Home
Bedienungsanleitung Operating Instructions
Contents
1. Connect the output 5 of the first device with the input 4 of the second device the output of the second device with the input of the third device etc Then address your laser according to the DIP switch assignment table Please note that the laser has 4 channels Set the DMX start address as follows 10 th Function switch To assign channel 6 to your laser bring the DIP switch 2 value 2 and DIP switch 3 value 4 into the position on 2 4 6 The laser is assigned to the channels 6 to 9 Binary g No Q 8383 001 D jo 128 192 amp o 3 gm BIBEBEBESR a7 ePej 12 177 N 5 BS3858858 PP PeeE 2 017 BSEBEBSSESER PPPP2 13 193 ESSENZE e el 3 033 E ES3BE5885R om 256 gsz82338 17 ieena BIBEBESBESEN 5 065 3 HEF E E A Da a EEEa 88385835358 16 241 Bee e e ej 3838593388 Bee y BS388388 8 3 ae 85358533888 EEEE 11 161 pupun 6 32 1064 128 258 BISBENERg EIKE 22 337 DMXx Protokoll Kanal chi Ch 2 _DMXvalue Beschreibung 0 255 20 gobos 0 255 13 0 19 keine Funktion keine Rotation 0 255 ___ graduelle Geschw 0 255 23 0 11 Ch 3 Ch 4 Zur Verst rkung der Laser Effekte empfiehlt Scanic den Gebrauch einer Nebelmaschine Achten Sie jedoch darauf dass Sie den Raum nicht ber m ig vernebeln da sonst der
2. Das Produkt darf nur bei einer Temperatur zwischen 5 und 45 Grad Celsius betrieben werden Optimale Arbeitsbedingungen f r diesen Laser liegen zwischen 18 und 30 Grad Celsius Sch tzen Sie das Produkt dazu vor direk ter Sonneneinstrahlung oder anderweitiger externer Erhitzung wie z B durch Heizk rper Wenn das Produkt von einem kalten Raum in einen warmen Raum gebracht wurde darf es erst in Betrieb genommen werden wenn es Zimmertemperatur erreicht hat da das dabei entstehende Kondenswasser es unter Umst nden zerst ren kann Das Produkt muss vor Staub gesch tzt werden Staub kann die Schutzisolierung reduzieren was zu t dlichen Stromschl gen f hren kann Das Produkt darf nur zwischen H henlagen von 20 m unter bis 2000 m ber Normalnull NN in Betrieb genommen werden Das Produkt darf nicht bei Gewitter betrieben werden da ansonsten eine Zerst rung durch Uberspannung droht Das Produkt darf nur in einem Mindestabstand von 1 m zu den beleuchte ten Objekten betrieben werden The product must be operated and stored in a dry environment only Splash water rain humidity fog may reduce the protective insulation which may lead to fatal electric shocks The limit value for relative humi dity is 50 at 45 C A minimum distance of 1 m to a fog machine must be observed fog saturation in the room must not reduce the visibility to below 10 m The product must be operated at a temperature range of between 5 C and 45 C o
3. study and observe all instructions carefully ensure that everybody and anybody involved in the installation opera tion transport and storage of this product is suitably qualified verify whether any visible damage was caused during transport If the power cord housing or the light are damaged do not operate the devi ce contact your specialised dealer immediately 2 Supply Voltage Mains Cord and Connection to Mains ATTENTION AN DANGER OF LIFE RISK OF FIRE RISK OF SHORT CIRCUIT Der Umgang mit Netzspannung Netzkabeln und Netzanschl ssen erfor dert wegen der Gefahr eines lebensgef hrlichen elektrischen Schlages der Gefahr eines Brandes und der Gefahr eines Kurzschlusses besondere Vorsicht Bitte beachten Sie insbesondere folgende Hinweise Produkte die an Netzspannung betrieben werden geh ren nicht in Kinderh nde Stellen Sie deshalb sicher dass bei Anwesenheit von Kindern in der N he des Produktes eine dauerhafte Aufsicht erfolgt In gewerblichen Einrichtungen sind die Unfallverh tungsvorschriften des Verbandes der gewerblichen Berufsgenossenschaft zu beachten In Schulen Ausbildungseinrichtungen Hobby oder Selbsthilfewerkst tten ist das Betreiben des Ger tes durch geschultes Personal verantwortlich zu berwachen berpr fen Sie das Produkt regelm ig auf Besch digungen des Netzkabels Sollten Sie dabei Sch den am Netzkabel entdecken nehmen Sie das Produkt nicht in Betrieb bzw au er Betrieb S
4. Sch den die aus Nichtbeachtung etwaiger Vorschriften und Richtlinien resultieren 1 Vor der Inbetriebnahme ACHTUNG LEBENSGEFAHR BRANDGEFAHR KURZSCHLUSSGEFAHR AAA Notes on Safety The notes on safety in these operating instructions especially the notes regarding the operation of the laser are applicable within the scope in the Federal Republic of Germany When used in other countries please contact your local authorities for the applicable safety regulations Scanic is not liable for damage resulting from the non compliance with applicable rules and regulations 1 Before Operation ATTENTION AN DANGER OF LIFE RISK OF FIRE RISK OF SHORT CIRCUIT Vor der ersten Inbetriebnahme dieses Produktes bitten wir Sie diese Bedienungsanleitung aufmerksam zu lesen alle Anweisungen sorgf ltig zu studieren und zu befolgen sicherzustellen dass jeder der mit Installation Betrieb Transport und Lagerung dieses Produktes betraut ist daf r geeignet ist zu berpr fen ob kein offensichtlicher Transportschaden vorliegt Sollten Sie Sch den an Stromkabel Geh use oder Leuchtmittel entdecken neh men Sie das Ger t nicht in Betrieb setzen Sie sich unbedingt mit Ihrem Fachh ndler in Verbindung 2 Netzspannung Netzkabel und Netzanschluss ACHTUNG LEBENSGEFAHR BRANDGEFAHR KURZSCHLUSSGEFAHR AAA Prior to the initial operation of this product we ask you to read these operating instructions with great care
5. Schutzma nahmen betreten werden Die Grenzwerte f r die Bestrahlung d rfen im Zuschauerbereich keinesfalls berschritten werden Der Showlaserbereich muss vor Inbetriebnahme ausgemessen und errech net werden Halten Sie den Laserbereich m glichst klein This product can only be operated as a suspended installation Should your Scanic lighting effect show any signs of damage do not suspend the device In this case have your lighting effect repaired by your specialised Scanic dealer Scanic does not accept responsibility or liability for damage to property or personal injury resulting from an improperly suspended installation The suspended installation of this lighting effect must be carried out by trained and professional staff only The suspended installation of this lighting effect necessitates a suitable suspension system The suspended installation of this lighting effect must only be carried out with the appropriate materials The lighting effect must never be fixed swinging freely in the room Please ensure that the fixing screws on the installation arm are adequate ly tightened Observe the regulations if the product is used for commercial operation Consider the EN 60589 2 17 when mounting the device No individuals should linger underneath the lighting effect during suspen ded installation It is a must to install this device with a second independent fixture Such a second fixture must guarantee in the e
6. nahmen und Vorschriften f r den Einsatz dieses Lasers Congratulations on purchasing this Scanic RayGun 30G Thank you for extending your trust in our technology This product complies with the requirements stipulated by applicable European and national regulations conformity has been proven and the respective declarations and documents have been deposited with the manufacturer This product complies with the German protection class and features a protective insulation For reasons of safety and approval CE the personal reconstruction and or modification of this product is prohibited Please observe that damage cau sed by modifications performed manually to this device is not covered by the warranty This product leaves our works in perfect condition Please observe all notes in these operating instructions to warrant this condition and the safe ope ration of the product Any damage caused as a result of the non compliance with these opera ting instructions leads to the expiration of any warranty claim The manu facturer does not accept liability for any damage to property or for perso nal injury resulting from the improper handling of the product or non observance of the operating instructions Store these operating instructions in a safe place for later reference and pass them to any new holder when selling or lending or leaving this devi ce in the hands of any other party Application According to Purpose This prod
7. Laser muss ber eine manuelle Sicherheitsabschaltung verf gen Diese muss gew hrleisten den Laserstrahl jederzeit unterbrechen zu k n nen Sollte der Laser an einem schwer erreichbaren Ort Traverse instal liert sein muss dieser ber mindestens eine schaltbare Steckdose ange schlossen werden The handling of supply voltage mains cords and connections to mains calls for particular care considering the risk from a life threatening electric shock the risk of fire and the risk of short circuits Please observe the fol lowing notes in particular Products operating on supply voltage should be kept out of the reach of children Therefore ensure the permanent supervision if children are in the immediate vicinity of the product For commercial facilities the regulations on the prevention of accidents of the respective trade association must be observed The operation of this equipment at schools training facilities and hobby or self help workshops must be supervised responsibly by trained personnel Check the product regularly for any damage to the mains cord Should you discover any damage to the mains cord do not operate or disconnect this product Secure the product against accidental operation and contact your specialised dealer Always separate the product from mains by holding the mains plug by the handling surface Never disconnect by holding the line cord Be sure to connect the product exclusively to 230 V 50 Hz A C Alw
8. Laserstrahl im Nebel untergeht Nach Ende der Benutzung trennen Sie das Produkt vom Netz 9 Reinigung Das Produkt muss regelm ig von Staub anderen Ablagerungen und Verschmutzungen gereinigt werden weil ansonsten die Schutzisolierung reduziert werden k nnte was zu t dlichen Stromschl gen f hren kann Trennen Sie das Produkt vor jeder Reinigung unbedingt vom Netz Dieses Produkt sollte nur mit einem leicht feuchten Tuch gereinigt werden verwenden Sie niemals aggressive Reinigungsmittel L sungsmittel oder Waschbenzin zum Reinigen Befreien Sie die Schutzscheibe regelm ig von Staub und eventuellen Nebelfl ssigkeitsr ckst nden Stellen Sie sicher dass das Produkt komplett trocken ist bevor Sie es nach der Reinigung wieder in Betrieb nehmen DMX Protocol Channel DMX value Description Cch 0 255 20 gobos 0 255 13 0 19 Ch2 0 63 Noeffet S 64 127 Pan rotation S 128 191 Tilt rotation 0 192 255 Pan amp tilt rotation Ch3 0 127 No rotation 0 O 128 255 Center rotation Ch4 0 255 11 gradual speed 0 255 23 0 11 To reinforce the laser effects Scanic recommends the use of a fog machi ne Please observe that the room must not be oversaturated as otherwise the laser beam will be drowned in the fog After the end of operation disconnect the device from mains 9 Cleaning The product must be freed regularly from dust other deposits and conta mination as this
9. Sorge zu tragen dass ein Sachverst ndiger maschinentechni sche und sicherheitstechnische Einrichtungen mindestens alle vier Jahre im Umfang einer Abnahmepr fung kontrolliert Die Installationsbefestigung muss so beschaffen sein dass sie ber die Dauer von 60 Minuten ohne nachteilige Formver nderung dem 10 fachen der Nutzlast standhalten kann W hrend jeglicher Montagearbeiten ist das unn tige Aufhalten unterhalb der Installationen strengstens untersagt Das Lichteffektger t muss bei der berkopfmontage zwingend durch ein Sicherheitsfangseil gesichert werden Das Seil muss dabei dem 12 fachen des Lichteffektgewichts standhalten Benutzen Sie Fangseile mit Schnellverschlussgliedern Der Fallabstand darf maximal 20cm betragen Defekte Fangseile oder Fangseile die schon einer Belastung durch einen Fall ausgesetzt waren d rfen nicht verwendet werden Bei der Auswahl des Installationsortes muss zuvor der Zuschauerbereich und der Showlaserbereich definiert werden Der Laser muss so installiert werden dass die Projektionen in mind 3 5 m H he stattfinden Die Laser Projektionen d rfen nur im Showlaserbereich dargestellt werden Der Showlaserbereich ist ein Gefahrenbereich der durch den Betrieb des Showlasers entsteht In diesem Bereich k nnen vorgegebene Grenzwerte berschritten werden Dieser Bereich muss f r unbefugte Personen uner reichbar sein Der Showlaserbereich darf nur wenn zwingend erfoderlich unter Einhaltung der
10. ays ensure during installation operation transport and when storing the product that the mains cord is not exposed to possible mechanical damage or damage caused by humidity fluids heat or cold The product s cable entry must not be exposed to stress from pull Only create the mains connection once the product has been installed Always connect the mains plug last The product must only be connected to a proper outlet of the public sup ply grid Connect the mains cord to suitable outlets only Use extension cords in compliance with specifications only Do not allow the mains cord to come into contact with other cords Ensure during installation operation transport and storage that none of the cables are freely exposed Never touch the mains cord mains plug and outlets with wet or damp hands When not using the product and prior to cleaning always disconnect the product from mains To do so hold the mains plug by the handling surface and never pull the mains cord The laser must have a manual safety cut off This cut off must ensure that the laser beam can be interrupted at any moment Should the laser be installed at a location which is difficult to reach tie bar it must be con nected to at least a switch operated outlet 3 Geh use ACHTUNG AN LEBENSGEFAHR VERBRENNUNGSGEFAHR BRANDGEFAHR KURZSCHLUSSGEFAHR 3 Housing ATTENTION DANGER OF LIFE RISK OF BURNS RISK OF FIRE RISK OF SHORT CIRCUIT Schra
11. chtungen sowie die Unfallverh tungsvorschrift Laserstrahlung Beachten Sie au erdem die DIN Richtlinien zur Sicherheit von Laser Einrichtungen und Showlaser und Showlaseranlagen Anforderungen und Pr fung sowie Abschirmungen an Laserarbeitspl tzen sicherheitstechnische Anforderungen und Pr fung Der Laser darf niemals ohne Aufsicht betrieben werden Die Bedieneinrichtung des Lasers darf sich nicht im Showlaserbereich befinden Der Laser darf nur in einem abgesperrten Showlaserbereich betrieben wer den Richten Sie den Laserstrahl niemals auf Personen oder Tiere aus Sichern Sie den Laser unbedingt gegen Positions nderungen unbeabsichtigte Never remove the housing The inside of this device houses laser diodes Always ensure during installation operation transport and when storing the product that no shocks or other forces impact the housing The housing must be installed exclusively via the mounting bracket The housing must be fixed with an appropriate safety rope The housing must not touch onto any other devices or objects during ope ration Easily flammable materials e g decoration material and other surfaces and objects must maintain a minimum distance of 1 m to the housing A sufficient circulation of air must occur at all times Do not touch the housing during operation it will heat up The housing is safe to touch approx 5 minutes following the end of operation Flu
12. e stellt werden Der Laser spielt nun ein automatisches Programm ab DMxX Modus Um im DMX Modus arbeiten zu k nnen m ssen zun chst alle Scanic Ger te mit einem handels blichen 3poligen DMX Kabel XLR verbunden werden Verbinden Sie nun den Ausgang 5 des ersten Ger tes mit dem Eingang 4 des zweiten Ger tes den Ausgang des zweiten Ger tes mit dem Eingang des 3 Ger tes usw Adressieren Sie nun Ihren Laser gem der DIP Switches Belegungstabelle Ber cksichtigen Sie dass der Laser 4 Kan le hat Sie stellen die DMX Startadresse wie folgt ein Nummer Bin r Nummer th 8l 641 Function switch M chten Sie Ihrem Laser z B den Kanal 6 zuweisen so positionieren Sie die DIP Switches 2 Wert 2 und den DIP Switches 3 Wert 4 in Stellung On 2 4 6 Der Laser belegt somit die Kan le 6 bis 9 DMX mode 1 9 expression adresses Stand Alone Modus Music Control To operate the music control mode set the DIP switches 6 to those posi tions as listed in the Dip switch assignment table Use the sensitivity control 1 to set the laser s sensitivity via the micro phone to the music s low frequencies Auto Mode To operate in Auto mode set the DIP switches 6 to those positions as listed in the DIP switch assignment table The laser will then run a programme automatically DMX Mode To operate in DMX mode all Scanic devices must be connected using a conventional 3 pole DMX cord XLR
13. en Ersetzen Sie die Sicherung indem Sie den Sicherungshalter mit einem pas senden Schraubenzieher aus dem Geh use drehen Entfernen Sie die defekte Sicherung und setzen Sie die neue Sicherung in die Sicherungshalterung ein Schrauben Sie die Halterung wieder fest Das Ger t darf niemals bei ge ffnetem Geh use mit dem Netz verbunden sein 6 Betriebsumgebung ACHTUNG AN LEBENSGEFAHR VERBRENNUNGSGEFAHR BRANDGEFAHR KURZSCHLUSSGEFAHR Disconnect the product from mains at all costs before changing a fuse Only replace the fuse by a fuse of same type and rating An incorrect fuse could damage or destroy the lighting effect Replace a fuse by unscrewing the fuseholder cover with an approprioate screw driver Remove the old fuse and place the new fuse inside the hol der Replace the fuseholder and tighten it Never connect the lighting effect to the mains while the housing is still open 6 Operating Environment ATTENTION DANGER OF LIFE RISK OF BURNS RISK OF FIRE RISK OF SHORT CIRCUIT Das Produkt darf nur im Trockenen betrieben und gelagert werden Spritzwasser Regen Feuchtigkeit Nebel k nnen die Schutzisolierung redu zieren was zu t dlichen Stromschl gen f hren kann Der Grenzwert f r die relative Luftfeuchtigkeit liegt bei 50 bei 45 Grad Celsius Zu einer Nebelmaschine muss ein Mindestabstand von 1 m eingehalten werden die Nebels ttigung im Raum darf eine Sichtweite von 10 m nicht unterschrei ten
14. gen dass beim Umgang mit Lasern die Angestellten mindestens einmal j hrlich ber die Gefahren von Laserstrahlung und mit den vorhandenen Sicherheitseinrichtungen und den erforderlichen Schutzma nahmen vertraut gemacht werden F r etwaige Sch den die aus einer mit den Vorschriften abweichenden Benutzung resultieren bernimmt der Hersteller keine Haftung 5 Sicherung ACHTUNG LEBENSGEFAHR AAA The laser must be set up as such that the laser beam never migrates The laser has not been designed for continuous operation Never use the laser for more than 4 hours The laser must be operated and supervised by trained professionals only The laser must never be operated by private individuals The instructed individual must monitor the path of the beam and if necessary deactivate the device The employer must ensure that employees are familiarised with how to handle lasers and with the risks of laser radiation and the safety installa tions in place as well as the necessary safety measures at least once a year The manufacturer does not accept liability for possible damage resulting from any operation other than such as laid down in the regulations 5 Fuse AAA ATTENTION DANGER OF LIFE Trennen Sie vor dem Austausch der Sicherung das Ger t unbedingt vom Netz Stellen Sie bei einem Austausch sicher dass Sie nur geeignete Sicherungen verwenden Eine falsche Sicherung kann das Ger t besch di gen oder zerst r
15. ichern Sie das Produkt gegen unbeabsichtigten Betrieb und setzen Sie sich mit Ihrem Fachh ndler in Verbindung Trennen Sie das Produkt immer vom Netz indem Sie den Netzstecker an der Grifffl che anfassen Ziehen Sie niemals an der Netzleitung Stellen Sie sicher dass Sie das Produkt ausschlie lich an 230 V 50 Hz Wechselspannung anschlie en Stellen Sie bei Installation Betrieb Transport und Lagerung des Produktes stets sicher dass das Netzkabel weder mechanisch noch durch Feuchtigkeit Fl ssigkeit Hitze oder K lte besch digt werden kann Die Kabeleinf hrung am Produkt darf nicht durch Zuge belastet werden Stellen Sie sicher dass der Netzanschluss erst nach dem Aufbau des Produktes erfolgt Den Netzstecker immer als letztes einstecken Das Produkt darf nur an eine ordnungsgem e Netzsteckdose des ffent lichen Versorgungsnetzes angeschlossen werden Stecken Sie das Netzkabel nur in geeignete Steckdosen ein Benutzen Sie nur vorschriftsm ige Verl ngerungskabel Lassen Sie das Netzkabel nicht mit anderen Kabeln in Kontakt kommen Stellen Sie bei Installation Betrieb Transport und Lagerung stets sicher dass keine Kabel frei herumliegen Fassen Sie Netzkabel Netzstecker und Netzsteckdosen nie mit nassen oder feuchten H nden an Trennen Sie das Produkt bei Nichtbenutzung und vor jeder Reinigung vom Netz Fassen Sie dazu den Netzstecker an der Grifffl che an und ziehen Sie niemals an der Netzleitung Der
16. ids must not enter the housing as this could reduce the protective insu lation and may trigger short circuits which may lead to fatal electric shok ks If fluids have entered disconnect the mains plug immediately and secure the product against unintentional operation and contact your spe cialised dealer Damage caused as a result of fluids entering the housing is exempt from warranty No metal parts or other items must enter the housing as this may reduce the protective insulation or trigger short circuits which may lead to fatal electric shocks If metal parts or other items have entered disconnect the mains plug immediately secure the product against unintentional opera tion and contact your specialised dealer Damage caused by metal parts or other items in the housing is exempt from warranty 4 Laser A A When operating lasers observing the notes on safety and legal regulations is mandatory ATTENTION DANGER Please observe Regulations and notes on safety are only partially repro duced here The operator shall independently obtain information regarding the current national rules and regulations which must be observed Scanic is not liable for damage resulting from the non compliance with rules and regulations Public events require the appointment of a laser safety officer For installa tions in public buildings e g night clubs venues or pubs the lasers must be approved by the local TUV Technical Control Board and o
17. ie Schutzisolierung reduzieren oder Kurzschl sse aus l sen k nnte was zu t dlichen Stromschl gen f hren kann Im Fall von ein gedrungenen Metallteilen oder sonstigen Gegenst nden m ssen Sie sofort den Netzstecker ziehen das Produkt gegen unbeabsichtigten Betrieb sichern und sich mit Ihrem Fachh ndler in Verbindung setzen Sch den die durch Metallteile oder sonstige Gegenst nde im Geh use entstehen sind von der Gew hrleistung ausgeschlossen Beim Einsatz von Lasern sind zwingend die Sicherheitsvorschriften und die rechtlichen Vorschriften einzuhalten 4 Laser ACHTUNG GEFAHR A Beachten Sie Vorschriften und Sicherheitshinweise werden hier nur partiell wiedergegeben Der Betreiber hat sich selbst ndig um die aktuellen natio nalen Vorschriften und Richtlinien zu bem hen und diese zwingend einzu halten Scanic haftet nicht f r Sch den die aus Nichtbeachtung etwaiger Vorschriften und Richtlinien resultieren Bei ffentlichen Veranstaltungen ist ein Laserschutzbeauftragter zu bestel len Bei der Installation in ffentlichen Geb uden wie z B Diskotheken Veranstaltungshallen oder Gastst tten sind die Laser vom rtlich zust ndi gen TUV und oder der Berufsgenossenschaft abzunehmen Beachten Sie die Berufsgenossenschaftlichen Informationen f r Sicherheit und Gesundheit bei der Arbeit speziell die BG Informationen zu Laser Einrichtungen f r Show oder Projektionszwecke Betrieb von Lasereinri
18. ing screws on the installation arm and bring the laser into the desired position Run all projection images of the laser to ensure that all patterns are pro jected within the show laser perimeter only Also check for reflecting or shiny surfaces in the laser s projection area e g mirror balls As the case may be remove reflecting or deflecting objects Then tighten the fixing screws The laser beam must never be freely adjusted without the use of tools 8 Operation AAA ATTENTION RISK OF HEALTH Bedienelemente zO LIDKIDUODUEN OF Empfindlichkeitsregler Mikrofon LED DMX Eingang DMX Ausgang Dip Switches DR WN Controls Sound sensitivity knob Microphone LED DMX input DMX output Dip switches OY OAU 7 Stromkabel Anschluss ACHTUNG AN LEBENSGEFAHR VERBRENNUNGSGEFAHR BRANDGEFAHR KURZSCHLUSSGEFAHR 7 Mains connection ATTENTION DANGER OF LIFE RISK OF BURNS RISK OF FIRE RISK OF SHORT CIRCUIT Schlie en Sie den Netzstecker zun chst an die Netzsteckdose an Wenn Sie das Produkt zum ersten Mal in Betrieb nehmen kann es zu Rauch und Geruchsentwicklung kommen dies stellt keinen Fehler dar Vermeiden Sie es das Produkt schnell nacheinander mit dem Netz zu ver binden und es wieder vom Netz zu trennen Warten Sie immer einige Minuten bis zur n chsten Inbetrieb bzw Au erbetriebnahme Blicken Sie niemals w hrend des Betriebes in die Lichtquelle Dies kann bei e
19. lassung des Produktes weiter Bestimmungsgem e Verwendung Bei diesem Produkt handelt es sich um einen Showlaser mit sichtbarer Strahlung im Wellenl ngenbereich von 532 nm Dieser Laser ist aus schlie lich zur Erzeugung von Lichteffekten f r den Unterhaltungsbedarf im professionellen Bereich konzipiert Das Produkt wird dabei an das Stromnetz angeschlossen Dieses Produkt ist f r den Anschluss an 230 V 50 Hz Wechselspannung zugelassen und wurde ausschlie lich zur Verwendung in Innenr umen kon zipiert Wird das Ger t anders verwendet als in dieser Bedienungsanleitung beschrieben kann dies zu Sch den am Produkt f hren und der Gew hrleistungsanspruch erlischt Au erdem ist jede andere Verwendung mit Gefahren wie z B Kurzschluss Brand elektrischem Schlag etc ver bunden Au erdem kann es zu gef hrlicher Strahlungsexposition kommen Die vom Hersteller festgelegte Seriennummer darf niemals entfernt wer den da ansonsten der Gew hrleistungsanspruch erlischt Dieser Laser f llt nach DIN EN 60 825 1 der Laserklassifizierung unter die Klasse 3B Die Klasse 3B besagt Die Laserstrahlung ist gef hrlich f r das Auge und in besonderen F llen auch f r die Haut Laser der Klasse 3B sind genehmigungspflichtig ACHTUNG Gefahr durch Laserstrahlung Augen und Haut d rfen niemals direkt der Laser Bestrahlung ausgesetzt werden Laserstrahlung kann zu Augen und Hautsch den f hren Beachten Sie unbedingt alle Schutzma
20. may reduce the protective insulation which may lead to a fatal electric shock Before cleaning always disconnect the product from mains This product should be cleaned with a moist cloth only never use aggres sive cleaning agents solvents or benzine for cleaning Free the shield regularly from dust and possible fog fluid residues Ensure that the product is completely dry before operating it again after cleaning 10 Transport 10 Transport AN VORSICHT AN CAUTION ZERBRECHLICH FRAGILE Um Transportsch den auszuschlie en verpacken Sie das Produkt bitte nur To avoid damage caused during transport wrap the product in its original in der urspr nglichen Originalverpackung und lassen beim Transport packaging only and handle it with great care during transport Vorsicht walten Technische Daten Technical Information Folgende Daten des Herstellers werden von der Global Distribution GmbH Global Distribution GmbH did not check the following manufacturer s data nicht auf Plausibilit t und Richtigkeit gepr ft for plausibility and accuracy Spannung 230 V AV 50 Hz Voltage 230 V AV 50 Hz Gesamtanschlusswert 30 W Total connected load 30w Laser 532 nm 30mW Laserdioden gr n Laser 532 nm 30mW laser diodes green Ma e 316 x 280 x 85 mm Dimensions 316 x 280 x 85 mm Gewicht 3 0 kg Weight 3 0 kg 10 And now enjoy the Scanic experience Scanic w nscht Ihnen nun viel Spa 11 COPYRIGHT Nachdruck verb
21. mpfindlichen Menschen epileptische Anf lle ausl sen Der Scanic RayGun 30 G Laser verf gt ber verschiedene Betriebsarten Diese stellen Sie anhand der DIP Schalter auf der R ckseite ein Die DIP Schalter Belegung f r die Auswahl der Betriebsmodi ist wie folgt Funktion N automatischer Betrieb First connect the mains plug to an outlet Operating the product for the first time may generate smoke and odour this is not a defect Avoid dis connecting the product repeatedly and quik kly from with mains Always wait a few minutes prior to the next dis con nection Never look into the light source during operation People prone to sensiti vity may suffer an epileptic fit The Scanic Raygun 30 G laser offers a variety of operation modes which can be set using the DIP switch to the back of the device The DIP switch assignment for the selection of the operating modes is as follows Function oo O Sound active mode DMX Modus 1 9 Adressen Stand Alone Modus Musiksteuerung Um im Musiksteuerungsmodus zu arbeiten m ssen die DIP Switches 6 in die Positionen wie in der Dipschalter Belegungstabelle aufgef hrt einge stellt werden Mit dem Empfindlichkeitregler 1 k nnen Sie einstellen wie stark der Laser durch das Mikrofon auf tiefe Frequenzen der Musik reagiert Auto Modus Um im Auto Modus zu arbeiten m ssen die DIP Switches 6 in die Positionen wie in der Dip Switches Belegungstabelle aufgef hrt eing
22. nd geschultes professionelles Personal durchgef hrt werden Eine aufgehangene Installation dieses Lichteffektger tes darf nur mit einem daf r geeigneten Tr gersystem erfolgen Eine aufgehangene Installation dieses Lichteffektger tes darf nur mit daf r vorgesehenen Materialien vorgenommen werden Es ist unzul ssig das Lichteffektger t frei schwingend im Raum zu befesti gen Achten Sie darauf dass die Feststellschrauben am Installationsarm gut festgezogen sind Beachten Sie bei gewerblichen Einsatz die Einhaltung von Sondervorschriften Bei der Montage sind die Bestimmungen der BGV C1 und EN 60598 2 17 zu befolgen Sorgen Sie daf r dass sich nach M glichkeit unterhalb der aufgehangenen Installation keine Personen befinden Das Ger t ist zwingend mit einer zweiten eigenst ndigen Befestigung anzubringen Die zweite Befestigung muss gew hrleisten dass im Ausfall der Haupthalterung keine Montageteile herabst rzen k nnen Der Lichteffekt muss ber einen daf r zugelassenen Haken an einem Traversensystem montiert werden Es ist daf r Sorge zu tragen dass ein Sachverst ndiger maschinentechni sche und sicherheitstechnische Einrichtungen vor der ersten Inbetriebnahme und nach wesentlichen nderungen vor der Wiederinbetriebnahme kontrolliert Es ist daf r Sorge zu tragen dass ein Sachverst ndiger maschinentechni sche und sicherheitstechnische Einrichtungen mindestens einmal im Jahr kontrolliert Es ist daf r
23. nly The optimum operating temperature for this laser ranges between 18 and 30 degrees Celsius Protect the product against direct exposure to sunlight or other heat such as from radiators If the product is taken from a cold environment into a warm environment it must only be taken into operation once it has reached ambient tempe rature since the condensation created by the difference in temperature may destroy the device Protect the product against dust Dust may reduce the protective insula tion which may cause fatal electric shocks The product must be operated at altitudes ranging between 20 m below and 2000 m above sea level only The product must not be operated during thunder storms risk of destruc tion from surge voltages The product must be operated at a minimum distance of 1 m to lit objects only 7 Installation ACHTUNG LEBENSGEFAHR AAA 7 Installation AAA ATTENTION DANGER OF LIFE Sie k nnen das Produkt nur aufgehangen betreiben Wenn dieses Lichteffektger t irgendwelche Anzeichen von Besch digung aufweist darf eine aufgehangene Installation nicht vorgenommen werden Lassen Sie in diesem Fall das Lichteffektger t durch Ihren Scanic Fachh ndler reparieren Scanic bernimmt keine Verantwortung oder Haftung f r durch unsachge m aufgehangene Installationen entstandene Sach oder Personensch den Eine aufgehangene Installation dieses Lichteffektger tes kann nur durch ausreiche
24. oten Reproduction prohibited SCANIC LIGHTING EFFECTS Global Distribution GmbH Schuckertstra e 28 48153 Muenster Germany Fax 49 251 6099368
25. r professional trade association Be sure to observe the information on safety and health at work published by the professional trade association especially PTA information on Laser Installations for Shows and Projections Operation of Laser Installations and Regulations Pertaining to the Prevention of Accidents Laser Radiation Also observe the DIN regulations on the Safety of Laser Installations and Show Lasers and Show Laser Installations Requirements and Inspection as well as Shielding of Laser Work Places Technical Safety Requirements and Inspection The laser must never be operated without supervision The laser s operating console must not be located within the show laser s perimeter The laser must only be operated within an enclosed show laser perimeter Never direct the laser beam toward individuals or animals Secure the laser by all means against an unintentional alteration of the position Der Laser muss so ausgerichtet werden dass es keinesfalls zu einem Auswandern des Laserstrahls kommen kann Der Laser ist nicht f r Dauerbelastung konzipiert Benutzen Sie den Laser keinesfalls l nger als 4 Stunden Der Laser darf nur von daf r ausgebildeten Fachleuten betrieben und ber wacht werden Der Laser darf keinesfalls von Privatpersonen betrieben werden Die unterwiesene Person muss den Strahlengang berwachen und ggfs das Ger t abschalten Der Unternehmer muss daf r sor
26. t a minimum height of 3 5 mtr The laser must only be projected within the show laser perimeter The show laser perimeter is a danger zone that results from the operation of the show laser Stipulated limitations may be exceeded in this zone This area must be unattainable for unauthorised individuals The show laser perimeter must only be accessed when absolutely neces sary and while observing the safety measures The limits for radiation must never be exceeded for the auditorium The show laser perimeter must be measured and calculated prior to ope ration Keep the laser zone as small as possible Die Strahlung darf nicht weiter reichen als notwendig Um den Laser zu justieren m ssen Sie zun chst die Feststellschrauben am Installationsarm l sen und den Laser in die gew nschte Ausrichtung brin gen Spielen Sie nun alle Abbildungsmuster des Lasers durch um sicherzustel len das s mtliche Muster nur in den Showlaserbereich projeziert werden berpr fen Sie auch ob sich spiegelnde oder gl nzende Oberfl chen im Projektionsbereich des Lasers befinden z B Spiegelkugeln Entfernen Sie ggfs spiegelnde und strahlablenkende Gegenst nde Ziehen Sie danach die Feststellschrauben wieder gut fest Der Laserstrahl darf sich keinesfalls ohne den Einsatz von Werkzeug verstellen lassen 8 Betrieb ACHTUNG GESUNDHEITSRISIKO AAA Radiation must never extend further than necessary To adjust the laser first loosen the fix
27. uben Sie niemals das Geh use auf Es befindet sich eine Laserdiode im Ger t Stellen Sie bei Installation Betrieb Transport und Lagerung des Produktes stets sicher dass keine Ersch tterungen oder sonstige Gewalteinwirkungen auf das Geh use einwirken k nnen Das Geh use darf nur schwebend ber den Installationsarm montiert wer den Das Ger t muss immer mit einem geeigneten Sicherheitsfangseil gesichert werden Das Geh use darf w hrend des Betriebs keine anderen Ger te oder Gegenst nde ber hren Leicht entflammbare Materialien wie z B Dekorationsmaterialien und andere Gegenst nde und Fl chen m ssen mindestens 1 m vom Geh use entfernt sein Es muss immer eine einwandfreie Luftzirkulation stattfinden Ber hren Sie w hrend des Betriebs das Geh use nicht es erhitzt sich Erst ca 5 Minuten nach Ende des Betriebs k nnen Sie das Geh use wieder ber hren Es darf keinerlei Fl ssigkeit in das Geh use eindringen da dies die Schutzisolierung reduzieren oder Kurzschl sse ausl sen k nnte was zu t dlichen Stromschl gen f hren kann Im Fall von eingedrungener Fl ssigkeit m ssen Sie sofort den Netzstecker ziehen das Produkt gegen unbeabsichtigten Betrieb sichern und sich mit Ihrem Fachh ndler in Verbindung setzen Sch den die durch Fl ssigkeiten im Geh use entste hen sind von der Gew hrleistung ausgeschlossen Es d rfen keine Metallteile oder sonstige Gegenst nde in das Geh use gelangen da dies d
28. uct is a show laser with visible radiation at a wavelength of 532 nm This laser is intended exclusively for professional use to create lighting effects in the entertainment segment The product is connected to mains This product is designed for 230 V 50 Hz A C operation and exclusively for indoor use If used for any purpose other than described in these operating instruc tions the device may suffer damage and the warranty expires Also any other use is linked with risks such as short circuits fire electrical shock etc In addition there may also be exposure to dangerous rays The manufacturer s serial number must never be removed as otherwise the warranty expires This is a Class 3B laser according to the DIN EN 60 825 1 laser classifica tion Class 3B stipulates Laser radiation is dangerous to the eye and in par ticular cases also to the skin Class 3B lasers require a license ATTENTION Risk from laser radiation Eyes and skin must never be directly exposed to laser radiation Laser radiation may damage the eyes and skin Please observe all safety measures and regulations pertaining to the use of the laser Sicherheitshinweise Die Sicherheitshinweise speziell f r den Laserbetrieb in dieser Bedienungsanleitung beziehen sich auf den Geltungsbereich in der Bundesrepublik Deutschland F r andere L nder m ssen Sie die jeweiligen Sicherheitsbestimmungen bei Ihren Beh rden erfragen Scanic haftet nicht f r
29. vent of failure of the main fixture that no assembly parts can fall down The lighting effect unit must be attached via a certified hook to a tie bar system It must be ensured that an expert inspects the mechanical and safety rele vant installation prior to the initial operation and following major modifica tions prior to the renewed operation It must be ensured that an expert inspects the mechanical and safety rele vant installation at least once a year It must be ensured that an expert inspects the mechanical installation and the installation of relevance to safety within the framework of an accep tance test at least every four years The installation fixture must be as such that it can withstand 10 times the load capacity for a period of 60 minutes without harmful deformation It is prohibited for any individual to unnecessarily stay or pass beneath the installation during any type of assembly work The lighting effect unit must be secured by a safety arrester cable if fly mounted The cable must withstand 12 times the weight of the lighting effect unit Use arrester cables equipped with quick closing links The drop ping distance must not exceed 20 cm Defect arrester cables or arrester cables that have already been exposed to stress must not be used When choosing the location for the installation the auditorium and show laser perimeter must be defined in advance Install the laser as such that its projections occur a
30. x z dA d Ua Bedienungsanleitung Rancrnmgo0G ve Operating Instructions N ie RayGun 306 Wir gratulieren Ihnen zum Kauf des Scanic RayGun 30G Vielen Dank dass Sie unserer Technologie Ihr Vertrauen schenken Dieses Produkt erf llt die Anforderungen der geltenden europ ischen und nationalen Richtlinien die Konformit t wurde nachgewiesen die entspre chenden Erkl rungen und Unterlagen sind beim Hersteller hinterlegt Dieses Produkt entspricht der Schutzklasse und ist mit einer Schutzisolierung versehen Aus Sicherheits und Zulassungsgr nden CE ist das eigenm chtige Umbauen und oder Ver ndern des Produktes nicht gestattet Beachten Sie bitte dass Sch den die durch manuelle Ver nderungen an diesem Ger t verursacht werden nicht unter den Gew hrleistungsanspruch fallen Dieses Produkt ist ab Werk in einem einwandfreien Zustand Beachten Sie unbedingt alle Hinweise in dieser Bedienungsanleitung um diesen Zustand und einen gefahrlosen Betrieb des Produktes zu gew hrleisten Durch Nichtbeachtung dieser Bedienungsanleitung verursachte Sch den lassen jeden Gew hrleistungsanspruch erl schen F r Sach oder Personensch den die durch unsachgem e Handhabung des Produktes oder Nichtbeachtung der Bedienungsanleitung verursacht werden ber nimmt der Hersteller keine Haftung Heben Sie diese Bedienungsanleitung f r sp tere Fragen und Probleme gut auf und geben Sie sie bei Verkauf Verleih oder sonstiger ber