PeakTech_3730
Contents
1. www peaktech eu
2. Check test leads and probes for faulty insulation or bare wires before connection to the equipment To avoid electric shock do not operate this product in wet or damp conditions Conduct measuring works only in dry clothing and rubber shoes i e on isolating mats Never touch the tips of the test leads or probe Comply with the warning labels and other info on the equipment Always start with the highest measuring range when measuring unknown values Do not subject the equipment to direct sunlight or extreme temperatures humidity or dampness Do not subject the equipment to shocks or strong vibrations 18 Do not operate the equipment near strong magnetic fields motors transformers etc Keep hot soldering irons or guns away from the equipment Allow the equipment to stabilize at room temperature before taking up measurement important for exact measurements Do not input values over the maximum range of each measurement to avoid damages of the meter Replace the battery as soon as the battery indicator BAT appears With a low battery the meter might produce false reading that can lead to electric shock and personal injury Fetch out the battery when the meter will not be used for long period Periodically wipe the cabinet with a damp cloth and mid detergent Do not use abrasives or solvents The meter is suitable for indoor use only Do not operate the meter before the cabinet has been closed and screwed safely a
3. between the testing clips and the circuit under test and remove the testing clips away from the input terminals of the Meter 5 7 Transistor hFE Measurement Tom 1 2 easure transistor set up the Meter as follows Check that the transistor is PNP or NPN type Insert the transistor to be measured to the corresponding Transistor Jack The Meter displays the tested transistor s nearest value 30 Note z When transistor measurement has been completed disconnect the connection between the testing clips and the circuit under test and remove the testing clips away from the input terminals of the Meter 6 Maintenance of the unit WARNING Remove all the test leads before changing battery 6 1 Battery Replacement WARNING To avoid false readings which could lead to possible electric shock or personal injury replace the battery as soon as the battery indicator 5 appears To replace the battery 1 Turn the Meter power off and remove all connections from the terminals 2 Remove the screw from the battery compartment and separate the battery compartment from the case bottom 3 Remove the battery from the battery compartment 4 Replace the battery with a new 9V battery NEDA 1604 6F22 or 006P 31 5 Rejoin the case bottom and battery compartment and reinstall the screw Batteries which are used up dispose duly Used up batteries are hazardous and must be given in the for this bein
4. im Anzeigefeld des Messger tes ablesen HINWEISE Der Eigenwiderstand der Pr fleitungen kann bei Messungen von kleinen Widerst nden 200 Q Bereich die Genauigkeit der Messung negativ beeintr chtigen Der Eigenwiderstand blicher Pr fleitungen liegt zwischen 0 2 1 Q Zur genauen Bestimmung des Eigenwiderstandes Pr fleitungen an die Eingangsbuchsen des Multimeters anschlie en und Messspitzen kurzschlie en F r hohe Widerstandswerte gt 1MQ ist es normal dass die Anzeige einige Sekunden ben tigt bis sich der Messwert stabilisiert hat 5 5 Dioden Test ACHTUNG Keine externen Spannungsquellen an die Eingangsbuchsen anschlieBen Bei Anschluss externer Spannungsquellen besteht die Gefahr der Besch digung des Ger tes 11 Diese Funktion erm glicht die berpr fung von Dioden und anderen Halbleitern auf Durchl ssigkeit und Kurzschl sse Ebenfalls erlaubt diese Funktion die Durchlassspannung von Dioden zu ermitteln 1 Mit dem Funktions Bereichswahlschalter auf Stellung drehen 2 Rote Pr fleitung an den Q gt Eingang und schwarze Pr fleitung an den COM Eingang anschlie en 3 Pr fleitungen ber die zu messende Diode anlegen und Messwert in der LCD Anzeige ablesen Hinweise beachten HINWEISE Wenn in der LCD Anzeige ein Messwert angezeigt wird z B 0 2 bei einer Germaniumdiode oder 0 5 bei einer Siliziumdiode Polung der Pr fleitungen ndern Wird berlauf angezeigt ist
5. than 10 Q 3 5 Transistor Test Range Resolution Test Overload condition protection hFE 1B Vo 5 8V 250V ms Ibo 10A Remarks Display read approx hFE 0 1000 or transistor under test all types 23 4 Front View LCD Display L C switch Transistor Jack Resistance Diode and Continuity Buzzer Input Terminal Capacitance and Inductance Input Terminal Small Value Capacitance and Inductance Jack Rotary Switch Power Button ONOARWAN 24 4 1 Display Symbol SEAN al ae r a Symbol Meaning Transistor test Negative polarity indicator The battery is low WARNING To avoid false readings which could lead to possible electric shock or personal injury replace the battery as soon as the battery indicator appears Diode test 5 Continuity test 25 5 Operation 5 1 General instructions However electrical noise or intense electromagnetic fields in the equipment may disturb the measurement circuit Measuring instruments will also respond to unwanted signals that may be present within the measurement circuit Users should exercise care and take appropriate precautions to avoid misleading results when making measurements in the presence of electronic interference 5 2 Capacitance WARNING Discharge capacitor before trying to measure it 1 Set the Function Range switch to the desired ran
6. Gewicht mitgeliefertes Zubeh r 9 V Blockbatterie NEDA 1604 0 C 40 C bei einer Luftfeuchtigkeit von lt 70 20 C 50 C bei einer maximalen Luftfeuchtigkeit von 75 Batterie aus dem Batteriefach entfernen 172 x 83 x 38 mm ca 310g Pr fleitungen Batterie Anleitung 3 Messfunktionen 3 1 Kapazit tsmessungen Bereich Aufl sung Genauigkeit Testfrequenz 2nF 1 pF 20 nF 10 pF 1 0 v M 5 St 1 kHz 150 mV 200 nF 100 pF 2 uF 1 nF 20 uF 10 nF 4 0 v M 5 St aaa EF rt 100 Hz 15 mV 600 uF 1 uF nur Referenz 100 Hz 1 5 mV berlastschutz 0 315 A 250 V Sicherung 4 L sst sich die Anzeige nicht auf Null stellen so ist der angezeigte Wert bei offener Schaltung vom Kapazit tswert abzuziehen um den korrekten Messwert zu erhalten 3 2 Induktivit tsmessungen Bereich Aufl sung Genauigkeit Testfrequenz 2 mH 0 001 mH 20 mH 0 01 mH 2 v M 8 St 1KHz 150uA 200 mH 01 mH 2 H 0 001 H 5 v M 5 St 20 H 0 01 H 5 v M 15 St 100Hz 15A berlastschutz 0 315A 250V Sicherung 3 3 Widerstandsmessungen Bereich Aufl sung Genauigkeit berlastschutz 200 Q 0 1 Q 0 8 v M 3 St 2 kQ 1 Q 20 kQ 10 Q 0 8 vM 1 200 ko 100 no St 250 Ver 2 MQ 1 kQ 20 MQ 10 kQ 2 0 v M 5 St Der Eigenwiderstand der Pr fleitungen kann bei Mess
7. PeakTech Pr f und Messtechnik ip Spitzentechnologie die iberzeugt PeakTechk 3730 Bedienungsanleitung Manual Induktivit ts Kapazit tsmessger t Inductance Capacitance Tester 1 Sicherheitshinweise Dieses Ger t erf llt die EU Bestimmungen 2004 108 EG elektromagnetische Kompatibilit t und 2006 95 EG Nieder spannung entsprechend der Festlegung im Nachtrag 2004 22 EG CE Zeichen berspannungskategorie Il Verschmutzungsgrad 2 Zur Betriebssicherheit des Ger tes und zur Vermeidung von schweren Verletzungen durch Strom oder Spannungs berschl ge bzw Kurzschl sse sind nachfolgend aufgef hrte Sicherheitshinweise zum Betrieb des Ger tes unbedingt zu beachten Sch den die durch Nichtbeachtung dieser Hinweise entstehen sind von Anspr chen jeglicher Art ausgeschlossen maximal zul ssige Eingangswerte unter keinen Umst nden berschreiten schwere _Verletzungsgefahr und oder Zerst rung des Ger tes Nehmen Sie das Ger t nie in Betrieb wenn es nicht v llig geschlossen ist Defekte Sicherungen nur mit einer dem Originalwert entsprechenden Sicherung ersetzen Sicherung oder Sicherungshalter niemals kurzschlie en Vor dem Umschalten auf eine andere Messfunktion Pr fleitungen oder Tastkopf von der Messschaltung abkoppeln Keine Spannungsquellen ber die Eing nge anlegen Bei Nichtbeachtung droht Verletzungsgefahr und oder die Gefahr der Besch digung des Multimeters Ger t Pr fleit
8. ce the red test clip on the component s anode and place the black test clip on the component s cathode The display shows the diode forward voltage drop s nearest value In a circuit a good diode should still produce a forward voltage drop reading of 0 5 V to 0 8 V however the reverse voltage drop reading can vary depending on the resistance of other pathways between the probe tips Connect the test clips to the proper terminals as said above to avoid error display The LCD will display 1 indicating open circuit for wrong connection The unit of diode is Volt V displaying the positive connection voltage drop value When diode measurement has been completed disconnect the connection between the testing clips and the circuit under test and remove the testing clips and the circuit under test and remove the testing clips away from the input terminals of the Meter 29 5 6 Testing for Continuity To test for continuity connect the Meter as below 5 Note Insert the red test clip into the Q gt terminal and the black test clip into the COM terminal Set the rotary switch to Pt Connect the test clips across with the object being measured The beeper comes on continuously when the test resistance lt 120 Q The Meter displays the value of the test resistance The LCD displays 1 indicating the circuit being tested is open When continuity test has been completed disconnect the connection
9. der Vervielf ltigung dieser Anleitung oder Teilen daraus vorbehalten Reproduktionen jeder Art Fotokopie Mikrofilm oder ein anderes Verfahren nur mit schriftlicher Genehmigung des Herausgebers gestattet Letzter Stand bei Drucklegung Technische nderungen des Ger tes welche dem Fortschritt dienen vorbehalten Hiermit best tigen wir dass alle Ger te die in unseren Unterlagen genannten Spezifikationen erf llen und werkseitig kalibriert geliefert werden Eine Wiederholung der Kalibrierung nach Ablauf von 1 Jahr wird empfohlen PeakTech 03 2012 Ho 17 1 Safety Precautions This product complies with the requirements of the following European Community Directives 2004 108 EC Electromagnetic Compatibility and 2006 95 EC Low Voltage as amended by 2004 22 EC CE Marking Overvoltage category II pollution degree 2 To ensure safe operation of the equipment and eliminate the danger of serious injury due to short circuits arcing the following safety precautions must be observed Damages resulting from failure to observe these safety precautions are exempt from any legal claims whatever Do not exceed the maximum permissible input ratings danger of serious injury and or destruction of the equipment Replace a defective fuse only with a fuse of the original rating Never short circuit fuse or fuse holding Disconnect test leads or probe from the measuring circuit before switching modes or functions
10. die Diode durchg ngig und in Ordnung Der angezeigte Wert entspricht dem Durchlasswiderstand des Bauteils bis zu 2 0 V Bei berlaufanzeige im Display ist die Diode defekt oder die Pr fleitungen sind falsch gepolt Wird in der Anzeige ein Wert angezeigt ist die Diode durchg ngig und in Ordnung Der an gezeigte Wert entspricht dem Durchlasswiderstand des Bauteils bis zu 2 0 V Wird ein Wert sowohl vor als auch nach dem Vertauschen der Polarit t angezeigt ist das Bauteil kurzgeschlossen und defekt 12 5 6 Durchgangspr fung 1 Funktions Bereichswahlschalter in Stellung gt F drehen 2 Rote Pr fleitung an den o Eingang und schwarze Pr fleitung an den COM Eingang des Ger tes anschlie en 3 Zu messende Schaltung spannungslos schalten 4 Pr fleitungen ber das zu messende Bauteil bzw die zu messende Schaltung anlegen Bei Widerst nden unter 40 Q Bauteil durchg ngig ert nt ein akustisches Signal ACHTUNG Unter keinen Umst nden Durchgangspr fungen an spannungs f hrenden Bauteilen oder Schaltungen vornehmen 5 7 Transistortest dz 2 Funktionswahlschalter in Stellung hFE drehen Transistortyp NPN PNP bestimmen Ermitteln Sie denEmitter Basis und Collector Anschluss Setzen Sie diese Anschl sse in die entsprechenden L cher der Buchse auf der Frontseite des Ger tes ein 6 Wartung des Ger tes ACHTUNG Vor dem Auswechseln der Batterie alle Pr fleitungen von den Ein
11. er letzten Seite angegeben Adresse unentgeltlich zur ckgeben oder ausreichend frankiert per Post an uns zur cksenden Batterien die Schadstoffe enthalten sind mit dem Symbol einer durchgekreuzten M lltonne gekennzeichnet hnlich dem Symbol in der Abbildung links Unter dem M lltonnensymbol befindet sich die chemische Bezeichnung des Schadstoffes z B CD f r Cadmium Pb steht f r Blei und Hg f r Quecksilber Weitere Hinweise zur Batterieverordnung finden Sie beim Bundesministerium fur Umwelt Naturschutz und Reaktorsicherheit 15 6 2 Auswechseln der Sicherung Ist das Ger t nicht betriebsbereit Sicherung berpr fen Dazu wie folgt verfahren 1 Alle Pr fleitungen von den Eingangsbuchsen des Ger tes abziehen 2 Schutzholster vom Ger t abziehen 3 Schraube des Batteriefaches l sen Batteriefach abziehen und Batterie entnehmen 4 Die 3 Geh useschrauben l sen und Geh useunterteil abnehmen 5 Sicherung aus dem Sicherungshalter entnehmen und berpr fen 6 Sicherung ggf durch eine neue Sicherung ersetzen und wieder in den Sicherungshalter einsetzen 7 Geh useunterteil wieder aufsetzen und mit den 3 Schrauben sichern 8 Batterie einsetzen und Batteriefach mit der Schraube befestigen ACHTUNG Defekte Sicherung nur mit einer dem Originalwert entsprechenden Sicherung ersetzen 0 315 A 250 V 16 Alle Rechte auch die der bersetzung des Nachdruckes und
12. erner Spannungsquellen an die Eingangsbuchsen besteht die Gefahr der Besch digung des Ger Zur 1 HIN tes Messung von Induktivit t wie beschrieben verfahren Mit dem Funktions Bereichswahlschalter gew nschten Widerstandsbereich w hlen Umschalter L C durch Dr cken bzw L sen in die L Position bringen Rote Pr fleitung in die Lx Eingang und schwarze Pr fleitung in den Lx Eingang Pr fleitungen ber die zu messende Induktivit t anlegen und Messwert in der LCD Anzeige des Messger tes ablesen WEIS Vor der Messung von Induktivit ten im 2mH Bereich sollten die Pr fleitungen kurzgeschlossen werden Der bei kurzgeschlossenen Pr fleitungen angezeigte Messwert muss dann bei der Induktivit tsmessungen vom Messwert subtrahiert werden Das Messger t kann nicht die Qualit t der Induktivit t ermitteln Nach erfolgter Messung trennen Sie die Pr fspitzen vom Messkreis und entfernen Sie die Pr fleitungen vom Messger t 10 5 4 Widerstandsmessungen ACHTUNG Keine externen Spannungsquellen an die Eingangsbuchsen anschlie en Bei Anschluss externer Spannungsquellen an die Eingangsbuchsen besteht die Gefahr der Besch digung des Ger tes 1 Mit dem Funktions Bereichswahlschalter gew nschten Widerstandsbereich w hlen 2 Rote Pr fleitung an den Q gt H Eingang und schwarze Pr fleitung an den COM Eingang 3 Pr fleitungen ber den zu messenden Widerstand anlegen und Messwert
13. external voltage to the sockets damage to the meters may result 1 Set the Function Range switch to the desired range 2 Insert the red test lead into Q SS socket and the black test lead into COM socket 3 Read the resistance directly from the display The resistance in the test leads can diminish accuracy on the lowest 200 Q range The error is usually 0 1 to 0 2 Q for a standard pair of test leads To determine the error short the test leads together and then use the REL Relative mode to automatically subtract the lead resistance from resistance measurements For high resistance measurement gt 1MQ it is normal taking several seconds to obtain a stable reading 5 5 Diode Test WARNING To avoid damages to the Meter or to the devices under test disconnect circuit power and discharge all the high voltage capacitors before measuring diodes and continuity Testing Diodes Use the diode test to check diodes transistors and other semiconductor devices The diode test sends a current through the semiconductor junction And then measures the voltage drop across the junction A good silicon junction drops between 0 5 V and 0 8 V 28 To test a diode out of a circuit connect the Meter as follows Note Insert the red test clip into the Q gt terminal and the black test clip into the COM terminal Set the rotary switch to F 9 For forward voltage drop readings on any semiconductor component pla
14. g ngen abziehen 13 6 1 Auswechseln der Batterie Das Ger t arbeitet mit einer 9 V Blockbatterie Bei ungen gender Batteriespannung leuchtet das Batteriesymbol in der LCD Anzeige des Ger tes auf und die Batterie ist dann baldm glichst auszuwechseln Dazu wie beschrieben verfahren 1 Die Schraube an der R ckseite des Ger tes l sen und Batteriefachdeckel abnehmen 2 Verbrauchte Batterie aus dem Batteriefach entnehmen 3 Neue Batterie in das Batteriefach einsetzen 4 Geh usedeckel wieder auflegen und mit der Schraube befestigen ACHTUNG Verbrauchte Batterien ordnungsgem entsorgen Verbrauchte Batterien sind Sonderm ll und m ssen in die daf r vorgesehenen Sammelbeh lter gegeben werden 14 Gesetzlich vorgeschriebene Hinweise zur Batterieverordnung Im Lieferumfang vieler Ger te befinden sich Batterien die z B zum Betrieb von Fernbedienungen dienen Auch in den Ger ten selbst k nnen Batterien oder Akkus fest eingebaut sein Im Zusammenhang mit dem Vertrieb dieser Batterien oder Akkus sind wir als Importeur gem Batterieverordnung verpflichtet unsere Kunden auf folgendes hinzuweisen Bitte entsorgen Sie Altbatterien wie vom Gesetzgeber vorgeschrieben die Entsorgung im Hausm ll ist laut Batterieverordnung ausdr cklich verboten an einer kommunalen Sammelstelle oder geben Sie sie im Handel vor Ort kostenlos ab Von uns erhaltene Batterien k nnen Sie nach Gebrauch bei uns unter der auf d
15. g procedure To replace the Meter s fuse 1 Turn the Meter power off and remove all connections from the terminals 2 Remove the screw from the battery compartment and separate the battery compartment from the case bottom 3 Remove the screws from the case bottom and separate the case top from the case bottom 4 Remove the fuse by gently prying one end loose then take out the fuse from its bracket 33 5 Install ONLY replacement fuses with the identical type and specification as follows and make sure the fuse is fixed firmly in the bracket Fuse 1 0 315 A 250 V fast type fuse 5 x 20 mm 6 Rejoin the battery compartment and the case top and reinstall the screw 7 Rejoin the case bottom and case top and reinstall the screws All rights also for translation reprinting and copy of this manual or parts are reserved Reproductions of all kinds photocopy microfilm or other only by written permission of the publisher This manual is according the latest technical knowing Technical changings which are in the interest of progress reserved We herewith confirm that the units are calibrated by the factory according to the specifications as per the technical specifications We recommend to calibrate the unit again after 1 year PeakTech 03 2012 Ho PeakTech Pr f und Messtechnik GmbH Kornkamp 32 DE 22926 Ahrensburg Germany 2 49 0 4102 42343 44 49 0 4102 434 16 B info peaktech de
16. g supposed collective container Statutory Notification about the Battery Regulations The delivery of many devices includes batteries which for example serve to operate the remote control There also could be batteries or accumulators built into the device itself In connection with the sale of these batteries or accumulators we are obliged under the Battery Regulations to notify our customers of the following Please dispose of old batteries at a council collection point or return them to a local shop at no cost The disposal in domestic refuse is strictly forbidden according to the Battery Regulations You can return used batteries obtained from us at no charge at the address on the last side in this manual or by posting with sufficient stamps 32 Batteries which contain harmful substances are marked with the symbol of a crossed out waste bin similar to the illustration shown left Under the waste bin symbol is the chemical symbol for the harmful substance e g Cd for cadmium Pb stands for lead and Hg for mercury You can obtain further information about the Battery Regulations from the Bundesministerium f r Umwelt Naturschutz und Reaktorsicherheit Federal Ministry of Environment Nature Conservation and Reactor Safety 6 2 Replacing the Fuse WARNING To avoid electrical shock or arc blast or personal injury or damage to the Meter use specified fuses ONLY in accordance with the followin
17. ge 2 Press L C switch to activate C Function 3 Insert the test leads directly into the socket or test leads socket CX 4 Read the capacitance directly from the display NOTE In lower range substract residual offset reading from the result with test leads opening WARNING Never apply an external voltage to socket damage to the meter may result 26 5 3 Inductance Measurement To 1 2 RE test the inductance please follow the following procedure Set the rotary switch to LX measurement mode If the tested inductance value is unknown use the maximum measurement position and decrease the range step by step until a satisfactory reading is obtained Insert the test clips into the corresponding Lx input terminals Use the test clips to clip the inductance to carry out the testing The measured value shows on the display MARKS When carrying out measurement at 2 mH short circuit the test clip first then carrying out the measurement The actual correct reading is the measure reading minus the short circuit reading When testing a small value inductance it is better to use the small value jack The Meter cannot check the quality of the inductance When inductance measurement has been completed disconnect the connection between the testing clips and the circuit under test and remove the testing clips away from the input terminals of the Meter 27 5 4 Resistance WARNING Never apply an
18. offtuch und einem milden Reinigungsmittel Benutzen Sie keine tzenden Scheuermittel Dieses Ger t ist ausschlie lich f r Innenanwendungen geeignet Vermeiden Sie jegliche N he zu explosiven und entflammbaren Stoffen ffnen des Ger tes und Wartungs und Reparaturarbeiten d rfen nur von qualifizierten Service Technikern durchgef hrt werden 2 Ger t nicht mit der Vorderseite auf die Werkbank oder Arbeitsfl che legen um Besch digung der Bedienelemente zu vermeiden Keine technischen Ver nderungen am Ger t vornehmen Messger te geh ren nicht in Kinderh nde Reinigung des Ger tes Ger t nur mit einem feuchten fusselfreien Tuch reinigen Nur handels bliche Sp lmittel verwenden Beim Reinigen unbedingt darauf achten dass keine Fl ssigkeit in das Innere des Ger tes gelangt Dies k nnte zu einem Kurzschluss und zur Zerst rung des Ger tes f hren 2 Technische Daten Anzeige 3 stellige 21 mm LCD Anzeige max Anzeige 1999 Polarit t automatische Umschaltung Anzeige des Minussymbols bei negativen Messwerten berbereichs anzeige 1 wird angezeigt Nullabgleich automatisch Batteriezustands anzeige Batteriesymbol erscheint bei ungen gender Batteriespannung Messfolge 2 5 x pro Sekunde Genauigkeit gemessen bei 23 C 5 C und einer Luftfeuchtigkeit von lt 75 3 Spannungsver sorgung Betriebstempe raturbereich Lagertempe raturbereich Abmessungen HxBxT
19. s terminal can carry voltage Do not store the meter in a place of explosive inflammable substances Do not modify the equipment in any way Opening the equipment and service and repair work must only be performed by qualified service personnel Measuring instruments don t belong to children hands Cleaning the cabinet Clean only with a damp soft cloth and a commercially available mild household cleanser Ensure that no water gets inside the equipment to prevent possible shorts and damage to the equipment 19 2 Specifications Display Polarity Overrange Zero Low Battery Indication Measurement Rate Accuracy Power Operating Environment Storage Temperature Dimensions HxWxD 3 digit 21 mm liquid crystal LCD with a maximum reading of 1999 automatic positive implied negative polarity indication 1 is displayed automatic the battery symbol is displayed when the battery voltage drops below the operating level 2 5 times per second nominal stated accuracy at 23 C 5 C lt 75 relative humidity 9 Volt battery NEDA 1604 0 C to 40 C at lt 70 relative humidity 20 C to 50 C at max 75 relative humidity battery must be removed from meter 172 x 83 x 38 mm 20 Weight Accessories approx 310 g 3 Measuring Functions 3 1 Capacitance Test leads battery operation manual Range Resolution Accuracy
20. testing frequency 2nF 1pF 20nF 10pF 1 0 v M 5 St 1 kHz 150 mV 200 nF 100 pF 2 uF 1 nF 20 uF 10 nF 4 0 v M 5 St 200 uF 100 nF 100 Hz 15 mV 600 uF 1 uF Reference only 100 Hz 1 5 mV Overload protection 0 315A 250V fuse If the meter cannot adjust to zero you could use the tested values minus the open circuit value to get the correct measurement values 21 3 2 Inductance Range Resolution Accuracy Tested Frequency Current 2mH 0 001 mH 20 mH 0 01 mH 2 v M 8 St 1kHz 150uA 200 mH 0 1 mH 2H 0 001 H 5 v M 5 St 20 H 0 01 H 5 v M 15 St 100Hz 15uA Overload protection 0 315A 250V fuse 3 3 Resistance Range Resolution Accuracy Overload Protection 200 Q 0 1 Q 0 8 v M 3 St 2 kQ 1 Q lt a 2 0 8 v M 1 St 250 Ver 2 MQ 1 kQ 20 MQ 10 kQ 2 0 v M 5 St When you short the test leads in the 200 Q range your meter displays a small value no more than 0 3 Q This value is due to your meters and test leads internal resistance Make a note of this value and subtract it from small resistance measurements for better accuracy 22 3 4 Continuity and Diodes Function Range Resolution Overload Protection Diode gt F 1mV 25V Continuity 19 Remarks Diode Leerlaufspannung 5 8V Forward current 1mA Continuity Audible continuity threshold Less
21. tor Test Negativ Indikator Batteriezustandsanzeige Batterie ist Leer Warnung Mangelnde Batterieleistung kann un pr zise Messergebnisse hervorrufen Stromschl ge und k rperliche Sch den k nnen die Folge sein Dioden Test Durchgangspr fung 5 Messbetrieb 5 1 Allgemeines Genaue Messergebnisse setzen entsprechende Messbe dingungen voraus Bitte beachten Sie dass Messungen in der N he von elektromagnetischen Feldern oder starken elektrischen St rfeldern das Messergebnis negativ beeintr chtigen k nnten 5 2 Kapazit tsmessungen ACHTUNG Kondensator vor der Messung unbedingt entladen 1 Mit dem Funktions Bereichswahlschalter gew nschten Kapazit tsbereich w hlen 2 Umschalter L C durch dr cken bzw l sen in C Position bringen 3 Kondensator in bereinstimmung mit den und Markierungen an den Kondensatorpr fbuchsen in die Pr fbuchsen einstecken bzw CX benutzen 4 Kapazit tswert im Anzeigefeld des Messger tes ablesen HINWEIS Beim Messen geringer Kapazit tswerte Offset Wert der Pr fleitungen von der Messwertanzeige abziehen ACHTUNG Keine externen Spannungsquellen an die Kondensator pr fbuchsen anschlie en Bei Anschluss externer Spannungsquellen besteht die Gefahr der Besch digung des Ger tes 9 5 3 Induktivit tsmessungen ACHTUNG Keine externen Spannungsquellen an die Eingangsbuchsen ans chlie en Bei Anschluss ext
22. ungen von kleinen Widerst nden 200 Q Bereich die Genauigkeit der Messung negativ beeintr chtigen Der Eigenwiderstand blicher Pr fleitungen liegt zwischen 0 2 1 Q Zur genauen Bestimmung des Eigenwiderstandes Pr fleitungen an die Eingangsbuchsen des Multimeters anschlie en und Messspitzen kurzschlie en Der angezeigte Messwert entspricht dem Eigenwiderstand der Pr fleitungen 3 4 Diodentest und Durchgangspr fung Funktion Bereich Aufl sung berlastschutz Diode 1mV 250V ms Durchgangspr fung y 10 Hinweis Diode Leerlaufspannung 5 8V Teststrom 1mA Durchgangspr fung Summer ert nt bei einem Widerstand lt 10Q 3 5 Transistor Test Bereich Aufl sung Testbedingungen berlastschutz Vo 5 8V hufe 1p lo 104A 250Verr Hinweis Anzeige zeigt ungefahr den hFE Wert 0 1000 des getesteten Transistors alle Typen 4 Vorderansicht des Ger tes PoON gt a 8 2 ts 6 3 LCD Anzeige Taste zum Umschalten zwischen Kapazitat und Induktivitat Pr fbuchse f r Transistorpr fung Eingangsbuchsen f r Widerstands Dioden und Durch gangspr fung mit Summer Eingangsbuchsen f r Kapazit s und Induktivit ts messungen Einsteckbuchse f r Kapazit ts und Induktivit tsmessungen von einzelnen Bauteilen Funktions Bereichswahlschalter Ein Aus Taste afe 4 1 Anzeige Symbole nn ui Beschreibung Transis
23. ungen und sonstiges Zubeh r vor Inbetriebnahme auf eventuelle Sch den bzw blanke oder geknickte Kabel und Dr hte berpr fen Im Zweifelsfalle keine Messungen vornehmen 1 Messarbeiten nur in trockener Kleidung und vorzugsweise in Gummischuhen bzw auf einer Isoliermatte durchf hren Messspitzen der Pr fleitungen nicht ber hren Warnhinweise am Ger t unbedingt beachten Bei unbekannten Messgr en vor der Messung auf den h chsten Messbereich umschalten Ger t keinen extremen Temperaturen direkter Sonneneinstrahlung extremer Luftfeuchtigkeit oder N sse aussetzen Starke Ersch tterung vermeiden Ger t nicht in der N he starker magnetischer Felder Motoren Transformatoren usw betreiben Hei e L tpistolen aus der unmittelbaren N he des Ger tes fernhalten Vor Aufnahme des Messbetriebes sollte das Ger t auf die Umgebungstemperatur stabilisiert sein wichtig beim Transport von kalten in warme R ume und umgekehrt berschreiten Sie bei keiner Messung den eingestellten Messbereich Sie vermeiden so Besch digungen des Ger tes Ersetzen Sie die Batterie sobald das Batteriesymbol BAT aufleuchtet Mangelnde Batterieleistung kann unpr zise Messergebnisse hervorrufen Stromschl ge und k rperliche Sch den k nnen die Folge sein Sollten Sie das Ger t f r einen l ngeren Zeitraum nicht benutzen entnehmen Sie die Batterie aus dem Batteriefach S ubern Sie das Geh use regelm ig mit einem feuchten St