1. OLA LN o jose elo OlJOSec IO end leo e 1uon euy Jv Jv yn WY elCO Adresse Service Hotline ELCO Austria GmbH Aredstr 16 18 0810 400010 2544 Leobersdorf ELCO Belgium nv sa Z 1 Researchpark 60 02 4631902 1731 Zellik ELCOTHERM AG Sarganserstrasse 100 0848 808 808 7324 Vilters ELCO GmbH Dreieichstr 10 0180 3526180 64546 M rfelden Walldorf ELCO France 18 rue des Buchillons 0450877624 74106 Annemasse ELCO Italia S p A E EB GE 31023 Resana TV 800 087887 ELCO Rendamax B V Amsterdamsestraatweg 27 035 6957350 1410 AB Naarden Fabrique en EU Made in EU Hergestellt in der EU Document non contractuel Non contractual document Angaben ohne Gew hr 56 05 2007 Art Nr 13 022 835A
2. T Tera OOOO Neuro gt re i Le Voorsetto 9 del programmatore 43 Morsetto 5 del programmatore valvola Vorsetto B5 sulla presa Wiel 4P e morsetto 4 de d Viorsetto 6 del programmatore riscaldamento erra 45 Morsetto 4 del programmatore contatto del riscaldamento Neutro 46 Terra del programmatore e morsetto B4 sulla Neutro presa Wiel 7P contatore 1 stadio Vlorsetto B5 sulla presa Wiel 4P e morsetto 4 de 48 servomotore SM contatore 2 stadio 25 Fase 5 Morsetto T7 sulla presa Wiel AP Tera _ 5 Morseto9delprgrammatre 28 Neutro RE Fase 29 Neuro 5 Tea j 30 Morsetto3delprogrammatore 3 56 Neuro O O 38 05 2007 Art Nr 13 022 835A in presenza di un ponticello tra il 4 e il 6 oppure se il 16 Morsetto 2 del programmatore 42 Neutro Vlorsetto 26 Fase 51 MVorseto T2 sulla presa Wiel 7P 35 SI Installazione Installazione del bruciatore Condizione di montaggio del bruciatore Installazione del bruciatore sulla caldaia tipo STRATON Se viene fornita una caldaia del tipo STRATON il bruciatore gi montato In questo caso regolare la profondit di inserimento a 55 mm in base alla scala del tubo di fiamma 6 Se il bruciatore viene montato su altre caldaie eseguire l installazione in conformit con la descrizione seguente Minstallazione del bruciatore La flangia del bru
3. O J OO ON O 05 2007 Art Nr 13 022 835A Einbau e Anschlussflansch 3 mit Schrauben 4 am Kessel befestigen Rohrhalter 2 am Brennerrohr montieren und mit Schraube 1 befestigen Schraube 1 mit einem Drehmoment von max 6Nm anziehen Brenner leicht drehen in den Flansch einf hren und mit Schraube 5 befestigen Ausbau e Schraube 5 l sen e Brenner aus dem Bajonettverschlu drehen und aus dem Flansch ziehen Abgasanlage Um evtl ung nstige Schallemissionen zu vermeiden sollte bei der rauchgas seitigen Anbindung des Kessels auf DE rechtwinklige Anschlussst cke verzich tet werden Die Rezirkulations ffnung muss f r die ungehinderte Rauchgasr ck f hrung v llig frei und gut zug nglich im Feuerraum liegen Keinesfalls darf sie durch Isolationsmaterial verdeckt sein Montage Elektroanschluss Olanschluss Die Elektroinstallation und Anschlussarbeiten werden aus schlieBlich vom Elektrofachmann ausgef hrt Die geltenden Vorschrif ten und Richtlinien sind dabei zu beachten Elektrischer Anschluss Uberpr fen ob Netzspannung der angegebenen Betriebsspannung von 230 V 50 Hz entspricht Brennerabsicherung 10A Elektrische Steckverbindung Der Brenner muss mit einer den geltenden Normen entsprechen den omnipolaren Abschaltvorrich tung vom Netz getrennt werden Olanschluss Die mitgelieferten Olschl uche sind bereits an der Olbrennerpumpe ange schloss
4. Beachten Max Zulaufdruck an der Pumpe 2bar e Max Ansaugvakuum an der Pumpe lt 0 4bar Vor Inbetriebnahme l mit Handpumpe ansaugen und Dichtheit der Olleitungen berpr fen Montage Gew sserschutzkabel Option Das Gew sserschutzventil wird ber ein separat gef hrtes Kabel angeschlossen und ebenfalls durch die Bride unten auf ger Ger teplatte gef hrt und gesichert e Anschlusskabel Brennermotor 3 demontieren Zwischenstecker 4 am Brennermotor einstecken Anschlusskabel von Brennermotor in Buchse 5 einstecken Anschluss Gew sser Brandschutz ventil Gegenstecker 6 am Gew sser schutz bzw Brandschutzventil mon tieren Anlage auf Funktion pr fen Inbetriebnahme Kontrollen vor der Inbetriebnahme Einstelldaten Kontrolle der Mischeinrichtung Kontrollen vor der Inbetriebnahme Vor der Erstinbetriebnahme sind folgende Punkte zu berpr fen e Korrekte Montage des Brenners gem vorliegender Anleitung Korrekte Voreinstellung des Brenners gem Angaben Einstelltabelle Einstellung der Mischeinrichtung richtige D se muss eingesetzt sein W rmeerzeuger muss betriebsbereit montiert sein die Betriebsvorschriften des W rmeerzeugers sind zu beachten Grundeinstellwerte EL Hezir Brenner Luftd se Mese kulations Danfoss gt ffnung VBL 01 18 DUO VBL 01 22 VBL 01 26 Alle elektrischen Anschl sse m ssen korrekt ausgef hrt sein W rmeerzeuger und Heizsystem si
5. Trasformatore di accensione Scala di regolazione apertura di ricircolazione Servomotore Vite di regolazione apertura di ricircolazione Viti di fissaggio piastra dell apparecchio Angoli di aggancio Alloggiamento Presa di collegamento a 7 poli nascosta Bocchettone di aspirazione aria Portatubo con flangia di collegamento e base isolante Boccaglio del bruciatore Tubo di fiamma confezione Pulsante di sblocco Pompa gasolio Tubi flessibili gasolio HO X lt lt E ea St LIES No 071N2301 7 ES O NO Co p TEE 1 Il SWN 34 05 2007 Art Nr 13 022 835A Funzionamento Modalit di riscaldamento Modalit operativa Modalit di sicurezza Modalit di riscaldamento In presenza di un fabbisogno di calore da parte dell impianto si accende innanzi tutto il riscaldamento dell asta dell ugello Al raggiungimento della temperatura di preriscaldamento del gasolio un termostato nel riscaldamento dell asta dell ugello abilita l esecuzione del programma Il tempo di riscaldamento con avviamento a freddo di 2 minuti Avviamento del bruciatore motore del ventilatore si avvia e l accensione si inserisce Preventilazione con serranda aria aperta la serranda aria chiusa solamente a bruciatore spento L elettrovalvola 6 si apre regolazione della pressione tramite regolatore di carico parziale 5 Formazione della fiamma L accensione si spegne S
6. eure eJnsniuo Ip re ute noje nue um OUJOJOHUE ENARA ee ded ewone oAmIsOdsIq Jopnys Aem 9uO jeden adde ybe yosyonY GLL GIE 13114 GIE 13114 ON 131114 901 e onbuey Duipie l d os IIIqissej ign asoH qiX 4 uone uos GOL uonrss id euoissoJd uoisseJd enn Jeejabaiynig ae Jorejndes eanssald SE Jolfoivonmug voL aile op eyjydwen d y n eue epueuas deu Any Jep 19 OA ddejyyn SOL equiog dwod edwod dung eduiog eduing ZOL JOPe NUSA JOJe nuon 9J0 e I u9A JOMOIH In e IlUu A Joye nuen LOL JOJOWOAJSS 10joulOAJOS 9J0 ouloOAJOS 10joulOAJOS IN8JOWOAI9S qaujuejja1s OLA oejosef ep eNA enueAjeeuBeuiailo oijosef ejonjer anen I0 9n Jen euuen JAUSAIO CAILA Opipueoue JOYeWJOJSUeN OUOISU999E P JOWJOJSUeN oDeuun e p ojeunpunz LL ap JOpELUJOJSULI S6UIHE1SIUO SIOEWIOISEIL uoniuf Jn9 eulOJSUP4 Jopewenb jep J010 A 1010JN 9Jo jeionJq ep 91010 10jouu Jeuung eler 10jouueuuaeJg LIN np ANSION Bune u Bunzi u 1Opelu e5 1d JSULIPAUSAJOOA eJorep eosueJg Bon jneyneuoeJd ueBuejsuesng v3 eweli op 1019819 92010 J eWWeIJ ID 9J0 e 9AI 199 n 18 U9EMUSUUUE LA UOIXOU09 op 2 aseI soopsBuIpuIqigA ojueuuefojoo Ip pll9sspO e6pliye9o uono uuoo JUSWEPIOHIEN op ajjasse ueisexgn uosuy GV pepunDes 1eyoxspreuDireA gae id Hen ojluo2 ap 191109 jewolnes unJsng LV opuew ep eleg ua sBuiueipeg Ip a1ojeuue16014 jejes pue oJ1u02 8ll vol v3 LL
7. mid de Kann die St rung nach Kontrolle der zuvor genannten Punkte nicht beseitigt werden berpr fen Sie die mit den einzelnen Brennerteilen zusammen h ngenden Funktionen Nach Thermostatabschaltung startet der Brenner nicht mehr Automat meldet keine St rung Brenner startet bei Einschaltung ganz kurz schaltet ab und gibt folgendes Signal Nach Thermostatabschaltung startet der Brenner nicht mehr und gibt folgendes Signal Brenner l uft an schaltet kurz nach Ein setzung des Z ndtrafos auf St rung und zeigt folgendes Signal 16 e Die vom Feuerungsautomat abgege benen Blink Code beachten und ihre Bedeutung aus nachstehender Tabelle entnehmen Mit dem als Zubeh r erh ltlichen Ausle seger t k nnen dem Automaten weitere ausf hrliche Informationen ber Betriebs und St rvorg nge entnommen werden Sicherheitskomponenten d rfen nicht repariert sondern m ssen durch Teile mit derselben Bestellnummer ersetzt werden Ab oder Ausfall der Netzspannung Keine W rmeanforderung durch Ther mostaten St rung des Automaten Automat wurde absichtlich verriegelt Fremdlicht bei Vorbel ftungs Vorz ndzeit Keine Flamme nach Ablauf der Sicherheitszeit 05 2007 Art Nr 13 022 835A Nur Originalersatzteile verwenden Vor Wartungs und Reinigungs arbeiten Strom abschalten Beseitigung Ursache f r den Netzspannungsab oder ausfall feststellen Thermostat berpr fen A
8. tre remplac s par des pieces portant le m me num ro de r f rence Utiliser uniquement des pi ces de rechange d origine Rem des D terminer la cause de la baisse ou de la d faillance de tension Verifier le thermostat Remplacer le coffret D verrouiller le coffret Remplacer la vanne lectromagn tique Contr ler le niveau de fuel dans la citerne Le cas ch ant remplir la citerne Ouvrir les vannes Contr ler la pression de fuel et le fonctionnement de la pompe de l accouplement du filtre de la vanne lectromagn tique Nettoyer le circuit d allumage les lectrodes et leurs r glages Nettoyer les lectrodes Nettoyer ou remplacer la cellule de d tection de flamme Si n cessaire remplacer les pi ces suivantes Les lectrodes Les c bles d allumage Le transformateur Le gicleur Informazioni generali Indice Pagina Informazioni generali Indice i 32 Indicazioni importanti seins 32 Dati tecnici Campi di lavoro 33 Dimensioni Descrizione del bruciatore 34 Funzionamento Modalit di riscaldamento modalit operativa 35 Modalit di sicurezza 35 Programmatore di commando e sicurezza 36 Pompa gasolio del bruciatore 37 Collegamento di accessori
9. 37 Configurazione dei terminali 38 Attacco di collegamento 38 Installazione Installazione del bruciatore 39 Condizione di montaggio del bruciatore 39 Collegamento elettrico 40 Collegamento del gasolio 40 Messa in funzione Controlli prima della messa in funzione 41 Dati di impostazione Controllo del miscelatore 41 Regolazione dell aria 42 Regolazione della pressione della gasolio 42 Messa a punto del bruciatore 43 Assistenza Manutenzione 44 45 Eliminazione dei guasti 46 Indicazioni importanti Il bruciatore a gasolio VECTRON BLUE L 01 18 22 26 30 DUO stato studiato per la combustione del gasolio extraleggero secondo le paesi A ONORMC1109 standard e con basso tenore di zolfo BE NBN T52 716 gasolio extraleggero standard o NBN EN 590 e con basso tenore di zolfo CH SN 181160 2 gasolio extraleggero e gasolio eco e con basso tenore di zolfo DE DIN 51 603 1 standard e con basso tenore di zolfo bruciatori sono conformi per configurazione e funzionamento alla norma EN 267 Il montaggio la messa in f
10. 67 Olschlauch Flexible Oil hose Flessibile Olieslang A L1 00 m L1 00 m L1 00 m L1 00 m L1 00 m 13 007 665 MK L1 50 m L1 50 m L1 50 m L1 50 m L1 50 m 13 007 940 U gt Donner zu Fos ES Ensemble Joints Sieg Gumo E pm ek Accessoires Accessories Wessen eee Olfilter 3 8 mit Verschraubung Filtre fuel 3 8 avec raccord Fuel oil filter Filtro dell olio 3 8 Oliefilter BLUE L 01 18 22 BLUE L 01 18 22 BLUE L 01 18 22 BLUE L 01 18 22 BLUE L 01 18 22 20 25 um 20 25 um 20 25 um 20 25 um 20 25 um 13 014 134 BLUE L 01 26 30 BLUE L 01 26 30 BLUE L 01 26 30 BLUE L 01 26 30 BLUE L 01 26 30 50 75 um 50 75 um 50 75 um 2 50 75 um 50 75 um ges L O Ring zu Filterglas Joint torique bol de filtre Omg O Ring elem trasparente O Ring 13 018 478 Z Filtereinsatz Cartouche filtre Filter medium Inserto filtr Filterelement BLUE L 01 18 22 BLUE L 01 18 22 BLUE L 01 18 22 BLUE L 01 18 22 BLUE L 01 18 22 Sinterbronze 20 25 um bronze fritt 20 25 um sintered bronze 20 25 um bronzo sinterato 20 25 um sinterbrons 20 25 um 13 014 074 BLUE L 01 26 30 BLUE L 01 26 30 BLUE L 01 26 30 BLUE L 01 26 30 BLUE L 01 26 30 SIKU 50 75 um SIKU 50 75 um SIKU 50 75 um SIKU 50 75 um SIKU 50 75 u 13 018 480 VSE8 cc0 EL AN HV 2005 50 LG Pos Bezeichnung b signation Designation Denominazione greng an y D se Danfoss 60 80 S Gicleur Danfoss 60 80 S Nozzle Danfoss 60 80 S Ugello Danfoss 60 80 S Sproeie
11. Bij storingen moeten de essenti le voorwaarden voor een behoorlijke werking van de installatie worden gecontroleerd Is er stroom beschikbaar Zit er olie in de tank Staan alle afsluitkranen open Zijn alle regelings en beveiligingsapparaten zoals de ketelthermostaat de beveiliging tegen watertekort de eindschakelaar enz ingesteld DO I Als de storing na controle van bovenvermelde punten niet wordt opgelost moet u de werking van de afzonderlijke onderdelen van de brander controleren Tip Gebruik alleen originele reserve onderdelen zodat EMV problemen elektromagnetische verenigbaarheid worden vermeden Regelmatige controles Bij de regelmatige controle n keer per maand moeten de volgende punten worden nagezien controle van de werking van de manometer bij uitgeschakelde circulatiepomp De wijzer moet in de groene zone staan bij een te lage druk moet er water in het verwarmingssysteem worden bijgevuld vul en aftapkraan Stookoliepeil in de tank controleren Temperatuur van de ketel het toevoercircuit en de verbrandingsgassen controleren Naast de hierboven vermelde punten moet de gespecialiseerde vakman jaarlijks ook een controle uitvoeren van alle aansluitingen en leidingen het expansievat het veiligheidsventiel en de ontluchting Wanneer die voorhanden is moet ook de neutralisatiebox jaarlijks door de gespecialiseerde vakman worden gecontroleerd Verhelpen van stor
12. INFO PROG ECO Handmatig bedrijf schoor steenvegerbedrijf Foutmeldingen Infoniveau geactiveerd Programmering geactiveerd Verwarming voorbijgaand uitgeschakelde ECO functie actief Nummer van de bedienings regel Parameternummer Overzicht Technische gegevens Prestaties gemeten op een hoogte van 500 meter boven de zeespiegel STRATON 17 ISTRATON 21 STRATON 26 STRATON 30 26 Nominale verwarmingsprestatie die werd kW 18 22 32 ingesteld 1 Tweefasige low NO brander VECTRON blue L01 18 DUO L01 22 DUO L01 26 DUO L01 30 DUO Vollast Massastroom verbrandingsgassen kg s 0 009 0 010 0 013 0 015 Toegevoerde lucht tubelure mm 280 125 80 125 80 125 80 125 verbrandingsgassen Gasinhoud ketel LE Genormeerd rendement guam volgens EN 15034 bij 40 30 C 103 5 103 5 101 101 Nemdssworenn faes Waterweerstand DT 15K mbar Nominale weternoeveeihe m om os m 1M _ Prestaties ketel bij een hoogte van meer dan 500 m boven de zeespiegel op aanvraag Zonder minimumbegrenzing van de temperatuur in het terugvoercircuit Bij aansluiting van een AZ verbrandingsgassysteem zakken de temperaturen van de verbrandingsgassen al naar gelang van de lengte van het systeem met 5 10 C Overzicht Afmetingen STRATON Retourloop 1 Kabeldoorvoer Afvoergasaansluiting 80 125 Ontluchting 3 4 AG Vaste instelling 1 Vul en aftapkraan Condensaataftap DN40
13. Luftmenge reduzieren Nocke IV kleineren Skalenwert einstellen Stellmotor l uft automatisch nach e In Stufe 1 sollte CO Wert 12 5 nicht berschreiten Verpuffungsgefahr W hrend der Einregulierung st ndig CO CO und Ru emissionen pr fen Bei CO Bildung Verbrennungswerte optimieren CO Anteile sollten 50ppm nicht berschreiten Einstellung Stufe 2 Nocke V Mittels 4 poligem Stecker auf 2 Stufe schalten Uber Druckregler 2 Oldruck f r Stufe 2 entsprechend gew nschter Bren nerleistung einstellen Hierbei st ndig die Verbrennungswerte kontrollieren CO CO RuBtest Falls erforderlich Luftmenge anpassen ggf schritt weise vorgehen Luftmenge erh hen Nocke V auf h heren Skalenwert stellen Stellmo tor l uft automatisch nach Luftmenge reduzieren Nocke V auf kleineren Skalenwert stellen Stecker 4 polig kurzzeitig aus und wieder einstecken Luftklappe f hrt auf die neu eingestel Ite Position Achtung bei Einsatz an anderen Kesseln als STRATON minimal erfor derliche Abgastemperatur nach Angaben des Kesselherstellers und nach Anforderungen Abgaswege zur Vermeidung von Kondensation beachten Einstellung IRD Sonde e Brennerbetrieb in 1 Stufe e Poti A an Sonde zur ckdrehen bis 1 LED erlischt e Poti um 2 Skalenwerte h her drehen 05 2007 Art Nr 13 022 835A Einstellung Umschaltpunkt Magnetventil Stufe 2 Nocke lll e Brenner mehrmals von Stufe 1 auf Stufe 2 umscha
14. doorsnede van 3 x 1 0 mm te worden gebruikt Hiervoor dient de aan de achterkant van het apparaat aan gebrachte kabelschroefverbinding M20 en de op het besturingspaneel aan wezige trekontlasting 2 te worden gebruikt Voor alle landen geldt Vereisten bij het aanleggen van de netaansluitingskabel De stroomvoerende draden van de trekontlasting tot aan de klemmen moeten bij het uitschuiven uit de trekontlasting voor de aardingsdraad strak komen te staan De lengte van de draden moet hierop worden berekend Extra leidingen zoals voor de inwikkeling van het systeem die op de klemmenstrook in de ketel moeten worden aangesloten moeten door de ingebouwde VDE goedgekeurde trekontlastingen aan de ketel worden beveiligd Externe bedrading De externe bedrading zijn volgens het bijgeleverde elektrische schema aan te sluiten Zekering van het apparaat De zekering van het apparaat 230 V T 6 3 A bevindt zich op een gemakkelijk toegankelijke plaats op het bedieningspaneel Zekering van het apparaat vervangen Stroom voor het besturingspaneel uitschakelen Zekeringhouder 90 draaien en samen met de zekering van het apparaat verwijderen Zekering vervangen Zekeringinzetstuk terug plaatsen en 90 draaien Controleren of het ingezette deel vast zit Stroom uitschakelen lamp in netschakelaar moet branden Stekkerverbinding tussen brander en bedieningspaneel De brander en het bedieningspaneel
15. il grado di usura se necessario procedere alla sostituzione e Controllare l integrit dei collegamenti elettrici e dei cavi di collegamento ed eventualmente procedere alla sostituzione e Controllare il filtro della pompa ed eventualmente pulirlo Posizione di manutenzione 2 e Pulire il rotore del ventilatore e l alloggiamento e verificare l eventuale presenza di danni Pulire e controllare il miscelatore Smontare il disco turbolatore Sostituire l ugello del gasolio Controllare gli elettrodi di accensione ed eventualmente regolarli o sostituirli e Montare il miscelatore Attenersi alle quote di riferimento vedere pagina 41 utilizzando la dima di regolazione Montare il bruciatore e Avviare il bruciatore controllare i dati dei fumi di scarico ed eventualmente correggere le impostazioni del bruciatore e Eseguire il controllo del funzionamento del rivelatore di fiamma vedere pagina 43 Assistenza Manutenzione Posizionamenti 7 8 9 10 Ugello aria Viti di fissaggio dell ugello aria Elettrodo di accensione Vite di fissaggio elettrodo di accensione Filtro Flangia interna del rotore del ventilatore Piastra dell alloggiamento lato interno Pulire il filtro della pompa Estrarre il filtro 11 Pulire accuratamente o sostituire Reinserire il filtro 11 Controllare sostituire la guarnizione e Montare il filtro Pulire il filtro della tubazione del gasolio e Chiudere il r
16. peut tre ajust e via un d placement axial de la t te de combustion dans le tube du br leur Le positionnement s effectue au niveau de la vis de r glage 3 conform ment la valeur indiqu e dans le tableau des donn es de r glage Cette valeur peut tre relev e sur l chelle gradu e 4 Apr s la mise au point de la recirculation une nouvelle tentative de d marrage devrait tre r alis e apr s une pause d environ 5 minutes dans l exploitation de la machine Si le br leur ne d marre pas ou s il d marre en retard il faut r gler la recirculation sur des valeurs d chelle plus petites jusqu ce qu un d marrage fiable soit assur d marrage froid Ne pas exploiter le br leur avec une ouverture de recirculation trop restreint ou obstru L utilisation d une ouverture non conforme entrainerait une forte mont e de la temp rature au sein de la t te de combustion et risquerait d endommager le syst me Servomoteur Y10 1 Trois cames rouges r glables 2 Rep re de position des cames par rapport aux chelles 4 S Vis de serrage des cames 4 Deux chelles 0 18 5 Indicateur de position du volet d air 6 Fiche de raccordement amovible Il Aucune fonction I Excitation de la vanne magn tique 2nd palier IV Position du volet d air 1 palier V Position du volet d air 2 palier La r gulation d air c t pression s effectue via un volet d air Ce volet est actionn par le servomoteur
17. upplung Pumpe Accouplement pompe oupling pump Accopiamento pompa Koppeling pomp 13 009 985 Luftleitgeh use Bo tier de commande Control panel Registro d aria Luchtsturingseenheid 13 016 895 mpe BEP 52E L3 LES Pompe BEP 52E L3 LES Pump BEP 52E L3 LES Pompa BEP 52E L3 LES Pomp BEP 52E L3 LES 13 012 681 agnetspule NC 1 Stufe Bobine NC Magnetic coil NC Magnet spoel agntespule NO 2 Stufe Bobine NO Magnetic coil NO Magnet spoel 13 012 586 iltereinsatz Dichtung Filtre Joint Filter inlet seal Filtro Filter voor pomp dichting 13 012 580 ZS U eland Stecker 7p Prise Wieland7P Wieland plug 7P Connettore 7 D Wieiand stekker 13009670 nschlusskasten o Kabel Elec connection box abel m Stecker I Stufe C ble vanne 1 all able valve 1 st Cavo valvola 13 012 675 abel m Stecker Il Stufe able valve 2 st 13 012 676 lammenw chter IRD 1010 ell IRD 1010 13 012 678 Kabel m Stecker UVD IRD KLC C ble cellule able Detector 13 012 677 Kabel m Stecker Z ndtrafo Cable transformator Kabel m Stecker Motor_ Cable mo eur Cable motor Feuerungsautomat SH213 C3 Control unit SH 213 C3 Kabel m Stecker C ble r armement Remote reset cable Cavo riarmo Kabel uitgeruste Fernentrieg terugstellen i O n O 7 0S VSE8 cc0 EL AN UV 2006 50 Omschrijving D seneinstell Lehre Gabarit de r glage Nozzle adjust template GC Instelsjabloon voor de Md sproeiers Mischkopf k
18. EL und Oko Heiz l schwefelarm DE DIN 51603 1 Standard und schwefelarm Die Brenner entsprechen in Aufbau und Funktion der EN 267 Montage Inbetriebnahme und Wartung d rfen ausschlieBlich von autorisierten Fachkr ften ausgef hrt werden wobei die geltenden Richtlinien und Vorschrif ten zu beachten sind Die Anforderungen der 1 BlmSchV Stand sowie der LRV werden erf llt Die Emissionswerte NOx 120mg kWh werden unter Pr fbedingungen nach EN 267 unterschritten Je nach Feuer raumgeometrie Feuerraumbelastung und Feuerungssystem Dreizugkessel Umkehrflammkessel k nnen sich abweichende Emissionswerte ergeben F r die Angaben von Garantiewerten m ssen die Bedingungen f r die Messeinrichtung Toleranzen Luft feuchtigkeit und der Stickstoffgehalt im Heiz l beachtet werden Brennerbeschreibung Die Brenner VECTRON BLUE L 01 18 22 26 30 DUO sind 2 stufige vollautomatisch arbeitende Brenner in Monoblockausf hrung Sie sind zur Ausr stung aller der EN 303 entspre chenden W rmeerzeuger innerhalb ihres Leistungsbereiches geeignet Die spezielle Konstruktion des Brennkopfes mit interner Abgasrezirkulation erm glicht eine mit hohem Wirkungs grad ablaufende stickoxidarme Verbren nung F r einen sicheren umweltgerechten und energiesparenden Betrieb sind folgende Normen zu ber cksichtigen EN 226 I Anschluss von Olzerst ubungs und Gasbrennern mit Gebl se am W rme erzeuger EN 60335 2 Sicherheit el
19. Langes Lichtsignal A Ger t spannungslos machen Der Pause Automat darf nicht ge ffnet oder repariert werden SH213 C3 rn Erforderliche Eingangssignale mEmm Ausgangssignale 1 2 I PE zu m H peur I amp Temperaturregler Vorw rmer Brennermotor lventil Regelung Z ndtrafo Flammenw chter Stellmotor SM St rung Entriegelung Einschaltung des Automaten 6 Abschalten des Z ndtrafos Brennerbetrieb ta Wartezeit Vorw rmer Einschaltung des Brennermotors und Z ndtrafos Teillast ffnungszeit des SM Vorbel ftung und Stellmotor f hrt in Vollastposition 7 Brennerbetrieb Regelung zwischen Teil und Vorz ndung Zur ckschaltung des Stellmotors auf Teillast Vollast Schlie zeit des SM Einschaltung des Olventils 0 Regelabschaltung Sicherheitszeit Flammen berpr fung 10 _St rbetrieb Nachz ndzeit Mindestzeit zwischen Brennstoffventil 1 und 2 6 05 2007 Art Nr 13 022 835A Funktion Olbrennerpumpe Anschlussoptionen Olbrennerpumpe Die verwendete Olbrennerpumpe ist eine selbstansaugende Zahnradpumpe die als Zweistrangpumpe ber einen Entl ftungs filter angeschlossen werden muss In der Pumpe eingebaut sind Druckeinstellung 1 Stufe Druckeinstellung 2 Stufe Sauganschluss G 1 4 R cklaufanschluss G 1 4 Anschluss D senzuleitung Manometeranschluss Oldruck Druckmessanschluss Unterdruck Filter Magnetventil 1 Stufe 10 Magnetventil 2 Stufe Pumpenfilter reinigen Der Filter b
20. Maximalwerten nach EN 267 gemessen am Pr fflam menrohr Bei der Brennerauswahl ist der Kes selwirkungsgrad zu ber cksichtigen Berechnung der Brennerleistung QF BLUE L 01 18 DUO BLUE L 01 22 DUO 30 Qe Brennerleistung kW Qu Kesselnennleistung kW nK Kesselwirkungsgrad 96 BLUE L 01 26 DUO BLUE L 01 30 DUO 05 2007 Art Nr 13 022 835A 3 bersicht Abmessungen Brennerbeschreibung L LOTS 18 ON m i d Bohrungen in der Lm mm mamam Kesselanschlussplatte m5 8 twm ma m x9 9 100 toss s 25 35 120 bei T rdicke 70mm ie LIIEMUCIE INI bak pu PA kap LS Dages Kess Pd bone CE Der re CO m Jei Type EB M scoot Pb CF ni II bti QU rit Bri hel IG lfeuerungsautomat IRD Flammenw chter Elektromotor f r Pumpe und Luftrad Luftdrucknippel Z ndtransformator Regelskala Rezirkulations ffnung Stellmotor Einstellschraube Rezirkulations ffnung Befestigungsschrauben Ger teplatte Einh ngewinkel BFE TTE x La Geh use Ex ra 7 polige Anschlussbuchse verdeckt Mi Luftansaugstutzen Rohrhalter mit Anschlussflansch und Isolationsunterlage Brennerrohr Flammenrohr Beipack Entriegelungsknopf Olpumpe Olschl uche a L m i E 4 05 2007 Art Nr 13 022 835A Funktion Aufwarm
21. Minimum afstanden A B C D Afmeting al naar gelang schoorsteenaansluiting Plaats voor schoorsteenveger en het leegmaken van het condensaatsifon min 100 mm min 700 mm Plaats nodig voor het zwenken van de keteldeur min 1000 mm Plaats nodig voor het verwijderen van de geluidsdempende kap van de ketel Montage Vervoer Opstelling Toepassing De compacte verwarmingscentrale van STRATON is geschikt als warm tegenerator voor gesloten ver warmingsinstallaties voor water waarbij het toegevoerde water maximum 80 C warm is Stookruimte verluchting van de stookruimte De stookruimte moet volgens de geldende normen en constructieve voorschriften zijn uitgevoerd Er moet vooral de nodige aandacht worden besteed aan de verluchting en de luchtafvoer van de ruimte Levering van de verwarmings centrale De ketel wordt als n geheel met de brander en het elektronische bedieningspaneel in elkaar gezet en in een verpakking op een pallet geleverd Vervoer van de ketel De compacte verwarmingscentrale van STRATON na het verwijderen van de transportbeveiliging 1 voorzichtig aan de zijkant opheffen en daar een steekwagen onder schuiven Daarna kan de ketel zonder enig probleem van de pallet worden genomen Tussen de omkasting van de ketel en de steekwagen moet u zeker een plaat uit styropor 2 of iets dergelijks leggen zodat de omkasting van de ketel niet wordt beschadigd Voorpanelen van de ketel
22. Y10 La position du volet d air est d termin e par le r glage des cames IV V Les vis S permettent l ajustage En tournant vers la droite plus d air En tournant vers la gauche moins d air A Plage de r glage du servomoteur vous ne pouvez pas s lectionner un r glage sup rieur 170 17 unit s sur l chelle gradu e entre le 1er et le 24 palier 27 Mise en service R glage du br leur D marrage du br leur Faire d marrer le br leur en mettant en route le r gulateur de la chaudi re Pour obtenir une purge d air compl te de la canalisation de fuel pendant la phase de pr ventilation ouvrir la vis de purge d air sur le filtre de fuel Lors de cette intervention il ne faut pas passer en dessous d une d pression de 0 4 bar Lorsqu on voit apparaitre du fuel sans bulles et lorsque le filtre est entierement rempli de fuel refermer la vis de purge d air R glage allure 1 came IV e D brancher la fiche 4 p les le br leur fonctionne en allure 1 e Au moyen du r gulateur de pression 1 r gler la pression du fioul conform ment la puissance souhait e pour l allure 1 Contr ler continuellement les valeurs de combustion pendant cette manipulation taux de CO CO Si n cessaire adapter la quantit d air le cas ch ant proc der par tapes e Pour augmenter la quantit d air Placer la came IV sur une valeur d chelle plus grande e Brancher puis d brancher bri vement l
23. aria esterna Deve essere presente un utenza di prelievo termico serbatoi del combustibile devono essere riforniti Le tubazioni del combustibile devono essere montate a regola d arte sottoposte a controllo di tenuta e sfiatate Devono essere presenti dei punti a norma per la misurazione dei fumi il tratto del condotto dei gas di scarico deve essere a tenuta fino al punto di misura in modo che i risultati non siano falsati dall aria esterna Boris Alim entazione CO i elettrovalvola aria 2 stadio Im postazione in stadi di potenza In ogni caso verificare attentamente i valori di impostazione Rispettare i valori indicati per emissione di CO Potrebbero essere necessarie delle correzioni a seconda del particolare tipo di impianto Utilizzando gli ugelli Danfoss 60 S o Danfoss 80 S consigliati dal produttore devono ottenersi valori di combustione ottimali La dima di regolazione fornita a corredo del bruciatore pu essere impiegata per le seguenti funzioni Regolazione elettrodi di accensione 2 L 01 30 m Rn EERE Posizionamento elettrodi di accensione 05 2007 Art Nr 13 022 835A 41 Messa in funzione Regolazione dell aria Regolazione della pressione del gasolio m DA Pi Ze k E zx k Posizionamento Serranda aria del servomotore Vite di regolazione apertura di ricircolazione Scala di regolazione apertura di ricircolazione Tubo di aspiraz
24. coffret Effacement des statistigues du coffret de 9 13 secondes IP40 CEB A LINEA NN VALLI AR Pas d action sur le coffret plus de 13 secondes En erm LU NNNM IT Jr ame pete Flamme parasite pendant le temps de pr ventilation ou le temps de pr allumage Le coffret a t verrouill manuellement voir galement le verrouillage L gende Signal lumineux court Signal lumineux long Pause SH213 C3 cr Signaux d entr e n cessaires mmm Signaux de sortie Le coffret de commande SH 213 C3 commande et surveille les br leurs air souffl Gr ce la commande du d roulement du programme par micro processeur on aboutit des dur es extr mement stables ind pendamment des variations de la tension d alimentation lectrique ou de la temp rature ambiante Le Coffret est concu avec une protection contre la baisse de la tension lectrique Lorsque la tension d alimentation lectrique se situe en dessous de la valeur minimale demand e le coffret s arr te sans mettre de signal de d faut Une fois qu une tension normale a t r tablie le coffret red marre automatiquement Syst me d information _ SCH Le syst me d information visuel int gr dans le coffret fournit des informations sur les causes de mise en s curit Dans chaque cas la derni re cause de d faut est m moris e dans l appareil et peut galement tre restitu e apr s une d faillance de l alimentatio
25. durch K ufer oder Dritte einschlie lich Einbringen von Teilen fremder Herkunft bergabe und Bedienungsanwei sung Der Ersteller der Feuerungsanlage hat dem Betreiber der Anlage sp testens bei der bergabe eine Bedienungs und Wartungsanweisung zu bergeben Diese ist im Aufstellungsraum des W r meerzeugers gut sichtbar auszuh ngen Die Anschrift und Rufnummer der n chsten Kundendienststelle ist ein zutragen Hinweis f r den Betreiber Die Anlage sollte j hrlich mindestens einmal von einer Fachkraft berpr ft werden Um eine regelm ige Durch f hrung zu gew hrleisten empfiehlt sich der Abschluss eines Wartungsvertra ges bersicht Technische Daten Arbeitsfelder veto V B L 01 22 DUO V B L 07 26 DUO V BL0130DUO _ Saugleitungsdimension Tm E Regelverh ltnis 1 1 6 230V 50Hz Elektrische Leistungsaufnahme W 235 ca kg 10 Elektromotor 2800 min 85 110W Schutzart IP 21 Feuerungsautomat SH 213 C3 Flammenwachter IRD 1010 Z ndtransformator EBI M 2 x 7 5kV Magnetventil auf Olpumpe ldruckpumpe F rderleistung BFP21 L3 LES R 24 Itr 10 bar D senstange mit lvorw rmung FPHB LE 30 90W Schalldruckpegel nach VDIZ715 dB A Erl uterung zur Typenbezeichnung ian pa E Blaubrenner DUO 2 stufiger Brenner Leicht 01 Baugr e 18 Leistungskennziffer in KW Arbeitsfelder Das Arbeitsfeld zeigt die Brennerleis tung in Abh ngigkeit vom Feuerraum druck Es entspricht den
26. expiration du temps de s curit le coffret de commande et de s curit doit se mettre en d faut Maintenance Entretien Positionnement Ligne de gicleur Roue de ventilateur Coffret Gicleur Vis de fixation coffret D tecteur de flammes 2 Vis de serrage bride de raccordement Seul un chauffagiste sp cialiste et qualifi est habilit effectuer les travaux de maintenance de la chaudiere et du br leur Pour garantir un suivi r gulier des travaux de maintenance il convient de conseiller l exploitant de l installation de souscrire un contrat d entretien 0 01 QO ND Contr le de la temp rature des gaz de combustion e V rifier la temp rature des gaz de combustion Nettoyer la chaudi re si la temp rature des gaz de combustion d passe la valeur de mise en service de plus de 30 K Positions de maintenance du br leur Une fois les vis 5 desserr es la platine peut tre plac e dans deux positions de maintenance Position 1 Par exemple pour des travaux de maintenance sur la pompe Position 2 Par exemple pour des travaux de maintenance sur la t te de combustion Travaux de maintenance sur le br leur Position de maintenance 1 e Contr ler l tanch it et l usure des composants d acheminement du fioul Extraire le br leur de la bride de flexibles pompe tube pompe ligne raccordement er de gicleur ainsi que leurs raccords e Couper l alimentation lectriqu
27. gaz br l s En aucun cas cette ouverture ne doit tre recouvert d un mat riau isolant Montage Raccordement lectriq Raccordement du fioul dili de y mi ni a ue L installation lectrique ainsi que les raccordements doivent imp rativement tre effectu s par un technicien sp cialis Les consignes et instructions en vigueur dans ce domaine doivent tre respect es Raccordement lectrique e V rifier que la tension du secteur correspond bien la tension de fonctionnement donn e savoir 230V 50 Hz Protection par fusibles du br leur 10A Fiche de raccordement lectrique A Le br leur doit pouvoir tre isol du r seau l aide d un dispositif de sectionnement omnipolaire Raccordement du fioul Les flexibles fioul fournis la livraison sont d ores et d j raccord s la pompe fioul Pour viter les confusions le flexible d injection fait l objet d un marquage sp cial Le raccordement du fioul s effectue au moyen d un systeme de coul e avec filtre de purge Le filtre doit tre positionn de facon garantir un acheminement correct par flexible Les flexibles ne doivent pas tre tordus Le tube de fioul doit avoir un diam tre nominal DN4 En Suisse conduite polyamide DN4 DIN 16773 Alimentation en fioul Afin de garantir la s curit d exploitation du systeme il est indispensable d effectuer une installation soigneuse de l alimentation en fioul conform
28. il 9 13 secondi Cancellazione programmatore si riavvia automaticamente delle statistiche Sistema informativo della centralina II sistema di informazione visiva integrato iPad informa sulle cause di un blocco per RE malfunzionamento La causa dell ultimo guasto EA HH HIH CEB viene memorizzata ed rintracciabile al E Oltre 13 secondi Nessun effetto riavviarsi dell apparecchio anche dopo Uu sulla centralina un interruzione di corrente In caso di errore il diodo del pulsante di reset R si accende in modo permanente fino all eliminazione dell errore vale a dire quando il programmatore viene resettato Ogni 10 secondi l accensione inni del diodo si interrompe e compare un codice Codice lampeggiante Informazioni causa del guasto lampeggiante indicante la causa dell avaria ER j j Con il programma di visualizzazione acquisire dalla programmatore ulteriori ed E Tempo di preventilazione preaccensione esaurienti informazioni sulle modalit di funzionamento e sui guasti aun Nessun segnale di fiamma trascorso il tempo di sicurezza Bloccaggio e sbloccaggio Il programmatore pu essere bloccato messo in blocco e sbloccato resettato tramite il Luce estranea durante il tempo di preventilazione preaccensione pulsante di reset R a condizione che il programmatore sia sotto tensione Blocco manuale per malfunzionamento vedere anche Se il pulsante viene premuto durante il bloccaggio
29. la temp rature de pr chauffage du fioul est atteinte un thermostat du r chauffeur lance le d roulement du programme En conditions de d marrage froid le temps de pr chauffage est d environ 2 minutes D marrage du br leur Le moteur de ventilation et l allumage se mettent en route Pr ventilation avec le volet d air ouvert Ouverture de la vanne magn tique 6 r glage de la pression via le r gulateur de pression de d bit partiel 5 Formation de la flamme Le dispositif d allumage s arr te Sch ma du principe Pompe fioul deux allures R gulateur de pression du fioul grand d bit 104 Vanne magn tique grand d bit Y2 Pompe fioul 102 Exploitation du br leur r gulation d bit partiel grand d bit Le br leur fonctionne avec un gicleur de fioul et deux syst mes de pression du fioul pour le d bit partiel et le grand d bit Les syst mes de pression du fioul s ajustent au moyen de deux r gulateurs de pression ind pendants l un de l autre situ s dans la pompe En cas d appel du r gulateur de la chaudiere le br leur passe du d bit partiel au grand d bit dans un d lai de 60 secondes environ Le volet d air 14 est amen en position grand d bit par le moteur du volet d air Sur une autre position r glable au moyen d une came la vanne magn tique se ferme 3 le r gulateur de pression de d bit partiel 5 devient inop rant et le r gulateur de pression de grand d bit 2
30. re foyer borgne Les conditions de mesure de tol rance d humidit de l air et de teneur en azote du fioul domestique doivent tre respect es pour obtenir les valeurs garanties Caract ristiques du br leur Les br leurs air souffl VECTRON BLUE L 01 18 22 26 30 DUO sont des appareils monoblocs deux allures dont le fonctionnement est entierement automatique Ils conviennent pour l quipement de tous les g n rateurs de chaleur conformes la norme EN 303 dans leur plage de puissances La construction sp ciale de la t te de combustion avec une recirculation interne des gaz de rejet permet une combustion un faible taux d oxyde d azote et avec un coefficient de rendement lev Pour un fonctionnement en toute s curit respectueux de l environnement et conome en nergie il faut prendre en consid ration les normes suivantes EN 226 Raccordement des br leurs fioul et gaz air souffl au g n rateur de chaleur EN 60335 2 S curit des appareils lectriques usage domestique Lieu d installation Le br leur ne doit pas tre mis en service dans des locaux expos s des vapeurs agressives par exemple pulv risateurs pour cheveux t trachlor thyl ne t trachlorure de carbone poussi res abondantes ou humidit de l air lev e par exemple dans des buanderies Si aucun raccordement par gaine d air n est pr vu pour l alimentation en air une ouverture d air comburant
31. regelmatige controle n keer per maand moet aan de volgende punten de nodige aandacht worden besteed controle van de werking van de manometer bij uitgeschakelde circulatiepomp De wijzer moet in de groene zone staan bij een te lage druk moet er water in het verwarmingssysteem worden bijgevuld vul en aftapkraan Stookoliepeil in de tank controleren Temperatuur van de ketel het toevoercircuit en de ver brandingsgassen controleren Naast de hierboven vermelde punten moet de gespecialiseerde vakman jaarlijks ook een controle uitvoeren van alle aansluitingen en leidingen het expansievat het veiligheidsventiel en de ontluchting 22 Onderhoud leder jaar zou een servicetechnicus een onderhoud moeten uitvoeren Bij die controle moet er een rook gasmeting worden uitgevoerd moet de efficiency van het verbrandings proces worden gecontroleerd en moeten de volgende werkzaamheden worden uitgevoerd Demontage van de onderdelen van de branderkop schoonmaken van de luchtconus en de stuwplaat Vervangingen van oude oliesproeiers door nieuwe Schoonmaken van de ont stekingselektroden Schoonmaken van het pompfilter in de oliepomp Deksel van de behuizing van de brander afschroeven en de luchtaanzuigingskamer schoonmaken Demontage van de behuizings plaat en schoonmaken van de ventilator en de luchtwegen Controle van de luchtklep en automatische luchtafsluitklep A Reiniging
32. verleend Bij zuurstofdichte buizen kan er rechtstreeks een vloerverwarmings systeem worden aangesloten In principe moet er een controlevoorziening voor de temperatuur worden ingebouwd zodat de buizen en de vloerbedekking tegen oververhitting worden beschermd Doordat er in verschillende Bundesl nder afwijkende voor schriften bestaan is het aan te raden om voldoende inlichtingen in te winnen bij de plaatselijke bevoegde instanties en de Bezirks Schornsteinfeger meister v r men aan de installatie begint De toevoer voor de verbrandingslucht moet zo worden uitgevoerd dat er geen verbrandingsgassen uit de verwarmingsinstallaties die met vloeibare of vaste brandstoffen werken kunnen worden aangezogen De verbrandingslucht die naar de installatie wordt gevoerd mag geen chemische stoffen bevatten zoals fluor chloor of zwavel Deze stoffen zitten ondermeer in sprays oplos en reinigingsmiddelen Deze kunnen soms tot corrosie leiden ook in de afvoergasinstallatie V r de installatie in dienst wordt gesteld moet bij de bevoegde instanties worden nagegaan of het condensaat moet worden geneutraliseerd Als er technische veranderingen aan de regeling en de regelingstechnische onderdelen worden uitgevoerd vervalt de garantie bij schade Veiligheidsklep verwarmingscircuit en veiligheidsklep met het kenteken H inbouwen Maximum 3 bar afvoerleiding Als de afvoerleiding van de veiligheidsklep in het watera
33. warm tewisselaar 8 halen en reinigen De buizen van de warm tewisselaar van de ver brandingsgassen met een reinigingsborstel schoonmaken en daarna met helder water uitspoelen Voor de reiniging mogen uitsluitend nylonborstels worden gebruikt Ervoor zorgen dat de dichtings ringen bij het opnieuw monteren van het deksel juist gepositioneerd zijn Schoonmaken van de ketel Afvoergasvernauwing STRATON 17 21 Afvoergasvernauwing STRATON 26 30 Schoonmaken van de verbrandingskamer De vier bevestigingsschroeven 1 van het deksel van de ver brandingskamer 2 verwijderen De kom 3 van de verbrandings ruimte van de ketel verwijderen De bocht voor de verbrandings gassen 4 eruit nemen De wanden van de ver brandingsruimte grondig droog reinigen Bij de montage van de verschillende onderdelen moet men met de volgende zaken rekening houden Deonderdelen moeten juist uitgelijnd weer op hun plaats worden gemonteerd De kom van de verbrandings ruimte met de centreerschroef 5 aan de voorkant van de ver warmingsketel positioneren De markeringspijl 6 van het deksel van de verbrandingskamer tegenover de centreerschroef positioneren 19 Verhelpen van storingen Oorzaken en oplossing Het verhelpen van storingen mag alleen toevertrouwd worden aan erkende vaklui Deze zijn verantwoordelijk voor een behoorlijke uitvoering van de opdracht 20 Oorzaken en oplossing
34. wegnemen Kap van de brander 3 eerst naar voren trekken en daarna naar boven uit de bevestigingsbouten 4 heffen Omkastingsdeksel afnemen voor elektrische aansluiting Het omkastingsdeksel 5 naar boven opheffen De elektrische kabels worden via de daarvoor voorziene openingen 6 aan de achterkant van de ketel ingevoerd Opstelling van de ketel De ketel moet vlakbij de schoorsteen worden opgesteld Opstelling en uitlijning Deketel opstellen De ketel met een lichte helling naar de schoorsteen richten De ketel eventueel op rubberen blokjes laten rusten Verbrandingslucht Wanneer er een rookgasinstallatie wordt gebruikt die afhankelijk is van de lucht in de ruimte moet er kunnen worden gegarandeerd dat de ver brandingslucht ongehinderd door een luchtopening kan worden aangevoerd die niet kan worden afgesloten Per kW vermogen van de ketel moet er minstens 1 6 m lucht per uur worden aangevoerd Minimum vrije diameter voor de opening voor de verbrandings lucht 6 cm per kW vermogen van de ketel De overeenkomstige voor schriften moeten worden gerespecteerd Montage Aansluiting ketel met meetopening Bochtstuk 87 5 Buis met verbindingsmof 0 5 meter T vormig stuk met deksel 87 5 Steungeleider Steunboog 87 5 3 stuks buis met verbindingsmof 1 95 meter 1 stuk buis met verbindingsmof 1 00 meter Afstandhouder Afdekking schoorsteen schacht met bevestiging Controlestu
35. zijn via overeenkomstige stekker verbindingen met elkaar verbonden 13 Montage Olietoevoer Olietoevoer De brander is met twee flexibele olieslangen uitgerust die op een oliefiltersysteem worden aangesloten De maximum lengte en hoogte van de toevoerleidingen vindt u in de onderstaande tabel De lengten werden berekend met inachtneming van drukverliezen voor een afsluitkraan een terugslagventiel en vier bochtstukken en een gemiddelde dichtheid van 0 825 Schroefverbindingen mogen alleen met middelen worden afgedicht die tegen olie bestand zijn vb Teflonstroken Afmetingen leidingen DN 4 pens van de totale ea meter 14 Oliefilter Uitsluitend moet het tot de leverings omvang behorende oliefilter met een maaswijdte van 40 um worden gebruikt Olieleiding De olieleiding tussen olietank en brander moet in DN4 uitgevoerd zijn anders kunnen er branderstoringen ontstaan Installatie met n buis in combinatie met een npijpsfilter en terugvoerleiding Instelling Temperatuur van de verbrandingsgassen Temperatuur van de verbrandingsgassen Temperatuur van de verbrandingsgassen Temperatuur van de verbrandingsgassen STRATON 17 21 CO2 13 20 C Ruimtetemperatuur 18 Ketelvermogen kW Systeem Temp 45 35 emi Systeem Temp 60 45 ir Systeem Temp 80 60 Temperatuur van de verbrandingsgassen STRATON 26 30 CO 13 20 C Ruimtetemperatuur Ketelvermogen
36. 26 Contr le de la t te de combustion 26 R glage de l air R glage de la pression du fioul 27 R glage du br leur 28 Maintenance Entretien 29 30 Elimination des d fauts 31 Indications importantes Les br leurs air souffl VECTRON BLUE L 01 18 22 26 30 DUO permettent la combustion peu polluante de fioul domestique EL selon les pays A ONORM C1109 standard et basse teneur en soufre BE NBN T52 716 mazout extra l ger standard ou NBN EN 590 basse teneur en soufre CH SN 181160 2 mazout standard et basse teneur en soufre DE DIN 51 603 1 standard et basse teneur en soufre La construction et les fonctions des br leurs sont conformes la norme EN 267 L installation la mise en service et l entretien doivent tre r alis s exclusivement par des techniciens sp cialistes agr s et en respectant les directives et les prescriptions en vigueur Les exigences des normes BlmSchV Stand et LRV sont satisfaites En conditions de test les valeurs d mission restent inf rieures au maximum autoris NOx 120 mg kWh conform ment la norme EN 267 Des valeurs d mission divergentes peuvent tre mesur es en fonction de la g om trie du foyer de sa charge et du syst me de combustion chaudi re trois parcours chaudi
37. 5 16 17 18 19 20 22 23 24 25 0 26 27 28 w Te Elettrovalvola Il Monitoraggio fiamma Contatore ore di funzionamento Morsetto Connettore Nr Connettore Morsetto 29 30 31 0 32 0 33 0 34 0 35 0 36 6 370 38 39 0 400 41 42 Connettore Nr Accensione Morsetto 430 44 45 46 470 Servomotore 48 49 0 500 Regolatore di potenza 519 52 54 55 56 Alimentazione elettrica L1 Ventilazione permanente Viorsetto B del programmatore tramite i morsetti T7 se 1 stadio sulla presa Wiel 4P 1 del LMOISEHO m ESENZIONE EE Vlorsetto A del programmatore servomotore SM del servomotore 2 Morsetto 9 del programmatore I 32 Morsetto C del programmatore del servomotore V Viorsetto 7 del programmatore Eur SMD sulla presa Wiel F L TO SES E bo sulla presa Wiel AP 4 del servomotore SM e fase della valvola 2 sa Kee S Vlorsetto B4 sulla presa Wiel del servomotore ferma Viorsetto 18 sulla presa Wiel AF SM e fase della valvola 1 morsetto 5 del programmatore N Wi w D D D Vlorsetto 3 de Ra me o Viorsetto 4 de MONUTA DOTO v O Vlorsetto 6 de ET 3 del servomotore erra Vlorsetto B del programmatore tramite morsetti 12 Neut 140 Fase 15 Morsetto T derprogrammatore E Terra
38. Dispositif de r armement distance lle SA io Ca 22 Pompe fioul La pompe fioul utilis e est une pompe engrenages auto amorcant qui en tant que pompe bi tube doit tre raccord e un filtre de purge Dans la pompe sont incorpor s les l ments suivants 1 R glage pression allure 1 R glage pression allure 2 Raccordement aspiration Raccordement retour Raccordement tube pompe ligne de gicleur 2 3 G 1 4 4 5 6 Raccordementmanom tre pression 7 8 9 1 G 1 4 du fioul Raccordement prise de pression d pression Filtre Vanne magn tique allure 1 0 Vanne magn tique allure 2 Nettoyer le filtre de la pompe Le filtre se trouve sous le boulonnage 8 D visser le filtre pour proc der au nettoyage 05 2007 Art Nr 13 022 835A Fonctionnement Plan d affectation Socle de raccordement Fiche n Borne Fiche n Fiche n Borne Fiche n Borne 150 160 ie 170 29 30 430 44 45 46 470 R armement distance Contr le de flamme Allumage 31 0 180 32 0 19 33 0 20 6 SH 48 35 49 36 500 370 5106 38 52 39 Voyant de d faut Pr chauffage ligne gicleur Servomoteur 22 23 24 25 0 Vanne Compteur horaire R gulateur Moteur du br leur 54 55 56 26 27 28 400 41 Alimentation lectrique L1 Ventilation permanente Borne A du coffre sur la fiche Wieland 4 p les
39. Gebruiksaanwijzing uitsluitend voor erkende vakmensen LC O Mazoutketel STRATON 17 21 26 30 03 2007 Art Nr 12 077 447 Inhoudsopgave Inhoudsopgave Overzicht Montage Instelling Indienststelling Schoonmaken ketel Oplossen van storingen Notities Algemene instructies BEN Productbeschrijving Bedieningspaneel Technische gegevens Aimetngen een en Ve VOGI uisi aei LL A RA CLIE Opstelling x E poii er ones Aansluiting op de schoorstee Spoeling van de installatie Sensoren monteren Elektrische installatie Stookolietoevoer Temperatuur verbrandingsgassen Drukverlies Doorstroomweerstand Controlemaatregelen Oorzaken en oplossingen Controles en onderhoud Overzicht Instructies Definities Algemene instructies De installatie de opstelling de aansluiting op het elektriciteitsnet en de indienststelling moeten door een gespecialiseerde vakman worden uitgevoerd Hij is verantwoordelijk voor een deskundige uitvoering van de werkzaamheden De STRATON mazoutketel mag pas worden ge nstalleerd wanneer de plaatselijke bevoegde instanties daarvoor hun toestemming hebben
40. RATON ist der Brenner bereits fertig am Kessel montiert Die Eintauchtiefe ist in diesem Fall auf 55 mm gem Flam mrohrskala 6 einzustellen Bei Einbau des Brenners an anderen Kesseln ist die Montage gem nachfol gender Beschreibung durchzuf hren Montage des Brenners Der Brennerflansch 3 ist mit Langl chern ausgestattet und kann f r einen Lochkreis von 150 170mm verwendet werden Diese MaBe ent sprechen der EN 226 Durch Verschieben des Rohrhalters 2 auf dem Brennerrohr kann die Eintauch tiefe der Mischeinrichtung an die jeweilige Feuerraumgeometrie angepa t werden Die Eintauchtiefe bleibt beim Ein und Ausbau un ver ndert Durch den Rohrhalter 2 wird der Brenner am Anschlussflansch und somit am Kessel befestigt Der Feuerraum wird hierdurch dicht verschlossen Eintauchtiefe des Brenners Die Eintauchtiefe des Brenners so ein stellen da die Hinterkante 9 der Rezir kulations ffnung 10 b ndig mit der Kes selt risolierung 11 abschlieBt Kesselt r vorsichtig schlie en Auf den freien Schwenkradius des Flammen rohres 6 achten Falls erforderlich Brenner weiter zur ckziehen und Kes selt risolierung entsprechend aus schneiden Positionierung Sicherungsschraube z Rohrhalter Rohrhalter Anschlussflansch Schrauben z Flansch Sicherungsschraube z Flansch Flammenrohr Brennerrohr Bajonettverschlu Hinterkante Rezirkulations ffnung Rezirkulations ffnung Kesselt risolierung
41. UIS IVD N d6978L0 L oN HV ZIN ESIA 90 cL ZO 9IEQ 6890 WY 1OBIA ue seuuou sej uoo pepiuuojuoo ue oj EU V O9pJoA 990 U90J0 OJ EIO 9pJO8A HANO Jes eqep UOIDEIEISUI e ep ugio99joJd ET MO 9A U69Jc eune HeA gjep unJt HANDO ufiz 1u98e4x UEA aip ueuuou ep suabjon BuIWWOIS Inzy wne g nig en g nejg nelg Ng U9919A0 UI J90UW erje ejsui ep UEA Buiuueuoseg uo4e A Uum4g 9u0JJ 6 N UMOJ8 UOJJE N UD EJ8 Ng 1OBIA ui euuou op eyuu0Juoo UI eIBSN HEMZ 0I8N HOEIY ION ZIEMUOS Mg GV LS ZN 919559 onep euoizejeisui EP euoizejoJd ET S9 0 09 1n9 Y 110 09 510 09 SIN8 N0N U9UE N SWJOU ENIDE y UM duuoo snuJ T He Fo es Y uol pi e sui au JO U011931014 N pres na 1in nBiA ue seuuou xne HWIOJUOI LIN EE E n8 LA E uM eo ene Hop uonel eisur ep uonoejoJd e7 J va X X Al A ueuoeJdsiue ueuuoN uepueje6 Uap N SC L EE ES ssnw abejuy Jep zinyos Jor C LA _ m Gard z I P L 9 g j OA de yg na se E Ng M8 Jopewend JepueJg oJojeiongg Jeuang Jne nag HEX AN EN EN PEN EN EN AN AN AN AN gix 19UU314 al al al
42. a fiche 4 p les Le moteur du volet d air prend la nouvelle position adapt e au petit d bit e Pour r duire la quantit d air Placer la came IV sur une valeur d chelle plus petite le servomoteur s enclenche automatiquement e En allure 1 la valeur de CO ne devrait pas exc der 12 5 96 Risque de d flagration Pendant les op rations de r glage v rifier en permanence les missions de CO de CO et de suie En cas de formation de CO et ou de suie optimiser les valeurs de combustion Le taux de CO ne devrait pas d passer 50 ppm Indice de suie 1 R glage allure 2 came V e Passer en allure 2 l aide de la fiche 4 p les e Au moyen du r gulateur de pression 2 r gler la pression du fioul conform ment la puissance souhait e pour l allure 2 Contr ler continuellement les valeurs de combustion pendant cette manipulation taux de CO CO Si n cessaire adapter la quantit d air le cas ch ant proc der par tapes e Pour augmenter la quantit d air Placer la came V sur une valeur d chelle plus grande le servomoteur s enclenche automatiquement e Pour r duire la quantit d air Placer la came V sur une valeur d chelle plus petite e D brancher puis rebrancher bri vement la fiche 4 p les e volet d airtravaille avec la nouvelle position ajust e Attention en cas d utilisation sur une chaudi re de type autre que STRATON respecter la temperatur
43. amento di impianti con unita di aspirazione La tubazione di aspirazione va disposta fino 10 cm sopra il fondo della cisterna per i serbatoi cubici e fino a 5 cm peri serbatoi cilindrici Rispettare i seguenti valori e Pressione max di mandata in corrispondenza della pompa 2bar e Depressione max di aspirazione in corrispondenza della pompa lt 0 4bar e Prima della messa in funzione aspirare il gasolio con la pompa manuale e controllare la tenuta della tubazione del gasolio Montaggio del cavo antinquinamento acque accessorio opzionale La valvola antinquinamento acque viene collegata tramite un cavo a parte che viene fatto passare attraverso la staffa in basso sulla piastra dell apparecchio e poi bloccato e Smontare il cavo di collegamento del motore bruciatore 3 e Inserire il connettore intermedio 4 sul motore bruciatore e Inserire il cavo di collegamento del motore bruciatore nella presa 5 e Montare il connettore corrispondente della valvola antinquinamento acque antincendio 6 sulla valvola antinquinamento acque antincendio A Controllare il funzionamento dell impianto Messa in funzione Controlli prima della messa in funzione Dati di impostazione Controllo del miscelatore Controlli prima della messa in funzione Prima della messa in funzione iniziale necessario controllare quanto segue Corretta installazione del bruciatore secondo le istruzioni del presente manuale Cor
44. arecchi elettrici per uso domestico Luogo di montaggio Il bruciatore non deve essere messo in funzione in locali che presentano vapori aggressivi ad esempio lacca per capelli percloroetilene tetracloruro di carbonio elevata presenza di polvere o forte umidit ad esempio lavanderie Se il sistema di alimentazione aria non e provvisto di attacco LAS deve essere prevista un apertura di immissione aria con CH Apertura di immissione aria in cm superiore alla potenza del bruciatore in KWx6 ma almeno 150 cm DE fino a 50kW 150 cm per ogni ulteriore kW 2 0 cm Eventuali prescrizioni locali possono richiedere valori diversi 05 2007 Art Nr 13 022 835A per bruciatori a gasolio Noi fabbrica certificata con il n AQF030 F 74106 ANNEMASSE Cedex dichiara sotto la propria piena responsabilit che i prodotti VECTRON BLUE L 01 18 DUO VECTRON BLUE L 01 22 DUO VECTRON BLUE L 01 26 DUO VECTRON BLUE L 01 30 DUO sono conformi alle seguenti norme EN 50165 EN 55014 EN 60335 EN 60555 2 EN 60555 3 EN 267 Ordinanza reale belga del 08 01 2004 En conformit avec les dispositions des directives 89 392 CEE 89 336 CEE Direttiva Macchine Direttiva Compatibilit Elettromagnetica Direttiva Bassa Tensione Direttiva Hendimento 73 23 CEE 92 42 CEE questi prodotti recano la marcatura CE Annemasse 1 aprile 2007 J HAEP La garanzia e esclusa per danni derivanti dalle se
45. ation et d entretien Cette notice doit tre affich e un emplacement bien visible sur le lieu d installation du g n rateur de chaleur Il faut y indiquer l adresse et le num ro de t l phone du service client le le plus proche Avis l exploitant Au moins une fois par an l installation doit tre v rifi e par un technicien sp cialiste Pour s assurer d un suivi r gulier il est recommand de souscrire un contrat d entretien 17 Informations g n rales Caract ristiques techniques Courbes de puissance tee V B L 01 22 DUO V B L 01 26 DUO V B L 01 30 DUO_ Puissance du br leur minimax KW Nives sore selon VOS 488 amp B Explication des d signations BLUE Br leur flamme bleue Bas NOx DUO Br leur 2 allures L Fioul domestique 01 Dimension 18 R f rence de puissance en KW Courbes de puissance La courbe de puissance indique la puissance du br leur en fonction de la pression dans la chambre de combustion Elle correspond aux valeurs maximales selon EN 267 mesur es sur un tunnel normalis Lors du choix du br leur il faut tenir compte du rendement de la chaudiere Calcul de la puissance du br leur BLUE L 01 18 DUO BLUE L 01 22 DUO 1 BLUE L 01 26 DUO BLUE L 01 30 DUO Qe Puissance du br leur kW QN Puissance nominale de la chaudi re kW nK Coefficient de rendement de la ch
46. audi re 96 19 19 26 05 2007 Art Nr 13 022 835A Informations g n rales Dimensions Description du br leur br leur L 01 18 L 01 22 L 01 26 299 309 dG On am D mac mm E MM NM MN A toss s 25 35 120 ni II bti QU rit Bri hel IG ie LIIEMUCIE INI bak pu PA kap LS Dages Kess Pd bone CE Der re CO m Jei Type EB M scoot Pb CF E ea St LIES No 071N2301 7 ES ee m 05 2007 Art Nr 13 022 835A OON AT Oo 10 11 12 13 14 102 105 Percages dans la plaque frontale de la chaudiere Coffret de s curit D tecteur de flamme IRD Moteur lectrique pour pompe et turbine de ventilation Prise de pression d air Transformateur d allumage R glette gradu e ouverture de recirculation Servomoteur Vis de r glage ouverture de recirculation Vis de fixation platine Syst me d accrochage Carter Prise de raccordement 7 p les masqu e Tubulure d aspiration de l air Porte tube avec bride de raccordement et joint d isolation Tube du br leur Tube de flamme auxiliaire Bouton de d verrouillage Pompe fioul Flexibles fioul 19 Fonctionnement Pr chauffage Exploitation Securit Pr chauffage Pour que l installation produise de la chaleur il faut tout d abord mettre en marche le r chauffeur Lorsque
47. bons 1 de B fiche di servomoteur eee Borne 9 du coffret 923 7 Borne C du coffret borne 2 de la fiche du servomoteur Borne 7 du coffret Borne sur Ta fiche Wieland 7 p les borne 2 de la fiche du servomoteur pL Borne Bo sur la fiche Wieland a 4 p les borne 4 de la fiche du servomoteur et phase de la vanne 2 Borne 5 du co n ERN Borne B4 sur la fiche Wieland a p les borne 5 de la fiche du servomoteur et phase de la vanne 1 borne 5 du coffret leme 2 0 4 mE TE ee ENDE a lei zome du cottret erre Borne 4 du coffret esn il y a un pont entre 4 et 6 i lorsque le prechauffage est chaud alors bornes 4 et 6 O Neutre T5 Borne T du coffret ke Borne du coffret RE SE Neutre Borne 9 du coffret 4 Borne 5 du coffret vanne Borne B5 sur la fiche Wieland 4 p les et borne 4 de la d Borne 6 du coffret pr chauffage fiche du servomoteur erre I 49 Borne 4 du coffret contact de prechauffage 16 ron EE NE UNI REE i XI Borne 5 du coffret et borne B4 sur la fiche Wieland a d Neutre Tei p les compteur 19 allure En po Borne B5 sur la fiche Wieland 4 p les et borne 4 de la 48 Borne 8 sur la fiche Wieland a 4 p les lt 29 F o L lt fiche du servomoteur compteur 2 M allure Neutre 49 Borne T6 sur la fiche Wieland 4 p les Phas 5 Bomme 17 sura fiche Wieland 4 poes 26 Phase 5 BomeT2 sura fiche Wie
48. bruciatore Collegamento di accessori type BP BE LI LES R F x Alla multipresa sotto il programmatore del bruciatore possibile collegare diversi accessori opzionali di corredo In tal caso rompere il coperchio in plastica della relativa presa con l ausilio di un piccolo cacciavite e quindi inserire il cavo in direzione dell uscita vedere figure e per l ulteriore procedura di montaggio seguire le istruzioni allegate al set di accessori Comando di sbloccaggio a distanza lle SA io Ca Pompa gasolio del bruciatore Viene utilizzata una pompa a ingranaggi autoaspirante da collegare come pompa bitubo tramite una valvola di sfiato La pompa monta Regolazione pressione 1 stadio Regolazione pressione 2 stadio Attacco di aspirazione G 1 4 Attacco di ritorno G 1 4 Attacco di mandata ugello Attacco manometro pressione gasolio Attacco di misura della pressione depressione Filtro Elettrovalvola 1 stadio 10 Elettrovalvola 2 stadio Pulitura del filtro II filtro della pompa si trova sotto il raccordo filettato 8 Svitare il filtro per eseguire la pulitura coo N DQUIDSWN 05 2007 Art Nr 13 022 835A 37 Funzionamento Configurazione dei terminali Attacco di collegamento Morsetto Connettore Nr 10 20 3 4 R sbloccaggio a Comando di distanza Display guasti q N o Elettrovalvola Motore del bruciatore 1
49. chema di principio 1 Pompa gasolio del bruciatore a due stadi completa 2 Regolatore di pressione gasolio pieno carico 104 3 Elettrovalvola pieno carico Y2 4 Pompa di mandata del gasolio 102 Bruciatore in esercizio regolazione tra carico parziale e pieno carico Il bruciatore funziona con un ugello e due pressioni per il pieno carico e il carico parziale All interno della pompa le due pressioni vengono regolate da due specifici regolatori in modo da essere indipendenti l una dall altra Se richiesto dal regolatore della caldaia il bruciatore esegue la commutazione con un ritardo di circa 60 secondi dal carico parziale al pieno carico La serranda dell aria 14 viene portata dall apposito attuatore in posizione di pieno carico In una posizione regolabile tramite una camma la valvola elettromagnetica 3 si chiude il regolatore di pressione di carico parziale 5 si disattiva e il regolatore di pressione di pieno carico 2 assume la funzione di regolazione della pressione La serranda dell aria si riporta in posizione di pieno carico ora il funzionamento a pieno carico Regolatore di pressione gasolio carico parziale 104 Elettrovalvola con bypass per chiusura ugello carico parziale Y1 Serbatoio di dosaggio aria linearizzato 103 Asta dell ugello riscaldata E4 05 2007 Art Nr 13 022 835A Modalit di sicurezza Un blocco per malfunzionamento si verifica in presenza d
50. ciatore 3 munita di fori longitudinali e pu essere utilizzata per un diametro di 150 170mm Queste dimensioni corrispondono alla norma EN 226 opostando il portatubo 2 sul boccaglio del bruciatore possibile adattare la profondit di inserimento del miscelatore alla configurazione geometrica della camera di combustione La profondit di inserimento rimane invariata in caso di montaggio e smontaggio Tramite il portatubo 2 il bruciatore viene fissato alla flangia di collegamento e Profondit di inserimento del bruciatore Regolare la profondit di inserimento del bruciatore in modo che il bordo posteriore 9 dell apertura di ricircolazione 10 venga a trovarsi a filo dell isolamento dello sportello della caldaia 11 Chiudere accuratamente lo sportello della caldaia Prestare attenzione al raggio di apertura del tubo di fiamma 6 Se necessario ritrarre ulteriormente il bruciatore e ritagliare opportunamente l isolamento dello sportello della caldaia Posizionamento Vite di fissaggio del portatubo Portatubo Flangia di collegamento Viti della flangia Vite di fissaggio della flangia Tubo di fiamma Boccaglio del bruciatore Attacco a baionetta Bordo posteriore dell apertura di ricircolazione 10 Apertura di ricircolazione 11 Isolamento sportello caldaia O O O1 P QO ND ch 05 2007 Art Nr 13 022 835A pertanto alla caldaia In tal modo la camera di combustione viene chiusa a tenuta Montaggi
51. cte du br leur de pression le dispositif d assurance combustible doivent tre correctement conform ment aux indications du tableau contre le manque d eau et toute autre mont es bien tanches et purg es des r glages ventuelle installation de limitation de Un point de mesure conforme aux normes Ajustage de la t te de combustion veiller s curit disponible doivent tre doit tre install pour assurer la mesure utiliser le bon gicleur correctement raccord s et en bon tat de des gaz de combustion les voies de Le g n rateur de chaleur doit tre mont de fonctionnement recirculation des gaz de combustion facon tre pr t fonctionner les Les ouvertures de recirculation des gaz de doivent tre compl tement tanches consignes relatives l exploitation du combustion ne doivent pas tre obstru s jusqu au point de mesure afin que les g n rateur de chaleur doivent tre le cas ch ant le dispositif d air r sultats de la mesure ne puissent pas tre observ es additionnel est en fonctionnement fauss s par de l air parasite V aleurs de r glage de base R glage des paliers de puissance Ouverture Distance e l Gicleur I R glage Pression Commutation A O give de ogive Puissance Br leur AN 60 S EP du Palier de x de la vanne d air recircu d air du br leur N Danfoss recyclage puissance 2 me allure lation gicleur VBL 01 18 Plage de r glage du servomoteur max 170 Vous
52. ctrique et hydraulique Schemi elettrico e idraulico Elektrische en hydraulische schema Electric and hydraulic diagrams 53 55 05 2007 Art Nr 13 022 835A bersicht Inhaltsverzeichnis J Seite bersicht Inhaltsverzeichnis 2 Wichtige Hinweise 2 Technische Daten Arbeitsfeld 3 Abmessungen Brennerbeschreibung 4 Funktion Aufw rm Betriebs Sicherheitsfunktion 5 Feuer rgsautornial Z Z innata 6 Olbrennerpumpe Anschluss Zubeh r 7 Belegungsplan Anschlusssockel 8 Montage Brennermontage Brenner Einbausituation 9 Elektro Olanschluss 10 Inbetriebnahme Kontrollen vor der Inbetriebnahme 11 Einstelldaten Kontrolle Mischeinrichtung 11 Luftregulierung Oldruckregulierung 12 Einregulierung des Brenners 13 Service Wallis lella hora 14 15 St rungsbeseitigung eenn 16 Wichtige Hinweise Die Brenner VECTRON BLUE L 01 18 22 26 30 DUO sind ausgelegt f r die schadstoffarme Verbrennung von Heiz l EL nach Landernormung A ONORMC1109 Standard und schwefelarm BE NBN T52 716 Standard und NBN EN590 schwefelarm CH SN 181160 2 Heiz l
53. de verbrandingsgassen is intern op 120 C beveiligd In de compacte verbrandingscentrale is een bij wijze van beveiliging een temperatuurbegrenzer ingebouwd Er kan ook een systeem voor de ver brandingsgassen worden gebruikt dat niet van de lucht in de stookruimte afhankelijk is Leidingen voor de verbrandings gassen Horizontale buizenstelsels moeten worden vermeden omdat die de afzetting van condensaat in de hand werken Men moet ervoor zorgen dat de verschillende componenten goed op elkaar aansluiten Voor de montage moeten bochtstukken van 45 worden gebruikt De lood rechte delen moeten met behulp van flenzen wordt vastgezet Niet afhankelijk van de lucht in de stookruimte C63x Aansluiting lucht en verbrandings gassen via afzonderlijk geteste en geleverde leidingen voor de lucht en voor de verbrandingsgassen Installatie in de kelder of op de verdieping Toevoersysteem voor de lucht en systeem voor de verbrandingsgassen via de buitenmuur Afvoerleiding voor de verbrandings gassen door ge soleerde leiding voor verbrandingsgassen of AZ AW Afvoerleiding staande spouw aan de buitenmuur De maximum toegelaten lengte wordt per gebruikt bochtstuk korter Bochtstuk 90 1 meter Bochtstuk 45 0 8 meter Diameter leiding ver Maximum brandingsgassen J lengte 80 125 AZ LAS 100 150 AZ LAS efhankelijk van de lucht in de stookruimte niet afhankelijk van de lucht in de stookruimte Cond
54. de afzonderlijke bedrijfs handleiding Sensor monteren alleen bij gebruik met menger 1 Sensor voor de temperatuur in het toevoersysteem TV Aan te brengen minstens 50 cm boven de circulatie pomp aan de verwarmings toevoerbuis van de menger 2 Sensor voor de temperatuur van de buitenlucht TA Deze sensor is niet voorzien van bedrading Aan te brengen minstens 2 meter boven de grond indien mogelijk aan de noordzijde van het gebouw Erop letten dat de meting door de sensor niet door schoorstenen vensters enz wordt beinvloed Er moet regelmatig op functie worden gecontroleerd en mag door de proceswateropslag niet afsluitbaar zijn Bij het gebruik van proceswateropslag met elektrische nachtstroom of extra zonneverwarming moet in de laadleiding tussen ketel en opslag een terugslagklep worden gemonteerd Expansievat Het expansievat moet ter plekke worden gemonteerd Voor de aansluiting is aan de achter kant een R1 schroefdraad aanwezig Vuldruk van de installatie ca 0 2 bar boven statische hoogte 0 1 bar pro m Let op Bij een verwarmde ketel mag geen Water worden bijgevuld Manier van aanbrengen de sensor zo draaien dat de doorsteek voor de kabel van het kastje uit naar beneden loopt Lengte van de leidingen geen beperking van de lengte bij het gebruik van 1 5 mm koperleidingen Vullen van de installatie Voordat de installatie mag worden gevuld moeten de teru
55. della serranda aria si porta nella nuova posizione di basso carico e Ridurre la portata aria Regolare la camma IV su un valore di scala pi basso il servomotore adegua automaticamente la velocit e Nello stadio 1 il valore di CO non deve superare il 12 5 Pericolo di esplosione Durante la messa a punto controllare costantemente le emissioni di CO CO e di fuliggine In caso di formazione di CO ottimizzare i valori di combustione Il contenuto di CO non deve superare i 50 ppm Regolazione stadio 2 camma V e Passare al 2 stadio tramite il connettore a 4 poli e Tramite il regolatore di pressione 2 regolare la pressione del gasolio per lo stadio 2 in base alla potenza del bruciatore desiderata Nel fare ci controllare sempre i valori di combustione CO CO Se necessario adeguare la portata dell aria procedendo eventualmente in modo graduale e Aumentare la portata aria Regolare la camma V su un valore di scala pi elevato il servomotore adegua automaticamente la velocit e Ridurre la portata aria Portare la camma V su un valore di scala pi basso e Disinserire e reinserire per breve tempo il connettore a 4 poli a serranda dell aria si porta sulla nuova posizione impostata Attenzione In caso di impiego su caldaie diverse dalla STRATON rispettare la temperatura minima di scarico prescritta dal produttore della caldaia e i requisiti per i condotti di scarico dei fumi per evitare la
56. e minimale obligatoire des gaz de combustion indiqu e par le constructeur de la chaudi re ainsi que les voies de recirculation des gaz de combustion requises afin d viter toute condensation R glage de la sonde IRD e Br leur en fonctionnement en allure 1 e Tourner le potentiom tre A de la sonde jusqu ce que la LED 1 s teigne e Augmenter le r glage du potentiom tre de 2 graduations Contr le du fonctionnement de la sonde IRD Une v rification technique de la s curit de l quipement de surveillance des flammes doit tre r alis e lors de la toute premi re mise en service mais aussi apres des travaux de r vision ou apr s une p riode d immobilisation prolong e de l installation 05 2007 Art Nr 13 022 835A R glage point de commutation vanne magn tique allure 2 came III e Commuter plusieurs fois le br leur de l allure 1 l allure 2 R gler la came III de facon obtenir une transition souple de l allure 1 l allure 2 Tentative de d marrage avec le d tecteur de flammes teint apres expiration du temps de s curit le coffret de commande et de s curit doit se mettre en d faut D marrage avec le d tecteur de flammes allum apr s 10 secondes de pr ventilation le coffret de commande et de s curit doit se mettre en d faut D marrage normal lorsque le br leur est en fonctionnement teindre le d tecteur de flammes apr s un red marrage et
57. e les remplacer le cas ch ant Desserrer la vis de serrage 12 de la e V rifier l tat des raccordements bride de raccordement i lectriques et des c bles de Tourner le br leur pour l ter du joint connexion les remplacer le cas baionnette le soulever doucement ch ant puis l extraire de la bride de Contr ler le filtre de la pompe et le raccordement nettoyer le cas ch ant Il se peut que le tube de flamme soit chaud Position de maintenance 2 e Nettoyer et v rifier l tat de la turbine de ventilation et du coffret e Contr ler et nettoyer la t te de combustion e D monter le d flecteur e Remplacer le gicleur de fioul e Contr ler les lectrodes d amorcage les r ajuster ou les remplacer le cas ch ant Monter la t te de combustion Respecter les cotes de r glage voir page 26 en cas d utilisation du gabarit de r glage Monter le br leur e D marrer le br leur contr ler les analyses des gaz de combustion ventuellement corriger les ajustages du br leur e Proc der au contr le du fonctionnement du d tecteur de flamme voir page 28 05 2007 Art Nr 13 022 835A 29 Maintenance Entretien Positionnement 7 8 9 10 30 Gicleur d air Vis de fixation gicleur d air Electrode d amorcage Vis de fixation lectrode d amor age Filtre Bride int rieure roue de ventilateur Coffret face interne Nettoyer le filtre de la pompe e O
58. e IV V Per la regolazione servirsi delle viti S Verso destra pi aria verso sinistra meno aria Campo di regolazione dell attuatore Non ammesso impostare oltre 170 17 unit sulla scala tra il 1 e il 2 stadio lt z 9 01 V ND Messa in funzione Messa a punto del bruciatore Avviamento del bruciatore Prima di avviare il bruciatore aspirare il gasolio con la pompa manuale fino a riempire completamente il filtro Quindi avviare il bruciatore azionando il regolatore della caldaia Durante la fase di preventilazione per ottenere lo sfiato completo della tubazione del gasolio aprire il tappo di sfiato che si trova sul filtro del gasolio In questa operazione la depressione non deve scendere oltre 0 4 bar Quando il gasolio convogliato e esente da bollicine e il filtro completamente riempito di gasolio chiudere il tappo di sfiato Regolazione stadio 1 camma IV e Staccando il connettore a 4 poli il bruciatore si porta sul 1 stadio e Tramite il regolatore di pressione 1 regolare la pressione del gasolio per lo stadio 1 in base alla potenza del bruciatore desiderata Nel fare ci controllare sempre i valori di combustione CO CO Se necessario adeguare la portata dell aria procedendo eventualmente in modo graduale e Aumentare la portata aria Regolare la camma IV su un valore di scala pi elevato e Inserire e disinserire per breve tempo il connettore a 4 poli Il motore
59. ech 301348 Brennerrohr Tube d adaptation Adapting tube Tubo bruciatore Branderpijp 13011318 Vorsatzrohr Embout avant Blast tube Branderbuis BLUE L 01 18 22 80 13 012 679 BLUE L 01 26 0100 13 011 319 BLUE L 01 30 0120 13 011 320 Ansaugluftstutzen Manchette d air Air admission set 13017 996 Man Luftklappenantrieb Commande manu volet air Manu control air flap Bediening manu luchtklep 13 010 509 Stellantrieb Servomoteur Servomotor Servomotore Servomotor STA 5B0 36 8 5 90 STA 5B0 36 8 5 90 STA 5B0 36 8 5 90 STA 5B0 36 8 5 90 STA 5B0 36 8 5 90 Kabel m Stecker C ble servomoteur Cable Servomotor Kabel voor de Servomotor Stellantrieb Riciclaggio aria Luchtrecyclage Ansaugluftf hrung Recyclage d air BLUE L 01 18 Recycling air 13 014 509 13 010 511 13 010 512 BLUE L 01 22 BLUE L 01 26 30 Luftklappe Feder Clapet d air ressort Air shutter spring Serranda aria molla Luchtklep veer 13 010 096 Luftdosiertrommel Feder Volet d air ressort volet Air flap Spring air flap Registro dell aria molla Luchtklep veer luchtklep 13 016 896 Luftdosiertrommel d air Kabeldurchf hrung Passe fil pr chauffeur Funnel pre heater Passacavo riscaldatore 13 011 186 Deckplaite Plaquette tableau de bord _ Front plate j Ventilatorrad Turbine 0133x42 Ventilator ondensator 4uF Condensateur 4uF ondensator 4uF Condensatore 4uF Condensator Aut 13 011 117 O
60. efindet sich unter Verschraubung 8 Zur Reinigung Filter herausschrauben cO O O1 D type BP BE LI LES R F x Am Steckersockel unterhalb des Feue rungsautomaten k nnen diverse als Zubehor erh ltliche Ausr stungs gegenst nde angeschlossen werden Hierzu e am entsprechenden Steckplatz Kunststoffabdeckung mit Hilfe eines kleinen Schraubendrehers abbre chen dann Kabel in Richtung Strangaus gang stecken siehe Bilder f r die weitere Vorgehensweise die dem Zubeh rset beiliegende Monta geanleitung beachten Fernentriegelung lle SA io Ca 05 2007 Art Nr 13 022 835A 7 Funktion Belegungsplan Anschlusssockel 1 4 Klemme Stecker Nr Klemme SteckerNr SteckerNr Klemme Stecker Nr Klemme 1 Fern 1 5 entriegelung 20 YT 160 _ 3 e Anzeige 17 St rung 4 29 43 30 44 45 46 47 Flammen berpr fung 31 19 33 20 34 48 nm 35 49 Magnetventil 36 O 50 O 22 23 ido 51 38 52 24 39 Brenner 25 motor D senstangenheizung Magnetventil Il Stellantrieb Betriebstundenz hler 40 54 41 55 42 56 26 27 28 Stromversorgung L1 Dauerl ftung Bezeichnung Bezeichnung Klemme A des Automaten 31 Klemme B des Automaten durch Klemmen T6 und T7 wenn 1 St am Wiel St 4P 1 des SM St Klemme 9 des Au
61. ektrisch volgens VDE bekabeld en vooraf ingesteld Danfos LE systeem Coating van de ketel met poederlak Sokkel van de ketel met de omkasting van de ketel verbonden inclusief vier instelbare voetjes voor de ketel Bedieningspaneel met door het weer gestuurde regeling van de verwarming Bij het bedieningspaneel worden nog de volgende componenten meegeleverd ontgrendeling van op afstand ONT OFF schakelaar Temperatuurregelaar veilig heidstemperatuurbegrenzer afvoergastemperatuurbegrenzer door het weer gestuurde elektronische regeling van de verwarming van met de volgende functievarianten Korte beschrijving De verwarmingsregeling LOGON B G2Z2 is een weersafhankelijke digi tale verwarmingsregeling voor n of twee mengverwarmingscircuits en ook drinkwaterbereiding Bovendien zijn verschillende aanvullende functies in te schakelen De verwarmingsregeling berekent met behulp van de buiten temperatuursensor de noodzakelijke insteltemperaturen voor de ketel en de verwarmingscircuits en stuurt de drink waterbereiding Met extra inschakelbare optimalisatiefuncties is een optimale energiebesparing te bereiken Systeem voor toevoer van lucht in het afvoersysteem voor de verbrandingsgassen De verbrandingslucht komt via de ringvormige opening van de verbrandingsgasinstallatie in de brander terecht Als de klant dat wil kan de ketel ook bediend worden met lucht die niet afhankelijk is van de omgevi
62. ektrischer Ger te f r den Hausgebrauch Aufstellungsort Der Brenner darf nicht in R umen mit aggressiven D mpfen z B Haarspray Perchlor thylen Tetrachlorkohlenstoff starkem Staubanfall oder hoher Luft feuchtigkeit z B Waschk chen in Betrieb genommen werden Sofern f r die Luftversorgung kein LAS Anschlu ausgef hrt wird mu eine Zuluft ffnung vorhanden sein mit DE bis 50kW 150cm f r jedes weitere kW 2 0cm CH QF kW x 6 cm mind jedoch 150cm Aus kommunalen Vorschriften k nnen sich Abweichungen ergeben 05 2007 Art Nr 13 022 835A Konformitatserklarung f r Olgebl sebrenner Wir mit AQFO30 gepr ftes Werk F 74106 ANNEMASSE Cedex erkl ren in alleiniger Verantwortung daf3 die Produkte VECTRON BLUE L 01 18 DUO VECTRON BLUE L 01 22 DUO VECTRON BLUE L 01 26 DUO VECTRON BLUE L 01 30 DUO mit folgenden Normen bereinstimmen EN 50165 EN 55014 EN 60335 EN 60555 2 EN 60555 3 EN 267 Belgischer k niglicher Erla vom 08 01 2004 Gem den Bestimmungen der Richtlinien 89 392 EWG 89 336 EWG 73 23 EWG Maschinenrichtlinie EMV Richtlinie Niederspannungs richtlinie Wirkungsgrad richtlinie 92 42 EWG werden diese Produkte CE gekenn zeichnet Annemasse den 1 April 2007 J HAEP F r Sch den die sich aus folgenden Gr nden ergeben schlie en wir die Gew hrleistung aus unsachgem e Verwendung fehlerhafte Montage bzw Instand setzung
63. en Zur Vermeidung von Verwechslungen ist der Vorlaufschlauch speziell markiert Der Olanschluss erfolgt mittels Einstrangsystem mit Ent l ftungsfilter Der Filter ist so zu plazie ren dass eine fachgerechte Schlauchf hrung gew hrleistet ist Die Schl uche d rfen nicht knicken Die Olleitung ist in Nennweite DN4 auszuf hren In der Schweiz Polyamid Olleitung DN4 DIN16773 Olversorgung Zu Gew hrleistung der Betriebs sicherheit der Anlage ist die sorgf ltige Installation der Olversorgung nach DIN 4755 sowie unter Beachtung rtlicher Vorschriften erforderlich 05 2007 Art Nr 13 022 835A k nnen Brenner und W rme erzeuger Kessel werden ber eine siebenpolige und eine vierpo lige Steckverbindung 2 miteinan der verbunden Der Durchmesser der auf diesem Stecker ange schlossenen Kabel muss unbedingt zwischen 8 3 und 11mm liegen Das Anschlusskabel wird durch die Anschlussbride gef hrt und gesichert Die Steckverbindung 1 dient zum Anschluss einer Fernentriegelung Das Kabel wird durch die Bride unten auf der Ger teplatte gef hrt und gesi chert Es ist ein Filter mit einer Maschen weite lt 25 um einzusetzen Grenzwerte f r Saugleitungsl ngen und Saugh hen gem Procal Richtlinie bzw Richtlinie zur Projektierung und Dimensionierung von Anlagen mit Saug installation einhalten Die Saugleitung wird bei kubischen Tanks bis 5cm und bei zylindrischen bis 10cm ber Tankboden gef hrt
64. en ook als het gehele product conform de bestemming ervan wordt gebruikt zulke onder delen zijn bijvoorbeeld olie injectoren oliefilters Voor slijtage en onderhoudsonderdelen is de garantie van levensduur volgens de handelsvoorwaarden van ELCO niet van kracht Maintenance parts are parts which should be replaced on a preventive basis during maintenance when reassembling disassembled parts sealing components for example For wear parts and maintenance parts ELCO s performance warranty for them over time under commercial conditions does not apply Wear parts are parts that have to be replaced several times during the product s service life even when use of the overall product is in line with its intended purpose for example oil injectors and oil filters For wear parts and maintenance parts ELCO s performance warranty for them over time under commercial conditions does not apply 05 2007 Art Nr 13 022 835A elco Elektro und Hydraulikschema Sch mas lectrique et hydraulique Schemi elettrico e idraulico Elektrische en hydraulische schema Electric and hydraulic diagrams 18 DUO 22 DUO 26 DUO 30 DUO VECTRON BLUE VECTRON BLUE VECTRON BLUE VECTRON BLUE rr rr O O O O BLUE L 01 18 DUO 13 022 833 13 022 834 13 022 771 13 022 772 D D D r m m C C C m m m C r r g w N N e ep N g g g C C C O O O 05 2007 Art Nr 13 022 835A c eDeg S860 L 01 EWS
65. ensaat De aansluiting van de afvoer van het condensaat achter de ketel moet met een helling naar de afvoer worden geleid Ook mag er in geen geval vorstgevaar zijn 11 Montage Anlagensp lung Fuhler montieren Kabeldoorvoer voor netaansluiting Aansluiting ontluchtingsklep Aansluiting buis verbrandingsgasse Aansluiting condensaat Toevoer ketel Retourleiding ketel Vul en aftapkraan Aansluiting expansievat 2m Spoeling van de installatie V r de ketel op een bestaande ver warmingsinstallatie wordt aangesloten moet deze grondig worden gespoeld Anders zal er zich vuil en slib in de ketel ophopen wat tot lawaai en plaatselijke oververhitting kan leiden De garantie vervalt voor beschadigingen aan de ketel die hieraan te wijten zijn Aansluiting buffer proceswater Wanneer de compacte verwarmings centrale van STRATON met een buffer voor proceswater wordt gecombineerd moet men erop letten dat de omvang en het vermogen overeenkomen met het ge nstalleerde ketelvermogen In verband met de aansluiting en de uitrusting van de buffers voor proces water moeten de geldende voor schriften de algemeen geldende regels van de techniek en de van toepassing zijnde richtlijnen worden gerespecteerd In ieder geval moet een overschrijding van de toegelaten bedrijfsoverdruk door middel van een constructief getest membraanveilig heidsventiel worden vermeden Pompgroep Montage en ingebruikneming haalt u uit
66. erd laagspannings en de netspannings Instelbare temperatuursensor kabels afzonderlijk worden gehouden GAD 36 NTC 10 kO Deze kabels mogen niet in een Opslagtemperatuursensor gemeenschappelijke leiding binnen QAZ 36 NTC 10 kO een kabel of een installatiebuis of Collectortemperatuursensor binnen een kabelkanaal worden Ruimteunit gelegd VDE richtlijnen Verder QAA 75 met kunnen inductiespanningen storingen Tweedraadverbinding in de goede werking en bediening van QAA 78 voor radioverbinding de installatie veroorzaken Radiozender voor buitentemperatuursensor QAC 34 Radio ontvanger voor buitentemperatuursensor QAC 34 en of ruimteunit QAA 78 Overzicht Bedieningspaneel met Verwarmingsregelaar LOGON B G222 Functies verwarmingsregeling weersafhankelijke warmteregeling voor max een glijdende en twee gemengde circuits Drinkwatersturing met vrijgave en vaste instelwaarde Extra inschakelbare tijdgestuurde circulatiepomp Drinkwater zonne energieregeling met collectorbeveiligingsfunctie en retourkoelmogelijkheden Relais en sensortest voor ingebruikneming Display verlicht voor status en functie indicaties in duidelijke test in 5 talen Automatische omschakeling tussen zomer wintertijd Van tevoren ingestelde standaardtijdprogramma s voor verwarming en drinkwaterbereiding Individueel schakelprogramma met max 84 vrije schakeltijden overeenkomstig de regel installatieconfiguratie Vakantieprogramma voor elk verwar
67. f sein nn 2 1 nee Lia a A E een ET AE atte Fe Ae ig Ee x e AT gia Peja f sai nds MT EI De a 05 2007 Art Nr 13 022 835A Positionierung D sengest nge Ventilatorrad Geh useplatte D se Befestigungsschrauben Geh useplatte Flammenw chter Klemmschraube Anschluss flansch A O O1 QO ND N Wartungspositionen Brenner Nach L sen der Schrauben 5 kann die Ger teplatte in zwei Wartungspositio nen eingeh ngt werden Position 1 Zum Beispiel f r Wartungsarbeiten an der Pumpe Position 2 Zum Beispiel f r Wartungsarbeiten an der Mischeinrichtung Wartungsarbeiten am Brenner Wartungsposition 1 e Olf hrende Komponenten Schl uche Pumpe D senzuleitung sowie deren Verbindungen auf Undichtigkeiten oder VerschleiBerscheinungen pr fen ggf austauschen Elektrische Anschl sse und Ver bindungskabel auf Besch digungen berpr fen ggf auswechseln Pumpenfilter kontrollieren und ggf s ubern Wartungsposition 2 e L fterrad und Geh use reinigen und auf Besch digungen berpr fen Mischeinrichtung pr fen und reinigen Stauscheibe demontieren Old se austauschen Z ndelektroden pr fen ggf nachjus tieren oder austauschen Mischeinrichtung montieren Einstell ma e siehe Seite 11 unter Verwendung der Einstellschablone beachten e Brenner montieren Brenner starten Abgasdaten kontrol lieren Brennereinstellungen ggf kor rigieren Funktionskontrolle Flammen
68. ffeur Mise en route du moteur du br leur et du Arr t du transformateur d allumage exploitation du br leur en d bit partiel Exploitation du br leur r gulation d bit A Gs THA AL C gt v x P Contr le de flamme Servomoteur SM D faut D verrouillage ta Temps d attente pr chauffeur tk Temps d ouverture du SM pr ventilation et pr allumage transformateur d allumage le servomoteur fonctionne en position grand d bit Retour du servomoteur sur le mode d bit partiel Mise en route de la vanne fioul Contr le de flamme partiel grand d bit tr Arr t r gulation ts Exploitation mode incident tn 05 2007 Art Nr 13 022 835A Temps de fermeture du SM Temps de s curit Temps de post allumage Temps minimal de passage entre la vanne de combustible 1 et la vanne de combustible 2 21 Fonctionnement Pompe fioul Possibilit s de raccordement type BP BE LI LES R F x Diff rents composants d quipement disponibles en accessoires peuvent tre raccord s au socle sur la partie inf rieure du coffret de commande et de s curit Pour ce faire e l emplacement d en fichage correspondant ter le cache en plastique l aide d un petit tournevis e Ensuite ins rer le c ble dans le sens de la sortie de phase voir illustrations e Pour les autres indications de proc dure consulter la notice de montage qui accompagne le jeu d accessoires
69. formazione di condensa Impostazione sonda IRD e Bruciatore in esercizio nel 1 stadio e Ruotare all indietro il potenziometro A della sonda fino ad ottenere lo spegnimento del LED 1 e Aumentare il potenziometro di 2 valori di scala Controllo del funzionamento della sonda IRD E necessario procedere a una verifica di sicurezza del monitoraggio fiamma sia dopo la messa in funzione iniziale sia dopo le revisioni o dopo un periodo di inattivit prolungato Tentativo di avviamento con rivelatore 05 2007 Art Nr 13 022 835A Regolazione del punto di commutazione Elettrovalvola stadio 2 camma lll e Commutare pi volte il bruciatore dal 1 al 2 stadio Regolare la camma III in modo da garantire un passaggio scorrevole dallo stadio 1 allo stadio 2 di fiamma oscurato trascorso il tempo di sicurezza il programmatore deve andare in blocco Avviamento con rivelatore di fiamma non oscurato dopo 10 secondi di preventilazione il programmatore deve andare in blocco Avviamento normale quando il bruciatore in funzione oscurare il rivelatore di fiamma dopo un nuovo avviamento e trascorso il tempo di sicurezza il programmatore deve andare in blocco 43 Assistenza Manutenzione Le operazioni di manutenzione che interessano la caldaia o il bruciatore devono essere eseguite esclusivamente da tecnici qualificati Per garantire la periodica esecuzione delle operazioni di manutenzione per l utente del
70. funktion Betriebsfunktion Sicherheitsfunktion Aufw rmfunktion Wird von der Anlage W rme verlangt so schaltet zuerst die D senstangenhei zung ein Bei Erreichen der Olvorw rmtemperatur gibt ein Thermostat in der D senstan genheizung den Programmablauf frei Die Aufheizzeit bei Kaltstart betr gt ca 2 Minuten Brennerstart Gebl semotor l uft an Z ndung schaltet ein Vorbel ftung mit ge ffneter Luftklappe Magnetventil 6 ffnet Druckregulie rung ber Teillastdruckregler 5 Flammenbildung Z ndung schaltet aus Prinzipschema Zweistufen Olbrennerpumpe kpl Oldruckregler Vollast 104 Magnetventil Vollast Y2 Oldruckpumpe 102 Oldruckregler Teillast 104 Brennerbetrieb Regelung zwischen Teil und Vollast Der Brenner arbeitet mit einer Old se und mit zwei Oldr cken f r Teil und Vollast Die Oldr cke werden mit zwei Druckre glern in der Pumpe unabh ngig vonei nander reguliert Bei Anforderung durch den Kesselregler schaltet der Brenner mit einer Verz gerung von ca 60 Sekunden von Teillast auf Vollast Die Luftklappe 14 wird durch den Luftklappenantrieb auf Vollastposition gefahren Bei einer durch eine Nocke einstellba ren Position schlief3t Magnetventil 3 Teillastdruckregler 5 wird unwirksam Vollastdruckregler 2 bernimmt die Druckregulierung Luftklappe f hrt weiter in Vollastposi tion Vollast ist in Betrieb Magnetventil mit Bypass f r D sen abschl
71. funzionamento normale o in fase di avviamento l apparecchio va in blocco Se si preme il Spiegazione pulsante in presenza di un guasto il Segnale luminoso breve programmatore viene sbloccato Segnale luminoso prolungato Prima di smontare o montare il Pausa programmatore togliere la corrente Il programmatore non pu essere aperto o riparato SH213 C3 cr Segnali di ingresso necessari mmm segnali di uscita H t tvi 225 CLONE _ en he sn A lt Regolatore di temperatura Preriscaldatore Motore del bruciatore Valv gasolio Regolazione Trasf di accens Rivelatore di fiamma Servomotore SM Guasto Sbloccaggio Accensione della programmatore e del Monitoraggio fiamma ta Tempo di attesa preriscaldatore preriscaldatore Disinserimento del trasformatore di accensione Tempo di apertura del servomotore SM Accensione del motore del bruciatore e del bruciatore in esercizio carico parziale preventilazione e preaccensione trasformatore di accensione Il servomotore si Bruciatore in esercizio regolazione tra carico Tempo di chiusura del servomotore SM porta in posizione di pieno carico parziale e pieno carico Tempo di sicurezza Ricommutazione del servomotore sul carico Arresto regolare Tempo di post accensione parziale Modalit di guasto Tempo minimo tra la valvola del combustibile 1 e 2 Inserimento della valvola gasolio 36 05 2007 Art Nr 13 022 835A Funzionamento Pompa gasolio del
72. fvoersysteem uitmondt moet er een stankscherm worden voorzien Definities Voor een veilig milieuvriendelijk en energiezuinig gebruik van de installatie dient u met de volgende normen rekening te houden 92 42 EWG Rendementsrichtlijnen 73 23 EWG EG Laagspanningsrichtlijn 89 336 EWG EG Richtlijn voor de elektro magnetische verdraagbaarheid EN 303 Verwarmingsketel met ventilatorbrander DIN EN 267 Olieverstuiverbrander EN 15034 Olieverbrandingswaardeketel EN 15035 Olieverbrandingswaarde ketel voor ruimteonanfhankelijk gebruik DIN 1988 leidingsinstallaties voor drinkwater op bouwterreinen technische bepalingen voor constructie en gebruik DIN 18160 schoorsteen ATV A 251 toevoer van condensaat uit verbrandingsruimten in openbare rioolinstallaties DIN 4701 regels voor het berekenen van de verwarmingsbehoeften van gebouwen EN 12828 Veiligheidstechnische uitrusting van verwarmingsinstallaties met ingestelde temperaturen tot 95 C VDE 0100 bepalingen voor het plaatsen van sterkstroominstallaties met nominale spanningen tot 1 000 V VDE 0105 bepalingen voor het plaatsen van sterkstroominstallaties met nominale spanningen tot 1 000 V EN 50165 elektrische uitrusting van verwarmingstoestellen die niet met elektriciteit werken EN 60335 1 veiligheid van elektrische apparaten voor huishoudelijk gebruik en vergelijkbare toepassingen Bij installaties in Oostenrijk gelden ook nog de volgende
73. gsgassen moeten de desbetreffende plaatselijke voor schriften worden gerespecteerd De compacte verwarmingscentrale van STRATON mag uitsluitend in combi natie met toegelaten systemen voor de verbrandingsgassen worden gebruikt Constructieve installaties voor de ver brandingsgassen moeten ongevoelig zijn voor vochtigheid corrosiebestendig en condensaatdicht Ze moeten ook bestand zijn tegen statische krachten en krachten die tijdens de werking ont staan De verbrandingsgassen moeten ongehinderd via de schoorsteen kunnen worden afgevoerd er wordt daarom beter geen schoorsteenkap gebruikt De verbinding tussen de schoorsteen en de compacte ver warmingscentrale moet met een helling worden uitgevoerd 3 zodat het condensaat dat wordt gevormd uit de buis voor de verbrandingsgassen kan terugvloeien Deze verbinding moet zo recht mogelijk worden uitgevoerd In de buis voor de verbrandingsgassen Niet afhankelijk van de lucht in de stookruimte C33x Toevoer van lucht en afvoer van ver brandingsgassen via het dak in hetzelfde drukbereik Installatie in de kelder Toevoersysteem voor de verbrandings gassen tot de schoorsteen voor de verbrandingsgassen Toevoer van lucht en afvoer van ver brandingsgassen via het dak Inbouw in schoorsteen voor de afvoer van verbrandingsgassen die niet gevoelig is voor vocht moeten inspectie openingen worden voorzien die aan de plaatselijke voor schriften voldoen De maximum temperatuur voor
74. gslagkleppen en de afsluitkranen aan de pompen worden open gezet De installatie moet langzaam via de vul en de aftapkraan worden gevuld zodat het systeem correct kan worden ontlucht De pompen moeten via de ontluchtingsschroeven worden ontlucht Nadat de installatie werd gevuld moeten de ontluchtingsschroeven van de pomp worden gesloten en moeten de terugslagkleppen in de bedrijfspositie worden geplaatst Er mogen geen chemische beschermingsmiddelen tegen corrosie gebruikt worden Montage Elektrische installatie Netaansluiting voor uitvoering CH Zwitserse stekker in de betreffende contactdoos steken Netaansluiting uitvoering D A B De elektrische installatie en de aansluiting mogen uitsluitend door een gekwalificeerde elektricien worden uitgevoerd Daarbij moeten de nationale voor schriften en bepalingen worden gerespecteerd De ketel het bedieningspaneel en de pompeen heid zijn via kabels verbonden met stekkers Ze worden aan de klemmen strook van het bedieningspaneel via een daarvoor voorzien en beveiligd stroomcircuit op het net aangesloten De verwarmingscentrale moet door aangepaste middelen van het net gescheiden kunnen worden Daarvoor kunnen schakelaars met een contactopeningsbreedte van meer dan 3 mm of leidingsbeveiligings schakelaars worden gebruikt Netspanning 230 V 50 Hz Beveiliging van de netaansluiting 10 A Als nettoevoer voor het apparaat dient een vaste kabel met een minimum
75. guenti cause utilizzo improprio installazione o riparazione eseguiti in modo errato dall acquirente o da terzi compreso l inserimento di pezzi non originali Consegna e istruzioni per l uso II produttore dell impianto di combustione deve consegnare all utente al pi tardi al momento della consegna un manuale d uso e manutenzione manuale dovr essere conservato in maniera ben visibile nel locale del generatore di calore Riportare sul manuale l indirizzo e il numero di telefono del centro di assistenza pi vicino Avvertenza per l utente L impianto deve essere controllato periodicamente da un tecnico qualificato Si consiglia la stipula di un contratto di manutenzione per garantirne l esecuzione periodica Informazioni generali Dati tecnici Campi di lavoro DURS V B L 01 18 DUO V BL 01 22 DUO V BL 01 26 DUO V BL 01 30 DUO Potenza del bruciatore min max kW 11 18 14 22 19 26 19 30 Prova di tipo secondo la norma EN 267 classe di emissione 3 e secondo LRV ordinanza svizzera contro l inquinamento atmosferico Dimensioni tubo di aspirazione mm Potenza eletirica assorbi W 85 TOW P2 SH 213 03 RD 1010 Trasformatore di accensione EBI M 2 x 7 5kV Elettrovalvola su pompa gasolio Pompa di mandata del gasolio portata BFP52 EL3 LES H 24 litri 10 bar Stanga con preriscaldamento FPHB LE 30 90W Rumorosita secondo VDI2715 dB A Legenda della sigla del tipo BLUE Bruciatore blu f
76. i un segnale di fiamma durante la preventilazione monitoraggio luce estranea quando all avviamento abilitazione combustibile dopo 10 secondi tempo di sicurezza non si formata nessuna fiamma quando durante il funzionamento la fiamma si spegne e non si riforma nonostante il tentativo di riaccenderla Il blocco per malfunzionamento viene segnalato dall accensione della relativa spia e una volta eliminata la causa pu essere sbloccato premendo il pulsante di sblocco Per ulteriori informazioni vedere la descrizione del programmatore del bruciatore Valvola a membrana per chiusura dell ugello Motore del bruciatore M1 Boccaglio del bruciatore Tubo di fiamma Attuatore elettrico della serranda dell aria Y10 35 Funzionamento Programmatore di commando e sicurezza SH 213 C3 Il programmatore di commando SH 213 C3 controlla ed esegue il SE del kink bruciatore con ventilatore Grazie al programma Premendo R per si ottiene comandato da microprocessore si er tempi estremamente stabili indipendentemente dalle oscillazioni della tensione di rete e della meno di 9 Sbloccaggio o temperatura ambiente Il programmatore del secondi bloccaggio della bruciatore e provvista di protezione a fusibile da sottotensione Quando la tensione di rete centralina inferiore al minimo richiesto ilprogrammatore si disinserisce senza emettere segnali di errore Al ripristino della tensione normale
77. iamma Low NOx DUO Bruciatore bistadio L Gasolio 01 Dimensioni 18 Coefficiente di potenza in KW Campi di lavoro Il campo di lavoro mostra la potenza del bruciatore in funzione della pressione nella camera di combustione di Corrisponde ai valori massimi in base alla norma EN 267 misurati sul tubo di fiamma di prova Nella scelta del bruciatore tenere conto del rendimento della caldaia Calcolo della potenza del bruciatore BLUE L 01 18 DUO BLUE L 01 22 DUO 0 15 2 BLUE L 01 26 DUO z BLUE L 01 30 DUO 19 o0 oe 5 20 25 30 05 2007 Art Nr 13 022 835A 33 1 0 QF Potenza del bruciatore kW Qu Potenza nominale della caldaia KW nK Rendimento della caldaia 96 Informazioni generali Dimensioni Descrizione del bruciatore SUL del F n GG OH ruciatore s in mm mm Fori nella piastra di attacco L0118 m ma mm mamam A ida a Ces 35 80 Loa 359 288 2 80 89 toss s 25 35 120 con uno spessore sportello di 70mm ie LIIEMUCIE INI bak pu PA kap LS Dages Kess Pd bone CE Der re CO m Jei Type EB M scoot Pb CF ni II bti QU rit Bri hel IG Programmatore dei comandi e sicurezza Rivelatore di fiamma IRD Motore elettrico per pompa e girante del ventilatore Nipplo di mandata aria
78. ificato nella tabella sottostante Con il display disponibile come accessorio possibile acquisire del programmatore ulteriori ed esaurienti informazioni sulle modalit di funzionamento e sui guasti componenti di sicurezza non possono essere riparati e devono essere sostituiti con parti che hanno lo stesso codice di ordinazione A Utilizzare esclusivamente ricambi originali Staccare la corrente prima di eseguire interventi di manutenzione o di pulizia Eliminazione Stabilire la causa del calo o della interruzione di tensione Controllare il termostato Dopo il disinserimento del termostato non Calo o interruzione della tensione di rete pi possibile riavviare il bruciatore I termostati non rilevano fabbisogno di calore Il programmatore non segnala nessun Sostituire il programmatore guasto Guasto del programmatore Il programmatore stata bloccata Sbloccare la centralina intenzionalmente All accensione il bruciatore si avvia per brevissimo tempo poi si spegne inviando il seguente segnale Luce estranea durante il tempo di Sostituire l elettrovalvola preventilazione preaccensione Dopo il disinserimento del termostato il bruciatore non si avvia pi ed invia il seguente segnale Controllare il livello del gasolio nel serbatoio Eventualmente rifornire il serbatoio Aprire le valvole Nessuna fiamma trascorso il tempo di sicurezza Il bruciatore si avvia e poco dopo l i
79. ingen Oorzaken en oplossing Geen ontsteking Motor van de brander start niet op Oliepomp verpompt geen olie Luid mechanisch lawaai Ongelijkmatige olieverstuiving Kortsluiting ontstekingselektroden Ontstekingselektroden staan te ver uit elkaar Ontstekingselektroden vervuild en of vochtig Isoleerlichamen gesprongen Ontstekingstransformator defect Ontstekingskabel verschroeid Motor van de brander defect lager vastgelopen Condensator defect Transmissie beschadigd Aanzuigklep niet dicht Olieleiding niet dicht Afsluitventielen gesloten Filter verstopt Filter niet dicht Oliepomp werkt niet goed Koppeling defect Oliepomp zuigt lucht aan Te hoog vacu m in de olieleiding Sproeier los Sproeier verstopt Sproeier versleten Sproeier met verkeerde sproeihoek Instellen Instellen Schoonmaken Ontstekingselektrode vervangen Vervangen 1 Kabel vervangen 2 Oorzaak opsporen en oplossen Vervangen Motor van de brander vervangen Vervangen Oliepomp vervangen Demonteren en schoonmaken of vervangen Schroefverbindingen vastzetten Openen Schoonmaken Vervangen Oliepomp vervangen Vervangen Schroefverbindingen vastzetten Filter schoonmaken ventielen helemaal open zetten Vastschroeven Vervangen Vervangen Vervangen Geen oliedoorvoer Sproeier verstopt Vervangen Vlammensensor reageert niet Viammensensor vervuild defect Schoonmaken resp vervangen Brander start niet Verklikkerlamp stori
80. ione aria Vite di fissaggio del tubo di aspirazione aria NO A Q Il tubo di aspirazione aria 6 regolato in fabbrica V B L 01 18 Pos 4 V B L 01 22 26 30 Pos 1 Posizione 1 pressione max del ventilatore Posizione 5 pressione min del ventilatore Nei casi in cui un elevata pressione rappresentasse un fattore negativo ad esempio con notevole depressione nella camera di combustione e possibile ridurre la pressione regolando il tubo di aspirazione aria e Svitare la vite di fissaggio 7 e Impostare il tubo di aspirazione aria su un nuovo valore e Serrare di nuovo la vite FEES Er seess dana EE EE ee Te e e FF FEEFEEEES WELL PPP FF L z anam anum FEFS PEER Laur KR ENA FE EEEN FEEN FEE FEEN Z ipie FEFFIFAFPF Regolazione della pressione del gasolio La pressione del gasolio e di conseguenza la potenza del bruciatore viene regolata all interno della pompa con il regolatore 1 per il 1 stadio e regolatore 2 per il 2 stadio Per il controllo deve essere inserito un manometro in corrispondenza dell apposito attacco 6 filettatura R1 8 Controllo della depressione Il vacuometro per il controllo della depressione deve essere collegato in corrispondenza dell attacco 7 R1 8 Massima depressione ammessa 0 4 bar In caso di depressione pi elevata il gasolio gassifica con conseguente rumorosita della pompa 05 2007 Art Nr 13 022 835A Impostazione della ric
81. ircolazione Per la corretta regolazione della portata di ricircolazione necessario collegare un apparecchio di misura delle emissioni di NO e di CO Spostando il miscelatore in direzione assiale nel boccaglio del bruciatore si regola l apertura di ricircolazione Il posizionamento si ottiene tramite la vite di regolazione 3 in base al valore indicato nella tabella dei dati di impostazione Questo valore pu essere letto sulla scala 4 Dopo aver regolato la ricircolazione attendere circa 5 minuti quindi fare un nuovo tentativo di avviamento Se il bruciatore non si avvia o si avvia in ritardo regolare la ricircolazione su valori di scala pi bassi fino a ottenere un avviamento sicuro avviamento a freddo Non utilizzare il bruciatore con apertura di ricircolazione troppo socchiusa o addirittura chiusa Ne conseguirebbe un eccessivo aumento di temperatura nel miscelatore con il rischio di danneggiarlo Servomotore Y10 Tre camme rosse regolabili Tacche di posizione delle camme riferite alla scala 4 Vite di fissaggio delle camme due scale 0 18 Indice di posizione della serranda aria Connettore estraibile Nessuna funzione Pilotaggio elettrovalvola 2 stadio Posizione serranda aria 1 stadio Posizione serranda aria 2 stadio Sul lato mandata l aria viene regolata tramite un apposita serranda Questa viene azionata tramite il servomotore Y10 La posizione della serranda aria viene fissata regolando le camm
82. is de vorstberschermings functie en de beschermingsfunctie voor de zonne installatie niet gegarandeerd 17 Schoonmaken van de ketel Deksel omkasting afnemen Het deksel van de omkasting 1 naar boven opheffen Frontpanelen van de ketel afnemen Frontpanelen 2 eerst naar voren trekken en vervolgens naar boven opheffen zodat ze los komen v de bevestigingsbouten Voor onderhouds en reinigingswerk zaamheden aan de warmtewisselaar van de verbrandingsgassen en de ver brandingskamer moet de brandereen heid 3 van de ketel worden gedemonteerd Alleen geschoolde verwarmings specialisten mogen service werkzaamheden aan de ketel en aan de brander uitvoeren Het is aangeraden om aan de eigenaar van de installatie een servicecontract aan te bieden zodat gegarandeerd kan worden dat de servicewerk zaamheden op regelmatige tijd stippen worden uitgevoerd V r er onderhouds en reinigings werkzaamheden worden uitgevoerd moet de stroom worden uitge schakeld Bij onderhouds en service werkzaamheden aan de brander moet de afzonderlijke handleiding van de brander worden geraad pleegd Reiniging van de warmtewisselaar van de verbrandingsgassen Bijreiniging met water moet de stekker uit het stopcontact worden gehaald De bevestigingsschroeven 4 van het deksel 5 van de warmtewisselaar van de verbrandingsgassen verwijderen Regelaars voor de uitlaatgassen 7 uit de buizen van de
83. k met schroefdeksel 11 Bochtstuk 30 Aansluiting op de schoorsteen Aansluiting ketel met meetopening Bochtstuk 87 Buis 1 0 m Buis 0 5 m Steungeleider Steunboog 87 5 3 stuks buis met verbindingsmof 1 95 meter 1 stuk buis met verbindingsmof 1 00 meter Afstandhouder Afdekking schoorsteen schacht met bevestiging Controlestuk met schroefdeksel Bochtstuk 30 T stuk met deksel 87 5 Muurblindering D125 wit N O QO A N gt si tai a fd Og qug EH Aansluiting ketel met meetopening Bochtstuk AZ 87 Buis 1 0 m T stuk met deksel 87 5 Muurblindering D125 wit Adapter AZ AW Bochtstuk AW 87 Luchtaanzuigstuk AZ AW Controlestuk recht AZ AW Buis AZ AW 1 95 meter Instelbare muurbeugel DN 125 Verbindingsmof AZ AW Universele dakpannen voor schuin dak voor doorsteek door het dak Doorsteek door het dak AZ met windkap Bochtstuk 45 AZ AW Buis AZ AW 0 5 meter Afsluiting boven AZ AW Montage Aansluiting op de schoorsteen Afhankelijk van de lucht in de stookruimte B23 Aansluiting verbrandingsgassen op de installatie voor de verbrandingsgassen Toepassingsmogelijkheden onderdruk overdruk Installatie in de kelder Luchttoevoer via de ruimte waarin de installatie staat opgesteld Afvoer van de verbrandingsgassen via het dak Afvoer verbrandingsgassen Systeem voor luchttoevoer en verbrandingsgassen Voor de uitvoering van de installatie voor de verbrandin
84. kW Temperatuur van de verbrandings gassen De STRATON mazoutketel is met echte condensatietechniek uitgerust dankzij de afkoeling van de ver brandingsgassen via de retourleiding voor het verwarmingswater De STRATON is een mazoutketel waarvan de verbrandingsgassen in de nageschakelde condensator de restwarmte aan het verwarmingswater afgeven De condensatie begint zodra de temperatuur in de retourleiding onder de 45 C zakt Deze techniek wordt al toegepast bij stookketels op gas De condensatie zet zich ook in de buis voor de verbrandingsgassen voort wanneer de luchtaanzuiging concentrisch aangesloten is De verbrandingslucht moet slechts een kleine hoeveelheid energie opnemen aangezien een groot deel van de latente warmte van de condensator wordt gerecupereerd Bij een leiding voor de verbrandings gassen die meerdere meters lang is kan de temperatuur van de ver brandingsgassen heel dicht in de buurt van de luchtaanzuigtemperatuur komen Er wordt een nuttig effect van maximum 103 5 op Hu gehaald Wanneer de temperatuur van de verbrandingsgassen boven 60 C stijgt is dit een gevolg van het feit dat niet de volledige stroom van de ver brandingsgassen met de wanden van de warmtewisselaar in contact komt De hoeveelheid condensaat ligt bij een systeemtemperatuur van 40 30 en een nominaal warmtevermogen van 24 kW bij ca 1 45 liter uur 15 Instelling Drukverlies Doorstroomweerstand Drukverlies dru
85. khoogte STRATON 17 21 26 en 30 met mengcircuit DN25 3 weg menger Berekeningsvoorbeeld bij 1 x mengcircuit MK DN25 3W menger 4 STRATON 17 21 26 en 30 Grundfos UPS E 25 60 Grundfos UPS 25 40 E T O O O xX 5 x C QA x un lt gt Xx 3 L Q E 2 00 2 50 3 00 Volumestroom m h Hydraulische afstelling Voor de effici ntie van de installatie is behalve zo gering mogelijke systeem temperaturen de doorvoer van een hydraulische afstelling noodzakelijk Doorstroomweerstand aan warmwaterkant STRATON 17 21 26 30 Achtergrond Het verwarmingswater stroom volgens het principe van de geringste weerstand door het verwarmingsnet Bij niet afgestelde installaties leidt de weg van het verwarmingswater vooral door de in de buurt van de circulatiepomp liggende verwarmingselementen Ver weg liggende verwarmingselementen krijgen te weinig aanvoer Wordt hier door grotere pompen of hogere vaste insteltemperaturen verandering in aangebracht is hoger energieverbruik en stromingsgeluid het gevolg Doorstroomweerstand kPa Manier van werken Bij de hydraulische afregeling worden de weerstanden van de afzonderlijke verwarmingselementen via de retour schroefverbindingen zo op elkaar afgestemd dat zo klein mogelijke verwarmingscirculatiepompen en lage Volumestroom m h retourtemperaturen mogelijk zijn Wij bevelen het gebruik van onze zeer effici nte elekt
86. l impianto consigliabile stipulare un contratto di manutenzione Controllo della temperatura dei fumi di scarico e Verificare la temperatura dei fumi di Scarico Pulire la caldaia quando la temperatura dei fumi di scarico supera di oltre 30K il valore registrato alla messa in funzione Estrazione del bruciatore dalla flangia di collegamento e Staccare la corrente e Svitare la vite di bloccaggio 12 sulla flangia di collegamento e Staccare il bruciatore dall attacco a baionetta sollevarlo leggermente ed estrarlo dalla flangia di collegamento A Il tubo di fiamma pu essere rovente 05 2007 Art Nr 13 022 835A Posizionamento Aste ugello Rotore del ventilatore Piastra dell alloggiamento Ugello Viti di fissaggio piastra dell alloggiamento Rivelatore di fiamma 2 Vite di bloccaggio flangia di collegamento O 01 ND Posizioni di manutenzione del bruciatore Dopo aver svitato le viti 5 possibile agganciare la piastra dell apparecchio in due diverse posizioni di manutenzione Posizione 1 Per esempio per lavori di manutenzione che interessano la pompa Posizione 2 Per esempio per lavori di manutenzione che interessano il miscelatore Operazioni di manutenzione sul bruciatore Posizione di manutenzione 1 componenti che convogliano il gasolio tubi flessibili pompa condotto di mandata dell ugello e i relativi raccordi devono essere esaminati per controllarne la tenuta e
87. landa 7 poles Tere a A T e _ Neug AE Pha 29 Neue IE Tem 30 BomeSducome O O o 5 ee 05 2007 Art Nr 13 022 835A 23 Montage Montage du br leur Mode d installation du br leur Montage du br leur sur une chaudi re de type STRATON Lors de la livraison d une chaudi re de type STRATON le br leur est d j install sur la chaudi re pr t fonctionner Dans ce cas la profondeur d insertion doit tre r gl e sur 55 mm selon l chelle gradu e du tube de flamme 6 En cas d installation du br leur sur une autre chaudi re le montage doit tre r alis conform ment la description ci apr s 24 Montage du br leur La bride du br leur 3 est pourvue de trous oblongs et peut tre utilis e pour un diam tre de per age allant de 150 170 mm Ces cotes sont conformes la norme EN 226 La profondeur d insertion de la t te de combustion peut tre adapt e la g om trie de chaque foyer 2 par un simple d placement du porte tube sur le tube du br leur La profondeur d insertion demeure inchang e lors du montage et du d montage C est par le biais du porte tube 2 que le br leur est fix la bride de raccordement et donc la chaudi re Le foyer est alors scell Profondeur d insertion du br leur R gler la profondeur d insertion du br leur de sorte que le bord arriere 9 de l ouvertu
88. lten Nocke lll so ein stellen daf3 ein weicher Ubergang von Stufe 1 auf Stufe 2 gegeben ist Funktionskontrolle IRD Sonde Eine sicherheitstechnische Uberpr fung der Flammen berwachung muss sowohl bei der erstmaligen Inbetrieb nahme wie auch nach Revisionen oder l ngerem Stillstand der Anlage vorge nommen werden Anlaufversuch mit verdunkeltem Flammenw chter nach Ende der Sicherheitszeit muss der Feuerungs automat auf St rung gehen Anlauf mit belichtetem Flammenw ch ter nach 10 Sekunden Vorbel ftung muss der Feuerungsautomat auf St rung gehen Normaler Anlauf wenn Brenner in Betrieb Flammenw chter verdunkeln nach neuem Anlauf und Ende der Sicherheitszeit muss der Feuerungs automat auf St rung gehen 13 Service Wartung Servicearbeiten an Kessel und Brenner f hrt ausschlieBlich der geschulte Heizungsfachmann durch Um eine regelmaBige Durchf hrung der Servicearbeiten zu gew hrleis ten sollte dem Betreiber der Anlage der Abschluss eines Wartungsvertra ges empfohlen werden Kontrolle der Abgastemperatur e Abgastemperatur berpr fen e Kessel reinigen wenn die Abgastem peratur den Wert der Inbetriebnahme um mehr als 30 K berschreitet Brenner aus dem Anschlussflansch ziehen e Strom abschalten e Klemmschraube 12 am Anschluss flansch l sen e Brenner aus dem Bajonettverschlu drehen leicht anheben und aus dem Anschlussflansch ziehen Flammenrohr kann hei
89. ment la norme DIN 4755 et en respectant galement les dispositions locales 05 2007 Art Nr 13 022 835A conforme aux normes en vigueur Le br leur et le g n rateur de chaleur chaudi re sont reli s l un l autre par le biais d un connecteur 7 p les et d un connecteur 4 p les 2 Les c bles raccord s sur ce connecteur doivent avoir un diam tre compris entre 8 3 et 11 mm Le c ble de raccordement est conduit et prot g par la bride de raccordement Le connecteur 1 sert raccorder un dispositif de r armement distance Le c ble est conduit et prot g par la bride situ e sur la partie inf rieure de la platine II convient d utiliser un filtre avec un diam tre lt 25 um Respecter les valeurs limites des longueurs et hauteurs des conduites d aspiration telles qu elles sont expos es dans les directives Procal et dans les consignes relatives l am nagement et au dimension des installations comportant un syst me d aspiration La conduite d aspiration est men e au fond du r servoir sur 5 cm max si le r servoir est cubique et sur 10 cm max s il est cylindrique Attention Pression d amen e max la pompe 2 bar e Vide d aspiration max la pompe 0 4 bar e Avant la mise en service aspirer le fioul l aide de la pompe main et contr ler l tanch it des tubes de fioul Montage du c ble de protection des eaux option La vanne de protection des ea
90. mingscircuit Emissiecontrole schoor steenveger met zelfstandige retourschakeling bij normaal bedrijf Estrik droogfunctie Buffergeheugenmanagement Opwekblokkering Zonnewarmteondersteuning Ketelbuffering d m v vaste stof Dubbelcircuitregelaar met gescheiden instelling beide meng verwarmingscircuits Ruimtetemperatuurregeling via accessoires QAA 75 tweedraads bus of QAA 78 met radioverbinding Instelling van radiatoren of vloer verwarmingscircuits met aanpassing van de programma s Automatische verwarmingscurve aanpassing extra inschakelbaar Verwarmingsoptimalisatie met snelverwarming extra inschakelbaar Behoefte afhankelijke verwarmings uitschakeling Retourverhoging of retourregeling via multifunctionele uitgang configureerbaar Instelbare minimum en maximum vaste temperaturen Ge ntegreerde bedrijfsurenteller Thermische ontsmetting van het drinkwater extra inschakelbaar Legionellaschakeling Ketel en installtiebevriezings bescherming Ketelcorrosiebescherming met automatisch opstartsysteem 2 draad businterface voor regelaccessoires 2 branderniveaus Werkt samen met LPB Bus Ketelregeling d m v vaste stof Regelaar display Q4 TT ME Verwarmen op comfortinstelwaarde Verwarmen op reduceerinstel waarde Verwarmen op vorstbeschermings instelwaarde Proces loopt even wachten a u b Vakantiefunctie actief Brander in functie alleen olie gasketel Betrekking op de verwarmings circulatie
91. n lectrique de l appareil apres la remise en route de celui ci En cas de d faut la diode luminescente dans le bouton de r armement R est allum e en _ permanence ps ce que le d faut ait t acquitt c est dire que coffret ait t r arm Toutes les 10 secondes cette lumiere _ permanente est interrompue et le syst me met un code clignotant qui fournit des informations sur la cause du d faut Le programme de visualisation disponible en accessoire permet d acc der des informations d taill es suppl mentaires contenues dans le coffret concernant les v nements de l exploitation et des incidents Verrouillage et d verrouillage Le coffret peut tre verrouill mE en s curit au moyen du bouton de r armement R et d verrouill suppression du d faut la condition que le coffret soit sous tension Si l on appuie sur le bouton en exploitation normale ou pendant la phase de d marrage po el se met en s curit Si l on appuie sur le bouton pendant une mise en s curit on obtient le d verrouillage du coffret Avant le montage ou le d montage du FRO coffret l appareil doit tre mis hors tension Il ne faut ni ouvrir ni r parer le coffret x w 10 JA KW i cd Mae Re bas D I Y Moteur du br leur Vanne fuel Transf d allum R gulateur de temp rature Pr chauffeur R gulation Mise en route du coffret et du pr chau
92. nd ausreichend mit Wasser gef llt Umwalzpumpen sind in Betrieb Temperaturregler Druckregler Wassermangelsicherung und sonstige evtl vorhandene Sicherheits Begren zungseinrichtungen sind korrekt angeschlossen und in Betriebsfunk tion Abgaswege m ssen frei sein Neben luftvorrichtung falls vorhanden in Funktion Ausreichende Frischluftzufuhr muss gew hrleistet sein e W rmeabnahme muss vorhanden sein e Brennstofflagertanks m ssen gef llt sein Brennstofff hrende Leitungen m ssen fachgerecht montiert auf Dichtheit gepr ft und entl ftet sein e Normegerechte Messstelle zur Abgas messung muss vorhanden sein Abgasstrecke bis zur Messstelle muss dicht sein so dass Messergebnisse nicht durch Fremdluft verf lscht werden Einstellung der Leistungsstufen A Einstellbereich Stellantrieb max 170 Es ist nicht zulassig mehr als 170 17 Skaleneinheiten zwischen 1 Stufe und 2 Stufe einzustellen Obige Einstelldaten sind Grundeinstellungen Die Werkseinstelldaten sind fett umrandet Mit diesen Einstellungen kann im Normalfall der Brenner in Betrieb genommen werden berpr fen Sie in jedem Fall sorgfaltig die Einstellwerte Die angegebenen COs Werte sind einzuhalten Es k nnen anlagen bedingte Korrekturen notwendig sein G nstige Verbrennungswerte sind unter Verwendung der D sen Danfoss 60 S oder Danfoss 80 S zu erreichen vom Werk empfohlen Die dem Brenner beiliegende Einstell schabl
93. ne pouvez pas s lectionner un r glage sup rieur 170 17 unit s sur l chelle gradu e entre le 1 et le 2 2 palier Les donn es de r glage mentionn es ci dessus correspondent des r glages de base Les donn es de r glage de l appareil sont indiqu es en gras Ces ajustages permettent normalement de mettre le br leur en service Contr lez syst matiquement et avec soin les valeurs de r glage Les valeurs de CO donn es doivent tre respect es Des rectifications conditionn es par l installation peuvent s av rer n cessaires Les meilleures valeurs de combustion sont atteintes en utilisant les gicleurs Danfoss 60 S ou Danfoss 80 S recommand s par le fabricant Le gabarit de r glage qui accompagne le br leur peut tre utilis pour les fonctions suivantes R glage lectrode d allumage 2 L 01 30 aut D Falk VEER Positionnement lectrode d allumage 05 2007 Art Nr 13 022 835A Mise en service R glage de l air R glage de la pression du fioul m DA Pi Ze k E zx k Positionnement Servomoteur volet d air Vis de r glage ouverture de recirculation R glette gradu e ouverture de recirculation Aspiration de l apport d air Vis de blocage pour dispositif d aspiration de l apport d air NO A Q Le dispositif d aspiration de l apport d air 6 est r gl en usine V B L 01 18 Pos 4 V B L 01 22 26 30 Pos 1 Position 1 2 pres
94. ng brandt De menginrichting is aan de binnenkant ernstig vervuild met olie en heeft te maken met sterke cokesaanslag De brander begint te branden met een blauwe vlam maar valt dan regelmatig uit Vlam met gele slierten hoge Te kleine recirculatie Recirculatie opvoeren NO emissie Vlam bij werking mooi blauw en stabiel maar koudstart Verbrandingsautomaat Verkeerde instelling Verkeerd gedimensioneerde sproeier Verkeerde hoeveelheid verbrandingslucht Lucht in de zuigleiding niet dicht Stookruimte niet voldoende verlucht Te grote recirculatie Te grote recirculatie Aansluiting van de verbrandings automaatcontrole ontgrendelen en oorzaak van de storing vaststellen Instelmassa corrigeren Vervangen Brander opnieuw instellen Afdichten De stookruimte moet via een opening worden verlucht die niet kan worden afgesloten en die een diameter heeft van minstens 50 van alle diameters van de schoorstenen die bij de installatie horen Recirculatie een beetje verminderen Recirculatie een beetje verminderen niet mogelijk Moeilijke start opbouw van Startvertraging door te slechte ontsteking te Ontstekingselektroden bijstellen roet op de luchtsproeier grote recirculatie Recirculatie een beetje verminderen Oorzaken en het opheffen van regulateurstoringen Zie bedrijfshandleiding besturingspaneel LOGON B G2Z2 21 Oplossen van storingen Controles en onderhoud Regelmatige controles Bij de
95. ngslucht Accessoires boiler verbrandingsgassystemen neutralisatievoorziening voor bereiding condensaat pompeenheid Samen met de installatie worden er ook nog technische documenten en een borstel voor het schoonmaken van de ketel meegeleverd De pompeenheid is vooraf gemonteerd en is gebruiksklaar bekabeld Ze bestaat uit een driefasige of elektronische circulatiepomp met afsluiting en terugslagklep manometer veiligheidsklep en thermometer De pompmodules worden als afzonderlijk verpakte eenheden geleverd Frontpaneel Bedieningspaneel Brander Ketellichaam Afvoergas condensator Sokkel met instelvoetjes Verwarmingsregelaar LOGON B Overzicht Bedieningspaneel met Verwarmingsregelaar LOGON B G222 pai RESET atri MN 15 s t E esa m T ES NE EE ME s yg Pi Vor 1 d Schakelaar aan uit Infotoets Ruimtetemperatuur regelknop Verklikkerlampje storing brander Ontgrendelingstoets STB Bevestigingstoets OK Resettoets brander Regelknop max keteltemperatuur Handbediende functietoets STB storingsaanduiding Nauwkeurige veiligheid Schoorsteenveger functietoets STB Controletoets T V Positie terug toets ESC Functietoets drinkwater Functietoets verwarmingscircuit s Bedieningspaneel Bedrading Accessoires Het bedieningspaneel is als eenheid Bij het bedraden van de installatie Buitentemperatuursensor met alle bedieningselementen aan de moet men erop letten dat de QAC 34 NTC 1 kQ ketel gemonte
96. no gia collegati alla pompa gasolio del bruciatore Per evitare errori il flessibile di mandata e contrassegnato in modo diverso Il collegamento del gasolio avviene tramite un sistema monotubo con valvola di sfiato Sistemare il filtro in modo da garantire una corretta disposizione dei tubi flessibili non devono essere piegati La tubazione del gasolio deve presentare un diametro nominale DN4 In Svizzera tubazioni in poliammide DN4 DIN 16773 Sistema di alimentazione del gasolio Per garantire la sicurezza di funzionamento dell impianto necessario installare scrupolosamente il sistema di alimentazione del gasolio in conformita con la norma DIN 4755 e nel rispetto delle normative vigenti a livello locale 05 2007 Art Nr 13 022 835A calore caldaia sono collegati tra di loro da un connettore a 7 poli e un connettore a 4 poli 2 cavi collegati devono avere un diametro compreso fra 8 3 e 11mm Il cavo di collegamento viene fatto passare attraverso la relativa staffa e poi bloccato Il connettore 1 serve per collegare il comando di sbloccaggio a distanza Il cavo viene fatto passare attraverso la staffa nella parte sottostante sulla piastra dell apparecchio e poi bloccato IUtilizzare un filtro con larghezza maglie lt 25 um Valori limite per la lunghezza delle tubazioni di aspirazione e per l altezza di aspirazione secondo la direttiva locale o la direttiva sulla progettazione e il dimension
97. nserimento del trasformatore di accensione va in blocco inviando il seguente segnale Hilli Controllare la pressione del gasolio e il funzionamento della pompa il giunto il filtro e l elettrovalvola Verificare il circuito di accensione gli elettrodi e le relative impostazioni Pulire gli elettrodi Pulire e sostituire il rivelatore di fiamma Se necessario sostituire i seguenti componenti elettrodi cavo di accensione trasformatore ugello 46 05 2007 Art Nr 13 022 835A elco Ersatzteilliste Pi ces de rechange Lista ricambi Wisselstukkenlijst Spare parts list VECTRON BLUE L 01 18 DUO VECTRON BLUE L 01 22 DUO VECTRON BLUE L 01 26 DUO VECTRON BLUE L 01 30 DUO BLUE L 01 18 DUO 13 022 833 13 022 834 13 022 771 13 022 772 UJ UJ UJ r m m C C C m m m C r r je Q2 N N e O N UO UO UO C C C O O O 05 2007 Art Nr 13 022 835A 47 48 50 51 1 51 2 Il 13 14 15 169 10 20 05 2007 Art Nr 13 022 835A 24 25 2621 40 41 4 2 43 45 4 44 46 53 1 10 1 48 VSE8 cc0 EL AN HV 2006 50 67 Bezeichnung D signation Designation Denominazione Omschrivng AN Anschlussflansch BG Accessoires chaudi re Boiler accessories Accessori caldaia Bevestigingsset ketel 15022784 Isolierflanschi Joint fa ades Fage emmen J eom Joint tress Bradedsea Guarnizione treccia Dichting gevi
98. o e Fissare la flangia di collegamento 3 con le viti 4 alla caldaia e Montare il portatubo 2 sul boccaglio del bruciatore e fissarlo con la vite 1 Serrare la vite 1 con coppia di max 6Nm e Ruotare leggermente il bruciatore inserirlo nella flangia e fissarlo con la vite 5 Smontaggio e Svitare la vite 5 e Staccare il bruciatore dall attacco a baionetta ed estrarlo dalla flangia Impianto di scarico dei fumi Per evitare un eventuale rumorosit preferibile non utilizzare raccordi angolari nel collegamento della caldaia sul lato dei fumi L apertura di ricircolazione deve essere completamente libera per non ostacolare il ritorno dei fumi inoltre deve essere ben accessibile nella dub camera di combustione In nessun caso deve essere coperta da materiale isolante 39 Installazione Collegamento elettrico Collegamento del gasolio L installazione elettrica e i collegamenti devono essere eseguiti esclusivamente da tecnici qualificati e nel rispetto delle norme e direttive vigenti Collegamento elettrico e Controllare se la tensione di rete corrisponde alla tensione di esercizio prescritta di 230 V 50 Hz Protezione a fusibile del bruciatore 10A Connettore elettrico A Il bruciatore deve poter essere isolato dalla rete per mezzo di un dispositivo di sezionamento conforme alle norme in vigore Il bruciatore ed il generatore di Collegamento del gasolio I tubi flessibili del gasolio forniti a corredo so
99. one kann f r folgende Funktionen eingesetzt werden Z ndelektrodeneinstellung u EAF D LLEIS VEER Positionierung Z ndelektroden 05 2007 Art Nr 13 022 835A 11 Inbetriebnahme Luftregulierung Oldruckregulierung m DA Pi Ze g D e k Positionierung Stellmotor Luftklappe Einstellschraube Rezirkulations f fnung Regelskala Rezirkulations ffnung Ansaugluftf hrung Festellschraube zur Ansaugluftf hrung NO Q Die Ansaugluftf hrung 6 ist werkseitig eingestellt V B L 01 18 Pos 4 V B L 01 22 26 30 Pos 1 Stellung 1 2 max Gebl sedruck Stellung 5 2 min Gebl sedruck In F llen bei denen sich ein hoher Gebl sedruck als Nachteil erweist z B starker Unterdruck im Feuerraum kann durch Verstellen der Ansaugluftf hrung der Druck reduziert werden e Feststellschraube 7 l sen e Ansaugluftf hrung auf neuen Wert einstellen e Schraube wieder anziehen rrr ELFEN dai Aram am am zs GC d D ed O D r ai J dir r ar Ke e anam anum ra raana Laur KR ENA FE EEEN FEEN FEE FEEN ldruckregulierung Der Oldruck und damit die Brennerleis tung wird mit dem ldruckregler 1 f r die 1 Stufe 2 f r die 2 Stufe in der Pumpe eingestellt Zur Kontrolle muss am Manometeranschluss 6 ein Manometer angesetzt werden Gewinde R1 8 Unterdruckkontrolle Das Vakuummeter f r die Unterdruck kontrolle ist am Anschluss 7 anzu
100. ormalen Spannung l uft der Automat automatisch wieder an zwischen 9 und 13 L schen der Statisti Dee icones CE SEREN ld informiert ber die Ursachen einer St rabschal tung Die jeweils letzte Fehlerursache wird im ATEN CEB Ger t gespeichert und l t sich auch nach NT mehr als 13 Keine Auswirkung einem Spannungsausfall beim Wiedereinschal Sekunden auf den Automat ten des Ger ts rekonstruieren Im Fehlerfall leuchtet die Leuchtdiode im Entst rknopf R per manent bis der Fehler quittiert d h der Automat entst rt wird Alle 10 Sekunden wird dieses Leuchten unterbrochen und ein Blink Blink Code Information Fehlerursache E qur per die Slorreache gibt ber das als Zubeh r erh ltliche Visualisie DO Wartet auf Freigabe Vorw rmer Thermostat rungsprogramm k nnen dem Automaten weitere ausf hrliche Informationen ber Vorbel ftungs Vorz ndzeit a und St rvorg nge entnommen mu Kein Flammensignal nach der Sicherheitszeit un En etase R ver riegelt in St rung gebracht und entriegelt agam Fremdlicht w hrend Vorbel ftungs Vorz ndzeit entst rt werden sofern am Automat Netz spannung anliegt Manuelle St rabschaltung siehe auch Verriegelung Wird der Knopf im Normalbetrieb oder Anlauf unr nm i unge egeo gedr ckt so geht das Ger t in St rstellung Wird der Knopf im St rfall gedr ckt wird der T Erl uterung Automat entriegelt Kurzes Lichtsignal Vor Ein oder Ausbau des Automaten
101. pl Ensemble d flecteur Turbulator set BLUE L 01 18 BLUE L 01 22 Testa di combust Mengkop compleet 13 012 691 13 011 316 BLUE L 01 26 13 005 712 BLUE L 01 30 13 011 317 Luftd se Ogive Ogiva dell aria Luchtsproeier BLUE L 01 18 O19 13 006 069 BLUE L 01 22 022 13 006 070 BLUE L 01 26 024 13 006 071 BLUE L 01 30 926 13 006 072 Bague r glage air Adjust ring secondary air Manicotto di regolazione Doseer ring 13 005 659 secondaire ES Z ndelektr Set L R Electrode allu D G Ignition electrode L R Elettrodo di accensione Elektr ontstek L R 13011129 WU D sengest nge Ligne gicleur Nozzle assembly Stanga de ugello Sproeierlijn 13022955 531 Kabel D sengest nge C ble r chauffeur Preheater cable Cavo riscaldam Kabel voor de voorverhitter 13022956 532 Einstellskala R glette gradu e Graduated ruler Scala graduata Instelschaalverdeling 13 010 100 E Z ndkabel Set C ble allu Ignition lead Cavo di accensione Ontstekingskabel 2 x L225 2X L225 2x L225 2x L225 2X L225 2X 60 Z ndtrafo Transformateur allu Ignition transfo Trasformatore d accensione 13 009 663 23 Grundplatte Platine tanche boitier de Tight plate Set control Luftleitgeh use Set Nr 15 commande n 15 panel n 15 61 1 Mehrfachbride Bride fixation flexibles Hose fix flange Flangia multipla Slangen aansluitstuk 13011134 65 D senzuleitung Tube Po ligne gicleur Oil feed tube Tubetto pompa Buisje pomp 13 012 683
102. pr sentant les sp cifications suivantes doit tre install e CH QF kW x 6 cm mais au moins 150 cm DE jusqu 50 kW 150 cm pour chaque kW suppl 2 cm Les dispositions locales peuvent contenir des prescriptions diff rentes 05 2007 Art Nr 13 022 835A br leurs fioul air souffl Nous soci t certifi e sous le n AQF030 74106 ANNEMASSE Cedex d clarons sous notre seule responsabilit que les produits suivants VECTRON BLUE L 01 18 DUO VECTRON BLUE L 01 22 DUO VECTRON BLUE L 01 26 DUO VECTRON BLUE L 01 30 DUO sont en conformit avec les normes suivantes EN 50165 EN 55014 EN 60335 EN 60555 2 EN 60555 3 EN 267 Arr t Royal Belge du 08 01 2004 En conformit avec les dispositions des directives 89 392 CEE 89 336 CEE 73 23 CEE Directive machine Directive CEM Directive basse tension Directive coefficient de rendement 92 42 CEE Ces produits sont marqu s avec le label CE Fait Annemasse le 1er avril 2007 Nous n assumons aucune garantie pour les dommages qui r sultent des causes suivantes utilisation non conforme installation et ou remise en tat erron es par l acheteur ou par un tiers y compris la mise en place de pi ces d autres origines Remise et notice d utilisation Le constructeur de l installation de chauffage doit remettre l exploitant de l installation au plus tard lors de la remise de celle ci une notice d utilis
103. prend en charge la r gulation de la pression Le volet d air continue de fonctionner en position grand d bit le grand d bit est exploit R gulateur de pression du fioul d bit partiel 104 Vanne magn tique d bit partiel Y1 avec bypass pour le syt me de coupure de la ligne de gicleur Tambour de dosage de l air lin aris 103 05 2007 Art Nr 13 022 835A S curit Un arr t d incident intervient si pendant la pr ventilation un signal de flamme est d clench d tection de lumi re parasite si au cours du d marrage lib ration du combustible et apr s 10 secondes temps de s curit aucune flamme ne s est form e si enl absence de flamme au cours de l exploitation et apr s une tentative de red marrage infructueuse aucune flamme n apparait En cas d arr t d incident la lampe t moin de d rangement s allume il suffit d appuyer sur la touche de r armement apr s limination de la cause de la perturbation pour d bloquer le syst me Pour de plus amples informations voir le descriptif du coffret de commande et de s curit Ligne gicleur r chauff e E4 Vanne diaphragme pour la coupure de la ligne gicleur Moteur du br leur M1 Tube du br leur Tube de flamme Moteur du volet d air Y 10 Fonctionnement Coffret de s curit SH 213 C3 Appuyer sur R pendant provoque moins de 9 secondes D verrouillage ou verrouillage du
104. r Danfoss 60 80 S nt ME 0 30 Gph 60 S o 13013892 0 40 Gph 60 S o 13018343 0 45 Gph 80 S 13018350 Legende L gende Legenda Legende Caption Vi Hilfsmaterial Pi ces Materiali di Onderhoudson Maintains d entretien consumo derdelen parts Pi ces de Parti di Spare parts rechange ricambio U Verschleiss Pi ces d usure Parti di usura Slijtage Wearing teile onderdelen parts Hilfsmittel sind solche Teile die im Zuge der Wartung beim Zusammenbau demontierter Teile vorsorglich ersetzt werden sollten z B Dichtungsmaterial F r Verschlei teile und Hilfsmittel gilt die Haltbarkeitsgarantie gem den Gesch ftsbedingungen der Firma ELCO nicht Verschlei teile sind solche Teile die auch bei bestimmungsgem em Gebrauch des Gesamtproduktes im Rahmen der Lebensdauer des Produktes mehrfach ausgetauscht werden m ssen z B Old sen Olfilter F r Verschlei teile und Hilfsmittel gilt die Haltbarkeitsgarantie gem den Gesch ftsbedingungen der Firma ELCO nicht Les pi ces d entretien sont des pi ces qui devraient tre remplac es titre pr ventif au cours de l entretien lors du remontage des pi ces d mont es par exemple des l ments d tanch it Pour les pi ces d usure et les pi ces d entretien la garantie de tenue dans le temps selon les conditions commerciales de la soci t ELCO ne s applique pas Les pi ces d usure sont des pi ces qui doivent tre remplac es plu
105. re de recirculation 10 touche directement 11 l isolation de la porte de la chaudiere Fermer avec soin la porte de la chaudi re Pr ter attention au rayon de pivotement libre du tube de flamme 6 Si n cessaire retirer le br leur et r ajuster l isolation de la porte de la chaudi re Positionnement Vis de s curit porte tube Porte tube Bride de raccordement Vis bride Vis de s curit bride Tube de flamme Tube du br leur Joint ba onnette Bord arri re de l ouverture de recirculation 10 Ouverture de recirculation 11 Isolation de la porte de la chaudi re cO O O1 QO ND ch 05 2007 Art Nr 13 022 835A Montage e Fixer la bride de raccordement 3 la chaudi re au moyen des vis 4 e Monter le porte tube 2 sur le tube du br leur et le fixer avec la vis 1 Serrer la vis 1 avec une torsion de 6 Nm max e Tourner doucement le br leur l introduire dans la bride et fixer le tout l aide de la vis 5 D montage Desserrer la vis 5 e Tourner le br leur pour l ter du joint ba onnette puis l extraire de la bride Systeme pour les gaz de combustion Pour viter toute mission sonore d sagr able il convient de renoncer aux pi ces de raccordement angles droits pour le rattachement de la chaudi re c t gaz br l s L ouverture de recirculation ne doit surtout pas tre obstru et doit tre facilement accessible dans le foyer pour permettre le recyclage des
106. retta preimpostazione del bruciatore secondo i dati specificati nella tabella Impostazione del miscelatore deve essere inserito l ugello giusto Il generatore di calore deve essere montato pronto per l uso e devono essere osservate le relative norme di funzionamento Valori di impostazione di base Velo Distanza Sai di Apertura Posizione Ugello l un ugello l Bruciatore HE gasolio ricircola ale guide 60 S zione 9 Danfoss mm mm Tutti i collegamenti elettrici devono essere stati eseguiti correttamente II generatore di calore e il sistema di riscaldamento devono essere sufficientemente riforniti di acqua le pompe di circolazione sono in funzione Il regolatore di temperatura i regolatori di pressione la protezione basso livello acqua e gli eventuali altri dispositivi di sicurezza presenti sono correttamente collegati e in funzione condotti di scarico dei fumi devono essere liberi e il dispositivo aria secondaria se presente deve essere in funzione Stadion O e 2 8 bruciatore potenza Campo di regolazione dell attuatore max 170 Non ammesso impostare oltre 170 17 unit sulla scala tra il 1 e il 2 stadio dati di cui sopra rappresentano le impostazioni di base dati di impostazione di fabbrica sono evidenziati in grassetto In condizioni normali il bruciatore pu essere messo in funzione con queste impostazioni Pressione Deve essere garantita una sufficiente alimentazione di
107. ronisch geregelde verwarmingscirculatiepompen aan 04 05 06 0 7 08 0 9 1 0 Indienststelling Controlemaatregelen Controles voor de indienststelling Alle installaties voor de olieleiding en de elektrische installaties moeten klaar zijn v r de volledige installatie in dienst wordt gesteld V r de indienststelling moeten de volgende controles worden uitgevoerd waterdruk in het verwarmings circuit bedrijfsklare toestand van de circulatiepomp controleren of het mengorgaan open staat handmatige bediening nagaan of de stroomvoorziening naar de ketel gewaarborgd is 230 V 50 Hz controle van de leiding voor de verbrandingsgassen controle van het oliepeil in de olietank controle of de olieleiding correct is geinstalleerd en of de regle menten bij de inbouw werden gerespecteerd controle of de olieslangen toevoer en terugvoer niet werden verwisseld en of de aansluitingen dichtgeschroefd zijn alle afsluiters in de olieleiding open zetten de volledige zuigleiding met olie vullen handpomp controle van de sterkte van de zekering en controle van de spanning aan de brander thermostaatschuif De oliepomp mag nooit droog d w z zonder olie worden bediend Daarom moet de zuigleiding v r het inschakelen met olie gevuld zijn De pomp wordt uiteindelijk ontlucht door de overeenkomstige dop aan de pomp te openen Dit moet ook gebeuren na een lange periode van stilstand van de ins
108. sal va el zal ul N nl SCX SIX les 1 N I e90 pel e uoo peplwIOJUOI ua EAN e ejseng T T jeu yfijesyeejd jou jaw Guiuuue1sueaJa o ui Buipiev p z veg Z oO 8191 eje EIWIOJUOD UI Ella e essan u Ka p CA LO D SS uollg n6 4 eso Um eouepJoooe ui Buyer 4s Zd Ld CO 9H l oe LJ epi L e90 NE9S91 ne jueulguu0jJuoo 9419 e e esi A e U 1JHUOSJOA u u2ol uo uoeu BuNpIJ S E o nbojqs q OlEJOU 10pejuo Ole sedejo z Jopeju nolu liuuelu eS5 iqos ep JOPpe WI ZHOS A OEE 19S9H Je eunf Buiio1lS den z eelsouusulsBunu d g Jee jsowau Pulping oidiouug ep euienbs3 0990 qS SIOEJUOI 9O9juaiueAuoou IPEIS Z 9J0 e1luJI eZZ9Jnois Ip opejsouua euleuosediouug s y Joao sunou buiuuny o qnoJ L soDels z JQUWIT Jonwij eS o peJouoD euiau9s sumeret d eDe inoueAoq oJreJou In lduuoo ouueg soJn e z JnojurT o1unoos ep d uj weibeip noo DISEE Buipaon auser BunjeBauueuis4 jejuezuepunissqeuieg BuUNJOIS BMS Z Jezuelbeg JezueJDeqsiieuJ8uoiS ediouud ep euiguog eouneje euoizejueulllv ss lt d Ld 9H LS 9S LA Bunyjeis epdrzuud A ddns somod uonejueuuiv seuoiodo endo euoizdo suondo suondo ueuondo EJSP EI 919M etepje9 Je log eYeipneu JesseM Dunsiedsur3 po uu oom dox Y a C C oDeg G8E0 LO EWUIUIS ID N q 6978L0 1I oN HV ZIN ESIA 90 CE 70 SIET 6890L JOPEZUBAINd Je101dS oren 9 ZZON IDDIE osng 9LL
109. schlie en R1 8 H chstzul ssiger Unterdruck 0 4bar Bei h herem Unter druck vergast das Heiz l wodurch kratzende Ger usche in der Pumpe entstehen 05 2007 Art Nr 13 022 835A Einstellung der Rezirkulation Zur korrekten Einstellung der Rezirkula tionsmenge ist ein NO und CO Messger t anzuschlie en Durch axiale Verschiebung der Misch einrichtung im Brennerrohr wird die Breite der Rezirkulations ffnung einge stellt Die Positionierung erfolgt an der Einstellschraube 3 entsprechend dem in der Tabelle Einstelldaten angegebenem Wert Dieser Wert kann an der Skala 4 abgelesen werden Nach Einregulierung der Rezirkulation sollte nach einer Betriebspause von ca 5 Minuten ein erneuter Startversuch vorgenommen werden Startet der Brenner nicht oder versp tet ist die Rezirkulation auf kleinere Skalenwerte einzustellen bis ein sicherer Start gew hrleistet ist Kaltstart Brenner nicht mit viel zu geringer oder geschlossener Rezirkulations ffnung betreiben Starker Tempera turanstieg in der Mischeinrichtung w re die Folge und k nnte zur Besch digung der Mischeinrichtung f hren Stellmotor Y10 1 drei verstellbare rote Nocken 2 Markierung der Nockenstellung bezogen auf die Skalen 4 S Stellschraube der Nocken 4 zwei Skalen 0 18 5 Zeiger der Luftklappenstellung 6 Abziehbarer Steckverbinder Il keine Funktion I Ansteuerung Magnetventil 2 Stufe IV Luftklappenstellung 1 Stufe V Luftklappenstell
110. sieurs reprises au cours de la dur e de vie du produit m me dans le cas d une utilisation du produit global conforme sa destination par exemple les injecteurs d huile les filtres d huile Pour les pieces d usure et les pieces d entretien la garantie de tenue dans le temps selon les conditions commerciales de la soci t ELCO ne s applique pas materiali di consumo sono i particolari che in sede di manutenzione devono essere sostituiti per precau zione al rimontaggio delle parti ad esempio il materiale di tenuta Ai sensi delle condizioni generali della ditta ELCO per le parti di usura e i materiali di consumo non si applica la garanzia di durata Le parti di usura sono i particolari che durante la vita utile del prodotto devono essere sostituite pi volte anche in condizioni di utilizzo regolarmentare del prodotto ad esempio ugelli del gasolio e filtro del gasolio Ai sensi delle condizioni generali della ditta ELCO per le parti di usura e i materiali di consumo non si applica la garanzia di durata Onderhoudsonderdelen zijn onderdelen die horen te worden vervangen als preventieve maatregel bij onderhoudsbeurten telkens wanneer onderdelen worden gedemonteerd bijvoorbeeld afdichtingselementen Voor slijtage en onderhoudsonderdelen is de garantie van levensduur volgens de handelsvoorwaarden van ELCO niet van kracht Slijtage onderdelen zijn onderdelen die meermaals gedurende de levensduur van het product moeten worden vervang
111. sion de ventilation max Position 5 pression de ventilation min Dans les cas o une pression de ventilation lev e se r v le tre un inconv nient par exemple en cas de d pression forte dans le foyer la pression peut tre r duite en ajustant le dispositif d aspiration de l apport d air Desserrer la vis de blocage 7 H gler le dispositif d aspiration de l apport d air sur la nouvelle valeur e Resserrer la vis PPE p FE FF FRE Z L Ll L A E FF FES FESSES FFF FEEL EE EES E TE EFFETS PITIITITE es PPP VPFFFFWFi PETE 2 i FES rr Sa rr Sa rr gt FEEN Fir CA tweet ege ur Reglage de la pression du fioul La pression du fioul et par cons quent la puissance du br leur s ajuste au moyen du r gulateur de Dm du fioul 1 pour le 1 palier 2 et dans la pompe pour le 2 palier Pour assurer le contr le un manometre doit tre ajout au raccordement 6 pr vu cet effet filetage R1 8 Contr le de la d pression Un vacuometre doit tre 7 raccord pour permettre le contr le de la d pression H1 8 D pression maximale autoris e 0 4 bar Lorsque la d pression est plus lev e le fioul domestique se gaz ifie ce qui provoque des gr sillements dans la pompe 05 2007 Art Nr 13 022 835A Ajustage de la recirculation Un appareil de mesure NO et CO doit tre raccord pour obtenir un r glage correct du volume de recirculation La largeur de l ouverture de recirculation
112. tallatie Indienststelling brander De eerste indienststelling van de brander mag uitsluitend door gespecialiseerde vakmensen worden uitgevoerd Daarbij wordt het gewenste vermogen van de ketel ingesteld worden ver brandings en emissiemetingen uitgevoerd en wordt nagegaan of de thermostaten en de veiligheids voorziening correct functioneren Indienststelling regeling De eerste indienststelling van de regeling mag uitsluitend door gespecialiseerde vakmensen worden uitgevoerd Daarbij worden de ideale waarden de schakeltijden en de standaardprogramma s naar gelang van de wensen van de klant ingesteld In ieder geval moeten ook de dag van de week en het uur worden ingesteld Uitschakelen van de installatie Schakelaar voor de brander uitschakelen Olietoevoer uitschakelen Installatie niet leegmaken Toets Standby op de regelunit indrukken bescherming tegen bevriezen is gegarandeerd De verwarming valt in de zomer automatisch uit op de stand Auto in het geval van bedieningspanelen met een ingebouwd regelapparaat Als er tijdens de periode dat de installatie uitgeschakeld is vorstgevaar dreigt is het beter om het water uit de ketel en de ver warmingsinstallatie te verwijderen en ook de stroomtoevoer naar de installatie uit te schakelen Opgelet Tijdens de zomer mag de ver warmingsketel uitsluitend via de standby toets worden uitgeschakeld Bij het uitschakelen via de AAN UIT Schakelaar
113. ter le filtre e Nettoyer remplacer avec soin e Remettre le filtre 11 en place e Contr ler remplacer le joint e Monter le filtre Nettoyer le filtre du tube de fioul Fermer le robinet d arr t du filtre e Nettoyer remplacer la piece filtrante e Utiliser une pi ce filtrante avec un diam tre lt 25 um Lors de l ouverture du robinet d arr t v rifier l tanch it du syst me filtrant Montage de la roue de ventilateur Veuillez observer les instructions du sch ma de positionnement ci contre lors du remplacement du moteur et de la roue de ventilateur La bride int rieure A de la roue de ventilateur doit tre fix e la partie sup rieure du coffret B Ins rer un guide entre les ailettes de la roue de ventilateur et faire en sorte que A et B se trouvent la m me hauteur serrer la tige filet e de la roue de ventilateur 05 2007 Art Nr 13 022 835A Maintenance Elimination des d fauts Causes et limination des d fauts Lors d une panne contr ler les conditions pr alables un fonctionnement normal 1 Y a t il du courant lectrique 2 Y a t il du fuel dans la citerne 3 Est ce que tous les robinets d arr t sont ouverts 4 Est ce que tous les appareils de r gulation et de s curit comme le thermostat de la chaudi re le dispositif de protection contre le manque d eau les interrupteurs de fin de course etc sont r gl s correctement Constats Apr s une co
114. tomaten Klemme C des Automaten 2 des SM St Klemme 7 des Automaten Klemme T1 am Wiel St 7P 2 des SM St Neutral 34 Klemme B5 am Wiel St 4P 4 des SM St und Phase der Ventil 2 Klemme 5 des Automaten Klemme B4 am Wiel St 7P 5 des SM St und Phase der Ventil 1 Klemme 5 des Automaten 10 11 12 15 Erde 1 1 1 1 36 Neutral 6 des SM St Neutral Klemme 3 des Automaten 7 des SM St Klemme 4 des Automaten 38 Klemme 6 des Automaten 8 des SM St wenn Br cke zwischen 4 und 6 oder wenn Heizung warm ist dann Klemme 4 und 6 Erde 39 Klemme B des Automaten durch Klemmen T6 und T8 am Wiel St 4P 9 des SM St T8 Newa 40 Phase S 15 Klemme T des Automaten ES GC 16 Klemme 2 des Automaten Neutral 16 17 Klemme 9 des Automaten Klemme 5 des Automaten Ventil 18 Klemme B5 am Wiel St 4P Und Klemme 4 des SM St Klemme 6 des Automaten Heizung 19 20 22 23 24 25 26 Ede Kemme4des Automaten Heizungskontakt Neutral Erde Klemme 5 des Automaten und Klemme B4 am Wiel St 7P 47 Neutral Z hler 1 St Klemme B5 am Wiel St 4P und Klemme 4 des SM St 48 Klemme T8 am Wiel St 4P Z hler 2 St Klemme T6 am Wiel St 4P Klemme T7 am Wiel St 4P Klemme T2 am Wiel 8t 7P E eee a_i 05 2007 Art Nr 13 022 835A Montage Brennermontage Brenner Einbausituation Brennermontage an Kesseltyp STRATON Bei Lieferung eines Kessels des Typs ST
115. ubinetto di intercettazione sul filtro e Pulire accuratamente o sostituire l elemento filtrante e Utilizzare un elemento filtrante con larghezza maglie 25 um e All apertura del rubinetto di intercettazione controllare la tenuta dell impianto di filtrazione Montaggio del rotore del ventilatore Quando si procedere alla sostituzione del motore e del rotore del ventilatore osservare lo schema di posizionamento a lato La flangia interna A del rotore deve essere portata all altezza della piastra dell alloggiamento B Inserire un righello tra le pale del rotore del ventilatore e portare A e B alla stessa altezza quindi serrare il perno filettato sul rotore del ventilatore 05 2007 Art Nr 13 022 835A 45 Assistenza Eliminazione dei guasti Cause ed eliminazione dei guasti In caso di guasto necessario controllare le premesse essenziali per un funzionamento regolare 1 L alimentazione elettrica presente 2 C gasolio nel serbatoio 3 Sono aperti tutti i rubinetti di intercettazione 4 Sono stati impostati tutti gli apparecchi di regolazione e di sicurezza quali il termostato della caldaia la protezione basso livello acqua l interruttore di finecorsa ecc Se con il controllo dei punti elencati non e stato possibile eliminare il guasto controllare il funzionamento dei singoli componenti del bruciatore Osservare il codice lampeggiante visualizzato del programmatore e rilevarne il sign
116. ung 2 Stufe Die druckseitige Luftregulierung erfolgt ber eine Luftklappe Diese wird ber Stellmotor Y10 angetrieben Die Position der Luftklappe wird durch Einstellung der Nocken IV V festgelegt Zur Verstellung dienen die Schrauben S Rechts drehen mehr Luft Links drehen weniger Luft A Einstellbereich Stellantrieb es ist nicht zulassig mehr als 170 17 Skaleneinheiten zwischen 1 und 2 Stufe einzustellen Inbetriebnahme Einregulierung des Brenners Brenner starten Vor Start des Brenners Ol mit Handpumpe ansaugen bis Filter voll st ndig gef llt ist Anschliefend Brenner durch Einschal ten des Kesselreglers starten Zur voll st ndigen Entl ftung der Olleitung w hrend der Vorbel ftungsphase Ent l ftungsschraube am Olfilter ffnen Hierbei darf ein Unterdruck von 0 4bar nicht unterschritten werden Wenn bla senfreies Ol kommt und Filter ganz mit Ol gef llt ist Entl ftungsschraube schlie en Einstellung Stufe 1 Nocke IV e Stecker 4 polig ausstecken Brenner f hrt auf Stufe 1 _ Uber Druckregler 1 Oldruck f r Stufe 1 entsprechend gew nschter Bren nerleistung einstellen Hierbei st ndig die Verbrennungswerte kontrollieren CO CO Falls erforderlich Luftmenge anpassen ggf schritt weise vorgehen Luftmenge erh hen Nocke IV auf h heren Skalenwert stellen Stecker 4 polig kurzzeitig ein und ausstecken Luftklappenmotor nimmt die neue Kleinlastposition ein
117. unzione e la manutenzione devono essere eseguiti esclusivamente da personale specializzato autorizzato e nel rispetto delle direttive e norme applicabili Sono soddisfatti i requisiti fissati nella normativa 1 BlmSchV corrente e nell ordinanza LRV Alle condizioni di prova fissate dalla norma EN 267 i valori di emissioni di NOx sono risultati 120mg kWh A seconda della configurazione geometrica della camera di combustione del carico e del sistema di combustione caldaia a tre passaggi caldaia a fiamma inversa possono registrarsi valori di emissione diversi Per i valori di garanzia attenersi alle condizioni inerenti gli apparecchi di misura le tolleranze l umidit dell aria e il tenore di azoto nel gasolio Descrizione del bruciatore bruciatori VECTRON BLUE L 01 18 22 26 30 DUO sono bruciatori bistadio a funzionamento completamente automatico in esecuzione monoblocco Sono idonei per tutti i generatori di calore conformi 32 alla norma EN 303 nel relativo campo di potenza La speciale configurazione della testa di combustione con ricircolazione interna dei fumi di scarico consente un rendimento maggiore della combustione e al contempo basse emissioni di ossido di azoto Per un funzionamento sicuro ecologico ed economico necessario osservare le seguenti norme EN 226 Collegamento di bruciatori d olio a nebulizzazione e bruciatori di gas con ventilatore a generatori di calore EN 60335 2 Sicurezza degli app
118. upure thermostatique le br leur ne d marre plus Le coffret ne signale aucun d faut Lorsqu on le met en route le br leur d marre pendant une p riode tr s br ve ensuite il s arr te et met le signal suivant Apres une coupure thermostatique le br leur ne red marre plus et met le signal suivant Le br leur d marre et peu de temps apr s la mise en route du transformateur d allumage il se met en s curit et affiche le signal suivant S il n est pas possible de rem dier au d faut apr s avoir contr l les points indiqu s ci dessus il faut v rifier les diff rentes fonctions qui se rattachent aux composants du br leur e Tenir compte des signaux lumineux mis par le coffret de commande et de s curit et retrouver leur signification dans le tableau ci dessous Le programme de visualisation disponible en accessoire permet d acc der des informations d taill es suppl mentaires contenues dans le coffret concernant les v nements de l exploitation et les d fauts Causes Baisse ou d faillance de la tension d alimentation lectrique Pas de demande de chaleur par le thermostat D faut au niveau du coffret Le coffret avait t verrouill volontairement Flamme parasite en pr ventilation ou en pr allumage Absence de flamme la fin du temps de s curit 05 2007 Art Nr 13 022 835A Les composants de s curit ne peuvent pas tre r par s mais doivent
119. usssystem Teillast Y1 linearisierte Luftdosiertrommel 103 D senstange beheizt E4 Membranventil f r D senabschluss 05 2007 Art Nr 13 022 835A Sicherheitsfunktion Eine St rabschaltung erfolgt wenn w hrend der Vorbel ftung ein Flammensignal vorhanden ist Fremdlicht berwachung wenn beim Start Brennstofffreigabe nach 10s Sicherheitszeit keine Flammenbildung erfolgt ist wenn bei Flammenausfall w hrend des Betriebes nach erfolglosen Wie deranlaufversuch keine Flamme entsteht Eine St rabschaltung wird durch Aufleuchten der St rlampe angezeigt und kann nach Beseitigung der St r ursache durch Dr cken des Entst r knopfes wieder entriegelt werden F r weitere Informationen siehe Beschreibung Feuerungsautomat 10 Brennermotor M1 12 Brennerrohr 13 Flammenrohr 14 El Luftklappenantrieb Y10 Funktion Feuerungsautomat SH 213 C3 Der Olfeuerungsautomat SH 213 C3 steuert und berwacht den Gebl sebrenner Durch den Dr cken Sie auf R f hrt zu Mikroprozessor gesteuerten Programmablauf w hrend ergeben sich u erst stabile Zeiten unabh n gig von Schwankungen der Netzspannung oder der Umgebungstemperatur Der Feuerungs automat ist unterspannungssicher ausgelegt Weniger als 9 Entriegelung oder Wenn die Netzspannung unter dem geforderten Sekunden Verriegelung des Mindestwert liegt schaltet der Automat ohne Automaten ein Fehlersignal ab Nach Wiedererreichen einer n
120. utomat ersetzen Automat wieder entriegeln Magnetventil ersetzen lstand im Tank kontrollieren Tank ggf auff llen Ventile ffnen ldruck und Betrieb der Pumpe Kupplung Filter Magnetventil kontrollieren Z ndkreis Elektroden und ihre Einstellungen pr fen Elektroden reinigen Flammenw chter reinigen und ersetzen Wenn n tig folgende Teile ersetzen Elektroden Z ndkabel Trafo D se Informations g n rales Sommaire Page Informations g n rales Indications importantes 17 Caract ristiques techniques 18 Courbes de puissance 18 Dimensions description du br leur 19 Fonctionnement Pr chauffage exploitation s curit 20 Coffret de commande et de s curit 21 Pompe fioul accessoires de raccordement 22 Plan d affectation socle de raccordement 23 Montage Montage du br leur 24 Mode d installation du br leur 24 Raccordement lectrique 25 Raccordement du fioul 25 Mise en service Contr les avant la mise en service 26 Donn es de r glage
121. ux est raccord e via un c ble conduit s par ment elle est galement conduite et prot g e par la bride situ e sur la partie inf rieure de la platine e D monter le c ble de raccordement du moteur du br leur 3 e Brancher la fiche interm diaire 4 sur le moteur du br leur e Ins rer le c ble de raccordement du moteur du br leur dans la prise 5 e Effectuer le raccordement de la contre prise de la vanne de protection des eaux des incendies 6 sur la vanne de orotection des eaux des incendies S assurer du bon fonctionnement du systeme 25 Mise en service Controles avant la mise en service Donn es de r glage Contr le de la t te de combustion Contr les avant la mise en service e Tous les raccordements lectriques doivent Une arriv e d air frais suffisante doit tre Avant la toute premi re mise en service tre effectu s dans les r gles de l art garantie chacun des points suivants doit faire l objet Le g n rateur de chaleur et le syst me de Un dispositif de r duction de la chaleur doit d une v rification minutieuse chauffage doivent tre suffisamment tre install Montage correct du br leur conform ment remplis d eau les pompes de recirculation Les bacs de stockage du combustible aux instructions fournies dans le pr sent sont en fonctionnement doivent tre pleins manuel Ler gulateur de temp rature le r gulateur Les conduites d acheminement du Pr s lection corre
122. van het oliefilter in de olietoevoerleiding Montage van de schoongemaakte onderdelen en nieuwe indien ststelling van de brander Controle van de werking van de vlammenbewaking Instelling op de optimale werkingsgraad Metingen van de verbrandings gassen Schoonmaken en opnieuw vullen van de neutralisatiebox Opgelet De neutralisatiebox indien die voorhanden is moet n keer per jaar worden gecontroleerd Deze controle wordt door erkende vaklui uitgevoerd Wij adviseren u om aan de klant een onderhoudscontract aan te bieden Notities 23 Service ELCO GmbH D 64546 M rfelden Walldorf ELCO Austria GmbH A 2544 Leobersdorf ELCOTHERM AG CH 7324 Vilters ELCO Rendamax B V NL 1410 AB Naarden ELCO Belgium n v s a B 1731 Zellik ELCO Italia S p A 31023 Resana elco VECTRON BLUE L 01 18 DUO VECTRON BLUE L 01 22 DUO VECTRON BLUE L 01 26 DUO VECTRON BLUE L 01 30 DUO Betriebsanleitung F r die autorisierte Fachkraft Ol Gebl sebrennetr 2 16 Notice d emploi Pour l installateur sp cialiste Br leurs fuel 17 31 Istruzione per l uso Per il personale qualificato Bruciatori a gasolio Ersatzteilliste Pieces de rechange Lista ricambi Wisselstukkenlijst Spare parts list 47 52 Elektro und Hydraulikschema Sch mas le
123. voorschriften OVE voorschriften en de plaatselijke voorschriften Art 15a BVG Beroepspreventiewet volgens verwarmingsinstallatie verordening vo FAV 97 Zwitserland In Zwitserland moet met de volgende wettelijke voorschriften rekening worden gehouden LRV 92 verordening tegen luchtverontreiniging milieuwet wet tegen waterverontreiniging verordening tegen water verontreiniging aanbeveling voor de afvoer van water uit condensatie verwarmingsketels SVGW principes voor gas SVOW principes voor water aanbeveling in verband met de minimum hoogte van schoorstenen VKF brandpreventierichtlijnen SWKI richtlijnen voorschriften van SEV en ESTI Overzicht Productbeschrijving Productbeschrijving De STRATON mazoutketel is geschikt voor lage temperatuurverwarmingen en de bereiding van warm water in verwarmingsinstallaties met toevoertemperaturen tot 80 C en 3 bar toegelaten bedrijfsoverdruk De STRATON mazoutketel is een voorgefabriceerde eenheid die uit de volgende componenten bestaat Stalen verwarmingsketel met aangesloten condensator uit edelstaal voor de verbrandingsgassen Het ketellichaam is rondom met nauw aansluitend warmtebehoudend isolatiemateriaal omgeven Vlakken die niet met water gekoeld worden zijn voorzien van hoogwaardig keramisch isolatiemateriaal Ingebouwde geblazen mazoutbrander met recirculatie tweefasig met voorverwarming van de stookolie el
124. w chter siehe Seite 13 durchf hren Service Wartung Positionierungen 7 8 9 10 11 A B Luftd se Befestigungsschrauben Luftd se Z ndelektrode Befestigungsschraube Z ndelektrode Filter Innenflansch Ventilatorrad Geh useplatte Innenseite Pumpenfilter reinigen Filter herausnehmen vorsichtig reinigen austauschen Filter 11 wieder einsetzen Dichtung kontrollieren austauschen Filter montieren lleitungsfilter reinigen e Absperrhahn am Filter schlieBen Filtereinsatz reinigen austauschen Filtereinsatz mit Maschenweite lt 25ym verwenden e Beim Offnen des Absperrhahnes die Filteranlage auf Dichtheit pr fen Montage des Ventilatorrades Bei Motor und Ventilatorradaustausch nebenstehendes Positionierungs schema beachten Der Innenflansch A des Ventilatorrades muss auf der H he der Geh useplatte B angebracht werden Ein Lineal zwischen die Fl gel des Ventilatorrades einf hren und A und B auf die gleiche H he bringen Gewin destift am Ventilatorrad anziehen 05 2007 Art Nr 13 022 835A 15 Service Storungsbeseitigung Ursachen und Beseitigung von St rungen Bei St rungen m ssen die grunds tzli chen Voraussetzungen zum ordnungs u Betrieb kontrolliert werden Ist Strom vorhanden Ist l im Tank Sind alle Absperrh hne ge ffnet Sind alle Regel und Sicherheits ger te wie Kesselthermostat Wassermangelsicherung End schalter etc eingestellt
Download Pdf Manuals
Related Search
Related Contents
EQ3 Bedienungsanleitung (Teleskope mit MEQ3 Anexo 3 - Instrucoes de Controle User manual for G20E GSM Alarm with LCD Owner`s Manual Model TG32P12 セイバー 超小旋回ミニショベル Brother 888-X56 Sewing Machine User Manual 20024 man_GB - pedranti elio Manuel d`utilisation - Sécurité sociale.be Holux GM-82 User's Manual Copyright © All rights reserved.