular requirement Cleaning Manual 4 Labelling Manufacturer See instruction manual Serial number Medical Electrical Equipment Directive EN 60601 1 2006 Electric shock protection Type B Medical Devices Directive MDD Directive93 42 EEC Medical device class Waste Electrical and Electronic Equipment Directive WEEE Directive 2002 96 EC Please return the product for recycling 25 Your Endo Specialist Bedienungsanleitung f r HEROfill Obturatoren und Verifiers Klassifizierung Der HEROfill Obturator ist ein medizinisches Ger t der Klasse IIA und entspricht der Medizinproduktrichtlinie MDD Medical Device Directive 93 42 EG Der HEROfill Obturator ist ausschlie lich f r den professionellen zahnmedizinischen Gebrauch bestimmt Die Anweisungen bitte sorgf ltig lesen und befolgen Allgeme
37. r HEROfill Ofen kann den ganzen Tag lang eingeschaltet bleiben 2 Verwendung Wenn der Ofen betriebsbereit ist k nnen bis zu vier HEROfill Obturatoren gleichzeitig in die daf r vorgesehenen Schlitze gesteckt werden Die HEROfill Obturatoren in die mit den Zahlen 1 bis 4 gekennzeichneten Schlitze geben B3 Tipp Den Obturator der als erster verwendet werden soll im Schlitz Nr 1 platzieren den zweiten im Schlitz Nr 2 usw Generell sollte mit dem kleinsten HEROfill Obturator begonnen werden 33 MICRO MEGA Your Endo Specialist 1 Den Timer durch einen Druck auf das ON Icon aktivieren B4 2 W hrend des Erhitzungsprozesses leuchtet die Anzeige B rot auf 3 Ist die Verarbeitungstemperatur erreicht leuchtet die Anzeige gr n auf und ein akustisches Signal ert nt B4 Den HEROfill Obturator erst unmittelbar vor dem Einsetzen in den Wurzelkanal aus dem Erhitzer nehmen maximal 15 Minuten nach Ende der Erhitzungszeit 4 Durch eine 2 Sekunden lange Bet tigung der ON Taste kann der HEROfill Ofen ausgeschaltet werden B4 Ein dreimaliges akustisches Signal zeigt an dass der HEROfill Ofen ausgeschaltet ist Zum erneuten Einschalten des Erhitzers die ON Taste 2 Sekunden lang bet tigen Tipp Nach Beendigung der Behandlung muss der HEROfill Ofen nicht ausgeschaltet werden Das Ger t kann den ganzen Tag lang im Standby Modus bleiben 34 Your Endo Specialist Ton und Leuchtsignale D 3 Re
38. r Kunststoffstift des HEROfill Obturators hat eine geringe Konizit t Dies gew hrleistet einen angemessenen R ckfluss der erhitzten Guttapercha Der Stift ist 24 mm lang Der koronale Teil misst 6 mm und ist hohl Er enth lt den Metallstift Ein Gummistopper zeigt die Arbeitstiefe an Der Kunststoffstift und die Guttapercha sind r ntgendicht 2 Schritt f r Schritt Anleitung Sich idealerweise nach Anwendung der One Shape oder Revo S Methode zur Wurzelkanalaufbereitung und vor der Verwendung des HEROfill Obturators vergewissern dass folgende Voraussetzungen erf llt sind e Der Wurzelkanal ist korrekt gereinigt und gegl ttet der Schl ssel zu jeder erfolgreichen Wurzelkanalf llung e Der Wurzelkanal ist trocken e Die Arbeitsl nge wurde festgestellt Der Kunststoffstift ist biegsam genug um sich gekr mmten Wurzelkan len anzupassen Es wird dringend empfohlen rotierende Feilen mit einer gr eren Konizit t zu verwenden um eine ausreichende Erweiterung f r den HEROfill Obturator zu erreichen Wenn Feilen mit einer Konizit t von 2 benutzt werden sollte dies in Kombination mit Gates Glidden Bohrern Feilen zur Erweiterung des Kanaleingangs z B ENDOFLARE oder hnlichen Instrumenten erfolgen um eine ausreichende Erweiterung des Kanaleingangs im Koronalbereich zu gew hrleisten Die Benutzung von HEROfill Verifiers wird ebenfalls empfohlen SCHRITT 1 Bestimmung der Arbeitsl nge und Wahl der geeigneten HEROfill Obtu
39. ratorgr e Die Arbeitsl nge wird bis zum Apex 41 bestimmt Wir empfehlen die Arbeitsl nge ab dem oberen Wurzelkanalrand zu messen Die Arbeitsl nge kann mithilfe einer R ntgenaufnahme einer Feile oder eines elektronischen Apex Lokalisators festgestellt werden In der Regel entspricht die passende Gr e des HEROfill Obturators der Gr e der letzten am Apex verwendeten Feile Tipp Bei sehr engen und oder stark verkalkten Kan len kann es angebracht sein die Gr e unter der zuletzt am Apex verwendeten Feilengr e zu w hlen Wenn keine rotierenden Feilen mit einer Konizit t von 4 oder mehr verwendet werden sollte die L nge des gereinigten Wurzelkanals immer mit einem HEROfill Verifier berpr ft werden bevor der HEROFill Obturator eingef hrt wird 27 MICRO MEGA Your Endo Specialist Die Arbeitsl nge auf dem HEROfill Obturator markieren Wenn der HEROfill Verifier im apikalen Drittel eine leicht lose Passform hat wird der Gummistopper an der entsprechenden Arbeitsl nge platziert Anschlie end wird die Arbeitsl nge auf den HEROfill Obturator bertragen SCHRITT 2 Erhitzen des HEROfill Obturators Den ausgew hlten HEROfill Obturator in den HEROfill Ofen setzen und das Ger t starten A2 A3 N here Informationen zum Gebrauch des HEROfill Ofens auf Seite 31 SCHRITT 3 F llpaste eingeben Die Erhitzungszeit des HEROfill Obturators zum Mischen einer w rmebest ndigen F llpast
40. rds f r Wurzelkanalfeilen Zur d kompletten Obturation eines Wurzelkanals ist nur ein einziger HEROfill Obturator erforderlich I Das Ergebnis sollte immer eine perfekt platzierte Wurzelkanalf llung mit einer dichten apikalen Versiegelung sein Ka Der HEROfill Verifier ist ein unbeschichteter Stift mit denselben Abmessungen wie der Obturator Er dient zur berpr fung der ausgew hlten Obturatorgr e Der Schaft des Verifiers ist mit Markierungsringen f r Arbeitstiefen von 18 19 20 21 und 22 mm versehen Ein HEROfill Obturator besteht aus drei Teilen 1 Kunststoffgriff mit einem Metallstift 26 Your Endo Specialist Die Farbe des Kunststoffgriffs zeigt die Gr e des HEROfill Obturators an Unl sbar mit dem Griff verbunden ist ein 9 mm langer Metallstift aus Edelstahl Dieser Metallstift wird von einem 6 mm langen teilweise hohlen Kunststoffstift umschlossen Wenn der Metallstift entfernt wird hinterl sst er einen 6 mm langen Hohlraum im Kunststoffstift 2 Au enschicht aus thermoplastischer nat rlicher Guttapercha Die Guttapercha ist reversibel thermoplastisch Das bedeutet dass sie bei einer Erhitzung auf ber 100 C weich und stark haftend wird Bei Abk hlung wird sie wieder hart und fest Eine weitere Erhitzung macht die Guttapercha erneut weich und stark haftend 3 Kunststoffstift mit Stopper Der Kunststoffstift mit konischer Form ist biegsam genug um sich gekr mmten Wurzelkan len anzupassen De
41. tallique dans l me plastique Marquer la longueur de travail et suivre le processus de l tape 2 l tape 4 section 2 Stabiliser l me plastique avec des pr celles dentaires pendant que le manche la tige m tallique est retir e par torsion Tout mat riel exc dentaire sera enlev suivant les m thodes d crites en ETAPE 5 section 2 Emploi de ciment de scellement Comme pour toute autre technique d obturation un ciment de scellement sera d abord appliqu dans le canal lors de l utilisation du systeme HEROfill Il y a toutefois une diff rence significative l utilisation du systeme HEROfill exige l application d une tr s fine couche de ciment de scellement l aide d un HEROfill Verifier ou d une pointe de papier L utilisation d un condenseur n est pas recommand e puisqu elle a tendance appliquer une quantit trop importante de ciment de scellement sur les parois canalaires Penser appliquer seulement une tr s fine couche de ciment de scellement 4 Pr paration d un logement pour tenon radiculaire Un logement pour tenon radiculaire peut tre cr en enlevant la partie coronaire de obturation L ame plastique perc e sur 6 mm facilite grandement cette pr paration compar e aux obturateurs avec une me solide Les fraises rondes lisses de pr f rence un polissoir rond sans lames coupantes sont privil gier car ils ne coupent pas mais au contraire ramollissent la gutta per
42. ument e de mani re satisfaisante enlever l obturateur HEROfill 1 Description Un obturateur HEROfill est compos d une me en plastique recouverte de gutta percha thermoplastique Il est disponible en diff rentes dimensions de 20 45 conform ment la norme ISO L obturateur HEROfill correspond la norme ISO pour les instruments canalaires Un seul obturateur HEROfill est suffisant pour l obturation compl te d un canal Le r sultat doit toujours tre une obturation canalaire parfaitement plac e avec un scellement apical tanche Le HEROfill Verifier est compos d une me plastique non recouverte de gutta Y percha dont les dimensions sont identiques celles de l obturateur ll permet de v rifier que le num ro de l obturateur choisi convient ll est possible de mesurer la longueur de travail gr ce des rep res circulaires 18 19 20 21 et 22 mm L obturateur HEROfill se compose de trois parties 1 Un manche plastique dans lequel est ins r e une tige m tallique Le manche plastique porte un code couleur en fonction du num ro de l obturateur La tige en acier inox de 9 mm de long est solidaire du manche plastique La tige m tallique est ins r e 6 mm dans l me plastique Si la tige m tallique est retir e de l me plastique elle laisse un creux de 6 mm dans l me plastique Your Endo Specialist 2 Une couche ext rieure de gutta percha thermoplastique nature
43. v e lectrique externe Avertissement Eviter tout contact avec l int rieur de la chambre de r chauffage avant que le r chauffeur n ait compl tement refroidi Sp cifications techniques ALIMENTATION ELECTRIQUE Alimentation d entr e 100 240V AC 50 60Hz Alimentation de sortie 9V DC 1 7A SECURITE Arr t automatique Le r chauffeur s eteint automatiquement apr s 9 heures Temps de chauffe Le temps de chauffe du r chauffeur HEROfill est de 60 secondes Le pr chauffage est compris entre 3 4 minutes selon la temp rature ambiante Your Endo Specialist 1 D marrage du r chauffeur 1 Brancher le fil d alimentation la prise d alimentation DC du r chauffeur et au secteur et mettre en marche l appareil B1 2 Une lumi re rouge s allume A indiquant que le r chauffeur HEROfill est en pr chauffage B2 La lumi re devient verte avec un signal sonore lorsque le r chauffeur est pr t tre utilis Note Le r chauffeur HEROfill peut rester allum toute la journ e 2 Utilisation Quand le r chauffeur est pr t tre utilis placer jusqu 4 obturateurs HEROfill dans les encoches marqu es 1 4 sur le dessus de l appareil B3 Astuce Placer l obturateur HEROfill qui sera utilis en premier dans l encoche 1 le second dans le 2 etc g n ralement vous devriez commencer avec le plus petit obturateur HEROfill Your Endo Specialist 1 Activer la m