Home
00108875 / Photoelektronischer Rauchmelder "GS 508" mit
Contents
1. the instruction manual or the package indicates that a product is subject to these regulations By recycling reusing the materials or other forms of utilising old devices Batteries you are making an important contribution to protecting our environment 14 Manufacturer and Licensee Ningbo Siterwell Electronics Co Ltd No 76 Haichuan Road Chuangye Zone B Jiangbei Ningbo China Distributed by Hama GmbH amp Co KG 86652 Monheim Germany www hama com C 0786 CPR 21388 p u G 214063 All listed brands are trademarks of the corresponding companies Errors and omissions excepted and subject to technical changes Our general terms of delivery and payment are applied 00108875 10 15 00 108875 THE SMART SOLUTION Smoke alarm device GS 508 Rauchwarnmelder N Operating Instructions Bedienungsanleitung ID k Vielen Dank dass Sie sich f r ein Hama Produkt entschieden haben Nehmen Sie sich Zeit und lesen Sie die folgenden Anweisungen und Hinweise zun chst ganz durch Bewahren Sie diese Bedienungsanleitung anschlie end an einem sicheren Ort auf um bei Bedarf darin nachschlagen zu k nnen Sollten Sie das Ger t ver u ern geben Sie diese Bedienungsanleitung an den neuen Eigent mer weiter 1 Erkl rung von Warnsymbolen und Hinweisen Wird verwendet um Sicherheitshinweise zu kennzeichnen oder um Aufmerksamkeit auf besondere Gefahren und Risiken zu lenken Wird verwendet um zus t
2. 1 Aktivierung beschrieben 6 Betrieb 6 1 Der Fluchtplan Empfehlung Besprechen und erstellen Sie gemeinsam mit Ihrer Familie und oder Ihren Mitbewohnern einen Fluchtplan Planen Sie wenn m glich auch alternative Fluchtrouten ein da ein Brand Standardrouten blockieren kann F hren Sie Ihrer Familie und oder Mitbewohnern den Alarm des Rauchwarnmelders vor siehe 7 2 Alarmsimulation und stellen Sie sicher dass jeder wei was im Alarmfall zu tun ist Stellen Sie sicher dass auch Ihre Kinder in der Lage sind einen Alarmfall zu erkennen und sich selbst in Sicherheit bringen zu k nnen Bestimmen Sie einen Ort au erhalb Ihres Hauses als Treffpunkt f r den Alarmfall ben Sie ggf das Verhalten im Alarmfall in regelm igen Abst nden Die bung hilft Ihrer Familie und oder Mitbewohnern im Alarmfall das Haus schnell und geordnet zu verlassen 2 Alarmfall m Alarmfall sobald der Rauchwarnmelder Verbrennungspartikel wahrnimmt oder bei Durchf hrung der Simulation siehe 7 2 Alarmsimulation blinkt die LED einmal pro Sekunde und ein Alarmsignal ert nt Alarmsignal Tonfolge 3x Signalton kurze Pause 3x Signalton kurze Pause 3x Signalton Der Alarm dauert so lange an bis der Rauchwarnmelder keine Verbrennungspartikel mehr in der Luft wahrnimmt Sie im Falle eines Fehlalarms den Stummschaltmodus aktivieren siehe 6 4 Stummschaltmodus oder die Alarmsimulation beenden Die Ausl sung eines Alarms erforder
3. Sie sich wie in 6 3 Verhalten im Alarmfall Empfehlung beschreiben e Sobald Sie sichergestellt haben dass es sich um einen Fehlalarm handelt dr cken Sie die TEST Taste des Rauchwarnmelders um den Alarm f r ca 10 Minuten stumm zu schalten e Die rote LED wird dann einmal alle 8 Sekunden blinken um anzuzeigen dass sich der Alarm des Rauchwarnmelders im Stummschaltmodus befindet e Der Rauchwarnmelder wird nach ca 10 Minuten automatisch zur ckgesetzt Falls nach diesem Zeitraum immer noch Rauchpartikel vorhanden sind wird der Alarm erneut ausgel st Der Stummschaltmodus kann wiederholt bet tigt werden 7 Wartung und Pflege 7 1 Test Dr cken Sie die TEST Taste am Rauchwarnmelder Der Signalton ert nt wenn Elektronik Sensor Horn und Batterie funktionieren Ersetzen Sie nicht mehr korrekt funktionierende Rauchwarnmelder sofort durch neue Ger te Es wird empfohlen das Ger t w chentlich zu testen um eine ordnungsgem e Funktion zu gew hrleisten Testen Sie den Rauchwarnmelder NUR mithilfe der TEST Taste Verwenden Sie niemals eine offene Flamme Feuerzeuge etc um einen Alarmfall zu simulieren und die Funktion zu testen 7 2 Alarmsimulation Dr cken und halten Sie die TEST Taste am Rauchwarnmelder um den Alarmfall zu simulieren Wie im Alarmfall blinkt die LED einmal pro Sekunde und ein Alarmsignal ert nt solange bis Sie die TEST Taste wieder loslassen 7 3 Batterie Austausch des Rauchwarnmelders D
4. measure the supplied anchors before and drill approx 25 30 mm deep so that the anchors can be inserted Insert the anchors for cement or brick Mount the base plate of the smoke alarm using the supplied screws holes in the ceiling or wall I plastic anchors holder TER 1S 5 Putting into operation 5 1 Activation The smoke alarm must be activated prior to use Press and hold the TEST button on the smoke alarm for ca 3 4 secs until the LED lights up hen immediately release the TEST button The smoke alarm will generate a short signal sound to indicate successful activation After this check the functionality by pressing the TEST button This check must generate an immediate alarm signal f no alarm signal is generated upon pressing the TEST button the smoke alarm is not activated Repeat the activation until the smoke alarm reacts correctly to the test Upon successful activation and during correct function the LED keeps flashing briefly every 40 seconds 2 Fastening the Smoke Alarm Fasten the smoke alarm to the base plate mounted in the installation location by guiding the snap in hooks into the intended openings and clockwise rotation of the smoke alarm uw e Check the secure fastening of the smoke alarm to the base plate e After its mounting the correct function of the smoke alarm must be tested For testing press the TEST button An alarm signal is generated f no s
5. mode is activated see 6 4 Alarm Silencing Mode or the alarm simulation is ended The triggering of an alarm always necessitates your immediate attention and the initiation of adequate measures se tenn a 6 3 Behaviour in the Event of Alarm Recommendation Rescue Yourself and Others e Remain calm e Warn other family members and or cohabitants Immediately leave the building and close all doors and windows on your escape route if it is safe to do so to restrict the spread of smoke and fire After leaving the house go to your prearranged meeting place and ensure that all persons have left the house Call the Fire Service e Call the fire service as soon as you are in safety Attempts to Extinguish the Fire e Only initiate attempts to extinguish the fire on your own if you do not endanger yourself or others and if you have adequate extinguishing appliances at your disposal 6 4 Alarm Silencing Mode for false alarms Prior to activating the alarm silencing mode determine the cause for the alarm and make sure that there is no further danger Cigarette smoke will generally not trigger the alarm unless the smoke is blown directly into the smoke alarm e Cooking vapours can trigger an alarm if the smoke alarm is located near a cooking area If an alarm is triggered verify whether or not a genuine emergency situation exists If fire or smoke is present call the fire service and behave in
6. o Ammer J Keller Werkstatt rae LED TEST Taste x 4 F r die Mindestabsicherung wird empfohlen je einen Rauchwarnmelder im Flur und Treppenhaus jeder Etage sowie in jedem Schlaf und Kinderzimmer zu installieren siehe Bild 2 und 3 e Um einen optimalen Schutz zu erreichen installieren Sie Rauchwarnmelder in allen R umen Fluren Keller Speicherr umen etc ber cksichtigen Sie 4 2 Montageorte mit Einschr nkungen In Geb uden mit mehreren Wohneinheiten sollte die Installation von Rauchwarnmeldern in jeder Wohneinheit separat sowie in den gemeinsamen Fluren und Treppenh usern erfolgen Bringen Sie den Rauchwarnmelder in Treppenh usern ganz oben an da hier eine Kaminwirkung vorhanden sein kann die den Rauch schnell in die oberen Stockwerke ziehen l sst Achten Sie bei der Montage darauf dass der Rauchwarnmelder mindestens 50 cm von jeder Seiten wand und gr eren Einrichtungsgegenst nden z B hohe Schr nke entfernt ist siehe Bild 1 Die angegebenen Montageorte sowie dargestellten Positionen der Rauchwarnmelder sind nur beispielhaft auf Grundlage durchschnittlicher Wohnungen und H user erstellt und sollen nur als Anhaltspunkt dienen Die Montage des Rauchwarnmelders sollte von einer zugelassenen und qualifizierten Elektrofachkraft durchgef hrt werden Beachten und befolgen Sie alle lokalen und nationalen Elektro und Bauvorschriften f r die Installation 4 2 Montageort
7. 00 108875 THE SMART SOLUTION Smoke alarm device GS 508 Rauchwarnmelder Operating Instructions Bedienungsanleitung ID k Thank you for choosing a Hama product Take your time and completely read the following instructions and information Please keep these instructions in a safe place for future reference If you sell the device please pass these operating instructions on to the new owner 1 Explanation of Warning Symbols and Notes This symbol is used to indicate safety instructions or to draw your attention to specific hazards and risks This symbol is used to indicate additional information or important notes 2 Package Contents Photoelectronic smoke alarm with VdS test mark Base plate Mounting equipment 3 volt CR123A battery Lithium permanently integrated These operating instructions Safety Notes Do not use the smoke alarm in the immediate vicinity of heaters other heat sources or in direct sunlight Do not drop the smoke alarm and do not expose the device to major shocks Do not open the smoke alarm or continue to operate it in case of any damage To ensure the correct function of the smoke alarm follow the mounting and installation information given in these operating instructions Replace the smoke alarm in case of any damages Create an emergency escape plan for further information please refer to 6 1 Emergency Escape Plan Recommendation Attention hearing damage poss
8. bel ein Beton oder Mauerwerk Befestigen Sie die Grundplatte des Rauchwarnmelders mit den beigelegten Schrauben cher in e oder Wins Plasiikdade 5 Inbetriebnahme 5 1 Aktivierung Der Rauchwarnmelder muss vor Gebrauch aktiviert werden Dr cken und halten Sie die TEST Taste f r ca 3 4 Sek bis die LED aufleuchtet Lassen Sie dann unverz glich die TEST Taste los Der Rauchwarnmelder signalisiert mit einem kurzen Signalton dass die Aktivierung erfolgreich war berpr fen Sie anschlie end die Funktion mit einem Druck auf die TEST Taste Es muss ein soforti ger Signalton ert nen Ert nt beim Dr cken der TEST Taste kein Signalton ist der Rauchwarnmelder nicht aktiviert Wiederholen Sie die Aktivierung bis der Rauchwarnmelder richtig auf den Test reagiert Nach erfolgreicher Aktivierung und bei ordnungsgem er Funktion blinkt die LED ca alle 40 Sek kurz auf 5 2 Montage des Rauchwarnmelders e Befestigen Sie den Rauchwarnmelder auf der an der Montagestelle angebrachten Grundplatte indem Sie die Rasthaken in die vorgesehenen ffnungen einf hren und den Rauchwarnmelder im Uhrzeigersinn drehen e Kontrollieren Sie ob der Rauchwarnmelder sicher auf der Grundplatte befestigt ist e Nach der Installation muss der Rauchwarnmelder auf Funktion gepr ft werden Dr cken Sie dazu die TEST Taste Ein Signalton ert nt Ert nt kein Signalton wiederholen Sie den Aktivierungsvorgang wie in 5
9. e 40 C or the air humidity reaches more than 93 are not suitable for installation Do not install the smoke alarm on e g the ceiling of caravans or similar rooms Sunlight will quickly heat up the air and prevent any smoke from penetrating and triggering the smoke alarm n very dirty dusty or grimy areas or in areas with insect infestation smoke alarms can be exposed to pol ution by excess levels of dirt and dust which can result in false alarms or impairment of smoke detection Generally the alarm signal of the smoke alarm is loud enough to warn persons However situations may arise in which the persons are unable to hear e g high ambient noise level persons with very deep sleep and or hearing impairment persons under the influence of drugs or alcohol etc Install additional special smoke alarms if you suspect this being the case with people in your environment 4 3 Mounting the Base Plate Hold the base plate of the smoke alarm against the installation location the two mounting holes can be used as a template to mark the positon of the drill holes Prior to drilling and mounting make sure that there are no electricity water gas or any other supply lines in the area of the installation location e On wooden ceilings or exposed beams drill holes with a depth of approx 20 mm using a 2 5 mm drill bit Use the supplied screws without the anchors For cement or brick use a drill bit with a maximum diameter of 5 mm
10. e mit Einschr nkungen In K chen und Nassr umen Badezimmer sind Rauchwarnmelder nur dann anzubringen wenn die Einschr nkungen aus Bild 1 beachtet und gleichzeitig Fehlalarme durch K chen und Wasserdampf ausgeschlossen werden k nnen Halten Sie bei der Installation des Rauchwarnmelders in der N he von Geschirrsp lern Waschmaschi nen fen etc mindestens 3 Meter Abstand von diesen Bereichen Halten Sie bei der Installation des Rauchwarnmelders in der N he von Be und Entl ftungssch chten oder ffnungen f r W rme und K lteversorgung mindestens 1 Meter Abstand zu diesen Bereichen Die Luft k nnte den Rauch vom Rauchwarnmelder wegblasen und somit den Alarm unterbrechen oder verhindern Bringen Sie keine Rauchwarnmelder in Garagen an die beim Starten eines Kraftfahrzeugs entstehen den Verbrennungsr ckst nde Abgase k nnen Fehlalarme ausl sen Bei Spitzd chern mit einer Dachneigung gt 20 ist der Rauchwarnmelder in einer Entfernung von mind 50 cm und max 1 50 m von der Giebelspitze anzubringen siehe Bild 1 Dachneigungen lt 20 sind wie horizontale Decken zu behandeln Ungeeignet sind R ume in denen die Temperaturen unter 0 C fallen oder ber 40 C steigen oder in denen die Luftfeuchtigkeit mehr als 93 betr gt Befestigen Sie den Rauchwarnmelder z B nicht an der Decke eines Wohnwagens oder hnlichen R umen Sonnenstrahlen erw rmen hier die Luft schnell so dass m glicher Rauch dadurch abge
11. eight exceeds 6 m install additional smoke alarm devices at different height levels ceiling 50 cm min Heat a w and K Dead space 7 en smoke Do not mount 5 from herel g fire ig alternative gt ideal position position x x 50 cm OS cm a Living room Bedroom Smoke alarm for minimum protection Smoke alarm for optimum protection ci Installation sites with restrictions A a LED TEST button x z For a minimum level of safety it is recommended to install one smoke alarm for each hall and stairway on each floor as well as in each bedroom and children s room see Figure 2 and 3 For achieving an optimal level of safety install one smoke alarm in each room hall cellar room and attic room etc please observe 4 2 Installation Locations with Restrictions In buildings with multiple living quarters the installation of smoke alarms should be conducted separately in each living quarter as well as in all common halls and stairways e In stairways install the smoke alarm at the top of the stairs as a chimney effect often occurs rapidly drawing smoke into the upper floors For installation make sure that the smoke alarm is mounted at least 50 cm away from each side wall or any large piece of furniture e g high cupboards see Figure 1 The specified installation locations as well as the depicted positio
12. halten wird an den Rauchwarnmelder zu gelangen und Alarm auszul sen In sehr schmutzigen staubigen schmierigen oder von Insekten befallenen Bereichen k nnen Rauch warnmelder berm ig durch Staub und Schmutz verunreinigt werden sodass es zu Fehlalarmen oder Beeintr chtigungen bei der Raucherkennung kommen kann Das Alarmsignal des Rauchwarnmelders ist i d R laut genug um Personen zu warnen Allerdings kann es zu Situationen kommen in denen Personen das Alarmsignal nicht h ren k nnen z B hohe L rmkulisse Personen mit einem sehr tiefen Schlaf und oder einer H rbehinderung Personen unter Drogen oder Alkoholeinfluss etc Wenn Sie vermuten dass dies auf Personen Ihres Umfelds zutrifft installieren Sie zus tzlich spezielle Rauchwarnmelder 4 3 Montage der Grundplatte Halten Sie die Grundplatte des Rauchwarnmelders an die Montagestelle die beiden Befestigungsl cher dienen als Schablone zum Anzeichnen der Bohrl cher Vergewissern Sie sich vor der Bohrung und Montage dass sich im Bereich der Montagestelle keine elektrischen Leitungen Wasser Gas oder sonstige Leitungen befinden An einer Holzdecke oder Balken bohren Sie mit einem 2 5 mm Bohrer ca 20 mm tief Verwenden Sie die beiliegenden Schrauben ohne D bel Bei Beton oder Mauerwerk benutzen Sie max einen 5 mm Bohrer beiliegende D bel vorher ausmes sen und bohren Sie ca 25 30 mm tief vor um die D bel einsetzen zu k nnen Setzen Sie die D
13. ible The alarm sound is very loud Do not test the smoke alarm close o the ear Sound pressure level in alarm mode min 85dB Do not modify the product in any way Failure to observe will result in the loss of any warranty Carbon monoxide flames heat gases etc cannot be detected by the smoke alarm The installation of smoke alarms neither prevents fires nor does it facilitate extinguishing of fires Smoke alarms are not warranted to protect lives and property Smoke alarms are not a substitute for insurance The battery is permanently integrated and cannot be removed Dispose of the product as a whole in compliance with the legal regulations The smoke alarm does not contain any radioactive substances oe ce ew 4 Installation 4 1 Recommended Installation Locations In each apartment place smoke alarms at least in every bedroom and nursery as well as in the hallways leading to these rooms and along escape routes If the total length of the hall is more than 10 m install one smoke alarm on each end of the hallway Smoke and combustion by products rise upward towards the ceiling before spreading horizontally The ideal installation location is on the ceiling in the middle of the room A single smoke alarm device is only permitted for rooms of up to 60 m If the room is larger than 60 m use additional smoke alarms A single smoke alarm is only permitted for a maximum installation height of 6 m If the room h
14. ie Betriebsdauer der 3V Lithiumbatterie in diesem Rauchwarnmelder betr gt zehn Jahre Bei schwacher Batterie ert nt alle 40 Sekunden ein Signalton Die LED blinkt weiterhin alle 40 Sekunden auf Der Hinweis auf eine schwache Batterie erfolgt mindestens ber einen Zeitraum von 30 Tagen Ersetzen Sie den Rauchwarnmelder in diesem Zeitraum durch ein neues Ger t Signalisiert der Rauchwarnmelder eine schwache Batterie k nnen Sie durch Druck auf die TEST Taste den Signalton f r 10 Stunden unterbrechen In dieser Zeit kann der Rauchwarnmelder normalerweise im mer noch Rauch erfassen Bem hen Sie sich um einen unverz glichen Austausch durch ein neues Ger t Neben der Lebensdauer der Batterie ist auch die Lebensdauer des Rauchwarnmelders insbesondere des Sensors zeitlich begrenzt Beachten Sie daher vor Montage des Rauchwarnmelders das darauf aufgedruckte Date of Replacement Wechseln Sie den Rauchwarnmelder zu diesem empfohlenen Datum durch ein neues Ger t aus auch wenn noch kein Hinweis auf eine schwache Batterie erfolgt 7 4 Pflege Reinigen Sie den Rauchwarnmelder regelm ig mind einmal monatlich um Staub Schmutz und Ablagerungen zu entfernen Verwenden Sie einen Staubsauger mit einer weichen B rste und saugen Sie vorsichtig alle Seiten und Abdeckungen des Rauchwarnmelders ab Demontieren Sie den Rauchwarnmelder oder decken Sie ihn staubfrei ab bevor Sie mit Renovie rungsarbeiten beginnen Verwahren Sie ihn idealerweise w h
15. ke alarm is ten years The smoke alarm indicates a weak battery by emitting an audible signal tone and the LED flashes repeatedly every 40 seconds Weak battery indication is given for a period of at least 30 days Please replace the smoke alarm within this period with a new device When the smoke alarm is indicating a weak battery the signal tone can be interrupted for 10 hours by pressing the TEST button During this period the smoke alarm is generally still capable of detecting smoke However take care to immediately replace it with a new device Both the battery service life and the service life of the smoke alarm itself in particular of the sensor are limited in time For this reason observe the Date of Replacement printed on the device prior to mounting the smoke alarm Replace the smoke alarm at the recommended date with a new device even if a discharged battery is not indicated 7 4 Care Regularly clean the smoke alarm at least once per month to free the device from dust dirt and residues Use a vacuum cleaner with a soft brush and carefully vacuum the smoke alarm from all sides and on all covers Dismount the smoke alarm or cover it to keep it dust free prior to starting the renovation works Ideally store the device in a safe and dust free location during the period of the renovation Make sure that no paint is applied to the smoke alarm and that no residue of masking tape is left on the enclosure Dust paint ta
16. ns of the smoke alarms are only of exemplary nature on the basis of average homes and houses and do only serve as a point of reference Mounting the smoke alarm should be conducted by a qualified and certified electrician Observe all local and national electrical and building codes for installation 4 2 Installation Locations with Restrictions e Smoke alarms should only be installed in kitchens and damp rooms bathrooms if the restrictions from Figure 1 are observed and false alarms caused by kitchen vapours or water steam can be ruled out For installing the smoke alarm near dishwashers washing machines ovens etc observe a minimum installation distance of 3 metres away from these appliances For installing the smoke alarm near ventilation shafts or openings for heat and cold air supply observe a minimum installation distance of 1 metre away from such areas The air stream could blow the smoke away from the smoke alarm and therefore interrupt the alarm or prevent the alarm from being triggered Do not install smoke alarms in garages the combustion by products exhaust fumes caused by starting a car can trigger false alarms For peaked roofs with an angle gt 20 the smoke alarm should be installed at a distance of at least 50 cm and no more than 1 m away from the gable peak see Figure 1 Roofs with angles of lt 20 can be handled the same as horizontal ceilings Rooms in which either temperatures fall below 0 C or rise abov
17. ntsprechenden Versicherungen umgangen Die Batterie ist fest eingebaut und kann nicht entfernt werden Entsorgen Sie das Produkt als Ganzes gem den gesetzlichen Bestimmungen e Der Rauchwarnmelder enth lt kein radioaktives Material 4 Montage 4 1 Empfohlene Montageorte Platzieren Sie Rauchwarnmelder pro Wohnung mindestens in jedem Schlaf und Kinderzimmer sowie in den Fluren die zu diesen R umen f hren und auf Rettungswegen e Wenn die L nge eines Flurs mehr als 10 m betr gt montieren Sie einen Rauchwarnmelder an jedem Ende e Rauch und Verbrennungsr ckst nde steigen nach oben an die Zimmerdecke und verbreiten sich dann erst horizontal Der ideale Montageort ist an der Decke in der Mitte des Zimmers Ein Rauchwarnmelder ist nur f r Raumgr en bis max 60 m zugelassen bersteigt die Raumgr e 60 m verwenden Sie zus tzliche Rauchwarnmelder Ein Rauchwarnmelder ist nur f r Einbauh hen bis max 6 m zugelassen bersteigt die Raumh he 6m sind zus tzliche Rauchwarnmelder in mehreren Ebenen anzubringen Decke 50 cm min Hitze gt und _ Toter Raum 7 u Rauch Niemals hier 3 vom gt S Feuer gt alternative gt ideale Position Position 50 cm Wohnzimmer Schlafzimmer Rauchwarnmelder f r Mindest Schutz Rauchwarnmelder f r optimalen Schutz ge Montageorte mit Einschr nkungen ww a N O scat Flur R zimmer zimmer
18. pe and other dirt can impair the sensitivity of the alarm trigger and can potentially render the smoke alarm inoperative and without function Remount all correctly functioning smoke alarms back on their installation location and immediately replace smoke alarms without correct function by new devices Check all smoke alarms for correct function after mounting as described under 7 1 Test 8 Warranty Disclaimer Hama GmbH amp Co KG assumes no liability and provides no warranty for damage resulting from improper installation mounting improper use of the product or from failure to observe the operating instructions and or safety notes 9 Service and Support Please contact Hama Product Consulting if you have any questions about this product Hotline 49 9091 502 115 German English Further support information can be found here www hama com 13 Recycling Information Note on environmental protection After the implementation of the European Directive 2002 96 EU and 2006 66 EU in the national et legal system the following applies Electric and electronic devices as well as batteries must not be disposed of with household waste Consumers are obliged by law to return electrical and mmm electronic devices as well as batteries at the end of their service lives to the public collecting points set up for this purpose or point of sale Details to this are defined by the national law of the respective country This symbol on the product
19. rend der Dauer der Arbeiten an einem sicheren und staubfreien Ort Achten Sie darauf dass keine Farbe auf den Rauchwarnmelder aufgetragen wird oder Reste von Klebeband auf dem Geh use zur ckbleiben Staub Farbe Klebeband oder sonstige Verschmutzungen k nnen die Zuverl ssigkeit der Ausl sung beein tr chtigen und m glicherweise den Rauchwarnmelder vollst ndig funktions und wirkungslos machen Montieren Sie alle korrekt funktionierenden Rauchwarnmelder wieder an ihren Montageorten und ersetzen Sie nicht mehr korrekt funktionierende Rauchwarnmelder sofort durch neue Ger te Pr fen Sie alle Rauchwarnmelder nach der Montage auf ihre Funktion wie unter 7 1 Test beschrieben 8 Haftungsausschluss Die Hama GmbH amp Co KG bernimmt keinerlei Haftung oder Gew hrleistung f r Sch den die aus unsachgem er Installation Montage und unsachgem em Gebrauch des Produktes oder einer Nicht beachtung der Bedienungsanleitung und oder der Sicherheitshinweise resultieren 9 Service und Support Bitte wenden Sie sich bei Fragen zum Produkt gerne an die Hama Produktberatung Hotline 49 9091 502 115 Deu Eng Weitere Supportinformationen finden Sie hier www hama com 10 Entsorgungshinweise Hinweis zum Umweltschutz Ab dem Zeitpunkt der Umsetzung der europ ischen Richtlinien 2002 96 EG und 2006 66 EG in nationales Recht gilt folgendes Elektrische und elektronische Ger te sowie Batterien d rfen nicht mit dem Hausm ll entsorg
20. t immer Ihre sofortige Aufmerksamkeit und die Ergreifung von entsprechenden Ma nahmen a 6 3 Verhalten im Alarmfall Empfehlung Retten Sie sich und andere Bewahren Sie Ruhe e Warnen Sie andere Familienmitglieder und oder Mitbewohner Verlassen Sie nun sofort das Haus und schlie en Sie alle T ren und Fenster Ihrer Fluchtroute wenn dies gefahrlos m glich ist um die Ausbreitung von Rauch und Brand zu verlangsamen e Gehen Sie nach Verlassen des Hauses zu Ihrem vereinbarten Sammelplatz und stellen Sie sicher dass alle Personen das Haus verlassen haben Feuerwehr rufen Rufen Sie die Feuerwehr sobald Sie sich in Sicherheit befinden L schversuche e Starten Sie eigene L schversuche nur wenn Sie dabei nicht sich selbst oder andere in Gefahr bringen und Sie ber geeignete L schmittel verf gen 6 4 Stummschaltmodus bei Fehlalarm Bevor Sie den Stummschaltmodus aktivieren kl ren Sie die Ursache f r den Alarm und vergewissern Sie sich dass keine weitere Gefahr besteht Zigarettenrauch wird normalerweise den Alarm nicht ausl sen au er der Rauch wird direkt in den Rauchwarnmelder geblasen Wasserdampf der beim Kochen entsteht kann einen Alarm ausl sen wenn sich der Rauchwarnmelder in der N he von Kochstellen befindet Sollte ein Alarm ausgel st werden pr fen Sie ob es sich tats chlich um einen Ernstfall handelt Ist Feuer oder Rauch vorhanden rufen Sie die Feuerwehr bzw verhalten
21. t werden Der Verbraucher ist gesetzlich verpflichtet elektrische und elektronische Ger te sowie Batterien am Ende ihrer Lebensdauer an den daf r eingerichteten ffentlichen Sammelstellen oder an die Verkaufsstelle zur ckzugeben Einzelheiten dazu regelt das jeweilige Landesrecht Das Symbol auf dem Produkt der Gebrauchsanleitung oder der Verpackung weist auf diese Bestimmungen hin Mit der Wiederverwertung der stofflichen Verwertung oder anderen Formen der Verwertung von Altger ten Batterien leisten Sie einen wichtigen Beitrag zum Schutz unserer Umwelt 11 Hersteller und Genehmigungsinhaber Ningbo Siterwell Electronics Co Ltd No 76 Haichuan Road Chuangye Zone B Jiangbei Ningbo China 1 Distributed by Hama GmbH amp Co KG 86652 Monheim Germany www hama com C 0786 CPR 21388 p u G 214063 All listed brands are trademarks of the corresponding companies Errors and omissions excepted and subject to technical changes Our general terms of delivery and payment are applied 00108875 10 15
22. the manner described in 6 3 Behaviour in the Event of Alarm Recommendation e Upon ensuring that a false alarm was triggered press the TEST button of the smoke alarm to activate the alarm silencing mode and mute the alarm signal for approx 10 minutes e The red LED will then flash every 8 seconds to indicate that the smoke alarm is in the alarm silencing mode e The smoke alarm is reset automatically after approx 10 minutes If smoke particles are still present after this time the alarm signal is triggered again e The alarm silencing mode can be activated repeatedly 7 Care and Maintenance 7 1 Test Press the TEST button on the smoke alarm The alarm signal sounds if the electronics the sensor the horn and the battery are all functioning correctly Immediately replace smoke alarms without correct function by new devices It is recommended to test the smoke alarm on a weekly basis in order to ensure its correct function Only test the smoke alarm by using the TEST button Never use an open flame a lighter etc to simulate an alarm and to test the functionality 7 2 Alarm Simulation Press and hold the TEST button on the smoke alarm to simulate an alarm situation Like in a genuine alarm event the LED keeps flashing once per second and an audible alarm signal sounds as long as the TEST button is pressed 7 3 Battery Replacing the Smoke Alarm The battery service life of the 3V lithium battery in this smo
23. uccessful alarm signal is generated repeat the activation steps described in 5 1 Activation Operation 1 Emergency escape plan Recommendation Discuss and create an emergency escape plan together with your family and or cohabitants f possible also take alternative escape routes into account as fire could block the standard routes Demonstrate the alarm signal of the smoke alarm to your family and or cohabitants see 7 2 Alarm Sim ulation and make sure that each person is informed about adequate behaviour in the event of an alarm Make sure that also your children are able to recognize an alarm case and that they can see them selves to safety Determine a location outside of your house as a meeting point in the event of an alarm f necessary practise the appropriate behaviour during alarm at regular intervals Practising helps your amily and or cohabitants to quickly leave the house in an orderly fashion in the event of an alarm 2 Alarm Event n the event of an alarm as soon as the smoke alarm detects combustion particles or when perform ing an alarm simulation see 7 2 Alarm Simulation the LED keeps flashing once per second and an audible alarm signal sounds Alarm signal sound sequence 3x signal tone short pause 3x signal tone short pause 3x signal one short pause The alarm signal sound will persist until the smoke alarm is no longer able to detect any combustion particles in the air the alarm silencing
24. zlich Informationen oder wichtige Hinweise zu kennzeichnen 2 Packungsinhalt photoelektronischer Rauchwarnmelder mit VdS Pr fzeichen Grundplatte e Montagematerial Batterie 3V Typ CR123A Lithium fest eingebaut diese Bedienungsanleitung 3 Sicherheitshinweise Betreiben Sie das Produkt nicht in unmittelbarer N he der Heizung anderer Hitzequellen oder in direkter Sonneneinstrahlung Lassen Sie das Produkt nicht fallen und setzen Sie es keinen heftigen Ersch tterungen aus ffnen Sie das Produkt nicht und betreiben Sie es bei Besch digungen nicht weiter Beachten Sie f r eine korrekte Funktion die in dieser Bedienungsanleitung angegebenen Montage und Installationshinweise e Bei jeglicher Art von Besch digung ist der Rauchwarnmelder auszutauschen Erstellen Sie f r den Notfall einen Fluchtplan Hinweise dazu finden Sie unter 6 1 Der Fluchtplan Empfehlung e Warnung vor H rsch den Der Rauchwarnmelder ist sehr laut Rauchwarnmelder nicht direkt neben dem Ohr testen Schallpegel Alarmsignal min 85 dB e Nehmen Sie keine Ver nderungen am Produkt vor Dadurch verlieren Sie jegliche Gew hrleistungs anspr che Kohlenstoffmonoxid Flammen Hitze Gase etc k nnen nicht vom Rauchwarnmelder erkannt werden Die Installation von Rauchwarnmeldern verhindert weder Brande noch k nnen diese dadurch gel scht werden Ebenso wird kein Schutz von Leben und Besitz gew hrleistet sowie die Notwendigkeit von e
Download Pdf Manuals
Related Search
Related Contents
3P Technik 1000500 Installation Guide Toshiba Portégé Z935-ST4N04 Acer AL1917X User's Manual Effective Ways of Validating SAS Programs www.cbradio.nl: Manual Midland Massive Kico Suspension light 40092/34/10 Stowe 8322 DX Manual User Manual - 10 Bar Underwater Housings Sony XM-SD51X Operating Instructions Copyright © All rights reserved.