1. 11 1 Battery Replacement If the sign BAT appears on the LCD display it indicates that the battery should be replaced 1 Remove screw of the battery compartment 2 Replace the exhausted batteries with new batteries 3 Close battery compartment and fix the screws Batteries which are used up dispose duly Used up batteries are hazardous and must be given in the for this being supposed collective container 30 11 2 Statutory Notification about the Battery Regulations The delivery of many devices includes batteries which for example serve to operate the remote control There also could be batteries or accumulators built into the device itself In connection with the sale of these batteries or accumulators we are obliged under the Battery Regulations to notify our customers of the following Please dispose of old batteries at a council collection point or return them to a local shop at no cost The disposal in domestic refuse is strictly forbidden according to the Battery Regulations You can return used batteries obtained from us at no charge at the address on the last side in this manual or by posting with sufficient stamps Batteries which contain harmful substances are marked with the symbol of a crossed out waste bin similar to the illustration shown left Under the waste bin symbol is the chemical symbol for the harmful substance e g Cd for cadmium Pb stands for lead and Hg for mercur
2. Unterschiedliche Farbspektren von Lichtquellen w rden unterschiedliche Sensoren ben tigen um vergleichbare Messwerte der Beleuchtungsst rke erzielen zu k nnen Um dies zu umgehen k nnen Sie beim PeakTech 5086 neun verschiedene Korrekturfaktoren f r Lichtquellen einstellen und abspeichern welche bei der jeweils aktuellen Lichtquelle ausgew hlt werden k nnen Hierdurch wird der Wert welcher sich an einer herk mmlichen Gl hlampe mit 2856K orientiert um den eingestellten Faktor korrigiert Bsp Messwert 2000 Lux x Korrekturfaktor 0 8 Korrigierter Wert 1600 Lux 10 8 2 Auswahl der Lichtquelle Das PeakTech 5086 hat neun Speicherpl tze L1 bis L9 f r Korrekturfaktoren Der Standardfaktor f r die 2856K Leuchte ist 1 000 1 Halten Sie die HOLD L S Taste 9 gedr ckt und die Nummer der aktiven Lichtquelle L1 bis L9 f ngt an zu blinken 2 Bet tigen Sie die V A Pfeiltasten um eine andere Lichtquelle auszuw hlen 3 Dr cken Sie die HOLD L S Taste 9 f r ca 2 Sekunden um wieder in die normale Messfunktion mit der gew hlten Lichtquelle L1 bis L9 zu wechseln 8 3 ndern des Korrekturfaktors 1 Halten Sie die HOLD L S Taste 9 gedr ckt und die Nummer der aktiven Lichtquelle L1 bis L9 f ngt an zu blinken 2 Bet tigen Sie die V A Pfeiltasten um eine andere Lichtquelle auszuw hlen 3 Dr cken Sie die HOLD L S Taste 9 kurz um auf den eingestellten Korrekturfaktor zu wechseln
3. 2 Wenn Sie den gew nschten Messwert speichern wollen dr cken Sie kurz die MEM READ Taste 3 und das M Symbol f r Memory und eine kurze Info ber den Speicherplatz wird links oben in der Anzeige dargestellt Die Speicherung der Werte erfolgt fortlaufend von 01 bis 99 7 2 Aufrufen von Messwerten Messwerte werden als Lux oder Fc Wert mit jeweiliger Messeinheit gespeichert M chten Sie einen zuvor gespeicherten Messwert wieder anzeigen gehen Sie wie folgt vor 1 Schalten Sie das Messger t ein 2 Halten Sie die Taste MEM READ ca 2 Sekunden gedr ckt und in der oberen linken Ecke der Anzeige erscheint das R Symbol f r Read und der Speicherplatz des letzten gespeicherten Wertes welcher in der Hauptanzeige dargestellt wird 3 Schalten Sie die gespeicherten Messwerte ggf mit den VA Pfeiltasten durch 4 Um diese Funktion wieder zu verlassen halten Sie die MEM READ Taste f r ca 2 Sekunden gedr ckt 9 7 3 Messwertspeicher l schen Es kann nur der komplette Messwertspeicher gel scht werden Wenn der Messwertspeicher gel scht werden soll gehen Sie wie folgt vor 1 Schalten Sie das Messger t aus 2 Halten Sie die MEM READ Taste 3 gedr ckt und schalten das Messger t wieder ein 7 3 Es erscheint CLA in der Anzeige und der interne Speicher wird kompett gel scht 4 Das Ger t schaltet sich danach wieder ab 8 Lichtquellen und Korrekturfaktor 8 1 Lichtquellen
4. Different color spectra of light sources would require different sensors in order to obtain comparable measurements of the illuminance To get around this you can select and store nine different correction factors for light sources with the PeakTech 5086 which can be selected for the current light source Through this the measured value which is based on a conventional light bulb with 2856K and daylight LED correction is changed by the selected factor Example Measured value 2000 Lux x correction factor 0 8 Corrected value 1600 Lux 8 2 Selection of the light source The PeakTech 5086 has nine presets L1 to L9 for correction factors The default factor for the 2856K lamp is 1 000 1 Press and hold the HOLD LS key 9 and the number of active Light source L1 to L9 will start blinking 2 Press the A arrow buttons to select another light source 3 Press the HOLD LS key 9 for about 2 seconds to switch back to the normal measurement function with the selected light source L1 to L9 8 3 Change the correction factor 1 Press and hold the HOLD LS key 9 and the number of the active light source L1 to L9 starts to flash 2 Press the A arrow buttons to select another light source 26 3 Press the HOLD LS key 9 briefly to switch to the setting of the correction factor This will flash now 4 Change the correction factor according to the desired value with the A arrow keys 5 Save this va
5. Dieser blinkt nun auf 4 ndern Sie den Korrekturfaktor nach Wunsche mit den VA Pfeiltasten 5 Speichern Sie diesen Wert indem Sie die HOLD L S Taste 9 ca 2 Sekunden gedr ckt halten 6 Das Ger t zeigt nun den Korrekturfaktor L1 bis L9 an welchen Sie zuletzt bearbeitet haben 11 8 4 Tabelle der Korrekturfaktoren Lichtquelle Faktor CIE Standard Lichtquelle A 1 000 LED Tageslicht Wei 0 990 LED Rot 0 516 LED Gelb 0 815 LED Gr n 1 216 LED Blau 1 475 LED Lila 1 148 Neon Wei 0 870 Neon Blau 1 286 Neon Gr n 1 167 Neon Pink 0 760 Neon Lila 0 804 Neon Rot 0 671 Neon Gelb 0 840 8 5 Farb Korrekturfaktor CCF Wenn die gemessene Lichtquelle sich von der CIE Standard Lichtquelle A mit 2856K unterscheidet auf welche das PeakTech 5086 kalibriert ist tritt ein Messfehler aufgrund des spektralen Versatzes auf Dieser Fehler wird durch einen Farbkorrekturfaktor CCF korrigiert der wie folgt errechnet wird SAAN saN dA sa VA ar h A CCF S A ee FOER h SA VA dA ps SA dA 9 Empfohlene Beleuchtungsstarken 9 1 Einleitung Um ein sicheres Arbeiten zu gewahrleisten und die Anstrengung der Augen m glichst zu minimieren sollten die Arbeitsoberflachen wie B rotische Arbeitsplatten oder Arbeitsr ume im Allgemeinen ber eine gute Ausleuchtung verf gen welche aber gleichzeitig auch nicht blenden soll Hierf r gibt es Richtwerte wel
6. other light sources 30 2 60 6 80 25 One silicon photo diode with filter 10 C to 60 C 14 F to 140 F at lt 80 relative humidity 3 x 1 5 AAA Battery 60 x 115 x 30 mm W x H x D 58 x 160 x 27 mm W x Hx D 280 g 20 4 Panel Description Multi Line LC Display Battery compartment Rear Side MEM READ Button LX FC CD Button A Button Zero Button ON OFF Button Light Sensor HOLD L S Button Y Button A EE 21 5 Display Symbols 9 Light Source SSERBLEN 1 u u M v ULIL R for Reading and M for Memory Display of the memory location 1 99 Icon Auto Power Off active LX FC CD reading Active light source 1 9 Symbol HOLD MAX MIN or AVG Selected measuring unit Additional counts for larger measurements Battery indicator Correction factor of the light source Se OE D S 22 6 Operating Instruction 6 1 Lux Footcandle Measurement 1 Remove the protective cap from the photosensor 2 Switch on the unit via the ON OFF switch 7 3 In lux or footcandles change measurement unit by a short press of the LX FC CD button 4 4 Place photo sensor as vertical as possible under the measured light source or on the surface to be measured 5 Read measured value in the LCD display 6 After completion of the measurement put back protective cap on the sensor and switch off the unit 7 6 2 Photometry Candela 1 Remov
7. 2 5 Mal pro Sekunde Kosinuswinkel Korrektur Messung Klasse A JIS C 1609 1993 CNS 5119 Data Hold Min Max sowie AVG Messung Automatische Bereichswahl und Nullstellung 2 3 Technische Daten Anzeige berbereichsanzeige Batteriezustandsanzeige Messfolge Messbereiche Genauigkeit Winkelabweichung bei der Kosinus Charakteristik Fotosensor Lagertemperaturbereich Spannungsversorgung Abmessungen Fotosensor Gerateabmessungen Gewicht LCD Anzeige 4 stellig lt 10000 Lux 5 stellig gt 10000 Lux 6 stellig gt 100000 Lux OL Batteriesymbol leuchtet bei ungen gender Batteriespannung 2 5 x pro Sekunde typisch 40 400 4000 40000 400000 Lux 40 400 4000 40000 fc 3 kalibriert mit Standard 2856k Gl hlampe 6 andere Lichtquellen 30 2 60 6 80 25 Silicium Fotodiode mit Filter 10 60 C Luftfeuchtigkeit lt 80 3 x 1 5V Batterie AAA 60 x 115 x 30 mm BxHxT 58 x 160 x 27 mm BxHxT 280g 3 4 Bedienelemente und Anschl sse am Ger t Mehrzeilige LCD Anzeige Batteriefach R ckseite MEM READ Taste LX FC CD Taste zur Einheitenwahl A Taste zur Wertveranderung Zero Taste zur Nullstellung Ein Ausschalter Licht Sensor HOLD L S Taste V Taste zur Wertver nderung 4 EI 5 Anzeigesymbole 10 Anzeige R f r Lesen und M f r Speichern Anzeige des Speicherplatzes 1 99 Symbol Auto Power Off aktiv L
8. KOMETEC Karl Oelkers e K Mess und Pr fger te Shop Mozartstr 10 D 88097 Eriskirch T 07541 I 955 1313 F 07541 955 1131 info kometec de www kometec de PeakTech Pr f und Messtechnik Spitzentechnologie die berzeugt PeakTech 5086 Bedienungsanleitung Operation manual Digital LED LUX Messgerat Digital LED LUX Meter 1 Sicherheitshinweise zum Betrieb des Ger tes Dieses Ger t erf llt die EU Bestimmungen 2004 108 EG elektromagnetische Kompatibilit t entsprechend der Festlegung im Nachtrag 2004 22 EG CE Zeichen Verschmutzungsgrad 2 Vor Inbetriebnahme des Ger tes Bedienungsanleitung sorgf ltig lesen Nachfolgend aufgef hrte Sicherheitshinweise zum Betrieb des Ger tes sind unbedingt zu beachten Sch den die durch Nichtbeachtung dieser Hinweise entstehen sind von Anspr chen jeglicher Art ausgeschlossen Nehmen Sie das Ger t nie in Betrieb wenn es nicht v llig geschlossen ist Ger t vor Inbetriebnahme auf eventuelle Sch den bzw blanke oder geknickte Kabel und Dr hte berpr fen Im Zweifelsfalle keine Messung vornehmen Warnhinweise am Ger t unbedingt beachten Ger t keinen extremen Temperaturen direkter Sonneneinstrahlung extremer Luftfeuchtigkeit oder N sse aussetzen Starke Ersch tterungen vermeiden Ger t nicht in der N he starker magnetischer Felder Motoren Transformatoren usw betreiben Hei e L tpistolen aus der unmittelbaren Nahe des Ger tes
9. X FC CD Messwert Aktive Lichtquelle 1 9 Symbol HOLD MAX MIN oder AVG Ausgew hlte Messeinheit Zusatzstellen f r gr ere Messwerte Batterieanzeige Korrekturfaktor der Lichtquelle SEINEN 6 Messbetrieb 6 1 Lux Footcandle Messung 1 Schutzkappe vom Fotosensor entfernen 2 Ger t ber den Ein Ausschalter 7 einschalten 3 Messeinheit durch kurzen Tastendruck der LX FC CD Taste 4 auf Lux oder Footcandle ndern 4 Fotosensor m glichst senkrecht unter die zu messende Lichtquelle legen bzw auf die zu messende Oberfl che 5 Messwert in der LCD Anzeige ablesen 6 Nach Abschluss der Messung Schutzkappe wieder auf dem Sensor platzieren und Ger t ausschalten 7 6 2 Lichtst rkemessung Candela 1 Schutzkappe vom Fotosensor entfernen 2 Ger t ber den Ein Ausschalter 7 einschalten 3 Halten Sie die LX FC CD Taste 4 ca 2 Sekunden gedr ckt um auf Candela CD zu wechseln 4 In der Anzeige erscheint eine blinkende Einheit m oder ft der zu w hlenden Entfernung des Sensors zur Lichtquelle ndern Sie diesen Wert nach Bedarf durch die Pfeiltasten und best tigen Sie mit der LX FC CD Taste 4 5 Fotosensor m glichst senkrecht unter die zu messende Lichtquelle legen bzw auf die zu messende Oberfl che 6 Geben Sie die Entfernung des Sensors zur Lichtquelle mit den Pfeiltasten ein und best tigen Sie mit der LX FC CD Taste 4 6 7 Candela Messwert in der LCD Anze
10. che in der folgenden Tabelle nachgelesen werden k nnen 12 Zudem gibt es eine Vielzahl von Vorschriften nach verschiedenen Gewerben oder der Berufsgenossenschaften welche andere Werte f r genau spezifizierte T tigkeiten festhalten Diese k nnen Sie bei Ihrem Sicherheitsverantwortlichen oder direkt von den vorschriftsgebenden Institutionen erfahren 9 2 Empfehlungen Umgebung Arbeitsplatz Lux Wert B ros Empfangsr ume 200 750 allgemeine B rot tigkeiten 700 1500 Zeichenr ume arbeiten 1000 2000 Fabriken Fertigungsst tten Verpackungsr ume Eingangshallen 150 300 Visuelle Inspektionen im Produktionsbereich 300 750 Visuelle Inspektionen 750 1500 Elektronische Fertigungsb nder 1500 3000 Hotelbereich Aufenthaltsr ume 100 200 Empfangshallen Kassenbereich 200 1000 L den Kaufh user Innentreppen G nge 150 200 Schaufenster Verpackungstheken 750 1500 Bereich vor Schaufenstern 1500 3000 Krankenh user Krankenzimmer Lagerr ume 100 200 Untersuchungsr ume 300 750 Operationss le Intensivstation 750 1500 Schulen Auditorium Turnhallen 100 300 Klassenzimmer 200 750 Labors Zeichens le 500 1500 13 10 Spektrale Empfindlichkeit Spektral Empfindlichkeitskenndaten Wie aus nachfolgender Abbildung ersichtlich entspricht die Spektral Empfindlichkeits kurve in etwa den C l E Kenndaten f r Leuchtst rke C LE Internat
11. directly Locations Lux Office Conference Reception room 200 750 Clerical work 700 1500 Typing drafting 1000 2000 Factory Packing work Entrance passage 150 300 Visual work at production line 300 750 Inspection work 750 1500 Electronic parts assembly line 1500 3000 Hotel Public room Cloakroom 100 200 Reception Cashier 200 1000 Store Indoor stairs Corridors 150 200 Show window Packing table 750 1500 Forefront of show window 1500 3000 Hospital Sickroom Warehouse 100 200 Medical examination room 300 750 Operating room Emergency treatment 750 1500 School Auditorium Indoor Gymnasium 100 300 Class room 200 750 Laboratory Library Drafting room 500 1500 28 10 Spectral Sensitivity Spectral sensitivity characteristics As in the following figure can be seen the spectral sensitivity curve is about corresponding to the CIE specifications for luminosity CIE International Commission on Illumination Relative spectral sensitivity according to JIS C1609 1993 standard Typ Ta 100 Typ Ta 25 C 90 80 70 60 50 40 30 tee ums RELATIVE SENSITIVITY 300 400 500 600 700 800 900 WAVELENGTH nm Peak sensitivity 550nm Corrected Daylight LED Spectrum GJ Relativ WAVELENGTH A nm 29 11 Maintenance Battery replacement should only be done if power is off
12. e the protective cap from the photosensor 2 Switch on the unit via the ON OFF switch 7 3 Keep pressing the LX FC CD button 4 for about 2 seconds to switch to Candela CD 4 A flashing unit appears m or ft for selecting the distance of the sensor to the light source Change this value as required by the arrow keys and confirm with the LX FC CD button 4 5 Place photo sensor as vertical as possible under the measured light source or on the surface to be measured 6 Enter the distance of the sensor to the light source using the arrow keys and confirm with the LX FC CD button 4 7 Read Candela measured value in the LCD display Dg 8 After completion of the measurement put back protective cap on the sensor and switch off the unit 7 6 3 Data hold For a better reading of the measured values on hard to reach places it may be useful to freeze the current measured value in the display 1 Perform the measurement as described in the previous chapters 2 Is the desired value shown in the display press the HOLD button 9 to freeze the measured value in display 3 The Hold symbol appears in the display 4 Read the frozen measured value or save this value as described in the corresponding chapter 5 Exit the mode by pressing the HOLD button 9 6 4 MIN MAX or AVG function To activate the minimum value measurement MIN maximum value measurement MAX or the average value measur
13. ement AVG proceed as follows 1 Perform a lux or footcandles measurement as described in the previous chapters 2 Press the A button 5 for the maximum value MAX so only hold the highest measured value is kept in display 3 Press the A button 5 again to hold the continuously calculated average AVG in the display 4 Press the A button 5 again for the minimum value MIN so always hold the least measured value in the display 24 5 Press and hold the A button 5 to exit the MIN MAX AVG mode Note During the MIN MAX and AVG function the data hold HOLD is deactivated and vice versa 6 5 zeroing For self calibration the PeakTech 5086 can perform an automatic zero calibration 1 Turn on the device 7 but do not remove the cap from the sensor 2 Press the ZERO button 6 and Adj is displayed while the measured value is set to zero 3 If the zero setting does not work because the cap is not properly seated on the sensor or the ambient brightness is too great CAP appears in the display 4 If CAP is shown in the display place the cap correctly on the sensor or move to a darker environment and try again 5 If the zeroing performed correctly the unit will change to the display of Adj and back to normal measurement function 7 Internal Memory 7 1 Saving measurment values The PeakTech 5086 has an internal memory of 99 readings in Lux or Fc but not for Candela This memor
14. fernhalten Vor Aufnahme des Messbetriebes sollte das Ger t auf die Umgebungstemperatur stabilisiert sein wichtig beim Transport von kalten in warme R ume und umgekehrt Ersetzen Sie die Batterie sobald das Batteriesymbol BAT leuchtet Mangelnde Batteriespannung kann unpr zise Messergebnisse hervorrufen Sollten Sie das Ger t f r einen l ngeren Zeitraum nicht benutzen entnehmen Sie die Batterie aus dem Batteriefach S ubern Sie das Geh use regelm ig mit einem feuchten Stofftuch und einem milden Reinigungsmittel Benutzen Sie keine tzenden Scheuermittel Vermeiden Sie jegliche N he zu explosiven und entflammbaren Stoffen ffnen des Ger tes und Wartungs und Reparaturarbeiten d rfen nur von qualifizierten Service Technikern durchgef hrt werden keine technischen Ver nderungen am Ger t vornehmen Messger te geh ren nicht in Kinderh nde Reinigung des Ger tes Ger t nur mit einem feuchten fusselfreien Tuch reinigen Nur handels bliche Sp lmittel verwenden Beim Reinigen unbedingt darauf achten dass keine Fl ssigkeit in das Innere des Ger tes gelangt Dies k nnte zu einem Kurzschluss und zur Zerst rung des Ger tes f hren 2 Technische Merkmale Mehrzeilen LCD Anzeige mit Batteriezustandsanzeige Messung der Beleuchtungsst rke in Lux oder Footcandle Messung der Lichtst rke in Candela 10 Lichtquellenfaktoren frei einstellbar Geeignet f r verschiedene Leuchtmittelarten Aktualisierungsrate
15. g European Community Directives 2004 108 EC Electromagnetic Compatibility as amended by 2004 22 EC CE Marking The following safety precautions must be observed before operation Damages resulting from failure to observe these safety precautions are exempt from any legal claims whatever Check test leads and probes for faulty insulation or bare wires before connection to the equipment Comply with the warning labels and other info on the equipment Do not subject the equipment to direct sunlight or extreme temperatures humidity or dampness Do not subject the equipment to shocks or strong vibrations Do not operate the equipment near strong magnetic fields motors transformers etc Keep hot soldering irons or guns away from the equipment Allow the equipment to stabilize at room temperature before taking up measurement important for exact measurements Replace the battery as soon as the battery indicator BAT appears With a low battery the meter might produce false reading that can lead to electric shock and personal injury Fetch out the battery when the meter will not be used for long period Periodically wipe the cabinet with a damp cloth and mid detergent Do not use abrasives or solvents Do not operate the meter before the cabinet has been closed and screwed safely as terminal can carry voltage Do not store the meter in a place of explosive inflammable substances Do not modify the meter in any way Ope
16. h verboten an einer kommunalen Sammelstelle oder geben Sie sie im Handel vor Ort kostenlos ab Von uns erhaltene Batterien k nnen Sie nach Gebrauch bei uns unter der auf der letzten Seite angegeben Adresse unentgeltlich zur ckgeben oder ausreichend frankiert per Post an uns zur cksenden Batterien die Schadstoffe enthalten sind mit dem Symbol einer durchgekreuzten M lltonne gekennzeichnet hnlich dem Symbol in der Abbildung links Unter dem M lltonnensymbol befindet sich die chemische Bezeichnung des Schadstoffes z B CD f r Cadmium Pb steht f r Blei und Hg f r Quecksilber Weitere Hinweise zur Batterieverordnung finden Sie beim Bundesministerium f r Umwelt Naturschutz und Reaktorsicherheit 16 Alle Rechte auch die der bersetzung des Nachdruckes und der Vervielf ltigung oder Teilen daraus vorbehalten Reproduktionen jeder Art Fotokopie Mikrofilm oder ein anderes Verfahren nur mit schriftlicher Genehmigung des Herausgebers gestattet Letzter Stand bei Drucklegung Technische nderungen des Ger tes welche dem Fortschritt dienen vorbehalten Hiermit best tigen wir dass alle Ger te die in unseren Unterlagen genannten Spezifikationen erf llen und werkseitig kalibriert geliefert werden Eine Wiederholung der Kalibrierung nach Ablauf von einem Jahr wird empfohlen PeakTech 07 2015 Ehr 17 1 Safety precautions This product complies with the requirements of the followin
17. ige ablesen 8 Nach Abschluss der Messung Schutzkappe wieder auf dem Sensor platzieren und Ger t ausschalten 7 6 3 Messwerthaltefunktion Zum besseren Ablesen der Messwerte an schwer erreichbaren Stellen kann es sinnvoll sein den aktuellen Messwert in der Anzeige einzufrieren 1 F hren Sie die Messung aus wie in den vorausgehenden Abschnitten beschrieben N Ist der gew nschte Messwert erreicht Hold Taste 9 dr cken um Messwert in der Anzeige einzufrieren oo In der Anzeige erscheint das Hold Symbol gt Lesen Sie den eingefrorenen Messwert ab oder speichern Sie diesen Wert wie im dazugeh renden Abschnitt beschrieben a Erneut Hold taste 9 dr cken um den Modus wieder zu verlassen 6 4 MIN MAX oder AVG Funktion Zum aktivieren der Minimalwertmessung MIN Maximalwert messung MAX oder der Durchschnittswertmessung AVG gehen Sie wie folgt for 1 F hren Sie eine Lux oder Footcandle Messung aus wie in den vorausgehenden Abschnitten beschrieben 2 Dr cken Sie die A Taste 5 um den Maximalwert MAX also immer nur den h chsten gemessenen Wert in der Anzeige festzuhalten Te 4 Dr cken Sie die A Taste 5 nochmals um den Durchschnittswert AVG also den fortlaufend berechnteten Mittelwert in der Anzeige festzuhalten 5 Dr cken Sie die 4 Taste 5 nochmals um den Minimalwert MIN also immer nur den geringsten gemessenen Wert in der A
18. ional Commission on Illumination Relative Spektralempfindlichkeit nach JIS C1609 1993 Standard Typ Ta 25 C 100 SENSOR 90 RELATIVE SENSITIVITY 300 400 500 600 700 800 900 WAVELENGTH nm Spitzenempfindlichkeit 550nm Korrigiertes Tageslicht LED Spektrum a u amp 14 11 Wartung Vor dem Austauschen der Batterie Ger t ausschalten 11 1 Batterie austauschen Bei Aufleuchten des BAT Symbols muss die Batterie gewechselt werden 1 ffnen Sie das Batteriefach an der R ckseite 2 Entfernen die alten Batterien und setzen neue des gleichen Typs ein 3 Schlie en Sie das Batteriefach und befestigen die Schraube Verbrauchte Batterien sind Sonderm ll und m ssen in die daf r vorgesehenen Sammelbeh lter gegeben werden Nehmen Sie das Ger t nie in Betrieb wenn es nicht v llig geschlossen ist 15 11 2 Vorgeschriebene Hinweise zur Batterieverordnung Im Lieferumfang vieler Ger te befinden sich Batterien die z B zum Betrieb von Fernbedienungen dienen Auch in den Ger ten selbst k nnen Batterien oder Akkus fest eingebaut sein Im Zusammenhang mit dem Vertrieb dieser Batterien oder Akkus sind wir als Importeur gem Batterieverordnung verpflichtet unsere Kunden auf folgendes hinzuweisen Bitte entsorgen Sie Altbatterien wie vom Gesetzgeber vorgeschrieben die Entsorgung im Hausm ll ist laut Batterieverordnung ausdr cklic
19. lue by holding the HOLD LS key 9 for about 2 seconds 6 The device now displays the correction factor L1 to L9 which you edited 8 4 Table of Color Correction Factors Lightsource Factor CIE Standar Light Source A 1 000 LED Daylight White 0 990 LED Red 0 516 LED Amber 0 815 LED Green 1 216 LED Blue 1 475 LED Purple 1 148 Neon White 0 870 Neon Blue 1 286 Neon Green 1 167 Neon Pink 0 760 Neon Purple 0 804 Neon Red 0 671 Neon Amber 0 840 8 5 Color Correction Factor If the measured light source differs from the 2856K Planckian source the PeakTech 5086 is calibrated too an error occurs due to the spectral mismatch of the photometers This error is corrected by a color correction factor CCF as follows Usa SA dA fsa V A dA CCF S A I rer EEE A SACA V A dA JO SA dA 27 9 Recommended lighting levels 9 1 Introduction To ensure a safe working environment and to minimize eyestrain work surfaces such as office tables countertops or workrooms should generally have a good illumination but at the same time are not blinding For this there are recommendations which can be found in the following table In addition there are a variety of rules for different industries or trade associations which hold different values for precisely specified activities For further information you may contact your safety inspector or the rule making institutions
20. ning the equipment and service and repair work must only be performed by qualified service personnel Measuring instruments don t belong to children hands 18 Cleaning the cabinet Clean only with a damp soft cloth and a commercially available mild householder cleanser Ensure that no water gets inside the equipment to prevent possible shorts and damage to the equipment N Features Multi line LCD display with low battery indication Measurement of illuminance in lux or footcandles Measurement of luminous intensity in candelas 10 adjustable light source factors Suitable for different types of lighting Refresh rate 2 5 times per second Cosine Angular corrected Measurement Class A JIS C 1609 1993 CNS 5119 Data hold MIN MAX and AVG measurement Automatic range selection and zeroing HF F HF FF 19 3 Specifications Display Overrange Low battery indication Measurement rate Measuring Range Accuracy Angle deviation from Cosine characteristics Photo detector Storage temperature Power Photo Detector Dimensions Dimensions Weight LC Display 4 Counts lt 10000 Lux 5 Counts gt 10000 Lux 6 Counts gt 100000 Lux OL The BAT symbol is displayed when the battery voltage drops below the operating level 2 5 times per second nominal 40 400 4000 40000 400000 Lux 40 400 4000 40000 fc 3 calibrated to Standard Incandescent 2856k lamp 6
21. nzeige festzuhalten 6 Halten Sie die 4 Taste 5 gedr ckt um den MIN MAX AVG Modus wieder zu verlassen Hinweis W hrend der MIN MAX und AVG Funktion ist die Messwerthaltefunktion HOLD deaktiviert und umgekehrt 6 5 Nullstellung Zur Selbstkalibrierung kann das PeakTech 5086 einen automatischen Nullabgleich durchf hren 1 Schalten Sie das Ger t ein 7 entfernen Sie aber nicht die Abdeckkappe vom Sensor N Dr cken Sie die ZERO Taste 6 und es erscheint Adj in der Anzeige w hrend der Messwert auf null gesetzt wird oo _ Wenn die Nullstellung nicht funktioniert da die Schutzkappe nicht korrekt auf dem Sensor sitzt oder die Umgebungshelligkeit zu gro ist erscheint CAP in der Anzeige gt Wird CAP in der Anzeige dargestellt setzen Sie die Schutzkappe korrekt auf den Sensor oder wechseln Sie in eine dunklere Umgebung und wiederholen den Vorgang a Ist die Nullstellung korrekt abgelaufen wechselt das Ger t nach Anzeige von Adj automatisch wieder auf die normale Messfunktion 8 7 Interner Messwertspeicher 7 1 Speichern von Messwerten Das PeakTech 5086 verf gt ber einen internen Speicher f r 99 Messwerte in Lux oder Fc nicht aber f r Candela Dieser Speicher ist nicht fl chtig und h lt die Messwerte auch nach dem Ausschalten des Ger tes 1 F hren Sie eine Messung von Lux oder Fc Werten aus wie in den vorausgehenden Abschnitten beschrieben
22. y You can obtain further information about the Battery Regulations from the Bundesministerium f r Umwelt Naturschutz und Reaktorsicherheit Federal Ministry of Environment Nature Conservation and Reactor Safety 31 All rights also for translation reprinting and copy of this manual or parts are reserved Reproductions of all kinds photocopy microfilm or other only by written permission of the publisher This manual is according the latest technical knowing Technical alterations reserved We herewith confirm that the unit is calibrated by the factory according to the specifications as per the technical specifications We recommend to calibrate the unit again after one year PeakTech 07 2015 Ehr PeakTech Pr f und Messtechnik GmbH Kornkamp 32 DE 22926 Ahrensburg Germany T 49 0 4102 42343 44 i 49 0 4102 434 16 E info peaktech de www peaktech de
23. y is not volatile and holds the measured values even when the device is powered off 1 Perform a measurement of Lux or Fc values as described in the previous chapters 25 2 If you want to store the desired measurement value press the MEM READ button 3 and the M symbol for Memory with the storage number is shown on the left top of the display The storage of the values is done continuously from 01 to 99 7 2 Recall of measurement values Measured values are stored as Lux or Fc value with the respective measurement unit If you want to display a previously stored measured value proceed as follows 1 2 4 Turn on the meter Press and hold the MEM READ for about 2 seconds and R symbol for Read will appear in the upper left corner of the display with the storage number and the stored measurement value which is shown in the main display Switch between the stored values if necessary with the V A arrow keys To exit this function press and hold the MEM READ button for about 2 seconds 7 3 Delete measurement memory Only the complete data memory can be erased If you want to delete the complete memory proceed as follows Turn off the meter Press and hold the MEM READ button 3 and turn the meter on again 7 It appears CLA in the display and the internal memory is erased completely The device switches off again 25 8 Lightsources and correction factors 8 1 Light Sources