Bedienungsanleitung de testo 205 pH-/Temperatur
Contents
1. batteries 4x Type LR44 Watch out for 00 lt 3 Reinsert battery compartment 12 7 Questions and Answers 7 Questions and Answers Question Possible causes Possible solution Readings instable Static charge Air cushion from measurement electrode gets into measurement tip pH electrode has dried out gt gt gt Rinse off pH electrode with tap water or low concentration soap water Shake pH electrode downward direction like with a fever thermometer Place pH electrode for several hours in water or diluted hydrochloric acid TF lights up Remaining capacity of battery gt Change battery See lt 1 6 4 Changing battery 11 Instrument switches Auto Off function is switched on Auto Off itself off See 5 2 Setting instrument P 8 1 lights up Invalid gradient value gt Recalibrate instrument of pH electrode a new buffer solution could be used pH electrode defective P Change probe Er2 lights up Invalid offset value gt Recalibrate instrument of the pH electrode a new buffer solution could be used pH electrode defective gt Change probe Er3 lights up Invalid gradient value gt Recalibrate instrument of pH electrode following a new buffer solution 3 point calibration could be used pH electrode defective gt Change probe EA lights up Probe not inserted correctly gt Check connection pH electrode defective gt C
2. abgeben gt Produkt nach Ende der Nutzungszeit direkt an Testo senden Wir sorgen f r eine umweltschonende Entsorgung 2 Bestimmungsgem e Verwendung 5 2 Bestimmungsgem e Verwendung 8 Das testo 205 ist handliches Messgerat zur Messung von pH Wert und Temperatur Einsatzbereiche sind die Messung von halbfesten Medien in der Lebensmittelherstellung und bearbeitung Schlachth user Zerlegebetriebe Wareneingangskontrolle bei Transporten K seherstellung B ckereibetriebe Das testo 205 ist nicht f r diagnostische Messungen im medizinischen Bereich geeignet 6 3 Produktbeschreibung 3 Produktbeschreibung 3 1 Anzeige und Bedienelemente ON HOLD Ein Ausschalten Messwerte halten Sondenfassung mit Schraubring MODE Funktion wechseln CAL Modus Kalibrierung aufrufen Batteriefach 3 2 Spannungsversorgung Die Spannungsversorgung erfolgt ber vier Knopfzellen Typ LR44 im Lieferumfang 8 Produktbeschreibung 7 3 3 Aufbewahrungskappe Die mit Elektrolyt Gel gef llte Aufbe wahrungskappe dient zur Lagerung der Sonde zwischen den Messungen Die Sonde ist nur bei Lagerung im Elektrolyt Gel sofort einsatzbereit Befand sich die Sonde f r l ngere Zeit au erhalb des Elektrolyt Gels muss sie f r ca 12h wieder in Elektrolyt Gel gelagert werden um sich zu regenerieren Die Aufbewahrungkappe kann auch auf die Wand Transport halterung aufgesteck
3. during transport cheese production and in bakeries testo 205 is not suitable for diagnostic measurements in the medical sector 6 3 Product Description 3 Product Description 3 1 Display and control elements Display ON HOLD On Off switch holds readings Probe socket with screw ring MODE change function CAL Calls up calibration mode Battery comparment 3 2 Power Power is via four button cells LR44 included with delivery 8 Product Description 7 3 3 Storage cap The storage cap filled with electrolyte gel is used to store the probe between measurements The probe is only immediately ready to operate if stored in electrolyte gel If the probe has been out of the electrolyte gel for a longer period of time it must be stored in the electrolyte gel for approx 12 hours to regenerate The storage cap can also be attached to the wall transport bracket 3 4 Wall Transport bracket The wall transport bracket with belt holder N and attachment unit for the storage cap is J used for the safe storage of the measurement instrument at a fixed point or during transport 4 Initial Operation Insert battery _ 1 Remove battery compartment keri 2 Insert batteries 4 LR44 Watch out for SIN o lt a 3 Push battery compartment back in 4 Remove protection strip on the storage cap 8 5 Operation 5 Operation 5 1
4. E Switch Hold on On or off OFF CAL Confirm selection MODE The gradient and offset values stored in the instrument are displayed as information Change view MODE 5 Operation 9 5 Select calibration method 1P 2P CAL Confirm selection MODE If 1 or 2 point calibration has been set gt Select calibration points 4 7 or 10 and 4 7 or 7 10 CAL Confirm selection MODE 6 Switch Auto Off on On or off OFF CAL Confirm selection MODE 7 Display light on On or off OFF CAL Confirm selection MODE 8 Switch beeper on On or off OFF CAL Confirm selection and save settings MODE All of the segments light up briefly and the instrument changes to the measurement mode 5 3 Measuring Setting up the instrument large quantities of the electrolyte gel are stuck to the probe when removed from the storage cap it is a sign that the gel is spent gt Anew storage cap is needed gt Clean off the pH probe before and after each measurement with low concentration soap water followed by tap water water temperature should be below 40 C Dab dry with a paper towel Do not rub 1 Carefully remove storage cap 2 Switch on instrument ONHOLD Carry out measurement Measurement tip made of glass risk of breakage Risk of injury on account of glass parts which remain in the measurement medium gt Check measurement tip of pH probe after each measur
5. Stunden in Wasser oder verdiinnte Salzsaure stellen T leuchtet Restkapazit t der Batterie gt Batterie wechseln siehe lt 10h 6 4 Batterie wechseln 8 11 Gerat schaltet selbstandig Funktion Auto Off eingeschaltet Auto Off ausschalten aus siehe 5 2 Gerat einstellen S 8 Er1 leuchtet Ungiiltiger Steigungswert gt Ger t neu kalibrieren der pH Elektrode evtl neue Pufferl sung verwenden pH Elektrode defekt gt Sonde austauschen Er2 leuchtet Ung ltiger Offsetwert gt Ger t neu kalibrieren der pH Elektrode evtl neue Pufferl sung verwenden pH Elektrode defekt gt Sonde austauschen Er3 leuchtet Ung ltiger Steigungswert gt Ger t neu kalibrieren der pH Elektrode nach evtl neue Pufferl sung 3 Punkt Kalibrierung verwenden pH Elektrode defekt gt Sonde austauschen Er4 leuchtet Sonde nicht korrekt gesteckt b Verbindung pr fen pH Elektrode defekt gt Sonde austauschen Fall wir Ihre Frage nicht beantworten konnten wenden Sie sich bitte an Ihren H ndler oder den Testo Kundendienst Kontakt daten finden Sie im Garantieheft oder im Internet unter www testo com 8 Technische Daten 13 8 Technische Daten Eigenschaft Werte Messgr en pH C Messwertaufnehmer pH Elektrode NTC Messbereich 0 14pH 0 60 kurzfristig bis 80 C max 5min Aufl sung 0 01pH 0 1 C Genauigkeit 0 02pH 0 4 C Tempera
6. Switching on off gt gt Switch on instrument CONHOLD All segments light up briefly and the instrument changes to the measurement mode Switch off instrument Keep pressed 5 2 Setting instrument The following functions can be set Function Description Setting options Temperature unit Sets unit C or F Auto Hold AUTO HOLD Automatically holds reading On switched on or as soon as it is stable OFF switched off Gradient Offset Displays gradient and offset None values stored in the instrument Information only Calibration method CAL Sets 1 2 or 3 point 1P 2P or 3P calibration Calibration points CAL pH Sets calibration points 1P 4 7 or 10 2P 47 07710 Auto Off AUTO OFF Instrument switches off On switched on or automatically after 10 minutes OFF switched off if no button has been pressed Display light bl Display light goes on for On switched on or approx 3 s whenever a OFF switched off button is activated Beeper bP Warning sound button pressed On switched on or stable reading reached with OFF switched off Auto Hold function switched on Modification less than 0 02pH in 20s The setting procedure can be interrupted by switching off the instrument The modifications are then not saved The instrument is switched off 1 2 Opening the setting mode is kept pressed CONHOLD Select temperature unit C or F CAL Confirm selection MOD
7. afety Information IN Avoid electrical hazards gt Do measure on or near live parts Preserving product safety warranty claims gt Operate the instrument properly and according to its intended purpose and within the parameters specified Do not use force gt Do not store together with solvents e g acetone gt Temperature data on probes sensors refer only to the measurement area of the sensors Do not expose handles and cables to temperatures greater than 70 C if they are not specifically designed for higher temperatures gt Open the instrument only when this is expressly described in the documentation for maintenance purposes gt Only the maintenance and service work described in the documentation should be carried out Please adhere to the steps specified For safety reasons only original spare parts from Testo should be used ay bd Ensure correct disposal gt Disposal of defective rechargeable batteries and spent batteries at the collection points provided gt Send the instrument directly to us at the end of its life cycle We will ensure that it is disposed of in an environmentally friendly manner 2 Intended Purpose 5 2 Intended Purpose testo 205 is a practical instrument for measuring value and temperature Its appliclation areas include the measurement of semi solid substances in the food production and processing sector abattoirs cutting plants Incoming goods checks
8. alten gedr ckt halten 2 pH Sonde mit Leitungswasser oder gering konzentrierter Seifenlauge Wassertemperatur unter 40 C absp len und mit einem Papiertuch trocken tupfen nicht reiben Sonde in die mit Elektrolyt Gel gef llte Aufbewahrungkappe stecken Die Sondenspitze muss in das Elektrolyt Gel eingetaucht sein a Elektrolyt Gel sauber halten 5 4 Ger t kalibrieren Beachten Sie auch die Anwendungshinweise die der Puffer a l sung beiliegen Testo Puffer siehe Etikett Das Ger t ist eingeschaltet und befindet sich im Messmodus 1 Kalibriermodus ffnen CAL Kalibrierpunkt 4 7 oder 10 wird angezeigt und CAL blinkt 2 Kalibrierpunkt berspringen oder Sonde in die Pufferl sung eintauchen und Kalibrierung starten CAL Das Ger t wartet auf einen stabilen Messwert AUTO blinkt st ein stabiler Messwert vorhanden nderung geringer 0 02pH in 20s wird der Kalibrierpunkt kalibriert und das Ger t wechselt zum n chsten Kalibrierpunkt falls vor handen bzw zur Anzeige des Steigungs und Offsetwerts gt Kalibrierung manuell durchf hren CAL 5 Bedienung 11 gt Handlungsschritt 2 f r die weiteren Kalibrierpunkte wiederholen Nach Abschluss der Kalibrierung wird der Betrag des Steigungs und Offsetwerts angezeigt Ist der Betrag des Steigungswerts kleiner als 50mV pH oder der Betrag des Offsetwerts gr er als 60mV ist die pH Elektrode verbraucht und sollte ausgetauscht w
9. and take the if the precautionary measures precautionary measures specified are not taken specified Warning Warning text Caution Please read warning Light physical injuries could occur carefully and take the if the precautionary measures precautionary measures specified are not taken specified Caution 1 Note Pay particular attention to Notes Button name Press button Text Display content Text or symbol is shown on the display Contents 3 Contents General Information CONTEM Si 1 Safety Information sana ss 2 Intended Purpose rrura 3 Product Description 6 3 1 Display and control elements 6 3 2 Power 3 3 Storage cap ed 3 4 Wall Transport bracket rr T 4 Initial Operatien EO 7 OPAO Ea 8 5 1 Switching OMO ta e ai 8 8 2 Setting Instrument neuen nenne 8 5 3 Measuring 9 5 4 Calibrating instrument IO 6 Service and 11 8 1 Checking gb gel aunis aen 11 8 2 Cleaning 11 8 3 eurae Medea aA 11 OA Changingibatteny uima t ahtaissa na 11 7 Questions and a a n nannaa 12 8 Technical data 18 9 Accessories and Spare 13 4 1 Safety Information 1 S
10. ement for damage Warning 10 5 Operation gt Immerse penetrate probe in the medium to be measured The measured and temperature values are displayed The readings are updated twice a second gt Hold readings manually ONHOLD gt Restart measurement I Auto Hold is switched on AUTO HOLD flashes until the instrument has found a stable pH reading The readings are then frozen AUTO HOLD lights up If no stable pH readings have been found within 300s the measurement is stopped O and AUTO HOLD light up gt Restart measurement ONHOLD Finish measurement 1 2 Switch off instrument Keep pressed Clean off the pH probe with low concentration soap water followed by tap water water temperature should be below 40 C Dab dry with a paper towel Do not rub 3 Insert probe in the storage cap filled with electrolyte gel The probe tip must be immersed in the electrolyte gel Keep electrolyte gel clean 5 4 Calibrating instrument Please also adhere to the instructions supplied with the buffer solution Testo buffer see label The instrument is switched on and is in the measurement mode 1 2 Open calibration mode CAL Calibration point 4 7 or 10 is shown and CAL flashes Skip calibration point MODE Or Immerse probe in the buffer solution and start calibration 4 The instrument waites for a stable reading AUTO flashes stable reading
11. erden 3 Zur ck zur Messansicht Beliebige Taste dr cken 6 Wartung und Pflege 6 1 Elektrolyt Gel pr fen gt Elektrolyt Gel der Aufbewahrungskappe regelm ig auf Verunreinigungen und ausreichenden F llstand pr fen Bei Bedarf Aufbewahrungskappe erneuern 6 2 Geh use reinigen gt Geh use bei Verschmutzung mit einem feuchten Tuch Seifenlauge reinigen Keine scharfen Reinigungs oder L sungsmittel verwenden 6 3 Sonde wechseln Nach einem Sondenwechsel muss das Ger t neu kalibriert werden siehe 5 4 Ger t kalibrieren S 10 Ger t muss ausgeschaltet sein Steckerkontakte am Ger t d rfen nicht ber hrt werden 1 Schraubring gegen den Uhrzeigersinn drehen und Sonde abziehen 2 Neue Sonde aufstecken F hrungsnuten beachten und Schraubring im Uhrzeigersinn festdrehen 6 4 Batterie wechseln gt m 1 Batteriefach herausziehen 1 2 Leere Batterien herausnehmen und GUK neue Batterien 4x Typ LR44 einsetzen Polung beachten 3 Batteriefach einschieben 12 7 Fragen und A ntworten 7 Fragen und Antworten Frage M gliche Ursachen M gliche L sung Messwerte instabil Statische Aufladung gt pH Elektrode mit Leitungswasser oder gering konzentrierter Seifenlauge abspiilen Luftpolster der Messelektrode b pH Elektrode wie ein ist in die Messspitze gelangt Fieberthermometer nach unten ausschitteln pH Elektrode eingetrocknet gt pH Elektrode f r einige
12. halten zusenden ernennen 8 8 2 Eate 8 5 3 Messen 9 5 4 Ger t kalibrieren IO 6 Wartung alaena KA 11 6 1 Elektrotyt Gel alata EAE 11 6 2 Geh ussrehgen enara 11 BS Sonde eena aA 11 OA Be para 11 erabide Bauer 12 8 Technische Daten 13 9 Zubeh r und EGOZ 13 4 1 Sicherheitshinweise 1 Sicherheitshinweise Elektrische Gefahren vermeiden gt Nicht an oder der Nahe von spannungsf hrenden Teilen messen Produktsicherheit Gew hrleistungsanspr che wahren gt Nur sach und bestimmungsgem und unter Einhaltung der vorgegebenen Parameter einsetzen Keine Gewalt anwenden gt Nicht zusammen mit L sungsmitteln z Aceton lagern gt Temperaturangaben auf Sonden F hlern beziehen sich nur auf den Messbereich der Sensorik Handgriffe und Zuleitungen keinen Temperaturen Uber 70 C aussetzen wenn diese nicht ausdr cklich f r h here Temperaturen zugelassen sind gt Produkt nur ffnen wenn dies zu Wartungs oder Instand haltungsarbeiten ausdr cklich in der Dokumentation beschrie ben ist gt Nur Wartungs und Instandhaltungsarbeiten durchf hren die der Dokumentation beschrieben sind Dabei an die vorge gebenen Handlungsschritte halten Aus Sicherheitsgr nden nur Original Ersatzteile von Testo verwenden Fachgerecht entsorgen gt Defekte Akkus leere Batterien an den daf r vorgesehenen Sammelstellen
13. hange probe If we have not answered your question please contact your nearest distributor or Testo Customer Service point Contact details can be found in the Warranty booklet and in Internet at www testo com 8 Technical data 13 8 Technical data Feature Values Parameters pH C 5 Sensor pH electrodes NTC Measurement range 0 to 14pH 0 to 60 C short term to 80 C max 5min Resolution 0 01pH 0 1 C Accuracy 0 02pH 0 4 C Temperature compensation Automatic Probe Probe module Measuring rate 2 s Operating temperature 0 to 50 C Storage temperature 20 to 70 C Power 4x button cell Type LR44 Battery life Approx 80h Housing ABS Protection class IP65 CE guideline 89 336 EEC Dimensions Ixwxh 145 x 38 x 167 Warranty 2 years excluding probe module 9 Accessories and Spare Parts Name Item no Probe module incl storage cap with electrolyte gel 0650 2051 Storage cap 205 with electrolyte gel 1 off 0554 2051 Storage cap 205 with electrolyte gel 3 off 0554 2052 pH buffer solution 4 01pH 250ml 1 off 0554 2061 pH buffer solution 4 01pH 250ml 3 off 0554 2062 pH buffer solution 7 00pH 250ml 1 off 0554 2063 pH buffer solution 7 00pH 250ml 3 off 0554 2064 pH buffer solution 10 01pH 250ml 1 off 0554 2065 pH buffer solution 10 01pH 250ml 3 off 0554 2066 Aluminium case 0554 2069 te
14. is available change less than 0 02pH in 20s the calibration point calibrates and the instrument changes to the next calibration point if available or to the gradient and offset value display gt Carry out calibration manually CAL gt Repeat Step 2 for additional calibration points 5 Operation 11 Once calibration is complete the amount of the gradient and offset value is shown If the amount of the gradient value is less than 50mV pH or the amount of the offset value is greater than the pH electrode is spent and must be replaced 3 Return to measurement view Press any button 6 Service and Maintenance 6 1 Checking electrolyte gel gt Check the electrolyte gel in the storage cap regularly for contamination and ensure it is filled to the correct level Replace storage cap if necessary 6 2 Cleaning housing gt Clean housing with a damp cloth soap water if dirty Do not use abrasive cleaning agents or solutions 6 3 Changing the probe The instrument must be newly calibrated once a probe has been changed See 5 4 Calibrating instrument 10 Instrument must be switched off Plug contacts in the instrument should not be touched 1 Turn screw ring anti clockwise and remove probe 2 Attach new probe watch for guide groove and tighten screw ring in a clockwise direction 6 4 Changing battery 1 Pull out battery compartment 1 ET 2 Remove spent batteries and insert new
15. kurz auf und das Ger t wechselt in den Messmodus 5 3 Messen Ger t vorbereiten 1 2 Bleiben beim Herausziehen der Sonde aus der Aufbe wahrungskappe gr ere Mengen Elektrolyt Gel an der Sonde haften ist dies ein Zeichen daf r dass das Gel verbraucht ist gt Aufbewahrungskappe erneuern gt pH Sonde vor und nach jeder Messung mit gering konzen trierter Seifenlauge und anschlie end mit Leitungswasser absp len Wassertemperatur unter 40 C Mit einem Papiertuch trocken tupfen nicht reiben Aufbewahrungskappe vorsichtig abziehen Ger t einschalten Messung durchf hren Messspitze aus Glas Bruchgefahr Verletzungsgefahr durch Glasteile die im Messmedium Warnung zur ckbleiben Messspitze der pH Sonde nach jeder Messung auf Besch digungen pr fen 10 5 Bedienung gt Sonde in das zu messende Medium eintauchen einstechen Die gemessenen pH und Temperaturwerte werden angezeigt Die Messwerte werden zweimal pro Sekunde aktualisiert gt Messwerte manuell halten ON HOLD gt Messung erneut starten ONHOLD Ist Auto Hold eingeschaltet blinkt AUTO HOLD bis das Ger t einen stabilen pH Messwert gefunden hat Die Messwerte werden dann gehalten AUTO HOLD leuchtet Wird innerhalb von 300s kein stabiler pH Messwert gefunden wird die Messung abgebrochen und AUTO HOLD leuchten gt Messung erneut starten ONHOLD Messung beenden 1 Ger t aussch
16. schaltet oder OFF ausgeschaltet Displaybeleuchtung bl Displaybeleuchtung bei jeder Tastenbetatigung fiir ca 3s einschalten On eingeschaltet oder OFF ausgeschaltet Beeper bP Hinweiston Tastenbest tigung stabiler Messwert erreicht bei eingeschalteter Auto Hold Funktion On eingeschaltet oder OFF ausgeschaltet nderung geringer 0 02pH in 20s Der Einstellvorgang kann durch Ausschalten des Ger tes werden dann nicht gespeichert Das Ger t ist ausgeschaltet 1 Einstellmodus ffnen gedr ckt halten ONHOLD 2 Temperatureinheit C oder F w hlen CAL Auswahl best tigen MODE 3 Auto Hold ein On oder ausschalten OFF CAL Auswahl best tigen MODE Die im Ger t hinterlegten Steigungs und Offsetwerte werden zur Information angezeigt abgebrochen werden Die vorgenommenen nderungen 5 Bedienung 9 Ansicht wechseln MODE Kalibriermethode 1P 2P oder w hlen CAL Auswahl best tigen MODE Wenn 1 oder 2 Punkt Kalibrierung eingestellt wurde Kalibrierpunkte 4 7 oder 10 bzw 4 7 oder 7 10 w hlen CAL Auswahl best tigen MODE Auto Off ein On oder ausschalten OFF CAL Auswahl best tigen MODE Displaybeleuchtung ein On oder ausschalten OFF CAL Auswahl best tigen MODE Beeper ein On oder ausschalten OFF CAL Auswahl best tigen und Einstellungen speichern MODE Alle Segmente leuchten
17. sto AG Postfach 1140 79849 Lenzkirch Testo Stra e 1 79853 Lenzkirch Telefon 07653 681 0 Fax 07653 681 100 E Mail info testo de Internet http www testo com 0973 2051 01 Sky dr 30 03 2004
18. t werden 3 4 Wand Transporthalterung Die Wand Transporthalterung mit Gurtel N halter und Aufsteckvorrichtung f r die EN Aufbewahrungskappe dient zur sicheren Aufbewahrung des Messgerats an einem festen Platz oder beim Transport 4 Inbetriebnahme Batterie einlegen lt gt 1 Batteriefach herausziehen ET 2 Batterien 4x Typ LR44 einsetzen edi Polung beachten Tr 3 Batteriefach einschieben 4 Schutzstreifen an der Oberseite der Aufbewahrungkappe abziehen 8 5 Bedienung 5 Bedienung 5 1 Ein Ausschalten gt Ger t einschalten CONHOLD Alle Segmente leuchten kurz auf und das Ger t wechselt in den Messmodus gt Ger t ausschalten gedr ckt halten 5 2 Ger t einstellen Folgende Funktionen k nnen eingestellt werden Funktion Beschreibung Einstellm glichkeiten Temperatureinheit Einheit einstellen C oder F Auto Hold AUTO HOLD Messwert automatisch halten eingeschaltet oder sobald dieser stabil ist OFF ausgeschaltet Steigung Offset Anzeige der im Ger t hinter keine legten Steigungs und Offset werte Betrag nur Information Kalibriermethode CAL 1 2 oder 3 Punkt Kalibrierung einstellen 1P 2P oder 3P Kalibrierpunkte CAL pH Kalibrierpunkte einstellen 1P 4 7 oder 10 2P 47 oder 710 Auto Off AUTO OFF Ger t schaltet nach10min ohne Tastenbet tigung selbst ndig aus On einge
19. testo 205 pH Temperatur Messgerat 2 Allgemeine Hinweise Allgemeine Hinweise Lesen Sie dieses Dokument aufmerksam durch und machen Sie sich mit der Bedienung des Produkts vertraut bevor Sie es ein setzen Bewahren Sie dieses Dokument griffbereit auf um bei Bedarf nachschlagen zu k nnen Kennzeichnungen Darstellung Bedeutung Bemerkungen Warnhinweis Warnung Warnhinweis aufmerksam Schwere K rperverletzungen k nnen eintreten wenn die genannten Vorsichtsma nahmen lesen und die genannten Vorsichtsma nahmen treffen nicht getroffen werden Warnung Warnhinweis Vorsicht Warnhinweis aufmerksam Leichte K rperverletzungen oder Sachsch den lesen und die genannten k nnen eintreten wenn die genannten Vor Vorsichtsma nahmen treffen sichtsma nahmen nicht getroffen werden Vorsicht 1 Hinweis Hinweise besonders beachten Tastenbezeichnung Taste driicken Text ZA _Displayinhalt Textbzw Symbol wird auf dem Display angezeigt Inhalt 3 Inhalt Allgemeine Hinweise 1 SicherheltShinweise ana 4 2 Bestimmungsgem e Verwendung 5 Produktbeschreibung 6 3 1 Anzeige und Bedienelemente 6 3 2 Spannungsversorgung 3 3 Aufbewahrungskappe ed 3 4 Wand Transporthalterung rrura T 4 Inbetriebnahme sasinen 7 BEdIENUNg rende anne een ner 8 Aussc
20. turkompensation automatisch F hler Sondenmodul Messrate 2 s Betriebstemperatur 0 50 C Lagertemperatur 20 70 C Spannungsversorgung 4x Knopfzelle Typ LR44 Batteriestandzeit ca 80h Geh use ABS Schutzart IP65 CE Richtlinie 89 336 EWG Abmessungen LxBxH 145 x 38 x 167 Garantie 2 Jahre ausgenommen Sondenmodule 9 Zubeh r und Ersatzteile Bezeichnung Artikel Nr Sonden Modul inkl Aufbewahrungskappe mit Elektrolyt Gel 0650 2051 Aufbewahrungskappe 205 mit Elektrolyt Gel 1 St ck 0554 2051 Aufbewahrungskappe 205 mit Elektrolyt Gel 3 St ck 0554 2052 pH Pufferl sung 4 01pH 250ml 1 St ck 0554 2061 pH Pufferl sung 4 01pH 250ml 3 St ck 0554 2062 pH Pufferl sung 7 00pH 250ml 1 St ck 0554 2063 pH Pufferl sung 7 00pH 250ml 3 St ck 0554 2064 pH Pufferl sung 10 01pH 250ml 1 St ck 0554 2065 pH Pufferl sung 10 01pH 250ml 3 St ck 0554 2066 Alukoffer 0554 2069 14 Notizen testo 205 pH Temperature Measuring Instrument 2 General Information General Information Please read this document through carefully and familiarise yourself with the operation of the product before putting it to use Keep this documentation to hand so that you can refer to it when necessary Symbols and what they mean Symbol Meaning Remarks Warning text Warning Please read warning Serious physical injuries could occur carefully