Home
Manual 1.0 Icon Series™ LTS System
Contents
1. 5 E 5 60 rer 6 Fig 4 Signal routing diagram for an ICON LTS stach NEEN 6 Fig 5 Signal routing diagram for a twin ICON LTS ENNEN 6 Fig 6 Tilt angle for two ICON stack EEN 6 Fig 7 ICON IC 112 LA with Aeroquip rails 7 Fig 8 How to mount and adjust the ICON Tilt Unit 7 Fig 9 The ICON mid high unit s control features 7 Fig 10 The ICON IC 118 BA s control features 8 Fig 11 How to set up the system and route signals sss 9 Fig 12 The PodWare s basic functions 10 Fig 13 The EQ Delay device 10 Fig 14 Device Panel Properties Options 11 UNIQUE FEATURES FOR PREMIUM PERFORMANCE Next generation digital amping for even greater efficiency and better dynamic response With an efficiency rating topping the 90 mark Class D digital power amps are substantially smaller lighter and more compact than conventional amps The reduced thermal load on components enhances reliability while the far faster slew rate and higher attenuation factor audibly enhances the speed and precision of the system s dynamic response PodWare BVNet for operating and controlling ICON components remotely ICON LTS user mode lets you control it remotely via a BVNet interface and a laptop Courtesy of PodWare the included PC software application and the BVNet interface that connects
2. Die Software wird gestartet nd Hinweise zur Benutzung von PodWare finden Sie unter dem Men Help Helptopics in Form eines HTML Kataloges Installation des BVNet Modul Interface Informationen zur Installation des BVNet Modul Interface entnehmen Sie bitte der technischen Anleitung User Guide die beim BVNet Modul beiliegt 4 4 BEDIENUNG DER SOFTWARE Nach der Installation k nnen Sie die PodWare mit einem Doppelklick ffnen e Verbinden Sie nun das ICON System mit dem BVNet Interface und schlie en dann den Laptop an Abbildung 13 Device Panel EQ Delay 1 Equalizer mit 8 vollparametrischen B ndern Einstellbare Parameter Freq 10 Hz bis 25 6 kHz G te Q Faktor 0 17 bis 14 2 bzw Oktaven 0 102 bis 5 25 Gain 15 dB bis 15 dB Die Bedienung des EQ erfolgt mit der Maus oder per File Preferences Network Device Panel Help Direkteingabe der Werte Ein direktes Linken der Ger te ist nicht m glich aller dings ein Kopieren von EQ Einstellungen mit Copy and Paste 2 Low Shelf High Shelf Filter Einstellbare Parameter Freq 10 Hz bis 25 6 kHz Slope 6dB bis 12dB Gain 15 dB bis 415 dB Die bernahme der Werte der einzelnen Ger te ist hier nur via Copy and Paste m glich Abbildung 12 Grundfunktionen der PodWare 3 Low Pass High Pass Filter Einstellbare Parameter Freq 20 2 Hz bis 25 6 kHz Filtertyp 1 Ordnung Bessel Butterworth Linkwitz Riley Bessel je 1 Ne
3. Die Standardeinstellung f r ICON Systeme betr gt 4 dBu Stellen Sie sicher dass das System vor dem Einschalten mit den Subwoofern verkabelt ist ber Sub Out und dass alle brigen angeschlossenen Komponenten schon vorher in Betrieb sind Sowohl das angeschlossene Mischpult als auch alle mit ihm verbundenen Signalquellen wie Keyboards Instrumentalverst rker Effekte usw sollten eingeschaltet sein Falls Verzerrungen oder bersteuerungen auftreten berpr fen Sie die Signalquellen und reduzieren Sie nach M glichkeit dort das Ausgangssignal L sst sich das zum ICON LTS f hrende Signal auf diese Weise nicht ver ndern passen Sie es mit den Gain Reglern an siehe auch Tipps und Tricks SIGNALANSCHL SSE IC 112 LA e Input Schlie en Sie die von Ihrem Mischpult kommenden Signalkabel Master left right Line out o an die symmetrierten Eingangs Buchsen mit einem XLR Mikrofonkabel an Die Belegung der XLR Stecker muss dabei wie folgt sein 12 Ground 2 3 E ICON SERIES IC 112 LA Made in Germany Abbildung 9 ICON Mid High Bedienelemente 17 ICON SERIES LTS 1 0 e Through Paralleler Ausgang zur Weiterleitung des Eingangs Line Signals e Sub Output Ausgang des Subwoofer Signals von der IC 112 LA Mid High Unit an den ICON IC 118 BA Sub mittels XLR Kabel Die Belegung der XLR Stecker muss dabei wie folgt sein 12 Ground 2 3 e BVNet In Link Verbinden Sie den Ausga
4. Grille Roulettes Accessoires Dimensions x H x P Poids ICON IC 118 BA Connexions Imp dance d entr e Sensibilit d entr e Niveau d entr e maxi R ponse en fr quence 3dB R ponse en fr quence 10 dB Sensibilit 1W 1m SPL calcul maximum SPL de cr te SPL max Ampli subwoofer Circuits de protection actifs Haut parleur de basses Embase pour pied Poign es Grille Roulettes Accessoires Dimensions x H x Poids 1 Dimensions en Half Space 1x XLR Line In 1x XLR Line Through 1x XLR Sub Out 2x BVNet RJ 45 IN OUT 1x Ethernet RJ45 Internal System Guard 20 kohms 10 dBu o dBu 4 dBu 16 dBu s lectionnable 22 dBu 134 Hz 17 kHz filtre du syst me LTS 108 Hz 17 kHz 109 dB 120 Hz 16 kHz 139 dB bas sur la capacit de charge de cr te 136 dB SPL 1096 THD 131 dB SPL 1096 THD 120 Hz 12 kHz 134 dB SPL 1096 THD 120 Hz 5 kHz 1x 1000 W Class D Ohm 1x 600 W Class D 4 Ohm Limiteur RMS limiteur de cr te filtre Subsonic 12 Neodym 1 4 60 x 40 pavillon CD 900 Hz 24 dB octave Aeroquip 4 poign es noy es Grille m tallique noire avec mousse d isolation acoustique Planche roulettes avec roulettes orientables 4 x 100mm Unit d inclinaison ICON 5 10 15 Housse de protection 50 x 81 cm 15 3 4 x 26 x 19 3 4 49 9 kg 110 lbs sans planche roulettes
5. Evitate un allacciamento alla rete di corrente utilizzando cassette di distribu zione sovraccariche La spina di corrente deve essere situata nelle vicinanze dell apparecchio e facilmente raggiungibile in qualsiasi momento LOCALI DI COLLOCAMENTO Opportuno collocare l apparecchio su una superficie pulita e orizzontale Non sottoporre l apparecchio in funzione a scosse e vibrazioni l apparecchio deve essere posizionato sempre in modo da assicurare il libero accesso all interruttore di alimentazione Proteggere l apparecchio per quanto possibile da umidit e polvere Non collocare l apparecchio vicino ad acqua vasche da bagno lavandini lavelli da cucina locali umidi o piscine Non appoggiare recipienti contenenti liquidi vasi bicchieri bottiglie ecc sull apparecchio Provvedere ad una buone aerazione dell apparecchio Eventuali aperture previste per la ventilazione dell apparecchio non vanno ne bloccate ne mai coperte L apparecchio va collocato ad almeno 20 cm di distanza dalle pareti circostanti e pud essere inserito tra altre componenti di un impianto solo in caso di sufficiente ventilazione e qualora le direttive di montaggio del produttore vengano rispettate Evitare di esporre l apparecchio ai raggi del sole e di collocarlo direttamente nelle vicinanze di fonti di calore come caloriferi stufette ecc Se l apparecchio viene trasportato rapidamente da un locale freddo ad uno riscaldato pu succedere che al suo
6. 1 Net Scan PodWare parcourt l int gralit du r seau la recherche de p riph riques connect s 2 Locating Il est possible de piloter une DEL Wink l aide du module DSP Si l utilisateur a raccord plusieurs p riph riques sur le PodWare et qu il ouvre leur panneau de commande un bref clignotement de cette DEL l activation de l ic ne indiquera quel haut parleur p riph rique DSP se rapporte ce panneau Cette fonction sert donc l identification des p riph riques modules DSP dans l unit Mid High 3 Mute Fait passer simultan ment l tat Mute tous les p riph riques connect s au r seau 4 Launch all Panels Cette fonction permet d ouvrir simultan ment tous les panneaux de commande de tous les appareils raccord s au r seau Chaque haut parleur branch sur le module DSP s affiche comme Device Panel dans le PodWare Les param tres et fonctions de surveillance peuvent tre lus modifi s et contr l s sur deux niveaux de fen tres DEVICE PANEL EQ DELAY FR Kunde PA algix Foods Meet Desc Heb 21 ICO 1 as 2 Fig 13 Device Panel Delay 1 galiseur 8 bandes enti rement param trique Param tres r glables fr q 10 Hz 25 6 KHz qualit facteur gt 0 17 14 2 octaves gt 0 102 5 25 Gain 15 dB 15 dB La commande de l EQ galisation s effectue l aide de la souris ou
7. den Zustand der Lautsprecher werden f r 72 Betriebsstunden gespeichert und k nnen ausgelesen werden um die Einstellungen der letzten Veranstaltungen nachvollziehen zu k nnen lt a IC 112 LA BVNet RS485 RJ45 Cable In Interface IC 118 BA USB Cable IC 118 BA E Laptop Abbildung 11 Systemaufbau Verkabelungsskizze Die Anbindung der Lautsprecher an einen PC Laptop erfolgt ber ein zweiadriges CAT5 Kabel mit handels blichen RJ45 Steckverbindern Die RS485 Schnittstelle arbeitet auf einem gemeinsamen Bus so k nnen mit nur einem Computer alle Einheiten im System gesteuert und der Betriebszustand berwacht werden Daisy chain Jedes DSP Modul besitzt eine eigene unverwechselbare Adresse dadurch er brigt sich die Konfiguration der Netzwerk Knoten durch den Nutzer Jeder Lautsprecher berwacht seine eigenen digitalen Signalbearbeitungsfunktionen damit bleibt ein eventueller Ausfall auf diesen einen Knotenpunkt beschr nkt Da ausschlie lich Einstellungs und momentane Systemdiagnose Daten im Netzwerk bertragen werden wird die Audiowiedergabe nicht unterbrochen Zur Daten bertragung wird ein CAT5 Kabel verwendet dieses Twisted Pair gew hrleistet die Verbindung zu einer Vielzahl m glicher Einheiten auch ber gro e Distanzen CATs ist wegen seiner Rausch Immunit t und gro er Verbindungsl ngen einer der meistverwendeten Standards in der Kommunikationstechnologie Das Sy
8. 1 Messungen in Half Space 1x XLR Line In 1x XLR Line Through 1x XLR Sub Out 2x BVNet RJ45 IN OUT 1x Ethernet RJ45 Internal System Guard 20 kOhm 16 dBu 4 dBu o dBu 10 dBu w hlbar 22 dBu 134 Hz 17 kHz LTS System Filter 108 Hz 17 kHz 109 dB 120 Hz 16 kHz 139 dB basierend auf Peal Belastbarkeit 136 dB SPL 1096 THD 131 dB SPL 1096 THD 120 Hz 12 kHz 134 dB SPL 1096 THD 120 Hz 5 kHz 1x 1000 W Class D Ohm 1x W Class D 4 Ohm RMS Limiter Peak Limiter Subsonic Filter 12 Neodym 1 4 60 x 40 CD Horn 900 Hz 24 dB Oktave Aeroquip 4x versenkte Schalengriffe Schwarzes Metallgitter mit Akustikschaum Rollbrett mit 4x 100 mm Lenkrollen ICON Tilt Unit 5 10 15 Schutzh lle 50x 60 x 81 cm 19 11 16 x 23 5 8 x 31 7 8 49 9 kg 110 lbs ohne Rollbrett 1x XLR Input 1x XLR Through 2x Ethernet RJ45 Internal System Guard 20 kOhm 4 dBu 22 dBu 41 Hz fx 33 Hz fx 105 dB 138 dB basierend auf Peak Belastbarkeit 138 dB SPL 1096 THD 90 Hz 100 Hz 136 dB SPL 1096 THD 1x 2000 W Class D 0 4 Ohm Subsonic Filter System Controller with Peak Limiter 18 Neodym 2x M20 Gewindeplatte 8x versenkte Schalengriffe Schwarzes Metallgitter mit Akustikschaum Rollbrett mit 4x 100 mm Lenkrollen Schutzh lle 50 X 90 x 81 cm 20 1 2 x 28 1 2 x 28 1 8 54 1 119 2 lbs ohne Rollbrett ALLGEMEINE TECHNISCHE DATEN Maximale Leistungsaufnahme Maximale Stroma
9. Follow the same procedure to connect further components equipped with DSP modules e Sub Link In Port Internal System Guard You can monitor the entire system s performance if you connect the IC 118 BA subwoofer to the mid high unit via the Internal Link ports using a standard Ethernet cable RJ45 e PowerCon Mains Input Twisting the PowerCon connector until locks switches on the speaker cabinet Use the factory included PowerCon mains cord to connect this socket to a wall receptacle Caution Make sure the local mains voltage matches the voltage specified on the device Connecting the system to the wrong mains voltage may destroy the ICON system s electronic components Heads up Current consumption may not exceed 16 amps per phase which comes to 3 600 watts at 230 volts This means each phase can power no more than one ICON LTS stack comprising one mid high unit and two subwoofers These values may vary depending on the country voltage and venue Be sure to check how much power the mains supply provides in watts or amperes before you switch the system on Always switch ICON components on one after another rather than all at once to keep inrush currents as low as possible High inrush current can trip the venue s mains fuse THE IC 112 LA s LED INDICATORS e Limit LED This LED indicates the Class D power amps peak limiter has engaged to attenuate a maximum output voltage excursion or put simply a clipping signal e
10. Transfert du signal de subwoofer depuis l unit Mid High IC 112 LA vers l ICON IC 118 BA Sub au moyen d un c ble XLR Les broches des prises XLR doivent tre affect es comme suit 1 terre 2 3 e BVNet In Link Reliez la sortie de l interface BVNet la douille In de la premi re unit Mid High Reliez pr sent la douille In l unit Mid High suivante via la douille Link Pour raccorder d autres composants au module DSP proc dez de la m me facon e Douille Sub link In Internal System Guard En raccordant les subwoofers IC 118 BA l unit Mid High via les douilles Internal Link vous pouvez surveiller le fonctionnement de l ensemble du syst me Pour ce faire branchez les subwoofers l unit Mid High via un c ble Ethernet standard RJ45 Mains Input Powercon En tournant le connecteur Powercon jusqu la but e le connecteur s encliquette vous activez le haut parleur Branchez sur cette fiche secteur la prise correspondante du cordon secteur Powercon fourni Attention Veillez v rifier la tension disponible localement En effet le raccordement une tension secteur incorrecte est susceptible de d truire l lectronique du syst me ICON Attention Une phase peut supporter au maximum une intensit de 16 A ou une puissance de 3600 W pour 230 V Vous pouvez donc y brancher au maximum un stack ICON LTS 1x unit Mid High 2x subwoofer Ces valeurs peuvent varier suivant le pay
11. durant les 72 derni res heures de fonctionnement diagnostic de performance puissance surveillance des moteurs et fonctions de protection de l tage de puissance 1 COMPOSANTS DU SYST ME ICON 1 1 UNIT MID HIGH CHARGE MENT PAR PAVILLON IC 112 LA 172 LA Fig 1 IC 112 LA Equip e d un haut parleur 12 HK AUDIO Custom et d un moteur de compression 1 4 pavillon CD 60 x 40 l unit Mid High IC 112 LA offre une r solution impressionnante et une directivit exem plaire l unit Mid High comporte aussi la centrale de connexion num rique du syst me concern le module DSP Depuis celui ci le signal est ache min via un diviseur de fr quence deux canaux vers les deux tages de puissance de Classe D qui fournissent une puissance de 1x 300 watts sous 8 ohms pour le moteur d aigus et de 1x 500 watts sous 8 ohms pour le haut parleur 12 chargement par pavillon L ensemble de l lectronique est log dans un compartiment sp cifique situ l arri re de l enceinte et peut tre command via le panneau de commande Ce compartiment abrite aussi les connexions et les DEL qui indiquent le mode de fonctionnement du syst me 1 2 SUBWOOFER FILTRE PASSE BANDE IC 118 BA DR Gees Fig 2 IC 118 BA Le subwoofer IC 118 BA est log dans une enceinte filtre passe bande La partie sup rieure constitue la v ritable enceinte du haut parleur de 18 l arri
12. re de celle ci et compl tement s par e on trouve le bo tier abritant l tage de puissance Tous les param tres servant la commande du subwoofer sont transmis au subwoofer via la prise Sub Out de l unit Mid High Remarque importante L IC 118 BA est un subwoo fer syst me concu pour l interaction avec l unit Mid High IC 112 LA II ne comporte pas de diviseur de fr quence propre et fonctionne hors du syst me ICON sans s paration de fr quence ni limitation Evitez donc imp rativement de le raccorder un si gnal audio sans contr leur en amont int gr dans l unit Mid High IC 112 LA 1 3 TRANSPORT Une planche roulettes est pr vue pour simplifier le transport du syst me Employez les housses HK AUDIO ICON d origine afin de prot ger votre syst me contre la rudesse des d placements en tourn e Correctement amorti et prot g contre l humidit votre syst me ICON vous procurera enti re satisfaction pendant longtemps 25 ICON SERIES LTS 1 0 2 INSTALLATION ET C BLAGE 2 1 SYST ME ICON LTS Le syst me standard System ICON LTS se compose de deux IC 112 LA et de quatre IC 118 BA Fig 3 Systeme ICON LTS Le syst me ICON est toujours c bl de haut en bas voir Fig 4 Le syst me ICON LTS abrite le contr leur syst me central pour le stack complet dans l unit Mid High IC 112 LA Le signal de graves filtr pour le sub woofer et le signal de commande pour l utilisat
13. Fa STAMER Musikanlagen GmbH durchgef hrt wurden Zur Beurteilung des Erzeugnisses hinsichtlich elektromagnetischer Vertr glichkeit wurden folgende Normen herangezogen EN61000 6 1 EN61000 6 2 Zur Beurteilung der Einhaltung der Niederspan nungsrichtlinie wurde folgende Norm herange zogen EN 60065 Diese Erkl rung wird verantwortlich f r den Hersteller SIAM STAMER MUSIKANLAGEN GMBH Magdeburger Str 8 66606 St Wendel abgegeben durch Kone Lothar Stamer Dipl Ing Gesch ftsf hrer St Wendel den 29 06 2009 Version 2 0 08 2008 33 ICON IC 112 LA ICON IC 118 BA 24 21 12 9 3 0 21 18 W 9 5 Mo 3 18 15 15 12 O 24 21 21 18 18 15 1 15 12 2 5 2 lt LL Max SPL Deg 150 100 50 Directivity horizontal 2D 50 100 150 Grooup Delay Grooup Delay 9840200 D 2241 HK Audio Postfach 1509 66595 St Wendel Germany info hkaudio com www hkaudio com International Inquiries fax 49 68 51 905 215 International hkaudio Technische nderungen vorbehalten Copyright 2009 Music amp Sales GmbH 07 2009
14. XLR Stecker muss dabei wie folgt sein 1 Ground 2 3 Abbildung 5 siehe unten Aufstellung Beim doppelten ICON System ist besonders auf die Aufstellung der beiden Stacks pro Seite zu achten Dies ist wichtig um unerw nschte Ausl schungen oder berh hungen Phasing Effekte im Frequenzgang zu vermeiden Die Subwoofer k nnen durchaus auch Seite an Seite nebeneinander gestellt werden Abbildung 6 Aufstellwinkel zweier ICON Stacks IC 112 LA e Throu Sub Out System Guard BVNet O IC 118 BA System Guard Q Out Throu IC 118 BA System Guard Throu O In Out 2 3 ICON IC 112 LA IM FLUGBETRIEB Zum Fliegen der Mid High Unit verwenden Sie Aeroquip Schlitten optional erh ltlich For AN IC 112 LA Abbildung 7 ICON IC 112 LA mit Aeroquip Schienen Hinweis Verwenden Sie ausschlieflich gepriifte Anschlagmittel z B Half Coupler TV Zapfen Schellen usw um die Sicherheit zu gew hrleisten Die verwendeten Aufhangepunkte m ssen f r die entsprechende Belastung Gewicht ICON IC 112 LA ohne Rollbrett 49 9 kg 110 lbs ausgelegt sein 2 4 VERWENDUNG DER ICON TiLT UNIT Montieren Sie zuerst die B gel der ICON Tilt Unit A am oberen IC 118 BA Subwoofer Drehen Sie daf r die M10 Einschlagmuttern aus dem Geh use und montieren Sie anschlieRend die B gel der Tilt Unit mit den Befestigungsschrauben B lan
15. Zustand verlassen Um diesen Zustand zu erhalten und einen gefahrlosen Betrieb sicherzustellen muss der Anwender die Hinweise und die Warnvermerke beachten die in der Bedienungsanleitung enthalten sind Das Ger t entspricht der Schutzklasse schutzgeerdet DIE SICHERHEIT ZUVERL SSIGKEIT UND LEISTUNG DES GER TES WIRD VON HK AUDIO NUR DANN GEW HRLEISTET WENN Montage Erweiterung Neueinstellung nderungen oder Reparaturen von HK AUDIO oder von dazu erm chtigten Personen ausgef hrt werden die elektrische Installation des betreffenden Raumes den Anforderungen von IEC ANSI Festlegungen entspricht das Ger t in bereinstimmung mit der Gebrauchsanweisung verwendet wird WARNUNG Wenn Abdeckungen ge ffnet oder Geh useteile entfernt werden aufer wenn dies von Hand m glich ist k nnen Teile freigelegt werden die Spannung f hren Wenn ein ffnen des Ger tes erforderlich ist muss das Ger t von allen Span nungsquellen getrennt sein Ber cksichtigen Sie dies vor dem Abgleich vor einer Wartung vor einer Instandsetzung und vor einem Austausch von Teilen Ein Abgleich eine Wartung oder eine Reparatur am ge ffneten Ger t unter Spannung darf nur durch eine vom Hersteller autorisierte Fachkraft nach VBG 4 geschehen die mit den verbundenen Gefahren vertraut ist Lautsprecher Ausg nge die mit dem IEC 417 5036 Zeichen Abb 1 s unten versehen sind k nnen ber hrungsgef hrliche Spannungen f hren Deshalb vor dem Ein
16. amplification system be protected by hearing protectors while this unit is in operation Fuses Replace with IEC 127 5x 20 mms type and rated fuse for best performance only TO PREVENT THE RISK OF FIRE AND SHOCK HAZARD DO NOT EXPOSE THIS APPLIANCE TO MOISTURE OR RAIN DO NOT OPEN CASE NO USER SERVICE ABLE PARTS INSIDE REFER SERVICING TO QUALIFIED SERVICE PERSONNEL Version 1 1 11 2006 IMPORTANT ADVICE ON SAFETY Please read before use and keep for later use The unit has been built by HK AUDIO in accordance with IEC 60065 and left the factory in safe working order To maintain this condition and ensure non risk operation the user must follow the advice and warning comments found in the operating instructions The unit conforms to Protection Class 1 protectively earthed HK AUDIO ONLY GUARANTEE THE SAFETY RELIABILITY AND EFFICIENCY OF THE UNIT IF Assembly extension re adjustment modifications or repairs are carried out by HK AUDIO or by persons authorized to do so The electrical installation of the relevant area complies with the requirements of IEC ANSI specifications The unit is used in accordance with the operating instructions The unit is regularly checked and tested for electrical safety by a competent technician WARNING If covers are opened or sections of casing are removed except where this can be done manually live parts can become exposed If it is necessary to open the unit this must be insulated f
17. autres cordons secteur e V rifiez les DEL de contr le sur votre table de mixage Elles ne doivent pas tre en permanence dans la zone rouge Au besoin r duisez le volume au niveau 4 vitez les distorsions En effet les distorsions ne sont pas seulement de la table de mixage d sagr ables l oreille pour les auditeurs mais elles sont aussi dangereuses e V rifiez les DEL des t moins Limiter sur le panneau de commande de l ICON pour votre installation Veillez donc ce que tous les composants raccord s Mid High Elles ne doivent s allumer que bri vement et en jaune En aucun directement et indirectement au syst me ICON disposent d une puissance cas elles ne doivent rester allum es en jaune de facon permanente Si c tait le suffisante et ne produisent jamais de distorsions parce qu ils sont exploit s cas r duisez au niveau du potentiom tre Gain leur limite maximale Veillez ce que le signal soit d une qualit suffisante pour ICON SERIES LTS 1 0 8 CARACT RISTIQUES TECHNIQUES ICON IC 112 LA Connexions Imp dance d entr e Sensibilit en entr e Niveau d entr e maxi R ponse en fr quence 3 dB R ponse en fr quence 10 dB Sensibilit 1W 1m SPL calcul maximum SPL de cr te max SPL Ampli m diums Ampli aigus Circuits de protection actifs Haut parleur de m diums Aigus Moteur Directivit Fr quence de coupure Points de fixation pour suspension Poign es
18. in which case the Mute button may be engaged If you have not connected a PC to the system set the switch to the Off position The subwoofer s low frequency output is weak e Check the cord connecting the IC 112 LA mid high unit s Sub Out to the IC 118 BA subwoofer s Input The signal sounds distorted Check the LED displays on your mixer Ensure they are not constantly in the red If necessary back off the volume at the mixer Observe the Limiter LEDs on the ICON mid high units control panels They may light up yellow but only briefly Under no circumstances may the yellow LEDs illuminate continuously If this is the case turn down the Gain knobs 11 ICON SERIES LTS 1 0 8 TECHNICAL DATA ICON IC 112 LA Connections Input impedance Input sensitivity Max Input level Frequency response 3 dB Frequency response 10 dB Sensitivity 1W 1m Max SPL calculated Max SPL peak Max SPL Amplifier Mid Amplifier Hi Limiters MF Speaker HF Speaker Directivity Crossover Frequency Rigging points Handles Grille Castors Accessories Dimensions BxHxT Weight ICON IC 118 BA Connections Input impedance Input Sensitivity Max Input Level Frequency response 3 dB Frequency response 10 dB Sensitivity 1W 1m Max SPL calculated Max SPL peak Max SPL Amplifier Sub Limiters Woofer Pole mount Handles Grille Castors Accessories Dimensions WxHxD Weight 1x XLR
19. l utilisation du potentiom tre Gain EET umm 5 Evitez les boucles de masse Si par exemple la table de mixage est raccord e la terre via le cordon d alimentation secteur et qu elle n est pas aliment e sur le m me circuit lectrique que l ICON une boucle de masse est susceptible Monet Desc Pace Heb 2 2 dion d apparaitre C est pourquoi vous devez toujours raccorder le systeme ICON one et la table de mixage sur le m me circuit m me phase ATTENTION ne M icon ai couvrez jamais la terre de la fiche secteur danger de mort 6 ACCESSOIRES DE L ICON e Jeu de cables HK AUDIO ICON compos de quatre c bles CAT5 RJ45 Module d interface BVNet e Unit d inclinaison HK AUDIO Dispositif d inclinaison de l unit Mid High ICON L unit d inclinaison se visse sur le c t du subwoofer et de l unit Mid High les angles possibles sont 5 10 et 15 Ils se r glent en suspendant l unit Mid High dans les encoches correspondantes de l unit d inclinaison Fig 14 Devise Panel properties Options Jeu de housses ICON HK AUDIO compos de 4 housses de subwoofer et 1 Speakers Properties Indiquent les noms des appareils des haut parleurs et de 2 housse de Mid High extr mement solides imperm ables et rembour des filtres r es elles prot gent durablement le syst me ICON durant le transport 2 Logs Indique l
20. me aux conditions locales s effectuent via un galiseur param trique 8 bandes et un galiseur tag res Shelving 2 bandes un filtrage passe haut et passe bas ainsi que des fonctions Gain Delay Phase et Mute L ICON LTS r pond parfaitement bien toutes les exigences des grands Top 40 Gigs festivals en plein air sessions en club concerts sous chapiteau spectacles en tourn e ou discoth ques mobiles Il constitue donc le premier choix pour les soci t s de location ou les groupes professionnels L quipe HK AUDIO vous souhaite pleine satisfaction avec votre ICON LTS SOMMAIRE 1 COMPOSANTS DU SYSTEME gt nos XX 1 2 Unit Mid High chargement par pavillon IC 112 Xx 1 1 Subwoofer filtre passe bande IC 118 Xx D XX 2 INSTALLATION ET CABLACE anne 16 PME ER ON Sram 16 22 Syst me ICON LTS TE 16 24 ICON IC 12 LA suspendu ica 17 2 4 Utilisation de l unit d inclinaison ICON eene 17 3 RACCORDEMENTS ET COMMANDES 17 3 1 Commandes connexions de signaux et t moins de contr le ICON IC 112 LA 17 3 2 Commandes connexions de signaux et t moins de contr le ICON IC 118 BA 18 4 LOGICIEL DISTANCE PODWARE INTERFACE BVN
21. n de funcionamiento ajustada tiene que coincidir con la tensi n de la red del lugar La conexi n a la red el ctrica se efectuar con la fuente de alimentaci n o con el cable de red que se entreguen con el aparato Fuente de alimentaci n una linea de conexi n da ada no se puede sustituir La fuente de alimentaci n no puede volver a ponerse en funcionamiento e Evite una conexi n de la red el ctrica a distribuidores con muchas tomas de corriente El enchufe para el suministro de corriente tiene que estar cerca del aparato y ser de f cil acceso SITUACION El aparato deber a estar situado en una superficie limpia y totalmente horizon tal El aparato no puede estar expuesto a ning n tipo de sacudidas durante su funcionamiento Coloque el dispositivo de forma que el interruptor de la red quede accessible facilmente e Se deben evitar la humedad y el polvo El aparato no puede ponerse en funcionamiento cerca del agua la ba era el lavamanos la pila de la cocina un recinto con tuber as de agua la piscina o en habitaciones h medas Tampoco se pueden poner objetos llenos de l qui do jarrones vasos botellas etc encima de l Procure que el aparato tenga suficiente ventilaci n Las aberturas de ventilaci n existentes no se deben bloquear ni tapar nunca El aparato debe estar situado como m nimo a 20 cm de la pared El aparato s lo se puede montar en un rack si se ha procurado la suficiente ventilaci n y
22. of identifying a device that is the DSP module in a mid high unit when several devices are connected and their panels are open in PodWare Simply click this icon and watch the Wink LEDs to see which one flashes 3 Mute This button mutes all devices connected to the network 4 Launch all Panels This function opens the panels of all devices connected to the network PodWare generated a device panel for every connected speaker cabinet equipped with a DSP module You can view edit and monitor parameters and controlling functions at two different window levels in this device panel THE EQ DELAY DEVICE PANEL HE al Poeme etes Dese tel AAA a EHEM 1 ICON 2 2 11 1 Figure 13 The Delay device panel 1 Equalizer with 8 fully parametric bands Variable parameters Freq 10 Hz to 25 6 kHz Quality gt 0 17 to 14 2 Q factor or 0 102 to 5 25 octaves Gain 15 dB to 15 dB Use the mouse to operate the EQ or enter values direct ly You can t link devices but you can copy and paste EQ settings 2 Low shelf high shelf filters Variable parameters Freq 10 Hz to 25 6 kHz Slope 6dB to 12dB Gain 15 dB to 15 dB If you want to apply values from one device to another you must copy and paste them 3 Low pass high pass filters Variable parameters Freq 20 2 Hz to 25 6 kHz filter type 1st order Bessel Butterworth Linkwitz Riley and Bess
23. par le fabricant ou vendu en combinaison avec l appareil Les indications du fabricant pour l installation de l appareil sont suivre et les accessoires d installation conseill s par le fabricant sont utiliser Un ensemble support et appareil doit tre d plac avec pr caution Des mouvements brusques et des rev tements de sol irreguliers peuvent entrainer la chute de l ensemble Equipements suppl mentaires Ne jamais utiliser un quipement suppl men taire n ayant pas t conseill par le fabricant ceci pouvant entrainer des accidents Afin de prot ger l appareil pendant un orage ou s il ne doit pas tre utilis pendant un certain temps il est conseill d enlever la prise au secteur Ceci vite des dommages d s la foudre ou des coups de tension dans le r seau courant alternatif Fig 1 MN Fig 2 IMPORTANTI AVVERTIMENTI DI SICUREZZA Leggere attentamente prima dell uso e conservare per un utilizzo successivo L apparecchio amp stato costruito dalla HK AUDIO secondo la normativa europea IEC 60065 ed ha lasciato il nostro stabilimento in stato ineccepibile Per garantire il mantenimento di tale stato e un utilizzo assolutamente privo di rischi l utente tenuto ad osservare le indicazioni e gli avvertimenti di sicu rezza contenuti nelle istruzioni per l uso L apparecchio rispecchia il livello di sicurezza collegato a terra Sicurezza affidabilit e prestazioni dell apparecchio vengono garantiti da
24. quality RJ 45 compatible Ethercon cables and further components using cat 5 cables equipped with RJ 45 plug in connectors Speaker cabinets are detected in the network by their factory assigned names However you are free to edit these names as you see fit Activate the Flash function to locate devices It causes the LED on the front of the given cabinet to flash for about six seconds 4 3 INSTALLATION AND FIRMWARE UPDATES Please read these instructions carefully before you begin installing software PREPARATIONS Required Files You must load the following files to a folder on the hard drive before you can install this software e Setup exe e Setup ini e SetupSecure msi e Code for PodWare txt contains the installation access code e Updating Windows XP dotnetfx exe dotframework Heads up It is necessery that you have installed at least the dotnetframework 2 0 Service Pack 1 on your computer when using Podware When the installation routine begins the computer may connect to the Microsoft server to download an update called dotnetfx exe This update is indispensable PodWare will not run without it You may install this approx 22 Mb file offline before you launch the installation routine Required Hardware e Windows computer XP Vista with an Ethernet interface CATS cable BVNet interface INSTALLING AND CONFIGURING PoDWARE Installing Pod Ware Check if all cables are connected properl
25. s installe alors automatiquement Relancez ensuite l ordinateur m me si le syst me ne vous y invite pas S lection du port COM e Ouvrez le menu D marrer de Windows puis s lectionnez PodWare Ouvrez ensuite S lection R seau Port Com puis s lectionnez le port Com 1 4 auquel vous avez raccord le c ble s rie menant l interface BVNet Astuce Dans le gestionnaire de p riph riques Windows vous pouvez vous renseigner sur le port Communication D marrer Panneau de configuration Syst me 29 ICON SERIES LTS 1 0 gt Mat riel gt Gestionnaire de p riph riques gt Ports COM amp LPT Vous pouvez ici v rifier nouveau si un c ble USB est correctement install sur l adaptateur s rie Ouvrez le menu D marrer de Windows XP et s lectionnez PodWare Le logiciel se lance Vous trouverez des indications sur l utilisation de PodWare sous Menu gt Aide gt Helptopics sous forme de liste HTML Installation de l interface BVNet Vous trouverez des informations relatives l installation de l interface BVNet dans la notice technique de l interface 4 4 UTILISATION DU LOGICIEL Apr s l installation vous pouvez ouvrir le PodWare par un double clic e Connectez pr sent le syst me ICON l interface BVNet puis connectez l ordinateur portable HK Audio BV Network File Preferences Network Device Panel Help Fig 12 Fonctions de base du PodWare
26. seg n VBG 4 que conozca a fondo los peligros que ello conlleva Las salidas de altavoces que est n provistas de la caracter stica IEC 417 5036 figura 1 v ase abajo pueden conducir tensiones peligrosas al contacto Por ello es indispensable que antes de poner en marcha el aparato la conexi n se haya realizado nicamente con el cable de empalmes recomendado por el productor Las clavijas de contacto al final de los cables conectores tienen que estar atornilladas o enclavadas a la carcasa en tanto que sea posible S lo se pueden utilizar fusibles del tipo IEC 127 con la intensidad de corriente nominal indicada El uso de fusibles reparados o la puesta en cortocircuito del soporte es inadmisible El empalme del conductor de protecci n no se puede interrumpir en ning n caso Las superficies provistas de la caracteristica HOT figura 2 v ase abajo los paneles de fondo trasero o las protecciones con ranuras de ventilaci n los cuerpos de ventilaci n y sus protecciones as como las v lvulas electr nicas y sus protecciones pueden alcanzar temperaturas muy altas durante el funcionamiento y por ello no se deber an tocar Niveles elevados de la intensidad de sonido pueden causar continuos da os auditivos por ello debe evitar acercarse demasiado a altavoces que funcionen a altos niveles En tales casos utilice protecciones auditivas ACOMETIDA A LA RED El aparato est proyectado para un funcionamiento continuo La tensi
27. similar devices If the unit is suddenly moved from a cold to a warm location condensation can form inside it This must be taken into account particularly in the case of tube units Before switching on wait until the unit has reached room tempe rature Accessories Do not place the unit on an unsteady trolley stand tripod base or table If the unit falls down it can cause personal injury and itself become damaged Use the unit only with the trolley rack stand tripod or base re commended by the manufacturer or purchased together with the unit When setting the unit up all the manufacturer s instructions must be followed and the setup accessories recommended by the manufacturer must be used Any com bination of unit and stand must be moved carefully A sudden stop excessive use of force and uneven floors can cause the combination of unit and stand to tip over Additional equipment Never use additional equipment which has not been recommended by the manufacturer as this can cause accidents To protect the unit during bad weather or when left unattended for prolonged periods the mains plug should be disconnected This prevents the unit being damaged by lightning and power surges in the AC mains supply Diagram 1 M Diagram 2 WICHTIGE SICHERHEITSHINWEISE Bitte vor Gebrauch lesen und f r sp teren Ge brauch aufbewahren Das Ger t wurde von HK AUDIO gem IEC 60065 gebaut und hat das Werk in sicherheitstechnisch einwandfreiem
28. the laptop and the system you can manually adjust all the key sound shaping parameters such as parametric and shelving EQs delay phase invert and gain to suit the given location What s more you can view readings of all controlling functions that is system driver and power amp protection performance stats online in real time while the event is underway and afterwards review the system s performance over the last 72 operating hours 1 ICON SYSTEM COMPONENTS 1 1 IC 112 LA THE HORN LOADED MiD HIGH UNIT iram Soran 112 LA Figure 1 IC 112 LA Loaded with a 12 HK AUDIO Custom Speaker and a 1 4 compression driver feeding a 60 x 40 CD horn the IC 112 LA mid high unit delivers remarkably articulate richly detailed audio images and exemplary directivity It also houses a DSP module which serves as the given system s digital control room This module sends the signal to a dual channel crossover From there it goes to two Class D power amps one delivers 300 watts at 8 ohms to the high frequency driver the other 500 watts at 8 ohms to the horn loaded 12 woofer Residing in a dedicated compartment at the rear of the cabinet all electronic circuitry is accessed and controlled using the features on the control panel It also provides connectors and LEDs indicating the system s operating status 1 2 IC 118 BA THE BAND PASS SUBWOOFER DR Gees Figure 2 IC 118 BA The IC 118 BA subwoofer si
29. une connexion r seau User Settings Le logiciel pour PC PodWare et l interface BVNet entre ordinateur portable PC et syst me tous deux fournis permettent le traitement manuel des r glages du son avec tous les param tres essentiels l adaptation aux conditions locales 4 1 COMPOSANTS REQUIS Pour ce faire il vous faut un PC ou un ordinateur portable tournant sous WIN XP ou Vista une interface BVNet 1 c ble USB 6 c bles CATS Remarque Le commutateur User Settings On Off de l unit IC 112 LA Mid High doit obligatoirement tre plac sur ON pour l utilisation avec logiciel PC 4 2 SURVEILLANCE Une ligne de donn es interne permet de surveiller l int gralit du syst me en cours de fonctionnement Les donn es relatives la temp rature de fonctionnement des tages de puissance et l tat des haut parleurs sont stock es pour un total de 72 heures de fonctionnement Elles peuvent d s lors aussi tre lues ult rieurement ce qui permet de suivre les tats de fonctionnement des derniers concerts IC 112 LA BVNet RS485 RJ45 Cable Interface IC 118 BA USB Cable IC 118 BA E Laptop Fig 11 Conception du syst me sch ma de c blage Le branchement des haut parleurs sur un PC ordinateur portable s effectue via un c ble CATS bifilaire avec connecteurs RJ45 classiques l interface RS485 travaille sur un bus commun si bien qu un seul ordinateur suff
30. 18 18 15 1 15 12 0 05 0 1 0 2 0 5 kHz Max SPL Deg 150 100 50 Directivity horizontal 2D 50 100 150 Grooup Delay Grooup Delay ICON SERIES LTS 1 0 BIENVENUE DANS LA FAMILLE HK AUDIO Nous vous remercions d avoir opt pour un produit HK AUDIO ICON LTS Long Throw System est un syst me actif commande num rique et chargement par pavillon qui fixe de nouvelles r f rences en termes de performances et de gestion num rique du signal pour des solutions de sonorisation actives ICON LTS a t principalement concu pour une utilisation en empilage au sol pour les manifestations dans lesquelles il serait impossible trop complexe ou trop co teux de suspendre un tel syst me Il allie utilisation simple et intuitive restitution du son impressionnante et naturelle et intelligibilit optimale ICON LTS la solution syst me totalement active pour un son parfait l unit Mid High chargement par pavillon avec contr leur num rique int gr constitue le centre de command d un stack compl t par deux subwoofers filtre passe bande Associ une technologie haut de gamme de la classe D il fournit une puissance sonore longue port e hautement exploitable Le logiciel PC Controller permet de g rer des param tres importants comme le niveau la temp rature de l tage de puissance ou l imp dance Le r glage individuel et l adaptation du syst
31. 1x XLR Input 1x XLR Through 2x Ethernet RJ45 Internal System Guard 20 kohms 4 dBu 22 dBu 41 Hz fx 33 Hz fx 105 dB 138 dB bas sur la capacit de charge de cr te 138 dB SPL 1096 THD 90 Hz 100 Hz 136 dB SPL 1096 THD 1x 2000 W Classe D Filtre subsonique System Controller with Peak Limiter 18 Neodym 2x Plateau filet M20 8 poign es noy es Grille m tallique noire avec mousse d isolation acoustique Planche roulettes avec roulettes orientables 4 x 100 mm Unit d inclinaison capot interface BVNet 50 X 90 x 81 cm 20 1 2 x 28 1 2 x 2831 8 54 1 119 2 165 sans planche roulettes CARACT RISTIQUES TECHNIQUES G N RALES Puissance absorb e max Courant absorb maxi Fusibles internes Plages de tension Raccordement au secteur 1050 watts IC 112 LA 1880 watts IC 118 BA 4 5 IC 112 LA 8 1 A IC 118 BA 4 AT 10 AT IC 112 LA 10 AT IC 118 BA 220 V 240 V Neutrik Powercon F r die nachfolgend bezeichneten Erzeugnisse ICON IC 112 LA ICON IC 118 BA wird hiermit best tigt dass sie den wesent lichen Schutzanforderungen entsprichen die in der Richtlinie des Rates zur Angleichung der Rechtsvorschriften der Mitgliedsstaaten ber die elektromagnetische Vertr glichkeit 2004 108 EG und der Niederspannungsrichtli nie 2006 95 EG festgelegt sind Diese Erkl rung gilt f r alle Exemplare und best tigt die Ergebnisse der Messungen die durch die Qualit tssicherung der
32. B sse aus dem Subwoofer e berpr fen Sie das Verbindungskabel vom Sub Out der IC 112 LA Mid High Unit zur Eingangsbuchse des IC 118 BA Subwoofers Die Musikwiedergabe scheint verzerrt zu sein e berpr fen Sie die LED Anzeigen an Ihrem Mischpult Sie sollten sich nicht st ndig im roten Bereich befinden Nehmen Sie gegebenenfalls die Lautst rke am Mischpult zur ck e Beobachten Sie die LEDs der Limiter Anzeigen im Bedienfeld von ICON Mid High Diese sollten nur kurz gelb aufleuchten Keinesfalls d rfen sie ohne Unterbrechung gelb aufleuchten In diesem Fall drehen Sie die Gain Regler zur ck ICON SERIES LTS 1 0 8 TECHNISCHE DATEN ICON IC 112 LA Anschl sse Eingangsimpedanz Eingangsempfindlichkeit Max Eingangspegel Frequenzgang 3 dB Frequenzgang 10 dB Empfindlichkeit 1W 1m Max SPL calculated Max SPL peak Max SPL Verst rker Mittelton Verst rker Hochton Aktive Schutzschaltungen Mitteltonlautsprecher Hocht ner Treiber Directivity Trennfrequenz Flugpunkte Griffe Frontgrill Rollen Zubeh r Abmessungen BxHxT Gewicht ICON IC 118 BA Anschl sse Eingangsimpedanz Eingansempfindlichkeit Max Eingangspegel Frequenzgang 3 dB Frequenzgang 10 dB Empfindlichkeit 1W 1m Max SPL calculated Max SPL peak Max SPL Verstarker Subwoofer Aktive Schutzschaltungen Basslautsprecher Hochstanderflansch Griffe Frontgrill Rollen Zubeh r Abmessungen BxHxT Gewicht
33. C 118 BA e DEL Limit Cette DEL indique l utilisation des limiteurs de cr te des tages de puissance de la classe D an augmen tation maximale de la tension de sortie e DEL Signal Cette DEL s allume en cas de signal d entr e 56 dBU e DEL Power ON Cette DEL s allume en cas de branchement au r seau E ICON SERIES AUDIO IC 118 BA Made in Germany Fig 10 Commandes de l ICON IC 118 BA e DEL Temp Limit Cette DEL s allume lorsque l lectronique au niveau de l un des trois capteurs int gr s cet effet atteint une temp rature critique Dans ce cas l tage de puissance redescend de 6 dB jusqu ce que la temp rature soit nouveau situ e dans une plage normale la DEL s teint alors e DEL Amp Cette DEL s allume la mise sous tension pendant l initialisation de l tage de puissance env 5 secondes puis s teint durablement indique l tat Mute pour la protection de l appareil p ex d faillance dans l ampli Attention cas de maintenance s allume pendant le fonctionnement en cas d erreur dans le syst me p ex r glage maximum pour les haut parleurs faible valeur ohmique La Del s teint d s que la puissance diminue 4 LOGICIEL DISTANCE PODWARE INTERFACE BVNET e Pour la commande et la surveillance distance de votre syst me En plus des param tres d usine il est possible de commander le syst me distance l aide d un PC via
34. CON LTS Long Throw System ist ein digital gesteuertes und horngeladenes Aktivsystem das neue Ma st be in Sachen Performance und digitalem Signalmanagement bei aktiven Beschallungsl sungen setzt ICON LTS wurde haupts chlich f r den Einsatz im Ground Stacking Betrieb konzipiert f r Veranstaltungen bei denen das Fliegen einer PA nicht m glich zu aufw ndig oder mit dem Budget nicht vereinbar w re Es vereint einfache und intuitive Handhabung mit druckvoller nat rlicher Klangwiedergabe und optimaler Sprachverst ndlichkeit ICON LTS die vollaktive Systeml sung f r perfekten Sound Die horngeladene Mid High Unit mit integriertem Digitalcontroller bildet das Steuerzentrum eines Stacks das durch zwei Bandpass Subwoofer erg nzt wird Kombiniert mit modernster Class D Endstufen Technologie ergibt dies einen hohen verwertbaren Schalldruck bei gro er Reichweite Via PC Controller Software werden wichtige Parameter wie Pegel Endstufentemperatur und Impedanz berwacht F r individuelle Einstellung und Anpassung des Systems an die r umlichen Gegebenheiten stehen ein 8 fachparamterischer EQ und zweifach Shelving EQ Hoch Tiefpass Gain Delay Phase und Mute zur Verf gung Die wechselnden Anforderungen bei gr eren Top 40 Gigs City Open Airs Club Gigs Festzeltbeschallungen Road Shows oder mobilen Disco Veranstaltungen machen ICON LTS zur ersten Wahl f r Vermietfirmen und professionelle Bands Viel Erfolg mit
35. ET 19 AT Composants CG ONS 9 PE MEME 9 4 3 Installation et mise jour du micrologiciel sss 9 4 4 Utilisation du logiciel eegene 10 2 PROCS ET ASTUOCES 11 6 ACCESSOIRES ICON 11 7 D PISTAGE DES PANNES conan 11 8 CARACT RISTIQUES 8 2 2 12 1 16124 22 KONTIS m 22 Registre des illustrations qM EM D P is A a caen dun mot Fig 4 Sch ma de c blage du syst me ICON LTS Stach X Fig 5 Sch ma des connexions du syst me ICON LTS double Fig 6 Angle de montage de deux stacks ICON en 6 Fig 7 ICON IC 112 L avec rails Aeroquip nn 7 Fig 8 Montage et utilisation de l unit d inclinaison ICON 7 Fig 9 Commandes PICON Mid High ENNEN 7 Fig 10 Commandes de l ICON IC 118 BA 8 Fig 11 Conception du syst me sch mas de c blage 9 Fig 12 Fonctions de base du 2 222 10 Fig 13 Device Panel EQ Delay nn 10 Fig 14 Device Panel pr
36. High Unit aufgeschraubt die w hlbaren Winkel betragen 5 10 und 15 und werden durch Einh ngen der Mid High Unit in der Tilt Unit eingestellt e HK AUDIO Schutzh llensatz ICON bestehend aus 4 Subwoofer Schutzh llen und 2 Mid High Schutzh llen u erst rei fest wasserabweisend und dick gepolstert f r einen dauerhaften Schutz des ICON Systems beim Transport Mehr Informationen zum Original HK AUDIO Zubeh r erhalten Sie bei Ihrem HK AUDIO H ndler oder im Internet unter www hkaudio de 7 FEHLERBEHEBUNG Die Power On LED leuchtet beim Einschalten nicht rot auf e berpr fen Sie ob das Netzkabel am Mains Input angeschlossen ist Vergewissern Sie sich dass das Netz Spannung f hrt Pr fen Sie ob evtl die Haussicherung ausgel st hat Die Power On LED leuchtet rot auf aber es kommt kein Ton aus den Boxen berpr fen Sie die Anschlusskabel die Sie an den Anschl ssen Input angeschlossen haben Pr fen Sie ob die Signalquellen Mischpult Keyboard CD Player usw eingeschaltet sind Sind die Gain Regler aufgedreht berpr fen Sie die Signalkabel auf evtl Besch digungen e berpr fen Sie den Schalter User Settings On Off Steht dieser auf On werden die letzten Einstellungen ber die PC Software geladen bei denen unter Umst nden die Mutefunktion eingeschaltet ist Wenn sie keinen PC an das System angeschlossen haben schalten sie auf User Settings Off Es kommen nur wenig
37. IEU D INSTALLATION L appareil doit tre plac sur une surface de travail propre et horizontale L appareil en marche ne doit en aucun cas subir des vibrations Posez l appareil en place de sorte que l interrupteur du r seau reste acces sible facilement Evitez dans la mesure du possible poussi re et humidit L appareil ne doit pas tre plac proximit d eau de baignoire lavabo vier pi ce d eau piscine ou dans une pi ce humide Ne placez aucun vase verre bouteille ou tout objet rempli de liquide sur l appareil L appareil doit tre suffisamment a r Ne jamais recouvrir les ouvertures d a ration L appareil doit tre plac 20 cm du mur au minimum L appareil peut tre mont dans un Rack si une ventilation suffisante est possible et si les conseils de montage du fabricant sont suivis Evitez les rayons de soleil et la proximit de radiateurs chauffages etc Une condensation d eau peut se former dans l appareil si celui ci est trans port brusquement d un endroit froid un endroit chaud Ceci est particu li rement important pour des appareils tubes Avant de brancher l appareil attendre qu il ait la temp rature ambiante Accessoires L appareil ne doit tre plac sur un chariot support tr pied b ti ou table instable Une chute de l appareil peut entrainer aussi bien des dommages corporels que techniques Utilisez l appareil uniquement avec un chariot Rack support tr pied ou b ti conseill
38. Icon SERIES MANUAL 1 0 LTS SYSTEM IMPORTANT SAFETY INSTRUCTIONS Before connecting read instructions Read all of these instructions Save these instructions for later usel Follow all warnings and instructions marked on the product Do not use this product near water i e bathtub sink swimming pool wet basement etc Do not place this product on an unstable cart stand or table The product may fall causing serious damage to the product or to persons Slots and openings in the cabinet and the back or bottom are provided for ventilation to ensure reliable operation of the product and to protect it from overheating these openings must not be blocked or covered This product should not be placed in a built in installation unless proper ventilation is provided This product should not be placed near a source of heat such as a stove radiator or another heat producing amplifier Use only the supplied power supply or power cord If you are not sure of the type of power available consult your dealer or local power company Do not allow anything to rest on the power cord Do not locate this product where persons will walk on the cord Never break off the ground pin on the power supply cord Power supply cords should always be handled carefully Periodically check cords for cuts or sign of stress especially at the plug and the point where the cord exits the unit The power supply cord should be unplugged when the unit is to b
39. Ihrem ICON LTS w nscht Ihnen Ihr HK AUDIO Team INHALT 1 ICON SYSTEMKOMPONENTEN 2 15 1 2 IC 112 LA Horngeladene Mid High Unit esses 15 1 1 IC 118 BA Bandpass Subwoofer essere nennen 15 ES c 15 2 AUFSTELLUNG UND 4 16 MEM ae a a om in 16 22 Doppeltes ICON LTS System une 16 23 ICON IC 112 LA im Flugbetrieb 3 17 2 4 Verwendung der ICON Tilt Unit esee tette 17 3 ANSCHL SSE UND 17 3 1 ICON IC 112 LA Bedienelemente Signalanschl sse Kontrollleuchten 17 3 2 ICON IC 118 BA Bedienelemente Signalanschl sse Kontrollleuchten 18 4 REMOTE SorrWARE PODWARE 19 43 Erforderliche Komponenten 19 42 WD CTW TE 19 4 3 Installation und Firmware Update 19 4 4 Bedienung der Software nn 20 5 TIPPS UND TRICKS u 21 6 ee 21 7 EES 21 8 TECHNISCHE DATEN ee ee S UNES 22 i89 iba 22 22 Abbildungsverzeichnis ICT 15 Ee hr 15 Abb e e E cm 16 Abb 4 Verkabelun
40. Line In 1x XLR Line Through 1x XLR Sub Out 2x BVNet RJ45 IN OUT 1x Ethernet RJ45 Internal System Guard 20 kOhm 16 dBu 4 dBu o dBu 10 dBu variable 22 dBu 134 Hz 17 kHz LTS System Filter 108 Hz 17 kHz 109 dB 120 Hz 16 kHz 139 dB based on peak power handling capacity 136 dB SPL 1096 THD 131 dB SPL 1096 THD 120 Hz 12 kHz 134 dB SPL 1096 THD 120 Hz 5 kHz 1000 W Class D 4 Ohm 1x W Class D 4 Ohm RMS Limiter Peak Limiter Subsonic Filter 12 Neodym 1 4 60 x 40 CD horn 900 Hz 24 dB Oct Aeroquip 4 integrated Metal Grille with black acoustic foam Dolly with four 100 mm castors ICON Tilt Unit 5 10 15 dust cover 50 x 60 x 81 cm 19 11 16 x 23 5 8 x 31 7 8 49 9 kg 110 lbs without dolly 1x XLR Input 1x XLR Through 2x Ethernet RJ45 Internal System Guard 20 kOhm 4 dBu 22 dBu 41 Hz fx 33 Hz fx 105 dB 138 dB based on peak power handling capacity 138 dB SPL 1096 THD 90 Hz 100 Hz 136 dB SPL 1096 THD 1x 2000 W Class D 4 Ohm Subsonic Filter System Controller with Peak Limiter 18 Neodym Two M20 threaded base plates 8 integrated Metal Grille with black acoustic foam Dolly with four 100 mm castors dust cover 50 x 90 81 cm 20 1 2 x 28 1 2 x 2831 8 54 1 119 2 lbs without dolly 1 Measurements taken under half space conditions GENERAL TECHNICAL DATA Max Power Consumption Max Current Consumption Interna
41. Signal LED This LED lights up when the unit detects an incoming signal with 56 dBU e Power ON LED This LED lights up when a mains power supply is connected e Temp Limit This LED lights up when one of the three integrated sensors detects that electronic components have reached critical temperature The power amp attenuates the signal by 6 dB until the temperature drops back to the normal operating range at which time the LED extinguishes e Amp This LED lights up for about five seconds while amp powers up when the device is switched on after which it extinguishes continuously to indicate the device has been muted for its own protection possibly due to some flaw in the amp The device definitely requires service when the amp is up and running and an error occurs for example if it is operating at peak level while driving speakers whose impedance is too low The LED extinguishes when the amp s power output is reduced e Wink LED Sited in the mid high unit s front grille this yellow LED flashes several times when address the DSP module in PodWare that is when you click the Locating button on the application s user panel 3 2 ICON IC 118 BA THE IC 118 BA s CONTROL FEATURES e Phase Use this switch to determine the IC 118 BA s polarity 0 The IC 118 BA s polarity is positive in phase 180 The IC 118 BA s polarity is negative out of phase The IC 118 BA s polarity is positive in phase wh
42. appareil est activ e clignote pendant environ 6 secondes 4 3 INSTALLATION ET MISE JOUR DU MICROLOGICIEL Veuillez lire attentivement cette notice d emploi avant de commencer l installation du logiciel PR PARATION Fichiers requis Les fichiers suivants sont requis pour l installation du logiciel 115 doivent tre sauvegard s dans un r pertoire sur le disque dur e Setup exe e Setup ini e SetupSecure msi Code pour PodWare txt contient le code de d verrouillage pour l installation du logiciel Update Windows XP avec dotnetfx exe dotframework Attention Pour faire fonctionner Podware il est in dispensable que dotnetframework 2 0 Service Pack 1 minimum soit install sur votre ordinateur Remarque importante Il se peut qu au d but de l installation une connexion soit tablie avec le serveur Microsoft afin d effectuer une mise jour avec l extension dotnetfx exe Cette op ration doit imp rativement tre effectu e pour que PodWare puisse tre utilis Ce fichier 22 Mo environ peut aussi tre install auparavant hors ligne Configuration requise e PC sous Windows XP Vista avec interface Ethernet C ble CATS Interface BVNet INSTALLATION ET CONFIGURATION DE PODWARE Installation de PodWare ee V rifiez que tous les c bles sont branch s et que le syst me est sous tension Double cliquez sur Setup exe et suivez les instructions qui s affichent l cran Le logiciel
43. are followed If the product has been dropped or the cabinet has been damaged If the product exhibits a distinct change in performance indicating a need of servicel Adjust only these controls that are covered by the operating instructions since improper adjustment of other controls may result in damage and will often require extensive work by a qualified technician to restore the product to normal operation Exposure to extremely high noise levels may cause a permanent hearing loss Individuals vary considerably in susceptibility to noise induced hearing loss but nearly everyone will lose some hearing if exposed to sufficiently intense noise for a sufficient time The U S Government s Occupational Safety and Health Administration OSHA has specified the following permissible noise level exposures Duration Per Day In Hours Sound LeveldBA Slow Response 8 90 6 92 4 95 3 97 2 100 11 2 102 1 105 1 2 110 1 4 or less 115 According to OSHA any exposure in excess of the above permissible limits could result in some hearing loss Ear plug protectors in the ear canals or over the ears must be worn when ope rating this amplification system in order to prevent a permanent hearing loss if exposure is in excess of the limits as set forth above To ensure against poten tially dangerous exposure to high sound pressure levels it is recommended that all persons exposed to equipment capable of producing high sound pressure levels such as this
44. are quest ultimo agli altoparlanti servendosi esclusiva mente del cavetto d allacciamento indicato dal produttore Tutte le spine ei cavi di collegamento devono essere awvitati o fissati all involucro dell apparecchio per quanto possibile Utilizzare esclusivamente fusibili del tipo IEC 127 con la indicata corrente nominale L utilizzo di fusibili di sicurezza non integri e la messa in corto circuito del sostegno di metallo sono proibite Non interrompere mai il collegamento con il circuito di protezione Superfici contrassegnate dalla parola HOT vedi illustrazione 2 a fondo pag cosi come griglie di aerazione dispositivi di raffreddamento e i loro rivestimenti di protezione oppure valvole e i relativi rivestimenti protettivi possono surriscaldarsi notevolmente durante l uso e per questo motivo non vanno toccate L ascolto di suoni ad alto volume pu provocare danni permanenti all udito Evitate perci la diretta vicinanza con altoparlanti ad alta emissione di suono e utilizzate cuffie protettive in caso ci non sia possibile ALIMENTAZIONE L apparecchio concepito per il funzionamento continuo La tensione di esercizio deve corrispondere alla tensione di rete a cui ci si allaccia L allacciamento alla rete elettrica avviene tramite alimentatore o cavetto d alimentazione consegnato insieme all apparecchio Alimentatore un cavo di connessione danneggiato non pu essere sostituito L alimentatore non pu pi essere utilizzato
45. ation Abbildung 2 IC 118 BA mit Hilfe des BVNet Interface und einem Laptop Best ckt mit einem 12 HK AUDIO Custom Speaker ferngesteuert werden Die mitgelieferte PC und einem 1 4 Kompressionstreiber mit 60 x Der IC 118 BA Subwoofer ist in einem Bandpass Software PodWare und das zwischen Laptop 40 CD Horn liefert die IC 112 LA Mid High Unit geh use untergebracht Das obere Geh use dient und System geschaltete BVNet Interface eine beindruckende Aufl sung bei gleichzeitig als eigentliches Lautsprechergeh use f r den 18 erm glichen die manuelle Bearbeitung der vorbildlicher Directivity Ebenfalls in der Mid Lautsprecher Davon getrennt befindet sich dahinter Sound Einstellungen mit allen wichtigen High Unit befindet sich die digitale Schaltzentrale das Geh use f r die Endstufe Parametern zur Anpassung des Systems an die des jeweiligen Systems das DSP Modul Von Alle Parameter zur Steuerung des Subwoofers rtlichen Gegebenheiten Au erdem lassen sich dort wird das Signal ber eine zweikanalige werden ber die Sub Out Buchse der Mid High Unit dar ber auch alle berwachungsfunktionen ber Frequenzweiche an die beiden Class D Endstufen an den Subwoofer bertragen den Zeitraum der letzten 72 Betriebsstunden gef hrt die eine Leistung von 1x 300 W 8 Ohm f r Wichtiger Hinweis Der IC 118 BA ist ein System auslesen d h Leistungsdiagnose berwachung den Hochtontreiber und 1x 500 8 Ohm f r den Subwoofer der f r das Zusammenspiel
46. ature The power amp attenuates the signal by 6 dB until the temperature comes drops to the normal operating range at which time the LED extinguishes e Amp This LED lights up for about five seconds while amp powers up when the device is switched on after which it extinguishes continuously to indicate the device has been muted for its own protection possibly due to some flaw in the amp The device definitely requires service when the amp is up and running and an error occurs for example if it is operating at peak level while driving speakers whose impedance is too low The LED extinguishes when the amp s power output is reduced 4 PODWARE REMOTE CON TROL BVNET INTERFACE e This combination of application and interface lets you control your system remotely The system may be controlled locally using the factory settings or remotely using a networked PC and your user settings An included PC software application called PodWare in combination with a BVNet interface that connects your laptop or PC to the system lets you manually adjust all the sound shaping settings to suit the given location 4 1 REQUIRED COMPONENTS Here s what you need or laptop running a WIN XP or Vista operating system A BVNet interface module One USB cable Six Cat 5 cables Note Set the User Settings On Off switch on the IC 112 LA mid high unit to On for use with the PC software 4 2 CONTROLLING An internal
47. cation de la sensibilit en entr e du signal d entree existant s effectue au moyen de quatre r glages de base 16 dBu 4 dBu o dBu et 10 dBu Le r glage standard des syst mes ICON est 4 dBu Avant d allumer le syst me assurez vous que celui ci est reli aux subwoofers via Sub Out et que tous les autres composants raccord s sont d j sous tension Concr tement la table de mixage raccord e ainsi que toutes les autres sources de signal claviers amplis d instruments effets etc doivent avoir t activ s En cas d apparition de distorsions ou de saturations v rifiez les sources de signal et r duisez si possible le signal de sortie correspondant Si vous ne parvenez pas modifier de cette fa on le signal amen l ICON adaptez le avec les potentiom tres Gain de l unit Mid High voir aussi la rubrique Trucs et astuces CONNEXIONS DE SIGNAUX IC 112 LA e Input Raccordez les c bles de signaux Master left right Line out etc de votre table de mixage aux prises Input sym tris es l aide d un c ble XLR sym trique Les broches des prises XLR doivent tre affect es comme suit 1 terre 22 3 E ICON SERIES IC 112 LA Made in Germany SS e e 59 e a lt A THROUGH INPUT SENS Fig 9 Connexions de signaux IC 112 LA 27 ICON SERIES LTS 1 0 e Through Sortie parall le pour transfert du signal Line d entr e e Sub Output
48. circuit same phase CAUTION Never tape over the plug s ground terminal this endangers lives 6 ICON ACCESSORIES e HK AUDIO ICON BVNet Cable Set comprising four CATs RJA5 cables e BV Net Interface Module e HK AUDIO ICON Tilt Unit Designed to hold the ICON mid high unit the tilt unit bolts to the side panels of the subwoofer and mid high unit It offers a choice of 5 10 and 15 angles whereby height adjustable detents automatically set the desired angle e HK AUDIO ICON Dust Cover Set This set comprises four subwoofer and two mid high unit covers Extremely tear resistant water repellant and thickly padded these covers afford lasting protection for the ICON system during transport To learn more about original HK AUDIO accessories talk to your HK AUDIO dealer or visit www hkaudio com 7 TROUBLESHOOTING The Power On LED does not light up when the unit is switched on Check if e the power cord is plugged into the Mains Input e the mains power supply is providing current e the house circuit breaker has tripped The Power On LED lights up red but no sound is issuing from the cabinets Check e the cords connected to the inputs e if the signal sources mixer keyboard CD player etc are on e if the Gain knobs are turned up e the signal carrying cords for damage e the position of the User Settings On Off switch If it is on the controller has loaded the most recent settings from the PC software
49. ctroniques contre l humidit En cas d utilisation en etc sont activ es ext rieur veillez ce que votre syst me soit correctement prot g contre les Les potentiom tres Gain ont ils t tourn s intemp ries Ne jamais renverser sodas bi re ou autres liquides sur les circuits Recherchez tout dommage ventuel sur les c bles de signal lectroniques faute de quoi des courts circuits se produiraient e V rifiez le commutateur User Settings On Off Si celui ci est sur User le logiciel PC charge les derniers r glages dans lesquels la fonction Mute 2 Veillez ce que les fentes d a ration situ es l arri re des appareils soient peut avoir t activ e Si aucun PC n est raccord au syst me placez ce toujours propres et ce que la circulation de l air puisse se faire librement faute commutateur sur Off de quoi l lectronique pourrait subir une surchauffe et tre endommag e TM Peu de basses sortent du subwoofer 3 Les syst mes ICON assurent un son optimal veillez garantir un signal e V rifiez les c bles reliant la douille SUB Out de l unit Mid High IC 112 LA la d entr e optimal Un ronflement est dans la plupart des cas d des c bles douille d entr e du subwoofer IC 118 BA d fectueux des c bles non appropri s ou des signaux d entr e asym triques La restitution musicale semble tre satur e sur la table de mixage V rifiez donc tous les c bles de signal et
50. data bus enables you to monitor the entire system s performance while it is up and running An onboard memory stores data on the power amps operating temperatures and the loudspeakers status for 72 operating hours so can review how the system operated and performed during the most recent events cC Pi BVNED In IC 112 LA BVNet RS485 RJ45 Cable Interface IC 118 BA USB Cable IC 118 BA Laptop Figure 11 How to set up the system and route signals Use a two wire cat 5 cable with standard RJ 45 plug in connectors to connect speaker cabinets to a PC laptop The RS485 interface works with a common bus meaning networked units in the system may be daisy chained to monitor all their operating statuses on one computer There is no need to configure network nodes because every DSP module has a unique address This network transmits control and diagnostic data only and no audio signals so the sound will not drop out A twisted pair category 5 cable serves to transmit data It allows many units to be connected even over greater distances Cat 5 cable s high signal to noise ratio immunity to interference and ability to span great distances has made it one of the most commonly used communication cables You can freely define the system s network topology configuring cabinets in a star or a serial bus or any combination of the two Networks are very easy to configure Simply connect speaker systems using high
51. e unused for long periods of time If this product is to be mounted in an equipment rack rear support should be provided This product should be used only with a cart or stand that is recommended by HK AUDIO Never push objects of any kind into this product through cabinet slots as they may touch dangerous voltage points or short out parts that could result in risk of fire or electric shock Never spill liquid of any kind on the product Do not attempt to service this product yourself as opening or removing covers may expose you to dangerous voltage points or other risks Refer all servicing to qualified service personnel Clean only with dry cloth Do not defeat the safety purpose of the polarized or grounding type plug A polarized plug has two blades with one wider than the other A grounding type plug has two blades and a third grounding prong The wide blade or the third prong are provided for the safety If the provided plug does not fit into your outlet consult an electrician for replacement of the obsolete outlet Place the product always in a way that the mains switch is easily accessible Unplug this product from the wall outlet and refer servicing to qualified ser vice personnel under the following conditions When the power cord or plug is damaged or frayed If liquid has been spilled into the product If the product has been exposed to rain or water If the product does not operate normally when the operating instructions
52. earing protection if continuously exposed to high levels MAINS CONNECTION The unit is designed for continuous operation The set operating voltage must match the local mains supply voltage The unit is connected to the mains via the supplied power unit or power cable Power unit Never use a damaged connection lead Any damage must be recti fied by a competent technician Avoid connection to the mains supply in distributor boxes together with sever al other power consumers The plug socket for the power supply must be positioned near the unit and must be easily accessible PLACE OF INSTALLATION The unit should stand only on a clean horizontal working surface The unit must not be exposed to vibrations during operation Place the product always in a way that the mains switch is easily accessible Keep away from moisture and dust where possible Do not place the unit near water baths wash basins kitchen sinks wet areas swimming pools or damp rooms Do not place objects containing liquid on the unit vases glasses bottles etc Ensure that the unit is well ventilated Any ventilation openings must never be blocked or covered The unit must be positioned at least 20 cm away from walls The unit may only be fitted in a rack if adequate ventilation is ensured and if the manufacturer s installation instructions are followed Keep away from direct sunlight and the immediate vicinity of heating ele ments and radiant heaters or
53. ected components are on The same goes for the mixer and all signal sources connected to it In other words be sure to first switch on any connected keyboards amps effects and the like If you hear any distortion or a saturated signal first check the signal sources and if possible reduce the output signal level there If you are unable to turn down the level of the signal sent to the ICON system at its source adjust the input sensitivity using the mid high units Gain knobs see Tips and Tricks for more on this THE IC 112 LA s CABLE CONNECTIONS e Input Connect the cords routing the signal from your mixer master left right line out or a similar circuit to the balanced inputs using a balanced cord equipped with XLR connectors Ensure XLR connectors are wired as follows 1 ground 2 EI ICON SERIES AUDIO IC 112 LA Made in Germany 10 en LJ LJ H6 e 2 a lt lt d INPUT SENS THROUGH Fig 9 The ICON mid high unit s control features ICON SERIES LTS 1 0 e Through This parallel output serves to forward the incoming line signal e Sub Output This output sends the low frequency signal from the IC 112 LA mid high unit to the ICON IC 118 BA Sub via an XLR cable Ensure XLR connectors are wired as follows 1 ground 2 3 e BVNet In Link Connect the BVNet interface s output to the first mid high unit s In port Then connect the Link port to the next mid high unit s In port
54. eil nous conseillons l utilisateur la lecture des indications de s curit contenues dans le mode d emploi L appareil est conforme la classification mise terre de protection e SURETE FIABILITE ET EFFICACITE DE L APPAREIL NE SONT GARANTIS PAR HK AUDIO QUE SI Montage extension nouveau r glage modification ou r paration sont effectu s par HK AUDIO ou par toute personne autoris e par HK AUDIO L installation lectrique de la pi amp ce concern e correspond aux normes IEC ANSI L utilisation de l appareil suit le mode d emploi AVERTISSEMENT moins que cela ne soit manuellement possible tout enl vement ou ouvertu re du boitier peut entrainer la mise au jour de pieces sous tension e Si l ouverture de l appareil est n cessaire celui ci doit tre coup de chaque source de courant Ceci est prendre en consid ration avant tout ajustement entretien r paration ou changement de pieces e Ajustement entretien ou r paration sur l appareil ouvert et sous tension ne peuvent tre ffectu s que par un sp cialiste autoris par le fabricant selon VBG4 Le sp cialiste tant conscient des dangers li s ce genre de r paration Les sorties de baffles qui portent le signe IEC 417 5036 fig 1 voir en bas peuvent tre sous tension dangereuse Avant de brancher l appareil utiliser uniquement le c ble de raccordement conseill par le fabricant pour raccor der les baffles Tou
55. el aparato a causa de un rayo y golpes de tensi n en la red de corriente alterna Figura 1 W Figura 2 ICON SERIES LTS 1 0 WELCOME TO THE HK AUDIO FAMILY Thank you for choosing an HK AUDIO product ICON LTS Long Throw System is a digitally controlled horn loaded active PA that sets new standards for performance and digital signal management capability Our engineers designed ICON LTS mainly for use in ground stacked configurations at events where conditions or budget constraints prevent you from flying a PA It pairs easy intuitive handling with true articulate response and considerable sound pressure ICON LTS is a self contained active system engineered to deliver excellent sound The horn driven mid high range unit which we ll mid high unit for short features an onboard digital controller that serves as the stack s control center Two band pass subwoofers provide the low end kick State of the art Class D power amp technology delivers the reach and range to throw these signals across great distances at remarkable sound pressure levels Controller software that runs on PCs lets you monitor key performance parameters such as levels power amp temperature and impedance An eight band parametric EQ a two band shelving EQ a high low pass filter as well as Gain Delay Phase and Mute controls enable you to tweak settings and adapt the system to suit the venue ICON LTS ability to satisfy the diverse
56. el with 12 18 and 24 dB each You can copy and paste individual values only 4 Delay Variable in time 0 0116 ms to 201 ms and distance metric units 3 97 mm to 69 m imperial units 0 01 ft to 226 ft 5 Status Indicates the current operating status Driver Indicates speaker impedance green ok red the impedance has changed Note A permanent change in impedance may indicate a defective speaker Amplifier Clip Indicates the amplifier is clipping 6 Gain Indicators Panel for the signal level LIM A and B boxes show the status of the DSP module s software limiters 7 Gain Knob This control adjusts levels and the display panel shows the knob setting DEVICE PANEL PROPERTIES OPTIONS Monet Desc Past Heb murem Figure 14 Device Panel properties options 1 Speakers Properties These are the device speaker and filter designations 2 Logs These logs track the temperature and register how often Protect mode was initiated over a 72 hour period that is the last 72 hours of operation and not the past three days They let you review your system s performance after the event You can read these data from the clipboard 3 Maintenance This is a duty cycle counter that can t be reset In other words it tallies how often the device was switched on as well as how often its Protect mode engaged say because individual power amp modules were overloaded or the operating tempera
57. en it is connected to the IC 112 LA THE IC 118 BA s CABLE CONNECTIONS e Input Use a balanced XLR cord to connect the IC 112 LA mid high unit s Sub Out port to this balanced input and route the signal from the ICON controller to the subwoofer Ensure XLR connectors are wired as follows 1 ground 2 3 The IC 118 BA s input sensitivity is 4 dBu Heads up Never patch the mixer s line or master signal directly into the subwoofer s Input This bypasses the system s controller crossover equalization and protection circuits risking serious damage to the subwoofer Read chapter 2 Setup and Cable Connections for more on this e Through This parallel output serves to forward the incoming subwoofer signal to another IC 118 BA using an XLR cord Ensure XLR connectors are wired as follows 1 ground 2 3 THE IC 118 BA s LED INDICATORS e Limit LED This LED indicates the Class D power amps peak limiter has engaged to attenuate a maximum output voltage excursion or put simply a clipping signal e Signal LED This LED lights up when the unit detects an incoming signal with 56 dBU e Power On LED This LED lights up when a mains power supply is connected EI ICON SERIES AUDIO IC 118 BA Made in Germany Fig 10 The ICON IC 118 BA s control features Temp Limit This LED lights up when one of the three integrated sensors detects that electronic components have reached critical temper
58. er t nicht auf einen instabilen Wagen St nder Dreifuk Untersatz oder Tisch stellen Wenn das Ger t herunterf llt kann es Personen sch den verursachen und selbst besch digt werden Verwenden Sie das Ger t nur mit einem vom Hersteller empfohlenen oder zusammen mit dem Ger t verkauften Wagen Rack St nder Dreifu oder Untersatz Bei der Aufstellung des Ger tes m ssen die Anweisungen des Herstellers befolgt und muss das vom Hersteller empfohlene Aufstellzubeh r verwendet werden Eine Kom bination aus Ger t und Gestell muss vorsichtigt bewegt werden Pl tzliches Anhalten berm ige Kraftanwendung und ungleichm ige B den k nnen das Umkippen der Kombination aus Ger t und Gestell bewirken Zusatzvorrichtungen Verwenden Sie niemals Zusatzvorrichtungen die nicht vom Hersteller empfohlen wurden weil dadurch Unf lle verursacht werden k nnen Zum Schutz des Ger tes bei Gewitter oder wenn es l ngere Zeit nicht beauf sichtigt oder benutzt wird sollte der Netzstecker gezogen werden Dies verhindert Sch den am Ger t aufgrund von Blitzschlag und Spannungs st en im Wechselstromnetz Abb M Abb 2 CAUTION CONSEILS DE SECURITE IMPORTANTS Priere de lire avant l emploi et a conserver pour utilisation ulterieure L appareil a t con u par HK AUDIO selon la norme IEC 60065 et a quitt l entreprise dans un tat irr prochable Afin de conserver cet tat et d assurer un fonctionnement sans danger de l appar
59. er Hub der Ausgangsspannung e Signal LED Diese LED leuchtet wenn ein Eingangssignal von 56 dBU anliegt e Power ON LED Diese LED leuchtet wenn eine entsprechende Netzverbindung besteht e Temp Limit Diese LED Leuchtet wenn die Elektronik an einem der drei Temperatursensoren einen bestimmten Wert erreicht hat Die Endstufe regelt dann 6 dB zur ck bis die Temperatur wieder im normalen Betriebsbereich arbeitet LED erlischt e Amp Diese LED leuchtet beim Einschalten w hrend der Initialisierung der Endstufe ca 5 Sekunden und erlischt dann dauerhaft zeigt den Mute Zustand zum Schutz des Ger tes an z B Fehler im Amp Servicefall w hrend des Betriebs wenn im System ein Fehler auftritt z B Vollaussteuerung bei niederohmigen Lautsprechern Ist die Leistung reduziert erlischt die LED wieder e Wink LED Diese gelbe LED befindet sich im Frontgitter der Mid High Unit und blinkt beim Anw hlen des DSP Moduls durch die PodWare Dr cken des Buttons Locating mehrmals auf 3 2 ICON IC 118 BA BEDIENELEMENTE IC 118 BA e Phase Mit diesem Schalter legen Sie die Polarit t des IC 118 BA fest o die Polarit t des IC 118 BA ist positiv in phase 180 die Polarit t des IC 118 BA ist negativ out of phase In Verbindung mit IC 112 LA ist die Polarit t des IC 118 BA positiv in phase SIGNALANSCHL SSE IC 118 e Input Schlie en Sie den vom ICON Controller kommenden S
60. from the PC software to the first subwoofer The first subwoofer s Through port forwards these signals to the second subwoofer Heads up Be sure to connect cords and route signal in the right sequence Never feed the signal from the mixing console straight to the subwoofer This circumvents the controllers settings and endangers your system Connect audio signal sources to the IC 112 LA mid high unit s Input only IC 112 LA Line In 4 dB o Of In Throu System Guard Sub Out BVNet BVNES Mid High IC 118 BA System Guard In Throu IC 118 BA Audio System Guard Data BVNet Figure 4 Signal routing diagram for an ICON LTS stack 2 2 TwiN ICON LTS A twin ICON LTS consists of two IC 112 LA mid high units and four IC 118 BA subwoofers on each side Use the first mid high unit s Through port to forward the mixing console s signal to the second stack on the same side of the PA Use a balanced XLR cord to route the signal to each stack s subwoofers from that stack s mid high unit s Sub Out port Ensure XLR connectors are wired as follows 1 ground 2 3 IC 112 LA dm o t In Throu System Guard Sub Out BVNet IC 118 BA System Guard e In Throu Out IC 118 BA System Guard o 0 In Throu In Out O Figure 5 Signal routing diagram for a twin ICON LTS Figure 5 See below Setup Be sure t
61. ge Gewindeschrauben Danach entfernen sie die beiden Mio Einschlagmuttern aus der IC 112 LA Mid High Unit Befestigen Sie die beiden Stellschrauben C an der Mid High Unit so dass beide Schrauben innerhalb des gro en Auschnitts der Tilt Unit D liegen Durch Anheben und Einh ngen in die entsprechenden Winkelpositionen der Mid High Unit kann jetzt leicht die gew nschte Neigung 5 10 15 eingestellt werden kann 118 BA Abbildung 8 Montage und Verwendung ICON Tilt Unit 3 ANSCHL SSE UND BEDIENELEMENTE 3 1ICON IC 112 LA BEDIENELEMENTE IC 112 LA e User Settings On Off Mit diesem Schalter wird der Arbeitsmodus des Systems festgelegt User Settings Off nutzt den Controller mit seiner Werkseinstellung In der Konfiguration User Settings On greift der Controller auf die letzten Einstellungen der zuvor erstellten Setups mit der PodWare zur ck Hinweis Stellen Sie die Schalter vor Inbetriebnahme des Systems auf die gew nschte Position Achten Sie bei der Einstellung des Systems Gain EQ Delay mit dem BVNet Interface und der PodWare an Ihrem Laptop darauf dass alle Schalter Mid High Unit auf User Settings On eingestellt sind Das Auslesen von Betriebsdaten ist in beiden Schalterstellungen m glich e Input Sensitivity Zur Anpassung der Eingangsempfindlichkeit an das anliegende Eingangssignal stehen vier Grundein stellungen zur Verf gung 16 dBu 4 dBu o dBu und 20
62. gsskizze ICON LTS System Stach 16 Abb 5 Anschluss Schema doppeltes ICON LTS System 16 Abb 6 Aufstellwinkel zweier ICON Stach 16 Abb 7 ICON IC 112 LA mit Aeroquip Schienen eene 17 Abb 8 Montage und Verwendung ICON Tilt Unit sse 17 Abb 9 ICON Mid High Unit Bedienelemente see 17 Abb 10 ICON IC 118 BA Bedienelemente seen 18 Abb 11 Systemaufbau Verkabelungsskizze EEN 19 Abb 12 Grundfunktionen der PodWare EEN 20 Abb 13 Device Panel EQ Delais 20 Abb 14 Devise Panel properties Options sese 21 EINZIGARTIGE FEATURES 1 ICON 5 1 2 IC 118 BA BANDPASS F R BESTE PERFORMANCE KOMPONENTEN SUBWOOFER Se E 1 1 IC 112 LA HORNGELADENE Digital Amping der neusten Generation f r noch mehr Effizienz und Dynamik einer extrem hohen Effizienz von ber 90 sind Class D Digital Endstufen wesentlich kleiner leichter und kompakter als herk mmliche Endstufen Die geringere thermische Belastung der Bauteile erh ht die hee Zuverlassigkeit Die wesentlich schnellere AN IC 112 LA Anstiegszeit slew rate und der h here D mpfungsfaktor werden in einer deutlich schnelleren pr ziseren Ansprache der Systeme h rbar DR Gees Remote Software PodWare BVNet zur Bedienung und berwachung von ICON Komponenten Abbildung 1 IC 112 LA Im User Mode kann die Lautsprecherinstall
63. historique de l volution de la temp rature et le nombre Pour de plus amples informations sur les accessoires d origine HK AUDIO de modes Protect d clench s sur une p riode de 72 heures Remarque Ces contactez votre revendeur HK AUDIO ou visitez le site Internet www hkaudio 72 heures ne sont pas des p riodes de fonctionnement com Vous pouvez ainsi contr ler le comportement du syst me m me apr s votre concert Les donn es peuvent tre lues par Clipboard 7 D PISTAGE DES PANNES 3 Maintenance Comptabilise les cycles de mise en service ne peut tre remis z ro et indique si l appareil est pass en mode Protect p ex en raison La DEL Power On ne s allume pas rouge lors de la mise sous tension d une surcharge des diff rents modules des tages de puissance ou d une tem p rature de fonctionnement trop lev e Vous trouverez d autres informations sur l utilisation du logiciel dans le CD fourni avec le logiciel d installation e Assurez vous que le cordon secteur est raccord la prise d entr e Mains e Assurez vous que la prise secteur est bien sous tension e V rifiez que les fusibles du b timent n ont pas saut La DEL Power On s allume rouge mais aucun son ne sort des enceintes e V rifiez les c bles de raccordement que vous avez branch s sur les connexions 5 TRUCS ET ASTUCES d entr e e Assurez vous que les sources de signal table de mixage clavier lecteur de CD 1 Prot gez les circuits le
64. ie Steckdose f r die Stromversorgung muss nahe am Ger t angebracht und leicht zug nglich sein AUFSTELLUNGSORT Das Ger t sollte nur auf einer sauberen waagerechten Arbeitsfl che stehen Das Ger t darf w hrend des Betriebs keinen Ersch tterungen ausgesetzt sein Feuchtigkeit und Staub sind nach M glichkeit fernzuhalten Das Ger t muss immer so aufgestellt werden dass der Netzschalter frei zu g nglich ist Das Ger t darf nicht in der N he von Wasser Badewanne Waschbecken K chensp le Nassraum Swimmingpool oder feuchten R umen betrieben werden Keine mit Fl ssigkeit gef llten Gegenst nde Vase Gl ser Flaschen etc auf das Ger t stellen Sorgen Sie f r ausreichende Bel ftung der Ger te Eventuelle Ventilations ffnungen d rfen niemals blockiert oder abgedeckt werden Das Ger t muss mindestens 20 cm von W nden entfernt aufgestellt werden Das Ger t darf nur dann in ein Rack eingebaut werden wenn f r ausreichende Ventilation gesorgt ist und die Einbauanweisungen des Her stellers eingehalten werden Vermeiden Sie direkte Sonneneinstrahlung sowie die unmittelbare N he von Heizk rpern und Heizstrahlern oder hnlicher Ger te Wenn das Ger t pl tzlich von einem kalten an einen warmen Ort gebracht wird kann sich im Ger teinnern Kondensfeuchtigkeit bilden Dies ist insbe sondere bei R hrenger ten zu beachten Vor dem Einschalten solange warten bis das Ger t Raumtemperatur angenommen hat Zubeh r Das G
65. ignalweg Subwoofer Output des IC 112 LA Mid High Unit an die symmetrierte Subwoofer Input Buchse mit einem symmetrischen XLR Kabel an Die Belegung der XLR Stecker muss dabei wie folgt sein 12 Ground 2 3 Die Eingangsempfindlichkeit der IC 118 BA betr gt 4 dBu Wichtig SchlieRen Sie keinesfalls die Line bzw Master Signalwege des Mischpultes direkt an den Subwoofer Input an dieser w rde dann ohne Controller also ohne Frequenzweiche Entzerrung und Systemschutz angesteuert werden und k nnte ernsten Schaden nehmen Lesen Sie hierzu auch das Kapitel 2 Aufstellung und Verkabelung e Through Anschluss Paralleler Ausgang zur Weiterleitung des Subwoofer Signals an einen weiteren IC 118 BA mittels XLR Kabel Die Belegung der XLR Stecker muss dabei wie folgt sein 12 Ground 2 3 KONTROLLLEUCHTEN 118 BA e Limit LED Diese LED zeigt den Einsatz der Peaklimiter der Class D Endstufen an maximaler Hub der Aus gangsspannung e Signal LED Diese LED leuchtet wenn ein Eingangssignal von 56 dBU anliegt e Power On LED Diese LED leuchtet wenn eine entsprechende Netzverbindung besteht E ICON SERIES AUDIO IC 118 BA Made in Germany Abbildung 10 ICON IC 118 BA Bedienelemente e Temp Limit Diese LED leuchtet wenn die Elektronik an einem der drei Temperatursensoren einen bestimmten Wert erreicht hat Die Endstufe regelt dann 6 dB zur ck bis die Temperatur wieder im normalen Bet
66. interno si crei della condensa Cid va tenuto in considerazione soprattutto in caso di apparecchi a valvole Attendere che l apparecchio abbia assunto la temperatura ambiente prima di accenderlo Accessori non collocare l apparecchio su carrelli supporti treppiedi superfici o tavoli instabili Se l apparecchio dovesse cadere a terra potrebbe causare danni a terzi o danneggiarsi irreparabilmente Utilizzate per il collocamento dell apparecchio supporti treppiedi e superfici che siano consigliate dal produttore o direttamente comprese nell offerta di vendita Per il colloca mento dell apparecchio attenetevi strettamente alle istruzioni del produttore utilizzando esclusivamente accessori da esso consigliati L apparecchio in combinazione ad un supporto va spostato con molta attenzione Movimenti bruschi o il collocamento su pavimenti non piani possono provo care la caduta dell apparecchio e del suo supporto Accessori supplementari non utilizzate mai accessori supplementari che non siano consigliati dal produttore potendo essere causa di incidenti se utilizzato per diverso tempo si consiglia di staccarne la spina di corrente In questo modo si evitano danni all apparecchio dovuti a colpi di fulmine o ad improvvisi aumenti di tensione nel circuito di corrente alternata Illustrazione 1 W Illustrazione 2 Per proteggere l apparecchio in caso di temporali o nel caso questo non venis ilNDICACIONES DE SEGURIDAD IMPORTANTES jL a
67. ion via le logiciel PC sont transmis depuis l unit Mid High via la douille Sub Out au premier subwoofer et de l au deuxi me subwoofer via la douille Through Remarque importante Veillez l ordre correct du c blage Ne raccordez jamais le signal provenant de la table de mixage directement au subwoofer car vous contourneriez les param tres du con tr leur syst me et feriez courir des risques votre appareil Raccordez uniquement les sources de signal audio l entr e de l unit IC 112 LA Mid High IC 112 LA Line In 4 dB o In Throu System Guard Sub Out BVNet BVNES No To next di IC 118 BA System Guard o In Throu i IC118BA System Guard ind God In Throu Data BVNet Fig 4 Sch ma de c blage du syst me ICON LTS Stack 2 2 SYST ME ICON LTS DOUBLE Un syst me ICON LTS double se compose de deux unit s Mid High IC 112 LA et de quatre subwoofers IC 118 BA par c t Pour envoyer le signal de la table de mixage sur le deuxi me stack ICON d un c t de la sonorisation utilisez la douille Through de la premi re unit Mid High A partir des t tes reliez les subwoofers l unit Mid High via la douille Sub Out Utilisez cet effet un c ble XLR sym trique IC 112 LA dm o t In Throu System Guard Sub Out BVNet IC 118 BA System Guard In Throu IC 118 BA System Guard o 0 In Thro
68. it commander toutes les unit s du syst me et surveiller l tat de fonctionnement Daisy chain Chaque module DSP poss de une adresse propre et non modifiable ce qui supprime pour l utilisateur la n cessit de configurer les noeuds du r seau tant donn que seules les donn es de r glage et de diagnostic syst me du moment sont transmises sur le r seau la restitution audio n est pas interrompue Un c ble CATs est employ pour la transmission des donn es Cette paire torsad e garantit la connexion avec un grand nombre d unit s possibles y compris sur de grandes distances Du fait de son immunit acoustique et des grandes distances de connexion possibles le standard CATs est l un des plus utilis s en technologie de la communication Le syst me permet une topologie de r seau libre ainsi les haut parleurs peuvent tre dispos s en s rie en toile ou dans n importe quelle combinaison des deux configurations Les syst mes de haut parleurs sont reli s par des connecteurs Ethercon compatibles RJ45 de grande qualit d autres composants sont reli s par des c bles CATS avec connecteurs RJ45 Il est ainsi possible de cr er ais ment un r seau Les haut parleurs reconnus dans le r seau poss dent des noms d finis d usine qui peuvent tre modifi s pour une affectation sp cifique l utilisateur La fonction Flash permet de localiser les diff rents appareils lorsque la DEL clignotante l avant de l
69. it DSP Modul wird in der PodWare als Device Panel angezeigt Die Parameter und berwachungsfunktionen k nnen in diesem Device Panel auf zwei verschiedenen Fensterebenen abgelesen editiert und kontrolliert werden 7 Gain Regler zur Pegelanpassung mit Anzeigefeld Darstellung des Regler wertes DEVICE PANEL PROPERTIES OPTIONS Abbildung 14 Devise Panel properties Options 1 Speakers Properties kennzeichnet Ger tenamen Lautsprechernamen und Filternamen 2 Logs gibt die Historie des Temperaturverlaufs und der Anzahl der ausgel sten Protect Modes f r einen Zeitraum von 72 Betriebstunden an Damit k n nen Sie das Systemverhalten auch nach Ihrer Veranstaltung kontrollieren Die Daten k nnen per Clipbord ausgelesen werden 3 Maintenance z hlt Einschaltzyklen hoch kann nicht zur ckgesetzt werden und gibt an ob das Ger t in den Protect Mode wechselte z B wegen berlas tung der einzelnen Amplifier oder zu hoher Betriebstemperatur Weitere Informationen zur Bedienung der Software entnehmen Sie bitte aus der beigef gten CD mit der Installations Software 5 TIPPS UND TRICKS 1 Lassen Sie keine Feuchtigkeit an die Elektronik kommen Achten Sie beim Einsatz im Freien darauf dass Ihr System vor Regen gesch tzt aufgestellt wird Cola Bier oder andere Fl ssigkeiten d rfen nicht an die Elektronik gelangen da dies zu Kurzschl ssen f hren kann 2 Achten Sie darauf dass die L ftungsschlitze auf der R ckseite de
70. ite aus zwei Mid High Units IC 112 LA und vier Subwoofern IC 118 BA Um das Mischpultsignal auf den zweiten ICON Stack einer Beschallungsseite zu leiten benutzen Sie die Through Buchse des ersten Mid High Unit Von den jeweiligen Tops verbinden Sie die jeweiligen Subwoofer ber die Sub Out Abbildung 3 ICON LTS System Das ICON System wird immer von oben nach unten verkabelt siehe Abb 4 IC 112 LA e O Im ICON LTS System sitzt der zentrale System In Throu System Guard controller f r das komplette Stack in der Mid High Sub Out BVNet e Unit IC 112 LA Das f r den Subwoofer gefilterte ENED Basssignal und das Steuersignal zur Bedienung ber die PC Software werden von der Mid High Unit ber die Sub Out Buchse an den ersten Subwoofer und von dort ber die Through Buchse an den zweiten Subwoofer weitergeleitet Wichtiger Hinweis Achten Sie auf die richtige Reihenfolge der Verkabelung Schlie en Sie niemals das vom Mischpult kommende Signal an den Subwoofer direkt an Sie umgehen dann die Einstellungen des Systemcontrollers und gef hrden ihr System Schlie en Sie Audiosignalquellen nur am Input der IC 112 LA Mid High Unit an LLL IC 118 BA System Guard 4 In Throu Q t Out IC 118 BA System Guard Throu O In Out Abbildung 5 Anschluss Schema Doppeltes ICON LTS System Buchse der Mid High Unit Verwenden Sie dazu ein Mikrofonkabel Die Belegung der
71. l fuse Mains voltage range Mains connector 1050 W IC 112 LA 1880 W IC 118 BA 4 5 IC 112 LA 8 1 A IC 118 BA 4 AT 10 AT IC 112 LA 10 AT IC 118 BA 220 V 240 V Neutrik Powercon This is to certify that ICON IC 112 LA ICON IC 118 BA complies with the provisions of the Directive of the Council of the European Communities on the approximation of the laws of the Member States relating to electromagnetic compatibility according to EMC directive 2004 108 EC and low voltage directive 2006 95 EC This declaration of conformity of the European Communities is the result of an examination carried out by the Quality Assurance Depart ment of STAMER GmbH in accordance with Eu ropean Standards EN61000 6 1 EN61000 6 2 and EN 60065 for low voltage SICHER STAMER MUSIKANLAGEN GMBH Magdeburger Str 8 66606 St Wendel Germany Lothar Stamer Dipl Ing St Wen Gi Version 2 0 08 2008 13 ICON IC 112 LA ICON IC 118 BA 1 24 21 12 9 3 0 21 18 W 9 5 Bl 18 15 I 2 15 12 T O 24 21 21 18 18 15 1 15 12 0 05 0 1 0 2 0 5 kHz Max SPL Deg 150 100 50 Directivity horizontal 2D 50 100 150 Grooup Delay Grooup Delay ICON SERIES LTS 1 0 WILLKOMMEN IN DER HK AUDIO FAMILIE Vielen Dank dass Sie sich f r ein HK AUDIO Produkt entschieden haben I
72. lla HK AUDIO solo ed esclusivamente se e Montaggio ampliamento rimessa a punto modifiche e riparazioni vengono eseguite dalla HK AUDIO stessa o da personale da essa autorizzato Gli impianti elettrici nei locali prescelti per l uso dell apparecchio rispondono alle normative stabilite dall ANSI L apparecchio viene utilizzato come indicato nel libretto delle istruzioni per l uso AVVERTIMENTI e In caso di apertura di parti di rivestimento o rimozione di parti dell involucro a meno che non si tratti di pezzi rimovibili semplicemente a mano possono venire alla luce parti dell apparecchio conduttrici di tensione Se l apertura dell apparecchio dovesse risultare necessaria indispensabile staccare precedentemente quest ultimo da tutte le fonti di tensione Rispett are tale misura di prevenzione anche prima di un allineamento di operazioni di manutenzione della messa in esercizio o della sostituzione di componenti all interno dell apparecchio Allineamento operazioni di manutenzione o eventuali riparazioni dell apparecchio in presenza di tensione vanno eseguite esclusivamente da personale specializzato ed autorizzato in grado di eseguire tali operazioni evitandone i rischi connessi Le uscite degli altoparlanti contrassegnate dai caratteri IEC 417 5036 vedi illustrazione 1 a fondo pag possono essere conduttrici di tensione peri colosa con cui evitare il contatto Per questo motivo prima di accendere l apparecchio colleg
73. m the housing and mount the tilt unit using the long fastening bolts B Then remove the two Mio T nuts from the IC 112 LA mid high unit Attach the two set screws C to the mid high unit so both are located within the large opening of the tilt unit D Now simply raise the cab and insert it in the detent that gives you the desired tilt angle 5 10 or 15 IC 118 BA Figure 8 How to mount and adjust the ICON Tilt Unit 3 CONNECTIONS AND CONTROL FEATURES 3 1 ICON IC 112 LA THE IC 112 LA s CONTROL FEATURES e User Settings On Off Use this switch to determine the system s operating mode Disengage it User Settings Off to use the controller s factory settings If you engage it User Settings On the controller will adopt the settings most recently configured in the PodWare application Note Set switches to the desired positions before powering the system up When configuring gain EQ and delay settings remotely via the BVNet interface and the PodWare on your laptop engage all switches on the mid high unit User Settings On The software can read out operating data when the switch is set to either position e Input Sensitivity You have four hardwired options for adjusting the gain to match the input signal level 16 dBu 4 dBu o dBu and 10 dBu The standard setting for ICON systems is 4 dBu Before powering up the system ensure subwoofers are connected via the Sub Out port and all other conn
74. mit der der Treiber und Schutzfunktionen der Endstufel horngeladenen 12 Speaker liefern Die komplette IC 112 LA Mid High Unit entwickelt wurde Er hat Elektronik ist in einer eigenen Kammer am hinteren keine eigene Frequenzweiche und l uft au erhalb Teil des Geh uses untergebracht und von dort ber des ICON Systems ohne jegliche Frequenztrennung das Bedienpanel ansteuerbar Dort befinden sich und Limitierung Vermeiden Sie deshalb auch die Anschl sse und LEDs die den aktuellen unbedingt den Anschluss an ein Audiosignal ohne Betriebsmodus des Systems anzeigen vorgeschalteten Controller integriert in die IC 112 LA Mid High Unit 1 3 TRANSPORT Zum einfachen Transport des Systems steht ein Rollbrett zur Verf gung Verwenden Sie die original HK AUDIO ICON Schutzh llen mit denen Sie Ihr pers nliches System f r den harten On The Road Einsatz r sten Gut gepolstert und gegen N sse gesch tzt werden Sie lange Freude an Ihrem ICON System haben ICON SERIES LTS 1 0 2 AUFSTELLUNG UND IC 112 LA Line In VERKABELUNG 4 dB 2 4 c Sub Out BVNet e 2 1 ICON LTS SvsTEM BVNED Das Standard System ICON LTS besteht aus No PCI 2x IC 112 LA und 4x IC 118 BA To next Mid High IC 118 BA System Guard o In Throu IC 118 BA Audio System Guard Data BVNet Abbildung 4 Verkabelungsskizze ICON LTS System Stack 2 2 DoPPELTES ICON LTS SYSTEM Ein doppeltes ICON LTS System besteht pro Se
75. ng des BVNet Interface mit der BVNet In Buchse der ersten Mid High Unit Verbinden Sie nun die BVNet In der n chsten Mid High Unit ber die BVNet Link Buchse Beim Anschluss weiterer Komponenten mit DSP Modul verfahren Sie nach dem gleichen Muster e Sub Link In Buchse Internal System Guard Durch Verbinden der IC 118 BA Subwoofer ber die Internal Link Buchsen zur Mid High Unit k nnen Sie das gesamte System in seiner Funktion berwachen Verbinden Sie dazu die Subwoofer ber ein Standard Ethernet Kabel RJ45 mit der Mid High Unit e Mains Input Powercon Durch Drehen des Powercon Steckers bis zum Anschlagpunkt Stecker rastet ein wird der Lautsprecher eingeschaltet Verbinden Sie diese Anschlussbuchse mittels des mitgelieferten Powercon Stromkabels mit der Netzsteckdose Achtung Achten Sie auf die jeweils g ltigen Spannungen Der Anschluss an eine falsche Netzspannung kann die Elektronik des ICON Systems zerst ren Wichtig An einer Phase d rfen maximal ein Strom von 16 A bzw eine Leistung von 3600 W bei 230 Volt entnommen werden d h Sie k nnen maximal ein ICON LTS Stack daran betreiben Schalten Sie immer die ICON Komponenten nacheinander ein um die Einschaltstr me m glichst gering zu halten Andernfalls k nnte durch den hohen Gesamt Einschaltstrom die Haussicherung herausspringen KONTROLLLEUCHTEN IC 112 LA e Limit LED Diese LED zeigt den Einsatz der Peaklimiter der Class D Endstufen an maximal
76. nse antes de utilizar el aparato y guardense para so uso posterior El aparato ha sido producido por HK AUDIO seg n el IEC 60065 y sali de la f brica en un estado t cnicamente perfecto Para conservar este estado y asegurar un funcionamiento sin peligros el usuario debe tener en cuenta las indicaciones y advertencias contenidas en las instrucciones de manejo El aparato corresponde a la clase de protecci n toma de tierra protegida LA SEGURIDAD LA FIABILIDAD Y EL RENDIMIENTO DEL APARATO SOLO ESTAN GARANTIZADOS POR HK AUDIO CUANDO el montaje la ampliaci n el reajuste los cambios o las reparaciones se realicen por HK AUDIO o por personas autorizadas para HK AUDIO la instalaci n el ctrica del recinto en cuesti n corresponda a los requisitos de la determinaci n del IEC ANSI el aparato se use de acuerdo con las indicaciones de uso ADVERTENCIA Si se destapan protecciones o se retiran piezas de la carcasa exceptuando si se puede hacer manualmente se pueden dejar piezas al descubierto que sean conductoras de tensi n Sies necesario abrir el aparato ste tiene que estar aislado de todas las fuentes de alimentaci n Esto se debe tener en cuenta antes del ajuste de un entretenimiento de una reparaci n y de una sustituci n de las piezas e Un ajuste un entretenimiento o una reparaci n el aparato abierto y bajo tensi n s lo puede ser llevado a cabo por un especialista autorizado por el productor
77. o align the two stacks correctly when configuring the ICON systems in twin array Otherwise undesirable frequency cancellations or phasing effects may degrade the system s frequency response Feel free to set subwoofers side by side that is with the sidewalls touching Figure 6 Tilt angle for two ICON stacks IC 112 LA e Throu Sub Out System Guard BVNet O IC 118 BA System Guard o Throu Out IC 118 System Guard o 0 In Throu In Out O 2 3 FLYING ICON IC 112 LA MiD HIGH UNirs Please use optionally available Aeroquip studs or stud starter cables to fly mid high units ok IC 112 Figure 7 ICON IC 112 LA with Aeroquip rails Note For reason of safety use tested and certified load securing devices only for example half coup lers clamps safety cables and so forth Ensure all rigging points are rated to handle the load An ICON LT 112 weighs 49 9 kg 110 lbs without Dolly 2 4 USING THE ICON TiLT UNIT The ICON Tilt unit lets you aim the ground stacked ICON IC 112 LA mid high unit towards the audience area accurately and safely You can tilt the mid high unit by 5 10 or 15 to suit the venue minimize troublesome ceiling reflections and direct more sound pressure towards the audience area First attach the ICON tilt unit s brackets A to the top IC 118 BA subwoofer To do this remove the Mio T nuts fro
78. operties Options essere 11 DES CARACT RISTIQUES EXCLUSIVES POUR DES PERFORMANCES OPTIMALES Digital Amping de la derni re g n ration pour une efficacit et un dynamisme encore accrus D une efficacit extr mement lev e sup rieure 9096 les tages de puissance num rique de Classe D se montrent nettement plus petits l gers et compacts que des tages de puissance classiques La sollicitation thermique r duite de leurs composants accro t en outre leur fiabilit Quant leur temps de mont e slew rate consid rablement plus court et leur facteur d att nuation sup rieur ils se traduisent par une r ponse nettement plus rapide et plus pr cise des syst mes Logiciel distance PodWare BVNet pour la commande et la surveillance des composants ICON En mode utilisateur le syst me ICON LTS peut tre command distance l aide de l interface BVNet et d un ordinateur portable Le logiciel pour PC PodWare et l interface BVNet entre ordinateur portable et syst me tous deux fournis permettent le traitement manuel des r glages du son avec tous les param tres essentiels comme les galisations param trique et tag re Shelving le Delay l inversion de phase et le Gain Le syst me peut ainsi tre adapt au mieux aux conditions locales En outre il est possible de lire toutes les fonctions de surveillance tant en ligne pendant la manifestation qu ult rieurement
79. par entr e directe des valeurs Il n est pas possible d tablir un lien direct entre les appareils mais les r glages EQ peuvent tre copi s par un Copy and Paste 2 Filtre Low Shelf High Shelf Param tres r glables freq 10 Hz 25 6 KHz pente 6 dB 12 dB Gain 15 dB 15 dB Les valeurs des diff rents appareils peuvent ici uniquement tre reprises l aide d un Copy and Paste 3 Filtre passe bas passe haut Param tres r glables fr q 20 2 Hz 25 6 KHz type de filtre ver ordre Bessel Butterworth Linkwitz Riley Bessel 12 18 et 24 dB Ici la fonction Copy and Paste est uniquement possible pour les valeurs prises individuellement 4 Delay R glable en temps 0 0116 ms 201 ms et en distance m trique 3 97 mm 69 m et en pouces 0 01 ft 226 ft 5 Etat Indique l tat de fonctionnement actuel Driver indique l imp dance correcte des haut parleurs vert ok rouge modification Remarque La modification durable de l imp dance peut aussi signaler un haut parleur d fectueux Amplifier Clip Indique une saturation de l ampli 6 Affichage Gain e Zone d entr e indique le niveau d entr e e LIM A et B indique le limiteur du logiciel sur le module DSP 7 Potentiom tre Gain Pour modifier le niveau avec la zone d affichage affi chage de la valeur du potentiom tre 31 DEVICE PANEL PROPERTIES OPTIONS qu il ne doive pas tre modifi par
80. r aufgebaut um ein Update mit der Erweiterung dotnetfx exe durchzuf hren Das muss unbedingt erfolgen sonst kann PodWare nicht benutzt werden Sie k nnen diese Datei ca 22 MB auch offline zuvor installieren Erforderliche Hardware e Windows Rechner XP Vista mit Ethernet Schnittstelle CATS Kabel e BVNet Modul Interface INSTALLATION UND KONFIGURATION DER PODWARE Installation PodWare e berpr fen Sie dass alle Kabel angeschlossen sind und das System eingeschaltet ist e Starten Sie die Setup exe und folgen Sie den Anweisungen auf dem Bildschirm Die Software wird nun automatisch installiert Starten Sie den Rechner neu auch wenn Sie dazu nicht aufgefordert werden COM Port Auswahl ffnen Sie das Start Men von Windows XP und w hlen Sie den Eintrag PodWare ffnen Sie im Men den Eintrag Network Com Port und w hlen sie den entsprechenden Com Port aus an dem Sie das serielle Kabel zum BVNet Interface angeschlossen haben Tipp Im Windows Ger temanager k nnen Sie sich ber die Nummer des Com Ports erkundigen 19 ICON SERIES LTS 1 0 gt Start gt Systemsteuerung gt System gt Hardware gt Ger temanager gt Anschl sse Device PANEL EQ DeLay Com und LPT Hier k nnen Sie nochmals priifen ob ein USB to Serial Adapter TUI richtig installiert ist Sec TI ffnen Sie das Start Men von Windows XP und w hlen Sie den Eintrag Bc PodWare
81. r Ger te immer frei von Schmutz sind und die Luftzirkulation gew hrleistet ist Ansonsten kann die Elektronik berhitzen und Schaden nehmen 3 ICON Systeme sorgen f r optimalen Sound sorgen Sie f r das optimale Eingangssignal Brummen ist in den meisten F llen das Resultat defekter Kabel falscher Kabel oder unsymmetrischer Eingangssignale am Mischpult berpr fen Sie alle Signal und Netzkabel 4 Verhindern Sie Verzerrungen Verzerrungen sind nicht nur unangenehm f r die Ohren der Zuh rer sie sind auch gef hrlich f r Ihre Anlage Achten Sie darauf dass alle direkt und indirekt an ICON angeschlossenen Komponenten ber gen gend Leistung verf gen und niemals Verzerrungen produzieren weil sie am Limit betrieben werden Sorgen Sie f r ein sauberes Signal das nicht durch den Einsatz des Gain Reglers beeinflusst werden muss 5 Vermeiden Sie Brummschleifen Ist beispielsweise das Mischpult ber das Netzkabel geerdet und h ngt nicht auf dem gleichen Stromkreis wie ICON so kann es zu einer sogenannten Brummschleife kommen Schlie en Sie deshalb stets das ICON System und das Mischpult an den gleichen Stromkreis gleiche Phase an ACHTUNG Nie die Erdung am Netzstecker abkleben Lebensgefahr 6 ZUBEHOR ICON e HK AUDIO ICON Kabelsatz BVNet bestehend aus vier CAT5 RJ45 Kabeln e BV Net Interface Modul e HK AUDIO ICON Tilt Unit Schr gsteller f r die ICON Mid High Unit Die Tilt Unit wird seitlich an Subwoofer und Mid
82. requirements of so many different gigs big name top 40 cover bands open air concerts in the city dates in clubs tents at road shows and mobile dance events make it the system of choice for rental companies and professional bands Your HK AUDIO team wishes you every success with your ICON LTS TABLE OF CONTENTS 1 ICON SYSTEM COMPONENTS 5 1 2 IC 112 1 The Horn loaded Mid High Unit sss 5 IC 18 The Band pass Subwoofer 5 na 5 2 SETUP AND CABLE 5 6 CS Oe ei MA 6 22 1 amp Sense ct nn en 6 2 3 Flying ICON IC 112 LA Mid High Unit 7 10 E E N NU Pen 7 3 CONNECTIONS AND CONTROL FEATURES 7 31 ICON IC 112 LA Control Features Cable Connections and LED Indicators 7 32 ICON IC 118 BA Control Features Cable Connections and LED Indicators 8 4 PODWARE REMOTE CONTROL BVNET INTERFACE 9 43 Reguired COMPONEN cod 9 T 9 4 3 Installation and Firmware Update 9 4 4 Howto Handle the Software is 10 3 FIPSAND TRICKS nun 11 6 CON ACCESSORIES circa aan 11 7 FROUBLESHOOTING sun nun 11 8 gt tousse 12 1612 c 12 CONTABA c 12 Table of figures ASAP m
83. riebsbereich ist LED erlischt e Amp Diese LED leuchtet beim Einschalten w hrend der Initialisierung der Endstufe ca 5 Sek und erlischt dann dauerhaft zeigt den Mute Zustand zum Schutz des Ger tes z B Fehler im Amp Achtung Servicefall leuchtet wahrend des Betriebs wenn im System ein Fehler auftritt z B Vollaussteuerung bei niederohmigen Lautsprechern Ist die Leistung reduziert erlischt die LED wieder 4 REMOTE SOFTWARE POD WARE BVNET INTERFACE e Zur Fernbedienung und berwachung Ihres Systems Neben der Werkseinstellung ist es m glich das System ber eine Netzwerkverbindung mit einen PC fernzusteuern User Settings Die mitgelieferte PC Software PodWare und das zwischen Laptop und System geschaltete BVNet Interface erm glichen die manuelle Bearbeitung der Sound Einstellungen mit allen wichtigen Parametern zur Anpassung des Systems an die rtlichen Gegebenheiten 4 1 ERFORDERLICHE NENTEN Dazu ben tigen Sie PC oder Laptop mit dem Betriebssystem WIN XP oder Vista BVNet Modul Interface 1x USB Kabel 6x CAT5 Kabel Hinweis Der Schalter User Settings On Off am IC 112 LA muss entsprechend der Nutzung mit PC Software auf On eingestellt sein 4 2 BERWACHUNG Eine interne Datenleitung bietet die M glichkeit die Funktion des kompletten Systems w hrend des Betriebs zu berwachen Daten ber die Betriebstemperatur der Endstufen und ber
84. rom all power sources Please take this into account before carrying out adjustments main tenance repairs and before replacing parts The appliance can only be insulated from all power sources if the mains connection is unplugged Adjustment maintenance and repairs carried out when the unit has been opened and is still live may only be performed by specialist personnel who are authorized by the manufacturer in accordance with VBG 4 and who are awa re of the associated hazards Loudspeaker outputs which have the IEC 417 5036 symbol Diagram 1 below can carry voltages which are hazardous if they are made contact with Before the unit is switched on the loudspeaker should therefore only be connected using the lead recommended by the manufacturer Where possible all plugs on connection cables must be screwed or locked onto the casing Replace fuses only with 1EC127 type and specified ratings It is not permitted to use repaired fuses or to short circuit the fuse holder Never interrupt the protective conductor connection Surfaces which are equipped with the HOT mark Diagram 2 below rear panels or covers with cooling slits cooling bodies and their covers as well as tubes and their covers are purposely designed to dissipate high temperatures and should therefore not be touched High loudspeaker levels can cause permanent hearing damage You should therefore avoid the direct vicinity of loudspeakers operating at high levels Wear h
85. s la tension et le lieu de la manifestation Avant la mise en service du syst me vous devez donc imp rativement v rifier la puissance disponible sur le r seau Branchez toujours les composants ICON l un apr s l autre afin de r duire au maximum les courants d enclenchement Une intensit trop lev e risquerait en effet de faire sauter les fusibles T MOINS DE CONTR LE IC 112 LA e DEL Limit Cette DEL indique l utilisation des limiteurs de cr te des tages de puissance de la classe D augmentation maximale de la tension de sortie e DEL Signal Cette DEL s allume en cas de signal d entr e 56 dBU e DEL Power ON Cette DEL s allume en cas de branchement au r seau e DEL Temp Limit Cette DEL s allume lorsque l lectronique au niveau de l un des trois capteurs int gr s cet effet atteint une temp rature critique Dans ce cas l tage de puissance redescend de 6 dB jusqu ce que la temp rature soit nouveau situ e dans une plage normale la DEL s teint alors e DEL Amp Cette DEL s allume la mise sous tension pendant l initialisation de l tage de puissance env 5 secondes puis s teint durablement indique l tat Mute pour la protection de l appareil p ex d faillance dans l ampli cas de maintenance pendant le fonctionnement en cas d erreur dans le syst me p ex r glage maximum pour les amplis faible valeur ohmique La DEL s teint d s que la pui
86. schalten des Ger tes Verbindung nur mit dem vom Hersteller empfohlenen Anschlusskabel zum Lautsprecher herstellen Alle Stecker an Verbindungskabeln m ssen mit dem Geh use verschraubt oder verriegelt sein sofern m glich Es d rfen nur Sicherungen vom Typ IEC 127 und der angegebenen Nenn stromst rke verwendet werden Eine Verwendung von geflickten Sicherungen oder KurzschlieRen des Halters ist unzul ssig Niemals die Schutzleiterverbindung unterbrechen Oberfl chen die mit dem HOT Zeichen Abb 2 s unten versehen sind R ckw nde oder Abdeckungen mit K hlschlitzen K hlk rper und deren Ab deckungen sowie R hren und deren Abdeckungen k nnen im Betrieb erh hte Temperaturen annehmen und sollten deshalb nicht ber hrt werden Hohe Lautst rkepegel k nnen dauernde Geh rsch den verursachen Vermeiden Sie deshalb die direkte N he von Lautsprechern die mit hohen Pegeln betrieben werden Verwenden Sie einen Geh rschutz bei dauernder Einwirkung hoher Pegel NETZANSCHLUSS Das Ger t ist f r Dauerbetrieb ausgelegt Die eingestellte Betriebsspannung muss mit der rtlichen Netzspannung bereinstimmen Der Anschluss an das Stromnetz erfolgt mit dem mitgelieferten Netzteil oder Netzkabel Netzteil Eine besch digte Anschlussleitung kann nicht ersetzt werden Das Netzteil darf nicht mehr betrieben werden Vermeiden Sie einen Anschluss an das Stromnetz in Verteilerdosen zusam men mit vielen anderen Stromverbrauchern D
87. se han cumplido las indicaciones de montaje del productor Evite los rayos del sol directos as como la proximidad a radiadores electro radiadores o aparatos similares Si el aparato pasa repentinamente de un lugar fr o a otro caliente se puede condensar humedad en su interior Esto se debe tener en cuenta sobretodo en los aparatos con v lvulas electr nicas Antes de poner en marcha el apara to se debe esperar hasta que ste haya adquirido la temperatura ambiental Accesorios el aparato no se puede colocar encima de carros estantes tr podes soportes o mesas inestables Si el aparato se cae puede causar da os personales y se puede estropear Coloque el aparato s lo en un carro rack estante tr pode o soporte recomendado por el productor o que se le haya vendido junto con el aparato En la instalaci n se deben seguir las indicaciones del productor as como utilizar los accesorios recomendados por el mismo para colocarlo encima El conjunto del aparato con el pedestal se debe mover con mucho cuidado Un paro brusco la aplicaci n de una fuerza desmesurada o un suelo irregular puede ocasionar la caida de todo el conjunto Piezas adicionales no utilice nunca piezas adicionales que no est n recomen dadas por el productor ya que se podr an provocar accidentes Para protejer el aparato de una tormenta o si no se supervisa ni utiliza durante alg n tiempo se deber a desconectar la clavija de la red As se evitan da os en
88. ssance diminue e DEL Wink Cette DEL jaune se trouve sur la grille situ e l avant de l unit Mid High et clignote plusieurs fois lorsque le PodWare se connecte au module DSP bouton Locating 3 2 ICON IC 118 BA COMMANDES IC 118 BA e Phase Ce commutateur permet de fixer la polarit de 1 118 BA la polarit est positive in phase 180 la polarit est n gative out of phase En cas de branchement sur l IC 112 LA la polarit est positive in phase CONNEXION DE SIGNAUX IC 118 BA e Input A l aide d un c ble XLR positif raccordez le trajet de signal provenant du contr leur de l ICON sortie subwoofer de l unit Mid High IC 112 LA la prise Subwoofer Input sym tris e Les broches des prises XLR doivent tre affect es comme suit 1 terre 2 3 sensibilit en entr e de l IC 118 BA est de 4 dBu Attention Ne raccordez jamais directement les trajets de signaux Line ou Master de la table de mixage la prise Input du subwoofer car celle ci travaillerait sans contr leur c est dire sans diviseur de fr quence correction ni protection du syst me Reportez vous cet effet au chapitre 2 Installation et c blage e Through Branchement Sortie parall le pour transmission du signal du subwoofer un autre IC 118 BA au moyen d un c ble XLR Les broches des prises XLR doivent tre affect es comme suit 1 terre 2 3 T MOINS DE CONTR LE I
89. stem erlaubt eine freie Netzwerk Topologie so lassen sich die Lautsprecher seriell sternf rmig und in jeglicher Kombination von beiden anordnen Die Lautsprechersysteme werden mit hochwertigen RJ45 kompatiblen Ethercon Verbindern vernetzt weitere Komponenten werden ber CAT5 Kabel mit RJ45 Steckern angeschlossen So l sst sich auf einfache Art und Weise ein Netzwerk einrichten Im Netzwerk erkannte Lautsprecher besitzen werkseitig festgelegte Namen die zur benutzerdefinierten Zuordnung editierbar sind So lassen sich mit der Flash Funktion die entsprechenden Devices lokalisieren wenn die blinkende LED auf der Front des entsprechenden Lautsprechers aktiviert wird blinkt f r ca 6 Sekunden 4 3 INSTALLATION UND FIRMWARE UPDATE Lesen Sie diese Anleitung bitte sorgf ltig durch be vor Sie mit der Installation der Software beginnen VORBEREITUNG Notwendige Dateien Zur Installation der Software werden folgende Dateien ben tigt die sie in einem Ordner auf der Festplatte speichern sollten e Setup exe e Setup ini e SetupSecure msi e Code f r PodWare txt enth lt den Entsperrcode zur Installation der Software Update Windows XP mit dotnetfx exe dotframework Achtung Zum Betrieb der PodWare ist es unbedingt notwendig dass Sie mindestens dotnetframework 2 0 Service Pack 1 auf Ihrem Computer installiert haben Hinweis Unter Umst nden wird zu Beginn der Installation eine Verbindung zum Microsoft Serve
90. subwoofer IC 118 BA du haut Pour ce faire d vissez les crous griffes M10 de l enceinte puis montez la place les triers de l unit d inclinaison l aide des vis de fixation vis B filetage long Otez ensuite les deux crous Mio de l unit Mid High IC 112 LA Fixez les deux vis de r glage C sur l unit Mid High de mani re ce qu elles se positionnent dans la grande encoche D de l unit d inclinaison Vous pouvez pr sent r gler l angle de l unit Mid High 5 10 15 en la relevant et en la suspendant selon l angle d sir 118 BA Fig 8 Montage et utilisation de l unit d inclinaison ICON 3 RACCORDS ET COM MANDES 3 1 ICON 1C 112 LA COMMANDES IC 112 LA e User Settings On Off Ce commutateur permet de d finir le mode de travail du syst me Dans la configuration User Settings Off le contr leur utilise ses r glages d usine En mode User Settings On il recourt aux derniers r glages d finis avec le PodWare Remarque Placez les commutateurs dans la position souhait e avant la mise en service du syst me Lors du r glage du syst me Gain EQ Delay avec l interface BVNet et le PodWare install sur votre ordinateur portable veillez ce que tous les commutateurs unit Mid High soient sur User Settings On La lecture des donn es d exploitation est possible dans les deux positions du commutateur e Input Sensitivity La modifi
91. t Scan PodWare sucht das komplette Netz nach angeschlossenen Devices 12 15 und 24 dB Die Copy and Paste Funktion ist hier nur bei den einzelnen ab Werten m glich 4 Delay Einstellbar in Zeit 0 0116 ms bis 201 ms bzw in Entfernung Locating Es besteht die M glichkeit mit dem DSP Modul eine Wink LED b E as hha P Ud eil a dd metrisch 3 97 mm bis 69 m und in Fu engl feet 0 01 ft bis 226 ft anzusteuern Hat der Benutzer in der Pod Ware mehrere Devices angeschlossen und deren Panel aufgemacht wird durch kurzzeitiges Blinken dieser LED beim Bet tigen dieses Icons angezeigt welcher Lautsprecher DSP Device zu diesem Panel geh rt Diese Funktion dient also zur Identifikation der Device DSP Moduls in der Mid High Unit 5 Status Gibt den aktuellen Betriebstatus an Driver zeigt die korrekte Impedanz der Lautsprecher an gr n ok rot Ver nderung Hinweis Die dauerhafte Ver nderung der Impedanz kann auf einen defekten Lautsprecher schlieRen lassen Mute Schaltet alle am Netz angeschlossenen Devices gleichzeitig in den 5 5 e Amplifier Clip zeigt entsprechend die Ubersteuerung am Verst rker an Mute Zustand 6 Gain Anzeige Eingabefeld f r den Eingangspegel e LIM A und B Anzeige des Software Limiters im DSP Modul 4 Launch all Panels Mit dieser Funktion werden alle Device Panels aller am Netzwerk angeschlossenen Ger te gleichzeitig ge ffnet Jeder angeschlossene Lautsprecher m
92. tes les prises des c bles de raccordement doivent tre si possible viss es ou verrouill es sur le bo tier L utilisation de fusibles rafistol s ou court circuites est inadmissible seulement 1EC127 L utilisation de fusibles rafistol s ou court circuites est inadmissible Ne jamais interrompre la connexion du circuit protecteur Il est conseill de ne pas toucher aux surfaces pourvues du signe HOT fig 2 voir en bas aux parois arri res ou caches munis de fentes d a ration l ments d a ration et leurs caches ansi qu aux tubes et leurs caches Ces l ments pouvant atteindre des temp ratures l v es pendant l utilisation de l appareil e Les Niveaux de puissance l v s peuvent entrainer des l sions auditives durables Evitez donc la proximit de haut parleurs utilis s haute puissance Lors de haute puissance continue utilisez une protection auditive BRANCHEMENT SUR LE SECTEUR L appareil est con u pour une utilisation continue La tension de fonctionnement doit concorder avec la tension secteur locale Le raccordement au r seau l ctrique s effectue avec l adaptateur ou le cordon d alimentation livr avec l appareil Adaptateur Un c ble de raccordement abim ne peut tre remplac L adaptateur est inutilisable Evitez un raccordement au r seau par des bo tes de distribution surcharg es La prise de courant doit tre plac e proximit de l appareil et facile atteindre L
93. ts in a band pass housing The top compartment serves as the speaker cabinet for the 18 woofer the bottom compartment houses the power amp All control signals are routed to the subwoofer by way of the mid high unit s Sub Out port Heads up The IC 118 BA is a system subwoofer designed specifically for use with the IL 112 LA mid high unit It is not equipped with a crossover so it runs without the benefit of frequency separation and limiting when deployed in any configuration other than an ICON system For this reason always ensure the audio signal goes to the 1C112 LA mid high unit s onboard controller first that is before you patch it into the subwoofer 1 3 TRANSPORT A convenient dolly is available making it so much easier to tote the system Use original HK AUDIO ICON covers to gear up your system for the rigors of the road Amply padded and protected against moisture your ICON system is sure to serve you well for a very long time to come ICON SERIES LTS 1 0 2 SETUP AND CABLE CONNECTIONS 2 1 ICON LTS The standard system comprises two IC 112 LA cabs and four IC 118 BA bins Figure 3 ICON LTS Always connect an ICON system by starting at the top and working your way down see figure 4 ICON LTS controller for the entire stack sits in the IC 112 LA mid high unit This cabinet s Sub Out port serves to route the filtered low frequency audio signal to the subwoofer as well as control signals sent remotely
94. ture limit was exceeded The included CD containing installation software provides more info on handling the application 5 TIPS AND TRICKS 1 Do not expose electronic circuitry to moisturel Protect the system against rain when setting it up outdoors Keep soft drinks beer and any other liquids well away to prevent electronic components from short circuiting 2 Ensure rear panel vents are free of dirt and debris and proper ventilation is assured Otherwise electronic components may overheat and suffer damage 3 ICON systems deliver optimum sound so you should provide it with optimum input signals Noise such as humming is generally caused by defective cables the wrong type of cords or unbalanced signals routed into the mixing console Check all signal and mains cables 4 Prevent distortion Not only is it unpleasant to your audience s ears it also endangers your equipment Make sure all components connected directly and indirectly to the ICON system have sufficient power ratings and that they don t distort because they re running at their respective limits Feed an undistorted signal to the system that doesn t have to be cleaned up by backing off the Gain knob 5 Avoid ground loops You may encounter a ground loop when the mixer is grounded via a mains cord which isn t connected to the same mains circuit as the ICON system To avoid this problem always connect the ICON system and the mixing console to the same electrical
95. u In Out O Fig 5 Sch ma des connexions du syst me ICON LTS double Les broches des prises XLR doivent tre affect es comme suit 1 terre 2 3 Fig 5 voir ci dessous Installation Dans le cas du syst me ICON double il convient tout particuli rement de veiller installer les deux stacks de chaque c t et ce afin d viter les ph nom nes d extinction ou de sur l vation effets de phase sur la r ponse en fr quence Les subwoo fers peuvent aussi tre install s c te c te Fig 6 Angle de montage de deux stacks ICON IC 112 LA e Throu Sub Out System Guard BVNet O IC 118 BA System Guard e In Throu Out IC 118 BA System Guard o 0 In Throu In Out O 2 3 ICON IC 112 LA SUSPENDU Pour suspendre l unit Mid High veuillez utiliser des nacelles ou des c bles de fixation de nacelle Aeroquip disponibles en option HX kon ok lC 172 Fig 7 ICON IC 112 LA avec rails Aeroquip Remarque Utilisez exclusivement des arr ts agr s ex Half Coupler brides de fixation c bles de s curit etc afin de garantir la s curit Les points de suspension utilis s doivent tre concus pour la charge en question poids ICON LT 112 LA 49 9 kg 110 165 2 4 UTILISATION DE L UNIT D INCLINAISON ICON Commencez par monter les triers de l unit d inclinaison ICON A sur le
96. ufnahme Interne Sicherungen Spannungsbereich Netzanschluss 1050 Watt IC 112 LA 1880 Watt IC 118 BA 4 5 IC 112 LA 8 1 A IC 118 BA 4 AT 10 AT IC 112 LA 10 AT IC 118 BA 220 V 240 V Neutrik Powercon F r die nachfolgend bezeichneten Erzeugnisse ICON IC 112 LA ICON IC 118 BA wird hiermit best tigt dass sie den wesent lichen Schutzanforderungen entsprichen die in der Richtlinie des Rates zur Angleichung der Rechtsvorschriften der Mitgliedsstaaten ber die elektromagnetische Vertr glichkeit 2004 108 EG und der Niederspannungsrichtli nie 2006 95 EG festgelegt sind Diese Erkl rung gilt f r alle Exemplare und best tigt die Ergebnisse der Messungen die durch die Qualit tssicherung der Fa STAMER Musikanlagen GmbH durchgef hrt wurden Zur Beurteilung des Erzeugnisses hinsichtlich elektromagnetischer Vertr glichkeit wurden folgende Normen herangezogen EN61000 6 1 EN61000 6 2 Zur Beurteilung der Einhaltung der Niederspan nungsrichtlinie wurde folgende Norm herange zogen EN 60065 Diese Erkl rung wird verantwortlich f r den Hersteller SIM STAMER MUSIKANLAGEN GMBH Magdeburger Str 8 66606 St Wendel abgegeben durch Tau Lothar Stamer Dipl Ing Gesch ftsf hrer St Wendel den 29 06 2009 Version 2 0 08 2008 23 ICON IC 112 LA ICON IC 118 BA 24 21 12 9 3 0 21 18 W 9 5 Mo 3 18 15 15 12 I a D O 24 21 21
97. y and the system is on e Double click setup exe and follow the instructions on the screen The software installs automatically Restart the computer even if you are not prompted to do so Selecting the COM Port Go to the Windows XP Start menu and select PodWare from the list A menu opens Select gt Network gt Com Port and then the com port 1 to 4 that you have connected to the BVNet interface using a serial cable Tip Go to the Windows Device Manager to learn the com port number gt Start gt Control Panel gt System gt Hardware gt Device Manager gt Com and LPT Check here to verify if an USB to serial adaptor has been installed properly Go to the Windows XP Start menu and select PodWare from the list This launches the application To get help using PodWare go to gt Help gt Help Topics There you ll find an HTML catalog with guidelines ICON SERIES LTS 1 0 Installing BVNet Modul Interface To learn more about installing the BV Net Interface please read the User Guide that comes with it 4 4 How TO HANDLE THE SOFTWARE double click launches PodWare once it has been installed e Connect the ICON system to the BVNet interface and then connect the laptop HK Audio BV Network File Preferences Network Device Panel Help Figure 12 The PodWare s basic functions 1 Net Scan PodWare scans the entire network searching for connected devices 2 Locating This is a convenient way
Download Pdf Manuals
Related Search
Related Contents
American Standard Double Robe Hook 2555.021 User's Manual 取扱説明書 取扱説明書 Good Measurement Practices for DNA Analysis with the Agilent Error Guide Template - Campbell Company Pedestrian Safety Dynex DX-40L150A11 User's Manual DOCX Signer User Manual - Digital Signature Software Belkin F7P118VFC00 Hasbro 08855 Games User Manual User Manual Copyright © All rights reserved.