Contents
1. Series Option Nivotemp NT MD OV oval flange G1 Adapteron G1 Material 2T MS LED Temperature display 2 x Temperature output Connector 4T 2M12 LED Temperature display 4x Temperature output 1T KT LED Temperature display 1x Temperature output Length 1 xAnalog output max 500 mm Switch function 2 contact NO open atlow level level contacts NC closed at low level MER eus Position L2 mm notadjustable 2 level contact Switch function 1 contact Position L1 mm NO open atlow level 1 level contact NC closed at low level 1 1 Range of Use A medium temperature between 20 C and 80 C 4 F and 176 F must be kept The level switch must not be used with highly flammable or corrosive fluids The fluid must not contain particles especially metallic particles to avoid accumulation between float and immersion pipe If necessary install a filter All devices are designed for industrial application only They are not applicable as safety components The level switches MUST NOT be applied in areas where the breakdown or by malfunction will affect safety and health of persons The device is NOT applicable for hazardous areas BX100022 02 2010 Art Nr 90 32 035 25 Bedienungs und Installationsanleitung Installation and Operation Instruction a Nivotemp NT MD e PU FIMERA TECHNOLOGIES 1 2 Functional Description 1 2 1 Level Control The measuring
2. 5 4 Aufbauen und Anschlie en aaa 7 A Betriebes rarai aara aaa a Nea a E a a aa eaa a aaaea aaa ENa 8 4 1 Einschalten nennen naeh 8 4 2 LED Statusanzeigen 2444s4snnennnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnennnnnnnnnnnnnnnsnnnnnnnsnnnnnnnsnnnnnnnsnnnnn nn 8 4 3 Allgemeine Tastenfunktionen c cccccccccceceeccceeeeeneceeeeeeceeeenenecehenececeeesenedenesececeheneaceeteneceaeeeseaecenenes 9 4 4 Aktive Tastensperre R nn 10 4 5 Mena bersichl air nieht 10 4 6 ndern der Basiseinstellungen ueeeenenenenennnnnnnnnnnenenennnnnnnnnnennenennnnnnnnnne nennen 12 4 6 1 Einheit Temperatur festlegen 242440444444H04Hnnnannnnnnnnnnannnnnnnansnnnnnannnnnnnannnnnnnannnnnnnann een 12 4 6 2 Aktualisierungsrate der Anzeige einstellen uusnnnnnnnnennnnnnnennnnnnnennnnnnnnnnnnnnn mann 12 4 6 3 Tastensperre aktivieren deaktivieren 4444440onsnnnnennnnnnnnennnnnnnnnnnnnnnennnnrnnennennnen nn 13 4 6 4 Werkseinstellungen wieder herstellen Reset 13 4 7 Irc antl E tase eitaa etal 14 4 7 1 Schaltausgang x Definition der Schaltcharakteristik seee 15 4 7 2 Schaltausgang x Obere Schaltgrenze Einschaltpunkt ssseeee 16 4 7 3 Schaltausgang x Untere Schaltgrenze R ckschaltpunkt sseeee 16 4 7 4 Schaltausgang x Einschaltv
3. Problem St rung m gliche Ursache Abhilfe keine Anzeige Keine Versorgungsspannung Kabel pr fen und ggf austauschen Fehlermeldungen im Display Wechsel zwischen Err und Exxx z B E rr e E HH p l E D D Umgebungstemperatur zu niedrig Grenzwerte einhalten Error 01 E B D c Umgebungstemperatur zu hoch Grenzwerte einhalten Error 02 t D D u Pt 100 defekt Kurzschluss Ger t zur Reparatur einsenden L 7 Error 04 E p D H Pt 100 defekt Kabelbruch Ger t zur Reparatur einsenden Error 08 6 Entsorgung Bei der Entsorgung sind die gesetzlichen Vorschriften des Anwenderlandes zu beachten insbesondere die Vorschriften f r die Entsorgung von elektronischen Bauteilen 24 BX100022 02 2010 Art Nr 90 32 035 Bedienungs und Installationsanleitung Installation and Operation Instruction A af Nivotemp NT MD 4277 LaF TECHNOLOGIES 1 Introduction The series of level switches Nivotemp NT MD are suitable for monitoring level and temperature in tanks in fluid systems Depending on the model the level switches are equipped with a different number switching outputs The following options are available e OV oval flange e G1 Adapter to G1 flange Please find the configuration on the type plate Here you find the acknowledgement number the product key and the model description NT MD 2M12
4. Messgr e ____ gt Analog OutX Z5 gt Analog MaxX A H Wahlmen Hauptmen Messgr e Einstellmen Analog X N Zuweisung Maximalwert f gt LoLo ahi 3 H LH Hinweis Einstellbereich Der eingestellte Ausgabebereich darf nicht kleiner als 10 des 0 C bis 100 C Messbereichs gew hlt werden A tH A ILo gt 10 32 F bis 212 F Beizu klein gew hltem Bereich kann es sein dass die Analogwertausgabe Stufen aufweist 4 8 2 Analogausgang x Zuweisung der unteren Grenze Hier erfolgt die Zuweisung bei welcher Temperatur das minimale Analogsignal ausgegeben werden soll Die Einstellung erfolgt im Men Analog OutX An_ gt Einstellmen Analog X Messgr e ____ gt Hauptmen Messgr e A IL Q Hinweis Der eingestellte Ausgabebereich darf nicht kleiner sein als 10 des Analog MinX F Lo Wahlmen Zuweisung Minimalwert Colo ahi 3 gt a Messbereichs gew hlt werden A H A ILo gt 10 is i l 32 F bis 212 F Bei zu klein gew hltem Bereich kann es sein dass die Analogwertausgabe Stufen aufweist 4 8 3 Analogausgang x Festlegen der Signalform Der Analogausgang kann als Spannungs oder Stromausgang mit unterschiedlichen Wertebereichen definiert werden Die Einstellung erfolgt im Men Messgr e gt Analog OutX An_
5. Stellen Sie die gew nschte Verz gerung ein dt Einstellbereich 0 100 Sekunden BX100022 02 2010 Art Nr 90 32 035 23 Bedienungs und Installationsanleitung Installation and Operation Instruction v Nivotemp NT MD 427 ay TECHNOLOGIES 5 Wartung Das Ger t arbeitet wartungsfrei 5 1 Service und Reparatur Risiko durch fehlerhaftes Ger t Schalten Sie das Ger t aus und trennen Sie es vom Netz Beheben Sie St rungen am Ger t umgehend Das Ger t darf bis zur Beseitigung der St rung nicht mehr in Betrieb genommen werden Sollte ein Fehler beim Betrieb auftreten finden Sie in der folgenden Tabelle Hinweise f r die Fehlersuche und Beseitigung Sollten Sie Fragen haben wenden Sie sich bitte an unseren Service Tel 49 0 2102 498955 oder Ihre zust ndige Vertretung Halten Sie dazu bitte die Daten des Typenschildes bereit Ist nach Beseitigung eventueller St rungen und nach Einschalten der Netzspannung die korrekte Funktion nicht gegeben muss das Ger t durch den Hersteller berpr ft werden Bitte senden Sie das Ger t zu diesem Zweck in geeigneter Verpackung an B hler Technologies GmbH Reparatur Service Harkortstra e 29 40880 Ratingen Deutschland 5 2 Fehlerbehebung Im Fehlerfall werden alle Ausg nge spannungslos geschaltet Die vier LEDs blinken Fehler bleiben bis zum Ausschalten im Ger t gespeichert
6. Reset rE5 resets the factory settings All custom made changes are lost Since the limits are reset as well all settings for level and temperature must be checked Basic EF 5 y Reset FES gt Confirm Sr Basic ext functions Factory settings na YES The following options are available 7 6 5 no BEG No reset Do reset keeps the actual settings the settings are reset to factory settings The factory settings are set as follows Definitions SP IrPx Set point reset point x d5x drx Delay for setting resetting switching output x Rx H AX La maximum and minimum output value Roux Signal characteristics of the analog output signal ouX switching characteristics for switching output x tun temperature unit roux assignment of switching output x to level or temperature monitoring d 5 refresh rate of the display Loc key lock Suou recorded switching output denn delay for recording minimum maximum temperature Note In case customized default values are set these values may differ from the standard factory settings as given in the following tables Design with 2 switching outputs Switching Outputs Basic Settings Diagnostics SPIIcPI 50 45 tun t out d5 i dr lou 0 0 Hno rou LETIP HH SP2 rPe 60 55 roue LETIP d5e dre ou U lllHna d 5 FASE Loc 000 BX100022 02 2010 Art Nr 90
7. 7 3 Technische Daten 7 3 Technical Data NT MD Basiseinheit Basic unit max Betriebsdruck 1 bar 14 5 psi max operating press Betriebstemperatur 20 C 80 C 4 F 176 F operating temperature Dichte Fluid 0 80 kg dm 0 029 Ib in Density fluid Ausf hrung MS Type MS Schwimmer PU float Tauchrohr Messing brass immersion tube Flansch G3 4 Messing brass flange G3 4 Niveaumessung Level measurement Kontakte NO NC max Anzahl K8 2 contacts NO NC max number Temperaturmessung Temperature measurement Temperatursensor Pt100 temperature sensor Temperaturausgange 2x PNP temperature outputs 1x PNP 1x 4 20 mA 4 x PNP Display Display Temperaturanzeigebereich 20 C 120 C 4 F 248 F temperature range Einstellbereich Alarm 0 C 100 C 32 F 212 F alarm range Genauigkeit 1 accuracy Aufl sung 0 5 C 1 F resolution Schutzart IP65 protection class Einschaltstromaufnahme 100 mA 100 ms current consumption at power up Stromaufnahme im Betrieb 50 mA operating current consumption Versorgungsspannung 10V 30 V supply voltage Nennspannung 24 V nominal voltage Umgebungstemperatur 20 C 70 C 4 F 158 F ambient temperature Technische Daten der Kontakte siehe 7 4 for technical data of contacts see chapter 7 4 7 4 Technische Daten Kontakte 7 4
8. Check An1 An gt Parameters Test of Analog 1 nof Lo A Y gt Exit E Exit submenu b d gt Exit E Exit submenu ww 51 Basic EF bEF Reset PES Confirm Bas Basis Erw Funktionen Restore factory settings nn YES Set Unit Temp tuin Parameters a Unit of temperature f E F A V Display Rate lt 5 Parameters ___ Display refresh rate f FASE aFF A V Lock Device Loc Parameters __ Locking the keypad f o 999 AV AV Exit E Exit submenu Diagnostic 2 A Journal Out out Parameters Diagnosp Men List of alarms dar T A Y Max Min Temp i Parameters 4 gt z Max Min memory temp 2al 2 Y A Y Set Jornal Out Suiou Parameters jout Recorded output f Gut i Dot AV AV Delay MM den Parameters __ Delaty time for Min Max D ig A V Exit E Exit submenu w Exit E Exit menu Resetting the device to factory settings Selecting the displayed temperature unit E Celsius F Fahrenheit Setting the display refresh rate FASE schnell Ed medium 5Lo langsam oFF Anzeige aus Activating the key lock by setting a code gt 7 Master code Z8 1 Display of the last 6 alarms and reset Display Jar X elapsed time in hours days scroll the jo
9. IEEE Grad Celsius Grad Fahrenheit Hinweis Bei Anderung der Einstellung werden alle zugeh rigen Einstellungen wie z B Einstellung der Schaltpunkte entsprechend ge ndert 4 6 2 Aktualisierungsrate der Anzeige einstellen Je nach Anwendung kann die Aktualisierungsrate der Anzeige eingestellt werden Die Anzeige kann auch ganz ausgeschaltet werden Die Funktion der LEDs ist weiterhin gegeben Basic EF AEF Display Rate 4 5 P gt Wahlmen Basis Erw Funktionen Anzeigegeschwindigkeit FASE aFF d Folgende Auswahlm glichkeiten stehen zur Verf gung S nee DOG TL TE FASE ME di Slo off schnell medium langsam Anzeige aus Hinweis Fehlermeldungen werden trotz ausgeschaltetem Display angezeigt 12 BX100022 02 2010 Art Nr 90 32 035 Bedienungs und Installationsanleitung Installation and Operation Instruction Ww Nivotemp NT MD PU HMERS TECHNOLOGIES 4 6 3 Tastensperre aktivieren deaktivieren Um unbefugte nderungen der Einstellungen im Ger t zu verhindern kann eine Tastensperre eingerichtet werden Basic EF bEF gt Lock Device Loc gt Wahlmen ar Basis Erw Funktionen Sperren der Taster B 999 Die Tastensperre wird aktiviert wenn mindestens eine Ziffer gt 0 eingegeben wird Wahrend der Eingabe wird die aktive Ziffer mit einem
10. Set A OUtX Alou_ y Wahlmen Hauptmen Messgr e Einstellmen Analog X Funktion des Ausgangs 2147009 ul A Folgende Wahlm glichkeiten stehen zur Verf gung Oui pad u i 658 u 3 4 mA bis 20 mA 2 V bis 10 V 0 V bis 10 V 0 V bis 5V 20 BX100022 02 2010 Art Nr 90 32 035 Bedienungs und Installationsanleitung Ww Installation and Operation Instruction oo Nivotemp NT MD Ax STILI TECHNOLOGIES 4 8 4 Analogausgang x Testen des Analogausgangs Auch der Analogausgang kann getestet werden Der gr te der mittlere und der kleinste Analogwert k nnen nacheinander ausgegeben werden Die Einstellung erfolgt im Men Messgr e ____ gt Hauptmen Messgr e Analog OutX An_ Check AnX LH5 Wahlmen Einstellmen Analog X Funktionstest Analog X naP FULL gt T fn Folgende Wahlm glichkeiten stehen zur Verf gung Hn i n o P Hi Normalbetrieb Ausgabe h chster Analogwert HRLF Lo Ausgabe mittlerer Analogwert Ausgabe niedrigster Analogwert Hinweis Stellen Sie die Funktion nach Beendigung des Tests unbedingt auf Normalbetrieb no ein 4 9 Diagnosemoglichkeiten Das Ger t ist in der Lage die Ereignisse f r einen Schaltausgang zu protokollieren Als Ereignis wird dabei das Aufleuchten der LED bezeich
11. insbesondere metallische Partikel enthalten sein um Ablagerungen am Schwimmer oder zwischen Schwimmer und Schaltrohr zu vermeiden Falls notwendig muss das Medium gefiltert werden Alle Ger tetypen sind ausschlie lich f r industrielle Anwendungen vorgesehen Es handelt sich nicht um Sicherheitsbauteile Die Ger te d rfen nicht eingesetzt werden wenn bei ihrem Ausfall oder bei Fehlfunktion die Sicherheit und Gesundheit von Personen beeintr chtigt wird Der Einsatz in explosionsgef hrdeten Bereichen ist nicht gestattet 4 BX100022 02 2010 Art Nr 90 32 035 Bedienungs und Installationsanleitung Installation and Operation Instruction b af Nivotemp NT MD EURER TECHNOLOGIES 1 2 Funktionsweise 1 2 1 F llstands berwachung Das Messrohr befindet sich im Tank Die Niveaukontakte sind innerhalb des Messrohrs angeordnet Sie werden durch einen Magneten im Schwimmer des Niveauschalters bet tigt Die Kontakte sind im vorgegebenen Abstand in einer Kantenschiene gem Bestellung geklemmt 1 2 2 Temperatur berwachung Es stehen bis zu vier Schaltausg nge oder ein Schaltausgang in Kombination mit einem programmierbaren Analogausgang zur Verf gung Die Schaltcharakteristik der Ausg nge kann als ffner Schlie er mit Fenster oder Hysteresefunktion oder als Frequenzausgang programmiert werden Die Programmierung erfolgt ber ein Men das an das VDMA Einheitsblatt 24574 ff angelehnt ist Ein dauerhafter Min Max
12. steigend SchlieRer Die LED leuchtet wenn der Maximalwert der Temperatur berschritten wird und die Temperatur au erhalb des gew nschten Bereiches ist Der Angezeigte Status ist also Fehler bei Leuchten der LED e Unterer Schaltkontakt Min Kontakt steigend SchlieRer Die LED leuchtet also bei der Werkseinstellung wenn der Minimalwert der Temperatur berschritten wird Es w rde in diesem Fall die LED leuchten wenn der Status in Ordnung ist Die Tabelle zeigt ein Beispiel mit der Werkseinstellung und mit invertierter Statusfunktion f r LED3 Die Schaltpunkte sind wie folgt definiert 18 BX100022 02 2010 Art Nr 90 32 035 Bedienungs und Installationsanleitung Installation and Operation Instruction Nivotemp NT MD vw TER TECHNOLOGIES SP3 70 C rP3 65 C SP4 80 C rP4 75 C Werkseinstellung Statusfunktion LED3 Zustand Status invertiert A l m E CO Temperatur steigt auf gt 70 C OK i let 1 el PNP Schaltausgang 3 geschlossen LED3 AN LED3 AUS B mm See wm Temperatur steigt auf gt 80 C Fehler B It B It PNP Schaltausgang 4 geschlossen LED4 und LED3 AN nur LED4 AN C mm ae CO Temperatur fallt auf 75 C OK 1 ut i 140 PNP Schaltausgang 4 ge ffnet LED3 AN LED3 AUS D LE m mi m Temperatur fallt auf 65 C Fehler 5 ut b ut PNP Schaltausgang 3 ge ffnet LED3 AUS LED3 AN Hier k nnen Sie f r einen Kontakt di
13. 32 035 33 Bedienungs und Installationsanleitung Installation and Operation Instruction fis ef Nivotemp NT MD 4207 ay TECHNOLOGIES Design with 4 switching outputs Switching Outputs Basic Settings Diagnostics SP tirP i 50 45 tum t out d5l dr llou D B Hno roul LETIP og SP2 P2 60 55 roue EETIP d5e dre aud D B Hno rou3 LETIP SP3 rP3 10185 rau EETIP d53 dr3lou3 0 0 Hno dS FASE SPY IrP4 80115 Loc 000 d5 dr 4 aud 0 0 Hno Design with 1 switching output and 1 analog output Switching Output Basic Settings Diagnostics SPIIcPI 50 45 Eun t Sdou out dS t drtlaul 0 0 Hno roul EENP desi HH Analog Output di5 FRSE A iHi IR ILo I Rou G 1001 Loc HHH 4 7 Switching Outputs All switching outputs are set in a similar way Therefore the number of the switching output is marked X Select the desired switching output by opening the respective main menu AV y Meas value ____ gt Out X nut Main menu meas value Settings OUTX Sub menu Extended functions EFX provides further settings for each switching output affecting for example the switching characteristics of the output The switching output can be tested as well in this sub menu 34 BX100022 02 2010 Art Nr 90 32 035 Bedienungs und Installationsanleitung Installation and Operation Instruction b af Nivotemp NT MD EURER TECHNOLOGIES
14. 4 7 1 Switching Output 1 Definition of the Switching Characteristics The switching characteristic is set in the following menu Meas value ____ gt gOut X outs gt gEF X EF Set Out X ou gt Parameter NE Main menu meas value Settings OUTX Extenden functions Definition OUTX Hna Fil The following options are available OU Hysteresis The switch works as NO or NC t contact If the set point is exceeded the output signal is set If the Hysteresis 5P P measuring signal falls below the H no reset point the output signal is reset Hysteresis NO contact is to be understood in the NO contact following way the PNP switching Time t output is closed if the measured value no contact i is above switching point 5Px and en pom u H nc opens if it falls below reset point r Px 1 i I Timet Hnc i Hysteresis NC contact is to be understood in the E E following way the PNP switching Qr PE i NC contact 4 a output is open if the measured value is mos met above switching point 5Px and closes if it falls below reset point r Px see as well figure below Window The switch works as NO or NC t contact The limits of the window are set by FH and FL If the measuring signal reaches the window the F no output signal is set If the measuring 7 E Win
15. An_ gt check AnX LHn Parameter En Main menu meas value Settings Analog X Test for Analog X naP FULL r A The following options are available Ani n o P Hi normal operation output of max analog value HRLF Lo output of middle analog value output of min analog value e g 12 mA with 4 20 mA setting Note After finishing the tests make sure to reset the function to normal operation nof 4 9 Diagnostic Tools The device is able to journalize the events of a selected switching output An event is defined as an LED lighting up Therefore the recording of events depends on the settings for the switching function of the LED see chapter 4 7 7 Settings and analysis are available in menu Diagnostic d A Menu diagnostics Only one switching output can be journalized The respective switching output is selected in menu item switching output journalize alarm log SLR gt Press W to open the main menu gt Select menu item d A using W and A This menu provides several diagnostic tools and journals of level and d N H temperature measurement gt Open the menu using P Now you can set diagnostic parameters or recall the journal BX100022 02 2010 Art Nr 90 32 035 41 Bedienungs und Installationsanleitung ww Installation and Operation Instruction cxi Niv
16. Anschlussbelegung sse enne ennen ener ener nennen nennen nns 45 7 3 Technische Daten irre re eta dee kde ee dede renault 46 7 4 Technische Daten Kontakte sssssssssssseseeeenenen nennen nennen nennen nenne nnne 46 7 5 Abmessungen aan eei a edd e LEO a ed Y n e a e d Y e n a n e 47 7 6 Aktuelle Einstellungen ssssesseeneeenenen mene en nennen nennen neri nennen nnn nennen 48 7 7 bersicht Men ablalge s n meter iride aderat eid adinim aar naa ud 49 2 BX100022 02 2010 Art Nr 90 32 035 Bedienungs und Installationsanleitung Installation and Operation Instruction Nivotemp NT MD vw Zu XTTUTLISIET TECHNOLOGIES Contents Page 1 rep TT S a rn eb ne ne en 25 1 1 Range or Iq 25 1 2 FunctionallDescriptlOni 5 1c ert iet n Pete eld a eaaa aien aaia eana ennaa an aaia 26 1 2 1 EarkesnubBe M 26 1 2 2 Temperature Control rr ttt din YR RA ATO RE ni XC ERR 26 2 important ADVICE SERTFPRRAPUCFPRRFEHTFFERAPULFENESEBTFFERRFULEPRRSEHTEFERRELTUEFRENRFEFFPEFLLEEFEGENTERERELHTETSEGLSTTTTRERNTLT 26 SA bee 28 SE coolmt PN 29 4 1 SWITCHING OM e 29 4 2 LED Status Display ccceeecceee sence ee ceeeeeeeeeneeeeeeaeeeeeceaeeeeeseaeeeeeseeaeeeseeeeeeeseneaeeeseneaeeeseeaeeeeeeatees 29 4 3 Common Key F nctlons eed etate anheben 30 4 4 Key LOCK active RR 3
17. Messwertanzeige A Im Men Wechsel zur n chst h heren Men ebene 60 s keine Aktion Im Men Verlassen des Haupt Unter Wahlmen s Das Verlassen des Wahl bzw Einstellmen s erfolgt ohne Speicherung der ge nderten Werte Zur Auswahl eines Men punktes und zur Einstellung der Werte gehen Sie wie folgt vor gt ffnen Sie das Hauptmen mit der Taste gt gt Wahlen Sie das Untermen mit den Tasten V und A aus und ffnen Sie das Untermen mit der Taste gt gt W hlen Sie ggf das n chste Untermen mit den Tasten W und A und ffnen Sie es mit der Taste gt Wahlen Sie den gew nschten Men punkt mit den Tasten V und A aus und ffnen Sie die Werteliste mit der Taste gt gt Stellen Sie den Wert mit den Tasten V und A ein und best tigen Sie mit der Taste Die ge nderten Einstellungen werden gespeichert und das Ger t kehrt zum Untermen zur ck gt Verlassen Sie das Untermen in dem Sie den Men punkt EXIT anw hlen und mit der Taste gt best tigen Das Ger t kehrt zum bergeordneten Men bzw zur Messwertanzeige zur ck BX100022 02 2010 Art Nr 90 32 035 9 Bedienungs und Installationsanleitung Installation and Operation Instruction fi il Nivotemp NT MD BUMMER TECHNOLOGIES 4 4 Aktive Tastensperre Wenn die Tastensperre aktiviert ist erscheint beim Aufrufen des Men s mit der Taste W die Anzeige 000 an Stelle des Hauptmen s Die aktive Ziffer wird durch e
18. OUT1 Obere Schaltgrenze 1 UL iar rPl Fit Filo gt Wahlmen _ _ Untere Schaltgrenze 1 f UL IDOL A V EF 1 EF Delay SP 1 45 Wahlmen Erweiterte Funktionen Verz gerung OUT1 Ein D 100 Delay RP 1 Zr Wahlmen Verz gerung OUT1 Aus ag iad AV Set Out1 ou Wahlmen Definition OUT1 f Hno FA AV AV Check Out Lou Wahlmen _ AV Test OUT1 nof on gt AV LED Out1 4 Wahlmen Funktion Status LED1 bz g gt bse AV Exit E Verlasse Men ebene gt gt Exit E AV Verlasse Men ebene Ww Out x nut k gt gt Siehe Men struktur Out1 Einstellmen OUTx Entf llt bei Variante mit Analogausgang Analog Out1 An gt Analog Max1 A iH gt Wahlmen _ Einstellmen Analog 1 Zuweisung Max Wert UL iat Analog Min1 i a Wahlmen Zuweisung Min Wert UL iat A V Set A OUt1 Rou i Wahlmen Funktion Ausgang 1703 AV AV gt Check An1 An gt Wahlmen _ Test Analog 1 nof Lo A V Exit E Verlasse Men ebene l ae gt Exit E Verlasse Men ebene w Entf llt bei Bestellung mit 2 oder mehr Schaltausg ngen i ER Best ti nes TRE Basic EF BE Reset pes 4 r estauigund R cksetzen des Ger tes in Auslieferungszustand Basis Erw Funktionen Werkseinstellung no YES Set Unit Temp L un gt Wahlmen _ Auswahl der angezeigten Temperatureinheit Einheit Tempera
19. Punkt markiert L Oo C gt ffnen Sie die Werteliste mit der Taste P GU Einstellbereich gt Stellen Sie die Ziffer mit den Tasten W und A ein 0 bis 9 und bestatigen 000 bis 999 f Sie mit der Taste Die aktive Ziffer r ckt um eine Stelle nach rechts gt Best tigen Sie den Code zum Schluss mit der Taste gt Das Gerat kehrt zum Untermen zur ck Hinweis Tastatursperre aufheben mit der Eingabe 000 4 6 4 Werkseinstellungen wieder herstellen Reset Mit der Funktion Reset E5 k nnen die Werkseinstellungen wieder hergestellt werden Dabei gehen alle Anderungen verloren Da die Grenzwerte ebenfalls zur ckgesetzt werden m ssen die Einstellungen f r den F llstand und die Temperatur unbedingt berpr ft werden Basic EF bEF Reset rES gt Best tigung ___ Basis Erw Funktionen Werkseinstellung i nn YES 6 Folgende Wahlm glichkeiten stehen zur Verf gung no BES Auslieferungszustand Nein Auslieferungszustand Ja die aktuellen Einstellungen die Einstellungen werden auf die werkseitigen werden beibehalten Standard Einstellungen zur ckgesetzt Die Werkseinstellungen lauten folgenderma en Definitionen SP IrPx Schaltpunkt R ckschaltpunkt x d5x drx Einschaltverz gerung R ckschaltverz gerung f r Schaltausgang x RX H AX Lo NA AA Er und minimaler Messwert f r die Ausgabe
20. Roux Signalform des Analogausgangs ouX Schaltcharakteristik des Schaltausgangs x tun Einheit fur Temperatur roux Zuordnung des Schaltausgangs x zur Temperatur berwachung d 5 Aktualisierungsrate des Displays Loc Tastensperre Sdou protokollierter Schaltausgang dtfifi Verz gerung zur Aufzeichnung der minimalen maximalen Temperatur Hinweis Bei kundenspezifischen Vorgaben kann die werkseitige Voreinstellung von den hier aufgef hrten Werten abweichen BX100022 02 2010 Art Nr 90 32 035 13 Bedienungs und Installationsanleitung Installation and Operation Instruction Nivotemp NT MD vw mr UI La TECHNOLOGIES Ausf hrung mit 2 Schaltausg ngen Schaltausg nge Basiseinstellungen Diagnose SP ilrPi 50 45 Eum t out I dS t dr llou Ul lHna rou EETIP oo SP2 rPe 601 55 rouc EEfIP d58 dre oud D D Hno dS FASE Ausf hrung mit 4 Schaltausg ngen Schaltausgange loc 000 Basiseinstellungen SPiirP i 50 45 Euni t d5lldr llou D D Hno roul EETIP Se rP2 60 55 roul LEMP d52e dre oug Ul lHno rou EETIP 5P3 rP3 10165 rout EETIP d53 dr3 ou3 D D Hno dS FASE SPY PY 891 15 Loc HHH d5 dc 4 au4 Ausf hrung mit 1 Schaltausgang und 1 Analogausgang D D Hno Schaltausgang Basiseinstellungen Diagnos
21. Speicher f r die Temperatur sowie ein Logbuch stehen zur Verf gung Im Logbuch werden die letzten 6 Ereignisse des zu protokollierenden Schaltausgangs gespeichert und k nnen abgerufen werden 2 Wichtige Hinweise Bitte berpr fen Sie vor Einbau des Ger tes ob die genannten technischen Daten den Anwendungs parametern entsprechen berpr fen Sie ebenfalls ob alle zum Lieferumfang geh renden Teile vollst ndig vorhanden sind Der Einsatz der Ger te ist nur zul ssig wenn das Produkt unter den in der Bedienungs und Installationsanleitung beschriebenen Bedingungen dem Einsatz gem Typenschild und f r Anwendungen f r die es vorgesehen ist verwendet wird Bei eigenm chtigen nderungen des Ger tes ist die Haftung durch die B hler Technologies GmbH ausgeschlossen die im Datenblatt und der Anleitung angegebenen Grenzwerte eingehalten werden Uberwachungsvorrichtungen Schutzvorrichtung korrekt angeschlossen sind die Service und Reparaturarbeiten die nicht in dieser Anleitung beschrieben sind von B hler Technologies GmbH durchgef hrt werden Originalersatzteile verwendet werden Diese Bedienungsanleitung ist Teil des Betriebsmittels Der Hersteller behalt sich das Recht vor die Leistungs die Spezifikations oder die Auslegungsdaten ohne VorankUndigung zu andern Bewahren Sie die Anleitung fur den spateren Gebrauch auf In dieser Anleitung werden folgende Warnzeichen und Signalw rter benutzt Wa
22. is displayed by pressing A in normal operation mode A 4 digit code is shown for example 7 4 1 The four digits tsav have the following meaning t on VI E ui t Type t temperature measurement o level and temperature measurement to e SEN S No of switching outputs 1 20r4 a No of analog outputs 0 or 1 Mounting installation i standard mounting tank top installation F remote display Configuration E__ The menu item is only displayed if the option is equipped Device configuration Example if a 0 than menu items for setting analog outputs are not available You may skip these OE e descriptions IE ut The structure of the menus for the switching outputs and Main menu temperature P Setings for OUT analog outputs is similar These menus include all y settings for the switching outputs and the analog outputs Oo out A un for OUTx If equipped if equipped AY Analog Out1 An General settings can be changed as well They are set in x 2n Setings forAnaogi_ equipped main menu Basic settings extended functions bEF r y These settings should be changed first because they ext sona affect displays and settings of the sub menus General l settings are for example used units and assignment of Basic EF _ bEF the switching outputs to level or temperature control The Basic ext funct
23. tube is installed into the tank The level switches are adjusted inside the measuring tube They are operated by a magnet inside of the float The device is equipped with contacts fixed on a bar at specified distance 1 2 2 Temperature Control The NT MD is equipped with up to four switching outputs or one switching output combined with a programmable analog output for temperature control The switching characteristic of the output is programmable as NO NC contact with window or hysteresis output characteristic or as frequency output A menu based on VDMA standard 24574 provides easy programming Minimum and maximum temperature can be stored permanently A logbook stores the last 6 events of the monitored switching output The logbook can be looked up 2 Important advice Please check prior to installation of the device that the technical data matches the application parameters Check that the delivery is complete as well Operation of the device is only valid if the product is used under the conditions described in the installation and operation instruction the intended application according to the type plate and the intended use In case of unauthorized modifications done by the user B hler Technologies GmbH can not be held responsible for any damage the performance limits given in the datasheets and in the installation and operation instruction are obeyed monitoring devices and safety devices are installed properly s
24. y Analog OutX An y Analog MinX A iLo Settings Analog X Minimum value H IL Oo Note The set output range must not be smaller than 1096 of the measuring ae Bde range A tH R ILo gt 1096 32 E 212 F Ifthe output range is set to small the analog output signal may show steps 4 8 3 Analog Output x Setting the Output Characteristic The output characteristic of the analog output may be defined as voltage output or as current output with different signal output ranges The output characteristic is set in the following menu Meas value gt Analog OutX gt Set A OUX Hau gt Main menu meas value Settings Analog X Output characteristics Parameter pz un ul u The following options are available Hou i u i u C u 3J 4 mA to 20 mA 2Vto 10V 0 Vto 10V OVto5V 40 BX100022 02 2010 Art Nr 90 32 035 Bedienungs und Installationsanleitung v Installation and Operation Instruction Nivotemp NT MD TLT TECHNOLOGIES 4 8 4 Analog Output x Testing the Analog Output The analog output can be tested as well The highest the mean and the lowest analog value can be put out one after the other The parameters are set in the following menu Meas value ____ gt p Analog OutX
25. 1 4 5 Overview Menu Str ctUre coiere rete eet dee tee e enar ande eee ane ea ES 31 4 6 Changing general Settings sssssssssessses eee nennen nennen eere n nennen nennen nnns 32 4 6 1 Setting Unit for Temperature Measurement sssssssssesssseeee nennen nnns 32 4 6 2 Setting the Display Refresh Rate ssssssssssessssseeeeeeeenen nennen nennen nnne 32 4 6 3 Activating deactivating Key LOock ssssssesseeeeneeen menn nere en neret 32 4 6 4 Reset Factory Settings sse ener enne nennen rennen nnns 33 4 7 switching ove 34 4 7 1 Switching Output 1 Definition of the Switching Characteristics esseee 35 4 7 2 Switching Output x Upper Limit Set Point nennen 36 4 7 3 Switching output x Lower Limit Reset Point enne nenne 36 4 7 4 Switching Output x Delay for Set Point sssssssssssssssene enne 37 4 7 5 Switching Output x Delay for Reset Point sssssssssseene nennen 37 4 7 6 Switching Output x Testing the switching output ssssseeee eene 38 4 7 7 Switching Output x Changing Switching Function of LED sse enm 38 4 8 Analog OUMU enerci c m 40 4 8 1 Analog Output x Setting the upper Limit esssssssssseseeneeemeenn n 40 4 8 2 Analog Output x Setting the lower Limit sssseeenm emm e
26. 2 02 2010 Art Nr 90 32 035 Bedienungs und Installationsanleitung Installation and Operation Instruction Nivotemp NT MD vw TER TECHNOLOGIES Konfiguration _ Ger tekonfiguration ES A ies AV ww Temperature t nP gt Out 1 out I Hauptmen Temperatur Einstellmen OUT1 n AV Outx out Einstellmen OUTx Falls vorhanden AV Analog Out1 Ana gt AY Einstellmen Analog 1 Falls vorhanden gt AV Exit E Verlasse Men ebene 7 v Basic EF 5 Basis Erw Funktionen Diagnostic d A Diagnose Men Exit E Verlasse Men ebene Die einzelnen Men punkte erscheinen nicht wenn die Option nicht vorhanden ist Beispiel Bei a 0 sind die Men punkte zur Einstellung des Analogausgangs nicht vorhanden Sie k nnen die Beschreibung dieser Punkte dann berspringen Die Struktur der Men s f r die Schalt und Analogausg nge ist gleichartig Hier werden die Einstellungen f r die Schaltausg nge bzw die Analogausgange falls vorhanden vorgenommen Die Grundeinstellungen des Ger tes k nnen ge ndert werden Allgemeing ltige Einstellungen erfolgen im Men Basiseinstellungen Erweiterte Funktionen bEF Diese Einstellungen sollten zuerst vorgenommen werden da sie sich auf die Anzeigen und Einstellm glichkeiten in den einzelnen Men s auswirken Solche Einstellungen sind z B di
27. 22 02 2010 Art Nr 90 32 035 Bedienungs und Installationsanleitung Installation and Operation Instruction Nivotemp NT MD vw TER TECHNOLOGIES SP3 70 C rP3 65 C SP4 80 C rP4 75 C Factory settings Inverted function Situation Status of LED3 A mm E CO Temperature rises above 70 C OK l Tel 1 et PNP switching output 3 is closed LED3 ON LED3 OFF B mm Sue num Temperature rises above 80 C Error 8 It B It PNP switching output 4 is closed LED4 and LED3 ON only LED4 ON C mS m Emo m Temperature falls below 75 C OK 1 ut i 140 PNP switching output 4 is closed LED3 ON LED3 OFF D rz m CX m m m Temperature falls below 65 C Error 6 ut b qt PNP switching output 3 is opened LED3 OFF LED3 ON You can invert the function of the LED for the respective switching output The LED lights up if the contact is opened or in other words if the temperature falls below the minimum temperature and the active LED indicates an error Especially the recording of events depends on the status of the LED see chapter Diagnostic Tools 4 9 1 Meas value ____ gt gOut X nut REF X EF LEDOutX j 4 I ee gt Parameter Main menu meas value Settings OUTX Extenden functions Ww Behavior LEDX Ls tse The following options are available LEd b 250
28. Anzeige aise mit der Taste l scht die Ereignisliste und kehrt zum Untermen zur ck Hinweis Die gespeicherten Daten werden nach 6 Monaten berschrieben 22 BX100022 02 2010 Art Nr 90 32 035 Bedienungs und Installationsanleitung Installation and Operation Instruction B A Nivotemp NT MD EURER TECHNOLOGIES 4 9 3 Zu protokollierenden Schaltausgang festlegen Hier wird der zu protokollierende Schaltausgang ausgew hlt Es kann nur ein Schaltausgang protokolliert werden Diagnostic J A gt Set Jornal Out 5 i 5 gt y Wahlmen nut Diagnose Men berwachung Ausgang Buk t Dot o Jo LJ Hinweis Das Sichern der Werte vom fl chtigen in den nicht fl chtigen Speicher Auswahl erfolgt ca alle drei Stunden aut bis out X Die gespeicherten Daten werden nach 6 Monaten berschrieben 4 9 4 Verz gerung zur Min Max Speicherung der Temperatur Um bei Temperaturschwankungen zuverlassige Werte aufzuzeichnen kann eine Verz gerungszeit zur Speicherung der minimalen und der maximalen Temperatur eingestellt werden Hier wird die Zeitspanne in Sekunden angegeben in der das Signal kontinuierlich anliegen muss ehe die Temperatur protokolliert wird Diagnostic lt A gt Delay MM atsifi N Diagnose Men Verz gerung Min Max Wahlmen n in E
29. L 0 entspricht der Frequenz 1 Hz angezeigt Der eingestellte Wert 16 BX100022 02 2010 Art Nr 90 32 035 Bedienungs und Installationsanleitung ww Installation and Operation Instruction cxi Nivotemp NT MD Zu SU FILER TECHNOLOGIES 4 7 4 Schaltausgang x Einschaltverz gerung Im Men Erweiterte Funktionen EFx k nnen weitere Einstellungen f r den Schaltausgang x vorgenommen werden Das Untermen finden Sie auf der zweiten Untermen ebene Die Schalt und R ckschaltverz gerungszeit verhindert das zu h ufige Ansprechen des Alarms bei unruhigen Verh ltnissen Die Schaltverz gerung wird in folgendem Ment eingestellt Messgr e ____ gt Out X ouk_ gt gEF X ER y Delay SPX d5_ P Wahlmen me Hauptmen Messgr e Einstellmen OUTX Erweiterte Funktionen Verz gerung OUTX Ein DB ia Zeitspanne in Sekunden in der das Signal kontinuierlich anliegen muss damit d 6 l der Schaltausgang anspricht Hinweis A a Falls dem Schaltausgang OUT x die Funktion Fenster zugewiesen wurde entspricht der eingestellte Wert der Einschaltverz gerung die ein g ltiges Erreichen des Messfensters detektiert Falls dem Schaltausgang OUT x die Funktion Frequenzausgang zugewiesen wurde hat dieser Wert keine Auswirkung 4 7 5 Schaltausgang x R ckschaltverz gerung Die R ckschaltverz ger
30. LED output the LED lights up if the PNP Switching output is closed LED output the LED lights up if the PNP Switching output is opened Note Diagnostics 4 9 1 Recording of events depends on an activated LED lighting up see chapter BX100022 02 2010 Art Nr 90 32 035 39 Bedienungs und Installationsanleitung Installation and Operation Instruction A if Nivotemp NT MD 4207 ay TECHNOLOGIES 4 8 Analog Outputs 4 8 1 Analog Output x Setting the upper Limit Here the upper limit of the measured temperature is assigned to the maximum analog output signal The parameter is set in the following menu Meas value ____ gt Analog OutX Ain_ gt Analog MaxX H iH gt Parameter Main menu meas value Settings Analog X Maximum Value i talo ah 3 H LH i Note Range The set output range must not be smaller as 10 of the measuring 0 en 100 RC range R IH A iLo gt 10 32 F to 212 F Ifthe output range is set to small the analog output signal may show steps 4 8 2 Analog Output x Setting the lower Limit Here the lower limit of the measured temperature is assigned to the minimum analog output signal The parameter is set in the following menu Meas value ____ gt Main menu meas value gt Parameter ____ 4 gt Zr y Calo ahi 3
31. Select the menu item using W and A and press to show the parameter list or parameter value VV ON V Change the value using W and A and press to accept the changing The changed parameter is stored and the device returns to the sub menu v Exit the sub menu by selecting menu item EXIT and press The device returns to the subordinate menu or to the measurement display respectively 30 BX100022 02 2010 Art Nr 90 32 035 Bedienungs und Installationsanleitung Installation and Operation Instruction b af Nivotemp NT MD EURER TECHNOLOGIES 4 4 Key Lock active If the key lock is activated pressing W displays UU instead of opening the main menu The active digit is indicated by a dot gt For each digit enter the correct number using A and W and press The active digit shifts to the right After entering the third digit the main menu opens If you entered a wrong password the device returns to normal mode If you have lost the password enter the master code 287 To unlock the key lock select menu item Loc in sub menu Basic Settings Extended Functions bEF and reset the password to 000 4 5 Overview Menu Structure The menu structure is based on VDMA standard 24574 The menu is structured hierarchically The first level shows the main menu with menu item like EENP bEF d A E The menu items depend on the configuration Your device may not provide all menu items described below The configuration
32. Technical Data of Contacts Niveaukontakt K8 Level contact Schaltfunktion NO NC switching function max Spannung 30 V max voltage max Schaltstrom 0 5A max switching current max Kontaktbelastung 10 VA max contact load min Kontaktabstand 40 mm 1 57 in min contact distance Temperatursensor Pt100 Temperature sensor Klasse B DIN EN 60 751 class Toleranz 0 8K tolerance 46 BX100022 02 2010 Art Nr 90 32 035 Bedienungs und Installationsanleitung Ww Installation and Operation Instruction EU Nivotemp NT MD LEXU TUR TECHNOLOGIES 7 5 Abmessungen 7 5 Dimensions Alle Abmessungen in mm NT MD All dimensions given in mm Geh use um min 270 drehbar M12x1 Housing able to rotate 270 1 i i IHs S i ONT gt BEES Koes sw 36 24 _ A F 36 53 lt L lj Eolastic Dichtung T Ql NBR gasket c I E G3 4 o x j e 4 i 9S t ET ols d NO e EI E N I 1 l o 223 5 ue S E i i Adapter f r Ovalflansch Option Adapter for oval flange option BX100022 02 2010 Art Nr 90 32 035 47 Bedienungs und Installationsanleitung Installation and Operation Instruction fi tl Nivotemp NT MD 427 ay TECHNOLOGIES 7 6 Aktuelle Einstellungen 7 6 Actual settings Ausf hrung mit 4 S
33. alten Das Ger t darf nur von instruiertem fachkundigem Personal installiert gewartet und in Betrieb genommen werden GEFAHR Giftige tzende Gase Fl ssigkeiten Sch tzen Sie sich bei allen Arbeiten vor giftigen tzenden Gasen Fl ssigkeiten Tragen Sie die entsprechende Schutzausr stung Die Niveauschalter werden komplett montiert geliefert und k nnen mit dem Einschraubgewinde direkt am Beh lter befestigt werden Der Schwimmer muss sich frei bewegen und gen gend Abstand zur Beh lterwand und anderen Einbauten einhalten Nach einer Demontage des Schwimmers muss der Magnet im Schwimmer beim erneuten Einbau oberhalb des Fl ssigkeitsspiegels liegen Kontrollieren Sie die Lage des Magneten mit einem Eisenst ck Die Kontaktlogik geht davon aus dass der Niveauschalter bei leerem Tank installiert wird d h er ist erst nach dem Bef llen in der Betriebsposition Die Niveaukontakte sind gem Bestellung als Schlie er oder Offner ausgef hrt und in der angegebenen Lage montiert Lage und Funktion der Kontakte k nnen nicht ge ndert werden Technische Hinweise Lebensdauerverl ngerung von Reedkontakten F llstand Reedkontakte sind konstruktionsbedingt sehr langlebige und zuverl ssige Bauteile Trotzdem sollten Sie folgendes beachten Kontaktabsicherung BEL ais Zu hohe Induktivlasten die beim ffnen eines Reed Schalters eine Last hohe R ckspannung erzeugen k nnen mittels folgender Schaltung m verringer
34. ample e Maximum temperature lel press V e Reached x hours days ago 84h press V A e Minimum temperature ecl press V A e Reached x hours days ago eth press V A e Delete press A P delete t f fi Accepting BEEE with gt deletes the journal and returns to the sub menu Note alae The stored data is overwritten after six months time min value time delete reset 42 BX100022 02 2010 Art Nr 90 32 035 Bedienungs und Installationsanleitung ww Installation and Operation Instruction cxi Nivotemp NT MD Zu SU FILER TECHNOLOGIES 4 9 3 Assigning the Switching Output for recording In menu Suou the switching output to be recorded is assigned Only one switching output can be journalized Diagnostic d A gt Set Jornal Out 5iiou gt Parameter owt_ Diagnostics menu Set recorded output Dut i Dut A 5 U O U note Approx every three hours the values of the volatile memory are transferred to the non volatile memory Range out to ouEX The stored data is overwritten after six months 4 9 4 Delay for recording min max Temperature A delay time guarantees recording of reliable values for minimum and maximum levels in case of fluctuating temperature A time interval in seconds is set during which the signal must at least remain at maximum or minimu
35. ange Selecting the analog output signal zai 1 4 20mA wu 2 10V ug 0 10V u 320 5V noP normal operation Hi output maximum analog value HALF output middle analog value La output minimum analog value Alternative menu for models with analog output Not available for models with 2 or more switching outputs Main menu Submenu 1 Submenu 2 Submenu 3 Parameters Configuration Device configuration A v Pressing keys or no action for 60 s Exits the menu A V Temperature E gt Out 1 aut gt SPI HILF Parameters Main menu temperature Settings for OUT1 Upper limit 1 UL iat rPI FLI Flo Parameters ____ Lower limit 1 UL iat AV EF 1 EFI Delay SP 1 425 Parameters Extended functions Delay for set point D IUD p E Delay RP 1 c Parameters Delay for reset point D IUD SetOut1 su Parameters Definition OUT1 Hno Ff AV No Check Out fou Parameters Test of OUT1 naP an LED Out1 4 Parameters i __ Switching function LED1 Ls 5 5 Ls 6 Exit E gt Exit submenu Ww AV gt Exit Exit submenu w Out x nut gt See menu structure Out1 Settings for OUTx Not available for models with analog output Analog Out1 An gt Analog Max1 A iH Parameters ____ Settings for Analog 1 Setting max value UL IUD Analog Min1 Hia Parameters Setting min value UL IUD A Y Set A OUT1 Aou Parameters _ Setting characteristics A tou AV AV
36. ate can be set The display can be shut off as well In this case the function of the LED remains active Basic EF b F gt Display Rate c 5 gt Parameter Basic ext functions Display refresh rate FASE off di 5 The following options are available FASE ME di Slo off fast medium slow display off Note Error messages are displayed even if the display is shut off 4 6 3 Activating deactivating Key Lock To prevent unauthorized parameter changing activate the key lock Basic EF AEF Basic ext functions N Lock Device L oc gt Parameter Ser Lock key pad g 888 The key lock is active if at least one digit is set gt 0 When setting the password the active digit is indicated with a dot 32 BX100022 02 2010 Art Nr 90 32 035 Bedienungs und Installationsanleitung Installation and Operation Instruction ad Nivotemp NT MD xe vL IE TECHNOLOGIES L O C gt Open the parameter menu using gt 0 0 Range Enter first number of the password 0 to 9 using W and A and accept it by 000 to 999 pressing gt The active digit moves one step to the right gt Enter all digits and accept the password with P The device returns to the sub menu Note Enter 000 to deactivate the key lock 4 6 4 Reset Factory Settings
37. auf dem Typenschild und technische Daten NO Schlie er NC ffner Contact position in measured from top to bottom Contact 1 at position L1 Contact 2 at position L2 Contact 3 at position L3 and so forth Note Depending on the model the number of contacts is limited see product key on type plate and technical data NO normally open NC normally closed 7 2 Standard Pin Assignment belegung Andere Belegung auf Anfrage other assignment on request Steckverbinder 2 x M12 Sockel base Connector A Niveau A B A level B Temperatur d i B temperature i Niveaukontakt e A L1 level contact s Oc 1 m 4 2 Temperaturausg nge so oy 2 2 temperature outputs en 3 B 2 D 1 24V DC Oc 2 T2 PNP ESL D 3 GND 4 T1 PNP LZ Pt100 RTD Niveaukontakt e A 2 E id level contact s o L2 1 Temperaturausgang 3 o 1 1 temperature contact 1 Analogausgang 7 xc 1 analogue output B 2 D 1 24VDC Oc 2 T2 4 20 mA ae D 3 GND 4 T1 PNP LZ Pt100 RTD Niveaukontakt e 8 gt PN level contact s 4 Temperaturausg nge 4 es o 3 GND 4 temperature outputs ao 4 T1 PNP 5 7 5 T3 PNP 6 p 6 T4 PNP 4 pric RTD BX100022 02 2010 Art Nr 90 32 035 45 Bedienungs und Installationsanleitung Installation and Operation Instruction Nivotemp NT MD Ww mr UI aR TECHNOLOGIES
38. chaltausg ngen Design with 4 switching outputs Basiseinstellungen Basic settings Schaltausg nge switching outputs Diagnose Diagnostic Sdou dof desi d5 dc 4 aud Ausf hrung mit 2 Schaltausgangen und 2 Design with 2 switching outputs and 2 analogue Analogausgangen outputs Schaltausgange Switching outputs Basiseinstellungen Diagnose Diagnostic Basic settings Sdou dofifi den d5e dre ou Analogausgange Analog outputs A IHi IR ILo I Rou ACH AeLo Rou Datum Date Unterschrift Signature 48 BX100022 02 2010 Art Nr 90 32 035 7 7 bersicht Men abfolge Hauptmen Untermen 1 Untermen 2 Konfiguration ___ Ger tekonfiguration ENEN A Vv Tastenkombination Y gt oder 60s keine Aktion Verlassen des Haupt Untermen Untermen 3 Einstell und Anzeigemen VX000010 5P Einstellung des Einschaltpunktes fH Festlegung der oberen Fenstergrenze F i Zuweisung eines Wertes der Frequenz 100 Hz Nur Out1 und O
39. cture VX000010 5P Setting for switching point FH Setting of upper window limit F itt Defines value for frequency output 100 Hz Out1 and Out2 only rP Setting for reset point FL Setting of lower window limit F iLo Defines value for frequency output 1 Hz Out1 and Out2 only Time in seconds which the signal must at least remain to enable the switch to operate Setting range 0 100 seconds no function with frequency output Time in seconds which the signal must at least remain to enable the switch to reset Setting range 0 100 seconds no function with frequency output Defines the switching characteristics for output 1 Mna Hnc Hysteresis NC or NO Fna Fnc Window NC or NO n Frequency output 1 100 Hz naP normal operation of the switching output aFF Switching output OFF Fi output 1 Hz on Switching output ON F 188 output 100 Hz i o LED output same as switching output Lz a LED output inverted to switching output Setting the maximum output signal to a defined value Note Max Min gt 10 of the measuring range Setting the minimum output signal to a defined value Note Max Min gt 10 of the measuring r
40. dow with signal leaves the window the output i M S Tiret NO contact signal is reset we E ET NO contact is to be understood in the following way the PNP switching 0 1 t Oee o F output is closed if the measured value c contac nc is within the window limits Otherwise m Window with it is open La gt Timet NC contact NC contact is to be understood in the following way the PNP switching output is open ifthe measured value is within the window limits Otherwise it is closed Hee E aceon Rp oo CU with a frequency between zan n 100 Hz in proportion to the I r T lt Fillo FR n measuring signal is set at the output Een Aen o Timet Note In order to increase the slope Frequency output T 47 5 C is equivalent to f 50Hz Timet of the square wave we recommend av 24 V T gt fih is equivalent to TRA do Timet 10 kQ resistor loading the switching output with a BX100022 02 2010 Art Nr 90 32 035 35 Bedienungs und Installationsanleitung Installation and Operation Instruction fi af Nivotemp NT MD 42 ay TECHNOLOGIES Note The switching function may have different notations SP SP rP rP open c
41. e SP i irP i 50 45 tun t Sou out dS tidr llou 0 01 Hno roul LETIP den oo Analogausgang d 5 FRSE R IH IR tLo Rou 0 as I 4 7 Schaltausg nge Alle Schaltausg nge werden in gleicher Weise eingestellt Die Nummer des Schaltausgangs wird daher mit x dargestellt Rufen Sie den einzustellenden Schaltausgang ber das Men der entsprechenden Messgr e auf Loc HHH Messgr e ____ gt Out X nut Hauptmen Messgr e Einstellmen OUTX Im Untermen Erweiterte Funktionen k nnen weitere Einstellungen f r jeden einzelnen Schaltausgang vorgenommen werden die z B das Schaltverhalten des Ausgangs beeinflussen Auch ein Test des Ausgangs ist hier m glich 14 BX100022 02 2010 Art Nr 90 32 035 Bedienungs und Installationsanleitung Installation and Operation Instruction Nivotemp NT MD vw Zu SOE SE TECHNOLOGIES 4 7 1 Schaltausgang x Definition der Schaltcharakteristik Die Schaltcharakteristik f r den Ausgang wird in folgendem Men festgelegt Messgr e gt Hauptmen Messgr e Out X nut EF X EF Einstellnen OUTX Erweiterte Funktionen Set Out X ou_ gt y Wahlmen EM Definition OUTX Fit Hna OU Folgende Wahlm glichkeiten stehen zur Verf gung Hys
42. e verwendeten Einheiten und die Zuordnung der Schaltausg nge zu F llstands und Temperatur messung Die Zuordnung der Analogausg nge kann nicht ver ndert werden Zus tzlich stehen im Men Diagnostic M glichkeiten zur Diagnose zur Verf gung Die ausf hrliche Darstellung der gesamten Men struktur befindet sich am Ende dieser Anleitung BX100022 02 2010 Art Nr 90 32 035 11 Bedienungs und Installationsanleitung Installation and Operation Instruction fi af Nivotemp NT MD 42 ay TECHNOLOGIES 4 6 ndern der Basiseinstellungen Im Men Basiseinstellungen Erweiterte Funktionen bEF werden die allgemeing ltigen Basiseinstellungen vorgenommen Diese Einstellungen beeinflussen die Darstellung in der Messwertanzeige ebenso wie die Einstellm glichkeiten in den Men s F llstand und Temperatur Auch die Zuordnung der Schaltausg nge zur F llstands bzw Temperaturmessung soweit vorhanden kann hier ge ndert werden Dr cken Sie die Taste V um ins Hauptmen zu gelangen gt W hlen Sie den Men punkt bEF mit den Tasten V und A aus und ffnen Sie das Menu mit der Taste gt 4 6 1 Einheit Temperatur festlegen Hier wird das angezeigte Einheitensymbol f r die Temperatur festgelegt Basic EF BEF gt Set Unit Temp Eum gt Wahlmen Basis Erw Funktionen Einheit Temperatur EZF Folgende Wahlm glichkeiten stehen zur Verf gung tuni Eres
43. e Statusfunktion der LED umkehren Die LED leuchtet wenn der Kontakt ge ffnet ist also unterhalb der minimalen Temperatur und es wird bei Leuchten der LED wieder der Status Fehler angezeigt Insbesondere h ngt das Aufzeichnen von Ereignissen vom Aufleuchten der LED ab siehe Kapitel Diagnosem glichkeiten 4 9 1 Messgr e ____ gt N LED Out X L d_ Wahlmen j Out X out gt pEF X EF gt E Hauptmen Messgr e Einstellmen OUTX Erweiterte Funktionen Funktion Status LEDX Ls g L 0 Folgende Wahlm glichkeiten stehen zur Verf gung b 2508 LED output die LED leuchtet wenn der PNP Schaltausgang geschlossen ist LEd LED output die LED leuchtet wenn der PNP Schaltausgang ge ffnet ist Hinweis Insbesondere h ngt das Aufzeichnen von Ereignissen vom Aufleuchten der LED ab siehe Kapitel Diagnosem glichkeiten 4 9 1 BX100022 02 2010 Art Nr 90 32 035 19 Bedienungs und Installationsanleitung Installation and Operation Instruction fi if Nivotemp NT MD 42 ay TECHNOLOGIES 4 8 Analogausg nge 4 8 1 Analogausgang x Zuweisung der oberen Grenze Hier erfolgt die Zuweisung bei welcher Temperatur das maximale Analogsignal ausgegeben werden soll Die Einstellung erfolgt im Men
44. en Tagen statt e ltestes Ereignis Jor6 fand vor x Stunden Tagen statt e L schfunktion dore lt 24h Taste V A dor3 amp Eh Taste V A dor lt Bgh Taste V A dor5 non Taste V A dorb nan Taste V A noch nicht belegt es fanden erst 4 Ereignisse statt _ Taste A l schen dout Der Index des Eintrags x wird im Wechsel mit der Zeit angezeigt z B dor lt 4h f r j ngstes Ereignis vor 1 4 Stunden Best tigen der Anzeige mit der Taste l scht die Ereignisliste und kehrt zum Untermen zur ck Hinweis Falls keine Ereignisse aufgezeichnet wurden wechselt die Anzeige zwischen Jor X und non Die gespeicherten Daten werden nach 6 Monaten berschrieben 4 9 2 Maximale und minimale Temperatur Hier werden die gespeicherte maximale und minimale Temperatur angezeigt oder gel scht Diagnostic A gt Max Min Temp E gt Wahlmen ___ Diagnose Men Max Minwert Speicher ir Die Werte werden in der folgenden Weise angezeigt Beispiel e Maximalwert der Temperatur 12C Taste V e erreicht vor x Stunden Tagen 84h Taste V A e Minimalwert der Temperatur ect Taste V A e erreicht vor x Stunden Tagen z ih Taste W A e L schfunktion Taste A l schen tn Reihenfolge Men Max Wert Zeit Min Wert Zeit l schen Reset Best tigen der
45. ervice and repair is carried out by B hler Technologies GmbH unless described in this manual only original spare parts are used This manual is part of the equipment The manufacturer keeps the right to modify specifications without advanced notice Keep this manual for later use The following warning signs and signal words are used in this manual disconnect from mains Warning against Warning against possible Warning against electrical voltage Warning against hot wear respirator surface P hazardous situation A explosive atmospheres Warning against dap l wear face protection respiration of toxic gases Warning against acid and corrosive substances wear gloves e Q O gt eee 26 BX100022 02 2010 Art Nr 90 32 035 Bedienungs und Installationsanleitung b d Installation and Operation Instruction on Nivotemp NT MD a5 SOFIE TECHNOLOGIES Signal words for warnings NOTE Signal word for important information to the product Signal word for a hazardous situation with low risk resulting in damage to the device or the property or minor or medium injuries if not avoided Signal word for a hazardous situation with medium risk possibly resulting in severe injuries or death if not avoided DANGER Signal word for an imminent danger with high risk resulting in severe injuries or death if not avoided Installation of the d
46. erz gerung ssssssseeeeene ener 17 4 7 5 Schaltausgang x R ckschaltverz gerung ssssseseeeeene ene 17 4 7 6 Schaltausgang x Testen des Schaltausgangs sssssssesseeee een 18 4 7 7 Anzeigefunktion der Status LED ndern sssssssssseeseeene nennen 18 4 8 Analogausg nge an Hnu ea aueh 20 4 8 1 Analogausgang x Zuweisung der oberen Grenze sss enne 20 4 8 2 Analogausgang x Zuweisung der unteren Grenze ssssssssseeeee ene 20 4 8 3 Analogausgang x Festlegen der Signalform ssssseene enne 20 4 8 4 Analogausgang x Testen des Analogausgangs ssssse eee 21 4 9 Diagnosem glichkeiten sssssssssseeseeeeeneneneenen nennen nnn en nennen nennen nennen nnn nens 21 4 9 1 Logbuch aufrufen Em 22 4 9 2 Maximale und minimale Temperatur 44440snsnnennennnnnnnennnnnnnnnnnnnnnennnnnnn essen nnannnnr anne 22 4 9 3 Zu protokollierenden Schaltausgang festlegen u4444444nnnnnnnnnnnnnnnennnnnnnnnnnnnnnennnnnnnnn 23 4 9 4 Verz gerung zur Min Max Speicherung der Temperatur ssseeeeeeen 23 5 Wamung c ee 24 5 1 Service und Reparatur tct htt ntt eo ta dann ia dad te RA RR NB d VR XAR NERA RUN e e AER R A ERR TENERE 24 5 2 Fehlerbeheb ng 2 i eon i ia bd Peine nern 24 6 Entsorgung nennen 24 2 a SP T E a a 45 7 1 DeMi eenn A EEA E 45 7 2 Standard
47. evice shall be performed by trained staff only familiar with the safety requirements and risks Adhere to all relevant safety regulations and technical indications for the specific installation place Prevent failures and protect persons against injuries and the device against damage The person responsible for the system must secure that safety and operation instructions are accessible and followed local accident prevention regulations and standards are obeyed performance data and installation specifications are regarded safety devices are installed and recommended maintenance is performed national regulations for disposal of electrical equipment are obeyed Maintenance and repair Repairs on the device must be carried out by B hler authorized persons only Only perform modifications maintenance or mounting described in this manual Only use original spare parts During maintenance regard all safety regulations and internal operation instructions BX100022 02 2010 Art Nr 90 32 035 27 Bedienungs und Installationsanleitung Installation and Operation Instruction fis i Nivotemp NT MD BUMMER TECHNOLOGIES 3 Mounting DANGER Electrical voltage Electrocution hazard Before opening the cover or working on electrical components disconnect the device from power supply Make sure that the equipment cannot be reconnected to mains unintentionally Installation and maintenance must be carried out b
48. gelb Status Schaltausgang 3 falls vorhanden LED 4 rot Status Schaltausgang 4 falls vorhanden AA Das Schaltverhalten der LED Leuchten bei geschlossenem oder ge ffnetem Schaltkontakt kann ge ndert werden siehe dazu Kapitel 4 7 7 8 BX100022 02 2010 Art Nr 90 32 035 Bedienungs und Installationsanleitung Installation and Operation Instruction B at Nivotemp NT MD A BRUNNER TECHNOLOGIES 4 3 Allgemeine Tastenfunktionen Die Bedienung erfolgt Uber die Tasten unterhalb des Displays Eine ausf hrliche Erkl rung der Men steuerung finden Sie in den folgenden Kapiteln Taste Modus Funktion Messwertanzeige Wechsel der angezeigten Einheiten Beispiel e 10 130L m Men Wechsel in ein untergeordnetes Men Am Ende des Men s Wechsel ins bergeordnete Men E Exit signalisiert das Ende des Men s Nach Eingabe Auswahl Einen eingegebenen Zahlenwert oder eine Funktionsauswahl bestatigen und speichern Messwertanzeige Anzeige der Konfiguration A Im Men Men punkt Zahlenwert oder Funktionsauswahl aufw rts bl ttern Bei gedr ckter Taste erfolgt dies fortlaufend Messwertanzeige Wechsel ins Hauptmen v Im Men Men punkt Zahlenwert oder Funktionsauswahl abwarts blattern Bei gedr ckter Taste erfolgt dies fortlaufend v gt Im Men Verlassen des Haupt Unter Wahlmen s und R cksprung zur
49. gr e Einstellmen OUTX Obere Schaltgrenze X Schaltpunkt f r OUT x 6 P j Hinweis Der Schaltpunkt muss innerhalb der Bereichsgrenzen siehe Men M Einstellbereich 0 C bis 100 C Basiseinstellungen Erweiterte Funktionen gew hlt werden 32 F bis 212 F Falls dem Schaltausgang OUT 1 die Funktion Fenster zugewiesen wurde wird FRI angezeigt Der eingestellte Wert entspricht der oberen Fenstergrenze Falls dem Schaltausgang OUT 1 die Funktion Frequenzausgang zugewiesen wurde wird E LH entspricht der Frequenz 100 Hz angezeigt Der eingestellte Wert 4 7 3 Schaltausgang x Untere Schaltgrenze R ckschaltpunkt Die untere Schaltgrenze f r den Schaltausgang Out 1 wird in folgendem Untermen gesetzt Messgr e Out X nut rPiIFLIFio ____ lq gt y Wahlmen M Hauptmen Messgr e Einstellmen OUTX Untere Schaltgrenze X Labo ah I p R ckschaltpunkt f r OUT 1 si Hinweis Der R ckschaltpunkt muss innerhalb der Bereichsgrenzen gew hlt werden Einstellbereich 0 C bis 100 C Falls dem Schaltausgang OUT 1 die Funktion Fenster zugewiesen wurde 32 F bis 212 F F E wird angezeigt Der eingestellte Wert entspricht der oberen Fenstergrenze Falls dem Schaltausgang OUT 1 die Funktion Frequenzausgang zugewiesen wurde wird E L
50. ie Niveauschalter der Serie Nivotemp NT MD dienen zur berwachung der F llstandes und der Temperatur in Fluidsystemen Je nach Typ sind die Niveauschalter mit unterschiedlichen Schaltausg ngen ausgestattet F r diese Typen stehen die folgenden Optionen zur Verf gung e OV Ovalflansch e G1 Adapter auf G1 Flansch Die Konfiguration Ihres Ger tes entnehmen Sie bitte dem Typenschild Hier finden Sie neben der Auftragsnummer auch den Typenschl ssel und die Typenbezeichnung NT MD 2M12 Baureihe Option Nivotemp NT MD OV Ovalflansch G1 Adapter auf G1 Material 2T MS LED Temperaturanzeige 2 x Temperaturausgang Steckverbindung 4T 2M12 LED Temperaturanzeige 4x Temperaturausgang 1T KT LED Temperaturanzeige 1x Temperaturausgang L nge 1xAnalogausgang max 500 mm Schaltfunktion 2 Kontakt NO fallend Offner Anzahl Niveaukontakte NC fallend Schlie er 1K oder 2K Einbauma L2 mm K Offner SchlieRer 2 Niveaukontakt Nicht verstellbar Schaltfunktion 1 Kontakt Einbauma L1 mm NO fallend ffner 1 Niveaukontakt NC fallend Schlie er 1 1 Einsatzbereich Eine Medientemperatur zwischen 20 C und 80 C 4 F und 176 F muss eingehalten werden Der Niveauschalter darf nicht in leicht entz ndlichen oder tzenden Fl ssigkeiten verwendet werden Im Medium d rfen keine Partikel
51. inen Punkt gekennzeichnet gt Geben Sie mit den Tasten A und V den Code ein und best tigen Sie mit der Taste P Die aktive Ziffer r ckt um eine Stelle nach rechts Nach Eingabe der 3 Ziffer ffnet sich das Hauptmen Bei einer falschen Eingabe des Zifferncodes springt das Ger t zur Messwertanzeige zur ck Falls Sie das Passwort vergessen haben gelangen Sie jederzeit mit dem Mastercode 287 ins Men Sie k nnen die Tastensperre aufheben in dem Sie im Men punkt Loc im Untermen Basiseinstellungen Erweiterte Funktionen bEF den Code mit der Eingabe 000 zur cksetzen 4 5 Men bersicht Die Struktur des Men s ist angelehnt an das Einheitsblatt 24574 ff des VDMA Das Men ist hierarchisch aufgebaut In der obersten Men ebene befinden sich die Hauptmen eintr ge z B LEMP bEF d A E Jedes Hauptmen enth lt weitere Untermen punkte Die Men punkte k nnen je nach Konfiguration des Ger tes variieren Nicht alle im Nachfolgenden beschriebenen Men punkte m ssen auf Ihr Gerat zutreffen Die Konfiguration k nnen Sie abrufen wenn Sie im Anzeigemodus die Taste A dr cken Angezeigt wird ein 4 stelliger Code z B Hierbei bedeuten die 4 Stellen tsav t Typ Temperaturmessung Niveau und Temperaturmessung t o S Anzahl der Schaltausgange 1 2 oder 4 a Anzahl der Analogausg nge 0 oder 1 V Montagetyp der Ger tes Standardmontage Tankeinbau Fernanzeige i F 10 BX10002
52. ion Instruction fis tl Nivotemp NT MD 427 ay TECHNOLOGIES 4 3 Common Key Functions The device is operated by three keys below the display Please refer to the chapters below for detailed descriptions Key Operation Mode Function Normal mode switches the displayed unit example IM l e 10 130L p Within the menu calls a sub menu gt At the end of the menu exits the sub menu Exit indicates the end of the menu After editing selecting accept and store the entered value or selection Normal mode displays the configuration A Within the menu scrolls up menu item or selection increase the displayed value Holding the key changes the value continuously Normal mode calls the main menu v Within the menu scrolls down menu item or selection decrease the displayed value Holding the key changes the value continuously v gt Within the menu exits the main or sub menu and returns to normal mode A gt Within the menu exits the sub menu Within the menu exits the main or sub menu 60 s no action Changed values are not stored if you exit the menu this way To select a menu item and to change a parameter value follow the steps gt Open the main menu with P Select the sub menu using W and A and press to open the selected menu If applicable select the next sub menu using W and A and press P to open it
53. ions assignment of the analog outputs cannot be changed Biagnostie d i In addition menu Diagnostic provides methods for analyzing events Exit E Exit submenu Please refer to the detailed presentation of the menu structure at the end of this document BX100022 02 2010 Art Nr 90 32 035 31 Bedienungs und Installationsanleitung Installation and Operation Instruction fi if Nivotemp NT MD 27 ay TECHNOLOGIES 4 6 Changing general Settings In menu Basic Settings Extended Functions b F general settings are made These settings affect the display of values as well as the options in menus Level and Temperature This menu provides assignment of switching outputs if equipped as level or temperature measurement as well gt Press V to open the main menu gt Select menu item b F using W and A 4 6 1 Setting Unit for Temperature Measurement In this menu the unit for temperature is set Basic EF bEF gt Basic ext functions Set Unit Temp L un P gt Parameter a Unit temperature C F ww The following units are available Eun Parameters degree Celsius degree Fahrenheit FG F Note If the unit is changed all related values as settings of the switching points are re calculated 4 6 2 Setting the Display Refresh Rate Depending on the application the display refresh r
54. iq Bedienungs und Installationsanleitung Installation and Operation Instruction YAURI ERI Nivotemp NT MD TECHNOLOGIES Lesen Sie die Bedienungsanleitung vor dem Gebrauch des Ger tes gr ndlich durch Beachten Sie insbesondere die Hinweise unter Gliederungspunkt 2 Andernfalls k nnten Gesundheits oder Sachsch den auftreten Die B hler Technologies GmbH haftet nicht bei eigenm chtigen nderungen des Ger tes oder f r unsachgem en Gebrauch Read this instruction carefully prior to installation and or use Pay attention particularly to all advises and safety instructions to prevent injuries B hler Technologies can not be held responsible for misusing the product or unreliable function due to unauthorised modifications BX100022 02 2010 Art Nr 90 32 035 i B hler Technologies GmbH Harkortstr 29 D 40880 Ratingen ENA Tel 49 0 21 02 49 89 0 Fax 49 0 21 02 49 89 20 R J Internet www buehler technologies com Email fluidcontrol buehler technologies com 1 Bedienungs und Installationsanleitung Installation and Operation Instruction Nivotemp NT MD Ww a TIRE TECHNOLOGIES Inhaltsverzeichnis Seite 1 Einleitung oen nene innenineoneoneneononeoec obo e on on nOn EO URN ai ORO GEO OR UR 4 1 1 Eins tzbereich u 4 2 4 1 2 Funktionsweise EE 5 1 2 1 Eullstands berwachung iu lee ae une 5 1 2 2 Temperatur berwachurig assisi aai a A aa STAES A S N 5 2 Wichtige AINWEISG X
55. losed d open closed 0 1 0 1 rising closer rising opener falling opener falling closer NO normally open NC normally closed Hna Hnc 4 7 2 Switching Output x Upper Limit Set Point The upper limit for switching output 1 set point is set in sub menu meas aus value z pot us ae E a T i gt p Parameter oH c Set point for OUT 1 S P Note Range The set point must be set within the measuring range see menu Basic 0 C to 100 C extended functions bEF 32 F to 212 F FH If the switching characteristic is set to window is displayed The set value represents the upper window limit If the switching characteristic is set as frequency output F LH is displayed The set value represents a frequency of 100 Hz 4 7 3 Switching output x Lower Limit Reset Point The lower limit for switching output 1 set point is set in sub menu Meas value ____ gt Out X nut pe FEFFE io eee M Parameter ____ Main menu meas value Settings OUTX Restet point X Calo ah I p Reset point for OUT 1 r Note Range The reset point P must be set within the measuring range 0 C to 100 C Ft N 32 F to 212 F If the switching characteristic is set to window is displayed The set value represents the lower window limit Ifthe switching characteristic is set as frequency output F LL a is displayed The set value represents a frequency of 1 Hz 36 BX100022 02 2010 Art Nr 90 32 035 Bedienungs und I
56. m to be recorded Diagnostic J A gt Delay MM Jt gt Parameter im Diagnostics menu Delay storing Min Max B 4100 A Enter the desired delay time dt Range 0 100 seconds BX100022 02 2010 Art Nr 90 32 035 43 Bedienungs und Installationsanleitung Installation and Operation Instruction A if Nivotemp NT MD 427 ay TECHNOLOGIES 5 Maintenance The device works maintenance free 5 1 Service and Repair Risk due to defective device In case of failure switch off the device immediately and repair the fault The device should not be turned on again before elimination of the failure If an error occurs during operation the table below gives hints for troubleshooting If you need help or more information call 49 0 2102 498955 or your local agent Please get the data of the type plate ready for identification If the device doesn t work correctly after elimination of failures and turning power on the device must be checked by the manufacturer Please ship the device with suitable packing to B hler Technologies GmbH Reparatur Service Harkortstrasse 29 40880 Ratingen Germany 5 2 Troubleshooting If an error occurs all outputs are set idle All four LEDs flash Errors are stored until the device is shut off Problem Failure Possible cause Solution No display Mains discon
57. nected Check cables and replace them if necessary Error messages on the display toggles between Err and Exxx e g E GC l e E D D E p D Ambient temperature too low Keep limits according to technical Error 01 data D D c Ambient temperature too high Keep limits according to technical Error 02 data E HH D u Pt 100 RTD defective short cut Replace measurement cable Error 04 Pt 100 RTD Send the device for repair E p D B Pt 100 RTD defective broken Replace measurement cable Error 08 wire Pt 100 RTD Send the device for repair 6 Disposal Regard the local regulations for disposal of electric and electronic equipment 44 BX100022 02 2010 Art Nr 90 32 035 Bedienungs und Installationsanleitung Installation and Operation Instruction Nivotemp NT MD vw BETTER TECHNOLOGIES 7 Anhang 7 1 Definitionen Die Kontaktlage der Niveaukontakte ist wie folgt definiert Beispiel eines Niveauschalters Example of a level switch 7 2 Standard Anschluss 7 Appendix 7 1 Definitions The contact positions of the level contacts are defined as follows Die Kontaktpositionen werden von oben nach unten gemessen Kontakt Nr 1 an Position L1 Kontakt Nr 2 an Position L2 Kontakt Nr 3 an Position L3 USW Hinweis Je nach Modell des Niveauschalters ist die Anzahl der Kontakte begrenzt siehe Typen schl ssel
58. net Damit hangt die Aufzeichnung der Schaltvorg nge von der Einstellung der Schaltfunktion der LEDs ab siehe 4 7 7 Die Einstellungen und die Auswertung k nnen hier vorgenommen werden p Diagnostic d A Diagnose Men i HINWEIS Es kann nur ein Schaltausgang protokolliert werden Der zu protokollierende Schaltausgang wird im Men punkt Schaltausgang Log Alarm SLA gesetzt gt Dr cken Sie die Taste V um ins Hauptmen zu gelangen gt W hlen Sie den Men punkt d A mit den Tasten W und A aus Von hier aus gelangt man zu diversen Diagnosewerten und Protokollierungen d j n zur F llstands und Temperatur berwachung gt ffnen Sie das Men mit der Taste P Nun k nnen Sie die Diagnose Einstellungen andern bzw aufrufen BX100022 02 2010 Art Nr 90 32 035 21 Bedienungs und Installationsanleitung Installation and Operation Instruction Nivotemp NT MD vw 4207 aR TECHNOLOGIES 4 9 1 Logbuch aufrufen Die letzten 6 Ereignisse des protokollierten Schaltausgangs k nnen hier abgerufen oder gel scht werden Diagnostic d A gt Journal Out laut gt Wahlmen Diagnose Men Protokolliert Ausgang dard Die Journaleintrage werden in der folgenden Weise angezeigt Beispiel e J ngstes Ereignis vor fand vor x Stunden h Tagen d statt dor h Taste V e Ereignisse 2 bis 5 fanden vor x Stund
59. nm 40 4 8 3 Analog Output x Setting the Output Characteristic sssssseeee 40 4 8 4 Analog Output x Testing the Analog Output ssssssseeeeem ene 41 4 9 IBI Te efe oda foro m 41 4 9 1 ISTe EUNTEM 42 4 9 2 Maximum and minimum Temperature ssssssssssssseseeeeeneerenen nennen nennen nnns 42 4 9 3 Assigning the Switching Output for recording sssseeeeemm eme 43 4 9 4 Delay for recording min max Temperature ssssssssssseeee enne nemen 43 5 MaintenarcCce eii enr rente ta tuu on Eno nenne oa Pa E ESEN RARE Y a aia ai 44 5 1 Isaac 44 5 2 Miei 44 EE DISPOSAl T 44 AE Opp 45 7 1 BID 45 7 2 Standard Pin Assignment sse eene nennen ener enne en nennen nennen nnns 45 7 3 Technical Data rendere be de ex dee a exe d e e dea 46 7 4 Technical Data of Contacts sssssssssssssssseseseee ene nrnn ener nennen ener nennen 46 7 5 Dimensions eens eek 47 7 6 Actual settings 48 7 7 Overview Menu Str ctUre conii eter iet ce EL eee dps eet ene ae a aan kennen 51 BX100022 02 2010 Art Nr 90 32 035 3 Bedienungs und Installationsanleitung Installation and Operation Instruction fi af Nivotemp NT MD BUMMER TECHNOLOGIES 1 Einleitung D
60. nstallationsanleitung Installation and Operation Instruction Ww Nivotemp NT MD A XTIVTLISTRY TECHNOLOGIES 4 7 4 Switching Output x Delay for Set Point Menu Extended Functions EF1 provides further settings for switching output 1 The menu is located on the second sub menu level The delay time for set point and reset point avoids too many false alarms in case of fluctuating conditions The delay for the set point is set in the following menu Meas value ____ gt p Out X nut gt pEF X ER y Delay SPX d5_ P gt Parameter re Main menu meas value Settings OUTX Extenden functions Delay for OUTX on Go ia Time in seconds which the signal must at least remain to enable the switch to d 6 l operate Note Range Ifthe output characteristic is set to Window the value represents the time 0 100 seconds delay for the signal remaining within the measurement window Ifthe output characteristic is set to Frequency Output this value has no effect 4 7 5 Switching Output x Delay for Reset Point The delay for the set point is set in the following menu Meas value ____ gt gout X ouk gt pEF X EE y Delay RPX cdr_ k gt Parameter ER Main menu meas value Settings OUTX Extenden functions Delay for OUTX off Gg ia Delay for reset p
61. oint OUT x d r l Time in seconds which the signal must at least remain to enable the switch to operate Range Note Ifthe output characteristic is set to Window the value represents the time delay for the signal leaving the measurement window Ifthe output characteristic is set to Frequency Output this value has no effect 0 100 seconds BX100022 02 2010 Art Nr 90 32 035 37 Bedienungs und Installationsanleitung Installation and Operation Instruction Nivotemp NT MD vw mr UI La TECHNOLOGIES 4 7 6 Switching Output x Testing the switching output The switching output can be tested in the following menu Meas value ____ gt Out X nut EF X EF Check Out X au Parameter Main menu meas value gt Settings OUTX ul Extenden functions gt Test for OUTX nof an Testing the switching output The following options are available if ou is set to Hno Hnc Fna I Fac no P oFF on normal operation turns the switching turns the switching output off output on Lou The following options are available if ou is set to FA B output frequency 1 Hz F i00 output frequency 100 Hz n oP normal operation as frequency output Note After finishing the tests make sure to reset the function to normal operation nof 4 7 7 Switching O
62. otemp NT MD u B HLER TECHNOLOGIES 4 9 1 Open the Journal The last 6 events of the switching output are listed and can be deleted Diagnostic lt A gt Journal Out ifowt gt Parameter ee Diagnostics menu Display recorded output dar i The journal entries are listed as follows Example e Most recent event Jor occurred x hours h days d ago dor 3h press V e Events 2 to 5 occurred x hours h days d ago dore 24h press V A e Oldest event Joc 5 occurred x hours h days d ago dor3 amp 6th press V A e Delete Jor 4 amp 2h press V A dor5 non press V A dorb non press V A press A delete not yet recorded only 4 events occurred until now 7 The display toggles between index of event x and the time it occurred e g U Oo U t dor 3h recorded the latest event 1 4 hours ago Accepting with gt deletes the journal and returns to the sub menu Note f no event was recorded the display toggles between Jor x and nan The stored data is overwritten after six months 4 9 2 Maximum and minimum Temperature The recorded maximum and minimum level can be displayed or deleted Diagnostic d A gt Max Min Temp 1 7 4 gt Parameter Diagnostics menu Max Min memory MUS SS The values are listed as follows Ex
63. r Technik Beugen Sie St rungen vor und vermeiden Sie dadurch Personen und Sachsch den Der f r die Anlage Verantwortliche muss sicherstellen dass Sicherheitshinweise und Betriebsanleitungen verf gbar sind und eingehalten werden Unfallverh tungsvorschriften der Berufsgenossenschaften beachtet werden in Deutschland Allgemeine Vorschriften VBG 1 und Elektrische Anlagen und Betriebsmittel VBG 4 die zul ssigen Daten und Einsatzbedingungen eingehalten werden Schutzeinrichtungen verwendet werden und vorgeschriebene Wartungsarbeiten durchgef hrt werden bei der Entsorgung die gesetzlichen Regelungen beachtet werden Wartung Reparatur Reparaturen an den Betriebsmitteln d rfen nur von B hler autorisiertem Personal ausgef hrt werden Nur Umbau Wartungs oder Montagearbeiten ausf hren die in dieser Bedienungs und Installationsanleitung beschrieben sind Nur Original Ersatzteile verwenden Bei Durchf hrung von Wartungsarbeiten jeglicher Art m ssen die relevanten Sicherheits und Betriebsbestimmungen beachtet werden 6 BX100022 02 2010 Art Nr 90 32 035 Bedienungs und Installationsanleitung Installation and Operation Instruction c Nivotemp NT MD BUMMER TECHNOLOGIES 3 Aufbauen und Anschlie en GEFAHR Elektrische Spannung Gefahr eines elektrischen Schlages Trennen Sie das Ger t bei allen Arbeiten vom Netz Sichern Sie das Ger t gegen unbeabsichtigtes Wiedereinsch
64. rnung vor einer allgemeinen Gefahr Warnung vor explosions gef hrdeten Bereichen Netzstecker ziehen Atemschutz tragen Warnung vor elektrischer A Warnung vor hei er Spannung Oberfl che Gesichtsschutz tragen Warnung vor dem Einatmen giftiger Gase Warnung vor tzenden Fl ssigkeiten Handschuhe tragen pp Qoo BX100022 02 2010 Art Nr 90 32 035 5 Bedienungs und Installationsanleitung b d Installation and Operation Instruction cxi Nivotemp NT MD u B HLER TECHNOLOGIES Signalw rter f r Warnhinweise Signalwort f r wichtige Information zum Produkt auf die im besonderen Ma e aufmerksam gemacht werden soll Signalwort zur Kennzeichnung einer Gef hrdung mit geringem Risiko die zu einem Sachschaden oder leichten bis mittelschweren Verletzungen f hren kann wenn sie nicht vermieden wird Signalwort zur Kennzeichnung einer Gef hrdung mit mittlerem Risiko die m glicherweise Tod oder schwere Verletzungen zur Folge hat wenn sie nicht vermieden wird Signalwort zur Kennzeichnung einer Gef hrdung mit hohem Risiko die unmittelbar Tod oder schwere Verletzung zur Folge hat wenn sie nicht vermieden wird Das Ger t darf nur von Fachpersonal installiert werden das mit den Sicherheitsanforderungen und den Risiken vertraut ist Beachten Sie unbedingt die f r den Einbauort relevanten Sicherheitsvorschriften und allgemein g ltigen Regeln de
65. ro SchlieRer Frac ffner gt Zeitt gt Zeitt mw Zeitt Frequenzausgang Ff Frequenzausgang Ist der Ausgang als Frequenzaus gang definiert wird ein Rechteck signal mit einer Frequenz zwischen 1 Hz und 100 Hz proportional zum Messwert ausgegeben Hinweis Um die Flankensteilheit des Rechtecksignals zu erh hen wird empfohlen den Schaltausgang mit einem 10 kO Widerstand zu belasten Beispiel F La 15 C F iH 80 C A 24 V mit Temperatur T und Frequenz f lt m T Filo entspricht f 1Hz gt Zeitt 24 V T 47 5 C entspricht f 50Hz LIL 24 V um F000575 gt Zeitt BX100022 02 2010 Art Nr 90 32 035 15 Bedienungs und Installationsanleitung Installation and Operation Instruction fi af Nivotemp NT MD BUMMER TECHNOLOGIES Hinweis Die Schaltfunktion kann unterschiedlich bezeichnet sein SP SP P rP gt gt offen geschlossen offen geschlossen 0 1 0 1 steigend Schlie er steigend ffner fallend Offner fallend Schlie er NO normally open NC normally closed Hno Hnc 4 7 2 Schaltausgang x Obere Schaltgrenze Einschaltpunkt Die obere Schaltgrenze f r den Schaltausgang Out X wird in folgendem Untermen gesetzt y Wahlmen Ee Colo oh 3 Messgr fe ____ gt Out X nut HSP I FHI FH mem Hauptmen Mess
66. rz 2010 Stefan Eschweiler Technischer Leiter technical manager KX 10 0020 Tel 49 0 21 02 49 89 0 Fax 49 0 21 02 49 89 20 Buhler Technologies GmbH Harkortstr 29 D 40880 Ratingen Internet www buehler technologies com
67. stellung von ou auf Hao Hac Fra I Frc noP off on Normalbetrieb des Schaltausgang Schaltausgang dauerhaft Schaltausgangs dauerhaft ausschalten einschalten Wahlm glichkeiten bei Einstellung von ou auf Ff noP EBEE EREB Normalbetrieb als Ausgabe Ausgabe Frequenzausgang Frequenz 1 Hz Frequenz 100 Hz Hinweis Stellen Sie die Funktion nach Beendigung des Tests unbedingt auf Normalbetrieb a ein 4 7 7 Anzeigefunktion der Status LED ndern Der Schaltzustand des Ausgangs wird durch die LEDs im Display signalisiert Die Zuordnung der LED zum Schaltausgang geht aus folgender Tabelle hervor Nummerierung LED Schaltausgang x Zuordnung bei Zuordnung bei Zuordnung bei 1 Schaltausgang 2 Schaltausg ngen 4 Schaltausg ngen LED 1 LED 1 gelb LED 1 gelb LED 1 gelb 1234 2 LED 2 rot LED 2 rot sooo 3 LED 3 gelb 4 LED 4 rot In der Werkseinstellung zeigt die LED den physikalischen Zustand des PNP Schaltausgangs an Schaltausgang geschlossen LED leuchtet M glicherweise soll die logische Funktion der Anzeige anders erfolgen als das physikalische Signal auf dem Schaltausgang Sie k nnen daher diese Anzeige in diesem Men punkt auch umkehren Schaltausgang ge ffnet LED leuchtet Beispiel anhand der Temperatur Sie haben 2 Schaltausgange f r die Temperatur die folgenderma en eingestellt sind e Oberer Schaltkontakt Max Kontakt
68. t werden FO00464D Schutzdiode z B 1N4007 Gleichspannung DC Schutzdiode parallel zur Last Die Temperatur Schaltausgange sind als PNP Transistor ausgef hrt siehe 24V Abbildung Hinweis Bei Messungen des Schaltausgangs mit hochohmigen Messger te d eingangen oder bei Nutzung als Frequenzausgang ist ein 10 kQ Widerstand zwischen Ausgang und Masse GND zu schalten um Fehlmessungen ma vorzubeugen F000588x Die Versorgungsspannung sowie die Anschlussbelegung entnehmen Sie bitte den Anschlusstabellen in Kapitel 7 BX100022 02 2010 Art Nr 90 32 035 7 Bedienungs und Installationsanleitung Installation and Operation Instruction A A Nivotemp NT MD 427 LY TECHNOLOGIES 4 Betrieb 4 1 Einschalten Wenn im laufenden Betrieb eine Fehlermeldung im Display erscheint betrachten Sie bitte Kapitel 5 2 Fehlerbehebung Nach dem das Ger t an die Versorgungsspannung angeschlossen wurde erscheint zu Beginn kurzeitig die Softwareversion Direkt im Anschluss wechselt das Display zur Messwertanzeige Im Folgenden wird die Funktion der Anzeige und Steuereinheit beschrieben 4 2 LED Statusanzeigen Leuchtdioden oberhalb der Messwertanzeige signalisieren den Status der Temperatur Schaltausg nge Die LEDs sind den Schaltausg ngen fest zugeordnet Die folgende Tabelle zeigt die Werkseinstellungen LED 1 gelb Status Schaltausgang 1 LED 2 rot Status Schaltausgang 2 falls vorhanden LED 3
69. teresefunktion Hno Hysteresefunktion als SchlieRer Hnc Hysteresefunktion als Offner Schlie er oder Offner Funktion bei der beim Uberschreiten des einge stellten Schaltpunktes das Ausgangs signal gesetzt wird Beim Unterschrei ten des eingestellten R ckschaltpunk tes wird das Ausgangssignal gel scht Schlie er bedeutet hier dass der PNP Schaltausgang oberhalb des Schaltpunktes SPx geschlossen ist und bei Unterschreiten des R ck schaltpunktes rPx wieder ffnet ffner bedeutet hier dass der PNP Schaltausgang oberhalb des Schalt punktes SPx ge ffnet ist und bei Unterschreiten des R ckschaltpunktes rPx wieder schlie t Siehe auch die Erl uterungen in der Zeichnung unten Hna SchlieRer 0 Hnc Offner Hysterese SP P Zeitt gt Zeitt 1 F000573 Fensterfunktion Fro Fensterfunktion als Schlie er Fnc Fensterfunktion als Offner Schlie er oder Offner Funktion mit der ein Signalfenster festgelegt wird Bei Erreichen des Messfensters wird das Ausgangssignal gesetzt beim Verlassen wieder gel scht Schlie er bedeutet hier dass der PNP Schaltausgang geschlossen ist wenn sich der Wert innerhalb des Fensters befindet Sonst ist der Schaltausgang ge ffnet ffner bedeutet hier dass der PNP Schaltausgang ge ffnet ist wenn sich der Wert innerhalb des Fensters befindet Sonst ist der Schaltausgang geschlossen F
70. tur C F t Celsius F Fahrenheit AV Display Rate z 5 k gt Wahlmen Wahl der Anzeigeaktualisierungsgeschwindigkeit Anzeigegeschwindigkeit FASE off FASE schnell MEd medium Sta langsam off Anzeige aus AV Lack Davies bas gt Wahimenu Aktivieren einer Tastensperre durch Setzen eines Zifferncodes gt 3 Mastercode 287 Sperren der Taster o 999 AV AV gt Exit E Verlasse Men ebene Darstellung der letzten 6 Alarme L schfunktion Diagnostic A gt Journal Out out gt Wahlmen i ERE Ws Anzeige zeigt die vergangene Zeit in Stunden Tagen Diagnose Men Protokolliert Ausgang dard Wachee zwischen Alarme durch A Y AV Max Min Temp EN gt Wahlmen Darstellung der Grenzwerte L schfunktion Max Min Speich ets ee Anzeige Wert vergangene Zeit in Stunden Tagen L ax m nne er o Wechsel zwischen Werte und Zeit durch A V Set Jornal Out 5 s a omal QUE Fans Wahinenu we Auswahl des zu protokollierenden Alarmausganges berwachung Ausgang Got Dot AV AV Delay MM oii gt Wahlmen Zeit die das Signal angestanden haben mu bis der Maximal Minimalwert gespeichert wird Verz gerung Min Max DB IDD Einstellbereich 0 100 Sekunden A Y gt Exit E Verlasse Men ebene ww gt Exit E Verlasse Men ebene 7 7 Overview Menu Stru
71. ung wird in folgendem Men eingestellt Messgr e ____ gt OutX BUE gt pEF X EF gt Delay RP X dr _ k gt gWahimenii m Hauptmen Messgr e Einstellmen OUTX Erweiterte Funktionen Verz gerung OUTX Aus D UU Verz gerung des R ckschaltsignals f r OUT x d C l Zeitspanne in Sekunden in der das Signal kontinuierlich anliegen muss damit der Schaltausgang anspricht Einstellbereich 0 100 Sekunden Hinweis Falls dem Schaltausgang OUT 1 die Funktion Fenster zugewiesen wurde entspricht der eingestellte Wert der Einschaltverz gerung die ein g ltiges Verlassen des Messfensters detektiert Falls dem Schaltausgang OUT 1 die Funktion Frequenzausgang zugewiesen wurde hat dieser Wert keine Auswirkung BX100022 02 2010 Art Nr 90 32 035 17 Bedienungs und Installationsanleitung Installation and Operation Instruction fi il Nivotemp NT MD BUMMER TECHNOLOGIES 4 7 6 Schaltausgang x Testen des Schaltausgangs Ein Test des Schaltausgangs kann in folgendem Men gestartet werden Messgr e gt gout X nut pEF X ER gt Check Out X Lou gt y Wahlmen PEE Hauptmen Messgr e Einstellmen OUTX Erweiterte Funktionen Funktionstest OUTX nof an Testm glichkeit f r den Schaltausgang Lo U l Wahlm glichkeiten bei Ein
72. ure Note q If the switching output is measured with high impedance measuring equipment or if the frequency output is used connect a 10 kO resistor between output and e ground to avoid faulty measurements i F000588x For supply voltage and pin assignment refer to tables in chapter 7 28 BX100022 02 2010 Art Nr 90 32 035 Bedienungs und Installationsanleitung Installation and Operation Instruction b af Nivotemp NT MD EURER TECHNOLOGIES 4 Operation 4 1 Switching on If an error message occurs during normal operation please refer to chapter 5 2 Troubleshooting After connecting the device to the mains the software version is displayed for a short time Afterwards the measured values are displayed 4 2 LED Status Display Light emitting diodes above the reading indicate the switching state of the outputs The LEDs are assigned to the switching output numbered the same The following table shows the factory settings LED 1 yellow indicates switching output 1 LED 2 red indicates switching output 2 if equipped LED 3 yellow indicates switching output 3 if equipped LED 4 red indicates switching output 4 if equipped EE The switching behavior of the LED ON at closed or opened switching output can be changed see chapter 4 7 7 BX100022 02 2010 Art Nr 90 32 035 29 Bedienungs und Installationsanleitung Installation and Operat
73. urnal with A V Display of min and max temperature and reset Display value elapsed time in hours days scroll with A V Selecting the output to be recorded Time in seconds which the signal must at least remain to store minimum and maximum value Range 0 100 seconds no function with frequency output 52 EG Konformit tserkl rung EE EC declaration of conformity 4207 TUF TECHNOLOGIES Hiermit erklaren wir dass die nachfolgenden Produkte den wesentlichen Anforderungen der folgenden EG Richtlinie in ihrer aktuellen Fassung entsprechen Herewith we declare that the following products correspond to the essential requirements of the following EC directive in its actual version 2004 108 EG EMV EMC Produkte products Niveauschalter und geber Level switches and gauges Typ en type s Nivotemp 61D 63 64 64D 67XP MD Nivovent 71D 73 74 74D 77XP Zur Beurteilung der Konformitat wurden folgende harmonisierte Normen in aktueller Fassung herangezogen The following harmonized standards in actual revision have been used e EN 61326 1 Elektrische Mess Steuer Regel und Laborger te EMV Anforderungen Teil 1 Allgemeine Anforderungen Dokumentationsverantwortlicher f r diese Konformit tserkl rung ist der Unterzeichnende mit Anschrift am Firmensitz The person authorised to compile the technical file is the one that has undersigned and is located at the company s address Ratingen den 05 Ma
74. ut2 rP Einstellung des R ckschaltpunktes FL Festlegung der unteren Fenstergrenze F ito Zuweisung eines Wertes der Frequenz 1 Hz Nur OUT1 und OUT2 Zeit die das Signal angestanden haben mu bis Ausgang OUT1 einschaltet Einstellbereich 0 100 Sekunden bei Frequenzausgang ohne Funktion Zeit die das Signal angestanden haben mu bis Ausgang OUT1 zur ckschaltet Einstellbereich 0 100 Sekunden bei Frequenzausgang ohne Funktion Definition des Schaltverhaltens von Ausgang 1 Hno Hnc Hysteresefunktion SchlieRer oder Offner Fna Fac Fensterfunktion Schlie er oder Offner n Frequenzausgang 1 100Hz naP Normalbetrieb des Schaltausgangs oFF Schaltausgang Aus Fi Simulation 1Hz on Schaltausgang Ein F IUG Simulation 100Hz iz o LED Ausgang folgt dem Schaltausgang Lz o LED Ausgang invertiert zum Schaltausgang Setzen des maximalen analogen Ausgangssignals auf definiertem Wert Hinweis Max Min gt 10 vom Messbereich Setzen des minimalen analogen Ausgangssignals auf definiertem Wert Hinweis Max Min gt 10 vom Messbereich Wahl der analogen Ausgangsfunktion 4 4 20 mA ay D Ls u amp 0 10V 0 Ej Ud Ww naP Normalbetrieb des Analogausgangs HRLF Ausgabe mittlerer Analogwert ta Ausgabe oberster Analogwert Ausgabe unterster Analogwert Alternativmen bei Variante mit Analogausgang Temperatur i gt Outi out gt SPI FHi Fih gt Wahlmen Men Temperatur Einstellmen
75. utput x Changing Switching Function of LED The indication of the switching output by the respective LED can be changed The assignment of each LED is listed in the table Number of LED Switching output x 1 switching output 2 switching outputs 4 switching outputs LED 1 LED 1 yellow LED 1 yellow LED 1 yellow 1234 2 LED 2 red LED 2 red L 3 LED 3 yellow 4 LED 4 red With factory settings the LED indicates the physical switching state of the PNP output output is closed LED is active If requested it is possible to alter the logic function of the LED with respect to the physical signal of the output Therefore the function of the LED can be inverted in this menu item output is opened LED is active Example for temperature control Two switching outputs are available for temperature control with the following settings e Upper switching point maximum NO contact The LED lights up if the maximum temperature is exceeded and temperature if off limits The status indicated is Error if the LED in active ON e Lower switching point minimum NO contact The LED lights up if the minimum temperature is exceeded factory setting In this case the LED would be active ON if no error is present status OK The following table shows an example with factory settings and inverted function for LED3 The switching points are defined as follows 38 BX1000
76. y trained staff only Regard correct mains supply DANGER Toxic and corrosive gases Sample gas can be hazardous Protect yourself during maintenance against toxic corrosive gases Use gloves respirator and face protector under certain circumstances The level switch is delivered pre assembled and can be directly screwed to the tank The float must move freely and must keep enough distance to the walls and to other equipment installed If the float had been demounted make sure that the magnet inside the float is placed above the surface Check its position using a piece of iron It is assumed that the level switch is installed into an empty tank Therefore operating positions is reached after filling the tank The level contacts are installed as NO or NC contact at positions according to your order Position and switching function can not be changed Technical note Extension of lifetime of Reed contacts level According to the design Reed contacts are highly reliable components with a long life time Nevertheless you should take the following remarks into account contact Contact protection n Inductive loads In order to reduce the high reverse voltage produced when the reed switch opens the following contact protection shall be applied F000161E diode such as 1N4007 load DC voltage A diode in parallel to the load The temperature switching outputs are designed as PNP transistor outputs 24V see fig